HomeMy WebLinkAboutPermit M09-019 - NC POWER SYSTEMSNC POWER SYSTEMS 7220 SW 43 ST M09 -019 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: , doc: IMC -10/06 7220 SW 43 ST TUKW Contact Person: Name: JESSE MONTEZ Address: 7717 DETROIT AV SW , SEATTLE WA Value of Mechanical: $6,000.00 Type of Fire Protection: CitAbf Tukwila Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater .Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler 'Ventilation Fan connected to single duct 'Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us NC POWER SYSTEMS 7220 SW 43 ST , TUKWILA WA Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU MECHANICAL PERMIT DESCRIPTION OF WORK: ADDING TRIPLE DUCTLESS SPLIT SYSTEM WITH REMOTE WIRELESS CONTROLS (1 HEAT PUMP WITH 3 FAN COIL UNITS) EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** M09 -019 Permit Number: M09 -019 Issue Date: 04/08/2009 Permit Expires On: 10/05/2009 Phone: Phone: 206 768 -4288 Phone: 206 - 768 -4180 Expiration Date: 12/31/2010 Fees Collected: $242.81 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 - HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 04 -08 -2009 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Signature: Print Name: (Joc: I MC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us xa wit 44' / -r Se • Permit Number: M09 -019 Issue Date: 04/08/2009 Permit Expires On: 10/05/2009 U - Date: 04 1 01 1 1) ed t . permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th rformance of work. am authorized to sign and obtain this mechanical permit. Date: `6 4 C r This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -019 Printed: 04 -08 -2009 Parcel No.: Address: Suite No: Tenant: 7220 SW 43 ST TUKW NC POWER SYSTEMS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M09 -019 Status: ISSUED Applied Date: 03/03/2009 Issue Date: 04/08/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M09 -019 Printed: 04 -08 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: doc: Cond -10/06 M09 -019 Date: (-7/3-/o ordinances governing or local laws regulating Printed: 04 -08 -2009 Name: AN-0 r\A" -'S Mailing Address: - 7 - 1 1 1�.. e he ± 7 i/ e S E -Mail Address: GENERAL CONTRACTOR INFORMATION - (Contractor Infermation for Mechanical (pg 4) for numbing and G Company Name: Mailing Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print** Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of R eco ENGINEER OF- RECORD - All plans mustb QNApplicationatponna.Applications Un Line\3-2008 - Permit Appl ication.doc Rcviscd: 4 -2006 bh amped i Bui lding Permit N o. Mechanic Pe rmit °N Plumbing/Gas Perm N o. Public Works Permit N o. Project (For ogee us only) King Co Assessor's Tax No.: io Z 3 O` 0 5 Site Address:) Z 2 —O S (. ) L.( 3' ° S + - Tenant Name: N C. P IOu. e r S a't S' Property Owners Name: -a o.. r ,' i S k C r o u tl /t Mailing Address: ) 7 O 3 C W. U 6 1Q-A 4L) 11, i kLa fl k) A 0 S j 1 City State Zip Suite Number: New Tenant: Floor: f ❑ Yes .No Piping (pg Day Telephone: .� - 744 ' y 18 City State Zip Fax N '� �e �(' ~ ) city Day Telephone: Fax Number: tion Date: State Zip City Day Telephone: Fax Number: Stare State Zip neer of Record City Day Telephone: x Number: Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP/1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment I k„-2_ P MECHANICAL PERMIT INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: IM C1 C. D O Y� G 1 � yv \\ Q, Mailing Address: 1'1 1\ - ND eke A v P. S w Contact Person: (V\ Dti1 t_ E -Mail Address: Contractor Registration Number: W\ 4C,7 0lr 5 9 $O g..V Valuation of Project (contractor's bid price): $ b, 600 Scope of Work (please provide detailed information): A ct(S% ( c*Je , (2.7p\ t0 - fe. W t Co v\ . o Ls ( I - 4e.a.► - pi...✓ne -Pok(N Co; L Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement Fuel Type: Electric....]' Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Q:}Applieations\Fomu- Applications On Linet3-2006 - Permit Application.doc Revised: 4-2006 bh City State Zip Day Telephon( 2-64. (e ct< V' Fax Number: Expiration Date: 31 -- d Page 4 of 6 BUILDING Signature: Date Application Accepted: PERMIT APPLICATION NOTES — Applicable to all permits in this application` Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: A LZ. -. A Mailing Address: - 1 r l l `1 .A-Ir-ci 1t A1,1/44 Wt S 1. QaApplications \Ponns- Applications On LincU -2006 - Permit Applie timt.doe Revised: 4-2006 bh ORIZED T. Date Application Expires: Date: 3 - 3 ' oc) Day Telephone( Z - b L ) City 01 [ 1 oc) State Zip Staff Initials: Page 6 of 6 COMMENTS: `` /`.j,�\ 1�� : t1lk , .4 of e J d a- ALA T A -T J4 It\ ru ,es P-t , ( c-- x— l P - it Cllr. p.m. AT )1 Mb 'iLi)( 6U-e.}- C if ----1 _ R t Project: � oed - 2 ,,t v .e; / f- Typ of Inspection: //�3 � al l'IG Address: y�s"7� Date Called: ; k /NI i it Special Instructions: Date Wanted% `/_ d 9 1 1 1 7 `] Cllr. p.m. Requester: Phone No: 4 w / r2L PERMIT l T NO. INSPECTION RECORD Retain a copy with permit /," y� eq� INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspect r: Dater - (h ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100 /Call to schedule reinspection. Receipt No.: Date: NC POWER - ADD MITSUBISHI UNIT W/3 HP co C A ft:- TWINE REVIEWED FOR CODE COMPLIANCE APPROVED MAR 10 2009 City of Tukwila BUILDING DIVISION Location Building owner Program user Company Comments By Dataset name Calculation time TRACE® 700 version Location Latitude Longitude Time Zone Elevation Barometric pressure Air density Air specific heat Density- specific heat product Latent heat factor Enthalpy factor Summer design dry bulb Summer design wet bulb Winter design dry bulb Summer clearness number Winter clearness number Summer ground reflectance Winter ground reflectance Carbon Dioxide Level Design simulation period Cooling load methodology Heating load methodology 7220 SW 43RD ST, TUKWILA, WA 98188 MONTEZ MacDonald - Miller C:1CDSITRACE7001ProjectslNC POWER K WILDER JOB.trc 11:30 AM on 03/02/2009 6.1.2 Seattle, Washington deg deg 47.0 122.0 8 386 29.5 0.0749 0.2444 1.0988 4,836.9 4.4953 80 64 26 0.95 0.95 0.20 0.20 400 ft in. Hg lb/cu ft Btu/lb-°F Btu /h•cfm• °F Btu•min /h•cu ft Ib•min /hr•cu ft °F °F °F ppm January - December TETD -TA1 UATD CIT ait A MAR 0 3 2009 PERMIT CENTER TRACE oo cornpreherolve building analysts �..,. � . Vane COOLING COIL PEAK Peaked at Time: Mo /Hr: 9 / 13 Outside Air: OADB/WB /HR: 74 / 61 / 61 CLG SPACE PEAK Mo /Hr: Sum of OADB: Peaks HEATING COIL PEAK Mo /Hr: Heating Design OADB: 26 TEMPERATURES Cooling Heating SADB 55.0 90.0 Plenum 72.6 67.2 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 72.5 67.2 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 72.5 67.2 Btu /h Btu /h Btu /h ( %) Btu /h ( %) Btu /h Btu /h ( %) Fn MtrTD 0.0 0.0 Envelope Loads Envelope Loads Fn BldTD 0.0 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 0.0 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 303 303 2 0 0 Roof Cond 0 -511 2.98 Glass Solar 4,503 0 4,503 31 4,503 35 Glass Solar 0 0 0.00 Glass Cond 23 0 23 0 23 0 Glass Cond -637 -637 3.71 Wall Cond 359 88 447 3 402 3 Wall Cond -1,335 -1,678 9.78 AIRFLOWS Partition 0 0 0 0 0 Partition 0 0 0.00 Cooling Heating Exposed Floor 0 0 0 0 0 Exposed Floor 0 0 0.00 Vent 0 0 Infiltration 501 501 3 303 2 Infiltration -3,360 -3,360 19.59 Infil 73 73 Sub Total = => 5,385 390 5,776 40 5,230 41 Sub Total =_> -5,331 -6,185 36.07 Supply 683 683 MinStop/Rh 0 0 Internal Loads Internal Loads Return 756 756 Lights 2,236 0 2,236 15 2,236 18 Lights 0 0 0.00 Exhaust 73 73 People 3,150 3,150 22 1,750 14 People 0 0 0.00 Rm Exh 0 0 Misc 3,432 0 3,432 24 3,432 27 Misc 0 0 0.00 Auxiliary 0 0 Sub Total =_> 8,818 0 8,818 61 7,418 58 Sub Total = => 0 0 0.00 Ceiling Load Ventilation Load 100 0 -100 0 0 0 0 0 110 0 1 0 Ceiling Load Ventilation Load -147 0 0 0 0.00 0.00 ENGINEERING CKS Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Cooling Heating Dehumid. Ov Sizing 0 0 Ov /Undr Sizing - 11,031 - 11,031 64.33 % OA 0.0 0.0 Ov /Undr Sizing 0 0 0 0 0 Exhaust Heat 68 -0.40 Exhaust Heat -46 -46 0 OA Preheat Diff. 0 0.00 cfm /ft 1.25 1.25 Sup. Fan Heat 0 0 RA Preheat Diff. 0 0.00 cfm /ton 563.34 Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 ft /ton 450.38 Reheat at Design 0 0 Btu /hrft 26.64 -31.41 Grand Total =_> 14,303 244 14,548 100.00 12,757 100.00 Grand Total =_> - 16,509 - 17,148 100.00 No. People 7 System - 001 Project Name: NC POWER - ADD MITSUBISHI UNIT W/3 HP Dataset Name: C: \CDS \TRACE700\Projects \NC POWER K WILDER JOB.trc System Checksums Incremental Heat Pump COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB /HR Leave DB/WB/HR ton MBh MBh cfm °F °F gr /Ib °F °F gr /Ib Main Cig 1.2 14.6 12.9 682.9 72.5 59.9 58.0 55.0 52.3 55.0 Aux Clg 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Total 1.2 14.6 AREAS Gross Total Glass ft ( %) Floor 546 Part 0 ExFIr 0 Roof 280 0 0 Wall 670 24 4 HEATING COIL SELECTION CapacityCoil Airflow Ent Lvg MBh cfm °F °F Main Htg -17.2 682.9 67.2 90.0 Aux Htg 0.0 0 0 0 Preheat 0.0 0 0 0 Humidif Opt Vent Total 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -17.2 TRACE® 700 v6.1.2 calculated at 11:30 AM on 03/02/2009 Alternative - 1 System Checksums Report Page 1 of 1 FIRST FLOOR OFFICE Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass Cond Wall Cond Partition Exposed Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Reheat at Design Grand Total = => Project Name: Dataset Name: COOLING COIL PEAK Peaked at Time: Outside Air: Space Sens. + Lat. Btu /h Mo /Hr: 8 / 16 OADB/WB /HR: 78 / 63 / 64 CLG SPACE PEAK Mo /Hr: 7 / 17 OADB: 78 Plenum Net Percent Space Percent Sens. + Lat Total Of Total Sensible Of Total Btu /h Btu /h ( %) Btu /h ( %) o 0 0 0 0 0 o 0 0 0 0 0 o 0 0 0 0 0 o 0 0 0 0 0 0 0 0 0 0 0 269 64 333 7 312 7 0 0 0 0 0 0 0 0 0 0 347 347 7 237 5 617 64 681 14 549 12 1,089 0 1,089 22 1,089 25 1,350 1,350 27 750 17 1,954 0 1,954 39 1,954 44 4,393 0 4,393 87 3,793 86 70 -70 0 0 80 2 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 -33 -33 -1 O 0 0 0 0 0 0 0 0 0 5,081 -39 5,042 100.00 4,423 100.00 NC POWER - ADD MITSUBISHI UNIT W/3 HP C: \CDS \TRACE700\Projects \NC POWER K WILDER JOB.trc Room Checksums By MacDonald - Miller Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h ( %) Envelope Loads Skylite Solar 0 Skylite Cond 0 Roof Cond 0 Glass Solar 0 Glass Cond 0 Wall Cond -663 Partition 0 Exposed Floor 0 Infiltration -1,637 Sub Total =_> -2,300 Internal Loads Lights 0 People 0 Misc 0 Sub Total = => 0 Ceiling Load -72 Ventilation Load 0 Adj Air Trans Heat 0 Ov /Undr Sizing -3,352 Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Grand Total = => Total Capacity ton MBh Main Clg 0.4 5.0 Aux Clg 0.0 0.0 Opt Vent 0.0 0.0 Total 0.4 5.0 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB /HR MBh cfm °F °F gr/lb 4.3 0.0 0.0 237 72.8 0 0.0 0 0.0 60.2 59.0 0.0 0.0 0.0 0.0 Leave DB/WB/HR °F °F gr/lb 55.0 52.7 56.5 0.0 0.0 0.0 0.0 0.0 0.0 HEATING COIL PEAK Mo /Hr: Heating Design OADB: 26 -5,723 Floor Part ExFIr Roof Wall AREAS Gross Total Glass fi (%) 266 0 0 0 0 0 330 0 0 0 0 0 0 0 0 0 0 0 0 -825 14 0 0 0 0 -1,637 28 -2,462 41 0 0 0 0 0 0 O 0 O 0 0 0 0 0 -3,352 56 33 -1 0 0 0 0 0 0 -164 3 -5,945 100.00 TEMPERATURES Cooling Heating SADB 55.0 90.0 Plenum 72.8 67.2 Return 72.8 67.2 Ret/OA 72.8 67.2 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.0 0.0 Vent Infil Supply MinStop/Rh Return Exhaust Rm Exh Auxil AIRFLOWS Cooling Heating 0 0 35 35 237 237 0 0 272 272 35 35 0 0 0 0 ENGINEERING CKS Cooling Heating % OA 0.0 0.0 cfm /ft cfm /ton 0.89 0.89 ft /ton 633.13 Btu /hr.ft 18.95 -22.35 No. People 563.51 3 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -5.9 237 67.2 90.0 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -5.9 TRACE® 700 v6.1.2 calculated at 11:30 AM on 03/02/2009 Alternative - 1 Room Checksums report Page 1 of 3 • Room Checksums SECOND FLOOR OFFICE EAST By MacDonald - Miller Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass Cond Wall Cond Partition Exposed Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Grand Total = => COOLING COIL PEAK Peaked at Time: Outside Air: Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Reheat at Design Space Sens. + Lat. Btu /h Mo /Hr: 9 / 13 OADB/WB /HR: 74 / 61 / 61 Plenum Net Sens. + Lat Total Btu /h Btu /h 0 0 0 0 0 0 0 151 151 2,251 0 2,251 11 0 11 37 10 47 0 0 0 0 76 76 2,376 162 2,538 573 0 573 900 900 739 0 739 2,212 0 2,212 15 -15 0 0 0 0 0 0 0 0 0 -7 -7 0 0 0 4,603 140 0 0 0 Percent Of Total ( % ) 4,744 100.0 0 0 3 47 0 1 0 0 2 54 12 19 16 47 0 0 0 CLG SPACE PEAK Mo /Hr: 9 / 13 OADB: 74 Space Percent Sensible Of Total Btu /h ( %) 0 0 0 0 0 0 2,251 54 11 0 37 1 0 0 0 0 33 1 2,332 56 573 14 500 12 739 18 1,812 44 15 0 0 0 0 0 0 0 4,159 100.00 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass Cond Wall Cond Partition Exposed Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 26 Space Peak Space Sens Btu /h 0 0 0 0 -318 -184 0 0 -861 -1,364 0 0 0 0 -38 0 0 -3,981 -5,383 Coil Peak Percent Tot Sens Of Total Btu /h ( %) 0 0 0 0 -256 5 O 0 - 318 6 -237 4 0 0 0 0 - 861 15 -1,673 30 0 0 0 0 0 0 0 0 0 0 O 0 0 0 -3,981 71 17 0 O 0 0 0 0 0 45 -1 -5,591 100.00 Total Capacity ton MBh Main CIg 0.4 4.7 Aux Clg 0.0 0.0 Opt Vent 0.0 0.0 Total 0.4 4.7 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB/HR MBh cfm °F °F gr/lb 4.3 0.0 0.0 223 72.3 0 0.0 0 0.0 59.7 57.5 0.0 0.0 0.0 0.0 Leave DB/WB/HR °F °F gr/lb 55.0 52.1 54.2 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: NC POWER - ADD MITSUBISHI UNIT W/3 HP Dataset Name: C: \CDS \TRACE700 \Projects \NC POWER K WILDER JOB.trc Floor Part ExFIr Roof Wall AREAS Gross Total Glass 140 0 0 140 100 ft ( %) 0 0 12 12 TEMPERATURES Cooling Heating SADB 55.0 90.0 Plenum 72.3 67.2 Return 72.3 67.2 Ret/OA 72.3 67.2 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.0 0.0 Vent Infil Supply MinStop/Rh Return Exhaust Rm Exh Auxil AIRFLOWS Cooling 0 19 223 0 241 19 0 0 Heating 0 19 223 0 241 19 0 0 % OA cfm /ft cfm /ton ENGINEERING CKS ft /ton 354.17 Btu/hr-ft 33.88 No. People Cooling Heating 0.0 0.0 1.59 1.59 563.29 2 -39.94 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg Aux Htg Preheat Humidif Opt Vent Total -5.6 0.0 Lvg °F 223 67.2 90.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 -5.6 TRACE® 700 v6.1.2 calculated at 11:30 AM on 03/02/2009 Alternative - 1 Room Checksums report Page 2 of 3 SECOND FLOOR OFFICE WEST Room Checksums By MacDonald - Miller Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass Cond Wall Cond Partition Exposed Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Reheat at Design Grand Total =_> COOLING COIL PEAK Peaked at Time: Mo /Hr: 9 / 13 Outside Air: OADB/WB /HR: 74 / 61 / 61 Space Sens. + Lat. Btu /h Plenum Net Percent Sens. + Lat Total Of Total Btu /h Btu /h ( %) 0 0 0 0 0 0 0 0 0 151 151 3 2,251 0 2,251 47 11 0 11 0 53 13 66 1 0 0 0 0 0 0 77 77 2 2,392 165 2,557 54 573 0 573 12 900 900 19 739 0 739 16 2,212 0 2,212 46 15 -15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -7 -7 0 0 0 0 0 0 0 0 0 0 0 4,619 143 4,762 100.00 CLG SPACE PEAK Mo /Hr: 9 / 13 OADB: 74 Space Percent Sensible Of Total Btu /h ( %) 0 0 0 0 0 0 2,251 54 11 0 53 1 0 0 0 0 33 1 2,348 56 573 500 739 1,812 15 0 0 14 12 18 43 0 0 0 0 0 4,175 100.00 Internal Loads Lights 0 People 0 Misc 0 Sub Total = => 0 Ceiling Load -38 Ventilation Load 0 Adj Air Trans Heat 0 Ov /Undr Sizing -3,698 Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat System Plenum Heat Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 26 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu /h Btu /h ( %) Envelope Loads Skylite Solar 0 Skylite Cond 0 Roof Cond 0 Glass Solar 0 Glass Cond -318 Wall Cond -488 Partition 0 Exposed Floor 0 Infiltration -861 Sub Total =_> -1,667 -5,403 0 0 0 0 -256 5 0 0 -318 6 -615 11 0 0 0 0 -861 15 -2,050 37 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -3,698 66 17 0 0 0 0 0 0 0 119 -2 -5,612 100.00 Main Clg Aux Clg Opt Vent Total COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB /HR ton MBh MBh cfm 0.4 4.8 0.0 0.0 0.0 0.0 0.4 4.8 4.3 0.0 0.0 224 72.3 0 0.0 0 0.0 °F °F gr/lb 59.7 57.5 0.0 0.0 0.0 0.0 Leave DB/WB/HR °F °F gr/lb 55.0 52.1 54.2 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Dataset Name: NC POWER - ADD MITSUBISHI UNIT W/3 HP C:\CDS \TRACE700 \Projects\NC POWER K WILDER JOB.trc Floor Part ExFIr Roof Wall AREAS Gross Total Glass ft ( %) 140 0 0 140 0 0 240 12 5 TEMPERATURES Cooling Heating SADB 55.0 90.0 Plenum 72.3 67.2 Return 72.3 67.2 Ret/OA 72.3 67.2 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.0 0.0 Vent Infil Supply MinStop /Rh Return Exhaust Rm Exh Auxil AIRFLOWS Cooling Heating 0 0 19 19 224 224 0 0 242 242 19 19 0 0 0 0 ENGINEERING CKS Cooling Heating % OA 0.0 0.0 cfm /ft 1.60 1.60 cfm /ton 563.21 ft /ton 352.76 Btu/hr-ft 34.02 -40.09 No. People 2 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -5.6 224 67.2 90.0 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -5.6 TRACE® 700 v6.1.2 calculated at 11:30 AM on 03/02/2009 Alternative - 1 Room Checksums report Page 3 of 3 ACTIVITY NUMBER: M09 -019 DATE: 03 -03 -09 PROJECT NAME: NC POWER SYSTEMS SITE ADDRESS: 7220 SW 43 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued / DE � PARTME�NT �+_�r „ PUTding Di IO'� Public Works DETERMINATIO OF COMPLETENESS: (Tues., Thurs.) Complete U Comments: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 5l I•c oil Fire Prevention Structural Incomplete U ❑ Permit Coordinator ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 03-5-09 TUES /THURS R TING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: DATE: Planning Division Not Applicable Not Approved (attach comments) ❑ DUE DATE: 04-02-09 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI *988RC DIVCO INCORPORATION CONSTRUCTION CONTRACTOR GENERAL UNUSED 12/3/2002 11/7/2010 ACTIVE MACDOMR026RU MACDONALD MILLER RSDNTL INC CONSTRUCTION CONTRACTOR UNUSED GENERAL 12/31/1998 12/31 /2001 ARCHIVED MACDOMR076OPMILLER MACDONALD RESIDENTIAL CONSTRUCTION CONTRACTOR GENERAL UNUSED 9/17/1993 12/30/1998 ARCHIVED DIVCOEC188LC DIVCO ENERGY CONTROL COMPANY CONSTRUCTION CONTRACTOR GENERAL UNUSED 6/3/1982 5/26/1997 ARCHIVED MACDOM *248J9 MACDONALD MILLER CO CONSTRUCTION CONTRACTOR GENERAL UNUSED 4/29/1976 2/1/2002 ARCHIVED ENCOMMS984CA ENCOMPASS MECHANICAL SERVICES CONSTRUCTION CONTRACTOR GENERAL UNUSED 2/1/2002 2/1/2004 EXPIRED LINFOAR980QG LINFORD AIR 8 REFRIGERTN INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 11/7/2002 11/7/2004 INACTIVE DIVCOI*031L4 DIVCO INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 6/24/1997 8/1/2003 REREGISTERED Untitled Page Other Associated Licenses Business Owner Information • https://fortress.wa.gov/lni/bbip/Detail.aspx 0 General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MACDONALD /MILLER FAC SOL INC 2067684180 PO BOX 47983 SEATTLE WA 98106 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602254260 ACTIVE MACDOFS980RU CONSTRUCTION CONTRACTOR 12/31/2002 12/31/2010 GENERAL UNUSED Page 1 of 2 Name Role Effective Date I Expiration Date 04/08/2009 ExislingQpontoragg Area_20 • tie iiIii •:. iii ::•.:: ::::: •r:: :::':: :::::: IV . • 0 • • " if 11 ... 11. • iiiiii::::::::::::*33:::::.0 : : : : :** : : : : : : : : : :*: : ::: : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : 1 : : : : : : : : : : : : : : : : : : : : : : : 8 : : : : : : : : NWom.:40:::::::::::: 4 :::::: . x:x:::::::4::::::::::::::::::::::::::::::::::::::::::::::i:i:m4:om:v.::4•::4:::::::::::::::iit • . • • : $4 1. :..;. :2:4':':***:•:**:':':*:*50c*:440:44*.x.:*:*:•:"'xy.44•••••••:•:•:*.w.•••:•:4444•••••:•:•:•:•:•:•:•:•:"0:4444*:4•NIteN.:*:•:o.:44.:44.:440:444.:.:-:-xo:0•••••mo:44:0:444.:.:•:.:•:.:44410:.:.:-:•:ox.:.:.:.:.x.x.:.:.:ox.x.:4:•:.:::::::::::::::::;:x:::::4::•.::.:::::::.0::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::00.:000;:::::::::::::::::::::::0:::::::::::X:::::::::::::::::::::::::::::::::::::::::::::::::03X:X:M0KOM:MSMO .... M.: .:.: .... :44 :.:. .... g .... :.:.: :;::: V.: :: o: i ... A,. oo :0 .... e: iiii• Existing Opel) Roof i 4 .X. • • ::;•,,; i : • • i i i 4 gi • • i . • • 4 • • • • i gi ;Z. 41 .. 0 . .:. • • . • .X • • 4 I • • • • • • 4 • f • • II • • • • • • 4 • • Ii • • -• • Existingpen Roof •• •• • 4 • • • • • • 9 • : • • • • • • • • • • • K iiiii • • • • • • • • • • • • • • • • • • • • • ...K 1K . K . . 4 . K 2 Z *:i A . 2: . AN i :4*.X".:"M""...*".. r ."M"..A"""""*".""*""."*". 7 . " . " :1 * * * * * ***** * * * * * * * * * . * ! AN K.: ....." : ::: •:::: ...:.:i ',•••: Jippiqr VVIk:Way' ..:.•:-::::: ..::.,::::.::•:::.:•::-.:' . ..::.::....::-:::::.:•:::::::.:.:.:..::. • ' • :: ::::::::::: , :;:i :E? .1:: :••• ::: ::: .gi ::.... :i: iii:1 74-4)1 ::: :::. ,------1 I....._ I i —.`?■- -,........_-- sr) _., 4 r 3.: z) o: X - ! *„. ..: 0 .., '.. ''—',' 1 ,„ . : O U P . 2 0 2 . ' I I i Il ii.... C'. ) N N . \ \ - \ r , ___ 7 (_.3_ - )_„1:. t , I: ::: : §1 F ------ -----1- ------ - A \ 4 4 , ..... :•:-: Pk. :O. • • • • . • • . .... 1 2.)---- ;I: --------------_._______------''' t' 5 X ling ,Dffic Are,a ?Qi HP-2)) _Existing Offic@ Area 202 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 1 0 2009 City of Tukwila BUILDING DIVISioni MO 0 I RECEIVED CITY OF TUKVOLA MAR 0 3 2009 PERMIT CENTER ENGINEER: 0) CHECKED B. GEZ01 CAD: J. V1ONTEZ DRAWING NUMBER: — 'I 5 6 8 7396097 SHEET NUMBER: bi Cl (.6 0 LU 1 CY: w z I I I 0 0 CO z 0 0 .14 0 0 „,. CO CO LL MAnniVi LAST REVISED: DATE PLOTTED: 3/3/09 iSSIJE DATE: 3/3/09 TM2.02 lairiPITAKZUMIRMEg ‘,!;;••• ' *s.';Z•: 0 1 lark6v;;;;;Kf;:eat Women s Open Storage Area 106 t" _AiAafawwwnrvvr ANON& lifm)§~N£ • . 1,20,04S • ..a whiawmalwaffirMEMERIMENEMBINIAINIE A441 Alsomassi- Open Storage_ Area 103 ElELP F-tr.Nre f VIP C/ Outdoor Unit AC Sleg•f2 ZAREIMPISIffiff.'&::-. tiggiggAkk.w.. . V5A ARWU4komismT Office Area 103 IMF- co A WA I T.:6Q A. ) , - Peif.WVAN: .7- --------- Mgrazzim.,:aalliMPNAPI allogie afitira4:42: SIMINSIEVESEEL L wkozetax 011,6 '12 Roll Up Door Opep Shop Area 191 12' Roll Up Door Vaniandletkpii: ))* MM.1.02)W.W. REVIEWED FOR CODE COMPLIANCE APPROVED MAR 1 0 2009 City of Tukwila BUILDING DIVISION 11 0 qq) ct RECEIVED crry OF TUKVVILA MAR 03 2009 PERMIT CENTER 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 I I I I I I 1 I 1 1 1 1 1 1 1 1 (/) w 0 0 0_ Ct D c ' c i ) LLI ci) 0 0 U. 0 w OZEIP_ ENGINEER: CHECKED B Y B. GEZON CAD: J. MONTEZ DRAWING NUMBER: C-1568-7396097 SHEET NUMBER: TM2.01 Ui LAST REVISED: DATE PLOTTED: 3/3/09 ISSUE DATE: 3/3/09 z 0 0 F- co z 0 0 ct 0 LL 0 w (/) CONTACT LIST TITLE PROJECT ENGINEER ACCOUNT MANAGER FIELD FOREMAN REFRIGERATION FOREMAN OWNER REP. NAME JESSE MONTEZ KEVIN WILDER DARYL ANDERSON DEAN GRASSER JOHN STORM COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER HARNISH GROUP PHONE NUMBER 206 -768 -4288 253- 680 -3168 206 - 768 -4216 206 -768 -4270 206- 849 -7191 FAX NUMBER 206 - 768 -4289 206- 768 -4217 206- 768 -4271 SCOPE OF WORK ADD MITSUBISHI TRIPLE DUCTLESS SPLIT SYSTEM WITH WIRELESS REMOTE CONTROLS. LEGAL DESCRIPTION APN # 3623049059 LEGAL ADDRESS: 7220 SW 43RD ST, TUKWILA, WA. 98055 LEGAL DESCRIPTION :TUUKWILA LOT CONSOLIDATION L07 -087 REC 2008047001690 DAF -POR OF NE 1/4 OF NW 1/4 OF 36 -23 -04 DAF -BAAP 669.75 FT W & 30 FT N OF NE COR OF HENRY DC #43 TH WLY 66 FT ALG A LN PARALLEL. TO & 30 FT N OF N LN OF SD DC TH N 1 -39 E 120 FT'TH S 88 -21 E TO W LN OF R/R R/W TN S ALG SO W LN TAP ON A LN 30 FT N & PARALLEL TO N LN OF SD DC TH WLY ALG PARALLEL LN 'I'O POB ELECTRICAL VOLT /PH MCA, MODEL MXZ- 3A3ONA 208 -230/1 NOM. TONS INDOOR UNIT MODEL MSZ -Al2NA MSZ -AO9NA DUCTLESS SPLIT SYSTEM HEAT PUMP SCHEDULE HSPF/ SEER 10/16 10/16 208 -230/1 208 -230/1 VOLT /PH UNIT NO, DI DHP -201 MANUFACTURER MITSUBISHI MITSUBISHI MITSUBISHI S RECOMMENDATIONS: NOTES NEW ,1-7 DHP -202 NOTES 7 OU UNIT DISCONNECT AND POWER WIRING ;SO WALL UNI I S €3Y EL ECTRICAL CONTRACTOR... 2 INSTALL T HREE WALL UNITS AND OU TDOQR CONDEN IN. ACCORDAN ,WITH MANUFACTU 3 PROVID 3/4' TYPE L COPPER CONDEN DR 4 INDOOR UNITS FAC Y R AN Cl D CIR11T P RO T ECT E D FOR S OIN I NGLE PT ELECT CONN IO 5 PROVIDE WIRELESS CONTROL WHITE FINISH CONDENSATE PUMP FOR EAC,A,WALL UN 6 SINGLE OUTDOOOR "CONDENSING UNIT S ERVES DHP 101 201 AND . 7 WITH'R41C).REFRIGERANT. SEPARATE PERMIT REQUIRED FOR: p Mechanical al Electrical hl Plumbing Gas Piping City of Tukwila BUILDING DIVISION a HVAC GENERAL NOTES 1. THE HVAC SYSTEM FOR THIS PROJECT IS BASED ON THE FOLLOWING CRITERIA: ROOF °U" VALUE (BTUH /S.F. °F) = 0,044 WALL "U" VALUE (BTUH /S.F. °F) = 0.0645 FLOOR "U" VALUE (BTUH /S.F. °F) = N/A GLASS "U" VALUE (BTUH /S.F. °F) = 0.88 GLASS SHADE COEFF. = 0.60 LIGHTING (WATTS /S.F.) = 1.2 MISC. EQUIP. (WATTS /S.F,) = 0.5 PEOPLE DENSITY (S.F. /PERSON) = N/A COOLING INDOOR DESIGN TEMP ( = 72 COOLING OUTDOOR DESIGN TEMP ( "F) = 80 HEATING INDOOR DESIGN TEMP ( °F) = 68 HEATING OUTDOOR DESIGN TEMP (°F ) = 26 2. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 3. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 4. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2006 IBC. 5. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN TI lE INTEGRITY AND RATING OF THE FLOOR OR WALL. 6. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. 7. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 8. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 9. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEER NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 10.A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. 11, OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412,4.1, EXCEPT AS ALLOWED BY WSEC. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal c:n' may include additional plan review fees. City Of TUkwiia BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED MAR 10 2009 v City of (TI kwila BUILDING DIVISION FILE COPY Permit Na. O Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged BY Date: RECEIVED CITY OF TUKWILA MAR 0 3 2009 PERMIT CENTER i 0 Ct D LLB oO LL 0 0 ENGINEER: CHECKED BY CAD: J. MONTEZ DRAWING NUMBER: C-1568-7396097 SHEET NUMBER: LAST REVISED: DATE PLOTTED: B. CEZON 3 /3/09 ISSUE DATE: 3/3/09 TMO.O1