Loading...
HomeMy WebLinkAboutPermit PG08-163 - WESTFIELD SOUTHCENTER MALL - TUTTI FRUTTI FROZEN YOGURTTUTTI FRUTTI FROZEN YOGURT 2800 SOUTHCENTE PGO8-163 MALL Parcel No.: 6364200010 Address: Suite No: Cit3411bf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 2800 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -163 07/21/2008 01/17/2009 Tenant: Name: Address: Owner: Name: Address: TUTTI FRUTTI FROZEN YOGURT 2800 SOUTHCENTER MALL, K0305 , TUKW LA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA Contact Person: Name: MARCIA PEDDICORD Address: 633 SOUTHCENTER MALL, TRAILER 3 , TUKWILA WA Contractor: Name: DENNIS THE PLUMBER Address: 107 EAST 3RD , CLE ELUM WA Contractor License No: DENNIP*965DJ Phone: Phone: 818 402 -8923 Phone: 253 862 -1241 Expiration Date: 03/14/2010 DESCRIPTION OF WORK: TENANT IMPROVEMENT FOR NEW KIOSK INCLUDING INSTALLATION OF AN INSIDE GREASE TRAP /INTERCEPTOR. Value of Plumbing /Gas Piping: Fees Collected: $3,000.00 $211.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per dram (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 1 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 1 Medical gas piping (6 +) inlets /outlets 1 3 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -163 Printed: 07 -21 -2008 City ofTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -163 Issue Date: 07/21/2008 Permit Expires On: 01/17/2009 Permit Center Authorized Signature: /! I hereby certify that I have read and �xana governing this work will be complied \wit' Date: al q-4/421 ned this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not presume to give authority to vi • - •r cancel the provisions of any other state or local laws regulating construction or t • - • - .� ance •f work. I am auth•. • ed to si Signature: Print Name: /17I /71->r Ca / /9— e / this plumbing /gas piping permit. 438/ Date: ? )--/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -163 Printed: 07 -21 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2800 SOUTHCENTER MALL TUKW TUTTI FRUTTI FROZEN YOGURT Permit Number: Status: Applied Date: Issue Date: PG08 -163 ISSUED 05/29/2008 07/21/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 12: * ** *PUBLIC WORKS * * ** For the tenant supplied grease interceptor tenant shall follow Westfield's Grease Waste Maintenance Program dated January 30, 2008, copy attached. * *continued on next page ** doc: Cond -10/06 PG08 -163 Printed: 07 -21 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Date: 7 Print Name: P7 l— Z D / e- U ordinances governing or local laws regulating doc: Cond -10/06 PG08 -163 Printed: 07 -21 -2008 i • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ei. tukwila. wa us • Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: K -0305 - South Center Mali Tenant Name: Tutti Frutti Frozen Yogurt Property Owners Name: Westfield Corporation Mailing Address: 11601 Wilshire Blvd. Name: Marcia Peddicord King Co Assessor's Tax No.: 636420 -0010 Suite Numbers Floor: 1 New Tenant: ® .....Yes ❑ ..No Los Angles City Mailing Address: 633 South Center - Trailer #3 E-Mail Address: mpeddicord @us.westfield.com CA state 90025 Zip Day Telephone: cell: 818 -402 -8923 Tukwila. WA 98188 City State Zip Fax Number: Company Name: Next Level Exhibit Design Mailing Address: 4615 NW Neskowin Ave Contact Person: Tom Werner Portland OR 97229 E -Mail Address: tom @nlbd.com City State Zip Day Telephone: 503 - 629 -7400 Fax Number. 503 - 629 -7401 Contractor Registration Number: Expiration Date: Company Name: Mailing Address: Contact Person: E -Mail Address: Architrave Design Team Corp. 7301 Elk cr, #1 Myrian Mahiques Hintington Beach CA 92647 myriam mahiques@hotmail.com Company Name: Mailing Address: Contact Person: E -Mail Address: CSJ Technical Solutions and Services, Inc. City State Day Telephone: 714- 842 -0382 Fax Number: 714- 842 -0382 Zip 4000 Valley Blvd. Walnut, CA 91789 John Jolly, PE QMpp5coliooslPame.Applicattoos 6a tmeu -2006 - Permit Appliationdoe Revue& 9-2006 bb City State Zip Day Telephone: 909 -598 -6067 Fax Number: 909 -598 -6089 Page 1 of 6 0 Valuation of Project (contractor's bid price): $ 0 $55L000 Existing Building Valuation: $ Scope of Work (please provide detailed information): 10 x 20 retail kiosk including 6 x 20 back lit wall graphic and service counters. Will there be new rack storage ❑ Yes M.. No If yes, a separate permit and plan submittal will . quired 4 v, ' . ?a; •t ;- °' `s. 141 timid ". • 13uilath was , y n y, • 0�8,ppa t,-' t aRk* ; >r ytu t` `h t +1 ;4, ;, 7,. tt,t <.)+�} *Sit ►X,: -V.J"� ` x p ; y c t ° t � 7: 4 raExi mg >,i .�t ^s���,'t - !r, .y�'` # l. Ek4.17a,+t :'�ntenbr It o e zg ,g dditlEid�t• ' 5' " � �i,� :pS _ #? ,.5 rew ,`:...,.. st4 ,ft�<" !d ¢, :..., •,,. N� -tr *3M',: f- :gYb a7 J.. yr t.. ,Yie ,, ,1" A't• d� :I = � - _ '. �- �., ,t` ter p ry ".. ; I: } F d l' (�° '` gerIPTYp°�'r", 4? 4.4 R RAJ i i y. _ 9 • , v�rA �y�` t+a s ;, ' gyp• 1 PLANNING DIVISION: Single family building footprint (a - of the foundation of all structures, plus any decks over 18 inch ;; d overhangs greater than 18 inches) — *For an Accessory dwelling, de the fallowing: Lot Area (sq ft): Floor area of principal dwelling: Flo . area of accessory dwelling "Provide documen ••'ton that shows that the principal owner lives in one of the dwellings as his or - mary residence. Number of Parking Sta Provided: Standard: Compact: Handicap: Will there be a clan., in use? ❑ Yes No If "yes ", explain: ❑.......Sprinklers ❑ ....... Automatic Fire Alarm (j' None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If `jres , attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q'Appi uomns -Apyuc i On r du_200b - Permit Appliofiond« arMeat 9.2x06 an Page 2 of 6 1 PLIJMVIBING AND GAS PIPING PERMIT INFORMATION -� 206- 431` -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: TBD Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 3 �, O o U Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Te -re si- MI Fe, J rte,, o -z4 A fl t .cam 164)4_ Building Use (per Int'l Building Code): : 13 Occupancy (per lnt'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: . : . : ..: ; . ` Q t y :.Fixture Type:;:.. :::: . Qty: . Fixture Type: ; : Qty... Fixture Type: ;> .:... - . Qty - Bathtub or combination batb/shower Drinldng fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste 1 Clothes washer, domestic Floor drain % / Sinks 3 Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system —per drain (inside building) Water heater and/or vent 1 Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment / Repair or alteration of drainage or vent piping / Medical gas piping system serving one to five for specific gas Q.MpplicaliansWotnts- Applicatia On Linc 3 -20x6- Permit Application.doc Revise& 94006 eh Page 5 of 6 } 133 e1a410 IA a l iermit$- 'in "tin/ys��,, ap�A'1i(caw�ti t r'h: Y �4rwN7 �` Y S14„y~3yv �•U L.�?L.�Gj .:.: "?v S� J Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review— Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 1 053.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 1_' AUTHORIZED AG Signature: Print Name: ft ✓/ A1 C t Mailing Address: ('Skia% A/'e:- `7 C7 Date Application Accepted: Date: 3</ "Cr/� Day Telephone: c -c '41-1, '1 t' C City state iDate Application Expires: Staff Initials: Q.MppliationctWomu- Appfinsnons On Lmd3 -3006 - Permit Applica6on.Qoc Revised 9.3006 eh Page 6 of 6 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -163 Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/29/2008 Applicant: TUTTI FRUTTI FROZEN YOGURT Issue Date: Receipt No.: R08 -02605 Payment Amount: $536.00 Initials: WER Payment Date: 07/16/2008 10:50 AM User ID: 1655 Balance: $0.00 Payee: KEVIN LEE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1540 536.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000/345.830 360.00 000.322.103.00.0 176.00 Total: $536.00 4919 07/16 9710 TOTAL 536.00 doc: Receiot -06 Printed: 07 -16 -2008 • City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -01843 Initials: JEM Payment Date: 05/29/2008 User ID: 1165 Payee: KEVIN C. Y. LEE Total Payment: 627.80 SET ID: S000001036 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08 -304 EL08 -654 M'8 Eg TOTAL: 566.80 26.00 35.00 627.80 TRANSACTION LIST: Type Method Description Amount Payment Check 1522 627.80 TOTAL: 627.80 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 26.00 000/345.830 601.80 TOTAL: 627.80 2975 05/29 9711 TOTAL 627.80 Doc: RECSETS -06 INSPECTION RECORD Retain a copy with permit INSP ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION f- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: T2r.f i t -rr Type of Inspection: FlkJA 1 �' Address: 2 6(x) w' v' I i Date Called: Special Instructions: Date Wanted: - 7_zLI --48, (4.2 p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: rvr w k c t tc (f►N4- I spe or: Date: 6 .00 REINSPECTIONEE REQUIRED! Prior to inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IA 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 1 Project: /`r°T.Z � 7/77:7_ . Type of Inspection: 1� en // 2 &J /�%G(.9 Address: 2 8'0 m /4 // Date Called: . Special Instructions: Date Wanted: '7 - 22-61° �prr Requester: Phone No: -902.5-- VIApproved per applicable codes. Ij Corrections required prior to approval. COMMENTS: • Inspector: 1J r Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: LIGHT COMMERCIAL GT2700 Grease Interceptor TAG FILE COPY Dimensional Data (inches and [ mrr Permit t to�Manufacturing Tolerances and Change Without Notice rm0 tt a � o. INLET G= WIDTH OF BODY GT2700 =4 through GT2700 -50 RECEIVED GT2700 -75 & GT2700- 10CITY OF TUKIMLA JUL 0 8 2008 PERMIT CENTER Model Number NB Inlet /Outlet No -Hub Flow Rate G.P.M. [L] Capacity Grease Lbs. [kg] Dimension in Inches - - C D/E F G GT2700 -4 2 [51] 4 [15] 8 [4] 10 [254] 7 1/4 [184] 15 7/8 [403] 9 7/8 [251] _ GT2700 -7 2 [51] 7 [26] 14 [6] 11 1/8 [283] 8 1/8 [206] 17 1/4 [438] 11 7/8 [302] GT2700 =10 2 [51] 10 [38] 20 [9] 11 3/4 [298] 8 1/4 [210] 19 1/4 [489] 14 [356] GT2700 -15 2 [51] 15 [57] 30 [14] 13 3/8 [340] 9 3/8 [238] 21 1/4 [540] 16 3/4 [425] GT2700 -20 3 [76] 20 [76] 40 [18] 15 [381] 11 3/4 [298] 24 1/8 [613] 17 1/4 [438] eT2700 =25 ` —r m. 2599441 '50e[23]e 1j'7 [432]as a1r2'112 :[3 &81 z ,r20,41 1[644]k ,19 7/8 GT2700 -35 4 [102] 35 [132] 70 [32] 18 3/4 [476] 14 1/4 [362] 28 [711] 22 1/2 [572] _ _ GT2700 -50 4 [102] 50 [189] 100 [45] 21 1/2 [546] 16 [406] 29 7/8 [759] 24 1/2 [622] GT2700 -75 4 [102] 75 [283] 150 [68] 22 3/4 [587] 18 1/2 [470] 36 [914] 28 5/8 [727] _ GT2700 -100 4 [102] 100 [379] 200 [91] 27 [685] 23 [584] 42 3/4 [1086] 33 5/8 [854] GT2700 Grease Interceptor Recommended for removing and retaining grease from wastewater in kitchen and restaurant areas where food is prepared. Grease trap is corrosion- resistant coated fabricated steel with no -hub connections, flow diffusing baffle, integral trap, and vented inlet flow control device. OPTIONS - JP2700 6 [152] E ion Pfro u/3 APPROVED Sizes 4 - 50 Sizes 20 G.P.M. - 50 G.P.M. ZURN LIGHT COMMERCIAL PLUMBING PRODUCTS • 2640 South Work Street • Falconer, NY 14733 Phone: 1400/906 -5060 o Fax: 716/665 -3126 • World Wide Web: www.zurn.com Rev. A Date: 1/5/05 C.N. No. 84460 Dwg. No. 63802 Product No. GT2700 fu-0. LIGHT COMMERCIAL AINN4f GT2701 Low Profile Grease Interceptor TAG Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice INL G = WIDTH OF BO DY 0 c T F -T Model# Inlet/ Outlet Size** Flow Rate G.P.M. [L] Capacity Approx Wt. Lbs. [kg] Dimension in Inches - Water Gal. [L] Grease Lbs. [kg] C D/E F G GT2701 -20 3 [76] 20 [76] 15 [57] 40 [ 18] 102 [46] 10 [254] 3 1/8 [79] 31 [787] 21 1/8 [536] GT2701 -35 —4T-16-2T 32]° "30'[114]® °70•[321°' 3/4 [273]^ .3a118 [79J •421 /84j,0Za 29..3/84746] GT2701 -50 4 [104] 50 [189] 45 [170] 100 [45] 210 [95] 16 [406] 10 [254] 491 /2 [1257] 29 3/8 [746] GT2701 Grease Interceptor Zurn Light Commercial Acid Resistant Coated interior and exterior fabricated steel low type grease interceptor, rated at GPM and _ _ Lbs. grease capacity, with internal air relief by -pass, bronze cleanout plug and visible double wall trap seal with removable pressure equalizing /flow diffusing inlet baffle, fixed botttom outlet baffle, and visible double wall trap seal. Gasketed non -skid secured cover with center tie down assembly, complete with external flow control fitting. Regularly furnished with low inlet and outlet. APPROVED ZURN LIGHT COMMERCIAL PLUMBING PRODUCTS a 2640 South Work Street o Falconer, NY 14733 Phone: 1- 800/906 -5060 o Fax: 716/665 -3126 o World Wide Web: www.zurn.com Rev. A Date: 9/27/06 C.N. No. 95670 Dwg. No. 63803 Product No. GT2701 ZINN® Engineered GRE SE INTERCEPTORS PURPOSE For nearly a hundred years, grease interceptors have been used in plumbing wastewater systems to permit free flow of drainage from sinks and similar equipment. They have played an important role in preventing grease accumulations from clogging waste pipes and sewer lines. They also help to improve operations at wastewater treatment facilities and prevent environmental problems caused by grease. INSTALLATION Installation Considerations Install the interceptor as close as practical to the fixture(s) being served. The interceptor may be placed on the floor, partially recessed in the floor; recessed with top flush with the floor; or fully recessed below the floor, in order to accommodate piping and structural conditions. Anticipate sufficient clearance for removal of the interceptor cover and baffle for cleaning. Also, take into consideration the possibility of pipelines becoming clogged with congealed grease that may collect before reaching the grease interceptor. Do not install the grease interceptor in a waste line from a garbage grinder. Garbage grinder waste must bypass the interceptor because rapid accumulation of solid matter will greatly reduce the grease interceptor efficiency, preventing operation in compliance with its rated capacity. Solid material should not be permitted to enter the grease interceptor. In an application where solids are present, a solids interceptor should be used. A separate grease interceptor is recommended for each commercial dishwasher. The size of the interceptor is determined by the discharge rate of the dishwasher as specified by the manufacturer. Placement of the interceptor in a high traffic area is an important concern. If the interceptor is to be installed flush with the floor, it is necessary to determine whether or not the interceptor will experience heavy -duty load traffic. The standard grease interceptor is designed for foot and light traffic only. If a greater load rating is required, the interceptor must be constructed accordingly to accept the higher load. Flow Control The use of a flow control device (Z1108), furnished with all grease interceptors, is an important factor in the operation of the interceptor. The flow control device should be installed in the waste line upstream of the grease interceptor. It should be placed beyond the last connection from the fixture(s) and as close as possible to the underside of the lowest fixture. When two or more sinks or fixtures are combined and served by one interceptor, a single flow control fitting can be used. The flow control device must be properly vented to permit air to mix with the fluid entering the interceptor. Air facilitates separation and, more importantly, is necessary to maintain the proper pressure, thus, the proper operating level within the separation chamber. Air intake for the flow control device may terminate under the sink drain board, as high as possible, to prevent overflow or terminate in a return bend at the same height outside of the building. When a fixture is individually trapped and back - vented, air intake may intersect the vent stack. All installation recommendations are subject to approval of code authority. Venting Grease interceptors must have a vented waste, sized in accordance with code requirements for venting traps, to retain a water seal and to prevent siphoning. Multiple Fixture Installation One interceptor to serve multiple fixtures is recommended only where fixtures are located close together. In such installations, each fixture should be individually trapped and back - vented. MAINTENANCE General Considerations Design and installation are key factors to the operation of a grease interceptor. However, without disciplined maintenance, most performances are lost. For a manual interceptor to perform as designed, a strict maintenance schedule must be adhered to. If adequate maintenance is not performed, excessive grease buildup will occur until water ladened with grease passes directly through the unit. Therefore, no matter how efficient the design or how proper the installation, grease interceptors perform only as well as the maintenance routine allows. Cleaning All grease interceptors must be cleaned regularly. The frequency of grease removal is dependent upon the capacity of the inter- ceptor and the quantity of grease in the wastewater. Grease removal intervals may therefore vary from once a week to once in several weeks. When the grease removal interval has been determined for a specific installation, regular cleaning at that interval is necessary to maintain the rated efficiency of the interceptor. After the accumulated grease and waste material has been removed, the interceptor should be thoroughly MAINTENANCE, continued checked to make certain the inlet, outlet, and air relief ports are clear of obstructions. Cleaning can easily be performed by following the steps listed below: 1. Loosen and remove the fastener(s) securing the cover to the interceptor body. 2. Remove the cover. 3. Remove the flow diffusing baffle and /or sediment tray assembly from the body. 4. Wipe down the baffle assembly, disposing of grease in a proper waste container. GENERAL PRODUCT INFORMATION Typical Zurn Grease Interceptor In a Zurn Grease Interceptor, the static water level is at the bottom of the outlet. Any piping into the interceptor below this elevation will remain filled with water. Odor from accumulated grease in an interceptor may pass back through the piping system and through the drain opening. An additional trap should be considered between the fixture and interceptor. Consult local codes. All Zurn Interceptors are 100% steel construction, coated with a white acid resisting epoxy (A.R.C.). Z1170 Series Interceptors are certified by the Plumbing and Drainage Institute (POI). Zurn Grease Interceptors are listed by the International Association of Plumbing and Mechanical Officials (IAPMO): Variables Affecting Grease Interceptor Performance 1. Velocity of Incoming Water A higher velocity of water will contribute to a more turbulent mixture. This will slow the grease separation process, thereby reducing efficiency. Recommended Solution — Install additional flow control fittings at all sources of flow. 2. Ratio of Grease to the Water The higher the ratio of grease particles to the water, the lower the efficiency of the interceptor. Recommended Solution — Increase the size of the interceptor. 3. Specific Gravity (Weight) of the Filtrates Grease has a lower specific gravity than water and will rise to the surface quickly. Grease - ladened food particles having a higher specific gravity than water will linger and accumulate at the bottom, eventually passing out of the interceptor. Recommended Solution — Install a solids interceptor at the source of solid particles, prior to the grease interceptor. 5. Clean out any liquid grease by skimming it from the top surface. Remove any remaining solid material with a spade or shovel. 6. Remove the clean -out plug on the outlet portion of the body. Using a clean water supply, hose down and wipe the inside of the body. 7. Replace the cleaned baffle assembly back into the unit. 8. Ensure that the cover gasket material is intact and in good working condition. Replace gasket material if it is damaged. 9. Securely refasten the cover and the clean -out plug back onto the trap. Old Style New Style GASKET FLUSH TOP COVER AIR - RELIEF BY -PASS NO OBSTRUCTIONS PRESSURE EQUALIZING & FLOW DIFFUSING BAFFLE NLET G = WIDTH OF BODY OUTLET 4. Possible Presence of Detergents in the System Grease - cutting detergents will break the liquid grease into minute particles that can cause these liquids to pass through the interceptor. Recommended Solution — Increase the size of the interceptor. 5. Percentage of Maximum Flow Capacity If the maximum recommended flow is exceeded, the efficiency of the interceptor will decrease considerably. Recommended Solution — Install additional flow control fittings at all sources of flow. 6. Location of Grease Interceptor The interceptor should be located as close as possible to the source of grease. Waste pipes leading to the grease interceptor may become clogged if liquid cools prior to entering the grease interceptor. GENERAL PRODUCT INFORMATION, continued Need for a Flow Control Device A grease interceptor, correctly designed to separate Tight density substances from wastewater, will not by itself govern or regulate the flow of water through the inter- ceptor at all times to sufficiently assure the "flotation" separation of the substances which are to be intercepted at maximum efficiency. The flow control fitting is designed with an integral orifice to give a predetermined optimum flow rate, thus eliminating turbulence in the interceptor, which could otherwise occur from sudden surges in the drainage line. The orifice openings are related to the size and flow rating of the grease interceptor. Standard orifice sizing is for gravity flow conditions where no pressure buildup is considered: If an interceptor is operating at maximum flow levels, a head may develop, in which case overload conditions may still exist. Trap Flow Rate Size /GPM Standard Size Orifice /Inches 4 5/8 7 5/8 10 15/16 15 _15/16 20 1 -1/4 25 1 -1/4 35 1 -1/2 50 1 -3/4 75 2 -1/4 100 2 -1/4 125 2 -5/8 150 _2 -5/8 200 _ 3 =1/4 250 3-1/4 300 4 400 4 -1/2 450 4 -7/8 500 4 -7/8 211081 1108 -L Flow Control Fitting Every interceptor should have a flow control fitting and flow control fittings should be properly vented. The flow control fitting is installed in line between fixture and interceptor. Its function is to regulate the flow so that it will not exceed the flow rate capacity of the interceptor, thus ensuring fool -proof operation and maximum efficiency. *Orifice size varies according to size of interceptor. Z1108 Dimensional Data A (IP) B C D 1 -1/2 5 -7/16 2 -7/8 3 -13/16 2 5-7/16 3 -3/8 3 -13/16 3 6 -1/8 4 4 -1/8 4 6 -13/16 5 4 -3/4 Z1108 -L Dimensional Data NUT A B C D 1 -1/2 5 -3/4 3 -3/8 1 -7/16 2 5 -3/4 3 -3/8 1 -7/16 3 6 -3/8 3 -3/4 2 -3/4 4 9 -1/8 5 -1/4 5 -1/4 Settings for Zurn Flow Control Fitting Consider a Z1170, #300 Interceptor, rated at 10 GPM, installed with the Z1108 or Z1108 -L flow control fitting. When installed with a scullery sink in compliance with PDI standards for grease interceptors, this Interceptor can be recessed in the floor (shown solid) or placed on the floor (shown dotted). Maximum distance in inches from bottom of sink to centerline of flow con- trol fitting inlet (D). Important Check size of Interceptor to determine setting as indicated below. 'H' SINK INTERCEPTOR SIZE DEPTH 100 200 300 400 500 600 700 800 '0' Dimensions in Inches 6 7.5 6.5 _ 7.5 10 10 10 7 6.75 7.5 10 10 10 7.5 6.75 7.5 9.25 9.25 9.25 8 _6.0 6.75 9.25 9.25 9.25 8.5 6.75 8.5 8.5 8.5 9 6.0 8.5 8.5 8.5 9.5 7.75 7.75 7.75 _ 10 7.75 7.75 _ 7.75 10.5 7.0 7.0 7.0 10.0 10.0 11.0 11 7.0 7.0 7.0 10.0 10.0 11.0 11.5 6.5 6.5 6.5 9.25 9.25 10.5 12 9.25 9.25 10.5 12.5 8.5 8.5 9.5 13 8.5 8.5 9.5 13.5 7.75 7.75 9.0 14 7.75 7.75 9.0 14.5 7.0 7.0 8.0 15 7.0 7.0 8.0 15.5 5.0 5.0 7.5 16 7.5 18 5.75 NOTE: All figures represent maximum distances in inches. Figures between horizontal lines are recommended. GENERAL PRODUCT INFORMATION, continued Z1173 Ejectomatic Typical Installation To simplify the cleaning process and prevent grease from clogging drainage lines, Zurn has developed the Ejectomatic Greaseptor. This unique unit is provided with a skimming tray which retains the accumulation of grease. Cleaning simply becomes a matter of discharging hot water through the Greaseptor. The resultant heat liquifies the grease, which is then ejected through the nozzle at the turn of the handle. The ejected grease may be collected in a bucket or other container for easy disposal. Any water that may enter the tray is directed back into the intercepting chamber by means of a water dis- charge port incorporated into the design of the skimming tray. 1. The manual draw -off valve reduces the frequency that the cover of the interceptor must be removed during the cleaning process. 2. Grease is removed from the interceptor by means of the Ejectomatic valve located on the outlet end of the interceptor. 3. To remove grease from the interceptor, hot water is first run through the unit to liquefy the grease. The water flow is then shut off and the draw -off valve is opened, allowing the grease to gravity -flow out of the interceptor. When no grease is present, the valve is then closed. 4. The grease layer that forms on top of the water must build down to reach the level of the Ejectomatic valve. If water is coming from the valve, then the interceptor has not yet reached its capacity for cleaning. 5. If grease is present when the valve is opened, this ejected liquid grease can be collected for proper disposal. 6. Frequency of grease draw -off is established experimentally. Some installations may require drawing off grease daily, while others periodically. 7. Solids and food waste should not be allowed to accumulate in the interceptor. This will impair the operation of the unit and cause reduced efficiency. Check the interceptor for solids and clean manually as required. INLET G = WIDTH OF BODY OUTLET J Z1174 Grease Eating Bacteria Dosing Unit To keep the grease interceptor operating in optimum condition, it is recommended that the Z1174 automatic bacteria dosing unit is used on a regular basis. The dosing unit delivers to the interceptor an engineered microbial blend that degrades grease, fats, proteins, and carbohydrates. The added bacteria does not transfer the grease downstream; however, it degrades and digests the grease inside of the unit. This environmentally TO ORMN LINE OF SINK OR 01SHWASHER NOTE; FURNISHED ABY ND OTHE CONNECTORS VENT 1 MINI*1 . � 2 -1108 FLOW CONTROL 2 -1 I8 SOLOS NTERCEPTOR INLET friendly formulation reduces the production of foul odors that can emit from inside the interceptor and drain lines. The Z1174 liquid bacteria contains no harmful caustic elements and won't damage the interceptor or drain piping. It is specifi- cally engineered to degrade only the agents for which it was developed. As a result, this bacteria concentrate gives full protection to interceptors and related waste piping systems. PROGRAMUABLE PUMPING UNIT G - WIDTH OF BODY ZURN. OUTLET CONTAINER UOUID BACTERIA ZURN PLUMBING PRODUCTS GROUP SPECIFICATION DRAINAGE OPERATION 1801 PITTSBURGHAVE., ERIE, PA, U.S.A. 16512 PHONE. 814 /455 -0921 FAX: 814/454 -7929 WEBSITE: www.zurn.com Form No. SD10, 8/02 121 1— M OBILE 192,6 sit , 610 249sf PRETZEL JV 180s f TUTTI E FRUIT CI L4 Cf) 01 Cr) 1-1) J LCD_ CD. 01 3 6 696 180sf OBALiCOL S 8Osf 0 Lu 01 r2. Pew-171E1Mb, cc, i (r) ,-_ , .• 0,..- „,...1cr ;',..1...-1) ' fil 1.- •,......,., r t1-11*„.177,::3 (71 7' r,:.): udr:,., -' - -' - ''Cr :1 C FR E. COPY _J. LLJ U (i) LF= VEILS 174,,630sf 110' - 6," 10' = 1" 7 4'- 6 " 1 RECEIVED JUL, 01 NM TUOVILA _PUSLILINOBKS, 0'- 2'-6)") 1 11 14 71111114 up T.0' July 8, 2008 Mr. Robert Benedicto Building Official City of Tukwila Department of Community Development 6300 Southcenter Boulevard Tukwila, WA 98188 -2544 neeeveD JUL 0 8 2008 pERma cEN-rEh RE: Request for Overtime Plan Review ( 0 $ — (4,3 Tutti Frutti Kiosk, 2800 Southcenter Mall #K -0305, Tukwila, WA 98188 Dear Mr. Benedicto: To expedite the plan review process, please use this letter as my formal request to utilize the overtime plan review procedure at the City of Tukwila. I understand that the cost of this service is 1.5 times the standard hourly rate and I will be billed for a minimum of four hours. I agree to review and respond to any and all plan comments in an expeditious manner in order to keep the plan review process moving quickly. I will assume all payment for the overtime plan review. Said cost will be accumulated during the plan review process and when the plans are approved, the City of Tukwila will require that the overtime cost be paid on or before the building permit and approved plans are picked up. I request that this overtime review process be initiated immediately for this set of plans only. Sincerely, Cc: Tenant file Josh Kimmel Southcenter Field Tenant Coordination Dear Andrew, Baker Commodities Inc. would like to thank you for consideration or our company. Our goal is to provide the best possible service for your grease trap needs. As per our conversation we can schedule and maintain all of your new locations needs. Services for the grease traps will include: • Removal of All Waste from the grease traps. • All waste is pumped into a holding tank on our trucks and then brought back to our plant for onsite recycling: • If trap'is too far from the truck we use a portable pumping system. • This system is then wheeled back to the thick and pumped into our holding tank. • The grease traps will be backfilled after cleaning to insure proper draining. • Baker Commodities Inc. does not use, sell, handle, or recommend the use of chemicals and /or "bio- degradable" products.. • Please advise the restaurant owners that you do not want these types of product used. • An inspection and service report will be left at each location. • Customers will be required to provide a regular cleaning schedule, • All customers will be contacted prior to each service. • Westfield will be included with a copy of the services by e-mail or fax. If you have any question or concerns please do not hesitate to give us a call @ 206 - 243 -7387 Thanks, Jim Hodge Baker Commodities Inc. Seattle Division RECEIVED CITY OF TUKWILA JUN 2 6 /UM PERMIT CENTER BAKER COMMODITIES INC. _QaaGly_nad IN14...Weddwide - - - P.O. Box 58368. Seattle. WA 98138 (206) 243 -7387 FAX (206) 243-3412 CORRECTION Wsifie[if Southcenter E;AS T P AIN TERK C ROGRAc gin PURPOSE: The intent of this program is to provide maintenance guidelines for any new food -use retailer utilizing a grease trap in place of a grease interceptor so as to minimize health, safety and environmental concerns. POLICY: All new retailers utilizing a grease trap in place of a grease interceptor will be required to contract the services with a Landlord- required grease waste contractor. Each store will have their grease trap maintained (as per the details below) a minimum of every two months. Proof of service should be kept on -site as well as copied to the mall management office (directly from the contractor). There shall also be placed on -site (and available at Landlord's request), a grease trap maintenance log which the contractor will complete upon each bi- monthly service. PROCEDURE: Below is the procedure for grease trap cleaning and recycling to be provided by a required vendor (see sample proposal attached): 1. Removal of all waste from grease traps. 2. Contractor will utilize a portable pumping system when necessary. 3. The grease traps will be backfilled after cleaning to insure proper draining. 4. Contractor will not use any biodegradable or chemicals that might temporarily break up grease but lead to re- coagulating later on. 5. An inspection and service report will be left at each location. 6. Customers will be required to provide a regular cleaning schedule. 7. All customers will be contacted prior to each service. 8. Westfield will be included with a copy of the services by email or fax. COMPLIANCE Fines will be levied for non - compliance. If our Maintenance Engineers or contracted vendor is denied access to the space during the scheduled removal or during an emergency removal, a $100 fine for each instance will be levied for each occurrence. Retailer Name: Grease Trap Log Space Number: Contractor Signature 1 Repairs /Remarks, Amount of Grease Removed Date - r June 5, 2008 • Cizj' of Tukwila • Jim Haggerton, Mayor Department of Community Development Marcia Peddicord 633 Southcenter Mall, Trailer #3 Tukwila, WA 98188 RE: CORRECTION LETTER #1 Plumbing /Gas Piping Application Number PG08 -163 Tutti Frutti Frozen Yogurt — 2800 Southcenter Mall, #K -0305 Dear Ms. Peddicord, Jack Pace, Director This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time the Building Department has no comment. Public Works Department: Joanna Spencer at 206 - 431 -2440 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, &at kiNA- Brenda Holt Permit Coordinator encl xc: File No. PG08 -163 P:\Permit Center \Correction Letters \2008\PG08 -163 Correction Ltr i 1.DOC wer A2/I/) Cnrrthnnnter Rnnlon�nel Clrite 41/11) a 7111.1.a bs TIf 1)h.., #,.., 11121 DD a Di..,..... 9/I4( A91 9/.71) .. L'..... 9/1A 491 9A. C 1 • • PUBLIC WORKS DEPARTMENT COMMENTS DATE: June 04, 2008 PROJECT: TuTTi FRUTTI FROZEN YOGURT 2800 Southcenter Mall, K -0305 PERMIT NO: PG08 -163 PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. 1) Please submit spec /cut sheet for proposed grease trap /interceptor unit. 2) Show on your plan where this unit is going to be installed. P: joanna/comments 1 PG08 -163 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -163 DATE: 07 -8 -08 PROJECT NAME: TUTTI FRUTTI SITE ADDRESS: 2800 SOUTHCENTER MALL, #K -0305 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS: B I � g Divisio� J Fire Prevention Planning Division E Public Works ❑ Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete I I DUE DATE: 07 -10 -08 Not Applicable ❑ r.."..enter,U e'Ori'Iti • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Al Structural Review Required I I No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08 -7 -08 Approved 1 Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit.Center Use, Ofly . • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 • PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -163 DATE: 06 -26 -08 PROJECT NAME: TUTTI FRUTTI FROZEN YOGURT SITE ADDRESS: 2800 SOUTHCENTER MALL, K -0305 Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division n Public Worls �l b Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 07 -01 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07-29-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 r PERMIT COORD COPY al PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -163 DATE: 05 -29 -08 PROJECT NAME: TUTTI FRUTTI FROZEN YOGURT SITE ADDRESS: 2800 SOUTHCENTER MALL, K -0305 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Pu4 Works [D —LI'-' Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n Comments: DUE DATE: 06-03-08 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07 -01-08 Approved Approved with Conditions n Not Approved (attach comments) 11 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 6$6.--tobi Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW LVJ Staff Initials: �� Documents/routing slip.doc 2 -28 -02 PROJECT NAME: TEAM WIC PERMIT NO: ' 1,(13 SITE ADDRESS: NOD 7t ktka � lt- D ?2L ORIGINAL ISSUE DATE: NV REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF IN TIALS 1 o -.0a- o 0q-lii_1'c Sununary of Revision: Wttk Old oL- SINK ( 1-tErint 5Pi''c, itieSr Received i3 y2 1 r Gct REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7 k 7 Plan ChecWPermit Number: PG O -- j e,3 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # RECEIVE Pm' OF r! j Revision # I after Permit is Issued JUL 0 8 2008 ❑ Revision requested by a City Building Inspector or Plans Examiner PERftNITCENTER Project Name: TtA -t f " 1 V r to +fi - 1:;"45J--- Project Address: 2CCP-v So 4 IA c �., 4,• T � 11 it �< -636S - Contact Person: n'14,-G'� ; j 2 Phone Number: Pf 8' - 4 Z - F-123 Summary of Revision: -E-4 S-i n its r . zr � el 4- tied, ( #/ f r .9.,,g-- T . _ , +- I.t, ; 11 b e- u' 11-J, i l _ eJ1 -- - rn.crp n l� , Sheet Number(s): P % P Z "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 1 tif Entered in Permits Plus on Pi fR4J iapplications\fonms- applications on linelrevision submittal Created: 8 -13 -2004 • City of Tukwila Steven M Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 =3665 Web site: http: //www.c.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: W;6.70 Plan Check/Permit Number: P6 Og' - ❑ Response to Incomplete Letter # _ El— Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name:Ltj Project Address: 24W ' S�u•/h0_ /e': 1/ rjo3d5__ Contact Person: `na.- ' Pedd;` Phone Number: a-e) / Summary of Revision: ea 71Y 5p ec— s/ eel' Ai( 7- 6 -A ee i s 1reYvi d'=?--k- • -- - RECE JUN 2 6 1008 RERMITCENTER P(5 rte; / 1 t4" r5 747, he ;,7,5/,, lf� Ere s.e //IQ -g le— M , e L av �l V 5 k �l r5 7 e /rr e.e SGi/ e �t o pro t/ - Sheet Number(s): P / P 2- "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: gEntered in Permits Plus on 6e (, 2--it \applications\forms- applications on Iine\revision submittal Created: 8 -13 -2004 King County Department of Natural Resources and Parks Wastewater Treatment Division Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type — 6O34+5 & 144//cet -c 444 1 / Property Street Address `TA l &. A— q / fg ZIP City State ji�i i�r ai os�- Owner's Name Subdivision Name Lot # Subdiv. # ll y� Block # Building Name (if applicable) (ter, tc ) ass — i 12 � 14»fro L Pe— Owner's Phone Number (with Area Code) Property Contact Phone Number (with Area Code) Owner's Mailing Address Property Tax ID # 4.2-1) - 0. 6 Party to be Billed (if different from owner) City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre- existing building on this property. Credit for a demolition may be given under some circumstances. Demolition of pre- existing building? ❑Yes No Was building on Sanitary Sewer? ❑ Yes ,No Was Sewer connected before 2/1/90? ❑ Yes No Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? ❑ Yes ❑ No A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 Sink, Clinic flushing 8 8 Sink, kitchen 3 2 .. 4) Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 Water closet, tank or valve, >1.6 GPF 8 4 Total Fixture Units I 4 Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units 20 r 3 RCE B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) 187 C. Total Residential Customer Equivalents: (add A & B) U A B o.3 0 RCE RCE CITY OF TUKWILA MAY 2 9 2008 PERMIT CENTER Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capaci deviation will require resubmission of c• cted •> a for determination A Signature of Owner /Representative harge levied will be based on this information and any evised capacity charge. Print Name of Owner /RenraRantativp. NI1 -rqe; i H %'ter D7) Date Untitled Page • 1 General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. DENNIS THE PLUMBER Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company DENNIS THE PLUMBER 2538621241 107 EAST 3RD CLE ELUM WA 98922 KITTITAS INDIVIDUAL UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 602372292 ACTIVE DENNIP *965DJ CONSTRUCTION CONTRACTOR 3/2%2004 3/14/2010 DENNIP *196C6 PLUMBING UNUSED Business Owner Information Name Role Effective Date Expiration Date O'BRIEN, JAMES R OWNER 03/11/2004 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC 608652 01/14/2004 Until Cancelled $6,000.00 03/02/2004 Insurance Information Page 1 of 1 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 TRUCK INS EXCHANGE 034718024 01/14/2007 01/14/2009 $2,000,000.00 11 /29/2007 1 TRUCK INS EXCHANGE 034718024 01/14/2004 01/14/2007 $1,000,000.00 12/15/2005 https: // fortress .wa.gov /lni/bbip/Detail. aspx ?License= DENNIP *965DJ 07/21/2008 PLUMBING FIXTURE SCHEDULE SYMBOL MANUFACTURER/ MODEL NO. DESCRIPTION HW CW W V SUPPLY TRIM WASTE TRIM REMARKS WORLD TSS -1--H HAND SINK 1/2" 1/2" 2" 1 1/2" - -- - I GREEN GREEN WORLD TSA --3 -D1 3 -COMP SINK 1/2" 1/2" 2" 1 1/2" - - - ID GREEN WORLD TSA- 1- -12 -L1 PREP. SINK 1/2" 1/2" 2" 1 1/2" - _ - D MOR- -PLO AMERICAN FSC52 WATER HEATER 3/4" 3/4" - - - - 109 GALLON PER HOUR RECOVERY RATE AT A 90F TEMPERATURE RISE. 24KW HEATING a - Cl ZURN GT2700 -25 0 GREASE TRAP _ - 3 " 2 ZURN MODEL GT2700 -25 WITH ZURN Z1108 FLOW CONTROL DEVICE. 25 GPM, GREASE CAPACITY IS 50 LBS. 3" INLET AND OUTLET CONNECTIONS. Allik Mir 0 v 0 0 0 W Nf7 0 o m � A n en 0 0 a O N - 0 - N o 1§ m(f) o 0. 03 b in N 0 - ° o o a Q IN THE EVENT ISSUES WITH PIPE CLEARANCES AND HEIGHTS OCCUR, USE THE LOW PROFILE GREASE TRAP ZURN MODEL GT2701 -355 AS AN ALTERNATE TO THE GT2700-25. THE GT2701 -35 HAS 4" INLET AND OUTLET CONNECTIONS. ITEM NO HS-1 S -2 S---1 WATER HEATER SIZING CALCULATION DESCRIPTION HAND SINK PREP SINK 3 COMPARTMENT SINK (110 x 0.85) = 93.5 GPH 93.5 GPH X 90'F X 8.33 0.9 QUANTITY X FLOW = SUB TOTAL. 1 1 1 DEMAND FOR 140'F HOT WATER 77885.5 BTUH = 77885.5 BTUH / 3413 kW/ BTUH = 22.8 kW X 5 = 5 GPH X 45 = 45 GPH X 90 = 60 GPH TOTAL = 110 GPH PLUMBING FLOOR PLAN 4 SHEET NOTES 1. PIPES SHOWN OUTSIDE OF WALL FOR CLARITY. 2. ALL PIPING IS UNDER THE FINISHED FLOOR OR CONCEALED INSIDE CASEWORK. 3. FLOOR MOUNTED GREASE TRAP TO BE LOCATED UNDER 3 COMPARTMENT SINK. 4. VERIFY LOCATION OF EXISTING WASTE AND VENT PIPING IF POSSIBLE PRIOR TO MARKING OR SAW CUTTING THE SLAB. COORDINATE PIPE ROUTING AND DEMOLITION WITH THE ARCHITECT. CONSTRUCTION NOTES NOT USED 3 /4 "CW & HW DN TO WITH -1, COMPLETE WITH SHUT -OFF VALVES. REFER TO DETAIL 1/P 2. 1 /2 "CW & HW DN, 2" VENT UP, 2" WASTE DOWN TO GREASE TRAP. 1 /2 "CW, 1/2" HW, 2 "W DN, 1 1/2"V UP. 3" VENT TO POINT OF CONNECTION AT 3" VENT PROVIDED BY THE MALL 3 "W AND 3 /4 "CW. CONNECT TO (E) 4" WASTE AND i COLD WATER LINE PROVIDED BY THE MALL CONTRACTOR TO FIELD VERIFY EXACT LOCATION. PROVIDE AND INSTALL NEW GREASE TRAP BELOW THE THREE COMPARTMENT SINK. REFER TO DETAIL 2/P -2. FOR SIZING CALCULATIONS REFER TO DETAIL 3/P -2. CONNECT 3" OUTLET PIPING TO THE SANITARY DRAIN, 2" VENT OUTLET PIPE TO BUILDING VENT SO THE GREASE TRAP IS NOT SIPHONED. COORDINATE ROUTING OF WASTE PIPING FROM THE 3- COMPARTMENT SINK AND PREPARATION SINK TO THE INLET OF THE GREASE TRAP TO ENSURE THAT THERE IS SUFFICIENT FALL AND THAT THE PIPES DO NOT CONFLICT WITH THE SINK LEGS OR LEG BRACING. MATERIAL SCHEDULE A. WATER PIPE -- TYPE 'L' COPPER WITH WROUGHT COPPER FITTINGS AND "NO-LEAD" SOLDER. C. B. ALL HOT WATER PIPING SHALL BE INSULATED WITH INSULATION HAVING AN R- -VALVE OF 4.0 SEWER AND VENT PIPE - BELOW AND ABOVE GRADE INSIDE BLDG. SERVICE WEIGHT (HUBLESS) CAST IRON SOIL PIPE AND STAINLESS STEEL COUPUNGS. D. CONDENSATE DRAIN PIPE - TYPE 'M' COPPER W/ "NO -LEAD' SOLDER. E. SUPPORT PIPING WITH CLEVIS OR SPLIT RING TYPE PIPE HANGERS. "PLUMBERS TAPE AND WIRE" NOT PERMITTED. F. GAS PIPE - SCHEDULE 40 BLACK STEEL WMTT-T MALLEABLE IRON FITTINGS. PLUMBING GENERAL NOTES 1. THE PLUMBING SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL CONFORM TO THE 2006 EDITION OF THE UNIFORM PLUMBING CODE (IAPMO) AND LOCAL CODES AND AUTHORITIES HAVING JURISDICTION. 2. PLUMBING QUALITY AND WEIGHTS OF MATERIALS, ALTERNATE METHODS OF CONSTRUCTION SHALL CONFORM TO CHAPTER 3 OF THE 2006 UNIFORM PLUMBING CODE. 3. CONTRACTOR SHALL COORDINATE ALL WORK SHOWN ON THESE DRAWINGS AND SPECIFICATIONS WITH ALL DISCIPLINES AND TRADES PRIOR TO SUBMITTAL OF BID AND INSTALLATION OF SYSTEM. 4. ALL PLUMBING FIXTURE LOCATIONS ARE DIAGRAMMATIC AND CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR HANDICAP FIXTURES, EXACT LOCATIONS, MOUNTING HEIGHTS AND COLOR. 5. ANY DEVIATIONS FROM THE DRAWINGS OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER PRIOR TO INSTALLATION. 6. THESE DRAWINGS DO NOT INCLUDE ALL NECESSARY SAFETY REQUIREMENTS. CONTRACTOR TO COMPLY TO SAFETY REQUIREMENTS SET FORTH BY THE LOCAL AUTHORITIES HAVING JURISDICTION. 7. CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTAL OF BID AND FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS. SUBMITTAL OF BID WILL VERIFY THAT THE CONTRACTOR HAS VISITED THE SITE. 8. TRAP PRIMERS FOR FLOOR DRAINS AND FLOOR SINKS TO BE INSTALLED AS PER THE 2006 UPC AND THE LATEST EDITION OF THE AMERICAN SOCIETY OF SANITARY ENGINEERING (ASSE 1010) SIZING AND INSTALLATION REQUIREMENTS. 9. ALL SERVICE WATER HEATING EQUIPMENT TO BE IN COMPLIANCE WITH THE MODEL ENERGY CODE. REQUIREMENTS AND LABELED. 10. CONTRACTOR TO REFER TO PLUMBING FIXTURE SCHEDULE FOR INDIVIDUAL WASTE, VENT & WATER CONNECTIONS AT EACH PLUMBING FIXTURE. 11. ALL HOT & COLD WATER PIPING TO BE INSULATED AS PER UPC CODE REQUIREMENTS: PIPE SIZE INSULATION THICKNESS INSULATION VALUE 1/2 " -1" r R =4.0 1 -1/4" - 4" 1 -1/2" R = 4.0 12. TEST SYSTEM(S) IN ACCORDANCE WITH REQUIREMENTS OF THE GOVERNING AUTHORITIES. 13. STEEL PLATE SUPPORTS FOR ALL WALL FIXTURES: SUPPORT WITH 3/8" THICK x 8" HIGH STEEL PLATES RECESSED AND BOLTED TO STUDS AND TAPPED FOR FIXTURE BOLTS. LENGTH OF PLATE AT LEAST ON STUD BEYOND FIXTURE, UNLESS CARRIERS ARE SPECIFIED. 14. ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOID INTERFERENCE WITH ELECTRICAL AND MECHANICAL EQUIPMENT AND STRUCTURAL FRAMING. 15. VERIFY EXACT LOCATIONS, AND SIZE OF ALL PIPING TO WHICH CONNECTIONS ARE REQUIRED. COORDINATE ALL CONNECTIONS WITH THE OWNER'S REPRESENTATIVE 16. ALL CLEAN OUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE AND LOCATED AS PER CODE REQUIREMENTS. THE CONTRACTOR SHALL COORDINATE ALL CLEAN OUT LOCATIONS WITH EQUIPMENT, CABINETS, ETC., AND THE ARCHITECT PRIOR TO ANY INSTALLATION. 17. ALL PLUMBING FIXTURE VENTS TO TERMINATE A MIN. OF 12 INCHES FROM ANY VERTICAL SURFACE AND 10 FEET FROM OR TERMINATED 3' -0" ABOVE ANY OUTSIDE AIR INTAKES. 18. ALL PIPING DISCHARGING INTO FLOOR -SINKS AND /OR FLOOR- DRAINS TO HAVE A MIN. AIR -GAP AS REQUIRED BY LOCAL CODES. 19. ALL VALVES, UNIONS, ETC. TO BE SAME SIZE AS UNE SIZE UNLESS OTHERWISE INDICATED ON DRAWINGS. 20. UNIONS SHALL BE PROVIDED AND INSTALLED AFTER EACH SCREW -TYPE VALVE AND PRIOR TO EQUIPMENT CONNECTIONS. 21. ALL EQUIPMENT SHALL. BE LATERALLY SUPPORTED IN ALL DIRECTIONS TO RESIST A LATERAL MOVEMENT. 22. BEFORE FABRICATION OR INSTALLATION, THIS CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF ALL MECHANICAL EQUIPMENT AND EQUIPMENT PROVIDED UNDER ANOTHER SECTION OF SPECIFICATIONS. EXACT ROUGH -IN LOCATIONS AND REQUIREMENTS SHALL BE COORDINATED IN FIELD. 23. NO PIPING SHALL BE DIRECTLY EMBEDDED IN CONCRETE OR MASONRY WALLS OR FOOTING. 24. THE PLUMBING CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS FOR ALL POINTS OF CONNECTION WITH THE GENERAL CONTRACTOR AND OTHER TRADES PRIOR TO BID. 25. ALL WASTE AND VENT PIPING SHALL SLOPE AT 2% UNLESS OTHERWISE INDICATED. 26. ALL VALVES, TRAP PRIMERS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON- ACCESSIBLE CLINGS SHALL BE INSTALLED BEHIND AN ACCESS PANEL 27. ALL HORIZONTAL PIPING LINES EXTENDED AND CONNECTED TO EQUIPMENT SHALL BE RUN AT THE HIGHEST POSSIBLE ELEVATIONS AND NOT LESS THAN 6 ABOVE THE FLOOR TO PROVIDE CLEARANCE FOR CLEANING. AT WALL OR COLUMN LOCATIONS, PIPING ROUGH -IN SHALL BE STUBBED IN WALLS WHENEVER POSSIBLE 28. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH AND BE CONSIDERED TO BE A PART OF SEPARATE AND COMPLETE MECHANICAL SPECIFICATION. 29. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING ALL AREAS WHICH ARE EXCAVATED AND /OR DAMAGED BY HIS OPERATIONS. IN ADDITION, THE CONTRACTOR SHALL RESTORE TO THEIR ORIGINAL CONDITION ALL AREAS DAMAGED BY HIS OPERATIONS. 30. ALL CONNECTIONS TO EXISTING SERVICES SHALL BE MADE SUCH THAT INTERRUPTION TIME WILL BE AS SHORT AS POSSIBLE. THE CONTRACTOR SHALL GIVE THE OWNER'S REPRESENTATIVE SUFFICIENT NOTICE OF SUCH INTERRUPTION AND THE ACTUAL SHUTDOWN TIME SHALL BE AT A TIME DESIGNATED BY THE OWNER'S REPRESENTATIVE. 1. ALL PLUMBING FIXTURES SHALL HAVE EASILY ACCESSIBLE SHUT -OFF VALVES. 2. ALL HOT WATER PIPES AND DRAIN PIPES EXPOSED BELOW HANDICAPPED LAVATORIES SHALL BE WRAPPED WITH INSULATION. SYMBOL - -V- �-IDW SW 101 111111 Da FIXTURE TYPE ID NUMBER LEGEND SOFT WATER PIPE PIPE DROP SHUT-OFF VALVE DESCRIPTION (E) COLD WATER SUPPLY PIPE COLD WATER SUPPLY PIPE HOT WATER SUPPLY PIPE (E) SANITARY SEWER PIPE SANITARY SEWER PIPE VENT PIPE BELOW GRADE VENT PIPE ABOVE GRADE INDIRECT WASTE PIPE PIPE RISE F EVISIONS No changes shall be nr ade to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions wi I require a new plan submitta may include additional plan review fees. VALVE IN PIPE DKr w A PRESSURE REDUCING VALVE BALANCING VALVE CONTROL VALVE CHECK VALVE WALL CLEAN OUT FLOOR DRAIN FLOOR SINK WITH 1/2 GRATE POINT OF CONNECTION PLUMBING EQUIPMENT TAG WATER PIPE SIZING CALCULATIONS STA11C WATER PRESSURE AVAILABLE BASED ON A FIRE HYDRANT PRESSURE REPORT PROVIDED BY THE WESTFIELD MALL IS 60 PSIG + /--. TOTAL FIXTURE UNITS ALLOWANCE = 10 (8 GPM) BASED UPON 2006 U.P.C. TABLE 6 -4 AND APPENDIX 'A'. STA11C (0.43 X 10' LIFT) RESIDUAL PRESSURE AT LAST FIXTURE TOTAL LOSSES PRESSURE LEFT OVER FOR PIPING LOSSES: DEVELOPED LENGTH: 100' FEET TO LAST RISER + 50% FOR FITTING LOSSES = 150 TOTAL EQUIVALENT FEET OF STRAIGHT PIPE 4.3 PSI 25 PSI 29.3 PSI 30.7 PSI 30.7 PSI PRESSURE AVAILABLE X 100/150 = 20.5 AVAILABLE PER 100 FT OF PIPING. SYSTEM PIPE SIZING IS BASED UPON A MAXIMUM PRESSURE DROP OF 8.0 PSI PER 100' OF PIPING, 8.0 FPS MAXIMUM VELOCITY FOR ALL COLD WATER PIPING AND 5.0 FPS MAXIMUM VELOCITY FOR ALL HOT WATER PIPING. FOLLOW PIPE SIZING SCHEDULE BELOW ON SMALLER PIPING. PIPE SIZE SCHEDULE TYPE L COPPER SIZE G.P.M. F.T. F.V. 1/2" 5 6 3/4" 12 16 1" 19 28 - 1 1/4" 29 51 12 1 1/2" 40 86 28 2" 72 236 116 2 1/2" 3" C+J WASHINGTON STATE LICENSE PENDING QROF ESS /04/4 P:Z w 06 P. 6/30/09 1 1 /%h pV Technical Solutions & Services, Inc. 4000 Valley Blvd., Suite 103 Walnut, CA 91789 t: (909) 598-6067 f: (909) 598 -6089 SEPARAT REQUIR tab ect IJ Plu CI Gas City of 1 BULDING PERMIT D FOR: ap Ica! L cal B ing p iping ' ukwila DIVISION REVI WED FOR- E C. , OMPLIANCE PROVED J L 11 zoos B�1 �► IN Of Tukwila DIl1I;I 633 SOUTHCENTER, SEATTLE, WA 98188 N z w 0 M 0 0 cu u) w Col W no 0 0 n 0 CO 0 oe 0 W a 0 0 w ti 0 0 n M W 1- z 0 TENANT: KEVIN LEE a co cu 0 0 u) 0 FILE : `. PY Permit , Mar review approval is subject to mom and om.%sions. Approval of construction documents does not a1Ehhoriza the vi Nation of any adopted code or .1-4. _ . Receipt of approved Field C and ,. ,,,. is : 4 6 , dpi: Ciy Data: 7/ / /0 City of Tukwila BUILDING DIVISION 1 4545 VALLEY VIEW AV, SUITE B, SANTA FE SPRINGS, CA 90670 TUTTI FRUTTI FROZEN YOGURT RETAI L PLUMBING LEGEND, NOTES, R ECEIVED SCHEDULES AND CITY OF TUKWILA J'JL 08100B FLOOR PLAN PERMIT CENTER SCALE: AS NOTED DATE: 05/20/08 ��Vig10� N01 _ L Fk05- I �3 cO a (11 O J ti 0 G33 SOUTI SEATTLE, WA PLAN CHECK CORRECTIONS PLAN CHECK CORRECTIONS ISSUE FOR PLAN CHECK FOR PLAN CHECK USER: CHECH00110 DRAINAGE FIXTURE UNITS CONNECTED REQUIRED RATE OF FLOW PER MINUTE, GALLONS GREASE RETENTION CAPACITY, POUNDS 8 20 40 10 25 50 13 35 70 20 50 100 alma 180 /02 /S 180/90/9 180/60/9 180 /LO /L REVISIONS /SUBMISSIONS ISSUE FOR PLAN CHECK PLAN CHECK CORRECTIONS PLAN CHECK CORRECTIONS ISSUE FOR PLAN CHECK 'ON 1 r ' ' N Cr) GREASE TRAP SIZING CALCULATION GREASE TRAP SIZING PER 2006 UPC G re a se T ra p Fixture 3 Com p. Sink Food Prep Sink Am ount 1 1 D F U (E ach) 6 3 Total DFU 6 3 TOTAL DFU = 9, CORRESPONDING SIZE REQUIRED: 25 GPM WITH GREASE CAPACTIY OF 50 LBS. GREASE TRAP SIZING CALCULATION SCALE: NONE ELECTRIC WATER HEATER DETAIL SCALE: NONE SCALE : NONE SHUT OFF VALVE 3 /4"HOT WATER TO FIXTURE COMBINATION TEMPERATURE & PRESSURE REUEF VALVE 3/4 "(OR SAME SIZE AS REIJEF VALVE OUTLET)COPPER DRAIN T &P DISCHARGE TO MOP SINK 1/8 "THICK STEEL PLATE WELD TO ANGLE FRAME 3 "x3 "x 1/4 "FRAME WELD ALL SEAMS NOTE PLATFORM, SUSPENSION AND DRAIN PAN BY G.C. THERMAL EXPANSION TANK OR APPROVED EQUALS GALLONS CW SUPPLY SHUT --OFF VALVE „.... ....—GATE VALVE (TYP) UNION— (TYP) DRAIN TO MOP SINK I Lo5 SINKS P -TRAP VENT (AIR INTAKE) J FLOW CONTROL FLOW GREASE TRAP INSTALLATION DETAIL 3 /8 "oxr AT 1/3 OF TOP AND BOTTOM LONG LEG BOLTS (TYP 4) SECURE HEATER TO WALL 16 GA. GALV. STEEL DRAIN PAN — SOLDER ALL SEAMS 1 3- COMPARTMENT GREASE TRAP c+J QRoF 0).../4,44, 4 �� t. JDL(E S S/ <(, v, No. G M 31009 r rn n L a n • EXP. 6/30/09 N .. 4000 Valley Blvd., Suite 103 Walnut, CA 91789 t: (909) 598 -6067 f: (909) 598 -6089 VENT Technical Solutions & Services, Inc. 633 SOUTHCENTER, SEATTLE, WA 98188 TENANT: KEVIN LEE 1 4545 VALLEY VIEW AV, SUITED, SANTA FE SPRINGS, CA 90670 TUTTI FRUTTI FROZEN YOGURT RETAIL PLUMBING DETAILS RECEIVED CITY OF TUKWILp` JUL 0 8 2008 PERMIT CENTER SCALE: AS NOTED DATE: 05/20/08 G33 SOUTNCENTER, SEATTLE, WA USER: CJTECI-100110