Loading...
HomeMy WebLinkAboutPermit PG08-259 - BEST BUYBEST BUY 17364 SOUTHCENTER PY , G08 -259 Parcel No.: 2623049079 Address: Suite No: Cityllif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 17364 SOUTHCENTER PY TUKW Permit Number: Issue Date: Permit Expires On: PG08 -259 09/25/2008 03/24/2009 Tenant: Name: BEST BUY Address: 17364 SOUTHCENTER PY , TUKWILA WA Owner: Name: KIR TUCKWILA 050 LLC/KIMCO Phone: Address: PROPERTY TAX DEPARTMEMT , 3333 NEW HYDE PK RD STE 100 Contact Person: Name: MIKE CONOVER Address: 14111 NE 24 ST , BELLEVUE WA Contractor: Name: BELLEVUE PLBG /HTG INC Address: 14111 NE 24 ST , BELLEVUE WA Contractor License No: BELLEPH288NU Phone: 425 - 641 -4222 Phone: 425 - 641 -4222 Expiration Date: 08/04/2010 DESCRIPTION OF WORK: CONDENSATION AND WATER LINE FOR HUMIDIFIER Value of Plumbing /Gas Piping: Fees Collected: $5,635.00 $92.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -259 Printed: 09 -25 -2008 City of'Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -259 Issue Date: 09/25/2008 Permit Expires On: 03/24/2009 Permit Center Authorized Signature: Date: { ` )—S -01a I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this construction or t Signature: does not • resume to giyy authori an a work. I am • uthhorized t • to violate or cancel the provisions of any other state or local laws regulating and obtain this plumbing /gas piping permit. Print Name: Date: og This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -259 Printed: 09 -25 -2008 Parcel No.: 2623049079 Address: Suite No: Tenant: BEST BUY 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17364 SOUTHCENTER PY TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -259 ISSUED 09/25/2008 09/25/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be-protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -259 Printed: 09 -25 -2008 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give construction or the pe e . ance of P ork. Signature: Print Name: thority to violate or cancel the provision of any other work or local laws regulating /— )6.— Cg Date: doc: Cond -10/06 PG08 -259 Printed: 09 -25 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:/lwww.ci.tukwila.wa.us ',.Mechanical Permit No. Numbing/Gas P6r*iti:NO: 4•0:. Public Works . „ Project No. • • (For office Use Only). : . Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.: 2/02-30"1— 107 et Site Address: 1136+ 01)"./41Ceiti+e■ p Suite Number: Floor: Tenant Name: 1c'tc---r-51— --IS■Ati Property Owners Name: Mailing Address: New Tenant: LJ Yes No City State Zip WhO:domntdetWhen your Perinii is ready to,be,issUed Name: 41-xevri Mailing Address: ,t/6. Day Telephone: City State State Zip E-Mail Address: Fax Number: 5/,2C - 611/SC/3 INFORMATION _ (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 7-45 6,1t- Mailing Address: 47/g 3 tO3 t2 Contact Person: E-Mail Address: Contractor Registration Number: Nedgfikiti City Day Telephone: Fax Number: Expiration Date: State — All plans,mustbe Wet stamped by Architect of d ..ARCHITECLOF RECORD s • • , ecor Company Name: Mailing Address: City Contact Person: Day Telephone: E-Mail Address: Fax Number: State Zip EgGINEER. OF: REC :.R1) — Alhplans mnstbe wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E-Mail Address: Fax Number: State Zip Q \Applications\Forms-Applications On UneO-2006 Peimit Application.doc Revised: 9-2006 bh Page 1 of 6 GAS PIPING °`PE. _ T INFORMATION - 206- 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: /Q.da / 4 d(14, Mailing Address: / Y1/1 Nr ,2Y Contact Person: M0 e LC» OPitJ E -Mail Address: �A Contractor Registration Number: bhtic. r City Day Telephone: Fax Number: Ltr,4- ODO7 State Zip 4/26'-4 Yi -V22-2- y-ZS i/54118-? Expiration Date: -J NO Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: 4FixtureType: Qty ;Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Q:Wpplications\Fonns- Applications On Line \3-2006 - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 MI; APPLICATION' ES — Applicable to all permits in this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW R OR AUTAORIZED AGENT: Print Name: Fd/1% - Dc ulitiki,i" Mailing Address: / Y/1/ Air I r c Signature: Date: 9V-Q-/Of Day Telephone: City State Zip Date Application Accepted: Date Application Expires: Staff Initials: Q:\Applications\Forms- Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049079 Permit Number: PGO8 -259 Address: 17364 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 09/25/2008 Applicant: BEST BUY Issue Date: Receipt No.: R08 -03363 Initials: WER User ID: 1655 Payment Amount: $92.00 Payment Date: 09/25/2008 03:13 PM Balance: $0.00 Payee: BELLEVUE PLUMBING TRANSACTION LIST: Type Method Descriptio Amount Payment Check 31129 92.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.0 92.00 Total: $92.00 7)3 :T/2-.7 ' "71�° 71•-.i° 92 v y .ice doc: Receiot -06 Printed: 09 -25 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit (206)431 -3670 Prod t: Type of Inspection: Address: 1-7 31,ci qemi-tiftdati Date Called: P Special Instructions: Datewanted: a Requester: Phone No: 14Approved per applicable codes. El Corrections required prior to approval. COMMENTS: V'?..j. ilk erAft 5?)i Insp t r: Date: /b -' -- $61.00 REINSPECTION FE ' EQUIRED Prior to inspection, fee must be pa)d at 6300 Southcenter Bl , ., Suite 00. Call to schedule reinspection. 'Receipt No.: IDate: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 INSPECTION RECORD Retain a copy with permit PER IT NO. Pro e VV �7 LL/ Type of Inaspectio : r- — 1��1 <�.4, b Idle J I tht_th 6 l Date Called: Special Instructions: Da a Wanted: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: (tD IA- x0-6-4-, - t 9 a a s V—. 0 REINSPEDTION ffEE REQUIRED. pal . at 6300 Southcenter Blvd., Suite 10 (Date/ 0_1 d for to inspection, fee must be Call to schedule reinspection. R -' .t No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proj t: Type of Inspection: /. Address: / -736t( ?a/f4ifrAike,021 Date Called: Special Instructions: Date Wanted: 2 �! - /7 /J ` 4 a fii� P.m. Requester: Po a No: - ��.s'J2 Sj�y EiApproved per applicable codes. Corrections required prior to approval. COMMENTS: 6KT 6A7 f - A-i 0JT ice` -,,S 4A El$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspect Dat /Q - - No.: Date: / INSPECTION RECORD ��� 3, �2 �� Retain a copy with permit INSPECTION NO. PERMIT NO. 4 CITY OF TUKWILA BUILDING DIVISION Iz 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ,rest" /3 t✓i Type o Inspection: , it L , .B Address: `7 ,314 .5e _ .0A./ % Date Called: Special Instructions: ....... • t 0e..+ I ,!4 , c • l .* i„., A ri:.—&- f ; 4j2 _-_ f- , h___ li ,t, . :1 , c k Date Wanted: 7 a p.m. Requester: Phone No: X25- - 1760 — 3 &'Z-- Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: p 1- Y14 411ZZ 9 /44 s- kte, (-4: a.— D $60.00 REINSPECTION F REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Untitled Page 0 • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company BELLEVUE PLBG/HTG INC 4256414222 14111 NE 24TH ST BELLEVUE WA 98007 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 600077194 ACTIVE BELLEPH288NU CONSTRUCTION CONTRACTOR 8/31/1972 8/4/2010 PLUMBING UNUSED Business Owner Information Name Role Effective Date Expiration Date CONOVER, MIKE Cancel Date 01/01/1980 Bond Amount CONOVER, FRANK TREASURER 01/01/1980 07/10/2002 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 WESTERN SURETY CO 69712515 07/24/2004 Until Cancelled $6,000.0007/30/2004 7 DEVELOPERS SURETY & INDEMNITY 855341C 07/24/2001 Until Cancelled 08/27/2004 $6,000.0008/07/2001 6 DEVELOPERS SURETY & INDEM CO 855341C 07/01/2001 07/24/2001 $4,000.0007/12/2001 5 AMWEST SURETY INS CO 111000482 07/01/1999 Until Cancelled 08/07/2001 $4,000.00 4 HARTFORD FIRE INS CO N5045964 07/01/1989 07/01/1999 $4,000.00 3 THE HARTFORD INS GROUP 5045964 07/01/1986 07/01/1989 https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= BELLEPH28 8NU Page 1 of 3 09/25/2008