HomeMy WebLinkAboutPermit M09-007 - THALES AVIONICSTRACES AVIONICS
2811 S 120 ST
M09 -007
Parcel No.: 0423049190
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
doc: IMC -10/06
2811 S 102 ST TUKW
Citylif Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
THALES AVIONICS
2811 S 102 ST , TUKWILA WA
Contact Person:
Name: CHRIS LEE
Address: 7717 DETROIT AVE SW , SEATTLE WA
Contractor:
Name: MACDONALD /MILLER FAC SOL INC
Address: PO BOX 47983 , SEATTLE, WA
Contractor License No: MACDOFS980RU
Value of Mechanical: $5,290.00
Type of Fire Protection:
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat /Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
MECHANICAL PERMIT
SABEY CORPORATION
12201 TUKWILA INTERN'L BLVD , FOURTH FLOOR
DESCRIPTION OF WORK:
INSTALL 8 DIFFUSERS, INSTALL 2 RETURN GRILLS, RELOCATE 5 DIFFUSERS, RELOCATE 3
RETURN GRILLS, INSTALL 1 CEILING MOUNTED EXHAUST WITH ROOF ROOF CAP FOR TOILET
ROOMS AND MISCELLANEOUS DUCTWORK PER PLANS
EQUIPMENT TYPE AND QUANTITY
0
0
0
0
0
0
0
0
0
0
1
0
0
0
* *continued on next page **
M09 -007
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 206 -768 -4266
Phone: 206 - 768 -4180
Expiration Date: 12/31/2010
M09 -007
01/27/2009
07/26/2009
Fees Collected: $242.81
International Mechanical Code Edition: 2006
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 18
Thermostat 0
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment
Printed: 01 -27 -2009
Permit Center Authorized Signature:
I hereby certify that I have read and e
governing this work will be complied
doc: IMC -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206- 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
lP
•
Permit Number: MO9 -007
Issue Date: 01/27/2009
Permit Expires On: 07/26/2009
Date: 0 L
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance f work. I am authorized to sign and obtain this mechanical permit.
Signature: , Date:
Print Name: A YaA l l
1 — Z7 -6 9
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
M09 -007 Printed: 01 -27 -2009
1: ** *BUILDING DEPARTMENT CONDITIONS * **
doc: Cond -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax:. 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Parcel No.: 0423049190 Permit Number: M09 -007
Address: 2811 S 102 ST TUKW Status: ISSUED
Suite No: Applied Date: 01/16/2009
Tenant: THALES AVIONICS Issue Date: 01/27/2009
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
* *continued on next page **
M09 -007 Printed: 01 -27 -2009
Signature:
Print Name:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
doc: Cond -10/06 M09 -007
O
�--2 ?- ci
Date:
ordinances governing
or local laws regulating
Printed: 01 -27 -2009
Tenant Name:
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.ci.tukwila.wa.us
W
TUKWILA
W
Building Permit No.
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use'only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
King Co Assessor's Tax No.: oci 3 O ¥ I 9 0
2 eo
❑ Yes M..No
Site Address: 2;51 1 1 S t l 2-16. -�f
ivenr-CYC) ` r-1- e.Ck 1 r'1 Ct. I{'.S Av I on I (S New Tenant:
Property Owners Name: S c�.M `,�
Mailing Address: 1 2 - 20 1 —. 1 - 0 kuo 1.0% ', 1 V . I) T k �,�• i I is A Mai
City State Zip
Suite Number:
Floor:
CONTACT PERSON
Name: CCh
Mailing Address: — 1 - 1 At/f. SJ
E -Mail Address: C e t S. Le_it ma.c„,, ,,` s C OM
GENERAL CONTRACTOR. INFORMATION --
(Contractor Infetmattan for Mechani (pg 4) for 1'luinbing and Gas Piping (pg 5) )
Company Name:
Mailing Address:
Contact Person:
E -Mail Address: Fax Number:
Contractor Registration Number: pition Date:
ARCHITECT OF RECORD —
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
ENGINEER OF RECORD - A .
stamped
Contact Person:
E -Mail Address:
o:4 6pplications\FOnns.Applications 6n Line \3.2006 - Permit Appiieation.dec
Revised' 4 -2006
Day TelephoneLZO .4) � 1 U ya b b
SQ_C .Re Lk) TR/ C•
ngine
City State Zip
Fax Number: ( L) 7 b 4d
City
State
Zip
Day Telephone:
plans must be wet stamped by Architect of Record
City
Day Telephone:
Fax Number:
plans' must' be we
e
0
Record
State
Zip
Company Name:
Mailing Address:
City
Day Telephone:
x Number:
s
tc
Zip
Page I of 6
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
j CI
3 -15 HP/500,000 BTU
Flour Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15-30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Chth"w�+ kikr,
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Water Heater
50 -I- HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig /Cooling
System
Incinerator - Domestic
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator — Comm/Ind
Other Mechanical
Equipment
MECHANICAL PERMIT INFORMATION - 206 - 431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name: AA tLC�Q IAA �\ i-
Mailing Address: 1\ 1"∎
Contact Person: - 1)(1- iC-L42 C.) p l
E -Mail Address:
Contractor Registration Number: 4C,, 0e S 9 %o g.4)
Valuation of Project (contractor's bid price): $ S / Z' O
Scope of Work (please provide detailed information): I
C2 - 11 cr // re'. I r
r
r f C
Use: Residential:
Commercial:
Fuel Type: Electric
New ... ❑
New ...
Q: Appiications\Fomts•Applieations On Line13 -2006 - Permit Application d e
Revised: 4 -2006
bh
Replacement .... ❑
Replacement .... ❑
SW
ac4t-ti
wA 9710
State zip
city
Day Telephone: (ZOt,) -JOS' - (- 19.95‹
Fax Number:
Expiration Date:
c t t w,a + ice — 1 - nS'1`,a / / c
c� t E U .-V..J / / ." c.. r
CQ 1 t 9 tvuo -u n
its it a-� t Ii r ry S . CA-14
Gas ....0 Other:
Indicate type of mechanical work being installed and the quantity below:
Page 4 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING Ott • • AUTHORIZED AGEN
Signature: v — —
Print Name: t
Mailing Address: + l \ — I Q., tr l 1 ALw-R, SL,)
Day Telephone:
Q0C
City
Date: 4•— 0 c \
t.d044 9 1toc,
State Zip
Date Application Accepted:
Date Application Expires:
Staff Initials:
we I
Q: Upplications \Forrns- Applications On Line 3.2006 - Permit Applicatimrdon
Revised: 4-2006
bh
Page 6 of 6
Parcel No.: 0423049190 Permit Number: M09 -007
Address: 2811 S 102 ST TUKW Status: PENDING
Suite No: Applied Date: 01/16/2009
Applicant: THALES AVIONICS Issue Date:
Receipt No.:
R09 -00088
Initials: WER Payment Date: 01/16/2009 10:00 AM
User ID: 1655 " Balance: $0.00
Payee: MACDONALD MILLER
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 2003 242.81
ACCOUNT ITEM LIST:
Description
MECHANICAL -. NONRES
PLAN CHECK - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax:' 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Account Code Current Pmts
000.322.102.00.0 194.25
000/345.830 48.56
Total: $242.81
Payment Amount: $242.81
1571 01/16 9707 TOTAL 334.81
doc: Receiot -06 Printed: 01 -16 -2009
Project:
7 /F5
Type of Ijpection:
/-/Ai 49 I
Addres
Date Called:
Special Instructions:
Date Wanted:
.
Requester:
Phone No:
G - . .7,/
— 3/ 7 3
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
/278 -4U
PERMIT NO.
1'7"•
(206)431 -3670
Approved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
anvele
f !D- - 7 - 47 7
El $60.' I INSPECTION FEE Rth UIR D. Prior to inspection, fee must be
pai - • • 300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receip 'o.: !Date:
Project:
/14,6
-
/ J��`
<
Type of In ectio
AiN f - i s \i
A.e LL
12
..` Date
Called:
Special Instructions:
Date
+. Wanted:
�•'
Requester:
Phone No:
INSPECTION RECORD
' a copy with permit
INS PECTION NO. PERMIT NO. /
CITY OF TUKWILA BUILDING DIVISION t �
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 -3: 70
A pproved per applicable codes. El Corrections required prior to approval.
COMMENTS:
El $60. ' EINSPECfi10N FEE REQ
pai 6300 Southcenter Blvd., Sul
ED.
e 1
Date: --
Z M 3-
' rior to inspection, fee must be
. Call to schedule reinspection.
Receipt 7o.: 'Date:
COMMENTS:
Type nspection:
Address:
del( S 102��
Date Called:
,
Date Wanted:
1_,, SD
J - , 4 ? , ) 4 - C Ale -- l J
4)14-
T
6- '
g
,00
TJoT G'0, +1tf tau0 U. /3
r.
Op vt- C u&11 f:,'rc J ?r,v id
f ' elr
' r � - 1
1 i
Pr ect:
Type nspection:
Address:
del( S 102��
Date Called:
Special Instructions:
Date Wanted:
Requester:
Phone No:
-2-0(.0-5
71 3 1 .-- 7'
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter `Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes.
(Inspect
INSPECTION RECORD
Retain a copy with permit
maq -do
PERMIT NO.
Corrections required prior to approval.
rl $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
Thales Avionics
V e0 GC91
C?a
•
TAE
Location
Building owner
Program user
Company
Comments
By
Dataset name
Calculation time
TRACE® 700 version
Location
Latitude
Longitude
Time Zone
Elevation
Barometric pressure
Air density
Air specific heat
Density- specific heat product
Latent heat factor
Enthalpy factor
Summer design dry bulb
Summer design wet bulb
Winter design dry bulb
Summer clearness number
Winter clearness number
Summer ground_ reflectance
Winter ground reflectance
Carbon Dioxide Level
Design simulation period
Cooling load methodology
Heating load methodology
NO9 ocri
2811 S 102nd St, Tukwila, WA 98168
Chris Lee
MacDonald Miller Facility Solutions
2nd floor office expansion
MacDonald - Miller
C:ICDSITRACE7001Projects1729 -5011 Thales AvionicslTHA
05:05 PM on 01/13/2009
6.1.3
Seattle, Washington
47.0 deg
122.0 deg
8
386
29.5
0.0749
0.2444
1.0988
4,836.9
4.4953
83
67
24
0.95
0.95
0.20
0.20
400
ft
in. Hg
lb/cu ft
Btu /Ib• °F
Btu /h•cfm °F
Btu•min /h
lb•min /hrc
°F
°F
°F
ppm
January - December
CLTD -CLF (ASHRAE TFM1
UATD
nos Lt a 4O
JAN 23
t14��
RECEIVED
JAN 16 2009
PERMIT CENTEF
TRACE700
compnfrenJe ewnInu •nays"
aoftwan from Trans
VAV
Envelope Loads
Skylite Solar
Skylite Cond
Roof Cond
Glass Solar
Glass Cond
Wall Cond
Partition
Exposed Floor
Infiltration
Sub Total = =>
Internal Loads
Lights
People
Misc
Sub Total = =>
Ceiling Load
Ventilation Load
Adj Air Trans Heat
Dehumid. Ov Sizing
Ov /Undr Sizing
Exhaust Heat
Sup. Fan Heat
Ret. Fan Heat
Duct Heat Pkup
Reheat at Design
Grand Total =_>
COOLING COIL PEAK
Peaked at Time: Mo /Hr: 7 / 17
Outside Air: OADB/WB /HR: 81 / 65 / 67
Space
Sens. + Lat.
Btu /h
Plenum
Sens. + Lat
Btu /h
0 0 0
0 0 0
0 -102 -102
5,087 0 5,087
485 0 485
1,139 1,290 2,429
0 0
0 0
0 0
6,710 1,188 7,897
1,016 -1,016 0
0 0 6,418
0 0
0
0 0
- 490 -490
2,026
0 0
0 0
0
38,040 1,486 47,971
Net Percent
Total Of Total
Btu /h ( %)
0
0
0
11
1
5
0
0
0
16
7,222 1,806 9,027
9,160 9,160
13,932 0 13,932
30,314 1,806 32,120 67
19
19
29
0
13
0
0
0
-1
4
0
0
0
100.00
CLG SPACE PEAK
Mo /Hr: 7 / 17
OADB: 81
Space
Sensible
Btu /h
0 0
0 0
0 0
5,087 15
485 1
1,139 3
0 0
0 0
0 0
6,710 20
7,222
4,921
13,932
26,075 77
1,016
0
0
0
Percent
Of Total
( %)
21
15
41
3
0
0
0
33,801 100.00
Envelope Loads
Skylite Solar
Skylite Cond
Roof Cond
Glass Solar
Glass Cond
Wall Cond
Partition
Exposed Floor
Infiltration
Sub Total = =>
Internal Loads
Lights
People
Misc
Sub Total = =>
Ceiling Load
Ventilation Load
Adj Air Trans Heat
Ov /Undr Sizing
Exhaust Heat
OA Preheat Diff.
RA Preheat Diff.
Additional Reheat
Grand Total = =>
HEATING COIL PEAK
Mo /Hr: Heating Design
OADB: 24
Space Peak
Space Sens
Btu /h
0
0
0
0
-3,420
-1,101
0
0
-2,350
-6,871
0
0
-1,395
-1,395
-2,601
0
0
0
- 10,867
Coil Peak Percent
Tot Sens Of Total
Btu /h ( %)
0
-6,598
0
-3,420
-2,301
0
0
-2,350
- 14,669 40.64
0
0
-1,395
-1,395
0 0.00
0.00
18.28
0.00
9.47
6.37
0.00
0.00
6.51
0.00
0.00
3.86
3.86
0 0.00
- 21,427 59.36
0 0
0 0.00
1,393 -3.86
0 0.00
0 0.00
0 0.00
- 36,098 100.00
Main Clg
Aux Clg
Opt Vent
Total 4.0
Total Capacity
ton MBh
4.0
0.0
0.0
48.0
0.0
0.0
48.0
COOLING COIL SELECTION
Sens Cap. Coil Airflow Enter DB/WB/HR
MBh cfm °F °F gr /Ib
41.1
0.0
0.0
1,709.0 75.8 61.6 60.6
- 0.0 - 0.0 0.0 0.0
Leave DB/WB/HR
°F °F gr/lb
53.9 51.8 54.8
0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0
Project Name: Thales Avionics
Dataset Name: C: \CDS \TRACE700 \Projects \729 -5011 Thales Avionics \THALES.TRC
System Checksums
AREAS
Gross Total Glass
Floor 3,047
Part 0
ExFlr
Roof
Wall
ft ( %)
0
3,047 0 0
612 143 23
Series Fan - Powered VAV
SADB
Plenum
Return
Ret/OA
Fn MtrTD
Fn BIdTD
Fn Frict
TEMPERATURES
Cooling
55.0
74.1
74.1
75.8
0.1
0.2
0.7
Heating
75.8
67.3
67.3
24.0
0.0
0.0
0.0
Vent
Infil
Supply
MinStop/Rh
Return
Exhaust
Rm Exh
Auxiliary
AIRFLOWS
Cooling
424
0
1,709
424
1,709
424
0
0
Heating
424
47
1,709
424
470
470
0
0
ENGINEERING CKS
Cooling Heating
% OA 24.8 24.8
cfm /ft=
cfm /ton
0.56 0.56
427.50
ft= /ton 762.22
Btu /hrft 15.74 -11.85
No. People
21
HEATING COIL SELECTION
CapacityCoil Airflow Ent Lvg
MBh cfm °F °F
Main Htg -22.2 1,709.0 .64.0 75.8
Aux Htg 0.0 0 0 0
Preheat -13.9 424 24 54
Humidif 0.0 0 0.0 0.0
Opt Vent 0.0 0 0.0 0.0
Total -36.1
TRACE® 700 v6.1.3 calculated at 05:05 PM on 01/13/2009
Alternative - 1 System Checksums Report Page 1 of 1
Load / Airflow Summary
By MacDonald - Miller
Coil Coil Space VAV Main Coil Heating
Floor Cooling Cooling Design Air Minimum Heating Fan
Area People Sensible Total Max SA Changes SA Sensible Max SA
System Zone Room ** ft # Btu /h Btu /h cfm ach/hr cfm Btu /h cfm
Aiteiiiattire 1 , e:
2047 Office int Rm Peak 152 1.0 1,635 2,057 69
2048 Office int Rm Peak 145 1.0 1,603 2,026 68
2049 Office int Rm Peak 160 1.0 1,672 2,094 71
2050 Office int Rm Peak 145 1.0 1,603 2,026 68
2051 Office per Rm Peak 279 2.0 6,401 7,051 257
2052 Office per Rm Peak 279 2.0 7,424 8,074 306
2053A Open office int Rm Peak 931 6.5 10,225 12,976 430
2053B Open office int Rm Peak 956 6.7 10,500 13,324 441
VAV Sys Peak 3,047 21.2 38,665 47,230 1,709
VAV Sys Block 3,047 21.2 41,081 47,971 1,709
**This report does not display heating only systems.
Project Name:
Dataset Name:
2.73
2.80
2.66
2.80
5.52
6.57
2.77
2.77
20
20
20
20
40
40
130
134
-629
-618
- 641
- 618
-5,450
- 6,134
-3,983
- 4,090
- 22,161
- 22,161
49
48
51
48
217
266
300
308
1,285
1,285
28.9
29.6
28.2
29.6
15.6
13.1
30.3
30.3
24.8
24.8
Percent
OA
ASHRAE
Std 62
Htg OA Fraction
28.9
29.6
28.2
29.6
15.6
13.1
30.3
30.3
24.8
24.8
Thales Avionics TRACE® 700 v6.1.3 calculated at 05 :05 PM on 01/13/2009
C: \CDS \TRACE700 \Projects \729 -5011 Thales Avionics \THALES.TRC Load /Airflow Summary Report Page 1 of 1
Project Name:
Dataset Name:
Location:
Building Owner:
Program User:
Company:
Comments:
Cooling Design Period:
Peak Hour Override:
Daylight Savings Period:
Summer Period:
Cooling Methodology:
Heating Methodology:
Infiltration Methodology:
Outside Film Methodology:
Terrain Methodology:
Room Circ Rate:
Wall Load To Plenum:
Building Orientation:
Simulation Hours:
Calendar Code:
Energy Simulation Period:
Entered Values
TRACE® 700 version 6.1.3
By MacDonald - Miller
Thales Avionics
C: \CDS \TRACE700 \Projects \729 -5011 Thales Avionics \THALES.TRC
2811 S 102nd St, Tukwila, WA 98168
Chris Lee
MacDonald Miller Facility Solutions
2nd floor office expansion
January thru December
0
CLTD -CLF (ASHRAE TFM)
UATD
Vary with wind speed
Vary with wind speed
Center of a large city
Medium
YES
135 degrees from north
Reduced year
Standard (1978)
January thru December
Location:
Summer Design Dry Bulb:
Summer Design Wet Bulb:
Winter Design Dry Bulb:
Summer Clearness Number:
Winter Clearness Number:
Summer Ground Reflectance:
Winter Ground Reflectance:
Carbon Dioxide Level:
Force VAV Min => Nominal Ventilation at Design:
Allow Energy Recovery/Transfer at Design:
Retest Design Peaks:
Calculate Building Block Loads:
Seattle, Washington
83.00 °F
67.00 °F
24.00 °F
0.95
0.95
0.20
0.20
400 ppm
No
No
Yes
No
Project Name: Thales Avionics TRACE® 700 v6.1.3
Dataset Name: C: \CDS \TRACE700 \Projects \729 -5011 Thales Avionics \THALES.TRC
Entered Values - Project Information
ACTIVITY NUMBER: M09 -007 DATE: 01 -16 -09
PROJECT NAME: THALES AVIONICS
SITE ADDRESS: 2811 S 102 ST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Build ng Di vision
Public Works
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS RO TING:
Please Route Structural Review Required
APPROVALS OR CORRECTIONS:
Documents /routing slip.doc
2 -28 -02
woluC ''.
PLAN REVIEW /ROUTING SLIP
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS:
Fir , 1.22-01
Structural
Incomplete
Planning Division
Permit Coordinator
DUE DATE: 01 -20-09
Not Applicable
No further Review Required
REVIEWER'S INITIALS: DATE:
DUE DATE: 02 -17 -09
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Name
Role
Effective Date
Expiration Date
HACK, RICHARD R
AGENT
01 /06/2003
SIGMUND, FRED J
PRESIDENT
01/06/2003
KOPET, TYLER C
SECRETARY
01/06/2003
KOPET, TYLER C
TREASURER
01/06/2003
LOVELY, STEVE C
VICE PRESIDENT
01/06/2003
Untitled Page
•
I
Page 1 of 2
Electrical Contractor
A business licensed by LW to contract electrical work within the scope of its specialty.
Electrical Contractors must maintain a surety bond or assignment of savings account.
They also must have a designated Electrical Administrator or Master Electrician who is a
member of the firm or a full -time supervisory employee.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent
Company
MACDONALD MILLER FAC
SOL INC
2067639400
PO BOX 47983
SEATTLE
WA
98106
KING
CORPORATION
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Previous License
Next License
Associated
License
Specialty 1
Specialty 2
602254260
ACTIVE
MACDOMF972BF
ELECTRICAL
CONTRACTOR
1/6/2003
1/6/2011
ENCOMMS981 JP
MCGIVMH979N8
GENERAL
UNUSED
MASTER ELECTRICIAN INFORMATION
License MCGIVMH979N8
Name MCGIVERN, MICHAEL H
Status ACTIVE
Business Owner Information
https: // fortress .wa.gov /lni/bbip/Detail. aspx ?License= MACDOMF972BF
01/27/2009
0 0)
O
N
)10
REFRIGERANT LINE
DN TO 1ST FLOO
IN EXISTING CONDUI
(7/8" SUC, 3/8" LIQ
EXHAUST ROOFCAP�
EXHAUST ROOFCAP
FXI ROOFCAP-
2
V 1
IX el)
COQ t E
le
j'3
VW-
RECEIVED
JAN 16 2000
PERMIT CENTER
8
1 -0
)7
ENGINEER:
0
0
z
f = u")
w C
t "` [ co
I i c f) 0) LT)
Et W Q
am'
r
I c I-•
C LEE
SHEET NUMBER:
I I I I I I I I
I I I I I I I I
1 1 1 1 1 1 1<
1111-1111-411,44
0
H-
w
w
8
a
n
LH
CO
GC
dll 'Ili + "ai)
TM2.03
W
a
z
F-
0
L.L
F-
Z
0
0
0 '
U-
0
W
LAST REVISED:
01 -14-09
CHECKED BY: DATE PLOTTED:
B GEZON 01-14-09
CAD: ISSUE DATE:
C LEE 01-14-09
DRAWING NUMBER:
D-0789-7295011-00
6
0 0)
O
N
)10
REFRIGERANT LINE
DN TO 1ST FLOO
IN EXISTING CONDUI
(7/8" SUC, 3/8" LIQ
EXHAUST ROOFCAP�
EXHAUST ROOFCAP
FXI ROOFCAP-
2
V 1
IX el)
COQ t E
le
j'3
VW-
RECEIVED
JAN 16 2000
PERMIT CENTER
8
1 -0
)7
ENGINEER:
0
0
z
f = u")
w C
t "` [ co
I i c f) 0) LT)
Et W Q
am'
r
I c I-•
C LEE
SHEET NUMBER:
I I I I I I I I
I I I I I I I I
1 1 1 1 1 1 1<
1111-1111-411,44
0
H-
w
w
8
a
n
LH
CO
GC
dll 'Ili + "ai)
TM2.03
W
a
z
F-
0
L.L
F-
Z
0
0
0 '
U-
0
W
LAST REVISED:
01 -14-09
CHECKED BY: DATE PLOTTED:
B GEZON 01-14-09
CAD: ISSUE DATE:
C LEE 01-14-09
DRAWING NUMBER:
D-0789-7295011-00
„F
N
0
N
E
a)
0
0
N
0
C
0
a
a)
7
—_s
VAV -152
VAV -2.100
CAP
V
8x8 `•
siuu
L' 1 CAP
VAV
VW 20
.... " . rte V A
EF -20'1;
AIR 6
VAV
VAV—
)
P 2) ' �J
FRICTION! DA 1
/ — ('O 4)
T2.._.R OFD
1
1! , 4. . �..
IkeE
MOST RA,
fi A,
VAV - 6 '1
VAV- 2.10;
VAV 20 7.,.,
x10
.P. `2
R/A RILES HIGH
ABV E ROPPED C :il
PAINT WALL COLQIJ6
_ MOUNt W/ BLADE'
, (TYP 1)
E t 11 st
1444/ OI I F CTOR
Lfa
VAV -2.104
P
GIRECTOI
12o [ )4K
VAV -259
VAV - 2.20 C6
x8
1 0
U
r
f
CJs 1""f
TVAV-25I
i
AREA OF WORK
(2 58)
GENERAL NOTES
A
6x D
� - ` yu
1. VAV NUMBER DESIGNATION:
1ST DIGIT = FLOOR NUMBER
2ND DIGIT = MEDIUM PRESSURE BRANCH NUMBER
3RD THRU 5TH DIGITS = VAV BOX IDENTIFIER
100,1,.\-%'
r
L Of.:{EY
(2000)
s
0 D D
7
LOBBY
I o��al
RECEIVED
JAN 1 2909
PERMIT CENTEh
1 /8”
rr
0
E-
0 < co
co
I-- co
Z
N la
ENGINEER:
C LEE
CHECKED BY:
B GEZON
CAD:
C LEE
SHEET NUMBER:
I I I I I I I I
I I I I I I 181 W
0
I I I I I I l<
1.::ni:
c
cc
W
0
TM2.02
DRAWING NUMBER:
D-0789-7295011-00
LAST REVISED:
01 — 14 - 09
DATE PLOTTED:
01 — 14 - 09
ISSUE DATE:
01-14-09
cn
0
0
0 1
E
0
N
N
+-•
_c
0
cn
cn
0
0
0
In
N
N
0_
N
0
10
10
0)
0
0
N
CITY OF TUKWILA
ZONING MIC/H
ROOF CAP
PARCEL
#0423049190
82'-5"
NE BUILDING ELEVATION
SCALE: Or 1
CITY OF TUKWILA
ZONING MIC/H
AREA OF WORK
CITY OF TUKWILA
ZONING MIC/H
f
EXHAUST
S ROOFCAP
____. By
I
77'
I
EXISTING
GRADE
CITY OF TUKWILA
ZONING MIC/H
CITY OF SEATTLE
ZONING R-6
egior ca) run.
COTT COMP .•-,i1C'E
V41E1)
10 23 211
MOM ila
13 UM 9t1J5.3M
RECEIVED
JAN 1 2009
HERMIT CENTEf-,
1/64" = V-0"
1 1
z
o
w 0
- z
H O
o
Et
u (1)
cL 11-12
ENGINEER:
C LEE
CHECKED BY:
B GEZON
CAD:
C LEE
SHEET NUMBER:
CD CO
N-
CO CO
CD
<
C.0
ai 0
a) a l
(O
a) c,
7
c
> CO
<
E. (A
C\I
CI) -
• c
0
• .z
a_
1 1111111
(7)
E
E
I I I 21 LiJ
0
UJ
LAST REVISED:
DATE PLOTTED:
DRAWING NUMBER:
D-0789-7295011-00
TM0.01 S
z
0
F—
z
0
0
0
w
(i)
01-14-09
01-14-09
ISSUE DATE:
0 1 - 1 4 - 0 9
0
0
v
c
a�
L ECTRICAL CONTRACTOR
BY ELECTRICAL CONTRACTOR.
NOTES
14/12 C
14/12
14/ 12e-W
14/12 DB
1 12
NEW UNIT OLD UNIT
NO. NO. MFG & MODEL NO,
VAV -1.201
VAV -1.202
VAV -1.203
VAV -1.204
VAV -1.205
VAV-1.206
VAV -1.207
-
VAV -1.301
VAV-1.302
VAV -1.303
VAV -1.401
VAV -1.501
VAV - 1.601
VAV -1.602
VAV -1.603 60
VAV-1.604
VAV -1.605
VAV- 1.701
VAV -1.702
VAV - 1.703
VAV -1.704
VAV -1.705
VAV -1.706
VAV -1.707
VAV -1.801
VAV -1.802
VAV- 1.803
VAV -2.100
VAV -2.101
VAV -2.102
VAV -2,103
VAV -2.104
VAV -2.200
VAV -2.201
VAV -2,202
VAV-2.203
VAV -2.204
VAV -2.205
VAV -2.206
VAV -2.207
VAV -2.299
VAV -610
VAV -261
VAV -104
VAV -205
VAV -207
VAV 209
VAV -210
VAV -155
VAV-609
VAV -303
VAV -602
VAV -506
VAV-603
VAV -164
VAV -802
N/A
N/A
TRANE VSEE -2420
TRANE VSEE -0607
N/A
6
VAV- 07 TRANE VSEE -2420
VAV -302 TRANE VSEE -2420
VAV -401 TRANE VSEE -2420
VAV -402 TRANE VSEE -2420
VAV -608 N/A
VAV -154 N/A
VAV -505 TRANE VSEE -1715
VAV -707 TRANE VSEE -1715
VAV -708 TRANE VSEE -1715
VAV -156 N/A
VAV -803 N/A
VAV -262 N/A
VAV -152 N/A
VAV -153 N/A
VAV -157 N/A
VAV -161 N/A 6
VAV -254 TRANE VSEE -1111 8
VAV -253 N/A
VAV -255 N/A 12
VAV -163 N/A 10
VAV -201 TRANE VSEE -2420 12
VAV -257 TRANE VSEE -1715 10
VAV -258 N/A 12
VAV -259 TRANE VSEE -1111 8
VAV -260 TRANE VSEE -0607 6
VAV -252 N/A 8
NOTES:
1. LABEL VAV BOXES WITH NEW NUMBERS,
2, POWER WIRING AND DISCONNECT SWITCH BY ELECTRICAL CONTR
FIEL D V 1
3 CONTROLLED BY ECON EXISTING S OF'1 DDC NEATER. SYSTEM
111111 s 1 19 91111 1
4 D
C� N ATER E 11 11 P TED .
5. ERIFY MF ,, MO ELAN
111 I1I I
UNIT
NO.
EF -101
EF -201
EF -202
EF -203
SYSTEM SERVED
AREA SERVED
BR RM /HYDRAULICS
PREP ROOM
BREAK ROOM
TOILET RM
OFFICE 2031
OFFICE 2024
TRANE VSEE -2420
TRANE VSEE -1715
TRANE VSEE-1715
TRANE VSEE -1715
N/A
TRANE VSEE -1715
N/A
N/A
N/A
N/A
INLET FAN VALVE CFM
SIZE CFM MAX MIN
10 630 630 190
7 420 420 130
6
250 250 80
12 1220 1220 370
10 860 860 260
10 865 865 260
10 1300 1300 390
10 560 560 170
10 805 525 160
6 245 245 70
8 530 530 160
10 905
12 1085
6 520
8 460
12 1750
12 1315
12 2265
12 2000
6 320
6 340 340 100
12 765 765 230
8 - - -- 500 - -_ - -_ - 500 150
WARREN CBK
WARREN CBK
M FG & MODEL NO.
GREENHECK BCF -112
GREENHECK SP -A190
GREENHECK SP -A390
BROAN L400L
N
11�
1 D I 1 S I CONNEC Tu Y ELECTRI CONTRACTOR.
2, MO TOR STA 0°
4.
N:1 CONT
3. P R O V I DE SPEED II I O NT R OL' I WITH FAN.
4. IN T I E R LOCK I O 1 II I ,E R A TIO N ITH TOILE ROOM LIGHT SW IT CH.
III
390 390 120
640 640 190
660 660 200
1600 1600 480
480 440 210
840 840 200
690 690 100
630
760
480
1100
1250
900
9040
900
440
460
340
905 270
1085 330
520 160
460 140
1400 420
1220 420
1210 360
1075 320
320 100
630
760
440
1000
1250
900
950
900
440
460
310
190
160_
210
330
1250
240
210
270
110
140
150
VOLT /PH SIZE W" x H"
115/1 8 "x8"
115/1 8 "x8"
HEATER
KW DT CFM VOLT/PH STGS
10 { 26 1220 277/1 2
5.5 20 860 277/1 1
8 29 865 277/1 2
8 19 1300 277/1 2
805 277/1
29 1085 277/1
18 520 277/1
10 18 1750 277/1
10 24 1315 277/1
2265 277/1
2000 277/1
5.5 27 _ 640 277/1
5.5 26 660 277/1
5.5 11 1600 277/1
CFM
210
120
NOTES:
1. DISCONNECT BY EC. l 1 111 1 11 I I 1
11 I H AUTO HIGH 2. PROVIDE WITH: 2-STAGE, CONTROL TRANSFORMER, {�IRFL,Q IIV , I 1 I ITC , AU O H GH . (MIT, MANUAL THERMO- DISC,
CONTACTORS, AND UL LISTING.
11
17 760 I 277/1
17 900 277/1 1
26 950 277/1 1
29 440 277/1
36 440
H 1 111 1 1
STEPS
2
1 1/3
1 -- 1/3
1 1/3
TYPE CFM ESP RPM HP VOLT /PH BDD
IN LINE
2100 0.7 953 1 460/3
150 0.2 1254 113W 115/1
CEILING Y
CEILING 280 0.2 1063 135W 115/1 Y
IN -LINE 280 0.25 775 146W 120/1 Y
FAN
HP VOLT /PH
EXISTING, 2,3
1 1 /2 277/ EXISTING, 2,3
1/3 277/1 EXISTING, 2,3
1/3 277/1
EXISTING, 2,3
1/3 277/1 EXISTING, 2,3
EXISTING, 2,3
1/3 277/1 EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
1/2
1/2
1/2
1/2
1 1/3
277/1 1 1/8
EXISTING, 2,3
277/1 EXISTING, 2,3
277/1 EXISTING, 2,3
277/1 EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
REBAL,EXISTING, 1,2,3,5
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
1/3 27 EXISTING, 2,3
REBAL,EXISTING, 1,2,3,5
REBAL,EXISTING, 1,2,3,5
EXISTING, 2,3
1/2 277/1 EXISTING, 2,3,4
1/3 277/1 J EXISTING, 2,3
EXISTING, 2,3
CONTROL
24V
ECONDARY HIGH LIMIT
WT
LBS
350
15
21
41
277/1
277/1
277/1
277/1 -_. -__ _.
277/1
277/1
277/1
277/1
NOTES
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
EXISTING, 2,3
REBAL,EXISTING, 1,2,3,5
NOTES
EXISTING, 1,2
REBAL,EXISTING, 1,2
NOTES
EXISTING, 1,2
EXISTING, 1,3
EXISTING, 1,3
NEW, 1,3,4
ABBV FULL NAME
A COMPRESSED AIR LINE
AC
AFF
AL
BDD
BOB
BOD
BOTT
BTU
BTUH
BWG
BWR
C
CAP
CC
CFM
CHWR
CHWS
COMB
CONN
CWR
CWS
DB
DIFF
DMPR
DN
EC
EGC
EER
ELEV
EMS
AIR CONDITIONING UNIT
ABOVE FINISHED FLOOR
ALUMINUM
BACKDRAFT DAMPER
BOTTOM OF BEAM
BOTTOM OF DUCT
BOTTOM
BRITISH THERMAL UNITS
BRITISH THERMAL UNITS PER HOUR
BOTTOM WALL GRILLE
BOTTOM WALL REGISTER
CONDENSATE
CAPACITY
CONTROLS CONTRACTOR
CUBIC FEET PER MINUTE
CHILLED WATER RETURN
CHILLED WATER SUPPLY
COMBUSTION
CONNECT
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
DUCT BOARD
DIFFUSER
DAMPER
DOWN
ELECTRICAL CONTRACTOR
EGGCRATE
ENERGY EFFICIENCY RATIO
ELEVATION
ENERGY MANAGEMENT SYSTEM
ABBV FULL NAME
ESP
EXH
EXTR
FAG
FD
FLA
FOB
FOT
FSD
G
GALV
GC
GPM
GR
GWB
HG
HP
HWR
HWS
ID
INT
LIQ
M -M
MBH
MC
MCA
MD
MIN
MT
MUA
NOM
EXTERNAL STATIC PRESSURE
EXHAUST
EXTRACTOR
FIRE ALARM CONTRACTOR
FIRE DAMPER
FULL LOAD AMPS
FLAT ON BOTTOM
FLAT ON TOP
FIRE SMOKE DAMPER
GAS LINE
GALVANIZED
GENERAL CONTRACTOR
GALLONS PER MINUTE
GRILLE
GYPSUM WALL BOARD
HOT GAS LINE
HORSE POWER
HOT WATER RETURN
HOT WATER SUPPLY
INSIDE DIMENSION
INTERLOCK
LIQUID LINE
MACDONALD- MILLER
ONE THOUSAND BTUH
MECHANICAL CONTRACTOR
MINIMUM CIRCUIT AMPACITY
MOTORIZED DAMPER
MINIMUM
MOUNT
MAKE -UP AIR
NOMINAL
ABBV FULL NAME
OSA
OBD
OD
RA
REG
REQ'D
RIO
SA
SCD
SD
SL
SM
SP
SS
SSSC
STL
SUC
SUSP
T'STAT
TC
TOD
TOS
TV
TWG
TWR
TYP
UNO
VD
VFD
OUTSIDE AIR
OPPOSED BLADE DAMPER
OUTSIDE DIMENSION
RETURN AIR
REGISTER (GRILLE WITH DAMPER)
REQUIRED
ROUGH IN ONLY
SUPPLY AIR
SMOKE CONTROL DAMPER
SMOKE DAMPER
SOUND LINING
SHEET METAL
STATIC PRESSURE
START /STOP
SOLID STATE SPEED CONTROLLER
STEEL
SUCTION LINE
SUSPENDED
THERMOSTAT
TEMPERATURE CONTROL
TOP OF DUCT
TOP OF STEEL
TURN VANES
TOP WALL GRILLE
TOP WALL REGISTER
TYPICAL
UNLESS NOTED OTHERWISE
VOLUME DAMPER
VARIABLE FREQUENCY DRIVE
VOLTAGE PHASE & DUCT DIAMETER
:�.,
t .,- ,;;n!:;�� � :iiW ✓�✓�" , ✓ :,:: , :
: ✓✓ w�� ii(: 'r✓'il i .a., - c; dG x: RCv ^f' ✓��
, # .;
,,,,, ;:::: ,,✓✓� ii �� I ✓ , , h' i ,: i f � i � .. .may^ . x. � ,; i7 *+...6 fi�a ,:i I,
:,: ,,, ...rr ,+✓✓✓✓ � (i ��, , ,,,� r�.... .x;nh y: h > ,,., +. ,� . ,,,.. .'k:.. ✓, ... N
SYMBOL DESCRIPTION- POWERED NOTES SYMBOL DESCRIPTION -NON POWERED
1 1/2 HOUR FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL OR 1,2
HORIZONTAL, 3 -V BLADE,LEAKAGE CLASS 2, 120V ACTUATOR, 2 FD -1
POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK
FSD 212 OR EQUAL.
FSD- 1
FSD -2
FSD--3
FSD --4
FSD -5
FSD -6
MD --2
SCD -1
SMOKE CONTROL MOTORIZED DAMPER: MEDIUM VELOCITY
SCD -2 SC AIRFOIL BLADE, GREENHECK SMD 301 OR EQUAL.
NOTES:
1. ACTUATOR BY MECI IANISAL CONTRACTOR, WIRING BY
2. INTERLOCK OF SMOKE DAMPER TO FIRE ALARM SYSTEM
3. CONTROL FROM LOCAL DETECTOR
4. CONTROL FROM DUCT DETECTOR
5, GR /CLOSED POSITION INDICATOR
6. DAMPER FAILS ( OPEN
7. DAMPER FAILS CLOSED
DESCRIPTION
BARE SHEETMETAL
EXAMPLE OF DEMO
(EXAMPLE OF TI
EXISNG
1 1/2 HOUR FIRE /SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL
OR HORIZONTAL, AIRFOIL BLADE, LEAKAGE CLASS 2, 120V
ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK,
GREENHECK FSD 312 OR EQUAL.
3 HOUR FIRE /SMOKE DAMPER: LOW VELOCITY, VERTICAL OR
HORIZONTAL, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2
POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK
FSD 231 OR EQUAL.
3 HOUR FIRE /SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL
OR HORIZONTAL, AIR FOLD BLADE, LEAKAGE CLASS 1, 120V
ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK,
GREENHECK FSD 311 OR EQUAL,
1 1/2 HOUR TUNNEL CORRIDOR FIRE /SMOKE DAMPER:
LOW VELOCITY, 3V BLADE, LEAKAGE CLASS 2, 120V
ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK,
GREENHECK CFSD 212 -1 OR EQUAL.
1 1/2 HOUR OUT OF WALL FIRE /SMOKE DAMPER: LOW
VELOCITY, VERTICAL , 3V BLADE, LEAKAGE CLASS 2, 120V
ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK,
GREENHECK OF SD 212 OR EQUAL.
SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL.
SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL.
MOTORIZED CONTROL DAMPER -LOW VELOCITY GREENHECK
VCD -23 OR EQUAL.
MOTORIZED CONTROL DAMPER: MEDIUM VELOCITY AIRFOIL
BLADES GREENHECK VCD -33 OR EQUAL.
SMOKE CONTROL MOTORIZED DAMPER: LOW VELOCITY
GREENHECK SMD 202 OR EQUAL.
SOUNDLINE SHEETMETAL (1" LINING)
SHEETMETAL WRAPPED W/ INSULATION (2 ")
BARE ROUND SHEETMETAL
EXPOSED QUALITY SHEETMETAL
EXAMPLE OF NEW
114141.1,44..
r
SYMBOL DESCRIPTION
14/12
14/12 SL
14/12 W
120
14/12 Q
14/12
1 4/1 2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
3
4
1,2
1,2
FD -3
FD -4
FD- 5
FD -4
BAR
DUCTBOARD (1" FIBERGLASS)
FLEX DUCT
FLEX CONNECTOR
1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL
OR HORIZONTAL , 165° F FUSABLE LINK, BLADE IN AIR STREAM,
GREENHECK DFD 150 TYPE A OR EQUAL.
1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL
OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR
STREAM, GREENHECK DFD 150 TYPE B OR EQUAL.
3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL
OR HORIZONTAL, 165° F FUSABLE LINK, BLADE IN AIR
STREAM, GREENHECK DFD 350 TYPE A OR EQUAL.
3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL
OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR
STREAM, GREENHECK DFD 350 TYPE B OR EQUAL.
1
1 2 HOUR DYNAMIC FIRE DAMPER: LOW VELOCITY,
/
NARROWLINE, VERTICAL - FOR INSTALLATION BETWEEN 2
TRANSFER GRILLES IN A WALL ASSEMBLY, 165° F FUSABLE
LINK, GREENHECK DFD -110 OR EQUAL.
CEILING RADIATION DAMPER: GREENHECK CRD -2 OR EQUAL.
BACKDRAFT DAMPER: GREENHECK WD 330 (VERT) OR WD -100
BDD 4 (HORIZONTAL) OR EQUAL.
\\ BAROMETRIC RELIEF DAMPER: (.05 OPNG PRESSURE SHOWN)
RUSKIN CBD2. NO SUBSTITUTE ALLOWED.
VOLUME DAMPER: SHOP FABRICATED, W /LOCKING QUADRANT.
ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ")
CLEANROOM QUALITY DUCTWORK
BARE FLAT OVAL SHEETMETAL
FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ")
EXAMPLE OF NOT IN CONTRACT (NIC)
SYMBOL
120W
TYPE
T -BAR LAY -IN DIFFUSER
SURFACE MT DIFFUSER
SLOT DIFFUSER CLEAR SATIN ANODIZED FINISH
DOUBE DEFLECTION SUPPLY GRILLE
SURFACE MT RET /EXH GRILLE
SLOT RETURN
EXHAUST
RETURN
RETURN
NOTES
CLEAR SATIN ANODIZED FINISH
SYMBOL
SIZE
CFM
SIZE
CFM
SIZE
CFM
SIZE
CFM
SIZE
CFM
SIZE
CFM
SIZE
CFM
MANUFACTURER & MODEL NUMBER
SHOEMAKER 701 -MA
SHOEMAKER MA -DCF
TUTTLE AND BAILEY 7000
SHOEMAKER 904
SHOEMAKER 905 -DW
TUTTLE AND BAILEY 7000
M -M METAL EGGCRATE EXHAUST
M -M METAL EGGCRATE
M -M METAL EGGCRATE
SIZE
AS NOTED
AS NOTED
AS NOTED
AS NOTED
AS NOTED
AS NOTED
24/24
24/24
12/24
UNIT
NO.
EDH -201
EDH -202
144 r
NAME TITLE
TM0.01 SCHEDULES - HVAC
TM0.01 S SITE MAP - HVAC
TRANE VSEE SERIES FAN POWERED VAV BOXES
SERVES: OFFICE AREA
CONTROL TYPE: TEMPERATURE SENSOR
SETPOINTS: HEATING "ON" POINT: 70 °F, COOLING "ON" POINT: 75 °F
DDC SYSTEM INTERFACE: FULL CONTROL
SEQUENCE:
UNOCCUPIED MODE, HEATING: FAN TO RUN ON A CALL FOR HEATING. ELECTRIC HEATER TO OPERATE ON A CALL FOR HEATING.
AIR VALVE CLOSED TO MINIMUM POSITION
UNOCCUPIED MODE, COOLING: FAN TO RUN ON A CALL FOR COOLING. AIR VALVE TO MODULATE TO MAINTAIN SPACE TEMPERATURE.
UNOCCUPIED MODE, DEADBAND: FAN OFF. AIR VALVE CLOSED TO MINIMUM POSITION.
MORNING WARMUP MODE, HEATING: FAN TO RUN CONTINUOUSLY. ELECTRIC HEATER TO OPERATE ON A CALL FOR HEATING
AIR VALVE CLOSED TO MINIMUM POSITION
MORNING WARMUP MODE, COOLING: FAN TO RUN CONTINUOUSLY. AIR VALVE TO MODULATE TO MAINTAIN SPACE TEMPERATURE.
MORNING WARMUP MODE, DEADBAND: FAN TO RUN CONTINUOUSLY. AIR VALVE CLOSED TO MINIMUM POSITION
OCCUPIED MODE, HEATING: FAN TO RUN CONTINUOUSLY. ELECTRIC HEATER TO OPERATE ON A CALL FOR HEATING.
AIR VALVE CLOSED TO MINIMUM POSITION
OCCUPIED MODE, COOLING: FAN TQ RUN CONTINUOUSLY. AIR VALVE TO MODULATE TO MAINTAIN SPACE TEMPERATURE.
OCCUPIED MODE, DEADBAND: FAN TO RUN CONTINUOUSLY. AIR VALVE CLOSED TO MINIMUM POSITION.
NOTES: DDC CONTROL SYSTEM TO PROVIDE NIGHT SETBACK CAPABILITY AND SEVEN DIFFERENT DAY TYPES.
COOLING ONLY VAV BOXES
SERVES: OFFICE AREA
CONTROL TYPE: TEMPERATURE SENSOR
SETPOINTS: COOLING "ON" POINT: 75 °F
DDC SYSTEM INTERFACE: FULL CONTROL
SEQUENCE:
UNOCCUPIED MODE, COOLING: AIR VALVE TO MODULATE TO MAINTAIN SPACE TEMPERATURE.
UNOCCUPIED MODE, DEADBAND: AIR VALVE CLOSED TO MINIMUM POSITION.
MORNING WARMUP MODE, COOLING: AIR VALVE TO MODULATE TO MAINTAIN SPACE TEMPERATURE.
MORNING WARMUP MODE, DEADBAND: AIR VALVE CLOSED TO MINIMUM POSITION
OCCUPIED MODE, COOLING: AIR VALVE TO MODULATE TO MAINTAIN SPACE TEMPERATURE.
OCCUPIED MODE, DEADBAND: AIR VALVE CLOSED TO MINIMUM POSITION.
NOTES: DDC CONTROL SYSTEM TO PROVIDE NIGHT SETBACK CAPABILITY AND SEVEN DIFFERENT DAY TYPES.
EF -105
SERVES: RESTROOM AND KITCHEN
CONTROL TYPE: CONTINUOUS OPERTATION
SETPOINTS:
DDC SYSTEM INTERFACE: FULL CONTROL
SEQUENCE:
UNOCCUPIED MODE: FAN OFF
MORNING WARMUP: FAN OFF
OCCUPIED MODE: FAN ON.
NOTES: FAN EQUIPPED WITH SPEED CONTROL TO BALANCE TO PROPER AIRFLOW.
NAME TITLE
TM2.02 2ND FLOOR PARTIAL PLAN - HVAC
TM2.03 ROOF PARTIAL PLAN - HVAC
o
o�4
1. THE HVAC SYSTEM FOR THIS PROJECT IS BASED ON THE FOLLOWING CRITERIA:
ROOF "U" VALUE (BTUH /S.F. °F) = 0.05
WALL "U" VALUE (BTUH/S.F.°F) = 0.11
FLOOR "U" VALUE (BTUH /S.F. °F) = N/A
GLASS "U" VALUE (BTUH /S.F. °F) = 0.5
GLASS SHADE COEFF. = 0.55
LIGHTING (WATTS /S.F.) = 1.0
COOLING INDOOR DESIGN TEMP ( °F) = 75
COOLING OUTDOOR DESIGN TEMP ( °F) = 83
HEATING INDOOR DESIGN TEMP ( °F) = 70
HEATING OUTDOOR DESIGN TEMP ( °F) = 24
2. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER
TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK.
3. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING
CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES.
4. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA
AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM.
5, JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT.
6. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC.
- DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R -4.2 MIN.).
- SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.).
- DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R -4.3 MIN.',
7. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON- PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A
UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE.
8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2006 IBC.
9. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2006 IBC. PROVIDE CEILING
FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2006 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE /SMOKE
DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE.
10. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF
THE FLOOR OR WALL.
11. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN
ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR.
12. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS
SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18 ".
13. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE
POWER WIRING WITH ELECTRICAL CONTRACTOR.
14. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.
15. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS
SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM,
INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES.
16. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE
AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM.
17. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING
SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING.
18. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER
19. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR:
- ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC).
- TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC).
- ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ( "MONOCOAT ") IS NOT ACCEPTABLE (BY GC).
- ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION.
- USE SECTION 909.5 OF THE 2006 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION.
- ALL DOORS MUST BE PROVIEDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE.
20. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED
DAMPERS:10 CFM /S.F. GRAVITY DAMPERS: 20CFM /S,F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION).
21. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC.
22. RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.G. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL, DIFFERENTIAL PRESSURE IS BASED UPON
THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE.
23, PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS:
- SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE.
- SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1 -2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE.
- FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC PRESSURE, CONTACT MECHANICAL ENGINEER.
TITLE
PROJECT ENGINEER
ACCOUNT MANAGER
REFRIGERATION FOREMAN
AIR BALANCE FIELD FOREMAN
SHEET METAL FOREMAN
ELECTRICAL FOREMAN
DDC CONTROLS COORDINATOR
NAME
CHRIS LEE
REIS TIETGE
DEAN GRASSER
STEVE BAKER
ERIC JOHNSON
SAM VERT
SABRINA WORKMAN
COMPANY
MACDONALD MILLER
MACDONALD MILLER
MACDONALD MILLER
MACDONALD MILLER
MACDONALD MILLER
MACDONALD MILLER
MACDONALD MILLER
PHONE NUMBER
206-768-4266
206-768-4094
206 - 768 -4270
206 - 768 -3824
206 - 768 -4178
206- 407 -2638
206- 768 -4074
FAX NUMBER
206 -768 -4267
206 -768 -4095
206 - 768 -4271
206 -768 -3825
206 - 768 -4179
206 - 768 -4075
PROVIDE AND INSTALL (8) NEW DIFUSERS, (2) RETURN GRILLES, AND LOW FtlESSURE DUCT.
RELOCATE (5) DIFFUSERS AND (3) RETURN GRILLES.
RELOCATE (4) LOW VOLTAGE T- STATS.
INSTALL (1) EXHAUST FAN FOR THE NEW TOILET ROOMS AND TERMINATE THROUGH ROOF WITH A ROOFCAP.
AIR BALANCE (4) ZONES.
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
f'!'T : R3v'I ;fans will requiro a new plan submit!. I
r in !uct9 L dd:",IOnal p!ari rev;lw
APN # 0423049190
LEGAL DESCRIPTION: PORTION OF SE 1/4 - BEGIN SW CORNER OF GOV LOT 11 IN SE 1/4 OF SECTION 04 -23 -04 TH S 89 -22 -06 E 988.27 FT TH N 14 -45 -08 W 477.09 FT TO INTERSECTION WITH
N LINE OF S 460 FT OF GOV LOT 11 & NELY MARGIN OF PRIMARY STATE HIGHWAY NO 1 TH N 14 -45 -08 W 689.81 FT TO SWLY MARGIN OF 200 FOOT SEATTLE TRANSMISSION LINE TH N
14 -45 -08 W 22.70 FT TAP OF SPIRAL CURVATURE TH CONTINUING ALONG NELY MARGIN ALONG SPIRAL CURVE TO LEFT THE CHORD BEARING N 15 -07 -51 W 152.94 FT TAP OF SIMPLE
CURVATURE TH ALONG NE MARGIN NWLY 340.67 FT ALONG ARC OF NON TANGENT CURVE TO LEFT RADIUS OF 3970 FT RADIUS POINT BEARING S 74 -07 -22 W THRU C/A OF 04 -55 -00 TH
CONTINUING ALONG SAID NELY MARGIN N 11 -24 -57 E 327.11 FT TO POINT OF BEGINNING TH N 11 -24 -57 E 61.40 FT TAP OF SIMPLE CURVE TH CONTINUING ALONG SAID NELY MARGIN NWLY
191.94 FT ALONG ARC OF NON TANGENT CURVE TO LEFT RADIUS OF 4190 FT RADIUS POINT BEARING S 64 -42 -23 W THRU C/A OF 02 -37 -29 TH N 27 -01 -05 E 89.78 FT TH N 48 -11 -59 E 442.51 FT
TH S 41 -52 -02 E 881.11 FT TH S 48-
AREA OF WORK
VICINITY MAP
NO SCALE
SEPARATE PERMIT
REQUIRED FOR:
0 Mechanical
if Electrical
4 Pfumbing
�f Gas Piping
City of Tukwila
BUILDING DIVISION
RECEIVED
JAN 16 zoo
PERMIT CENTER
M09- 00
z
o
in
Z
H O
z
0
Et
t
� i � L J
w
Ct
ENGINEER:
C LEE
CAD:
C LEE
L
CD ,
cv
µINN(
0
I I I I I I I I
1 1 1 1 1 1 101
I
4
I I I I I I l<
Rill copy
cr i1
low CpprovaI b Cub} cct tD crro r c.:11
:' Cl C on trL c Cn Coin'!' ent3 C ac
Gt cny cdopt8rJ coda cr o d z7c 2.
vod F'fik1 Copy ad undone i C4C1','1Ctid si.; :-.1
6
City of Tukwila
CLELO NO DIVISION
0
■11 041
BMW
LAST REVISED:
CHECKED BY: DATE PLOTTED:
B GEZON 01-14-09
ISSUE DATE:
DRAWING NUMBER:
D- 0789 - 729501 1 - 00
SHEET NUMBER:
TM0.01
Ld
0
w
Q
0
z
0
F-
0
v!
z
0
0
0
U-
0
w
(f)
Vl
01 -14-09