Loading...
HomeMy WebLinkAboutPermit PG08-278 - OLD SPAGHETTI FACTORYOLD SPA HETTI FACTORY 17100 SOUTHCENTE'. PY SUITS 160 GO 278 Parcel No.: 2623049081 Address: Suite No: Cityaf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 17100 SOUTHCENTER PY TUHW Permit Number: Issue Date: Permit Expires On: PG08 -278 03/16/2009 09/12/2009 Tenant: Name: OLD SPAGHETTI FACTORY Address: 17100 SOUTHCENTER PY SUITE 160 , TUKWILA WA Owner: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE , BELLEVUE WA Contact Person: Name: BOB MARTIN Address: 0715 SW BANCROFT ST , PORTLAND OR Contractor: Name: BUSH PLUMBING & MECHANICAL INC Address: PO BOX 375 , EAST OLYMPIA WA Contractor License No: BUSHPMI077JA Phone: Phone: 503- 225 -0433 Phone: 360 456 -8263 Expiration Date: 04/01/2010 DESCRIPTION OF WORK: INSTALL COMPLETE WATER, SEWER AND GAS PIPE SYSTEMS. FOR RESTAURANT TENANT IMPROVEMENT. Value of Plumbing /Gas Piping: Fees Collected: $85,000.00 $1,119.25 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per dram (inside bldg) 0 0 Water heater and /or vent 2 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 15 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 7 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 11 Medical gas piping (6 +) inlets /outlets 1 10 Gas Piping 2 Gas.piping outlets (0 -5) 5 6 Gas piping outlets (6 +) 10 * *continued on next page ** doc: UPC -10/06 PG08 -278 Printed: 03 -16 -2009 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PGO8 -278 Issue Date: 03/16/2009 Permit Expires On: 09/12/2009 Permit Center Authorized Signature: Alao, 3`k�` °1 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th- erform. �- of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: .�. r Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -278 Printed: 03 -16 -2009 Parcel No.: 2623049081 Address: Suite No: Tenant: ® • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 17100 SOUTHCENTER PY TUKW OLD SPAGHETTI FACTORY PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -278 ISSUED 11/06/2008 03/16/2009 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -278 Printed: 03 -16 -2009 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: P � Print Name: Date: ` I LP' 01 doc: Cond -10/06 PG08 -278 Printed: 03 -16 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 21, 2-Y )LI-- RQ 9 1 _ Suite Number: % t Site Address: � ��o SO VT -irFC� 7�.I �� ��p Q Floor: � Tenant Name: OSF m E U O *JA-L -/ The PuSs/r 6 Na New Tenant: Dir Yes ❑ ..No Property Owners Name: 606 Pf2OP PS Z-L- Mailing Address: V// - /3 V 1-)/ACC Sir e6-7_2_ V0c WA City State Name: 46(98 Mailing Address: E -Mail Address: M/- i27)A) 071 .5) NC/ f aczeit Q 7V7e GSc /na,tY 2 Day Telephone: t�p'/1i2�9�1.t0 City CO/ti Fax Number: 92006 Zip (503) 22-5 -0433 QrQ_ 97Z3`'l State Zip 07):57) 226 -6 0/ � Company Name: _ A)P sd/2 F Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Company Name: .&977 " 6&'()a/C -OS /f f re- c7v,eC L-Z-/9 p , / Mailing Address: 2 5L S` 6. 1�3t/2/ .27/OE SA. / /�%L/9hUJ17 OR 97Z/ 7 � ' �� City State Zip V Contact Person: C' Ff M9iVi/tia t%O Day Telephone: 3)226 - 36 17 E -Mail Address: °L'F4 6 SPXL /gyp _ C'CM Fax Number: 3� 226 - 07/ S- Company Name: (7 »!9t• '//l/ 7C/A/& JZRZ.. Mailing Address: /TD ,/,Gf /3t7/7 ,_5-1e-• S - 771 Contact Person: d...tet/C-iC MO/Pie/S. Day Telephone: E-Mail Address: Fax Number: City sv re" 3oa Q:\Applications\Forms- Applications On Line \3-2006 - Permit Application.doc Revised: 9 -2006 bh x6- r) A- f le ofd. S he fig-06R G[�i4 P8Y4 State Zip 206 z S - 412 20 6 2-S5 - 06 /$ Page 1 of 6 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: — NOS Sc)RE -- Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: + s5 000 —7S(000 -I. Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ 14 Scope of Work (please provide detailed information): ii/,S `� a� � £(414 j S'e�l' iJ/ 2?. /!'l67�teak 9 S /45/J/ 47/1 4.1.€ CEA; 7goey . 1 k l' i • _ MLL _ /L v n I / 101 too (as Building Use (per Int'I Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: ..:i.r� -�,ji fi, , E fixture Typ .� ,;r�,�,� .. � Oty,.� f ?r F>>xtttrO Ype:v � , ...,.Oiy tttr T �; a F x C.. Yp�t3'" .., ., YP Offitiri l 'e Bathtub or combination bath/shower Drinking fountain or water cooler (per head) /. Wash fountain / Gas piping outlets /S. Bidet / Food -waste grinder, commercial Receptor, indirect waste �/ Clothes washer, domestic /' Floor drain /S– Sinks 0L i2. Dental unit, cuspidor — Shower, single head trap .......-+ Urinals Dishwasher, domestic, with independent drain Lavatory '°] Water Closet 6. Building sewer or trailer park sewer Rain water system – per drain (inside building) Water heater and /or vent 2, Additional medical gas inlets /outlets – six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors ,/ Repair or alteration of water piping and/or water treating equipment ' Repair or alteration of drainage or vent piping ," Medical gas piping system serving one to five inlets/outlets for specific gas / Q:WpplicationsTonns- Applications On Line - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN Signature: ORIZED Date: r/ Print Name: Mailing Address: Day Telephone: City State Zip Date Application Accepted: U' (49 09 Date Application Expires: �_ r D p Staff Initials: (i4e. Q:Wpplications\Forms- Applications On LineU -2006 - Permit Application.doc Revised: 9 -2006 bh Page 6 of 6 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049081 Permit Number: PG08 -278 Address: 17100 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 11/06/2008 Applicant: OLD SPAGHETTI FACTORY Issue Date: Receipt No.: R09 -00048 Initials: WER User ID: 1166 Payment Amount: $905.00 Payment Date: 01/09/2009 03:32 PM Balance: $0.00 Payee: OSF INTERNATIONAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1315 905.00 ACCOUNT ITEM LIST: Description GAS - NONRES PLUMBING - NONRES Account Code Current Pmts 000.322.103.00.0 165.00 000.322.103.00.0 740.00 Total: $905.00 doc: Receiot -06 Printed: 01 -09 -2009 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us RECEIPT Parcel No.: 2623049081 Permit Number: PG08 -278 Address: 17100 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 11/06/2008 Applicant: OLD SPAGHETTI FACTORY Issue Date: Receipt No.: R08 -03704 Payment Amount: $214.25 Initials: WER Payment Date: 11/06/2008 02:50 PM User ID: 1655 Balance: $905.00 Payee: OSF INTERNATIONAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1314 214.25 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Account Code Current Pmts 000/345.830 214.25 Total: $214.25 doc: Receiot -06 Printed: 11 -06 -2008 /a INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER IT NO. CITY OF TUKWILA BUILDING DIVISION P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: —Type of �spection:„. , 0Z -A S , 77 1- / //1/4- / Address: Date Called: /7/06 se ,e?QkLLI9c� Special Instructions: Date Wanted: a.m. 6 -2_ -Dc Requester: Phone No: NIApproved per applicable codes. Corrections required prior to approval. COMMENTS: f ) P d,'d)i5 lidvVe'(1-71/:94 S- Kiin 1 z / d/A- F •sr, p /'ir° AS AD iAl /(. - OF'n• o4d-/e .-S NIApproved per applicable codes. Corrections required prior to approval. COMMENTS: f ) P d,'d)i5 lidvVe'(1-71/:94 S- Kiin 1 z / d/A- F •sr, p /'ir° AS AD iAl /(. - OF'n• o4d-/e .-S Inspector: Date: G- z5 -a5 INSPECTION FEE R = ' UIRED. Pr or to inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 11-2- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 5 >W Type ofjpsgectiory: / Address: :f A a / Date Called: ,/ Special Instructions: j Date Wanted: G —22 - Q `+p.. Requester: Phone No: -- , $� / JApproved per applicable codes. Corrections required prior to approval. COMMENTS: . /ea /,/Pi- A a / 7196 /1 ,/ 3.) fl o T Cf/T Ste, at/ -- , $� / 6 1 N-5i' Date 0 REINSPECTION FA REQUI D. Prior to inspection, fee must be at 6300 Southcenter Blvd., S te 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. 'PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pegg:-Z7u \cL- Project: out SPA 6r1 T Type of Inspection: F, N 4 r 4 /-- L) / p 'A' /1 - L esJ �� ,, Address: 17/ o d Seh11hgok1 '' P'-1 Date Called: . 17 . , Special Instructions: Date Wanted: Co— / "] - c.-"9 .m. p.m. Requester: Phone No: Approved per applicable codes. orrections required prior to approval. COMMENTS: I ,A _ ,L4 .' d% L ,ilif..,) %�? 4 /-- L) / p 'A' /1 - L esJ �� ,, . 17 . , / d�� - L . - ,- ._A-.- k 2 (i'&, r r„..Af,> e AJC. -& (4 t a?f1'1, to!: t ( , e_t IT '1 L (; b (1 ��. /-ri I — r k Jr I fA 16.&p,41-1 h e-:t 3--,si) „-, . Inspecrr: &Jo Date: / , 1'7 _ 1 El$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3 70 i PG 08s. -Z'r' Pr01 U 3 • Type of Inspection: Ai "t 4 -4-✓r �%a,., Address: r, J (� < .S � �{,,� � ?Ai Date ec (ti A kb . -h %;, Special Instructions: / Date Wanted: 2 ,.....,W,, p.m. Requester: 4c) A A 0/7 Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: iJ J I t' iC6 A s 7-'k 57— A- 4 44^ 11 ../1 /lip t JA P_r 12,.1 u. A, 1 LA it" t' r a L ? I . -n -%0 49.r : A 4c) A A 0/7 It Inspecto r` iJ J I t' Date: / _ 3 - 0 ❑$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPE ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: oLD s(.ram rL Type f Inspection: �f(e,(4- ii\—) Address: 1`7100 ' •k I40fnl44'ti Date Called: Special Instructions: Date Wanted: — (a 0 Cj a, Requester: Phone No .- 03 -12d -2L2-7 () Approved per applicable codes. D Corrections required prior to approval. COMMENTS: P. Inspect Date: $• REINSPEC ION FEE R 'UIRED. 'riorto inspection, fee ust be 6300 Southcenter Blvd. Suite 100. Call to schedule reinspection. Recei T No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. N �' (206)431 -3670 Project: _ OLD c; ‘.)6,149E 0 4i Type of Inspection: 1 PvC bi,— 1 _ 6vk-'j V Address: 1-71 (3 0 j �/ 'e IA62 N'e v 0 -' NA Date Called: Special Instructions: Date Wanted: 1- 1 - ^2 -91 -0cl p.m. Requester: _ <}yo (A4Af e-t� Phone No: 3&C3 —570- 3Lo -2) 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: FA 10 AAA) m 14-479 2 Ls -.vJry - ST-4 i P _c, -- A A p , < 7 en N t h -s -y , Rai c. 2� ( _ lie-sA..) 5-1-4, _ <}yo (A4Af e-t� �3 Pqlo 14,l r V Fr,4vwrirt Cyr PAA,n - *IN,* spe f: rum `l ,� -�_ D e: z� ❑6 .00 REINSPECTION' FEE REQUIRE DI. Prior to inspection, fee must be d at 6300 Southcenter Blvd., Suite 1(00. Call to schedule reinspection. Receipt No.: Date: ._ - - .. .a..._��.. r . .. _. ..m.,d.......a.- ..1114,1•A,s.a...A. Ara.... -_ _. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proje , Type of spectio : // G✓� ktoV c.2 /VW Or Je‘/ Address: fl/o 6 5.8 e•YZ/ ,D, ati Date Called: Special Instructions: C Date W nted: --. 3 —o Requester: 1 Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: pejl- L/ V // G✓� ktoV c.2 /VW Or Je‘/ ::; )15 ?.d7■ , ./Z-7 Gam/& — 4/9,44,-.../ . /--. \ Date: y -5 -o7 60.00 REINSPECTION EE REG[UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: T INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. . CITY OF TUKWILA BUILDING DIVISION 11.' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3f7 Protect: � � LO► S" 0 /T / . a�, ]type of Inspection: . vL?. A �� Address: / r, /00 Date Cal ed: — —3 -v7 Special Instructions: Date Wanted: a.m. Requester: Phone No: pproved per applicable codes. El Corrections required prior to approval. COMMENTS: •Dk- r Date: 1=1$58.00 REINSp CTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD•' Retain a copy with permit INSPECTION NO PERMIT NO. CITY OF TUKWILA BUILDING DIVISION • '' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 ;5.2'.eg-i! 78 Project: C Type of Inspection: Address: 4te Called: Special Instructions: Date a ted: �--- U �._.:t' p.m. Requester: Phone �4.. - 71-4 " `.." --- Approved per applicable codes. [J Corrections required prior to approval. g COMMENTS: pix 0,444 ti /74a..i ThJV Inspector: Date' t° ❑$60.00 REINSPECTIOI FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Aoki. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00,1 kwila, WA 98188 (206)431 -36 INSPECTION RECORD Retain a copy with permit 1766,1-2 7c9 PERMIT NO. Project: C 10 SPE6N - SAe-r. Type of Inspection: �, Qdzit,10 WoR.LL Address: j1)05 SoC•,)+. Pyv Date Called: Special Instructions: . Date Wanted: 3 - L 7- uci a.m. cp•m1 Requester: Phone No: 3 Go— 8 7o- 3ze.r3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: l� — 6'vo4S NI -rte A.tro4-24iT,J M4 0 REINSPECTION FEE REQUIRED. rior to inspection, fee must be d at 6300 Southcenter Blvd., Suite 10p Call to schedule reinspection. Receipt No.: Date: • Page l of l Greg Villanueva - Old Spaghetti Factory - PG08 -278 From: Greg Villanueva To: bobm @thedussingroup.com Subject: Old Spaghetti Factory - PG08 -278 CC: Mike Cusick Hello Bob, Regarding the grease interceptor, I understand your concerns with the amount of grease that can be accounted for from the dishwasher however, Tukwila does not want the dishwasher routed to the interceptor. All other gray water needs to be routed to the interceptor. If you still have concerns, please contact Mike Cusick P.E. (Water /Sewer Engineer), at (206) 431 -2441 or email at mcusick @ci.tukwila.wa.us Also, our office will be closed 1/19, Monday. Thank you for your request for clarification. Greg Villanueva Development Engineer Public Works Department 206 - 431 -2442 office 206 - 571 -6321 cell 206 - 431 -3665 fax qvillanueva@ci.tukwila.wa.us • Cizy of f Tukwila Jim Haggerton, Mayor January 13, 2009 Department of Community Development Jack Pace, Director Bob Martin 0715 SW Bancroft St Portland OR 97239 RE: CORRECTION LETTER #1 Plumbing/Gas Piping Application Number PG08 -278 Old Spaghetti Factory —17100 Southcenter Py Suite 160 Dear Mr. Martin, This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Departments. The Building Department has no comments at this time. Public Works Department; Greg Villanueva at 206 - 431 -2442 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl xc: File No. PG08 -278 P:\Permit Center\Correction Letters\2008\P008 -278 Correction Ltr #2.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • CITY OF TUKWILA PUBLIC WORKS DEPARTMENT REVIEW COMMENTS DATE: January 13, 2009 PROJECT: Old Spaghetti Factory 17100 Southcenter Parkway, Suite 160 REVIEW NUMBER 2 PERMIT NO: PG08 -278 PLAN REVIEWER: Contact Greg Villanueva at (206) 431 -2442, if you have any questions regarding the following comments. Remove dishwasher connection to grease line and show connection to sanitary sewer (waste line). Route all gray water from sinks, floor drains, drains under garbage compactors to grease interceptor line. TRANSMITTAL Date: December 17, 2008 To: Allen Johannessen / Plans Examiner City of Tukwila Building Division - and - Greg Villanueva / Plans Examiner City of Tukwila Public Works Department Job: 0826 The Old Spaghetti Factory Restaurant 17100 Southcenter Parkway, Suite 160 Tukwila, WA 98188 Permit #: PG08 -278 Ifni Ali. I arc itec ure 2525 E Burnside Street Portland, Oregon 97214 503.226.3617 phone 503.226.3715 fax architects @seallp.com Mr. Johannessen, attached I am sending you the following clarifications and response to the Plumbing Review letter dated December 10th, 2008. Review Comment 1. Response: "Indicate on the plans specifically where all Backflow Prevention devices shall be installed. Provide the manufacturers specification and installation manual for each device. Identify those fixtures requiring back flow devices or indicate fixtures provided with their own back flow device." Backflow prevention for the tenant space supply is provided by the building shell and not part of the tenant improvement. See existing shell drawings for location of backflow preventer. Reverse pressure backflow preventer (BP -1 is being installed in the tenant space for the beverage carbonator. See floor plans (P2.01 and revised sheet P2.02) and plumbing fixture schedule (P0.11) for details. Installation manuals to be supplied by contractor per specifications. Review Comment 2. "Show back flow or vacuum breaker devices for mop sinks or similar and provide manufacturers specifications." Response: A vacuum breaker for the mop sink is included on the plumbing fixture schedule and is integral to the faucet. See revised drawing P0.11 (Delta 1, 12/17/08) Review Comment 3. "Identify where the fire- sprinkler riser connections shall be located. Provide the backflow device manufacturers specifications and installation instructions." Response: The fire sprinkler riser and backflow prevention was installed as part of the building shell. The existing service is being modified to match the tenant space floor plans as well as Code requirements. See shell drawings for exact location of fire sprinkler riser and backflow preventer. LLP Mr. Villanueva, attached I am sending you the following clarifications and response to the Public Works review letter dated December 9th, 2008. Review Comment 1. "Add abbreviation GI (dedicated grease line) to Plumbing Symbol List." Response: Added to revised sheet P0.01 (Delta 1, 12/17/08) Review Comment 2. "Remove dishwasher connection to grease line and show connection to sanitary sewer (waste line). Route all gray water from sinks, floor drains, drains under garbage compactors to grease interceptor line." Response: Waste lines revised on sheet P2.00 (Delta 1, 12/17/08) Thanks for your help and let me know if you need anything else. Sincerely, Jeff Hammond Project Manager Scott 1 Edwards Architecture 0 Chj' of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director December 10, 2008 Bob Martin 0715 SW Bancroft St Portland OR 97239 RE: CORRECTION LETTER #1 Plumbing/Gas Piping Application Number PG08 -278 Old Spaghetti Factory —17100 Southcenter Py Suite 160 Dear Mr. Martin, This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Public Works Departments. Building Department: Allen Johannessen at 206 - 433 -7163 if you have questions regarding the attached comments. Public Works Department; Greg Villanueva at 206 - 431 -2442 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, (� Bill Rambo Permit Technician encl xc: File No. PG08 -274 P:\Permit Center\Correction Letters \2008\PG08 -278 Correction Ltr /11.DOC wer AM!) Cnrrthrvntvr Rnnlvriard Snit," !Etna • Tukwila Waehinotnn OR1RR e Phnno• 7fA- A21_2A711 a ray. 9/)A_421_2AAG" I I Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: November 19, 2008 Project Name: Old Spaghetti Factory Permit #: PG08 -278 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Indicate on the plans specifically where all Backflow Prevention devices shall be installed. Provide the manufactures specification and installation manual for each device. Identify those fixtures requiring back flow devices or indicate fixtures provided with their own back flow device. (2006 UPC Section 603) 2. Show back flow or vacuum breaker devices for mop sinks or similar and provide manufactures specifications. (UPC 603.4.17) 3. Identify where the fire- sprinkler riser connections shall be located. Provide the backflow device manufactures specifications and installation instructions. (UPC 603.4.16) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. f ® • CITY OF TUKWILA PUBLIC WORKS DEPARTMENT REVIEW COMMENTS DATE: December 9, 2008 PROJECT: Old Spaghetti Factory 17100 Southcenter Parkway, Suite 160 PERMIT NO: PG08 -278 PLAN REVIEWER: Contact Greg Villanueva at (206) 431 -2442, if you have any questions regarding the following comments. 1. Add abbreviation GI (dedicated grease line) to Plumbing Symbol List. 2. Remove dishwasher connection to grease line and show connection to sanitary sewer (waste line). Route all gray water from sinks, floor drains, drains under garbage compactors to grease interceptor line. • koRfNlT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -278 DATE: 01 -28 -09 PROJECT NAME: OLD SPAGHETTI FACTORY SITE ADDRESS: 17100 SOUTHCENTER PY Original Plan Submittal X Response to Correction Letter # 2 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Division n ['Mir *s Structural Fire Prevention Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Xi Comments: Incomplete DUE DATE: 01-29-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route g Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 02-26-09 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 OPERMlT COON COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG08 -278 DATE: 12 -26 -08 PROJECT NAME: OLD SPAGHETTI FACTORY SITE ADDRESS: 17100 SOUTHCENTER PY, STE 160 Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: CI kwBuil. � g Division Publii Works f ��i Xi / 115,01 DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Fire Prevention Structural n Planning Division nPermit Coordinator n Complete Comments: Incomplete n DUE DATE: 12-30 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R TING: Please Route Structural Review Required ri No further Review Required ri REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01-27-09 Approved n Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: 1— 13-0? Bldg ❑ Fire ❑ Ping ❑ PW Staff Initials: Documents/routing slip.doc 2 -28 -02 PE `y MIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -278 DATE: 11 -06 -08 PROJECT NAME: OLD SPAGHETTI FACTORY SITE ADDRESS: 17100 SOUTHCENTER PY SUITE 160 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: I B i�ng P bl'c Wor 1� al-nks n 4 Fet,06 Fire Prevention n Planning Division Structural n Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 11 -11 -08 Not Applicable Permit Center Use Only _ • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: DUE DATE: 12 -09-08 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: • Permit Center Use Only ' • "G CORRECTION LETTER MAILED: l� LU'O6 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW Staff Initials: we Documents/routing slip.doc 2 -28-02 City of Tukwila Steven M Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tulcwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: / ❑ Response to Incomplete Letter # Plan Check/Permit Number: Response to Correction Letter # 2 DDB -27,g ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: 7?t dL faApJ 7 or Summary of Revision: i�/fiZp7N RECEVED ow O IJAN 2 8 2009 PERmo/ CtNTEk Phone Number: • •1 lSh c-c'a ' =e- •, e a _i i dJI iLA•1 �/ _ 4 / / -r , •! , i1 / Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: / f�- XEntered in Permits Plus on \applications\forms- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: ..,'. City 111 f Tukwila • Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Steve Lancaster, Director 1 REVISION SUBMITTAL 1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 12-23 -08 Plan Check/Permit Number: PG08 -278 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 cOF K►NILq ❑ Revision # after Permit is Issued DEC 2 61008 ❑ Revision requested by a City Building Inspector or Plans Examiner r+ERM►T CEv'EA Project Name: OLD SPAGHETTI FACTORY Project Address: 17100 Southcenter Py — Suite 160 Contact Person: JJ,FF 1-IAr 1Mor1O Phone Number: 5O - 22.4 - Summary of Revision: S 5g A TT AC C li ITO 11 -- r-t 1 Z re a 12ESPor4Sr LL < Sheet Number(s): PO -01 , P0. 11 I P2. oo j ► 2.0 2. "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: 3 Untitled Page 0 • General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip BUSH PLUMBING It MECHANICAL INC 3604568263 P 0 BOX 375 EAST OLYMPIA WA 98540 County THURSTON Business Type Corporation Parent Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601446057 ACTIVE BUSHPMI077JA CONSTRUCTION CONTRACTOR 4/1/1993 4/1/2010 BUSHPM *118JF PLUMBING UNUSED Business Owner Information Name Role Effective Date Expiration Date BUSH, JAMES R PRESIDENT 04/01/1993 Bond Amount BUSH, LINDSAY A SECRETARY 03/05/2002 634942 BUSH, KRIS A VICE PRESIDENT 04/01/1993 Date Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 CBIC 634942 04/01/2002 Until Cancelled Date Date $6,000.00 01/31/2002 1 CBIC 634942 04/01/1993 04/01/2002 $4,000.00 Insurance Information Page 1 of 2 https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License =BU SHPMI077JA 03/16/2009 Company Policy Effective Expiration Cancel Impaired Received Insurance Name Number Date Date Date Date Amount Date AMERICAN 8 FIRE AND BKA53201417 06/13/200806/13 /2009 $1,000,000.0004 /30/2008 CASUALTY https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License =BU SHPMI077JA 03/16/2009 WATER SERVICE CALCULATIONS PUBLIC GENERAL USE DESORPTION PLEUC QB+ERAL USE TOTAL UNTB (.75) HOT WATER 2 BAR SINK - -2" MIN. DRAIN BEYOND TRAP ARM 2 BAR SINK 2.00 4.00 3.00 5 HAND SINKS 2.00 10.00 7.50 1 DISHWASHER 0.00 0.00 4.00 2 ICE MAKERS 1.50 3.00 0.00 3 TEA MAKERS 1.50 4.50 0.00 3 COFFEE MAKERS 1.50 4.50 0.00 1 STEAMER 1.00 1.00 0.00 2 KETTLE 2.00 4.00 3.00 2 RANGE FAUCET 2.00 4.00 3.00 5 CARBONATOR 1.50 7.50 0.00 2 WATER FILLERS 1.50 3.00 0.00 1 DISH TABLE 1.50 1.50 0.00 2 BEVERAGE CENTER 1.50 3.00 0.00 2 4- COMPARTMENT SINK 4.00 8.00 6.00 2 PRE -RINSE SINK 4.00 8.00 6.00 3 KITCHEN SINK, DOMESTIC 1.50 4.50 3.38 8 LAVATORY 1.00 8.00 6.00 1 SERVICE SINK OR MOP BASIN 3.00 3.00 2.25 7 WATER CLOSET, 1.6 GPF, FLUSHVALVE 5.00 35.00 0.00 2 URINAL, 1.0 GPF, FLUSHVALVE 4.00 8.00 0.00 TOTAL FIXTURE UNITS 116.50 44.13 FLOW IN GPM 72 26 IRRIGATION FLOW IN GPM 0 TOTAL GPM REQUIRED 72 a. MINIMUM DAILY SERVICE PRESSURE 75 Psi b. STATIC HEAD LOSS .434 /Fr X 25 10.85 psi c. WATER METER PRESSURE DROP 2" 4.5 Psi d. BACKFLOW PREVENTER 2" 5 Psi e. PRESSURE REQUIRED AT FIXTURE 35 Psi PRESSURE AVAILABLE FOR FRICTION LOSS, a - b - c - d - e 19.65 psi TOTAL EQUIVALENT PIPE LENGTH 189 LENGTH X 1.25 236.25 ft MAXIMUM FRICTION LOSS PRESS. AVAIL. X 100' /EQUIV. LENGTH 8.317 psi SERVICE SIZE FROM SUB -METER 2" SANITARY DRAINAGE CALCULATIONS PUBLIC fiB+►L USE DEt3C PT ON PUBLIC GENERAL USE TOTAL UNTIE 2 BAR SINK - -2" MIN. DRAIN BEYOND TRAP ARM 2.00 4.00 1 DISHWASHER, DOMESTIC, INDEPENDENT DRAIN 4.00 4.00 2 LAVATORY, SINGLE 1.00 2.00 2 LAVATORY, SETS OF 2 OR 3 2.00 4.00 11 RECEPTOR, INC. WASTE, 3" TRAP 1.00 11.00 1 SERVICE SINK OR MOP BASIN, 3" TRAP 3.00 3.00 2 4- COMPARTMENT SINK 3.00 6.00 1 SINK, GENERAL, 2" TRAP 3.00 3.00 2 URINAL 2.00 4.00 7 WATER CLOSET, 1.6 GPF, FLUSHOMETER VALVE 4.00 28.00 5 PREP SINKS 3.00 15.00 5 HAND SINKS 2.00 10.00 TOTAL FIXTURE UNITS 94.00 FILE: 0497P0.01.DWG - P0.01 I EDIT: 12/23/2008 3 :26 PM BY VICTORIAH I PLOT: 12/23/2008 3 :46 PM BY QUINLAN BELOG GAS CALCULATIONS FIXTUFE DESCRPTION KIT4 F 1 EOUI NENT CONVECTION OVEN BRAISING PAN FLOOR KETTLE RANGE (COUNTER TOP) GRIDDLE CHEESE MELTER CONVECTION OVEN PASTA COOKER MECHANCAL EOUPWENT AC -1 ROOF TOP UNIT AC -2 ROOF TOP UNIT AC -3 ROOF TOP UNIT AC -4 ROOF TOP UNIT AC -5 ROOF TOP UNIT AC -6 ROOF TOP UNIT MAU -1 MAKE UP AIR UNIT PLUMBING EAUPNENT WH -1 DOMESTIC WATER HEATER WH -2 DOMESTIC WATER HEATER 204 WATER BOOSTER HEATER NO. OF BTU/Hi TOTAL F9)(T. I+PUT gruff l 1 40,000 1 144,000 1 15,000 1 80,000 1 40,000 1 40,000 1 115,000 2 150,000 40,000 144,000 15,000 80,000 40,000 40,000 115,000 300,000 1 1 1 1 1 1 233,000 198,000 189,000 99,000 45,000 45,000 176,000 /1\ 233,000 198,000 189,000 99,000 45,000 45,000 176,000 1 199,000 199,000 1 199,000 199,000 1 199,000 199,000 SIZING BASED ON 2007 MECHANICAL SPECIALTY CODE 2 PSI SUPPLY PRESSURE WITH 1 PSI PRESSURE DROP 147 FEET DEVELOPED LENGTH 3 2 -1 /2" 2" 1 1/2" 1 1/4" 1" 3/4" 1/2" 22,900 CFH 13,000 CFH 8,130 CFH 4,220 CFH 2,820 CFH 1,370 CFH 751 CFH 372 CFH R'. WCO Co QD VTR ;o+ 180' 180'R 2#G G D PLUMBING SYMBOL LIST VALVES VALVE, GENERAL CHECK VALVE QUARTER TURN VALVE GLOBE VALVE PRESSURE REDUCING VALVE BALANCING VALVE FITTINGS PIPE RISE PIPE DROP TEE UP ON PIPE TEE DOWN ON PIPE CONTINUATION CAP HOSE BIBB WALL CLEANOUT FLOOR CLEANOUT FLOOR DRAIN FLOOR SINK VENT THROUGH ROOF PIPING SYSTEMS COLD WATER PIPING 140' HOT WATER PIPING 140'R HOT WATER PIPING 180' HOT WATER PIPING 180'R HOT WATER PIPING 2# PSI GAS PIPING GAS PIPING, 6 IN. W.C. CONDENSATE PIPING BEVERAGE LINE FCW FILTERED COLD WATER SANITARY PIPING BELOW GRADE OR FINISHED FLOOR WASTE PIPING ABOVE GRADE WITH DRAIN PAN SANITARY PIPING ABOVE GRADE OR FINISHED FLOOR GI GREASE WASTE TO OUTSIDE INTERCEPTOR SANITARY VENT PIPING PIPING BELOW FLOOR ABBREVIATIONS AFF ABOVE FINISHED FLOOR BFP BACKFLOW PREVENTER BFF BELOW FINISHED FLOOR CD CONDENSATE DRAIN CONT. CONTINUATION CV CHECK VALVE CW COLD WATER DIA DIAMETER FT FEET GAL GALLONS GPF GALLONS PER FLUSH GPH GALLONS PER HOUR GPM GALLONS PER MINUTE HD HEAD HP HORSE POWER HW HOT WATER HWR HOT WATER RETURN ID INSIDE DIAMETER IE INVERT ELEVATION IN INCHES LBS. POUNDS MIN MINIMUM N/A NOT APPLICABLE NIC NOT IN CONTRACT NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER PD PRESSURE DROP PRV PRESSURE REDUCING VALVE PSI POUNDS PER SQUARE INCH QTY QUANTITY SF SQUARE FEET SOV SHUT OFF VALVE SP STATIC PRESSURE TP TOTAL PRESSURE V VENT W.C. WATER COLUMN W/ WITH W/O WITHOUT A. CONDITIONS SHOWN ON THE PLANS RELATIVE TO THE WORK TO BE PERFORMED ARE BASED ON THE BEST INFORMATION AVAILABLE BUT ARE SUBJECT TO VERIFICATION. VERIFY LOCATIONS AND ELEVATIONS OF UTILITIES TO BE CROSSED OR CONNECTED. CORRECT DEFICIENCIES CAUSED BY FAILURE TO PERFORM SUCH VERIFICATIONS AT NO EXPENSE TO OWNER. IMMEDIATELY NOTIFY ARCHITECT AND ENGINEER OF CONDITION IN CONFLICT WITH THE PLANS. B. C. PROVIDE PIPING, EQUIPMENT, AND MATERIALS IN ACCORDANCE WITH APPLICABLE PLUMBING CODE REGULATIONS AND STANDARDS. AUTHORITIES HAVING JURISDICTION, AND AS OTHERWISE RECOMMENDED OR DIRECTED BY MANUFACTURERS. PROVIDE GAS SHUTOFF VALVES, PRESSURE REGULATORS AND UNIONS (OR CODE APPROVED APPLIANCE CONNECTORS) AT CONNECTIONS TO ALL GAS -FIRED EQUIPMENT. PROVIDE REGULATOR RELIEF VENT PIPING TO ATMOSPHERE WHERE REQUIRED BY CODE. D. COORDINATE INSTALLATION OF PIPING BELOW AND ABOVE GRADE WITH STRUCTURAL COMPONENTS AND OTHER SYSTEM INSTALLATIONS. E. PROVIDE CLEANOUTS FOR SANITARY WASTE SYSTEMS WHERE SHOWN AND AS OTHERWISE REQUIRED BY CODE. F. DO NOT SCALE THESE DRAWINGS. OBTAIN SPECIFIC INFORMATION CONCERNING DIMENSIONS, LOCATIONS AND REQUIREMENTS OF FIXTURES, DRAINS, EQUIPMENT, ETC. FROM KITCHEN CONSULTANT FURNISHED FIXTURE CUTSHEETS /FIXTURE LAYOUT PLANS AND ARCHITECTURAL DRAWINGS. G. LOCATE ALL VALVES FOR SERVICE ACCESSIBILITY. VALVES INSTALLED ABOVE CEILINGS SHALL BE WITHIN 18" OF CEILING. H. NO WATER, SEWER, GAS OR VENT PIPING SHALL BE INSTALLED WITHIN ANY INSULATED COOLER OR FREEZER WALL. I. INSTALL ALL OVERHEAD PIPING AS CLOSE TO STRUCTURE AS POSSIBLE IN AREAS WITH EXPOSED ROOF STRUCTURE. BVISIUNS � e to the scope No changes shall be prior made approval at of work without p IDty` +soon. Tukwila Building tan submittal Revisions will require a new P NOTE: d may include additional plan review tees. and NOTES J. FURNISH AND INSTALL ALL VALVES, TRAPS, STRAINERS, BACK FLOW PREVENTERS, ETC. NOT FURNISHED BY EQUIPMENT SUPPLIER, BUT NEEDED FOR PROPER EQUIPMENT OPERATION. K. ALL FLOOR SINKS AND OTHER INDIRECT WASTE RECEPTORS SHALL BE LOCATED WHERE THEY ARE READILY ACCESSIBLE FOR INSPECTION AND CLEANING. L. REFER TO KITCHEN CONSULTANT DRAWINGS (K) FOR EXACT LOCATION OF ALL FIXTURES DRAINS AND EQUIPMENT AND EXACT DESCRIPTION AND ROUGH -IN REQUIREMENTS OF ALL KITCHEN EQUIPMENT BEING CONNECTED TO. M. SHUTOFF VALVES TO BE INSTALLED IN ALL WATER AND GAS PIPING AT LOCATIONS SHOWN, AND WHERE NEEDED TO PROVIDE ADEQUATE ZONING FOR SERVICING PIPING AND EQUIPMENT. PROVIDE ACCESS PANELS IF CEILING AND STRUCTURAL CONDITIONS DO NOT ALLOW NORMAL ACCESS. COORDINATE EXACT TYPE AND LOCATION WITH OWNER AND GENERAL CONTRACTOR PRIOR TO ROUGH -IN. N. LOCATE ALL VTR A MINIMUM OF 1O' -0" FROM OUTSIDE AIR OPENINGS OF ROOFTOP HVAC EQUIPMENT. 0. ALL FLOOR DRAINS AND FLOOR SINKS SHALL HAVE TRAP PRIMER CONNECTIONS IN ACCORDANCE WITH THE STANDARDS OF LOCAL AUTHORITIES. P3.01 FIL--E COPY eia Permit No.r .et 1 Plan review approval is subject to error and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fie Cop a conditions is acknowledged: BY- Date: SEPARATE PERMIT REQUIRED FOR: L!? Mechanical (Electrical 0 Plumbing 0 Gas Piping City of Tukwila BUILDING DIVISION, qty O tlbkwIIel BUILDING DIVISION DRAWING INDEX P0.01 LEGEND, SYMBOLS, DRAWING INDEX - PLUMBING P0.11 SCHEDULES - PLUMBING P2.00 FIRST FLOOR PLAN - PLUMBING - WASTE /VENT P2.01 FIRST FLOOR PLAN - PLUMBING - WATER /GAS P2.02 SECOND FLOOR PLAN - PLUMBING P2.03 ROOF PLAN - PLUMBING DETAILS - PLUMBING CORRECTION LT R# 6 ru b CODE COMPLIANCE APPROVED FEB 2 0 009 Of Tukwila WARDING DIVISION R CEIV D CITY OF TU DEC 2 6 2008 PERMIT CENTER ?koS INTERFACE E N G I N E E R I N G Contact Victoria Haynes Project 2008 -0497 708 S.W. 3RD AVE., SUM 400, PORTLAND, OR 97204 PHONE 503.382.2266 TAX 503.382.2262 PLUMBING Job No: File Name: Date: Rev: arc nI;.Ire 2525 Ent - nunde t4. Portland, OR 97214 503.2a;,3617 phone 503 'M.3715 fax ue. aiip,c0ni THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWILA, WASHINGTON LEFT LEGEND, SYMBOLS, DRAWING INDEX 0826 12/17/08 CITY REVIEW COMMENTS Sheet No: P0.01 KITCHEN FIXTURE CONNECTION SCHEDULE SYMBOL FIXTURE CONNECTION W CONNECTION SIZE CW REMARKS GAS OW HW W IND. W V a ICE MAKER /BIN - -- 1/2" - -- - -- I.W. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER a ICE MAKER /BIN - -- 1/2" - -- - -- LW. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER HB -1 SOILED DISH TABLE - -- - -- - -- - -- LW, - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER a PRE -RINSE ASSEMBLY - -- 1/2" 1/2" - -- - -- - -- 1/2" 8 DISHWASHER - -- - -- 3/4" ___ I.W. ___ ROUTE DRAIN TO INDIRECT WASTE RECEIVER. CONNECT TO REMOTE BOOSTER HEATER. a 4- COMPARTMENT SINK - -- - -- - -- 1 -1 /2' - -- - -- WITH PRE -RINSE SINK AND SCRAP BUCKET 16 BIG FLOW FAUCETS (2 SETS) - -- 3/4" 3/4" - -- - -- - -- -- -- a PRE -RINSE ASSEMBLY - -- 1/2" 1/2" - -- - -- - -- 20 FLOOR TROUGH - -- - -- - -- 4" - -- - -- 2" a MOP SINK _ -_ _ -- _ -- 1 -1/2" -_- - -- PROVIDE MS -1 / \ 0 SERVICE FAUCET ___ 1/2" 1/2" ___ ___ ___ - -- a HAND SINK FAUCETS (4 SETS) - -- 1/2" 1/2" - -- - -- - -- INSTALL WITH MV -2 28 HAND SINK (4) - -- - -- - -- 1 -1/2" - -- - -- a PREP SINK TABLE ----° - -- - -- - -- I.W. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER 34 PREP SINK FAUCETS - -- 1/2" 1/2" - -- - -- - -- 40 FLOOR TROUGH - -- - -- - -- a CONVECTION OVEN W /WORKTOP 3/4" - -- - -- - -- - -- - -- 40 MBH 46 BRAISING PAN - -- - -- - -- - -- - -- - -- ROUTE DRAIN TO INDIRECT DISCHARGE AT TROUGH a KETTLE FILLER FAUCET (2) - -- 1/2" 1/2" - -- - -- - -- 48 KETTLE STAND - -- - -- - -- - -- I.W. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER 49 FLOOR KETTLE 1/2" ___ 15 MBH. ROUTE DRAIN FLOOR TO TROUGH INDIRECT DISCHARGE AT Go PASTA TABLE W/ SINK - -- - -- - -- 1 -1/2" - -- - -- 58 BIG FLOW FAUCET - -- 3/4" 3/4" - -- - -- - -- 61 KETTLE STAND - -- - -- - -- ° -- LW. - -° ROUTE DRAIN TO INDIRECT WASTE RECEIVER 62 DOUBLE JOINT FAUCET - -- 1/2" 1/2" - -- - -- -- - 64 RANGE (COUNTER TOP) 3/4" - -- - -- - -- - -- - -- 80 MBH 65 GRIDDLE 3/4" - -_ - -- - -- - -- - -- 40 MBH 69 CHEESE MELTER 3/4" - -- - -- - -- - -- - -- 40 MBH . CONVECTION OVEN 3/4" - -- - -- - -- - -- - -- 115 MBH 82 COOLER EVAPORATOR COIL - -- - -- - -- - -- LW. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER 88 FREEZER EVAPORATOR COIL - -- - -_ ___ ___ I,W, - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER 93 BREAD WARMER WELL - -- - -- - -- - -- I.W. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER 100 HOT WELLS - -- - -- 1/2" - -- I.W. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER (101 HOT WELLS - -- - -- 1/2" - -- LW. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER 106 PASTA COOKER (2) 3/4" 1/2" 1/2" - -- I.W. - -- 150 MBH (EA.) 120 DBL JOINT FAUCET - PASTA - -- - -- 1/2" - -- - -- - -- SEE FIXTURE SCHEDULE S -1. 126 DIPPER WELL ASSEMBLY - -- - -- 1/2" - -- I.W. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER SOUP WELL (2) - -- - -- - -- - -- LW. _ -_ ROUTE DRAIN TO INDIRECT WASTE RECEIVER TEA BREWER 139 SODA DISPENSER - -- 1/2" ___ ___ _ -- ___ 140 LEMONADE DISPENSER ---- 1/2" --- ___ ___ ___ 0 COFFEE MAKER (2) - -- 1 /2" - -- - -- - -- - -- 143 SINK - -- - -- - -- 1 -1/2" - -- - -- 144 SINK FAUCET - -- 1/2" 1/2" ___ ___ ___ 150 CARBONATORS - -- 1/2" - -- - -- - -- - -- iD DRAIN BOARD - -- - -- - -- - -- LW. - -- 4 ICE BIN ° °° °- ° °° _ °° I.W. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER 4- COMPARTMENT SINK - -- - -- - -- 1 -1/2" - -- - -- a 4 -COMP. SINK FAUCET - -- 1/2" 1/2" - -- - -- ___ 156 DOUBLE JOINT FAUCET - -- 1/2" 1/2" - -- - -- - -- 159 HAND SINK - -- - -- - -- 1-1/2" - -- - -- 160 SINK FAUCET - -- 1/2" 1/2" - -- - -- - -- INSTALL WITH MV -2 161 BLENDER STATION W /DUMP (2) - -- - -- - -- - -- I.W. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER 162 BLENDER SINK FAUCET (2) - -- 1/2" 1/2" - -- - -- - -_ 169 _ ICE BIN - - - -- - -- - -- I.W. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER e DRINK RAIL - -- - -- - -- - -- LW. - -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER 070 SINK -- - ___ - -. 1 -1/2" ___ _ - a SINK FAUCET - -- 1/2" 1/2" - -- - -- - -- 180 HOT WELLS - -- - -- - -- - -- LW. -- - ROUTE DRAIN TO INDIRECT WASTE RECEIVER 184 LEMONADE DISPENSER - -- 1 /2" - -- - -- - -- - -- 186 TEA BREWER - - -- 1 /2" - -- - -- - -- - -- 187 COFFEE MAKER - -- 1 /2" - -- - -- - -- - - -- 188 SODA DISPENSER 190 REMOTE CARBONATORS (3) - -- 1 /2" - -- - -- - -- - -- 199 BEER COOLER EVAPORATOR COIL - -- - -- - -- - -- I.W. _ -- ROUTE DRAIN TO INDIRECT WASTE RECEIVER 204 BOOSTER HEATER 1" _ -- - -- ___ ___ ___ 200 MBH (WITH RE- CIRCULATION KIT) PLUMBING FIXTURE SCHEDULE SYMBOL DESCRIPTION CONNECTION W V CW HW ET -1 EXPANSION TANK: WELDED STEEL CONSTRUCTION, DIAPHRAGM TYPE, PRE- PRESSURIZED, 4.8 GALLON VOLUME, 3 GALLON ACCEPTANCE. AMTROL ST -12 (ASME) - -- - -- 1" - -- FD -1 FLOOR DRAIN: CAST -IRON BODY WITH ADJUSTABLE ROUND POLISHED NICKEL BRONZE TOP. STRAINER DIAMETER 6 ". VANDAL -PROOF SCREWS. PROVIDE WITH TP -1. J.R. SMITH 2005 -A. SEE DWGS. SEE DWGS - -- - -- FS -1 FLOOR SINK: 12 -1/2" SQUARE TOP, 8" DEEP, HEAVY CAST -IRON WITH ACID RESISTANT COATING INTERIOR, ALUMINUM DOME BOTTOM STRAINER, PRIMED. COMMERCIAL ENAMEL NO. 906 -6 (NOTE: VERIFY GRATE REQUIREMENTS WITH KITCHEN CONSULTANT PLANS) 3" 2 "___ _ -_ FS-2 FLOOR SINK: 12 -1/2" SQUARE TOP, 10" DEEP, HEAVY CAST -IRON WITH ACID RESISTANT COATING INTERIOR, ALUMINUM DOME BOTTOM STRAINER, PRIMED. COMMERCIAL ENAMEL NO. 906 -10 (NOTE: VERIFY GRATE REQUIREMENTS WITH KITCHEN CONSULTANT PLANS) 3" 2" HB -1 HOSE BIBS, TRASH ROOM: ACORN 8156 _ -- - -- 3/4" 3/4" L -1 LAVATORY: WALL HUNG, VITREOUS CHINA, 20 "x18 ", FRONT OVERFLOW, SOAP DEPRESSION, FAUCET HOLES ON 4" CENTERS. CONCEALED ARMS, AMERICAN STANDARD 0355.012 "LUCERNE" FITTINGS: 1 -1/4" x 1 -1/2" P -TRAP. SUPPLIES AND STOPS. CARRIER: FLOOR MOUNTED WITH CONCEALED ARMS, J.R. SMITH, AS APPLICABLE. FAUCET:INFRARED SENSOR, 120 VAC/ 6 VDC PLUG -IN TRANSFORMER (SLOAN SFP -6), 4" CENTERS, 3/8" O.D. COPPER TUBE INLETS, VANDAL - RESISTANT 0.5 GPM AERATOR, NO LIFT ROD HOLE, POLISHED CHROME FINISH GRID STRAINER. INSTALL WITH MV -2 SLOAN EBF -650, CHROME FINISH 1-1/2" 1-1/2" 1/2" 1/2" L -2 LAVATORY: COUNTERTOP, VITREOUS CHINA, 20 IN. BY 17 IN, OVAL ADA COMPLIANT, FRONT OVERFLOW, SELF - RIMMING, 4 IN. CENTERS. AMERICAN STANDARD 0476.028 "AQUALYN" FITTINGS: 1 -1/4" x 1 -1/2" P -TRAP. SUPPLIES AND STOPS. ., , . - - 1-1/2" - 1-1/2" 1/2" 1/2" MS -1 MOP SINK: FLOOR MOUNTED, 28 IN, X 28 IN., CORNER TYPE, ACID - RESISTANT, MOLDED STONE, MUSTEE 63M FAUCET: HOSE -END SPOUT TYPE WITH INTEGRAL VACUUM BREAKER, ADJUSTABLE ARMS WITH INTEGRAL STOPS, AND WALL BRACE. CHROME. 2" 1 -1/2" 1/2" 1/2" MV -2 MIXING VALVE: 120'F INLET, 110'F DELIVERY, POINT OF USE TYPE. ROUGH CHROME FINISH, 1/2" NPT POWERS E480 -01 - -- - -- 3/4" 3/4" CP -1 HOT WATER RECIRCULATING PUMP: BELL AND GOSSETT "LITTLE RED" #LR -15 WITH BRONZE BODY. 120V,1PH, 1/12 HP MOTOR. - -- - --- - -- 3/4" CP -2 HOT WATER RECIRCULATING PUMP: BELL AND GOSSETT "LITTLE RED" #LR -15 WITH BRONZE BODY. 120V,1PH, 1/12 HP MOTOR. - -- - -- -- ---- 3/4" PF -1 ,.,�`�_. BP -1 POT FILLER FAUCET: BRASS BODY, SINGLE WATER INLET, 18" DOUBLE - JOINTED SPOUT, QUARTER -TURN RENEWABLE CARTRIDGE, POLISHED CHROM FINISH. CHICAGO 515 -CP - -- - -- -- -- 1/2" REDUCED PRESSURE BACKFLOW PREVENTER: CARBONATOR, STEAMER: __- - -- 1/2" ___ A TP -1 TRAP PRIMER. PPP PR -500, "PRIME RITE" - -- - -- qw- 1/2" ___ U -1 URINAL: SIPHON JET, VITREOUS CHINA, WALL MOUNTED, 3/4 IN. TOP SPUD. MOUNTING HEIGHT STANDARD. KOHLER K- 5016 -ET "DEXTER" FLUSH VALVE: 1.0 GAL. PER FLUSH, TOP SPUD. SLOAN OPTIMA PLUS 8186 -1 (INFRARED SENSOR /BATTERY) CARRIER: FLOOR MOUNTED. J.R. SMITH 0600 SERIES URINAL SUPPORT WITH SUPPORTING STUDS AND BOTTOM BEARING PLATE. 2" 1 -1/2" 3/4" _ -_ U -2 URINAL: SAME AS U -1 ACCEPT MOUNTED AT SPECIAL MOUNTING HEIGHT FOR ADA COMPLIANCE. 2" 1 -1/2" 3/4" __- WH -1 WATER HEATER: GAS FIRED, 95% EFFICIENCY, AIR INTAKE AND EXHAUST, WH -2 199 MBH INPUT, 230 GPH RECOVERY AT 100'F TEMPERATURE RISE, DRAIN VALVE, T &P VALVE, AQUASTAT AT CIRCULATION PUMP, W /INTERMITTENT ELECTRONIC IGNITION, 115V, 1 PH, 60Hz, 100 GAL. FACTORY INSULATED, 1,424LBS. (WET), ASME RATED STORAGE TANK. PIPING SHALL BE PER MANUFACTURER'S RECOMMENDATION. A.O SMITH 8TH 199 - -- - -- 1 -1/2" 1 -1/2" WC -2 WATER CLOSET: SAME AS WC -1 BUT ADA MOUNTING HEIGHT. KOHLER, K -4330 3" 2" 1" - -- PLUMBING EQUIPMENT SCHEDULE SYMBOL DESCRIPTION ELECTRICAL CP -1 HOT WATER RECIRCULATION PUMP: BELL AND GOSSET "LITTLE RED" #LR -15BWR WITH BRONZE BODY. 1/12 HP 120 V 1 PHASE WH -1 WH-2 WATER HEATER: GAS - FIRED, 95% EFFICIENCY, AIR INTAKE AND EXHAUST, DRAIN VALVE, T & P VALVE, AQUASTAT AT CIRCULATION PUMP W /ELECTRONIC IGNITION 100 GAL. FACTORY INSULATED, 1424LBS. (WET), ASME RATED STORAGE TANK, 199 BTUH INPUT, 230 GPH AT 100'F RISE. A.O. SMITH, BTH -199 115 V 1 PHASE 60 Hz. FILE: 0497P0.11.DWG - P0.11 I EDIT: 12/23/2008 3:30 PM BY VICTORIAN I PLOT: 12/23/2008 3 :47 PM BY QUINLAN BELOG Rai WNW t-u COMPLIPICE AP! •` * °VIE FEB 2 0 2E fl9 ?GO8 z78 1 ONION C4S$ C°nl! A DEC 2 6 /NH PERMIT CENTER 4 INTERFACE ENGINEERING Contact Victoria Haynes Project 2008 -0497 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PIIONE 503.382.2266 TAX 503.382.2262 P elc arc ffiecture 2525 t aut N.. rro,t;o Portland, OR 57214 503 996 3617 prhon 503,225.3715 fQ x THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWILA, WASHINGTON SCHEDULES — PLUMBING Job No: 0826 File Name: Date: 12/17/08 Rev: CITY REVIEW COMMENTS Sheet No: P0.11 :4 140 142 1.101 J; 3» .................... ES -1 WC L �__ 12 " ' 1: ; FILE: 0497P2.00.DWG — P2.00 EDIT: 1/22/2009 4: 30 PM BY TODDS I PLOT: 1/22/2009 5: 09 PM BY TODD SI•4OOTE 3" ' I , !i i! a 1 FR--1 FS -2 SCALE: 1/4 8 4 ES -2 3 " r -- a - 2" .:..... ....... ........................ FIRST FLOOR PLAN -PLUMBING - WASTE /VENT r: •.. .. 2 " Apo IWCO 2 " Of "if fi r -4; 4 1 _gip ♦ 4 , ' I, I I D -1 s �� �� l t t 4 1 GI —3 3 FS--2 -3 1: D 0 0 4 E 0 0 0 10 SHEET KEYNOTES INSTALL FS -1 OR FS-2 AS INDICATED AND PROVIDE INDIRECT WASTE PIPING FROM EQUIPMENT TO AIR GAP DISCHARGE. VERIFY EXACT SIZE AND LOCATION OF FLOOR SINK AND INDIRECT DRAIN WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH —IN, ROUTE PVC PIPING BELOW SLAB FOR FUTURE INSTALLATION OF BEVERAGE /BEER TUBING BY LOCAL VENDOR. INSTALL PVC PIPING USING EXTRA LONG SWEEP ELBOWS. COORDINATE EXACT ROUTING WITH ELECTRICAL, MECHANICAL, STRUCTURAL. SEE 3/P3.01 PROVIDE INSULATED REFRIGERATION COIL CONDENSATE DRAIN PIPING AND COORDINATE ALL NECESSARY WALL PENETRATIONS WITH EQUIPMENT SUPPLIER. ROUTE SAME SIZE AS CONNECTION SIZE. SLOPE TO DISCHARGE LOCATIONS AS REQUIRED. ROUGH —IN WASTE AND VENT PIPING AS REQUIRED FOR CONNECTION TO OWNER SUPPLIED /CONTRACTOR INSTALLED FIXTURE. VERIFY ROUGH --IN REQUIREMENTS WITH KITCHEN CONSULTANTS FIXTURE SCHEDULE. SEE SHEET P1.0. ISLAND VENT FIXTURE PER PLUMBING CODE. OFFSET FOOT VENT BELOW FLOOR AS SHOWN. SEE DETAIL 7/P3.01, ROUTE VENT PIPING BELOW FLOOR, THEN UP IN WALL AS SHOWN. ROUTE DRAIN SAME SIZE AS OUTLET FROM MAKE UP AIR UNIT DOWN THROUGH ROOF AND ROUTE IN CEILING TO FLOOR SINK AS SHOWN, 3 INCH WASTE PIPING UP, SEE 1/P2.02 FOR CONTINUATION. 2 INCH WASTE PIPING UP. SEE 1/P2.02 FOR CONTINUATION. ROUTE WASTE FROM KITCHEN /BAR EQUIPMENT TO INDIRECT DISCHARGE AT FLOOR SINK. CONNECT NEW WASTE PIPING TO EXISTING WASTE PIPING BELOW FLOOR, PROVIDE DRAIN PAN UNDER WASTE PIPING ABOVE FOOD PREP AREAS AND SLOPE BACK TO RISER LOCATION. SEE 1/P3.01. VENT PIPING UP, SEE 1/P2.02 FOR CONTINUATION. Vial lat) rurt. CO 1 E COMPLIANCE. APP ' VED FEB ?0 NI City Onuldda I.la NGOMSION FGOB, 279 AV-MLA JAN 2 8 2009 PERMIT CENTER INTERFACE w ENGINEERING Contact Victoria Haynes Project 2008 -0497 708 8.W. ;RD AVE., SU1TE 400, PORT.L.ANI3, OR 97204 .PHONE 503.382.2266 FAX 503.382.2262 Rev: THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWLA, WASHINGTON FIRST FLOOR PLAN PLUMBING WASTE/VENT Job No: 0826 File Name: Date: 01/22/09 CITY REVIEW COMMENTS CITY REVISIONS CORRECTION LTR# Sheet No: P2.00 GI \. .. "< „ Nom. 111111 (tiiiiH11111 E111111i11 1111 3 Il ` 4r 1 Il fl 1111 __1111 111112466 1111 l lffIN111 11111f 111 11i 1111111 X1.11 € 1111 I'111111C1f111L11 IlIf1(111111 1244811 i[111[11111111 24.361}1E, i ;( 1[l _ 111111iI[lll E11`llil 11 111[111 811111[ lE ;s FS -2 O FS -1 WCO GI PP in I L FS -1 / t t // // ,, ' . N • . ` \. ".. "\ / / / \ ." \. "\ ° \ Fr .. I, ( f WCO 3" FILE: 0497P2.00.DWG - P2.00 I EDIT: 12/23/2008 2 :38 PM BY VICTORIAH I PLOT: 12/23/2008 3 :47 PM BY QUINLAN BELOG ES -1 i am( H ED -1 FS -2 0 1 FIRST FLOG 0 2' 4' SCALE: 1/4"=1'-0" 8' FS -2 I H 1 CO r rr L iftts\ 1 PLAN - PLUMBING-WASTE/VEN WCO CL ( WC 4" 2" 3" FS- 2 (TYP.) FS-2 n 1 6"1 4 GI F FS -2 T r --- -_ _ WCO (TYP. 13) FS- 2 ES- 2 1 SHEET KEYNOTES N, U 10 11 12 13 INSTALL FS -1 OR FS -2 AS INDICATED AND PROVIDE INDIRECT WASTE PIPING FROM EQUIPMENT TO AIR GAP DISCHARGE. VERIFY EXACT SIZE AND LOCATION OF FLOOR SINK AND INDIRECT DRAIN WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH -IN. ROUTE PVC PIPING BELOW SLAB FOR FUTURE INSTALLATION OF BEVERAGE /BEER TUBING BY LOCAL VENDOR. INSTALL PVC PIPING USING EXTRA LONG SWEEP ELBOWS. COORDINATE EXACT ROUTING WITH ELECTRICAL, MECHANICAL, STRUCTURAL. SEE 3/P3.01 PROVIDE INSULATED REFRIGERATION COIL CONDENSATE DRAIN PIPING AND COORDINATE ALL NECESSARY WALL PENETRATIONS WITH EQUIPMENT SUPPLIER. ROUTE SAME SIZE AS CONNECTION SIZE. SLOPE TO DISCHARGE LOCATIONS AS REQUIRED. ROUGH -IN WASTE AND VENT PIPING AS REQUIRED FOR CONNECTION TO OWNER SUPPLIED /CONTRACTOR INSTALLED FIXTURE. VERIFY ROUGH -IN REQUIREMENTS WITH KITCHEN CONSULTANTS FIXTURE SCHEDULE. SEE SHEET P1.0. ISLAND VENT FIXTURE PER PLUMBING CODE. OFFSET FOOT VENT BELOW FLOOR AS SHOWN. SEE DETAIL 7/P3.01. ROUTE VENT PIPING BELOW FLOOR, THEN UP IN WALL AS SHOWN. ROUTE DRAIN SAME SIZE AS OUTLET FROM MAKE UP AIR UNIT DOWN THROUGH ROOF AND ROUTE IN CEILING TO FLOOR SINK AS SHOWN. 3 INCH WASTE PIPING UP. SEE 1/P2.02 FOR CONTINUATION. 2 INCH WASTE PIPING UP. SEE 1/P2.02 FOR CONTINUATION. ROUTE WASTE FROM KITCHEN /BAR EQUIPMENT TO INDIRECT DISCHARGE AT FLOOR SINK. CONNECT NEW WASTE PIPING TO EXISTING WASTE PIPING BELOW FLOOR. PROVIDE DRAIN PAN UNDER WASTE PIPING ABOVE FOOD PREP AREAS AND SLOPE BACK TO RISER LOCATION. SEE 1 /P3.01. VENT PIPING UP. SEE 1/P2.02 FOR CONTINUATION. G CODE COMP LO PROVED FEB 2.0 •lifjl" Ca alb i i U 0 SION 8 - z78 04 DEC 2 6 2008 PERMIT CENTER INTERFACE E N G I N E E R I N G Contact Victoria Haynes Project 20080497 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PHONE 503.382.2266 FAX 503.382.2262 arc I l ' I r Date: Rev: 2525 t st Burnuide �y €. Portland, OR 07214 603.226.3e617 phono s03.226,3'71> fi.m THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWILA, WASHINGTON FIRST FLOOR PLAN PLUMBING WASTE /VENT Job No: File Name: 0826 MEM 12/17/08 / \ CITY REVIEW COMMENTS LL_P Sheet No: P2.00 r- EXSITING 2" DOMESTIC COLD WATER LINE I I I ±H 1 111 h-} N j[l11'lli011[ 1 1]11 1 1 `1111' IlL111 1119'If 1111 111111 111ll(...11E1111111 Il' 1 1111111 011111=' -1 11111] 110111111 1111' 4 I )( [It]fIJIILI111 [C'1`lll, 1111 1 1 [1G[rJ11L[1111Iffli1!11!Ll,1'l11 f1'l1l_ _ 1 ���orC }1[[111 ij[j (111 1111111111 11[I 1' li 111117111[ • C1111 1111[ 1.111,1 [ I1111111I�� 1111111111V11_,1111 � �1 1 � 1 I I]L[ �ilIII, �_.. � 0111�:I 1�1 [1lV�. l�l1[ I + 1 1-1/2" (2633 MBH) FILE: 0497P2.01.DWG — P2,01 I EDIT: 10/31/2008 1:40 PM BY RACHELD I PLOT: 10/31/2008 3:35 PM BY RACHEL DEFOURI 1 -1/4" 1/2" IMO SCALE: 1/4"=V-0" 144 MBH 40 MBH 0 80 MBH [11 1111'1111,11111 I' � LI 1 11 1 1/2" 1/2" 1/2" -v vl tA 2 1-1/2" 1/2" i co 1-1/4" t 1 FIRST FLOOR PLAN - PLUMBING -WATER /GAS 0 2' 4' 8' '. 15 MBH 1/2" n EL 1/2" 1 'I 2" 3/4" 1/2" 3/4 1/2" 3/4 ' 0Q uc � 0 8 [-- J.. `i 3 SHEET KEYNOTES Q ROUTE GAS SUPPLY LINE TO SECOND FLOOR. SEE 1/P2.02 FOR CONTINUATION. 0 ROUTE GAS SUPPLY LINE IN WALL FOR CONNECTIONS TO KITCHEN EQUIPMENT. REFER TO KITCHEN DRAWINGS FOR EXACT REQUIREMENTS AND CONNECTION SCHEDULE ON P0.01. PROVIDE GAS COCK, UNION AND FLEXIBLE CONNECTION. 10 11 12 13 14 15 PROVIDE GAS COCK, FIRE SAFETY SHUT —DOWN SOLENOID VALVE, WITH UNIONS, IN NON — CONCEALED ACCESSIBLE LOCATION, FOR GAS SERVICE TO GAS FIRED COOK LINE KITCHEN EQUIPMENT. INTERLOCK SOLENOID WITH HOOD FIRE SUPPRESSION SYSTEM. ROUTE 1/2" COLD WATER SUPPLY IN WALL FOR CONNECTION TO CARBONATOR. ALL PIPING DOWNSTREAM OF THE BACKFLOW PREVENTER IS TO BE NSF APPROVED PLASTIC PIPE. COPPER PIPE IS NOT ALLOWED. ROUTE HOT AND /OR COLD WATER SUPPLY DOWN IN WALL FOR ROUGH —IN AND CONNECTION TO KITCHEN EQUIPMENT. VERIFY EXACT SIZE AND ROUGH —IN REQUIREMENTS WITH KITCHEN EQUIPMENT SCHEDULE. INSTALL BACKFLOW PREVENTER ALONG WALL ON UNI —STRUT MOUNTING CHANNEL AT MAXIMUM 5' -0" ABOVE FINISHED FLOOR. ROUTE DRAIN TO NEAREST FLOOR SINK OR SERVICE SINK. ROUTE 1/2" COLD WATER SUPPLY DOWN TO WATER FILTER. ROUTE WATER FROM FILTER TO ICE MAKER ALONG WALL, PROVIDE SHUT —OFF VALVE. ROUTE HOT AND /OR COLD WATER PIPING DOWN IN WALL TO BELOW GRADE, ROUTE WATER SUPPLY UNDER COUNTER AND UP TO FIXTURE. ROUTE FILTERED COLD WATER TO KITCHEN EQUIPMENT. ROUTE WATER PIPING UP TO SECOND FLOOR SEE 1/P2.02 FOR CONTINUATION. ROUTE 3/4 INCH 180' F WATER SUPPLY DOWN TO DISHWASHER PROVIDE PRV. SEE 9/P3.0. ROUTE WATER SUPPLY FROM BACKFLOW PREVENTER. CONNECT NEW WATER PIPING TO EXISTING WATER PIPING IN CEILING. ROUTE WATER PIPING DOWN IN WALL. ROUTE HORIZONTALLY INSIDE WALL TO FIXTURES. aitttU� CODE COMPLIANCE AP VE1 FEB 2 0 2009 laDINGDIViSIOit p&o8z7 INTERFACE �� ENGINEERING Contact Victoria Haynes Project 2008 -0497 708 S.W. 3RD AVE., SUITE 400, POR'1'I.AND, OR 97204 PHONE 503.382.2266 FAX 503.382.2262 THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWLA, WASI -NGTON FIRST FLOOR PLAN PLUMBING WATER /GAS Job No: 0826 File Name: Date: Rev: 10/31/08 RECEIVED Nov nj 2008 PERMIT CENTEh Sheet No: P2.01 1....1........ <..........7 : :..• ............ . . FILE: 0497P2.02.DWG - P2.02 1 EDIT: 12/23/2008 3:26 PM BY VICTORIAN 1 PLOT: 12/23/2008 3:48 PM BY QUINLAN BELOG 0 2' 4' 8' SCALE: 1/4 " =1' -0" 1 SECOND FLOOR PLAN - PLUMBING SHEET KEYNOTES • ROUTE GAS SUPPLY LINE UP THROUGH ROOF FOR CONNECTIONS TO ROOFTOP AC UNIT. PROVIDE GAS COCK, PRESSURE REDUCING REGULATOR AND UNION. VERIFY EXACT EQUIPMENT REQUIREMENTS PRIOR TO ROUGH -IN. SEE 2/P3.01. • ROUTE 2" COLD WATER SUPPLY IN WALL FROM BELOW FLOOR AND MANIFOLD FOR CONNECTION TO FIXTURE BANK. PROVIDE SHUT -OFF VALVE AND SHOCK ARRESTOR WITH ACCESS. ✓ ROUTE HOT AND /OR COLD WATER PIPING IN WALL FROM BELOW FLOOR AND MANIFOLD FOR CONNECTION TO FIXTURES. PROVIDE SEISMIC BRACING IN ACCORDANCE WITH CODE AND AUTHORITY HAVING ,JURISDICTION. SEE 5/P3.01. INSTALL TRAP PRIMER IN WALL IN ACCESS PANEL AND ROUTE PIPING BELOW FLOOR TO FLOOR DRAINS IN RESTROOMS. • VENT PIPING FROM BELOW. a7 INSTALL GAS REGULATOR TO REDUCE FROM 2 PSI TO 6" W.C. AND ROUTE VENT TO OUTSIDE • HOT AND /OR COLD WATER PIPING DOWN TO FIRST FLOOR. SEE P2.01 FOR CONTINUA ?GOB Cat APPROVE' 3 20 7 `''' C , ILO NG DIVISION CITYOF DEC 2 6 2008 PERMIT CENTER INTERFACE E N G I N E E R I N G Contact Victoria Haynes Project 2008 -0497 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PHONE 503.382.2266 FAX 503.382.2262 MI a I e, 2525 Eaut 1: U3'0S9d0 SL Portland, OR 07214 503 )'8 3617 44001:. 503 26 1715 fax THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWILA, WASHINGTON I.1_P i78 SECOND FLOOR PLAN — PLUMBING Job No: 0826 File Name: Rev: Date: 12/17/08 n CITY REVIEW COMMENTS Sheet No: P2.02 N 1-1/4" G FILE: 0497P2.03.DWG — P2.03 I EDIT: 10/31/2008 1: 52 PM BY RACHELD I PLOT: 10/31/2008 3:35 PM BY RACHEL DEFOURI MAU -1 405 MBH 1-1/2" G 1 ROOF PLAN - PLUMBING 0 2' 4' 8' SCALE: 1/4"= V-0" 12 AC -3 180 MBH 3/4" G 1 3 • 0 A SHEET KEYNOTES �1 DAYLIGHT CONDENSATE DRAIN TO SPLASHBLOCK ON ROOF. ® ROUTE GAS PIPING FROM BELOW TO ROOF TOP HVAC UNIT. PROVIDE UNION, GAS COCK AND REGULATOR. ilt C DD O `n� Y COMPU`CC APPROVED fEB 20 21 c atyCirrawila INTERFACE ENGINEERING Contact Victoria Haynes Project 2008 -0497 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PHONE 503.382.2266 FAX 503.382.2262 THE OLD SPAGHETTI FACTORY SOUTHOENTER SQUARE TUKWLA, WASF- EvGTON ROOF PLAN — PLUMBING Job No: 0826 File Name: — Date: 10/31/08 Rev: RECEIVED NOV fl 6 2008 PERMIT CENTEF Sheet No: P2.03 SIZE TANK HGT ABOVE FLOOR NO. OF STRAPS LOCATION 66 GAL OR LESS 12" OR LESS 1 BETWEEN TOP 1/3 AND 1/2 OF TANK 66 GAL OR LESS MORE THAN 12" 2 TOP —IN TOP 1/3 OF TANK BOTTOM -3" ABOVE OR BELOW ACCESS PANEL 66 GAL TO 100 12" OR LESS 2 TOP —IN TOP 1/3 OF TANK BOTTOM -3" ABOVE OR BELOW ACCESS PANEL 66 GAL TO 100 MORE THAN 12" 3 TOP —IN TOP 1/3 OF TANK BOTTOM -3" BELOW ACCESS PANEL MIDDLE — CENTER OF TANK SECURE STRAP -' 1 DRAIN PAN SECTION DETAIL ROOFING fi NO SCALE ROUTE PIPING UP THRU ROOF WITH —IN THE PERIMETER OF THE MOUNTING CURB. MINIMUM 4" OVERLAP NO SCALE VERIFY VERTICAL CLEARANCE WITH SUPPLIED EQUIPMENT ANA FS DRAWINGS (6 AFF TYPICAL COORDINATE EXACT ROUTING W /STRUCTURAL AND WASTE PIPING CONDITIONS PRIOR TO ROUGH IN SEE SHEET P2.00 SEE FLOOR PLAN FOR CONTINUATION NO SCALE SEE ARCHITECHTURAL DRAWINGS FOR EXACT INFORMATION & DETAILS ON ROOFING SYSTEM PIPE ROOF PENETRATION NOTE: TYPICAL FOR BOTH ENDS OF SYSTEM 3 SLEEVE FOR SODA SYSTEM MINIMUM DISTANCE IS 10x PIPE DIAMETER. WASTE PIPING SECURE STRAP SLOPE PER WASTE PIPING SHEET METAL PAN ALL BENDS /TURNS TO BE WATER TIGHT CONNECTION LEAD FLASHING (3LB.) FLASHING TO ROOF SODA LINES BY OTHER f 4" PIPE NIPPLE SEDIMENT TRAP 4 GAS PIPE CONNECTION NO SCALE SOLDER LEAD COUNTER FLASHING COLLAR TO COUPLING CAP PROVIDE HOLES IN CAP FOR SODA LINES 4" AND /OR 6" PVC LONG SWEEP ELBOW PRESSURE REGULATOR. VENT TO ATMOSPHERE 1/4" PIPE PLUG (TYP. 2). UNION. TO EQUIP. FILE: 0497P3.01.DWG — P3.01 I EDIT: 10/31/2008 1:54 PM BY RACHELD I PLOT: 10/31/2008 3 :36 PM BY RACHEL DEFOURI 120'F HOT WATER RETURN. AQUASTAT CP -1 1 -1 2" 120'F HO WATER SUPPLY 1 -1/4" GAS COCK (TYP.) PRESSURE REGULATOR (TYP.) 1 -1/4" (TYP.) NOTE: MAINTAIN CLEARANCES TO COMBUSTIBLES AS REQUIRED BY MANUFACTURER. UTILIZE NON COMBUSTIBLE MATERIAL AS SPACER. T DRIP LEG (TYP.) SECURE CHANNEL TO WALL STRUCTURE AS REQUIRED. (TYPICAL) NO SCALE EARTHQUAKE BRACING (WATER HEATERS AND STORAGE TANKS) SHUTOFF VALVE (TYP.) DISCHARGE FULL SIZE TO FLOOR DRAIN (TYP.) 1 -1/2" FIXTURE NO SCALE WCO NO SCALE WCO FLOOR 140' THERMOMETER (TYP.) 1-1/2" WALL AT WATER HEATER AND STORAGE TANKS PROVIDE "SPACE MAKER" BRAND SEISMIC RESTRAINT SYSTEM (OR APPROVED EQUAL). SYSTEM TO MEET REQUIREMENTS FOR ZONE 4 SEISMIC INSTALLATIONS. tH -- ET -1, EXPANSION TANK. 6 WATER HEATING SYSTEM FLOOR MINIMUM MANUFACTURER CLEARANCE WALL BOOSTER HEATER WCO —SLOPE 2% FOOT VENT 7 ISLAND VENT DETAIL TYP. )! 185'R BY KITCHEN CONTRACTOR 185' CHECK STOP (TYP.) TRAP SEAL TO BE 2X TOTAL STATIC PRESSURE ROOF 2" DOMESTIC COLD WATER SUPPLY. CHECK VALVE (TYP.) 8 DISHWASHER CONNECTION DETAIL NO SCALE 3/4 THERMOMETER WITH WELL (40'- 240'F) CHECK VALVE PRESSURE REDUCING VALVE WITH INTERNAL BACK PRESSURE RELIEF —WATTS OR EQUAL 020 P.S.I. NOTE: 1. TRAP PIPING TO BE SAME SIZE AS AC UNIT DRAIN. 2. DRAIN PIPING TO BE COPPER OR ALTERNATE MATERIAL APPROVED BY LOCAL CODES. 180' HW FROM BOOSTER HEATER SEE P2.01 FOR CONT. 180' HWR TO BOOSTER HEATER RECIRC SYSTEM. STRAINER SHOCK ARRESTOR DISHWASHER 9 CONDENSATE TRAP NO SCALE 7 ROOFTOP AC UNIT ENTER OUTLET OVER SPLASH PLATE. " MAX ROVIDE FELT WALK PAD PLUG TYPICAL GENERAL NOTES A. CONTRACTOR TO VERIFY EXACT LOCATIONS, SIZES AND CONDITIONS OF EXISTING PLUMBING SYSTEM IN THE FIELD PRIOR TO INSTALLATION OF NEW PIPING RELATED TO WATER HEATING UPGRADE FOR THE FACILITIES. B. INSULATE ALL WATER PIPING ASSOCIATED WITH WATER HEATER FROM NEW CONNECTION TO EXISTING WATER SERVICE IN THE ROOM. C. SET NEW WATER HEATER TO PROVIDE 140 DEGREES HOT WATER FOR DISHWASHER BOOSTER HEATER. INSTALL MIXING VALVE TO REMAINING FIXTURES AND SET AT 120 DEGREES. D. INSTALL MIXING VALVES AT OR NEAR WATER HEATERS. E. SET AQUASTAT BELOW SET POINT OF MIXER. F. PROVIDE HEAT TRAP ON HOT INLET OF MIXER IF ABOVE WATER HEATER. SHEET KEYNOTES 01 ROUTE 185' HOT WATER RETURN PIPING FROM DISHWASHER TO CONNECT WITH BOOSTER HEATER RE—CIRCULATION KIT PROVIDED BY KITCHEN CONTRACTOR. CONNECT PER MANUFACTURER'S RECOMMENDATIONS. Q PRESSURE AND TEMPERATURE RELIEF VALVE DISCHARGE FULL SIZE TO FD -1. Q AIR INTAKE AND EXHAUST VENT SYSTEM BY HVAC CONTRACTOR. ROUTE CONDENSATE FROM VENT TO FLOOR DRAIN. TYPICAL V SEE DETAIL 5/P3.01 FOR RECOMMENDED EARTHEQUAKE BRACING OF EQUIPMENT. K SEE P2.02 FOR CONTINUATION. G-z7s INTERFACE ENGINEERING Contact Victoria Haynes Project 2008-0497 708 S.W. 31{1) AVE., SUITE 400, PORTLAND, OR 97204 PHONE 503.382.2266 FAX 503.382.22 THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWLA, WASI-INGTON DETAILS — PLUMBING Job No: 0826 File Name: Date: Rev: 10/31/08 RECEIVED Nov 0 6 7000 PERMIT CENTEE Sheet No: P3.01