HomeMy WebLinkAboutPermit PG08-278 - OLD SPAGHETTI FACTORYOLD SPA HETTI
FACTORY
17100 SOUTHCENTE'. PY
SUITS 160
GO 278
Parcel No.: 2623049081
Address:
Suite No:
Cityaf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PLUMBING /GAS PIPING PERMIT
17100 SOUTHCENTER PY TUHW
Permit Number:
Issue Date:
Permit Expires On:
PG08 -278
03/16/2009
09/12/2009
Tenant:
Name: OLD SPAGHETTI FACTORY
Address: 17100 SOUTHCENTER PY SUITE 160 , TUKWILA WA
Owner:
Name: WIG PROPERTIES LLC -SS
Address: 4811 134TH PL SE , BELLEVUE WA
Contact Person:
Name: BOB MARTIN
Address: 0715 SW BANCROFT ST , PORTLAND OR
Contractor:
Name: BUSH PLUMBING & MECHANICAL INC
Address: PO BOX 375 , EAST OLYMPIA WA
Contractor License No: BUSHPMI077JA
Phone:
Phone: 503- 225 -0433
Phone: 360 456 -8263
Expiration Date: 04/01/2010
DESCRIPTION OF WORK:
INSTALL COMPLETE WATER, SEWER AND GAS PIPE SYSTEMS. FOR RESTAURANT TENANT
IMPROVEMENT.
Value of Plumbing /Gas Piping:
Fees Collected:
$85,000.00
$1,119.25
Plumbing
Bathtub or combination bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic, with independent drain
Drinking fountain or water cooler (per head)
Food -waste grinder, commercial
Floor drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Uniform Plumbing Code Edition: 2006
International Fuel Gas Code Edition: 2006
FIXTURE TYPE AND QUANTITY
Plumbing (cont.)
0 Building sewer and each trailer park sewer 0
0 Rain water system - per dram (inside bldg) 0
0 Water heater and /or vent 2
0 Industrial waste treatment interceptor, including
0 its trap and vent, except for kitchen type
0 grease interceptors 0
0 Repair or alteration of water piping and/or water
15 treatment equipment 0
0 Repair or alteration of drainage or vent piping 0
7 Medical gas piping system serving (1 -5)
0 inlets /outlets for a specific gas 1
11 Medical gas piping (6 +) inlets /outlets 1
10 Gas Piping
2 Gas.piping outlets (0 -5) 5
6 Gas piping outlets (6 +) 10
* *continued on next page **
doc: UPC -10/06
PG08 -278 Printed: 03 -16 -2009
City ofTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: PGO8 -278
Issue Date: 03/16/2009
Permit Expires On: 09/12/2009
Permit Center Authorized Signature:
Alao,
3`k�` °1
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or th- erform. �- of work. I am authorized to sign and obtain this plumbing /gas piping permit.
Signature: .�. r Date:
Print Name:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: UPC -10/06
PG08 -278 Printed: 03 -16 -2009
Parcel No.: 2623049081
Address:
Suite No:
Tenant:
® •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
17100 SOUTHCENTER PY TUKW
OLD SPAGHETTI FACTORY
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
PG08 -278
ISSUED
11/06/2008
03/16/2009
1: ** *PLUMBING AND GAS PIPING * **
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R -3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
* *continued on next page **
doc: Cond -10/06
PG08 -278 Printed: 03 -16 -2009
0
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
P �
Print Name:
Date: ` I LP' 01
doc: Cond -10/06
PG08 -278 Printed: 03 -16 -2009
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
King Co Assessor's Tax No.: 21, 2-Y )LI-- RQ 9 1
_ Suite Number: % t
Site Address: � ��o SO VT -irFC� 7�.I �� ��p Q Floor: �
Tenant Name: OSF m E U O *JA-L -/ The PuSs/r 6 Na New Tenant: Dir Yes ❑ ..No
Property Owners Name: 606 Pf2OP PS Z-L-
Mailing Address: V// - /3 V 1-)/ACC Sir e6-7_2_ V0c WA
City State
Name: 46(98
Mailing Address:
E -Mail Address:
M/- i27)A)
071 .5) NC/ f
aczeit Q 7V7e GSc /na,tY 2
Day Telephone:
t�p'/1i2�9�1.t0
City
CO/ti Fax Number:
92006
Zip
(503) 22-5 -0433
QrQ_ 97Z3`'l
State Zip
07):57) 226 -6 0/ �
Company Name: _ A)P sd/2 F
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
Company Name: .&977 " 6&'()a/C -OS /f f re- c7v,eC L-Z-/9 p , /
Mailing Address: 2 5L S` 6. 1�3t/2/ .27/OE SA. / /�%L/9hUJ17 OR 97Z/ 7
�
' �� City State Zip
V
Contact Person: C' Ff M9iVi/tia t%O Day Telephone: 3)226 - 36 17
E -Mail Address: °L'F4 6 SPXL /gyp _ C'CM Fax Number: 3� 226 - 07/ S-
Company Name: (7 »!9t• '//l/ 7C/A/& JZRZ..
Mailing Address: /TD ,/,Gf /3t7/7 ,_5-1e-• S - 771 Contact Person: d...tet/C-iC MO/Pie/S. Day Telephone:
E-Mail Address: Fax Number:
City
sv re" 3oa
Q:\Applications\Forms- Applications On Line \3-2006 - Permit Application.doc
Revised: 9 -2006
bh
x6- r) A- f le ofd. S he fig-06R
G[�i4 P8Y4
State Zip
206 z S - 412
20 6 2-S5 - 06 /$
Page 1 of 6
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: — NOS Sc)RE --
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
+ s5 000 —7S(000 -I.
Valuation of Plumbing work (contractor's bid price): $
Valuation of Gas Piping work (contractor's bid price): $ 14
Scope of Work (please provide detailed information): ii/,S `� a� � £(414 j S'e�l'
iJ/ 2?. /!'l67�teak 9 S /45/J/ 47/1 4.1.€ CEA; 7goey . 1 k
l' i
• _ MLL _ /L v n I /
101 too (as
Building Use (per Int'I Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
..:i.r� -�,ji fi, , E
fixture Typ .� ,;r�,�,� ..
� Oty,.�
f ?r
F>>xtttrO Ype:v � , ...,.Oiy
tttr T �; a
F x C.. Yp�t3'"
..,
., YP
Offitiri l 'e
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
/.
Wash fountain
/
Gas piping outlets
/S.
Bidet
/
Food -waste grinder,
commercial
Receptor, indirect
waste
�/
Clothes washer, domestic
/'
Floor drain
/S–
Sinks
0L
i2.
Dental unit, cuspidor
—
Shower, single head trap
.......-+
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
'°]
Water Closet
6.
Building sewer or trailer
park sewer
Rain water system – per
drain (inside building)
Water heater and /or
vent
2,
Additional medical gas
inlets /outlets – six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
,/
Repair or alteration of water
piping and/or water treating
equipment
'
Repair or alteration
of drainage or vent
piping
,"
Medical gas piping system
serving one to five
inlets/outlets for specific gas
/
Q:WpplicationsTonns- Applications On Line - Permit Application.doc
Revised: 9 -2006
bh
Page 5 of 6
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDIN
Signature:
ORIZED
Date: r/
Print Name:
Mailing Address:
Day Telephone:
City
State
Zip
Date Application Accepted:
U'
(49
09
Date Application Expires:
�_ r
D p
Staff Initials:
(i4e.
Q:Wpplications\Forms- Applications On LineU -2006 - Permit Application.doc
Revised: 9 -2006
bh
Page 6 of 6
0
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 2623049081 Permit Number: PG08 -278
Address: 17100 SOUTHCENTER PY TUKW Status: PENDING
Suite No: Applied Date: 11/06/2008
Applicant: OLD SPAGHETTI FACTORY Issue Date:
Receipt No.: R09 -00048
Initials: WER
User ID: 1166
Payment Amount: $905.00
Payment Date: 01/09/2009 03:32 PM
Balance: $0.00
Payee: OSF INTERNATIONAL
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 1315 905.00
ACCOUNT ITEM LIST:
Description
GAS - NONRES
PLUMBING - NONRES
Account Code Current Pmts
000.322.103.00.0 165.00
000.322.103.00.0 740.00
Total: $905.00
doc: Receiot -06 Printed: 01 -09 -2009
0
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www. ci. tukwila. wa. us
RECEIPT
Parcel No.: 2623049081 Permit Number: PG08 -278
Address: 17100 SOUTHCENTER PY TUKW Status: PENDING
Suite No: Applied Date: 11/06/2008
Applicant: OLD SPAGHETTI FACTORY Issue Date:
Receipt No.: R08 -03704 Payment Amount: $214.25
Initials: WER Payment Date: 11/06/2008 02:50 PM
User ID: 1655 Balance: $905.00
Payee: OSF INTERNATIONAL
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 1314 214.25
ACCOUNT ITEM LIST:
Description
PLAN CHECK - NONRES
Account Code Current Pmts
000/345.830 214.25
Total: $214.25
doc: Receiot -06 Printed: 11 -06 -2008
/a
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PER IT NO.
CITY OF TUKWILA BUILDING DIVISION P-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: —Type of �spection:„. ,
0Z -A S , 77 1- / //1/4- /
Address: Date Called:
/7/06 se ,e?QkLLI9c�
Special Instructions: Date Wanted: a.m.
6 -2_ -Dc
Requester:
Phone No:
NIApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
f ) P d,'d)i5 lidvVe'(1-71/:94 S- Kiin 1 z / d/A- F
•sr, p /'ir°
AS AD iAl /(. - OF'n• o4d-/e
.-S
NIApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
f ) P d,'d)i5 lidvVe'(1-71/:94 S- Kiin 1 z / d/A- F
•sr, p /'ir°
AS AD iAl /(. - OF'n• o4d-/e
.-S
Inspector:
Date:
G- z5 -a5
INSPECTION FEE R = ' UIRED. Pr or to inspection, fee must be
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION RECORD
Retain a copy with permit 1
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 11-2-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: 5 >W
Type ofjpsgectiory:
/
Address:
:f
A a /
Date Called:
,/
Special Instructions:
j
Date Wanted:
G —22 - Q
`+p..
Requester:
Phone No:
-- , $� /
JApproved per applicable codes.
Corrections required prior to approval.
COMMENTS: .
/ea /,/Pi-
A a /
7196 /1
,/
3.) fl o T Cf/T Ste,
at/
-- , $� /
6 1 N-5i'
Date
0 REINSPECTION FA REQUI D. Prior to inspection, fee must be
at 6300 Southcenter Blvd., S te 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. 'PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Pegg:-Z7u
\cL-
Project:
out SPA 6r1 T
Type of Inspection:
F, N 4 r
4 /--
L) / p 'A' /1 - L esJ �� ,,
Address:
17/ o d Seh11hgok1 '' P'-1
Date Called:
.
17 . ,
Special Instructions:
Date Wanted:
Co— / "]
- c.-"9
.m.
p.m.
Requester:
Phone No:
Approved per applicable codes.
orrections required prior to approval.
COMMENTS: I ,A
_ ,L4 .' d% L ,ilif..,) %�?
4 /--
L) / p 'A' /1 - L esJ �� ,,
.
17 . ,
/ d��
- L .
- ,- ._A-.- k
2 (i'&, r r„..Af,> e
AJC. -& (4 t a?f1'1,
to!: t ( , e_t
IT '1 L (;
b (1 ��. /-ri I —
r k Jr
I fA 16.&p,41-1 h e-:t 3--,si)
„-, .
Inspecrr:
&Jo
Date: / , 1'7 _ 1
El$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
(206)431-3 70
i
PG 08s. -Z'r'
Pr01 U 3
•
Type of Inspection: Ai "t
4 -4-✓r
�%a,.,
Address: r, J (�
<
.S � �{,,� �
?Ai
Date ec
(ti A kb
. -h %;,
Special Instructions:
/
Date Wanted:
2
,.....,W,,
p.m.
Requester:
4c) A A 0/7
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
iJ
J I t'
iC6 A s 7-'k 57— A- 4 44^ 11
../1 /lip t JA
P_r 12,.1 u.
A,
1
LA it" t'
r a L ? I . -n
-%0
49.r : A
4c) A A 0/7
It
Inspecto r`
iJ
J I t'
Date: /
_ 3
- 0
❑$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD
Retain a copy with permit
INSPE ON NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project:
oLD s(.ram rL
Type f Inspection:
�f(e,(4- ii\—)
Address:
1`7100 ' •k I40fnl44'ti
Date Called:
Special Instructions:
Date Wanted:
— (a 0 Cj
a,
Requester:
Phone No
.- 03 -12d -2L2-7
()
Approved per applicable codes. D Corrections required prior to approval.
COMMENTS: P.
Inspect
Date:
$• REINSPEC ION FEE R 'UIRED. 'riorto inspection, fee ust be
6300 Southcenter Blvd. Suite 100. Call to schedule reinspection.
Recei T No.:
Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISIO
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
N �'
(206)431 -3670
Project: _
OLD c; ‘.)6,149E 0 4i
Type of Inspection: 1 PvC bi,—
1 _ 6vk-'j V
Address:
1-71 (3 0 j
�/
'e IA62 N'e v 0 -'
NA
Date Called:
Special Instructions:
Date Wanted:
1- 1 - ^2 -91 -0cl
p.m.
Requester:
_ <}yo (A4Af e-t�
Phone No:
3&C3 —570- 3Lo -2)
0 Approved per applicable codes. El Corrections required prior to approval.
COMMENTS: FA
10 AAA) m 14-479 2 Ls -.vJry - ST-4 i P _c,
-- A A p , < 7 en N t h -s -y , Rai c.
2�
(
_ lie-sA..) 5-1-4,
_ <}yo (A4Af e-t�
�3
Pqlo
14,l r V Fr,4vwrirt Cyr PAA,n - *IN,*
spe
f:
rum
`l ,� -�_
D e:
z�
❑6 .00 REINSPECTION' FEE REQUIRE DI. Prior to inspection, fee must be
d at 6300 Southcenter Blvd., Suite 1(00. Call to schedule reinspection.
Receipt No.:
Date:
._ - - .. .a..._��.. r . .. _. ..m.,d.......a.- ..1114,1•A,s.a...A. Ara.... -_ _.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Proje
,
Type of spectio :
// G✓� ktoV c.2 /VW Or Je‘/
Address:
fl/o 6 5.8
e•YZ/ ,D, ati
Date Called:
Special Instructions:
C
Date W nted:
--. 3 —o
Requester:
1
Phone No:
ElApproved per applicable codes. El Corrections required prior to approval.
COMMENTS: pejl-
L/ V
// G✓� ktoV c.2 /VW Or Je‘/
::; )15 ?.d7■
, ./Z-7 Gam/&
— 4/9,44,-.../ .
/--. \
Date:
y -5 -o7
60.00 REINSPECTION EE REG[UIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
T
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
. CITY OF TUKWILA BUILDING DIVISION 11.'
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3f7
Protect: � �
LO► S" 0 /T / . a�,
]type of Inspection:
. vL?. A
��
Address: / r,
/00
Date Cal ed:
— —3 -v7
Special Instructions:
Date Wanted:
a.m.
Requester:
Phone No:
pproved per applicable codes. El Corrections required prior to approval.
COMMENTS:
•Dk-
r
Date:
1=1$58.00 REINSp CTION FEE REQUIRED. Prior o inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD•'
Retain a copy with permit
INSPECTION NO PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION •
''
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3
;5.2'.eg-i! 78
Project: C
Type of Inspection:
Address:
4te Called:
Special Instructions:
Date a ted:
�--- U
�._.:t'
p.m.
Requester:
Phone
�4.. - 71-4 " `.." ---
Approved per applicable codes. [J Corrections required prior to approval. g
COMMENTS: pix
0,444 ti /74a..i ThJV
Inspector:
Date' t°
❑$60.00 REINSPECTIOI FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
Aoki.
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #1 00,1 kwila, WA 98188 (206)431 -36
INSPECTION RECORD
Retain a copy with permit
1766,1-2 7c9
PERMIT NO.
Project:
C 10 SPE6N - SAe-r.
Type of Inspection: �,
Qdzit,10 WoR.LL
Address:
j1)05 SoC•,)+. Pyv
Date Called:
Special Instructions:
.
Date Wanted:
3 - L 7- uci
a.m.
cp•m1
Requester:
Phone No:
3 Go— 8 7o- 3ze.r3
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
l� — 6'vo4S NI -rte
A.tro4-24iT,J
M4
0 REINSPECTION FEE REQUIRED. rior to inspection, fee must be
d at 6300 Southcenter Blvd., Suite 10p Call to schedule reinspection.
Receipt No.:
Date:
• Page l of l
Greg Villanueva - Old Spaghetti Factory - PG08 -278
From: Greg Villanueva
To: bobm @thedussingroup.com
Subject: Old Spaghetti Factory - PG08 -278
CC: Mike Cusick
Hello Bob,
Regarding the grease interceptor, I understand your concerns with the amount of grease that can be accounted
for from the dishwasher however, Tukwila does not want the dishwasher routed to the interceptor. All other
gray water needs to be routed to the interceptor.
If you still have concerns, please contact Mike Cusick P.E. (Water /Sewer Engineer), at (206) 431 -2441 or email
at mcusick @ci.tukwila.wa.us
Also, our office will be closed 1/19, Monday.
Thank you for your request for clarification.
Greg Villanueva
Development Engineer
Public Works Department
206 - 431 -2442 office
206 - 571 -6321 cell
206 - 431 -3665 fax
qvillanueva@ci.tukwila.wa.us
•
Cizy of f Tukwila
Jim Haggerton, Mayor
January 13, 2009
Department of Community Development Jack Pace, Director
Bob Martin
0715 SW Bancroft St
Portland OR 97239
RE: CORRECTION LETTER #1
Plumbing/Gas Piping Application Number PG08 -278
Old Spaghetti Factory —17100 Southcenter Py Suite 160
Dear Mr. Martin,
This letter is to inform you of corrections that must be addressed before your plumbing permit can be
approved. All correction requests from each department must be addressed at the same time and
reflected on your drawings. I have enclosed comments from the Public Works Departments. The
Building Department has no comments at this time.
Public Works Department; Greg Villanueva at 206 - 431 -2442 if you have questions regarding
the attached comments.
Please address the attached comments in an itemized format with applicable revised plans,
specifications, and /or other documentation. The City requires that two (2) complete sets of revised
plans, specifications and/or other documentation be resubmitted with the appropriate revision
block.
In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person
and will not be accepted through the mail or by a messenger service.
If you have any questions, please contact me at (206) 431 -3670.
Sincerely,
Bill Rambo
Permit Technician
encl
xc: File No. PG08 -278
P:\Permit Center\Correction Letters\2008\P008 -278 Correction Ltr #2.DOC
wer
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
•
CITY OF TUKWILA
PUBLIC WORKS DEPARTMENT
REVIEW COMMENTS
DATE: January 13, 2009
PROJECT: Old Spaghetti Factory
17100 Southcenter Parkway, Suite 160
REVIEW NUMBER 2
PERMIT NO: PG08 -278
PLAN REVIEWER: Contact Greg Villanueva at (206) 431 -2442, if you have any
questions regarding the following comments.
Remove dishwasher connection to grease line and show connection to sanitary
sewer (waste line). Route all gray water from sinks, floor drains, drains under
garbage compactors to grease interceptor line.
TRANSMITTAL
Date: December 17, 2008
To: Allen Johannessen / Plans Examiner
City of Tukwila Building Division
- and -
Greg Villanueva / Plans Examiner
City of Tukwila Public Works Department
Job: 0826 The Old Spaghetti Factory Restaurant
17100 Southcenter Parkway, Suite 160
Tukwila, WA 98188
Permit #: PG08 -278
Ifni Ali. I
arc itec ure
2525 E Burnside Street
Portland, Oregon 97214
503.226.3617 phone
503.226.3715 fax
architects @seallp.com
Mr. Johannessen, attached I am sending you the following clarifications and
response to the Plumbing Review letter dated December 10th, 2008.
Review Comment 1.
Response:
"Indicate on the plans specifically where all Backflow
Prevention devices shall be installed. Provide the
manufacturers specification and installation manual for
each device. Identify those fixtures requiring back flow
devices or indicate fixtures provided with their own back
flow device."
Backflow prevention for the tenant space supply is
provided by the building shell and not part of the tenant
improvement. See existing shell drawings for location of
backflow preventer.
Reverse pressure backflow preventer (BP -1 is being
installed in the tenant space for the beverage
carbonator. See floor plans (P2.01 and revised sheet
P2.02) and plumbing fixture schedule (P0.11) for details.
Installation manuals to be supplied by contractor per
specifications.
Review Comment 2. "Show back flow or vacuum breaker devices for mop
sinks or similar and provide manufacturers
specifications."
Response: A vacuum breaker for the mop sink is included on the
plumbing fixture schedule and is integral to the faucet.
See revised drawing P0.11 (Delta 1, 12/17/08)
Review Comment 3. "Identify where the fire- sprinkler riser connections shall
be located. Provide the backflow device manufacturers
specifications and installation instructions."
Response: The fire sprinkler riser and backflow prevention was
installed as part of the building shell. The existing service
is being modified to match the tenant space floor plans
as well as Code requirements. See shell drawings for
exact location of fire sprinkler riser and backflow
preventer.
LLP
Mr. Villanueva, attached I am sending you the following clarifications and
response to the Public Works review letter dated December 9th, 2008.
Review Comment 1. "Add abbreviation GI (dedicated grease line) to Plumbing
Symbol List."
Response: Added to revised sheet P0.01 (Delta 1, 12/17/08)
Review Comment 2.
"Remove dishwasher connection to grease line and
show connection to sanitary sewer (waste line). Route all
gray water from sinks, floor drains, drains under garbage
compactors to grease interceptor line."
Response: Waste lines revised on sheet P2.00 (Delta 1, 12/17/08)
Thanks for your help and let me know if you need anything else.
Sincerely,
Jeff Hammond
Project Manager
Scott 1 Edwards Architecture
0
Chj' of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
December 10, 2008
Bob Martin
0715 SW Bancroft St
Portland OR 97239
RE: CORRECTION LETTER #1
Plumbing/Gas Piping Application Number PG08 -278
Old Spaghetti Factory —17100 Southcenter Py Suite 160
Dear Mr. Martin,
This letter is to inform you of corrections that must be addressed before your plumbing permit can be
approved. All correction requests from each department must be addressed at the same time and
reflected on your drawings. I have enclosed comments from the Building and Public Works
Departments.
Building Department: Allen Johannessen at 206 - 433 -7163 if you have questions regarding
the attached comments.
Public Works Department; Greg Villanueva at 206 - 431 -2442 if you have questions regarding
the attached comments.
Please address the attached comments in an itemized format with applicable revised plans,
specifications, and/or other documentation. The City requires that two (2) complete sets of revised
plans, specifications and/or other documentation be resubmitted with the appropriate revision
block.
In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person
and will not be accepted through the mail or by a messenger service.
If you have any questions, please contact me at (206) 431 -3670.
Sincerely, (�
Bill Rambo
Permit Technician
encl
xc: File No. PG08 -274
P:\Permit Center\Correction Letters \2008\PG08 -278 Correction Ltr /11.DOC
wer
AM!) Cnrrthrvntvr Rnnlvriard Snit," !Etna • Tukwila Waehinotnn OR1RR e Phnno• 7fA- A21_2A711 a ray. 9/)A_421_2AAG"
I I
Tukwila Building Division
Allen Johannessen, Plan Examiner
Building Division Review Memo
Date: November 19, 2008
Project Name: Old Spaghetti Factory
Permit #: PG08 -278
Plan Review: Allen Johannessen, Plans Examiner
The Building Division conducted a plan review on the subject permit application. Please address the
following comments in an itemized format with revised plans, specifications and/or other applicable
documentation.
(GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size).
(If applicable) Structural Drawings and structural calculations sheets shall be original signed wet
stamped, not copied.)
1. Indicate on the plans specifically where all Backflow Prevention devices shall be installed. Provide
the manufactures specification and installation manual for each device. Identify those fixtures
requiring back flow devices or indicate fixtures provided with their own back flow device. (2006
UPC Section 603)
2. Show back flow or vacuum breaker devices for mop sinks or similar and provide manufactures
specifications. (UPC 603.4.17)
3. Identify where the fire- sprinkler riser connections shall be located. Provide the backflow device
manufactures specifications and installation instructions. (UPC 603.4.16)
Should there be questions concerning the above requirements, contact the Building Division at 206 -431-
3670. No further comments at this time.
f
® •
CITY OF TUKWILA
PUBLIC WORKS DEPARTMENT
REVIEW COMMENTS
DATE: December 9, 2008
PROJECT: Old Spaghetti Factory
17100 Southcenter Parkway, Suite 160
PERMIT NO: PG08 -278
PLAN REVIEWER: Contact Greg Villanueva at (206) 431 -2442, if you have any
questions regarding the following comments.
1. Add abbreviation GI (dedicated grease line) to Plumbing Symbol List.
2. Remove dishwasher connection to grease line and show connection to
sanitary sewer (waste line). Route all gray water from sinks, floor drains,
drains under garbage compactors to grease interceptor line.
• koRfNlT COORD COPY •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG08 -278 DATE: 01 -28 -09
PROJECT NAME: OLD SPAGHETTI FACTORY
SITE ADDRESS: 17100 SOUTHCENTER PY
Original Plan Submittal
X Response to Correction Letter # 2
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
Building Division n
['Mir *s Structural
Fire Prevention
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Xi
Comments:
Incomplete
DUE DATE: 01-29-09
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES /THURS ROUTING:
Please Route g Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
REVIEWER'S INITIALS:
Approved with Conditions
DUE DATE: 02-26-09
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
OPERMlT COON COPY •
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: PG08 -278 DATE: 12 -26 -08
PROJECT NAME: OLD SPAGHETTI FACTORY
SITE ADDRESS: 17100 SOUTHCENTER PY, STE 160
Original Plan Submittal
X Response to Correction Letter # 1
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
CI kwBuil. � g Division
Publii Works f ��i Xi / 115,01
DETERMINATI N OF COMPLETENESS: (Tues., Thurs.)
Fire Prevention
Structural
n
Planning Division
nPermit Coordinator
n
Complete
Comments:
Incomplete n
DUE DATE: 12-30 -08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS R TING:
Please Route Structural Review Required ri No further Review Required ri
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 01-27-09
Approved n Approved with Conditions Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
1— 13-0?
Bldg ❑ Fire ❑
Ping ❑ PW Staff Initials:
Documents/routing slip.doc
2 -28 -02
PE `y MIT COORD COPY •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: PG08 -278
DATE: 11 -06 -08
PROJECT NAME: OLD SPAGHETTI FACTORY
SITE ADDRESS: 17100 SOUTHCENTER PY SUITE 160
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS: I
B i�ng
P bl'c Wor
1� al-nks n 4 Fet,06
Fire Prevention
n
Planning Division
Structural n Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
n
DUE DATE: 11 -11 -08
Not Applicable
Permit Center Use Only _ •
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
Structural Review Required
REVIEWER'S INITIALS:
❑ No further Review Required
DATE:
n
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
DUE DATE: 12 -09-08
Not Approved (attach comments)
REVIEWER'S INITIALS:
DATE:
• Permit Center Use Only ' • "G
CORRECTION LETTER MAILED: l� LU'O6
Departments issued corrections: Bldg Fire ❑
Ping ❑
PW Staff Initials:
we
Documents/routing slip.doc
2 -28-02
City of Tukwila
Steven M Mullet, Mayor
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tulcwila.wa.us
Steve Lancaster, Director
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: /
❑ Response to Incomplete Letter #
Plan Check/Permit Number:
Response to Correction Letter # 2
DDB -27,g
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name:
Project Address:
Contact Person:
7?t dL faApJ 7
or
Summary of Revision:
i�/fiZp7N
RECEVED
ow O
IJAN 2 8 2009
PERmo/ CtNTEk
Phone Number:
• •1 lSh c-c'a ' =e- •, e a _i i dJI
iLA•1 �/ _ 4 / / -r , •! , i1 /
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by: / f�-
XEntered in Permits Plus on
\applications\forms- applications on Iine\revision submittal
Created: 8 -13 -2004
Revised:
..,'.
City
111
f Tukwila
•
Steven M. Mullet, Mayor
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
Steve Lancaster, Director
1
REVISION SUBMITTAL
1
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: 12-23 -08
Plan Check/Permit Number: PG08 -278
❑ Response to Incomplete Letter #
® Response to Correction Letter # 1 cOF
K►NILq
❑ Revision # after Permit is Issued DEC 2 61008
❑ Revision requested by a City Building Inspector or Plans Examiner r+ERM►T CEv'EA
Project Name: OLD SPAGHETTI FACTORY
Project Address: 17100 Southcenter Py — Suite 160
Contact Person: JJ,FF 1-IAr 1Mor1O Phone Number: 5O - 22.4 -
Summary of Revision: S 5g A TT AC C li ITO 11 -- r-t 1 Z re a 12ESPor4Sr LL <
Sheet Number(s): PO -01 , P0. 11 I P2. oo j ► 2.0 2.
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
Entered in Permits Plus on
\applications \forms - applications on line\revision submittal
Created: 8 -13 -2004
Revised:
3
Untitled Page
0
•
General /Specialty Contractor
A business registered as a construction contractor with LEtI to perform construction work
within the scope of its specialty. A General or Specialty construction Contractor must
maintain a surety bond or assignment of account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
BUSH PLUMBING It
MECHANICAL INC
3604568263
P 0 BOX 375
EAST OLYMPIA
WA
98540
County THURSTON
Business Type Corporation
Parent
Company
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Previous
License
Next License
Associated
License
Specialty 1
Specialty 2
601446057
ACTIVE
BUSHPMI077JA
CONSTRUCTION
CONTRACTOR
4/1/1993
4/1/2010
BUSHPM *118JF
PLUMBING
UNUSED
Business Owner Information
Name
Role
Effective Date
Expiration Date
BUSH, JAMES R
PRESIDENT
04/01/1993
Bond
Amount
BUSH, LINDSAY A
SECRETARY
03/05/2002
634942
BUSH, KRIS A
VICE PRESIDENT
04/01/1993
Date
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
2
CBIC
634942
04/01/2002
Until
Cancelled
Date
Date
$6,000.00
01/31/2002
1
CBIC
634942
04/01/1993
04/01/2002
$4,000.00
Insurance Information
Page 1 of 2
https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License =BU SHPMI077JA
03/16/2009
Company
Policy
Effective
Expiration
Cancel
Impaired
Received
Insurance
Name
Number
Date
Date
Date
Date
Amount
Date
AMERICAN
8
FIRE AND
BKA53201417
06/13/200806/13
/2009
$1,000,000.0004
/30/2008
CASUALTY
https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License =BU SHPMI077JA
03/16/2009
WATER SERVICE
CALCULATIONS
PUBLIC
GENERAL
USE
DESORPTION
PLEUC
QB+ERAL
USE
TOTAL
UNTB
(.75)
HOT
WATER
2
BAR SINK - -2" MIN. DRAIN BEYOND TRAP ARM
2
BAR SINK
2.00
4.00
3.00
5
HAND SINKS
2.00
10.00
7.50
1
DISHWASHER
0.00
0.00
4.00
2
ICE MAKERS
1.50
3.00
0.00
3
TEA MAKERS
1.50
4.50
0.00
3
COFFEE MAKERS
1.50
4.50
0.00
1
STEAMER
1.00
1.00
0.00
2
KETTLE
2.00
4.00
3.00
2
RANGE FAUCET
2.00
4.00
3.00
5
CARBONATOR
1.50
7.50
0.00
2
WATER FILLERS
1.50
3.00
0.00
1
DISH TABLE
1.50
1.50
0.00
2
BEVERAGE CENTER
1.50
3.00
0.00
2
4- COMPARTMENT SINK
4.00
8.00
6.00
2
PRE -RINSE SINK
4.00
8.00
6.00
3
KITCHEN SINK, DOMESTIC
1.50
4.50
3.38
8
LAVATORY
1.00
8.00
6.00
1
SERVICE SINK OR MOP BASIN
3.00
3.00
2.25
7
WATER CLOSET, 1.6 GPF, FLUSHVALVE
5.00
35.00
0.00
2
URINAL, 1.0 GPF, FLUSHVALVE
4.00
8.00
0.00
TOTAL FIXTURE UNITS
116.50
44.13
FLOW IN GPM
72
26
IRRIGATION FLOW IN GPM
0
TOTAL GPM REQUIRED
72
a.
MINIMUM DAILY SERVICE PRESSURE
75
Psi
b.
STATIC HEAD LOSS .434 /Fr X 25
10.85
psi
c.
WATER METER PRESSURE DROP 2"
4.5
Psi
d.
BACKFLOW PREVENTER 2"
5
Psi
e.
PRESSURE REQUIRED AT FIXTURE
35
Psi
PRESSURE AVAILABLE FOR
FRICTION LOSS, a - b - c - d - e
19.65
psi
TOTAL EQUIVALENT PIPE LENGTH
189
LENGTH X 1.25
236.25
ft
MAXIMUM FRICTION LOSS
PRESS. AVAIL. X 100' /EQUIV. LENGTH
8.317
psi
SERVICE SIZE FROM SUB -METER
2"
SANITARY DRAINAGE
CALCULATIONS
PUBLIC
fiB+►L
USE
DEt3C PT ON
PUBLIC
GENERAL
USE
TOTAL
UNTIE
2
BAR SINK - -2" MIN. DRAIN BEYOND TRAP ARM
2.00
4.00
1
DISHWASHER, DOMESTIC, INDEPENDENT DRAIN
4.00
4.00
2
LAVATORY, SINGLE
1.00
2.00
2
LAVATORY, SETS OF 2 OR 3
2.00
4.00
11
RECEPTOR, INC. WASTE, 3" TRAP
1.00
11.00
1
SERVICE SINK OR MOP BASIN, 3" TRAP
3.00
3.00
2
4- COMPARTMENT SINK
3.00
6.00
1
SINK, GENERAL, 2" TRAP
3.00
3.00
2
URINAL
2.00
4.00
7
WATER CLOSET, 1.6 GPF, FLUSHOMETER VALVE
4.00
28.00
5
PREP SINKS
3.00
15.00
5
HAND SINKS
2.00
10.00
TOTAL FIXTURE UNITS
94.00
FILE: 0497P0.01.DWG - P0.01 I EDIT: 12/23/2008 3 :26 PM BY VICTORIAH I PLOT: 12/23/2008 3 :46 PM BY QUINLAN BELOG
GAS CALCULATIONS
FIXTUFE DESCRPTION
KIT4 F 1 EOUI NENT
CONVECTION OVEN
BRAISING PAN
FLOOR KETTLE
RANGE (COUNTER TOP)
GRIDDLE
CHEESE MELTER
CONVECTION OVEN
PASTA COOKER
MECHANCAL EOUPWENT
AC -1 ROOF TOP UNIT
AC -2 ROOF TOP UNIT
AC -3 ROOF TOP UNIT
AC -4 ROOF TOP UNIT
AC -5 ROOF TOP UNIT
AC -6 ROOF TOP UNIT
MAU -1 MAKE UP AIR UNIT
PLUMBING EAUPNENT
WH -1 DOMESTIC WATER HEATER
WH -2 DOMESTIC WATER HEATER
204 WATER BOOSTER HEATER
NO. OF
BTU/Hi TOTAL
F9)(T. I+PUT gruff l
1 40,000
1 144,000
1 15,000
1 80,000
1 40,000
1 40,000
1 115,000
2 150,000
40,000
144,000
15,000
80,000
40,000
40,000
115,000
300,000
1
1
1
1
1
1
233,000
198,000
189,000
99,000
45,000
45,000
176,000
/1\
233,000
198,000
189,000
99,000
45,000
45,000
176,000
1 199,000 199,000
1 199,000 199,000
1 199,000 199,000
SIZING BASED ON 2007 MECHANICAL SPECIALTY CODE
2 PSI SUPPLY PRESSURE WITH 1 PSI PRESSURE DROP
147 FEET DEVELOPED LENGTH
3
2 -1 /2"
2"
1 1/2"
1 1/4"
1"
3/4"
1/2"
22,900 CFH
13,000 CFH
8,130 CFH
4,220 CFH
2,820 CFH
1,370 CFH
751 CFH
372 CFH
R'.
WCO
Co
QD
VTR
;o+
180' 180'R
2#G
G
D
PLUMBING SYMBOL LIST
VALVES
VALVE, GENERAL
CHECK VALVE
QUARTER TURN VALVE
GLOBE VALVE
PRESSURE REDUCING VALVE
BALANCING VALVE
FITTINGS
PIPE RISE
PIPE DROP
TEE UP ON PIPE
TEE DOWN ON PIPE
CONTINUATION
CAP
HOSE BIBB
WALL CLEANOUT
FLOOR CLEANOUT
FLOOR DRAIN
FLOOR SINK
VENT THROUGH ROOF
PIPING SYSTEMS
COLD WATER PIPING
140' HOT WATER PIPING
140'R HOT WATER PIPING
180' HOT WATER PIPING
180'R HOT WATER PIPING
2# PSI GAS PIPING
GAS PIPING, 6 IN. W.C.
CONDENSATE PIPING
BEVERAGE LINE
FCW FILTERED COLD WATER
SANITARY PIPING BELOW
GRADE OR FINISHED FLOOR
WASTE PIPING ABOVE
GRADE WITH DRAIN PAN
SANITARY PIPING ABOVE
GRADE OR FINISHED FLOOR
GI
GREASE WASTE TO OUTSIDE
INTERCEPTOR
SANITARY VENT PIPING
PIPING BELOW FLOOR
ABBREVIATIONS
AFF ABOVE FINISHED FLOOR
BFP BACKFLOW PREVENTER
BFF BELOW FINISHED FLOOR
CD CONDENSATE DRAIN
CONT. CONTINUATION
CV CHECK VALVE
CW COLD WATER
DIA DIAMETER
FT FEET
GAL GALLONS
GPF GALLONS PER FLUSH
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HD HEAD
HP HORSE POWER
HW HOT WATER
HWR HOT WATER RETURN
ID INSIDE DIAMETER
IE INVERT ELEVATION
IN INCHES
LBS. POUNDS
MIN MINIMUM
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
PD PRESSURE DROP
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
QTY QUANTITY
SF SQUARE FEET
SOV SHUT OFF VALVE
SP STATIC PRESSURE
TP TOTAL PRESSURE
V VENT
W.C. WATER COLUMN
W/ WITH
W/O WITHOUT
A. CONDITIONS SHOWN ON THE PLANS RELATIVE TO THE
WORK TO BE PERFORMED ARE BASED ON THE BEST
INFORMATION AVAILABLE BUT ARE SUBJECT TO
VERIFICATION. VERIFY LOCATIONS AND ELEVATIONS OF
UTILITIES TO BE CROSSED OR CONNECTED. CORRECT
DEFICIENCIES CAUSED BY FAILURE TO PERFORM SUCH
VERIFICATIONS AT NO EXPENSE TO OWNER.
IMMEDIATELY NOTIFY ARCHITECT AND ENGINEER OF
CONDITION IN CONFLICT WITH THE PLANS.
B.
C.
PROVIDE PIPING, EQUIPMENT, AND MATERIALS IN
ACCORDANCE WITH APPLICABLE PLUMBING CODE
REGULATIONS AND STANDARDS. AUTHORITIES HAVING
JURISDICTION, AND AS OTHERWISE RECOMMENDED OR
DIRECTED BY MANUFACTURERS.
PROVIDE GAS SHUTOFF VALVES, PRESSURE
REGULATORS AND UNIONS (OR CODE APPROVED
APPLIANCE CONNECTORS) AT CONNECTIONS TO ALL
GAS -FIRED EQUIPMENT. PROVIDE REGULATOR RELIEF
VENT PIPING TO ATMOSPHERE WHERE REQUIRED BY
CODE.
D. COORDINATE INSTALLATION OF PIPING BELOW AND
ABOVE GRADE WITH STRUCTURAL COMPONENTS AND
OTHER SYSTEM INSTALLATIONS.
E. PROVIDE CLEANOUTS FOR SANITARY WASTE SYSTEMS
WHERE SHOWN AND AS OTHERWISE REQUIRED BY CODE.
F. DO NOT SCALE THESE DRAWINGS. OBTAIN SPECIFIC
INFORMATION CONCERNING DIMENSIONS, LOCATIONS AND
REQUIREMENTS OF FIXTURES, DRAINS, EQUIPMENT, ETC.
FROM KITCHEN CONSULTANT FURNISHED FIXTURE
CUTSHEETS /FIXTURE LAYOUT PLANS AND
ARCHITECTURAL DRAWINGS.
G. LOCATE ALL VALVES FOR SERVICE ACCESSIBILITY.
VALVES INSTALLED ABOVE CEILINGS SHALL BE WITHIN
18" OF CEILING.
H. NO WATER, SEWER, GAS OR VENT PIPING SHALL BE
INSTALLED WITHIN ANY INSULATED COOLER OR FREEZER
WALL.
I. INSTALL ALL OVERHEAD PIPING AS CLOSE TO
STRUCTURE AS POSSIBLE IN AREAS WITH EXPOSED
ROOF STRUCTURE.
BVISIUNS
� e to the scope
No changes shall be prior made
approval at
of work without p IDty` +soon.
Tukwila Building tan submittal
Revisions will require a new P
NOTE:
d may include additional plan review tees.
and
NOTES
J. FURNISH AND INSTALL ALL VALVES, TRAPS, STRAINERS,
BACK FLOW PREVENTERS, ETC. NOT FURNISHED BY
EQUIPMENT SUPPLIER, BUT NEEDED FOR PROPER
EQUIPMENT OPERATION.
K. ALL FLOOR SINKS AND OTHER INDIRECT WASTE
RECEPTORS SHALL BE LOCATED WHERE THEY ARE
READILY ACCESSIBLE FOR INSPECTION AND CLEANING.
L. REFER TO KITCHEN CONSULTANT DRAWINGS (K) FOR
EXACT LOCATION OF ALL FIXTURES DRAINS AND
EQUIPMENT AND EXACT DESCRIPTION AND ROUGH -IN
REQUIREMENTS OF ALL KITCHEN EQUIPMENT BEING
CONNECTED TO.
M. SHUTOFF VALVES TO BE INSTALLED IN ALL WATER AND
GAS PIPING AT LOCATIONS SHOWN, AND WHERE NEEDED
TO PROVIDE ADEQUATE ZONING FOR SERVICING PIPING
AND EQUIPMENT. PROVIDE ACCESS PANELS IF CEILING
AND STRUCTURAL CONDITIONS DO NOT ALLOW NORMAL
ACCESS. COORDINATE EXACT TYPE AND LOCATION WITH
OWNER AND GENERAL CONTRACTOR PRIOR TO
ROUGH -IN.
N. LOCATE ALL VTR A MINIMUM OF 1O' -0" FROM OUTSIDE
AIR OPENINGS OF ROOFTOP HVAC EQUIPMENT.
0. ALL FLOOR DRAINS AND FLOOR SINKS SHALL HAVE
TRAP PRIMER CONNECTIONS IN ACCORDANCE WITH THE
STANDARDS OF LOCAL AUTHORITIES.
P3.01
FIL--E COPY eia
Permit No.r .et
1
Plan review approval is subject to error and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Fie Cop a conditions is acknowledged:
BY-
Date:
SEPARATE PERMIT
REQUIRED FOR:
L!? Mechanical
(Electrical
0 Plumbing
0 Gas Piping
City of Tukwila
BUILDING DIVISION,
qty O tlbkwIIel
BUILDING DIVISION
DRAWING INDEX
P0.01 LEGEND, SYMBOLS, DRAWING INDEX - PLUMBING
P0.11 SCHEDULES - PLUMBING
P2.00 FIRST FLOOR PLAN - PLUMBING - WASTE /VENT
P2.01 FIRST FLOOR PLAN - PLUMBING - WATER /GAS
P2.02 SECOND FLOOR PLAN - PLUMBING
P2.03 ROOF PLAN - PLUMBING
DETAILS - PLUMBING
CORRECTION
LT R#
6 ru b
CODE COMPLIANCE
APPROVED
FEB 2 0 009
Of Tukwila
WARDING DIVISION
R CEIV D
CITY OF TU
DEC 2 6 2008
PERMIT CENTER
?koS
INTERFACE
E N G I N E E R I N G
Contact
Victoria Haynes
Project
2008 -0497
708 S.W. 3RD AVE., SUM 400, PORTLAND, OR 97204
PHONE 503.382.2266 TAX 503.382.2262
PLUMBING
Job No:
File Name:
Date:
Rev:
arc nI;.Ire
2525 Ent - nunde t4.
Portland, OR 97214
503.2a;,3617 phone
503 'M.3715 fax
ue. aiip,c0ni
THE OLD
SPAGHETTI
FACTORY
SOUTHCENTER SQUARE
TUKWILA, WASHINGTON
LEFT
LEGEND, SYMBOLS, DRAWING INDEX
0826
12/17/08
CITY REVIEW COMMENTS
Sheet No:
P0.01
KITCHEN FIXTURE CONNECTION SCHEDULE
SYMBOL
FIXTURE
CONNECTION
W
CONNECTION SIZE
CW
REMARKS
GAS
OW
HW
W
IND. W
V
a
ICE MAKER /BIN
- --
1/2"
- --
- --
I.W.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
a
ICE MAKER /BIN
- --
1/2"
- --
- --
LW.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
HB -1
SOILED DISH TABLE
- --
- --
- --
- --
LW,
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
a
PRE -RINSE ASSEMBLY
- --
1/2"
1/2"
- --
- --
- --
1/2"
8
DISHWASHER
- --
- --
3/4"
___
I.W.
___
ROUTE DRAIN TO INDIRECT WASTE RECEIVER.
CONNECT TO REMOTE BOOSTER HEATER.
a
4- COMPARTMENT SINK
- --
- --
- --
1 -1 /2'
- --
- --
WITH PRE -RINSE SINK AND SCRAP BUCKET
16
BIG FLOW FAUCETS (2 SETS)
- --
3/4"
3/4"
- --
- --
- --
-- --
a
PRE -RINSE ASSEMBLY
- --
1/2"
1/2"
- --
- --
- --
20
FLOOR TROUGH
- --
- --
- --
4"
- --
- --
2"
a
MOP SINK
_ -_
_ --
_ --
1 -1/2"
-_-
- --
PROVIDE MS -1 / \
0
SERVICE FAUCET
___
1/2"
1/2"
___
___
___
- --
a
HAND SINK FAUCETS (4 SETS)
- --
1/2"
1/2"
- --
- --
- --
INSTALL WITH MV -2
28
HAND SINK (4)
- --
- --
- --
1 -1/2"
- --
- --
a
PREP SINK TABLE
----°
- --
- --
- --
I.W.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
34
PREP SINK FAUCETS
- --
1/2"
1/2"
- --
- --
- --
40
FLOOR TROUGH
- --
- --
- --
a
CONVECTION OVEN W /WORKTOP
3/4"
- --
- --
- --
- --
- --
40 MBH
46
BRAISING PAN
- --
- --
- --
- --
- --
- --
ROUTE DRAIN TO INDIRECT DISCHARGE AT TROUGH
a
KETTLE FILLER FAUCET (2)
- --
1/2"
1/2"
- --
- --
- --
48
KETTLE STAND
- --
- --
- --
- --
I.W.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
49
FLOOR KETTLE
1/2"
___
15 MBH. ROUTE DRAIN
FLOOR TO TROUGH INDIRECT DISCHARGE AT
Go
PASTA TABLE W/ SINK
- --
- --
- --
1 -1/2"
- --
- --
58
BIG FLOW FAUCET
- --
3/4"
3/4"
- --
- --
- --
61
KETTLE STAND
- --
- --
- --
° --
LW.
- -°
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
62
DOUBLE JOINT FAUCET
- --
1/2"
1/2"
- --
- --
-- -
64
RANGE (COUNTER TOP)
3/4"
- --
- --
- --
- --
- --
80 MBH
65
GRIDDLE
3/4"
- -_
- --
- --
- --
- --
40 MBH
69
CHEESE MELTER
3/4"
- --
- --
- --
- --
- --
40 MBH
.
CONVECTION OVEN
3/4"
- --
- --
- --
- --
- --
115 MBH
82
COOLER EVAPORATOR COIL
- --
- --
- --
- --
LW.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
88
FREEZER EVAPORATOR COIL
- --
- -_
___
___
I,W,
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
93
BREAD WARMER WELL
- --
- --
- --
- --
I.W.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
100
HOT WELLS
- --
- --
1/2"
- --
I.W.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
(101
HOT WELLS
- --
- --
1/2"
- --
LW.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
106
PASTA COOKER (2)
3/4"
1/2"
1/2"
- --
I.W.
- --
150 MBH (EA.)
120
DBL JOINT FAUCET - PASTA
- --
- --
1/2"
- --
- --
- --
SEE FIXTURE SCHEDULE S -1.
126
DIPPER WELL ASSEMBLY
- --
- --
1/2"
- --
I.W.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
SOUP WELL (2)
- --
- --
- --
- --
LW.
_ -_
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
TEA BREWER
139
SODA DISPENSER
- --
1/2"
___
___
_ --
___
140
LEMONADE DISPENSER
----
1/2"
---
___
___
___
0
COFFEE MAKER (2)
- --
1 /2"
- --
- --
- --
- --
143
SINK
- --
- --
- --
1 -1/2"
- --
- --
144
SINK FAUCET
- --
1/2"
1/2"
___
___
___
150
CARBONATORS
- --
1/2"
- --
- --
- --
- --
iD
DRAIN BOARD
- --
- --
- --
- --
LW.
- --
4
ICE BIN
° °°
°-
° °°
_ °°
I.W.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
4- COMPARTMENT SINK
- --
- --
- --
1 -1/2"
- --
- --
a
4 -COMP. SINK FAUCET
- --
1/2"
1/2"
- --
- --
___
156
DOUBLE JOINT FAUCET
- --
1/2"
1/2"
- --
- --
- --
159
HAND SINK
- --
- --
- --
1-1/2"
- --
- --
160
SINK FAUCET
- --
1/2"
1/2"
- --
- --
- --
INSTALL WITH MV -2
161
BLENDER STATION W /DUMP (2)
- --
- --
- --
- --
I.W.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
162
BLENDER SINK FAUCET (2)
- --
1/2"
1/2"
- --
- --
- -_
169
_ ICE BIN
- - -
--
- --
- --
I.W.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
e
DRINK RAIL
- --
- --
- --
- --
LW.
- --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
070
SINK
-- -
___
- -.
1 -1/2"
___
_ -
a
SINK FAUCET
- --
1/2"
1/2"
- --
- --
- --
180
HOT WELLS
- --
- --
- --
- --
LW.
-- -
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
184
LEMONADE DISPENSER
- --
1 /2"
- --
- --
- --
- --
186
TEA BREWER
- - --
1 /2"
- --
- --
- --
- --
187
COFFEE MAKER
- --
1 /2"
- --
- --
- --
- - --
188
SODA DISPENSER
190
REMOTE CARBONATORS (3)
- --
1 /2"
- --
- --
- --
- --
199
BEER COOLER EVAPORATOR COIL
- --
- --
- --
- --
I.W.
_ --
ROUTE DRAIN TO INDIRECT WASTE RECEIVER
204
BOOSTER HEATER
1"
_ --
- --
___
___
___
200 MBH (WITH RE- CIRCULATION KIT)
PLUMBING FIXTURE SCHEDULE
SYMBOL
DESCRIPTION
CONNECTION
W
V
CW
HW
ET -1
EXPANSION TANK: WELDED STEEL CONSTRUCTION, DIAPHRAGM TYPE, PRE-
PRESSURIZED, 4.8 GALLON VOLUME, 3 GALLON ACCEPTANCE.
AMTROL ST -12 (ASME)
- --
- --
1"
- --
FD -1
FLOOR DRAIN: CAST -IRON BODY WITH ADJUSTABLE ROUND POLISHED
NICKEL BRONZE TOP. STRAINER DIAMETER 6 ". VANDAL -PROOF SCREWS.
PROVIDE WITH TP -1.
J.R. SMITH 2005 -A.
SEE
DWGS.
SEE
DWGS
- --
- --
FS -1
FLOOR SINK: 12 -1/2" SQUARE TOP, 8" DEEP, HEAVY CAST -IRON WITH ACID
RESISTANT COATING INTERIOR, ALUMINUM DOME BOTTOM
STRAINER, PRIMED.
COMMERCIAL ENAMEL NO. 906 -6
(NOTE: VERIFY GRATE REQUIREMENTS WITH KITCHEN CONSULTANT PLANS)
3"
2 "___
_ -_
FS-2
FLOOR SINK: 12 -1/2" SQUARE TOP, 10" DEEP, HEAVY CAST -IRON WITH ACID
RESISTANT COATING INTERIOR, ALUMINUM DOME BOTTOM
STRAINER, PRIMED.
COMMERCIAL ENAMEL NO. 906 -10
(NOTE: VERIFY GRATE REQUIREMENTS WITH KITCHEN CONSULTANT PLANS)
3"
2"
HB -1
HOSE BIBS, TRASH ROOM: ACORN 8156
_ --
- --
3/4"
3/4"
L -1
LAVATORY: WALL HUNG, VITREOUS CHINA, 20 "x18 ", FRONT OVERFLOW,
SOAP DEPRESSION, FAUCET HOLES ON 4" CENTERS.
CONCEALED ARMS, AMERICAN STANDARD 0355.012 "LUCERNE"
FITTINGS: 1 -1/4" x 1 -1/2" P -TRAP. SUPPLIES AND STOPS.
CARRIER: FLOOR MOUNTED WITH CONCEALED ARMS, J.R. SMITH, AS APPLICABLE.
FAUCET:INFRARED SENSOR, 120 VAC/ 6 VDC PLUG -IN TRANSFORMER (SLOAN SFP -6),
4" CENTERS, 3/8" O.D. COPPER TUBE INLETS, VANDAL - RESISTANT 0.5 GPM AERATOR,
NO LIFT ROD HOLE, POLISHED CHROME FINISH GRID STRAINER. INSTALL WITH MV -2
SLOAN EBF -650, CHROME FINISH
1-1/2"
1-1/2"
1/2"
1/2"
L -2
LAVATORY: COUNTERTOP, VITREOUS CHINA, 20 IN. BY 17 IN, OVAL
ADA COMPLIANT, FRONT OVERFLOW, SELF - RIMMING, 4 IN. CENTERS.
AMERICAN STANDARD 0476.028 "AQUALYN"
FITTINGS: 1 -1/4" x 1 -1/2" P -TRAP. SUPPLIES AND STOPS.
., , . - -
1-1/2"
-
1-1/2"
1/2"
1/2"
MS -1
MOP SINK: FLOOR MOUNTED, 28 IN, X 28 IN., CORNER TYPE,
ACID - RESISTANT, MOLDED STONE,
MUSTEE 63M
FAUCET: HOSE -END SPOUT TYPE WITH INTEGRAL VACUUM
BREAKER, ADJUSTABLE ARMS WITH INTEGRAL STOPS, AND WALL
BRACE. CHROME.
2"
1 -1/2"
1/2"
1/2"
MV -2 MIXING VALVE: 120'F INLET, 110'F DELIVERY, POINT OF USE TYPE.
ROUGH CHROME FINISH, 1/2" NPT
POWERS E480 -01
- --
- --
3/4"
3/4"
CP -1 HOT WATER RECIRCULATING PUMP: BELL AND GOSSETT "LITTLE RED"
#LR -15 WITH BRONZE BODY. 120V,1PH, 1/12 HP MOTOR.
- --
- ---
- --
3/4"
CP -2 HOT WATER RECIRCULATING PUMP: BELL AND GOSSETT "LITTLE RED"
#LR -15 WITH BRONZE BODY. 120V,1PH, 1/12 HP MOTOR.
- --
- --
-- ----
3/4"
PF -1
,.,�`�_.
BP -1
POT FILLER FAUCET: BRASS BODY, SINGLE WATER INLET,
18" DOUBLE - JOINTED SPOUT, QUARTER -TURN RENEWABLE CARTRIDGE,
POLISHED CHROM FINISH.
CHICAGO 515 -CP
- --
- --
-- --
1/2"
REDUCED PRESSURE BACKFLOW PREVENTER: CARBONATOR, STEAMER:
__-
- --
1/2"
___
A
TP -1 TRAP PRIMER. PPP PR -500, "PRIME RITE"
- --
- --
qw-
1/2"
___
U -1 URINAL: SIPHON JET, VITREOUS CHINA, WALL MOUNTED,
3/4 IN. TOP SPUD. MOUNTING HEIGHT STANDARD.
KOHLER K- 5016 -ET "DEXTER"
FLUSH VALVE: 1.0 GAL. PER FLUSH, TOP SPUD.
SLOAN OPTIMA PLUS 8186 -1 (INFRARED SENSOR /BATTERY)
CARRIER: FLOOR MOUNTED.
J.R. SMITH 0600 SERIES URINAL SUPPORT WITH SUPPORTING STUDS
AND BOTTOM BEARING PLATE.
2"
1 -1/2"
3/4"
_ -_
U -2 URINAL: SAME AS U -1 ACCEPT MOUNTED AT SPECIAL MOUNTING HEIGHT
FOR ADA COMPLIANCE.
2"
1 -1/2"
3/4"
__-
WH -1 WATER HEATER: GAS FIRED, 95% EFFICIENCY, AIR INTAKE AND EXHAUST,
WH -2 199 MBH INPUT, 230 GPH RECOVERY AT 100'F TEMPERATURE RISE,
DRAIN VALVE, T &P VALVE, AQUASTAT AT CIRCULATION PUMP,
W /INTERMITTENT ELECTRONIC IGNITION, 115V, 1 PH, 60Hz,
100 GAL. FACTORY INSULATED, 1,424LBS. (WET), ASME RATED STORAGE TANK.
PIPING SHALL BE PER MANUFACTURER'S RECOMMENDATION.
A.O SMITH 8TH 199
- --
- --
1 -1/2"
1 -1/2"
WC -2 WATER CLOSET: SAME AS WC -1 BUT ADA MOUNTING HEIGHT.
KOHLER, K -4330
3"
2"
1"
- --
PLUMBING EQUIPMENT SCHEDULE
SYMBOL
DESCRIPTION
ELECTRICAL
CP -1
HOT WATER RECIRCULATION PUMP: BELL AND GOSSET "LITTLE RED"
#LR -15BWR WITH BRONZE BODY.
1/12 HP
120 V
1 PHASE
WH -1
WH-2
WATER HEATER: GAS - FIRED, 95% EFFICIENCY, AIR INTAKE AND EXHAUST,
DRAIN VALVE, T & P VALVE, AQUASTAT AT CIRCULATION PUMP W /ELECTRONIC IGNITION
100 GAL. FACTORY INSULATED, 1424LBS. (WET), ASME RATED STORAGE TANK,
199 BTUH INPUT, 230 GPH AT 100'F RISE.
A.O. SMITH, BTH -199
115 V
1 PHASE
60 Hz.
FILE: 0497P0.11.DWG - P0.11 I EDIT: 12/23/2008 3:30 PM BY VICTORIAN I PLOT: 12/23/2008 3 :47 PM BY QUINLAN BELOG
Rai WNW t-u
COMPLIPICE
AP! •` * °VIE
FEB 2 0 2E fl9
?GO8 z78
1 ONION
C4S$ C°nl! A
DEC 2 6 /NH
PERMIT CENTER
4 INTERFACE
ENGINEERING
Contact
Victoria Haynes
Project
2008 -0497
708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204
PIIONE 503.382.2266 TAX 503.382.2262
P elc
arc ffiecture
2525 t aut N.. rro,t;o
Portland, OR 57214
503 996 3617 prhon
503,225.3715 fQ x
THE OLD
SPAGHETTI
FACTORY
SOUTHCENTER SQUARE
TUKWILA, WASHINGTON
SCHEDULES — PLUMBING
Job No: 0826
File Name:
Date: 12/17/08
Rev:
CITY REVIEW COMMENTS
Sheet No:
P0.11
:4
140 142
1.101
J; 3»
....................
ES -1
WC
L �__
12 "
' 1:
;
FILE: 0497P2.00.DWG — P2.00 EDIT: 1/22/2009 4: 30 PM BY TODDS I PLOT: 1/22/2009 5: 09 PM BY TODD SI•4OOTE
3"
' I ,
!i
i!
a
1
FR--1
FS -2
SCALE: 1/4
8
4
ES -2
3 "
r --
a
- 2"
.:..... ....... ........................
FIRST FLOOR PLAN -PLUMBING - WASTE /VENT
r: •.. ..
2 "
Apo
IWCO
2 "
Of
"if fi r
-4; 4 1 _gip ♦ 4 , '
I, I I D -1 s �� ��
l
t t
4 1
GI —3
3
FS--2
-3
1:
D
0
0
4
E
0
0
0
10
SHEET KEYNOTES
INSTALL FS -1 OR FS-2 AS INDICATED AND
PROVIDE INDIRECT WASTE PIPING FROM
EQUIPMENT TO AIR GAP DISCHARGE. VERIFY
EXACT SIZE AND LOCATION OF FLOOR SINK
AND INDIRECT DRAIN WITH EQUIPMENT
SUPPLIER PRIOR TO ROUGH —IN,
ROUTE PVC PIPING BELOW SLAB FOR FUTURE
INSTALLATION OF BEVERAGE /BEER TUBING
BY LOCAL VENDOR. INSTALL PVC PIPING
USING EXTRA LONG SWEEP ELBOWS.
COORDINATE EXACT ROUTING WITH
ELECTRICAL, MECHANICAL, STRUCTURAL. SEE
3/P3.01
PROVIDE INSULATED REFRIGERATION COIL
CONDENSATE DRAIN PIPING AND COORDINATE
ALL NECESSARY WALL PENETRATIONS WITH
EQUIPMENT SUPPLIER. ROUTE SAME SIZE AS
CONNECTION SIZE. SLOPE TO DISCHARGE
LOCATIONS AS REQUIRED.
ROUGH —IN WASTE AND VENT PIPING AS
REQUIRED FOR CONNECTION TO OWNER
SUPPLIED /CONTRACTOR INSTALLED FIXTURE.
VERIFY ROUGH --IN REQUIREMENTS WITH
KITCHEN CONSULTANTS FIXTURE SCHEDULE.
SEE SHEET P1.0.
ISLAND VENT FIXTURE PER PLUMBING CODE.
OFFSET FOOT VENT BELOW FLOOR AS
SHOWN. SEE DETAIL 7/P3.01,
ROUTE VENT PIPING BELOW FLOOR, THEN UP
IN WALL AS SHOWN.
ROUTE DRAIN SAME SIZE AS OUTLET FROM
MAKE UP AIR UNIT DOWN THROUGH ROOF
AND ROUTE IN CEILING TO FLOOR SINK AS
SHOWN,
3 INCH WASTE PIPING UP, SEE 1/P2.02
FOR CONTINUATION.
2 INCH WASTE PIPING UP. SEE 1/P2.02
FOR CONTINUATION.
ROUTE WASTE FROM KITCHEN /BAR
EQUIPMENT TO INDIRECT DISCHARGE AT
FLOOR SINK.
CONNECT NEW WASTE PIPING TO EXISTING
WASTE PIPING BELOW FLOOR,
PROVIDE DRAIN PAN UNDER WASTE PIPING
ABOVE FOOD PREP AREAS AND SLOPE BACK
TO RISER LOCATION. SEE 1/P3.01.
VENT PIPING UP, SEE 1/P2.02 FOR
CONTINUATION.
Vial lat) rurt.
CO 1 E COMPLIANCE.
APP ' VED
FEB ?0 NI
City Onuldda
I.la NGOMSION
FGOB, 279
AV-MLA
JAN 2 8 2009
PERMIT CENTER
INTERFACE
w ENGINEERING
Contact
Victoria Haynes
Project
2008 -0497
708 8.W. ;RD AVE., SU1TE 400, PORT.L.ANI3, OR 97204
.PHONE 503.382.2266 FAX 503.382.2262
Rev:
THE OLD
SPAGHETTI
FACTORY
SOUTHCENTER SQUARE
TUKWLA, WASHINGTON
FIRST FLOOR PLAN
PLUMBING
WASTE/VENT
Job No: 0826
File Name:
Date: 01/22/09
CITY REVIEW COMMENTS
CITY REVISIONS
CORRECTION
LTR#
Sheet No:
P2.00
GI
\. ..
"< „
Nom.
111111 (tiiiiH11111
E111111i11 1111 3 Il ` 4r 1 Il
fl 1111 __1111
111112466 1111
l lffIN111 11111f 111 11i 1111111
X1.11 € 1111 I'111111C1f111L11 IlIf1(111111
1244811 i[111[11111111 24.361}1E, i ;(
1[l _ 111111iI[lll E11`llil 11 111[111 811111[
lE ;s
FS -2 O
FS -1
WCO
GI
PP
in
I
L
FS -1
/ t
t
// // ,, ' . N • . `
\. ".. "\
/
/ / \ ." \. "\ ° \
Fr ..
I,
(
f
WCO
3"
FILE: 0497P2.00.DWG - P2.00 I EDIT: 12/23/2008 2 :38 PM BY VICTORIAH I PLOT: 12/23/2008 3 :47 PM BY QUINLAN BELOG
ES -1
i
am(
H
ED -1
FS -2
0
1 FIRST FLOG
0 2' 4'
SCALE: 1/4"=1'-0"
8'
FS -2
I
H
1
CO
r
rr
L
iftts\
1
PLAN - PLUMBING-WASTE/VEN
WCO
CL
(
WC
4"
2"
3"
FS- 2
(TYP.)
FS-2 n
1
6"1
4
GI
F
FS -2
T r --- -_
_
WCO (TYP. 13)
FS- 2
ES- 2
1
SHEET KEYNOTES
N,
U
10
11
12
13
INSTALL FS -1 OR FS -2 AS INDICATED AND
PROVIDE INDIRECT WASTE PIPING FROM
EQUIPMENT TO AIR GAP DISCHARGE. VERIFY
EXACT SIZE AND LOCATION OF FLOOR SINK
AND INDIRECT DRAIN WITH EQUIPMENT
SUPPLIER PRIOR TO ROUGH -IN.
ROUTE PVC PIPING BELOW SLAB FOR FUTURE
INSTALLATION OF BEVERAGE /BEER TUBING
BY LOCAL VENDOR. INSTALL PVC PIPING
USING EXTRA LONG SWEEP ELBOWS.
COORDINATE EXACT ROUTING WITH
ELECTRICAL, MECHANICAL, STRUCTURAL. SEE
3/P3.01
PROVIDE INSULATED REFRIGERATION COIL
CONDENSATE DRAIN PIPING AND COORDINATE
ALL NECESSARY WALL PENETRATIONS WITH
EQUIPMENT SUPPLIER. ROUTE SAME SIZE AS
CONNECTION SIZE. SLOPE TO DISCHARGE
LOCATIONS AS REQUIRED.
ROUGH -IN WASTE AND VENT PIPING AS
REQUIRED FOR CONNECTION TO OWNER
SUPPLIED /CONTRACTOR INSTALLED FIXTURE.
VERIFY ROUGH -IN REQUIREMENTS WITH
KITCHEN CONSULTANTS FIXTURE SCHEDULE.
SEE SHEET P1.0.
ISLAND VENT FIXTURE PER PLUMBING CODE.
OFFSET FOOT VENT BELOW FLOOR AS
SHOWN. SEE DETAIL 7/P3.01.
ROUTE VENT PIPING BELOW FLOOR, THEN UP
IN WALL AS SHOWN.
ROUTE DRAIN SAME SIZE AS OUTLET FROM
MAKE UP AIR UNIT DOWN THROUGH ROOF
AND ROUTE IN CEILING TO FLOOR SINK AS
SHOWN.
3 INCH WASTE PIPING UP. SEE 1/P2.02
FOR CONTINUATION.
2 INCH WASTE PIPING UP. SEE 1/P2.02
FOR CONTINUATION.
ROUTE WASTE FROM KITCHEN /BAR
EQUIPMENT TO INDIRECT DISCHARGE AT
FLOOR SINK.
CONNECT NEW WASTE PIPING TO EXISTING
WASTE PIPING BELOW FLOOR.
PROVIDE DRAIN PAN UNDER WASTE PIPING
ABOVE FOOD PREP AREAS AND SLOPE BACK
TO RISER LOCATION. SEE 1 /P3.01.
VENT PIPING UP. SEE 1/P2.02 FOR
CONTINUATION.
G
CODE COMP LO
PROVED FEB 2.0 •lifjl"
Ca alb i
i U 0 SION
8 - z78
04
DEC 2 6 2008
PERMIT CENTER
INTERFACE
E N G I N E E R I N G
Contact
Victoria Haynes
Project
20080497
708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204
PHONE 503.382.2266 FAX 503.382.2262
arc I l ' I r
Date:
Rev:
2525 t st Burnuide �y €.
Portland, OR 07214
603.226.3e617 phono
s03.226,3'71> fi.m
THE OLD
SPAGHETTI
FACTORY
SOUTHCENTER SQUARE
TUKWILA, WASHINGTON
FIRST FLOOR PLAN
PLUMBING
WASTE /VENT
Job No:
File Name:
0826
MEM
12/17/08
/ \ CITY REVIEW COMMENTS
LL_P
Sheet No:
P2.00
r-
EXSITING 2"
DOMESTIC COLD
WATER LINE
I I I
±H 1 111 h-} N
j[l11'lli011[ 1 1]11 1 1 `1111' IlL111 1119'If 1111 111111 111ll(...11E1111111 Il'
1 1111111 011111=' -1 11111] 110111111 1111' 4 I )( [It]fIJIILI111
[C'1`lll, 1111 1 1 [1G[rJ11L[1111Iffli1!11!Ll,1'l11 f1'l1l_ _
1
���orC }1[[111 ij[j (111 1111111111 11[I 1' li 111117111[
• C1111 1111[ 1.111,1 [ I1111111I�� 1111111111V11_,1111 � �1 1 � 1 I I]L[ �ilIII,
�_.. � 0111�:I 1�1 [1lV�. l�l1[
I + 1
1-1/2" (2633 MBH)
FILE: 0497P2.01.DWG — P2,01 I EDIT: 10/31/2008 1:40 PM BY RACHELD I PLOT: 10/31/2008 3:35 PM BY RACHEL DEFOURI
1 -1/4"
1/2"
IMO
SCALE: 1/4"=V-0"
144
MBH
40
MBH
0
80
MBH
[11 1111'1111,11111
I' � LI 1 11 1
1/2"
1/2"
1/2"
-v vl
tA
2
1-1/2"
1/2"
i co
1-1/4"
t
1 FIRST FLOOR PLAN - PLUMBING -WATER /GAS
0 2' 4' 8' '.
15
MBH
1/2"
n
EL
1/2"
1
'I
2"
3/4"
1/2"
3/4
1/2"
3/4
'
0Q uc �
0
8
[--
J..
`i 3
SHEET KEYNOTES
Q ROUTE GAS SUPPLY LINE TO SECOND FLOOR.
SEE 1/P2.02 FOR CONTINUATION.
0 ROUTE GAS SUPPLY LINE IN WALL FOR
CONNECTIONS TO KITCHEN EQUIPMENT.
REFER TO KITCHEN DRAWINGS FOR EXACT
REQUIREMENTS AND CONNECTION SCHEDULE
ON P0.01. PROVIDE GAS COCK, UNION AND
FLEXIBLE CONNECTION.
10
11
12
13
14
15
PROVIDE GAS COCK, FIRE SAFETY
SHUT —DOWN SOLENOID VALVE, WITH UNIONS,
IN NON — CONCEALED ACCESSIBLE LOCATION,
FOR GAS SERVICE TO GAS FIRED COOK LINE
KITCHEN EQUIPMENT. INTERLOCK SOLENOID
WITH HOOD FIRE SUPPRESSION SYSTEM.
ROUTE 1/2" COLD WATER SUPPLY IN WALL
FOR CONNECTION TO CARBONATOR. ALL
PIPING DOWNSTREAM OF THE BACKFLOW
PREVENTER IS TO BE NSF APPROVED
PLASTIC PIPE. COPPER PIPE IS NOT
ALLOWED.
ROUTE HOT AND /OR COLD WATER SUPPLY
DOWN IN WALL FOR ROUGH —IN AND
CONNECTION TO KITCHEN EQUIPMENT. VERIFY
EXACT SIZE AND ROUGH —IN REQUIREMENTS
WITH KITCHEN EQUIPMENT SCHEDULE.
INSTALL BACKFLOW PREVENTER ALONG WALL
ON UNI —STRUT MOUNTING CHANNEL AT
MAXIMUM 5' -0" ABOVE FINISHED FLOOR.
ROUTE DRAIN TO NEAREST FLOOR SINK OR
SERVICE SINK.
ROUTE 1/2" COLD WATER SUPPLY DOWN TO
WATER FILTER. ROUTE WATER FROM FILTER
TO ICE MAKER ALONG WALL, PROVIDE
SHUT —OFF VALVE.
ROUTE HOT AND /OR COLD WATER PIPING
DOWN IN WALL TO BELOW GRADE,
ROUTE WATER SUPPLY UNDER COUNTER AND
UP TO FIXTURE.
ROUTE FILTERED COLD WATER TO KITCHEN
EQUIPMENT.
ROUTE WATER PIPING UP TO SECOND FLOOR
SEE 1/P2.02 FOR CONTINUATION.
ROUTE 3/4 INCH 180' F WATER SUPPLY
DOWN TO DISHWASHER PROVIDE PRV. SEE
9/P3.0.
ROUTE WATER SUPPLY FROM BACKFLOW
PREVENTER.
CONNECT NEW WATER PIPING TO EXISTING
WATER PIPING IN CEILING.
ROUTE WATER PIPING DOWN IN WALL. ROUTE
HORIZONTALLY INSIDE WALL TO FIXTURES.
aitttU�
CODE COMPLIANCE
AP VE1
FEB 2 0 2009
laDINGDIViSIOit
p&o8z7
INTERFACE
�� ENGINEERING
Contact
Victoria Haynes
Project
2008 -0497
708 S.W. 3RD AVE., SUITE 400, POR'1'I.AND, OR 97204
PHONE 503.382.2266 FAX 503.382.2262
THE OLD
SPAGHETTI
FACTORY
SOUTHCENTER SQUARE
TUKWLA, WASI -NGTON
FIRST FLOOR PLAN
PLUMBING
WATER /GAS
Job No: 0826
File Name:
Date:
Rev:
10/31/08
RECEIVED
Nov nj 2008
PERMIT CENTEh
Sheet No:
P2.01
1....1........ <..........7 : :..•
............ . .
FILE: 0497P2.02.DWG - P2.02 1 EDIT: 12/23/2008 3:26 PM BY VICTORIAN 1 PLOT: 12/23/2008 3:48 PM BY QUINLAN BELOG
0 2' 4' 8'
SCALE: 1/4 " =1' -0"
1 SECOND FLOOR PLAN - PLUMBING
SHEET KEYNOTES
• ROUTE GAS SUPPLY LINE UP THROUGH ROOF
FOR CONNECTIONS TO ROOFTOP AC UNIT.
PROVIDE GAS COCK, PRESSURE REDUCING
REGULATOR AND UNION. VERIFY EXACT
EQUIPMENT REQUIREMENTS PRIOR TO
ROUGH -IN. SEE 2/P3.01.
• ROUTE 2" COLD WATER SUPPLY IN WALL FROM
BELOW FLOOR AND MANIFOLD FOR CONNECTION
TO FIXTURE BANK. PROVIDE SHUT -OFF VALVE
AND SHOCK ARRESTOR WITH ACCESS.
✓ ROUTE HOT AND /OR COLD WATER PIPING IN
WALL FROM BELOW FLOOR AND MANIFOLD FOR
CONNECTION TO FIXTURES.
PROVIDE SEISMIC BRACING IN ACCORDANCE
WITH CODE AND AUTHORITY HAVING
,JURISDICTION. SEE 5/P3.01.
INSTALL TRAP PRIMER IN WALL IN ACCESS
PANEL AND ROUTE PIPING BELOW FLOOR TO
FLOOR DRAINS IN RESTROOMS.
• VENT PIPING FROM BELOW.
a7 INSTALL GAS REGULATOR TO REDUCE FROM 2
PSI TO 6" W.C. AND ROUTE VENT TO OUTSIDE
• HOT AND /OR COLD WATER PIPING DOWN TO
FIRST FLOOR. SEE P2.01 FOR CONTINUA
?GOB
Cat
APPROVE'
3 20 7 `'''
C ,
ILO NG DIVISION
CITYOF
DEC 2 6 2008
PERMIT CENTER
INTERFACE
E N G I N E E R I N G
Contact
Victoria Haynes
Project
2008 -0497
708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204
PHONE 503.382.2266 FAX 503.382.2262
MI a I e,
2525 Eaut 1: U3'0S9d0 SL
Portland, OR 07214
503 )'8 3617 44001:.
503 26 1715 fax
THE OLD
SPAGHETTI
FACTORY
SOUTHCENTER SQUARE
TUKWILA, WASHINGTON
I.1_P
i78 SECOND FLOOR PLAN — PLUMBING
Job No: 0826
File Name:
Rev:
Date: 12/17/08
n CITY REVIEW COMMENTS
Sheet No:
P2.02
N
1-1/4" G
FILE: 0497P2.03.DWG — P2.03 I EDIT: 10/31/2008 1: 52 PM BY RACHELD I PLOT: 10/31/2008 3:35 PM BY RACHEL DEFOURI
MAU -1
405 MBH
1-1/2" G
1 ROOF PLAN - PLUMBING
0 2' 4' 8'
SCALE: 1/4"= V-0"
12
AC -3
180 MBH
3/4" G
1 3 •
0
A
SHEET KEYNOTES
�1 DAYLIGHT CONDENSATE DRAIN TO SPLASHBLOCK
ON ROOF.
® ROUTE GAS PIPING FROM BELOW TO ROOF TOP
HVAC UNIT. PROVIDE UNION, GAS COCK AND
REGULATOR.
ilt
C DD O `n� Y COMPU`CC
APPROVED
fEB 20 21 c
atyCirrawila
INTERFACE
ENGINEERING
Contact
Victoria Haynes
Project
2008 -0497
708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204
PHONE 503.382.2266 FAX 503.382.2262
THE OLD
SPAGHETTI
FACTORY
SOUTHOENTER SQUARE
TUKWLA, WASF- EvGTON
ROOF PLAN — PLUMBING
Job No: 0826
File Name: —
Date: 10/31/08
Rev:
RECEIVED
NOV fl 6 2008
PERMIT CENTEF
Sheet No:
P2.03
SIZE
TANK HGT ABOVE FLOOR
NO. OF STRAPS
LOCATION
66 GAL OR LESS
12" OR LESS
1
BETWEEN TOP 1/3 AND
1/2 OF TANK
66 GAL OR LESS
MORE THAN 12"
2
TOP —IN TOP 1/3 OF TANK
BOTTOM -3" ABOVE OR BELOW
ACCESS PANEL
66 GAL TO 100
12" OR LESS
2
TOP —IN TOP 1/3 OF TANK
BOTTOM -3" ABOVE OR BELOW
ACCESS PANEL
66 GAL TO 100
MORE THAN 12"
3
TOP —IN TOP 1/3 OF TANK
BOTTOM -3" BELOW ACCESS
PANEL
MIDDLE — CENTER OF TANK
SECURE STRAP -'
1 DRAIN PAN SECTION DETAIL
ROOFING
fi
NO SCALE
ROUTE PIPING UP THRU
ROOF WITH —IN THE PERIMETER
OF THE MOUNTING CURB.
MINIMUM 4" OVERLAP
NO SCALE
VERIFY VERTICAL
CLEARANCE WITH
SUPPLIED EQUIPMENT
ANA FS DRAWINGS
(6 AFF TYPICAL
COORDINATE EXACT ROUTING
W /STRUCTURAL AND WASTE
PIPING CONDITIONS PRIOR
TO ROUGH IN
SEE SHEET P2.00
SEE FLOOR PLAN
FOR CONTINUATION
NO SCALE
SEE ARCHITECHTURAL DRAWINGS
FOR EXACT INFORMATION &
DETAILS ON ROOFING SYSTEM
PIPE ROOF PENETRATION
NOTE:
TYPICAL FOR BOTH
ENDS OF SYSTEM
3 SLEEVE FOR SODA SYSTEM
MINIMUM DISTANCE IS
10x PIPE DIAMETER.
WASTE PIPING
SECURE STRAP
SLOPE PER WASTE PIPING
SHEET METAL PAN ALL
BENDS /TURNS TO BE
WATER TIGHT CONNECTION
LEAD FLASHING (3LB.)
FLASHING TO ROOF
SODA LINES BY OTHER
f
4" PIPE NIPPLE
SEDIMENT TRAP
4 GAS PIPE CONNECTION
NO SCALE
SOLDER LEAD COUNTER FLASHING
COLLAR TO COUPLING
CAP PROVIDE HOLES IN
CAP FOR SODA LINES
4" AND /OR 6" PVC LONG SWEEP ELBOW
PRESSURE REGULATOR.
VENT TO ATMOSPHERE
1/4" PIPE
PLUG (TYP. 2).
UNION.
TO EQUIP.
FILE: 0497P3.01.DWG — P3.01 I EDIT: 10/31/2008 1:54 PM BY RACHELD I PLOT: 10/31/2008 3 :36 PM BY RACHEL DEFOURI
120'F HOT WATER
RETURN.
AQUASTAT
CP -1
1 -1 2" 120'F
HO WATER SUPPLY
1 -1/4"
GAS COCK
(TYP.)
PRESSURE
REGULATOR
(TYP.)
1 -1/4" (TYP.)
NOTE: MAINTAIN CLEARANCES TO COMBUSTIBLES AS REQUIRED BY MANUFACTURER.
UTILIZE NON COMBUSTIBLE MATERIAL AS SPACER.
T
DRIP LEG (TYP.)
SECURE CHANNEL
TO WALL STRUCTURE
AS REQUIRED.
(TYPICAL)
NO SCALE
EARTHQUAKE BRACING (WATER
HEATERS AND STORAGE TANKS)
SHUTOFF VALVE
(TYP.)
DISCHARGE FULL
SIZE TO FLOOR
DRAIN (TYP.)
1 -1/2"
FIXTURE
NO SCALE
WCO
NO SCALE
WCO
FLOOR
140'
THERMOMETER
(TYP.)
1-1/2"
WALL
AT WATER HEATER AND STORAGE
TANKS PROVIDE "SPACE MAKER"
BRAND SEISMIC RESTRAINT SYSTEM
(OR APPROVED EQUAL). SYSTEM
TO MEET REQUIREMENTS FOR
ZONE 4 SEISMIC INSTALLATIONS.
tH -- ET -1,
EXPANSION
TANK.
6 WATER HEATING SYSTEM
FLOOR
MINIMUM
MANUFACTURER
CLEARANCE
WALL
BOOSTER HEATER
WCO
—SLOPE 2%
FOOT VENT
7 ISLAND VENT DETAIL
TYP.
)!
185'R
BY KITCHEN
CONTRACTOR
185'
CHECK STOP
(TYP.)
TRAP SEAL TO
BE 2X TOTAL
STATIC
PRESSURE
ROOF
2" DOMESTIC COLD
WATER SUPPLY.
CHECK VALVE (TYP.)
8 DISHWASHER CONNECTION DETAIL
NO SCALE
3/4
THERMOMETER WITH
WELL (40'- 240'F)
CHECK VALVE
PRESSURE REDUCING VALVE
WITH INTERNAL BACK PRESSURE
RELIEF —WATTS OR EQUAL
020 P.S.I.
NOTE:
1. TRAP PIPING TO BE SAME SIZE AS AC UNIT DRAIN.
2. DRAIN PIPING TO BE COPPER OR ALTERNATE
MATERIAL APPROVED BY LOCAL CODES.
180' HW FROM BOOSTER
HEATER SEE P2.01 FOR CONT.
180' HWR TO BOOSTER
HEATER RECIRC SYSTEM.
STRAINER
SHOCK ARRESTOR
DISHWASHER
9 CONDENSATE TRAP
NO SCALE
7 ROOFTOP AC UNIT
ENTER OUTLET OVER
SPLASH PLATE.
" MAX
ROVIDE FELT
WALK PAD
PLUG TYPICAL
GENERAL NOTES
A. CONTRACTOR TO VERIFY EXACT LOCATIONS, SIZES
AND CONDITIONS OF EXISTING PLUMBING SYSTEM
IN THE FIELD PRIOR TO INSTALLATION OF NEW
PIPING RELATED TO WATER HEATING UPGRADE FOR
THE FACILITIES.
B. INSULATE ALL WATER PIPING ASSOCIATED WITH
WATER HEATER FROM NEW CONNECTION TO
EXISTING WATER SERVICE IN THE ROOM.
C. SET NEW WATER HEATER TO PROVIDE 140 DEGREES
HOT WATER FOR DISHWASHER BOOSTER HEATER.
INSTALL MIXING VALVE TO REMAINING FIXTURES AND
SET AT 120 DEGREES.
D. INSTALL MIXING VALVES AT OR NEAR WATER
HEATERS.
E. SET AQUASTAT BELOW SET POINT OF MIXER.
F. PROVIDE HEAT TRAP ON HOT INLET OF MIXER IF
ABOVE WATER HEATER.
SHEET KEYNOTES
01 ROUTE 185' HOT WATER RETURN PIPING FROM
DISHWASHER TO CONNECT WITH BOOSTER HEATER
RE—CIRCULATION KIT PROVIDED BY KITCHEN
CONTRACTOR. CONNECT PER MANUFACTURER'S
RECOMMENDATIONS.
Q PRESSURE AND TEMPERATURE RELIEF VALVE
DISCHARGE FULL SIZE TO FD -1.
Q AIR INTAKE AND EXHAUST VENT SYSTEM BY HVAC
CONTRACTOR. ROUTE CONDENSATE FROM VENT TO
FLOOR DRAIN. TYPICAL
V SEE DETAIL 5/P3.01 FOR RECOMMENDED
EARTHEQUAKE BRACING OF EQUIPMENT.
K SEE P2.02 FOR CONTINUATION.
G-z7s
INTERFACE
ENGINEERING
Contact
Victoria Haynes
Project
2008-0497
708 S.W. 31{1) AVE., SUITE 400, PORTLAND, OR 97204
PHONE 503.382.2266 FAX 503.382.22
THE OLD
SPAGHETTI
FACTORY
SOUTHCENTER SQUARE
TUKWLA, WASI-INGTON
DETAILS — PLUMBING
Job No: 0826
File Name:
Date:
Rev:
10/31/08
RECEIVED
Nov 0 6 7000
PERMIT CENTEE
Sheet No:
P3.01