Loading...
HomeMy WebLinkAboutPermit PG08-283 - WESTFIELD SOUTHCENTER MALL - CHAMPSCHAMPS 1030 SOUTHCENTER PY PGO8-283 Parcel No.: 6364200010 Address: Suite No: Cit'"of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 1030 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -283 02/04/2009 08/03/2009 Tenant: Name: CHAMPS Address: 1030 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: JENNIFER MIRELES Address: PO BOX 1673 , LOMITA CA Contractor: Name: MANZCO PLUMBING Address: PO BOX 822964 , VANCOUVER WA Contractor License No: MANZCP *926B8 Phone: Phone: 310- 328 -6300 X105 Phone: 360 772 -8149 Expiration Date: 01/28/2010 DESCRIPTION OF WORK: PLUMBING FOR TENANT IMPROVEMENT Value of Plumbing /Gas Piping: Fees Collected: $5,000.00 $226.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 1 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 2 grease interceptors 0 0 Repair or alteration of water piping and /or water 1 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 1 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 0 Medical gas piping (6 +) inlets /outlets 1 1 Gas Piping 0 Gas piping outlets (0 -5) 0 1 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PGO8 -283 Printed: 02 -04 -2009 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -283 Issue Date: 02/04/2009 Permit Expires On: 08/03/2009 Permit Center Authorized Signature: I hereby certify that I have read and ex governing this work will be complied The granting construction o Signature: Date: O2, 941 t'o'} mi d this permit and know the same to be true and correct. All provisions of law and ordinances Eth, hether specified herein or not. mit does not presu'1 to give authority to violate or cancel the provisions of any other state or local laws regulating rmance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Date: O z- U� Print Name: M k mo,telz_LA This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -283 Printed: 02 -04 -2009 Parcel No.: 6364200010 Address: Suite No: Tenant: CHAMPS City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 1030 SOUTHCENTER MALL TUKW Permit Number: Status: Applied Date: Issue Date: PG08 -283 ISSUED 11/25/2008 02/04/2009 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -283 Printed: 02 -04 -2009 I hereby certify that I have this work will be complied The granting of this pernu construction o he perfor Signature: Print Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us read these conditions and will comply with them as outlined. All provisions of law and with, whether specified herein or not. does not presume to give authority to violate or cancel the provision of any other work ance of work. ordinances governing or local laws regulating doc: Cond -10/06 PG08 -283 Printed: 02 -04 -2009 Sent By: EXPRESS PERMITS is Faster ; CITY OF TUK1%?'11A Community Development Department Permit Center 6300 Southcenrer 81wd•, Suite 100 Fukwile, WA 98188: http :ll www,ci.tJjkwita, wa. us 3103280336; Nov -19 -08 9:34AM; PLUMING/GM YMPING PERK APPLICATION FO- (1 1 Applications and plans moat be complete in order :no be mad for plan review. Applications will not be accepted through the mail or by fax. "please Print** IxE A SO eW t *sue Neme: ___ ptupe tty tamers Name: S► knifing Addresski VN � � ( are Lai AvicrliA City Sntt King Co Assessor's Tax No..:: (4) i• •i 20 ',DO Suite Number : J Floor: New Tenant: ❑ .... Yes NNo Neute.:' Ml Address: - iu�eil Ada�835 �nvtt ?./T ;_ to '+Compiaty Nc. 'Melling Address: ?Contact Pew E-Mall Address: Contractor Registration Number: ces SRmc ZiP Fax Number l 3 tS 010 aS — Qv Day Telephone: Fax Number: Expiration Daze :, Zip Company Name' Mailing Address :1 Comer Person. .JC.4f VO14 V E-Maii Address:, ay Day Telephoto: CIA1 tO5 SUR'LU FaxNui ber: t,11 kk,3,,_ 9 Company Name: Mailing Address: sane Count t �: � .� p. —_ _ _ teW :.2144 515.)7-.59-g Fax. Number. U t t_fA . , 2.53 Page 1 en 4E8891990rr 9I :SI 8002/8I/It Sent By: EXPRESS PERMITS is Faster ; 3103280336; Nov-19-08 9:35AM; Page 3/3 PLUMBE4G AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E-Mail Address: Contractor Registration Number: Valuation of Plumbing work (conhactor's bid price): Valuation of Gas Piping work (contractor's bid price): S .11111■•■ ■ Scope of Work (please provide detailed infonnation):_ ...■■■■••■• ..■•■■.•••■•••■•• Building Use (per Int'l Building Code): Occupancy (per Intl Building Code): lJtiIfty Purveyor: Water: ..1.■■■•....••■•■••■•■ aq, sate zip Day Telephone: • •1,1=1,1•=11,.... Fax Number% Expiration Date; Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Bathtub or combination bathishoww Bidet Drinking Main or water cricks, hold) FOod-watte grinder, Wash fountain Gas piping outlets I 6 7"5 ej 1'1, I 1111M1 111 a 1 111 Lavatory 1111. vWentater heater andfor n Additional medical gas iservminnilediet:inaldautictsogutl:taranc topfor—ipitiveainspecxgogystr morn waato Repair or situation of water pretteat*enaintarceptor, *Wig it* nap and wig, piPing tuid/or water treating equipment except alit typo 4ftase CPAIlikatkaftwAppliagliaek an Li...V-2006 Pam* Applicatkadoc Ravii60 94006 Repair or alteration ofdtainage or vent POilat Page 5 of Sent By: EXPRESS PERMITS is F ter ; 43/ LtAlti d is oti 1 Yiy; 2 3103280336; Nov -25 -08 3:51PM; Ai ECCO Page 1/1 PAGE 01/01 Wee +D[ Corisrreedoa - hi all t e: s, s is c011ettueden mot= should be entered 5y the applicant This figure will be reviewed and is object to possible revision by the Peen ut.Center to comply with eurmtt fee schedule. Expiration of Plan Review - Applications for which no permit is issued within 110 days !Owing the date of applicetioo shall expire by limitation • The Build Official may ,grad one Or more extensions deb= for additional al periods irgt'eteeeding 90 days each. The extension shall be ttalueeted in ricotta$ and' justiftbte cause tlepptooitsueted. Section 1O5.31 Fatereatienel Banding Code (current edition). The Building Officio t'itty alb oneinteusitet eta* for m sddit}tlrt►til i$efiotnot'exC 18$180 days. The extension shell be requested In writing and justifiable cause demonstrated. Section 103.4.3 Unifonnileinbing COdeleittent edition). I UER BY CERTIFY THAT1 HAVE READ AND EXAMINED MS APPLICATION AND KNOW, SAME .TO BE TRUE UNDER PENALTY OF PBBJURY BY T11E 1 AWS OF /HE STATE OP WASHINGTON, AND 1 A;M AUT RQRLZSD TO APPLY FOR THIS PEX 4ff- BUNG t R OR AVM) AGENT: . Signature: A 4IAd 4, ��, Print Name mem;� � i. Wang 4I, Fate_ I/ /2- 51 t Wxabwa ernes- Appeask ea.rRneki000s.Peaiepgpitwdos4ec xe:yr.ee; Moe Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 1030 SOUTHCENTER MALL TUKW Suite No: Applicant: CHAMPS RECEIPT Permit Number: PG08 -283 Status: APPROVED Applied Date: 11/25/2008 Issue Date: Receipt No.: Initials: User ID: R09 -00191 JEM 1165 Payment Amount: $188.00 Payment Date: 02/04/2009 12:32 PM Balance: $0.00 Payee: RECON INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1110. 188.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.0 188.00 Total: $188.00 doc: Receipt -06 Printed: 02 -04 -2009 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: PG08 -283 Address: 1030 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 11/25/2008 Applicant: CHAMPS Issue Date: Receipt No.: R08 -03825 Payment Amount: $38.00 Initials: WER Payment Date: 11/25/2008 02:20 PM User ID: 1655 Balance: $188.00 Payee: MICHELLE WELCH TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1016 38.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 38.00 Total: $38.00 9928 11/25 9707 TOTAL 38.00 don. Rpm :tint-OR Printarl. 11- 25 -7MR INSPECTION RECORD Retain a copy with permit INSP ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION K' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project , ( ,4 I Aie�I;) Type of Ins ection: i-- /A/4? f Address: /030 /21'4/1 Date Called: Special Instructions: Date Wanted: Requester: Phone o: o5_ 2//7 - 6 / 'Approved per applicable codes. Corrections required prior to approval. COMMENTS: 3 Inspector: EJ $6 I REINSPECTION FEE RE p-. gat 6300 Southcenter Blvd., Rec,. ,t No.: Date. UIR . Prior to inspection, fee must be uite 100. Call to schedule reinspection. Date: 5,1:1411. Y.:Agents- .IAISPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: M (2 !�t'tyr�lI;vt Type of Inspectioo^�n: Address: ‘ ---\ .-..- Date Called: Special Instructions: 404- 1-7 ^- 1 ,- Date Wanted: .� ' C � m z P.r�r / Reque�er:I Ph ne6 i °' -772 '°' 53 1 L/ Y A r"- 1 ''tr.) Ys°_. Approved per applicable codes. orrections required prior to approval. COMMENTS: I ) \U7) W N. V4--1" - 1`,1 `ti tom.... `'` ‘ ---\ .-..- Y Y A r"- 1 ''tr.) Ys°_. ----)-7 1.:.�A-@ t- ( L ...4.7) C J `. r -9 aft :v r 0 r- S a : ----a TA ,A1Lv &e..t.— \Op..(sv.)(.it Inspector: Date: EINSPECTION FEE R QUIRED. P for to inspection, fee ust be Call to schedule reinspection. 6300 Southcenter Blvd., Suite 10 Date: INSPECTION NO. SPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Project: C '/ g Y!!i -L" Type of Inspection: ,""enri%% - i J f) d 6 Address- /4 -30 l/4 i '/ ,/fl Date Called: R 7( Special Instructions: _._.3 Date Wanted: .-2 ----5-- 5 ca.0 p.m. Requester: Phone No: „d -772 ' g/ Approved per applicable codes. ❑ Corrections required prior to approval. NTS: 4't'p 7/1.■/11,-: nspector: Date:, REINSPECTION FEE REQUIRED. ' "ior to inspection, fee ust be at 6300 Southcenter Blvd., Suite 100. all tuchedule rei spection. Re eipt No.: Date: 4o 0 Emphasis On Excellence December 18, 2008 Mr. Bill Rambo, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 RE: Champs Southcenter Mall 633 Southcenter Tukwila, WA 98188 M- Retail Job #0813130 Dear Mr. Allen Johannessen: M • Retail Engineering, Inc. This letter is in response to Plan Review dated December 2, 2008 regarding the above referenced project. Plumbing Item #1 Revise Plumbing Plan to show point of connections for new plumbing work. (sheets M2.0) This represents our understanding of your building department's required plan corrections. If I can be of further assistance, please call. Sincerely, Terry Leistikow INCOMPLETE P&oBZ83 750 Brooksedge Blvd. • Westerville, Ohio 43081 614 -818 -2323 • FAX 614- 818 -2337 • E -MAIL mretail @m- corporations.com An M•Corporation RECEIVED DEC 3 0 2008 PERMIT CENTER December 2, 2008 Jennifer Mireles PO Box 1673 Lomit, CA 90717 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Letter of Incomplete Application # 1 Development Permit Application PG08 -283 Champs — 1030 Southcenter Mall Dear Ms. Mireles, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on November 25, 2008 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department needs to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the following comments. 1. Provide a floor plan showing the plumbing location, layout and point of connections. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician Enclosures File: PG08 -283 P:\Permit Center\Incomplete Letters\2008\PG08 -283 Incomplete Ltr #1.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -283 PROJECT NAME: CHAMPS SITE ADDRESS: 1030 SOUTHCENTER MALL Original Plan Submittal X Response to Incomplete Letter # 1 DATE: 12 -30 -08 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Build �1� DR/Mon Public Works Fire Prevention Planning Division Structural n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 01 -06 -09 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved fl Approved with Conditions DUE DATE: 02 -03-09 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2-28-02 PERMIT COORD COPY �` PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -283 DATE: 11 -25 -08 PROJECT NAME: CHAMPS SITE ADDRESS: 1030 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Build) ; Division ic Woks NA. 12 -e2-O DETERMINATION OF COMPLETENESS: Complete ❑ -2 -05 Comments: Fire Prevention Structural (Tues., Thurs.) Incomplete Planning Division C ❑ Permit Coordinator ❑ DUE DATE: 12-02-08 Not Applicable Permit Center Use Onfy INCOMPLETE LETTER MAILED: Departments determined incomplete: LETTER OF COMPLETENESS MAILED: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required C REVIEWER'S INITIALS: No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12-30-08 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 12(2-9 Plan Check/Permit Number: PG08 -283 ® Response to Incomplete Letter # 1 O Response to Correction Letter # C' Revision # after Permit is Issued O Revision requested by a City Building Inspector or Plans Examiner Project Name: CHAMPS Project Address: 1030 SOUTHCENTER. MALL Contact Person ,v)t/) I.(A/ Phone Number: (0 k 105 Summary of Revision: tqA ■ Vumioti Y15 plan I'o clam t9t n-t o f coh ri_D c -i'on- RECEIVEY ary of tiP DEC 3°I PERMIT CENT ER Sheet Numbers): m Z • () "Cloud" or highlight all areas of revision including date of revisi© Received at the City of Tukwila Permit Center by: Entered in Permits Plus on a appIicationsltbrms- applications on line Created: 8 -13 -2004 Revised: vision submittal Untitled Page Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MANZCO PLUMBING 3607728149 PO BOX 822964 VANCOUVER WA 98682 CLARK Corporation RECON, INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602699643 ACTIVE MANZCP*926B8 CONSTRUCTION CONTRACTOR 1/28/2008 1/28/2010 PLUMBING UNUSED Business Owner Information Name Role Effective Date Expiration Date MANZHURA, MIKHAIL PRESIDENT 01/28/2008 Bond Amount MANZHURA, VLADIMIR SECRETARY 03/13/2008 70446928 MANZHURA, MARGARITA VICE PRESIDENT 01/28/2008 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 WESTERN SURETY CO 70446928 01/28/2008 Until Cancelled $6,000.00 01/28/2008 Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date FARMERS https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= MANZCP* 926B 8 02/04/2009 3/4' DRAIN FROM PAN /� 0.1 112' VENT % Y O2 3' SAN 2 2 SAN FGO 1 v2' 3' D 2' SUPPLY AIR SPIN -IN TAP. SEAL JOINTS IN ROUND RIGID TRUNK DUCT DUCT AND AT TAPS W/ MAIN SUPPLY To S.A. MAIN INSULATED ROUND DUCT ALL DUCT LINER FLANGED AND GASKETED JOINT TRANSVERSE EDGES TO E5E OR DUCT CONNECTION AND RE- COATED W/ ADHESIVE IN INFORCEMENT IN ACCORDANCE W/ ACCORDANCE W/ SMACNA SMACNA 2' W.G. CLASS, SEAL STANDARDS (TYP.) NON- GASKETED TRANS - VERSE JOINTS IN ACCORDANCE W/ 5h1ACNA CLASS 'C' (TYP.) I DATE: 10 -30 -08 JOB NO: 0813130 DRAWN: CHECKED: GROSS AREA: 5,535 SQ. FT. SALES AREA: 3,278 SQ. FT. <> AIR AUXILIARY FLOAT SHUT -OFF A.H.U. MIN. 3/4' COPPER III STRAP CLAMP SWITCH I DRAIN, Map IASIN� OR AS DIRECTED BY CODED NOTES - MAI DUCT 7 FLOW LLUME DAMPER (TYPICAL) F— POSITIONS ROUND FLEXIESLE DUCT CONNECTION, SAME SIZE AS DIFFUSER NECK SIZE (MAX. 5 FT.) WRE REQUIRED DAMPER TO BE PLACED PERPENDICULAR TO AIR STREAM THERMAL INSULATING BLANKET WHERE REQUIRED- AUXILIARY DRAIN PAN H UNDER A..U. MIN. 6 ' LARGER THAN A.H.U. 4 6" DEEP, SEAL ALL SEAMS WATERTIGHT IMPINIIIIIIMIllellint 'r CONDENSATE TRAP DEPTH TO EE I I/2 TIMES UNIT OPERATING STATIC PRES- SURE (MIN. 2') 3' / PROVIDE 45. _ _e_ VOLUME DAMPER LOCATION INTERNAL LINER OR EXTERNAL WRAP INSULATION ; __ WHERE ABOVE LAY -IN CEILING. PROVIDE W/ LOCKING QUADRANT - 0 © AS SPECIFIED i BRANCH DUCT—_____ [___7 - l ,r 18' LONG ORANGE MARKER TAPE / ATTACHED TO DAMPER TO IDENTIFY LaG,4TfaN 1AA,A 111111\ A Emphasis On Excellence M • Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 TEL: 614.818.2323 FAX: 614.818.2337 SUPPLY AIR \ CEILING DIFFUSER \ PLASTER FRAME AUX IL I r4 :Y DRAIN FAN SCHEMATIC • SANITARY STACK (NTS) Ego D IFFUSE : MOUNTING SCHEMATIC (NTS) ,4 TYPICAL SQUARE DUCT TAKE - OFF (NTS) u _I 00 00 NOTES- 1. PROVIDE ACCESS DOOR IN ADJACENT DUCTWORK FOR RESETTING DAMPER 2. DAMPER MUST EE SUPPORTED IN DRAFT STOP B Y SLEEVE AND RETAINING ANGLES, DAMPER MUST REMAIN IN PLACE IF DUCT COLLAPSES. SEAL BETWEEN DRAFT STOP AND SLEEVE SHALL E3E FIRE RATED MATERIAL, DAMPER SHALL BE ONE SIZE LARGER THAN DUCT SIZE. 0 3' SAN FGO EX-SAN- VANES PRE- ASSEMBLED ON RUNNER PLATES LIMA, S-- z • L • • • '• ,, � LAV Ex -WC • '" �� '� DF USE OR PLATE 9' GAI..VANIZED VANES FOR GALVANIZED ALUMINUM DUCTS - :TAME GAUGE AS DUCT 4 I/2 � 0� �� � �G Li LAV ft ' ! 1 H DF ATTACH DAMPER TO r j MOUNT SLEEVE IN BLDG. CONSTRUCTION- SLEEVE TO 15E OF GAUGE AS REC. 1:3Y � I r SLEEVE AS REQUIRED 5Y MANUFACTURER MANUFACTURER FOR U.L. APPROVAL- Ii AIR FLOW -SMOKE DUCT - \ RESETTAELE FIRE -SLAT (MGT) SENSOR �__ � � --� W NOTES: PLUMBING SHALL NOT BE INSTALLED IN THE CONNECTION TO EXISTING UTILITIES MUST BE DEMISING WALLS OF THE LEASE SPACE. COORDINATED AND SCHEDULED IN ADVANCE WITH THE MALL OPERATIONS ALL WATER PIPING HALL BE COPPER 'PVC' MANAGER PIPING NOT ALLOWED AS PER LANDLORD CRITERIA- ALL VENT PIPING SHALL BE CAST IRON OR GALVANIZED STEEL 'PVC' PIPING NOT ALL SANITARY PIPING SHALL BE CAST IRON ALLOWED AS PER LANDLORD CRITERIA. PVC PIPING NOT ALLOWED AS PER LANDLORD CRITERIA. ALL PIPING SYSTEMEi SHALL BE PRESSURE TESTED IN ACCORDANCE WITH LANDLORD CRITERIA- _._\ t -- h ��- 31/4 " 11/2 \ \I 0o R= dm l N W [J C_ I__I__I \ I -L � I UCT 51 O 36'X ' D ZE VER 3 DUCT SfZE 36 X36 OR UNDER SQ, ELBOW WITH TYPE 'A' SQ. ELBOW WITH SINGLE DOUBLE THICKNESS VANES THICKNESS VANES TYPICAL CONNECTION STEEL BLADES — A BOLT TO SLEEVE (TYP.) RETAINING ANGLE. SIZE AS RECOMENDED BY DRAFT STOP ■ I F CONSTRUCTION MANUFACTURER (TYP.) CD „-t- ` V d I I--- 0 COMBINATION FIRE/ SMOKE AMPS IR SCI--IEMAT IC ''. WATER 'I SEIR (NTS) r PLUMS NG FLAN 5 TURNING VANE SC if MATIC STORE NO. Champs: v i I° 0 ALL WATER LINES, VENT LINES, DRAIN LINES, SPRINKLER LINES, ETC. SHALL BE OFFSET BELOW PLATFORM AND CONCEALED IN WALL ABOVE PLATFORM. DO NOT ROUTE PIPING, ETC. THROUGH STORAGE SPACE AEOVE PLATFORM OR ABOVE ELECTRICAL EQUIPMENT. CONNECT NEW SANITARY LINE INTO THE TENANT'S EXISTING SANITARY SERVICE. FIELD VERIFIES EXACT LOCATION. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. ® EXTEND NEW VENT THROUGH ROOF. REFER TO STACK DIAGRAM AND PLUM1 =SING SPECIFICATIONS FOR FURTHER INFORMATION. Q CONNECT NEW WATER LINE INTO THE EXISTING WATER LINES. VERIFY EXACT LOCATION OF EXISTING TENANT LINES. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. ® FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HoT WATER PIPING AS SHOWN aN THE WATER RISER DIAGRAM. WATER HAMMER ARRESTORS TO EE LOCATED IN AN ACCESSIBLE LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE AGCEPTA£3LE- O ALL PLUMBING FIXTURES SHALL 5E INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. � NOTES: 1. SYMBOL KEY- 4. VOLUME DAMPER - FIRST LETTER: 5- SUPPLY R- RETURN E -EXH FACTORY FURNISHED. OPPOSED BLADE OR T- TRANSFER BUTTERFLY WHERE AVAILABLE. ADJUSTABLE SECOND LETTER: D- DIFFUSER R- REGISTER FROM FACE. G- GRILLE 5. BORDER STYLE - 2. PROVIDE OPTIONAL DIRECTIONAL BLOW 'A' SURFACE MOUNTED FEATURE FOR OTHER TI-IAN 4 -WAY. 'B" LAY -IN, PROVIDE WITH PLASTER FRAME FOR DRYWALL CEILING MOUNTING. 3. FINISH- 'C' LAY -IN FRAME FOR T -BAR CEILING. 'A' WHITE. 'i5' WHITE - G.C. TO FIELD PAINT TO MATCH 6. PROVIDE Baal FOR DUCT MOUNTING. CEILING OR WALL WITH ENAMEL FINISH. SYMBOL (1X21)_I MANUFACTURER/ CATALOG NUMBER NOMINAL SIZE i~IOUNTING MATERIAL FINISH «� I:7 (4) BORDER «� REMARKS MOD. NECK CEIL- 1MG OTHER STEEL ALUM. +,� � ` j < > - r qi 4 °c° r.., t �,� 3 r; ;'v r `''a ��+ r � T y w b i 4i d , ° s r gg a �� T91d4 �d1S.i 'Y k y tP.: ke ''`s,, SD - I TITUS TM ' 12 6' O A 0 A SG - TITUS 300RL 10'x10' 8'x8' DUCT # A O A DUCT MOUNTED TG -I TITUS 355 38'x18' 36'x16' DUCT S A A DUCT MOUNTED, RHG -1 TITUS I 355R.1_ 48 x24 r " 42 xl8 0 A A PLUMB ING CODED NOTES NOT USED AIR DEVICE CIE: (NTS) REV ISIONS SE PARATE p ll nf .�. t EX -WC WATER CLOSET - EXISTING TO REMAIN. L.AV LAVATORY - AMERICAN STANDARD 'COMRADE' MODEL *0124.024 WITH NO. DESCRIPTION DATE 1 L.L. COMMENTS /OWNER 12r03/0a CHANGES AERICAN STANDARD FAUCET 'RELIANT' MODEL *2385.000 WITH POLISHED CI -IROME FINISH- EQUALS 5Y KOHLER OR CRANE. EX-W1-1 WATER HEATER - EXISTING TO REMAIN. FGa FLOOR CLEAN OUT - ZURN MODEL *Z -1400 'LEVEL TROL' ADJUSTABLE, 2 L.L./1005 COMMENTS 12/1 - 1/08 4 OWNER CHANGES FAN I C O UNIT I L UNIT SCHEDULE QUANTITY UNIT NUMBER YORK MODEL * SNO1 WON SUPPLY FAN 1/OLTA!'.E/ PHASE: ELECTRIC HEAT TOTAL CLG. BENS. CLCs. MAXIMUM FUSE SIZE O.A. CFM NOTES � � `' EXIST. BAR JOISTS (TYP DURA- COATED CAST -IRON EDDY, WITH GAS WATERTIGHT AB5 TAPERED THREADED PLUG, AND ROUND SCORIATED SECURED TOP ADJUSTABLE TO FINISHED FLOOR. EQUALS E3Y J.R. SMITH OR WADE WHA WATER HAMMER ARRESTER - SIOUX CHEIF 150 SERIES OR EQUAL En REVISION RF��I t) r OR ; HP O z u SP RPM KW STEPS No changes shall be made to the scope approval o f e chaficat of work without prior app , Tukwila Building Division. nElectrical NOTE: Revisions will require a new lan submittal g and may include additional plan review fees. 0 Plu mbing Gas Piping l Cit of Tukwila i _- Blv.,l `i,bL DIVISION C�' �" f Pc rnii% No. I I o .. .. I _. • ^ Y .. fir q n fi ,t " ft� Crt� . L': =1 C -' -j --. �.' ,ma . .. r: -- rrvi'�J cprro1 II 1 l �� ._.-, ,.- ;~ - . - .._ � - .! � • C.'3G�:�:�'i�::� �y .. � t :w i ti � >, . � - = � � �� }' � 1� ? fi r �, - . . CI c.;t 'rt.. ... >, - . :t r Jr .[ �- . � �.- . �. r Y.. rt yG� 5.f L,9! �� tL: .�s.. C 11t +C1 G:, i,. .�; G' ' � � � ^. JAN 0 9 ��1� t' �� \,'� . +t� ; Gf � .;I;,J �.:�.��.t... . � � +3y' p;;rG - -4 44 -4 44 + [ B • , - 2 � c a D Date: °` `i C t @, ? s3D w1 r .,,� �,., L L J1 ;3, DiVi •L 3 I AHU -I FIEH150 IS 3 6100 1.0 803 � 20e-3 22.5 2 113 129 - - 1305 0 PRECISION PLUMBING PRODUCTS, INC. MI5 MOP BASIN - FIAT *MS5-2424 MOLDED STONE MoP BASIN WITH VINYL BUMPERGUARD. FURNISH WITH AMERICAN STANDARD *9344-111 FAUCET WITH INTEGRAL VACUUM BREAKER AND STOPS. EQUALS BY STERN- WILLIAI °iS OR MUSTEE_ F DRINKING FOUNTAIN - OASIS WHEELCHAIR MODEL *PACSL, WALL MOUNTED. FURNISH WALL HANGER PLATE, CHROME P -CRAP AND SUPPLY ST OP. MOUNT ?a "ANSI" STANDARD FOR HANDICAPPED AT 34 1/2' MAX. FR FLOOR TO SPOUT OUTLET. ® _ - - SHE ET NUMBER MECHANICAL DETAILS AND SCHEDULES I� DEC 3 0 2000 M2 ■ PERMIT CENTEF • NOTES: I. Unit to be provided with field Installed sprinc,� Isolator _ .. 5/V0 A36 ROD, DOUBLE NUT AT C. WELD NUTS TO ROD AFTER UNIT IS SET. (TYP) AHU - -- - N a E N -__- -- - - - - _ I N G UNIT E -� E C U LE — A I LE - QUANTITY - -_- - UNIT NUMBER -- _ YORK MODEL _ _ _ SNOT WON COMPRESSOR CONDENSER FANS EZIS asn WnwixVW OA. TEMP NOTES REF TYPE u CAPACITY STEPS STEP vOLT E/ PH ASE N ©. HP EACH CAP. MES 1 A - 1 E 1 F D 1 80 15 R - 22 1 113 ._ 2 @8••3 2 I _ 113 SS Q �� C DOUBLE NUT AND SPRING ISOLATOR AT AHU'S AHU AHU MAX.) _ L3 x 3 x 3/16 AT 1/1 SLOPE FROM TOP OF SUSPENSION BRACKET T BO TTOM OF JOIST USING 3/16 FILLET WELD ALL AROUND. (TYP.) SUPPORT HANGER SHALL EE SPACED MANUFACTURER'S RECOMMENDATIONS SUSPENSION BRACKET. WELD NUTS TO ROD AFTER UNIT IS SET. (TYP.) PER (4' -0' NOTE: 1 PROVIDE WITH FIELD INSTALLED LOW AMBIENT CONTROLLER FOR 0 DEGREE OPTERATION 2. PROVIDE PROGRAMMABLE NIGHT SETBACK THERMOSTAT. INCOMPLETE 3. INSTALLING CONTRACTOR SHALL PROVIDE ALL LOW VOLTAGE WIRING. , T R #_..... 4. 2 83 A1-1U SUPPORT '.T SCE -IEMAT IC - SEISMIC FLUM5ING FIXTURE SCHE 1 UL I -IVAC UNIT SCHEDULE