Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG08-287 - ANALYTICAL RESOURCES
ANALYTICAL RESOURCES 4611 S 134 PL PGO8 -287 Parcel No.: 2613200042 Address: Suite No: Citc:if Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 4611 S 134 PL TUKW PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: PG08 -287 12/15/2008 06/13/2009 Tenant: Name: ANALYTICAL RESOURCES Address: 4611 S 134 PL, STE 100 , TUKWILA WA Owner: Name: ARION PARTNERS LLC Address: 4611 S 134TH PL STE 100 , TUKWILA WA Contact Person: Name: JUNIUS W HARVEY Address: 835 NORTH CENTRAL AV, STE 132 , KENT WA Contractor: Name: ACCO ENGINEERED SYSTEMS INC Address: 6265 SAN FERNANDO RD , GLENDALE CA Contractor License No: ACCOESI971DU Phone: Phone: 253 854 -8444 X 131 Phone: (818)244 -6571 Expiration Date: 10/13/2009 DESCRIPTION OF WORK: CONNECT EXISTING GAS PIPING TO UNIT Value of Plumbing /Gas Piping: $200.00 Fees Collected: $92.00 International Fuel Gas Code Edition: Uniform Plumbing Code Edition: 2006 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet FIXTURE TYPE AND OUANTITY 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 1 0 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -10/06 PG08 -287 Printed: 12 -15 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PGO8 -287 Issue Date: 12/15/2008 Permit Expires On: 06/13/2009 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied nu 'th, Date: 12'1 A d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction 4r the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Signature: Ll)/4 Date/ -- Print Name: U(11 tai LAS' /16r -G� y This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -287 Printed: 12 -15 -2008 Parcel No.: 2613200042 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 4611 S 134 PL TUKW ANALYTICAL RESOURCES PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG08 -287 ISSUED 12/03/2008 12/15/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -287 Printed: 12 -15 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name : 4 1.4 /1.1"" (A ti; Date: �� — 7507 ordinances governing or local laws regulating doc: Cond -10/06 PG08 -287 Printed: 12 -15 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us No. Mec apical Permit No. ,011 ' Plumbing/ Permit No. ('�` Pub lie Works Permit No. Project No. Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 2613200042 Site Address: 4611 S. 134TH PLACE, SUITE 100 Tenant Name: ANALTICAL RESOURCES Property Owners Name: ARION PARTNERS LLC Mailing Address: 4611 S. 134TH PLACE. SUITE 100 Suite Number: 100 Floor: New Tenant: ❑ Yes [t..No Tukwila City WA State 98168 Zip • CONTACT PERSON wbo di Name: Junius W Harvey Mailing Address: 835 north central ave suite 132 E -Mail Address: jharvey @accoes.com Day Telephone: 253 - 854 -8444 x131 Kent WA. 98032 City State Zip Fax Number:253- 854 -8220 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: ACCO ENGINEERED SYSTEMS Mailing Address: 835 north central ave suite 132 Contact Person: E -Mail Address: Michael Walker mwalkert accoes.com Contractor Registration Number: AC CES1971DU Kent WA. City State Day Telephone: 253 -854 -8444 Fax Number: 253 -854 -8220 Expiration Date: 10/8/09 98032 Zip ARCHITECT OF RECORD - All Mans must be et stamped by Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: State Zip ENGTl OF I +CORD - Ail plans must be wet stamped by Engine Company Name: Mailing Address: Contact Person: ACCO ENGINEERED SYSTEMS 835 NORTH CENTRAL AVE Chris English E -Mail Address: cenglish @accoes.com KENT WA. City State Day Telephone: 253 - 854 -8444 Fax Number: 253- 854 -8220 98032 Zip MECHANICAL PE ` T INFORMATION - 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: ACCO ENGINEERED SYSTEMS Mailing Address: R35 NORTH CFNTRAI AVF SUITF 132 Contact Person: Michael Walker E -Mail Address: mwalkPraRrrnps rnm Contractor Registration Number: Acr'.nFGIgll Du KFNT City WA State PRn32 Zip Day Telephone: 253 - 854 -8444 x145 Fax Number: 253- R54 -R22n Expiration Date: 10/09 Valuation of Mechanical work (contractor's bid price): $ 60,000 Scope of Work (please provide detailed information): Installing of one rooftop MAU Use: Residential: Commercial: New .... ❑ Replacement .... ❑ New .... © Replacement .... ❑ Fuel Type: Electric ❑ Gas....© Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Comm/Ind n:s-- r...:.....:c,...... w-- r-- .:., -. n.. w-- r_.,.:.._'__ PLUMBING AND GAS PIPING P'EpiMIT INf'4RMATION - -x06=431 -367 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: ACCCO ENGINEERED SYSTEMS Mailing Address: 831 NORTH CENTRAL AVE SUIT 132 Kent Contact Person: Michael Walker E -Mail Address: mwalker @accoes.com Contractor Registration Number: accoesi971 du City Day Telephone: Fax Number: Expiration Date: WA. State 253 - 854 -8444 98032 Zip 253 -854 -8220 10/09 Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ 200.00 Scope of Work (please provide detailed information): connect existing gas piping to unit Building Use (per Intl Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets 1 Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PERMIT APPLICATION NOTE — Applicablc to ll perrtllits in tlilis application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Nam Date: %g : , 2 — O kC' Day Telephone:Ar5 - ,�S' /� cp'l /7 city L4 5 j State Mailing Address: F '$ /j 1i �1 ( .-1 / Date Application Accepted: �� Date Application Expires: RI 9 VLC J Staff Initials: 46.-A.A., (1• \Annlirainn, Vnnn._Annli..Ann. fl,. T inata_1n06 _ P.....:. Ans..r..., a.... City of Tukwila, Department of Community Developm en t 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: httn: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -03856 Initials: JEM User ID: 1165 Payee: ACCO ENGINEERED SYSTEMS Payment Date: 12/03/2008 Total Payment: 918.25 SET ID: S000001144 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount M08 -278 826.25 PG08 -287 92.00 TOTAL: 826.25 TRANSACTION LIST: Type Method Description Amount Payment Check 006702 918.25 TOTAL: 918.25 ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.103.00.0 92.00 000.322.102.00.0 661.00 000/345.830 165.25 TOTAL: 918.25 0130 12/03 9707 TOTAL 918.25 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 NSPECTION RECORD Retain a copy with permit rgOe-287 PERMIT NO. (206)431 -3670 Project: A/41 q—r 4l 42z ; ear Type of Inspection: /E'er ,i1�► f -- 695. Address: '/ // S /J 'f .0(..._ Date Called: Special Instructions: 9 / Date W nted:- Requester: 44/e , /(/7 / l Phone No: f Approved per applicable codes. Corrections required prior to approval. C MMENTS: h- 4) P., tot fV(10-147, Date: $ .00 REINSPECTION FEE REQ E . Prior to inspection, fee must be • = id at 6300 Southcenter Blvd., Sui 00. Cast to schedule reinspection. ipt No.: 'Date: Untitled Page Page 1 of 3 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company ACCO ENGINEERED SYSTEMS INC 8182446571 6265 SAN FERNANDO RD GLENDALE CA 91201 OUT OF STATE CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601003669 ACTIVE ACCOESI971 DU CONSTRUCTION CONTRACTOR 3/31/2003 10/13/2009 AIRCOCI131 KQ GENERAL UNUSED Business Owner Information Name Role Effective Date Expiration Date AVESANO, JOHN P PRESIDENT 03/31/2003 Bond Amount KESSLER, ROBERTA R SECRETARY 03/31/2003 08030409 BROWN, ROBERT A TREASURER 03/31 /2003 KRASSENSKY, RONALD VICE PRESIDENT 01/22/2004 HAMMOND, ROBERT T VICE PRESIDENT 01/22/2004 MARRS, JEFFREY R VICE PRESIDENT 01/22/2004 NARBONNE, PETER H VICE PRESIDENT 01/22/2004 RICHTER, CHARLES K VICE PRESIDENT 01/22/2004 WESTPHAL, KENNETH B VICE PRESIDENT 01/22/2004 YATES, RICHARD D VICE PRESIDENT 01/22/2004 GOODMAN, MILTON L VICE PRESIDENT 01/22/2004 SMITH, STEVEN J VICE PRESIDENT 01/22/2004 VLICK, ROBERT P VICE PRESIDENT 03/31/2003 LUDOLPH, DOUGLAS E VICE PRESIDENT 11/06/2006 BOYSEN, THOMAS C SECRETARY 01/22/2004 11/06/2006 MCNAMARA, WILLIAM B VICE PRESIDENT 03/31/2003 09/01/2004 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 FIDELITY & DEPOSIT 08030409 10/01/2001 Until Cancelled $12,000.00 10/02/2001 https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= ACCOESI971 DU 12/15/2008