Loading...
HomeMy WebLinkAboutPermit PG08-216 - MINUTE MAN PRESSMINUTE MAN PRESS 340 ANDOVER PK E PGO8-216 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: DESCRIPTION OF WORK: 0223200032 340 ANDOVER PK E TUKW MINUTE MAN PRESS 340 ANDOVER PK E , TIJKWILA WA ROSELLINI ALBERT D 5936 6TH AVE S , SEATTLE WA MARK SUTIN 206 AVE G , SNOHOMISH WA Contractor: Name: THE PLUMBERS Address: 206 AV G , SNOHOMISH WA Contractor License No: PLUMB ** 151 JR Value of Plumbing /Gas Piping: $0.00 Uniform Plumbing Code Edition: Fees Collected: $139.00 Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 0 Shower, single head trap 0 Lavatory 0 Wash fountain Receptor, indirect waste 0 Sinks 1 Urinals 0 Water Closet 0 doc: UPC -10/06 Cityif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us FIXTURE TYPE AND OUANTITY 0 * *continued on next page ** PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 360 - 840 -0120 Phone: 360- 568 -3880 Expiration Date: 01/29/2009 PG08 -216 08/11/2008 02/07/2009 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and/or vent 0 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 1 Medical gas piping (6 +) inlets /outlets 1 Gas Piping Gas piping outlets (0 -5) 0 Gas piping outlets (6 +) 0 PG08 -216 Printed: 08-11 -2008 Permit Center Authorized Signature: City ("Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ;r/f,1 -c (/()21-z/6( Permit Number: PGO8 - 216 Issue Date: 08/11/2008 Permit Expires On: 02/07/2009 Date: bc� � `� 6V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perf • anc - • f , rk. I . ,! aut um rized to sign and obtain this plumbing /gas piping permit. `L -mil _i r Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 Date: c " ! f PG08 -216 Printed: 08 -11 -2008 Parcel No.: 0223200032 Address: Suite No: Tenant: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 340 ANDOVER PK E TUKW MINUTE MAN PRESS 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG08 -216 ISSUED 07/31/2008 08/11/2008 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG08 -216 Printed: 08 -11 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. • / -_ uJ mime Signature: Print Name: M I'YV ` )C doc: Cond -10/06 • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: ` ll -08 PG08 -216 Printed: 08 -11 -2008 SITE LOCATION Site Address: CITY OF TUKWIL I Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 3e- 4- I41)07/�� Tenant Name:) /-441-AI tz_ © �. New Tenant: .... Yes J ..No Property Owners Name: /�M-4 4GE Adi ]���7�> ae Mailing Address: ! / N, L'$ y CONTACT PERSON -Who do we contact when your permit is ready to be issued Name: /V( !'t�� Ur) V Mailing Address: 6 4tJ G- A'O//O 1 J5/j -- City State Z' E -Mail Address: /1 S (i A4 �`/CJI s tai /VtT Fax Number: �O 26 ,) PLUMBING / GAS PIPING CONTRACTOR INE(:1RMATIO] Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: p le L. 6- sv ) Y/ S 07 en� 1 . 7 Q eo r Registration Number: . P2._ j> �4� Contractor Registra Q:\Applications\Porms- Applications On Line \3 -2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4 -2006 bh Plumbing /Gas Permit No. 4W O 9- ((� Pro No. For of ce ;rise only) King Co Assessor's Tax No.: n�� �� 00 3� Suite Number: City State State Floor: Zip Day Telephone: N» n I s - r�q- 9 2yo City State Zip Day Telephone: 360 g -)0 0/ 20 Fax Number: 3 S°63 6 Expiration Date: ARCHITECT OE RECORD - All pian miu."st be wet s tamped by Arbite of Recort U DV MC P vt.ir aJ 1,04- q'cg /3 City State Zip Day Telephone: 0Z .5 7- 7 /Zo Fax Number: e wet'stamped by,Engineer ot City Day Telephone: Fax Number: Zip Page 1 of 2 Fixture Type; Qty Fixture Type: Qty ;' Fixture Type: Qty Fixture Type Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks / Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment j Repair or alteration of drainage or vent piping ) Y Medical gas piping system serving one to five inlets/outlets for specific gas BUILDING OWNER R AU Signature:_ Print Name: ZED rik Valuation of Project (contractor's bid price): $ Ono Scope of Work (please provide detailed information): Y.E EC-t-- t N Building Use (per Int'l Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Mailing Address: ,J::) A- E._ - A s U ' T 1 Q:\Applications\Fonns- Applications On Line \3 -2006 - Plumbing -Ges Piping Permi Application. doc Revised: 4 -2006 bh Date: 3 i Day Telephone: 36 (g 5 0 I ZD kOMD M 1317 w, g63290 City State Zip I Date Application Accepted: - 7 -3[-08 Date Application Expires: s I �y Staff Initials: / k Page 2 of 2 Parcel No.: 0223200032 Address: 340 ANDOVER PK E TUKW Suite No: Applicant: MINUTE MAN PRESS Receipt No.: R08 - 02810 Initials: WER User ID: 1655 Payee: THE PLUMBERS TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 139.00 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES PLUMBING - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/345.830 23.00 000.322.103.00.0 116.00 Total: $139.00 Permit Number: PG08 -216 Status: PENDING Applied Date: 07/31/2008 Issue Date: Payment Amount: $139.00 Payment Date: 07/31/2008 03:23 PM Balance: $0.00 5524 08 /01 0710 TOTAL 139.00 doc: Receiot -06 Printed: 07 -31 -2008 Project:: /i )794w /)794w O /7/,-tr7 / )794w b�l 'S Type of Inspection: % �A., .9 / Address: 3 L/) 42 'vdww/ i)e f Date Called: Special Instructions: .�kk Date Wanted: /4 "/V °e p.m. Requester: Phone No: — may - VZ/ 4° Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Corrections required prior to approval. COMMENTS: 4' at .00 REINSPECTION F : E REQ !RED. Prior to inspection, fee must be id at 6300 Southcente Blvd. uite 100. Call to schedule reinspection. R eipt No.: 'Date: COMMENTS: of Ins ction: s d�c� l — ti C Address: - 3 L U (1,J( (Ne u Date Called: 6,r J U r.1 LAJ $C. 9 Special Instructions: Zr Date anted: Ci,u1.. Requester: Ph eCN 9,-(c)-0/26 0 ` ke —A-rJ Di) As 5-0 °�,' 04 / el J Jr, l 2.,'?., sr, De DA M S- e ,,e'), 4.. LJs-. p — (_ j .l1.i1<< / L.J& l Project: . 4 I rv1( -1 G IA P fe of Ins ction: s d�c� l — ti C Address: - 3 L U (1,J( (Ne u Date Called: 6,r J U r.1 LAJ $C. 9 Special Instructions: Zr Date anted: Ci,u1.. Requester: Ph eCN 9,-(c)-0/26 P63g -2/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Z A pproved per applicable codes. 0 Corrections required prior to approval. Inspectoy Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: DEPARTMENTS: �ul ding�Division Complete Comments: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 WORD COPY o PLAN REVIEW /ROUTING SLIP rf ACTIVITY NUMBER: PG08 -216 PROJECT NAME: MINUTE MAN PRESS SITE ADDRESS: 340 ANDOVER PK E X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DATE: 07 -31 -08 Revision # After Permit Issued APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Fire Prevention Public Works Structural ❑ Permit Coordinator n 6-DP' ERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08-05-08 Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required n No further Review Required ❑ n DATE: DATE: Planning Division Not Applicable n n DUE DATE: 09-02 -08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 TRAVELERS CAS & SURETY 206085397 02/19/2002 Until Cancelled $12,000.0012/14 /2001 4 RELIANCE SURETY CO 6085397 02/19/1998 Until Cancelled 02/19/2002 $6,000.00 3 RELIANCE SURETY CO 6085397 02/19/199702/19 /1998 $6,000.00 2 TIG SPECIALTY INS CO A1C324907402/19/199202/19/1997 $6,000.00 1 NEW SOUTH INS CO 112359 02/19/198502/19 /1992 $6,000.00 Name Role Effective Date Expiration Date SUTIN, MARK D OWNER 04/19/1985 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. PLUMBERS, THE Business and Licensing Information Name PLUMBERS, THE UBI No. 600564790 Phone 3605683880 Status ACTIVE Address 206 AVE G License No. PLUMB * *151JR Suite /Apt. License Type CONSTRUCTION CONTRACTOR City SNOHOMISH Effective Date 4/19/1985 State WA Expiration Date 1/29/2009 Zip 98290 Suspend Date County SNOHOMISH Separation Date Business Type INDIVIDUAL Previous License MECON* *20304 Parent Company Next License Associated License Specialty 1 GENERAL Specialty 2 UNUSED Business Owner Information Bond Information • 0 https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= PLUMB ** 151 JR Page 1 of 3 08/11/2008 Lighting Summary LTG —SUM 2004 Project Info Project Address MINUTEMAN PRESS Date 04/15/08 340 ANDOVER PARK EAST For Building Department Use TUKWILA, WA 98188 Applicant Name: BURGESS DESIGN INC. Applicant Address: 1326 FIFTH AVENUE, 1500, SEATTLE, WA 98101 Applicant Phone: 206 587 7120 Project Description ❑ hew Building 0 Addition LO Alteration Compliance Option ❑ Prescriptive w Lighting Power Nlowonce ❑ Systems Analysis (Sae Quolificotfon Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) 0 Ho changes are being code to the lighting (0 Less than 60% of the fixtures are new and installed lighting wattage is not being increased CEILING LEGEND - LIGHTING I SYMBOL SYMBOL EQUIP 2 MICROWAVE (BY TENANT) DESCRIPTION /SPEC EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN. EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE REMOVED. NEW SWITCH LOCATION. TWO -WAY SWITCH LOCATION. VIENT LIST REFLECTED CEILING PLAN 0 8' 16' 24' DESCRIPTION = NEW R R = RELOCATED CEILING LEGEND - CONTROLS NEW EXIT SIGN. COORDINATE FINAL LOCATION WITH CODE OFFICIAL. RELOCATED 2' X 4' FLUORESCENT FIXTURE. - VERIFY ALL REQUIREMENTS WITH TENANT UNDER COUNTER REFRIGERATOR (BY TENANT, G.C. TO PROVIDE COPPER WATER LINE AND HOOK UP ICE MAKER AS REQ'D) 1/8" e 1'— 0" FINISH SPECIFICATIONS SYMBOL BASE 8 -1 CARPET CPT —I PAINT P -1 I PL -1 PL--2 MANUFACTURER FLEXCO PHILADELPHIA TBD PLASTIC LAMINATE TBD TBD DESCRIPTION 4 "h STRAIGHT RUBBER BASE. COLOR: TBD FIELD CARPET / 26 OUNCE COLOR: TBD INSTALLED: DIRECT GLUE GWB EGGSHELL FINISH COLOR: TBD ( POWER 8( DATA PLAN 0 8' 16' 24' PLASTIC LAMINATE HORIZONTAL SURFACES /BACKSPASH. LAMINATE COLOR: TBD PLASTIC LAMINATE VERTICAL SURFACES LAMINATE COLOR: TBD INTERIOR MELAMINE: TBD WALL MOUNTED DEVICES SYMBOL DESCRIPTION I Q JUNCTION BOX EX STING TO REMAIN DUPLEX OUTLET QUADRAPLEX OUTLET DUPLEX OUTLET (# DENOTES MOUNTING HT IN INCHES) DEDICATED DUPLEX OUTLET VOICE & DATA COMBINATION OUTLET BLANK COVER PLATE MISC. NOTATION DENOTES A NEW DEVICE - rNT rt Prd V� "C .. N�, �oF� Ur /ah 443,4 1-14 1?..oVer - ttPow 1/8" = 1,.- 1, O r o Cb M SEPARATE PERMIT REQUIRED FOR: Wptechanical ectrical O Plumbing O Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submit tl and may include additional plan review fees. 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 4. FURNITURE SHOWN FOR INTENT ONLY, FINAL LOCATION OF FURNITURE AND OUTLETS TO BE COORDINATED WITH TENANTS FURNITURE VENDOR. VERIFY ELECTRICAL AND VOICE /DATA REQUIREMENTS WITH TENANT. 5. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 6. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEILING PLAN DESIGN. 7. LIGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. 8. UNLESS NOTED OTHERWISE, MULTIPLE SWITCH'S IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX AND COVERED WITH A SINGLE COVERPLATE. 9. CLEAN, REPAIR OR REPLACE AS REQUIRED ALL EXISTING SUSPENDED CEILING GRID AND TILES EXISTING TO REMAIN. 10. HVAC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY /RETURN GRILLS PRIOR TO COMPLETION OF PROJECT. 11. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES TO BE RELOCATED. 12. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR PROVIDING CUT SHEETS TO DESIGNER FOR ALL FIXTURES DESIGNATED AS NEW. KEYED SHEET NOTES FINISH NOTES LIGHTING SUMMARY GENERAL RCP /POWER /DATA NOTES 2. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE WORKING CONDITION OF ALL EXISTING OUTLETS NOTED TO REMAIN. 3. ALL OUTLETS SHOWN ARE APPROXIMATE. DUE TO HIDDEN CONDITIONS ADDITIONAL P /P /D MAY EXIST BUT NOT BE REFLECTED ON THE PLANS. • RE-ROUTE SWITCHING SO THAT ALL SWITCHES ARE CONTROLLED FROM WITHIN THE SUITES THEY SERVE. 0 , CEILING OUTLET FOR NEON SIGN. VERIFY LOCATION WITH TENANT. 4 CONTRACTOR SHALL DETERMINE IF ELECTRICAL CONDUIT CAN BE PLACED IN WALLS OR PROVIDE OUTLETS IN RIGID CONDUIT. VERIFY WITH BUILDING MANAGEMENT. 1. VERIFY ALL FINISHES WITH BUILDING MANAGEMENT AND OTHERS. 2. PROVIDE B -1 THROUGHOUT, UON. 3. PROVIDE P -1 THROUGHOUT, UON. 4. PROVIDE CPT -1 THROUGHOUT, UON. 5. REFER TO ELEVATIONS AND DETAIL SHEETS. 6. CENTER TRANSITION BETWEEN MATERIALS UNDER DOOR PER DETAILS. t( \ 1zVVED FOR CODE COMPLIANCE APPRO`* ; ED r NG - 5 700a Cif C9f T it � � � :!'N 2004 Washington State Nonresidential Energy Code Compliance Form ?Goa 2U' RECEIVED JUL 312000 PERMIT CENTER Tenant: MINUTEMAN PRESS ANDOVER EXECUTIVE PARK 340 ANDOVER PARK EAST, BUILDING 2, #360 ALSO KNOWN AS 596 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BUILDING 9 617 INDUSTRY DRIVE TUKWILA, WA 98188 Drawn by: PN Minuteman P ress,. rrrTEM Mtrrortlara, ,*.t y Law Swop ir► . burgess design I interiors 0 architecture I97; Flrth knout Suitt 600. Sank . WA 116101 1EE: 900.6 *7.7190 FAX:904. $*7.7179 All reproduction & intellectual property rights reserved c 2008 FILE COPY Permit No. Plar review approval is subject to en • rs and omissions. Approval of construction documents does nrt 2 0 se al the violation of any adopted code or • rdinance. Receipt of approved Fietd Copy an0 a 1 is acknowledged: By 08 Date: �-1-- C ity Q# Tukwil i f TING DMS N No. Issue Description REVIEW SET Project No: 08-3403-00 Reviewed by: KK Date 4/15/08 POWER & DATA / FINISH REFLECTED CEILING PLANS Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.2B.1 P —LAM COUNTERTOP BACKSPLASH EQ. EQ. EQ. ADA COMPLIANT SINK & FAUCET A.9.1 3' CLR. UNDER COUNTER REFRIGERATOR BY TENANT BREAK AREA ELEVATION P —LAM LOWER CABINETS AND DRAWER WITH ONE ADJUSTABLE SHELF 8 9 3/8 = 1,_ 0" 3/8" = 1' 11 Ec 3/8" = 3/8" = 1'_ 3/8" = 1 ,_ 0 " 3/8 = 1 ,_ 0 " EVIbWWW FORR i CODE COMPLIANCE APPROVED AUG - 5 2000 City Of Tukwila BUILDING DIVISION 3/8 _ 1 , 0 " PG00w2.1 RECEIVED JUL 3 1 2008 PERMIT CENTEF @ ? PiVSS . *TErnaM �1r, .. tt Or Professional seal Project No: 08- 3403 -00 Minuteman Tenant: MINUTEMAN PRESS ANDOVER EXECUTIVE PARK 340 ANDOVER PARK EAST, BUILDING 2, #360 ALSO KNOWN AS 596 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BUILDING 9 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design I Inte riors Q architecture 172! Fifth Amu! SuItt 109. Swlde . WA 10101 IEkf 201417.7M FA%1 04. 5$7.7171 All reproduction & intellectual property rights reserved c 2908 No Issue Description Date REVIEW SET 4/15/08 Drawn by: PN Reviewed by: KK INTERIOR ELEVATIONS Original drawing is 24" x 36 ". scale entities accordingly if reduced A.6.1 DOOR SCHEDULE DOOR 8c HARDWARE GENERAL NOTES 1. SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION. 2. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME HEAD. REFER TO SPECIFICATIONS FOR CLEARANCES. 3. DOUBLE DOOR NOMINAL WIDTH INDICATES 2 DOOR LEAVES OF EQUAL WIDTH, U.O.N. 4. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH — BOLTS. 5. DOOR / HARDWARE SHALL COMPLY WITH ALL APPLICABLE IBC & ACCESSIBILITY REQUIREMENTS. HARDWARE GROUP HARDWARE GROUP 1 PASSAGE LATCHSET (1-1/2) PAIR HINGES 1 WALL — MOUNTED DOOR STOP 1 OFFICE FUNCTION LOCKSET (1 -1/2) PAIR HINGES 1 WALL — MOUNTED DOOR STOP REMARKS DOOR TYPES FRAME MATERIAL & FRAME FINISH TO MATCH SUITE STANDARD FLUSH S.C. WOOD DOOR — DOOR FINISH TO MATCH SUITE STANDARD E = EXISTING, MATCH ALL EXISTING CONDITIONS 'O ! Rea ED CODE. COMPLIANCE APP Pr. °�J BUG - ' 7.0 City Orculimila BUILDING ONISION GROUP E EXISTING HARDWARE GROUP 1 SINGLE, PASSAGE LATCHSET NON —RATED GROUP 2 SINGLE, OFFICE LOCKSET NON —RATED SIDELIGHT /GLAZING SCHEDULE SIDELIGHT HARDWARE 1/4" TEMPERED SIDELIGHT /GLAZING TYPES WIDTH 1/4" TEMPERED FRAME & FINISH TO MATCH SUITE STANDARD GLAZING AS SCHEDULED E = EXISTING, MATCH ALL EXISTING CONDITIONS RECE JUL 3 PARTITION INTERSECTION DETAIL 0 " 4 " 8 " r L 6" MAX, 2' -1" TYP. ADA SINK SECTION • / l 8" PAPER CORNER REINFORCEMENT, TIP, ACOUSTIC INSULATION AS REQUIRED METAL STUDS 5/8" GYP. BOARD 12" CONTERTOP W /PLASTIC LAMINATE PER FINISH SCHEDULE _ sly j 1 12" LINE OF CEILING PROVIDE SOLID PANEL PLUMBING BOOT AS REQ'D FINISH FLOOR LINE. RUN TO REAR OF CABINET OPENING. PROVIDE 4" BACKSPLASH AS INDICATED ON ELEV. SCRIBE TO WALL PROVIDE SINK WHERE INDICATED — REFER TO PLUMBING DWGS PROVIDE ADA COMPLIANT SINK (Sc FAUCET. PROVIDE CLEARANCES. BASE AS PER SCHEDULE. TURN INSIDE 0 CABINET OPENING, TYP. LINE OF CABINET (BEYOND) 1 "_ co I r DEVICES SHOWN STACKED IN PLAN ARE TO ALIGN VERT. AS SHOWN BELOW M 1. LOCATED SWITCHPLATES, ELECTRICAL AND TELEPHONE WALL OUTLETS AT NEAREST STUD FROM SCALED LOCATION ON PLAN, UNLESS SPECIFICALLY DIMENSIONED ON PLAN, ELEVATION, OR LOCATION AS PER DIAGRAM ABOVE. 2, CENTER FIRE ALARM STROBES DIRECTLY ABOVE FIRE EXTINGUISHER CABINETS WHERE BOTH OCCUR. GENERAL DEVICE ALIGNMENT 11 _ I 1 1) • Wu) BOTTOM OF STRUCTURE PROVIDE ENCAPSULATED ACOUSTICAL BATT EXTENDING 24" EACH SIDE OF PARTITION. 8" AT LOCATION AS DIMENSIONED ON PLAN; OR NEXT TO DOOR / OPENING AS DIMENSIONED BELOW FIRE ALARM STROBE FRAME WHERE OCCURS ROOM SIGNAGE, ETC, THERMOSTAT LIGHT & PROJECTION SCREEN SWITCHES, WALL MOUNTED OCCUPANCY SENSOR CARD READER WHERE OCCURS HARDWARE LATCH FINISHED FLOOR TELEPHONE OUTLET ELECTRICAL OUTLET 12" tIOIS, 6, A 401,‘.. Ari 11111111 n ummmr�rm Mil rwmp, 8" 12" 2 "X2 "X12" MIN. LEG AT STRUCTURE — ATTACH W/2 POWDER DRIVEN FASTENERS PER BRACE OR OTHER APPROVED METHOD PLENUM HEIGHT OF 5' -0" OR LESS 2 1/2 "x25 GA METAL STUD BRACING 0 8' -0" OC TO STRUCTURE DIRECTION ALTERNATE. PARTITIONS PERPENDICULAR TO PARTITION ACT AS BRACE PLENUM OF 5-0" TO 10' -0" SHALL USE NESTED OR BACK TO BACK 3 -1/2" 25 GA. STEEL STUDS. ABOVE 10' -0" OR PLENUM. CONTACT ARCHITECT FOR ADDITIONAL INFORMATION. MAX PARTITION WEIGHT 151bs. /P.S.F. SUSPENDED CEILING AS SCHEDULED VERIFY B/S HEAD CONDITION 3/8" CONT. FOAM SOUND ISOLATION TAPE TAPEABLE MET. TOP TRACK ATTACHED TO BRACING W/2 SELF — TAPPING SM. SCREWS 0 48 "oc, AND 3/4" PIPE SLEEVES INSULATION 2 1/2" X 25 GA METAL STUDS 0 24" OC, TO 10' -9" MAX. HEIGHT. 1 LAYER 5/8" TYPE "X" GYP. BD. EA. SIDE OF METAL STUDS POWER DRIVEN FASTENER 0 24" OC MET. RUNNER TRACK SEALANT CONCRETE SLAB 3 11 = 1 '_ 0 " NON -RATED FLOOR TO CEILING PARTITION ) 11 L 0" CROSS RUNNER MAIN RUNNER DISTANCE FROM BRACING WIRES TO CROSS RUNNERS L 3 STUDS MIN, 1 NOTE: COORDINATE ANCHOR BRACKET LOCATIONS W/ CASEWORK & EQUIPMENT WHERE SCHEDULED, AND MANUF. MOUNTING INSTRUCTIONS TYPICAL ANCHOR BRACKET FRAMING c }LL 0" 4" 12 GA. BRACING WIRE WITH MINIMUM 4 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE —TYP. 8 " NOTE: PROVIDE ACT SUSPENSION GRID TO COMPLY WITH IBC SECTION 1621 MINIMUM STANDARD PER SECTION 9.6 ASCE7. VERIFY REQUIREMENTS WITH CITY OFFICIALS NOTES: 1. TYPICAL ANCHOR BRACKET ASSEMBLY FOR HANDRAILS, GRAB BARS & TOILET ACCESSORY ANCHORAGES. 2. COORDINATE ANCHOR BRACKET LOCATION WITH ACCESSORY MANUFACURER MOUNTING INSTRUCTIONS. ACT SEISMIC BRACING DIAGRAM ACT SEISMIC BRACING 12" BOTTOM OF FINISHED CEILING ANCHOR BRACKET: 6 "X16ga UNPUNCHED STUD TRACK, ATTACH TO 3 STUDS MIN FINISHED FLOOR PROVIDE MIN 25 GA STUDS & ANCHOR BRACKET ANCHORAGES. DOUBLE STUDS 0 END OF PARTITIONS. 3—#8 PAN HEAD SHT. MTL. SCREWS 6 "x16 GA UNPUNCHED STUD TRACK WITH FLANGES COPED AT VERTICAL STUDS. ATTACH TO TWO STUDS MIN. & EXTEND 6 "MIN BEYOND MOUNTING POINT EACH DIRECTION. 12 GA. VERTICAL HANGER WIRE AT 4'-0" EACH WAY WITH MINIMUM 3 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE DIAGRAM 311 = 1) -01) NTS SEISMIC COMPRESSION STRUT A NTS ?Gofr uo v , E �.,. 2006 ENTE° Professional seal Project No: 08- 3403 -00 Minuteman Press. ss. R A M. PIM 4 Lote Slip in Ninthly. Tenant: MINUTEMAN PRESS ANDOVER EXECUTIVE PARK 340 ANDOVER PARK EAST, BUILDING 2, #360 ALSO KNOWN AS 596 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BUILDING 9 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design 'interiors 0 architecture 172 iirlh Atus Suite Foq . 5s.lUt . WA 11101 1(l: 701.117.712o FAX4o1. 117,7177 All reproduction & intellectual property rights reserved c 2008 No. Issue Description Date REVIEW SET 4/15/08 Drown by: PN Reviewed by: KK DOOR SCHEDULE / SIDELIGHT SCHEDULE / DETAILS Original drawing is 24" x 36 Scale entities accordingly 4 reduced A.9.1 MINUTE MAN PRESS 340 ANDOVER PK E PGO8 -216 Parcel No.: Address: Suite No: Cityif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 0223200032 340 ANDOVER PK E TUKW Permit Number: Issue Date: Permit Expires On: PG08 -216 08/11/2008 02/07/2009 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: MINUTE MAN PRESS 340 ANDOVER PK E , TIJKWILA WA ROSELLINI ALBERT D 5936 6TH AVE S , SEATTLE WA MARK SUTIN 206 AVE G , SNOHOMISH WA Contractor: Name: THE PLUMBERS Address: 206 AV G , SNOHOMISH WA Contractor License No: PLUMB ** 151 JR Phone: Phone: 360 - 840 -0120 Phone: 360- 568 -3880 Expiration Date: 01/29/2009 DESCRIPTION OF WORK: Value of Plumbing /Gas Piping: $0.00 Uniform Plumbing Code Edition: Fees Collected: $139.00 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND OUANTITY Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 0 Shower, single head trap 0 Lavatory 0 Wash fountain Receptor, indirect waste 0 Sinks 1 Urinals 0 Water Closet 0 0 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and/or vent 0 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 1 Medical gas piping (6 +) inlets /outlets 1 Gas Piping Gas piping outlets (0 -5) 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -216 Printed: 08-11 -2008 City ("Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PGO8 -216 Issue Date: 08/11/2008 Permit Expires On: 02/07/2009 Permit Center Authorized Signature: Date: bj / I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perf • anc - •f , • rk. I . ,! aut • rized to sign and obtain this plumbing /gas piping permit. Signature: Print Name: Ai / - 2 R b, Date: c " ! f This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -216 Printed: 08 -11 -2008 Parcel No.: 0223200032 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 340 ANDOVER PK E TUKW MINUTE MAN PRESS PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -216 ISSUED 07/31/2008 08/11/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -216 Printed: 08 -11 -2008 • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. • Signature: Print Name: M NR_ )C Date: F3` it -o8 doc: Cond -10/06 PG08 -216 Printed: 08 -11 -2008 CITY OF TUKWIL I Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Plumbing /Gas Permit No. ()g-- Project No. For Dice. rise only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 3ek9 4- I41)o7/�� Tenant Name: Al )■ Uf 1-44W rz._ p Co Assessor's Tax No.: 00 3� Suite Number: Floor: /� �©©��.. New Tenant: .... Yes J ..No Property Owners Name: rt- M4p4 r" gst.l- i> � L `� Mailing Address: c /7 /NP(15r1zy fig, Yv lLA w Ctty State CONTACT PERSON -Who do we contact when your, permit is ready to be issued, Name: M !'t �!`_ Ur) ,V Day Telephone: Mailing Address: 4 �,� G— 6/01/001 /SP-- City State Z' E -Mail Address: %1 S UT/ A4?�r ,76). -s'7 AIt7- Fax Number: ?�jO ,) PLUMBING / GAS PIPING CONTRACTOR INFORMATIO] Company Name: Mailing Address: a o6 L / �— �- S Ni s t J4- 9 2,o ,(� � � (ft") Y'/ City State Zip Contact Person: • Y I Day Telephone: 360 cg.-)O 0/21) E -Mail Address: M S OT-7 IMP e_n r 6 eO/f Fax Number: ,__(oe7 s--63 6 Contractor Registration Number: .PL () Expiration Date: ARCHITECT OF RECORD All plans must be wet stamped by, Architect of Rec'ort Company Name: Mailing Address: / / P%` } ty-_`7 �C ) .-311-7-t- 1,04- q'cgfD City State Zip Contact Person: Day Telephone: .5 —P 7- 7/ zo E -Mail Address: Fax Number: ENGINEER OF RECORD . -'All plans musi e wet stamped by Engineer (-.) Record Company Name: Mailing Address: Contact Person: E -Mail Address: Q:\Applications\Porms- Applications On Line \3 -2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4 -2006 bh City Day Telephone: Fax Number: State Zip Page 1 of 2 Valuation of Project (contractor's bid price): $ Ono Scope of Work (please provide detailed information): Y. ^E c'N V EC1-- t [y r- Building Use (per Int'l Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks / Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment j Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Signature: Print Name: • R AU • • ZED 11 A614-r2g- s U'T 1 Mailing Address: c90<::) A- IE - Date: 3 i Day Telephone: 3& ® / 70 oWaM IS 17L- w, gi8290 City State Zip Date Application Accepted: Date Application Expires: ii s I _(J �y a Staff Initials: /k c Q:\Applications\Fonns- Applications On Line \3 -2006 - Plumbing -Ges Piping Permit Application. doc Revised: 4 -2006 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: httg / /www.ci.tukwila.wa.us Parcel No.: 0223200032 Address: 340 ANDOVER PK E TUKW Suite No: Applicant: MINUTE MAN PRESS RECEIPT Permit Number: PG08 -216 Status: PENDING Applied Date: 07/31/2008 Issue Date: Receipt No.: R08 -02810 Initials: WER User ID: 1655 Payment Amount: $139.00 Payment Date: 07/31/2008 03:23 PM Balance: $0.00 Payee: THE PLUMBERS TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 139.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000/345.830 23.00 000.322.103.00.0 116.00 Total: $139.00 5524 08 /01 0710 TOTAL 139.00 doc: Receiot -06 Printed: 07 -31 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit Project:: /i /� O /7/,-tr7 /* )794w i 'S Type of Inspection: % ./ti.9 / Address: 3 L/) 42 'vdww. ,de Date Called: Special Instructions: .�kk Date Wanted: t6 " /V! °C / p.m. Requester: Phone No: —may -VZ/ 4°- Approved per applicable codes. El Corrections required prior to approval. COMMENTS: -r p r -{ ( p-ie t I the .00 REINSPECTION F E REQ !RED. Prior to inspection, fee must be id at 6300 Southcente Blvd. uite 100. Call to schedule reinspection. R "eipt No.: 'Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 PC 8 -21 Project: . 4 I rv1( -1 G IA Pfe Type of Ins ction: s (Ax lik - tiv C Address: -3 L-► 0 (1,J( (Ne u Date Called: 6,r J U j-.1 1N Jr $c. 9 Special Instructions: Zr Date anted: — 12 - , u1 Ci,.. p.m. Requester: PheCNb 9,-(c)-0/26 0 ` ke —A-rJ VS Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 0 ` ke —A-rJ Di) /1-6s 5-0 °�,' oit / el. J Jr, l 2.,'?., si,)De DA M S- e ,,I,i, 4.. LJs-. p —���el (_ j .l1.i1<< tit LJ& ` Inspecto Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: WORD COPY o PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -216 PROJECT NAME: MINUTE MAN PRESS SITE ADDRESS: 340 ANDOVER PK E X Original Plan Submittal Response to Incomplete Letter # DATE: 07 -31 -08 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: ui ding f) ivision Public Works Fire Prevention n Planning Division Structural ❑ Permit Coordinator ERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08-05-08 Complete Comments: r' Incomplete ❑ Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 09-02 -08 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Untitled Page • 0 General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. PLUMBERS, THE Business and Licensing Information Name PLUMBERS, THE UBI No. 600564790 Phone 3605683880 Status ACTIVE Address 206 AVE G License No. PLUMB * *151JR Suite /Apt. License Type CONSTRUCTION CONTRACTOR City SNOHOMISH Effective Date 4/19/1985 State WA Expiration Date 1/29/2009 Zip 98290 Suspend Date County SNOHOMISH Separation Date Business Type INDIVIDUAL Previous License MECON* *20304 Parent Company Next License Associated License Specialty 1 GENERAL Specialty 2 UNUSED Business Owner Information Name Role Effective Date Expiration Date SUTIN, MARK D OWNER 04/19/1985 Bond Amount Bond Information Page 1 of 3 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 TRAVELERS CAS & SURETY 206085397 02/19/2002 Until Cancelled $12,000.0012/14 /2001 4 RELIANCE SURETY CO 6085397 02/19/1998 Until Cancelled 02/19/2002 $6,000.00 3 RELIANCE SURETY CO 6085397 02/19/199702/19 /1998 $6,000.00 2 TIG SPECIALTY INS CO A1C324907402/19/199202/19/1997 $6,000.00 1 NEW SOUTH INS CO 112359 02/19/198502/19 /1992 $6,000.00 https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= PLUMB ** 151 JR 08/11/2008 REFLECTED CEILING PLAN 0 8' 24' t► 1/8" e 1'— 0" ..Nfjo, ItAN414., Ur 0-1 C. -Co SE ert3.5 litc_trrrog. 1 /ah 443,4 1-141LoVer - Rr rDp POWER & DATA PLAN L— i 0 8' 16' 24' 1/8" = SEPARATE PERMIT REQUIRED FOR: Wptechanical Ki ectrical O Plumbing O Gas Piping City of Tukwila BUILDING DIVISION GENERAL RCP /POWER /DATA NOTES REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE WORKING CONDITION OF ALL EXISTING OUTLETS NOTED TO REMAIN. 3. ALL OUTLETS SHOWN ARE APPROXIMATE. DUE TO HIDDEN CONDITIONS ADDITIONAL P /P /D MAY EXIST BUT NOT BE REFLECTED ON THE PLANS. 4. FURNITURE SHOWN FOR INTENT ONLY, FINAL LOCATION OF FURNITURE AND OUTLETS TO BE COORDINATED WITH TENANTS FURNITURE VENDOR. VERIFY ELECTRICAL AND VOICE /DATA REQUIREMENTS WITH TENANT. 5. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 6. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEILING PLAN DESIGN. 7. LIGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. 8. UNLESS NOTED OTHERWISE, MULTIPLE SWITCH'S IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX AND COVERED WITH A SINGLE COVERPLATE. 9. CLEAN, REPAIR OR REPLACE AS REQUIRED ALL EXISTING SUSPENDED CEILING GRID AND TILES EXISTING TO REMAIN. 10. HVAC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY /RETURN GRILLS PRIOR TO COMPLETION OF PROJECT. 11. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES TO BE RELOCATED. 12. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR PROVIDING CUT SHEETS TO DESIGNER FOR ALL FIXTURES DESIGNATED AS NEW. KEYED SHEET NOTES • RE-ROUTE SWITCHING SO THAT ALL SWITCHES ARE CONTROLLED FROM WITHIN THE SUITES THEY SERVE. • CEILING OUTLET FOR NEON SIGN. VERIFY LOCATION WITH TENANT. 4 CONTRACTOR SHALL DETERMINE IF ELECTRICAL CONDUIT CAN BE PLACED IN WALLS OR PROVIDE OUTLETS IN RIGID CONDUIT. VERIFY WITH BUILDING MANAGEMENT. FINISH NOTES REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submit tI and may include additional plan review fees. i(\ f. V ED FOR CODE COMPLIANCE APPRO`* ; ED rNG - 5 700a Tu ►� Minuteman Press. NITErla trrortlara, Th. ,*.t y Law Imo M Tenant: MINUTEMAN PRESS ANDOVER EXECUTIVE PARK 340 ANDOVER PARK EAST, BUILDING 2, #360 ALSO KNOWN AS 596 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BUILDING 9 617 INDUSTRY DRIVE TUKWILA, WA 98188 Colt burgess design I interiors 0 architecture I97; Firth knout Suitt 400. Sank . WA 114101 10.: 904.4 *7.7190 FAX:904. $*7.7179 All reproduction do intellectual property rights reserved c 2008 l t a M IN 1. VERIFY ALL FINISHES WITH BUILDING MANAGEMENT AND OTHERS. 2. PROVIDE B -1 THROUGHOUT, UON. 3. PROVIDE P -1 THROUGHOUT, UON. 4. PROVIDE CPT -1 THROUGHOUT, UON. 5. REFER TO ELEVATIONS AND DETAIL SHEETS. 6. CENTER TRANSITION BETWEEN MATERIALS UNDER DOOR PER DETAILS. FILE COPY Permit No. Mar review approval is subject to en • rs and omissions. glob Approval of construction documents does nrt41K20seal the violation of any adopted code or • tame. Receipt of approved Fief Co - : is acknowledged: By `j )( 'L` k F.I 1r Date: Tukwi City Q# l if TING DMS N CEILING LEGEND - LIGHTING FINISH SPECIFICATIONS WALL MOUNTED DEVICES LIGHTING SUMMARY SYMBOL DESCRIPTION /SPEC SYMBOL MANUFACTURER DESCRIPTION SYMBOL DESCRIPTION EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN. = NEW NEW EXIT SIGN. COORDINATE FINAL LOCATION WITH CODE OFFICIAL. BASE r :,) ' (' lay EX STING TO REMAIN r 71 IG EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE REMOVED. R R = RELOCATED RELOCATED 2' X 4' FLUORESCENT FIXTURE. 8 -1 FLEXCO 4 "h STRAIGHT RUBBER BASE. COLOR: TBD DUPLEX OUTLET CEILING LEGEND - CONTROLS SYMBOL DESCRIPTION CARPET QUADRAPLEX OUTLET CPT —I PHILADELPHIA FIELD CARPET / 26 OUNCE COLOR: TBD INSTALLED: DIRECT GLUE DUPLEX OUTLET (# DENOTES MOUNTING HT IN INCHES) NEW SWITCH LOCATION. PAINT JUNCTION BOX TWO -WAY SWITCH LOCATION. P -1 TBD GWB EGGSHELL FINISH COLOR: TBD DEDICATED DUPLEX OUTLET EQUIP VENT LIST - VERIFY ALL REQUIREMENTS WITH TENANT PLASTIC LAMINATE VOICE & DATA COMBINATION OUTLET 2 UNDER COUNTER REFRIGERATOR (BY TENANT, C.C. TO PROVIDE COPPER WATER LINE AND HOOK UP ICE MAKER AS REQ'D) MICROWAVE (BY TENANT) PL -1 TBD PLASTIC LAMINATE HORIZONTAL SURFACES /BACKSPASH. LAMINATE COLOR: TBD BLANK COVER PLATE PL-2 TBD PLASTIC LAMINATE VERTICAL SURFACES LAMINATE COLOR: TBD INTERIOR MELAMINE: TBD MISC. NOTATION N DENOTES A NEW DEVICE 2004 Washington State Nonresidential Energy Code Compliance Form Lighting Summary LTG —SUM 2004 Project Info Project Address: MINUTEMAN PRESS Date 04/15/08 340 ANDOVER PARK EAST For Building Department Use TUKWILA, WA 98188 Applicant Marne: BURGESS DESIGN INC. Applicant Address: 1326 FIFTH AVENUE, 1500, SEATTLE, WA 98101 Applicant Phone: 206 587 7120 Project Description ❑ New Building 0 Addition 110 Alteration Compliance Option ❑ Prescriptive w Lighting Power Nlowonce ❑ Systems Analysis (Sae Nolificatfon Checklist (over). Indicate Prescriptive As LPA spaces clearly on plans.) 0 Ho changes are being made to the lighting ® Less than 60% of the fixtures are new and installed lighting wattage is not being increased ?Goa 21e RECEIVED JUL 312000 PERMIT CENTER No. Issue Description Date REVIEW SET 4/15/08 Drawn by: PN Reviewed by: KK Project No: 08-3403-00 POWER & DATA / FINISH REFLECTED CEILING PLANS Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.2B.1 3 PL -1 P —LAM COUNTERTOP BACKSPLASH ADA COMPLIANT SINK & FAUCET EE) EQ. EQ. EQ. UNDER COUNTER REFRIGERATOR BY TENANT BREAK AREA ELEVATION PL -2 P —LAM LOWER CABINETS AND DRAWER WITH ONE ADJUSTABLE SHELF 81 3/8" = 1'— 0" 3/8" ff 3/8" = 1'— 0" Ce( 9 3/8" = 1'— 0" 3/8" = (G) 3/8" = 3/8" = 1'_ 3/8" = 1'— 0" 3/8" = 1,_ 0" EVIbWWW FORR i, CODE COMPLIANCE APPROVED AUG - 5 2000 i BUILDING DIVISION 3/8" _ 1, 0" PG00w2.1e RECEIVED JUL 3 1 2008 PERMIT CENTEF. @? PiVSS.*TErnaM �1r, .. tt Or Minuteman Tenant: MINUTEMAN PRESS ANDOVER EXECUTIVE PARK 340 ANDOVER PARK EAST, BUILDING 2, #360 ALSO KNOWN AS 596 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BUILDING 9 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design I Interiors Q architecture 172! Fifth Amu! SuItt 109. Swlde . WA 10101 IEkf 201417.7M FAX104. 5$7.7171 All reproduction & intellectual property rights reserved c 2908 Professional seal No Issue Description Dote REVIEW SET 4/15/08 Drawn by: PN Reviewed by: KK Project No: 08- 3403 -00 INTERIOR ELEVATIONS Original drawing is 24" x 36 ". scale entities accordingly if reduced A.6.1 PAPER CORNER REINFORCEMENT, TIP, ACOUSTIC INSULATION AS REQUIRED METAL STUDS 5/8" GYP. BOARD A -PARTITION INTERSECTION DETAIL DEVICES SHOWN STACKED IN PLAN ARE TO ALIGN VERT. AS SHOWN BELOW DOOR SCHEDULE AT LOCATION AS DIMENSIONED ON PLAN; OR NEXT TO DOOR / OPENING AS DIMENSIONED BELOW ci I 6j, FIRE ALARM STROBE FRAME WHERE OCCURS ROOM SIGNAGE, ETC. THERMOSTAT BOTTOM OF FINISHED CEILING LIGHT & PROJECTION SCREEN SWITCHES, WALL MOUNTED OCCUPANCY SENSOR CARD READER WHERE OCCURS HARDWARE LATCH FINISHED FLOOR TELEPHONE OUTLET ELECTRICAL OUTLET 1. LOCATED SWITCHPLATES, ELECTRICAL AND TELEPHONE WALL OUTLETS AT NEAREST STUD FROM SCALED LOCATION ON PLAN, UNLESS SPECIFICALLY DIMENSIONED ON PLAN, ELEVATION, OR LOCATION AS PER DIAGRAM ABOVE. 2. CENTER FIRE ALARM STROBES DIRECTLY ABOVE FIRE EXTINGUISHER CABINETS WHERE BOTH OCCUR. 411 8" 12" 3" = 11_0" 2' -1" LINE OF CEILING PROVIDE 4" BACKSPLASH AS INDICATED ON ELEV. SCRIBE TO WALL CONTERTOP W /PLASTIC LAMINATE PER FINISH 17 j SCHEDULE r 6" MAX, / PROVIDE SOLID PANEL PROVIDE SINK WHERE INDICATED — REFER TO PLUMBING DWGS PROVIDE ADA COMPLIANT SINK (Sc FAUCET. PROVIDE CLEARANCES. PLUMBING BOOT AS REQ'D BASE AS PER SCHEDULE. TURN INSIDE 0 CABINET OPENING, TYP. FINISH FLOOR LINE. RUN TO REAR OF CABINET OPENING. LINE OF CABINET (BEYOND) TYP. ADA SINK SECTION l 11 12" 1 -1/2" = Q GENERAL DEVICE ALIGNMENT 12" / /, BOTTOM OF STRUCTURE 1 PROVIDE ENCAPSULATED ACOUSTICAL BATT EXTENDING 24" EACH SIDE OF PARTITION. 2 "X2 "X12" MIN. LEG AT STRUCTURE — ATTACH W/2 POWDER DRIVEN FASTENERS PER BRACE OR OTHER APPROVED METHOD 0" PLENUM HEIGHT OF 5' -0" OR LESS 2 1/2 "x25 GA METAL STUD BRACING 0 8' -0" OC TO STRUCTURE DIRECTION ALTERNATE. PARTITIONS PERPENDICULAR TO PARTITION ACT AS BRACE PLENUM OF 5-0" TO 10' -0" SHALL USE NESTED OR BACK TO BACK 3 -1/2" 25 GA. STEEL STUDS. ABOVE 10' -0" OR PLENUM. CONTACT ARCHITECT FOR ADDITIONAL INFORMATION. MAX PARTITION WEIGHT 151bs. /P.S.F. SUSPENDED CEILING AS SCHEDULED VERIFY B/S HEAD CONDITION 3/8" CONT. FOAM SOUND ISOLATION TAPE TAPEABLE MET. TOP TRACK ATTACHED TO BRACING W/2 SELF — TAPPING SM. SCREWS 0 48 "oc, AND 3/4" PIPE SLEEVES INSULATION 2 1/2" X 25 GA METAL STUDS 0 24" OC, TO 10' -9" MAX. HEIGHT. 1 LAYER 5/8" TYPE "X" GYP. BD. EA. SIDE OF METAL STUDS POWER DRIVEN FASTENER 0 24" OC MET. RUNNER TRACK SEALANT CONCRETE SLAB 3 STUDS NOTE: COORDINATE ANCHOR BRACKET LOCATIONS W/ CASEWORK & EQUIPMENT WHERE SCHEDULED, AND MANUF. MOUNTING INSTRUCTIONS C' MIN, ANCHOR BRACKET: 6"Xl6ga UNPUNCHED STUD TRACK, ATTACH TO 3 STUDS MIN FINISHED FLOOR TYPICAL ANCHOR BRACKET FRAMING LI 0 12" 105 3' -0" 7' -0" WD DOOR 8c HARDWARE GENERAL NOTES 1. SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION. 2. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME HEAD. REFER TO SPECIFICATIONS FOR CLEARANCES. 3. DOUBLE DOOR NOMINAL WIDTH INDICATES 2 DOOR LEAVES OF EQUAL WIDTH, U.O.N. 4. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH — BOLTS. 5. DOOR / HARDWARE SHALL COMPLY WITH ALL APPLICABLE IBC & ACCESSIBILITY REQUIREMENTS. HARDWARE GROUP 3„ = 1, -0„ PROVIDE MIN 25 GA STUDS & ANCHOR BRACKET ANCHORAGES. DOUBLE STUDS 0 END OF PARTITIONS. 3—#8 PAN HEAD SHT. MTL. SCREWS 6 "x16 GA UNPUNCHED STUD TRACK WITH FLANGES COPED AT VERTICAL STUDS. ATTACH TO TWO STUDS MIN. & EXTEND 6 "MIN BEYOND MOUNTING POINT EACH DIRECTION. NOTES: 1. TYPICAL ANCHOR BRACKET ASSEMBLY FOR HANDRAILS, GRAB BARS & TOILET ACCESSORY ANCHORAGES. 2. COORDINATE ANCHOR BRACKET LOCATION WITH ACCESSORY MANUFACURER MOUNTING INSTRUCTIONS. ACT SEISMIC BRACING DIAGRAM HARDWARE GROUP HARDWARE REMARKS GROUP E EXISTING HARDWARE GROUP 1 SINGLE, PASSAGE LATCHSET NON —RATED GROUP 2 SINGLE, OFFICE LOCKSET NON —RATED 1 PASSAGE LATCHSET (1-1/2) PAIR HINGES 1 WALL — MOUNTED DOOR STOP DOOR TYPES L_ ou 12 GA. BRACING WIRE WITH MINIMUM 4 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE—TYP. 12 GA. VERTICAL HANGER WIRE AT 4'—O" EACH WAY WITH MINIMUM 3 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE NTS 1 OFFICE FUNCTION LOCKSET (1 -1/2) PAIR HINGES 1 WALL — MOUNTED DOOR STOP FRAME MATERIAL & FRAME FINISH TO MATCH SUITE STANDARD FLUSH S.C. WOOD DOOR — DOOR FINISH TO MATCH SUITE STANDARD E = EXISTING, MATCH ALL EXISTING CONDITIONS RIENI le ED FOR \ cope COMPLIANC APP °VW BUG - ' N City Of Tuk ila BUILDING 01:01.011 SIDELIGHT /GLAZING SCHEDULE SIDELIGHT SEISMIC COMPRESSION STRUT I- X C7 w w w 1— ww 4" 36" 7' —O" 7' -0" 3' -0" 3' -0" A B 1/4" TEMPERED 1/4" TEMPERED M.E. M.E. SIDELIGHT /GLAZING TYPES CROSS RUNNER MAIN RUNNER DISTANCE FROM BRACING WIRES TO CROSS RUNNERS NOTE: PROVIDE ACT SUSPENSION GRID TO COMPLY WITH IBC SECTION 1621 MINIMUM STANDARD PER SECTION 9.6 ASCE7. VERIFY REQUIREMENTS WITH CITY OFFICIALS NON -RATED FLOOR TO CEILING PARTITION FACT SEISMIC BRACING L1 1-0" 1 11 12" DIAGRAM NTS A FRAME & FINISH TO MATCH SUITE STANDARD GLAZING AS SCHEDULED 1-- w E = EXISTING, MATCH ALL EXISTING CONDITIONS WIDTH B V7Minuteman Press. RNA 17. Fri* a Lotr a *. ship in Nine Tenant: MINUTEMAN PRESS ANDOVER EXECUTIVE PARK 340 ANDOVER PARK EAST, BUILDING 2, #360 ALSO KNOWN AS 596 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BUILDING 9 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design 'interiors 4) architecture 172 iirlh Area,le Sur1e FQq . 5er1Ut . WA 11101 1(l: 701.$17.7121) FAx:la1. 117,7177 All reproduction & intellectual property rights reserved c 2008 Professional seal No. Issue Description Date REVIEW SET 4/15/08 Drown by: PN Reviewed by: KK Project No: 08- 3403 -00 DOOR SCHEDULE / SIDELIGHT SCHEDULE / DETAILS Original drawing is 24" x 36 Scale entities accordingly 4 reduced RECE JUL 3. 2006 PERU:- DENTE° ?Gofr uo A.9.1