Loading...
HomeMy WebLinkAboutPermit M09-010 - WILD WEST SHIRTWORKS - BUILDING BWI WEST SHIRTWORKS BLDG B 12626 INTERURBAN AV S Parcel No.: 0004800003 Address: Suite No: CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12626 INTERURBAN AV S TUKW Tenant: Name: WILD WEST SHIRTWORKS - BLDG B Address: 12626 INTERURBAN AVE S , TUKWILA WA Owner: Name: C/O EPROPERTYTAX INC Address: DEPT #207 , PO BOX 4900 Contact Person: Name: JOFFRE SECHIER Address: 6802 S 220 ST , KENT WA Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P -105 , KENT, WA Contractor License No: COMFOMI015LA MECHANICAL PERMIT DESCRIPTION OF WORK: REPLACE EXISTING 2 TON ROOFTOP PACKAGED A/C UNIT WITH NEW 2 TON UNIT W/ ECONOMIZER Value of Mechanical: $9,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM • Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10/06 EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** M09 -010 Permit Number: M09 -010 Issue Date: 02/13/2009 Permit Expires On: 08/12/2009 Phone: Phone: 425 - 251 -9840 Phone: 425 - 251 -9840 Expiration Date: 06/01/2010 Fees Collected: $279.11 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 02 -13 -2009 Permit Center Authorized Signature: I hereby certify that I have read and governing this work • e complied The granting of t • permit does not pres •. e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe rmanc of k. � am authorized to sign and obtain this mechanical permit. Signature: (A / %l�� � �' '�'�/' Date: g//3/ / Print Name: doc: I MC -10/06 • City of Tukwila Department of Community Development 6300'Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: MO9 -010 Issue Date: 02/13/2009 Permit Expires On: 08/12/2009 Date: 02- ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -010 Printed: 02 -13 -2009 Parcel No.: 0004800003 Address: Suite No: Tenant: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12626 INTERURBAN AV S TUKW WILD WEST SHIRTWORKS - BLDG B 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS * *continued on next page ** • Permit Number: Status: Applied Date: Issue Date: M09 -010 ISSUED 02/02/2009 02/13/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records,'and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. M09 -010 Printed: 02 -13 -2009 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the' performance of work. Signature: Print Name: i • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax:; 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us doc: Cond -10/06 M09 -010 • Date: a 7/3/D ordinances governing or local laws regulating Printed: 02 -13 -2009 Property Owners Nname: /fit Mailing Address: Po 6 Name: 1 Mailing Address: �4 E -Mail Address: JCS CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us W n \ s Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: E -Mail Address: City Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Mod -oia Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** k i - King Co Assessor's Tax No.: OKY ' 0 0 0 Site Address: `ako — av�- * e Suite Number: Floor: Tenant Name: I...J��O W W 1 1 L) S New Tenant: ❑ Yes .No Day Telephone. City Fax Number: R State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued eta s - ? -9�L/o C Qo fate Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: State Company Name: Mailing Address: Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD - Alt plans must be we stamped by Engineer of Record Company Name: 7 Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q: Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh State Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: 0 -3 HP /100,000 BTU Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Sin • le Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CON CTO F,,O�RS NIIN N Company Name: I ► r 1 I ` t V _ Mailing Address: �lY Contact Person: E -Mail Address: C). . Contractor Registration Number:QUAICI Valuation of Mechanical work (contractor's bid price): $ Scope a f W rk (please provi . e detailed informatio ): • ea Use: Residential: Commercial: Indicate type of mechanical work being installed and the quantity below: Q:\Applications'Forms- Applications On Lin&3 -2006 - Permit Application.doc Revised: 9 -2006 bh 9, an New .... ❑ Replacement .... ❑ New .... ❑ Replacement ... City state Zi Day Telephone: '- cP l Fax Number: LOS ' t"` 9R Expiration Date: h to (O . Fuel Type: Electric ❑ Gas ....0 Other: Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: Day Telephone: e1031: Zip BUILDING 0 R 1 ; A([ITHORIZED AGENT: Signature: Mailing Address: Date Application Accepted: Date Application Expires: Staff Initials: Q:\Applications\Forms- Applications On Line 3 -2006 - Permit Application.doc Revised: 9 -2006 bh VILA City Date: 1 / State Page 6 of 6 Receipt No.: R09 - 00168 Initials: WER User ID: 1655 Payee: COMFORT MECHANICAL ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 13079 279.11 RECEIPT Account Code Current Pmts 000.322.102.00.0 223.29 000/345.830 55.82 Total: $279.11 Parcel No.: 0004800003 Permit Number: M09 -010 Address: 12626 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 02/02/2009 Applicant: WILD WEST SHIRTWORKS - BLDG B Issue Date: Payment Amount: $279.11 Payment Date: 02/02/2009 02:12 PM Balance: $0.00 doc: Receipt -06 Printed: 02 -02 -2009 Project: // ,,rr� �, / / / / / / l�I1iG` l Type of In /./ / //G'q f Address: _,,,, - - II /,% e' 2l.. // J4,2 //. Art.l Date Called: Special Instructions: Date Wanted: R Phone No: eg INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 / ivy - / 0 PERMIT NO. / (206)431 -367 t proved per applicable codes. Corrections required prior to approval. .00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be aid at 6300 Southcenter lvd., Suite 100. Call to schedute reinspection. COMMENTS: p or mi4l i o ni 1� Receipt No.: 1Date: Project: /` .Z.) 60 T Sh " ' j Type of Inspection: / L / C , r /iv 4 Address: e 2. 6.x.6. . / /,., Date Called: ,/ a Special Instructions: Date Wanted: Cali. .„D -2 ` /-o 5J p.m. Requester: Phone No: ao4 - q6 -J86> INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 'E 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. COMMENTS: Inspecto 4 7- ,1/ `t r.. 0.00 REINSPECTION FEE EQUIREI Prior to inspection, fee must be aid at 6300 Southcenter B d., Suit 00. Call to schedule reinspection. Receipt No.: r) ie-i- Tocis /.2e ' --il!) /t/ /. A4445 INSPECTION RECORD Retain a copy with permit 1/74 G'K tir ., orrections required prior to approval. 'Date: /916-0 ro 2y, E FIRES: 2 -23 -09 \ ARMOUR UNSDERFER ENGINEERING, INC 13456 SE 27th PI., Suite. 200 Bellevue, WA 98005 (425) 614 -0949 Fax (425) 614 -0950 STRUCTURAL CALCULATIONS FOR: Wild West Roof Top Mechanical Unit 12626 Interurban Ave S, Tukwilla, WA 98168 FILE COPY Ninon No MOq• 0( 0 Plan taw approval is subject to errors and its. Approval of rr...:,.<<., +jnn documents does not authorize irr$irgince. Receipt Client: Comfort Mechanical 6802 S. 220th St. Kent, WA 98032 By Bill Armour SE, SECB \VIIV CODE COMP ANCE APPROVED FEB 0 5 2009 �}T CRYOntokoAla RECEIVED FEB 02 2009 PERMIT CENTER AUE No. 9030 Date: 1/27/2009 Wild West Roof Top Mechanical Unit 12626 Interurban Ave S, Tukwilla, WA 98168 TOPIC PAGES Index 11 Load Criteria LD - 1 Seismic Loads S1 - S2 Wind Loads W1 - W2 Mechanical Unit Support/Anchorage ME1 - ME3 Beam /Purlin DesigP Q B1 - B3 =� Sketches . •0 SSK1 brie elm* o risyq eshorttus tan esob a,9r 3r F ars , - � - Pn fP y Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (425) 614 -0949 Project: Wild West Roof Top Mechanical Unit Address: 12626 Interurban Ave S, Tukwilla, WA 98168 Client: Comfort Mechanical •rte $ • $,4 e t c } 7� } Pg. No: 1 -1 Date: 1/27/09 Job No.: 9030 q 4 Wild West Roof Top Mechanical Unit Gravity Loading `Roof Dead Load: Roofing Plywood Insulation Wood Framing Ceiling Misc / Mech (Tot 11 PSF; (Live Load Seismic Criteria: 2.2 PSF 2.8 PSF 1 PSF 2.1 PSF 1.8 PSF' 1.1 PSF; 25 PSF' Snow Load Short-period Spectral Response, = 1.50 One - second Spectral Response, = 0.518 Cat I, II, III, or IV (Table 1 -1 ASCE 7 -05) 1I Site Class, (Sec 11.4.2, ASCE 7 -05) = D Fa = 1 Fv = 1.5 Roof Live Load Types Snow Load Live Load Rain Load 1 There ais 1 new roof top mechanical unit RTU 1 450 lbs 48" x 31" x 51" tall equiv. uniform load = 9 psf Unit bear on an existing 14" curb on plywood over 2x4 @ 24 "o /c supported by 4x16 @ 8' -0" o/c on 6- 3/4x33 GLB's at 20' -0" A m, Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (425) 614 -094' Project: Wild West Roof Top Mechanical Unit Address: 12626 Interurban Ave S, Tukwilla, WA 98168 Client: Comfort Mechanical Pg. No: LD1 Date: 1/27/09 Job No.: 9030 Seismic Load Calculation for Components and System (Reference: ASCE 7 -05, Chapter 13.3 & 13.6, ICC Seismic Design Parameters 3.10) 0.2s Spectral Response Acceleration, Site Class B, S, _ 1.0s Spectral Response Acceleration, Site Class B, S _ Site Class = Seismic Use Group = Standard - Occupancy Buildings Site Coefficient per S, & Site Class, F = Site Coefficient per S & Site Class, F„ S = F SM1 = F„ S1 = SDS = 2/3 SMS SD1 = 2/3 SM1 Seismic Design Category per SDS (Per ASCE 7. 9.6.1.3) Component amplification factor, a Component Importance factor, 1 Component operating weight, W Component response modification factor, R Height in structure at point of attachment of component, z Average roof height of structure, h Seismic Design Force, F Max. seismic design force, F iona) , Min. seismic design force, Fpmin Seismic Design Force, F Min. seismic design force, Fpmin Seismic Design Force, F Max. seismic design force, F = 1.501 0.518 D I I 1.00 1.50 1.50 0.78 1.001 0.518 D 2.5 (ASCE 7 -05, Table 13.6 -1) 1 (ASCE 7 -05, Section 13.1.3) W (lb) 6 (ASCE 7 -05, Table 13.6 -1) 20 (ft) 20 (ft) (z/h need not exceed 1.0) = 0.4aPSDSWP (1 +2z/h) R p 1 . 6 SDSIpWP = 0 . 3 SDSIpWP (ASCE 7 -05 11.4.1) (ASCE 7 -05 11.4.1) (ASCE 7 -05 11.4.2) (ASCE 7 -05 11.4.3, Table 11.4 -1) (ASCE 7 -05 11.4.3, Table 11.4 -2) (ASCE 7 -05 11.4.3) (ASCE 7 -05 11.4.3) (ASCE 7 -05 11.4.4) (ASCE 7 -05 11.4.4) 0.50 W (Ultimate) 0.30 W 1.60 W 0.36 W, (ASD) (Eq. 13.3 -1) (Eq. 13.3 -2) (Eq. 13.3 -3) (No one third stress increase allowed) Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (425) 614 -0949 Project: Wild West Roof Top Mechanical Unit Pg. No: Address: 12626 Interurban Ave S, Tukwilla, WA 98168 Date: Client: Comfort Mechanical Job No.: S -1 1/27/09 9030 1 4 9030 Wild West Mechanical Seismic Soil Values Tue Jan 27 13:41:14 PST 2009 Conterminous 48 States 2006 International Building Code Zip Code = 98168 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Data are based on a 0.05 deg grid spacing Period Centroid Sa (sec) (g) 0.2 1.501 1.0 0.518 Conterminous 48 States 2006 International Building Code Zip Code = 98168 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 = Fv x S1 Site Class D Period Centroid Sa (sec) (g) 0.2 1.501 1.0 0.777 (Ss) (S1) Conterminous 48 States 2006 International Building Code Zip Code = 98168 Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2/3 x SM1 Site Class D Period Centroid Sa (sec) (g) 0.2 1.001 (SDs) 1.0 0.518 (SD1) (SMs, Fa = 1.000) (SM1, Fv = 1.500) Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (425) 614 -0949 Project: Wild West Roof Top Mechanical Unit Pg. No: S - 2 AUE Address: 12626 Interurban Ave S, Tukwilla, WA 98168 Date: 1/27/09 �" Client Comfort Merhaniral .lnh No : 9030 I ASCE Wind Method 2 Analytical Proceedure per ASCE 7-05 Data Input V= Category: Hurr. Prone? Iw= Exposure 85 MPH II All Buildings (Typ.) No Col 3 1 C Fact. = 0.958 Lh = H= x = z= h= Kd= Kz= Kzt= Kzt= Direction of Wind 'upwind of crest Pos. IType: 2- dimensional escarpments 1 (Direction: Downwind of Crest - 1 4000 FEET 350 FEET 4000 FEET 16 FEET 16 FEET 0.85 p. 76, Table 6-4 0.86 p. 75, Table 6 -3 1.11 p. 47, Figure 6-4 1.00 Source: Table xxx Dist. Upwind of Crest to Half Ht of Hill or Escarp. Ht. of Hill or Excarp. Relative to the upwind terrain Dist (Upwind or Downwind) from the crest to the building site Ht above Local Ground Level Mean Ht above Local Ground Level Kz Mean qz= 0.00256 *Kz *Kzt *Kd*V ^2 *I = 15.1 psf gh(gzeval.At Mean) = 15.1 psf 0.86 Ignored if Type is User 1 Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA Project: Wild West Roof Top Mechanical Unit Address: 12626 Interurban Ave S, Tukwilla, WA 98168 Client: Comfort Mechanical 98005 (425) 614 -0949 Pg. No: W1 Date: 1/27/09 Job No.: 9030 Area (ft^2) Location 0 10 20 50 100 200 500 4 &5 1 1 0.95 0.9 0.82 0.8 0.72 4 -1.1 -1.1 -1.05 -0.98 -0.93 -0.9 -0.8 GC 5 -1.4 -1.4 -1.3 -1.15 -1.05 -0.95 -0.8 Components & Cladding Summary: V= Category: Hurr. Prone? Iw= Exposure 85 MPH II All Buildings (Typ.) No 1 C Can be changed on Com. (Building Enc. Enclosed Buildings Length = Width = Ht = Roof Angle= H <= 60 qh = q= qi = Not App. PSF Not App. PSF Gcpi = 0.18 -0.18 (Specific Cladding: Building Width Exposure Area = Location = GCpf = p = 12.4 PSF -18.4 PSF -23.8 PSF 17.8 PSF ASCE 6.5.15.1 increase= 1.9 Pmax = Pmin = 100 FEET 100 FEET 20 FEET 0 -10 Degrees 15.06 PSF Longer Dimension Shorter Dimension Mech Unit 100 Unit Width 4 C 12.8 SF 5 Row Num = 4 1 -1.4 33.8 PSF I -45.2 PSF Copy Down as Needed Zg = a = z= Kz = 900 9.5 16 0.86 K1 /(H /Lh) 0.85 K1 = 0.074375 Kzt = 1.11 Exp. Fact= 0.96 Length 0 • Clad /Bld = 1.00 J Width Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (425) 614 -0949 Project: Wild West Roof Top Mechanical Unit Pg. No: W2 Address: 12626 Interurban Ave S, Tukwilla, WA 98168 Date: 1/27/09 Gravity Loading IDead Load 11 PSF (Live Load 25 PSF 'Joist L = 1 20IFT 1 Unit Wt =' 450JLBS ' W /Curb Adaptor Expected Unit Wt = 0 LBS Balance = 450 LBS Dist. = 1 2.3IFT Per Struct Drawings Old unit x16 @ 1 8JFT OC 'Height = 1 3.10tFT 1.2I FT Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (425) 614 -0949 Project: Wild West Roof Top Mechanical Unit Pg. No: ME1 Address: 12626 Interurban Ave S, Tukwilla, WA 98168 Date: 1/27/09 Client: Comfort Mechanical Job No.: 9030 1' Purlin Check Dead Load = Live Load = Tot. Load = Span = Trib = Dist. From End Wdl = Wdl with (e) unit WII= Wtl= Mom (Exist) = V (Exist) = Bal. (N)Unit = 450 LBS Unit Size (Ft) = Net Wt. = 450.0 LBS 1/2 Unit on Support ? Wt. on Joist Madd / Joist = Vadd / Joist = 11 PSF 25 PSF 36 PSF 20 FEET 8 FEET 2.3 FEET 88 PLF 88 PLF 200 PLF 288 PLF 14400 LBS FEET 2880 LBS 4 x 2.6 450.0 LBS 720 LBS FT 144.0 LBS 5 % Increase 5 % Increase 4 Wt = Rxn= V max= M max = w shear = w mom. = No Reduction Allowed for Snow No Yes All Unit is on Joist (Existing ME Unit to be replaced 0 LBS 0 LBS 0 LBS 0 LBS FT 0 PLF 0.00 PLF 1 ICheck Joist where known: 1 V mech = 398.3 LBS See sheet s B1 which shows purlin is adequate to support new unit. Sheet B2 shows that the existing 2x4 subpurlins are inadequate, sheet B3 shows the design of a member to lap along side of the inadequate subpurlins. Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (425) 614 -0949 1 Project: Wild West Roof Top Mechanical Unit Pg. No: ME2 Address: 12626 Interurban Ave S, Tukwilla, WA 98168 Date: 1/27/09 Client: Comfort Mechanical Job No.: 9030 Long Dim to Load Short Dim to Wind Pmax = OTM = RM = Ratio O/R = 777.8 LBS Wind Gov. 1672.3 LBS FT 497 LBS FT 0.297345 Anchorage Required Pmax = OTM = RM = Ratio O/R : 505.6 LBS Wind Gov. 1087.0 LBS FT 765.0 LBS FT 0.7 Anchorage Required Deck Height = I 16IFEET Unit Height = 4.300 FEET Min Trib Area= Zone = p wind = wind Max = 11.2 SF 5 33.8 PSF -45.2 PSF 45.2 PSF p P Long wind = 777.8 LBS Worst Case P Trans wind = 505.6 LBS (P siesmic = 160.8 LBS Worst Case T net = 451.9 LBS Metal to Metal: !Add: 2 #12 Screws Curb to Curb Unit to Curb: Try: #12 Min Screws @ No Screws = 2 Min Screw Cap = 280 LBS in 43 Mil Curb T cap = 582.4 LBS 15 In. on centers 451.9 Therefore OK Use: #12 Min Screws @ 15 In. on centers Curb to Wood: Try: No Screws = Screw Cap = T cap = #10 Min Screws @ 4 Min 136 LBS in wood I r 10 In. on centers 544 LBS > 451.9 Therefore OK Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (425) 614 -0949 Project: Wild West Roof Top Mechanical Unit Pg. No: ME3 Address: 12626 Interurban Ave S, Tukwilla, WA 98168 Date: 1/27/09 Client: Comfort Mechanical Job No.: 9030 rPurlin Existing 4x16 DF #1 Each side of Unit Beam Design (Simple Span) DL= 11 psf LL= 25 psf Total Load = 36 psf I P DL= 300 LBS P LL = 0 LBS Total P = 300 LBS i 2/3 weight of mechanical unit Span = Trib for w = Wall load= Height of wall= 03 (DL) Additional = CO (LL) Additional Self Weight= 20 ft 03 (DL +LL) = 303 plf w (L L) = 200 plf Shear (DL +LL) = 3030 lbs Moment (DL +LL) — 15150 ft-Ibs Try 4x16 8ft 0 psf Oft 0 plf 0 plf 15 plf Area = 53.4 in S = 135.7 in' Ix = 1034.4 in Deflection, An = 0.637 in Deflection, A = 0.409 In Project: "Wild West Mechanical Unit" Address: "Tukwilla, WA" Client: "Comfort Mechanical" Allowable Stress, Mat: D -Fir#1 Fv x CD x Coth for Shear, F,; = 180 x 1.15 x 1.00 = 207 psi Fb x CD x CF x Cr for Bending, Fb' = 1000 x 1.15 x 0.97 x 1.00 = 1120 psi Rxn. @ A = Rxn. @ B = E = 1700000 psi FOR BEAMS WITH A CONCENTRATED LOAD a@ "a" : P = 300 Ibs a = 2.3 ft RA = 266 Ibs RB = 35 lbs RDL = 1030 lbs R = 2000 lbs 3296 lbs 3065 lbs Max Shear & Moment With Point Load V max = 3296 Ibs M max = 15492 ft-lb b= 3 1/2 in d= 151/4 in L / 377 < L/ 240 OK 1.6 L / 586 < L/ 360 OK 1.6 b= X= AMAx @Xfora >b = AMAx @Xfora <b = AMAxLL @Xfora >b = Amu( LL @Xfora <b = ATL for (A(DL + LL) = A,REQ D = 23.9 in SX,REQ'D = 166.0 in3 OK 55.3 NOT OK -22.3 4 Actual Change in Moment = 2.257 % Negligable - OK I USE: D -Fir#1 4x16 or higher I AU Armour Unsderfer En ineerin 13456 SE 27th PI. Ste. 200 Bellevue, WA 98005 (425) 4- 4 g q, 5 ( 5) 61 09 9 Pg No.B -1 Date:1 /28/2009 Job No: 9030 17.7 ft 8.53 ft 0.01 in 0.02 in 0.00 in 0.00 In 0.62 in ISub Purlin Sub Purlin between 4x16 under Unit edge Beam Design (simple span) DL= LL= Total Load = P DL= P LL = Span = Trib for w = Wall load= Height of wall= '(DL) Additional = �(LL) Additional = Self Weight= Area = S = I = Deflection, ATL = Deflection, ALL = 22.0625 psf 25 psf 47.0625 psf Try 2x4 0 LBS 0 LBS Total P = 0 LBS I 8ft 2ft 0 psf Oft 0 pif 0 pif 1 pif (DL +LL) = 95 plf w (L L) = 50 plf Shear (DL +LL) = 381 Ibs Moment (DL LL) = 761 ft-Ibs 5.3 in 3.1 in' 5.4 in' 0.955 in 0.502 in Allowable Stress, a= RA = RB = RDL = RLL = Rxn. @A= Rxn. @B= OK 40.1 NOT OK -194.6 L / 101 > L/191 > Armour Unsderfer Engineerina,13456 SE 27th PI Project: "Wild West Mechanical Unit" Address: 'Tukwilla, WA" Client: "Comfort Mechanical" Mat: D -Fir#1 Fv x CD x Coth for Shear, Fv = 180 x 1.00 x 1.00 = 180 psi for Bending, Fb' = 1000 Fb x CD x CF x Cr x 1.00 x 1.00 x 1.00 = 1000 psi E = 1700000 psi FOR BEAMS WITH A CONCENTRATED LOAD ( "a" P = 0 Ibs 4 ft 0 lbs 0 lbs 181 Ibs 200 Ibs 381 lbs 381 lbs Max Shear 8 Moment V max = 381 Ibs M max = 761 ft-lb b= 11/2 in d= 31/2 in L/ 240 NOT OK 0.4 L/ 360 NOT OK 0.5 b= X= AMAX @Xfora >b = AMAx @Xfora <b = AMAX LL @ X for a > b = AMAX LL @ X for a <b = OTL for (D(DL + LL) = O ft 4.00 ft 0.00 in 0.00 in 0.00 in 0.00 I n 0.95 in A,RE = 3.2 ln` SX,REQ'D = 9.1 in' USE: D -Fir#1 2 x 4 or higher I ., Ste. 200. Bellevue, WA 98005 (425) 614 -0949 Pg No.B -2 Date:1 /28/2009 Job No: 9030 (Sub Purlin Reinforce Subpurlin spanning under Unit edges Beam Design (simple span) DL= 22.0625 psf LL= 25 psf Total Load = 47.0625 psf P DL= P LL = Total P = 0 LBS I Span = Trib for w = Wall load= Height of wall= 0) (DL) Additional = w(LL) Additional = Self Weight= (0 (DL +LL) = 99 plf (LL) = 50 plf Shear (DL +LL) _ 397 Ibs Moment (DL +LL) _ 793 ft-Ibs Try 4x6 Area = S = I = 0 LBS 0 LBS 8ft 2ft 0 psf Oft 0 plf 0 plf 5 plf 19.3 in 17.6 in' 48.5 in Allowable Stress, Fv x CD x Coth for Shear, F,; = 180 x 1.00 x 1.00 = 180 psi Fb x CD x CF x Cr for Bending, Fb' = 900 x 1.00 x 1.00 x 1.00 = 900 psi Rxn. @ A = Rxn. @ B = % OK 82.9 OK 39.9 Mat: D -Fir#2 E = 1600000 psi FOR BEAMS WITH A CONCENTRATED LOAD Caa "a" : P = 0 Ibs a= 4 ft RA = 0 Ibs Rs = 0 Ibs RDL = 197 Ibs R = 200 lbs 397 Ibs 397 lbs Max Shear & Moment V max = 397 Ibs M max = 793 ft-lb b= 31/2 in d= 51/2 in A % Deflection, ATL = 0.118 in L / 815 < L/ 240 OK 3.4 Deflection, A = 0.059 in L / 1617 < L/ 360 OK 4.5 ►4 h b= X= AMAX @Xfora >b = AMAx @ X for a <b = AMAxLL @Xfora >b = AMAxLL @Xfora <b = An for (il(DL + LL) A,REQ'D = 3.3 in` SX,REQ'D = 10.6 in 3 USE: D -Fir#2 4 x 6 or higher Armour Unsderfer Engineerina.13456 SE 27th PI., Ste. 200, Bellevue, WA 98005 (425) 614 -0949 Project: "Wild West Mechanical Unit" Pg No.B -3 Address: "Tukwilla, WA" Date:1/28/2009 Client: "Comfort Mechanical" Job No: 9030 4ft 4.00 ft 0.00 in 0.00 in 0.00 in 0.00 In 0.12 in Unit is aproximately 12" clear of beam .A5 8' -0" New Mechanical Unit 450 Ibs max unit weight with accessories I(E) GLB 1 (E) GLB ATTACHMENT NOTE: - ATTACH MECHANICAL UNIT TO CURB WITH #12 SCREWS AT 10" O /C, MIN (4) PER SIDE. - ATTACH CURB TO FRAMING BELOW PLYWOOD WITH MINIMUM OF (4) #12X2 -1/2" SCREWS PER SIDE Partial Roof Plan with New Mechanical Units NTS (E) 4x16 Purlins (N) 4x6 HF #2 under side of I unit with Simpson U46 each I end Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (425) 614 -094 � _ � Project: Wild West Roof Top Mechanical Unit Pg. No: SSK 1 Address: 12626 Interurban Ave S, Tukwilla, WA 98168 Date: 1/27/09 Client Comfort Mechanical Job No.: 9030 Project Info Project Address Wild West Shirtworks Date 1/22/2009 12626 Interurban Ave s For Building Department Use Tukwila, WA 98168 Applicant Name: Jof fre Sechier Applicant Address: 6802 S. 220th St., Kent, WA 98032 Applicant Phone: 425 -251 -9840 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form ' roject Summary PRJ ;SUM Revised July 2007 FILE COPY Permit No.. O W' O[ Q Plan review approval is subject to errors and omissions. Annmusil of cnnonntfinn r4nv'mor.•- -" �•+�, M O ct %- 0 I 0 rat lcrer,u rvrc COMPLIANCE APPROVED FEB 0 5 20P9 WE aty Of TIlo/dlld .,R11LDIMG DIVISION _ RECE1vFr FEB 02 2009 PERMIT CENT& Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location Rtu -1 Carrier 488D- 0240403 24000 800 Econo 13 seer 32000 Roof Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM SP' HP /BHP Flow Control Location of Service Efficiency Rtu -1 Carrier 489D- 0240403 32000 800 Econo 40000 32000 0.800 Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency Rtu -1 Carrier 489D- 0240403 32000 800 Econo 40000 32000 0.800 Project Info Project Address Wild West Shirtworks Date 1/22/2009 12626 Interurban Ave s For Building Dept. Use Tukwila, WA 98168 Applicant Name: Joffre sechier Applicant Address: 6802 S. 220th St., Kent, WA 98032 Applicant Phone: 425 -251 -9840 Mec;hanical Summary MECH ;SUM y 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Includes Plans 2006 Washington State Nonresidential Energy Code Compliance Form Replace existing 2 -ton rooftop gas packaged a/c unit with new 2 -ton rooftop gas packaged a/c unit. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Revised July 2007 Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 1 if available. 2 As tested accord ng to Table 14 -1A through 14-1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. ; If Heating /Cooling or Cooling Only: 0 Constant vol? ✓ Air cooled? 1 Packaged sys? ❑ <20,000 Btuh? ❑ Split system? . Economizer included? If Heating Only: < ❑ <5000 cfm? o ❑ <70% outside air? Mechanical Summary (back) MECH -S;UM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ( START 2006 Washington State Nonresidential Energy Code Compliance Form <5000 cfm? Econo Included? Simple System Allowed (section 1420) Air Cooled, Constant Vol? <70% OSA Use Complex Systems (section 1430) ingle Package Unit? •ol Ca <20,000 Btuh? otal Ca . wo economize <240,000 Btuh or 10 %? plit Syste <= 84,000 Btuh? Outd or Adjacent to utdoor of Ca <54,000 Btuh? Heating Only Yes — Yes* Reference Section 1421 Heating /Cooling or Cooling Only Yes Yes Reference Section 1423 Yes Yes Yes Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical Permit 2006 Washington State Nonresidential Plans ;Checklist MECH ;CHK Energy Code Compliance Forms Revised July 2007 Project A dd r ess wild West Shirtaorxa Date 1/22/2009 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance yes 1411.4 Pkg..elec. htg.& clg. List heat pumps on schedule 141 yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Mi n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls n.a. 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum Mi n.a . 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types M1 n.a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control n.a. 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans n.a. 1423 Economizers Equipment schedule 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule M1 n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance yes 1413.3 Integrated operation Indicate capability for partial cooling Mi n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems n.a. 1414.1 Duct sealing Indicate sealing necessary n.a. 1414.2 Ductiinsulation Indicate R -value of insulation on duct n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan Mi n.a. 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training M1 n.a. 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report n.a. 1434 Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer M1 SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n.a. 1441 Elec. heater Indicate R -10 insulation under tank n.a. 1442 Shut-off controls Indicate automatic shut -off n.a. 1443 Pipe Insulation Indicate R -value of insulation on piping n. a. 1452 Heat Pump COP Indicate minimum COP of 4.0 yes 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n. a. 1454 Pool covers Indicate vapor retardant cover n. a . 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form no is circles Tor any question, proviae explanation: ACTIVITY NUMBER: M09.010 DATE: 02 -02 -09 PROJECT NAME: WILD WEST SHIRTWORKS SITE ADDRESS: 12626 INTERURBAN AVE S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: au ? .-414)1 BS Building Divi X, Public Works LI Complete TUES/THURS ROUTING: Please Route APPROVALS OR CORRECTIONS: Approved REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 oisr 0 PERMIT CO U COPY PLAN REVIEW /ROUTING SLIP Structural Review Required 14t" AI/4 x3-oY Fire Prevention )IZ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete DUE DATE: 02 -03 -09 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: n No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 03 -03 -09 Approved with Conditions r Not Approved (attach comments) n Notation: DATE: Planning Division Permit Coordinator Not Applicable Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 COLONIAL AM CAS it SURETY OF MD LPM4041162 06/01/2002 Cancelled elled $6,000.00 05/15/2002 1 COLONIAL AM CAS Et SURETY OF MD LPM4041162 06/01/1999 06/01/2002 $4,000.00 Name Role Effective Date Expiration Date JACKSON, SHIRLEY A 01/01/1980 JACKSON, HERB J 01/01/1980 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LRI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information COMFORT MECHANICAL INC Phone 4252519840 Address 6802 S0. 220TH STREET Name Suite /Apt. City State Zip County Business Type Parent Company KENT WA 98032 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601954041 ACTIVE COMFOMI015LA CONSTRUCTION CONTRACTOR 6/1/1999 6/1/2010 FIVESM *010JT FIVESSE941 KU HTG /VENT /AIR CONDITIONING UNUSED Business Owner Information Bond Information Insurance Information https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= COMFOMI015 LA Page 1 of 2 02/13/2009 ls`tA" i aT A: 12626 Interurban Ave S, Tukwila, WA 98168 - 3314 0 your request and go! Free MapQuest directions by phone: 1. 800 FREE411 (1 - 373 - 3411). MADQUbST. S 17,.`P'. St �t ` tt a 122nd 5t . * N . '1:,34.. . 0 �.. v, . ,�' it w 4 g 'i S t lent'4Nrti ' . -__ - _ C Al .le .___ y I c d : t ! q I 4: I ' 1 . - -- t .. I s t I _.. uSc .\ r ii3ir l'Iaati t l q .9. `�- 5 0 , fit S 13()T s, / y �� •3,. 131st 5t_._. `\ irj 5 133rd St. I .. 5 13rd .,St .g I. ! S135th St _ 4? MOO u est Inc. VICINITY MAP t 5 1301H 5 3 131ST ST 5 12ith St_, 5 12601 St' I CI 2008 K mg County „_;•;.� : :.._ _ _�12t}tti SL qq 'I V \-o t.,3 cis d ( 99 S 1331 "2D S f Southgate Perk S t22hD ST Tukwila Community Cenjter 49 sr Foster. - - -- vi hl plData :SD ZOU N h t if The Information includes) on.this map has been compiled by King County staff from a variety of sources and Is subloct t0 tl+angn Wlglnyt ((ips1159 presentations or warranties, express or Implied, an to accuracy, completeness, timellnass or tights the use gtkeptt �t d aKirtg t tpq; This' document le nof'inlerided for use as a survey product. King County shall not be liable for any general, special il(tl.fp, '40401,10 ,o t@4t1 ei 141# County makes no re damngas including, but not limited to, lost revenues or lost profits resulting from the use or misuse of the informallon cr'ti I` pn Ilia p Arty Iq thiy map or information, on this pap Is prohibited{ except by written permission of King County, 1 11 d 5 4V4 r ' Oota: 1/22/2009 °, otirce King County iM AP Property Information (http: /Nmw.matrokc.gov /GISriMAP) SITE PLAN t R 60t1tt,. Project; Wild West Shirts Prepared By: . Part Number :48SD - 0240403 ARI SEER: 13.00 Base Unit Weight: 450 lb Base Unit Dimensions Unit Length' 48.3 in Unit Width 32.7 in Unit Height: 39,0 in Unit Voltage - Phase -Hertz 2304-60 Air Discharge Horizontal Fan Drive Type Direct Actual Airflow: 824 CFM Site Altitude 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB' 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU /Ib Evaporator Leaving Air DB' 60,2 F Evaporator Leaving Air WB 58.5 F Evaporator Leaving Air Enthalpy 25.34 BTU /Ib Net Cooling Capacity: 22.61 MBH Net Sensible Capacity: 17.66 MBH Total Unit Power Input' 2.06 kW Coil Bypass Factor: 0.102 Heating Performance Heating Airflow: • . 824 CFM Entering Air Temp: 70,0 F Leaving Air Temp: 105.9 F Gas Input Capacity' 40,0 MBH Gas Heating Capacity: - 32.00 MBH Temperature Rise:. 35.9 F Supply Fan External Static Pressure 0.40 in wg Options / Accessories Static Pressure Economiser: • ' 0.20 in wg Wet Coil' 0.04 in wg Total External Static: . 0.64 in wg Fan RPM: 1050 Fan Motor Size, hp' 1/3 NOTE: Medium Motor Speed, Horz Electrical Data Minimum Voltage: 187 Maximum Voltage: 253 Compressor RLA• 10.4 Compressor LRA: 54 Outdoor Fan FLA (ea): 0.9 Indoor Fan Motor FLA: 2 Power Supply MCA: 15.9 Power Supply MOCP, Fuse or HACR, U.S.A.: 25 Acoustics ' Sound Rating: 72.0 db Sound Power Levels, db re 10E -12 Watts Packaged Rooftop Builder 1.19b Performance Summary For 2T Gas Ele EQUIPMENT SCHEDULE t Le al descri•tion LEWIS C C -D C # 37 BEG N 81 -44 -15 E 199.17 FT FROM HUB AT END OF CURVE ON CENT LN OF DUWAMISH- RENTON JUNCTION RD SD HUB BEING APPROX 1200 FT N AND 440 FT W OF 1/4 COR BET SECS 14 & 15 -23-4 TH N 49 -24 -00 W 2535 FT TH N 09 -36 -00 E 52 FT TO TRUE BEG TH 5 82 -40 -30 E 590 FT TH N 59 -22 -30 E 643.35 FT TH N 01 -51 -30 W 343 FT TO LEFT BANK OF DUWAMISH RIVERBEING NLY BOUNDRY OF LEWIS D C TH SWLY ALG SD BANK OF RIVER TO PT N 00 -39-40 W OF TRUE BEG TAI 5 00 -39 -40 E TO TRUE BEG ALSO POR OF C LY W OF ABOVE DESCRIBED LAND SLY 16.15 FT AND A 16 FT STRIP ADJ AND PARL TO ELY LN OF R/W OF P S ELEC CO FOR JOINT RD TGW LOT 47 OF PLAT OF RIVERSIDE INTERURBAN TRS 01/21/2009 12:24PM • PARTIAL ROOF PLAN PROJECT DESCRIPTION: 1. REPLACE 1 EXISTING 2 -TON ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT (RTU -1) WITH NEW 2 -TON GAS PACKAGED AIR CONDITIONING UNIT WITH ECONOMIZER. GENERAL NOTES: 1. INSTALL 7 -DAY PROGRAMMABLE THERMOSTAT WITH 5° DEADBAND. 2. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING. 3. INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 4. ROUTE CONDENSATE TO SPLASH BLOCK. 5. PROVIDE COMMISIONING REPORT WITH OPERATIONS AND MAINTENANCE MANUALS. SEPARATE PERMIT REQUIRED FOR: Ie ctrr tric a E l �. lecc (P ii '; Piping City of Tukwila BUILDING DIVISION REVISiONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittt I and may include additional plan f =F. 7, FILE COPY Pern,K No. M �q 0 ( 0 Plan review approval is subject to errors and omissio Approval of construction documents does not authori . the violatiion of dopted code or ordinance. Rece pp of approved Fipd copy and conditions is acknowledg B y `1101111110* (N) RTU-1 [j ,p) City OfltikwIla BUILDING DIVISION LIMMU I CODE COMPLIANCE APPROVED FEB 0 5 2009 i,J ER City Of ` ulOviIa BUILDING DIVI ION RECEIVED FEB 02 2009 PERMIT CENTER action 68 1 LI DATE: SCALE; DRAWN: CHECKED: t. NA 1 ,................ ...) ls`tA" i aT A: 12626 Interurban Ave S, Tukwila, WA 98168 - 3314 0 your request and go! Free MapQuest directions by phone: 1. 800 FREE411 (1 - 373 - 3411). MADQUbST. S 17,.`P'. St �t ` tt a 122nd 5t . * N . '1:,34.. . 0 �.. v, . ,�' it w 4 g 'i S t lent'4Nrti ' . -__ - _ C Al .le .___ y I c d : t ! q I 4: I ' 1 . - -- t .. I s t I _.. uSc .\ r ii3ir l'Iaati t l q .9. `�- 5 0 , fit S 13()T s, / y �� •3,. 131st 5t_._. `\ irj 5 133rd St. I .. 5 13rd .,St .g I. ! S135th St _ 4? MOO u est Inc. VICINITY MAP t 5 1301H 5 3 131ST ST 5 12ith St_, 5 12601 St' I CI 2008 K mg County „_;•;.� : :.._ _ _�12t}tti SL qq 'I V \-o t.,3 cis d ( 99 S 1331 "2D S f Southgate Perk S t22hD ST Tukwila Community Cenjter 49 sr Foster. - - -- vi hl plData :SD ZOU N h t if The Information includes) on.this map has been compiled by King County staff from a variety of sources and Is subloct t0 tl+angn Wlglnyt ((ips1159 presentations or warranties, express or Implied, an to accuracy, completeness, timellnass or tights the use gtkeptt �t d aKirtg t tpq; This' document le nof'inlerided for use as a survey product. King County shall not be liable for any general, special il(tl.fp, '40401,10 ,o t@4t1 ei 141# County makes no re damngas including, but not limited to, lost revenues or lost profits resulting from the use or misuse of the informallon cr'ti I` pn Ilia p Arty Iq thiy map or information, on this pap Is prohibited{ except by written permission of King County, 1 11 d 5 4V4 r ' Oota: 1/22/2009 °, otirce King County iM AP Property Information (http: /Nmw.matrokc.gov /GISriMAP) SITE PLAN t R 60t1tt,. Project; Wild West Shirts Prepared By: . Part Number :48SD - 0240403 ARI SEER: 13.00 Base Unit Weight: 450 lb Base Unit Dimensions Unit Length' 48.3 in Unit Width 32.7 in Unit Height: 39,0 in Unit Voltage - Phase -Hertz 2304-60 Air Discharge Horizontal Fan Drive Type Direct Actual Airflow: 824 CFM Site Altitude 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB' 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU /Ib Evaporator Leaving Air DB' 60,2 F Evaporator Leaving Air WB 58.5 F Evaporator Leaving Air Enthalpy 25.34 BTU /Ib Net Cooling Capacity: 22.61 MBH Net Sensible Capacity: 17.66 MBH Total Unit Power Input' 2.06 kW Coil Bypass Factor: 0.102 Heating Performance Heating Airflow: • . 824 CFM Entering Air Temp: 70,0 F Leaving Air Temp: 105.9 F Gas Input Capacity' 40,0 MBH Gas Heating Capacity: - 32.00 MBH Temperature Rise:. 35.9 F Supply Fan External Static Pressure 0.40 in wg Options / Accessories Static Pressure Economiser: • ' 0.20 in wg Wet Coil' 0.04 in wg Total External Static: . 0.64 in wg Fan RPM: 1050 Fan Motor Size, hp' 1/3 NOTE: Medium Motor Speed, Horz Electrical Data Minimum Voltage: 187 Maximum Voltage: 253 Compressor RLA• 10.4 Compressor LRA: 54 Outdoor Fan FLA (ea): 0.9 Indoor Fan Motor FLA: 2 Power Supply MCA: 15.9 Power Supply MOCP, Fuse or HACR, U.S.A.: 25 Acoustics ' Sound Rating: 72.0 db Sound Power Levels, db re 10E -12 Watts Packaged Rooftop Builder 1.19b Performance Summary For 2T Gas Ele EQUIPMENT SCHEDULE t Le al descri•tion LEWIS C C -D C # 37 BEG N 81 -44 -15 E 199.17 FT FROM HUB AT END OF CURVE ON CENT LN OF DUWAMISH- RENTON JUNCTION RD SD HUB BEING APPROX 1200 FT N AND 440 FT W OF 1/4 COR BET SECS 14 & 15 -23-4 TH N 49 -24 -00 W 2535 FT TH N 09 -36 -00 E 52 FT TO TRUE BEG TH 5 82 -40 -30 E 590 FT TH N 59 -22 -30 E 643.35 FT TH N 01 -51 -30 W 343 FT TO LEFT BANK OF DUWAMISH RIVERBEING NLY BOUNDRY OF LEWIS D C TH SWLY ALG SD BANK OF RIVER TO PT N 00 -39-40 W OF TRUE BEG TAI 5 00 -39 -40 E TO TRUE BEG ALSO POR OF C LY W OF ABOVE DESCRIBED LAND SLY 16.15 FT AND A 16 FT STRIP ADJ AND PARL TO ELY LN OF R/W OF P S ELEC CO FOR JOINT RD TGW LOT 47 OF PLAT OF RIVERSIDE INTERURBAN TRS 01/21/2009 12:24PM • PARTIAL ROOF PLAN PROJECT DESCRIPTION: 1. REPLACE 1 EXISTING 2 -TON ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT (RTU -1) WITH NEW 2 -TON GAS PACKAGED AIR CONDITIONING UNIT WITH ECONOMIZER. GENERAL NOTES: 1. INSTALL 7 -DAY PROGRAMMABLE THERMOSTAT WITH 5° DEADBAND. 2. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING. 3. INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 4. ROUTE CONDENSATE TO SPLASH BLOCK. 5. PROVIDE COMMISIONING REPORT WITH OPERATIONS AND MAINTENANCE MANUALS. SEPARATE PERMIT REQUIRED FOR: Ie ctrr tric a E l �. lecc (P ii '; Piping City of Tukwila BUILDING DIVISION REVISiONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittt I and may include additional plan f =F. 7, FILE COPY Pern,K No. M �q 0 ( 0 Plan review approval is subject to errors and omissio Approval of construction documents does not authori . the violatiion of dopted code or ordinance. Rece pp of approved Fipd copy and conditions is acknowledg B y `1101111110* (N) RTU-1 [j ,p) City OfltikwIla BUILDING DIVISION LIMMU I CODE COMPLIANCE APPROVED FEB 0 5 2009 i,J ER City Of ` ulOviIa BUILDING DIVI ION RECEIVED FEB 02 2009 PERMIT CENTER