Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M09-013 - VERIZON BUSINESS
VERIZON BUSINESS 12682 GATEWAY DR M09 -013 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: doc: IMC -10/06 2716000020 12682 GATEWAY DR TUKW Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA Contractor License No: MCKINCL942DW Value of Mechanical: 320,000.00 Type of Fire Protection: SPRINKLERS /AVA Cityef Tukwila Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us VERIZON BUSINESS 12682 GATEWAY DR , TUKWILA WA RREEF AMERICA REIT II CORP/ PO BOX 4900 #207 , SCOTTSDALE AZ K. CRAIG MANAWES, PE ONE VILLAGE DR, STE 500 , ABILENE TX MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALLATION OF (4) 30 -TON CRAC UNITS, (1) 163 -TON AIR COOLED CHILLER, (1) 15 -HP CHILLED WATER PUMP, AND ASSOCIATED CHILLED WATER PIPING. PROJECT WILL ALSO INCLUDE RELOCATION OF EXISTING CHILLED WATER PIPING AND RELOCATION OF (1) 30 -TON CRAC UNIT. EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 4 * * continued on next page ** M09 -013 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 325 695 -1090 Phone: (206)762 -23311 Expiration Date: 03/16/2010 M09 -013 07/14/2009 01/10/2010 Fees Collected: $3,249.00 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 2 Printed: 07 -14 -2009 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constru or the a ance of work. I am authorized to sign and obtain this mechanical permit. Signature: � %N i Date: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: M09 -013 Issue Date: 07/14/2009 Permit Expires On: 01/10/2010 Date: —2'' 1-(49? This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -013 Printed: 07 - 14 - 2009 Parcel No.: 2716000020 Address: Suite No: Tenant: doc: Cond -10/06 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12682 GATEWAY DR TUKW VERIZON BUSINESS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 11: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. M09 -013 ISSUED 02/05/2009 07/14/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the M09 -013 Printed: 07 -14 -2009 doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us manufacturer's installation instructions. (IIVIC 606.1, 606.2.1) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** M09 -013 Printed: 07 -14 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doc: Cond -10/06 Print Name: UCC ` ,6e) 5 Date: M09 -013 Printed: 07 -14 -2009 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www, ci. tkwila. wa. us SITE LOCATION . I Site Address: 12682 Gateway Drive South Tenant Name: VERIZON Business Property Owners Name: RREEF America REIT II Corporation Mailing Address: PO Box 4900 #207 CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: K. Craig Manawes, PE Mailing Address: One Village Drive, Suite 500 Abilene TX 79606 E -Mail Address: craig.manawes @wta- inc.com MECHANICAL CONTRACTOR INFORMATION � Company Name: TBD Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: . ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Kord S. Kurisu, Architect Mailing Address: 13028 Harbour Hts. Dr. Contact Person: Kord Kurisu E -Mail Address: kskurisu @msn.com Company Name: WTA, Inc. Mailing Address: One Village Drive, Suite 500 MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Contact Person: K. Craig Manawes, PE E -Mail Address: craig.manawes @wta- inc.com H:\Applications\Fonns- Applications On Line\2009 Applications \I.2009 - Mechanical Pemut Applicationdoe Revised: 1 -2009 bh Mechanical Permit No. Project No. (For office use only) King Co Assessor's Tax No.: 271600 -0070 Suite Number: New Tenant: Scottsdale City Day Telephone: (325) 695 -1090 City State Fax Number: (325) 695 -3757 M u ki lted Abilene • City State Day Telephone: (425) 870 -0368 Fax Number: (425) 741 -0936 ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record City Day Telephone: Fax Number: AZ State WA TX State (325) 695-1090 (325) 695 -3757 Floor: 1 ❑ Yes m..No State 85261 Zip Zip Zip 98275 Zip 79606 Zip Page 1 of 2 Unit Type: J Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM 4 Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Fumace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment 2 Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Date Application Accepted: 04,t71-1 i o9 Date Application Expires: 0 J o' Staff Initials: Valuation of Project (contractor's bid price): $ 320,000 Scope of Work (please provide detailed information): Project will include installation of (4) 30 -ton CRAC units, (1) 163 -ton air cooled chiller, (1) 15 -HP chilled water pump, and associated chilled water piping. Project will also include relocation of existing chilled water piping and relocation of (1) 30 -ton CRAC unit. Use: Residential: New ❑ Replacement ❑ Commercial: New ® Replacement ❑ Fuel Type: Electric ® Gas ❑ Indicate type of mechanical work being installed and the quantity below: PERMIT APPIICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER O D NT: Signature: Print Name: K. Craig Manawes, PE Mailing Address: One Village Drive, Suite 500 H:\Applications\Forns- Applications On Line\2009 App ications \I -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh • • Other: Chilled Water Abilene City Date: 02/02/2009 Day Telephone: (325) 695 -1090 TX 79606 State Zip Page 2 of 2 Parcel No.: 2716000020 Address: 12682 GATEWAY DR TUKW Suite No: Applicant: VERIZON BUSINESS Receipt No.: R09 -01082 Initials: WER User ID: 1655 Payee: MCKINSTRY • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 296359 2,599.20 Authorization No. ACCOUNT ITEM LIST: Description MECHANICAL - NONRES RECEIPT Account Code Current Pmts 000.322.102.00.0 2,599.20 Total: $2,599.20 Permit Number: M09 -013 Status: APPROVED Applied Date: 02/05/2009 Issue Date: Payment Amount: $2,599.20 Payment Date: 07/14/2009 10:04 AM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 07 -14 -2009 Copy Reprinted on 02 -05 -2009 at 11:05:20 02/05/2009 RECEIPT NO: . R09 -00202 Initials: JEM User ID: 1165 Total Payment: 8,653.42 Payee: WTA, INC. SET ID: S000001171 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D09 -015 EL09 -0101 M09 -013 TOTAL: 6,220.37 1,783.25 649.80 6,220.37 TRANSACTION LIST: Type Method Description Amount Payment Check 8629 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES City of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT TOTAL: Payment Date: 02/05/2009 8,653.42 8,653.42 Account Code Current Pmts 000.345.832.00.0 1,783.25 000/345.830 6,870.17 TOTAL: 8,653.42 Project:, Ye'✓iyOA/ Type of Inspection: F n/,g/ Address: /-2_b F32 (/ew4 y Date Called: c0,''. Special Instructions: Date Wanted: a.m: .06_05 p.m. Requester: Phone No: .20a- 7,-, CITY OF TUKWILA BUILDING DIVISION Ap proved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPE� NO. PERMIT N 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 El Corrections required prior to approval. COMMENTS: -14- Inspecto .00 REINSPECTION FEQ REQUIRE ,p. Prior to inspection, fee must be aid at 6300 Southcenter B d., Suite 100. Call to schedule reinspection. Receipt No.: Dat Date: Proje t: o f . ' ? .» A ■ &US A e Si SJ Type o nspection: e ..:t...,/� f o Ad Date Called: In / Date Wanted: / (/ ' Jq „ p.m. Requester: Phone No: 503 -4 — /t9°2 - INSPECTION RECORD Retain a copy with permit Mod -o13 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431j3 rc 70 .COl IM ENTS: specto id at 6300 Southcenter ceipt No.: tA ,.�/C( 0 REINSPEC IO FEE MIRED d., Suite Dates rior to inspection, fee must be 0. Call to schedule reinspection. Date: Approved per applicable codes. Corrections required prior to approval. Pro�ec � /i ye iV 12T/S,n/,-s5 Type of Inspection: . A? 4?)/ � i '1/ .J Address: /.2.6 8Z , /cy Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: a a C -zs- -d96 / INSPECTION RECORD Retain a copy with permit INSPEcTION NO. PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION 14 ' 6300 Sputhcenter Blvd., #100, Tukwila, WA 98188 ' (206)431 -367 Approved per applicable codes. Corrections required prior to approval. MENTS: 60. ' REINSPECTION FE REQUIRED. Pj ior to inspection, fee ' ust be al • at 6300 South enter B vd., Suite 10Q' Call to schedule reinspection. 'Date: 1 1 COMMENTS: / C - 0,x, / / ,1 Q (irk t., ..1r 1(G ` . ) 4._ i a ef *. re% --- - c..1(I 6 et ()( re— ,aS n P c..P liA Special Instructions: ifEj )01)(J — AfrA Requester: r -/V7� Project: / / . 9 A / $ ( 4 7 7 1 4 5 :' Type of Inspection: ,Q h - /Iv s, --d i Address: V15 . /vo Date Called: Special Instructions: Date Wanted: Requester: Phone No: _ Zc' - z27 -/V7� #I INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 El Approved per applicable codes. 4 09, a 8 -a.3 Corrections required prior to approval. Inspector: J1 Date: - 1 —I ` f El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: V i7o Sprinklers: Type of :nspection: P I Hood & Duct: Address: 1 ( 465? Suite #: . 4.‘,Ivitt,,' `b2_ Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Approved per applicable codes. 140q 0(3 1.5t7 ,1 f PERMIT NUMBERS n Corrections required prior to approval. COMMENTS: c-7 lc Inspector: A, y Pi-A/1ff' $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. I Date: Hrs.: Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project Info Project Address 12682 Gateway Drive South Date 2/2/2009 Tukwila, WA 98168 For Building Department Use Applicant Name: K. Craig Manawes, PE Applicant Address: One village Drive, Suite 500, Abilene, TX 79606 Applicant Phone: 325- 695 -1090 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM FILE COPY Permit No. Plan review approval is ruhlect to errr.lc find omis sion s. s I S MPLIANCE EVE® FEB 1 q 7009 Revised July 2007 RECEIVED CITY OF TUKWLA FEB 0 5 /009 PERMIT CENTER JIO'oL3 Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location For Building Dept. Use Applicant Name: K. Craig Manawes, PS Applicant Address: One Village Drive, Suite 500, Abilene, TX 79606 Applicant Phone: 325- 69s -1090 Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM SP' HP /BHP Flow Control Location of Service Efficiency For Building Dept. Use Applicant Name: K. Craig Manawes, PS Applicant Address: One Village Drive, Suite 500, Abilene, TX 79606 Applicant Phone: 325- 69s -1090 Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency For Building Dept. Use Applicant Name: K. Craig Manawes, PS Applicant Address: One Village Drive, Suite 500, Abilene, TX 79606 Applicant Phone: 325- 69s -1090 Project Info Project Address 12682 Gateway Drive South Date 2/2/2009 Tukwila, WA 98168 For Building Dept. Use Applicant Name: K. Craig Manawes, PS Applicant Address: One Village Drive, Suite 500, Abilene, TX 79606 Applicant Phone: 325- 69s -1090 Mechanical Su - mmary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Indudes Plans 2006 Washington State Nonresidential Energy Code Compliance Form 'If available. 2 As tested accord ng to Table 14 -1A through 14-1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Revised July 2007 Project includes installation of (4) 30 -ton Computer room air conditioning units, (1) 163 -ton air cooled packaged chiller, (1) 15 -HP chilled water pump and associated chilled water piping. Project will also include relocation of existing chilled water piping and relocation of (1) existing 30 -ton CRAC unit. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option 0 Simple System ® Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: ❑ <5000 cfm? o ❑ <70% outside air? Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only 2006 Washington State Nonresidential Energy Code Compliance Form Simple System Allowed (section 1420) otal Ca.. wo economize <240,000 Btuh or 10 %7 Reference Section 1421 Yes — Yes* Heating /Cooling or Cooling Only Yes Yes Reference ` Section 1423 • Yes Yes Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical - Complex 2006 Washington State Nonresidential Energy Code Compliance Forms Systems Checklist MECH -COMP Revised July 2007 Project A dd r e ss 12682 Gateway Drive South Date 2/2/2009 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH- CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY n.a. 1431.1 Field assem. sys. Provide calculations yea 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans M -3,M- 4,M -7,M• 8 n.a. 1432.2.1 Air system reset Indicate automatic reset yes 1432.2.2 Hydronic System Indicate automatic reset, cooling tower, & heat pump loop valves M -5, 14- 6 n.a. 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. n.a. 1433 Water Economizer Indicate water economizer and provide calculations if 1433 Exception 2 is utilized yes 1434 Separate air sys. Indicate separate systems on plans M -3, M- 4 n.a. 1435 Simul. htg. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified n. a. 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations yes 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency M n.a. 1438 Variable flow sys. Indicate variable flow on fan and pump schedules n.a. 1439.1 Kitchen Hoods Indicate uncooled and unheated make -up air n.a. 1439.2 Fume Hoods Indicate VAV, unheated /uncooled or heat rec. makeup Start Here • Section 1411.1 Equipmen Efficiency Shall Meet Tables 14 -1A through 14 -1G Yes • 1411.1 Intermittent Ignition Device & Power Venting or Damper. If input 225,000 Btuh then 1412.6 Modulating or Staged Combustion Controls Required 2006 Washington State Nonresidential Energy Code Compliance Form no is circiea Tor any question, proviae explanation: Decision Flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. as/Oil Fuma input ? 225,000 tuh or Gas/O' t Heat Air System Serving Multiple Zones? apacity of H Heating System > 00,000 Btuh Yes • 1411.1 0.75% Maximum Jacket Loss Yes Section 1431.1 Calculations of Total On -Site Energy Input & Ouput Required (continued on back) Yes Section 1432.2.1 Supply Air Reset Controls Required Yes No Section 1432.2.2 Hot Water Supply Temperature Reset Required 2006 Washington State Nonresidential Energy Code Corr Nance Forms Yes 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical o Complex Systems (back) MECH -COMP 0% Air Eton Provided? Section 1413 Water Cooled wNVater Econo? otal Clg Capacity w/ Water Econo <500 Tons pply Air >5,0 cfm &OSA> 70% otor m ci. I qpmt. Covrd by Tbl 14- 1A -14- 1G? EER 10% Better than Code Section 1436 50% Effective Heat Recovery Required 0 Yes Yes Yes No No DONE I Yeses Multi -speed Motor in Multi - eed system Yes-* Yes tal Cap cono <= 480,00 Btuh or 20% of otal Cap. Yes Section 1435 Zone Controls Must Reduce Supply Air Quantity Before Reheating /Recooling Section 1439.1 No Heating or Cooling for at Least 50% of Make -up Air 0 No--* V Section 1433 Economizer Required Yes stem or Zon w/ Simultaneous Htg. & Clg.? Section 1437 Motors Must Meet Efficiencies in Table 14-4 Yes Application Involves Variable Flow? Section 1438 Variable Flow Devices Required Yes Section 1439.2 One Required: a. 50% VAV Exhaust & Make -up b. 75% Direct Makeup w/ Tempering Only c. Heat Recovery per 1436 d. Constant Volume w/ < 50fpm Face Velocity Yes Revised July 2007 Open Motors Closed Motors 3,600 1,800 1,200 3,600 1,800 1,200 Efficiency ( %) Efficiency ( %) - 82.5 80.0 75.5 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 92.4 91.7 91.0 92.4 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 93.0 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93.0 94.1 93.6 93.0 94.1 93.6 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 9a6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95.0 Electric Motors M EC H -M 2006 Washington State Nonresidential Energy Code Compliance Forms Project Address Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). Motor No. or Location CW Pump 3- 08 Chiller 3- 08 CRAC 16 CRAC 18 CRAC 23 CRAC 25 Synchronous Speed (RPM) HP 1.0 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 15 2 15 15 15 15 HP 2006 Washington State Nonresidential Energy Code Com.liance Form 12682 Gateway Drive South Type (open/closed) closed closed closed closed closed closed Minimum Nominal Full -Load Efficiency Description of Application or Use Chilled Water Pump motor Air Cooled Pkg. Chiller Computer Room Air Conditioner Evaporator Fan Motor Computer Room Air Conditioner Evaporator Fan Motor Computer Room Air Conditioner Evaporator Fan Motor Computer Room Air Conditioner Evaporator Fan Motor Date For Building Department Use Synch. Speed 1800 1800 2/2/2009 Revised July 2007 Min.Nom. Full load Efficiency 70.0% Exception No. 2 1800 Exception No. 2 1800 Exception No. 2 1800 Exception No. 2 1800 Exception No. 2 Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- 1Aor14 -1B). 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. Mechanical Permit Plans 2006 Washington State Nonresidential Energy Code Compliance Forms Checklist MECH -CHK Revised July 2007 Project Address 12682 Gateway Drive South 'Date 2/2/2009 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance yes 1411.4 Pkg. elec. htg.& cig. List heat pumps on schedule M -3, M- yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M -9 n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans M -3, M- n. a. 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat no 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types Expt 1 n.a. 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control n.a. 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans n.a. 1423 Economizers Equipment schedule 1413 Air economizers n.a. 1413.1 Air Econo Operation Indicate 100% capability on schedule n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & cig tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems n.a. 1414.1 Duct sealing Indicate sealing necessary n.a. 1414.2 Duct insulation Indicate R -value of insulation on duct yes 1415.1 Piping insulation Indicate R -value of insulation on piping 15083 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan 15734 yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing 15950 yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training 15734 yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report 15734 yes 1434 Separate air sys. Indicate separate systems on plans M -3, M- Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank n.a. 1442 Shut -off controls Indicate automatic shut -off n.a. 1443 Pipe Insulation Indicate R -value of insulation on piping n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form no is circles for any question, proviae explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an Intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper Is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving . conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. c. Automatic modulating control of the outdoor air damper, or A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Alr Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an Intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper Is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving . conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. c. Automatic modulating control of the outdoor air damper, or A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Alr Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying Vu1IC10 Ill 1110 11101 dul allu ICVCIO IJCIVW 1110 11101 01V1 y ul uullu11190 ^ - ^"-"- -•^ - ^•• ^• ^ ^• ^^ ��•• ^'••0 ^•• ^r -""' - " - i1 three or more stories in hehb6 Washington State Nonresidential Eher§9netsio thrlimer or 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum with Section 1412.4.1. start controls shall be designed to automatically adjust the start time of an HVAC Once outside air ducts meet the above listed requirements, any runs within system each day to bring the space to desired occupied temperature levels conditioned space shall comply with Table 14 -5 requirements. immediately before scheduled occupancy. The control algorithm shall, as a Other ducts and plenums shall be thermally insulated per Table 14 -5. minimum, be a function of the difference between space temperature and occupied Exceptions: setpoint and the amount of time prior to scheduled occupancy. 1. Within the HVAC equipment. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- 2. Exhaust air ducts not subject to condensation. up, and defrost conditions. These controls shall anticipate need for heat and use 3. Exposed ductwork within a zone that serves that zone. compression heating as the first stage of heat. Controls shall indicate when 1415 Piping Systems supplemental heating is being used through visual means (e.g., LED indicators). 1415.1 insulation: Piping shall be thermally insulated in accordance with Table 14 -6. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment Exception: Piping installed within unitary HVAC equipment. with a capacity over 225,000 Btu /h shall have modulating or staged combustion Water pipes outside the conditioned space shall be insulated in accordance with . control. 000 Washington State Plumbing Code (WAC 51 -26) EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1416 Completion Requirements (Refer to NREC Section 1416 and the Building 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have Commissioning Guidelines, published by the Building Commissioning Association, a means for balancing, including but not limited to, dampers, temperature and for complete text and guidelines for building completion and commissioning pressure test connections and balancing valves. requirements.) 07 -02 -2009 K. CRAIG MANAWES, PE ONE VILLAGE DR, STE 500 ABILENE TX 79606 Dear Permit Applicant: City of Tukwila RE: Permit Application No. M09 -013 12682 GATEWAY DR TUKW Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 02/05/2009, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 08/04/2009. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, - Bill Rambo Permit Technician File: Permit File No. M09 -013 R ?nn C.,..rR. *.,.. 1:?.,•11.........4 C.. ;a.. 441n/1 T..1..., ;1. ry ...;.:. _. _ onion - nn____ nn ..-, •e _ ACTIVITY NUMBER: M09 -013 DATE: 02 -05 -09 PROJECT NAME: VERIZON BUSINESS SITE ADDRESS: 12682 GATEWAY DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: I1A-V Bui 'vision Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY r PLAN REVIEW /ROUTING SLIP ❑ Structural u AvN(/ Fire Prevention Incomplete Structural Review Required n L Approved with Conditions Planning Division Permit Coordinator n n DUE DATE: 02-09-09 Not Applicable No further Review Required n DATE: DUE DATE: 03-09-09 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Name Role Effective Date Expiration Date PEDERSEN, JAMIE D AGENT 03/16/2006 Status ALLEN, DEAN C PARTNER /MEMBER 03/16/2006 GENERAL MOORE, DOUGLAS J PARTNER /MEMBER 03/16/2006 ARCHIVED ALLEN, DAVID E PARTNER /MEMBER 03/16/2006 GENERAL TEPLICKY, JOSEPH PARTNER /MEMBER 03/16/2006 REREGISTERED License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WESTVI' 121 RF WESTVENT INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 12/6/1988 9/1/1994 ARCHIVED MCKIN" "372ND MCKINSTRY CO CONSTRUCTION CONTRACTOR GENERAL UNUSED 8/20/19631 /2/2008 REREGISTERED Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 TRAVELERS CAS Et SURETY CO 104702039 01/03/2006 Until Cancelled $12,000.00 03/16/2006 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L@I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MCKINSTRY CO LLC 2067623311 PO BOX 24567 SEATTLE WA 98134 KING Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602569922 ACTIVE MCKINCL942DW CONSTRUCTION CONTRACTOR 3/16/2006 3/16/2010 GENERAL UNUSED Other Associated Licenses Business Owner Information Bond Information Insurance Information • • Page 1 of 2 https: // fortress .wa.gov /lni/bbip/Detail.aspx 07/14/2009 MATCHLINE FUTURE PANEL "DP4 �AGB -1 ErXla;,'r1Nc E(UI r DGGB -2 EXISTING CONDITIONS NOTE :_ 1, EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. N FAA/ SECURITY ROOM BRGB -t 0 DGGB -1 FUTURE NEW PANELBOARD PANEL DP3A" DP2B' — i L_____ t771 2 f 4 _......_ a ___.__.......__.. ANALASER \ --FGB -1 ZONE 3 BOX REFER TO P -3 FOR CONTINUATION GENERAL NOTES: 1. ALL PIPING SHOWN ARE LOCATED BELOW RAISED ACCESS FLOOR. 2. RAISED ACCESS FLOOR NOT SHOWN FOR CLARITY. 3. AFTER ALL WORK IS COMPLETE, CONTRACTOR SHALL REMOVE ALL CONSTRUCTION TRASH AND DEBRIS AND VACUUM CONCRETE SURFACE BELOW RAISED FLOOR TO INSURE ENTIRE AREA BELOW RAISED FLOOR IS LEFT CLEAN AND DUST FREE. IGW LINE IS CONTINUED ON SHEET P -3 SCALE: 1/4" v 1' -0" PANEL "BPPA2" PANEL "CRPPAI" r W D U F—� W U T 4 EX. FD I Li al 04 u. PANEL "CRPPBI" r' r I'`L:VV FL,.00R PARTIAL FIRST FLOOR PLAN - PLUMBING -NORTH NOTES INDICATED BY NUMBER IN 1 REMOVE EXISTING HUMIDIFIER WATER MAKE -UP LINE TO CRAG #11 BACK TO HUMIDIFIER WATER MAIN AND CAP. 2. PROVIDE NEW 1/2" HUMIDIFIER WATER MAKE -UP CONNECTION TO MAIN, EXTEND TO EXISTING CRAC #11 AS INDICATED, AND CONNECT TO UNITS HUMIDIFIER WATER MAKE -UP CONNECTION. 3. CUT A PORTION OF EXISTING PIPING AT THE LOCATION AND INSTALL A NON- CONDUCTIVE SECTION. REFER TO DETAIL, THIS SHEET. REFER TO ARCHITECTURAL PLANS FOR DETAIL OF PIPE PENETRATION THRU WALL. PANEL .... "ULPP1 -1" XFMR LITRL1 -1 ANA LASER ZONE 4 BOX- T NEW SOLDER EXISTING PIPE INSULATION EXISTING COPPER TUBING NEW PIPE INSULATION NO SCALE BATTERY 1D BATTERY 1C REFER TO P -3 FOR CONTINUATION INSTALL WITHIN 6" FROM WALL NEW NEW SCHEDULE 80 / SOLDER � PVC UNION 1" ANNULAR SPACE W/ 1" DEPTH 3M FIRE BARRIER CP 25WB +CAULK EQUIPMENT ROOM BATTERY 1B M09 BATTERY IA UPS -1 013 1" ANNULAR SPACE W/ MINERAL —WOOL PACKING EXISTING COPPER TUBING EXISTING PIPE INSULATION CORRIDOR WATER PIPE WALL PENETRATION DETAIL CODE COVVLIPACE APPROV o froila japoGovisi RECEIVED CITY OF TUKWILA FEB 0 5 ?MN PERMIT CENTER WTA - 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS Ill CJ ti r. LLrr \G M,/,,v ' g. : Y c i \\•••••°°°°#° AT EC2U/PMENT ROOM BULDO T s v .�_ s! � ® ® _vim► _ _ _ _ - - - - Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj, Mgr.: KCM Date: 12 -12 -08 Revision 1 01 -05 -09 95% REVIEW 2 01 -15 -09 100% CD 3 01 -26 -09 ADD. NO. 1 4 02 -02 -09 PERMIT SET Project No, WTA. 08093 Sheet No. P-4 PARTIAL FIRST FLOOR PLAN - PLUMBING - NORTH MATCHLINE FUTURE PANEL "DP4 �AGB -1 ErXla;,'r1Nc E(UI r DGGB -2 EXISTING CONDITIONS NOTE :_ 1, EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. N FAA/ SECURITY ROOM BRGB -t 0 DGGB -1 FUTURE NEW PANELBOARD PANEL DP3A" DP2B' — i L_____ t771 2 f 4 _......_ a ___.__.......__.. ANALASER \ --FGB -1 ZONE 3 BOX REFER TO P -3 FOR CONTINUATION GENERAL NOTES: 1. ALL PIPING SHOWN ARE LOCATED BELOW RAISED ACCESS FLOOR. 2. RAISED ACCESS FLOOR NOT SHOWN FOR CLARITY. 3. AFTER ALL WORK IS COMPLETE, CONTRACTOR SHALL REMOVE ALL CONSTRUCTION TRASH AND DEBRIS AND VACUUM CONCRETE SURFACE BELOW RAISED FLOOR TO INSURE ENTIRE AREA BELOW RAISED FLOOR IS LEFT CLEAN AND DUST FREE. IGW LINE IS CONTINUED ON SHEET P -3 SCALE: 1/4" v 1' -0" PANEL "BPPA2" PANEL "CRPPAI" r W D U F—� W U T 4 EX. FD I Li al 04 u. PANEL "CRPPBI" r' r I'`L:VV FL,.00R PARTIAL FIRST FLOOR PLAN - PLUMBING -NORTH NOTES INDICATED BY NUMBER IN 1 REMOVE EXISTING HUMIDIFIER WATER MAKE -UP LINE TO CRAG #11 BACK TO HUMIDIFIER WATER MAIN AND CAP. 2. PROVIDE NEW 1/2" HUMIDIFIER WATER MAKE -UP CONNECTION TO MAIN, EXTEND TO EXISTING CRAC #11 AS INDICATED, AND CONNECT TO UNITS HUMIDIFIER WATER MAKE -UP CONNECTION. 3. CUT A PORTION OF EXISTING PIPING AT THE LOCATION AND INSTALL A NON- CONDUCTIVE SECTION. REFER TO DETAIL, THIS SHEET. REFER TO ARCHITECTURAL PLANS FOR DETAIL OF PIPE PENETRATION THRU WALL. PANEL .... "ULPP1 -1" XFMR LITRL1 -1 ANA LASER ZONE 4 BOX- T NEW SOLDER EXISTING PIPE INSULATION EXISTING COPPER TUBING NEW PIPE INSULATION NO SCALE BATTERY 1D BATTERY 1C REFER TO P -3 FOR CONTINUATION INSTALL WITHIN 6" FROM WALL NEW NEW SCHEDULE 80 / SOLDER � PVC UNION 1" ANNULAR SPACE W/ 1" DEPTH 3M FIRE BARRIER CP 25WB +CAULK EQUIPMENT ROOM BATTERY 1B M09 BATTERY IA UPS -1 013 1" ANNULAR SPACE W/ MINERAL —WOOL PACKING EXISTING COPPER TUBING EXISTING PIPE INSULATION CORRIDOR WATER PIPE WALL PENETRATION DETAIL CODE COVVLIPACE APPROV o froila japoGovisi RECEIVED CITY OF TUKWILA FEB 0 5 ?MN PERMIT CENTER WTA - 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS MATCHLINE E JE I :;Ti NG s: i ldl MEN =F [DPhil EXISTING CONDITIONS NOTE: REFER TO P -4 FOR CONTINUATION 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. GENERAL NOTES: SCALE: 1/4" = 1' -0" 1. ALL PIPING SHOWN ARE LOCATED BELOW RAISED ACCESS FLOOR. 2. RAISED ACCESS FLOOR NOT SHOWN FOR CLARITY. 3. AFTER ALL WORK IS COMPLETE, CONTRACTOR SHALL REMOVE ALL CONSTRUCTION TRASH AND DEBRIS AND VACUUM CONCRETE SURFACE BELOW RAISED FLOOR TO INSURE ENTIRE AREA BELOW RAISED FLOOR IS LEFT CLEAN AND DUST FREE. LINE IS CONTINUED ON SHEET P -4 1-1/2" - 1 -1/4" KI 1 -1/2" 0 II —J I1 / I I _ J II 1 11 1 II 1 z w 1 ca I I I / 1 I 1 I 1 I 1 . C14}. -1- L 1=.: I1 V 1 1 -1/4" CD — 1 - 1/4" CORRIDOR N ay I.d ": UI r'IVI [ N 1 PARTIAL FIRST FLOOR PLAN — PLUMBING — SOUTH NOTES INDICATED BY NUMBER IN (: 1. CONNECT 1 -114" CONDENSATE DRAIN LINE TO NEW CRAC UNITS CONDENSATE DRAIN CONNECTION AND EXTEND TO EXISTING FLOOR DRAIN AS INDICATED. 2. TERMINATE NEW CONDENSATE DRAIN LINES; AT EXISTING FLOOR DRAIN BELOW RAISED ACCESS FLOOR. 3. RELOCATE EXISTING CONDENSATE DRAIN LINE CONNECT TO RELOCATED CRAG #26. 4. RELOCATE EXISTING HUMIDIFIER WATER MAKE TO CONNECT TO RELOCATED CRAG #26. AS REQUIRED TO UP LINE AS REQUIRED .21Il_: "_:iu:` ::::::;::1,r: REFER TO P -4 FOR CONTINUATION u I109 - 6l3 Wl. CODE COVIKINCE. APPIWI r OiTuVa pi la �G 0 SIO'� Cpl MATCHLINE Ei RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT a 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 3 01 -05 -09 01 -15 -09 01 -26 -09 02 -02-09 ■ p1; ":S d I/ le) I itJ M m W u1 m " D an X X t % E W n u F. Z w i W m r" ZW N or 04". co ° c Q () 4.1 vc co in c (i) (f) p Fac. Code:TYKWWA Drawn By: IM PS, ZJ Designed By: KCM DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision Sheet No. 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 PARTIAL FIRST FLOOR PLAN - PLUMBING - SOUTH PACKAGED AIR CONDITIONING UNIT SCHEDULE CONTRACTOR INSTALLED) UNIT NO TOTAL AIR CFM EXT. STATIC IN, WATER AIR FLOW EVAP. F FAN - ELEC. REHEAT - _ HUMIDIFIER - COOLING DATA CONDENSER SECTION COMPRESSORS CHILLED WATER SECTION COILS FACE AREA /ROWS TOTAL UNIT FLA EQUAL TO H.P. H.P, VOLTS PHASE TYPE PACITY MBH TYPE CAPACITY LBS /HOUR ENT, AIR F CAPACITY MBH ENT, WTR_ TEMP, °F FLOW RATE P M PRESS. DROP PSI NO. FLA EA. VOLTS PHASE ENT, INTR. TEMP, °F FLOW RATE GPM PRESS, P DROP PSI E AP V CHILLED WATER DB WB TOTAL SENSIBLE 11 12,400 0.5 DOWN 10 460 3 ELEC 121.5 INFRARED 22.1 72 60 328.4 274.2 54 ° ' - R -134a 1 c 159, 1 c 105 8 @ 2.8 EACH 45 65.6 8.4 460 25/6 80 LIEBERT FH529C -AAEI EXIST, 12 _ _ _ _ - - - - - - - - - - - _ - - - _ ° - _ - - FUTURE 13 12,400 0,5 DOWN 10 460 3 ELEC 121,5 INFRARED 22,1 72 60 328,4 274,2 _ _ _ _ _ " 45 65.6 8.4 " 25/6 80 LIEBERT FH529C -AAEI EXIST, 14 _ _ _ _ _ T _ _ _ - _ _ _ _ _ - _ - _ - - - _ - - - - - - FUTURE 15 12,400 0.5 DOWN 10 460 3 ELEC 121.5 INFRARED 22,1 72 60 328.4 274.2 - " - ' 45 65.6 8,4 25/6 80 LIEBERT FH529C -AAEI EXIST, 16 12,400 0.5 DOWN 15 460 3 — — 72 60 327.0 267.0 7.,a� �_ 42 _ 59.0 $.4 25/6 14 ! LIEBERT FH529C -AA00 NEW 17 12,400 0,5 DOWN 10 460 3 ELEC 121.5 INFRARED 22,1 72 60 328,4 274,2 " _ " - " 45 65:6 8,4 25/6 80 LIEBERT FH529C -AAEI EXIST, 18 12,400 0,5 DOWN 15 460 3 72 _ 60 - 327,0 _ 267,04 - - W 4P:. - _ -44111 - 42 _ 59,0 _ 8.4 _ 2516 14 LIEBERT FH529C -AA00 NEW FUTURE 1 _ - _ - _ _ _ _ 20 12,400 0,5 DOWN 460 3 ELEC 121.5 INFRARED 22.1 72 60 328.4 274.2 - " - 45 65.6 8,4 ° 25/6 80 LIEBERT FH529C -AAEI EXIST, 21 - - _ - _ _ _ - _ _ _ _ r _ _ _ _ _ - - - - _ _ - - - - FUTURE 22 12,400 0.5 DOWN 10 460 3 ELEC 121,5 INFRARED 22,1 72 60 328,4 274.2 _ - ' 45 65,6 8.4 _ 25/6 80 LIEBERT FH529C -AAEI EXIST. 23 12,400 0,5 DOWN 15 460 3 72 60 327,0 267,0 � � ��� �� 42 59,0 8,4 `--. 25/6 14 LIEBERT FH529C -AA00 NEW 24 12,400 0.5 DOWN 10 460 3 ELEC 121.5 INFRARED 22.1 72 60 328.4 274.2 " - _ 45 65.6 8.4 25/6 80 LIEBERT FH529C -AAEI EXIST. 25 12,400 0.5 DOWN 15 460 3 ." 72 60 327.0 267.0 _ /1 42 59.0 8.4 25/6 14 LIEBERT FH529C -AA00 NEW 26 12,400 0.5 DOWN 10 460 3 ELEC 121.5 INFRARED 22.1 72 60 328,4 274,2 I.1 - ' _ 45 65,6 8,4 _ 25/6 80 LIEBERT FH529C -AAEI EXIST, AIR COOLED P PUMP DESIGNATION GPM CHILLER SCHEDULE (OWNER FURNISHED CONTRACTOR INSTALLED) UNIT DESIG, CHILLER CAPACITY CONDENSING UNIT CAPACITY REMARKS GPM ENT. T. °F LVG. T. °F MAX P.D, FT. WATER SCALE FACTOR REFRIG. COMPRESSOR F.L.A. FAN F.L.A. ENTERING AIR TEMP. °F EER IPLV VOLTS PHASE 1 - 08 365 54 42 22.0 0.00010 R -22 1 c 140, 1 c 128 8 © 4.0 EACH 95.0 EX. EX. 460 3 EQUAL TO YORK #YCS0170EC46XFA EXISTING, NOTE 1,2 2 -08 365 54 42 22.0 0.00010 R -22 1 @ 140, 1 c 128 8 @ 4,0 EACH 95.0 EX. EX. 460 3 EQUAL TO YORK #YCS0170EC46XFA EXISTING, NOTE 1,2 3 -08 365 54 42 17.8 0.0005 R -134a 1 c 159, 1 c 105 8 @ 2.8 EACH 95.0 9.4 14.8 460 3 EQUAL TO YORK #YCIV0177PA46 NEW CHILLER CHILLED WATER PUMP SCHEDULE PUMP DESIGNATION GPM HEAD FT. WATER MIN. EFF, TYPE OF PUMP SPEED RPM MIN. H P. VOLTS PHASE MANUFACTURER NO OR APPROVED EQUAL 1 -08 365 100 END SUCTION - CENTRIF, 1750 5 480 3 TACO FE3010 (EXISTING) 2 -08 365 100 END SUCTION- CENTRIF. 1750 ' 5 480 3 TACO FE3010 (EXISTING) 3 -08 365 100 70% END SUCTION - CENTRIF, 1750 ' 5 480 3 TACO FI3011 (NEW) NOTES: 1, NEW UNIT SHALL BE FACTORY EQUIPPED WITH 27" SEISMIC RATED FLOOR STAND, FLOOR STAND TURNING VANE ASSEMBLY, SMOKE DETECTOR, ADVANCED MICROPROCESSOR CONTROL, WATER DETECTION SYSTEM LIEBERT NO, LT460Z45, AND OTHER ACCESSORIES AS SPECIFIED, 30% EFFICIENCY FILTERS, CONNCT NEW LINES TO EXISTING BAS SYSTEM. NOTES: . ADJUST CONTROLS OF EXISTING PACKAGED AIR COOLED CHILLER TO DELIVER 44 ° F LEAVING WATER TEMPERATURE WITH AN ENTERING WATER TEMPERATURE OF 54 °F. . VERIFY EXISTING EVAPORATOR THERMOSTATICALLY CONTROLLED HEATER ARE IN GOOD ORDER AND FULLY OPERABLE, 3 SCALE: 1/2" = 1' -0" NO SCALE WELD 360 DEGREES NOTE: PROVIDE DESIGN /CALCULATIONS AND SHOP DRAWINGS FOR PIPE SUPPORT, INCLUDING WELDING CALCULATIONS AND DETAILS BY LICENSED STRUCTURAL ENGINEER, TYPICAL FOR ALL PIPE AND EQUIPMENT SUPPORTS. NO SCALE .N4t/MbidiEsfil. ?UMW ROM 411gr z iii d u�a x t� u r o t�sn z ar sr m r rr u r n r a t na f 'C,Pt'A irid& DRIP ENCLOSURE DETAIL 18 GA. GALV SLEAVE 12" LONG STD, U —BOLT PROVIDE 24V. AC AUXILIARY CONTROL POWER FROM CRAC UNIT NO C NC; GALVANIZED STEEL TUBE GALVANIZED ANCHOR AND BOLT (TYP 4 PER PLATE) - GALVANIZED STEEL PLATE r CRAC UNIT'S SPECIAL ALARM CONNECTION PROVIDE WATER LEAK DETECTION MODULE, LIEBERT NO. LT 460Z45 COMPLETE WITH SENSING CABLE CABLE END TERMINATOR WATER LEAK SENSING CABLE SERPENTINED IN DRIP PAN BENEATH CRAC UNIT TYPICAL WATER DETECTION SYSTEM WIRING DIAGRAM FOR DRIP PAN RAISED) FLUOR C(2)NO, FLOOR c Ogal e C1� NOTES INDICATED BY NUMBER IN 0: 1. MO9 l 3 INSULATION WITH ALUMINUM JACKET PROVIDE 18 GA. GALVANIZED STEEL SADDLE 12" LONG TYPICAL EXTERIOR PIPE SUPPORT DETAIL RECEIVED CITY OF TUKWLA FEB 0 5 2009 PERMIT CENTER CONTRACTOR SHALL INSTALL A WATER TIGHT DRIP ENCLOSURE BELOW EXISTING CRAC UNITS. ENCLOSURE TO BE CONSTRUCTED OF 18 GAUGE GALVANIZED STEEL ANGLES WITH WELDED OR SOLDERED JOINTS. ENCLOSURE SHALL BE 2" DEEP AND EXTEND BEYOND THE PERIMETER OF THE EXISTING CRAG FLOOR STAND. TOP EDGES SHALL BE HEMMED OR ROLLED FOR SAFETY. 2. CONTRACTOR SHALL INSTALL WATER LEAK DETECTION CABLE SERPENTINED IN DRIP PAN ENCLOSURE BELOW CRAC UNIT. CONNECT THE WATER LEAK DETECTION SYSTEM TO THE CRAC CUSTOM ALARM TERMINALS AS INDICATED BY DETAIL 2, THIS SHEET. 3. MASONRY BOLTS ANCHORED TO CONCRETE FLOOR AT CORNERS AND MID POINTS NOT MORE THAN 18" ON CENTER MAXIMUM DISTANCE APART. 4. 2 "x2" 18 GAUGE GALVANIZED STEEL ANGLE SET ON BED OF SEALANT. WTA — 08093 COPYRIGHT 002009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 L. Fac. COde:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj, Mgr,: KCM Date: 1212 -08 Revision 01 -05 -09 01 -15 -09 01 -26 -09 02-02-09 Project No. WTA. 08093 Sheet No. M -9 HVAC SCHEDULES Z20 o c l ce uc k (I) L *( .‹c (i) 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET VEIN MN MIMII 11111111•11111 CRAC CHILLED WATER COIL CHILLED WATER VALVE CONTROL ACTUATOR, PROVIDED WITH UNIT 2 -WAY CHILLED WATER CONTROL VALVE, PROVIDED WITH UNIT CONNECT NEW 2" RUNOUT PIPING TO CRAC UNIT FOR EXISTING TAPS, REMOVE CAP AND CONNECT NEW 2" CHILLED WATER TO EXISTING 2" VALVE CHS TYPICAL CRAC UNIT - FRAME FRONT REFERENCE TEMPERATURE AND PRESSURE TEST PART BALANCING VALVE, CIRCUIT SETTER TYPE - CHR TYPICAL CHILLED WATER CONNECTION TO NEW CRAC UNIT NO SCALE NOTE: PROVIDE DIELECTRIC FITTINGS WHERE CONNECTING DISSIMILAR PIPING MATERIALS AND METALS. 1. 10' 0 "O.C. 0 6" CHWS &CHWR NOTES INDICATED BY NUMBER IN 1 % " UNITSTRUT, TYPICAL. 3. 4 "X4 "X1/4" THICK PLATE . SCALE: AS INDICATED SIDE VIEW SCALE: 1/2" =1 2. DRILL THRU PLATE % "0 AND INSTALL % "0 X 2 Y2" LONG CONCRETE BOLTS AND SLEEVES. (4 PLACES) TYPICAL. 4. FABRICATE CLAMP FROM Y8" THICK X %' WIDE METAL CLAMP /BAND. BOLT TO UNISTRUT. 5. SHEET METAL SADDLE (TYPICAL). 6. 6" CHS & CHR PLUS 2" OVERALL INSULATION. 10'-0"0.C. TYPICAL UNDERFLOOR CHILLED WATER LOOP PIPE RACK DETAIL SCALE: 1" = 1' -0" :tY`...y-- ...._�_�..':..,-._. .._ _ � • K •-- 4 '� -}- l' : LL "`:tl " ._i.i:3,. ���a..'.e �...Mt i..... ...t....(t. «._:... -. il15:1':t ' ..r •• r r- -_r'..r- ; � -. _rr•zr. --�_ . . ,...- r,:r- a- .'_r.r..- "'r. - -.... r .�: ,-.. - r:: _T__. ... ... ,, _ FRONT VIEW RAISED ACCESS FLOOR FIN. FLOOR SECTION SCALE: 1/2" =1 NOTES INDICATED BY NUMBER IN 0: I. EXISTING CHILLED WATER SUPPLY AND RETURN LOOP. 2. EXISTING 2" TAP WITH VALV AND CAP. 3. EXTEND 1 -1/4" INSULATED CONDENSATE DRAIN LINE TO NEAREST FLOOR DRAIN. 4. CONNECT RUNOUT PIPING TO UNIT. REFER TO UNIT CONNECTION DETAIL, THIS SHEET. FACTORY PIPES INSIDE UNIT, NEW 2" COPPER RUNOUT WITH SILVER BRAZING. INSULATE LINES AS SPECIFIED. REFER O M -8 AND ALSO TO DETAIL 1, THIS SHEET FOR VALVES. 7. INSTALL LEAK DETECTION CABLE IN DRIP PAN UNDER CRAG UNIT WITH SERPENTINED CABLE. CONNECT THE WATER DETECTION SYSTEM TO THE CRAC UNIT CUSTOM ALARM TERMINALS AS INDICATED BY DETAIL 2, SHEET M -9. 8. CONTRACTOR SHALL PROVIIpE A WATER TIGHT DRIP PAN BELOW NEW AND RELOCATED CRAC UNITS. DRIP PAN SHALL BE INSTALLED ON CONCRETE FLOOR BELOW FLOOR STAND. DRIP PAN SHALL BE CONSTRUCTED OF 18 GAUGE GALVANIZED STEEL WITH ALL WELDED JOINTS. T -1E DRIP PAN SHALL BE 2" DEEP AND EXTEND 2" BEYOND THE PERIMETER OF THE CRAC UNIT. TOP EDGES SHALL BE HEMMED OR ROLLED FOR SAFEY. RAISED FLOOR COIN.;,FLOOR VIBRATION ISOLATORS 3/8" THK. STEEL PLATE VIBRATION ISOLATION UNITS SHALL BE RECOMMENDED BY PUMP MANUFACTURER FOR SPECIFIED ISOLATION EXISTING CONC. HOUSEKEEPING PAD 6" TYPICAL DETAIL FOR INSULATED PIPE PLAN L + 12" 6 X 6 6/6 WELDED WIRE FABRIC NO SCALE: NO SCALE SECTION PROVIDE PEEPHOLES FOR DRAINAGE ON UNDERSIDE OF UNISTRUT WHEN MOUNTED ON EXTERIOR WALL IN HORIZONTAL PLANE TYPICAL DETAIL FOR UNINSULATED PIPE Q 2" INSULATED CHS AND 5 2" INSULATED CHR EXTENSIONS TO CRAG UNIT CHILLED WTR. COIL LEAK DETECTION MODULE CONNECT TO UNIT UMP OUT V s' 4v ob° #4 BARS @ 6" Q.C. BOTH - --- PUMP ANCHOR WAYS, TOP AND BOTTOM. BOLTS PER WELD TO STEEL PLATE AT PUMP MANUF. CORNERS. 4 THUS FINISHED FLOOR NOTES: INSULATION ABOVE SADDLES SHALL BE FOAM GLASS OF SAME THICKNESS AS PIPE INSULATION AND COMPRESSIVE STRENGTH OF NOT LESS THAN 3,300 PSI. INTEGRAL DISCONNECT R"1 P Pi f 1 -1/4" INSULATED COND. DRAIN NOTES 1. L IS THE OVERALL LENGTH OF THE EQUIPMENT. 2. W IS THE OVERALL WIDTH OF THE EQUIPMENT. 3. CONCRETE SHALL NOT BE LESS THAN 3000 PSI @ 28 DAYS. 4. HORIZONTAL SURFACES SHALL BE TAMPED AND SCREEDED TO A TRUE SURFACE (TAKING CARE TO FILL ALL LOW SPOTS) AND STEEL TROWELED TO A HARD SLATE -LIKE SURFACE. THE PAD SHALL NOT BE MARKED OFF IN AREAS OR SCORED, BUT SHALL BE LEFT IN ONE PLAIN SURFACE. 5. ALL VERTICAL SURFACES SHALL HAVE A RUBBED FINISH. 6. ALL EXPOSED EDGES SHALL BE EDGED WITH A TOOL OF SMALL CORNER RADIUS. 7. ALL REINFORCING BARS SHALL BE COVERED WITH NOT LESS THAN 1 -1/2" OF CONCRETE. 8. CONCRETE FOR PADS SHALL BE LIGHTWEIGHT CONCRETE WITH A MINIMUM OF 5.5 SACKS OF CEMENT PER CUBIC YARD. WATER TO CEMENT RATIO SHALL NOT EXCEED 6 GALLONS OF WATER PER SACK. 9. PROVIDE ANCHOR BOLTS IN PAD OF PROPER SIZE AND LOCATION FOR PUMP FURNISHED. 10. SLUMP OF CONCRETE SHALL NOT EXCEED 3 INCHES. 11. MAXIMUM AGGREGATE SIZE SHALL NOT EXCEED ONE INCH. TYPICAL CONCRETE PUMP BASE DETAIL FOAM GLASS RIGID INSULATION INSERTS AT ALL SUPPORTS OF INSULATED PIPE REFER TO NOTE 1 NEW CRAC UNIT ON FACTORY FLOOR STAND \--- FLOOR STAND TURNING VANE SUPPORT PIPES ON CONC. FLOOR W /STEEL CHANNEL. REFER TO DETAIL 6, THIS SHEET 11 CLAMP AND BOLTS GALVANIZED UNISTRUT SECTION SCALE: 1/2" =1 B -LINE SYSTEMS, INC. VIBRA CUSHION #6- 1999 ISOLATOR PROVIDE NEOPRENE PAD WHERE PIPE SUPPORT SITS ON EXTERIOR CONCRETE PAD ON GRADE OR INTERIOR CONCRETE FLOOR. TYPICAL UNISTRUT PIPING SUPPORT DETAIL 30% FILTER PROVIDE W /UNIT � - - DISPLAY MO9 FLOOfit DRIP PAN N- N , CONG . \ -- FACTORY FLOOR STAND INSTALL LEAK DETECTION CABLE IN DRIP PAN UNDER CRAG UNIT WITH SERPENTINED CABLE. REFER TO DETAIL 2, SHEET M -9 CODE COMP AppROVE D EB 1 9) 7(ADq e W u ila 5.0.1 PIKD 910* RECEIVED CITY OF TUKWILA FEB 0 5 ?Ong PERMIT CENTER WTA - 08093 COPYRIGHT CQ 2009 WTA, INC, CONSULTING ENGINEERS ABILENE, TEXAS 1Lmumr 0I U M ANS ; 4 { Expi i ='' 9- 7 r II I EQUIPMENT ROOM BUiLDOUT AT Fec. C ode: TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 - 12-'08 I e vision 1 01 -05 -09 95% REVIEW 2 01 -15 -09 100% CD 3 01 -26 -09 ADD. NO. 1 4 02 -02 -09 PERMIT SET Project No, WTA. 08093 Sheet No. M .._„ 8 HVAC DETAILS AND SECTIONS CRAC CHILLED WATER COIL CHILLED WATER VALVE CONTROL ACTUATOR, PROVIDED WITH UNIT 2 -WAY CHILLED WATER CONTROL VALVE, PROVIDED WITH UNIT CONNECT NEW 2" RUNOUT PIPING TO CRAC UNIT FOR EXISTING TAPS, REMOVE CAP AND CONNECT NEW 2" CHILLED WATER TO EXISTING 2" VALVE CHS TYPICAL CRAC UNIT - FRAME FRONT REFERENCE TEMPERATURE AND PRESSURE TEST PART BALANCING VALVE, CIRCUIT SETTER TYPE - CHR TYPICAL CHILLED WATER CONNECTION TO NEW CRAC UNIT NO SCALE NOTE: PROVIDE DIELECTRIC FITTINGS WHERE CONNECTING DISSIMILAR PIPING MATERIALS AND METALS. 1. 10' 0 "O.C. 0 6" CHWS &CHWR NOTES INDICATED BY NUMBER IN 1 % " UNITSTRUT, TYPICAL. 3. 4 "X4 "X1/4" THICK PLATE . SCALE: AS INDICATED SIDE VIEW SCALE: 1/2" =1 2. DRILL THRU PLATE % "0 AND INSTALL % "0 X 2 Y2" LONG CONCRETE BOLTS AND SLEEVES. (4 PLACES) TYPICAL. 4. FABRICATE CLAMP FROM Y8" THICK X %' WIDE METAL CLAMP /BAND. BOLT TO UNISTRUT. 5. SHEET METAL SADDLE (TYPICAL). 6. 6" CHS & CHR PLUS 2" OVERALL INSULATION. 10'-0"0.C. TYPICAL UNDERFLOOR CHILLED WATER LOOP PIPE RACK DETAIL SCALE: 1" = 1' -0" :tY`...y-- ...._�_�..':..,-._. .._ _ � • K •-- 4 '� -}- l' : LL "`:tl " ._i.i:3,. ���a..'.e �...Mt i..... ...t....(t. «._:... -. il15:1':t ' ..r •• r r- -_r'..r- ; � -. _rr•zr. --�_ . . ,...- r,:r- a- .'_r.r..- "'r. - -.... r .�: ,-.. - r:: _T__. ... ... ,, _ FRONT VIEW RAISED ACCESS FLOOR FIN. FLOOR SECTION SCALE: 1/2" =1 NOTES INDICATED BY NUMBER IN 0: I. EXISTING CHILLED WATER SUPPLY AND RETURN LOOP. 2. EXISTING 2" TAP WITH VALV AND CAP. 3. EXTEND 1 -1/4" INSULATED CONDENSATE DRAIN LINE TO NEAREST FLOOR DRAIN. 4. CONNECT RUNOUT PIPING TO UNIT. REFER TO UNIT CONNECTION DETAIL, THIS SHEET. FACTORY PIPES INSIDE UNIT, NEW 2" COPPER RUNOUT WITH SILVER BRAZING. INSULATE LINES AS SPECIFIED. REFER O M -8 AND ALSO TO DETAIL 1, THIS SHEET FOR VALVES. 7. INSTALL LEAK DETECTION CABLE IN DRIP PAN UNDER CRAG UNIT WITH SERPENTINED CABLE. CONNECT THE WATER DETECTION SYSTEM TO THE CRAC UNIT CUSTOM ALARM TERMINALS AS INDICATED BY DETAIL 2, SHEET M -9. 8. CONTRACTOR SHALL PROVIIpE A WATER TIGHT DRIP PAN BELOW NEW AND RELOCATED CRAC UNITS. DRIP PAN SHALL BE INSTALLED ON CONCRETE FLOOR BELOW FLOOR STAND. DRIP PAN SHALL BE CONSTRUCTED OF 18 GAUGE GALVANIZED STEEL WITH ALL WELDED JOINTS. T -1E DRIP PAN SHALL BE 2" DEEP AND EXTEND 2" BEYOND THE PERIMETER OF THE CRAC UNIT. TOP EDGES SHALL BE HEMMED OR ROLLED FOR SAFEY. RAISED FLOOR COIN.;,FLOOR VIBRATION ISOLATORS 3/8" THK. STEEL PLATE VIBRATION ISOLATION UNITS SHALL BE RECOMMENDED BY PUMP MANUFACTURER FOR SPECIFIED ISOLATION EXISTING CONC. HOUSEKEEPING PAD 6" TYPICAL DETAIL FOR INSULATED PIPE PLAN L + 12" 6 X 6 6/6 WELDED WIRE FABRIC NO SCALE: NO SCALE SECTION PROVIDE PEEPHOLES FOR DRAINAGE ON UNDERSIDE OF UNISTRUT WHEN MOUNTED ON EXTERIOR WALL IN HORIZONTAL PLANE TYPICAL DETAIL FOR UNINSULATED PIPE Q 2" INSULATED CHS AND 5 2" INSULATED CHR EXTENSIONS TO CRAG UNIT CHILLED WTR. COIL LEAK DETECTION MODULE CONNECT TO UNIT UMP OUT V s' 4v ob° #4 BARS @ 6" Q.C. BOTH - --- PUMP ANCHOR WAYS, TOP AND BOTTOM. BOLTS PER WELD TO STEEL PLATE AT PUMP MANUF. CORNERS. 4 THUS FINISHED FLOOR NOTES: INSULATION ABOVE SADDLES SHALL BE FOAM GLASS OF SAME THICKNESS AS PIPE INSULATION AND COMPRESSIVE STRENGTH OF NOT LESS THAN 3,300 PSI. INTEGRAL DISCONNECT R"1 P Pi f 1 -1/4" INSULATED COND. DRAIN NOTES 1. L IS THE OVERALL LENGTH OF THE EQUIPMENT. 2. W IS THE OVERALL WIDTH OF THE EQUIPMENT. 3. CONCRETE SHALL NOT BE LESS THAN 3000 PSI @ 28 DAYS. 4. HORIZONTAL SURFACES SHALL BE TAMPED AND SCREEDED TO A TRUE SURFACE (TAKING CARE TO FILL ALL LOW SPOTS) AND STEEL TROWELED TO A HARD SLATE -LIKE SURFACE. THE PAD SHALL NOT BE MARKED OFF IN AREAS OR SCORED, BUT SHALL BE LEFT IN ONE PLAIN SURFACE. 5. ALL VERTICAL SURFACES SHALL HAVE A RUBBED FINISH. 6. ALL EXPOSED EDGES SHALL BE EDGED WITH A TOOL OF SMALL CORNER RADIUS. 7. ALL REINFORCING BARS SHALL BE COVERED WITH NOT LESS THAN 1 -1/2" OF CONCRETE. 8. CONCRETE FOR PADS SHALL BE LIGHTWEIGHT CONCRETE WITH A MINIMUM OF 5.5 SACKS OF CEMENT PER CUBIC YARD. WATER TO CEMENT RATIO SHALL NOT EXCEED 6 GALLONS OF WATER PER SACK. 9. PROVIDE ANCHOR BOLTS IN PAD OF PROPER SIZE AND LOCATION FOR PUMP FURNISHED. 10. SLUMP OF CONCRETE SHALL NOT EXCEED 3 INCHES. 11. MAXIMUM AGGREGATE SIZE SHALL NOT EXCEED ONE INCH. TYPICAL CONCRETE PUMP BASE DETAIL FOAM GLASS RIGID INSULATION INSERTS AT ALL SUPPORTS OF INSULATED PIPE REFER TO NOTE 1 NEW CRAC UNIT ON FACTORY FLOOR STAND \--- FLOOR STAND TURNING VANE SUPPORT PIPES ON CONC. FLOOR W /STEEL CHANNEL. REFER TO DETAIL 6, THIS SHEET 11 CLAMP AND BOLTS GALVANIZED UNISTRUT SECTION SCALE: 1/2" =1 B -LINE SYSTEMS, INC. VIBRA CUSHION #6- 1999 ISOLATOR PROVIDE NEOPRENE PAD WHERE PIPE SUPPORT SITS ON EXTERIOR CONCRETE PAD ON GRADE OR INTERIOR CONCRETE FLOOR. TYPICAL UNISTRUT PIPING SUPPORT DETAIL 30% FILTER PROVIDE W /UNIT � - - DISPLAY MO9 FLOOfit DRIP PAN N- N , CONG . \ -- FACTORY FLOOR STAND INSTALL LEAK DETECTION CABLE IN DRIP PAN UNDER CRAG UNIT WITH SERPENTINED CABLE. REFER TO DETAIL 2, SHEET M -9 CODE COMP AppROVE D EB 1 9) 7(ADq e W u ila 5.0.1 PIKD 910* RECEIVED CITY OF TUKWILA FEB 0 5 ?Ong PERMIT CENTER WTA - 08093 COPYRIGHT CQ 2009 WTA, INC, CONSULTING ENGINEERS ABILENE, TEXAS EX. 6" EX. 6 " SEE M -6 FOR CONTINUATION cc C EX. CRAG -1 EX. CRAC -3 EX. CRAC -5 EX. 6" Ga-- C ><H EX. 6" EX. CRAC -27 I U 2 U I 0 0) 2 0 I 0 -- -{>a -- ] r>a- I EX. 2" 1j] CHR OHS POWER ROOM EXISTING EQUIPMENT ROOM RELOCATE EXISTING 6" CHILLED WATER MAINS TO ALLOW TO NEW EQUIP INSTALLATION CHS CFIR—> SCALE: NONE NEW EQUIPMENT ROOM RELOCATE EXISTING 6" CHILLED WATER ' MAINS TO ALLOW TO NEW EQUIP INSTALLATION CHS CHR EX. CRAC -11 EX. CRAC -13 NEW CRAC -18 CIRCUIT SETTER BALANCING VALVE, TYPICAL EX. CRAC-17 EX. 6" 40 /////././ /////. /../ ///7 /4://;i %/. 4½' // EX. :- L r (I) 0 x NEW CRAC -16 EX. 3" { i : J L - � - -Gq- -- I \ EX. 6" --EX. 6" U \ \ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\N\\ \\\\\\\\\\\\\\\\\\ CHILLED WATER PIPING SCHEMATIC EX. 2" "1 . EX. 6" EX. CRAC-20 EX. 2" I C>a -- -�F- 3 EX. CRAC -22 EX. CRAC -24 J EX. 2" RELOCATE PIPE TO ALLOW FOR STAIR CONSTRUCTION EX. 2" CHS /CHR VALVED AND CAPPED FOR FUTURE (TYPICAL) TEMP. /PRESS. TEST PORT., TYPICAL EX. CRAC -26 RELOCATED ELECT ROOM NOTES INDICATED BY NUMBER IN Q : 1. MAINTENANCE WINDOW WORK: FREEZE LINE AT THIS LOCATION AND INSTALL ISOLATION IN BOTH CHILLED WATER SUPPLY AND RETURN LINES. 2. MAINTENANCE WINDOW WORK: ISOLATE FLOW IN EXISTING CHILLED WATER LINES LOCATED IN NEW EQUIPMENT ROOM BY CLOSING THESE VALVES (NEW VALVES AT SOUTHWEST OF NEW EQUIPMENT ROOM AND EXISTING VALVES AT NORTH OF NEW EQUIPMENT ROOMS). 3. EXISTING CRAC #26 AND ACCESSORIES TO BE RELOCATED TO ALLOW FOR NEW WALL CONSTRUCTION. 4. CONNECT NEW 6" LINES TO EXISTING. 5. RECONNECT EXISTING CRAC #26 TO NEW 6" CHILLED WATER LOOP. PROVIDE NEW 2" TAPS. REFER TO TYPICAL CRAG UNIT CONNECTION DETAIL, SHEET M -8. CONNECT NEW CRAC UNITS TO EXISTING CHILLED WATER LOOP UTILIZING EXISTING 2" TAPS. EXTEND NEW 2" RUNOUTS FROM EXISTING VALVES AND CONNECT TO UNIT REFER TO TYPICAL CRAC UNIT CONNECTION DETAIL, SHEET M -8. 7. EXTEND 2" RUNOUTS FROM NEW PORTION OF CHILLED WATER LOOP TO NEW CRAC #18. REFER TO TYPICAL CRAG UNIT CONNECTION DETAIL, SHEET M -8. . t ., 8. CONNECT NEW 3" CHILLED WATER LINES TO EXISTING 3" CHILLED WATER LOOP AT THIS POINT. PROVIDE CAP IN EXISTING LOOP JUST BEYOND NEW 3" TAPS. EXTEND 3" BRANCH LINES AS INDICATED. 9. CONNECT NEW 3" LINES TO EXISTING. 10. COORDINATE WITH ELECTRICAL CONTRACTOR TO INSTALL GROUNDING FOR CHILLED WATER PIPING WHERE PIPING PENETRATES NEW EQUIPMENT ROOM WALL. tiOci% 0(3 wt) rum CODE COMPLIANCE CE APPPOVED FEB 1 q 7111Iq City offav ING DIVISION RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEER ABILENE, TEXAS _ _ ...IA I® <M „'i,1Ct MO, CJ � W % sit } N a ! ;i, I 1. J V' l'b x / (( : ��iies 9 71) I Fac. Code :TYKWWA Wn D IM, PS, ZJ Drawn y Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -O8 Revi ion 1 01 -05 -09 . 95% REVIEW 2 01 -15 -09 100% CD 3 01 -26 -09 ADD. NO. 1 4 02 -02 -09 PERMIT SET Project No. WTA. 08093 Sheet No. M CHILLED WATER PIPING SCHEMATIC EX. 6" EX. 6 " SEE M -6 FOR CONTINUATION cc C EX. CRAG -1 EX. CRAC -3 EX. CRAC -5 EX. 6" Ga-- C ><H EX. 6" EX. CRAC -27 I U 2 U I 0 0) 2 0 I 0 -- -{>a -- ] r>a- I EX. 2" 1j] CHR OHS POWER ROOM EXISTING EQUIPMENT ROOM RELOCATE EXISTING 6" CHILLED WATER MAINS TO ALLOW TO NEW EQUIP INSTALLATION CHS CFIR—> SCALE: NONE NEW EQUIPMENT ROOM RELOCATE EXISTING 6" CHILLED WATER ' MAINS TO ALLOW TO NEW EQUIP INSTALLATION CHS CHR EX. CRAC -11 EX. CRAC -13 NEW CRAC -18 CIRCUIT SETTER BALANCING VALVE, TYPICAL EX. CRAC-17 EX. 6" 40 /////././ /////. /../ ///7 /4://;i %/. 4½' // EX. :- L r (I) 0 x NEW CRAC -16 EX. 3" { i : J L - � - -Gq- -- I \ EX. 6" --EX. 6" U \ \ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\N\\ \\\\\\\\\\\\\\\\\\ CHILLED WATER PIPING SCHEMATIC EX. 2" "1 . EX. 6" EX. CRAC-20 EX. 2" I C>a -- -�F- 3 EX. CRAC -22 EX. CRAC -24 J EX. 2" RELOCATE PIPE TO ALLOW FOR STAIR CONSTRUCTION EX. 2" CHS /CHR VALVED AND CAPPED FOR FUTURE (TYPICAL) TEMP. /PRESS. TEST PORT., TYPICAL EX. CRAC -26 RELOCATED ELECT ROOM NOTES INDICATED BY NUMBER IN Q : 1. MAINTENANCE WINDOW WORK: FREEZE LINE AT THIS LOCATION AND INSTALL ISOLATION IN BOTH CHILLED WATER SUPPLY AND RETURN LINES. 2. MAINTENANCE WINDOW WORK: ISOLATE FLOW IN EXISTING CHILLED WATER LINES LOCATED IN NEW EQUIPMENT ROOM BY CLOSING THESE VALVES (NEW VALVES AT SOUTHWEST OF NEW EQUIPMENT ROOM AND EXISTING VALVES AT NORTH OF NEW EQUIPMENT ROOMS). 3. EXISTING CRAC #26 AND ACCESSORIES TO BE RELOCATED TO ALLOW FOR NEW WALL CONSTRUCTION. 4. CONNECT NEW 6" LINES TO EXISTING. 5. RECONNECT EXISTING CRAC #26 TO NEW 6" CHILLED WATER LOOP. PROVIDE NEW 2" TAPS. REFER TO TYPICAL CRAG UNIT CONNECTION DETAIL, SHEET M -8. CONNECT NEW CRAC UNITS TO EXISTING CHILLED WATER LOOP UTILIZING EXISTING 2" TAPS. EXTEND NEW 2" RUNOUTS FROM EXISTING VALVES AND CONNECT TO UNIT REFER TO TYPICAL CRAC UNIT CONNECTION DETAIL, SHEET M -8. 7. EXTEND 2" RUNOUTS FROM NEW PORTION OF CHILLED WATER LOOP TO NEW CRAC #18. REFER TO TYPICAL CRAG UNIT CONNECTION DETAIL, SHEET M -8. . t ., 8. CONNECT NEW 3" CHILLED WATER LINES TO EXISTING 3" CHILLED WATER LOOP AT THIS POINT. PROVIDE CAP IN EXISTING LOOP JUST BEYOND NEW 3" TAPS. EXTEND 3" BRANCH LINES AS INDICATED. 9. CONNECT NEW 3" LINES TO EXISTING. 10. COORDINATE WITH ELECTRICAL CONTRACTOR TO INSTALL GROUNDING FOR CHILLED WATER PIPING WHERE PIPING PENETRATES NEW EQUIPMENT ROOM WALL. tiOci% 0(3 wt) rum CODE COMPLIANCE CE APPPOVED FEB 1 q 7111Iq City offav ING DIVISION RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEER ABILENE, TEXAS Fac. Code :TYKWWA Drawn By IM, PS, ZJ Designed By: KCM, DL ZJ Pro'. Mgr.: KCM g IUI Revision 01 -05 -09 01 -15 -09 9 §% REVIEW 100% CD 3 01-26-09 4 02 -02 -09 Project No. WTA. 08093 CHILLED WATER PIPING SCHEMATIC NEW CHILLER # 2 175 TONS 365 GPM EX. CHILLER # 2 175 TONS 365 GPM (TYP.) (TYP.) (TYP.) EX. CHILLER # 1 175 TONS 365 GPM 0 EX. 6" CI-IS 10 6" CHS - 6" CHR 1Q EX. 6" CHR 0 EX. 6" CHS EX. 8" CHR HEADER IN CHILLER YARD EX. 6" CHR 0 0 EX. B" NEW AUTOMATIC FLOW CONTROL VALVE EX. 8" CHS HEADER IN CHILLER YARD EX. MOTORIZED CONTROL VALVE (TYPICAL) EX. AUTOMATIC FLOW CONTROL VALVE (TYPICAL) EQUIPMENT COURTYARD PUMP ROOM 6" CHS - 6" CHR SUCTION DIFFUSER (TYPICAL) 6" EX. CHILLED WATER PUMP 1 365 GPM 6" - EX. CHILLED WATER PUMP 2 365 GPM 6" - NEW. CHILLED WATER PUMP 3-08 365 GPM EX. WALL MOUNTED COUPON RACK SAMPLING GENERAL NOTES: EX. PRESSURE CONTROL VALVE -_ 1. EXISTING CHILLED WATER SYSTEM CONTAINS 30% POLY PROPYLENE GLYCOL. THIS SYSTEM SHALL BE CONVERTED TO WATER ONLY FREEZE PROTECTION HEAT TAPE SHALL BE DEPLOYED AS INDICATED ON KEYED NOTE 10 IN ORDER TO PROTECT CHILLED WATER LINES OUTSIDE, CONTRACTOR SHALL FLUSH EXISTING SYSTEM TO REMOVEGLYCOL OUT OF SYSTEM. THIS IS DONE IN ORDER TO INCREASE COOLING CAPACITY AT EACH CRAC UNIT. 2. SYSTEM IS N + 1. CONTROLLED BY THE CSI/TAC BUILDING AUTOMATION SYSTEM. NEW CHILLER AND PUMP SHALL BE CONNECTED TO THIS SYSTEM. BUILDING AUTOMATION SYSTEM WORK SHALL BE OUTSIDE THIS CONTRACT. 1" EX. FLOW LJ METER EX. 4" CHW BYPASS NC EX. 4 "CHW BYPASS EX. 3/4 EX. 3/4" EX. 6" CHR EX. C - IEMICAL POT FEEDER EX. 'I 1/2" CHILLED WATER PIPING SCHEMATIC EX. AUTOMATIC AIR VENT EX. EXPANSION EX. AIR TANK SEPERATOR NOTES INDICATED BY NUMBER IN 1. NEW PUMP PAD ON EXISTING CONCRETE HOUSE KEEPING PAD, REFER TO DETAIL 5, SHEET M -8. 2. ECCENTRIC REDUCER AT PUMP INLET. 3. SUCTION DIFFUSER. 4. FLEXIBLE PIPE CONNECTOR. 5. CONCENTRIC REDUCER AT VERTICAL PUMP OUTLET. 6. PRESSURE GAUGE WITH GAUGE COCK. 7. TRIPLE DUTY VALVE. 8. THERMOMETER. 9. PRESSURE/TEMPERATURE TEST PORT (PETE'S PLUG). 10. PROVIDE FREEZE PROTECTION TAPE FOR ALL PIPING OUTSIDE OF BUILDING. REFER TO SPECIFICATIONS. 11. "Y" TYPE STRAINER. PROVIDE WITH FULL SIZE BLOW DOWN VALVE (BALL TYPE) AND CAP. EX. TEMP SENSOR EX. 1 1/2" N.O. N.O. EX. FLOW METER FIN. FLOOR _ EX. 55 4 GALLON AUTOMATIC GLYCOL FEED 10 -45 PSI EX. PRESSURE SWITCH 18 PSI TS EX. TEMP SENSOR N.C. EX. 11/2" - EX. GLYCOL FEED PUMP 3!4'` PSI PRV EX. CONTROLLER f1 12. CONNECT 6" LINE TO EXISTING ISOLATION VALVE AND EXTEND TO SUCTION SIDE OF NEW PUMP AS INDICATED. 13. EXTEND 6" PUMP DISHCHARGE LINE FROM NEW PUMP UP AND CONNECT TO EXISTING ISOLATION VALVE. 14. CONNECT 6" LINE TO EXISTING CHILLED WATER RETURN BRANCH LINE ISOLATION VALVE AND EXTEND TO NEW CHILLER AS INDICATED. 15. EXTEND 6" LINE FROM NEW CHILLER SUPPLY CONNECTION TO EXISTING CHILLED WATER SUPPLY BRANCH LINE ISOLATION VALVE AND CONNECT. 6" EX. 1 1/2" VACUUM BREAKER Maclly Ldp (VIM at* COMPLIANCE APPRQVIED FEB 1 9 211114 City Of Tukwila _,BUILDING DIVISION 1 1/2 „ -- TO BLDG. CONNECTION EX. 6" CHILLED WATER RETURN EX. 6" CHILLED WATER SUPPLY. REFER TO SHEET M -7 FOR CONTINUATION RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT 02009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS (113) (112) (111) (110) MDS-SIDE B (109) MAIN BREAKER MDSB (108) TIE BREAKER (107) MAIN BREAKER MDSA -(106) MDS-SIDE A (105) (104) (103) (102) (101) BATTERY 'ID . BATTERY 1C ...._ .._. __ BATTERY 1B . _ I pet _ _n [LumrF1 F ,,,, ,,, . -..... q ti . 1,. , t•-• ,,', *1 (-P , %. if ' 1 . 14 1 (I 41, , t 1 /''S ‘ . / i A " 't. ^ \ 40, '. .)._, i- ' .■:5;,. C IS' .---.--- --.. ' ' • 0, - 111.1111.1, F xpires .4. /0 Is\‘0110.` EQUIPMENT ROOM B U /L D O U T AT Designed By KCM, DL, ZJ Proj. Mgr.: KCM Date: 12-12-08 Revision 1 01-05-09 95% REVIEW 2 01-15-09 100°/0 CD 3 01-26-09 ADD. NO. 1 4 02-02-09 PERMIT SET Project No. WTA. 08093 Sheet No. M.5 PARTIAL FIRST FLOOR PLAN - CHILLER YARD AND MECHANICAL BATTERY 'ID . BATTERY 1C ...._ .._. __ BATTERY 1B . _ BATTERY lA . _. _. . ., U PS-1 ... . .. EXISTING CHILLED WATER PUMP NEW P3 DISC: EXISTING P1 EXISTING P2 DISC. EXISTING CHILLED WATER PUMP P2 NEW CHILLED WATER PUMP P3-08' --EXISTING 6'x4' ACCUSTICAL LOUVER • • • `. EX. 6" CHS EXISTING CONTROL INTERFACE EXISTING AIR COOLED CHILLER 1 ( 6" CHR 8, CHS PIPING OVERHEAD EXISTING AIR COOLED CHILLER 2 EXISTING MOTORIZED CONTROL VALVE ---- O EXISTING 8" CHR HEADER - BOTTOM EXISTING 8" CHS HEADER - TOP O 0 0 0 O 0 O 0 CHILLER YARD I (EXISTING 6" CHR EX. 4" PCV EX. 4" FLOW METER EX. 4" BYPASS EXISTING JANITOR SINK EXISTING GLYCOL FEED UNIT GF-1 EXISTING CHEMICAL POT FEEDER EXISTING EXPANSION TANK SCALE: 1/4" EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND/OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGINEER. EXISTING 65(4' ACCUSTICAL LOUVER 7 a GENERAL NOTES: M I I i=t I I i 7 A I ■I EXISTING 6" CHS ® NEW 6" CHR C.B. NEW AIR COOLED CHILLER 3-08 ON EXIST. CONC. PAD KII NEW MOTORIZED CONTROL VALVE CONNECT NEW 6" CHR TO EXISTING EXISTING 6" CHR PARTIAL FIRST FLOOR PLAN - CHILLER YARD AND PUMP ROOM, MECHANICAL 1. EXISTING CHILLED WATER SYSTEM CONTAINS 30% POLY PROPYLENE GLYCOL. THIS SYSTEM SHALL. BE CONVERTED TO WATER ONLY. FREEZE PROTECTION HEAT TAPE SHALL BE DEPLOYED AS INDICATED ON KEYED NOTE 10 IN ORDER TO PROTECT CHILLED WATER LINES OUTSIDE. CONTRACTOR SOLI FLUSH EXISTING SYSTEM TO REMOVE GLYCOL OUT OF SYSTEM. THIS IS DONE IN ORDER TO INCREASE COOLING CAPACITY AT EACH CRAG UNIT. 2. CONTRACTOR SHALL PROVIDE DIELECTRIC FITTINGS OR FLANGES AS SPECIFIED WHERE CONNECTING DISSIMILAR PIPING. -NEW CHS EXISTING 6" CHS OFFSET CHILLED WATER RETURN LINE OVER CHILLED WATER SUPPLY LINE AS REQUIRED TYPICAL CONNECT NEW 6" CHS TO EXISTING SCALE: 1/4" = NOTES INDICATED BY NUMBER IN 0: 1. PROVIDE PIPE SUPPORT AS INDICATED. REFER TO DETAIL 1, SHEET M-9. PANEL "ULPP1-1" 2. PROVIDE FREEZE PROTECTION TAPE, INSULATION AND ALUMINUM JACKET FOR NEW PIPING. REFER TO SPECIFICATIONS. 3. REMOVE ALUMINUM JACKET AND INSULATION FROM EXISTING EXTERIOR PIPING AND PROVIDE FREEZE PROTECTION TAPE AND NEW INSULATION. REFER TO SPECIFICATIONS. 4. CONNECT CHILLED WATER PIPING TO NEW PACKAGED AIR COOLED CHILLER, REFER TO "CHILLED WATER PIPING SCHEMATIC", SHEET M-6. 5. EXISTING GLYCOL FEED SYSTEM TO BE ABANDONED IN PLACE. ENSURE ISOLATION VALVES ARE CLOSED. SYSTEM SHALL BE CONVERTED TO WATER. REFER TO CHILLED WATER PIPING SCHEMATIC. 6. PUMP PAD, REFER TO DETAIL 5, SHEET M-8. 7. CONNECT NEW 6" CHILLED WATER SUCTION LINE TO EXISTING TAP AT SUCTION HEADER. REFER TO "CHILLED WATER PIPING SCHEMATIC", SHEET M-6 FOR VALVE CONFIGURATIONAND REQUIREMENTS. EXTEND 6" CHILLED WATER LINE FROM NEW PUMP DISCHARGE UP AND CONNECT TO TAP AT DISCHARGE HEADER. REFER TO "CHILLED WATER PIPING SCHEMATIC", SHEET M-6 FOR VALVE CONFIGURATION AND REQUIREMENTS. x LITHONIA LIGHTING :1< CONTROLLER PANEL "LPPAl" PARTIAL. FIRST FLOOR PLAN 11D1-- 013 L > 1 < - itakalagiEW MOM VAigEla440 4 ,, 141ilat 410111Wit l&WEBAM U7kal.fai9S AQUI:AUL ' 1.1ri ELECTRICAL ROOM RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER AUTOSTICK II POVVER TRACK 9000 POWER MONITORING INTERFACE (G) --PANEL "URDP1-3" 9. PROVIDE MINIMUM 5 TON PORTABLE SPOT COOLER IN BUILDING ELECTRICAL ROOM WITH HOT AIR DISCHARGE DUCT EXTENDED TO EXTERIOR OF BUILDING. SPOT COOLER SHALL BE UTILIZED DURING CONSTRUCTION PERIODS WHERE CHILLED WATER SERVICE TO CRAC'S #29 AND #30 IS DISRUPTED. CONTRACTOR SHALL MONITOR CLOSELY AND MAINTAIN CONDESATE DRAIN TANK. ENSURE NO OBSTRUCTION ARE WITHIN 24" CLEAR OF UNIT ON ALL SIDES (OR AS RECOMMENDED BY UNIT MANUFACTURERS. 10. FREEZE PROTECTION TAPE CIRCUIT FABRICATION KIT J-BOX. PROVIDE (1) CIRCUIT FOR CHILLED WATER SUPPLY PIPING AND (1) CIRCUIT FOR CHILLED WATER RETURN PIPING. PROVIDE IN LINE T-SPLICE KITS AS REQUIRED TO ALLOW FOR BRANCH PIPING PROTECTION. FREEZE PROTECTION TAPE SHALL BE THERMON 5-FLX-1 (30A BREAKER) SELF REGULATING HEATING CABLE OR APPROVED EQUAL. 11. CONTROL VALVE SHALL BE CONNECTED TO EXISTING CSI/TAC CHILLED WATER CONTROL SYSTEM TO OPEN WHEN CHILLER AND PUMP ARE OPERATING AND CLOSE WHEN CHILLER AND PUMP STOP. (.1) uu rum DE COMPLIANCE APPROVED FEB 1. PI 2 1111 4 City0fTukwila ILD1NGDIVO ISIN 4 . •■• ' WTA - 08093 COPYRIGHT © 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS FUTURE PANEL "DP4 1. MATCHLINE CHS CHR VA AA„. DCGB-2 AGB- E;(R;: Nfiff,.1\11 RC Orvi GENERAL NOTES: ■lai IMMO ( EX. CSITTAC BAS PANELS BRGB-1 ) S E f3:1 7 oi-ocut-oFio otisoivoio yon-sio NUM- 1 SO 01 150,02 150..0.?, 150,04 , s ' NO-IMANMEOW 152. to-o-or-o- I 50,06 ANALM'ER ZONE 3 BOX1 DESIGNATE 60% PERFORATED AIR TILE. REFER TO ARCHITECTURAL SPECIFICATION. , • , 1 $1 .()‘' 1LU i O .10 1 !.',1 INNINMFON 111-INME IONINAII 1111-11I-MIN INFONMI-NEIN Ni•MON-111 MENNE REFER TO TO M-3 FOR CONTINUATION iiFY11 Olt ININNIANNI 150.07 15C., . I) 130G B-1 4■;) '1.19 .(1 '1=1 I,; "11'1} 1V.,1 0'",) IN IN- IIIHN 111-10. IN IN OW INMION IIHNHOI 150 .09 50.10 FUTURE NEW PANELBOARD PANEL "DP3A"-- '149. '10 1 11 4 149 1i 9.14 NI NI IN 1111 • MAI ON II 111-IWINAIN INNFOOF IN IN 111 Ai SHINANINI- MOAN- 1INFONION IjI-I N110 5t.). 1150. 2. CONTRACTOR SHALL PROVIDE QUANTITY OF PERFORATED RAISED FLOOR TILES AS INDICATED ON DRAWINGS CONTRACTOR SHALL INSTALL PERFORATED FLOOR TILES AS DIRECTED BY VERIZON BUSINESS REPRESENTATIVE AND SHALL PROTECT AND STORE REMAINING PERFORATED FLOOR TILES ON SITE AS DIRECTED BY VZB FOR FUTURE INSTALLATION. 3. AFTER ALL WORK IS COMPLETE, CONTRACTOR SHALL REMOVE ALL CONSTRUCTION TRASH AND DEBRIS AND VACUUM CONCRETE SURFACE BELOW RAISED FLOOR TO INSURE ENTIRE AREA BELOW RAISED FLOOR IS LEFT CLEAN AND DUST FREE. 4. CONTRACTOR SHALL PROVIDE DIELECTRIC FITTINGS OR FLANGES AS SPECIFIED WHERE CONNECTING DISSIMILAR PIPING MATERIALS AND METALS. EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND/OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGINEER. POWER ROOM -r- 1111-IWNFIGHN Ad IN MINN/ 4 . 164..1 ti.=, IW 1 SO ..1 3 '1 14 150.15 Ji 11.) tIi i •52. 14 152,15 152.1 BLOW Milk '15.1,17 151 "1 '16 15'1.1 NWINIIIHININ INNS IN NI NO-MINFONEN •i34 it) 16 NUM Nil* NUNIFIWIN tiit MID to-o-so- 50..16 "17217 SCALE: 1/4" PANE-. "CRPPA1" EX: VCRS - XISTIN CHS/C R r I t I 1 I 1 1 1 I 1 / 1 / 1 I t I / 1 /1•1 EINEM 111.1 Miff. LINES CONTINUE ON SHEET M-3 (.1) r- 0 0 1 oi) 1 / 1 / 1 I / 1 () / PANEL PANEL "BPPA2" "BPPB2" p "C 1N EL PPB1" EXISTING 6" CHS/CH it 111111111114_ 0 II /1= oI M IN IN tilIMIN 101 I 7 P . ; 01 1 5. ()2 ; NI IN IN MINIM IN • INNWINHIIIMOM-M I ti •17.3.02 NOTES INDICATED BY NUMBER IN 1. CHILLED WATER PIPING BELOW RAISED ACCESS FLOOR, VERTICALLY STACKED WITH 6" CHILLED WATER SUP1 ON TOP, 6" CHILLED WATER RETURN AT BOTTOM. 2. MAINTENANCE WINDOW VVORK: ISOLATE FLOW IN THIS PIPE SECTION BY CLOSING THESE VALVES HERE AND AT THE NEW SOUTH ISOLATION VALVES (REFER TO SHEET M-3) TO ALLOW FOR THE RELOCATION OF THE 6" CHILLED WATER SUPPLY AND RETURN LINES AS INDICATED ON SHEET M-3 AND OTHER WORK RELATED TO EXISTING LOOP. 76, 04 . ra-ad thaL .ua Aar NIONVINIW FUTUR PDU FUTUR PDU 3. CONNECT NEW 6" LINES TO EXISTING. 4. RECONNECT EXISTING CRAC 11 TO EXISTING 6" CHILLED WATER LOOP. PROVIDE NEW 2" TAPS. REFER TO TYP CAL CRAG UNIT CONNECTION DETAIL, SHEET M-8. 5. MAINTENANCE WINDOW WORK: DUE TO THE STAIRS CONSTRUCTION, CONTRACTOR SHALL ISOLATE FLOW DOWNSTREAM OF THESE VALVES TO ALLOW RE-ROUTING OF THE CHILLED WATER SUPPLY AND RETURN LINES AS INDICATED. THESE LINES SERVE CRAC UNITS #29 AND #30 IN ELEC. Room, THEREFORE TEMPORARY A/C UNIT SHALL BE PROVIDED IN THAT ROOM. REFER TO M-. 6. REMOVE THIS PORTI9N OF CHILLED WATER SUPPLY AND RETURN PIPING TO ALLOW FOR STAIR CONSTRUCTI N. ON IN I. EX. 3" CHS AND 3" CHR RISER UP WALL TO CRAC UNITS #29 AND 30 IN ELEC ROOM 17'5- MI NIM A111..? I PAID 1 173.04 172.04 11-0-1114tHIS PARTIAL FIRST FLOOR PLAN - HVAC NORTH 777 .1 ;T7(1 1 "7. 7 77177737 717 7 t787 "1 174,05 17 174.0?' INAINVIVIN III Mt IMIII-ONFANIANHINAINIWIIHWIWIN 17 12.05 MAN PANEL "ULPP1-1% ANALASER ZONE 4 BOX 1 76.06 1 76 .07 I o IN MAN ik1111..) MID 17 '1 4 715, 0:) uu MID l'Olf) Nt NEM MAN -111-1111-OHNIMINI II NI IN IN 111-111-NNIIN OCNNINSIt MAN NI MIWILIANAIWIWININWIII . 173 05 '173.00 '171.07 173.08 '172 09 173.10 '173.1 'I • j 72.06 1'72.0'7 172,06 172,09 111411-1111-M-OHNIMI MillIMMI MINFINFININ NI-IN-INHW MIN 1111 INNWINFIWNI 101-811- ' 0,7, 171 ."0 =Emil MEM PDF 2U- INOWIWININ NAM IN .'74.I9 •76,11 -r BATTERY 1D 11'1 1 (St INNHIWNWIN '177 •1 , i/h 111411111111 1\11!1..■ o. 1 1V111;) __..... IWINNIMINI M- -- U IWOWSZNII marro 'I 7'7.12 177,13 177 14 '117 15 I 177.10 1 /8,12 INHININ SWIN-IN Na- 1 40 1D F® 777 4.. '1 0 174.11 '1 17.4. 'I SSW M111-INIONINIWNI “1 I BATTERY 1C 12 I . 171E'; .14 '1 SN1N - 101 - 611 .- 404 1151 IVO IN- IN- OWNII-NW ELEC. ROOM M I t) IWOWNI '175.14 BATTERY 1B tvl (01-0.10-10- 175 .15 MIN IN NI NO INFIWINIifk MEMO* IN IN INAN '1 112 .12 173.'1'3 4 414 17'5 72. 10 172,1 '1 '172.12 172.'1 5 172.14 1 7:2,15 OWINHIENWIN 11141 NINNOWNWININOWNWN11111161 • OM MINFINHIN 7. PROVIDE PIPE SUPPORT FOR CHS AND CHR PIPING INSTALLED BELOW RAISED ACCESS FLOOR. REFER TO DETAIL 6, SHEET M-8 FOR PIPING SUPPORT DETAIL. 8. REMOVE CHILLED WATER SUPPLY AND RETURN BRANCH LINES BACK TO LOOP AND CAP TO ALLOW FOR WALL CONSTRUCTION. 9. COORDINATE WITH ELECTRICAL CONTRACTOR TO INSTALL GROUNDS FOR PIPE WALL PENETRATION AT THIS LOCATION. REFER TO ELECTRICAL DRAVVINGS. 10. CONTRACTOR TO INSTALL A WATER TIGHT DRIP ENCLOSURE BELOW EXISTING CRAC UNITS. ENCLOSURE TO BE CONSTRUCTED OF 18 GAUGE GALVANIZED STEEL ANGLES WITH ALL WELDED JOINTS. ENCLOSURE SHALL BE 2" DEEP AND EXTEND 2" BEYOND THE PERIMETER OF THE CRAC. TOP EDGES SHALL BE HEMMED OR ROLLED FOR SAFETY. EPDXY PAINT ENTIRE AREA WITHIN THE ENCLOSURE WITH SHERVVIN WILLIAMS ARMOSEAL 1000HS-SW 1006 OR APPROVED EQUAL. REFER TO DETAIL 3, SHEET M-9. CONTRACTOR SHALL INSTALL WATER LEAK DETECTION CABLE SERPENTINED IN DRIP PAN BELOW UNIT. CONNECT THE WATER LEAK DETECTION SYSTEM TO THE CRAG CUSTOM ALARM TERMINAL AS INDICATED BY DETAIL 2, SHEET M-9. 46.16 176,16 IIIMASINN• !vl 17.4.14 1 '1 4,10 -10411-MAIM WM= MIN NIHISHWIWIII St MIN NI IWO- IN NFO.1 , 5) REFER TO M-3 FOR CONTINUATION (/ 3) BATTERY 1A M ID MiD asalarat-ai aa salaam awaalia 172, 12 I i75:17• I 175.16 1911111 ..?3.16 AN MAIM au i42.12 172.17 iIs,iii -151411-10- wwww1 •Fmpl. MIME UPS-1 MO 1 3 RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 8 0 tot% in.m) I l OP 15 4 0 NAIr , ONE VILLAGE DRIVE, SUITE 51 .A.15ILEN , i`EXEAS '796® 13257 695 -1090 FAX 13253 695 •37 ...1. - , .p. ?,‘(_, i 0 0 , V AS . ,... 0 = , 0 s, lif e 6 t , c (,4z Z1-9 [Expires c , , ,, v 40 I EQUIPMENT ROOM BUILDOV d AT Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Prof. Mgr.: KCM ....-- Date: 12-12-08 _a.. Revision 01-05-09 95% REVIEW 2 01-15-09 100% CD 3 01-26-09 ADD. NO. 1 4 02-02-09 PERMIT SET ........ Project No. WTA. 08093 Sheet No. M.4 PARTIAL FIRST FLOOR PLAN - HVAC - NORTH FUTURE PANEL "DP4 1. MATCHLINE CHS CHR VA AA„. DCGB-2 AGB- E;(R;: Nfiff,.1\11 RC Orvi GENERAL NOTES: ■lai IMMO ( EX. CSITTAC BAS PANELS BRGB-1 ) S E f3:1 7 oi-ocut-oFio otisoivoio yon-sio NUM- 1 SO 01 150,02 150..0.?, 150,04 , s ' NO-IMANMEOW 152. to-o-or-o- I 50,06 ANALM'ER ZONE 3 BOX1 DESIGNATE 60% PERFORATED AIR TILE. REFER TO ARCHITECTURAL SPECIFICATION. , • , 1 $1 .()‘' 1LU i O .10 1 !.',1 INNINMFON 111-INME IONINAII 1111-11I-MIN INFONMI-NEIN Ni•MON-111 MENNE REFER TO TO M-3 FOR CONTINUATION iiFY11 Olt ININNIANNI 150.07 15C., . I) 130G B-1 4■;) '1.19 .(1 '1=1 I,; "11'1} 1V.,1 0'",) IN IN- IIIHN 111-10. IN IN OW INMION IIHNHOI 150 .09 50.10 FUTURE NEW PANELBOARD PANEL "DP3A"-- '149. '10 1 11 4 149 1i 9.14 NI NI IN 1111 • MAI ON II 111-IWINAIN INNFOOF IN IN 111 Ai SHINANINI- MOAN- 1INFONION IjI-I N110 5t.). 1150. 2. CONTRACTOR SHALL PROVIDE QUANTITY OF PERFORATED RAISED FLOOR TILES AS INDICATED ON DRAWINGS CONTRACTOR SHALL INSTALL PERFORATED FLOOR TILES AS DIRECTED BY VERIZON BUSINESS REPRESENTATIVE AND SHALL PROTECT AND STORE REMAINING PERFORATED FLOOR TILES ON SITE AS DIRECTED BY VZB FOR FUTURE INSTALLATION. 3. AFTER ALL WORK IS COMPLETE, CONTRACTOR SHALL REMOVE ALL CONSTRUCTION TRASH AND DEBRIS AND VACUUM CONCRETE SURFACE BELOW RAISED FLOOR TO INSURE ENTIRE AREA BELOW RAISED FLOOR IS LEFT CLEAN AND DUST FREE. 4. CONTRACTOR SHALL PROVIDE DIELECTRIC FITTINGS OR FLANGES AS SPECIFIED WHERE CONNECTING DISSIMILAR PIPING MATERIALS AND METALS. EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND/OR SITE VISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN. VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID. AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT/ENGINEER. POWER ROOM -r- 1111-IWNFIGHN Ad IN MINN/ 4 . 164..1 ti.=, IW 1 SO ..1 3 '1 14 150.15 Ji 11.) tIi i •52. 14 152,15 152.1 BLOW Milk '15.1,17 151 "1 '16 15'1.1 NWINIIIHININ INNS IN NI NO-MINFONEN •i34 it) 16 NUM Nil* NUNIFIWIN tiit MID to-o-so- 50..16 "17217 SCALE: 1/4" PANE-. "CRPPA1" EX: VCRS - XISTIN CHS/C R r I t I 1 I 1 1 1 I 1 / 1 / 1 I t I / 1 /1•1 EINEM 111.1 Miff. LINES CONTINUE ON SHEET M-3 (.1) r- 0 0 1 oi) 1 / 1 / 1 I / 1 () / PANEL PANEL "BPPA2" "BPPB2" p "C 1N EL PPB1" EXISTING 6" CHS/CH it 111111111114_ 0 II /1= oI M IN IN tilIMIN 101 I 7 P . ; 01 1 5. ()2 ; NI IN IN MINIM IN • INNWINHIIIMOM-M I ti •17.3.02 NOTES INDICATED BY NUMBER IN 1. CHILLED WATER PIPING BELOW RAISED ACCESS FLOOR, VERTICALLY STACKED WITH 6" CHILLED WATER SUP1 ON TOP, 6" CHILLED WATER RETURN AT BOTTOM. 2. MAINTENANCE WINDOW VVORK: ISOLATE FLOW IN THIS PIPE SECTION BY CLOSING THESE VALVES HERE AND AT THE NEW SOUTH ISOLATION VALVES (REFER TO SHEET M-3) TO ALLOW FOR THE RELOCATION OF THE 6" CHILLED WATER SUPPLY AND RETURN LINES AS INDICATED ON SHEET M-3 AND OTHER WORK RELATED TO EXISTING LOOP. 76, 04 . ra-ad thaL .ua Aar NIONVINIW FUTUR PDU FUTUR PDU 3. CONNECT NEW 6" LINES TO EXISTING. 4. RECONNECT EXISTING CRAC 11 TO EXISTING 6" CHILLED WATER LOOP. PROVIDE NEW 2" TAPS. REFER TO TYP CAL CRAG UNIT CONNECTION DETAIL, SHEET M-8. 5. MAINTENANCE WINDOW WORK: DUE TO THE STAIRS CONSTRUCTION, CONTRACTOR SHALL ISOLATE FLOW DOWNSTREAM OF THESE VALVES TO ALLOW RE-ROUTING OF THE CHILLED WATER SUPPLY AND RETURN LINES AS INDICATED. THESE LINES SERVE CRAC UNITS #29 AND #30 IN ELEC. Room, THEREFORE TEMPORARY A/C UNIT SHALL BE PROVIDED IN THAT ROOM. REFER TO M-. 6. REMOVE THIS PORTI9N OF CHILLED WATER SUPPLY AND RETURN PIPING TO ALLOW FOR STAIR CONSTRUCTI N. ON IN I. EX. 3" CHS AND 3" CHR RISER UP WALL TO CRAC UNITS #29 AND 30 IN ELEC ROOM 17'5- MI NIM A111..? I PAID 1 173.04 172.04 11-0-1114tHIS PARTIAL FIRST FLOOR PLAN - HVAC NORTH 777 .1 ;T7(1 1 "7. 7 77177737 717 7 t787 "1 174,05 17 174.0?' INAINVIVIN III Mt IMIII-ONFANIANHINAINIWIIHWIWIN 17 12.05 MAN PANEL "ULPP1-1% ANALASER ZONE 4 BOX 1 76.06 1 76 .07 I o IN MAN ik1111..) MID 17 '1 4 715, 0:) uu MID l'Olf) Nt NEM MAN -111-1111-OHNIMINI II NI IN IN 111-111-NNIIN OCNNINSIt MAN NI MIWILIANAIWIWININWIII . 173 05 '173.00 '171.07 173.08 '172 09 173.10 '173.1 'I • j 72.06 1'72.0'7 172,06 172,09 111411-1111-M-OHNIMI MillIMMI MINFINFININ NI-IN-INHW MIN 1111 INNWINFIWNI 101-811- ' 0,7, 171 ."0 =Emil MEM PDF 2U- INOWIWININ NAM IN .'74.I9 •76,11 -r BATTERY 1D 11'1 1 (St INNHIWNWIN '177 •1 , i/h 111411111111 1\11!1..■ o. 1 1V111;) __..... IWINNIMINI M- -- U IWOWSZNII marro 'I 7'7.12 177,13 177 14 '117 15 I 177.10 1 /8,12 INHININ SWIN-IN Na- 1 40 1D F® 777 4.. '1 0 174.11 '1 17.4. 'I SSW M111-INIONINIWNI “1 I BATTERY 1C 12 I . 171E'; .14 '1 SN1N - 101 - 611 .- 404 1151 IVO IN- IN- OWNII-NW ELEC. ROOM M I t) IWOWNI '175.14 BATTERY 1B tvl (01-0.10-10- 175 .15 MIN IN NI NO INFIWINIifk MEMO* IN IN INAN '1 112 .12 173.'1'3 4 414 17'5 72. 10 172,1 '1 '172.12 172.'1 5 172.14 1 7:2,15 OWINHIENWIN 11141 NINNOWNWININOWNWN11111161 • OM MINFINHIN 7. PROVIDE PIPE SUPPORT FOR CHS AND CHR PIPING INSTALLED BELOW RAISED ACCESS FLOOR. REFER TO DETAIL 6, SHEET M-8 FOR PIPING SUPPORT DETAIL. 8. REMOVE CHILLED WATER SUPPLY AND RETURN BRANCH LINES BACK TO LOOP AND CAP TO ALLOW FOR WALL CONSTRUCTION. 9. COORDINATE WITH ELECTRICAL CONTRACTOR TO INSTALL GROUNDS FOR PIPE WALL PENETRATION AT THIS LOCATION. REFER TO ELECTRICAL DRAVVINGS. 10. CONTRACTOR TO INSTALL A WATER TIGHT DRIP ENCLOSURE BELOW EXISTING CRAC UNITS. ENCLOSURE TO BE CONSTRUCTED OF 18 GAUGE GALVANIZED STEEL ANGLES WITH ALL WELDED JOINTS. ENCLOSURE SHALL BE 2" DEEP AND EXTEND 2" BEYOND THE PERIMETER OF THE CRAC. TOP EDGES SHALL BE HEMMED OR ROLLED FOR SAFETY. EPDXY PAINT ENTIRE AREA WITHIN THE ENCLOSURE WITH SHERVVIN WILLIAMS ARMOSEAL 1000HS-SW 1006 OR APPROVED EQUAL. REFER TO DETAIL 3, SHEET M-9. CONTRACTOR SHALL INSTALL WATER LEAK DETECTION CABLE SERPENTINED IN DRIP PAN BELOW UNIT. CONNECT THE WATER LEAK DETECTION SYSTEM TO THE CRAG CUSTOM ALARM TERMINAL AS INDICATED BY DETAIL 2, SHEET M-9. 46.16 176,16 IIIMASINN• !vl 17.4.14 1 '1 4,10 -10411-MAIM WM= MIN NIHISHWIWIII St MIN NI IWO- IN NFO.1 , 5) REFER TO M-3 FOR CONTINUATION (/ 3) BATTERY 1A M ID MiD asalarat-ai aa salaam awaalia 172, 12 I i75:17• I 175.16 1911111 ..?3.16 AN MAIM au i42.12 172.17 iIs,iii -151411-10- wwww1 •Fmpl. MIME UPS-1 MO 1 3 RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS CHS/C R 0 0 NEW PDU 150 KVA NEW PDU 00 150 KVA RELOCATE EXI WATEF MAINS - NEW R CKS - IN TING CHILLED 0 ALLOW FOR TALLATION " - A OA 111*2 WM 11 El id lel 1 11 E1 0 43. 4 3. 43, EX. 6" c IS/CHR iii. PDF NEW 6" CHR/CHS REFER DETAIL 4, SH } ET M -8 '44174AIRIFIFIAlrinwirlIfinf 0 0 CH; 144.10 143.16 142.16 144.17 144.18 143.17 143.1 /// .///////,///,' 142.17 142.18 NEW PDU 150 KVA . 6" CH (CHR - z EXIST. 6" CHS/CHR � / / 1 4 1 V • • r 0 0 3 M-8 p. 0 0 --- 1----L_ Mir cI ft c L I I l 1 K or _. , -bp 7ir 74.701,0174W 167.01 365.01 _.. 167.02 167.03 NEW PDU 150 KVA _1 NEW PDU 150 KVA / R LOCATE EXIST' G C A CUM TO - ALLOW FOR WALL COPSTRUCT ON l=l 1 . 1010011121 I 0101112 N- 1111. .101 101011001110 1101111•r 169 . 14 100 '15 1i) 16 1 69 17 169 ; 1 l , 1 j a,1' {,14 I 11;!3.1 1. i,;i III s(3,1 01 101.10 10-i11 01101 - rya - r /4 1 1.1 1 Mr FAD ‘4P1 WI Ft a. TO 10 ■101. I 1:1 Y111- YF1111 MATCHLINE EX, 6" CHS AND CHR MAIN BELOW RAISED FLOOR 1. ■ - Irl I.00PJ GENERAL NOTES: 01; (.:11) awrrafrrdeem FUTUR PDU r 01F10 1 CI .63 REFER TO M -4 FOR CONTINUATION 119 111111111111 1 1;i (11 arA . .. . 111rat.aE 0111111 c raw t (1 I 1 "d.i:?. 113.0 'I Ji'1. r - 112 . r DESIGNATE 60% PERFORATED AIR TILE. REFER TO ARCHITECTURAL SPECIFICATION. - 10 - 10 . 1191 011 1-®e 01140 #01 01.01 YQi 6{01 w 10 eYFr- r 1-r 001 111110 IlelF01 - 110 01 - rr 1411 01 r 011 1111-011 1 467.0 1 11'3 ('I 1•111 1:111.111 l iIi I.1IIb 1 4II Qk 11rr.'id.i 1111 ?'1'i I `1I i;; I 1.1t; I :3 10- IIL IN 011-10-01 fYI 6101 01-010 i I 'i 01-101-1010 2. CONTRACTOR SHALL PROVIDE QUANTITY OF PERFORATED RAISED FLOOR TILES AS INDICATED ON DRAWINGS. CONTRACTOR SHALL INSTALL PERFORATED FLOOR TILES AS DIRECTED BY VERIZON BUSINESS REPRESENTATIVE AND SHALL PROTECT AND STORE REMAINING PERFORATED FLOOR TILES ON SITE AS DIRECTED BY VZB FOR FUTURE INSTALLATION. 3. AFTER ALL WORK IS COMPLETE, CONTRACTOR SHALL REMOVE ALL CONSTRUCTION TRASH AND DEBRIS AND VACUUM CONCRETE SURFACE BELOW RAISED FLOOR TO INSURE ENTIRE AREA BELOW RAISED FLOOR IS LEFT CLEAN AND DUST FREE. 4. CONTRACTOR SHALL PROVIDE DIELECTRIC FITTINGS OR FLANGES AS SPECIFIED WHERE CONNECTING DISSIMILAR PIPING MATERIALS AND METALS. 5. CONTRACTOR SHALL HAVE THE OPTION TO SHOP FABRICATE PIPING OFF SITE IN 10 FEET OR SHORTER LENGTHS WITH FLANGED ENDS. PIPING MAY BE DELIVERED AND ASSEMBLED WITH BOLTS AND GASKETS ON SITE FOR FINAL INSTALLTION. EXISTING CONDITIONS NOTE: 1. EXISTING CONDITIONS AS INDICATED ON THESE DRAWINGS WERE TAKEN FROM THE OWNER'S RECORD DRAWINGS AND /OR SITE V ISITS AND ARE PROVIDED TO THE CONTRACTOR AS AN AID IN ASCERTAINING THE SCOPE OF HIS WORK. NEITHER THE OWNER, THE ARCHITECT, NOR THE ENGINEER GUARANTEES THE ABSOLUTE ACCURACY OR CONDITIONS INDICATED HEREIN, VARIATIONS OF THE EXISTING CONDITIONS FROM THAT INDICATED ON THE DRAWINGS COULD IN ALL PROBABILITY OCCUR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE JOB SITE PRIOR TO THE BID TO MAKE INVESTIGATIONSNERIFICATIONS AS NECESSARY TO DETERMINE THE COMPLETE EXTENT OF THE WORK REQUIRED. THE CONTRACTOR SHALL ADVISE THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES PRIOR TO SUBMITTING HIS BID, AFTER BID DATE, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE COMPLETE, OPERABLE SYSTEMS AND CONSTRUCTION PER PLANS AND SPECIFICATIONS ALL AT NO ADDITIONAL COST TO THE OWNER OR ARCHITECT /ENGINEER. .2 - 0111 la 'i 11s. ��r,��- r��r � ��r�..rr�. � ! I_ WI ' 01 - IaF01 - MUM kPru® I.:i ,' I'1 10-110-10 11 SUN 1040 - 10r 01 *01 i ` I1 148.1 146. 110 •I:'i '1 d:i I i 1 01-1111 r ®11 1- r 101111 • - ar1111 "11 „ 1 , e I :i n• 1--w 1-- WA au 1111 - 10-11111 tS1 r IN r " 1 46.1L 111 8) '16 /CHR- EN rr0 'I (-1 IiF'r bFi�r_ - - I + � i;; Iia 101 146.17 i SCALE: 1/4" = 1' -0" I � CORRIDO PARTIAL FIR8T FLOOR PLAN - HVAC NOTES INDICATED BY NUMBER IN 1. CHILLED WATER PIPING BELOVy RAISED ACCESS FLOOR, VERTICALLY STACKED WITH 6" CHILLED WATER SUPPLY ON TOP, 6" CHILLED WATER RETURN AT BOTTOM TO MATCH EXISTING. 2. MAINTENANCE WINDOW WORK: FREEZE LINE AT THIS LOCATION AND INSTALL ISOLATION VALVE WITH BLIND FLANGE IN BOTH CHILLED WATER SUPPLY AND RETURN LINES. 3. ISOLATE FLOW IN THIS PIPE S BY CLOSING THESE VALVES HERE AND AT THE EXISTING NORTH ISOLATION VALVES (REFER TO SHEET M -4) TO ALLOW FOR THE RELOCATION OF THE 6" CHILLED WATER SUPPLY AND RETURN LINES AS INDICATED. 4. CONNECT NEW 6" LINES TO EX STING. 5. RECONNECT EXISTING CRAC 26 TO NEW 6" CHILLED WATER LOOP. PROVIDE NEW 2" TAPS. REFER TO TYPICAL CRAG UNIT CONNECTION DETAIL, SHEET M -8. 11 LOOP EXISTING CHILLED WATER NEW C RAC UNITS T9 EXIST 6. CONNECT UTILIZING EXISTING 2" TAPS. EXTEND NEW 2" RUNOUTS FROM EXISTING VALVES AND CONNECT TO UNITS. REFER TO TYPICAL CRAG UNIT CONNECTION DETAIL, SHEET LINES CONTINUE ON SHEET M -4 "----- WITH ISOLATION VALVES AT TOP �I.. -1',1 • -r 01.0 * 10 rr FUTURE I PDU -... ara wig r 169 .02 ' 1 "Y 11 (.. .11 .01 .01. r. m ®fmr►P`� 09 FUTUR PDU SOUTH 159 03 rriar 160.1 0 161). I 1 :10,\''> iu w0 -r ra- I rts'`;f': a9 tlYrsamw 100.03 01- r -rrnrr 110a0 Fj / 1 ,0.1) }3' 10 - 011 - 10 . '20 ao-r•r-11- � r4r.10r.5a r -r•r11-10 109 07 100.01' 169. 09 613,03 in r it l+r CORRIDOR ®Fr-r r -ar110 ralo atr -r- i 7. NEW CRAC UNIT. INSTALL UNIT ON FACTORY FLOOR STAND TO MATCH HEIGHT OF EXISTING RAISED ACCESS FLOOR. FLOOR STAND SHALL BE RATED FOR MOUNTING OF UNIT IN SEISMIC ZONE. INSTALL LEAK DETECTION CABLE SERPENTINED BENEATH UNIT. CONNECT NEW CRAC UNITS TO EXISTING. CSI/TAC BUILDING AUTOMATION SYSTEM UTILIZING EXISTING SITELINK PANEL (BY OTHERS). 8. EXISTING CRAC AND ACCESSORIES AT NEW LOCATION. RECONNECT CHILLED WATER SUPPLY AND RETURN LINES FROM NEW PORTION OF LOOP PIPING WITH NEW 2" RUNOUTS. RECONNECT UNIT'S CONTROL WIRING. REFER TO PLUMBING DRAWINGS FOR CONDENSATE DRAIN LINE AND HUMIDIFIER WATER MAKE -UP PIPING. 9. COORDINATE WITH ELECTRICAL CONTRACTOR TO INSTALL GROUNDING FOR PIPE WALL PENETRATION AT THIS LOCATION. REFER TO ELECTRICAL DRAWINGS. 10. EXTEND NEW 2" RUNOUTS FOR NEW PORTION OF CHILLED WATER LOOP. REFER TO TYPICAL CRAG UNIT CONNECTION DETAIL, SHEET M -8 FOR PIPING CONNECTION. _ 11. PROVIDE PIPE SUPPORT FOR CHS AND CHR PIPING INSTALLED BE LOW RAISE ACCESS FLOOR. REFER TO DETAIL 4, SHEET M -8 FOR PIPING SUPPORT DETAIL. REFER TOM 4 FOR CONTINUATION ,.+ - -- '1 ii.. '1 k i-,U /01-1111 r - 101r1Ell 01 01 arrrr '1 1,0 . 11 16'6,11 18(.3.'1 { 4 4 - 1 0 9 .11 2 -+� 'ISO. 73 70 1 -110- r-W-WYr SPECIFIED. r r as r r at01.01 - ®1 - Mod- 0(3 MATCHLINE If" ottipapAc pE* F 3 1 q 7 01■ col OlTulisilla 39:11.01G SION 12. CONTRACTOR SHALL PROVIDE A WATER TIGHT DRIP PAN BELOW CRAG. DRIP PAN SHALL BE INSTALLED O N CONCRETE FLOOR BELOW FLOOR STAND. DRIP PAN SHALL BE CONSTRUCTED OF 18 GAUGE GALVANIZED STEEL WITH ALL WELDED JOINTS. THE DRIP PAN SHALL BE 2" DEEP AND EXTEND 2" BEYOND THE PERIMETER OF THE CRAG. TOP EDGES SHALL BE HEMMED OR ROLLED FOR SAFETY. CONTRACTOR SHALL INSTALL WATER LEAK DETECTION CABLE SERPENTINED IN DRIP PAN BELOW UNIT. CONNECT THE WATER LEAK DETECTION SYSTEM TO THE CRAC CUSTOM ALARM TERMINALS AS INDICATED BY DETAIL 2, SHEET M -9. 13. CONTRACTOR TO INSTALL A WATER TIGHT DRIP ENCLOSURE BELOW EXISTING CRAC UNITS. ENCLOSURE TO BE CONSTRUCTED OF 18 GAUGE GALVANIZED STEEL ANGLES WITH ALL WELDED JOINTS. ENCLOSURE SHALL BE 2" DEEP AND EXTEND 2" BEYOND THE PERIMETER OF THE CRAG. TOP EDGES SHALL BE HEMMED OR ROLLED FOR SAFETY. EPDXY PAINT ENTIRE AREA WITHIN THE ENCLOSURE WITH SHERWIN WILLIAMS ARMOSEAL 1000HS -SW 1006 OR APPROVED EQUAL. REFER TO DETAIL 3, SHEET M -9. CONTRACTOR SHALL INSTALL WATER LEAK DETECTION CABLE SERPENTINED IN DRIP PAN BELOW UNIT. CONNECT THE WATER LEAK DETECTION SYSTEM TO THE CRAG CUSTOM ALARM TERMINAL AS INDICATED BY DETAIL 2, SHEET M -9. 14. REMOVE EXISTING DAMAGED PIPE INSULATION AND PROVIDE NEW PIPE WARP LA FEB 0.5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS II 4i 2 3 4 }\ j) 0 r•1110_ 01 -05 -09 01 -15 -09 01 -26-09 02 -02 -09 1 Lin W :win: I w ' o kl aim ; AO W ck �Wo 1 gz7 > . W'16 1 Z 01 N ©< 52 k z � � a� Q i O co 8 izo L i---- 4 Q CD Q C( l'444 k c ( Lu 4 `C k 1..... k 1 . LLI (D .;' 4 N W U) cb (f) wrz) Revision Sheet No. Fac. Code:TYKWWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, Z Proj. Mgr.: KCM Date: 12 -12 -08 95% REVIEW 100% CD ADD. NO. 1 PERMIT SET Project No. WTA. 08093 IVI 3 PARTIAL FIRST FLOOR PLAN - HVAC - SOUTH "M7.1, 1. T.,,, . _ 6 . ,u,..., .7,;.. F::'..l".(,....4,... : 7'`,;';',''';4,,7,''.' • ) , U E5CJ T; E.,17 N. 5 0.1 Ur.1.40-1 P.M... ' _ ( ,....— 0 . • 1 ', .. "M7.1, 1. T.,,, . _ 6 . ,u,..., .7,;.. ' ;e . ; 1 :1 ,- ,!,',. ,. .q. ' ,;.,;( , , V - ..iM 1 - ‘,, oi..KM17 1..• ..:13:. 4.4-1M1M15,-.1,4',Vyr;;;;;V;;,?4;M1..?:...0.;,..,M1'.:-...j.t.Wfi.,-...;:' c....1M1.14 s.cuou.,M1u14 DU.t.Ut TANK E.,17 N. 5 0.1 Ur.1.40-1 P.M... ' ( 1V ) - ELEC C) F F ICE OFFICE SCALE: 3/32" =1 S110 RAG E OPEN OF F ICE 1 f,) (4; t TICE C BR EAK R 0 OM OEFICf.. HSS PAN L ,;" 0 F F I (M1/ E SECURITY PANEL --- - - - ' _L-..=.-2._-_-tt:==:_-_-- -=-2 1 OFFICE PARTIAL MEZZANINE FLOOR PLAN REFER TO SHEET E-5, E-10, DC-5, AND DC-8 FOR WORK IN THIS AREA. FIRE PANEL =72 .. . BMS PANEL ) ( (rM1 rf.) 0 REFER TO SHEET M-5 AND E-7 FOR WORK IN THIS AREA. S TO RAG LOADING DOCK r ../. .....th, _,..... E........,...„ vEsT VVt 1".] EXISTING AIR COLED CHILLER #1 VT; 'LCHS AB 'V LV PUMP ' 0 E N E N ADMIN. • { CHILLER YAR Irian, 1 1;66,4U/07En+ VVi I OM. IP wrr,,,Elf DAFICIIM1 KM141.P1.,-111 II r ,-• ( (51 1 1 , 1_ 'fr" • i WoLRIFf., VVVV “IF CH— EXISTING AIR COOLED CHILLER #2 I ND Et 1 L - r B I 1172r1,..M11,4 UM1,1% . — 11.,, _ STAIR di .D0 S. 1 BOVE,- - LOW SCALE: 3/32” = NEW AIR COOLED CHILLER #3-08 1lEf f. FIL !MCI IILL r. mwska,imt .611 lorrarwsruirvonar lala RF.C1. IM1E.31 1 r gi t't - 'lit tt• S 1' • 7 11,1 t 171. I s '17' VVVVV VVV I VV I "I • VVVV VI VI I VI VI " I V V -t REC r VVVVV I I I I 11;:(11 41.P. Vi NOTES INDICATED BY NUMBER IN 1. SMOKE DETECTOR LOCATOR DRAWING. CONTRACTOR SHALL MODIFY AND UPGRADE DRAWING TO SHOyV NEW EQUIPMENT ROOM WITH ANY APPLICABLE CHANGES. E E RAT 0 R ENCLOSURE P C)WE R ROoM P N KLER IL V ROOM — ,.. RAMP 1.67029 42000 14E01 11E70 lion' 1 116e.r. RECT. XLM11 ;,w, ACUT. REcl. ill. I 11E.M11 1166, fiEC f ' ' 1400 j Yoriddir ur raw ear war vut AWL ZUw2-120M1 114 IV 4)14 461 f.1 TRAN SF OR E RS .4Wr 14/.17 I II I ""- I I L- _J 2:: I 101444 :11E3.1,4krit, [141r 51-61,” 34 000V14 0011111 I t IV r 0 I iV 4 4 -4 41'"'wil w77.1C .4 VV 4 FUTURE UPU 11,1 cPILB 1.1Ia CORRIDOR VVJ I-: I F V f OVERALL FLOOR PLAN - MECHANICAL AND V V ELECTRICAL 1:111 ,7111w.33.14 NEW POU 1601iVA 10:4 uM11.U1 1- `1X :_. _1 itM 01 1,10 6100 NEW OW 150 KVA 114000 . .M1*61.1. r 167.,1 6,06 157 9, 1120> 12010 An: oz. 0■4 us.; al 10140. .1 Ft EC'FRI L 6 10.6.0M1 l 0 U611 tr.,. 1, VIII 44>4 . i r 141,, 111.11 151.14 1001> 0 !II 1M1 UV, 1 14/ 15 wu 11121 LIII 41..406 110M1, 1474/:La,r.tle MO. 1101 riNEU.w. ; • I2,11 013:40> ULM MU,SK2EA Ill ,1 I VII U1,1 AGCESSIBLE • arUM11M VV 1 ' I trelltt tw-.11 vol. .1 IS VVVVVVVVV V ) J — P:4 t: id V Mtt: REFER TO SHEET E-6 FOR WORK IN THIS AREA. vtoc 1 REFER TO SHEET M-4, P-4, FP-2. FP-4, E-4, E-9, DC-2, DC-4, AND DC-7 FOR WORK IN THIS AREA. REFER TO SHEET M-3, P-3, FP-1, FP-3, E-3, E-8, DC-1, DC-2, AND DC-6 FOR WORK IN THIS AREA. ezVitvvw CODE COMPLIANCE APPROVED FEB 1 9 2009 City OfTukwila _MING MEW RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT 0 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 ../ 1-1 3 Lk' 01-05-09 01-15-09 01-26-09 02-02-09 Exp ire s IVIRO Fac. CodeJYKVVWA Drawn By: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 1212-08 Revision 95% REVIEW 100% CD Project No. MA. 08093 Sheet No. ADD. NO. PERMIT SET MPE-2 OVERALL FLOOR PLAN - MECHANICAL AND ELECTRICAL SECTION NUMBER SHEET SECTION IS LOCATED ON HVAC SYMBOL LEGEND SYMBOL 1CD r CD '0i x 1 D4 CHS CHS CHR CHF --•- CRAC # DESCRIPTION EXISTING CONDENSATE DRAIN LINE (SLOPE IN DIRECTION OF ARROW) NEW GRAVITY CONDENSATE DRAIN PIPE (SLOPE IN DIRECTION OF ARROW) PIPE ELBOW TURNED DOWN PIPE ELBOW TURNED UP PIPE TEE TURNED DOWN PIPE TEE TURNED UP PIPE ANCHOR UNION OR FLANGE FLEXIBLE PIPE CONECTION ARROW INDICATES DIRECTION OF FLOW VIBRATION ISOLATOR ISOLATION VALVE CHECK VALVE SIGHT GLASS PRESSURE GAUGE W /GAUGE COCK. EXISTING CHILLED WATER SUPPLY NEW CHILLED WATER RETURN EXISTING CHILLED WATER RETURN NEW CHILLED WATER RETURN TEMPERATURE AND PRESSURE TEST PORT BALANCING VALVE, PLUG TYPE BALANCING VALVE, CIRCUIT SETTER TYPE AUTOMATIC FLOW REGULATOR TRIPLE DUTY VALVE SECTION IDENTIFICATION SYMBOL COMPUTER ROOM AIR CONDITIONER DESIGNATION PLUMBING, SYMBOL LEGEND SYMBOL ICW ICW SS ICW CD I PCD G 0 (� LINE SIZE BALL VALVE CHECK VALVE C CAPPED CONNECTION VTR BFP FD — —FOV — — FOS FOR DESCRIPTION DOMESTIC COLD WATER PIPE EXISTING DOMESTIC COLD WATER PIPE EXISTING INDUSTRIAL COLD WATER INDUSTRIAL COLD WATER DRAIN AND WASTE PIPE EXISTING STORM SEWER LINE EXISTING DRAIN AND WASTE PIPE HUMIDIFIER MAKE -UP PIPE CONDENSATE DRAIN PIPE (SLOPE IN DIRECTION OF ARROW) PUMPED CONDENSATE DRAIN PIPE VENT PIPE EXISTING VENT OR REVENT PIPE EXISTING GAS PIPE PIPE ELBOW TURNED DOWN PIPE ELBOW TURNED UP PIPE TEE TURNED DOWN PIPE TEE TURNED UP UNION OR FLANGE CLEAN OUT (F.C.O. - FLOOR CLEAN OUT) (W.C.O. - WALL CLEAN OUT) VENT THROUGH ROOF BACK FLOW PREVENTER FLOOR DRAIN FUEL OIL VENT PIPE FUEL OIL SUPPLY PIPE FUEL OIL RETURN PIPE ARROW INDICATES DIRECTION OF FLOW SYMBOL P SD DESCRIPTION AUDIOVISUAL ALARM APPLIANCE MANUAL FIRE PULL STATION EXISTING SMOKE DETECTOR NEW SMOKE DETECTOR EXISTING UNDERFLOOR SMOKE DETECTOR NEW UNDERFLOOR SMOKE DETECTOR EXISTING HEAT DETECTOR NEW HEAT DETECTOR SYMBOL m t o 3(; N DUPLEX TELEPHONE JACKS (VOICE AND DATA) - WALL MOUNTED G.F.I. W.P. EUES U ES ^, UEP UES DESCRIPTION MANUAL MOTOR STARTER SPST WALL SWITCH (SWITCHING FIXTURES WHERE "a" IS INDICATED) 3 -WAY SWITCH NARROW MULLION SWITCH DUPLEX RECEPTACLE - IN WALL L5 -20R RECEPTACLE L6 -30R RECEPTACLE ELECTRIC MOTOR (5 HP INDICATED) HP RATED DISCONNECT SWITCH SURFACE MOUNTED PANELBOARD RECESS MOUNTED PANEL JUNCTION BOX WITH COVER GROUND FAULT INTERRUPTOR GROUND FAULT "W.P." BY ANY ELECTRICAL DEVICE SYMBOL INDICATES THAT THE DEVICE IS TO BE WEATHERPROOF CONDUIT "HOME RUN" TO PANEL (HASH MARKS INDICATE THE NUMBER OF CONDUCTORS FLUORESCENT LIGHTING FIXTURE (TYPE "A ") CEILING MOUNTED EMERGENCY FLUORESCENT LIGHTING FIXTURE CEILING MOUNTED DOWNLIGHT FIXTURE /CEILING MOUNTED GROUND LEAD. REFER TO GROUNDING PLAN AND GROUNDING LEAD LIST SCHEDULE WALL MOUNTED LIGHT FIXTURE EXISTING UNDERGROUND ELECTRICAL SECONDARY NEW UNDERGROUND ELECTRICAL PRIMARY (PAVED SURFACE) NEW UNDERGROUND ELECTRICAL SECONDARY (PAVED SURFACE) NEW UNDERGROUND ELECTRICAL PRIMARY (EXPOSED EARTH SURFACE) NEW UNDERGROUND ELECTRICAL SECONDARY (EXPOSED EARTH SURFACE) MOOl3 IOW tiiK i\\\ � E. COMPf 3NACE AIPPROV'E FE B 19 2009 ----- 20-0-1NGD SI0 RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT CQ 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS 2 3 4 3 )fires O go„ o � qc � Lu cp co W cf) N (i) o tor. o O tl W ��(1 rn N w r W ..r rwoW W CI wm Wo Jr- 5 r W ZUIN oQM Fac. Code:TYKWWA Drawn Sy: IM, PS, ZJ Designed By: KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 12 -08 Revision 01 -05 -09 01 -15 -09 01 -26 -09 02 -02 -09 t 95% REVIEW 100% CD Sheet No. ADD. NO. 1 PERMIT SET Project No. WTA. 08093 MPE -1 MPE SYMBOL LEGENDS C EXISTING BUILDING 1 GATEWAY DR. SOUTH 00 00 00 00 00 00 00 SEE PARTIAL FLOOR PLAN FOR NEW WORK IN THIS AREA SEE PARTIAL EGRESS FLOOR PLAN SHEET A -1.1 PA rv1 TART n tivi LA,.! CODE INFORMATION APPLICABLE CODES: 2006 INTERNATIONAL BUILDING CODE (IBC) 2006 INTERNATIONAL MECHANICAL CODE (IMC) 2006 INTERNATIONAL PLUMBING CODE (IPC) 2006 NATIONAL ELECTRICAL CODE (NEC) 2006 INTERNATIONAL FIRE CODE (IFC) WASHINGTON STATE BARRIER FREE REGULATIONS LATEST EDITION FEDERAL GUIDLINES AMERICANS WITH DISABILITIES ACT (WAC 51 -20) BUILDING INFORMATION: CONSTRUCTION TYPE: OCCUPANCY: EXIST. BLDG. AREA: TENANT IMPROVEMENT AREA: TELECOMUNICATION EQUIP. AND SUPPORT EQUIPMENT ALLOWABLE FLOOR AREA: FIRE RESISTIVE REQUIREMENTS: EXTERIOR NON - BEARING WALLS INTERIOR BEARING WALLS STRUCTURAL FRAME FLOORS ROOF SHAFTS STAIR ENCLOSURES V -N (SPRINKLED) B 70,775 S.F. 9,800 S.F. NON -RATED NON -RATED NON -RATED NON -RATED NON -RATED NON -RATED NON -RATED PROJ. NORTH UNLIMITED PER SECTION 507.4 AUTOMATIC SPRINKLERS THROUGHOUT 60' PUBLIC WAYS ON 4 SIDES SITE PLAN SCALE: 1" = NORTH VICINITY MAP NO SCALE IA) tiS APPP R EV '1° RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT Q 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS Fac. Code:TYKWWA Drawn By: Designed By: Proj. Mgr.: 2 4 ONE VILLAGE DRIVE, SUITE SOO Aka IL-EN G. - XA9 798D I3Z5I 695.1090 FAA 03351 695 -1 ❑98 I l sIZIC \ Mv# (Tc; 7 0 cr Lil (D c' O Date: 02-02-09 Revision 01 -05-09 01 -15 -09 02 -02 -09 Sheet No 95% REVIEW 100% CD PERMIT SET Project No, WTA. 08093 A -1.0 ARCHITECTURAL SYMBOLS AND NOTES DRAWING INDEX & STATUS LEGEND: SHEET ISSUED FOR CONSTRUCTION ISSUE / REVISIONS 1 2 3 4 5 6 ►�! SHEET ISSUED FOR INFO. & COORDINATION I V I SHEET VOIDED w ill ee gl- in 0) 0 Q o U o c) I- 0 -. o O c of < 0) N ' � w w g c/ w d a Q n ' a ■ 01 -26 -09 SHEET NUMBER SHEET TITLE DRAWING ISSUE DATE -02 -09 MECHANICAL - PLUMBING - ELECTRICAL (CONTINUED) E -8 PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - SOUTH 12.12.2008 ARCHITECTURAL A -0.1 ' f Kt• 12.12.2008__ 12.12.2008 F3i E -9 E -10 PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING - NORTH PARTIAL FIRST FLOOR PLAN - ELECTRICAL LIGHTING- POWER ROOM 12.12.2008 E-11 ELECTRICAL ONE LINE DIAGRAM E -12 UPS WIRING DIAGRAM AND FEEDER TABLE 12.12.2008 A -1.1 E -13 ELECTRICAL PANEL SCHEDULES 12,12.2008 l- . -; PARTIAL FLOOR PLAN 12.12.2008 E -14 ELECTRICAL PANEL SCHEDULES 12.12.2008 A -3.1 A -4.1 ARCHITECTURAL DETAILS 12.12.2008 E -15 ELECTRICAL PANEL SCHEDULES 12.12.2008 I DOOR AND FINISH SCHEDULE E -16 ELECTRICAL PANEL SCHEDULES 12.12.2008,. 12.12.2008 12.12.2008 • , `s p L ; -- E -17 ELECTRICAL DETAILS 12.12.2008 E -18 FIRST FLOOR PLAN - ELECTRICAL GROUNDING E -19 GROUNDING SCHEMATIC 12,12.2008 E -20 GROUNDING DETAILS 12.12.2008`; #° 12.12.2008 D.C. POWER DC-1 PARTIAL FIRST FLOOR PLAN - COMMUNICATION CABLE LADDER - SOUTH 12.12.2008 (.0 Cs? I , PARTIAL FIRST FLOOR PLAN - HVAC - NORTH 12.12.2008 12.12.2008 ' aer • • t , !!• • :#11 ,,, ;4= - 7:7-rt —, : ••••-- • , ;( t ° i DC -2 PARTIAL FIRST FLOOR PLAN - COMMUNICATION CABLE LADDER- NORTH PARTIAL FIRST FLOOR PLAN - POWER CABLE LADDER - SOUTH 12.12.2008, PARTIAL FIRST' FLOCR PLAN- MECHANICAL ROOM AND CHILLER YARD CHILLED WATER PIPING SCHEMATIC 12.12,2008 �.� _ CHILLED WATER PIPING SCHEMATIC 12.12.2008 DC -3 12.12.2008 12.12.2008�,n DC -4 PARTIAL FIRST FLOOR PLAN - POWER CABLE LADDER - NORTH DC -5 PARTIAL FIRST FLOOR PLAN - POWER CABLE LADDER - POVVER ROOM 12.12.2008 P -3 PARTIAL FIRST FLOOR PLAN - PLUMBING - SOUTH DC-6 PARTIAL FIRST FLOOR PLAN - FRAMEWORK GROUND - SOUTH 12.12.2008 P -4 PARTIAL FIRST FLOOR PLAN - PLUMBING - NORTH - 12.12.2008 DC -7 DC-8 PARTIAL FIRST FLOOR PLAN - FRAMEWORK GROUND - NORTH PARTIAL FIRST FLOOR PLAN - FRAMEWRDRK GROUND - POVVER ROOM 12.12.2008 12.12.2008 E -3 PARTIAL FIRST FLOOR PLAN - ELECTRICAL POWER - SOUTH 12.12.2008 ; DIAGRAM E -4 €C „• 7 r Aii DC -10 UPS 480V. D.C. ONE INE DIAGRAM AND BATTERY RACK DETAILS 12.12.2008, FP -1 FIRE PROTECTION PARTIAL FIRST FLOOR PLAN- FIRE ALARM AND SPRINKLER SYSTEM SOUTH 12.12.2008 PARTIAL FIRST FLOOR PLAN - ELECTRICAL ROOM AND COURTYARD ,ELECTRICAL PARTIAL FIRST FLOOR PLAN - CHILLER YARD AND PUMP ROOM, ELECTRICAL 12.12.2008 12.12.2008 F P -2 FP -3 PARTIAL FIRST FLUOR PLAN - FIRE ALARM AND SPRINKLER SYSTEM - NORTH 12.12.2008, PARTIAL FIRST FLOOR PLAN - FIRE ALARM - BELOW RAISED FLOOR -NORTH 12.12.2008 x ' �r F P -4 PARTIAL FIRST FLOOR PLAN - FIRE ALARM - BELOW RAISED FLOOR - NORTH 12.12.2008 ,', ", DRAWING INDEX & STATUS LEGEND: SHEET ISSUED FOR CONSTRUCTION ISSUE / REVISIONS 1 2 3 4 5 6 ® SHEET ISSUED FOR INFO. & COORDINATION I V I SHEET VOIDED .° rn 0 o Q 8 0) - ZS 0 < o N Q w E l a 0, 0 o 01 -26 -09 SHEET NUMBER SHEET TITLE DRAWING ISSUE DATE -02 -09 REFERENCE C -1 COVER SHEET 12,12.2008 'Pi' ' ' ARCHITECTURAL A -0.1 ARCHITECTURAL SYMBOLS AND NOTES 12.12.2008 , " A -1.0_ SITE PLAN 12.12.2008 �'' '`' - - A -1.1 �- EGRESS PLAN p 12.12.2008 A -2.0 PARTIAL DEMO A -2.1 PARTIAL FLOOR PLAN 12.12.2008 ; . ;, A -3.1 A -4.1 ARCHITECTURAL DETAILS 12.12.2008 o ' �:: , .. DOOR AND FINISH SCHEDULE MECHANICAL - PLUMBING - ELECTRICAL MPE -1 MECHANICAL AND ELECTRICAL SYMBOL LEGEND 12.12.2008 • MPE -2 MECHANICAL AND ELECTRICAL OVERALL FLOOR PLAN 12.12.2008 M -3 PARTIAL FIRST FLOOR PLAN - HVAC - SOUTH 12.12.2008 (.0 Cs? I , PARTIAL FIRST FLOOR PLAN - HVAC - NORTH 12.12.2008 12.12.2008 ' aer • • t , !!• • :#11 ,,, ;4= - 7:7-rt —, : ••••-- • , ;( t ° i - rt m PARTIAL FIRST' FLOCR PLAN- MECHANICAL ROOM AND CHILLER YARD CHILLED WATER PIPING SCHEMATIC 12.12,2008 �.� _ CHILLED WATER PIPING SCHEMATIC 12.12.2008 HVAC DETAILS AND SECTIONS 12.12.2008 � ��_ m - - - � HVAC SCHEDULES 12.12.2008 P -3 PARTIAL FIRST FLOOR PLAN - PLUMBING - SOUTH 12.12.2008 a P -4 PARTIAL FIRST FLOOR PLAN - PLUMBING - NORTH 12.12.2008 - 12.12.2008 E -3 PARTIAL FIRST FLOOR PLAN - ELECTRICAL POWER - SOUTH 12.12.2008 ; E -4 PARTIAL FIRST FLOOR PLAN - ELECTRICAL POWER - NORTH 12,12.2008 7 r Aii E -5 E -6 E -7 PARTIAL FIRST FLOOR PLAN - POWER ROOM, ELECTRICAL 12.12.2008 ' � �I M ATet:: rOA 0*. tV. !NT • PARTIAL FIRST FLOOR PLAN - ELECTRICAL ROOM AND COURTYARD ,ELECTRICAL PARTIAL FIRST FLOOR PLAN - CHILLER YARD AND PUMP ROOM, ELECTRICAL 12.12.2008 12.12.2008 Designed By KCM, DL, ZJ Proj. Mgr.: KCM Date: 12 -12 -08 Revision 1 01 -05 -09 95% REVIEW 2 01 -15 -09 100% CD 3 01 -26 -09 ADD. NO. 1 4 02 -02 -09 PERMIT SET Project No. WTA. 08093 Sheet No. c - I COVER SHEET yeni on business QUIPMENT ROOM BUILDOUT AT 12682 GATEWAY DRIVE SOUTH TUKWILA, WASHINGTON SITE CODE: TYK A VERIZON BUSINESS TECHNICAL FACILITIES OPERATION AND CONSTRUCTION 604 EAST HOAG STREET PO BOX 10 YACOLT, WA 98675 VERIZON BUSINESS SR. IMPLEMENTATION ENGINEER LISA H. DAVIE A. DRAWINGS THE WORK OUTLINED IN THIS DOCUMENT SHALL BE PERFORMED IN ACCORDANCE WITH THE VERIZON BUSINESS STATEMENT OF WORK, AND AS INDICATED IN PROJECT DRAWINGS AND SPECIFICATIONS. B. GENERAL REQUIREMENTS 1. THE CONTRACTOR IS TO INSTALL THE EQUIPMENT BASED ON WORKING SHIFTS BETWEEN 8:00 a.m. TO 5 :00 p.m. ON WEEKDAYS EXCEPT WHERE SPECIFIED DIFFERENTLY BELOW. ALL HVAC AND ELECTRICAL HOT WORK HAS TO HAVE A VERIZON BUSINESS APPROVED METHOD OF PROCEDURE (MOP'S) BEFORE ANY WORK CAN TAKE PLACE. 2. ANY WORK REQUIRED OVER ACTIVE VERIZON BUSINESS SWITCH EQUIPMENT OR IN THE VERIZON BUSINESS POWER ROOM MUST BE ACCOMPLISHED BETWEEN 12 :00 a.m. (MIDNIGHT) AND 6 :00 a.m. AND MUST BE APPROVED BY THE SITE MANAGER AT LEAST 24 HOURS PRIOR TO COMMENCEMENT OF THE WORK. ALL ELECTRIC HOT WORK HAS TO HAVE A VERIZON BUSINESS APPROVED METHOD OF PROCEDURE (MOP'S) BEFORE ANY WORK CAN TAKE PLACE. ALL ELECTRICAL MOP HOT WORK SHALL BE PERFORMED WITH 1000 VOLT TOOLS. 3. THIS IS A TRAFFIC- CARRYING, REVENUE- PRODUCING FACILITY WHICH MUST BE FULLY FUNCTIONAL THROUGHOUT THE DURATION OF THIS PROJECT. THEREFORE, GREAT CARE MUST BE TAKEN WHILE WORKING INSIDE THE VERIZON BUSINESS COMPUTER AREA AND THE EQUIPMENT MUST BE PROTECTED FROM DUST AND DAMAGE AT ALL TIMES. 4. WORK TO BE ACCOMPLISHED ON THE EXTERIOR OF THE VERIZON BUSINESS LEASE SPACE MAY OCCUR DURING REGULAR BUSINESS HOURS, SEVEN DAYS PER WEEK. 5. ALL WORK WITHIN THE BUILDING MUST BE COMPLETED ON OR BEFORE CONTRACT DATE, INCLUDING DELIVERY OF THE UNITS, PIPING, SETTING, AND CONNECTING THE HVAC UNITS. SETTING AND RIGGING OF THE NEW LIEBERTS AND AIR COOLED CONDENSERS WILL BE BY THE MECHANICAL CONTRACTOR. 6. THE CONTRACTOR SHALL FURNISH A SCHEDULE OF ALL WORK ACTIVITIES WITHIN THE BID PROPOSAL. 7. THE CONTRACTOR SHALL NOTIFY THE VERIZON BUSINESS PROJECT ENGINEER OF ANY CHANGES TO THIS STATEMENT OF WORK WHICH MAY INCREASE THE AMOUNT OF THE CONTRACT. CONTRACTOR MUST OBTAIN APPROVAL FROM PROJECT ENGINEER PRIOR TO COMMENCEMENT OF ANY WORK NOT INCLUDED IN THE BASE BID. 8. THE CONTRACTOR IS RESPONSIBLE FOR SCHEDULING WITH VERIZON BUSINESS MANAGEMENT FOR ACCESS TO THE BUILDING, FREIGHT ELEVATOR, SECURITY SYSTEMS, TURNING FIRE SUPPRESSION SYSTEM ON /OFF, DELIVERIES TO AND FROM THE BUILDING. UPON COMPLETION OF WORK EACH DAY, THE CONTRACTOR SHALL LEAVE AREAS OF CONSTRUCTION ACTIVITY, DUSTED AND BROOM CLEAN. CONTRACTOR PERSONNEL ARE TO USE EXTREME CARE WHEN USING SHOP VACUUM, INSURING FIRE SUPPRESSION IS DISABLED AND VACUUM DISCHARGE NOT DIRECTED AT ANY SMOKE DETECTORS. TRASH MUST BE REMOVED FROM BUILDING EACH DAY. WHEN APPLICABLE, CONTRACTOR SHALL SCHEDULE ANY WORK DEEMED NOISY OR DISRUPTIVE TO VERIZON BUSINESS PERSONNEL OR SITE OPERATION WITH THE SITE MANAGER OR SUPERVISOR AT LEAST 24 HOURS PRIOR TO COMMENCEMENT OF ACTIVITIES. 10. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, TOOLS, EQUIPMENT AND SUPERVISION TO COMPLETE THE PROJECT WITHIN TIME FRAME SPECIFIED. 11. CONTRACTOR SHALL PROTECT WALLS, FLOOR AND ALL VERIZON BUSINESS PROPERTY FROM DAMAGE. IF DAMAGE OCCURS DURING CONSTRUCTION, CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING TO THE PREVIOUS CONDITION. 12. PROVIDE A SAFETY BARRIER OVER ANY EQUIPMENT IN THE WORK AREA, IF APPLICABLE, OVER SWITCH EQUIPMENT BAYS, TO PREVENT ANYTHING FROM FALLING ON OR INTO THE BAYS. PROVIDE PLYWOOD COVERS OVER THE BATTERIES IF WORK IS OVERHEAD, WITH PROPER VENTILATION. 13. CONTRACTOR SHALL PROVIDE FLOOR PROTECTION WITH 1/2" MASONITE BOARD FOR WORK AREAS AND DELIVERY PATH WHEN SETTING OF EQUIPMENT. CONTRACTOR SHALL PROVIDE FLOOR PROTECTION WITH 1/2" MASONITE BOARD FOR TRAVEL PATH TO AND FROM TOILET ROOMS AND DRINKING FOUNTAINS. SEPARATE PERMIT REQUIRED FOR: 0 MechanIcal e Electrical L Plumbing 3 Gas Piping C;i:% of Tukwila B1..1 DIVISION 14, CONDENSATE DRAIN PIPING AND HUMIDIFIER MAKE -UP PIPING SHALL BE TYPE "L" COPPER WITH 15% SILFOS SILVER BRAZING JOIFrETS. a. PROVIDE AND INSTALL PROPER INSULATION ON PIPING AS SPECIFIED. b. PROVIDE PROPER LABELS ON PIPING AS SPECIFIED. 15. WORK IN HALON PROTECTED AREAS BEFORE WORK CAN BEGIN WITHIN THE FACILITY, THE CONTRACTOR SHALL FIRST DETERMINE THE IMPACT ON ANY HALON - PROTECTED AREA IN MOST CASES, THE HALON SYSTEM SHALL BE DISARMED PRIOR TO COMMENCEMENT OF WORK. AT THE END OF EACH DAY, THE CONTRACTOR SHALL ALSO ENSURE THAT THE SYSTEM IS RETURNED TO NORMAL OPERATION. ALL HALON DUMPED AS A RESULT OF THE CONTRACTOR NOT FOLLOWING THIS DIRECTIVE WILL BE REPLACED BY THE CONTRACTOR AT THEIR EXPENSE. VERIZON BUSINESS WILL NOT PROVIDE HALON FOR THE CONTRACTOR'S USE IN RECHARGING THE SYSTEM. IN THE EVENT THAT DRILLING OR CUTTING IS REQUIRED IN HALON PROTECTED ZONES, THE CONTRACTOR SHALL COVER EVERY HALON SENSOR LOCATED WITHIN 50' OF THE EFFECTED AREA WHILE THE SYSTEM IS DISARMED. THIS WILL ENSURE THAT FOREIGN PARTICLES DO NOT BECOME LODGED IN THE SENSOR, THUS RENDERING THEM INEFFECTIVE OR CAUSING A FALSE ALARM. 16. DRILLING AND CUTTING BEFORE BEGINNING ANY DRILLING OR CUTTING OF CONCRETE, GYPSUM BOARD, OR OTHER DUST - PRODUCING MATERIALS, THE VERIZON BUSINESS REPRESENTATIVE SHALL BE NOTIFIED SO THAT FIRE - PROTECTION SYSTEMS CAN BE DISARMED, AS 'DRILLING OR CUTTING IS REQUIRED IN AN AREA WHERE TELECOMMUNICATIONS EQUIPMENT INS A HEPA VACUUM CLEANER SHALL BE EMPLOYED TO REMOVE THE DUST OR OTHER DEBRIS DURING THE OPERATION. ALL AREAS ABOVE THE CEILING OR UNDER THE RAISED FLOOR SHALL BE VACUUMED CLEAN AFTER THE WORK IS COMPLETE. ALL VACUUM CLEANERS SHALL BE APPROVED FOR USE BY RFEC AND FACILITY MANAGEMENT. WHEN WET CORING, ALL PRECAUTIONS SHALL BE TAKEN TO CONFINE WATER TO WORK AREA ALL EQUIPMENT IN AFFECTED AREAS SHALL BE PROTECTED TO THE SATISFACTION OF THE VERIZON BUSINESS REPRESENTATIVE. ALL CORING LOCATIONS SHALL BE APPROVED BY VERIZON BUSINESS REPRESENTATIVE PRIOR TO BEGINNING THAT WORK. WORKING CONDITIONS C. VERIZON BUSINESS FURNISHED CONTRACTOR INSTALLED LIEBERT CRAC UNITS 1. INSTALL NEW VERIZON BUSINESS FURNISHED LIEBERTS COMPLETE WITH LABOR AND MATERIALS. ELECTRICAL AND CRANE SERVICE, AS REQUIRED! 2. NEW UNITS SHALL BE PIPED WITH HYDRONIC PIPING AS SPECIFIED. a. PROVIDE AND INSTALL PROPER INSULATION. ON CHILLED WATER PIPING AND DRAIN LINE AS SPECIFIED. b. PROVIDE AND INSTALL NECESSARY SERVICE VALVES ON NEW LIEBERT UNITS AS INDICATED AND SPECIFIED. 17. WELDING AND OPEN FLAMES APPROVAL TO DO WELDING SHALL BE OBTAINED; IN ADVANCE FROM THE VERIZON BUSINESS REPRESENTATIVE. NO WELDING SHALL OCCUR WITHIN 5' OF ANY FIXED EQUIPMENT WITHOUT PRIOR NOTIFICATION AND SAFEGUARDS DEEMED APPROPRIATE BY THE VERIZON BUSINESS REPRESENTATIVE. THE VERIZON BUSINESS REPRESENTATIVE WILL COORDINATE DISABLING LOCAL ZONING OF FIRE/HALON SUPPRESSION SYSTEMS AND NOTIFICATION OF SECURITY /SURVEILANCE. 18. CONTRACTOR SHALL PROVIDE AND MAINTAIN TRASH DUMPSTER FOR DISPOSAL OF CONSTRUCTION DEBRIS AND TRASH. TRASH DUMPSTER TO BE REMOVED AT COMPLETION OF PROJECT. PROJECT LOCATION 12682 GATEWAY DRIVE SOUTH TUKWILA, WASHINGTON 5. PROVIDE PROPER LABELS ON PIPING, AS SPECIFIED. 6. COMPLETE ELECTRICAL INSTALLATION TO NEW LIEBERTS AND CONDENSER INCLUDING: a. AC POWER SUPPLY WIRING, CONDUIT AND TERMINATIONS AS INDICATED AND SPECIFIED. b. ALL CONTROL WIRING, CONDUIT, AND TERMINATIONS BETWEEN LIEBERT UNITS, CONDENSERS AND AUTOMATIC CHANGEOVER PANEL AS INDICATED AND SPECIFIED. c. ALL CONTROL INTERLOCK WIRING, CONDUIT AND TERMINATIONS BETWEEN AUTOMATIC CHANGEOVER PANEL AND THE AUTOMATIC TRANSFER SWITCH FOR EMERGENCY POWER OPERATION LOAD SHEDDING AS INDICATED AND SPECIFIED. d. ALL CONTROL INTERLOCK WIRING, CONDUIT AND TERMINATIONS BETWEEN AUTOMATIC CHANGEOVER PANEL AND FIRE SUPPRESSION SYSTEM CONTROL PANEL FOR UNIT SHUT DOWN AS INDICATED AND SPECIFIED. e. COMPLETE WATER TRACE INSTALLATION AND WIRING FROM UNIT TO DETECTOR. f. EQUIPMENT SAFETY GROUNDING TO VERIZON BUSINESS' GROUNDING GRID. a, PROVIDE START -UP CHECK LIST AND SUBMIT COPIES TO CONSTRUCTION SUPERVISOR. D. PROJECT CLOSE OUT 1, CONTRACTOR SHALL ADVISE PROJECT ENGINEER UPON SUBSTANTIAL COMPLETION OF WORK AND SCHEDULE PUNCH LIST WALK THROUGH. 2. CONTRACTOR SHALL COMPLETE ALL PUNCH LIST ITEMS WITHIN 5 WORKING DAYS OF PUNCH LIST WALK THROUGH. 3. FOR DOWN FLOW RAISED FLOOR APPLICATION, PROVIDE RAISED FLOOR PANEL OR RIGID INSULATION IN GAP BEHIND UNIT STAND AND WALL. TO PREVENT SUPPLY AIR LEAKAGE. 4. FOR DOWN FLOW RAISED APPLICATION, PROVIDE PROPER CUT -OUT OF RAISED FLOOR AT UNIT STAND LOCATION. 7. ROOF PENETRATIONS AND PIPE FLASHINGS TO BE INSTALLED BY APPROVED ROOFING CONTRACTOR UNDER MECHANICAL CONTRACTOR BID. WALL PENETRATIONS SHALL BE PROVIDED WITH WALL SLEEVE AND SEALED WATER TIGHT. 9. PROPER LABELING OF ALL NEW HVAC AND ELECTRICAL EQUIPMENT, DISCONNECTS, AND J- BOXES. TO INCLUD a. NEW 1 "X4" BLACK LAMINATE LABELS WITH 1/4" WHITE LETTERS ON LIEBERT UNIT AND CONDENSER. b. LAMINATE LABELS SHALL DESCRIBE UNIT, ELECTRICAL PANEL, AND CIRCUIT DESCRIPTION. c. J - BOXES SHALL BE LABELED SHOWING ELECTRICAL PANEL AND CIRCUIT DESCRIPTION. 10. FOR DOWN FLOW RAISED FLOOR APPLICATION, CONTRACTOR TO INSURE BELOW RAISED FLOOR AROUND NE LIEBERT UNIT TO BE CLEAN BEFORE START -UP. 11. CONTRACTOR SHALL ARRANGE, COORDINATE AND SET UP FACTORY REPRESENTATIVE FOR FACTORY TEST START -UP. By Date: FILE COPY Permit No._ Plan review ' approval is subject to errors and omissions. pp Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of appro . ed Fl d Copy and conditions is acknowledged: � City Of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. COTE: Revisions will require a new plan submittal and may include additional plan review fees. RECEIVED CITY OF TUKWILA FEB 0 5 2009 PERMIT CENTER WTA - 08093 COPYRIGHT 0 2009 WTA, INC. CONSULTING ENGINEERS ABILENE, TEXAS U oIo non N MIN W w0 W big Z >J� i'n" Z , z0 W d ,, ow-a 161 Expires 9..71.10 Fac. Code:TYKWWA Drawn By: IM, PS, ZJ