Loading...
HomeMy WebLinkAboutPermit PG08-258 - VALLEY VIEW SEWER DISTRICTVALLEY VIEW SEWER DISTRICT 14816 MILITARY RD S PGO8-258 Parcel No.: 0041000083 Address: Suite No: City Ilif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 14816 MILITARY RD S TUKW Permit Number: Issue Date: Permit Expires On: PG08 -258 10/09/2008 04/07/2009 Tenant: Name: Address: Owner: Name: Address: VALLEY VIEW SEWER DISTRICT 14816 MILITARY RD S , TUKVVILA WA VAL VUE SEWER DIST PO BOX 69550 , SEATTLE WA Contact Person: Name: ROBERT WALSH Address: PO BOX 2355 , BELFAIR WA Contractor: Name: BEISLEY INC Address: 230 MAPLE WOOD CT NE , BELFAIR, WA Contractor License No: BEISLI *027LC Phone: Phone: 360 - 731 -5614 Phone: Expiration Date: 10/01/2009 DESCRIPTION OF WORK: GAS PIPING WITH (4) OUTLETS TO FEED (1) WATER HEATER, (2) HEAT PUMPS AND (1) FUTURE APPLIANCE. Value of Plumbing /Gas Piping: Fees Collected: $2,000.00 $115.00 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 0 Shower, single head trap 0 Lavatory 0 Wash fountain Receptor, indirect waste 0 Sinks 0 Urinals 0 Water Closet 0 0 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and/or vent 0 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 0 Medical gas piping (6 +) inlets /outlets 0 Gas Piping Gas piping outlets (0 -5) 4 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -258 Printed: 10 -09 -2008 City OP Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -258 Issue Date: 10/09/2008 Permit Expires On: 04/07/2009 Permit Center Authorized Signature: COAL Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: Print Name: _so Date: 7/b-- -9 ^d© This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -258 Printed: 10 -09 -2008 Parcel No.: 0041000083 Address: Suite No: Tenant: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 14816 MILITARY RD S TUICW VALLEY VIEW SEWER DISTRICT PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -258 ISSUED 09/24/2008 10/09/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -258 Printed: 10 -09 -2008 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: /6 --7-68 doc: Cond -10/06 PG08 -258 Printed: 10 -09 -2008 CITY OF TUKWIL" Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Amok ..V) Plumbing /Gas Permit No. (�Q 8- g173 Project No. IIce, use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Q�l7 rv'1 l i%ry 30d4k- Site Address: ++vKv✓t (�t t04- 1e /bb Tenant Name: otikk7 (Sc.-) S 6.4(r 01 34- - Property Owners Name: ciS ave.' Mailing Address: King Co Assessor's Tax No.: 301-1 (00 OD Qj) Suite Number: Floor: New Tenant: .... Yes D ..No City State Zip CONTACT PERSON contact when your permit is ready to be issued Name: Robe r4- 100,1.s 1 Mailing Address: Po. X A355 E -Mail Address: r(, 00 4416) b- C-,S/ay)✓!(.. eb/v1 Day Telephone: 3) ---73( ( -56 /`7 geAir lnlld %ea6 City State Zip Fax Number: 3&' 275- 853 f PLUMBING / GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: CO aielUe__. Contact Person: E -Mail Address: Contractor Registration Number: & '51/ .21 L( City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD All plans must be wet stamped by chitect. of Recoir Company Name: lGi 1,2.eard N�q Mailing Address: ! c v ►� a K1- t- Drag Contact Person: E -Mail Address: G-K6 vue, 14- 9'g033 City State Zip Day Telephone: ya6— g27 Fax Number: 'Q6 ga?7 " -7O(L% ENGINEER OF: RECORD =}All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: f�c rve 45 Gi bove Q: Applications\Forms- Applications On Linel3 -2006 - Plumbing -Gas Piping Permit Application.doc Revised: 4 -2006 bh City Day Telephone: Fax Number: State Zip Page 1 of 2 tiolk Valuation of Project (contractor's bid price): $ / 4ria JJ &eQ © Scope of Work (please provide detailed information): ation): J , elvY - r�GcE¢ / a_ - -�[x5, S-� /.� 6 vi (Gzl vl pf o V t r1) n 8 i r- /LQ .-) ? 6..-5 7 6 -2 1446 f - PU n-i e 5 afi c ` 1 4 a 7' G✓ .1-e 4 Cc.1f 1'" (,✓ ‹.. 5,i -cu-I -ti( e. t ►Lt, no -f- '40 ule_ a t MLS -4/h -c See_ p144 P- (- 0 a i- .t /1/) z .O Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent 1 Additional medical gas inlets /outlets —six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas PERMIT APPLICATION NOTES of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE,.s'' A ORIZED AGENT: Signature: Print Name: Mailing Address: Datep4a /.7Q'%6 Day TelephoneS65) -73/ 6-67/ City State Zip Date Application Accepted: n Date Application Expires: Staff Initials: WK Q:\Applications\Fonns- Applications On Line \3 -2006 - Plumbing -Gas Piping Permi Application doc Revised: 4 -2006 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 0041000083 Permit Number: PG08 -258 Address: 14816 MILITARY RD S TUICW Status: PENDING Suite No: Applied Date: 09/24/2008 Applicant: VALLEY VIEW SEWER DISTRICT Issue Date: Receipt No.: R08 -03346 Initials: WER User ID: 1655 Payment Amount: $115.00 Payment Date: 09/24/2008 01:57 PM Balance: $0.00 Payee: BEISLEY INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 19461 115.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES PLAN CHECK - NONRES 000.322.103.00.0 92.00 000/345.830 23.00 Total: $115.00 i doc: Receipt -06 Printed: 09 -24 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit /JL PERMIT NO. Project: , • -e t ( .5 fType /1 �[ , •, V , of Inspg�io o 1 A / f' v /l� � n1 Addres ���� � ∎ �c-�.� C Cis Date Callt'd: � Special In tructions: Date Wanted: 2� ✓J �a.rDr p.m. Requester: Phone No: Ell Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: r‘ Ctsc__ Inspector: ' Date: Z'���`� ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: _.•• - - --. ....,a,..n • ._,. �..�_ - INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit 7)- $4' '6- PERMIT NO. Project: / VI / ��Y /? wef- Type of Inspection:, i Al- /, J /lc Address: /V//( /?iG /1 0 Date Called: Special Instructions: ..36c Date Wanted: Q — /9 Q/O p.m. Requester: Phone No: — 7.0/ ?6/6 Approved per applicable codes. Corrections required prior to approval. COMMENTS: .00 REINSPECTION EE REQUIRED..? id at 6300 Southcente lvd., Suite 10 Date: /6 -iy -06 for to inspection, fee must be Call to schedule reinspection. Refeipt No.: Date: a to INSPECTION NO. CITY OF TUKWILA BUILDING DIVISI ON 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. �( (206)431 -360 Project: V A 1 KA 1 V i e wCe�., Type of Inspectpn: �` ` v )j P ✓mot f (At bk.) d r s : 6 t I f 4 iti per. ate Called: Special Instructions: Date Wanted: lo - i -De9 �FYti p. Requester: Phon e No: 3V%0 -73 1 1bl C_. IZIApproved per applicable codes. Corrections required prior to approval. CO MENTS: _..)(4s P(P,,,,k, - tis4evivra AppPdve >4. , ....> - ,(i\- ?PfeueV Date: 10-13- El $60. I I ' EINSPECTION FEE RE UIRED. Pr or to inspection, fee must be paid = 6300 Southcenter Blvd. uite 100: Call to schedule reinspection. Receipt No.: Date: 31 I� ec-s iut�-4�b1c- 0 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Divi 'on. NOTE: visions will require a n plan submittal and ay include additional plan view fees. 1,111111p!! _ �4 I ,III f1 BLDG A SECOND FLOOR PLUMBING PLAN „, 4 SCALE: 1/8' = Cc- b I� Q 1' UNDERGROUND GAS UNE TO BUILDING B ,I ILII: IL. 1 1 /2" GAS METER<1 O ��� � -61.2 ,i Jr 1 BLDG A FIRST FLOOR [��MESTIC WATER AND GAS PLUMBING PLAN 0 SCAT 1/8' BLDG A FIRST FLOOR PLUMBING DEMO PLAN SCALE: 1/8' = 1' -0' O kit UO1,F ru.?t& 1 t,n1 ' �IIII • \ills Q E • • 't21LS , 2 W a01.- r zesois 02 AT WALL �,L•` ' 71.111 2" V UP® 3 W UP CONSTRUCTION NOTES EXISTING IAV TO REMAIN. EXISTING WC TO REMAIN. CONNECT TO EXISTING 1 -1/2' CW RISER AT ENTRANCE TO BUILDING. CONTRACTOR SHALL CONFIRM IF ISOLATION VALVE AND BFP ARE EXISTING. IF SO, CONNECT TO EXISTING. IF NOT, PROVIDE ISOLATION VALVE AND BFP IN RISER. PROVIDE PRESSURE REGULATOR SI7FD AT 50 PSI DISCHARGE PRESSURE. 3/4' CW UP. CONNET TO EXISTING CW UNE BELOW 2ND FLOOR. 1/2' HW UP. CONNECT TO EXISTING HW UNE BELOW 2ND FLOOR. ROUTE RELIEF VALVE DRAIN THRU WALL PROVIDE THERMOSTATIC MIXING VALVE ASSEMBLY IN THIS LOCATION, LEONARD MODEL TM -20E. SET AT 120' LWT. CONNECT TO EXISTING 4' VTR BELOW 2ND FLOOR. REMOVE EXISTING FIXTURE AND ASSOCIATED PIPING. REMOVE EXISTING CW UNE TO 2" AFF AT RISER. CONTRACTOR TO EVALUATE SIZE OF METER AND COORDINATE WITH GAS COMPANY TO INCREASE SIZE IF REQUIRED. 3' CONCENTRIC VENT. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. ROUTE THRU EXISTING WALL PENETRATION. REMOVE EXISTING FAN AND SHROUD. NOT USED. REMOVE EXISTING WH. PROVIDE NEW WH -1. INSULATE ALL DOMESTIC HW AND CW PIPING IN HWH ROOM. EXISTING SS TO REMAIN. CONNECT TO EXISTING WASTE BELOW SLAB INSIDE BUILDING. CONFIRM INVERT OF EXISTING WASTE PRIOR TO INSTALLATION OF BELOW FLOOR WASTE. ® ROUTE 1' G ALONG OUTSIDE WALL DROP BELOW GRADE AS SHOWN, ROUTE TO NEW BUILDING. ® CONNECT TO EXISTING GAS UNE IF ADEQUATE SIZE. SEE NOTE 11. GAS CONN. TO GENERATOR TO REMAIN. • ROUTE GAS TO HP -1, HP -2, WH -1. CONTRACTOR TO SIZE BRANCH UNE TO HEAT PUMPS. ro view approval Is subject to errors and omr ions. rovzi! G' c' nstruction documents does not authorize violation of any adopted code or ordinance. Receipt • proved Field Copy and conditions is acknowledged: REpC E I VE r e�6.r 2 4 LUW BLDG A FIRST FLOOR WASTE & VENT PLUMBING PLAN SCALE 1/8' = 1' -0' By ate: City of Tukwila BUILDING DIVISION Nio� 258 PERMIT CENTEI • FSi consulting engineers Seottle, Washington Solutions & Service 910 MARKET 9718E TEL 425.827.2 450 FAX: 425.827. 4 F- u W a 0 NN Q �.i. fY �L1 / J� Z W 0 Q Z LLJ 0 W Ltg J o BID SET J08 N0: 07.15 DATE: 5/15/2008 REVISIONS: no amax•rwerroen 01131311.11.0 W■ 10/3021,1 0133704 7.151.3/G7 M■191 eown.rn.cr nag rope. 11. coos [COT 1.31■111.2111•111111WIlla 5329 rREDI r. ECT l GALEN C.PAGE MATE CF PL UMeNG PIANS ILDG A SI ICE F P -1.0 N I) I I►'I. ARCHITE CTS - ?S KIRELAND, WA B80!] L:4 5.827.7850 AX 5.827.7014 orarmi O CONSTRUCTION NOTES PROVIDE EXHAUST FAN, COOK MODEL 210ACEB, 3200 CFM EXHAUST WITH FACTORY CURB TO MATCH ROOF SLOPE., PROVIDE BACKDRAFT DAMPER AND CONNECT TO LOUVER. SEE ARCH. FOR LOUVER DIMENSIONS. COUNTER' WEIGHT DAMPER TO OPEN' AT 10'. © PROVIDE AND MOUNT CO SENSOR' ON WALL, VERIS GW OR• EQUAL CO SENSOR TO START /STOP EF -3. INCLUDE 10 MINUTE MINIMUM RUN TIMER TO AVOID FAN SHORT CYCLING. PROVIDE TRANSFORMER TO REDUCE 115V TO 24V FOR SENSOR. PROVIDE RELAY AND CONTACTS FOR EF -3 CONTROL BY CO SENSOR. o � BLDG B FIRST FLOOR HVAC PLAN SCALE: 1/8" = CODE COM NCE APPROVED SEP 3 0 2008 City Of TukWiIa E!lILDING DIVISION ArAr KEYPLAN SCALE NONE I I I I II 4 RECEIV/Fr SEP 2 4 2008 PERMIT CENTE V L1J Q W c/ C9 W co Ww W w C12 O W� J � J z 2 BID SET JOB N0: 07.15 DATE: 5/15/2008' REVISION& PALL PQM AM OR (IMISMII1711, rot xtrnoa no man a. essettica or la Mu" n coma A5328 f1REGISTEREOI 1 t ARCHITECT GALEN C.PAGE SLATE OF • FSi consulting engineers Seattle, Washington Solutions & Service 1. 61 kb4 U U - i, 1r *4 4 , . V■111111111 MEM %MEM rAm-mai, 1 9• GAS UNDERGROUND FROM BUILDING A I Ilk ' © ° WA 1' GAS MOUNT AGAINST LL. CAP AT 18' AFF I -- - - -_ -- - /Mr --- •- - - -�_J o � BLDG B FIRST FLOOR HVAC PLAN SCALE: 1/8" = CODE COM NCE APPROVED SEP 3 0 2008 City Of TukWiIa E!lILDING DIVISION ArAr KEYPLAN SCALE NONE I I I I II 4 RECEIV/Fr SEP 2 4 2008 PERMIT CENTE V L1J Q W c/ C9 W co Ww W w C12 O W� J � J z 2 BID SET JOB N0: 07.15 DATE: 5/15/2008' REVISION& PALL PQM AM OR (IMISMII1711, rot xtrnoa no man a. essettica or la Mu" n coma A5328 f1REGISTEREOI 1 t ARCHITECT GALEN C.PAGE SLATE OF • FSi consulting engineers Seattle, Washington Solutions & Service -f A ,-- 199 000 37-1) = - ISZ,. , d✓ r tip 2 - 4,46w____37--„ _ d, (0 rD ' 147 5 - )tb,0E,0 art) : q° ' 9 d Doe _)( - /,, . , IP ' 0 A( / / - /, 1 i./l 61/v rya ..1 _ 3? 4 2 7 B FL COPY 7 ; Ptermit vv�co_ p 4kfitlifitLIA04) -„ FP 1.; 04, 288 40 04470 t s .4 tv-Gwx-s-8 RECEIVED SEP 24 Ai; PERMIT CENTER 4 ° FUEL PIPING Table 12 -7 Sizing of IPS Gas Piping 1/2 3/4 Length feet 10 174 363 684 -20 119 T 249 470 - - 30 96 200 377 -40-1- 0 1 82 - 171 323 50_ _ 73 -152 286 60- - 66 138 259 70 61 _ -_- 127 239 80 56 118 222 90 53 111 208 100 y 50 104 197 - 125 - 44 T= 93 174 150 40 84 158 200 34 72 135 250 30 64 120 300 28 58 109 350_ _ 25 53 100 _400 24 49 93 450 - 22 46 87 500 21 - 44 82 550 20 42 78 600 19 40 75 1 1 -1/4 Gas Pressure Drop S Pipe Size, inches 1 -1/2 2 ecific Gravi 2 -1/2 Table 12 -7 Natural 0.5 in. w.c. _ 0.60 3 - -1 3 -1/2 4 Maximum Capacity in Cubic Feet of Gas per Hour 1,404 2,103 4,050 6,455 11,412 16,709 4,437 965 1,445 775 663 588 1,161 993 2,784 7,843 11,484 2,235 3,563 880 1,913 532 798 1,696 1,536 3,049 2,703 6,299 9,222 5,391 7,893 2,449 4,778 6,995 4,329 6,338 490 734 1,413 2,253 456 683 1,315 2,096 3,983 5,831 p23,277 I 15,998_ 12,847 10,995 9,745 8,830 8,123 3,705 5,425 428 641 1,234 1,966 404 605 1,165 358) 324 536 486 1,033 936 278 246 223 205 191 179 169 161 153 416 801 1,857 1,646 1,492 3,476 5,090 7,557 7,091 3,284 4,808 2,910 4,261 2,637 3,861 1,277 369 334 307 286 268 253 241 230 710 643 592 551 517 488 463 442 1,131 1,025 943 877 823 778 2,257 3,304 739 705 6,698 5,936 5,378 4,603 2,000 2,929 4,080_ 1,812 2,654 3,697 1,667 2,441 3,401 - 1,551 2,271 3,164 1,455_ 2,131 2,968 1,375 2,013 2,804 - 1,306 1,912 2,663 1,246 1,824 2,541 RECE VFr SEP MOW 2008 PERMIT CENTEr 167 te BRADFORD WHITE® B.,D�_A C O R P O R A T 1 0 N �T'� � lit, :, °- Commercial Ga'er�,ig Ultra High Efficiency Water 1 'e Photo is of EF-1 00T-1 99 Py The Ultra High Efficiency Water Heater Models Feature: • Thermal Efficiency Up To 99.1%. • 60 Gallon Tank Capacity In 125,000, 150,000 and 199,999 BTU /hr Inputs. • 100 Gallon Tank Capacity in 150,000,199,999, 250,000, 300,000 and 399,999 BTU /hr Inputs. • Flexible Venting — Conventional, Through- the -Wall or Direct Vent. • Three Pass Flue System. • Low NOx Premix Power Burner. • Ultra Quiet Operation. • Submerged Combustion Chamber. 1" NPT Side Connection For Hydronic Applications. • • Electronic Controls. • Zero Inch Clearance To Combustibles. • Vitraglas° Lined Tank. • Four Protective Magnesium Anode Rods (except EF -100T -399). ■ Powered Anode Rods (only EF -100T -399). • Hand Hole Cleanout Allows inspection of tank i • Factory Installed Hydrojef Sediment Reductio • Factory Installed Dielectric Fittings. • Non -CFC Foam Insulation. • 3" Optional Concentric Vent Kit. • ASME Construction Available. • NSF Construction Available With Optio • Brass Drain Valve. • T &P Relief Valve Factory Installed. • Three Year Limited Warranty On Steel ■ One Year Limited Warranty On Parts. ?f,O B2SS erior. RECEIVED SEP 2 4 2008 PERMIT CENTER 3 or 5 -Year Limited Tank Warranties / 1 -Year Limited Warranty on Component Parts. For more information on warranty, please visit www.bradfordwhite.com For products installed In USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty Included with the heater. .. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 7,063,133 82; 5,954,492; 5,954,492; 5,781,379: 5,943,984; 5.081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822 5,372,185: 5,485,879; 5,277.171; (91)5,341.770: 5.650,165; 5,596.952; 5,682.666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,358; 5,115,787; 5,092,519; 5,052,348; 4,418,222; 4,628,184; 4,861,968. 4,672.919; Re. 34,534. OTHER U.S AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1272,914; 1,280,043; 1,289,832; 2,045,882; 2,112,515; 2.108,186: 2,107,012: 2,092.105. vifraplas• and Hydmlet • are registered trademarks at Bradford White• Corporation. ®2006, Bradford While Corporation. All rights reserved. Printed In U.S.A. Ultra High Efficiency Water Heaters eF Series° Standard Equipment Features: Thermal Efficiency up to 99.1% —Fully condensing design. Three Pass Flue System—The three pass flue system keeps the hot combustion gases moving at a high velocity. The combination of high turbulence and velocity causes an enormous rate of heat transfer into the water. Low 140x Premix Power Burner — Developed for the eFSeries °, a turbulent flame shoots down the submerged combustion chamber. This turbulence causes a thorough mixing of the gas and air for optimum combustion and high heat transfer efficiencies. — Far exceeds California emission requirements. Submerged Combustion Chamber — Submerging the combustion chamber in the center of the water storage tank minimizes radiant heat loss and improves efficiency. Non -CFC Foam Insulation— Surrounds the tank surface, saving energy by retarding loss of heat. Electronic Controls— Adjustable electronic thermostat for, control between 80 °F and 180°F. The recycling Energy Cut Off (ECO) shuts off all gas flow in an event of an overheat condition. Zero Inch Clearance —The eFSeries• jacket is cool to the touch and is approved for zero inch clearance to combustibles for unsurpassed installation flexibility. Vitraglas• Lined Tank — Bradford White's water heater tanks are protected from the corrosive effects of hot water by an exclusive ceramic porcelain -like coating. Our high silica Vitraglas° lining provides a tough Interior surface for Bradford White's water heater tanks. Protective Magnesium Anode Rods — Employed to provide an extra measure of corrosion protection for longer life. Each eF heater has 4 anodes, except the EF -100T 399 which has 2 powered anode rods and one non - powered anode rod. Factory Installed Hydrojet• Sediment Reduction System —Cold inlet sediment reduction device made of stainless steel for increased durability. Helps prevent sediment build up in tank. Factory Installed Dielectric Fittings —All heaters equipped with special water heater nipples for longer heater life. No special dielectric fittings to buy. eF Series° Optional Equipment Features: Maxitrol Gas Pressure Regulating valve— Ensures proper supply pressure to eF unit of 7" to 11' W.C. (provided incoming pressure is between 1/2 and 2 psi). This can be ordered as a separate part, or as part of the heater. For the separate part, please use p/n 243 - 45517 -00 (not available for use with the EF -100T -399). Concentric Vent Terminal Kit-3" termination fitting provides for only one exit opening through wall or roof (p /n 239 - 44069 -01). NSF Compliance Kit —p /n 265 - 44542 -04. Flexible Venting —The eF Series° can vent vertically or horizontally with either 3" or 4" PVC, CPVC or ABS vent pipe, and is approved for direct vent closed combustion applications, or those applications that require inside air for combustion. Foam Core pipe is permitted on hefentire venting system. The eF Series° is also approved unbalanced venting, which means the air intake pipe doesn't have to be vented the same distance as the exhaust. (NOTE: Air intake cannot exceed exhaust by more than 30 feet.) Model Number Max. 3" PVC, ABS & CPVC Max. 4" PVC, ABS & CPVC EF -60T -125 120 ft. 170 ft. EF -60T -150 100 ft. 150 ft. 'EF -60T -199 80 ft. 130 ft. EF -100T -150 120 ft. 170 ft. EF -100T -199 100 ft. 150 ft. EF -100T -250 80 ft. 130 ft. EF -100T -300 60 ft. 110 ft. EF -100T -399 50 ft. 100 ft. Determining required vent length 1. Determine the total length of straight vent pipe (in feet) required for both the intake and the exhaust. 2. Add 5 feet of venting for every 90' elbow. 3. Add 2 12 feet of venting for every 45' elbow. 4. Total vent length cannot exceed 'Max Length" in the above venting table. 5. Air intake cannot exceed exhaust by more than 30 feet in any venting situation. NOTICE: Do not include the 3" exhaust elbow or vent terminals in determining maximum vent length. Three'year limited warranty on steel tank — Heavy gauge steel automatically formed, rolled and welded to assure a continuous seam for glass lining. One year limited warranty on parts Vent Exhaugt Intake/ Combustion Rain Capes Air 46'/.' p/n 239 - 44069 -01 Ultra High Efficiency Water Heaters Drain Gas Inlet B 28'% T & P Valve Cleanouutt 1 I D(HAUST 1-r - D 'A' ONNECTION�� NOTE: Diagrams are for both the 80 and 100 gallon models. NPT Gas Inlet 3' PVC Air Inlet 1W NPT Outlet 1' NPT Space Heating Outlet 1' NPT Space Heating Return VA' NPT Inlet -"- /.a��y6111� 3' PVC Exhaust eF Series® Commercial Ultra High Efficiency Water Heater Meettdorr edASHRAE90. anc rentsta standard) nEC.Listed NATURAL GAS AND LIOUID PROPANE GAS Model Number Input V V V V V V V • • • • • • • • * * * * * * * EF- 60T-125E -3N(A) EF-60T- 150E -3N(A) EF -607- 199E -3N(A) EF -100T- 150E -3N(A) EF -100T- 199E -3N(A) EF -100T- 250E -3N(A) EF100T- 300E -3N(A) EF- 1097 - 399E -3N(A) Model Number BTU 125,000 150,000 199,999 150,000 199,999 250,000 300,000 399,999 Input V V V V • • • • • * * * * * EF- 60T- 125E -3N(A) EF -607- 150E-3N(A) EF-60T- 199E -3N(A) EF100T- 150E -3N(A) EF -1007- 199E -3N(A) V V V For propane gas models change suffix "N' to "X" and remove 'E" from the model number. Example: EF- 1007- 150-3X V - 115V A.C. Required • - Electronic Ignition * - Listed with California Energy Commission (A) ASME - All models are available with ASME construction. To order ASME construction add the (A) to the end of the model number. Example: EF- 80T- 125E -3NA • • • * * * EF -1007- 250E -3N(A) EF -1007- 300E -3N(A) EF -100T- 399E -3N(A) kW 36.6 43.9 58.6 43.9 58.6 73.2 87.9 117.2 gin Hour Deliver/ 811001 Rise Gal. 187 211 265 250 309 364 405 521 Recovery GPH at Degree Rise 401 100'F 1401 Sto. Capacity U.S. Gal. Therm. E8. A Roor In Top of Heater in. B Jacket Dia. in. C HW Out In. D Cold In in. E Roor to Gas Conn. in. Roor to Vent Outlet in. G Floor to Alr Intake In. H Floor to T&P Conn. in. Water Conn. Dia. in. Gas Conn. Dla. In. Relief Valve Open in. Approx. Shipping Weight 364 145 104 423 169 121 60 60 96.0 57 28'/4 42 13 5342 5 521/, 40 1'/: 4/ 3/4 93.0 57 28'/4 42 13 53'/2 5 52'/2 40 11/1 3/4 3/4 558 223 159 60 92.0 57 281/4 42 13 53'/2 52.'h .40 14,. 3/4 ... 3/4 450 180 129 597 239 171 100 99.1 775/2 28111 63 13 743/4 5 73'/2 60 1' /t 3/, 'h 100 98.5 775/2 281/4 63 13 74'11 5 73'11 , 60 11/2 3/4 3/4 735 294 210 836 335 239 100 97.0 77" 2844 63 13 7442 5 731/e 60 11/2 3/4 } 100 92.0 775/, 28114 63 13 74'11 5 73'/e 60 142 3/4 1 1127 451 322 100 93.0 77th 281/4 63 13 731/4 5 73 ',2 60 11/2 1 1 la Hour Delivery et 56'C Rise Liters 708 799 1003 946 1170 1378 1533 1972 Recovery LPH et Degree Rise 22'C 56'C 78'C 1378 545 394 1601 640 458 3112 844 602 1703 681 488 2260 905 647 2782 1113 795 Stg. Capacity Liters Therm. EH. A Roor to Top of Heater MM. B Jacket Dia. mm. HW Out mm. D Cold In mm. E Floor to Gas Conn. MM. Flom to Vent Outlet MM. 0 Floor to Air Intake mm. Roor to T &P Conn. mm. Water Conn. Dia. MM. Gas Conn. Dla. mm. Relief Valve Open MM. lbs. 570 570 570 900 900 900 900 950 Approx. Shipping Weight 227 227 227 379 379 379 96.0 93.0 92.0 99.1 98.5 97.0 1448 1448 1448 1972 1972 3165 1268 905 4286 1707 1219 379 379 92.0 93.0 1972 718 718 718 718 718 718 1067 1067 1067 1600 1600 1600 330 330 330 330 330 330 1359 1359 1359 1899 1899 1899 128 128 128 128 128 128 1324 1324 1324 1857 1857 1857 1857 994 994 994 1527 1527 1527 1527 38 38 38 38 38 38 38 19 19 19 19 19 19 19 19 19 19 19 19 25 1972 718 1600 330 1899 128 1972 718 1600 330 1861 128 1857 1524 38 25 25 25 Note: The weight is the same for both ASME and Non -ASME models. NSF Construction Ave/able with optional kit Complies with SCAOMD low NOx requirements -10.39 ng/)oule Design certified by CSA International (formerly AGA/CGA) Amp Draw range = 1.0 to 1.8 amps and 7.0 amps for EF -1007 -399 150 PSI Working Pressure (1034 Id'a), 300 PSI Test Pressure (2068 kPa) kgs. 259 259 259 408 408 408 408 431 Ultra High Efficiency Water Heaters All models are design certified by CSA International (formerly AGA/CGA) for up to 180 °F (82 °C) application as an Automatic Storage Heater, and an Automatic Circulating Tank Heater. As an Automatic Storage Heater, all models are complete self - contained water heating systems. It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it will supply 180 °F (82 °C) sanitizing and 140 °F (60 °C) general purpose hot water simultaneously. These models can be used either as a single unit or as multiples connected in parallel. • 6 . Sample Specification `y The water heater shall be a Bradf•� �e model a mFlni m recovery of storaGPH LPH at 100 °F (56 °C) temperature lrise, liters, a minimum gas input of 1 and a Thermal Efficiency Rating of ^%_ It shall be design certified by CSA International (formerly AGA and CGA) for 180 °F (82 °C) application, either with or without a separate storage tank. The tank shall be lined with Vitraglas• vitreous enamel and shall have a bolted hand hole cleanout. The tank shall have four extruded magnesium anode rods Installed in separate head couplings (up to 300,000 BTU /hr input) or two powered anode rods and one extruded magnesium anode rod (for 399,999 BTU /hr input). This water heater shall be equipped with stainless steel cold water inlet, Hydrojet° Sediment Reduction System. The heater shall be insulated with Non -CFC foam. This water heater shall be equipped with an electronic using either 3* ignition system, an ASME rated T &P relief valve and a premix closed com us iwater system for direct t e tory assembled and (76mm) or 4° (102mm) PVC, CPVC or ABS vent pipe. (1 15V AC required). The tested. The water heater shall be approved for zero inch clearance to combustibles. The control shall be an adjustable electronic thermostat to any temperature up to 180 °F (82 °C). A recycling Energy Cut Off (E.C.O.) shuts off all gas in the event of an overheat condition. The entire installation shall be made in compliance with state and local codes and ordinances. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. BRADFORD WHITE ° ° • 1, ° ■ A T l ° • Ambler, PA For U.S. and Canada field service, contact your professional Installer or local Bradford white sales representative. 1 1 F 269-795-1089 Sales 800- 523 -2931 • Fax 215 -641 -1670 / Technical Support 800 - 334 -3393 • Fax 269- 795 -1089 • Warranty International: Telephone 215 -641 -9400 • Telefax 215- 641 -9750 / Fax on Demand 888-538-7833/ www.bradfordwhite.com BRADFORD WHITE- CANADA' INC. Sales / Technical Support 866. 690 -0961 /905- 238-0100 • Fax 905- 238 -0105 / www.bradfordwhitecanada.com Count On Bradford White For Everything Hot Water'" 02006, Bradford White Corporation. All rights reserved. Printed In USA 800 -B- 1006 -A -1-P1 S µ Pol,. NFINITY'" ICS MODEL 58MVC LUXE-4—WAY MULTIPOISE VARIABLE —SPEED MULTI =STAGE CONDENSING GAS FURNACE Merles 100 Input Rates k '60,000thru120,000 Btuh` Turn to the Experts Product Datp,,_ L O IdealC m f t_ IdeaHumidi y REVIEWED FOR CODE COMPLIANCE APPROVED EP 3 0 2008 E • n, IdealComfort' technology, the ultimate in heating comfort... The Carrier Infinity ICS with IdealComfortr" technology achieves the optimum combination of comfort and efficency. The Infinity ICS achieves industry- leading ultra -high efficiency at up to 95 percent Annual Fuel Utilization Efficiency (AFUE). Efficient performance is enhanced through the variable -speed design. To optimize heating performance, IdealComfort"' automatically adjusts the heating level, maximizing the use of low heating levels that produce near silent furnace operation while meeting the exact heating needs. This unit is designed to keep the indoor temperature within less than 1 degree of the thermostat setpoint. Because it operates in low heat most of the time, the Infinity'" ICS uses up to 80% less power than single- capacity furnaces. In addition to providing ultimate comfort, the Infinity" ICS has a sealed combustion system. This system brings combustion air to the furnace and vents flue gases outside the furnace in a safe manner. Because it is sealed, operational noise is minimal. A sealed combustion system also means fewer cold drafts and less air infiltration. Quality materials ate the key behind the Infinity'" ICS's outstanding performance. Carrier stands behind quality. We offer lifetime warranty protection* on the heat exchangers, the heart of the Infinity " ICS. The rest of the furnace is backed by a limited 5 -year warranty. A05069 The Infinity ICS is available in 5 heat /airflow combinations. The unit has a 4 -way multipoise design and can be installed in upflow, downflow, or horizontal positions covering up to 20 different applications. The Infinity'" ICS can be vented as a Direct vent/2 -pipe furnace or as an optional ventilated combustion air application. The versatile 4 -way multipoise design in conjunction with variable speed makes the Infinity'" ICS ideal for use with split system cooling, including 2 -speed units. A Carrier Infinity '" air purifier, humidifier, comfort ventilator, and Infinity"' Zone control will provide year round comfort and efficiency. Designed for durability, comfort, and reliability, the Infinity° ICS is the ultimate in versatile, efficient comfort. Carrier Infinity® System — When the Infinity" ICS variable -speed gas furnace is matched with the Infinity'" Control ( -B release is compatible) and an air conditioner or heat pump, the homeowner will experience the ultimate in ldealCornfort"' and IdealHumidity " through unparalleled control of temperature, humidity, indoor air quality, and zoning. The Carrier Infinity " System also provides unprecedented ease of use through onscreen, text -based service reminders and equipment malfunction alerts. PG08- RECEIVED SEP 2 4 2008 PERMIT CENT& For even greater comfort and convenience, match the infinity'" ICS furnace with an Infinity air conditioner or heat pump. This will create a fully communicating system, requiring only 4 thermostat wires between system components. In some cases, troubleshooting can even be done from the outdoor unit without entering the home. Optional remote access through telephone or Internet is also available when combined with a remote connectivity kit. Infinity'" ICS FEATURES / BENEFITS IdealHumidity"—The IdealHumidity system actively controls both temperature and humidity in the home to provide the best comfort all year long. Other systems depend on heating or cooling to manage the moisture in the air. But, IdealHumidity " gives the homeowner the right amount of humidity day and night, even in mild weather. No other manufacturer can do this! IdealHumidity saves energy, too. By keeping humidity under control, the homeowner can set their thermostat to stay comfortable and save energy —up to 20% off their cooling costs! IdealComfort"' —On the coldest days of the year, the Infinity" ICS Furnace has the capacity to heat the home. On moderate days when less heat is required, this fumace will regulate itself to a lower capacity — providing a comfortable horn and minimizing operating costs. The patented algorithm and the VariPhase "gas valve adjusts the low heat operating time to match the indoor conditions. Reliable Heat Exchanger Design —The primary heat exchanger is made of aluminized steel for corrosion resistance. The patented Serpenntff'" condensing heat exchanger cells are laminated with polypropylene for greater resistance to corrosion and epoxy coated externally to prevent oxidation. This break - through in heating technology helps extend the life of the furnace for years of dependable performance. The heat exchanger is positioned in the furnace to extract additional heat. Staiuless steel 409 coupling box componentry between heat exchangers has exceptional corrosion resistance in natural gas and propane applications. Power Heat" Igniter — Carrier's unique SiN igniter is not only physically robust but it is also electrically robust- It is capable of running at line voltage and does not require complex voltage regulators as do other brands. This unique feature further enhances the reliability of Infinity'" ICS gas furnace and continues Carrier's tradition of technology leadership and innovation in providing a reliable and durable product. ComfortFan"—Improves comfort all year long by allowing selection of the continuous fan speed right at the thermostat. SmartEvap'"—Allows the system to reduce summertime humidity levels by nearly 10% over standard systems. Media Filter Cabinet — Enhanced indoor air quality in the home is made easier with our media filter cabinet —a standard accessory on all deluxe furnaces. When installed as a part of the system, this cabinet allows for easy and convenient addition of a Carrier high efficiency air filter. ldealComfort' Control Center --The microprocessor control center features state -of -the -art combustion, temperature, and airflow control to maximize comfort while operating at peak efficiency. Combustion control is obtained by taking the inducer motor RPM reading when the medium -heat pressure switch makes. Using this information, the microprocessor maintains a consistent air -to -fuel ratio independent of vent sizing and conditions during all phases of heat. The first cycle after power reset provides 16 minutes of low heat before switching to high heat unless the room thermostat has been satisfied. Subsequent thermostat cycles provide anywhere from 0 to 16 minutes of low or medium heat depending on the length of the previous thermostat cycle. Airflow control is accomplished by the microprocessor and blower motor. The ECM blower motor is configured by the microprocessor to react to changes in the static load on the air delivery system. The ECM blower uses this information to deliver correct airflow independent of variations in system restrictions. (For example, dirty filter or zone damper changes during a cycle.) A special dehumidification function allows direct input from a thermidistat or humidistat. This input adjusts system airflow for greater humidity removal and increased cooling comfort during summer months. Warranty—The Infinity" ICS heat exchangers come with a Limited Warranty for lifetime of original owner in single family residence; 20 years in other residential and commercial applications. Five -year limited warranty on entire furnace. Direct Venting or Optional Ventilated Combustion Air -- -The Infinity" ICS can be installed as a 2 -pipe (Direct Vent) furnace or as an optional ventilated combustion air application. This provides added flexibility to meet diverse installation needs. Electronic Variable -Speed Motors —ECM Motors (Electronically Commutated Motor) provide variable -speed operation to optimize comfort levels in the home year round. They are also more economical to operate than standard motors. Sealed Combustion System— Infmity'" ICS brings in combustion air from outside the fumace, which results in especially quiet operation. Insulation —Foil -faced insulation in heat exchanger section of the casing minimizes heat loss. Insulated Blower Compartment —The acoustical insulation reduces air and motor noise for quiet operation. Monoport Burners —The burners are finely tuned for smooth, quiet combustion and economical operation. Bottom Closure— Factory- installed for side return; easily removable for bottom return. Blower Access Panel Switch — Automatically shuts off 115 -v power to furnace whenever blower access panel is opened. Quality Registration —The Infinity"' ICS is engineered and manufactured under an ISO 9001 registered quality system. Certifications —The Infinity "' ICS, Model 58MVC units are CSA. (A.G.A. and C.G.A.) design certified for use with natural and propane gases. The furnace is factory- shipped for use with natural gas. A C.S.A. listed gas conversion kit is required to convert furnace for use with propane gas. The efficiency is GAMA efficiency rating certified. The Infinity ICS meets California Air Quality Management District emission requirements- 7 FURNACE COMPONENTS 1. Combustion -air intake connection to ensure contaminant- free air (right or left side). 2. Bunter sight glass for viewing burner flame. 3. Burner assembly (inside). Operates with energy - saving inshot burners and Power Heat" igniter for safe, dependable heating. 4. VariPhase" multi -stage redundant valve assembly. Safe and efficient. Features one primary gas control with two internal shutoff valves and a throttling valve. 5. Vent outlet. Uses PVC pipe to carry flue gas from the furnace's combustion system (right or left side). 6. Inducer motor. Pulls hot flue gases through the heat exchangers, maintaining negative pressure for added safety. 7. Blower access panel safety interlock switch. 8. Air filter and retainer (location in furnace may vary). 9. Condensate drain connection. Collects moisture condensed from burned gases for disposal into home drain system. (Location in furnace varies.) 10. Heavy -duty blower. Circulates air across the heat exchangers to transfer heat into the home. 3 A07509 11. Serpentuff" secondary condensing heat exchanger (inside). Wrings out more heat through condensation. Constructed with polypropylene- laminated steel to ensure durability. 12. Primary serpentine heat exchanger (inside). Stretches fuel dollars with the S- shaped heat -flow design. Solid construction of corrosion - resistant aluminized steel means reliability. 13. Furnace control hoard. 14. 3 -amp fuse provides electrical and component protection. 15. Light emitting diode (LED) on furnace control board. Status code light is for diagnosing furnace operation and service requirements. 16. Pressure switches ensure adequate flow of flue gas through furnace and out vent system. 17. Rollout switch (manual reset) to prevent overtemperature. 18. Junction box for 115 -v electrical power supply. (May be located on right or left side) 19. Transformer (24v) behind furnace control board provides low- voltage power to furnace control board and thermostat. PHYSICAL DATA DESCRIPTION 11 UNIT SIZE V 060 -14 080 -14 - 080 -20 100 -20 120 -20 • Direct -Drive Motor Hp (ECM) 1/2 1/2 1 1 1 Motor Full Load Amps 7.7 7.7 12.8 12.8 12.8 RPM (Nominal)- Speeds Variable 250 -1300 Blower Wheel Diameter X Width (in.) 10 X 7 11 X 10 11 X 10 11 X 10 11 X 10 Filter Size (in.) Nominal A (Washable) (1) 16 X 25 X1 (1) 20 X 25X 1 (1) 20 X 25 X1 (1) 20 X 25 X 1 (1) 24 X 25 X1 Shipping Weight (lb) 170 182 1 204 203 234 Limit Control Selectable 90, SPST 120, 150, or 180 4 4 (625 * *) Heating Blower Control (Off Delay) SEC Intervals 5 6 Burners (Monoport) 3 4 -1 Gas Connection Size 1/2 -in. NPT Gas Valve (Redundant) Manufacturer Minimum Inlet Pressure (in. wc) Maximum Inlet Pressure (in. wc) White- Rodgers 4.5 (Natural Gas) 13.6 (Natural Gas) Ignition Device Hot Surface -SiN PERFORMANCE DATA UNIT SIZE 060 -14 080 -1-4 080 -20 100 -20 120 -20 CERTIFIED TEMP RISE RANGE (5-0)---- Low 35 - 65 35 - 65 35 - 65 40 - 70 35 - 65 Medium 50 - 80 50 - 80 50 - 80 50 - 80 50 - 80 -RR- 35 -65 40 -70 35 -65 45 -75 f 45 -75 CERTIFIED EXT STATIC PRESSURE (ESP) Heating Cooling 0.12 0.15 0.15 0.20 0.20 0.50 0.50 0.50 0.50 0.50 AIRFLOWCFM$ Heating Low (470 * *) (620 * *) (605 * *) (760 * *) 890 (1025 * *) 'eating Medium -- Heating Nigh Cooling (7 ax 4 (625 * *) 6 (800 * *) 49• (790 * *) :7 �• (1005 * *) (1260 * *) - - FO-7 3• • MEV *II 14• • {I r r 1375 I`i:rU saf�[•h s ?si•>•f�?= mim= 060 �TIa)• • . re. OUTPUT CAPACITY BTUH* (ICS) Low UpfI15 • •wn ow 2 • • • 30000 �Iri•i o1•i%TiIre ■ : • I onzon: 210•• •Tlr• i 1 •• T'S ill • r•r Medium Upflow 37000 49000 49000 61000 73000 sown 'ow 36000 4•TIVI 490'. 61000 - Ts so 'onzont- 36000 4eirso 4•srt 610rr 73000 High Upflow 56000 74000 74000 94000 112000 Downflow 56000 74000 74000 94000 112000 Ffonzontal 56000 74000 74000 93000 112000 AFUE %* Nonweatherized ICS Upflow 95.0 95.0 95.0 95.0 95.0 Downflow 92.1 92.3 92.3 93.5 93.3 Horizontal 94.0 94.7 94.7 94.8 93.8 INPUT BTUHt Low 24000 32000 32000 40000 48000 Medium 39000 52000 52000 65000 78000 High 60000 80000 80000 100000 120000 * Capacity in accordance with U.S. Government DOE test procedures. t Gas Input ratings are certified for elevations to 2000 it. For elevations above 2000 ft. reduce ratings 2% for each 1000 It above sea level. In Canada, derate the unit 5% for elevations from 2000 to 4500 ft above sea level. # Airflow shown is for bottom only return -air supply with factory- supplied 1--in. washable filter(s). For air delivery above 1800 CFM, see Air Delivery Table for other options. •• Low- and Medium -heat CFM when low /medium heat rise adjustment switch (SW 1 -3) on furnace control is used. 9 • AIR DELIVERY - CFM (BOTTOM RETURN WITII FILTER) Unit Size Operating Mode CFM Airflow External Static External Static Pressure (ESP) Settin g Pressure Flange. 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 060 -14 1'1 Low Heat 410t 0 -0.50 410 410 410 410 405 tt Medium Heat 560* 0 -0.50 545 560 560 560 560 tt High Heat 1070t 0 -1.0 1065 1070 1070 1070 1070 1070 1 1070 x1065 1 1045 1 1015 1 -1/2 -Ton A/C Cooling 525 0 -0.50* 525 525 525 525. 525 ft 2 -Ton NC Cooling 2 -1/2 -Ton A/C Cooling 700 0 -0.50* 700 700 700 700 700 875 0 -1.0* 875 875 575 875 875 875 875 875 860 840 3 -Ton A/C Cooling 1050 0 -1.0 1050 1050 1050 1050 1050 1050 1050 1050 1050 1045 3 -1/2 -Ton A/C Cooling 1225 0 -1.0 1225 1225 1225 1225 1225 1225 1225 1225 1225 1205 Maximum 1400 0 -1.0 1400 1400 1400 1400 1400 1400 1400 1400 1380 1325 080 -14•" tt Low Heat 540* 0 -0.50 540 540 535 525 510 t1' Medium Heat 710* 0 -0.50 • 695 695 685 685 685 1't High Heat 1220t 0 -1.0 1220 1220 1220 1220 1220 1220 [ 1220 1 1220 1 1195 1 1 150 1 -1/2 -Ton NC Cooling 525 0 -0.50$ 515 495 490 475 465 if 2- -Ton NC Cooling 700 0- 0.50$ 685 680 670 665 665 2 -1/2 -ion NC Cooling 875 0 -1.0* 830 840 850 860 860 855 840 830 825 820 3 -Ton A/C Cooling 1050 0 -1.0$ 1050 1050 1050 1050 1050 1045 1040: 1025 1015 1000 3 -1/2 -Ton NC Cooling 1225 0 -1.0f 1225 1225 1225 1225 1225 1225 1325 1225 i 1225 1185 1140 Maximum 1400 0 -t.0$ 1400 1400 1400 1400 1375 1280 1 1235 1190 1145 080 -20x: ft 1't Low Heat 525* 0 -0.50 525 490 475 455 430 Medium Heat 705* 0- 0.50 685 655 660 660 660 High Heat 1470t 0 -1.0 1470 1470 1470 1470 1470 1470 1 1455 1 1450 1 1435 1 1420 1't 2 -Ton NC Cooling 700 0 -0.50* 670 640 635 630 630 11 2 -1/2 -Ton NC Cooling 875 0 -0.50* 870 875 865 865 865 3 -Ton A/C Cooling 1050 0 -1.01- 1050 1045 1040 1045 1045 1050 1050 1050 1045 1040 3 -1/2 -Ton A/C Cooling 1225 0 -1.0* 1225 1225 1225 1225 1225 1225 1225 1225 1225 1225 4 -Ton NC Cooling 1400 0 -1.0k 1330 1345 1360 1375 1380 1380 1380 1370 1365 1355 5 -Ton NC Cooling 1750 0 -1.0 1750 1750 1750 1750 1750 1750 1745 1725 1700 1685 Maximum 2000 0 -1.0 2000 2000 2000 2000 1975 1955 1920 1870 1820 1770 100 -20••• - tt Low Heat 6601' 0 -0.50 660 660 655 655 655 1't Medium Heal High Heat 8901 0 -0.50 875 890 890 890 890 151011 700 0 -1.0 0 -0.50* 1510 700 1510 690 1510 690 1510 690 1510 690 1500 1 1490 1 1480 1 14701 1455 11 2 -Ton A/C Cooling t1' 2 -1/2 -Ton NC Cooling 875 0 -0.50$ 835 845 855 860 865 3 -Ton NC Cooling 1050 0 -1.0$ 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 3 -1/2 -Ton NC Cooling _ 1225 1400 0 -1.0* 1170 1190 1205 1220 1225 1225 1225 1225 1225 1225 4 -fon A/C Cooling 0 -1.0* 1400 1400 1400 1400 1400 1400 1400 1400 1400 1375 5 -Ton NC Cooling 1750 0 -1.0 1735 1740 1735 1735 1725 1720 1710 1695 1680 1660 Maximum 2000 0 -1.0 1995 1985 1980 1965 1950 1935 1910 1885 1860 1815 120 -20 Low Heat 890f 0 -1.0 890 890 890 880 885 890 885 885 875 860 Medium Heat 1130t 0 -1.0 1095 1110 1120 1130 1125 1130 1130 1115 1860 1110 1105 High Heat 1900t 0 -1.0 1900 1900 1900 1900 1900 1885 1875 1840 1815 1't 2 -Ton NC Cooling 700 0 -0.50$ 700 700 700 700 695 1 t 2 -1/2 =Ton A/C Cooling 875 0 -0.50$ 870 875 875 865 870 3 -Ton NC Cooling 3 -1/2 -Ton A/C Cooling 1050 1225 0 - -1.0k 1025 1035 1045 1050 1050 1050 1050 1050 1040 1025 0 -1.0* 1210 1210 1210 1225 1225 1225 1225 1225 1225 1225 4 Ton NC Cooling 1400 0 -1.0# 1385 1400 1400 1400 1400 1400 1400 1395 1375 1370 5 -Ton A/C Cooling 1750 0 -1.0* 1745 1730 1735 1735 1740 1735 1730 1725 1710 1685 6 -Ton NC Cooling 2100 0 -1.0 2100 2100 2080 2065 2060 2045 2030 2000 1960 1895 Maximum _ 2100 0 -1.0 L21013 2100 2080 2065 2060 2045 2030 2000 1960 1895 Actual external static prossure (ESP) can 00 de ermine .. y using the fan laws (CFM proportional to ESP); such as a system with 1750 CFM at 0.5 ESP would operate at high- heating airflow 011470 CFM at 0.35 ESP medium - heating airflow of 706 CFM at 0.08 ESP and low- heating airflow of 525 CFM at 0.05 ESP. tAll heating CFM's are when low /medium heat rise adjustment switch (SW1 -3) and comfort/efficiency adjustment switch (SW1 -4) are OFF. *Ductwork must be sized for high- healing CFM within the operational range of ESP. 1't Operation within the blank areas of the chart Is not recommended because high -heat operation will be above 1.0 ESP. •••AII airflows on 21" casing size furnaces are 5% less on side return only installations. Combustion -air Pipe for Non - Direct (1 -Pipe) Vent Application (Sizes 040 through 120 only) 10 120 - 100- 1 /\kk §{{§ 24 -1 /2 /EE 21 /53 21 /53; 21 /53: 17 =1/27 I". . m § en z CO G 2 $ 6 J 1/58 / 1%49: / 1 4Y § § { \/ 16 / 406.4 %»a m A. 4) 6) 6) 1 § � R, R, mm/ (k0 / \ -a° /§/ '7(I](§2E7 /[[2009& -E a $ ) / / \§/ co JaI %§ '° /#c2 =72sEs \ I 0 01 01 \(\{ {)]/ 3 -, ° 0 >< 01 sm� -e ƒ / %%f § / / <b - § ( C»; ;£ al `00E o0- o §_=n- q \ P o , gs M =7E °- _S§E // CD § }\ (k 2 02 k - *§ \[k mm \ $§2 1,-401 �M 7 im k/§ \ \j Z1 F. -- 131NI 3GIS \ Pa \/ j + M. F,_ - th th DIMENSIONS (IN. / MM) MEDIA FILTER CABINET A FURNACE CASING WIDTH FURNACE IN DOWNFLOW APPLICATION PLENUM OPENING* FLOOR OPENING 16 / 406.4 HOLE NO. FOR WIDTH ADJUSTMENT A 21 533.4 B C 24 / 609.6 D 24/ 609.6 - 17-1/2 / 444.5 Furnace with or without Cased Coil Assembly or Coil Box 15-1/8 / 384 2 19 / 482.6 16-3/4 425.5 / 20 -3/8 517.5 / 3 21 / 533.4 Furnace with or without Cased Coil Assembly or Coil Box 18 -5/8 / 396 4 19 / 482.6 20-1/4 514.4 / 20 -3/8 517.5 / 2 24-1/2 / 622.3 Fumace with or without Cased Coil Assembly or Coil Box 22 -78 / 562.0 19 / 482.6 23 -3/4 603.3 / 20 -318 517.5 / 1 utd oe constructed 1 /4 -in. smaller in width and depth than the plenum dimensions shown above. 1 Va" TYP PLENUM OPENING FACTORY- SUPPUED FIELD- INSTALLED INSULATION A97427 Assembled 23541" 23 3/8" Furnace Side 23 Screw Slots LOCATING TAB Downflow Subbase A Disassembled 25%" A88207 24 i4 Opening with Flanges Rent Opening .y Duct Side A07803 DIMENSIONS (IN. / MM) MEDIA FILTER CABINET A B SHIPPED WITH SIZES 16 / 406.4 17 / 432.8 16 / 406.4 060 -14 20 / 508.0 21 533.4 20 / 508 080 -14, 080 -20 24 / 609.6 25 / 635.0 24/ 609.6 - 100 - 20 Media Filter Cabinet 13 ELECTRICAL DATA UNIT SIZE 060 -14 080 -14 I 080 -20 100 -20 J 120 -20 UNITVOLTS — HERTZ — PHASE 115 -60 -1 OPERATING VOLTAGE RANGE (Mtn — Max)* 104 — 127 MAXIMUM UNIT AMPS 8.96 8.96 14.06 14.06 14.06 MINIMUM WIRE SIZE 14 14 12 12 12 31 - MAXIMUM WIRE LENGTH (Ft)$ 30 30 31 31 MAXIMUM FUSE OR CKT BKR (Amps) ** 15 15 20 20 20 TRANSFORMER (24v) 40va EXTERNAL CONTROL POWER AVAILABLE Heating 18va Cooling 34va *Permissible limits of the voltage range at which the unit wdl operate satisfactorily. Length shown is as measured one way along wire path between unit and service panel for maximum 2% voltage drop. ''Time —delay type is recommended. FIVE WIRE THREE -WIRE HEATING - ONLY NOTE 2 1 -STAGE 115 -VOLT FIELD - SUPPLIED FUSED DISCONNECT JUNCTION BOX CONTROL BOX 24 -VOLT TERMINAL BLOCK FURNACE I I I ! I I ! L__I I I I I ! 1 I I I I I NOTE 1 I I I - - -- FIELD 24 -VOLT WIRING - - -- FIELD 115 -, 208/230 -, 460 -VOLT WIRING ----- FACTORY 24 -VOLT WIRING — FACTORY 115 -VOLT WIRING THERMOSTAT TERMINALS FIELD- SUPPLIED FUSED DISCONNECT CONDENSING UNIT 208/230- OR 460 -VOLT -- THREE PHASE 1- -1 208/230 - IVOLT -- SINGLE -- PHASE NOTES: 1. Connect Y/Y2- terminal as shown for proper operation. 2. Some thermostats require a terminal connection as shown. 3. If any of the original wire, as supplied, must be replaced, use same type or equivalent wire. Typical Wiring Schematic 14 A95238 A95236 Maximum Allowable Pipe Length (Ft / M) 15 Direct Vent (2 -Pipe Only) NUMBER OF 90° ELBOWS UNIT SIZE (BTUH) ALTITUDE Termination Type Pipe Dia (IN.)* 1 2 3 4 5 6 60,000 O to 2000 2 Pipe or 2-In. Concentric 1 -1/2 50/15.2 45/13.7 40/12.9 35/10.7 30/9.1 25/7.6 2 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 80,000 2 Pipe or2 -In. Concentric 1 -1/2 30/9.14 25/7.6 20/6.1 15/4.6 10/3.0 5/1.5 2 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 100,000 2 Pipe or 2 -In. Concentric 2 45 / 13.7 40 / 12.9 35 / 10.7 30 / 9.1 25 / 7.6 20 / 6.1 2-1/2 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 120,000 2 Pipe or 3 -In. Concentric 2-1/2 one disk 10 / 3.0 NA NA NA NA NA 3 one disk 35 / 10.7 30 / 9.1 15 / 4.8 NA NA NA 3cnediskt 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 UNIT SIZE (BTUH). ALTITUDE Termination Type Pipe Dia (IN.)* NUMBER OF 90° ELBOWS 1 2 3 4 5 6 60,000 2001 to 3000 2 Pipe or 2-In. Concentric 1 -1/2 45/13.7 40/12.9 35/10.7 30/9.14 25/7.6 20/6.1 2 70/ 21.3 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 80,000 2Pipeor2 -In. Concentric 1 -1/2 26/7.9 21/6.4 16/4.9 11/3.4 6/1.8 NA 2 70/21.3 70/21.3 70 /21.3 70/21.3 70/21.3 70/21.3 100,000 120,000 2Pipeor2 -In. Concentric 2 40/12.2 35/10.7 30/9.1 25/7.6 20/6.1 15/4.6 2 -1/2 70/21.3 70/21.3 70/21.3 70 /21.3 70/21.3 70/21.3 2 Pipe or 3 -In. Concentric 3 one disk 31 / 9.4 26/ 7.9 12 / 3.7 NA NA NA 3 one diskt 63 / 19.2 62 / 18.9 62 / 18.9 61 / 18.6 61 / 18.6 61 / 18.6 UNIT SIZE (BTUH) 60,000 ALTITUDE 3001 to 4000 Termination Type 2 Pipe or 2-In. Concentric Pipe Dia (IN.)* 1-1/2 NUMBER OF 90° ELBOWS 1 2 3 4 5 6 42/12.8 37/11.2 32/9.8 27/8.2 22/6.7 17/5.2 2 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 80,000 2 Pipe or 2 -In. Concentric 1 -1/2 25/7.6 20/6.1 15/4.6 10/3.0 5 /1.5 NA 2 70/21_3 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 100,000 2 Pipe or2 -In. Concentric 2 38/11.6 33/10.1 28/8.5 23/7.0 18/5.5 13/4.0 2 -1/2 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 120,000 2 Pipe or 3 -In. Concentric 3 one disk 29 / 8.8 24 / 7.3 10 / 3.0 NA NA NA 3 one diskt 59 / 18.0 59 / 18.0 58 / 17.8 57 / 17.4 57 / 17.4 56 / 17.0 UNIT SIZE (BTUH) ALTITUDE Termination Type 2Pipeor2 -In. Concentric Pipe Dia (IN.)* 1 -1/2 NUMBER OF 90° ELBOWS 1 40/12.2 2 35/10.7 3 30/9.1 4 25/7.6 5 20/6.1 6 15/9.6 60,000 400110 5000* 2 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 80,000 2 Pipe or 2-In. Concentric 1-1/2 23 / 7.0 18 / 5.5 13 / 4.0 8 / 2.4 NA NA 2 70/21.3 70/213 70/213 70 / 21.3 70/213 68/20.7 100,000 2 Pipe or 2-In. Concentric 2 36 / 11.0 31 / 9.4 26 / 7.9 21 / 6.4 16/4.8 11 / 3.4 2 -1/2 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 120,000 2 Pipe or 3-In. Concentric 3 one diskt 56 / 17.1 55 / 16.8 54 / 16.5 53 / 6.2 52 / 15.8 52 / 15.8 UNIT SIZE (BTUH) ALTITUDE Termination Type Pipe Dla (IN.)* NUMBER OF 90° ELBOWS 1 2 3 4 5 6 60,000 5001 to 6000# 2 Pipe or 2-In. Concentric 1 -1/2 37/11.3 32/9.8 27/8.2 22/6.7 17/5.2 12/3.7 2 70/ 21.3 70/21.3 70/213 70/21.3 70/21.3 70/21.3 80,000 2Pipeor2 -In. Concentric 1 -1/2 22/6.7 17/5.2 12/3.7 7/2.1 NA NA 2 70/213 70/21.3 70/21.3 70/ 21.3 68/20.7 63/19.2 100,000 2 Pipe or2 -In. Concentric 2 33/10 28/8.5 23/7.0 18/5.5 13/4.0 8/2.4 2-1/2 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 70/21.3 120,000 2 Pipe or 3- In. Concentric 3 one diskt 53 / 16.2 52 / 15.8 50 / 15.2 49 / 14.9 48 / 14.6 47 / 14.3 15 Maximum Allowable Pipe Length (Ft / M) (Continued) ALTITUDE UNIT SIZE (BTUH) Direct Vent (2 -Pipe Only) NUMBER OF 90° ELBOWS Termination Type Pipe Dia (IN.)* 1 2 3 4 5 6 6001 to 7000t 60,000 2 Pipe or2 -In. Concentric 1 -1/2 35/10.7 30/9.1 25/7.6 20/6.1 1514.6 10/3.0 2 70/21.3 70/21.3 68/20.7 67/20.4 66/20.11 64/19.5 80,000 2 Pipe or2 -In. Concentric 1 -1/2 20/6 -1 15/4.6 10/3.0 5/1.5 NA NA 2 70 / 21.3 70 / 2.1.3 68 / 20.7 67 / 20.4 62 / 18.9 571 17.4 100,000 2 Pipe or 2- In. Concentric 2 31 / 9.4 26 / 7.9 21 / 6.4 16 / 4.9 11 / 3.4 6 / 1.8 2-1/2 70/21.3 70/21.3 68/20.7 67/20.4 66/20.1 64/19.5 120,000 2 Pipe or 3 In. Concentric 3 one diskt 49 / 14.9 48 / 14.6 47 / 14.3 45 / 13.7 44 / 13.4 43 / 13.1 ALTITUDE UNIT SIZE (BTUH) Termination Type Pipe Dia (IN.)* NUMBER OF 90° ELBOWS 1 2 3 4 5 6 7001 to 8000# 60,000 2Pipeor2 -In. Concentric 1 -1/2 32/9.8 27/8.2 22/6.7 17/5.2 12/3.7 7/2.1 2 66 /20.1 65 / 19.8 63 / 19.2 62 / 18.9 60 / 18.3 59 / 18.0 80,000 2 Pipe or2 -In. Concentric 1 -1/2 18/5.5 13/4.0 8/2.4 NA _ NA NA 2 66 / 20.1 65 / 19.8 63 / 19.2 62 / 18.9 57 / 17.4 52 / 15.8 100,000 2 Pipe or2 -In. Concentric 2 29/8.8 24/7.3 19/5.8 14/4.3 9/2.7 NA 2 -1/2 66/20.1 65/19.8 63/19.2 62/18.9 60/18.3 59/18 120,000 2 Pipe or 3 -In. Concentric 3 one diskt Pipe Dia (IN.)* 46 / 14.0 1 44 / 13.4 NUMBER 43 / 13.1 41 / 12.5 40 / 12.2 38 / 11.6 ALTITUDE 8001 to 9000# UNIT SIZE (BTUH) Termination Type OF 90° ELBOWS 2 3 4 5 6 5/1.5 53 / 16.2 60,000 2 Pipe or2 -In. Concentric 1 -1/2 30/9.1 25/7.6 20/6.1 15/4.6 10 / 3.0 55 / 16.8 2 62 / 18.9 60 / 17.8 58 / 17.7 56 / 17.1 80,000 2Pipeor2 -In. Concentric 1 -1/2 17/5.2 12/3.1 7/2.1 -NA NA NA 2 62 / 18.9 60 / 18.3 58 / 17.7 56 / 17.1 51 / 15.5 46 / 14.0 100.000 2 Pipe or 2 -In. Concentric 2 27/8.2 22/6.7 17/5.2 12/3.7 7/2.1 NA 2-1/2 62 / 18.9 60 / 18.3 58 / 17.7 56 / 17.1 55 / 16.8 53 / 16.2 120,000 2 Pipe or 3 -In. Concentric 3 one disk$ 43 / 13.1 41 / 12.5 39 /11.9 37 / 11.3 35 / 10.7 34 / 10.4 ALTITUDE UNIT SIZE (BTUH) Termination Type Pipe Dia (IN.)* NUMBER OF 90° ELBOWS 1 2 3 4 5 6 9001 to 10000# 60,000 2Pipeor2 -In. Concentric 1 -1/2 27/8.2 22/6.7 17/5.2 12/3.7 7/2.1 NA 2 57 / 17.4 55 / 16.8 53 / 16.2 51 / 15.5 49 / 14.9 47 / 14.3 80,000 100,000 2 Pipe or 2 -In. Concentric 2 Pipe-or 2 -In. Concentric 1 - -1/2 15 /4.6 10 / 3.0 5 / 1.5 NA NA NA 2 2 2 -1/2 57 / 17.4 24/7.3 57 / 17.4 55 / 16.8 53 / 16.2 51 / 15.5 46 / 14.0 41 / 12.5 19/5.8 14/4.3 9/2.7 NA NA 55 / 16.8 53 / 16.2 51 / 15.5 491 14.9 47 / 14.3 120,000 2 Pipe or 3- In. Concentric 3 one disk# 39/ 11.9 37 / 11.3 35 / 10.7 33 / 10.1 31 / 9.5 29 / 8.8 Dsk usage- Untess otherwise stated, use perforated dsk assembly (factory- supplied in loose parts bag). t Wide radius elbow. $ Vent sizing for Canadian Installations over 4500 tt (1370m) above sea level are subject to acceptance by the local authorities having jurisdiction. NA -Not Allowed; pressure switch will not make. NOTES: 1. Do not use pipe size greater than those specified in table or incomplete combustion, flame disturbance, or flame sense lockout may occur. 2. Size both the combustion -air and vent pipe independently, determine the smallest diameter allowed by the table for each pipe. then use the larger diameter for both pipes. 3. Assume two 45° elbows equal one 90° elbow. Long radius elbows are desirable and may be required In some cases. 4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count. 5. The minimum pipe length is 5 k for all applications. Maximum Allowable Exposed Vent Pipe Length (Ft / M) with Insulation in Winter Design Temperature Ambient* UNIT SIZE IV 1 • B 1 TEMPERATURE f .V r 1 r • • 1 AMETER (IN.) tL W, - 1 1 • ' aE 0 3/8 1/2 3/4 1 060 -14 209- 1 -6.7 °C 2 30/9.1 55/16.8 61/18.6 70/21.3 70/21.3 00F/-17.8°C 2 16/4.9 33/10.1 38/11.6 46 /14.0 53/16.2 - 20 °F /- 28.9 °C 2 9/2.7 23/7.0 26/7.9 33/10.1 38/11.6 70/21.3 090 -14 080 -20 200F/-6.7°C 2 37/11.2 65/19.8 70/21.4 70/21.3 0 °F /- 17.8 °C 2 ' 20/6.1 39/11.9 45/13.7 55/16.8 63/19.2 - 20 °F /- 28.9 °C 11/3.4 27/8.3 31/9.4 39/11.9 45/13.7 100 -20 200F/-6.7°C 2 -1/2 41/12.5 70/21.3 70/21.3 70/21.3 70/21.3 0 °F/- 17.8 °C 2 -1/2 21/6.4 42/12.8 48/1-4.6 59/18.0 68/20.7 - 20 °F /- 28.9 °C 2 -1/2 11/3.4 28/8.5 33/f0.1 41/12.5 49/14.9 120 -20 20 °F / -6.7 °C 3 3- 3 49/14.9 26/7.9 15/4.6 70/21.3 51 /15.5 35/10.7 70/21.3 58/17.7 40/12.2 70/21.3 70/21.3 50/15.2 70/21.3 70721.3 39718.0 0 °F /- 17.8 °C - 20'F/- 28.9'C Pipe length (ft/m) spec itied for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe length as specified in Table ?. j Insulation thickness based on 8 value of 3.5 per in. 16 INSTALLATION • This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3.C1, accept 140 size furnaces are only approved for attitudes 0 - 7.000 R 0- 2.135m)_ • An accessory id, supplied by the manufacturer, shall be used to convert to gas use a be required for some natural gas applications • 1 his ftur ace is for i vtstaUation in a building dng constructed on site This may be installed in a manufactured (motile) home when stated on rating plate and using factory authorized kit. • This frrace may he instated on combustible leering in alcove a doset at Minimum Inches Clearance To Combustible Construction as described below. • This furnace requires a social venting system Refer to the installation instructions fa parts list and method of installation. This furnace is for use with schedule-40 PVC, PVC-Dvw. (3 VC, a ARS.DVW pane, and mat not be vented In common with other gas -rued aretances Construction I Y0 gh wMcm vent/air intake pipes may be installed is rrxcdmm 24 inches (600 ran). minimum 3/4 Inches (19 mm) thickness (i during roofirig materials). • Cette fourrssse a air prise est equipee pots utilisation avec gaz naturel et altitudes ccnprises entre 0 -3,050m (0. 10.000 pi), excepte queles tournases de 140 talte sent pour altitudes comprises entre 0 - Z,135rn (0 - 7,000 p). • Utiliser tone trousse de conversion, founre par le fabricant, pour passer au gaz propene ou pour certanes Installations au gaz nature'. • Cette feurrtalse a air ease est pour installation a I"Interieur dans un balirnent constant sur place. Cette fournaise a alr pulse peat titre insiallee dans une mason prefatxiques (raison mobile) si presaft par la plaque signaietiique et si Ion utilise une trausse spedfiee par le fabricant • Cette fournaise peut etre inatalee sir un plan der combustible darns un enfaeerrieit ou to placard en observant les Degagement Minimum En Pouces Avec Elements De Construction Combustibles. • Cette faurnaise necessite un systnme dEVaaiation special. La rrhethode d"instalation et la Este des pieces necessainas figment darts les irtttlatiors d(nstallation. Cette fou maise dott s'Lpliser avec is ttryauterie des nornendatures 40 PVC, PVC-13W, CPVC, ou ABSDNV et elle ne peat pas @re ve ttilee =Ointment o "aide's apparels A �z paissett de (a construction au travels de !equate it est possible de faire passer les tryout Caeratian (admssian/evecuation): 24 maodrnrn, 3/4 po (19 con) minimum (y cornetts to toit re). For upflow and dovrdlow appf ations, furnace mat be installed level, a pitched witin 1/2' of level. For a horizontal application, the furnace must be pitched minimum 1/4° to maximum of 1/2' forward for proper drainage. See Installation Manual for IMPORTANT unit support details on horizontal applications Par des applications de flux ascendant et desoomcird, la tournaise dolt are I nstallde de riveau ou inclines a pas pus de 1/2' du riveau. Pour tape application horizadale, la foumaise dot cue indinee entre mirerrum 1/4' eel maximum 1/2° du niveau par le drainage approprie. En loss dinstailation en position horizordale, txxs4ter les rerseignemes is IMPCRTANTS sur le support dares le manual dinstalation. MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION ALL POSITIONS: * Mimimrn front deaance for service 30 inches (762rmn). DOWNFLOW POSITIONS: t For installation on combustible floors only when installed on special base No. KGAS80201ALL, Coil Assembly, Part No. Cab or CK5, or Cod Casing, Part No. KCAKC. HORIZONTAL POSIONS: Line contact is permissible only between lines formed by Intersections of top and two sides of f macejacket, and (wilding joists, studs, or taming. Clearance shown is for air inlet and air outlet ends. O 120 size furnace requires 1 inch bottom clearance to combustible materials. DEGAGEMENT MINIMUM EN POUCES AVEC ELEMENTS DE CONSTRUCTION COMBUSTIBLES POUR TOUS LES POSmONS: ht Degagement avant minimum de 762mm (30 po) pour ("entretien. POUR LA POSITION COURANT DESCENDANT: t Pour ('installation sur le planchet combustible seulement quand on utilise la base spectate, piece n° KGASB0201AL1, I "ensemdule serpentin, piece n° CD5 ou CK5, ou le carter de serpentin, piece n° KCAKC. POUR LA POSmON HORRONTALE: Le canted nest perrris giientre les Wes farrdes par les intersections du dessus et des deuxo5tes de la chemise de la fotmaise, et des soluves, des mordants ou de la c arpente du batiment. La distance indiquee cencemne I•extremlte du tuyau darrivee d'air et I"extremite du tuyau do sortie dair. 0 Pour les foumaises de 120 talle, 1 po (25mm) degagement des materiattt combustibles estrequis au- dessous. § LEVEL (0')T0 12• MAX 1L„ ' T UPFLOW OR DOWNFLOW MIN 1/4' TO 1/2' MAX HORIZONTAL This furnace is apprwad for UPFLOLN, DOVVNFLOW and HOFdZONTAL installations. Cede fa rr aise est appeake pour rinslahation HORIZONfALE et la drab/ion d'air VERS LE HAUT et VIERS LE BAS. 328068-201 Rev.A Clearance to Combustibles 17 A07823 COMBUSTION AIR PIPE OUTDOOR UNIT NC COIL 1•111111i1 Immo 001 10 1 40- HUMIDIFIEI-I 1/01 IL 0 AIRFLOW ELECTRONIC AIR CLEANER ELECTRONIC AIR CLEANER FRONT OF FURNACE Upflow Application VENT GAS -FIRED WATER HEATER COMBUSTION AIR (DIRECT VENT/ 2 PIPE APPLICATION OUTDOOR UNIT NC COIL FRONT OF FURNACE ( > AIRFLOW Downflow Application 18 A06511 A07799 VENT PIPE 111 1 COMBUST ON-AIR PIPE DIRECT VENT /2 -PIPE APPLICATION) TION VENTI TEO COM USTION R APPL ! ATION ELECTRONIC AIR CLEANER FRONT OF FURNACE FURNACE CONDENSATE DRAIN REFRIGERATION PIPING AIRFLOW AIR CONDITIONING COIL Attic - Horizontal Application OPTIONAL VENTILATED COMBUSTION AIR INTAKE COMBUSTION- AIR PIPE (DIRECT VENT /2 -PIPE APPLICATION) VENT PIPE REFRIGERATION PIPING AIR CONDITIONING COIL JAIRFLOW FURNACE CONDENSATE — DRAIN FRONT OF FURNACE Crawlspace — Horizontal Application 19 ELECTRONIC AIR CLEANER A07800 A07801 GUIDE SPECIFICATIONS General System Description Furnish a 4 -way multipoise gas -fired condensing furnace for use with natural gas or propane (factory- authorized conversion kit required for propane); furnish cold air return plenum; furnish external media cabinet for use with accessory media filter or standard filter. Quality Assurance Unit will be designed, tested and constructed to the current ANSI Z 21.47 /CSA 2.3 design standard for gas -fired central furnaces. Unit will be third party certified by CSA to the current ANSI Z 21.47 /CSA 2.3 design standard for gas -fired central furnaces. Unit will carry the CSA Blue Star and Blue Flame® labels. Unit efficiency testing will be performed per the current DOE test procedure as listed in the Federal Register. Unit will be certified for capacity and efficiency and listed in the latest GAMA Consumer's Directory of Certified Efficiency Ratings. Unit will carry the current Federal Trade Commission Energy Guide efficiency label. Delivery, Storage. and Handling Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations. Warranty (for inclusion by specifying engineer) U.S. and Canada only. Warranty certificate available upon request. Equipment Blower Wheel and ECM Blower Motor Galvanized blower wheel shall be centrifugal type, statically and dynamically balanced. Blower motor of ECM type shall be permanently lubricated with sealed ball bearings, of hp, and have infinitely variable speed from 250 -1300 RPM operating only when 24 -VAC motor inputs are provided. Blower motor shall he direct drive and soft mounted to the blower scroll to reduce vibration transmission. Filters Furnace shall have reusable - -type filters. Filter shall be in. (X) in. An accessory highly efficient Media Filter is available as an option. Media Filter. Casino, Casing shall be of .030 in. thickness minimum, pre- painted galvanized steel. Copyright 2007 Carder Corp. • 7310 W. Morris St • Indianapolis, IN 46231 Infinity ICS Multi - Stage/Variable Speed Isis Furnace ECM Inducer Motor ECM Inducer motor shall be variable speed design, soft mounted to assembly to reduce vibration transmission. Primary Heat Exchangers Primary heat exchangers shall be 3 -Pass 20 gauge corrosion - resistant aluminized steel of fold- and -crimp sectional design and applied operating under negative pressure. Secondary Heat Exchangers Secondary heat exchangers shall be of a flow - through design having a patented interior laminate coating of polypropylene for greater corrosion resistance with fold - and -crimp design and applied operating under negative pressure. Controls Controls shall include a micro- processor -based integrated electronic control board with at least 16 service troubleshooting codes displayed via diagnostic flashing LED light on the control, a self -test feature that checks all major functions of the furnace, and a replaceable automotive -type circuit protection fuse. Multiple operational settings available, including separate blower speeds for low heat, medium heat, high heat, low cooling, high cooling and continuous fan. Continuous fan speed may be adjusted from the thermostat. Cooling airflow will be selectable between 350 or 400 CFM per ton of air conditioning. Features will also include temporary reduced airflow in the cooling mode for improved dehumidification when an Infinity Control or Thermidistat is selected as the thermostat. Operating Characteristics Heating capacity shall he Btuh input; Btuh output capacity. Fuel Gas Efficiency shall be 92.1 to 95% AFUE. Air delivery shall be cfnt minimum at 0.50 in. wc. external static pressure. Dimensions shall be: depth in.; width in.; height in. (casing only). Height shall be in. with A/C coil and in. overall with plenum. Electrical Requirements Electrical supply shall be 115 volts, 60 Hz, single -phase (nominal). Minimum wire size shall be AWG; maximum fuse size of HACR -type designated circuit breaker shall he amps. Special Features Refer to section of the product data identifying accessories and descriptions for specific features and available enhancements. Printed in U.S.A. Edition Date: 08/07 Catalog No: 58MVC -1 PD Manufacturer reserves the right to change, et any lime, specifications end designs without notice and without obligations. Replaces: NEW 20 • ',PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG08 -258 DATE: 09 -24 -08 PROJECT NAME: VALLEY VIEW SEWER DISTRICT SITE ADDRESS: 14816 MILITARY RD S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: BuildL g' Division 3.4 Public Works f7H'1� ►CAI_ �r Fire Prevention Structural Planning Division ❑ Permit Coordinator n r^ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete u DUE DATE: 09-25-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS R TING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 1 0-23-08 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Untitled Page 0 • General /Specialty Contractor A business registered as a construction contractor with L8i to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company BEISLEY INC 3602755783 PO BOX 2355 BELFAIR WA 98528 MASON CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License 601846685 ACTIVE BEISLI *027LC CONSTRUCTION CONTRACTOR 6/3/1998 10/1/2009 BILLBC *100JR Next License AERLIHL947M7 Associated License Specialty 1 GENERAL Specialty 2 UNUSED Business Owner Information Name Role Effective Date Expiration Date BEISLEY, WILLIAM J Cancel Date 01/01/1980 Bond Amount BEISLEY, PAULA V 4 01/01/1980 08774975 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 FIDELITY it DEP CO OF THE WEST 08774975 08/29/2008 Until Cancelled $12,000.0006/18 /2008 3 EMPLOYERS MUTUAL CAS CO 5271645 08/29/2001 Until Cancelled 08/29/2008 $12,000.0008/27 /2001 2 DEVELOPERS SURETY & INDEM CO 512752C 12/29/2000 Until Cancelled 07/21/2002 $6,000.00 06/07/2002 1 DEVELOPERS INS CO 512752C 06/03/199812/29 /2000 $6,000.00 Insurance Information Page 1 of 2 Insurance Company Name policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 7 CONTINENTAL WESTERN GROUP CWP2710167 .08/29/200708/29 /2009 $1,000,000.0008 /05/2008 OHIO CAS INS https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= BEISLI* 027LC 10/09/2008