Loading...
HomeMy WebLinkAboutPermit PG08-225 - DOUBLETREE SUITESDOUBLETREE SUITES 16500 SOUTHCENTER PY PGO8-225 Parcel No.: 6437300020 Address: Suite No: CityIllf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 16500 SOUTHCENTER PY TUKW Permit Number: Issue Date: Permit Expires On: PG08 -225 01/06/2009 07/05/2009 Tenant: Name: DOUBLETREE SUITES Address: 16500 SOUTHCENTER PY , TUKWILA WA Owner: Name: CHA SOUTHCENTER LLC Address: 16500 SOUTHCENTER PKWY , SEATTLE WA Contact Person: Name: DAN MYERS Address: 911 WESTERN AV, STE 301 , SEATTLE WA Contractor: Name: WESTERN MECHANICAL SYSTEMS INC Address: 1911 SW CAMPUS DR #321 , FEDERAL WAY WA Contractor License No: WESTEMS921BG Phone: Phone: 206 515 -4004 Phone: 206 571 -3810 Expiration Date: 01/07/2010 DESCRIPTION OF WORK: PROVIDE APPROXIMATELY 30 FT OF 1 1/4" GAS PIPING TO A NEW 399 MBM BOILER LOCATED IN AN EXISTING MECHANICAL ROM (#141). Value of Plumbing /Gas Piping: Fees Collected: $2,500.00 $115.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 1 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -225 Printed: 01 -06 -2009 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PGO8 -225 Issue Date: 01/06/2009 Permit Expires On: 07/05/2009 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied ami 'th, Date: k(ii, ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: Print Name: 1-14 CL .14-0)-L Date: � �D This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -225 Printed: 01 -06 -2009 Parcel No.: 6437300020 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16500 SOUTHCENTER PY TURIN DOUBLETREE SUITES PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -225 ISSUED 08/12/2008 01/06/2009 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or arty other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -225 Printed: 01 -06 -2009 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: iq V Date: doc: Cond -10/06 PG08 -225 Printed: 01 -06 -2009 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Irll]r uir�r.ci.ttr��rilu.uu.��s Sl'1'1+: LOCATION: Building.Permtt No. Mechanical Permit No . Plumbing/Gas Permit No Pubhc:Works Permit No., Project NO.:. (For _oj e: rse,o ir) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: /LS?° <7tAtilCefifer z 6Jy GbtilWree Su: tec Property Owners Name: cHA 6a {CC:Arre-R Mailing Address: /k<DO SDs1lj Prkyap�/ Tenant Name: King Co Assessor's Tax No.:bilt3�OtV2000 Suite Number: Floor: New Tenant: ❑ Yes C.. No City LiA State Zip CONTACT PERSON wrho;do we contact when your petmiiis,ready to be-issued:. Name: Ciu4 h'IYP Mailing Address: G} l ( Werstervt Ave_ Suyf-P 30 E -Mail Address: aka K;eb,A ® 't n . Csmn Day Telephone: 20 b - S' /J - 401) 4 Seccr -f-1 e- City state Fax Number: 206 " 5I3 24t2, Zip G:E iERA .CONTRACTOR INEOI A' (Conttaetur Informat�#tt 1or'Aiechari��al,(pg; )ior 1?'l b> g and Gas Piping (pg 5)) Company Name: r1'ane- Mailing Address: ?°21 l5-2 -0 (. A Contact Person: ude,.° f 3 ?Yce- E -Mail Address: p (ct Ati . j0yee ® .erAVte • cor" Contractor Registration Number: City State Zip Day Telephone: 42• - set, - (66 eP Fax Number: Expiration Date: CIUTECT OF RECOIWI3 Gplaas Hirst be wet stamped try Architect of Record. `. Company Name: /U /A Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State \ Zip ENGINE It d RECORD I.rns bs mast be met stamped Eng nett of 12eeord' Company Name: (Y11,434+6 X 3-1 earl Y1 a. Mailing Address: OM f W9 & II / -fe 30 Contact Person: Do,„ yer5 E -Mail Address: Aeoltell,4 go Inv ena _ Gc m QMpplications\Fomie- Applications On Line - Permit Apphcation.doc Revised: 9 -2006 bh Sec- t-{-Ie_ g110Y- City State Zip Day Telephone: 6 • gig - 400 L - Fax Number: 7.2 .. (s - 7 D z� Page 1 of 6 M E CHANICAL PERMIT INFORMATION -- 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: tAlsgCtern MeCJANI.1 C 0.� �(S1 & 5 R C Mailing Address: IQ (( S) Case4f uc Moe, 4 314 feral opty �w , _I City Contact Person: !" �I w'et ($ E -Mail Address: Contractor Registration N r: W>Q 9,O2-3 state Zip Day Telephone: 2,5- 3 - 9 • 9S-44- Fax Number: Expiration Date: Valuation of Mechanical work (co Scope of Work (please provide detailed e (O h tv 6✓J ZO t tvt if Ivetoalet5 7 t+^ v»e 349 149 IJse: Residential: New .... ❑ Replacem Commercial: New ❑ Replacement . ovt E' L 'ter' c L.111 to tom'- C ra.. Ike; or. EX7 1.1 ec Mewl Fuel Type: Electric 1-1 Gas .... E . Other: Indicate type of mechanical work being installed and the . tity belo Unit Type: Qty VnitType :. . Qn Urti:- .ype; .Qt : 'Boiler /Compressor: Qty Furnace<I00K BTU Air Handling Uni 0.000 CFM Fire 1 \■ per 0-3 HP /100,000 BTU Furnace • 100K BTU Evaporator C . er Diffuser '. 3 -15 HP' 5[10,000 BTU Floor Furnace Ventilation Connected to Single ' uct Thermostat''\ 15 -30 HR 1.000,000 BTU Suspended/Wall /Floor Mounted Heater Ventil: .. System Wood/Gas Sto �-, 30-50 HP/1,750,000 BTU Appliance Vent H., : and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System 1 ncinerator - Domestic Other Mechanical Equipment Air Handling Unit .10.000 CFM Incinerator - Comm/Ind Q: Appfications\Fonns•Apptic [ions On L ne13.2006. Permit Appficat on.doc Revised: 9 -2006 bh Page 4 of 6 241? PLUME]ENG AND GAS PIPING PERMIT LNFORMATION -7206-431-M70 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: SQWie Mailing Address: AS MeeiAwn:f t-nac er Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip Valuation of Plumbing work (contractor's bid price): $ /V /A Valuation of Gas Piping work (contractor's bid price): $ 2,51-'12 • °° Scope of Work (please provide detailed information): /�}� tsi Op9Ir'Ox1Wt0.' 3o-�{ 4 l.. 14:1 &As tirwig- "�° � K 39g l�'tti7' 1 witar , co. 14 a,tti iiist�n- Hec4colicri vvO•• C* ICI ) Building Use (per Intl Building Code): R.-te \ Occupancy (per Intl Building Code): ( Dtnr 12- 1 Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type : :: Qh F44ili0' pe; :. Qtr- - V'rsture Tape. Q ' :`: )1+ftstur+e:T:ipe: Qty- Bathtub or combination bath. shower Drinking fountain or neater cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder. commercial Receptor. indirect waste Clothes washer. domestic Floor drain Sinks Dental unit. cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building serer or trailer park sewer Rain water system — per drain (inside budding) Water heater and or vent Additional medical gas inlets outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent. except for kitchen type grease interceptors Repair or alteration of water piping and or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas Q:l4pplicaeons\Fonne-Applicationa On L neln -2006 - Permit Applicatioadoc Revised: 9 -2006 bh Page 5 of 6 • • PERMIT APPLICATION NOTES - Applicable to all permits; in Ibis application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 1053.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OR AU HORIZED AGENT: Signature: Date: Cf / /2J0, Print Name: Mailing Address: 9/1 Warier/ ti Ave t&tife- 30 Date Application Accepted: Day Telephone: �6 16.° / 6 by 1 sfle City L,pt 9C,10 t� State Zip Date Application Expires: Staff Initials: Q: Wpphcstions\Forms- Appliwrtone On LmeU -2006 - Permit Appbarnon.doc Revised 9 -2006 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6437300020 Permit Number: PG08 -225 Address: 16500 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 08/12/2008 Applicant: DOUBLETREE SUITES Issue Date: Receipt No.: R08 -02915 Payment Amount: $115.00 Initials: JEM Payment Date: 08/12/2008 03:21 PM User ID: 1165 Balance: $0.00 Payee: INVENTRIX ENGINEERING, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1991 115.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES PLAN CHECK - NONRES 000.322.103.00.0 92.00 000/345.830 23.00 Total: $115.00 6015 08/12 9710 TOTAL 115.00 doc: Receiot -06 Printed: 08-12 -2008 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION k 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 P661 -225 Project: Type of Inspection: , A dress: In CO 0 SC p >iv k /rl- J c Date Called: As v A (9 Date Wanted: 1 -((o - dq p.m. Special Instructions: % L � DD.(ef (1 ti,(.�e ] n D (' A'S I + X41 S6C.9'; G T Requester: Phone, (6 — Scif '' / ! r� I r� 1 Approved per applicable codes. ElCorrections required prior to approval. ' COMMENTS: pP f- Itit :7"--1--.) J c t tJA Date: r -0y ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: •,o INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ' - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Probe Type of Inspectipn: Address: /o15 06 //7S .14-*/ P' Date Called: Special Instructions: Date Wanted: Requester: Phone No: .226 -..L-5-q--54/7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: �t /a-t-PeA .c'et:? gYc��' —1 — D= 7-6? �x.00 REINSPECTION FEE ' QUIRED /Prior to inspection, fee must be » id at 6300 Southcenter Blv , Suite 00. Call to schedule reinspection. ceipt No.: / ,Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit (47W -22S¢ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proj t: Type of 1 ection: Address: / 6._.-69.0 _Sd>i /Aeta; i / Date Called: bate Special Instructions: -s Wanted: / 7 -0 "' Requester: " ,k -- Rd, /pfr- /3 roil Phone No /: _ !/.j 0Approved per applicable codes. Corrections required prior to approval. 9MNENTS: I t -- /1,4 -- 6,6 c /K`/ ,/ /� Vail f ,tJ ---4144- L &As i- „tc, /)/f3-9(44, AJFfd# ,k -- Rd, /pfr- /3 roil -X044 !/.j 0 /id/ Rcrf 14-Affs55 G1Ji )e' 5cut :4- 1 C C Inspector: Da e: $•0. +0 REINSPECTION F REQUIRED Prior to inspection, fee must be d at 6300 Southcenter Blvd., Suite 00. Call to schedule reinspection. Reeipt No.: Date: 01 -02 -2009 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director DAN MYERS 911 WESTERN AV, STE 301 SEATTLE WA 98104 RE: Permit Application No. PG08 -225 16500 SOUTHCENTER PY TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 08/12/2008 , has not been issued by the City of Tukwila Permit Center. Per the Uniform Plumbing Code and/or International Fuel Gas Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 02/08/2009 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 02/08/2009. If it is determined that an extension is granted, your application will be extended one time only, for an additional 180 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall Technician xc: Permit File No. PGO8 -225 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -225 DATE: 08 -12 -08 PROJECT NAME: DOUBLETREE SUITES SITE ADDRESS: 16500 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEP TMENTS�I Bui din Division Public Works ❑ Fire Prevention Structural Planning Division nPermit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 08-14-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: APPROVALS CDR CORRECTIONS: Approved V Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 09-11-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Untitled Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with L£tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County WESTERN MECHANICAL SYSTEMS INC 2065713810 1911 SW CAMPUS DR #321 FEDERAL WAY WA 98023 KING Business Type CORPORATION Parent Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602783205 ACTIVE WESTEMS921 BG CONSTRUCTION CONTRACTOR 1/7/2008 1/7/2010 KDMECI *008CJ PATRIGI927BN PLUMBING UNUSED Business Owner Information Name Role Effective Date Expiration Date KACSO, OTTO PRESIDENT 01/07/2008 Bond Amount KACSO, TRACI VICE PRESIDENT 01/07/2008 70423303 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 WESTERN SURETY CO 70423303 12/11/2007 Until Cancelled $6,000.00 01/07/2008 Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date CATLIN https: // fortress .wa.gov /lni/bbip/Detai1.aspx ?License= WESTEMS921 BG 01/06/2009 327.74' 350,0' 600.03' 502.3' SOUTHCENTER PARKWAY DOUBLE TREE HOTEL L 561.0' REVIEWED FOR CODE COMPLIANCE A PPROVED A UG 2 0 200 C iry " ukwila BUILDTN,�DP/!�I AUG 2 0 200 City 0 ukwila BUILDIKDIVISIQN REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. PROJECT INFORMATION ADDRESS: 16500 SOUTHCENTER PARKWAY, TUKWILA WA 98188 PARCEL NUMBER: 6437300020 OWNER: DOUBLE TREE HOTEL PROJECT MANAGER: TRANE (MICHAEL JOYCE) CONTACT: 425 -5&S -1668 EMAIL: MICHAELJOYCEC©TRANE.COM MECHANICAL ENGINEER: INVENTRIX ENGINEERING (DAN MYERS) CONTACT: 206 -515 -4004 EMAIL DANIELM @INVENG.COM PROJECT DESCRIPTION: 1. SCOPE OF ARCHITECTURAL WORK: NONE(NO BUILDING MODIFICATIONS) 2. SCOPE OF STRUCTURAL WORK: NONE(NO STRUCTURAL MODIFICATIONS) ALL NEW EQUIPMENT TO BE INSTAI1FD ON THE GROUND LEVEL 3. SCOPE OF CIVIL WORK: NONE(NO MODIFICATIONS TO EXISTING UNDERGROUND UTILITIES). 4. SCOPE OF MECHANICAL WORK: A. REPLACE TWO EXISTING 60 TON CHILLERS AND TWO CONSTANT SPEED CHILLED WATER CIRCULATION PUMPS WITH ONE 176 TON CENTRIFUGAL LIQUID G: •.LLER AND TWO VARIABLE SPEED CHILLED WATER CIRCULATION PUMPS TO IMPROVE THE EFFICIENCY OF THE CHILLER SYSTEM. B. REPLACE TWO EXISTING 40KW ELECTRIC UNIT HEATERS WITH A HYDRONIC PREHEAT SYSTEM. THE NEW HYDRONIC PREHEAT SYSTEM CONSISTS OF ONE 399MBH GAS -FIRED BOILERS, ONE IN -LINE HEATING WATER Fr-CIRCULATION PUMP AND ONE HEATING WATER COIL. 5. REPLACE ALL EXISTING EQUIPMENT CONTROL DEVICES FOR THE ITEMS ABOVE WITH NEW DIRECT DIGITAL CONTROL SYSTEMS TO IMPROVE THE ENERGY EFFICIENCY FILE COPY Permit No. T� 2 Pear review approval is erect to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and melons Is acknowledged: BY Date. �L City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: 1 Mechanical Electrical Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUU 1 2 2008 PERMIT CENTER PERMIT SET z CO CrZ C v Lj CO LCD Cci CO Cr/ o c�z CD ea cd v C cn CIS c � Date: Job No.: Drawn By: Checked by: Filename: Revisions: 08/12/08 822.00 DKM JKS COVER SHEET G0.1 SHEET 1 OF 6 LEGENDS GENERAL LINEWEIGHT LEGEND EXISTING TO REMAIN NEW WORK DEMOLITION FUTURE WORK GENERAL PLUMBING /PIPING LEGEND FIRE PROTECTION LEGEND F DSP FDC FUEL LEGEND FOS FOR GE DF LP FV HYDRONICS LEGEND CWS CWR PCWS PCWR SOWS SCWR TOWS TCWR HWS HWR PHWS PHWR SHWS SHWR PC > CD CDS CDR INDUSTRIAL LEGEND A ACT TM ARG H HE DIRECTION OF FLOW FIRE DRY STAND PIPE FIRE DEPARTMENT CONNECTION PIPE FUEL OIL SUPPLY FUEL OIL RETURN GASOLINE FUEL DIESEL FUEL PROPANE FUEL VENT CHILLED WATER SUPPLY CHILLED WATER RETURN PRIMARY CHILLED WATER SUPPLY PRIMARY CHILLED WATER RETURN SECONDARY CHILLED WATER SUPPLY SECONDARY CHILLED WATER RETURN TERTIARY CHILLED WATER SUPPLY TERTIARY CHILLED WATER RETURN HEATING WATER SUPPLY HEATING WATER RETURN PRIMARY HEATING WATER SUPPLY PRIMARY HEATING WATER RETURN SECONDARY HEATING WATER SUPPLY SECONDARY HEATING WATER RETURN PUMPED CONDENSATE CONDENSATE DRAIN CONDENSER WATER SUPPLY CONDENSER WATER RETURN AIR ACETYLN TRI -MIX ARGON HYDROGEN HELIUM LAB /MEDICAL LEGEND DW DI MA 02 CO2 N2 N20 VAC RO PLUMBING LEGEND IW ODL RDL SD SAN G SCW SHW DW ('F) LSP GW AR AR KCWS KCWR REFRIGERANT LEGEND RS RR STEAM LEGEND HPS HPC MPS MPC LPS LPC STM DISTILLED WATER DEIONIZED WATER MEDICAL AIR OXYGEN CARBON DIOXIDE NITROGEN NITROUS OXIDE VACUUM REVERSE OSMOSIS DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC RECIRCULATED WATER VENT (ABOVE FLOOR) VENT (BELOW FLOOR) WASTE (ABOVE FLOOR) WASTE (BELOW FLOOR) INDIRECT WASTE (ABOVE FLOOR) OVERFLOW DRAIN UNE ROOF DRAIN LINE STORM DRAIN SANITARY SEWER NATURAL GAS (7" WC, UNLESS OTHERWISE NOTED) SOFT COLD WATER SOFT HOT WATER DEIONIZED WATER TEMPERED WATER AT T SHOWN LANDSCAPE SPRINKLER SUPPLY GREASE WASTE ACID RESISTANT WASTE ACID RESISTANT VENT KITCHEN CHILLED WATER SUPPLY KITCHEN CHILLED WATER RETURN REFRIGERANT PIPING SUPPLY REFRIGERANT PIPING RETURN HIGH PRESSURE STEAM HIGH PRESSURE STEAM CONDENSATE MEDIUM PRESSURE STEAM MEDIUM PRESSURE STEAM CONDENSATE LOW PRESSURE STEAM LOW PRESSURE STEAM CONDENSATE STEAM NOTE: SYMBOLS AND ABBREVIATIONS ON THE DRAWINGS SHALL BE INTERPRETED IN ACCORDANCE WITH THE LEGENDS WHEREVER APPLICABLE. NOT ALL SYMBOLS AND ABBREVIATIONS IN THE LEGENDS ARE NECESSARILY USED FOR THE PROJECT. ABBREVIATIONS GENERAL ABBREVIATIONS AFF AEG CI CFM CIRC CLG CP DIV DWG FPM FT GA IN MAX MFR MIN MNT NC ABOVE FINISH FLOOR ABOVE FINISH GRADE CAST IRON CUBIC FEET PER MINUTE CIRCULATION CEILING CHROME PLATED DIVISION DRAWING FEET PER MINUTE FEET GAUGE INCHES MAXIMUM MANUFACTURER MINIMUM MOUNT(ED) NORMALLY CLOSED GENERAL PLUMBING /PIPING ABBREVIATIONS CO CLEAN -OUT COIW COTE COTG FPWH GPM GTV CLEAN -OUT IN WALL CLEAN -OUT TO FLOOR CLEAN -OUT TO GRADE FREEZE PROOF WALL HYDRANT GALLONS PER MINUTE GAS TANK VENT GENERAL HVAC ABBREVIATIONS EXH EXHAUST AIR RA RETURN AIR ANNOTATIONS HYDRONICS ANNOTATION B -# BOILER NUMBER (BLR -1) PLUMBING ANNOTATION PLUMBING FIXTURE ITEM NUMBER P1) # "FD -# FLOOR DRAIN SIZE AND TYPE (2 "FD -1) REFRIGERANT ANNOTATION CU -# CONDENSER UNIT NUMBER (CU -1) STEAM ANNOTATION B -# BOILER NUMBER (BLR -1) HVAC ANNOTATION AH -# AIR HANDLING UNIT NUMBER (AH -1) AT -# ATTENUATOR NUMBER (AT -1) EF -# EXHAUST FAN NUMBER (EF -1) FH -# FUME HOOD NUMBER (FH -1) HR -# HEAT RECOVERY UNIT NUMBER (HR -1) L -# LOUVER NUMBER (L -1) SYMBOLS - CONT. HVAC SYMBOLS INTERNAL INSULATION ALUMINUM /STAINLESS STEEL DUCTWORK (AS SPECIFIED) FLEXIBLE DUCT FLEXIBLE CONNECTION UP (OR DOWN) 1f DUCT OFFSET & DIRECTION TURNING VANES AIR SPLIT TAKEOFF VOLUME DAMPER STEAM SYMBOLS -lit- TRAP SET (AS SPECIFIED) # INDICATES TRAP TYPE NO OBVD OSA PSI PSF SP SS TYP VEL W/ W /IN W/0 WC 0 IE IW PRV RPBP SV SUMP VENT VTR VENT THRU ROOF SA RC -# RF -# SF -# TU -# UH -# NORMALLY OPEN OPPOSED BLADE VOLUME DAMPER OUTSIDE AIR POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT STATIC PRESSURE STAINLESS STEEL TYPICAL VELOCITY WITH WITHIN WITHOUT WATER COLUMN DIAMETER FLAT OVAL EXISTING INVERT ELEVATION INDIRECT WASTE PRESSURE REDUCING VALVE REDUCED PRESSURE BACKFLOW PREVENTER SUPPLY AIR ET -# EXPANSION TANK NUMBER (ET -1) # "FS -# FLOOR SINK SIZE AND TYPE (2 "FS -1) # "RD -# ROOF DRAIN SIZE AND TYPE (2 "RD -1) ROOF COWL NUMBER (RC -1) RETURN FAN NUMBER (RF -1) SUPPLY FAN NUMBER (SF -1) AIR TERMINAL UNIT (TU -1) UNIT HEATER NUMBER (UH -1) SIDEWALL DIFFUSER LOUVER 12 "x8" IL RECT. DUCT SIZE (WIDTHxDEPTH) CIRCULAR DUCT DIAMETER 24 "x18 "0 OVAL DUCT SIZE (WIDTHxDEPTH) /(M DAMPER MOTOR OPERATOR DUCT SECURITY GRILLE FIRE, SMOKE OR FIRE /SMOKE DAMPER SYMBOLS GENERAL SYMBOLS #Q KEY NOTE GENERAL PLUMBING /PIPING SYMBOLS I0 ICH Db 111 E DETAIL NUMBER DETAIL REFERENCE SHEET NUMBER THIS SHEET # MATCH LINE REFERENCE - '` - '-- MATCHED SHEET # FIRE PROTECTION SYMBOLS cC FIRE DEPARTMENT CONNECTION (PEDESTAL) 4 FIRE HYDRANT POST INDICATOR VALVE 0+++ FIRE HOSE RACK FIRE HOSE CABINET HYDRONICS SYMBOLS A STRAINER PRESSURE SWITCH TWO -WAY CONTROL VAVLE PLUMBING SYMBOLS ELBOW UP ELBOW DOWN TEE UP TEE DOWN CONCENTRIC REDUCER /INCREASER ECCENTRIC REDUCER /INCREASER UNION RISE /DROP IN PIPE PIPE SLEEVE EXPANSION JOINT FLEXIBLE CONNECTION PIPE ANCHOR PIPE GUIDE CAP THERMOMETER FLOOR /WALL PENETRATION FLOW SWITCH AUTOMATIC BALL DRIP THRUST RESTRAINT THREE -WAY MODULATING CONTROL VALVE GAS VALVE O ROOF DRAIN 11 CLEAN -OUT (BELOW) �o CLEAN -OUT (FLUSH TO FLOOR OR GRADE) © MANHOLE /DRYWELL Q FLOOR DRAIN HVAC SYMBOLS 4 N NEW DUCTWORK EXISTING DUCTWORK DUCTWORK TO BE REMOVED RECT. SUPPLY DUCT (SECTION) RECT. RETURN DUCT (SECTION) RECT. EXHAUST DUCT (SECTION) ROUND SUPPLY DUCT (SECTION) ROUND RETURN DUCT (SECTION) ROUND EXHAUST DUCT (SECTION) #" CONNECTION TO EXISTING ( #" INDICATES EXISTING SIZE) SECTION NUMBER SECTION REFERENCE —SHEET NUMBER chi tAs 0 v 4 Ib D 0c' CIRCULATING PUMP (POINTS IN DIRECTION OF FLOW) PRESSURE GAUGE VALVE (AS INDICATED OR SPECIFIED) BALL VALVE GLOBE VALVE VALVE IN RISER ANGLE VALVE CHECK VALVE PRESSURE & TEMPERATURE RELIEF VALVE PRESSURE REDUCING VALVE (POINTS TOWARDS LOW PRESSURE) SOLENOID VALVE VALVE W/TAMPER SWITCH HOSE BIBB /WALL HYDRANT HOSE BIBB (ELEVATION) CIRCUIT SETTER SERRATED COCK SPRINKLER HEAD (UPRIGHT) SPRINKLER HEAD (PENDANT) SPRINKLER HEAD (WET SIDE WALL) SPRINKLER HEAD (DRY SIDE WALL) GAUGE COCK SIGHT GLASS AUTOMATIC AIR VENT MANUAL AIR VENT VENTURI AIR SEPARATOR CONDENSATE TRAP FLOOR SINK WATER HAMMER ARRESTER VENT THRU ROOF DOWNSPOUT NOZZLE SANITARY CROSS SANITARY TEE WYE 0 THERMOSTAT DIFFUSER SIZE DIFFUSER TYPE 10x102 DIFFUSER OR REGISTER /GRILLE 250 INFORMATION CFM VALUE RECTANGULAR DIFFUSER CM RECTANGULAR REGISTER /GRILLE LINEAR DIFFUSER CIRCULAR DIFFUSER X 225 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 0 BOO City Of Tukwila ILDING _DJVZ$I0N RECEIVED CITY OF TUKWILA AUG 12 2008 PERMIT CENTER PERMIT SET Date: Job No.: Drawn By: Checked by: Filename: Revisions: M/EO.1 08/12/08 822.00 DKM JKS LEGENDS AND ABBREVIATIONS SHEET 2 OF 6 GAS FIRED BOILERS B -# MFR MODEL # TYPE CAPACITY (MBH) EFF ( °7O) MIN GAS PRESSURE ( WC) HEATING WATER ELECTRICAL COMB. AIR INTAKE PIPE DIA. () EXHAUST FLUE DIA. ( ) SHIPPING WEIGHT (LBS) DIMENSIONS (W "XH "XL ") NOTES INPUT OUTPUT LWT ( °F) EWT ( °F) FLOW (GPM) V /PH /HZ MAX AMP DRAW 1 HAMILTON EVO DUO 399 CONDENSING BOILER 399.9 379.9 95 4 180 150 25.4 208/1/60 3.15 4 4 194 25X32X27 1,2,3,4 NOTES: 1. BOILER OUTPUT AND FLOW IS SIZED FOR 75% OF THE DESIGN CAPACITY. 2. PROVIDE WITH BOILER CONTROL PANEL WITH MODULATING BOILER BURNER CONTROL AND BOILER SEQUENCING PANEL. 3. PROVIDE WITH PVC EXHAUST VENT AND COMBUSTION AIR INTAKE PIPE ASSEMBLIES. 4. PROVIDE WITH REMOTE EMERGENCY SHUTDOWN SWITCHES. AIR COOLED CHILLERS CH - # MFR MODEL COP REFRIGERANTS NOMINAL CAPACITY (TONS) DESIGN PRESSURE (PSI) WATER FLOW (GPM) EVAPORATOR DATA ELECTRICAL APPROX. WEIGHT (LBS) NOTES EWT ( °F) LWT (°F) # CIRCUITS FOULING FACTOR PRESSURE DROP (PSI) V /PH RLA MCA MAX FUSE 1 SMARDT A0610 -2K -5FV 2.88 R134A 176 190 422 54 44 3 0.0001 6.9 460/3 301 350 450 10180 MUELLER 351M 200 psi WOG 2 SMARDT A0610 -2K -5FV 2.88 R134A 176 190 422 54 44 3 0.0001 6.9 460/3 301 350 450 10180 1750 NOTES: HVAC PUMPS PIPING SYSTEM P- # MFG MODEL # TYPE SERVICE FLOW (GPM) HEAD (} BHP EFF (%) SUCTION SIZE (") DISCH SIZE (") MOTOR NOTES RPM HP V/0 1 BELL & GOSSETT 3G- SERIES 1510 BASE- MOUNTED CHILLED WATER 360 125 0.5 73 4 3 1750 20 460/3 1, 2 2 BELL & GOSSETT 3G- SERIES 1510 BASE - MOUNTED CHILLED WATER 360 125 MUELLER 351M 200 psi WOG 73 4 3 1750 20 460/3 1, 2 3 BELL & GOSSETT 90- 1 -1/2A IN -LINE HEATING WATER 25.4 30 0.42 47.2 1.5 1.5 1750 0.75 120/1 ALL NOTES: 1. PROVIDE WITH INLET SUCTION DIFFUSER AND DISCHARGE TRIPLE DUTY VALVE. 2. MOTOR SHALL BE VFD RATED. PIPE & EQUIPMENT INSULATION SCHEDULE PIPING SYSTEM TEMP RANGE THERMAL COND MEAN RAT TEMP INSULATION MATERIAL INSULATION THICKNESS BY PIPE SIZE NOTES RUNOUTS TO 2" 1" AND LESS GREATER THAN 1" HEATING HOT WATER <200 0.24 -0.28 180 FIBERGLASS 0.5 1.5 1.5 1 CHILLED WATER 40 -55 0.24 -0.28 45 FIBERGLASS 0.5 0.5 1 1 NOTES: 1. RUNOUTS TO INDIVIDUAL TERMINALS NOT TO EXCEED 12 FEET IN LENGTH ENERGY CODE NOTES 1 SECTION 1411.1: ALL EQUIPMENT SHALL MEET THE MINIMUM EFFICIENCY REUIREMENTS LISTED ON TABLE 14 -1A THROUGH 14 -10. SEE SCHEDULE FOR EQUIPMENT EFFICIENCIES. 3 SECTION 1416: PERFORM COMMISSIONING, TESTING AND BALANCING IN ACCORDANCE WITH WA STATE ENERGY CODE SECTION 14.16. 7 SECTION 1422: THERMOSTATS SHALL BE INTERLOCKED TO PREVENT SIMULTANWOUS HEATING AND COOLING. PIPING MATRIX SERVICE ID SERVICE DESCRIPTION LOCATION/ AREA OPERATING PRESSURE (PSIG) SIZE MATERIAL CONNECTION TYPE & FITTINGS SPEC REFERENCE FLANGES, UNIONS & CPLGS FLEX . CONNECTIONS MFR & MODEL ISOLATION VALVE TYPE ISOLATION VALVE RATING CHECK VALVE RATING BALANCE VALVE MFR & MODEL STRAINER MFR & MODEL PRESSURE GAUGE MFR & MODEL TEMPERATURE GAUGE MFR & MODEL TEST PROCEDURE NOTE: ISOLATE ALL EQUIPMENT PRIOR TO TESTING SEISMIC BRACING IMPORTANCE FACTOR NOTES MEDIA MINIMUM TEST PRESSURE MAXIMUM TEST PRESSURE MINIMUM DURATION CODE REFERENCE CHILLED WATER CHILLED WATER SUPPLY & RETURN ALL 12 2" AND SMALLER COPPER TUBE TYPE L CARBON STEEL PIPE A53B ERW STANDARD WEIGHT 95 -5 SOLDER (CU) THREADED (STEEL) SEC 230901 C x C UNION (CU) Elkhart WROT 102 M.I. UNION (STEEL) Anvil Fig. 463 Class 150 300 psi WOG UNISOURCE UPCB (CU) UNISOURCE UPCS (STEEL) BALL 600 WOG @ 250 deg F (Milwaukee BA 350 or similar) solder, 200 psi WOG (Milwaukee 1509 or similar) Nibco 51710 or Gruvlok GBV-S MUELLER 351M 200 psi WOG Winters Model LF /Q700 Winters Model 91T WATER 150% OF OPERATING PRESSURE, NOT LESS THAN 100 PSIG MAX. ALLOWABLE TEST PRESSURE ANY COMPONENT OR 90% OF YIELD NOT LESS THAN 15 MINUTES, LOWER TO OPERATING PRESSURE FOR 24 HOURS ANL PERFORM A VISUAL INSPECTION WITH NO LEAKS IMC, 2003 IMC SECTION 1208 1.0 2 -1/2" AND LARGER CARBON STEEL PIPE A536 ERW STANDARD WEIGHT 3UTTWELD OR GROOVED 150# WELD NECK FLANGE, GROOVED FLANGE OR COUPLING UNISOURCE UPCS -FLG GRUVLOK SV21 BUTTERFLY 200 psig, lug body (Milwaukee ML223B or similar) 200 psi WOG, Flanged, Horizontal use only Gruvlok 7800 Series, 300 psig WOG (Milwaukee F- 2974 -M or similar) Gruvlok GBV -G Dezurik PEC plug valves, cast iron, 175 psig WOG (for use on pump discharge) MUELLER 758 or MUELLER 165 200 psi WOG (2" to 12 ") 150 psi WOG (14" to 24 ") Gruvlok 758G HEATING HOT WATER HEATING HOT WATER SUPPLY &RETURN ALL 12 2" AND SMALLER COPPER TUBE TYPE L 95 -5 SOLDER (CU) THREADED (STEEL) SEC 230901 C x C UNION (CU) Elkhart WROT 102 M.I. UNION (STEEL) Anvil Fig. 463 Class 150 300 psi WOG UNISOURCE UPCB (CU} UNISOURCE UPCS (STEEL) BALL 600 WOG © 250 deg F (Milwaukee BA -350 or similar) solder, 200 psi WOG (Milwaukee 1509 or similar) Nibco 51710 or Gruvlok GBV -S MUELLER 351 M PLf 200 psi WOG Winters Model LF /Q700 Winters Model 9IT WATER 30% GLYCOL 150% OF OPERATING PRESSURE MAX. ALLOW ABLE PRESSURE ANY COMPONENT ° OR 90% OF YIELD NOT LESS THAN 15 MINUTES, LOWER TO OPERATING PRESSURE FOR 24 HOURS AND PERFORM A VISUAL INSPECTION WITH NO LEAKS ASME B31.9 1.0 REVIEwED FC CO APPROVE AUG 2 0 2p08 IOT uIIa DN I 2 -1/2" AND LARGER CARBON STEEL PIPE A5 ERW STANDARD WEIGHT BUTTWELD OR GROOVED 150# WELD NECK FLANGE, GROOVED FLANGE OR COUPLING UNISOURCE UPCS -FLG GRUVLOK SV21 BUTTERFLY 200 psig, lug body (Milwaukee ML223B or similar) 200 si WOG, Flan ed, p g Horizontal use only Gruvlok 7800 Series, 300 psig WOG (Milwaukee F- 2974 -M or Gruvlok GBV -G Dezurik PEC plug valves, cast iron, 175 psig WOG far use an pump discharge) (for p e 9) MUELLER 758 or MUELLER 165 200 psi WOG (2 to 12 ") 150 psi WOG (14" to 24 ") Gruvlok 758G NOTES: GOB 228 VC � RECEIVED CITY OF TUKWILA AUG 121UUU PERMIT CENTER PERMIT SET i z J Z W W OLU = U Q W w W J � CO W � J o -J ox U Date: 08/12/08 Job No.: 822.00 Drawn By: DKM Checked by: JKS Filename: Revisions: SCHEDULES - MECHANICAL M0.2 SHEET 3 OF 6 t r- SITE PLAN - MECHANICAL 1/16 m 1' -4 alacE ( ■ PROVIDE PRESSURE !I REGULATOR CAPABLE OF MAINTAINING 7" TO 11" WC OUTLET PRESSURE. WORK AREA. SEE WORK AREA. SEE 1 I WORK AREA. SEE EXISTING GAS METER EXISTING GAS MAIN GENERAL NOTES: ROUTE 1 -1/4" G FROM EXISTING GAS MAIN DOWN STREAM OF METER TO MECH ROOM 141. NEW GAS PIPING SHALL BE INSTALLED APPROXIMATELY 9'—O" AFF, AND ATTACHED SECURELY TO EXTERIOR WALL BY PIPE HANGERS OR CLAMPS. I, ,—(E)1 -1/2" GAS PIPING ON ROOF 1 -1 /4" DN. SEE M3.1 FOR CONTINUATION 1. EXISTING BUILDING LAYOUT SHOWN IS DIAGRAMMATIC AND MAY NOT BE ACCURATE. CONTRACTOR SHALL FIELD VERIFY EXISTING BUILDING LAYOUT PRIOR TO PERFORMING ANY WORK. RfVitWt0 FOR CODE COMPLIANCE APPROVED AUG 2 0 2008 CaY (�� Tukwila BUILDING DIVISION 1)08-w22.5 RECEIVED CITY OF TUKWILA AUU 1 2 2008 PERMIT CENTER PERMIT SET z Date: Job No: Drawn By: Checked by: Filename: Revisions: J Z W W OLU :I:Q Wa W w w � J � m W n 0 J D 2 0 0 LcS Q) H 08/12/08 822.00 DKM JKS SITE PLAN - MECHANICAL & ELECTIRCAL M/E1.O SHEET4OF6 Ur (E)PANEL - W TO REMAIN 1/4 = 1'-0' A 1( DEMO PLAN - MECH ROOM 141 1/4 = V -0 DEMO PLAN - CHEF'S OFFICE L GENERAL NOTES: 1. EXISTING BUILDING AND MECHANICAL EQUIPMENT LAYOUTS SHOWN ARE DIAGRATIC AND MAY NOT BE ACCURATE. CONTRACTOR SHALL HELD VERIFY EXISTING BUILDIGN AND EQUIPMENT CONDITIONS PRIOR TO PERFORMING ANY WORK. KEY NOTES: 0 EXISTING 40KW UNIT HEATERS AND ASSOCIATED CONTROL DEVICES TO REMAIN. DEMO EXISITNG LINE VOLTAGE WIRING FROM UNIT HEATER TO ASSOCIATED PANEL. M2.1 [t DEMO PLAN - MECH ROOM 133 r d 71 Q H �� GENERAL NOTES: 1. EXISTING BUILDING AND MECHANICAL EQUIPMENT LAYOUTS SHOWN ARE DIAGRATIC AND MAY NOT BE ACCURATE. CONTRACTOR SHALL FIELD VERIFY EXISTING BUILDIGN AND EQUIPMENT CONDITIONS PRIOR TO PERFORMING ANY WORK. 2. KEY NOTES: 0 DEMO EXISTING CHILLER AND ASSOCIATED CONTROL DEVICES, MAINTAIN EXISTING CHILLER AND CONNECTED PIPING IN OPERATION UNTIL NEW CHILLER IS INSTALLED, TESTED AND READY TO BE CONNECTED TO EXISTING CWS AND CWR PIPING. ONCE NEW CHILLER AND CHILLED WATER PIPING IS COMPLETELY INSTALLED, DEMO EXISTING CHILLER AND ASSOCIATED CONTROL DEVICES. DEMO EXISTING CHILLED WATER PUMP AND BRANCH PIPING AS TO ALLOW INSTALLATION OF NEW PUMPS AND PIPING ACCESSORIES. DISCONNECT POWER FEED TO PUMP PRIOR TO DEMOLITION OF PUMP. EXISTING JUNCTION BOX TO REMAIN. REMOVE POWER FEED TO EXISTING CHILLER. REMOVE EXISTING 400A CHILLER DISCONNECT SWITCH. EXISTING 400A CHILLER DISCONNECT TO REMAIN. DEMO EXISTING CHILLED WATER SUPPLY AND RETURN PIPING UP TO WALL PENETRATIONS. EXISTING WATER HEATER TO REMAIN. DEMO EXISTING CHILLED WATER SUPPLY AND RETURN RISERS. DEMO EXISTING CHILLED WATER SUPPLY AND RETURN PIPING. Rtv1tvvtt) pwc CODE COMPLIANCE APPROVED AUG 2 0 2808 City Of 7 B ILDING DIVISION X6 O922S RECEIVED CITY OF TUKWILA HuU 1 2 1008 PERMIT CENTER PERMIT SET z z Date: Job No.: Drawn By: Checked by: Filename: Revisions: z z f'1 z 0 LCS LCD P'C P v E-■ DEMO PLAN - MECHANICAL & ELECTRICAL M /E2.1 08/12/08 822.00 DKM JKS SHEET' 5 OF 6 iI — I , \ 1., I. / 1 \ I\ , I 0 it i Ur (E)PANEL - W TO REMAIN 1/4 = 1'-0' A 1( DEMO PLAN - MECH ROOM 141 1/4 = V -0 DEMO PLAN - CHEF'S OFFICE L GENERAL NOTES: 1. EXISTING BUILDING AND MECHANICAL EQUIPMENT LAYOUTS SHOWN ARE DIAGRATIC AND MAY NOT BE ACCURATE. CONTRACTOR SHALL HELD VERIFY EXISTING BUILDIGN AND EQUIPMENT CONDITIONS PRIOR TO PERFORMING ANY WORK. KEY NOTES: 0 EXISTING 40KW UNIT HEATERS AND ASSOCIATED CONTROL DEVICES TO REMAIN. DEMO EXISITNG LINE VOLTAGE WIRING FROM UNIT HEATER TO ASSOCIATED PANEL. M2.1 [t DEMO PLAN - MECH ROOM 133 r d 71 Q H �� GENERAL NOTES: 1. EXISTING BUILDING AND MECHANICAL EQUIPMENT LAYOUTS SHOWN ARE DIAGRATIC AND MAY NOT BE ACCURATE. CONTRACTOR SHALL FIELD VERIFY EXISTING BUILDIGN AND EQUIPMENT CONDITIONS PRIOR TO PERFORMING ANY WORK. 2. KEY NOTES: 0 DEMO EXISTING CHILLER AND ASSOCIATED CONTROL DEVICES, MAINTAIN EXISTING CHILLER AND CONNECTED PIPING IN OPERATION UNTIL NEW CHILLER IS INSTALLED, TESTED AND READY TO BE CONNECTED TO EXISTING CWS AND CWR PIPING. ONCE NEW CHILLER AND CHILLED WATER PIPING IS COMPLETELY INSTALLED, DEMO EXISTING CHILLER AND ASSOCIATED CONTROL DEVICES. DEMO EXISTING CHILLED WATER PUMP AND BRANCH PIPING AS TO ALLOW INSTALLATION OF NEW PUMPS AND PIPING ACCESSORIES. DISCONNECT POWER FEED TO PUMP PRIOR TO DEMOLITION OF PUMP. EXISTING JUNCTION BOX TO REMAIN. REMOVE POWER FEED TO EXISTING CHILLER. REMOVE EXISTING 400A CHILLER DISCONNECT SWITCH. EXISTING 400A CHILLER DISCONNECT TO REMAIN. DEMO EXISTING CHILLED WATER SUPPLY AND RETURN PIPING UP TO WALL PENETRATIONS. EXISTING WATER HEATER TO REMAIN. DEMO EXISTING CHILLED WATER SUPPLY AND RETURN RISERS. DEMO EXISTING CHILLED WATER SUPPLY AND RETURN PIPING. Rtv1tvvtt) pwc CODE COMPLIANCE APPROVED AUG 2 0 2808 City Of 7 B ILDING DIVISION X6 O922S RECEIVED CITY OF TUKWILA HuU 1 2 1008 PERMIT CENTER PERMIT SET z z Date: Job No.: Drawn By: Checked by: Filename: Revisions: z z f'1 z 0 LCS LCD P'C P v E-■ DEMO PLAN - MECHANICAL & ELECTRICAL M /E2.1 08/12/08 822.00 DKM JKS SHEET' 5 OF 6 HEATING WATER COIL (E)RETURN DUCT BELOW B-1 ` -GAS SHUT -OFF VALVE ®Q FLOOR PLAN - MECH ROOM 141 Ile_ 0 1 (E)PANEL - OFFICE 3 FLOOR PLAN - CHEF'S OFFICE ., i 1 -1/4" UP. SEE M1.0 , FOR CONTINUATION 1- 1 /4 "G. ROUTE PIPE AS HIGH AS POSSIBLE. GENERAL NOTES 1. INSULATE ALL PIPING IN ACCORDANCE WITH WA STATE ENERGY CODE. 2. WEATHER PROOF ALL PIPE WALL PENETRATIONS WITH MECHANICAL SLEEVES. 3. THE INTENT OF THIS PLAN IS TO PROVIDE DIACRAMATIC MECHANICAL EQUIPMENT LAYOUTS. IT IS CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL VISIBLE EXISTING CONDITIONS PRIOR TO INSTALLING NEW MECHANICAL EQUIPMENT. 4. MAINTAIN SERVICE CLEARANCES REQUIRED BY EQUIPMENT MANUFACTURERS. 5. ALL GAS PIPING SHALL BE SIZED IN ACCORDANCE WITH UPC 2006, AND BOILER MANUFACTURER'S REQUIREMENTS. KEY NOTES 01 ROUTE GAS PIPING TO BOILER GAS SUPPLY INLET. • INSTALL BOILERS ON WALL WITH UNI -STRUT RACK PER BOILER MANUFACTURER'S RECOMMENDATION. C) ROUTE 4" PVC VENT PIPE FROM BOILER OUTLET UP THROUGH ROOF AND TERMINATE WITH ONE 90' ELBOW. PROVIDE BIRD SCREEN AT END. BOILER FLUE VENT PIPING ASSEMBLY SHALL BE PROVIDED BY BOILER MANUFACTURER AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. 0 ROUTE 4" PVC COMBUSTION AIR INTAKE PIPE FROM BOILER CONNECTION UP THROUGH ROOF AND TERMINATE WITH TWO 90' ELBOWS(PIPE OPENING SHALL FACE DOWNWARD TO ELIMINATE WATER INTRUSION). PROVIDE BIRDSCREEN AT END. COMBUSTION AIR INTAKE PIPING ASSEMBLY SHALL BE PROVIDE BY BOILER MANUFACTURER AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. d ROUTE 2" HWS & HWR DN AND TO BOILER SUPPLY AND RETURN WATER PIPING CONNECTIONS. • BOILER ELECTRICAL LOAD IS 3.15AMPS. FEEDER SHALL BE 2 #12, 1#12G TYPE THHN /THWN COPPER IN 3/4" EMT CONDUIT WITH 20A DISCONNECT AT BOILER. FEED FROM PANEL - W, CIRCUIT NO. 36 & 38. d PUMP ELECTRICAL LOAD IS 7.6AMPS. FEEDER SHALL BE 2 #12, 1 #12G TYPE THHN /THWN COPPER IN 3/4" EMT CONDUIT WITH 20A DISCONNECT AT PUMP. FEED FROM PANEL - W, CIRCUIT NO. 40 & 42. PROVIDE 20A, 208V, 2PHASE CIRCUIT BREAKER AT PANEL. KEY NOTES 0 UTILIZE AVAILABLE SAPRE CIRCUITS(CKT NO. 36, 38, 40 AND 42) ON EXISTING PANEL - W FOR NEW MECHANICAL EQUIPMENT, B_1 AND P -3, IN MEHCANICAL ROOM 141. (E)JUNCTION BOX 3,1 FLOOR PLAN - MECH ROOM 133 M1 1/4" = 1" -0" O GENERAL NOTES 1. INSULATE ALL PIPING IN ACCORDANCE WITH WA STATE ENERGY CODE. 2. WEATHER PROOF ALL PIPE WALL PENETRATIONS WITH MECHANICAL SLEEVES. 3. THE INTENT OF THIS PLAN IS TO PROVIDE DIAGRAMATIC MECHANICAL EQUIPMENT LAYOUTS. IT IS CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL VISIBLE EXISTING CONDITIONS PRIOR TO INSTALLING NEW MECHANICAL EQUIPMENT. 4. MAINTAIN SERVICE CLEARANCES REQUIRED BY EQUIPMENT MANUFACTURERS. KEY NOTES O CONNECT TO EXISTING CWS MAIN. • CONNECT TO EXISTING CWR MAIN. 0 PROVIDE 4" HOUSEKEEPING PAD UNDER PUMP. 04 RECONNECT ELECTRICAL POWER FEED TO NEW PUMP. ROUTE FEEDER THROUGH VARIABLE FREQUENCY DRIVE. ANY NEW FEEDER REQUIRED SHALL BE 4 #10, 1 #10G TYPE THHN /THWN COPPER WIRE IN 3/4" EMT CONDUIT. • PROVIDE NEW 400A FEEDER FROM EXISTING JUNCTION BOX TO NEW FUSED DISCONNECT. FEEDER SHALL BE 4 #600KCMIL, 1#2G TYPE XHHW -2 IN 4" EMT CONDUIT. FUSED DISCONNECT SHALL BE 400A. ALL CONDUIT CLOSURES SHALL BE WEATHER- TIGHT. REVIEWED FOR LL CODE COMPLIANCE APPROVED AUG 2 0 2008 WI i1 ©iNG DIVISION ?GOB 225 RECEIVED CITY OF TI.JKV11ILA Hub 1 21000 PERMIT CENTER PERMIT SET Date: Job No.: Drawn By: Checked by: Filename: Revisions: 08/12/08 822.00 DKM JKS FLOOR PLAN - MECHANICAL & ELECTRICAL M1E3.1 SHEET 6 OF 6