Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG08-169 - WESTFIELD SOUTHCENTER MALL - CINNABON
CINNABON 2800 SOUTHCENTER MALL PG08-169 Parcel No.: 6364200010 Address: Suite No: Citylif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 2800 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -169 07/17/2008 01/13/2009 Tenant: Name: Address: Owner: Name: Address: CINNABON 2800 SOUTHCENTER MALL, K -2628 , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA Contact Person: Name: GREG KOMAN Address: 9 103 AV NE , BELLEVUE WA Contractor: Name: WILLIAMS MECHANICAL INC Address: 3903 SMITH AV , EVERETT WA Contractor License No: WILLIMI088PA Phone: Phone: 425 455 -4200 Phone: 425 303 -0828 Expiration Date: 10/01/2009 DESCRIPTION OF WORK: PLUMBING FOR NEW FOOD USE KIOSK including installation of a grease trap. Value of Plumbing /Gas Piping: Fees Collected: $5,000.00 $196.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and/or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 1 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 1 Medical gas piping (6 +) inlets /outlets 1 2 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -169 Printed: 07 -17 -2008 City otTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -169 Issue Date: 07/17/2008 Permit Expires On: 01/13/2009 Permit Center Authorized Signature Date: Oil a 4 a I hereby certify that I have read an ex. ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • wi , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: ('�r� h Date: -7' /7 —G Er- Print Name: $ li.r J -t5 - „i 5 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -169 Printed: 07 -17 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2800 SOUTHCENTER MALL TUKW CINNABON Permit Number: Status: Applied Date: Issue Date: PG08 -169 ISSUED 06/05/2008 07/17/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 14: Tenant shall follow the Grease Waste Maintenance Program dated January 30, 2008, copy attached. * *continued on next page ** doc: Cond -10/06 PG08 -169 Printed: 07 -17 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: $)CC /7 13,06A.- S Date: 7—/7--e-' ordinances governing or local laws regulating doc: Cond -10/06 PG08 -169 Printed: 07 -17 -2008 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.vva.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE. LOCATI Site Address: Tenant Name: ����� / King Co Assessor's Tax No.: 6 34 421 -CA01 5 k- 2(c,z c tti7t�� -nor /%lc, // C�- fry h -6e-. Suite Number: Floor: New Tenant: —Yes ❑..No Property Owners Name: 1i) 451-; - e ee lr. Mailing Address: /7L/ W/t /5/')/rre_ R/.id V #1)741 �� / 1A- 5 5 City State Zip fir^ t.J''� ,is;S� <a %; "•ifrYl;; iy'yMf}3s'Tii`i::^;5f:i.;9' CONTACT PERSON - Who. do we contact when your" permit is ready to be issue Name: 6 /`Liifi 6 V a Mailing Address: / /�''_%�3"k Ave NE E -Mail Address: �/CO/>7 e„ a_ ins,- Day Telephone: la $- 45 '5- -- 7- BP//em C� City State Zip Fax Number: 4/1aS - Se$-S - Cf/ % GENERAL. CONTRACTOR IN ORiMATION`r e °•'r1t ?r.,,.k s. :r >.ukN -. ,•>ur,�.r,,,;�jrt ,,. ...4•a .d . r. k.r wjr.7:re " -.. 'g�:yRr -�C�rc ''• %4.� (ContractorInformation for ir[echanrcal.(pg 4j for:Plumbing and Gas - Piping tpg Company Name: P Mailing Address: -- Zip Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State ARCHITECT OF RECORD -- A11 lens must'be vet. stamped by Architect. of Record` Company Name: Z3 %- ►- Mailing Address: / % 71) -L/TT 2d/ a, Mt l Rc. %Vd GA- L e5 City State Zip Day Telephone: 72 ^ ?9' 44l- Fax Number: `776 - 3cYf- -2623 Contact Person: t\Q� C-. e: k40- re-;51174Y) E -Mail Address: G Q 1674e r.:x°5. c .•'m ENGINEER OF RECORD All plans must b'e wet stamped byngtneer;of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:NpplicationslFotms- Applications On Line'3 -2006 - Penoit Applievion.th+c Revised: 9.2006 bh Page 1 of 6 BUILDING,PERMIT INFORMATION `-, 206- .431 -3670 .' Valuation of Project (contractor's bid price): $ 55-- Od d Existing Building Valuation: $ Scope of Work (please provide detailed information): IN/ e /610.k — J °e S e Will there be new rack storage ?' E Yes ' No If yes, a separate permit and p submittal will be required. ovide All Building Areas in Square-Foottage. .., . -,,, ..., .. p , Existing • t ' erior Remodel •. • s Addition to - � Fxlsting ,• '� .. . as Structur , . �,.t .. ... New , t, Type of r r d y� ,1 ;Constructionper -, -{i FIS. > '} Y J4 ,� ..b �18C , ;a.. .�' Type of '.x b cgs O1ccupanc}iper,. "eft• "n, t, •>� }�t. • . Y.:. •:IBC . : r:t I< Floor 1 '"„ Floor.•;;; = . :,ysk�s:. ':4"... :Fy:t >~i', +gym; !,L -6 / 2_ . .'4•:.r .. T9,F.17�oor -.1`; `r, : :`oot .. -, , .-'Floois: c'ifi,rh if _thrlt'3`.": ' "ri ; -fig is ;fra-' :' Basement s'..` §r &'ir~ r't` 1 i T,� 'a:F,: b, 11 t. jc .,. a a • ;Accessiii0truc '? z'••y,, }' - Aettacheed • Garage ; F µr'�Y ':Detached Garage:; "u : <Attached.Carport. ,:'rev ,° ,:a,o • Detached Carport ..:krf x, ; , b �Ir r� Covered Deck`'i: ".' Uncgveied Deck'.' PLANNING DIVISIO: Single family building tprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory d fling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Plumber of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No if "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x I 1 "paper including quantities and ,Material Safety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. p:'ApplicaeonstFomts- Applications On Linek3.2006 - Permit Application -doe Revised: 9 -ZbOR bb Page 2 of 6 PLUMBING AND GAS PIPING PERMIT INFORMATION'- 206 - 431_367 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ J• 606 Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): P/411.7-7 �J ! k, 's use Building Use (per Int'l Building Code): T.-- -6 Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: FixtureType:: .`..::.:.; ...:..QtY .'FixtureType : :.::: : ..:..: ;Qt,:, ..FistureType:':;..,.'_. <. Qty; .Fixture Type:: °,:;; ,' : :.! >;;;.:','• Qty Bathtub or combination bath/shower _ Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste % Clothes washer, domestic Floor drain / Sinks a Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent / Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment / Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas ( Mpplications'FotmrApplications On L n '3 -?OO6 - Permit Application.do. Revised: 9-2006 bb Page 5 of 6 PERMIT APPLICATION NOTES - Applicable to all permits`><n:this application- Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 OR THORIZED ENT: Signature: Print Name: »?oclitra /#9- Pf 2) f Geol2LD Mailing Address: Date: 6/5/b Day Telephone: F412_—<-4 -7/ gvoi 63.3 e ..,4, , / IJ4, 31 Ci State Zip Date Application Accepted: Date Application Expires: I7-losivrb Staff Initials: Q'Applicanons '.Pamir - Applications On Line'3 -20116 • Permit Applicadon.doc Revised: 9.2006 bh it I Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -169 Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 06/05/2008 Applicant: CINNABON Issue Date: Receipt No.: R08 -02624 Initials: User ID: JEM 1165 Payment Amount: $164.00 Payment Date: 07/17/2008 10:51 AM Balance: $0.00 Payee: SCOTT BROOKS TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 164.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.0 164.00 Total: $164.00 4963 07/17 9710 TOTAL 164.00 doc: Receiot -06 Printed: 07 -17 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -01967 Initials: JEM User ID: 1165 Payee: M.E.S. MANAGEMENT CO. Payment Date: 06/05/2008 Total Payment: 648.00 SET ID: 5000001044 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08 -315 566.80 EL08 -693 49.20 GO 8„1 9 32.00 TOTAL: 648.00 TRANSACTION LIST: Type Method Description Amount Payment Check 3077 648.00 TOTAL: 648.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 49.20 000/345.830 598.80 TOTAL: 648.00 3342 06/06 9711 TOTAL 648.00 r.... oonoc■o no INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION le- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Probe t: C� (IQlvA Type of Inspection: 11v1A(— Ply-,-•1-) Address: 2P)xomA-k\ Date Called: Special Instructions: Date Wanted: -7- 23-49 p.m. Requester: Phone No: 2 //-- e _ ( _ Approved per applicable codes. Corrections required prior to approval. COMMENTS: P.,/ .,.e-..11C j> /h /r / 1 r1,i - C: f - at 4/.1/#d'- 5 /ye„ A. 7. l 1 d, : )err 5ig1 1c-F/d- 94 1 2-.2Y-4 Inspector: l 'Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION M- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 p16- os- Project: c...,...60,-, Type of Inspection: RF M �itv Address: 2$ o9 Date Called: Special Instructions: Date Wanted: % ' �, � p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: rA �uv ok (Ow-ree:I.t. ( 5-6171y 0 Date: $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calllo schedule reinspection. Receipt No.: Date: 2 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION let 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Cs1MKG� °�'1 Type of Inspection: (/I.0 5re�a(/l /got Address: 2 f�00 f 6 k- Date Called: Special Instructions: Date Wanted: ,2ZeOS a.m. Requester: c % %,vt Phone No: 5°aq g7e 22.P1 © Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: till (work. ®/c Inspector: Date: 722,'Y EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. `Receipt No.: 'Date: June 20, 2008 Ms. Joanna Spencer Public Works Department City of Tukwila 6300 Southcenter Blvd. Tukwila, WA 98188 RE: Southcenter Mall Expansion Tenants using Grease Interceptors/Tenants using "under the sink" Grease Traps Dear Joanna: estfield Westfield, LLC 633 Southcenter Mall Trailer #3 Tukwila. WA 98188 Telephone (206) 802 -6071 Facsimile (206) 246 -7043 At your request, following is a list of Tenants who will be using Landlord supplied grease interceptors as well as a list of Tenants who will be using Tenant supplied "under the sink" grease traps when the Southcenter Mall expansion opens on July 25, 2008. The following Tenants have their own independent grease interceptor provided by Landlord: Blue C Sushi — 468 Southcenter Mall Duke's Chowderhouse = 757 Southcenter Mall Joey's Grill & Lounge = 758 Southcenter Mall BJ's Restaurant/Brewhouse — 1159 Southcenter Mall Racha Thai = 1150 Southcenter Mall The following Tenants will share a common grease interceptor provided by Landlord: Emerald City Smoothie — 728 Southcenter Mall Starbucks Coffee — 1047 Southcenter Mall Auntie Anne's - 1120 Southcenter Mall Shared East Side Dining Terrace Tenants: Johnny Rockets — 2600 Southcenter Mall, FC -1 Sharky's — 2600 Southcenter Mall, FC -2 Sarku — 2600 Southcenter mall, FC -3 Sbarro — 2600 Southcenter Mall, FC-4 Current Vacant Food Court Tenant —2600 Southcenter Mall, FC -5 Subway — 2600 Southcenter Mall, FC -6 Daphne's Greek Cafe — 2600 Southcenter Mall, FC -7 Sushi Itto — 2600 Southcenter Mall, FC -l3 Kudo Beans — 2600 Southcenter Mall, FC -14 Thai Go — 2600 Southcenter Mall, FC -15 RECEIVED CITY OF TUKWILA JUL 012008 PERMIT CENTER CORRECTION PW I(1 6/25/2008 Page 2 Shared West Side Dining Terrace Tenants: Current Vacant Food Court Tenant — 2600 Southcenter Mall, FC -8 Charley's Grilled Subs — 2600 Southcenter Mall, FC -9 Panda Express — 2600 Southcenter Mall, FC -10 Chicken Now — 2600 Southcenter Mall, FC -11 Ivar's — 2600 Southcenter Mall, FC -12 Red Mango — 2600 Southcenter Mall, FC -16 Borders Cafe — 2437 Southcenter Mall • The following Tenants will not have use of a Landlord supplied grease interceptor as they are not close enough to one of Landlord's grease interceptors or are a very low producer of grease waste. Westfield has been approved by Tukwila Public Works Department to allow these Tenants to use a Tenant supplied "under the sink" grease trap so long as they follow the Grease Waste Maintenance Program dated January 30, 2008 (copy attached). This program has been established between Baker Commodities and Westfield, with the prescribed grease trap cleanout schedule to be designated by Baker based on the Tenant's needs. Michael Cusick, Utilities Engineer for Public Works Department, has requested to be present at one of the appointed cleanout days so that he can be satisfied that Tenants and Baker are complying with the Grease Waste Maintenance Program and also to see how Baker Commodities works with the remote cleaning units. Auntie Anne's = 546 Southcenter Mall Godiva Chocolatier — 555 Southcenter Mall Teavana — 856 Southcenter Mall Pretzel Time Kiosk — 2800 Southcenter Mall - #K -0303 (currently existing) Tutti Frutti Kiosk — 2800 Southcenter Mall #K -0305 Bobalicious Kiosk — 2800 Southcenter Mall #K -0310 Cinnabon Kiosk — 2800 Southcenter Mall #K -2628 Ben & Jerry's Kiosk — 2800 Southcenter Mall #K -2688 Please contact me if you have any questions regarding Tenants utilizing Landlord supplied or Tenant supplied grease interceptors. Sincerely, Marcia Peddicord Tenant Coordination Westfield Southcenter Cc: Jim Morrow Michael P. Cusick Dear Andrew, Baker Commodities Inc. would like to thank you for consideration or our company. Our goal is to provide the best possible service for your grease trap needs. As per our conversation we can schedule and maintain all of your new locations needs. Services for the grease traps will include: • Removal of All Waste from the grease traps. • All waste is pumped into a holding tank on our trucks and then brought back to our plant for onsite recycling. • If trap' is too far from the truck we use a portable pumping system. • This system is then wheeled back to the truck and pumped into our holding tank: • The grease traps will be backfilled after cleaning to insure proper draining. • Baker Commodities Inc. does not use, sell, handle, or recommend the use of chemicals and /or "bio- degradable" products. • Please advise the restaurant owners that you do not want these types of product used. • An inspection and service report will be left at each location. • Customers will be required to provide a regular cleaning schedule. • All customers will be contacted prior to each service. • Westfield will be included with a copy of the services by e-mail or fax: If you have any question or concerns please do not hesitate to' give us 'a call @ 206 - 243 -7387 Thanks, Jim Hodge Baker Commodities Inc. Seattle Division BAKER COMMODITIES INC._Qaa1U,, axd_Ffide...tuoaadaide P.O. Box 58368, Seattle, WA 98138 (206) 243 -7387 FAX (206) 243 -3412 Wetfiekf Southcenter �GRsEASE„,TRAPt�AINTEI�iAN 2Y 30; ominas ' PURPOSE: The intent of this program is to provide maintenance guidelines for any new food -use retailer utilizing a grease trap in place of a grease interceptor so as to minimize health, safety and environmental concerns. POLICY: All new retailers utilizing a grease trap in place of a grease interceptor will be required to contract the services with a Landlord- required grease waste contractor. Each store will have their grease trap maintained (as per the details below) a minimum of every two months. Proof of service should be kept on -site as well as copied to the mall management office (directly from the contractor). There shall also be placed on -site (and available at Landlord's request), a grease trap maintenance log which the contractor will complete upon each bi- monthly service. PROCEDURE: Below is the procedure for grease trap cleaning and recycling to be provided by a required vendor (see sample proposal attached): 1. Removal of all waste from grease traps: 2. Contractor will utilize a portable pumping system when necessary. 3. The grease traps will be backflled after cleaning to insure proper draining. 4. Contractor will not use any biodegradable or chemicals that might temporarily break up grease but lead to re- coagulating later on. 5. An inspection and service report Will be left at each location. 6. Customers will be required to provide a regular cleaning schedule: 7. All customers will be contacted prior to each service: 8. Westfield will be included with a copy of the services by email or fax. COMPLIANCE Fines will be levied for non - compliance. If our Maintenance Engineers or contracted vendor is denied access to the space during the scheduled removal or during an emergency removal, a $100 fine for each instance will be levied for each occurrence. Retailer Name: Grease Trap Log Space Number: Contractor Signature s w Repairs /Remarks _ 1 I, Amount of Grease Removed 'Date 2 DRAWING NUMBER S8000 SERIES SMITH® JAY R. SMITH MFG. CO. CUSTOMER DRIVEN DIVISION OF SMITH INDUSTRIES, INC. POST OFFICE BOX 3237 MONTGOMERY, ALABAMA 38109-0237 (USA) TEL: 334- 277 -8520 FAX 334- 272 -7396 www.jrsmith.com 0 0 0 0 0 0 0 w uwi Q o_ OitSiC-e Vl ap O LOCATION FILE COPY GREASE I NTE RCEPitt FUNCTION: Used in kitchens, restaurants, institutions, and all typerilf'fo6d'Or6ae g aaastwhere was e water contafns' i # a '1 C grease, fats and oil. Rate of flow into interceptor is controlled by a fl?w control fitting, thus'enabfing the interceptor to collecT over' t.. :. . 90% of the grease which flows into it. "Uni -lock" cover design permits fast cover removal for periodic cleaning. Interceptor may be set on floor, semi - recessed in floor or fully recessed with cover flush with finished floor. Fig. 8100 Series are extra low designs adaptable for use with dishwashers or low roughing sinks. Lock and Lift Ring Non -Skid Cover \ Cleanout- A Outlet APPROVED BY: 2 ) CHECKED BY: 0 a3 a' z 0 0 V/ w w O O O 00 U.1 IY Lu CE co LL Z DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE Inlet SIDE VIEW FIG. 8010 SHOWN A Neoprene Gasket Air Relief Static Water Line Removable Baffles D A NOTE: When tile top is specified add 1 "(25). When Terrazzo top is specified add 1 1/4"(32) M L K J REV. *Available with larger inlet and outlet when specified. REGULARLY FURNISHED: Steel Interceptor with Gray Duco Coating Inside and Outside and Flow Control Fitting. 2 -3 -05 7 -09 -99 12 -10 -98 6 -20 -97 DATE Revised Variations Revised Text Added Note Redraw Baffles VARIATIONS: I= A Cover Recessed for Terrazzo, Ceramic or Quary Tile -QC A Cover Recessed for Vinyl or Asphalt Tile -TC 8 Lift Out Sediment Bucket -B NO -HUB Adaptor (2) Req'd (Specify Fig. 2646Y) 1= Traffic Rated Cover -H20 DESCRIPTION RN CL JJ BS CMD BS EMB BS BY CKD. BY Figs. 8007 thru 8050 carry the Plumbing and Drainage Institute Certification Seal Certifying conformance to Grease Interceptor Standard PDI -G101. NOTE: It is the responsibility of the installer to check all parts (internal and external) to verify they are in their proper operating order and location. NOTE: Whenever an interceptor is to be installed suspended in a floor slab with a cradle or independently, proper support is essential for safety and functional integrity of the installation. Supports/support system shall be of sufficient strength and proper design for the purpose intended and meet the approval of the architect and structural engineer. Jay R. Smith Mfg. Co. is not responsible for the design or recommendation of such supports. Upon request, Jay R. Smith Mfg. Co. will provide the weight of the specific unit. Additional weight must be added to compensate for the weight of the liquid/grease when full and in the flowing mode of operation. RECEIVED CITY OF TUKWILA JUN 0 5 2008 PERMIT CENTER OPTIONAL MATERIALS: Acid Resistant Coating Inside - ARI Acid Resistant Coating Outside - ARO Acid Resistant Coating Inside and Outside - ARIO 1 1 Aluminum Cover -AC NOTE: Dimensions shown in parentheses are in millimeters. WEIGHT POUNDS VOLUME CUBIC FEET FIGURE NUMBER 8000 SERIES EXUSTIN1,-7 FIG NO. GPM FLOW RATE GREASE CAP. LBS. INLET AND OUTLET SIZE A* DIMENSIONS C.O. PLUG SIZE ROUGHING DIMENSIONS BODY HEIGHT WIDTH B C D E F G 8004 4 8 02(50) 7 3/4(195) 3 1/4(83) 16 3/4(425) 11(280) 9(230) 2(51) mi 8007 7 14 02(50) 8 1/2(215) 3 1/2(89) 19(485) 12(305) 10(255) 2(51) 8010 10 20 02(50) 9 1/2(240) 3 3/4(95) 21 1/4(540) 13 1/4(335) 11 1/2(290) 2(51) 8015 15 30 02(50) 12(305) 3 1/2(89) 25(635) 15 1/2(395) 13 1/2(345) 2(51) 8020 20 40 03(75) 13(330) 4(100) 28 1/2(725) 17(430) 153/4(400) 2(51) 8025 25 50 03(75) 15 1/4(390) 4 1/2(115) 30(760) 19 3/4(500) 16 3/4(425) 2(51) In m 8035 35 70 03(75) 16(405) 5(125) 32 1/2(825) 21(535) 18 1/4(465) 2(51) 2(51) 8050 50 100 03(75) 17 1/2(445) 63/4(170) 35 1/2(900) 24 1/4(615) 20 3/4(525) Mil LOW TYPE 8120 20 40 03(75) 7(180) 3 1/2(89) 38 1/2(980) 10 1/2(265) 21 3/4(550) 2(51) 8135 35 70 03(75) 7(180) 4 3/4(120) 49 1/2(1257) 11 3/4(300) 27 3/4(705) 2(51) 2(51) 8150 50 100 03(75) 10(255) 6(150) 49 1/2(1257) 16(405) 273/4(705) M L K J REV. *Available with larger inlet and outlet when specified. REGULARLY FURNISHED: Steel Interceptor with Gray Duco Coating Inside and Outside and Flow Control Fitting. 2 -3 -05 7 -09 -99 12 -10 -98 6 -20 -97 DATE Revised Variations Revised Text Added Note Redraw Baffles VARIATIONS: I= A Cover Recessed for Terrazzo, Ceramic or Quary Tile -QC A Cover Recessed for Vinyl or Asphalt Tile -TC 8 Lift Out Sediment Bucket -B NO -HUB Adaptor (2) Req'd (Specify Fig. 2646Y) 1= Traffic Rated Cover -H20 DESCRIPTION RN CL JJ BS CMD BS EMB BS BY CKD. BY Figs. 8007 thru 8050 carry the Plumbing and Drainage Institute Certification Seal Certifying conformance to Grease Interceptor Standard PDI -G101. NOTE: It is the responsibility of the installer to check all parts (internal and external) to verify they are in their proper operating order and location. NOTE: Whenever an interceptor is to be installed suspended in a floor slab with a cradle or independently, proper support is essential for safety and functional integrity of the installation. Supports/support system shall be of sufficient strength and proper design for the purpose intended and meet the approval of the architect and structural engineer. Jay R. Smith Mfg. Co. is not responsible for the design or recommendation of such supports. Upon request, Jay R. Smith Mfg. Co. will provide the weight of the specific unit. Additional weight must be added to compensate for the weight of the liquid/grease when full and in the flowing mode of operation. RECEIVED CITY OF TUKWILA JUN 0 5 2008 PERMIT CENTER OPTIONAL MATERIALS: Acid Resistant Coating Inside - ARI Acid Resistant Coating Outside - ARO Acid Resistant Coating Inside and Outside - ARIO 1 1 Aluminum Cover -AC NOTE: Dimensions shown in parentheses are in millimeters. WEIGHT POUNDS VOLUME CUBIC FEET FIGURE NUMBER 8000 SERIES EXUSTIN1,-7 Spebification Plumbing and Drainage Products including engineered drainage systems, va... Page 1 of 1 SMITH ;I'''' • .1 -' .; :a SMITH MFG. CCU. ....,., 54 tl. t1 (vt.I... tNH> Ptt,vpi M(s PW44UG+% FAMILY OF PRODUCTS: JRSPRODUCTS.COM CONTRACTOR - FRIENDLY PRODUCTS HOME ABOUT US PRODUCTS INTERNATIONAL /CANADA MARKETING PORTA 8000GT GREASE INTERCEPTORS 8000/8100 8200 8000GTX GREASE INTERCEPTORS WITH SEMI- AUTOMATIC DRAW -OFF FUNCTION: Used in all areas where grease, oil and fats must be intercepted and collected. Unique semi- automatic draw -off design permits removal of accumulated grease without cover removal. When specific directions are followed, accumulated grease in liquid form is discharged through the semi - automatic draw -off piping for convenient disposal. This design eliminates the messy cleaning job which must be done in ordinary types of interceptors. Regularly Furnished: Variations: Steel Interceptor with Gray Duco Coating Inside and NO -HUB Adaptor (2) Req'd Outside with Steel Cone, Draw -off Piping and Valve, (Specify Fig. 2646Y) Line Shut -off Valve and Flow Control Fitting. Grease Aocumulalinr,j G r;Cleancuti Lin€ Shut -d1 Va Fig. 8035GT Shown F Outlet Optional Materials: Acid Resistant Coating Ins Acid Resistant Coating Ou Acid Resistant Coating Inside and Outside -ARII; PCN/ FIG. NO. GPM FLOW RATE GREAS CAP LBS. INLET E AND OUTLET SIZE A' C2 CQ 03 63 03 16 5 32 1/2 03 1712 63'4 35 1.2 04 211/2151,2 8StQ7T T 10 15 20 26 35 801 OGT 8015GT 8020GT 8025GT 9035(7 GT 14 20 3] 40 50 70 00 11075GT 755 f?s12C T 20 :1 T 8150 GT DIMENSIONS ROUGHING BODY DIMENSIONS }IEIGHT W D C D E 8Ir2 31/2 19 12 9 12 3 3/4 21 144 13 1/4 12 31.2 25 1512 13 4 29 12 17 151/4 41//2 30 103`4 21 15 16 19 24 1/4 20 5o 37 30 LO 40 7 Ik ico 03 10 `1 TYPE 3 1: 434 6 1.2 101,2 2 4 49 12 11 44 16 27 'AA)iL4ble with tritsyar Lila And owe . $i ti 6lrAcitiael ordering example: 8007T02GT http://www.jrsmith.com/ 6/4/2008 LIGHT COMMERCIAL GT2700 Grease Interceptor TAG Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice GT2700 -4 through GT2700 -50 1 GT2700 -75 & GT2700 -100 Model Number NB Inlet /Outlet No -Hub Flow Rate G.P.M. [L] Capacity Grease Lbs. [kg] Dimension in Inches C D/E F G GT2700 -4 2 [51] 4 [15] 8 [4] 10 [254] 7 1/4 [184] 15 7/8 [403] 9 7/8 [251] _ GT2700 -7 2 [51] 7 [26] 14 [6] 11 1/8 [283] 8 1/8 [206] 17 1/4 [438] 11 7/8 [302] _ GT2700 -10 2 [51] 10 [38] 20 [9] 11 3/4 [298] 8 1/4 [210] 19 1/4 [489] 14 [356] _ GT2700 -15 2 [51] 15 [57] 30 [14] 13 3/8 [340] 9 3/8 [238] 21 1/4 [540] 16 3/4 [425] GT2700 -20 3 [76] 20 [76] 40 [18] 15 [381] 11 3/4 [298] 24 1/8 [613] 17 1/4 [438] _ GT2700 -25 3 [76] 25 [94] 50 [23] 17 [432] 12 1/2 [318] 26 1/8 [644] 19 7/8 [505] GT2700 -35 4 [102] 35 [132] 70 [32] 18 3/4 [476] 14 1/4 [362] 28 [711] 22 1/2 [572] GT2700 -50 4 [102] 50 [189] 100 [45] 21 1/2 [546] 16 [406] 29 7/8 [759] 24 1/2 [622] GT2700 -75 4 [102] 75 [283] 150 [68] 22 3/4 [587] 18 1/2 [470] 36 [914] 28 5/8 [727] GT2700 -100 4 [102] 100 [379] 200 [91] 27 [685] 23 [584] 42 3/4 [1086] 33 5/8 [854] GT2700 Grease Interceptor Recommended for removing and retaining grease from wastewater in kitchen and restaurant areas where food is prepared. Grease trap is corrosion - resistant coated fabricated steel with no -hub connections, flow diffusing baffle, integral trap, and vented inlet flow control device. OPTIONS - JP2700 6 [152] Extension Sizes 4 - 50 Sizes 20 G.P.M. - 50 G.P.M. ZURN LIGHT COMMERCIAL PLUMBING PRODUCTS • 2640 South Work Street • Falconer, NY 14733 Phone: 1- 800/9065060 • Fax: 716/665-3126 • World Wide Web: www.zurn.com - � yEc3TEJ (;tT Rev. A Date: 1/5/05 C.N. No. 84460 Dwg. No. 63802 Product No. GT2700 NORDSTROM mdcyS O 0 0 - 0 0 0 0_ o 00 0 • 0 0 __ 0 The document is diagrammatic and is intended only to shod the demised premises of the project (holched area.) It does not purport to shod exact dimensions nor the find location of any mechanical, electrical, structural or architectural element. Further, the landlord reserves the right to add, eliminate or modify any such element, as may be required from time to time, Tenant space dimensions, unless otherwise noted are to the centerlines of tenant partitions and column grids, face of exterior walls and to the outside face of service area partitions adjacent to the tenant space (viz. corridors, closets, and stairs.) SOUTHCENTER 0'. - 10' 20' Level 1 11/02/07 1560 LADY FOOTLOCKER 2,162 S.F. EXHIBIT A2 Dear Andrew, Baker Commodities Inc: would like to thank you for consideration or our company. Our goal is to provide the best possible service for your grease trap needs. As per our conversation we can schedule and maintain all of your new locations needs. Services for the grease traps will include: • Removal of All Waste from the grease traps. • All waste is pumped into a holding tank on our trucks and then brought back to our plant for onsite recycling. • if trap• is too far from the truck we use a portable pumping system. • This system is then wheeled back to the truck and pumped into our holding tank: • The grease traps will be backfilled after cleaning to insure proper draining. • Baker Commodities Inc. does not use, sell; handle, or recommend the use of chemicals and /or "bio- degradable" products: • Please advise the restaurant owners that you do not want these types of product used. • An inspection and service report will be left at each location. • Customers will be required to provide a regular cleaning schedule. • All customers will be contacted prior to each service. • Westfield will be included with a copy of the services by e-mail or fax. If you have any question or concerns please do not hesitate to give us 'a call @ 206- 243 -7387 Thanks, Jim Hodge Baker Commodities Inc. Seattle Division BAKER CO MODITIES_INC._Qaa j_ axd_PWC.,Wa_*QdmiJ - - -- P.O. - Box 58368,- Seattle, WA 98138 (206) 243 -7387 FAX (206) 243 -3412 CITY RECEIVED UKWILA JUN 0 5 2008 PERMIT CENTER WA 14 'Westfield Southcenter EGT, 2ME�AS P' IV AI,,NTr�,E, N Elgrafek ARLIVOI PURPOSE: The intent of this program is to provide maintenance guidelines for any new food -use retailer utilizing a grease trap in place of a grease interceptor so as to minimize health, safety and environmental concerns: POLICY: All new retailers utilizing a grease trap in place of a grease interceptor will be required to contract the services with a Landlord- required grease waste contractor. Each store will have their grease trap maintained (as per the details below) a minimum of every two months. Proof of service should be kept on -site as well as copied to the mall management office (directly from the contractor). There shall also be placed on -site (and available at Landlord's request), a grease trap maintenance log which the contractor will complete upon each bi- monthly service: PROCEDURE: Below is the procedure for grease trap cleaning and recycling to be provided by a required vendor (see sample proposal attached): 1. Removal of all waste from grease traps. 2. Contractor will utilize a portable pumping system when necessary. 3. The grease traps will be backfilled after cleaning to insure proper draining. 4. Contractor will not use any biodegradable or chemicals that might temporarily break up grease but lead to re- coagulating later on. 5. An inspection and service report will be left at each location. 6. Customers will be required to provide a regular cleaning schedule. T All customers will be contacted prior to each service. 8. Westfield will be '.included with a copy of the services by email or fax. COMPLIANCE Fines will be levied for non - compliance. If our Maintenance Engineers or contracted vendor is denied access to the space during the scheduled removal or during an emergency removal, a $100 fine for each instance will be levied for each occurrence. Grease Trap Log Contractor Signature 1 Repairs /Remarks _ 1 Amount of Grease Removed, Date • • June 24, 2008 • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Greg Koman 9 103rd Avenue NE Bellevue, WA 98004 RE: CORRECTION LETTER #1 Plumbing /Gas Piping Application Number PG08 -169 Cinnabon — 2800 Southcenter Mall, #K -2628 Dear Mr. Koman, This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Public Works Department has no comment. Building Department: Allen Johannessen at 206 - 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Brenda Holt Permit Coordinator encl xc: File No. PG08 -169 P:\Pennit Center \Correction Letters\2008\PG08 -169 Correction Ltr #1.DOC wer 6300 Southcenter Boulevard. Suite #100 • Tukwila. Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 i Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: June 16, 2008 Project Name: Cinnabon Permit #: PG08 -169 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Show provisions for trap primers for the floor drains and floor sinks. 2. Plan shows a separate grease interceptor containment system for this tenant. All grease waste lines shall connect to the landlord grease waste line. However there is a designated few tenants that are allowed to provide a grease waste disposal method by maintenance program similar to what has been provided for this permit due to specific location. Please confirm with the landlord and provide documentation that the proposed maintenance program with the grease waste system for this space shall be allowed. Or show grease waste connecting to the landlord grease waste system. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. HERMIT COORD COPY s PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -169 PROJECT NAME: CINNABON DATE: 07 -01 -08 SITE ADDRESS: 2800 SOUTHCENTER MALL, K -2628 Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: c14 Bu `l i ins+ division Public Works Fire Prevention n Planning Division Structural Permit Coordinator DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 07-03 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07-31-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY 0 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -169 DATE: 06 -05 -08 PROJECT NAME: CINNABON SITE ADDRESS: 2800 SOUTHCENTER MALL, K -2628 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: 4 g Division (p -a6 Fire Prevention (}Pu bl Wo k(As' rot 4) �) Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE: 06-10 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07-08 -08 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: '' Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax 206 - 431 -3665 Web site http://www.atulcwila.wa. US Steve Lancaster, Director rmRecei OF 7'cJK1vIL4 JUL 0 1 2008 PERMIT CENTER Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /j Plan Check/Permit Number: ❑ Response to Incomplete Letter # Q--- Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner e.4' Pi 1-7 4 ger-y-L_ 2_VD6 So u l-kc e - /?ia /l -Z 624 Contact Person: rnCLrG,' h fie .' -' Phone Number: '/ ? - �U 2 - 92.3 Summary of Revision: (2-e ` Project Name: Project Address: c / L / /• t fo-4 / n1LA p rove Jew, /� (1--7.,-,e 6 ``e_ T1— ,r4�7'L' 67//i s� r -mot 1-4 Z._ ce. �-t / r� b v ,,-- s l% 14- l /r" P e� r, c�.1 L� cr So 0-7/i Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 1:K. Entered in Permits Plus on RI \applications\forms- applications on Iinelrevision submittal Created: 8 -13 -2004 1/'^- Untitled Page • • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. WILLIAMS MECHANICAL INC Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company WILLIAMS MECHANICAL INC 4253030828 3903 SMITH AVE EVERETT WA 982014549 SNOHOMISH CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 601413863 ACTIVE WI LLIMI088PA CONSTRUCTION CONTRACTOR 10/1/1992 10/1/2009 WILLIPH136Q4 GENERAL UNUSED Business Owner Information Name Role Effective Date Expiration Date WILLIAMS, BRADLEY P PRESIDENT 01/01/1980 Bond Amount WILLIAMS, DEBORAH K SECRETARY 01/01/1980 2271807 ZUCCARINI, MICHAEL J AGENT 01/01/1980 01/01/1980 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 INS CO OF THE WEST 2271807 10/01/2007 Until Cancelled $12,000.00 10/01/2007 2 CBIC 634038 09/30/2001 Until Cancelled $6,000.00 09/25/2001 1 CBIC 634038 10/01/1992 09/30/2001 $4,000.00 Insurance Information Page 1 of 2 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 16 CONTINENTAL WESTERN INSURANCE CWP2643064 09/30/200709/30 /2008 $1,000,000.0009 /20/2007 15 CONTINENTAL WESTERN INS CO CWP2643064 09/30/200609/30 /2007 $1,000,000.0009 /26/2006 WEST AMERICAN INS https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= WILLIMI08 8PA 07/17/2008 0 I-- c) w cd N D } r■ n o N N Z Z 4." ;EJ Ocou7 (..1 � � c ow �> co J N RE=VISIONS: A A ri MN= 01MM MMIM=11 A PLUMBING PLANS, DETAILS, SCHEDULES, RISERS & NOTES WATER PIPING IN LOW WALL U rte ? a EXISTING 3/4" C.W. UNDER FLOOR- 0 L NO SCALE IIJI IWII11 ll 1111 Pm 1] (B60 -07) 3/4" SCALE: 1 /2" = 1 '-0 "' 1/2" CW TO INLINE FILTE 1 t- (J53 -01) (J53 -02) 4> (C21 -01) - 3 -COMP SINK C1 II II I I PLUMBING GENERAL NOTES a DOMESTIC WATER FLOOR PLAN (B60 -01) PROVIDE BACKFLOW PROTECTION AS REQUIRED (TYPICAL) (C THE EQUIPMENT ROUGH -IN ITEMS AND THEIR DIMENSIONED LOCATIONS FOR ALL CONNECTIONS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE. IN SOME INSTANCES THE OWNER OR SUPPLIER MAY MAKE SUBSTITUTIONS OR THE EQUIPMENT ITEMS MAY VARY FROM WHAT IS SHOWN. THEREFORE, THESE ITEMS AND DIMENSIONS SHALL BE VERIFIED WITH THE EQUIPMENT SUPPLIER, OWNER AND /OR EQUIPMENT ROUGH -IN DRAWINGS. THE ARCHITECT/ENGINEER SHALL BE IMMEDIATELY NOTIFIED, PRIOR TO CONSTRUCTION, OF ANY DEVIATIONS FROM WHAT IS SHOWN OR IMPLIED ON THESE DRAWINGS. FAILURE OF THE APPROPRIATE CONTRACTOR TO VERIFY ROUGH -INS OR THEIR LOCATIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION AND /OR ADDITIONAL ROUGH --INS DIRECTLY UPON THE CONTRACTOR. 2. CONTRACTOR SHALL SUPPLY TO THE ARCHITECT SIX COPIES OF SHOP DRAWINGS FOR APPROVAL 50 THE QUALITY OF INTENDED MATERIALS OR EQUIPMENT CAN BE REVIEWED BEFORE INSTALLATION. THERE WILL BE NO DRAW UNTIL SHOP DRAWINGS HAVE BEEN SUBMITTED AND REVIEWED BY ARCHITECT/ENGINEER. 3 DO NOT SCALE THIS DRAWING. REFER TO ARCHITECTURAL FLOOR PLANS FOR BUILDING DIMENSIONS. 4 THE SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTOR HAS FAMILIARIZED HIMSELF WITH THE PLANS AND BUILDING SITE. CLAIMS MADE SUBSEQUENT TO THE PROPOSAL FOR MATERIALS AND LABOR BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED, IF THEY COULD HAVE BEEN FORESEEN HAD PROPER EXAMINATION BEEN MADE. 5 VERIFY SERVICE POINTS AND METERING LOCATIONS FOR PROJECT WITH LOCAL UTILITIES AND /OR LANDLORD (DOMESTIC WATER, SANITARY SEWER, GAS, ETC.) 6 THE CONTRACTOR SHALL COOPERATE FULLY AMONG THE TRADES. 7 ALL ROOF PENETRATIONS FOR ROOF DRAINS AND PLUMBING /GAS/ REFRIGERANT PIPING SHALL BE MADE IN ACCORDANCE WITH ROOF SYSTEM MANUFACTURER'S GUIDELINES. COORDINATE WITH ARCHITECTURAL DETAILS AND /OR LANDLORD FOR ROOF SYSTEM USED. 8 PLUMBING CONTRACTOR SHALL VERIFY WITH THE LOCAL HEALTH DEPARTMENT AND /OR WATER COMPANY AS TO THE METER AND VALVING ARRANGEMENT OF THE DOMESTIC WATER SERVICE LINE WHICH ENTERS THE BUILDING. SHOULD A BACKFLOW PREVENTER ASSEMBLY AND /OR PRESSURE REDUCING VALVE ASSEMBLY BE REQUIRED, THE PLUMBER SHALL FURNISH AND INSTALL SAME PER LOCAL AND STATE REQUIREMENTS. THE BACKFLOW ASSEMBLY SHALL BE A "WATTS" SERIES #909 OR APPROVED EQUAL MEETING ASSE STANDARDS 1013, 1015 AND 1020. IF BACKFLOW PREVENTER IS INSTALLED, PROVIDE PROPERLY SIZED THERMAL EXPANSION TANK IN SUPPLY PIPING OF WATER HEATER. IF WATER PRESSURE IS 65 PSI OR GREATER, A PRESSURE REDUCING VALVE ASSEMBLY SHALL BE A "WATTS" SERIES #25AUB-Z3 OR APPROVED EQUAL SET AT 50 LBS. DELIVERY PRESSURE UNLESS OTHERWISE NOTED. 9 THE WATER PIPING SYSTEM SHALL BE FLUSHED AND STERILIZED IN ACCORDANCE WITH LOCAL REGULATIONS. 1111 11 !FIN (J50 -01) / 1_ / 7 r DOMESTIC WATER PIPING DIAGRAM HAND SINK r (J52 -01) (J60 -01) r 0 3/4" 1/2" / / / / / 3/4" I NOTE: NE WATER SUPPLY CONNECTION TO CARBONATED BEVERAGE DISPENSERS SHALL BE PROTECTED AGAINST BACKFLOW BY A DUAL CHECK VALVE W /ATMOSPHERIC VENT CONFORMING TO NSF STANDARD NO. 25. THE VALVE AND THE PIPING DOWNSTREAM THEREFROM SHALL NOT BE AFFECTED BY CARBON DIOXIDE GAS. A 1I I1 \ r \r \ \ I //I \ 1 \ \\ \ \1 -- i / i \ � \ CONNE [ XISTING 4 7 DOMESTIC - WATER AS REQUIRED. - - I \ / J RISE UP IN LOW WALL INSTALL SHUTOFF VAL AN ACCESSIBLE LOCATI 8" ABOVE FLOOR. 3/4" 1 1 1 / (J50 -01) 1/2" FROM EXISTING 3/4" DOMESTIC COLD WATER PIPING BELOW FLOOR. u IN / / / /// // // ■ 1/2" CW TO INLINE FILTER (J60 -03) MAIN SHUTOFF VALVE FLOOR PENETRATION. SLEEVE & SEAL----..- THRU FLOOR. (TYPICAL) &KA 10. THE POTABLE WATER SUPPLY SHALL BE PROTECTED AGAINST BACKFLOW AND SIPHONAGE BOTH NATURAL AND INDUCED. ALL EQUIPMENT CONNECTED TO THE POTABLE WATER SYSTEM BEING CAPABLE OF POLLUTING OR CONTAMINATING THE POTABLE WATER DISTRIBUTION SYSTEM OR ANY PART THEREOF BY MEANS OF A REVERSAL OF FLOW, PRESSURE DROP, PRESSURE LOSS, INDUCED VACUUM OR BY INJECTION BECAUSE OF ANY PRIMARY OR AUXILIARY PUMPING SYSTEM CONNECTED THERETO MUST BE ISOLATED AND CONTAINED BY MEANS OF APPROVED BACKFLOW DEVICES, CHECK VALVES, AIR GAPS OR VACUUM BREAKERS. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL THESE DEVICES PER LOCAL CODE REQUIREMENTS. 11. THE HOT AND COLD WATER SUPPLY BRANCHES FOR ALL EQUIPMENT HAVING QUICK CLOSING VALVES OF ANY TYPE SHALL HAVE WATER HAMMER ARRESTORS INSTALLED AT THE HIGH POINT ON THE END OF EACH BRANCH. 12. FURNISH AND INSTALL SHUTOFF OR BALL VALVE AND DIELECTRIC UNION ON ALL EQUIPMENT HOT AND COLD WATER LINES. PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT. COORDINATE WITH EQUIPMENT SUPPLIER FOR EXACT REQUIREMENTS. 13. FURNISH & INSTALL 1/2" (MIN.) FIBERGLASS INSULATION WITH ALL-SERVICE JACKET 014 ALL HOT, COLD, RECIRCULATING WATER LINES ABOVE SLAB AND ALL CONDENSATE FROM MECHANICAL UNITS. 14. WATER PIPE AND FITTINGS SHALL BE COPPER OR BRASS PER CODE. ABOVE GROUND SHALL BE TYPE L RIGID COPPER. BELOW GROUND SHALL BE TYPE K SOFT COPPER WITH NO JOINTS PERMITTED BELOW GROUND. ALL JOINTS SHALL BE MADE WITH 95 -5 SOLDER OR EQUAL 15. FURNISH AND INSTALL CONDENSATE LINES FROM ANY MECHANICAL EQUIPMENT AS REQUIRED. ANY CONDENSATE LINE RUN ABOVE THE CEILING OR IN A LOCATION WHERE THE PIPE'S SWEATING COULD CAUSE DAMAGE, SHALL BE INSULATED. RUN FULL SIZE TO DRAIN OR AS INDICATED ON PLANS. TURN DOWN WITH REQUIRED AIR GAP. 16. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL COPPER INDIRECT WASTE PIPING REQUIRED FROM EQUIPMENT TO FLOOR DRAINS, OPEN RECEPTACLES, OR FLOOR SINKS. PIPING SHALL COMPLY WITH STATE AND LOCAL CODES. COORDINATE WITH ALL EQUIPMENT SUPPLIERS AND SIZE AS REQUIRED BY PIECE OF EQUIPMENT SERVED. HOLD PIPING TIGHT TO WALL WHERE APPLICABLE. PROPERLY SECURE AS REQUIRED. COORDINATE WITH CASEWORK SUPPLIER FOR MAXIMUM CLEARANCE UNDER CABINETS. 17. ALL VENT PIPE TO BE COMPATIBLE WITH STRUCTURE, MECHANICAL EQUIPMENT AND DUCTWORK, ELECTRICAL EQUIPMENT AND LIGHTING. 18. PROVIDE CHROME PLATED ESCUTCHEONS AT ALL WALL PENETRATIONS. 19. WASTE AND VENT PIPING SHALL BE CAST IRON. CONTRACTOR MAY USE SCHEDULE 40 OR 80, TYPE 1, GRADE 1, POLYVINYL CHLORIDE COMPOUNDS AS DEFINED AND DESCRIBED IN TENTATIVE SPECIFICATIONS FOR RIGID PVC (ASTM DESIGNATION: D 2665, D 2949, F891 OR SCHEDULE 40 OR 30 ACRYLONITRILE- BUTADIENE - STYRENE COMPOUND AS DEFINED AND DESCRIBED IN STANDARD SPECIFICATIONS FOR ABS (ASTM DESIGNATION: 1 QQ SHEET NOTES O 1 3/4" DOMESTIC WATER SERVICE BY LANDLORD. SLEEVE AND SEAL AT FLOOR PENETRATION. DOMESTIC WATER MAIN SHUTOFF VALVE LOCATION. INSTALL VALVE IN AN ACCESSABLE LOCATION. O INSTANTANEOUS WATER HEATER LOCATED ON WALL UNDER 3 -COMP SINK. WATER PIPING RUNS WITHIN LOW WALL TO COFFEE MAKER AND SODA DISPENSER. VERIFY REQUIREMENTS. COORDINATE WITH WALL STRUCTURE AND EQUIPMENT. O CONNECT CW PIPING TO IN -LINE WATER FILTER BELOW COUNTERTOP. RUN 1/4" FILTERED WATER TO COFFEE BREWER C21 -01 UP THROUGH GROMMIT IN COUNTERTOP. O 4" WASTE PIPING PROVIDED BY LANDLORD TO THIS APPROXIMATE LOCATION. COORDINATE WITH LANDLORD AND CONNECT AS REQD. O 7 1/2" CW PIPING TO IN -LINE FILTER FOR ICE MACHINE. VERIFY CONNECTION REQUIREMENTS FROM FILTER TO ICE MACHINE. 1/2" CW PIPING TO IN -LINE WATER FILTER FOR SODA SYSTEM BY EQUIPMENT SUPPLIER. VERIFY EXACT CONNECTION REQUIREMENTS. EQUIPMENT LIST SEE KITCHEN EQUIPMENT SHEET A1.2 FOR EQUIPMENT SCHEDULE (B60 -07) (C21 -01) (J50 -01) (J52 -01) (J53 -01) (J53 -02) (J60 -01) ( J61 -01) SODA DISPENSER COM-EL BREWER HAND SINK W /FAUCET 3- COMPARTMENT SINK PRE -RINSE FAUCET W /OVERHEAD SPRING ACTION GOOSENECK FAUCET ADD -ON TO PRE -RINSE UNIT FAUCET ICE MAKER ICE BIN GREASE TRAP SIZING REFERENCE 2006 IPC TABLE 1003.3.4.1 DIMENSIONS OF BOWL OF 3- COMPARTMENT SINK TOTAL CAPACITY CAPACITY IN GALLONS (DIVIDE BY 231) ACTUAL DRAINAGE LOAD (75% OF TOTAL CAPACITY) FLOW RATE FOR 1 MINUTE TOTAL POSSIBLE DISCHARGE 3 @ 18 "x18 "x10" (3240 CU IN EACH) 9720 CUBIC INCHES 42.07 GAL 31.55 GAL SAY 32 GPM 32 GPM REQUIRED RATE PERMIT FOR: Sifinethanicat cEr Electrical ❑ Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION D2661 OR F 628) IN LIEU OF CAST IRON WASTE AND VENT PIPING IF PERMITTED BY CODE. INSTALL PVC OR ABS PIPING PER CODE. PLUMBING CONTRACTOR SHALL INSTALL 4" SOIL WASTE AND GREASE WASTE PIPING WITH A MINIMUM SLOPE OF 1/8" PER FOOT OR AS REQUIRED BY CODE. 20. HOLD TOP OF FLOOR DRAINS FLUSH WITH FINISHED FLOOR. SEE ARCH. SHEETS FOR FLOOR SLOPES AROUND DRAINS. (IF REQ'D) 21. MATERIALS, EQUIPMENT, ASSEMBLIES AND SYSTEMS SHALL MEET ALL PERTINENT REQUIREMENTS OF NATIONALLY RECOGNIZED TESTING ORGANIZATION SUCH AS THE UL, ASTM, ASSE, AWWA, AGA AND NFPA AS WELL AS THE MOST CURRENT VERSION OF THE STATE CODE AND LOCAL AMENDMENTS. 22. ALL INSTALLED SYSTEMS, DEVICES AND RELATED ITEMS SHALL BE TESTED IN PLACE ON SITE PER LOCAL CODE REQUIREMENTS. REPLACE ANY AND ALL CONTRACTOR SUPPLIED DEFECTIVE DEVICES, ITEMS OR SYSTEMS AT CONTRACTOR'S OWN EXPENSE BEFORE COMPLETION OF PROJECT. 23. WHERE JOB CONDITIONS REQUIRE CHANGES FROM THE CONTRACT DOCUMENTS THAT DO NOT CHANGE THE SCOPE OR NATURE OF THE WORK REQUIRED, THE CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT ADDITIONAL COST TO THE OWNER. NO OTHER CHANGES MAY BE MADE WITHOUT WRITTEN PERMISSION OF THE OWNER. 24. ALL EQUIPMENT, FIXTURES AND MATERIALS SHALL BE NEW AND UNUSED, AND INSTALLED IN STRICT CONFORMANCE TO MANUFACTURER'S RECOMMENDATIONS (U.O.N.). PROVIDE COMPLETE WITH ALL TRIM, STOPS, HANGERS, CARRIERS, SUPPORTS, ETC. INCLUDING PROVISIONS FOR BARRIER FREE USE, IF REQUIRED. WHERE FIXTURES ARE ACCESSIBLE, THEY MUST COMPLY WITH ALL FEDERAL A.D.A. REGULATIONS. 25. CONTRACTOR SHALL GUARANTEE ALL WORK FOR WHICH MATERIALS ARE FURNISHED, FABRICATED OR FIELD ERECTED, ALL FACTORY ASSEMBLED EQUIPMENT FOR WHICH NO SPECIFIC MANUFACTURER'S GUARANTEE I5 FURNISHED AND ALL WORK IN CONNECTION WITH THE INSTALLATION OF MANUFACTURER'S GUARANTEED EQUIPMENT. THIS CONTRACTOR'S GUARANTEE SHALL EXIST FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL OWNER ACCEPTANCE OF THE WORK AND SHALL APPLY TO ALL DEFECTS IN MATERIALS AND /OR WORKMANSHIP OF ANY KIND. 26. BIDDERS SHALL BE LICENSED CONTRACTORS IN ACCORDANCE WITH LOCAL AND AND STATE LAWS. 27. ALL PERMITS AND FEES REQUIRED FOR THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR AND INCLUDED IN THE BID PRICE. 28. ALL PLUMBING FIXTURES AND PIPING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF STATE AND /OR LOCAL CODES. COOPERATE AS REQUIRED WITH ALL AUTHORITIES HAVING JURISDICTION TO INSURE THAT PROPER MATERIALS AND WORKMANSHIP ARE USED. REQUIREMENTS OF STATE AND LOCAL CODES AND AUTHORITIES TAKE PRECEDENCE OVER ANY INFORMATION WHICH IS INDICATED OR IMPLIED ON THESE DRAWINGS. Permit No. ISLAND VENT INSTALLATION RISES UP TO ABOVE THE FLOOD RIM OF ALL FIXTURES CONNECT ISLAND VENT TO EXISTING 3" VENT PIPING AS REQUIRED EXISTING 3" VENT UNDER FLOOR FLOW CONTROL FITTING VENT EXISTING 4" WASTE UNDER FLOOR -�� COORDINATE WASTE AND VENT PIPING WITH ELECTRIC PANEL, SEE SHEET E1.0 FOR LOCATION FILE COPY 0 Mar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code orordinance. Receipt o' approved Field try and conditkan is adurowl : By, Date : 7 / 7 ~� City of Tukwila BUILDING DIVISION O NOTE: SEE WASTE AND VENT PIPING DIAGRAM, THIS SHEET, FOR PIPE SIZE INFORMATION. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division, NOTE: Revisions will require a new plan submittal and may include additional plan review fees. NOTE: NO WORK AT REMOTE STORAGE REQUIRED. WALK -IN BOX TO BE FURNISHED WITH AUTOMATIC CONDENSATE EVAPORATOR. MARK EXISTING 4" WASTE PIPING 29. THIS SYMBOL ( PXX ) INDICATES ITEM TO BE FURNISHED BY OWNER OR KITCHEN EQUIPMENT SUPPLIER. COORDINATE INSTALLATION AND FINAL CONNECTION REQUIREMENTS WITH SUPPLIER. FIELD VERIFY SIZES AND LOCATIONS OF ALL SUPPLIER. FIELD VERIFY SIZES AND LOCATIONS OF ALL WATER, WASTE, INDIRECT WASTE, GAS AND /OR ELECTRICAL CONNECTIONS PRIOR TO INSTALLATION (TYPICAL ALL PLUMBING EQUIPMENT). 30. SEE PLUMBING ROUGH -IN DRAWINGS PROVIDED BY KITCHEN EQUIPMENT SUPPLIER FOR MORE INFORMATION. 31. ALL INDIRECT WASTE, WASTE PIPING OR FIXTURE WHICH RECEIVES THE DISCHARGE FROM A DISHWASHER, STEAMER OR SIMILAR PIECE OF EQUIPMENT WHICH PRODUCES SIMILAR PIECE OF EQUIPMENT WHICH PRODUCES WATER AT A TEMPERATURE HIGHER THAN 125F SHALL BE DWV COPPER OR CAST IRON A MINIMUM OF 10' -0" DOWNSTREAM FROM THE OUTLET PRODUCING SUCH DISCHARGE. COORDINATE WITH KES. 32. ALL INDIRECT WASTE PIPING FROM EQUIPMENT TO ABOVE FLOOR RECEPTOR SHALL BE 1" (MIN.) COPPER UNLESS LARGER SIZE IS INDICATED BY EQUIPMENT OPENING OR KES. r L MI lI II I i 111 111111 110: l - WU. (B60-07) REVIEWED COMPLIANCE MPLIANCE APPROVED JUL 11 2008 EXISTING 3" VENT PIPING y Of Tukwila BUILDING DIVISION FIXTURE INSTANTANEOUS ELECTRIC WATER HEATER FLOOR DRAIN FLOOR SINK GREASE INTERCEPTOR TO ter■ �,.�- J 111.9 /// NO SCALE 01 (J52-01) 1 1 1 I 1 1 ( C21 -01) �T FIXTURE DATA MANUFACTURER * EEMAX • J.R.SMITH * J.R.SMITH * J.R.SMITH 111 1MI III III * OR APPROVED EQUAL - 3 --COMP SINK r-To 1 1 /2 " Q SCALE: 1 /2" = Q4 o , o% Ste (J50 -01) NitIINl III 1illl llIIII IIIYIIIIII III 0 CONNECT TO ESISTING 4" WASTE NEW VENT PIPING NEW COLD WATER PIPING NEW HOT WATER PIPING NEW INDIRECT WASTE PIPING NEW CONDENSATE DRAIN PIPING EQUIPMENT NUMBER PLUMBING FIXTURE NUMBER CATALOG N0. EX180T2T 2005- A -PB -U 3100 8035 COLOR -HAND SINK , L____ / / r I � I 1 WASTE & VENT PIPING DIAGRAM NEW SOIL, WASTE OR GREASE WASTE PIPING SOIL SIZE OT 0 -01 NMI II�I�111 [Q 1 - VENT SIZE __ J 3" PLUMBING LEGEND NOTE: ALL SYMBOLS MAY NOT APPEAR IN THESE DRAWINGS 0 AFF PLUMBING FIXTURE SCHEDULE CONNECTION DATA COLD /I nr1 i I 1 /\ \ 7L -Y- -t-3 / i \ \ L-- r r .- 1 __., WATER HOT (J52 -01) TEMP. 1 WASTE AND VENT FLOOR PLAN • ONNECT TO EXISTING WASTE PIPING VERIFY EXACT LOCATION AND CONN. REQUIREMENTS. (TYP.) DROP VENT PIPING INTO TOP OF EXISTING 3" VENT PIPING. UNION CHECK VALVE /BACKFLOW PREVENTER BALL VALVE NEW FLOOR SINK NEW FLOOR DRAIN CLEANOUT ABOVE FINISHED FLOOR SHEET TAG NOTE SIZE PER FLOW CONTROL FITTING CONNECTION T HIGH POINT OF ISLAND VENT PIPING T,, I F" I `, :------- 11/2" 1 (J50 -01) " REMARKS " 3" RECEIVED t WILL CITY JUN 0 5 200E PERMIT CENTER INSTANTANEOUS ELECTRIC MODEL, 208V, 30, 18KW, 50 AMP PER 3 /4" 3 /4" - -- PHASE. 2 GPM AT 61' RISE. STAGED TURN ON. THERMOSTATIC CONTROLLER TO DELIVER WATER AT MAXIMUM TEMP. OF 120'F. 6" DIA. POLISHED BRONZE STRAINER, MEMBRANE CLAMP, SPEEDI -SET, VANDAL PROOF SCREWS. 8 SQ. TOP, 6" DEEP, DOME STRAINER. HALF OR 3/4 GRATE AS INDICATED ON PLANS 35 GPM FLOW, 70 LBS GREASE CAP. FLOW CONTROL FITTING. PROVIDE WITH EXTENSION FOR CORRECT ROUGH IN DEPTH. SIZE: 32 "x18 "x21 ", SITTING ON FLOOR.