Loading...
HomeMy WebLinkAboutPermit PG08-270 - FIDELITY INVESTOR CENTERFIDELITY INVESTOR CENTER 304 STRANDER BL G08 -270 Parcel No.: 6364200010 Address: Suite No: CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 304 STRANDER BL TUKW PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: PG08 -270 01/23/2009 07/22/2009 Tenant: Name: FIDELITY INVESTOR CENTER Address: 304 STRANDER BL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: STEVEN DESIMONE Address: 711 ATLANTIC AVE , BOSTON MA Contractor: Name: LAW PLUMBING INC Address: 8310 366 ST E , EATONVILLE WA Contractor License No: LAWPLPI956RA Phone: Phone: 617 - 348 -2800 Phone: 360 239 -0369 Expiration Date: 12/01/2009 DESCRIPTION OF WORK: TENANT BUILDOUT OF EXISTING SHELL Value of Plumbing /Gas Piping: Fees Collected: $30,000.00 $364.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND OUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 4 0 Water heater and /or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 2 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 4 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 0 Medical gas piping (6 +) inlets /outlets 1 2 Gas Piping 1 Gas piping outlets (0 -5) 0 3 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -270 Printed: 01 -23 -2009 City ofrukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -270 Issue Date: 01/23/2009 Permit Expires On: 07/22/2009 Permit Center Authorized Signature: Date: kD.3— 0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe ! t does o presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe ' ar frk. I am authorized to sign and obtain this plumbing /gas piping permit. Date: OCt Signature: Print Name: gar . 6tz-,' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -270 Printed: 01 -23 -2009 Parcel No.: 6364200010 Address: Suite No: Tenant: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 304 STRANDER BL TUKW FIDELITY INVESTOR CENTER PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -270 ISSUED 10/23/2008 01/23/2009 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -270 Printed: 01 -23 -2009 ®. City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: WJN� Print Name: y S _ ` t4-1 Date: ' " o` 7 " 09 ordinances governing or local laws regulating doc: Cond -10/06 PG08 -270 Printed: 01 -23 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:11wwx). ci. tukwila. wa. us Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. ?O g -s2-_7 a Public Works Permit No. Project No. *Vic (For office use only) Applications and plans must be complete in order to be accepted for plan review.. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: CO 310 Li #10� 01 0 Site Address`_ _ - Y1 6r1Z- A-N b.1a W p — Suite Number: Floor: Tenant Name: E L,1 ri l K ST friEN 'S New Tenant: ❑ Yes ❑ .. No Property Owners Name: W�A Mailing Address: —t14o1 ‘1,17 011112.4 6tA)P It fooat- L02 i}N6bL6b Gd1- -- City State oc Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: - 7M4.0%1 Pi . - DE 11a1014E- Day Telephone: 07. 31.4 8 . Z �O Mailing Address: 7t1 eer-rvN A azlll E -Mail Address: -6D65i mowik 62. 'S�= '����� �• �'� City Fax Number: 84g. $79 . 9 451 State Zip GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: L13o k (ipr� -'S - -- Mailing Address: 'Z%' Li f'• J Jt 't- %j '4 'P/T LL t44 ggIZ.J City State Zip Contact Person: - phi r -i -t - (?-134 Day Telephone: 2-06 VaZ 3(jt-C> E -Mail Address: fher17 -teX-- . (41215`'f Q f3RIfsoLfy 2S Contractor Registration Number: SN6 V (1 * 1a o -'3 Fax Number: Expiration Date: vtlbl ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: /� Contact Person: ? ec-o rpj.,0"' -E,_I >- E -Mail Address: rA5l,o AR4-10 Gd• ) onl g Gold ` Tbt1r—D- p e t3 ePie t`t M A ik t a S City Day Telephone: Fax Number: 6fleF=2m=Pbtfittri 617 6/9.57 °1 State Zip 447 611 5700 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: PP W44 t 1 5 Mailing Address: ipGh T- ANTE-2, -70 f c '3T ti i ✓-f Bo! •laN 1`14 o2Z10 City State Zip Contact Person: i`°t M(Sl le-C.) Day Telephone: CI7. 345. 9 E -Mail Address:_ 0/41,414.1.0 (9--e-cAcet emeEPS .cow Fax Number: 4f7._ 395. `j2z.4 \ Appliiaiions \Porms=Applicaiions On I.ine\3- 2006 = .Permit Application. toe R.6'kea: '9 .506 nn Page 1 of 6 PLUMBING AND GAS PIPING PERMIT .INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ off? Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): N/tNV $Jl tA9 Pr 1 c(5T I N4 fit" Building Use (per lnt'I Building Code): $001)41 cC.4›J Lid / /Fplz-& elo1C 1 (A Occupancy (per lnt'l Building Code): 72- Utility Purveyor: Water: Gar Sewer: 14-6- Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) 2' Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks '1- Dental unit, cuspidor Shower, single head trap Urinals 1 Dishwasher, domestic, with independent drain Lavatory ti I. I Water Closet Water heater and /or vent Additional medical gas inlets /outlets — six or more Building sewer or trailer park sewer Rain water system — per drain (inside building) Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment I Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas Q:\ Applications \Forms- Applications On Line\3 -2006 - Permit Applicatinn.dac Revised: 9 -2006 bh Page 5of6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AUTHORIZED AGENT: Signature: Print Name: dtry vA l' stfrioug. Mailing Address: 7l1 h rL 4rl ( AJE Date: 1 o /28p s Day Telephone: G1 7. 3445 . ZSp0 $btt'N erA c ziit1 State Zip City Date Application Accepted: (O3 -0 g Date Application Expires: _ .LLI --O Ct Staff Initials: me Q:\Applications \Forms - Applications On Line\3 -2006 - Permit Applicalton.doc Revised: 9 -2006 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-43 1 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -270 Address: 304 STRANDER BL TUKW Status: APPROVED Suite No: Applied Date: 10/23/2008 Applicant: FIDELITY INVESTOR CENTER Issue Date: Receipt No.: R09 -00128 Payment Amount: $308.00 Initials: WER Payment Date: 01/23/2009 10:01 AM User ID: 1655 Balance: $0.00 Payee: OKITSU CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1829 308.00 ACCOUNT ITEM LIST: Description PLUMBING - NONRES Account Code Current Pmts 000.322.103.00.0 308.00 Total: $308.00 1827 01/23 9707 TOTAL 308.00 doc: Receiot -06 Printed: 01 -23 -2009 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -270 Address: 304 STRANDER BL TUKW Status: PENDING Suite No: Applied Date: 10/23/2008 Applicant: FIDELITY INVESTOR CENTER Issue Date: Receipt No.: R08 -03593 Initials: WER User ID: 1655 Payment Amount: $56.00 Payment Date: 10/23/2008 10:28 AM Balance: $308.00 Payee: MARK RONISH TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 56.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 56.00 Total: $56.00 doc: Receiot -06 Printed: 10 -23 -2008 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 OL R ®- 2 7 L Projec -t: -- 1- ((ice k;"ILI naves-10✓ Type of Inspection: 1--I n.VA (— rA...ti^I') Address: 3 0 Li S z A-1.54F2 Date Called: Special Instructions: Date Wanted: I..{ _ i 0 S (a:nrm p.m. Requester: Phone No: -2-c G -- %C3 - --7 7 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: P40 r 0 C 4 elf:7---t‘iVA Date: REINSPECTION FEE REDUIR D. Prior to inspection, fee must be t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 'PECTION RECORD Retain a copy with permit PERMIT NO. Proje i fi -eb ;� 0 1:1'/1.5 h r- Type of,I.Gspection: ` 1 - � ,K 4 i, h ��1 Address: -.26 ` /$r',1?v4 iG4 Date Called: .. Special Instructions: Date Wanted:_ Requester: Phone e 2 a G / 7 -753-g7 Approved per applicable codes. ❑ Corrections required prior to approval. C •'i M NTS: 1/— wa Tf e-�— Date: 60.00 REINSPECTIO FEE R`(UIRED. Prior to inspection, fee must be paid at 6300 Southcent r Blv ., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit P 2 INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: / cLP -iz Type of 1 ection: 1 l Address: 36 9 u2� � Date Called: Special Instructions: Date Wanted: 2-2-09 /jam; %P-� Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Got /4 S.51-o-2,C j .>7 Inspector: Date: $60.0 1 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: PER ! IT CO :' i D COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -270 DATE: 10 -23 -08 PROJECT NAME: FIDELITY INVESTOR CENTER' SITE ADDRESS: 304 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Build ng D�i'visio n� Public Works l 0- Fire Prevention Structural n Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-28-08 Complete Comments: Incomplete n Not Applicable Permit Center Use Only ' . INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUESITHURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 11 -25 -08 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Untitled Page • 1 Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company LAW PLUMBING INC 3602390369 8310 366TH ST E EATONVI LLE WA 98328 PIERCE CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602555592 ACTIVE LAWPLPI956RA CONSTRUCTION CONTRACTOR 12/1/2005 12/1/2009 LAWPLH*989P8 PLUMBING UNUSED Business Owner Information Name Role Effective Date Expiration Date LAW, PHILIP J PRESIDENT 12/01/2005 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 PLATTE RIVER INS CO 4110209010/18/2007 Until Cancelled $6,000.00 10/23/2007 1 EMPIRE FIRE AND MARINE INS CO FS801490 10/18/2004 Until Cancelled 10/18/2007 $6,000.00 12/01 /2005 Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= LAWPLPI956RA 01/23/2009 ELECTRIC WATER HEATER SCHEDULE TAG NO. p . MANUFACTURER 1/2" HW SUPPLY TANK STORAGE GAL, RECOVERY RATE (GPH) RISE AT 100 RISE COLD WATER CHILLER EQUAL TO ELKAY MODEL ERS1 (OPERATING WEIGHT 40 LBS.) 2 WAY PILOT OPERATED SOLENOID VALVE FLOOD STOPPER 2" VENT 1/2" CW SUPPLY OPERATING WEIGHT LBS REMARKS VOLTS PHASE 1/2" FW SUPPLY TO COFFEE STATION REFER TO FLOOR PLAN FOR CONTINUATION. SUPPLY _ FLOOR DRAIN J.R. SMITH 2005Y-02-P050 2" NICKEL BRONZE PROVIDE DRAIN WITH TRAP PRIMER CONNECTION. PROVIDE TRAP PRIMER "PRECISION PLUMBING PRODUCTS INC" MODEL #P2 -500. LOCATE TRAP PRIMER IN JANITOR'S CLOSET. -I1 11 I A. 0. SMITH 1 -- - 12 277 1 3 110' CEILING MOUNT WATER HEATER ON SHELF ABOVE CEILING. PROVIDE DRIP PAN PIPED TO JANITORS SINK. PROVIDE WALL CARRIER TO SUIT. P -1A WATER CLOSET KOHLER KINGSTON K -4330 - SLOAN ROYAL 111 1" CW INTEGRAL J.R. SMITH 0210Y MOUNTED AT ADA HEIGHT. PROVIDE 1/2" HW> WITHIN WALL 2" VENT IN WALL COUNTERTOP 1 I 1 /2" CW KOHLER BARDON K- 4960 -ET COMPLETE LEAK DETECTION SYSTEM: FLOOD STOPPER BY FIRST SMART (COORDINATE 1 LOCATION WITH ELECTRICAL CONTR. AND ARCHITECTURAL LAYOUT) 1/2" FW WITHIN WALL t 1 I I � I WITHIN WALL INTEGRAL J,R. SMITH 0035 CHROME PLATED WATER DISPENSER EQUAL TO ELKAY MODEL LK2156 PROVIDE WALL CARRIER TO SUIT. MOUNTED AT ADA HEIGHT. AIR GAP 1/2" CAPPED CW SUPPLY FOR le I i:i: CI� CAXTON K -2210 17" x 14" REFRIDGERATOR. - 1/2" CW SUPPLY FOR FUTURE COFFEE MAKER. SCOT S- 60 -G -H METERING FAUCET 4' P -4 UNDER COUNTER MOUNTED 1 r • T ^ NOTE: FURNISH AND INSTALL SIEMIC RESTRAINTS FOR CHILLER IN BREAK ROOM SINK ■ 11 La ii I I I I 0 LRAD 2219 -60 -2 22" x 19 -1/2" 1/2" MARATHON 2302 -CP 1 2" CW 1/2" HW 1-1/2" OFFSET POLISHED CHROME COMPLIANCE W/ CPC 510.5 1 [ I I PROVIDE BACKFLOW PREVENTER EQUAL TO WATTS SERIES 7. (TYP. FOR 4) \ FILTRINE WATER FILTER MODEL 4 -TM 2 GPM. FINISH FLOOR 2" WASTE WITHIN WALL 0 WCO 0 CHICAGO FAUCETS 897 1/2" CW 1/2" HW - i P -6 I, • S REFER TO FLOOR PLAN FOR CONTINUATION CHICAGO FAUCETS - 2" WASTE TO SANITARY SYSTEM -R_ D K NTS \.. 01 .0 BREAK ROOM SINK DETAIL ELECTRIC WATER HEATER SCHEDULE TAG NO. TYPE MANUFACTURER MODEL NO. TANK STORAGE GAL, RECOVERY RATE (GPH) RISE AT 100 RISE ELECTRICAL DATA TEMP. SEIZING OPERATING WEIGHT LBS REMARKS VOLTS PHASE TYPE SUPPLY FD -1 FLOOR DRAIN J.R. SMITH 2005Y-02-P050 2" NICKEL BRONZE PROVIDE DRAIN WITH TRAP PRIMER CONNECTION. PROVIDE TRAP PRIMER "PRECISION PLUMBING PRODUCTS INC" MODEL #P2 -500. LOCATE TRAP PRIMER IN JANITOR'S CLOSET. EWH -1 ELECTRIC WATER HEATER A. 0. SMITH DEL -10 10 12 277 1 3 110' 135 MOUNT WATER HEATER ON SHELF ABOVE CEILING. PROVIDE DRIP PAN PIPED TO JANITORS SINK. PROVIDE WALL CARRIER TO SUIT. P -1A WATER CLOSET KOHLER KINGSTON K -4330 - SLOAN ROYAL 111 1" CW INTEGRAL J.R. SMITH 0210Y MOUNTED AT ADA HEIGHT. PROVIDE DRAIN SCHEDULE TAG NO. TYPE MANUFACTURER MODEL NO. OUTLET STRAINER REMARKS MANUFACTURER MODEL SIZE MANUFACTURER TYPE SUPPLY FD -1 FLOOR DRAIN J.R. SMITH 2005Y-02-P050 2" NICKEL BRONZE PROVIDE DRAIN WITH TRAP PRIMER CONNECTION. PROVIDE TRAP PRIMER "PRECISION PLUMBING PRODUCTS INC" MODEL #P2 -500. LOCATE TRAP PRIMER IN JANITOR'S CLOSET. PLUMBING FIXTURE SCHEDULE SYMBOL FIXTURE FITTING TRAP CARRIER REMARKS TYPE MANUFACTURER MODEL SIZE MANUFACTURER TYPE SUPPLY P -1 WATER CLOSET KOHLER KINGSTON K-4330 _ SLOAN ROYAL 111 1" CW INTEGRAL J.R, SMITH 0210Y PROVIDE WALL CARRIER TO SUIT. P -1A WATER CLOSET KOHLER KINGSTON K -4330 - SLOAN ROYAL 111 1" CW INTEGRAL J.R. SMITH 0210Y MOUNTED AT ADA HEIGHT. PROVIDE ELONGATED OPEN FRONT SEAT, PROVIDE WALL CARRIER TO SUIT. 6.. P -2 URINAL KOHLER BARDON K- 4960 -ET - SLOAN ROYAL 186 3/4" CW INTEGRAL J,R. SMITH 0035 PROVIDE WALL CARRIER TO SUIT. MOUNTED AT ADA HEIGHT. P -3 LAVATORY KOHLER CAXTON K -2210 17" x 14" SYMMONS SCOT S- 60 -G -H METERING FAUCET 1/2" CW 1/2" HW 1 -1/2" OFFSET POLISHED CHROME UNDER COUNTER MOUNTED PROVIDE OFFSET GRID DRAIN ASSEMBLY W/ TRUE BRO INSULATION ON PIPING UNDER LAVATORY,. P -4 BREAK ROOM SINK ELKAY LRAD 2219 -60 -2 22" x 19 -1/2" CHICAGO FAUCETS MARATHON 2302 -CP 1 2" CW 1/2" HW 1-1/2" OFFSET POLISHED CHROME LAY IN ELKAY LKAD35 ADA ACCESSIBLE BASKET STRAINER WITH OFFSET P - TRAP . PROVIDE TRUE BRO INSULATION ON PIPING UNDER SINK. [ P -5 MOP RECEPTOR FIAT TSB -100 24" x 24" CHICAGO FAUCETS 897 1/2" CW 1/2" HW - 3/4" HOSE CONNECTION P -6 HOSE BIBB CHICAGO FAUCETS 952CP 1 /2 CW P -7 DRINKING FOUNTAIN HALSEY TAYLOR OVL -II SEBP - - - " 1 2 CW / 1-1/2" P -TRAPS - BASE BUILDING CW TO WALL HYDRANTS (N (6 i LP:7 SPECIFICATIONS GENERAL 1. GENERAL PROVISIONS: BEFORE SUBMITTING BID, VISIT AND CAREFULLY EXAMINE SITE TO IDENTIFY EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT WORK OF THIS SECTION. NO EXTRA PAYMENT WILL BE ALLOWED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED BY EXPERIENCED OBSERVER. PERFORM WORK AND PROVIDE MATERIAL AND EQUIPMENT FOR SYSTEMS SHOWN ON DRAWINGS AND AS SPECIFIED IN THIS SECTION. COMPLETELY COORDINATE WORK OF THIS SECTION WITH WORK OF OTHER SECTIONS AND PROVIDE COMPLETE AND FULLY FUNCTIONAL INSTALLATION. DRAWINGS AND SPECIFICATIONS FORM COMPLEMENTARY REQUIREMENTS; PROVIDE WORK SPECIFIED AND NOT SHOWN, AND WORK SHOWN AND NOT SPECIFIED AS THOUGH EXPRESSLY REQUIRED BY BOTH. 2. REFERENCE STANDARDS: PERFORM WORK STRICTLY AS REQUIRED BY RULES, REGULATIONS, STANDARDS, CODES, ORDINANCES, AND LAWS OF LOCAL, STATE, AND FEDERAL GOVERNMENTS, AND OTHER AUTHORITIES THAT HAVE LAWFUL JURISDICTION. INCLUDING BY NOT LIMITED TO: a) SEATTLE PLUMBING CODE, b) SEATTLE STATE BUILDING CODE, c) SEATTLE DEPARTMENT OF ENVIRONMENTAL PROTECTION, d) ALL APPLICABLE NFPA STANDARDS, e) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), f) SEATTLE DEPARTMENT OF PUBLIC SAFETY CODES, g) SEATTLE ARCHITECTURAL ACCESS BOARD. 3. SCOPE OF WORK: PERFORM WORK AND PROVIDE MATERIAL AND EQUIPMENT AS SHOWN ON DRAWINGS AND AS SPECIFIED IN THIS SECTION OF THE SPECIFICATIONS. GIVE NOTICES, FILE PLANS, OBTAIN PERMITS AND LICENSES, PAY FEES AND BACKCHARGES, AND OBTAIN NECESSARY APPROVALS FROM AUTHORITIES THAT HAVE JURISDICTION AS REQUIRED TO PERFORM WORK IN ACCORDANCE WITH ALL LEGAL REQUIREMENTS AND WITH SPECIFICATIONS AND DRAWINGS. 4. RELATED WORK: THE FOLLOWING WORK IS NOT INCLUDED IN THIS SECTION AND WILL BE PROVIDED UNDER OTHER SECTIONS: 1)PAINTING, EXCEPT AS SPECIFIED, 2)ELECTRICAL POWER WIRING FOR ALL EQUIPMENT, 3)TEMPORARY LIGHT, POWER, WATER, HEAT, GAS AND SANITARY FACILITIES FOR USE DURING CONSTRUCTION. 5. SUBMITTALS: I SUBMIT PRODUCT DATA FOR E S _ M TTALS: S BMIT 5 COMPLETE COPIES OF PRODUG EQUIPMENT Q SPECIFIED OR SHOWN ON DRAWINGS PREPARED BY MANUFACTURERS, SUPPLIERS AND VENDORS. SUBMITTALS SHALL INCLUDE: 1) TESTING REPORTS, 2) ALL CUT SHEETS OF THE FOLLOWING, BUT NOT LIMITED TO: FIXTURES, PIPE MATERIALS, FITTINGS, VALVES, WATER HEATERS, DRAINS, INSULATION, HANGERS, ETC. 6. OPERATION AND MAINTENANCE DATA: PREPARE AND SUBMIT PRIOR TO THE COMPLETION OF THE PROJECT OPERATING AND MAINTENANCE MANUALS INCLUDING SYSTEMS DESCRIPTIONS AND WIRING DIAGRAMS FOR THE FOLLOWING: a) WATER HEATERS. 7. RECORD DRAWINGS: RECORD DRAWINGS SHALL BE SUBMITTED FOR REVIEW PRIOR TO THE COMPLETION OF THE PROJECT SHOWING THE "AS CONDITION INCLUDING WORK INSTALLED AND ALL MODIFICATIONS OR ADDITIONS TO ORIGINAL DESIGN. THE CONTRACTOR SHALL OBTAIN THE AUTOCAD FILES FOR PREPARATION OF AS -BUILT DRAWINGS FROM THE ARCHITECT, THE ARCHITECT AND ENGINEER ARE NOT GRANTING TO THE CONTRACTOR ANY OWNERSHIP OR PROPERTY INTEREST IN THE CADD DRAWINGS BY THE DELIVERY OF THE CADD FILES TO THE CONTRACTOR, THE CONTRACTOR'S RIGHTS TO USE THE CADD FILES AND DRAWING ARE LIMITED TO USE FOR THE SOLE PURPOSE OF ASSISTING THE CONTRACTOR'S PERFORMANCE IN ITS CONTRACTUAL OBLIGATIONS UNDER THE CONTRACT WITH RESPECT TO THIS PROJECT. THE ARCHITECT AND ENGINEER ARE GRANTING NO FURTHER RIGHTS. ANY REUSE AND /OR OTHER USE BY THE CONTRACTOR WILL BE AT THE CONTRACTOR'S SOLE RISK AND WITHOUT LIABILITY TO THE ARCHITECT AND ENGINEER. 8. WARRANTIES: GUARANTEE WORK OF THIS SECTION IN WRITING FOR ONE YEAR FROM DATE OF OWNERS ACCEPTANCE OF CERTIFICATE OF SUBSTANTIAL COMPLETION. REPAIR OR REPLACE DEFECTIVE MATERIALS, EQUIPMENT, WORKMANSHIP AND INSTALLATION THAT DEVELOP WITHIN THE PERIOD, PROMPTLY AND TO OWNER'S SATISFACTION AND CORRECT DAMAGE CAUSE IN MAKING NECESSARY REPAIRS AND REPLACEMENTS UNDER GUARANTEE WITHIN CONTRACT PRICE. 9. COORDINATION: CONFER WITH ALL OTHER TRADES RELATIVE TO LOCATION OF ALL APPARATUS AND EQUIPMENT TO BE INSTALLED AND SELECT LOCATIONS SO AS NOT TO CONFLICT WITH WORK OF OTHER SECTIONS. 10. CUTTING AND PATCHING: PROVIDE ALL CUTTING AND PATCHING NECESSARY FOR THE PROPER INSTALLATION OF WORK TO BE PERFORMED UNDER THIS SECTION. 11. SEISMIC RESTRAINT REQUIREMENTS: PROVIDE SEISMIC RESTRAINTS AS REQUIRED IN ACCORDANCE WITH THE ILLINOIS STATE BUILDING CODE. 12. ACCESSIBILITY: ALL WORK SHALL BE INSTALLED SO THAT PARTS REQUIRING PERIODIC INSPECTION MAINTENANCE AND REPAIR ARE ACCESSIBLE. 13. ELECTRICAL WORK: ALL ELECTRICAL APPARATUS AND CONTROLS FURNISHED AND THE INSTALLATION THEREOF, AS A PART OF PLUMBING WORK, SHALL CONFORM TO APPLICABLE REQUIREMENTS UNDER THE ELECTRICAL DRAWINGS AND SPECIFICATION. 4" SAN NOT TO SCALE FCO P -1A 4" VTR Gtom (0/tAi\ �i DOMESTIC WATER DISTRIBUTION RISER 3" V -" P -3 EXISTING WATER METER M: \2008 \20080075- Fidelity Seattle, WA \Plurnbing \20080075 P01.01 PLUMB LEGEND, DETAILS, SCHEDULES & SPEC.dwg [30x42] October 16, 2008 - 9:04am cbutts P -3 BASE BUILDING CW TO WALL HYDRANT 2" V 0 P -\ N N I mo " N 1 v P -3 \ P -3 2 " • _ WASTE & VENT RISER NOT TO SCALE 2" WATER SERVICE FROM STREET PRODUCTS 1. PLUMBING FIXTURES AND TRIM: REFER TO ARCHITECTURAL AND PLUMBING DRAWINGS FOR QUANTITIES, LOCATIONS AND MOUNTING HEIGHTS OF FIXTURES PROVIDED UNDER THIS SECTION. FIXTURE TRIM, TRAPS, FAUCETS, ESCUTCHEONS AND WASTE PIPES EXPOSED TO VIEW IN THE FINISHED SPACES SHALL BE I.R.S. BRASS WITH POLISHED CHROMIUM PLATING OVER NICKEL FINISH. 2. PIPE MATERIALS: a) SERVICE: ABOVE GROUND WATER PIPING, PIPE MATERIAL :TYPE L HARD DRAWN COPPER TUBING, ASTM B88 FITTING MATERIAL: WROUGHT COPPER AND BRONZE SOLDER JOINTS, PIPE JOINT: 95 -5 LEAD -FREE SOLDER, b) SERVICE: ABOVE GROUND, SANITARY WASTE, AND VENT, PIPE MATERIAL: DWV COPPER TUBE, OR TYPE M COPPER FOR DRAINAGE ONLY, CAST IRON NO HUB (CISPI301) FITTING MATERIAL: WROUGHT COPPER DRAINAGE FITTINGS TO SUIT PIPE MATERIAL, CAST IRON, PIPE JOINT: SOLDER WITH 95 -5 LEAD FREE SOLDER, STAINLESS STEEL COUPLING WITH NEOPRENE GASKET. 3. VALVES: BALL VALVES SHALL BE FULL PORT WITH STAINLESS STEEL STEM AND BALL, BRONZE BODY, SOLDER AND EQUAL TO APOLLO 77 -200 SERIES FOR PIPING UP TO 2" SIZE. 4. INSULATION: a) INSULATION SHALL BE BY OWENS - CORNING, CERTAIN -TEED OR MANVILLE, b) INSULATION, JACKETS AND ADHESIVES SHALL BE FLAME RETARDANT AND SHALL HAVE ASTM E -84 FIRE HAZARD RATINGS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED AND 50 FUEL CONTRIBUTED, c) HOT WATER SUPPLY PIPING SHALL BE INSULATED WITH HEAVY DENSITY FIBERGLASS WITH SELF - SEALING LAP AND ALL SERVICE JACKET. FITTINGS AND VALVES SHALL BE INSULATED WITH TWO LAYERS BLANKET INSULATION WITH PVC COVERS, INSULATION SHALL BE RATED FOR MAXIMUM OPERATING TEMPERATURE OF 450'F. INSULATION THICKNESS SHALL BE 1 ", d) COLD WATER SUPPLY PIPING, VALVES AND FITTINGS SHALL BE INSULATED AS SPECIFIED FOR HOT WATER SUPPLY PIPING. IN ADDITION, CONTINUOUS VAPOR BARRIER SHALL BE MAINTAINED. INSULATION THICKNESS SHALL BE 1 ". 5. HANGERS, ANCHORS, CLAMPS AND INSERTS: a) PROVIDE STEEL BAND HANGERS FOR PIPING 4" AND SMALLER. SUPPORT PIPING FROM BUILDING STRUCTURE TO MAINTAIN REQUIRED GRADE AND PITCH OF PIPE LINES, PREVENT VIBRATION, SECURE PIPING IN PLACE. SECURE HANGERS TO INSERTS WHERE PRACTICAL. HANGER RODS SHALL HAVE MACHINE THREADS, b) HANGER RODS SHALL BE CONNECTED TO BEAM CLAMP, UL- APPROVED CONCRETE INSERTS OR PHILLIPS OR APPROVED EQUAL EXPANSION SHIELDS. RAMSET OR POWER DRIVEN INSERTS WILL NOT BE ALLOWED, c) HANGERS SHALL BE SPACED AT NO MORE THAN EVERY 10 FT. FOR ALL V2" WATER PIPING. d) HANGER SPACING SHALL MEET ALL REQUIREMENTS OF STATE AND LOCAL CODES. 6. SLEEVES AND PENETRATIONS: a) PIPE SLEEVES THROUGH FIRE -RATED CONSTRUCTION SHALL BE SCHEDULE 40 STEEL. SLEEVES THROUGH PARTITIONS AND NON -FIRE -RATED CONSTRUCTION SHALL BE 22 GAUGE GALVANIZED STEEL WITH LOCK LONGITUDINAL SEAMS, b) FIRE STOP PENETRATION SEALS IN FIRE -RATED CONSTRUCTION SHALL BE CERAMIC FIBBER, MINERAL FIBBER, OR SILICONE FOAM. PROVIDE MINERAL FIBBER BOARD, MATTING OR PUTTY FOR DAMMING AND FORMING. FINISH SEALS FLUSH TO WALL SURFACE AND FILL GAPS WITH SILICONE ADHESIVE SEALANT CAULKING, c) PACKING FOR SLEEVES THAT DO NOT REQUIRE Q REQ RE MAINTENANCE OF FIRE RATING SHALL BE OAKUM, SILICATE FOAM, CERAMIC FIBBER OR MINERAL FIBBER WITH APPROVED SEALANT. PACK OR FOAM TO WITHIN ONE INCH OF BOTH WALL SURFACES. SEAL PENETRATION PACKING WITH APPROVED CAULKING AND PAINTABLE WATER -PROOF MASTIC SURFACE FINISH OR SILICONE CAULKING. 7. WATER HAMMER ARRESTORS: a) STAINLESS STEEL WATER HAMMER ARRESTORS SHALL BE INSTALLED ON WATER SUPPLY LINES TO PLUMBING FIXTURES TO CONTROL WATER HAMMER, WATER HAMMER ARRESTORS SHALL BE SIZED AND SELECTED IN ACCORDANCE WITH P.D.I. STANDARD WH2O1. WATER HAMMER ARRESTORS SHALL BE ZURN Z1700, JAY R. SMITH, JOSAM OR APPROVED EQUAL. PROVIDE ACCESS PANEL AT WATER HAMMER ARRESTORS, WHERE REQUIRED. EXECUTION 1. IDENTIFICATION: a) FURNISH AND AFFIX APPROVED ADHESIVE BANDS IDENTIFYING THE SERVICE AND DIRECTION OF FLOW OF EACH PUMP SYSTEM INSTALLED UNDER THIS WORK, b) PROVIDE VALVE TAGS ON ALL VALVES. VALVE NUMBERS AND LEGEND ON VALVE TAGS SHALL CORRESPOND TO NUMBERS INDICATED ON RECORD DRAWINGS AND VALVE LIST. 2. TESTING: THE PLUMBING SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF THE PLUMBING CODE AND FUEL GAS CODE. 3. MATERIALS AND WORKMANSHIP: MAINTAIN MAXIMUM HEADROOM AT ALL TIMES. DO NOT RUN PIPES EXPOSED UNLESS SHOWN EXPOSED ON DRAWINGS. MATERIAL AND EQUIPMENT SHALL BE NEW AND INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDED BEST PRACTICE SO THAT COMPLETED INSTALLATION SHALL OPERATE SAFELY AND EFFICIENTLY. 4. CONTINUITY OF SERVICES: DO NOT INTERRUPT EXISTING SERVICES WITHOUT OWNER'S APPROVAL. 5. ACCESS: PROVIDE PROPER ACCESS TO EQUIPMENT THAT REQUIRE INSPECTION, REPLACEMENT OR REPAIR. ACCESS PANELS SHALL BE A MINIMUM OF 12" X 12 ". 6. CLEANING: a) CLEAN SYSTEMS THOROUGHLY BEFORE TESTING. FIXTURES, EQUIPMENT, PIPE, VALVES AND FITTINGS SHALL BE FREE OF GREASE, METAL CUTTINGS, DIRT AND OTHER FOREIGN MATERIAL, b) REPAIR STOPPAGE, DISCOLORATION AND DAMAGE TO PARTS OF BUILDING, FINISH AND FURNISHINGS DUE TO FAILURE TO PROPERLY CLEAN PIPING SYSTEM. 7. DISINFECTION OF WATER SYSTEMS: WATER PIPING SYSTEMS SHALL BE THOROUGHLY DISINFECTED WITH A SOLUTION CONTAINING NO LESS THAN 50 PARTS PER MILLION OF AVAILABLE CHLORINE. CHLORINATING MATERIALS SHALL BE EITHER LIQUID CHLORINE OR SODIUM HYPOCHLORITE SOLUTION, SHALL BE INTRODUCED INTO THE SYSTEM AND DRAWN TO ALL POINTS IN THE SYSTEM. DISINFECTION SOLUTION SHALL BE ALLOWED TO REMAIN IN SYSTEM FOR 24 HOURS, DURING THIS TIME, VALVES AND FAUCETS SHALL BE OPENED AND CLOSED SEVERAL TIMES, AFTER DISINFECTION, SOLUTION SHALL BE FLUSHED FROM THE SYSTEM WITH CLEAR WATER UNTIL RESIDUAL CHLORINE CONTENT IS NO GREATER THAN 0.2 PARTS PER MILLION, 2 WAY PILOT OPERATED SOLENOID VALVE FLOOD STOPPER EXPANSION TANK EQUAL TO THERM -X -TROL #ST -5 FROM WATER DETECTION CONTROLLER COMPLETE LEAK DETECTION SYSTEM: FLOOD STOPPER BY FIRST SMART (COORDINATE LOCATION WITH ELECTRICAL CONTR. AND ARCHITECTURAL LAYOUT) TO WATER DETECTION CONTROLLER 1 Y4" RELIEF VALVE DRAIN TO JANITOR'S SINK. %' HOT WATER T T GENERAL LEGEND 0 FD FLOOR DRAIN I CO CLEANOUT 0 FCO FLOOR CLEANOUT 30 P -TRAP ELBOW DOWN OR DROP CAP OR END OF PIPE UNION PIPE CONTINUATION BALL VALVE FLOW IN DIRECTION OF ARROW HB HOSE BIBB HC HANDICAPPED ACCESSIBLE CTE CONNECT TO EXISTING �E EWH - FINISHED FLOOR r� N." HOT WATER VACUUM BREAKER I UNION (TYP.) BALL VALVE (TYP.) P & T RELIEF WALL SIESMIC BRACING AS REQUIRED DRAIN VALVE 2" DEEP GALV. STEEL DRIP PAN WITH 1 Y4 DRAIN. PROVIDE 2" CLEARANCE ALL AROUND. ANGLE IRON SUPPORT 1 Y4" DRIP PAN DRAIN TO JANITOR'S SINK. ° WALL MOUNTED WATER HEATER DETAIL ABBREVIATIONS NTS CO CW DN 24 FCO HW TYP V VTR W CLEANOUT COLD WATER DOWN FIXTURE NUMBER FLOOR CLEANOUT HOT WATER TYPICAL VENT VENT THRU ROOF WASTE PIPING LEGEND FW Fw CW HW HWR S or W 5 or W S or W V COLD WATER HOT WATER HOT WATER RETURN SOIL OR WASTE ABOVE GROUND SOIL OR WASTE BELOW SLAB (FLOOR PLAN) SOIL OR WASTE BELOW SLAB (ISOMETRIC RISER) VENT ABOVE GROUND FILTERED WATER FW FILTERED WATER BELOW SLAB EXISTING PIPE DESIGNATION INDICATOR DETAIL DESIGNATION NUMBER DETAIL DESIGNATION DRAWING ?GoB Z70 F Permit 1 Plar reView apprc Approval of const the violation of an >t approved Fiold 1 By Date: )QE QQt49L1 ' 5 VII 0 Fidelity INVESTMENTS South Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS 'LE C P 10.E.WAIL sal is subject to errors and emissions. uction documents does not authorize / adopted code or ordinance. Reccgpt . y and conditions is ackncwlierted: 01.3- act 117 of Tukwila ..DING DRISIONI IA �r 1 Ile �4 SOP P 0 TT , �� 91 9 0 r •: i +? s ' a l l 1 i 1 Seal/Signature Project Name Project Number 20080075 1 CAD File Name 20080075J'01.01 Description NTS Q2006 Gensler Issue Date & Issue Description By Check 01 07/02/08 RAE JAL ISSUED FOR CONSTRUCTION REVISIONS No changes shall be ma P01.07 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210 -1964 T 617- 345 -9885 F 617 -345 -4226 W www.rdkengineers.com SEPARATE PERMIT REQUIRED FOR: •Mechani al Ii Electrical Cl Plumbing 0 Gas Piping City of Tukwila BUILDING DIVISION e 0 n e NOTE: Revisions will require a new plan submittal 1 and may include additional plan review fees, Fidelity Investor Center - SEATTLE BRANCH sco PLUMBING LEGEND, DETAILS, SCHEDULES & SPECIFICATIONS 1Scale RECEIVED OCT 232000 PERMIT CENTER ti 3 i" CW DROP TO WALL HYDRANT Y2" CW DROP M: \2008 \200B0075 — Fidelity Seattle, WA \Plumbing \20080075 P02.01 PLUMB PLAN 1ST FLP.dwg [30x42] October 16 , 2008 — 9:04am cbutts L EWH -1— (MOUNTED ON WALLABOVE P -5) Y4" HW DROP 3 4" CW DROP 2 "V DN 2" CW CAPPED CONNECTION 4" SAN DN & 3" V 2" V DN 2" SAN & 2" V 4 " SAN &2 "V 2 "VDN 2" V DROP (4)2 "W &2 "V 1 X" CW DROP Y2 HW DROP FCO 2" WH P -3 P -6 P -3 FD -1 P -1 L 0 o 1" CW CAPPED CONNECTION 4" RL DN 4" OD UP PROVIDE 1 X" WATER CONNECTION FOR IRRIGATION —2"V DN 1 "W &V 2 "W DN -2 "V 4" CW DROP. 4" RL DN FCO 0 CO 2" WATER METER PROVIDED BY WATER COMPANY c� w co 4" CO rr r 4" RL DN 4" OD UP 4 "RLUP P -4 J C] X" CW DROP 2" W DN & V X" HW DROP Y " 2 U 0 LI 0 WH 6" OVER FLOW DRAIN TO TERMINATE 18" ABOVE FINISHED GRADE Y2 "CWDN 4 CW DROP TO WALL HYDRANT 6" OVER FLOW DRAIN TO TERMINATE 18" ABOVE FINISHED GRADE KEY NOTES SHEET NOTES CODE COVPUN APPRO KV - b 20Z CM Cg TuVAla \ iaoG_vytsioo \ 1. REFER TO DRAWING P01.01 FOR PLUMBING LEGEND, DETAILS, SCHEDULES, AND SPECIFICATIONS pr os 270 South Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS 1 Seal/Signature 1 Project Name Issue Date & Issue Description By Check 01 07/02/08 RAE TJG ISSUED FOR CONSTRUCTION Fidelity Investor Center — SEATTLE BRANCH 1 Project Number 20080075 1 CAD File Name 20080075302.01 1 Description PLUMBING PLAN FIRST FLOOR 1 Scale y 4'= 1' -0 01' 2' 4' P02.01 02006 Gensler Fidelity INVESTMENTS 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210-1964 T 617- 345 -9885 F 617 - 345 -4226 W www.rdkengineers.com RECEIVEV OCT 232008 PERMIT CENTEF,