Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M09-030 - STARFIRE SPORTS
STARFIRE SPORTS 14800 STARFIRE WY M09 -030 Parcel No.: 2323049001 Address: Suite No: 14800 STARFIRE WY TUKW CityOf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: STARFIRE SPORTS Address: 14800 STARFIRE WAY , TUKWILA WA Owner: Name: TUICWILA CITY OF Address: 6200 SOUTHCENTER BLVD , TUKWILA WA Contact Person: Name: JOHN WARE Address: 4210 B ST NW SUITE F , AUBURN WA Contractor: Name: FIVE STAR MECHANICAL Address: 3902 W VALLEY HY STE 200 , AUBURN WA Contractor License No: FNESM *010JT MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: Expiration Date: 04/30/2010 DESCRIPTION OF WORK: INSTALL NEW FURNACE, GRILLS, DUCTING, THERMOSTATS AND (2) EXHAUST FANS FOR THE COACHES ADDITION Value of Mechanical: $18,792.60 Type of Fire Protection: UNKNOWN Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: I MC -10/06 EQUIPMENT TYPE AND QUANTITY 1 0 0 0 0 0 0 0 0 2 0 0 0 0 * *continued on next page ** M09 -030 Phone: Phone: 206 -786 -8278 Phone: 253- 833 -8284 M09 -030 04/13/2009 10/10/2009 Fees Collected: $400.11 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 9 Thermostat 2 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 04 -13 -2009 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Print Name: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Geri. (d to,d!R-.1 u r . Permit Number: M09 -030 Issue Date: 04/13/2009 Permit Expires On: 10/10/2009 Date: L k — t VO -/ Date: `/ f �^ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -030 Printed: 04 -13 -2009 Parcel No.: 2323049001 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 14800 STARFIRE WY TUKW STARFIRE SPORTS 1: ** *BUILDING DEPARTMENT CONDPI`fONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M09 -030 ISSUED 03/20/2009 04/13/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M09 -030 Printed: 04 -13 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: 1 �--L-e Date: 1 3y "LJ G( doc: Cond -10/06 M09 -030 ordinances governing or local laws regulating Printed: 04 -13 -2009 Site Address: Tenant Name: Property Owners Name: Mailing Address: Contact Person: --) E -Mail Address: Contractor Registration Number: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SIM LOCATION CONTACT PERSON -who dove c antact w hen your per mit;is ready to be issued Name: ,.....)6\/\,,■ Mailing Address: Zip E -Mail Address: ' Ayvtec 1 1 , C OM Fax Number: u - a • • . • MECHANICAL CONTRACTOR INFORMATION Company Name: \ ) Q , S c(A_ 1 �� ` k `` c. Lit ti cot_ � k Mailing Address: L) � � S - Iv W S pa_ �' itAt1 �'l, GU State City Zip /� Day Telephone: -{7 7I 7U ak/t. Fax Number: Expiration Date: • e-C w1 01 T H:\Applications \Forms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Mechanical Permit No. ` 30 Project No. (For office toe only) King Co Assessor's Tax No.: 95/490041k Suite Number: Floor: New Tenant: ❑ Yes City City State State Zip Day Telephone: Z4 ' 7 CJu - e927 .926 10 C ARCffi'TECT OF RECORD ATI plans must be wet stamped by Architect of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: ENGINEER OF RECORD -- All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 of 2 Unit Type: ` Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU i Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct ^7 d\ Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator - Comm /Ind Valuation of Project (contractor's bid price): $ 1 V ► 7 . A-0 Scope of Work please provide detailed information): Ait CC) c,-(. .w c\ y OA , Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric ❑ Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICA NO - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDI R 0 AU . 0 E l AGENT: Signa 11 Print Nam r�V� l/� - Mailing Address: yV kO . C , . ■■., CU0e Date Application Expires: Date Application Accepted: , ✓ .)-0-(') " (t Gas H: Applications \Forms-Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Other: City Date: Day Telephone: 204 7g6,- c3 2 713 ),Wt e tSwk State Zip Staff Initials: W Page 2 of 2 Receipt No.: R09 -00446 Initials: WER User ID: 1655 Payee: FIVE STAR MECHANICAL ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 32361 400.11 RECEIPT Parcel No.: 2323049001 Permit Number: M09 -030 Address: 14800 STARFIRE WY TUKW Status: PENDING Suite No: Applied Date: 03/20/2009 Applicant: STARFIRE SPORTS Issue Date: Account Code Current Pmts 000.322.102.00.0 320.09 000/345.830 80.02 Total: $400.11 Payment Amount: $400.11 Payment Date: 03/20/2009 09:25 AM Balance: $0.00 PAYMENT RECEIVED doc: Receipt -06 Printed: 03 -20 -2009 Project: 7'r / P6 .S9d /1 75 S �J Type of Inspection: i t- i i v q / Q Address: / 5/8OU - 57 -//•Pr iec� to Called: Special Instructions: / Date M ted: /— / 7— d 5 a.m p.m. Requester: Phone No: mod; - 7 - 7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISI ON R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspec Dater s, ef $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.:'. Date: I Project: -.3 i2 r /WE -5 /lop? TS Type of Inspection: I.?0/66/ I /I Address Date Called: Special Instructions: f Date Wanted: 4/ / 6 "" 6 (6m; p.m. Requester: Phone No: 77 9 / S .4* INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: k-- LA) LJ I r 011 C -v ✓-P !` coo ^1 Inspector: Date / _ 7 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: a TUX2 PRODUCT SPECIFICATIONS® MODEL CI U) T u k wi l a TUX2B060A9362A TUX2B080A94220 TUX2C100A9482A REVIEWED FOR CODE COMPLIANCE APPROVE APR 0 2 2009 1st Stage Capacity BTUH (ICS)® 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS)® AFUE+''(ICS)1 Temp. Rise (Min. -Max.) °F. BLOWER DRIVE Dia: Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP RP.M. Volts/Ph/Hz COMBUSTION FAN -TYPE Drive - No. Speeds Motor HP - RPM Volts/Ph/Hz FL Amps ALTER — Furnished? Type Recommended Filter (No.-Size-Thk.) VENT — Size (In.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES — Main Nat. Gas. Qty. —Drill Size LP. Gas Qty. — Drill Size GAS VALVE DIRECT IGNITION DEVICE Type BURNERS —Type Number POWER CONN.— V/Ph/Hz0 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DUCT CONN. DIMENSIONS Crated (In.) Uncrated WEIGHT Shipping (Lbs.)/Net (Lbs.) DIVISInN 19000 36000 60000 56000 93.0 30 - 60 DIRECT 10 x 7 1 4 SEE FAN PERF. TABLE 1/3 1075 115/1/60 CENTRIFUGAL DIRECT - VARIABLE 1/15 - 5000 33 - 110/3/60 - 180 1.0 NO HIGH VELOCITY 1 - 17 X 25 - 1 IN 2 ROUND ALUMINIZED STEEL TYPE 1 ALUMINIZED STEEL TYPE 1 20 3 -45 3 -56 REDUNDANT - TWO STAGE HOT SURFACE IN -SHOT 3 115/1/60 8.7 15 1/2 SEE OUTLINE DRAWING HXWXD 41 -3/4 X 19 -1/2 X 30 -1/2 SEE OUTLINE DRAWING 158 / 146 General Data 52000 48000 80000 73000 ;;92 r 35 -65 DIRECT 10x8 1 4 SEE FAN PERF. TABLE 1/3 1075 115/1/60 CENTRIFUGAL DIRECT - 1 1/15 - 5000 33 - 110/3/60 - 180 1.0 NO HIGH VELOCITY 1 - 17 X 25 - 1 IN 2 ROUND 20 4 -45 4 -56 REDUNDANT - TWO STAGE HOT SURFACE IN -SHOT 4 115/1/60 9.5 15 1/2 SEE OUTLINE DRAWING HXWXD 41 -3/4 X 19 -1/2 X 30 -1/2 SEE OUTLINE DRAWING H003O 65000 60000 100000 93000 93.0 35 -65 DIRECT 10 x 10 1 4 SEE FAN PERF. TABLE 1/2 1075 115/1/60 CENTRIFUGAL DIRECT - VARIABLE 1/15 - 5000 33 - 110/3/60 - 180 1.0 NO HIGH VELOCITY 1 - 20 X 25 - 1 IN 2 ROUND 20 ALUMINIZED STEEL TYPE 1 5 -45 5 -56 REDUNDANT - SINGLE STAGE HOT SURFACE IN -SHOT 5 115/1/60 13.1 20 1/2 SEE OUTLINE DRAWING HXWXD 41 -3/4 X 23 X 30-1/2 SEE OUTLINE DRAWING 168 / 197 / 185 ()Central Furnace heating designs are certified by AGA and CSA. ® For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. ® Based on U.S. government standard tests. ()The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. TUX2D1 20A9602A 72000 66600 120000 112000 92.5 40 -70 DIRECT 11 x 10 1 4 SEE FAN PERF. TABLE 3/4 1100 115/1/60 CENTRIFUGAL DIRECT - VARIABLE 1/15 - 5000 33 - 110/3/60 - 180 1.0 NO HIGH VELOCITY 1 - 24 X 25 - 1 IN 3 ROUND ALUMINIZED STEEL TYPE 1 20 6 -45 6 -56 REDUNDANT - SINGLE STAGE HOT SURFACE IN -SHOT 6 115/1/60 13.5 20 1/2 SEE OUTLINE DRAWING HXWXD 41 -3/4 X 26 -1/2 X 30 -1/2 SEE OUTLINE DRAWING 206 / 193 sea level. For Canadian RECEIVED MAR 2 0 2009 PERMIT CENTER Pub. No. 22-1705-03 FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 TUX2B080A9422A 4 - HIGH - Black 1748 1683 1615 1544 1470 1393 1314 1232 1147 TUX2B080A9422A 3 - MED. -HIGH - Blue 1375 1367 1347 1314 1268 1210 1139 1056 960 2 - MED. -LOW - Yellow 1178 1167 1147 1119 1082 1036 982 919 847 1 - LOW - Red 859 863 856 839 811 772 723 663 592 CFM VS. TEMPERATURE RISE Cubic Feet Per Minute CFM) MODEL 1100 1200 1300 1400 1500 1600 1700 TUX2B080A9422A 61 56 51 48 45 44 42 TRAM' 3/4" TAG: 4- 9/16" 9 -1/2" 1 1/2" 2- 1/16" 3 -3/4" 19 -1/2" 17 -1/2" 16-1/4" ✓ 5/8" 19 -5/8" 2° DIAMETER 5/8 OUTSIDE AIR 4 3/4" 7/8° DIA. HOLES ELECTRICAL CONNECTION 16 1 -7/8° X 7/8° SLOT K.O. CONDENSATE DRAIN 24 (FOR HORIZONTAL) 1 -1/8° DIA.K.O. CONDENSATE DRAIN (Rt. Side Alternate © 2006 American Standard Inc. 5/8" 28 -1/2" 5- 5/16" 1 -1/2" DIA. HOLE GAS CONNECTION SUBMITTAL Upflow / Horizontal Direct or Non - Direct Vent 2 Stage Gas Furnace 2" DIAMETER FLUE CONNECT 2 -1/8" • 1/2" 40" TUX2B080- SUB2 -1 TUX2B080A9422A 7/8" DIA. K.O. ELECTRICAL CONNECTION (ALTERNATE) 1 1/2" DIA. K.O. GAS CONNECTION (ALTERNATE) TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 Tema. rise (Min. -Max.) °F. BLOWER DRIVE Diameter -Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts/Ph/Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts/Ph/Hz F.L. Amps FILTER — Furnished? Type Recommended Hi Vel. (No.- Size -Thk.) Shipped NATURAL GAS MODELS — Central heat- ing furnace designs are certified by the American Gas Association for both natu- ral and L.P. gas. Limit setting and rating data were established and approved un- derstandard rating conditions using Ameri- can National Standards Institute standards. SAFE OPERATION — The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combi- nation gas valve and regulator provide extra safety. QUICK HEATING Durable, cycle tested, heavy gauge aluminized steel heat ex- changer quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside, allows com- mon venting with hot water heater. SinceTrana hasa policy of continuous product and product data Improvement, it reserves the right to change specifica- tions and design without notice. Technical Literature - Printed in U.S.A. Trane A business of American Standard Companies www.trane.com Upflow / Horizontal 52,000 48,000 80,000 73,000 35 - 65 DIRECT 10x8 1 4 See Fan Performance 1/3 1075 115/1/60 Centrifugal Direct - VARIABLE 1/50 - 5000 33- 110/3/60 -180 1.0 No High Velocity 1 - 17x25 - 1 in. General Data ® VENT COLLAR — Size (In.) HEAT EXCHANGER Type -Fired - Unfired Gauge (Fired) ORIFICES — Main Nat.Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V/Ph/Hz Ampacity (In Amps) Max. Overcurrent Protection (amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) Uncrated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) O Central Furnace heating designs are certified by the American Gas Association Inc. Laboratories. 0 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level. 0 Based on U.S. Government Standard Tests. 0 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Mechanical Specifications BURNERS — Multi -port, in -shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL Ex- clusively designed operational program pro- vides total control of furnace limit sensors, blowers, gas valve, flame control and in- cludes self diagnostics for ease of service. AIR DELIVERY — The multispeed, direct - drive blower motor, with sufficient airflow range for most heating and cooling re- quirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. (Fan relay and 35VA control transformer is stan- dard). 2 Round Alum. Steel 20 4 -45 4 -56 Redundant - Two Stage Hot Surface Ignition Multiport Inshot 4 115/1/60 9.5 15 1/2 HxWxD 41 -3/4 x 19 -1/2 x 30 -1/2 40 x 17 -1/2 x 28 -1/2 168/1561: STYLING — Heavy gauge steel and "wraparound" cabinet construction is used in the cabinet with baked -on enamel finish for strength and beauty. The heat exchanger section of the cabinet is com- pletely lined with foil -faced fiberglass insu- lation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. FEATURES AND GENERAL OPERA- TION — These High Efficiency Gas Fur- naces employ a Hot Surface Ignition sys- tem, which eliminates the waste of a con- stantly burning pilot. The integrated sys- tem control lights the main burners upon a demand for heat from the room thermo- stat. Complete front service access. a. Low energy power venter. b. Vent proving differential switch. Model A C U E F Metal Gauge Avg Wt. Ube.) Energy Star FG4 3' /a 8 3'4 6Y 1 1 22 7 ✓ FG 4XL 3 7 /6 9 3 /4 6 1 3/46 1 1 22 8 FG5 4% 8 5 1 1 22 7 / FG 5XL 4% 9 5 1 3/46 1 1 22 8 FG 6 5% 11 3 /e 6 1 1 22 10 ✓ FG 6M 5% 13% 6 1 1 22 12 ✓ FG 6XL 5 % 13 1 /e 6 1 1 22 12 ✓ FG8 7% 13 6 1 % 1 22 12 ✓ FG8XL 7 %/e 13% 6 1 1 22 13 ✓ FG10 9% 13 Y 4 1 % 1 22 12 ✓ FG10XL 9% 13 5% 1 % 1 22 14 ✓ FG 12 11 % 16 8 1 /4 1 1 /16 1 3 /46 22 18 ✓ FG 12XL 11 % 16 8 1 /4 1 1 /16 1 3 /46 22 21 ✓ Accessory Items, 1 Fan Speetffsatiene ' Meter Reifications Line Qty Model No. Tag CFM SP Fan RPM Watts Volts Phase Hertz Encl 1 ❑ ❑ 2 ❑ ❑ 3 ❑ ❑ 4 ❑ ❑ 5 ❑ Accessory Items, 1 2 3 4 5 Accessory Items ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 7 Fantech SUBMITTAL DATA FG SERIES Inline Centrifugal Fans STANDARD FEATURES • Airtight galvanized steel housing • Powered by external rotor motorized impeller • Permanently lubricated sealed ball bearings • 100% speed controllable • Automatic reset thermal overload protection • Prewired electrical box • Five -year factory warranty All dimensions in inches. 1oo�, M CERTIFIED' Look for Energy Star models in dimensional data chart. US Project: Submitted: Customer: Approved: Location: United States 1712 Northgate Blvd. • Sarasota, FL. 34234 • www.fantech.net Article 8 450369 Fantech Canada 50 Kanalflakt Way • Bouctouche, NB E4S 3M5 • 1.800.565.3548 • www.fantech.ca Rev Date 041508 Fentech, reserves the right to modify, at any time and without notice, any or all of its products' features, designs, components and specifications to maintain their technological leadership position Fantech FG Series Fans Description A centrifugal type exhaust/supply fan specifically designed for moderate size ventilation applications. The fan can be mounted at any angle in any point along the duct work and straight - through air flow design allows easy installation. By using FC type mounting clamps, fan can be easily removed from duct work for service. Fans are constructed in accordance with standard dimensions for spiral duct eliminating the need for transition pieces. Fan motors are capable of operating in air stream temperatures up to 140 F. Motor bearings are a permanently sealed, self lubricating ball type. All fans are 100% speed controllable through a decrease in the voltage by using a solid state or transformer type control. All FG Series fans are backed by Fantech's Five Year Warranty. Guide Specifications for Model FG Inline Duct Fans Supply, exhaust or return air inline fans shall be of the centrifugal, direct driven type. Construction Housing • Fan housing shall be constructed of heavy gauge galvanized sheet metal. • Fan shall be supplied with externally mounted electrical terminal box with pre -wired terminal strip connections. • Capacitor shall be located within electric terminal box. Motor • Motorized impeller shall be an external rotor type, class B insulation, enclosed with permanent split capacitor. • Motor shall be a permanently sealed self lubricating ball bearing type. • Motor shall be equipped with automatic reset thermal overload protection. • Motor shall be acceptable for continuous duty. Wheel • Fan wheel shall be of the backward inclined centrifugal type with a well designed inlet venturi for maximum performance. • Motorized impeller shall be both statically and dynamically balanced as one integral unit to provide for vibration free performance. • Impellers shall be molded of high impact polypropylene. Performance • Fan air flow performance shall be based upon tests conducted in accordance with AMCA Standard 211 and 311 and shall be licensed to bear the AMCA Certified Ratings Label. Code Approval • Fan shall be tested and approved by UL and CSA (or equal) for safety. FG Series shall be manufactured under the authority of Fantech, Inc., Sarasota, FL. Fantech United States • 1712 Northgate Blvd. • Sarasota FL 34234 • 1- 800 - 747 -1762 • www.fantech.net Canada • 50 Kanalflakt Way. • Boutouche, NB E4S 3M5 • 1-800- 565 -3548 • www.fantech.ca Furnace - 1 System Checksums By MTW Design Services Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass Cond Wall Cond Partition Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Dehumid. Ov Sizing Ov /Undr Sizing Exhaust Heat Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup Underflr Sup Ht Pkup Supply Air Leakage Grand Total =_> COOLING COIL PEAK Peaked at Time: Outside Air: OADB/WB /HR: 80 / 64 / 64 Space Sens. + Lat. Btu /h 0 0 0 2,327 142 20 0 0 0 0 2,489 2,272 2,288 2,840 7,399 2,199 0 0 0 12,088 Plenum Sens. + Lat Btu /h 0 0 1,665 0 0 0 0 0 0 1,665 9 2,327 12 142 1 -32 -12 0 0 0 0 0 0 0 0 0 0 4,122 22 1,632 568 0 0 568 -2,199 0 Mo /Hr: 7 / 15 0 0 0 0 Net Percent Total Of Total Btu /h ( %) 2,840 15 2,288 12 2,840 15 7,967 42 0 6,707 0 0 0 0 0 0 0 0 0 0 36 0 0 0 0 0 0 0 0 0 1 18,795 100.00 CLG SPACE PEAK Mo /Hr: Sum of OADB: Peaks Space Percent Sensible Of Total Btu /h ( %) 0 0 0 0 0 0 3,790 30 124 1 288 2 0 0 0 0 0 0 0 0 4,202 33 2,272 1,144 2,840 18 9 22 6,255 49 2,246 0 0 0 18 0 0 0 12,704 100.00 Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass Cond Wall Cond Partition Floor Adjacent Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Ventilation Load Adj Air Trans Heat Ov /Undr Sizing Exhaust Heat OA Preheat Diff. RA Preheat Diff. Additional Reheat Underflr Sup Ht Pkup Supply Air Leakage Grand Total = => HEATING COIL PEAK Mo /Hr: Heating Design OADB: 26 Space Peak Space Sens Btu /h 0 0 0 0 -1,859 -1,506 0 0 0 0 -3,366 0 0 0 0 -1,321 0 0 0 -4,687 Coil Peak Percent Tot Sens Of Total Btu /h ( %) 0 -1,158 0 -1,859 -1,670 0 0 0 0 -4,687 0 0.00 0,00 3.55 0 00 5.70 512 0 00 0 00 0 0 00 14.36 0 0 00 0 0 00 0 0 00 0 000 0 0 00 - 27,949 85 64 0 0 0 000 0 0.00 0 0 00 0 0.00 0 0 00 0 0.00 0 0 00 - 32,636 100 00 Total Capacity ton MBh Main Clg 1.6 18.8 Aux Clg 0.0 0.0 Opt Vent 0.0 0.0 Total 1.6 18.8 COOLING COIL SELECTION Sens Cap. Coil Airflow Enter DB/WB/HR MBh cfm °F °F gr /Ib Leave DB/WB/HR °F °F gr /Ib 14.0 578 79.9 64.0 65.1 55.0 53.0 57.6 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: Coach Addition at Starfire Complex Dataset Name: W: \09 PROJECTS \0902 - Starfire Revisions \0902 -hvac load.trc Floor Part ExFlr Roof Wall AREAS Gross Total Glass ft ( % 832 0 0 832 0 0 980 81 8 Variable Temperature Constant Volume SADB Ra Plenum Return Ret/OA Fn MtrTD Fn BIdTD Fn Frict TEMPERATURES Cooling 55.0 83.3 83.6 80.0 0.0 0.0 0.0 Heating 77.4 65.0 65.0 26.0 0.0 0.0 0.0 Diffuser Terminal Main Fan Sec Fan Nom Vent AHU Vent Infil MinStop/Rh Return Exhaust Rm Exh Auxiliary Leakage Dwn Leakage Ups AIRFLOWS Cooling 578 578 578 0 578 578 0 0 0 0 578 0 0 0 Heating 578 578 578 0 578 578 0 0 0 0 578 0 0 0 ENGINEERING CKS % OA cfm /ft cfm /ton ft /ton Btu /hrft No. People Cooling 100.0 0.69 369.08 531.20 22.59 4 Heating 100.0 0.69 -39.23 HEATING COIL SELECTION Capacity Coil Airflow Ent MBh cfm °F Main Htg -32.6 578 26.0 Aux Htg 0.0 0 0.0 Preheat -18.4 578 26.0 Humidif 0.0 Opt Vent 0.0 Total -32.6 Lvg °F 77.4 0.0 55.0 0 0.0 0.0 0 0.0 0.0 TRACE® 700 v6.2 calculated at 01:16 PM on 03/09/2009 Alternative - 1 System Checksums Report Page 1 of 1 DEPARTMENTS: Cr t *0 dirid Division Public Works Complete Comments: REVIEWER'S INITIALS: Documents /routing slip.doc 2 -28 -02 wirr ilfic-D if • PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Structural Incomplete Approved Approved with Conditions Notation: REVIEWER'S INITIALS: ACTIVITY NUMBER: M09 -030 PROJECT NAME: STARFIRE SPORTS SITE ADDRESS: 14800 STARFIRE WAY X Original Plan Submittal Response to Correction Letter # DATE: 03 -20 -09 Response to Incomplete Letter # Revision # After Permit Issued A 141 N/4 3 Fire Prevention DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DATE: DATE: Planning Division Permit Coordinator DUE DATE: 03-24 -09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS R TING: Please Route Structural Review Required n No further Review Required DUE DATE: 04 -21 -09 n Not Approved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status COMFOMI015LA COMFORT MECHANICAL INC CONSTRUCTION CONTRACTOR HTG /VENT /AIR CONDITIONING UNUSED 6/1/1999 6/1/2010 ACTIVE COMFOP*064D2 COMFORT PLUS CONSTRUCTION CONTRACTOR AIR CONDITIONING AIR HEAT,VENTILATION,EVAPORAT 3/22/1994 3/21/2000 ARCHIVED FIVESSE941KU FIVE STAR ENERGY SOLUTIONS CONSTRUCTION CONTRACTOR GENERAL UNUSE 5/24/20065/24/2008 04/27/1999 EXPIRED Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 FEDERATED MUTUAL INS CO 9899743 06/25/2006 Until Cancelled $12,000.0006/05 /2006 2 OLD REPUBLIC SURETY CO YLI23759104/30/2002Cancelled Until 06/25/2006 $12,000.0003/04 /2002 1 OLD REPUBLIC SURETY CO YLI237591 04/27/1999 04/30/2002 $6,000.00 03/19/2001 Untitled Page Other Associated Licenses Business Owner Information Bond Information Insurance Information • • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company FIVE STAR MECHANICAL 2538528284 4210 B ST NW STE F AUBURN WA 980011717 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601937083 ACTIVE FIVESM *010JT CONSTRUCTION CONTRACTOR 4/30/1999 4/30/2010 GENERAL UNUSED Page 1 of 2 Name WARE, GERALD L Role Effective Date 01/01/1980 Expiration Date I lnsurancel Company I Policy I Effective I Expiration jCancelImpaired Amount I Received https: // fortress .wa.gov /lni/bbip/Detail.aspx 04/13/2009 GAS -FIRED FURNACE SCHEDULE EXHAUST FAN SCHEDULE UNIT NO MFR. MODEL LOCATION CONFIGURATION AREA SERVED PERFORMANCE BACKDRAFT DAMPER SPEED CONTROL CONTROLLED BY OR INTERLOCKED WITH ELECTRICAL STARTER FURN. BY DISCONNECT FURN. BY WEIGHT (LBS) REMARKS HP EX. S.P. RPM AMPS VOLTS 0 TRANE TUX2B- 080A9 -422A EQUIP /LAUN 113 EF -1 FANTECH FG8XL 113 INLINE LOCKER ROOM 115 465 0.25 1000 NO YES Q5 1.45 120 1 EC EC 50 0®® EF -2 FANTECH FG10XL 113 CEILING LAUNDRY /EQUIP 113 525 0.5 1080 NO YES Q4 1.96 120 1 EC 50 0001 GAS -FIRED FURNACE SCHEDULE UNIT NO MFR. MODEL LOCATION INPUT MBH EFFICIENCY % CFM MIN. OSA MOTOR WEIGHT LBS. INTERLOCK ELECTRICAL STARTER FURN. BY DISCONNECT FURN. BY REMARKS RPM HP MCA MOP VOLTS 0 F -1 TRANE TUX2B- 080A9 -422A EQUIP /LAUN 113 80 90 1200 480 - 3/4 - - - - 120 1 EC EC 00000 6O DUCT INSULATION SCHEDULE N INSULATION R -VALUE NOT *THIN CONDITIONED SPACE ON EXTERIOR OF BUILDING, OIr R AC IN ENCLOSED CEILING SPACE, IN WALLS, IN GARAGE, F NOT *ITHIN CONDITIONED SPACE: IN CONCRETE, IN GROUND HvAC EQUIPMENT NUMI5ER/ PLUMING FIXTURE DESIGNATION Iljr 24/12 RECTANGULAR DUCT SIZE 12 "'4 ROUND /SPIRAL DUCT SIZE SIDE WALL DIFFUSER/GRILLE II -1- RETURN/EXHAUST/TRANSFER GRILLE SUPPLY AIR ARROW <-- RETURN AIR/EXHAUST ARROW 0 THERMOSTAT /SENSOR lZEI RET/EXH DUCT DOWN (4) RET/EXH DUCT UP ( *) J ROUND /SPIRAL DUCT DOWN X 41 CU ROUND /SPIRAL DUCT UP (4) 01 RECT ELBOW w/TURN vANES F RADIUS ELBOW Cs / 4) i TRANSITION * = SQUARE- ROUND TRANSITION ' vOLUME DAMPER (vD) I I ci MOTORIZED DAMPER OSA OUSTIDE AIR MO FURNISHED BY OTHERS AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE DUCT INSULATION SCHEDULE DUCT LOCATION INSULATION R -VALUE NOT *THIN CONDITIONED SPACE ON EXTERIOR OF BUILDING, OIr R AC IN ENCLOSED CEILING SPACE, IN WALLS, IN GARAGE, R -7 NOT *ITHIN CONDITIONED SPACE: IN CONCRETE, IN GROUND R -5.3 SUPP AIR DUCTS WITHIN ONDITIONED SPACE �ATH HVAC EQUIPMENT SUPPLY AIR TEIy PERAT1JRE <55 OR >105'F R -3.3 I 12 12/12 12/6 OPENING w/SCREEN 12" SCREEN — '• 12 " FLOOR COMBUSTION AIR DETAIL „ ROOF Hoot) 12/6 INTERLOCK DAMPER WITH DRYER DRYER MAKE -UP AIR DETAIL MAKE -UP AIR DETAILS M NOTE: REQUIREMENTS APPLY TO BOTH SUPPLY AND RETURN DUCTS, WHETHER HEATED OR ECHANICALLY COOLED. MECHANICALLY COOLED DUCTS REQUIRING INSULATION SHALL HAVE A VAPOR RETARDER, WITH A PERM RATING NOT GREATER THAN 0,5 AND ALL JOINTS SEALED. 1. *ITH APPROVED 4JEATHERPROOF BARRIER. R V ES ARE FOR THE INSULATION AS INSTAALLED AND DO NO THICKNESS. AIR FILM RESISTANCE. INSTALLED: R -3,3 1.0 INCH 1,5 TO 3 LB /CU,FT, DUCT LINER, MINERAL QR GLASS FIBER BLANKET OR EQUIVALENT TO PROVIDE AND INSTALLED TOTAL THERMAL RESISTANCE OF AT LEAST R -3.3 R -5.3 2,0 INCH 0.75 LB /CU.FT. MINERAL OR GLASS FIBER BLANKET, 1.5 INCH 1.5 TO 3 /CU,FT. DUCT LINER, MINERAL OR GLASS FiBER BLANKET, 1,5 INCH 3 TO 7 LB /CU,FT. MINERAL OR GLASS ABER BOARD OR EQUIVALENT TO PROVIDE AN INSTALLED TOTAL THERMAL RESISTANCE OF AT LEAST R -5,3 R -7 3 INCH 0.75 LB /CU,FT, ,I4INERAL OR GLASS FIBER BLANKET, 2 -INCH 1.6 TO 3 LB /CU.FT. DUCT LINER, MINERAL OR GLASS FIBER BLANKET, 2 -INCH 3 TO 7 LB /.CU.F T THERMAL RESISTANCE OF AT LEAST R -7. dRILLE &DIFFUSER $01EDULE TITUS L SIZE AS No TED To • Thus «I. SIZE AS NOTED TG • TI1u6 -F, SIZE AS NOTED siFRAPE FOR T -BAR C iLiNs EGG • AIM sEeRi, SIZE A5 No p 6GM • TITUS Iritt EGGCRAIE GRILLE elk OMER, SIZE AS NOTED (W • DESIGNATES GRILLE OR DOWER u/SORDER FOR GYPSUM BOALO CEILING iNSTAU ATION • 2 -STAGE WITH INTERMITTENT PILOT. 2 NATURAL GAS- FIRED. PROVIDE WITH PRESSURE REGULATORS TO REDUCE 2 PSI DELIVERY PRESSURE TO 10" WC. VENT REGULATORS TO ATMOSPHERE. • PROVIDE WITH STAINLESS STEEL HEAT EXCHANGERS. 0 UNIT TO BE SEPARATED COMBUSTION TYPE. 0 PROVIDE 7 -DAY PROGRAMMABLE T -STAT, SET HOURS OF OPERATION PER OWNER'S SCHEDULE. PROVIDE w /MANUAL 4 HOUR OVERRIDE. • PROVIDE w /2- POSITION MOTORIZED RA & OSA DAMPERS. SET OSA DAMPER TO PROVIDE MINIMUM OF 500 CFM OSA DURING NORMAL OCCUPIED HOURS. OSA DAMPER SHALL CLOSE DURING UNOCCUPIED SCHEDULE. 1O ALL EXHAUST FANS TO BE WIRED FROM MOTOR TO BOX ON EXTERIOR OF FAN ENCLOSURE. 0 SPEED CONTROL TO BE FACTORY WIRED TO THE OUTSIDE CABINET OF IN -LINE FANS. O3 EC TO PROVIDE A MANUAL STARTER (INCLUDING DISCONNECT). O4 CONTROL VIA LINE VOLTAGE REVERSE ACTING T -TSTAT SET TO ENERGIZE AT 75°F (ADJUSTABLE). COORDINATE w /E.C. ® PROVIDE CONTROL VIA WALL MOUNTED OCCUPANCY SENSOR. REVISIONS No changes shall be dam a to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal end may includes additional plan review fees. LOCKER RM 12x12 CP I 300 CFM 120" GAS SERVICE E3Y PLG CCNT'R 16/16 OSA DUCT UP TO INTAKE ROOF HOOD 16 0" Illf r t 20/12 -/ — 12x8 "ADS ! 150 CFM 20/12 �• .d `� DUG _ — T . SCREEN F Orion 23.5 dia. x 19.5 1_ — 1 Cnr SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVIEWED R CODE COMPLIANCE APPROVED j APR 0 2 2009 City oft l tJkwlla BUILDING DIri� inn, I F 1/4" = 1 - 0 " 10/10 UP TO ROOF CAP. 12/12 UP TO ROOF HOOD 4 DUCTED DOWN TO 12" BELOW CEILING. PROVIDE 12/6 DUCT TAP TO CEILING DOWN TO 12" AFF. TERMINATE 60T4 DUCTS WITH SCREEN, .SEE DETAIL THIS SHEET,. 10/1 PARTIAL HVAC FLOOR PLAN r EQUIP,/LAUN B -- - - -- 113 but FLUE (TYPE "B ") UP TO ROOF HOOD. COORDINATE LOCATION w/INTAKES TO PROVIDE A MINIMUM OF 10 L.P. CLEARANCE. 12/10 12x8 SD& 350 CFM 120" 12x8 SDS 350 CFM I ® II 1 I J 12/6 EXIS 1 CT VENT WATER HEATE=RS (TYP. Of 3) MECH 116 8x8 TGH 24/12 OSA DUCT UP TO INTAKE ROOF HOOD. TERMINATE 12" AFF WITH SCREEN. SEE DETAIL. MO9 0 30 I I I I I I I E 4 COMB F -1 INTERLOCK TO DRYE -- I II 1... I rr Massini cr 37 x 39 x 0 2' 4' FILE COPY Permit No. NIIGI - Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fie Copy ay ens is acknowledged: By 7 Date: City Of Tukwila BUILDING DIVISION RECEIVED MAR .2 0 2009 PERMIT CENTER 8' elle SCALE: 1/4" = 1' -0" 0 0 CO CO • t I c � L co 4 N c o ( LO a) Q 0 a) w 0 CtS F-1 0 DRAWING NO. M -1 U) z 0 w U) 0 Q . ow- 0 0 I4 Pci C) 0 co itu 1-4 as O E-1+ DATE 07/07/08 DRAWN CHECKED PROJECT NO. CONTRACT DRWG. REF.