Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG08-249 - MCDONALD'S
MCDONALD'S 15210 TUKWILA INTERNATIONAL BL PGO8-249 Parcel No.: Address: Suite No: Cityillf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PLUMBING /GAS PIPING PERMIT 0043000090 15210 TUKWILA INTERNATIONAL BL TUKW Permit Number: Issue Date: Permit Expires On: PG08 -249 09/19/2008 03/18/2009 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: MCDONALD'S RESTAURANT 15210 TUKWILA INTERNATIONAL BL , TUKWILA WA COMISKEY ROBERT C/O MCDONALD'S , 245 SW 193RD PL RON FAWCETT 8823 CANYON RD E , PUYALLUP WA Contractor: Name: FAWCETT PLUMBING INC Address: 8823 CANYON RD E , PUYALLUP WA Contractor License No: FAWCEPI023LW Phone: Phone: 253 606 0857 Phone: 253 - 531 -6000 Expiration Date: 05/27/2009 DESCRIPTION OF WORK: PLUMBING WASTE AND VENT FIXTURES, GAS PIPING, AND WATER PIPING FOR NEW RESTAURANT Value of Plumbing /Gas Piping: Fees Collected: $64,000.00 $764.25 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 7 1 Water heater and /or vent 1 0 Industrial waste treatment interceptor, including 1 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 14 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 3 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 4 Medical gas piping (6 +) inlets /outlets 0 5 Gas Piping 1 Gas piping outlets (0 -5) 1 0 Gas piping outlets (6 +) 2 * *continued on next page ** doc: UPC -10/06 PG08 -249 Printed: 09 -19 -2008 City of/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG08 -249 Issue Date: 09/19/2008 Permit Expires On: 03/18/2009 Permit Center Authorized Signature: Date: q`' L (/ V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this 'emit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or - erform ce 95'work. I am authorized to sign and obtain this plumbing /gas piping permit. q� ?� Date: _/ `-0" Signature: Print Name: N ) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -10/06 PG08 -249 Printed: 09 -19 -2008 Parcel No.: 0043000090 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 15210 TUKWILA INTERNATIONAL BL TUKW MCDONALD'S RESTAURANT Permit Number: Status: Applied Date: Issue Date: PG08 -249 ISSUED 09/11/2008 09/19/2008 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted m the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG08 -249 Printed: 09 -19 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. .410 q Q� Signature: s • Date: / Print Name: ' �i 4 F74 Ze7C.?f i ordinances governing or local laws regulating doc: Cond -10/06 PG08 -249 Printed: 09 -19 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwild.wa.us Applications and plans must be complete in order to be accepted for plan review: Applications will not be accepted through the mail or by fax. * *Please Print ** v King Co Assessor's Tax No.: D Site Address: 15 . \O -- Tenant Name: V\ c- %CINATei� --�� Property Owners Name: V\ eitio %∎0As \ - `-\^C- __ Mailing Address: \a \3\ \ \3':Ile, 'R\V -, b3 YzIN\M-914 _ >a V Suite Number: - 1200 --00610 Floor: New Tenant: ❑ - - Yes ❑ ..No City State Zip ACTS wl o do we contactt"whee4 y r permit;is • ready .to c issued Name: Ik'N0 WC--N-N _ Mailing Address: 'i?'a a3 - Day Telephone:a53- Qa0Co— Q$ 5j'1 Q MP, 1-143.9 B'1\ E -Mail Address: City State Zip Fax Number :;L53 -5 31-Co OD ,��^GEERAL CONTRACT'UR INFORIVIATION s .iv t^ �&i+ ` `'°'ti,�P?fi 9°Rt tl�a:�r " �o' '.i '4*1( -•9�'' '""' , i ,.���- .... , ,(ContractorPTnformation for gechamcal (pg 4) for ont log;and Gas Piping (pg 5)). Company Name: 41 -'E ST Q 1- V.%�1�1G- _ Mailing Address "$13_ C-1C\ 'N`‘'\01A Vo 'E._ Qv.��l-r -l1,Q_ - \N t, - A31 City State Zip Contact Person: %1J - _ A $ - 'S Day Telephone: '15 - 5'3\ ` C0 0 0 E -Mail Address:\ -O\ 5v- c'R\+JC\X Q\.,V.hIitSNJ(7,con Fax Number: �j 3- 5 31- Coto Contractor Registration Number: V\ W CAI? (Y) L\„) Expiration Date: a \ - aooek All plans must be wettstampea by Architect9of Recor.' Company Name: — Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip I plans must be e( stamped by ]Engineer - :of Record Company Name' Mailing Address: City State Zip Contact Person: _— _ Day Telephone :_ E Mail Address: _ Fak Number: Q:\Applicaiions\Fo,ms- Applications on t.ine3'- -2006 = Permit Application.doc Revised: 9 -2006 bh Page 1 of 6 ten, g'Ut M _ fu 206I STES47� PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: C."'S"' Q\ —V06.1ti (r" Mailing Address: %'% Tc'Q S'i Contact Person: ilk\O`‘ ' r A 4Z C- VV.% \\-- 001 y e.va E -Mail Address `C\'zE % f'Fi - Qh uX•cisi-N1 t'- •to Contractor Registration Number: VA C @ 0 rati.41 es-AC—. %Akkvl\ -`1).* \61t% tip3''�1 City State Zip Day Telephone: 253 -5'6 1' Ce 00M Fax Number: g.51— �J 3\ Coon \ Expiration Date: 0s a" 1-a00k Valuation of Plumbing work (contractor's bid price): $ t 3 0) O 00 Valuation of Gas Piping work (contractor's bid price): $ 'yDa 0 Scope of Work (please provide detailed information): P4UM.h,y9 W.43i,(?'_ rot st2, ie0s G 4s Pip.A/ 9 £c/4Y-eR 1:1;i0 Building Use (per Int'l Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: FiztiireTypes `,,7. -. " Q"ty ;rFaiii iiM `: ; ::Y'` " ": Qty Fixture Type : ,Qty` `Fixtiu`re Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets 7 Bidet Food -waste grinder, commercial Receptor, indirect waste 61 Clothes washer, domestic / Floor drain s1-/ Sinks Dental unit, cuspidor Shower, single head trap Urinals / Dishwasher, domestic, with independent drain % Lavatory 3 Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) �j ! Water heater and/or vent ` Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Q:\Applicationsworms- Applications On Line \; -2006 - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 >Iermlts ><n ls;appllcato Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER �AUT AUTHORIZED AGENT: Signature: &et- _ t7 Y Print Name: Re 4 F,44 W C F7t Mailing Address: 8 8 a3 CA M yn N P Day Telephone: P4y& 4Lu/d City Date: `7--/(' State Zip Date Application Accepted: 01 1 u 1'A Date Application Expires: as/ f t I0 A 4 ` 1 Staff Initials: %� /r 1 Q:Wpplicalions\Fonns- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 0043000090 Permit Number: PG08 -249 Address: 15210 TUICWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 09/11/2008 Applicant: MCDONALD'S RESTAURANT Issue Date: Receipt No.: R08 -03297 Payment Amount: $630.60 Initials: WER Payment Date: 09/19/2008 10:23 AM User ID: 1655 Balance: $0.00 Payee: FAWCETT PLUMBING TRANSACTION LIST: Type Method Descriptio Amount Payment Check 23458 630.60 ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES PLUMBING - NONRES 000.322.103.00.0 106.60 000.322.103.00.0 524.00 Total: $630.60 ` :9!19 TO TA_ A_ ,.: `O .& doc: Receiot -06 Printed: 09 -19 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0043000090 Permit Number: PG08 -249 Address: 15210 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 09/11/2008 Applicant: MCDONALD'S RESTAURANT Issue Date: Receipt No.: R08 -03225 Payment Amount: $133.65 Initials: JEM Payment Date: 09/11/2008 10:29 AM User ID: 1165 Balance: $630.60 Payee: FAWCETT PLUMBING, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 23422 133.65 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 133.65 Total: $133.65 7:21 39/1.. � 70? TOTAL 1=:3 doc: Receiot -06 Printed: 09 -11 -2008 INSPECTION NO. INSPECTION RECORD Retain a copy with permit Pag-zet9 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: k DO/U4/,Z).. Type of Inspection: ,/ iti rq /— /)( / 6 Address: /52/6 i�6 Date Called: Special Instructions: / Date Wanted: a.mm.. Requester: Phone No: .'5� -377 :gel /c Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: [N1 1 Cci 1 / Per. d A) )44 A (--)l Inspect9r: --� Dater ? 4) $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of In pectin l Ai CD- .05-k - 'frke,SA Address: Date Called: NO i /bt r,e t.:- -, / 152(O I .-1-,3 Special Instructions: Date Wanted: 7 - Z -4) �/ 6 t a.m. P.m. Requester Phone o:s 3 ? I 24 Approved per applicable codes. Corrections required prior to approval. COMMENTS: CD- .05-k - 'frke,SA t .01TO e___ A NO i /bt r,e t.:- -, S LIO Cc c. (9 -, 4::: ill" j Inspector O Date: $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: .en .. -- . �...,..,_- 1:t_3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. . PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: me Dowvii os (mss Type of Inspection: i (LA (- P dl,c r II l':11.( . 3:n -- 1{. -1vi. Ott ( &e I &`tefi)r I Luirc�-1;a1 1.0p,ei f--13A-t. Address: � 15210 --� 1 - - P Date Called: 1 e_11 Cf JA 101,-)0 1 a iJJ f(t, r Special Instructions: Date Wanted:. 2- \d_Q9 \ cckek rk (k' Vii i � CA-5 : CAT CA-5 )--1 ZD A - - p' Requester: ,P Phone No: 7--' 3- 3"7-2-14 / S 0 Approved per applicable codes. Corrections required prior to approval. ,% COMMENTS: / I !t-) (j- I S ' I( J (.) L. Q-J ?1 % r_ A. -+`)1 r II l':11.( . 3:n -- 1{. -1vi. Ott ( &e I &`tefi)r I Luirc�-1;a1 1.0p,ei f--13A-t. (2.) ((fr ) S V /.k , /t 0/ re-"'-' / J 3)C 1 e_11 Cf JA 101,-)0 1 a iJJ f(t, . )(k (D ,(u c:rar �-A (M1 (-b \ cckek rk (k' Vii i � CA-5 : CAT CA-5 )--1 ZD A - O ,ArP .)( -- , JP( u-k4JP twn, ,P Inspettotor: Q J'(M n$60.00 REINSPECTION FEE EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 2 y Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISI ON 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit P6, Ds-24 PERMIT NO. (206)431 -36; Projegti Type of Ins ection: i Mc �',� A"( A S r1,", i-'t b c'.1 ivy Address: 1cr2.v rr3 Date Called: f --.... Special Instructions: zi Date Wanted: a.m. Pam Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: T SC-". ti 6u el OA aas -rf .c-t-- A 4 Jr) 0 A Lyper .S���t� u Inspector: Date: r D 6 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 41-4 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Project: I ADef/b42y) Type Inspection: r6' GGJ o.rs (i) (7 Address. ,Ps i i Date Called: 1 /-- -2 /v /' Z J3 Special Instructions: _...--°-- Date Wanted: ��� a;m. Requester: .r Phone No: _-Z 3. 377-20 .-- Approved per applicable codes. D Corrections required prior to approval. COMMENTS: r 0 ' ,14..A- _ (O o.rs (i) (7 ,p)c e 6'0 pS % ,Ps i i 1 Inspec $ Date:I / J Os- ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: � PERMIT COORD COP* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: PG08 -249 DATE: 09 -11 -08 PROJECT NAME: MCDONALD'S RESTAURANT SITE ADDRESS: 15210 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: nr 'vision 1e6 Public Woilis Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 09-16-08 Not Applicable Ti Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Notation: Approved with Conditions DUE DATE: 10-14-08 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Untitled Page 0 • General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company FAWCETT PLUMBING INC 2535316000 8823 CANYON ROAD E PUYALLUP WA 98371 PIERCE CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601878428 ACTIVE FAWCEPI023LW CONSTRUCTION CONTRACTOR 6/16/1998 5/27/2009 FAWCEP *026BJ GENERAL UNUSED Business Owner Information Name Role Effective Date Expiration Date LINDSAY, KEITH PRESIDENT 01/01/2006 Bond Amount FAWCETT, PATRICIA A PRESIDENT 01/01/1980 01/01/2006 FAWCETT, RONALD D Until Cancelled 01/01/1980 01/01/1980 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 CBIC SE9747 05/27/2003 Until Cancelled $12,000.0005/02 /2003 3 TRAVELERS CAS Et SURETY CO 206881342 04/01/2002 Until Cancelled 05/27/2003 $12,000.00 04/03/2002 2 TRAVELERS CAS a SURETY CO 206881342 05/27/2001 04/01/2002 $6,000.00 03/09/2001 1 UNITED PACIFIC INS CO 6881342 05/27/1998 Until Cancelled 05/27/2001 $6,000.00 Insurance Information Page 1 of 2 https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= FAWCEPI023LW 09/19/2008 rr - Ito 9!diig C F.; requiro a le 'N Fi!hr: - nay rde ac.!ciii( na ran '!((s SCALE /4"= • . . . I ','.•••:::i] . . . • I C'C',.: ... 1. ... CO 4 44 nxtic 1. :SEE DRAWING P3.2 FOR PLUMBING LEGEND. 2. :SEE DRAWING PO.0 roti GENERAL PLUMBING NOTES. 3. :SEE DUWING P3.2 FOR PLUMBING FIXTURE SCHEDULES A DETAILS. 4. :SEE DRAWING P2.0 FOR PLUMBING ROUGH-INS. 4IP - • • , ^ • 1' • - - • - . • • • ...... • rr If I 1 , ,•••••ti I •i:': ..1 I .•''' — - I r • • ` "" • --• HB- I Tr t ' • : D HYDRANT ON ROOF • t I S- I 1 1 1 I L I LAV- r L_ • , — cgco •. • 1 I 1 I I I I 11 1 INCOMING UNDERGROUND WATER SERVICE (SEE SITE PLAN FOR CONTINUATION) CW UNDERGROUND TO Y D HYDRANT (HB-3) IN TRASH CORRAL (SEE SITE PLAN FOR CONTINUATION) PROVIDE ACC E FOR ALL VALVES (TYP.) 3r_SS RPZ i Ij TO TATER -C N CHECK VALVE r COARSE FILTER PC BSI LED CONDENSER PRESSURE GUAGE LI LOW PRESSURE SWITCH HIGH PRESSURE SWITCH 1(51 FULL-PORT BALL VALVE OD PUMP tJ SOLENOID VALVE 1 1 1 1 L _J BYPASS --- --+WR 1 1 0°F sc:=41:1:• I L [-- • . ' " ' ...:„- SYM OL LEGEND THREE-V/AY ViVE L>&I PRESSURE REGULATOR INN] DUAL CHECK VALVE i _ i ;t 1 DUAL CHECK VALVE WITH VENT H STRAINER RE'LlEF VALVE 1 F I I 11 11 11 11 11 11 u__ CONSTANT WATER PRESSURE MODULE 4 BOOSTER TAM BEVE ,i7.77.77.:.••======== r \ NOT T* SCALE STER J COOLING COIL AGE S STEP FINE FILTER ACCUMULATOR TANK "-WASS -j 35 PSI )(5 ORANGE JUICE (TWICAL) num WATER CLEAN-IN-PLACE PANEL LI • 1 (5, PHOSPHATE FEEDER 61- H KB REGULATOR PRE-FILTER PERMEATE PUMP COOLING COIL SODA TOWER (TYPICAL) DISPENSER (TYPICAL) DISTRIBUT ON SCHEMAT CO2 ••,-, re", e7 , 6E6-ACUTE PLAMif 1 HEQUiRED FdR: 1 pi COityGoafsTPuipkiwngm PI,i,I).011 ':' , . - :101\fiSICIN 441 echanicei 6 v , E i l u e rr c , , b ri i c ri a g i 2.5 GAL. STORAGE TANK P,EVERSE OSMOSIS FILTER CALCITE FEEDER 1 H k r1 4-TREATED WATER TO ICED TEA BREWERS --TREATED WATER TO ICE MACHINES %O. WATER „ TO BUN im STEAMER FELE con Permit No. _J L [ D pi review epprovaI is subject to errors and omlssions. Appron! of construction documents does not authorize thc violation of any adopted code or ordinance. Receipt of approved Copy pid contftjons is acknowledged: By 1.41e/-c Datc, City of Tukwila BUILDING DIVISION / Of Tu ila RUILDINaDIVISIO /-20 GAL STORAGE `ANK CYST REDUCTION MILTER R.O. MIER -TO ESPRESSO AND COFFEE RECEIVED CITY OF TUKVVILA SEP 1 1 2008 PERMIT CENTER 7z.) (V.) TX7M a 0 1 11.. 0 o u o C :3 - 0 a v, 2 -0'6 2.3_ 0_0_0 0.J 0, 0 L o E 1. <17.3 0 0 6 C c -..- -:, 0 .-- 0 0 00 S0 _C E •-;•L 0 0 oi 0 Q..) - EL ... 0 C C ;, ., ' , c - 0 0 - 7•, E : Q' CJ v 0 0 0 0 )=. CU _M 0 73 c t 0 fa E r ;t2 0 r_• 0 0 < . cn u 0 n i- 0 C.: - 0 -C ' 0, 0 Cl) Ul 0 0 0 0 Cc) C/1 cyt C 6 a L. 0 (1.) Q VI 0_ 1- a it.' LT) - c..) t 0 0 (1) L U (1.1 V oJ 0 r- 0 0 g : 3 j - 0 o v 0 0 0 812 0 c L 0. ( o ) 0 0 2 - rD c - 0 D c n V 0 cn o .0 61 _c 0_0 Cr) 0005 „ 00 0 Pgn C egj 0 !)1ATE-Z Pi n% 4) • I L 1 /4 = - il - ' SEE DK, WING P-a3.2 van PLUMBING LEGEND. 2 SEE DRAWING P -0.0 F06 GENERAL PLUMBING NOTES. 3. SEE DRAWING P-3a2 FUR PLUMBING FIXTURE SCHEDULES AND DETAILS. 40 SEE DRAWING P °2.0 FOR PLUMING ROUGH—INS. PR AN N N 7'5 II II II I I II ri SANITARY UNE TO SANITARY SEWER (SEE SETS PLAN FOR CONTINUATION) GREASE LINE TO EXTERIOR GREASE INTERCEPTOR (SEE SITE PLAN FOR CONTINUATION) STORM LANE TO STORM SYSTEM (SEE SITE PLAN FOR CONTINUATION) TERMINATE OVERFLOW DRAIN AS HIGH AS POSSIBLE WITH DOWNSPOUT COVER TERMINATE OVERFLOW DRAIN A VE TRELLIS WITH DOWNS "3 UT COVER TERMINATE OVERFLOW DRAIN I2 A , VE FINISHED FLOOR WITH EtOWNSPOI T COVER r VENT THROUGH SIDE WALL -- TERMINATE WITH RIRDSCREEN c P� PLUMBING CONTRACTOR SHALL COORDINATE FLOOR DRAIN LOCATIONS WITH P cDONALD ° S AREA CONSTRUCTION MANAGER AND SWAM, VERIFY THAT FLOOR DRAIN LOCATIONS MEET LOCAL CODE REQUIREMENTS (DISTANCE FROM TRAP TO VENT) PLUMBING CONTRACTOR SMALL ROUTE PLAYPLACE VENT PIPE SUCH THAT IT AVOIDS THE UPPER LEVEL GLASS 1)G68- V17 REVIEWED I OR. \ ta__ CODE COMPLIANCE AP EVE SEP 1 8 2000 CIS Tukwila RECEIVED CITY OF TUKWILA SEP 1 1 2008 PERMIT CENTER it i � I , I � I I , NV? I - I . 1 ..\ /7/1 C41 ' 2. , H - ; ,, g ,___ . - , -------, . .,,.... . . 5 .... „ , ..,(.;,-,,,,_, ....,...,--..,, ._.> .. Ag-alg.P. OU - ki . OT. E.-3 ' ,... • W,-.:, ,. .i ., ::' ,. .= . - i : , ,,- F l..p e r , rf - , - y.apw , A ,g5 tr.t...:. .r----, --:..:‘: , ,.-- - ::::1 , -- , A - ....0 .,,,p - : Q . f it,. 44 '5:t.:V ' i ,' nese arowings ano specmcauons are tne connoentiat aria proprietary properly of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue dote and are not suitabFe for use on n different site or at a later time. Use of these drawings for reference or example an another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. LIJ0 -4 I CI r, 1 - 1 1 Doge! r M ' u-7-am °A.V.H M-XPW 0!FPL S il.11 001 c.TANPARP U ILX?I N T f IND i WI?, T:1 T 1:3 T Nr===.; DESCRIPTION vrov EEARTMS NP-4-t-S NV EXTERICM STUCCO FIMISR G. 61 ife 7 0 045 — G GOO5 a a 00 o 0 I I L 1 /4 = - il - ' SEE DK, WING P-a3.2 van PLUMBING LEGEND. 2 SEE DRAWING P -0.0 F06 GENERAL PLUMBING NOTES. 3. SEE DRAWING P-3a2 FUR PLUMBING FIXTURE SCHEDULES AND DETAILS. 40 SEE DRAWING P °2.0 FOR PLUMING ROUGH—INS. PR AN N N 7'5 II II II I I II ri SANITARY UNE TO SANITARY SEWER (SEE SETS PLAN FOR CONTINUATION) GREASE LINE TO EXTERIOR GREASE INTERCEPTOR (SEE SITE PLAN FOR CONTINUATION) STORM LANE TO STORM SYSTEM (SEE SITE PLAN FOR CONTINUATION) TERMINATE OVERFLOW DRAIN AS HIGH AS POSSIBLE WITH DOWNSPOUT COVER TERMINATE OVERFLOW DRAIN A VE TRELLIS WITH DOWNS "3 UT COVER TERMINATE OVERFLOW DRAIN I2 A , VE FINISHED FLOOR WITH EtOWNSPOI T COVER r VENT THROUGH SIDE WALL -- TERMINATE WITH RIRDSCREEN c P� PLUMBING CONTRACTOR SHALL COORDINATE FLOOR DRAIN LOCATIONS WITH P cDONALD ° S AREA CONSTRUCTION MANAGER AND SWAM, VERIFY THAT FLOOR DRAIN LOCATIONS MEET LOCAL CODE REQUIREMENTS (DISTANCE FROM TRAP TO VENT) PLUMBING CONTRACTOR SMALL ROUTE PLAYPLACE VENT PIPE SUCH THAT IT AVOIDS THE UPPER LEVEL GLASS 1)G68- V17 REVIEWED I OR. \ ta__ CODE COMPLIANCE AP EVE SEP 1 8 2000 CIS Tukwila RECEIVED CITY OF TUKWILA SEP 1 1 2008 PERMIT CENTER • 2 1!2 10' -11 1010 11.1 PIPE SIZE PIPE LENGTH LOADING ON PIPE LENGTH • • CHAS PIPE FROM SERVICE MAIN SEE- 5I _h PLAN FOR CONT I NUAT I ON HVAC DEMANPg 640 M H KITCHEN DEMAND3 4a0 MOH HOT HATER I° MAND o I gg MOH TOTAL PEMANDs `WCAL=n 1/4"= SERVICE REGULATOR GAS M2®1 ER I rIcI MI H 2-1/2" NAT. GAS MAIN SLEEVED THRU !ALL AT 10 A.F.F. 2 -1 2 I , -19 '— 1319 Ml 2-1 2 2 1319 tali 1" 112 -8 100 P41I3N I UP SI -0" TO HVAC UNIT (1: -2) 2p -1 cy2 10 -2 1 on M 1) UP 5 TO HVAC UNIT (K -1 ) a -2' 799 MsHI 2 Fa n • 559 MOH cI-•O" TO 1 1/2 9 MOH Y ., 19 2" 100 MI1H9 r HIN SEE DRAM P3.2 FOR PLUMBING LEGEND. 2. SEE DRtWJ1N1G po.0 FoR GENERAL PLU 1rING NOTES. SEE DEMING P3.2 FOR PLUMBING FIXTURE SCHEDULES AND DETAILS. ro SEE DRAWING ;'2d0 FOR PLUMBING ROUGH-INS. 1) ° PM cI 1 - p" TO 5 - VAT FRYER 5AS paldiAND 1314 1 5 ER PI No TO scALE Oh" HVAC UNIT ON ROOF (K-2) 100 MOH IS11 _ � HVAC UNIT ON ROOF ( K1) 150 MOH 5-VAT FILET FRYER 240 Nt Q 0 0 0 1 Yy HVAC UNIT ON ROOF (P-1) 100 Mk CJ 0 -VAT FRENCH POMESTIC 1" 1 (L' HATER I -EATIER 240 H 1 MOH GA5 COCK 1) °- HVAC UNIT ON PQQF (P G 1i?iO MEM PIPE PENETRATION THRU BUILDING STRUC T U E a I OV I DE PIPE SLEEVE AS REWIRED, SAS METER/REGULATOR GAS PIPING UP THRU THE ROOF. COORDINATE l I ROOF P E N T A T I C A N ! 4I T H AC UNIT LOCATION I N THE FIELD. AUTQNATI C GAS SHUT- Oi''°r-' VALVE PART OF AN 'sUL PAcKAGE REVIEWED FOR — 1 CODE COMPLIANCE i SEP 1 8 2008 City of Tukwila BUILDIK DIVISION__ RECEIVED CITY OF TUKWILA SEP 1 1 ZOOM PERMIT CENTER 1 r) rz " Af • 0 0 C -0 C O v a 9 Q 4 a J UI .0 u q? 0 - 0 E 0 0 N U 0 U Lt. '(n U�' G ,VI , N ..- ' - tl U u L o j c U a U Q .�- :2002vco C U L � U g F, I 0.1 ` -, o. a 6: I 6 04(e5 -0005.00,0 0 � PIPING —GAS 0 0 1 160 1r P2 101 00 i (] 25 00 ED- 1' UINE , y HA 65014 { 101. - -1'1) 10100 OPTIONAL !R!ARENA5HER 101.0 15200 52001 101 .10 100.0 65000 1010 PI (3010011 Pl) 32000 o1a 3G10I5 2 1000 Fl 101 .1 101.10 P1 3c1015 31015 3`10 15 3c1.15 11601 11501 P1 to 51.051 P1)- 1 310Q 31.00 P6. 101.10 1 = 1Y\ (._i°1 e _1 E -P> ( °L4 PI P2 P5 5q.00 3coO0 30 - -6 ( HOLD) 34 1 - 1 -1' \ -0" ( S( 0 I 9 1` 0 HOLP) 1' _4" •. 3 11 . 4 24001 PS 44'-5" 11-1-AS i t CJ20 OO 2 02000 0 024001P1 025002P1 02q 0 O 1 P2 O2Gi 0 01 Per 051.0 1 DE` PIH I I ON 2 ICE? TEA BRENER €s PORTABLE SERVER SPEcIALTY t. OPI ! ' ORANGE JUICE DISPERSER SODA TO - GOLD PLATE - 5 VALVE - LEVER CONTS OL- SSA SYSTEM PACKAGE 50I01 0(1 IRCULATING- a TOE ) SODA SYSTEM PACKAGE 1 0I050(RECIP,CULATING- W TOI ) SODA SYSTEM PACKAGE £S 0 I a 15 0( I I CUL..ATI NG- S TOPS) REVERSE OSMOSIS HATER FILTRATION SYSTEM - PRESSURE GAUGE NON I TOR RevERae Cemo515 HATER FILTRATION SYSTEM - PRESSURE GAUGE tom/ N I TOR N a v a F ' 5 E O S M O S I S HATeR FILTRATION SYSTEM - 20 GAL. TANK ICE MAOHIN'• - 500 L5. ICE MACJ I NE - 500 LB. I CE MACHINE - 1000 LB. ICE MA} I -- 1000 LB CO2 FILL BOX S -VAT FRYER -- c3AS - F/F/F 5-VAT FferaR - GAS - 5/5/5 051. 0S 1 SOPA SYSTEM PACE 150I0B0(REOI3° ULAr XNG- 5 TOP ) 032.00F1 002 0 0002 052.01P1 05.00P1 05 SODA SYSTEM PPOI A E 10 1 0150 (1=>:ECIRCUL.ATIN - S T OA ) 240,000 6" PVC. GONPUIT SODA BUNDLE 5/5° R.O. 5/6" R00. 1 /2° FILTH 6" PVC CONDUIT FIG LINE 100.15P1 700022P1 100.22F2 /01.04F1 1010O5P1 MOP SINK (-HAND SINK WATER HEATER - SEALED COMBUSTION -- OAS HATER HEATER SEALEP COMBUSTION - HATER GL ET - APA LAVATORY - VANITY 5/4 5/4' 140 5/4" 5/ 5/4 5/4 LINE REFRIG LINES 5/a" SEE INKS 5/4' CONDENSATE NSATE DRAIN LINE N I R E T U R N SEND l,; T RAP -•SUPP 0 BY REERIG. CONTRACTOR OPENING POR 5/4" GONDEN' rA I OM DRAIN L :: NE -SEALS HEATHER TIGHT BY GC RUN TO a.amoTE coNDERsING UNIT-INSULATE FULL RIJN LENGTH-INSTALLED 5( RE i I G. CONTRACTOR 5/4 COMPENSATE DRAIN LINE NIRETURN BEND N C TRAP-SUFF. BY 1' EF I S 0 CONTRACTOR OPENING 1=0R 5/4" GoNIPENISA T ] ON DRAIN LINE-SEALED HEATHER TIGHT BY GC PG TO Pr OV I P E AND INSTALL 1 ND I REOT DRAIN P I P 1 1 AND MAKE All FINAL CONNECTIONS PO TO MAKE FINAL CONNECTIONS PER LOCAL_ CODE 1 1 /2" D 551 EXTENDS OM LINE N O '1 r' 0 0 0 SYsTEm a TERM 0 DIE MN OPEN SITE, INDIRECT MAIN PC TO MAKE FINAL CONNECTIONS PER LOCAL _ CODE PC MAKES FINAL MNEGTIONS PLR LOCAL GOO DN OHASE FROM SSA SYSTEM - IF NO CHASE RUN IN 2'00NID TO J3 -BSI TO CONN CA LINE, LOCAL CODES FERMITTING 134.001E1 151051P2 1510511' I52001P1 1600O1P1 VEGETABLE SINK 1150I1F1 115.111E2 115.111=5 1160154 1 1Q .1 efF 1 1 16 01 0 1P2 T00002P1 100.05P1 101 002P1 10100SPI 101.061E1 /01.011E1 /01020E1 101.25P1 NORK SINK- 5 COMPARTMENT- c10° WIDE - RIGHT HAND 1ORK SINK- 5 COMPARTMENT- CPO° WIDE - RIGHT HAND NA 1ASH R - UPRIGHT SMART SHAPE SYSTEM COOLER EVAPORATOR - Al l - GOOD COOL. EVAPORATOR - AIR- G00LE-P COOLER EVAPORATOR - AIR - COOLED FREEZER EVAPORATOR -• AIR-COOLED SMOOTH I E MACHINE NE LAVATORY - HALL HUNG G 7010051E1 /01010P1 5" FLOC DRAIN 3 FLOOR SINK - 1 /2 GRATE 0" FLOOR DRAIN WITH FUNNEL 4" FLOOR DRAIN 4" FLOOR DRAIN M/ 4 "x3 FUNNEL 5/ r 5/4 5/5" R.O. I -1 / 2 INRAIN 211 VEN, 2u V SEE t SEE RM 5° DRAIN 2 1/2" }7 2" HASTE o 1'-5" AY M Ti-} 1 1/2 VE��N�T UP - HAT ER L 11' o i ' -10" '4;l1 =1 10 DEGREES - MOUNT SINK BOWL RIM o 04" A.F.F. SEE ( =115 4° DRAIN 5° DRAIN 5° DRAIN 50 DRAIN 5 FAIN 3° DRAIN 4° DRAIN 4° DRAIN HN C1N M 150 PL B6 NGT AFF DRAIN REQU I t E NTS tr REMARKS I MATER LINE REGUIREMENTS0 RECIRCULATED e ED - OF•ANE : JUICE !7 I SPENS Ei F I L EREl - GLEAN --• I N -PLACE FANEi - SMOOTH i E MACHINE IR AA°rA r -- ICE MACHINE -- ICED TEA BRENER REVERSE OSM0S I S - COFFEE BJ° Pal tiER - ESPRESSO MACHINE - FILET I °"1 SUN STEAMER VIP = VerE In 1=7QIci PO = P I of ang GontrarA r 551: = Beverage Syatem Installer 6A5 13Th 240, 000 ( HOLD) SAS S I ?.Fa WI GW MIS G PLB6 5/4° 1/2° TOTED 6" PVC CONDUIT SODA BUNDLE 5 /5° OUTLET SODA BUNDLE 3/8" INLET 5/5" OUTLET 5 /S° INLET 1/2 T1ATEP IIG LIB - f45T AI SEE FNKS SEE Ri '1 SEE lKS RMKS S Pr KS R 01K.S S 3 - 6 1 IRIS LINES SEE 1(S SEE RHK SEE S SEE l2MK5 1/2" FILTEREP SEE RmKs I I ' -2" ( MOLP) INSTALL THIS SECTION OF THE S AS POSS I SLE 50 THAT THE BOTTOM OF ( ON NON- CLEARSPAN t51J I LD I N6S ABOVE THE BOTTOM OP THE 8001 DRAIN yea REQUIREMENTS 11 EMENTS 4 REMARKS LEEVE A5 M THE SLEEVE 15 ONLY) JOISTS ABOVE CEILING FROM SODA SYSTEM - TERMINATE AT CHASE PN CHASE SODA SYSTEM - "T" FROM PIT IF REQUIRED - 551 TO MAKE FINAL CONNECT I ONSS- , LOCAL CODES PT MITT I PN CHASE FROM R.O. SYSTEM - IF NO CHASE RUN IN 2 "CONY? TO J5 -B 9I TO CONN C)i'I LINE, LOCAL COPES Pte} i TT I Nl: ION 1 G - } A S PROM F O . SYSTEM - IF NO CHASE RUN IN 2° GONP TO J5 --BSI TO GONN Chid LINE, LOCAL. WOES PERMITTING DN CHASE FROM SODA TOWER CA LINE W/ 1 EG I RG /C H I I LEP INSULATED BUNDLE-BSI GONN OWL I N , LOCAL CODES FERM I TT I NG 17N CHASE FROM SODA SYSTEM - I F NO CHASE RUN IN 2" CONY TO J5 -BSI TO CONN ON LIFE, LOCAL COPES PERMITTING ABOVE CEILING FROM SOPA SYSTEM - TERMINATE AT CHASE PN GHQ FROM SODA SYSTEM - 551 ' TO MAKE FINAL CONNECTIONS, LOCAL COPES PERMITTING FLEX LINE OVERHEAP TO VARIOUS EQUIP. SEE HATER LINE 1ECt 0 THIS SHITT 0 -I I TO MAKE FINAL COMM, LOCAL GO17' NI TTI 'S OVERHEAD TO SODA TOMER CHASE( 5) - SUPFL I ED BY f C OVERHEAD TO SOPA TOIL CHASE( E0 -- 551 TO MAKE FINAL CONNECTIONS, LOCAL CODES PERMITTING PG TO MAKE CONNECT I ON FROM HALL L LOCATION TO SODA SYSTEM (VERIFY HEIGHT IN FIELD) FROM REMoie GONEINS UNIT FLEX LINE OVERHEAD Ml_ SODA SYSTEM BOOSTER-BSI TO MAKE FINAL CONN, LOCAL COPES NMI rT I MS 0 100 PSI MIND PRESSURE FLEX LINE OVEN TO 20 GAL. TANK 0 -t 5 I TO MAKE P I HAL GONN, LOCAL CODES PERMITTING FLEX LINE OVERHEAP FROM PRESSURE GAUGE MON I TOR -BSI TO MAKE FINAL COMM, LOCAL COVES PERMITTING CONNECT TO SODA SYSTEM PACKAGE EL EX LINE OVERHEAD PROM SODA SYSTEM - S5 I TO MAKE FINAL CONNECTIONS, LOCAL. COPES PERMITTING P- GHARSEr REFRIGERATION L I N- S OVERHEAP FROM REMOTE CONDENSING UNIT FLAX LINE OVERHEAD FROM SODA SYSTEM - 135 I TO MAKE FINAL_ CONNECTIONS, LOCAL- GOPES P1 M I TTI NG -CHARGED IGERATION LINES OVERHEAP FROM REMOTE CONDENSING UNIT HEIGHT 15 TO CENTERLINE Or FILL SOX: INSTAL r ED BY 5000 EXTEND? (1) OAS LINE DN CHASE AFTER EOUIPMENT I TE1( S) INSTALLED EXTEND (1) SA5 LINE DM CHASE AFTER EQUIPMENT ITEM(5) INSTALLED VIF = VYrrfy In F 1 &1d P G = P I umi) I ng Contractor 55I = l'verago System I mica I I er0 TA6 QTY P SGR I PT ION rL 600. C ONSTRI,JGTED CHASE TO 10 "11 X 15"H OPENI FOR ROUTING BEVERAGE LINES TO SELF SERVE FROM CEILING N6 AT FLOOR 4 UTILITY EG11J I PMENT SAS TYPE SAS GAS BTU SIZE I I J 0 REVIEWED FOR CODE COMPLIANCE Wp OV ELI SEP 18 2000 City O Tukw l O Go g= 1 RECEIVED CITY OF TUK MLA SEP ,1 1 2008 PERMIT CENTER Ii HEIGHT IS TO CENTERLINE OF FILL BOXp iNSTALI E9 BY G.C. PC TO VERIFY WATER HEATER INSTALLATION iHEIGHT - SEE PLUMBING NG SPECIFICATION LEGEND FOR ADDITIONAL INFO IATIOi l PG TO VERIFY YiA ER HEATER INSTALLATION I4E I G1-} r - 5E2 PLUMBING ,S' Per i I P I GAT I OM LEGEND I ID FOR ADDITIONAL INFORMATION SEE PLUMBINs SPECIFICATION L. ND FOR A P I T 10NAL I NF ORM1 t I ON SEE PLUMBING SPECIFICATION LEGEND FOR ADDITIONAL I NF RMATI ON SEE PLUMBING SPECIFICATION LEGEND ADDITIONAL INFORMATION SEE FLUMB I NG SPECIFICATION LEGEND FOR ADDITIONAL INFORMATION - MOUNT SINK e0AL 1~'1M 0 04 A.F.E. SEE PLUMBING I 1 I OAT I ON LEGEND FOR ADDITIONAL ] NFORMA' T 10N - MOUNT SINK BO;r1LL RIM o 4" A.P.F. SEE PLUMBING SPECIFICATION LEGEND FOR ADDITIONAL INFOMATION SEE PLUMBING SPECI F I GATI ON LEGEND FOR ADDITIONAL_ I Ni O HAT I ON SEE PLUMBING SPL I F I GAT I ON LEGEND FOR ADD I T I OHAI- INFORMATION s EEE PLUi'B I NG SPEGIFICATION L_EGENO PG Z ADDITIONAL I lNFORMAT i ON PLUMBING 5PEOIFIOATION LEGEND FOR ADDITIONAL INFORMATION fi (77X4 Pm Ji �r - e� L U O ^ N L � N C i 1 -S O N �' �.. o 0.1 L 0 - -2-a •L r o ici: V ) - U "- pig 20 ' _ J a 0 L� -' 11 0 a 0 G U C]. p -v - ::',- Oc5 C c 0j Q 7 O a In c (J I- L U � N'� U 0? wv a 0) E -0 Cl 0 C fl 0 U c "0 y 0 -0 o N 0 0 j ° -0 -J ai 0 ri U � In .2 v1 C - U s: a , .N 4 .. E1 Ci "U U ., e> O V •a q 00 E co 0 x 01E 0 L 0t5 C 0 C 0 01 U O `1 47 C V U)._ C O �? U c)-' O � Uo U 0 0 a 15) cx A'^;+x kJ QU6i-4- I N PL AN 111 0 I '0 1 I! i f2 trl 0,4s-0005,,000p a ril`.' I ` 4 � f i 1 4 0 0 1 160 1r P2 101 00 i (] 25 00 ED- 1' UINE , y HA 65014 { 101. - -1'1) 10100 OPTIONAL !R!ARENA5HER 101.0 15200 52001 101 .10 100.0 65000 1010 PI (3010011 Pl) 32000 o1a 3G10I5 2 1000 Fl 101 .1 101.10 P1 3c1015 31015 3`10 15 3c1.15 11601 11501 P1 to 51.051 P1)- 1 310Q 31.00 P6. 101.10 1 = 1Y\ (._i°1 e _1 E -P> ( °L4 PI P2 P5 5q.00 3coO0 30 - -6 ( HOLD) 34 1 - 1 -1' \ -0" ( S( 0 I 9 1` 0 HOLP) 1' _4" •. 3 11 . 4 24001 PS 44'-5" 11-1-AS i t CJ20 OO 2 02000 0 024001P1 025002P1 02q 0 O 1 P2 O2Gi 0 01 Per 051.0 1 DE` PIH I I ON 2 ICE? TEA BRENER €s PORTABLE SERVER SPEcIALTY t. OPI ! ' ORANGE JUICE DISPERSER SODA TO - GOLD PLATE - 5 VALVE - LEVER CONTS OL- SSA SYSTEM PACKAGE 50I01 0(1 IRCULATING- a TOE ) SODA SYSTEM PACKAGE 1 0I050(RECIP,CULATING- W TOI ) SODA SYSTEM PACKAGE £S 0 I a 15 0( I I CUL..ATI NG- S TOPS) REVERSE OSMOSIS HATER FILTRATION SYSTEM - PRESSURE GAUGE NON I TOR RevERae Cemo515 HATER FILTRATION SYSTEM - PRESSURE GAUGE tom/ N I TOR N a v a F ' 5 E O S M O S I S HATeR FILTRATION SYSTEM - 20 GAL. TANK ICE MAOHIN'• - 500 L5. ICE MACJ I NE - 500 LB. I CE MACHINE - 1000 LB. ICE MA} I -- 1000 LB CO2 FILL BOX S -VAT FRYER -- c3AS - F/F/F 5-VAT FferaR - GAS - 5/5/5 051. 0S 1 SOPA SYSTEM PACE 150I0B0(REOI3° ULAr XNG- 5 TOP ) 032.00F1 002 0 0002 052.01P1 05.00P1 05 SODA SYSTEM PPOI A E 10 1 0150 (1=>:ECIRCUL.ATIN - S T OA ) 240,000 6" PVC. GONPUIT SODA BUNDLE 5/5° R.O. 5/6" R00. 1 /2° FILTH 6" PVC CONDUIT FIG LINE 100.15P1 700022P1 100.22F2 /01.04F1 1010O5P1 MOP SINK (-HAND SINK WATER HEATER - SEALED COMBUSTION -- OAS HATER HEATER SEALEP COMBUSTION - HATER GL ET - APA LAVATORY - VANITY 5/4 5/4' 140 5/4" 5/ 5/4 5/4 LINE REFRIG LINES 5/a" SEE INKS 5/4' CONDENSATE NSATE DRAIN LINE N I R E T U R N SEND l,; T RAP -•SUPP 0 BY REERIG. CONTRACTOR OPENING POR 5/4" GONDEN' rA I OM DRAIN L :: NE -SEALS HEATHER TIGHT BY GC RUN TO a.amoTE coNDERsING UNIT-INSULATE FULL RIJN LENGTH-INSTALLED 5( RE i I G. CONTRACTOR 5/4 COMPENSATE DRAIN LINE NIRETURN BEND N C TRAP-SUFF. BY 1' EF I S 0 CONTRACTOR OPENING 1=0R 5/4" GoNIPENISA T ] ON DRAIN LINE-SEALED HEATHER TIGHT BY GC PG TO Pr OV I P E AND INSTALL 1 ND I REOT DRAIN P I P 1 1 AND MAKE All FINAL CONNECTIONS PO TO MAKE FINAL CONNECTIONS PER LOCAL_ CODE 1 1 /2" D 551 EXTENDS OM LINE N O '1 r' 0 0 0 SYsTEm a TERM 0 DIE MN OPEN SITE, INDIRECT MAIN PC TO MAKE FINAL CONNECTIONS PER LOCAL _ CODE PC MAKES FINAL MNEGTIONS PLR LOCAL GOO DN OHASE FROM SSA SYSTEM - IF NO CHASE RUN IN 2'00NID TO J3 -BSI TO CONN CA LINE, LOCAL CODES FERMITTING 134.001E1 151051P2 1510511' I52001P1 1600O1P1 VEGETABLE SINK 1150I1F1 115.111E2 115.111=5 1160154 1 1Q .1 efF 1 1 16 01 0 1P2 T00002P1 100.05P1 101 002P1 10100SPI 101.061E1 /01.011E1 /01020E1 101.25P1 NORK SINK- 5 COMPARTMENT- c10° WIDE - RIGHT HAND 1ORK SINK- 5 COMPARTMENT- CPO° WIDE - RIGHT HAND NA 1ASH R - UPRIGHT SMART SHAPE SYSTEM COOLER EVAPORATOR - Al l - GOOD COOL. EVAPORATOR - AIR- G00LE-P COOLER EVAPORATOR - AIR - COOLED FREEZER EVAPORATOR -• AIR-COOLED SMOOTH I E MACHINE NE LAVATORY - HALL HUNG G 7010051E1 /01010P1 5" FLOC DRAIN 3 FLOOR SINK - 1 /2 GRATE 0" FLOOR DRAIN WITH FUNNEL 4" FLOOR DRAIN 4" FLOOR DRAIN M/ 4 "x3 FUNNEL 5/ r 5/4 5/5" R.O. I -1 / 2 INRAIN 211 VEN, 2u V SEE t SEE RM 5° DRAIN 2 1/2" }7 2" HASTE o 1'-5" AY M Ti-} 1 1/2 VE��N�T UP - HAT ER L 11' o i ' -10" '4;l1 =1 10 DEGREES - MOUNT SINK BOWL RIM o 04" A.F.F. SEE ( =115 4° DRAIN 5° DRAIN 5° DRAIN 50 DRAIN 5 FAIN 3° DRAIN 4° DRAIN 4° DRAIN HN C1N M 150 PL B6 NGT AFF DRAIN REQU I t E NTS tr REMARKS I MATER LINE REGUIREMENTS0 RECIRCULATED e ED - OF•ANE : JUICE !7 I SPENS Ei F I L EREl - GLEAN --• I N -PLACE FANEi - SMOOTH i E MACHINE IR AA°rA r -- ICE MACHINE -- ICED TEA BRENER REVERSE OSM0S I S - COFFEE BJ° Pal tiER - ESPRESSO MACHINE - FILET I °"1 SUN STEAMER VIP = VerE In 1=7QIci PO = P I of ang GontrarA r 551: = Beverage Syatem Installer 6A5 13Th 240, 000 ( HOLD) SAS S I ?.Fa WI GW MIS G PLB6 5/4° 1/2° TOTED 6" PVC CONDUIT SODA BUNDLE 5 /5° OUTLET SODA BUNDLE 3/8" INLET 5/5" OUTLET 5 /S° INLET 1/2 T1ATEP IIG LIB - f45T AI SEE FNKS SEE Ri '1 SEE lKS RMKS S Pr KS R 01K.S S 3 - 6 1 IRIS LINES SEE 1(S SEE RHK SEE S SEE l2MK5 1/2" FILTEREP SEE RmKs I I ' -2" ( MOLP) INSTALL THIS SECTION OF THE S AS POSS I SLE 50 THAT THE BOTTOM OF ( ON NON- CLEARSPAN t51J I LD I N6S ABOVE THE BOTTOM OP THE 8001 DRAIN yea REQUIREMENTS 11 EMENTS 4 REMARKS LEEVE A5 M THE SLEEVE 15 ONLY) JOISTS ABOVE CEILING FROM SODA SYSTEM - TERMINATE AT CHASE PN CHASE SODA SYSTEM - "T" FROM PIT IF REQUIRED - 551 TO MAKE FINAL CONNECT I ONSS- , LOCAL CODES PT MITT I PN CHASE FROM R.O. SYSTEM - IF NO CHASE RUN IN 2 "CONY? TO J5 -B 9I TO CONN C)i'I LINE, LOCAL COPES Pte} i TT I Nl: ION 1 G - } A S PROM F O . SYSTEM - IF NO CHASE RUN IN 2° GONP TO J5 --BSI TO GONN Chid LINE, LOCAL. WOES PERMITTING DN CHASE FROM SODA TOWER CA LINE W/ 1 EG I RG /C H I I LEP INSULATED BUNDLE-BSI GONN OWL I N , LOCAL CODES FERM I TT I NG 17N CHASE FROM SODA SYSTEM - I F NO CHASE RUN IN 2" CONY TO J5 -BSI TO CONN ON LIFE, LOCAL COPES PERMITTING ABOVE CEILING FROM SOPA SYSTEM - TERMINATE AT CHASE PN GHQ FROM SODA SYSTEM - 551 ' TO MAKE FINAL CONNECTIONS, LOCAL COPES PERMITTING FLEX LINE OVERHEAP TO VARIOUS EQUIP. SEE HATER LINE 1ECt 0 THIS SHITT 0 -I I TO MAKE FINAL COMM, LOCAL GO17' NI TTI 'S OVERHEAD TO SODA TOMER CHASE( 5) - SUPFL I ED BY f C OVERHEAD TO SOPA TOIL CHASE( E0 -- 551 TO MAKE FINAL CONNECTIONS, LOCAL CODES PERMITTING PG TO MAKE CONNECT I ON FROM HALL L LOCATION TO SODA SYSTEM (VERIFY HEIGHT IN FIELD) FROM REMoie GONEINS UNIT FLEX LINE OVERHEAD Ml_ SODA SYSTEM BOOSTER-BSI TO MAKE FINAL CONN, LOCAL COPES NMI rT I MS 0 100 PSI MIND PRESSURE FLEX LINE OVEN TO 20 GAL. TANK 0 -t 5 I TO MAKE P I HAL GONN, LOCAL CODES PERMITTING FLEX LINE OVERHEAP FROM PRESSURE GAUGE MON I TOR -BSI TO MAKE FINAL COMM, LOCAL COVES PERMITTING CONNECT TO SODA SYSTEM PACKAGE EL EX LINE OVERHEAD PROM SODA SYSTEM - S5 I TO MAKE FINAL CONNECTIONS, LOCAL. COPES PERMITTING P- GHARSEr REFRIGERATION L I N- S OVERHEAP FROM REMOTE CONDENSING UNIT FLAX LINE OVERHEAD FROM SODA SYSTEM - 135 I TO MAKE FINAL_ CONNECTIONS, LOCAL- GOPES P1 M I TTI NG -CHARGED IGERATION LINES OVERHEAP FROM REMOTE CONDENSING UNIT HEIGHT 15 TO CENTERLINE Or FILL SOX: INSTAL r ED BY 5000 EXTEND? (1) OAS LINE DN CHASE AFTER EOUIPMENT I TE1( S) INSTALLED EXTEND (1) SA5 LINE DM CHASE AFTER EQUIPMENT ITEM(5) INSTALLED VIF = VYrrfy In F 1 &1d P G = P I umi) I ng Contractor 55I = l'verago System I mica I I er0 TA6 QTY P SGR I PT ION rL 600. C ONSTRI,JGTED CHASE TO 10 "11 X 15"H OPENI FOR ROUTING BEVERAGE LINES TO SELF SERVE FROM CEILING N6 AT FLOOR 4 UTILITY EG11J I PMENT SAS TYPE SAS GAS BTU SIZE I I J 0 REVIEWED FOR CODE COMPLIANCE Wp OV ELI SEP 18 2000 City O Tukw l O Go g= 1 RECEIVED CITY OF TUK MLA SEP ,1 1 2008 PERMIT CENTER Ii HEIGHT IS TO CENTERLINE OF FILL BOXp iNSTALI E9 BY G.C. PC TO VERIFY WATER HEATER INSTALLATION iHEIGHT - SEE PLUMBING NG SPECIFICATION LEGEND FOR ADDITIONAL INFO IATIOi l PG TO VERIFY YiA ER HEATER INSTALLATION I4E I G1-} r - 5E2 PLUMBING ,S' Per i I P I GAT I OM LEGEND I ID FOR ADDITIONAL INFORMATION SEE PLUMBINs SPECIFICATION L. ND FOR A P I T 10NAL I NF ORM1 t I ON SEE PLUMBING SPECIFICATION LEGEND FOR ADDITIONAL I NF RMATI ON SEE PLUMBING SPECIFICATION LEGEND ADDITIONAL INFORMATION SEE FLUMB I NG SPECIFICATION LEGEND FOR ADDITIONAL INFORMATION - MOUNT SINK e0AL 1~'1M 0 04 A.F.E. SEE PLUMBING I 1 I OAT I ON LEGEND FOR ADDITIONAL ] NFORMA' T 10N - MOUNT SINK BO;r1LL RIM o 4" A.P.F. SEE PLUMBING SPECIFICATION LEGEND FOR ADDITIONAL INFOMATION SEE PLUMBING SPECI F I GATI ON LEGEND FOR ADDITIONAL_ I Ni O HAT I ON SEE PLUMBING SPL I F I GAT I ON LEGEND FOR ADD I T I OHAI- INFORMATION s EEE PLUi'B I NG SPEGIFICATION L_EGENO PG Z ADDITIONAL I lNFORMAT i ON PLUMBING 5PEOIFIOATION LEGEND FOR ADDITIONAL INFORMATION fi (77X4 Pm Ji �r - e� L U O ^ N L � N C i 1 -S O N �' �.. o 0.1 L 0 - -2-a •L r o ici: V ) - U "- pig 20 ' _ J a 0 L� -' 11 0 a 0 G U C]. p -v - ::',- Oc5 C c 0j Q 7 O a In c (J I- L U � N'� U 0? wv a 0) E -0 Cl 0 C fl 0 U c "0 y 0 -0 o N 0 0 j ° -0 -J ai 0 ri U � In .2 v1 C - U s: a , .N 4 .. E1 Ci "U U ., e> O V •a q 00 E co 0 x 01E 0 L 0t5 C 0 C 0 01 U O `1 47 C V U)._ C O �? U c)-' O � Uo U 0 0 a 15) cx A'^;+x kJ QU6i-4- I N PL AN 111 0 I '0 1 I! i f2 trl 0,4s-0005,,000p a ril`.' Kg\PIV\NEST\- NORTHNEST\040-0005-00-0 TUKKILA, 1NA\4531FF-1'K_F3-0_P5-1_P5-2.G6 04-11-2003 14g50; (2. 1 N0 TETLE ; -7) 001 07ES- cv 6EN-7,15 NA( ! S V EX STLY— FY-F -f s CT R NSH S 2 TB e D F., L.= FL- STAND ,r- E ,.../•r-t of 3 a irAI I 7 i-•••. 1 •• 1 7 IL" u I 1NR x Th a o o % DAK:\1 BY OGKINI= ,A.R.opv:-7./aNn-Ry. 06T 2001 STD K a DA - — CL1 -l=••• -ts• = 1-1/2 f.1 FA FOR: A I I 1/2" i" These drawings and specifications are the confidential and proprietary property of McDonald's USA, LLC and shell not be copied or reproduced without written. authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and ore riot suitable for use on ' different site or at a loter time. Use of these drawings for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. T'LliCULA a 3/4" ©2007 McDonald's USA, LLC 3/4" V sh— El / 0 / _29 f<1 ------------------------- -------- BY aloDark aka acear.-.4 L 03020 1 " 41_ n a Na 0 2/2" 1/2' I / 3/4" a nocsagbp&J Ppori'esdieRgiD ErdigiiRew I a I I I \ ,,i1/21 a „ ,, ,, i ' \ N \,‘ \ , \ ;4 , A 1,, A 't A A A t,, A \ A A .21 .et ...■............• ... .... A A A A A ‘ A 1 . 1 . 1 . r 3/4” A % ‘ r‘1 1 ; . \ 17.,e NY — '\ '‘ % . '1 . e \ . \\ '4 0 \\ / e 1 1 I % ) 1 0 ' &.- % - 1. ./ / \ C / / I V- I / "Li e . , . P / \ e 6 '3 C 7 A . ls!) e ' e '4 a ,-4 •• 3 ' "";•"' jagAD eggenta c9 r • /.;•-••• .0ATE u z -1 r o >0 4 3 r (, N- .--; n o 2 , „:11 L .. : . 1 ! .- ;1 ‘ 2 cl o Lu iH S ti ''''1/2.>1:1 ii. . 7 Lol 1.: 0 .11 617 \Q>u 1 1 1 i n.. . —_jj ha r [ 1 . > < 11 `5;• -; T1 il: " 2: - 1 - 's 77 :--3 4-1 -- I Z 11 [—I < .11 .1. ---> 0 .1> 70 - Z -1 r o H < f__ -, e I ril < -7, o II; TT: ‹1 –1 A Q •--: ..-=. 0 1 ro i .- r 1,3 0 > Of 5 v 0,3 k 0 70 P 0 -z ,:. -i io oorr nT C-4 -n lit ch 73 ( 12 > C. H - 11 Ut •_ I • ,Avr: • 0 - (i) 0 01 cz.1 zg - 7 —I 5 ° iTA C—C c. 0 11 >r _ o .17 0 wai r 1> R cc i<0 3 -... 0 ( c 7l ki 1 m m --- 01 . i ., T - 1 0 1 : - ;K [Ti hi , a r5 c---•a v >, 0 -1 r () (:),--, -, (ft rti 7. rn. - I n s„ -1 YU :1 - 11 X > 0 z k.), , 74 -1 11 > c. •---7 ✓ < - 5 0 0 — o ra < 6 E. O 71 iyp > „. — .‚ -1 - u ,:,,,'.: c t•-• -•,„ i II Z ›: C-- - iSiZ'-' 11 r---1 I- o 1 '7 -- ° ES _ > 1 ,Ila sq, -,z L._ oz 0 ...., c Pf C in=saz ,..- K \E„Tcy\sT A FREL Km\ FRoTo Ty paws eriFF \ er 03-25 ....200 g 0-1 11 J;j () TITLE 200 STANPARD .1 . _ 104-0,006 15210 HAY 6UiLtiN 6 )1 LP N6 !,'":1117.? NI . t fle.".)P ?O WJJ STIJC,C/ 9NsH y TF f 'T D e CGT 2001 P.SEki DATE KSSUrf, GOT 2001 TUjtLU 11 fi 2" -------- V B I -l 2, e 7 „ ©2007 MoDonalcrs USA, LLC IU- These drawings and specifications are the confidential and proprietary properly of McDonald's USA, LLC and shall not be copied or reproduced without written authorization. The contract documents were prepared for use on this specific site in conjunction with its issue date and are not suitable for use on a different site or at a later time_ Use of these drawings for reference or example an another project requires the services of properly licensed architects and engineers. Reproduction of the contract documents for reuse on another project is not authorized. cv 2 " 3Y fl m - 0 asEti eraM; B Ragrzkarc Erggage \ 2 e e \14 WW1. C3.1.3 V39 .13C1:3131 1331.. ■=2.3. 63=1.• 1.013D 03:31=9 C=3131 52.19 CC. CL31513 2 3 / ___IT'; ‘'1/4 14- r Nt.: ..._ . :Ell g' _ 6/ ‘ V 2 i \ P \ 1- ill:- \ '1 . \ 40 \ E-4.0 ' 6 .M. 3241 &3 t'r = 77 e 1 1 e / / \v.), 'U \ / o / \ / \ / el QATiMiV —` •■••••••"."'. , 411 " - 1 REV PATE _ _ . _ _ Or=~;GRI PT ON BY' w ni )?' 170 X . . f j f i I I � i __ -_ ? DETAIL CHEMICAL SYSTEM AT MOP SINK SCAa E: NONE EV I AT I ONS GLEAN --OUT HALL GLEAN -OTT 1=L©Or GLEAN-OUT PG PLUi3I NS GONTRAGTOR OE PAL NT1 ACTOR K I TO -EN E6U I I �lT SUPPLIER Olt► /OF ATOR so I S I i GQNT ACTOR DETAIL NOTES: 1. INCOMING UNDERGROUND WATER SERVICE SIZED PER FIRE PROTECTION CONTRACTOR'S HYDRAULIC CALCULATIONS 2, CONCRETE BLOCKING AT CHANGES ANGES IN DIRECTION 3s I�'IMINIMUM 1 A(�I�UI� -,R CLEARANCE [�,N 4. UNION 3. BRONZE STRAINER 6. QUARTER -TURN ALL VALVE 7. REDUCED PRESSURE ZONE (RR) ASSEMBLY° Go AIR GAP FOR '. LIEF VALVE L PIPING FROM AIR GAP TO FL kIR BRAIN 10. GALVANIZED STEEL PIPE SUPPORTS 11. emir BUSHING 120 1?2" WATER M1rTER' 13 FI i IR DRAIN-PITCH FLOOR TOWARDS DRAIN 14. P -TRAP 15. •PIPE TO SEWER -PITCH AND VENT PER CODE 160 r PIPE FOR WATER SERVICE 17. PIPE EAR FIDE SPRINKLER SYSTEM SIZED PER FARE PROTECTION CONTRACTOR'S HYDRAULIC CALCULATIONS °IRPZ BASED ON WATTS MODEL JOSSQT RRWATEI3 MET'. ' BASED ON NEPTUNE MODEL T -10 INCOMING WATER SERVICE WITH IRPZ, METER AND FIRE SPRINKLER SYSTEM SCALE': )2 "01 a_OR ROOF DEC( FINISHED FINISHED FLOOR NOTES: 1. THERMAL EXPANSION TANK 2. EXTEND WATER HEATER, CONDENSATE AND Tl P DRAINS TO FLOOR D 1N 3 WATER HEATER PRESSURE/TEMPERATURE RELIEF VALVE 4. WATER HEATER 5. VERTICAL GAS FLUE VENT FOR WATER HEATER 6. TEMPERING/ANTI-SCALD VALVE SET AT 110'1'. 7. SWING CHECK VALVE B. B 3 SERIES 100, BRONZE BODY PUMP (RATED FOR 12 GPM 10 15' OF HEAD) ) HP Moron CONTROLLED BY AQUASTAT AND TIMECLOCK Bo BALANCING VALVE 100 STRAP -ON AQUASTAT FOIR PUMP CONTROL 11. SEALED - COMBUSTION CONDENSATE DRAIN 12. GIBS CONNECTION 13. WATER NEATER DRAIN 14. SEALED-COMBUSTION INTAKE AND VENT IS. NOT USED DETAIL WATER HEATER PIPING WITH! RECIIRC (STANDARD) SCALE: NOME faliSEEIMMRSIAINEWAVERI THERMOMETER ' 1 !HW (14g'F) p TEMPERED (110'F) 1Y� DCW FLOOR A I N GLEAN -OUT ( PLOO1 OR YARD) FLOC SINK VENT PIPINS ABOVE e-ROUNI7 STORM P I P I NS UNPEReRoUNp STORM PIPING. HOSE 1311 GOLP WATER PIPING 1 I O° HOT WATER PIPING 14O° HOT WATER PIPING REG I RGULATETJ HOT HATER P I P I Ne OVERT LINES (BY P C. ) CHECK K VALVE 3ALL VALVE THERMOSTAT I G M I X I NS VALVE NOTE: THIS DETAIL IS SHOWN FOR REQUIREMENTS SHALL BE VERIFIER THE CONSTRUCTION M4 AGELR AND SUPPLIER. MOP SINK DRAIN PRODUCT PICK -UP TUBES CONCENTRATE RACK MOP SINK FAUCET OM D" CENTERS MOLD SINK PRE -RINSE SPRAYER 120 °E WATER SUPPLY WITH GRPZ IJU TD1 ACTIVATED DISPENSER w/ AIR GAP EDIJCTOIR0 3--CU IPARTHERT SINE 1/CHARGE TUBES PRODUCT P1CK -UP TUBES REFERENCE ONLY. ALL AND COORDINATED 'R ITH KITCHEN EQUIPMENT �- - BUTTON ACTIVATED CHEMICAL DISPENSER WITH AIR GAP EDUCTOR AND WATER VALVE 1201 WATER SUPPLY WITH RPZ NOTE: MIS DETAIL IS SHOWN FOR REFERENCE ONLY. ALL REQUIREMENTS SHALL BE VERIFIED AND COORDINATED WITH THE CONSTRUCTION MANAGER AND KITCHEN EQUIPMENT SUPPLIER. UN S ROUND WASTE P I P I Nf� PUMP C�EDU E TAG MANUFACTURER MODEL HP V O Hz ACCESSORIES IRP ®1 BELL ; GOSSETT 601 12® 1 6O 9 m� TAO• 112 12® 1 60 a- RP-2 GRLThDFOS UP43 --75F 1 120 BID 1 -3 ACCESSORIES: 1. TIMEILQCK 2e AQUASTAT 3a CHECK VALVE �3C�1 PC WC-2 WC-2 PC UR-1 I PC FD-1 PC FD -3 PC ElL1-4 PC 1B-1 H@-2 H® -3 MS-1 PC NS -1 FTC KS-1 1 I(IES VS-1 1 ISES STANDARD ELF rIR -MOUNT WATER CLOSET APIA FLOOR -MOUNT WATER CLOSET = !A WALL -HUNG URINAL VANITY TYPE LAVATORY WALL- -FLUNG LAVATORY FLOOR DRAIN WITH ROUND FUNNEL FLOOR D o N R DRAIN WITH OVAL FUNNEL AUTOMATIC DRAINING, FI3EEZE L RS, \TI- SIPHON WALL HYDRANT ANTI- SIPHON CLOSE - COUPLED WALL HYDRANT FREEZELESS POST YARD HYDRANT MOP SINK 0 OVAL - STAINLESS STEEL TROUGH) STAINLESS STEEL HAND SINK STAINLESS STEEL HAND SINK - AM DESCRIPTION FLOOR D N FLOOR SINK WASHING MACHINE MANUFACTURER AMERICAN STANDARD AMERICAN STANDARD CURIAN AMERICAN STANDARD WOODFORD 63C WOODFORD B! ADVANCE TABOO PC WATER CLOSET SENSOR FLUSHOMETER SLOAN 1D111 PC URINAL SENSOR FLUSHOMET: FAUCETS C FAUCETS 630 -4 PC CHICAGO FAUCETS 007 1. SIDE MoDQNALD'S PROJECT MANUAL FOR ADDITIONAL MANUFACTURERS SY91 SC STORM WATER INTERCEPTOR 1. SEE McDONAL 'S PROJECT MANUAL FOR ADLDITIONkL MANUFACTURERS ptional Water Heaters PIayPlace Water Heaters 11. 1 Manufacturer LAVATORY FAUCET SENSOR TYPE MOP SINK FAUCET INTEGRAL VACUUM BREAKER F DRAIN OVERFLOW ROOF @'IN OVERFLOW DOWNSPOUT COVER DESCRIPTION EXTERIOR GREASE INTERCEPT® Gas I Sealed acceptable for use with standard 3 -c _ _J Electric SUF100 -150NE Gas Electric in lieu of recirculation sy Sealed ZURN 1 Z121RAIHI Outlet LDtilit T e ]°erra Gas Sealed 140` Electric - 140` 415H --3 ti '' Z -320 41311-3 ZURN 241511 -4 G% 2-320 ZURM 2415H_4 ZURN 21001 -2©3 MS -2424 C-2C 323 FIG-2424 CHS171 &C SEE KITCHEN DRAWINGS ITEM: 1 34.02 SEE KITCHEN DRAWINGS ITEM: 132.01 SEE KITCHEN DRAWINGS 1 ITEM: 223.00 FLUSH VALVES Z122 -HD 2100 -DC-R MANUFACTURER ( ACCESSORIES /COMMENTS GREEN TURTLE P R© ©EPTOR - - 500 GALLONS SEE SITE PLAN MGR LOCATION EE1 TURTLE STORMCEPTOR SEE SITE PLAN FOR 1 LOCATION Water Heaters First hour input delivery Capacity Heating _Oh Gallins Btu /hr kW 1be ° F' rise 100 1 119 - 54 100 199 - 309 119 - 54 ° y 119 - 199 119 - 54 100 199 - L 297 119 - 54 304 ompartment sink only) Sealed 100 15- S - [ 36 1 - 100 150 250 80 - 3 6 - 80 160 85 - 36 - 100 150 - 241 input Heating Delii Btu /hr kW 1ST 180 1 - 95 ° F ry Rate 1 FLUSH �1AW� 2 "x8 GUY GRAY 0 -150 SPACE SAVED BAI L RY- OPERATED WITH COURTESY FLUSH BATTERY- OPERATED WITH COURTESY FLUSH BATTERY - OPERATED 1 I ATTERY- OPERATED Recovery gph 100 ° F rise 227 221 239 223 229 223 227 221 SPECIFY PIPE SIZE (OPTIONAL PVC BODY DRAIN WHERE PERMIiTE SPECIFY PIPE SIZE A.Q. Smith A.Q. Smith Rheem -Ruud Rheem -Ruud BTI -199 � DRE- 120 -54 EF- 100T- 199E -3NA M -1 I- 120A -54 -3 HE- 119 -199 E S 120 -54 -G Bradford White State State A.O. Smith A.O. Smith Bradford White Bradford White Rheem -Ruud Rheem -Ruud State State Electric Gas DRE -80 -36 EF -100T 150E -3NA Gas Electric Gas Electric ® Gas M- I1- 80A -36 -3 HE-80-160 Sealed Electric Gas Sealed Electric Sealed Sealed SUF100 -199NE CSB120 -561FE Sealed _ Dimensions Tank Control Dia. Pane n. Ira. 27.75 29.50 28.25 30.00 27.00 30.25 27.75 29.50 0.00 6.25 0.00 7.25 9.00 5.75 0.00 6.25 35.75 28.25 37.25 36.00 36.00_ 27.75 35.75 Overall 208 120 208 120 171 27.75 0.00 27.75 120 J 1 148 MN 6.00 31.25 208 3 180 28.25 0.00 28.25 F 1 149 26.00 6.50 32.50 1 184 23.50 8.50 32.00 120 17 149 28.25 5.75 34.00 208 E 3 171 27.75 0.00 27.75 120 ; T fa 25.25 6.00 31.25 208 i 3 a, 13.8 in. 15.5 in. Diirnensii ns Width I Height Depth V 10.8 in. 1 120 Phase Electrical 60 <20 1 QO 100 60 <20 60 i00 60 <20 60 1 70 u D EA L CHEMICAL SYSTEM AT 3 -COMP SINE SCALE: NONE L1I 1 I PC PC MOP SINK (STANDARD - SOL1D SURFACE) MOP SINK (OPTIONAL ° STAINLESS STEEL) 1 /5 H FROM TOP IOF THE TANK 2234.015 MAD'. 'A EL L6 2305.100 MADERA EL 101,E MEI @ICAII STANDARD 63010010 WASfHIBIROOI{ WOODFORD 1'134 FIAT JUST ELKAY UN STRUT P -1 000T CHANNEL, BOLT TO WALL STRUCTURE 1RII Tip ( 2) 5/5" BOLTS, MIN. P1 45S BRACKET, (S) 1/2" BOLTS AND NUTS, TYPICAL OF 2 PLACES 2 "xI66A. GALV SoMo STRAP AA T R HEATERS PP I ' A 1I Cal F MODEL x ADVANCE TABCO J 7- PPS -26 V GENERAL CONTRACTOR 0124.1 31 COMRADE SEE KITCHEN DRAWINGS ITEM: 151.00 URE SCHEDULE ACCESSORIES /COMMENTS FLUSH VALVE, ANTI MICROBIAL OPEN FRONT SI A l LESS COVER, BOLT CAPS , A JTl- 1,9I ©ROS'IAL OPEN FRONT SEAL' LESS COVER, BOLT CAPS FLUSH VALVE, Soso STRAINER, TYPE II URINAL, CARRIER W/ CONCEALED ARMS AND TIE ROD FAUCET, NPS CHROME - PLATED COPPER WITH STOPS, GRID D11A1N, 1'¢p NPS CHROME-PLATED CAST -BRASS P°°Th 'P, A?DA COMPLIANTI PROTECTIVE SHIELOING GUARD FAUCET, : ° RIPS CHROME- PLATED COPPER WITH S` ?OPS, GRID ORAN, 13'}" NPS CHROME-PLATED CAST -BRASS P- TRAP, AI.DA COMPL9A[i1T PROTECTIVE SHIELDING GUARD, TYPE II LAVATORY CARRIER V' TPI CONCEALED ARMS AND TIE FW 23.6 in. 15.3 in. 6°o NICKEL - BRONZE FINISH STRAINER, 3'0 PIPE SIZE, 4 NICEEI - -UC OC+IZE FUNNEL 6"0 NICKEL - BRONZE FINISH STRAINER, 3'0' PIPE SIZE O" O NICKEL- BRONZIF. FINISH STRAINER, 4 "I4J PIKE SIZE, Osier OVAL FUNNEL 6 "Q NICd(EL7°BROPIZE EINISN1 STRAINER, 4 "0 PIPE, SIZE THICK MICKEL-BRONZE GRATE, 3'0 PIPE SIZE, ALUMINUM 1 DOME STRAINER FAUCET, GRID WITH r PWS ourri T AND Pg -`SAP FAUCET. GRID WITH R S OUTLET AND P -TRAP 24 ° Ei24 "x4�'1N, FAUCET,. S.S. STRAINER, 4" NPS OUTLET, Soso GRATE FAUCET SUPPLED WITH SINK, r " 61PS CHROME- PLATED COPPER WITH STOPS, GRID DM IN, 1,R ` 61PS CHROME- PLATED CAST-BRASS P -TRAP, ADA COMPLIANT PROTECTIVE SHIELDING GUARD, TYPE III CARRIER r % HANGER AND BEARING PLATES AND TIE ROD FAUCET AND BASKET DRAIN SUPPLIED WITH SINK, 132" NPS Clr ROME -PLAT Lvf' CAST- BRASS P- TRAP OR INDIRECT DRAIN; e HERS CHROME -PLATED COPPER WITH STOPS FAUCET AND BASKET DRAIN SUPPLIED WITH SINK, 1�,' NPS CHROME - PLATED CAST-BRASS P -TRAP OR INDIRECT (DRAIN, iz" NPS CHROME -FATED COPPER WITH STOPS ALL VALVE STOP M TH THREADED END, ONE (1) , ,T PISTON TYPE HAMMER ARRESTOR, 101 INDIRECT (DRAIN BOX, TWO (2) Y" PISTON TYPE HAMbIER ARRESTORS 27. 75 120 -�- 20 r- 120 ,I 4.5 in. GO Eiectrical Hz I FaLi. . 60 60 <20 60 --- -._.0. 150 71 60 1 6000 150 60 <20 60 .-_- 150 <20 100 1 . RECEIVED CITY OF TUKVUMIA SEP 112008 PERMIT CENTER 2Li