HomeMy WebLinkAboutPermit M09-019 - NC POWER SYSTEMSNC POWER SYSTEMS
7220 SW 43 ST
M09 -019
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
, doc: IMC -10/06
7220 SW 43 ST TUKW
Contact Person:
Name: JESSE MONTEZ
Address: 7717 DETROIT AV SW , SEATTLE WA
Value of Mechanical: $6,000.00
Type of Fire Protection:
CitAbf Tukwila
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
.Appliance Vent
Repair or Addition to Heat /Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
'Ventilation Fan connected to single duct
'Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
NC POWER SYSTEMS
7220 SW 43 ST , TUKWILA WA
Contractor:
Name: MACDONALD /MILLER FAC SOL INC
Address: PO BOX 47983 , SEATTLE, WA
Contractor License No: MACDOFS980RU
MECHANICAL PERMIT
DESCRIPTION OF WORK:
ADDING TRIPLE DUCTLESS SPLIT SYSTEM WITH REMOTE WIRELESS CONTROLS (1 HEAT PUMP
WITH 3 FAN COIL UNITS)
EQUIPMENT TYPE AND QUANTITY
0
0
0
0
0
0
0
0
0
0
0
0
0
0
* *continued on next page **
M09 -019
Permit Number: M09 -019
Issue Date: 04/08/2009
Permit Expires On: 10/05/2009
Phone:
Phone: 206 768 -4288
Phone: 206 - 768 -4180
Expiration Date: 12/31/2010
Fees Collected: $242.81
International Mechanical Code Edition: 2006
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 - HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment
Printed: 04 -08 -2009
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
Signature:
Print Name:
(Joc: I MC -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
xa
wit
44' / -r Se
•
Permit Number: M09 -019
Issue Date: 04/08/2009
Permit Expires On: 10/05/2009
U - Date: 04 1 01 1 1)
ed t . permit and know the same to be true and correct. All provisions of law and ordinances
, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or th rformance of work. am authorized to sign and obtain this mechanical permit.
Date: `6 4 C r
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
M09 -019 Printed: 04 -08 -2009
Parcel No.:
Address:
Suite No:
Tenant:
7220 SW 43 ST TUKW
NC POWER SYSTEMS
1: ** *BUILDING DEPARTMENT CONDITIONS * **
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Permit Number: M09 -019
Status: ISSUED
Applied Date: 03/03/2009
Issue Date: 04/08/2009
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Manufacturers installation instructions shall be available on the job site at the time of inspection.
7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: Cond -10/06
* *continued on next page **
M09 -019 Printed: 04 -08 -2009
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
•
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature:
Print Name:
doc: Cond -10/06 M09 -019
Date:
(-7/3-/o
ordinances governing
or local laws regulating
Printed: 04 -08 -2009
Name: AN-0 r\A" -'S
Mailing Address: - 7 - 1 1 1�.. e he ± 7 i/ e S
E -Mail Address:
GENERAL CONTRACTOR INFORMATION -
(Contractor Infermation for Mechanical (pg 4) for numbing and G
Company Name:
Mailing Address:
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.ci.tukwila.wa.us
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print**
Contact Person:
E -Mail Address:
Contractor Registration Number:
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of R eco
ENGINEER OF- RECORD - All plans mustb
QNApplicationatponna.Applications Un Line\3-2008 - Permit Appl ication.doc
Rcviscd: 4 -2006
bh
amped i
Bui lding Permit N o.
Mechanic Pe rmit °N
Plumbing/Gas Perm N o.
Public Works Permit N o.
Project
(For ogee us only)
King Co Assessor's Tax No.: io Z 3 O` 0 5
Site Address:) Z 2 —O S (. ) L.( 3' ° S + -
Tenant Name: N C. P IOu. e r S a't S'
Property Owners Name: -a o.. r ,' i S k C r o u tl /t
Mailing Address: ) 7 O 3 C W. U 6 1Q-A 4L) 11, i kLa fl k) A 0 S j
1 City State Zip
Suite Number:
New Tenant:
Floor: f
❑ Yes .No
Piping (pg
Day Telephone: .� - 744 ' y 18
City State Zip
Fax N '� �e �(' ~ )
city
Day Telephone:
Fax Number:
tion Date:
State Zip
City
Day Telephone:
Fax Number:
Stare
State
Zip
neer of Record
City
Day Telephone:
x Number:
Zip
Page 1 of 6
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace<100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP/1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Water Heater
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
Incinerator - Domestic
Emergency
Generator
Air Handling Unit
<10,000 CFM
Incinerator — Comm/Ind
Other Mechanical
Equipment
I
k„-2_ P
MECHANICAL PERMIT INFORMATION - 206 - 431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name: IM C1 C. D O Y� G 1 � yv \\ Q,
Mailing Address: 1'1 1\ - ND eke A v P. S w
Contact Person: (V\ Dti1 t_
E -Mail Address:
Contractor Registration Number: W\ 4C,7 0lr 5 9 $O g..V
Valuation of Project (contractor's bid price): $ b, 600
Scope of Work (please provide detailed information): A ct(S% ( c*Je ,
(2.7p\ t0 - fe. W t Co v\ . o Ls
( I - 4e.a.► - pi...✓ne -Pok(N Co; L
Use: Residential: New .... ❑ Replacement .... ❑
Commercial: New .... ❑ Replacement
Fuel Type: Electric....]' Gas ....0 Other:
Indicate type of mechanical work being installed and the quantity below:
Q:}Applieations\Fomu- Applications On Linet3-2006 - Permit Application.doc
Revised: 4-2006
bh
City State Zip
Day Telephon( 2-64. (e ct< V'
Fax Number:
Expiration Date: 31 -- d
Page 4 of 6
BUILDING
Signature:
Date Application Accepted:
PERMIT APPLICATION NOTES — Applicable to all permits in this application`
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Print Name: A LZ. -. A
Mailing Address: - 1 r l l `1 .A-Ir-ci 1t A1,1/44 Wt S 1.
QaApplications \Ponns- Applications On LincU -2006 - Permit Applie timt.doe
Revised: 4-2006
bh
ORIZED T.
Date Application Expires:
Date: 3 - 3 ' oc)
Day Telephone( Z - b L )
City
01 [ 1 oc)
State Zip
Staff Initials:
Page 6 of 6
COMMENTS:
``
/`.j,�\
1�� : t1lk , .4 of e J d
a- ALA T A -T J4
It\ ru
,es P-t , ( c-- x—
l P -
it
Cllr.
p.m.
AT )1 Mb 'iLi)(
6U-e.}-
C
if
----1
_ R t
Project: � oed - 2
,,t
v .e; / f-
Typ of Inspection:
//�3 � al l'IG
Address: y�s"7�
Date Called: ; k /NI i it
Special Instructions:
Date Wanted% `/_ d 9
1 1 1 7 `]
Cllr.
p.m.
Requester:
Phone No:
4 w /
r2L
PERMIT l T NO.
INSPECTION RECORD
Retain a copy with permit /," y� eq�
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes. Corrections required prior to approval.
Inspect r:
Dater - (h
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100 /Call to schedule reinspection.
Receipt No.:
Date:
NC POWER - ADD MITSUBISHI UNIT W/3 HP
co C
A ft:- TWINE
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 10 2009
City of Tukwila
BUILDING DIVISION
Location
Building owner
Program user
Company
Comments
By
Dataset name
Calculation time
TRACE® 700 version
Location
Latitude
Longitude
Time Zone
Elevation
Barometric pressure
Air density
Air specific heat
Density- specific heat product
Latent heat factor
Enthalpy factor
Summer design dry bulb
Summer design wet bulb
Winter design dry bulb
Summer clearness number
Winter clearness number
Summer ground reflectance
Winter ground reflectance
Carbon Dioxide Level
Design simulation period
Cooling load methodology
Heating load methodology
7220 SW 43RD ST, TUKWILA, WA 98188
MONTEZ
MacDonald - Miller
C:1CDSITRACE7001ProjectslNC POWER K WILDER JOB.trc
11:30 AM on 03/02/2009
6.1.2
Seattle, Washington
deg
deg
47.0
122.0
8
386
29.5
0.0749
0.2444
1.0988
4,836.9
4.4953
80
64
26
0.95
0.95
0.20
0.20
400
ft
in. Hg
lb/cu ft
Btu/lb-°F
Btu /h•cfm• °F
Btu•min /h•cu ft
Ib•min /hr•cu ft
°F
°F
°F
ppm
January - December
TETD -TA1
UATD
CIT ait A
MAR 0 3 2009
PERMIT CENTER
TRACE oo
cornpreherolve building analysts
�..,. �
. Vane
COOLING COIL PEAK
Peaked at Time: Mo /Hr: 9 / 13
Outside Air: OADB/WB /HR: 74 / 61 /
61
CLG SPACE PEAK
Mo /Hr: Sum of
OADB: Peaks
HEATING COIL PEAK
Mo /Hr: Heating Design
OADB: 26
TEMPERATURES
Cooling Heating
SADB 55.0 90.0
Plenum 72.6 67.2
Space
Plenum
Net Percent
Space Percent
Space Peak
Coil Peak Percent
Return
72.5
67.2
Sens. + Lat.
Sens. + Lat
Total Of Total
Sensible Of Total
Space Sens
Tot Sens Of Total
Ret/OA
72.5
67.2
Btu /h
Btu /h
Btu /h
( %)
Btu /h
( %)
Btu /h
Btu /h
( %)
Fn MtrTD
0.0
0.0
Envelope Loads
Envelope Loads
Fn BldTD
0.0
0.0
Skylite Solar
0
0
0
0
0
0
Skylite Solar
0
0
0.00
Fn Frict
0.0
0.0
Skylite Cond
0
0
0
0
0
0
Skylite Cond
0
0
0.00
Roof Cond
0
303
303
2
0
0
Roof Cond
0
-511
2.98
Glass Solar
4,503
0
4,503
31
4,503
35
Glass Solar
0
0
0.00
Glass Cond
23
0
23
0
23
0
Glass Cond
-637
-637
3.71
Wall Cond
359
88
447
3
402
3
Wall Cond
-1,335
-1,678
9.78
AIRFLOWS
Partition
0
0
0
0
0
Partition
0
0
0.00
Cooling
Heating
Exposed Floor
0
0
0
0
0
Exposed Floor
0
0
0.00
Vent
0
0
Infiltration
501
501
3
303
2
Infiltration
-3,360
-3,360
19.59
Infil
73
73
Sub Total = =>
5,385
390
5,776
40
5,230
41
Sub Total =_>
-5,331
-6,185
36.07
Supply
683
683
MinStop/Rh
0
0
Internal Loads
Internal Loads
Return
756
756
Lights
2,236
0
2,236
15
2,236
18
Lights
0
0
0.00
Exhaust
73
73
People
3,150
3,150
22
1,750
14
People
0
0
0.00
Rm Exh
0
0
Misc
3,432
0
3,432
24
3,432
27
Misc
0
0
0.00
Auxiliary
0
0
Sub Total =_>
8,818
0
8,818
61
7,418
58
Sub Total = =>
0
0
0.00
Ceiling Load
Ventilation Load
100
0
-100
0
0
0
0
0
110
0
1
0
Ceiling Load
Ventilation Load
-147
0
0
0
0.00
0.00
ENGINEERING CKS
Adj Air Trans Heat
0
0
0
0
0
Adj Air Trans Heat
0
0
0
Cooling
Heating
Dehumid. Ov Sizing
0
0
Ov /Undr Sizing
- 11,031
- 11,031
64.33
% OA
0.0
0.0
Ov /Undr Sizing
0
0
0
0
0
Exhaust Heat
68
-0.40
Exhaust Heat
-46
-46
0
OA Preheat Diff.
0
0.00
cfm /ft
1.25
1.25
Sup. Fan Heat
0
0
RA Preheat Diff.
0
0.00
cfm /ton
563.34
Ret. Fan Heat
0
0
0
Additional Reheat
0
0.00
Duct Heat Pkup
0
0
0
ft /ton
450.38
Reheat at Design
0
0
Btu /hrft
26.64
-31.41
Grand Total =_>
14,303
244
14,548
100.00
12,757
100.00
Grand Total =_>
- 16,509
- 17,148
100.00
No. People
7
System - 001
Project Name: NC POWER - ADD MITSUBISHI UNIT W/3 HP
Dataset Name: C: \CDS \TRACE700\Projects \NC POWER K WILDER JOB.trc
System Checksums
Incremental Heat Pump
COOLING COIL SELECTION
Total Capacity Sens Cap. Coil Airflow Enter DB/WB /HR Leave DB/WB/HR
ton MBh MBh cfm °F °F gr /Ib °F °F gr /Ib
Main Cig 1.2 14.6 12.9 682.9 72.5 59.9 58.0 55.0 52.3 55.0
Aux Clg 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Opt Vent 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Total
1.2 14.6
AREAS
Gross Total Glass
ft ( %)
Floor 546
Part 0
ExFIr 0
Roof 280 0 0
Wall 670 24 4
HEATING COIL SELECTION
CapacityCoil Airflow Ent Lvg
MBh cfm °F °F
Main Htg -17.2 682.9 67.2 90.0
Aux Htg 0.0 0 0 0
Preheat 0.0 0 0 0
Humidif
Opt Vent
Total
0.0 0 0.0 0.0
0.0 0 0.0 0.0
-17.2
TRACE® 700 v6.1.2 calculated at 11:30 AM on 03/02/2009
Alternative - 1 System Checksums Report Page 1 of 1
FIRST FLOOR OFFICE
Envelope Loads
Skylite Solar
Skylite Cond
Roof Cond
Glass Solar
Glass Cond
Wall Cond
Partition
Exposed Floor
Infiltration
Sub Total = =>
Internal Loads
Lights
People
Misc
Sub Total = =>
Ceiling Load
Ventilation Load
Adj Air Trans Heat
Dehumid. Ov Sizing
Ov /Undr Sizing
Exhaust Heat
Sup. Fan Heat
Ret. Fan Heat
Duct Heat Pkup
Reheat at Design
Grand Total = =>
Project Name:
Dataset Name:
COOLING COIL PEAK
Peaked at Time:
Outside Air:
Space
Sens. + Lat.
Btu /h
Mo /Hr: 8 / 16
OADB/WB /HR: 78 / 63 / 64
CLG SPACE PEAK
Mo /Hr: 7 / 17
OADB: 78
Plenum Net Percent Space Percent
Sens. + Lat Total Of Total Sensible Of Total
Btu /h Btu /h ( %) Btu /h ( %)
o 0 0 0 0 0
o 0 0 0 0 0
o 0 0 0 0 0
o 0 0 0 0 0
0 0 0 0 0 0
269 64 333 7 312 7
0 0 0 0 0
0 0 0 0 0
347 347 7 237 5
617 64 681 14 549 12
1,089 0 1,089 22 1,089 25
1,350 1,350 27 750 17
1,954 0 1,954 39 1,954 44
4,393 0 4,393 87 3,793 86
70 -70 0 0 80 2
0 0 0 0 0 0
0 0 0 0 0
O 0
0 0 0 0 0
-33 -33 -1
O 0
0 0 0
0 0 0
0 0
5,081 -39 5,042 100.00 4,423 100.00
NC POWER - ADD MITSUBISHI UNIT W/3 HP
C: \CDS \TRACE700\Projects \NC POWER K WILDER JOB.trc
Room Checksums
By MacDonald - Miller
Space Peak Coil Peak Percent
Space Sens Tot Sens Of Total
Btu /h Btu /h ( %)
Envelope Loads
Skylite Solar 0
Skylite Cond 0
Roof Cond 0
Glass Solar 0
Glass Cond 0
Wall Cond -663
Partition 0
Exposed Floor 0
Infiltration -1,637
Sub Total =_> -2,300
Internal Loads
Lights 0
People 0
Misc 0
Sub Total = => 0
Ceiling Load -72
Ventilation Load 0
Adj Air Trans Heat 0
Ov /Undr Sizing -3,352
Exhaust Heat
OA Preheat Diff.
RA Preheat Diff.
Additional Reheat
System Plenum Heat
Grand Total = =>
Total Capacity
ton MBh
Main Clg 0.4 5.0
Aux Clg 0.0 0.0
Opt Vent 0.0 0.0
Total 0.4 5.0
COOLING COIL SELECTION
Sens Cap. Coil Airflow Enter DB/WB /HR
MBh cfm °F °F gr/lb
4.3
0.0
0.0
237 72.8
0 0.0
0 0.0
60.2 59.0
0.0 0.0
0.0 0.0
Leave DB/WB/HR
°F °F gr/lb
55.0 52.7 56.5
0.0 0.0 0.0
0.0 0.0 0.0
HEATING COIL PEAK
Mo /Hr: Heating Design
OADB: 26
-5,723
Floor
Part
ExFIr
Roof
Wall
AREAS
Gross Total Glass
fi (%)
266
0
0
0 0 0
330 0 0
0 0
0 0
0 0
0 0
0 0
-825 14
0 0
0 0
-1,637 28
-2,462 41
0 0
0 0
0 0
O 0
O 0
0 0
0 0
-3,352 56
33 -1
0 0
0 0
0 0
-164 3
-5,945 100.00
TEMPERATURES
Cooling Heating
SADB 55.0 90.0
Plenum 72.8 67.2
Return 72.8 67.2
Ret/OA 72.8 67.2
Fn MtrTD 0.0 0.0
Fn BIdTD 0.0 0.0
Fn Frict 0.0 0.0
Vent
Infil
Supply
MinStop/Rh
Return
Exhaust
Rm Exh
Auxil
AIRFLOWS
Cooling Heating
0 0
35 35
237 237
0 0
272 272
35 35
0 0
0
0
ENGINEERING CKS
Cooling Heating
% OA 0.0 0.0
cfm /ft
cfm /ton
0.89 0.89
ft /ton 633.13
Btu /hr.ft 18.95 -22.35
No. People
563.51
3
HEATING COIL SELECTION
Capacity Coil Airflow Ent Lvg
MBh cfm °F °F
Main Htg -5.9 237 67.2 90.0
Aux Htg 0.0 0 0.0 0.0
Preheat 0.0 0 0.0 0.0
Humidif 0.0 0 0.0 0.0
Opt Vent 0.0 0 0.0 0.0
Total -5.9
TRACE® 700 v6.1.2 calculated at 11:30 AM on 03/02/2009
Alternative - 1 Room Checksums report Page 1 of 3
• Room Checksums
SECOND FLOOR OFFICE EAST
By MacDonald - Miller
Envelope Loads
Skylite Solar
Skylite Cond
Roof Cond
Glass Solar
Glass Cond
Wall Cond
Partition
Exposed Floor
Infiltration
Sub Total = =>
Internal Loads
Lights
People
Misc
Sub Total = =>
Grand Total = =>
COOLING COIL PEAK
Peaked at Time:
Outside Air:
Ceiling Load
Ventilation Load
Adj Air Trans Heat
Dehumid. Ov Sizing
Ov /Undr Sizing
Exhaust Heat
Sup. Fan Heat
Ret. Fan Heat
Duct Heat Pkup
Reheat at Design
Space
Sens. + Lat.
Btu /h
Mo /Hr: 9 / 13
OADB/WB /HR: 74 / 61 / 61
Plenum Net
Sens. + Lat Total
Btu /h Btu /h
0 0 0
0 0 0
0 151 151
2,251 0 2,251
11 0 11
37 10 47
0 0
0 0
76 76
2,376 162 2,538
573 0 573
900 900
739 0 739
2,212 0 2,212
15 -15 0
0 0 0
0 0
0
0 0
-7 -7
0
0 0
4,603 140
0 0
0
Percent
Of Total
( % )
4,744 100.0
0
0
3
47
0
1
0
0
2
54
12
19
16
47
0
0
0
CLG SPACE PEAK
Mo /Hr: 9 / 13
OADB: 74
Space Percent
Sensible Of Total
Btu /h ( %)
0 0
0 0
0 0
2,251 54
11 0
37 1
0 0
0 0
33 1
2,332 56
573 14
500 12
739 18
1,812 44
15 0
0 0
0 0
0 0
4,159 100.00
Envelope Loads
Skylite Solar
Skylite Cond
Roof Cond
Glass Solar
Glass Cond
Wall Cond
Partition
Exposed Floor
Infiltration
Sub Total = =>
Internal Loads
Lights
People
Misc
Sub Total = =>
Ceiling Load
Ventilation Load
Adj Air Trans Heat
Ov /Undr Sizing
Exhaust Heat
OA Preheat Diff.
RA Preheat Diff.
Additional Reheat
System Plenum Heat
Grand Total = =>
HEATING COIL PEAK
Mo /Hr: Heating Design
OADB: 26
Space Peak
Space Sens
Btu /h
0
0
0
0
-318
-184
0
0
-861
-1,364
0
0
0
0
-38
0
0
-3,981
-5,383
Coil Peak Percent
Tot Sens Of Total
Btu /h ( %)
0 0
0 0
-256 5
O 0
- 318 6
-237 4
0 0
0 0
- 861 15
-1,673 30
0 0
0 0
0 0
0 0
0 0
O 0
0 0
-3,981 71
17 0
O 0
0 0
0 0
45 -1
-5,591 100.00
Total Capacity
ton MBh
Main CIg 0.4 4.7
Aux Clg 0.0 0.0
Opt Vent 0.0 0.0
Total 0.4 4.7
COOLING COIL SELECTION
Sens Cap. Coil Airflow Enter DB/WB/HR
MBh cfm °F °F gr/lb
4.3
0.0
0.0
223 72.3
0 0.0
0 0.0
59.7 57.5
0.0 0.0
0.0 0.0
Leave DB/WB/HR
°F °F gr/lb
55.0 52.1 54.2
0.0 0.0 0.0
0.0 0.0 0.0
Project Name: NC POWER - ADD MITSUBISHI UNIT W/3 HP
Dataset Name: C: \CDS \TRACE700 \Projects \NC POWER K WILDER JOB.trc
Floor
Part
ExFIr
Roof
Wall
AREAS
Gross Total Glass
140
0
0
140
100
ft ( %)
0 0
12 12
TEMPERATURES
Cooling Heating
SADB 55.0 90.0
Plenum 72.3 67.2
Return 72.3 67.2
Ret/OA 72.3 67.2
Fn MtrTD 0.0 0.0
Fn BIdTD 0.0 0.0
Fn Frict 0.0 0.0
Vent
Infil
Supply
MinStop/Rh
Return
Exhaust
Rm Exh
Auxil
AIRFLOWS
Cooling
0
19
223
0
241
19
0
0
Heating
0
19
223
0
241
19
0
0
% OA
cfm /ft
cfm /ton
ENGINEERING CKS
ft /ton 354.17
Btu/hr-ft 33.88
No. People
Cooling Heating
0.0 0.0
1.59 1.59
563.29
2
-39.94
HEATING COIL SELECTION
Capacity Coil Airflow Ent
MBh cfm °F
Main Htg
Aux Htg
Preheat
Humidif
Opt Vent
Total
-5.6
0.0
Lvg
°F
223 67.2 90.0
0 0.0 0.0
0.0 0 0.0 0.0
0.0 0 0.0 0.0
0.0 0 0.0 0.0
-5.6
TRACE® 700 v6.1.2 calculated at 11:30 AM on 03/02/2009
Alternative - 1 Room Checksums report Page 2 of 3
SECOND FLOOR OFFICE WEST
Room Checksums
By MacDonald - Miller
Envelope Loads
Skylite Solar
Skylite Cond
Roof Cond
Glass Solar
Glass Cond
Wall Cond
Partition
Exposed Floor
Infiltration
Sub Total = =>
Internal Loads
Lights
People
Misc
Sub Total = =>
Ceiling Load
Ventilation Load
Adj Air Trans Heat
Dehumid. Ov Sizing
Ov /Undr Sizing
Exhaust Heat
Sup. Fan Heat
Ret. Fan Heat
Duct Heat Pkup
Reheat at Design
Grand Total =_>
COOLING COIL PEAK
Peaked at Time: Mo /Hr: 9 / 13
Outside Air: OADB/WB /HR: 74 / 61 / 61
Space
Sens. + Lat.
Btu /h
Plenum Net Percent
Sens. + Lat Total Of Total
Btu /h Btu /h ( %)
0 0 0 0
0 0 0 0
0 151 151 3
2,251 0 2,251 47
11 0 11 0
53 13 66 1
0 0 0
0 0 0
77 77 2
2,392 165 2,557 54
573 0 573 12
900 900 19
739 0 739 16
2,212 0 2,212 46
15 -15 0 0
0 0 0 0
0 0 0
0 0
0 0 0
-7 -7 0
0 0
0 0 0
0 0 0
0 0
4,619 143 4,762 100.00
CLG SPACE PEAK
Mo /Hr: 9 / 13
OADB: 74
Space Percent
Sensible Of Total
Btu /h ( %)
0 0
0 0
0 0
2,251 54
11 0
53 1
0 0
0 0
33 1
2,348 56
573
500
739
1,812
15
0
0
14
12
18
43
0
0
0
0 0
4,175 100.00
Internal Loads
Lights 0
People 0
Misc 0
Sub Total = => 0
Ceiling Load -38
Ventilation Load 0
Adj Air Trans Heat 0
Ov /Undr Sizing -3,698
Exhaust Heat
OA Preheat Diff.
RA Preheat Diff.
Additional Reheat
System Plenum Heat
Grand Total = =>
HEATING COIL PEAK
Mo /Hr: Heating Design
OADB: 26
Space Peak Coil Peak Percent
Space Sens Tot Sens Of Total
Btu /h Btu /h ( %)
Envelope Loads
Skylite Solar 0
Skylite Cond 0
Roof Cond 0
Glass Solar 0
Glass Cond -318
Wall Cond -488
Partition 0
Exposed Floor 0
Infiltration -861
Sub Total =_> -1,667
-5,403
0 0
0 0
-256 5
0 0
-318 6
-615 11
0 0
0 0
-861 15
-2,050 37
0 0
0 0
0 0
0 0
0 0
0 0
0 0
-3,698 66
17 0
0 0
0 0
0 0
119 -2
-5,612 100.00
Main Clg
Aux Clg
Opt Vent
Total
COOLING COIL SELECTION
Total Capacity Sens Cap. Coil Airflow Enter DB/WB /HR
ton MBh MBh cfm
0.4 4.8
0.0 0.0
0.0 0.0
0.4 4.8
4.3
0.0
0.0
224 72.3
0 0.0
0 0.0
°F °F gr/lb
59.7 57.5
0.0 0.0
0.0 0.0
Leave DB/WB/HR
°F °F gr/lb
55.0 52.1 54.2
0.0 0.0 0.0
0.0 0.0 0.0
Project Name:
Dataset Name:
NC POWER - ADD MITSUBISHI UNIT W/3 HP
C:\CDS \TRACE700 \Projects\NC POWER K WILDER JOB.trc
Floor
Part
ExFIr
Roof
Wall
AREAS
Gross Total Glass
ft ( %)
140
0
0
140 0 0
240 12 5
TEMPERATURES
Cooling Heating
SADB 55.0 90.0
Plenum 72.3 67.2
Return 72.3 67.2
Ret/OA 72.3 67.2
Fn MtrTD 0.0 0.0
Fn BIdTD 0.0 0.0
Fn Frict 0.0 0.0
Vent
Infil
Supply
MinStop /Rh
Return
Exhaust
Rm Exh
Auxil
AIRFLOWS
Cooling Heating
0 0
19 19
224 224
0 0
242 242
19 19
0 0
0
0
ENGINEERING CKS
Cooling Heating
% OA 0.0 0.0
cfm /ft 1.60 1.60
cfm /ton 563.21
ft /ton 352.76
Btu/hr-ft 34.02 -40.09
No. People
2
HEATING COIL SELECTION
Capacity Coil Airflow Ent Lvg
MBh cfm °F °F
Main Htg -5.6 224 67.2 90.0
Aux Htg 0.0 0 0.0 0.0
Preheat 0.0 0 0.0 0.0
Humidif 0.0 0 0.0 0.0
Opt Vent 0.0 0 0.0 0.0
Total -5.6
TRACE® 700 v6.1.2 calculated at 11:30 AM on 03/02/2009
Alternative - 1 Room Checksums report Page 3 of 3
ACTIVITY NUMBER: M09 -019 DATE: 03 -03 -09
PROJECT NAME: NC POWER SYSTEMS
SITE ADDRESS: 7220 SW 43 ST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Issued
/ DE � PARTME�NT �+_�r „
PUTding Di IO'�
Public Works
DETERMINATIO OF COMPLETENESS: (Tues., Thurs.)
Complete U
Comments:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28-02
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
5l I•c oil
Fire Prevention
Structural
Incomplete U
❑ Permit Coordinator ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
DUE DATE: 03-5-09
TUES /THURS R TING:
Please Route Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS:
DATE:
DATE:
Planning Division
Not Applicable
Not Approved (attach comments) ❑
DUE DATE: 04-02-09
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
DIVCOI *988RC
DIVCO
INCORPORATION
CONSTRUCTION
CONTRACTOR
GENERAL
UNUSED
12/3/2002
11/7/2010
ACTIVE
MACDOMR026RU
MACDONALD
MILLER RSDNTL
INC
CONSTRUCTION
CONTRACTOR
UNUSED
GENERAL
12/31/1998
12/31 /2001
ARCHIVED
MACDOMR076OPMILLER
MACDONALD
RESIDENTIAL
CONSTRUCTION
CONTRACTOR
GENERAL
UNUSED
9/17/1993
12/30/1998
ARCHIVED
DIVCOEC188LC
DIVCO ENERGY
CONTROL
COMPANY
CONSTRUCTION
CONTRACTOR
GENERAL
UNUSED
6/3/1982
5/26/1997
ARCHIVED
MACDOM *248J9
MACDONALD
MILLER CO
CONSTRUCTION
CONTRACTOR
GENERAL
UNUSED
4/29/1976
2/1/2002
ARCHIVED
ENCOMMS984CA
ENCOMPASS
MECHANICAL
SERVICES
CONSTRUCTION
CONTRACTOR
GENERAL
UNUSED
2/1/2002
2/1/2004
EXPIRED
LINFOAR980QG
LINFORD AIR 8
REFRIGERTN INC
CONSTRUCTION
CONTRACTOR
GENERAL
UNUSED
11/7/2002
11/7/2004
INACTIVE
DIVCOI*031L4
DIVCO INC
CONSTRUCTION
CONTRACTOR
GENERAL
UNUSED
6/24/1997
8/1/2003
REREGISTERED
Untitled Page
Other Associated Licenses
Business Owner Information
•
https://fortress.wa.gov/lni/bbip/Detail.aspx
0
General /Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work
within the scope of its specialty. A General or Specialty construction Contractor must
maintain a surety bond or assignment of account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent
Company
MACDONALD /MILLER FAC SOL
INC
2067684180
PO BOX 47983
SEATTLE
WA
98106
KING
Corporation
UBI No.
Status
License No.
License Type
Effective
Date
Expiration
Date
Suspend Date
Specialty 1
Specialty 2
602254260
ACTIVE
MACDOFS980RU
CONSTRUCTION
CONTRACTOR
12/31/2002
12/31/2010
GENERAL
UNUSED
Page 1 of 2
Name
Role
Effective Date I Expiration Date
04/08/2009
ExislingQpontoragg
Area_20
•
tie
iiIii
•:.
iii ::•.::
::::: •r::
:::'::
::::::
IV
. •
0 •
• "
if 11
...
11. •
iiiiii::::::::::::*33:::::.0 : : : : :** : : : : : : : : : :*: : ::: : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 1 : : : : : : : : : : : : : : : : : : : : : : : 8 : : : : : : : : NWom.:40:::::::::::: 4 :::::: . x:x:::::::4::::::::::::::::::::::::::::::::::::::::::::::i:i:m4:om:v.::4•::4:::::::::::::::iit
•
. • •
: $4 1.
:..;.
:2:4':':***:•:**:':':*:*50c*:440:44*.x.:*:*:•:"'xy.44•••••••:•:•:*.w.•••:•:4444•••••:•:•:•:•:•:•:•:•:"0:4444*:4•NIteN.:*:•:o.:44.:44.:440:444.:.:-:-xo:0•••••mo:44:0:444.:.:•:.:•:.:44410:.:.:-:•:ox.:.:.:.:.x.x.:.:.:ox.x.:4:•:.:::::::::::::::::;:x:::::4::•.::.:::::::.0::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::00.:000;:::::::::::::::::::::::0:::::::::::X:::::::::::::::::::::::::::::::::::::::::::::::::03X:X:M0KOM:MSMO
....
M.:
.:.: ....
:44
:.:.
....
g
....
:.:.:
:;:::
V.:
::
o:
i
...
A,.
oo
:0
....
e:
iiii•
Existing Opel) Roof
i
4
.X.
• •
::;•,,; i :
• •
i i i
4
gi
• •
i
.
• • 4
• •
• • i
gi
;Z.
41
.. 0 . .:.
• • . •
.X
• •
4 I •
• • •
• • 4
• f •
• II •
• •
• • •
4 • •
Ii
• •
-• •
Existingpen Roof
••
•• •
4 • •
• • •
• 9 •
:
• •
• • •
• • •
• • •
K
iiiii • •
• •
• • •
• •
• • •
• •
• • •
• •
• •
...K
1K
. K .
. 4 .
K
2
Z
*:i
A
. 2: .
AN
i :4*.X".:"M""...*".. r ."M"..A"""""*".""*""."*". 7 . " . " :1 * * * * * ***** * * * * * * * * * . *
!
AN
K.:
....."
:
:::
•::::
...:.:i
',•••:
Jippiqr VVIk:Way'
..:.•:-::::: ..::.,::::.::•:::.:•::-.:'
. ..::.::....::-:::::.:•:::::::.:.:.:..::.
• '
• :: :::::::::::
,
:;:i
:E?
.1::
:•••
:::
:::
.gi
::....
:i:
iii:1 74-4)1
:::
:::. ,------1
I....._
I
i
—.`?■-
-,........_--
sr)
_., 4 r 3.:
z)
o:
X -
!
*„.
..:
0 ..,
'..
''—','
1
,„
. : O U P . 2 0 2 . ' I I i Il ii.... C'. ) N N . \ \ - \
r
, ___ 7 (_.3_ - )_„1:.
t ,
I:
:::
: §1
F ------ -----1- ------ -
A
\
4
4
,
.....
:•:-:
Pk.
:O.
• • •
• .
• • .
....
1 2.)---- ;I:
--------------_._______------''' t'
5 X ling ,Dffic
Are,a ?Qi
HP-2))
_Existing Offic@
Area 202
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 1 0 2009
City of Tukwila
BUILDING DIVISioni
MO 0 I
RECEIVED
CITY OF TUKVOLA
MAR 0 3 2009
PERMIT CENTER
ENGINEER:
0)
CHECKED
B. GEZ01
CAD:
J. V1ONTEZ
DRAWING NUMBER:
— 'I 5 6 8 7396097
SHEET NUMBER:
bi
Cl
(.6
0
LU
1 CY:
w
z
I
I I
0
0
CO
z
0
0
.14
0
0
„,.
CO
CO
LL
MAnniVi
LAST REVISED:
DATE PLOTTED:
3/3/09
iSSIJE DATE:
3/3/09
TM2.02
lairiPITAKZUMIRMEg
‘,!;;•••
' *s.';Z•:
0 1
lark6v;;;;;Kf;:eat
Women s
Open Storage
Area 106
t"
_AiAafawwwnrvvr ANON&
lifm)§~N£
•
. 1,20,04S
• ..a
whiawmalwaffirMEMERIMENEMBINIAINIE
A441
Alsomassi-
Open Storage_
Area 103
ElELP F-tr.Nre
f VIP C/
Outdoor Unit AC Sleg•f2
ZAREIMPISIffiff.'&::-.
tiggiggAkk.w.. .
V5A
ARWU4komismT
Office
Area 103
IMF- co
A WA I T.:6Q A. ) ,
- Peif.WVAN:
.7- ---------
Mgrazzim.,:aalliMPNAPI allogie afitira4:42: SIMINSIEVESEEL L wkozetax
011,6
'12 Roll Up Door
Opep Shop Area 191
12' Roll Up Door
Vaniandletkpii:
))*
MM.1.02)W.W.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 1 0 2009
City of Tukwila
BUILDING DIVISION
11 0 qq) ct
RECEIVED
crry OF TUKVVILA
MAR 03 2009
PERMIT CENTER
1 1 1 1 1 1 1 I
1 1 1 1 1 1 1 1
I I I I I I 1 I
1 1 1 1 1 1 1 1
(/)
w
0
0
0_ Ct
D c ' c i )
LLI ci)
0 0
U. 0 w
OZEIP_
ENGINEER:
CHECKED B Y
B. GEZON
CAD:
J. MONTEZ
DRAWING NUMBER:
C-1568-7396097
SHEET NUMBER:
TM2.01
Ui
LAST REVISED:
DATE PLOTTED:
3/3/09
ISSUE DATE:
3/3/09
z
0
0
F-
co
z
0
0
ct
0
LL
0
w
(/)
CONTACT LIST
TITLE
PROJECT ENGINEER
ACCOUNT MANAGER
FIELD FOREMAN
REFRIGERATION FOREMAN
OWNER REP.
NAME
JESSE MONTEZ
KEVIN WILDER
DARYL ANDERSON
DEAN GRASSER
JOHN STORM
COMPANY
MACDONALD MILLER
MACDONALD MILLER
MACDONALD MILLER
MACDONALD MILLER
HARNISH GROUP
PHONE NUMBER
206 -768 -4288
253- 680 -3168
206 - 768 -4216
206 -768 -4270
206- 849 -7191
FAX NUMBER
206 - 768 -4289
206- 768 -4217
206- 768 -4271
SCOPE OF WORK
ADD MITSUBISHI TRIPLE DUCTLESS SPLIT SYSTEM WITH WIRELESS REMOTE CONTROLS.
LEGAL DESCRIPTION
APN # 3623049059
LEGAL ADDRESS: 7220 SW 43RD ST, TUKWILA, WA. 98055
LEGAL DESCRIPTION :TUUKWILA LOT CONSOLIDATION L07 -087 REC 2008047001690 DAF -POR OF NE 1/4 OF NW 1/4 OF 36 -23 -04 DAF -BAAP 669.75 FT W & 30 FT N OF NE COR OF HENRY
DC #43 TH WLY 66 FT ALG A LN PARALLEL. TO & 30 FT N OF N LN OF SD DC TH N 1 -39 E 120 FT'TH S 88 -21 E TO W LN OF R/R R/W TN S ALG SO W LN TAP ON A LN 30 FT N &
PARALLEL TO N LN OF SD DC TH WLY ALG PARALLEL LN 'I'O POB
ELECTRICAL
VOLT /PH MCA,
MODEL
MXZ- 3A3ONA
208 -230/1
NOM.
TONS
INDOOR UNIT
MODEL
MSZ -Al2NA
MSZ -AO9NA
DUCTLESS SPLIT SYSTEM HEAT PUMP SCHEDULE
HSPF/
SEER
10/16
10/16
208 -230/1
208 -230/1
VOLT /PH
UNIT
NO,
DI
DHP -201
MANUFACTURER
MITSUBISHI
MITSUBISHI
MITSUBISHI
S RECOMMENDATIONS:
NOTES
NEW ,1-7
DHP -202
NOTES
7 OU UNIT DISCONNECT AND POWER WIRING ;SO WALL UNI I S €3Y EL ECTRICAL CONTRACTOR...
2 INSTALL T HREE WALL UNITS AND OU TDOQR CONDEN IN. ACCORDAN ,WITH MANUFACTU
3 PROVID 3/4' TYPE L COPPER CONDEN DR
4 INDOOR UNITS FAC
Y R AN Cl
D CIR11T P RO T ECT E D FOR S OIN
I NGLE PT ELECT CONN IO
5 PROVIDE WIRELESS CONTROL WHITE FINISH CONDENSATE PUMP FOR EAC,A,WALL UN
6 SINGLE OUTDOOOR "CONDENSING UNIT S ERVES DHP 101 201 AND .
7 WITH'R41C).REFRIGERANT.
SEPARATE PERMIT
REQUIRED FOR:
p Mechanical
al Electrical
hl Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
a
HVAC GENERAL NOTES
1. THE HVAC SYSTEM FOR THIS PROJECT IS BASED ON THE FOLLOWING CRITERIA:
ROOF °U" VALUE (BTUH /S.F. °F) = 0,044
WALL "U" VALUE (BTUH /S.F. °F) = 0.0645
FLOOR "U" VALUE (BTUH /S.F. °F) = N/A
GLASS "U" VALUE (BTUH /S.F. °F) = 0.88
GLASS SHADE COEFF. = 0.60
LIGHTING (WATTS /S.F.) = 1.2
MISC. EQUIP. (WATTS /S.F,) = 0.5
PEOPLE DENSITY (S.F. /PERSON) = N/A
COOLING INDOOR DESIGN TEMP ( = 72
COOLING OUTDOOR DESIGN TEMP ( "F) = 80
HEATING INDOOR DESIGN TEMP ( °F) = 68
HEATING OUTDOOR DESIGN TEMP (°F ) = 26
2. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE
WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK.
3. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL
BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES.
4. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2006 IBC.
5. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN TI lE INTEGRITY
AND RATING OF THE FLOOR OR WALL.
6. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED
ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR.
7. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER.
RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF
DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES.
8. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE
SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM.
9. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEER NC -2.1 FUNDAMENTAL
BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING.
10.A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER.
11, OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412,4.1, EXCEPT
AS ALLOWED BY WSEC.
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
c:n' may include additional plan review fees.
City Of TUkwiia
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 10 2009
v
City of (TI kwila
BUILDING DIVISION
FILE COPY
Permit Na. O
Plan review approval Is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged
BY
Date:
RECEIVED
CITY OF TUKWILA
MAR 0 3 2009
PERMIT CENTER
i
0 Ct
D
LLB
oO
LL 0
0
ENGINEER:
CHECKED BY
CAD:
J. MONTEZ
DRAWING NUMBER:
C-1568-7396097
SHEET NUMBER:
LAST REVISED:
DATE PLOTTED:
B. CEZON 3 /3/09
ISSUE DATE:
3/3/09
TMO.O1