Loading...
HomeMy WebLinkAboutPermit PG08-162 - CHASING FIREFLIESC SING FIREFLIES 350 MIDLAND DR PGO8-162 Parcel No.: 8836500100 Address: Suite No: Cityif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 350 MIDLAND DR TUKW PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: PG08 -162 06/23/2008 12/20/2008 Tenant: Name: CHASING FIREFLIES Address: 350 MIDLAND DR , TUKWILA WA Owner: Name: AMB PROPERTY CORP /ATTN: REA Address: 60 STATE ST STE 1200 , BOSTON MA Contact Person: Name: FRED LANGFORD Address: 21004 NE 115 ST , REDMOND WA Contractor: Name: LANGFORD PLUMBING INC Address: 21004 NE 115 ST , REDMOND WA Contractor License No: LANGFPI *044R8 Phone: Phone: 206 465 -6240 Phone: 206 - 465 -6240 Expiration Date: DESCRIPTION OF WORK: INSTALL NEW PLUMBING FOR WAREHOUSE OFFICE SPACE INCLUDING (2) MULTI- FIXTURE RESTROOMS .AND A BREAKROOM SINK AND DISHWASHER. Value of Plumbing /Gas Piping: Fees Collected: $14,500.00 $334.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 0 0 Industrial waste treatment interceptor, including 1 its trap and vent, except for kitchen type O grease interceptors 0 0 Repair or alteration of water piping and/or water 2 treatment equipment 0 O Repair or alteration of drainage or vent piping 0 4 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 O Medical gas piping (6 +) inlets /outlets 1 1 Gas Piping 1 Gas piping outlets (0 -5) 0 5 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -162 Printed: 06 -23 -2008 City o"Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PGO8 -162 Issue Date: 06/23/2008 Permit Expires On: 12/20/2008 Permit Center Authorized Signature: Date: W 23 -0 (c I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: Print Name: rec/ Cc 43 yr/ Date: 03/6 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -162 Printed: 06 -23 -2008 Parcel No.: 8836500100 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 350 MIDLAND DR TUKW CHASING FIREFLIES PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -162 ISSUED 05/27/2008 06/23/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed m compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work' is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -162 Printed: 06 -23 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: --- - da(-7--e_ Print Name: Date: 6,23 ,08 doc: Cond -10/06 PG08 -162 Printed: 06 -23 -2008 CITY OF TUKWIL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Plumbing/Gas Permit No. C t;' P`q Project No. 013-1t4 only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** .... ...... ..................... . SITE LOCATION Site Address: 357) /3g 6 /Y)/CJ/24x1' A Tenant Name: Chazing Fire F/+e� King Co Assessor's Tax No.: ?83 65-0 Of 00 Suite Number: New Tenant: Floor: .... Yes El ..No Property Owners Name: Aim/ l 9►r3perki Covp, Mailing Address: City State Zip CONTACT PERSON o we contact when your = permit i ready Name: j' —tred Lccig fates Mailing Address: a.IDON HC /15 E -Mail Address: -4 nb -hv.@. verizan. roo f Company Name: 1— e.un&torr1 Plum- Tare• Mailing Address: of !00 y A/L SA, Contact Person: i - d / Day Telephone: X06 q : - 6 2'/o /ZednO77d W( City State Fax Number: ' Z 5 ?el 833z 9905-3 Zip E -Mail Address: /4,•-rg./ov , Lam, h-/n ter) zon .hey Contractor Registration Number: L K►NG FP r oti,/ F 2 edniorwd City Day Telephone: 4//9- State a46 r 6 g.yo 48053 Zip Fax Number: Yg r rrs. f 8332 Expiration Date: /.Z /. p /Os, Company Name: /V , L Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: State Zip Q:\Applications\Forms- Applications On Line \3 -2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4.2006 bh City Day Telephone: Fax Number: State Zip Page 1 of 2 Valuation of Project (contractor's bid price): $ /L6 500 • od Scope of Work (please provide detailed information): r_es4jj n A -6,m b'na r (,) »r Monde p/ rce A. • Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty . Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain i_ Sinks / Dental unit, cuspidor Shower, single head trap Urinals / Dishwasher, domestic, with independent drain / Lavatory N Water Closet 5 Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment I ` Repair or alteration of drainage or vent piping I Medical gas piping system serving one to five inlets/outlets for specific gas ARPLICAJON =.NOTE Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: -7-e Print Name: l- -v--c/ Lcw,5 Mailing Address: g,/nay ,vt //5"-- Date: 51.1 Day Telephone: app 4/A f A yd 2edkria ci [of} QPOS3 City State Zip Date Application Accepted: jn l Date Application Expires: 1 1 ( „ rq=. Staff Initials:/ Q:\Applications\Forms- Applications On Line13 -2006 - Plumbing -Gas Piping Penni Application.doc Revised. 4 -2006 bh Page 2 of 2 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 8836500100 350 MIDLAND DR TUICW CHASING FIREFLIES RECEIPT Permit Number: Status: Applied Date: Issue Date: PG08 -162 ISSUED 05/27/2008 06/23/2008 Receipt No.: R08 -02460 Initials: JEM User ID: 1165 Payment Amount: Payment Date: Balance: $60.00 07/08/2008 02:42 PM $0.00 Payee: LANGFORD PLUMBING, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8025 ACCOUNT ITEM LIST: Descript ion 60.00 Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.0 60.00 Total: $60.00 4557 07/08 9711 TOTAL 60.00 don: RPCPint -OR PrintM 07- (1R -200R City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http. / /www.ci.tukwila.wa.us Parcel No.: 8836500100 Address: 350 MIDLAND DR TUKW Suite No: Applicant: CHASING FIREFLIES RECEIPT Permit Number: PG08 -162 Status: APPROVED Applied Date: 05/27/2008 Issue Date: Receipt No.: R08 -02232 Initials: WER User ID: 1655 Payment Amount: $272.00 Payment Date: 06/23/2008 02:34 PM Balance: $0.00 Payee: LANGFORD PLUMBING TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8019 272.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.0 272.00 Total: $272.00 3972 06/23 9710 TOTAL 272.00 doc: Receiot -06 Printed: 06-23 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 8836500100 Address: 350 MIDLAND DR TURN/ Suite No: Applicant: CHASING FIREFLIES RECEIPT Permit Number: PG08 -162 Status: PENDING Applied Date: 05/27/2008 Issue Date: Receipt No.: R08 -01821 Payment Amount: $62.00 Initials: JEM Payment Date: 05/27/2008 04:28 PM User ID: 1165 Balance: $272.00 Payee: LANGFORD PLUMBING, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8011 62.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 62.00 Total: $62.00 2914 05/28 9711 TOTAL 62.00 rinrr Rarpint -OR PrintAd n5- 27 -20(lR INSPECTION NO. INSPECTION RECORD Retain a copy with permit -/6Z PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Ire. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6'0 Pro' �tj^` ---; ■'7/7/ A/6" hte ;2/cc Type of n ection r n,` ( Address- 3 i 0 h'1 /:ate alf) Date Called: Special Instructions: Date Wanted: Requester: Phon N 92- %cf5?/2 _ Approved per applicable codes. QCorrections required prior to approval. G. COMMENTS: Inspector :,' Date: F j _ ,� �1 j1 uU $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit IN PECTION NO. PERMIT NO. R,68142 CITY OF TUKWILA BUILDING DIVISION 4- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 Pr a t: y Type of Inspection: Date: Addr 510, 0 1 b ^ �� Date Called: Special Instructions: Date Wanted: 9 - 1 l -t - Oa m.. • p.m. Requester: Phone No' ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: a `14,0 } \IN Mel d eS vai , /`.s 1(4 �v 7 ijL1skQr \, Inspec or: y 010,\_,A, l WI 1.\ Date: S-- ( k , ()t ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to scheduleireinspection. Receipt No.: ,Date: , INSPECTION NO. INSPECTION RECORD Retain a copy with permit 0 —/ �- PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188' (206)431 -3670 Projec - r 1.d r ''c S Type of Inspection: fit. ", ,,i f _.,.,,, Address: Date Called: Special Instructions: Date Wanted: ^# / ° rU a.m^ p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspecto Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: 6.6.6666,6•5666/06626.6.6.6-6.1.66.666666:6166.66 -226.661•66.6661mItn66 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188- INSPECTION RECORD Retain a copy with permit PGae- 1(O L PERMIT NO. (206)431 -3670 Project: Type of Inspection: Address: 1 35th iAlk , itA ek. OlAi.e Date Called: n Special Instructions: Date Wanted: a.m. 1- % uk p.m. Requester: Phone f r `3 4515 0 Approved per applicable codes. orrections required prior to approval. COMMENTS: n ` f t `- A Inspe tor: 41„),A Date:.. -7 _ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit Proe8 1(2 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION CL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Proj ,/�i (/ q • ' / i fi 1J t it Type of 1 ectio{�n �: 9{ jy/ 1'i- -_ Ad ress �/y'� _ ,f4 Date Called: Specia Instructions: Date Wanted: {', Req er: Phone No: Lesr'11X62c/L. 121 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: - ,..i ....4) 1 ; q 1 , f Y Inspecto jk■ 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Z S�" Date: CHASING. FIREFLIES -f-enan+- ivnprrvevhen+ -- _WASTE +- VENT ISO NIt_"T"2IC /as II..t / t1. N Ti P %;N k„ A 1 r— 'N011`331:1E103 — -J r IN 411-1 0 x T tv eTi r) io „,...,.. to ec?.* ,,,,,,„.: l'i ra/ 'A V-1-11\ ca 0 00 ro 50 -360 inclIc.vld Drive_ LANGFORD PLUMBING, INC. 21004 NE 115th ST. Redmond, Washington 98053 (425) 882 -0361 Fax (425) 881 -8332 LIC #LANGFPI044R8 czei —7 June 5, 2008 • . City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Fred Langford 21004 NE 115th Street Redmond, WA 98053 RE: CORRECTION LETTER #1 Plumbing /Gas Piping Application Number PG08 -162 Chasing Fireflies — 350 -360 Midland Drive Dear Mr. Langford, This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Public Works Department has no comment. Building Department: Allen Johannessen at 206 - 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Brenda Holt Permit Coordinator encl xc: File No. PG08 -162 Center \Correction Letters\2008\PG08 -162 Correction Ltr # 1.DOC wer A2/)11 en.rfhnonflaw Rnrllaw•s.rl Cr.ita #11)/) a T..G•■;l.. TAL, 1. ;...F.... 0121 DD - D3. ., .. 1 /16 491 9A '7I1 - C..... •116 Alf 966c • • Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: June 2, 2008 Project Name: Chasing Fireflies Permit #: PG08 -162 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide isometric drawings for the new plumbing system. Show pipe vents for the fixtures and identify where all plumbing vents shall connect to a vertical stack extending through the roof. One 3 inch vent is shown; however it is not clear where the new fixtures shall be vented. (2006 UPC 901.0 & 904.0) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. HERMIT COORD C0Pr � PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -162 DATE: 06 -12 -08 PROJECT NAME: CHASING FIREFLIES SITE ADDRESS: 350 MIDLAND DR Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Buy • g i isio Public Works Fire Prevention Structural n Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 06-17-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTI G: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 07-15-08 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 •PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -162 DATE: 05 -27 -08 PROJECT NAME: CHASING FIREFLIES SITE ADDRESS: 350 MIDLAND DR X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: ng i ivision Fire Prevention ri Planning Division Publs orks 4(;_v Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ri Permit Coordinator n DUE DATE: 05-29-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 06 -26-08 Approved Approved with Conditions n Not Approved (attach comments) J/ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: (0--14'68 Departments issued corrections: Bldg Er Fire ❑ Ping ❑ PW ❑ Staff Initials Documents/routing slip.doc 2 -28 -02 • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 6//' /07 Plan Check/Permit Number: P& OS' -- /62. Er- -R___esponse o._Incomplete Letter #. / Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner r EC TENE®It.,9 JUN 12 2008 NERMIT CENTER Project Name: 0,00 f h5, Fare -t i e)a Project Address: 35D — 3 6 11 c.1 Iaa idd IA r,' ate Contact Person: Fred LCutjfavcl Phone Number: a z/65" 62.40 Summary of Revision: .1'-se-r4eArk_ dw V1-t5 aA fr& i(9114c, koz.�ivlc Valli- He -r''n. .'- ue F s-cisfe pr Sheet Number(s): / "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by:, Entered in Permits Plus on (Pt 2W \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License LANGFPI044R8 Licensee Name LANGFORD PLUMBING INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601707476 Ind. Ins. Account Id 59383401 Business Type CORPORATION Address 1 21004 NE 115TH ST Address 2 City REDMOND County KING State WA Zip 98053 Phone 4258820361 Status ACTIVE Specialty 1 PLUMBING Specialty 2 UNUSED Effective Date 12/28/1996 Expiration Date 12/28/2008 Suspend Date Separation Date Parent Company Previous License LANGFP* 118R8 Next License LANGCI *927LR Associated License Business Owner Information Name Role Effective Date Expiration Date LANGFORD, FRED F 01/01/1980 LANGFORD, ROSEMARY H 01/01/1980 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #4 FEDERATED MUTUAL INS 9127483 12/01/2004 Until Cancelled $6,000.00 12/01/2004 DEVELOPERS https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= LANGFPI044R8 06/23/2008 GENERAL NOTES 1. THE APPROVED PLANS SHALL NOT BE CHANGED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING OFFICIAL_ THE APPROVED PLANS ARE REQUIRED TO BE ON THE JOB SITE. 2. CONTRACTOR SHALL VERIFY AND CHECK ALL CONDITIONS AND DIMENSIONS AT THE BUILDING. REPORT ANY INCONSISTENCIES TO THE ARCHITECT. 3. ALL WORK SHALL MEET LOCAL CODES AND ORDINANCES. 4. ALL NAILING SHALL COMPLY WITH NAILING SCHEDULE OF THE 2006 IBC. 5. COMPLIANCE CARD TO BE POSTED VERIFYING INSULATION INSTALLE=D IN WALL, CEILINGS ANDS FLOORS (IF REQUIRED). 6. PROVIDE METAL NAIL STOPPERS TO COYER HOLES IN STUDS WHI=R!" NAILS COULD PUNCTURE PLUMBING AND WIRING. 1. MAINTAIN 3' MIN. CLEARANCE BETWEEN CEILING FIXTURES AND INSULATION. 8. ALL WOOD COMING IN CONTACT W/ CONCRETE. SHALL BE PRESSURE TREATED (DECAY RESISTANT). 9. CONTRACTOR DESIGNED ELECTRICAL. SUBMIT TO BUILDING DEPARTMENT FOR PERMIT. PROFESSIONAL STAMP REQUIRED. 10. CONTRACTOR DESIGNED MECHANICAL. SUBMIT TO BLDG. DEPARTMENT FOR PERMIT. PROFESSIONAL STAMP REQUIRED. 11 SERVICE WATER PIPES TO BE INSULATED TO MINIMUM R:8 IN UNHEATED SPACES. 12. METAL DUCTS TO BE INSULATED AND JOINTS TO BE TAPED. 13. BATT INSULATION SHALL HAVE ALL TEARS AND JOINTS SEALED WITH TAPE. 14. WALLS TO BE FIRE STOPPED. I. IF ANY ERRORS, OMISSIONS OR INCONSISTENCIES APPEAR IN THE DRAWINGS, SPECIFICATIONS OR OTHER DOCUMENTS, NE CONTRACTOR SHALL NOTIFY THE OWNER OR ARCHITECT IN WRITING OF SUCH OMISSIONS, ERRORS, OR INCONSISTENCIES BEFORE PROCEEDING WITH THE WORK, OR ACCEPT FULL RESPONSIBILITY FOR COSTS TO RECTIFY SAME. 16. TYPICAL DETAILS OR BUILDING STANDARDS SHALL APPLY WHERE NO SPECIFIC DETAILS ARE GIVEN. 11. ALL DIMEN5ION5 SHALL TAKE PRECEDENCE OVER SCALE SHOW ON PLANS, ELEVATIONS, SECTIONS AND DETAILS. 18. ALL EXIT DOORS TO BE OPERABLE FROM INSIDE THE BUILDING WITHOUT KEYS OR SPECIAL KNOWLEDGE. I. FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA *10, OR REQUIREMENTS OF LOCAL FIRE OFFICIALS. 20. ALL INTERIOR WALL COVERING MATERIALS SHALL BE FIRE RESISTIVE OR SHALL BE TREATED TO BE FIRE RESISTIVE, SO AS TO RESULT IN A FLAME SPREAD RATING OF AT LEAST CLASS III FOR GENERAL AREAS AND CLASS II FOR EXIT WAYS, DELIVER CERTIFICATE TO LOCAL FIRE DEPARTMENT AS REQUIRED_ 21. ALL EQUALS TO BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO CONSTRUCTION. 22. BIDDER DESIGN WORK TO BE APPROVED BY ARCHITECT PRIOR TO CONSTRUCTION. 23. PENETRATIONS, IN WALL REQUIRING PROTECTED OPENINGS ARE TO BE FIRE STOPPED 24. COORDINATE WIN OWNER AND DESIGN TEAM FOR LOCATION OF ELECTRICAL, MECHANICAL AND PLUMBING. 25. TACTILE SIGNS STATING 'EXIT' AND COMPLYING WITH ALL ICC /ANSI A111.1 REQ. SHALL BE PROVIDED AT EACH EXIT DOOR PER 103.3.11 AND CHAPTER 1 IN GENERAL 26. THE MEANS OF EGRESS INCLUDING THE EXIST DISCHARGE SHALL BE ILLUMINATED AT ALL TIME5 THE BUILDING 15 OCCUPIED PER IBC 1006.1 ELECTRICAL DESIGN BUILD CONTRACTOR SHALL COMPLY AND SHALL SUBMIT A DEFERRED SUBMITTAL MEETING ALL REQUIREMENTS. 21. THE BUILDING SHALL BE EQUIPPED WITH EMERGENCY LIGHTING AND IN THE EVENT OF A POWER FAILURE SHALL AUTOMATICALLY ILLUMINATE THE AREA OF THE EXIT DISCHARGE IMMEDIATELY ADJACENT TO THE DISCHARGE DOORS PER IBC 10063 ELECTRICAL DESIGN BUILD CONTRACTOR SHALL COMPLY AND SHALL SUBMIT A DEFERRED SUBMITTAL MEETING ALL REQUIREMENTS. 28. PROVIDE A TACTILE EXIT SIGN TO COMPLY WIN ICC A111.I. 29. PROVIDE 90 MINUTE OF EMERGENCY LIGHTING AT ALL EXTERIOR DOORS VIA SEPARATE BATTERY OR UNIT EQUIPMENT. 30. PROVIDE LOCKING DEVICE READILY DISTINGUISHED AS LOCKED WITH SIGN ON POOR STATING 'THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED IN I' HIGH LETTERS. 31. THE MEANS OF EGRESS INCLUDING THE EXIT DISCHARGE SHALL BE ILLUMINATED TO MINIMUM I FOOT- CANDLE AT ALL TIMES THE SPACE 15 OCCUPIED BY PREMISES ELECTRICAL SUPPLY. IN EVENT OF A POWER FAILURE THE LIGHTS SHALL OPERATE FOR A MINIMUM OF 90 MINUTES. 32. ALL TACTILE CHARACTER SIGNS SHALL BE MOUNTED AT 48' AFF. WITH A MAX. HEIGHT OF 60' AFF. ADJACENT TO THE LATCH SIDE FOOT OF THE DOOR PER ANSI AII1.1 -2003 4 1033.10 AND Il. 33. PROVIDE VENTILATION AS REQUIRED BY WVIAC AND SUBMIT DESIGN TO CITY FOR REVIEW. 34. MANUALLY OPERATED FLUSH BOLTS ARE NOT PERMITTED AND NO MORE THAN ONE OPERATION FOR THE UNLATCHING 15 ALLOWED. SYMBOLS X X. ROC A Q BUILDING SECTION WALL SECTION DETAIL INTERIOR FINISH WALL ELEVATIONS GRID LINES - COLUMN ROOM NAME AND NUMBER REVISION TAG DOOR TAG ILLUMINATED EXIT SIGN WITH EGRESS PATH LIGHTING WITH BATTERY BACKUP SYSTEM LEGAL DESCRIPTION UPLANDS TUKWILA INDUSTRIAL PARK BEG NW COR LOT 10 TH S 0I -49 -28 W 31638 FT TO S LN LOT 9 TH 5 S1 -55 -02 E 44020 FT TO 5E COR LOT 10 TH ALG CURVE TO LFT RAD 40834 FT RAD !SEARING N 89 -23 -56 W ARC DIST 95.18 FT 4 C/A 13 -21 -11 TH ALG CURVE TO LFT RAD 35926 FT ARC LENGTH 11130 FT 4 C/A I1 -45 -02 TAP OF REV CURVE TH ALG CURVE TO RGT RAD 35926 FT ARC LENGTH 191.12 FT 4 CIA OF 30 -34 -32 TO NE COR LOT 10 TH N 81 -55 -04 W 32150 FT TO TPOB ABBREVIATIONS A.C.T. AFF. ALUM. A5PH. ANOD. BM. D. BLDG. BLK'G. CLG. COL. CONC. CONST. CONT. D/F. DTL. DIA.(4) DIM. D.S. DR DWG. E.F. EJF.S. ELEC. ELEV. ENG. EQ. EQUIP. EXIST. EXP. EXT. E.W.G. GA, GALV. GL GLB. 6YP. G.IUB. RP. c HGT. ,1CP. HR HORIZ. H.B. ACOUSTICAL CEILING TILE ABOVE FINISHED FLOOR ALUMINUM ASPHALT ANODIZED BEAM BOARD BUILDING BLOCKING CEILING CENTER LINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS DRINKING FOUNTAIN DETAIL DIAMETER DIMENSION DOWNSPOUT DOOR DRAWING EXHAUST FAN EXT. INSUL. FINISH SYSTEM ELECTRICAL ELEVATION ENGINEER EQUAL EQUIPMENT EXISTING EXPANSION EXTERIOR ELECTRIC WATER COOLER FE. FIRE EXTINGUISHER FE.C. FIRE EXTINGUISHER CABINET FACFIN. FACTORY FINISH FD. FLOOR DRAIN F.D.C. FIRE DEPT. CONNECTION FT. FEET F.F. FINISHED FLOOR F.H. FIRE HYDRANT FIN. FINISH FL. FLASHING FLR FLOOR FTG. FOOTING FDN. FOUNDATION P.O.G. FACE OF CONCRETE P.O.F. FACE OF FRAMING GAUGE GALVANIZED GLASS GLU- LAMINATED BEAM GYPSUM GYPSUM WALL BOARD HIGH POINT HIGH PRESSURE SODIUM HARDWARE HEIGHT HANDICAP HOUR HORIZONTAL HOSE BIBB WALL LEGEND CONTACT AfMHITECT PICAS ARCHITECTURAL GROUP 603 STEWART ST. SUITE 101 SEATTLE, WASHINGTON 98101 (206) 624 -3210 ph (206) 624 -3243 fax DRAWING LIST 5D -1 COVER/DATA SHEET 4 SITE PLAN A -I 15T FLOOR PLAN A -2 DETAILS 4 ELEVATIONS INSUL. INSULATE (INSULATION) NT. INTERIOR JT. JOINT JST. JOIST LAY. LAVATORY MFR NATL. MAX. MECH. MTL. MIN. MIx N.T.S. NO.( *) N.I.G. OFF. O.C. O.F.L. O.P. OPNG. PNL. PTN. PLLAM. PLYWD. PL. P4P RL. REC. RECP. REINF. RD. R1. REFL. SHT. SPG. SPEC. STD. STL. STRUCT. 54V. TELE. TEMP. T. T.O.P. TYP. T.I. T.W.C. Y.C.T. Y.W.C. VENT. YERT. W.C. W.COV. W.H. W.R WD. MANUFACTURER MATERIAL MAXIMUM MECHANICAL METAL MINIMUM MIXTURE NOT TO SCALE NUMBER NOT IN CONTRACT OFFICE ON CENTER OVERFLOW LEADER OPERABLE OPENING PANEL PARTITION PLATE PLASTIC LAMINATE PLYWOOD PROPERTY LINE PATCH AND PAINT RAIN LEADER RUBBER BASE RECEPTION RECEPTACLE REINFORCING ROOF DRAIN ROOM REFLECTED SHEET SIDING SPECIFICATION STANDARD STEEL STRUCTURAL STAIN AND VARNISH TELEPHONE TEMPERED TOILET TOP OF PARAPET TYPICAL TENANT IMPROVEMENT TACKABLE WALL COVERING U.ON. UNLESS OTHERWISE NOTED IE AMB PROPERTY CORPORATION 12120 GATEWAY DRIVE, SUITE 110 TUKWILA, WA 98168 (206) 241 -1103 ph (206) 24I -2191 fax VINYL COMPOSITION TILE VINYL WALL COVERING VENTILATE VERTICAL WATER CLOSET WALL COVERING WATER HEATER WATER RESISTANT WOOD EXISTING WALLS TO REMAIN 6' METAL STUD WALL 6 I6' 00 WI GWB ,AT INTERIOR. PROVIDE R -I9 BATT INSULATION W/ Y. . WARM SIDE AND EXT. SHEATHING PER STRUCTURAL. EXT FINISH PER ELEVATIONS 3 1/2' METAL STUD WALL 6 24' OC W/ GM EACH SIDE. PROVIDE SOUND BATT INSULATION AT TOILET ROOMS EXISTING WALL TO BE DEMOLISHED ENERGY INFORMATION I. ELECTRIC RESISTANCE HEATING IS THE EXISTING HEATING SOURCE. 2. R -VALUE OF ALL NEW INSULATION SHALL BE AS FOLLOWS: EXISTING EXTERIOR WALLS R -19 EXISTING EXISTING VERTICAL GLAZING U =0.40 (MAX) SHGC to (MAX) 3 • ALL FACED BATTS TO BE FACE STAPLED. 4 . PROVIDE I' MIN. AIRSPACE ABOVE ALL ROOF INSULATION AND PROVIDE VENTING AT A MIN. RATE OP 1/300 OF AREA VENTILATED. S. GLAZING AREA CALCULATION: 6. 1. S. 10. 11. T U VALUES FOR EXTERIOR DOORS EXISTING DOOR U :0.60 MAX SHADING COEFFICIENT FOR GLAZING = 100 MAX ALL VAPOR RETARDERS TO BE INSTALLED ON WARM SIDE OF INSUL. REPAIR OR PROVIDE NEW SEALING, CAULKING AND GASKET AS REQ. BY NREC 5EE GENERAL NOTES FOR ADDITIONAL INFO. REPLACE ALL DAMAGED WEATHER- STRIPPING MECH. CONTRACTOR TO INSPECT ALL EXISTING DUCTWORK AND REPLACE DAMAGED OR MISSING SEALS, CAULKING 4 GASKETS. (AS APPLICABLE) NO NEW EXTERIOR WALLS, DOORS OR WINDOWS FOR THIS PERMIT. SITE & BLDG. STATS BUILDING BUILDING OWNER GOVERNING CODE ZONE TAX PARCEL NUMBER BUILDING TYPE OCCUPANCY TYPE SITE AREA PARKING PROJECT DESCRIPTION 3'1' PAIR WOOD DOOR PER BUILDING STANDARDS HMTL FRAME, PER BUILDING STANDARDS KEYING MECHANISM - SUBMIT KEYING SCHEDULE TO OUNER ✓ HARDWARE PER BUILDING STANDARDS ✓ 3 HINGES PER DOOR ✓ CLOSER ✓ CLASSROOM LOCKSET TO BE LEVER HARDWARE ✓ 3 SILENCERS Q EXISTING DOOR TO REMAIN SEE NOTE 18 IN THE GENERAL NOTES r HJM. DOOR 4 FRAME r MIDLAND DISTRIBUTION CENTER 350 -360 MIDLAND DRIVE TUKWILA, WASHINGTON AMB PROPERTY CORPORATION HA 2006 IBC W/ WASHINGTON STATE AMENDMENTS C- COMMERCIAL 8836500100 V - SPRINKLED 5 -! (WAREHOUSE) B (OFFICE) 144A13 SF (3.32 ACRES) - UNCHANGED EXISTING - UNCHANGED EXISTING AREA FOR ENTIRE BUILDING: 14,951 SF - UNCHANGED AREA OF NEW WORK: 320 SF COMMERCIAL TENANT IMPROVEMENT. NEW MEN'S 4 WOMEN'S ROOMS. OPTIONAL BREAK AREA SHOW. HARDWARE CHEDULE KWILA, WASHINGTON 30' -0' RAILROADI RO.W. EAS MENT ING FIREFLIES SITE CHRYSTAL SPRINGS PARK BOW LAKE 116TH ST PARK WESTFIELD - SOUTHCENTER TUKWILA POND NKLER BLYD~ I80TH ST VICINITY MAP AS SHOWN N 81'56'04' W 32150' 1(o7 NOTE:_ EXISTING BUILDING ENVELOPE TO REMAIN UNCHANGED EXISTING PARKING TO REMAIN 1 5 81'55'02' E 44020' MIDLAND DRIVE SITE PLAN REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 0 2088 I 1 E ..... � MAY 2 7008 TUKVVILA PUBLIC WORKS 30' -0' RAILROAD I RO.W. EAS MENT \ ■ Ci Of Tukwila BUILD ".NG DIVISIC Plar revlevt Approval G the violatio of approve( By ORILLIA I BOEING LONGACRES INDUSTRIAL PARK Per ■ Date EXISTING PARKING TO REMAIN it No. approval Is sub ect to errors and omissions. construction documents does not author 1 of any adopted code oras ordinance. s ��� � d' Fiat Copy and con R - 35926' A = 30'34'32' T = 98.02' L = 191.11' Fl HY City of Tukwila BUILDING DIVISO SEPARATE PERMIT REQUIRED FOR: e Mechanical jg Electrical ❑ Plumbing g9Gas Piping City of Tukwila BUILDING DIVISION R - 35926' A = 11'45'02' L = 40.53' ai• s :s R - 35926' A - 11'11'14' T = 3550' L = 10.11' I R 8' I t A 1340'21'11' I T 41ST34' I L= 95.18' I I J r thEIV�D CITTOF TUKVIfiLA MAY 2 7 2008 PERMIT CENTER ARCHITECTURAL GROUP PS. SEATTLE OFFICE 603 STEWART STREET SUITE 707 SEATTLE, WASHINGTON 98101 (206) 624 - 3210 FAX 624 - 3243 WENATCHEE OFFICE 112 OLDS STATION RD. SUITE B WENATCHEE, WASHINGTON 98801 (509) 664 - 5181 FAX 665 -8750 VJ W J cc � W z W Er Z >o 0 cc 1- o � LL ? °z mQ� J Q Eu) � Q O J - 6f5 o Y Q m Z a U 4879 REGISTERED AR ECT DRAWN CMW CHECKED GAP DATE 5/23/2008 SCALE AS NOTED JOB NO. 08024 . PRRCICH WASHINGTON Ckwsi Rre4W S'p'y P(umi In g ff01-1(f FILE: RPPA LOCATION PLAN SCALE: I' =10' -0' EXISTING 2° WATER METER 34016292 I I I I I \ \ \ NEUJ FE CO SERIES 060 RFF4 UJITN 1452 RIOT Sax ON A 50" x 24° X4" CONCRETE PAD -- v $E /I T-14116613 1.6 .t. d S24B r • 4-- 1 u REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 0 2008 City Of Tukwila BUILDIBUMSIQL CITY OF RECEIVED MAY 2 7 2008 PERMIT CENTER SEATTLE OFFICE ARCHITECTURAL GROUP PS. 603 STEWART STREET SUITE 707 SEATTLE, WASHINGTON 98101 (206) 624 - 3210 FAX 624 - 3243 WENATCHEE OFFICE 112 OLDS STATION RD. SUITE B WENATCHEE, WASHINGTON 98801 (509) 664 - 5181 FAX 665 -8750 4879 REGISTERED AR ECT DRAWN CMW CHECKED GAP DATE 5/23/2008 SCALE AS NOTED JOB NO. 08024 FILE: . P RCICH WASHINGTON SD -2 EXISTING TO REMAIN, TYP. 50' EXISTING TO REMAIN, TYP. i 50' -0" i ■-- r U- F 310' -0" SCALE: 1/16" =1' -0" 50' - 0" r FIRST FLOOR PLAN 50' -OI AREA OF WORK, SEE SHEET A -2 FOR ENLARGED PLAN f 60' -0" A%i5. 1`li i rce EXISTING TO ;g. ' ■ REMAIN, P. te,. dot . b 540.11e4 r r N 5. v in 10 0 REVIEWED FOR — CODE COMPLIANCE i APPROVED JUN 2 0 2008 City Of Tukwila BUILDING DLTML RECEIVE CITY OF TU LA MAY 2 7 2008 PERMIT CENTER Q Lip 0 5 I- W d C.) z a 5 ce 0 U- 0 w I- H- CO D ARCHITECTURAL GROUP PS, SEATTLE OFFICE 603 STEWART STREET SUITE 707 SEATTLE, WASHINGTON 98101 (206) 624 - 3210 FAX 624 - 3243 WENATCHEE OFFICE 112 OLDS STATION RD. SUITE 0 WENATCHEE, WASHINGTON 98801 (509) 664 - 5181 FAX 665 -8750 VJ W cc �W w fro z >o 0 CC I— ° j o z mz= ♦R �o Z pJ QoY 0 � � am U 4-879 REGISTERED AR ECT DRAWN CMW CHECKED GAP DATE 5/23/2008 SCALE AS NOTED JOB NO. 08024 . P RCICH WASHINGTON A -1 FILE: • 3'=1'-0 3" =1'-0' WC /ADA GENERAL NOTE: CEILING JOISTS: 6005162 -043 6 12'0.C. WALL STUDS: 350 5!62 -033 6 24'0.C. WALL DETAIL SCD /ADA WC WR/PTD 1/2' :1' -0' BLOCKING AS NEEDED J CEILING 5' -6' A.F.F. %8' TYPE 'X' GWB, EACH SIDE OVER METAL STUDS • DOOR JAMB SIMILAR G.W.B. BOTH SIDES OVER '�Z' MIL STUDS to 2' -0' O.C. WITH BATT INSULATION WHERE INDICATED ON PLAN METAL FRAME, PAINTED, SEE SPEC. DOOR SILENCERS, SEE DOOR SCHEDULE DOOR PER DOOR SCHEDULE, SD -1 DOOR HEAD DETAIL RESTROOM NOTES: I. FOR PLUMBING FIXTURE LOCATIONS, REFER TO ENLARGED PLANS 2. INSTALL 13I-KG. IN WALL AT ALL RECESSED AND SURFACE MOUNTED TOILET ACCESSORIES. 3. FULL HEIGHT CERAMIC TILE WAINSCOT PER SPEC 4. FLOOR FINISH TO BE PER SCHEDULE AND SPECIFICATIONS 5. INSULATE HOT WATER AND DRAIN LINES OF WHEELCHAIR ACCESSIBLE LAVATORIES. 6. REFER TO DETAIL THIS SHEET FOR STANDARD MOUNTING HEIGHTS OF FIXTURES 1. URINAL SCREEN NOT TO EXTEND BEYOND FRONT EDGE OF URINAL RIM. a TOILET STALL PLAN MAY BE OPPOSITE HAND. REFER TO ENLARGED PLANS FOR CONFIG. S. MOUNT ADA DRINKING FOUNTAIN WITH SPOUT NO MORE THAN 36' AFF UR/ADA GRAB BAR X ao 3 c• UR WALL DETAIL 3'.1'-0' EXISTING LINE OF WALL STD. MOUNTING HGTS. l'-10' l'-10' 2' -0' J , +/— 4' -0' J , EQ. J , Q . MICROWAVE SPACE (2) ADJUSTABLE SHELVES 1/4' :1' -0' N OPTIONAL BREAK AREA TOILET ACCESSORY ABBREVIATIONS NOTE:, KNEE SPACE UNDER SINK, NO BASE CABINET ADA AMERICANS WITH DISABILITIES ACT AP ACCESS PANEL CH COAT HOOK OF DRINKING FOUNTAIN GB GRAB BAR (G131 =%' LONG, G152 :42' LONG) MIR MIRROR MRGWB MOISTURE RESISTANT GWB - 5 /S' THICK PTD PAPER TOWEL DISPENSER SCD TOILET SEAT COYER DISPENSER 5ND SNDL r PARTITION MIRROR IS TT (1' MIN) GAUGE DEEP TRACK TO 12' AFF. PROVIDE BRACING AT TOP OF WALL AS REQUIRED OR SECURE WALL TO STRUCTURE ABOVE 1 350T150 -0431 349 METAL STUD WALL W. GUS PTD SMOOTH FIN. W/ SOUND BATTS AS REQ. GLOB CLG TAPED 4 SANDED W/ PTD FIN. TO MATCH WALLS ON 6' CEILING JOISTS to 12' OC SD SND SNDL STS TPD TPTN URSCR WC WR TPD — REFRIGERATOR 4 COOLER 9 N PLASTIC LAMINATE ALL SUWACE5 SOAP DISPENSER SANITARY NAPKIN DISPENSER SANITARY NAPKIN DISPOSAL STANDARD TOILET STALL TOILET PAPER DISPENSER TOILET PARTITION URINAL SCREEN WATER CLOSET WASTE RECEPTACLE. r C ROLL LAY v 3 i o WALL HEIGHT I2' -0' ',1' -0' A 2' -0' CLEAR WALL BASE DETAIL RESTROOM DETAIL 5/5' GWB OVER 3 1/2' METAL STUDS, PAINT PER BLDG STANDARD XDNI POWER DRIVEN HILTI FASTENER 24' OC EMBED 1 -1/2' CARPET 4 RUBBER BASE PER BLDG. STD COLOR AS SELECTED BY OWNER PATCH 4 REPAIR EXISTING CONCRETE AS REQ'D. TO RECEIVE CARPET FLUORESCENT LIGHT FIXTURE PER ELECTRICAL 5/S' WATER RESISTANT GWB (TYP.) PAINTED GWB BEYOND 5/5' GM TYPE 'X' MOISTURE RESISTANT SOUND ATTENUATION INSULATION IN EACH WALL (TYP.) PLATE GLASS MIRROR FROM BACKSPLASH TO LOUVER PROVIDE SINKS 4 FAUCETS TO MEET STATE 4 LOCAL HC CODE PLASTIC LAMINATE COUNTERTOP 4 4' BACKSPLASH PROVIDE BRACE AT EACH END OF COUNTERTOP, INTEWEDIATE BRACE AT CENTER, BUT NOT TO EXCEED 3' -6' O.C., BRACES TO BE 3/4' PLYWOOD WITH PLASTIC LAMINATE AROUND TO MATCH COUNTERTOP PROVIDE BLOCKING AS REQUIRED SCALD RESISTANT WRAP P -LAM WALL FINISH SEE ELEVATION 51-IEET VINYL FLOORING INTEGRAL WITH BASE EXISTING CONCRETE FLOOR SLAB TOILET PARTITION VINYL FLOORING 111/ 6' INTEGRAL COVED BASE — TOILET PAPER DISPENSER RESTROOM DETAIL, TYP. 1/4'.1'-0' (Leg-- 4' -6" . 1" —9 5' -0' MOISTURE RESISTANT GYP BOARD CEILING 4 WALLS, PAINTED 1-V DIA. GRAB BARS, PROVIDE BLOCKING IN WALL, TYP PLASTIC LAMINATE ON WET WALLS UP MOISTURE RESISTANT GYP BOARD CEILING 4 WALLS, PAINTED — V$' DIA. BRUSHED S.SGRAB BAR TYP. PLASTIC LAMINATE TOILET 9 PARTITION 4 SCREEN 1/4' =1' -0' f =l ll 5' - 2' —I0' 2' -10' 6' COVED BASE INTEGRAL WITH FLOORING PLASTIC LAMINATE WAINSCOT TO 4' -0' AFF. IN RESTROOM AT WET WALLS • // ENLARGED FLOOR PLAN RLVIEWED EOR� CODE COMPLIANCE APPROVED JUN 2 0 2008 Cllr Qf Tukwila BUILDING DIVISION PROVIDE PAPER TOWEL DISPENSER ON WALL ADJACENT TO SINK MOUNT AT 40' AFF TO OPERATING CONTROL, WITH MAX. REACH DEPTH NOT TO EXCEED 5', PER ANSI 606.E PLATE GLASS MIRROR TO 7' -0' APP. W/ BOTTOM EDGE AT 40' AFP. MAX, FULL WIDTH OF COUNTERTOP LEPER TYPE FAUCET, TYP. INSULATE ALL EXPOSED PIPES. NO ROUGH EDGES ALLOWED NOTES: 1. INSTALL BLOCKING IN WALL AT ALL RECESSED AND SURFACE MOUNTED TOILET ACCESSORIES, TYP. 2. TOILET FLUSH CONTROL HANDLES SHALL BE MOUNTED FOR USE FROM THE WIDE SIDE OF THE STALL AND NOT MORE THAN 44' AFP. PER ICC A117.1, SECTION 604.6, TYP. RESTROOM DETAIL, TYP. ALIGN WALL ON EXISTING COLUMN EXISTING TO REMAIN, NO WORK, TYP. --- RECEIVED CITY OF TUKIMLA MAY 2 7 2008 PERMIT CENTER 0 m O z 1— o w CL ca z 0 J 5 m 0 LL w m ARCHITECTURAL GROUP PS. SEATTLE OFFICE 603 STEWART STREET SUITE 707 SEATTLE, WASHINGTON 98101 (206) 624 — 3210 FAX 624 — 3243 WENATCHEE OFFICE 112 OLDS STATION RD. SUITE B WENATCHEE, WASHINGTON 98801 (509) 664 — 5181 FAX 665 -8750 4879 REGISTERED AR ECT . P DRAWN CMW CHECKED GAP DATE 5/23/2008 SCALE AS NOTED JOB NO. 08024 A -2 FILE: RC ICH WASHINGTON I