HomeMy WebLinkAboutPermit M09-036 - KING COUNTY DATA CENTERKJNG COUNTY DATA CENTER 3355 S 120 PL M09 -036 Parcel No.: 1023049069 Address: Suite No: doc: IMC -10/06 3355 S 120 PL TUKW Contact Person: Name: LOU BAILEY Address: 5005 3 AV S , SEATTLE WA Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA Contractor License No: MCKINCL942DW DESCRIPTION OF WORK: PROVIDE AND INSTALL 7 -TON SPLIT A/C UNIT Value of Mechanical: $58,379.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial Cit'.ligf Tukwila Tenant: Name: KING COUNTY DATA CENTER Address: 3355 S 120 PL , TUKWILA WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 1 0 0 0 0 0 0 0 * *continued on next page ** M09 -036 1 Permit Number: M09 -036 Issue Date: 04/16/2009 Permit Expires On: 10/13/2009 Phone: Phone: 206 396 -9764 Phone: (206)762 -23311 Expiration Date: 03/16/2010 Fees Collected: $860.19 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 04 -16 -2009 Permit Center Authorized Signature: I hereby certify that I have read and ex governing this work will be complied The granting of this permit does not pres construction or the •; rformanc- of work. Signature: ��Lal. Print Name: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: MO9 -036 Issue Date: 04/16/2009 Permit Expires On: 10/13/2009 Date: 0 6U: d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -036 Printed: 04 -16 -2009 Parcel No.: 1023049069 Address: Suite No: Tenant: doc: Cond -10/06 3355 S 120 PL TUKW 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 14: ** *FIRE DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us KING COUNTY DATA CENTER 5: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. M09 -036 ISSUED 04/06/2009 04/16/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. M09 -036 Printed: 04 -16 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 17: H.V.A.C. systems supplying air m excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 18: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 19: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 20: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 21: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 23: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M09 -036 Printed: 04 -16 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: jg S5 Print Name: C S doc: Cond -10/06 M09 -036 Date: L ordinances governing or local laws regulating Printed: 04 -16 -2009 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No. i 01:36 'f ? 069 Site Address: ?J7+ �S s ' 10 r Suite Number 510 1 Floor: 2 n Tenant Name: k . ry / Co) M bia A 6e5V ital, New Tenant: ❑ Yes tir..No Property Owners Name: Sia 604 Gd *+- e _ Mailing Address: 1 2101 Tv IL1,. )t A- ' iv A. ill vc ` D k t) 71 A W 4. 9 V 1 g City State Zip Name: L O iA . S3-1t ik . kve_ Sty Mailing Address: E -Mail Address: 01 4 6 @� f) .JL1 N T2y, L0 en Company Name: (Y% '41 rv- G o . Mailing Address: Company Name: Mailing Address: P. O, 6 l 24 s 1 � 0Ub @Y» 1rvS 171141 • t: Contact Person: E -Mail Address: Contractor Registration Number: Al (X.1 N G L 1 q / Z Q W (, I 1 ,So N I 4 Zo 5" rl tic . zt ov G ob WI(V Contact Person: E -Mail Address: b ob IA..) F rem 6.71/ 1 .SON • `n n'1 Company Name: Nit .oki■ V 4 Mailing Address: P. 0 . (0c / S6 Contact Person: emote.- Y Lc J. O k el 6 L T E -Mail Address: ti 1 Id A t. MciILi ry s Fri a 0 n► H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh MECHANICAL PERMIT APPLICATION irk Day Telephone: 'ZOb - '396 -974' A 9 Y/3 y City State Zip Fax Number: 'Z 4S ) 7 3 City State Zip Day Telephone: 2 - 3 ' ) 7 V Fax Number: 2 O 6 - 6 f6 r 173j Expiration Date: 3" / b - Z01 D City State Day Telephone: ZO 6" b 2-3 p l Fax Number: 20 b " b 2'3 ' `'I G ZS (4) es 9 g o, 9g /Z� City State Zip Day Telephone: 2- 74 Z Fax Number: 2 0 G — 4S - E3 — 177/ Page 1 of 2 Unit Type: ' Qty Unit Type: Qty Unit Type: , ; Qty ' .Boiler /Compressor: :. • Qty Fumace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM ' Incinerator — Comm/Ind L ) _ �!, J.r`� / Valuation of Project (contractor's bid price): $ 613 t 3 7 Scope of Work (please provide detailed information): (-414 ^' f II 7 ro SQL' F kit ',v,/ Use: Residential: New Commercial: New Fuel Type: Electric Signature: Print Name: Mailing Address: I Date Application Accepted: BUILDING OWNER OR AUTHO D AG Ot-lk(r �cY; Gas ❑ Replacement Replacement Indicate type of mechanical work being installed and the quantity below: 2a.i I go147 .5 D 3ra IN S H :\Applications\Forms- Apphcatmns On Lme\2009 Applications \1.2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Other: Date Application Expires: Date: ‘1 7,06 Day Telephone: •1 L.161-+ y/3 Z / State Zip City LoLoUtloci 39 6 - 76 V Staff Initials: Page 2 of 2 Parcel No.: 1023049069 Permit Number: M09 -036 Address: 3355 S 120 PL TUKW Status: APPROVED Suite No: Applied Date: 04/06/2009 Applicant: KING COUNTY DATA CENTER Issue Date: Receipt No.: R09 -00583 Initials: User ID: Payee: JEM 1165 MCKINSTRY CO SERVICE ACCOUNT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10251 688.19 Authorization No. ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000.322.102.00.0 688.15 000/345.830 .04 Total: $688.19 Payment Amount: $688.19 Payment Date: 04/16/2009 10:09 AM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 04 -16 -2009 Receipt No.: R09 -00530 Initials: User ID: Payee: JEM 1165 ACCOUNT ITEM LIST: Description MCKINSTRY CO. PLAN CHECK - NONRES II City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Check 10233 172.00 Authorization No. TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Parcel No.: 1023049069 Permit Number: M09 -036 Address: 3355 S 120 PL TUKW Status: PENDING Suite No: Applied Date: 04/06/2009 Applicant: KING COUNTY DATA CENTER Issue Date: Account Code Current Pmts 000/345.830 172.00 Total: $172.00 a Payment Amount: $172.00 Payment Date: 04/06/2009 12:02 PM Balance: $688.19 PAYMENT RECEIVED doc: Receiot -06 Printed: 04 -06 -2009 Proj ct!: // Type ofppinppsp�eectio Address. r f r _ � / � Date Called: Special Instructions: Date Wanted: !!l��� J„�a m� S — � � Q / p.m. Requester: Phone No: t4 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit M o 9 -03(e PERMIT NO. CITY OF TUKWILA BUILDING DIVISION-- t2 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 U A pproved per applicable codes. El Corrections required prior to approval. /` COMMENTS: Inspecte 4, Date: as $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: I, / J eat .t/7 Type of Inspection f � S/fo fi t' Address: 335 s /Zo Date Called: ( n 1`- n 04 �ZfR ! Special Instructions: �, __ Date Wanted: a.m Requester: Phone No: a: - 7 ,96 os 5 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. INSPECTION RECORD Retain a copy with permit l �A(6 -036 Corrections required prior to approval. COMMENTS: s (fn A, A-3 of 6Jel ,;•.5„ 14/ -e e 4- Date: 01 E1 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: Type of Inspec ion: . Address: ,�3 ..,-' S 420 1 Date Called: Special Instructions: / Date Wanted: a.m. 5 7- a 7 C_. Requester: P o2 n 0G -7f '' Q,.S'g 5 INSPECTION NO. COMMENTS: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION , P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (tO6)431 -3670 Approved per applicable codes. El Corrections required prior to approval. / Date: S n I ns pect°f: EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: 443 -€ 1 Type of Insp on: Address: it 33 S I TO ft- Date Called: Special Instructions: Date Wanted: q O I O � a.ny p.m. Requester: Phone No: C,La — vY eK MS- o3C° Mn8 -4-3Jo INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 • (206)431 -3670 Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: [Y. -mss► I t). ti Inspect I Date:4 f) J — i)L t ❑ $60.00 REINSPECTION FEE REQUIRED, Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 4 Project ` "� ` K 1 eVG ckj bA T'- Type of I pec r n: _ l'. /c��1°Y'R ' id" 1 \ Addres ` 3 3 5 5 S \Zo Pi— Date Called: Special Instructions: Date Wanted: COP I.1 _ 'z1 -Uc, p.m. Requester: Phone No: / 2.0 �7 � t✓ -e. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT,NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 . 1206)431 -3670 Approved per applicable codes. Corrections required prior to approval. 8 COMMENTS: ( -' � J 6 J f R,A _ / 2 r1 1 r� v S� j .014 rhoki f P At Inspector: AA-cd Date: 4 2 q ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: A Lam. Sprinklers: Fire Alarm: i — Type /1 611 Inspection: J€ c t-/ Address: t 335c Suite #: S, 120 f L. Contact Person: 4 M f AL L.ti. -- Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre- Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT \ lit o� - X 3 (0 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 -575 - 4407 \ 1 Approved per applicable codes. ENTS: Corrections required prior to approval. cr Date: 5/7M r s.. Inspector: 4 1;, PI $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Documents/routing slip.doc 2 -28 -02 ACTIVITY NUMBER: M09 -036 DATE: 04 -06 -09 PROJECT NAME: KING COUNTY DATA CENTER SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEEPARTME u lding Division � t� Public Works Complete Comments: Ni PLAN REVIEW /ROUTING SLIP DETERMINATIgN OF COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: OPERM9T COORD COPY N Fire Prevention Structural Incomplete n Planning Division U Permit Coordinator Not Applicable DUE DATE: 04-07-09 Permit Center.Use Only '. 1 • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS UTING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 05 -05-09 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Name Role Effective Date Expiration Date PEDERSEN, JAMIE D AGENT 03/16/2006 Status ALLEN, DEAN C PARTNER /MEMBER 03/16/2006 GENERAL MOORE, DOUGLAS J PARTNER /MEMBER 03/16/2006 ARCHIVED ALLEN, DAVID E PARTNER /MEMBER 03/16/2006 GENERAL TEPLICKY, JOSEPH PARTNER /MEMBER 03/16/2006 REREGISTERED License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WESTVI*121RF WESTVENT INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 12/6/1988 9/1/1994 ARCHIVED MCKIN* *372ND MCKINSTRY CO CONSTRUCTION CONTRACTOR GENERAL UNUSED 8/20/1963 1 /2/2008 REREGISTERED Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 TRAVELERS CAS Et SURETY CO 104702039 01/03/2006 Until Cancelled $12,000.00 03/16/2006 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L81 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MCKINSTRY CO LLC 2067623311 PO BOX 24567 SEATTLE WA 98134 KING Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602569922 ACTIVE MCKINCL942DW CONSTRUCTION CONTRACTOR 3/16/2006 3/16/2010 GENERAL UNUSED Business Owner Information Bond Information Insurance Information • • Page 1 of 2 https: // fortress .wa.gov /lni/bbip/Detail.aspx 04/16/2009 SHEET NUMBER SHEET TITLE SCALE MO.O DRAWING INDEX, SYMBOLS AND ABBREVIATIONS NONE MO.1 SEQUENCE OF OPERATION & BASIS OF DESIGN NONE MO.2 CONTROL DIAGRAMS NONE MO.3 SEISMIC INFORMATION NONE MO.4 SEISMIC BRACING FOR ACU - FOR REFERNCE ONLY NONE MO.5 SEISMIC BRACING FOR ACU - FOR REFERNCE ONLY NONE M2.2 2RD FLOOR HVAC PLAN 1/32" = 1' -0" M3.2 2RD FLOOR ENLARGED HVAC PLAN 1/8" = 1" -0" M7.0 HVAC SPECIFICATIONS AND EQUIPMENT SCHEDULES NONE c c 10 0 0 \ r i 0 0 0 0 L C 0 a 0 0 c 0 c G c1 0 0 0 10 f 0 G c 0 C s ABBREVIATIONS GENERAL AD ADJ AFF AFG AG AMP ARCH AUTO AUX BD BHP BLDG BOP BOT BS BTU BTUH CA CAB COND C/L CLG CFM CLG CO CO2 COL CONC COND CONN CONSTR CONTR CTL DET DIA DIAG DIM DISCH DIV DN DS DWDI DWG DWV (E EC EL ELEC ELEV EP EQUIP ESP EXH EXIST (F) F FA FCO FDC FDN FIG FIN FIO FLEX FLG FLR FO FP FPM FT FTG FURN GA GALV GC GEN GPM GWB HP HR HS HTG HTR ACCESS DOOR ADJUSTABLE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ABOVE GROUND AMPERE ARCHITECT; ARCHITECTURAL AUTOMATIC AUXILIARY BOARD BRAKE HORSEPOWER BUILDING BOTTOM OF PIPE BOTTOM BIRD SCREEN BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR COMPRESSED AIR CABINET CONDENSATE CENTER LINE CEILING CUBIC FEET PER MINUTE CEILING CARBON MONOXIDE CARBON DIOXIDE COLUMN CONCRETE CONDENSER; CONDENSATE CONNECT; CONNECTION CONSTRUCTION CONTRACTOR CONTROL DETAIL DIAMETER DIAGONAL DIMENSION DISCHARGE DIVISION DOWN DISCONNECT SWITCH; DOOR SWITCH DOUBLE WIDTH, DOUBLE INLET DRAWING DRAIN, WASTE, VENT EXISTING EACH ELECTRICAL CONTACTOR; END CAP ELEVATION ELECTRICAL ELEVATION ELECTRICAL PANEL; END PLUG EQUIPMENT EXTERNAL STATIC PRESSURE EXHAUST EXISTING FUTURE FAHRENHEIT FIRE ALARM FLOOR CLEANOUT FIRE DEPARTMENT CONNECTION FOUNDATION FIGURE FINISH FURNISHED AND INSTALLED BY OWNER FLEXIBLE FLANGE FLOOR FUEL OIL FIRE PROTECTION FEET PER MINUTE FOOT; FEET FOOTING FURNISH GAGE GALVANIZED GENERAL CONTRACTOR GENERATOR GALLONS PER MINUTE GYPSUM WALL BOARD HIGH HORSEPOWER; HIGH PRESSURE HEATING RETURN HEATING SUPPLY HEATING HEATER ID INSIDE DIAMETER /DIMENSION LAB LABORATORY LF LINEAL FOOT MAU MAX MBH MED MEZZ MFR MH MIN MISC MTD N/A NC NEG NIC NO NOM NTS OA OC OD OVHD POC PRELIM PSI PSIG QTY R RAD REQD RPM SECT SF SIM SPEC SQ STD STRUC MAKE —UP AIR UNIT MAXIMUM 1000 BRITISH THERMAL UNITS PER HOUR MEDIUM MEZZANINE MANUFACTURER MANHOLE MINIMUM; MINUTE(S) MISCELLANEOUS MOUNTED NOT APPLICABLE NORMALLY CLOSED NEGATIVE NOT IN CONTRACT NORMALLY OPEN; NUMBER NOMINAL NOT TO SCALE OVERALL ON CENTER OUTSIDE DIAMETER OVERHEAD POINT OF CONNECTION PRELIMINARY POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE QUANTITY RELOCATED RADIUS REQUIRED REVOLUTIONS PER MINUTE SECTION SQUARE FOOT SIMILAR SPECIFICATION SQUARE STANDARD STRUCTURAL TBD TI TOC TOS TYP UG UNO VAV VD VER VFD VSD W/ WITH W/O WITHOUT HVAC AC ACT AHU BDD BOD CC CRU CT CV DB DIFF DMPR EA EAT ECG EF FCU FD FM FP FTU HC HR HVAC RA RAT RCP RTU SA SAT SD SF S /FD SL SLSM SM SP TDH TG TOD TSP WB WC WG DCW DHW DHWC DSP CD CHW CHR CHS CT EWT FHV LWT TOP TO BE DETERMINED TENANT IMPROVEMENTS TOP OF CONCRETE TOP OF STEEL TYPICAL PLUMBING AD AREA DRAIN UNDERGROUND UNLESS NOTED OTHERWISE VARIABLE AIR VOLUME VOLUME DAMPER VERIFY VARIABLE FREQUENCY DRIVE VARIABLE SPEED DRIVE AIR CONDITIONING ACOUSTICAL CEILING TILE AIR HANDLING UNIT BACKDRAFT DAMPER BOTTOM OF DUCT COOLING COIL COMPUTER ROOM UNIT COOLING TOWER CONSTANT VOLUME DRY BULB DIFFUSER DAMPER EXHAUST AIR ENTERING AIR TEMPERATURE EGGCRATE GRILLE EXHAUST FAN FAN COIL UNIT FIRE DAMPER FREQUENCY MODULATION FIRE PROTECTION; FAN POWERED FAN TERMINAL UNIT GRD GRILLE, REGISTER, DIFFUSER HEATING COIL HEATING RETURN HEATING, VENTILATION AND AIR CONDITIONING LAT LEAVING AIR TEMPERATURE LD LINEAR DIFFUSER MC MECHANICAL CONTRACTOR MECH MECHANICAL MOD MOTOR OPERATED DAMPER; MODULATING MUA MAKE UP AIR OA OVERALL; OUTSIDE AIR OBD OPPOSED BLADE DAMPER RETURN AIR RETURN AIR TEMPERATURE REFLECTED CEILING PLAN ROOF TOP UNIT SUPPLY AIR SUPPLY AIR TEMPERATURE SMOKE DAMPER SUPPLY FAN SMOKE FIRE DAMPER SOUND LINED SOUND LINED SHEET METAL SHEET METAL STATIC PRESSURE TOTAL DYNAMIC HEAD TRANSFER GRILLE TOP OF DUCT TOTAL STATIC PRESSURE UH UNIT HEATER WET BULB WATER COLUMN WATER GAUGE CO CLEAN OUT; CARBON MONOXIDE DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC HOT WATER RECIRCULATION DRY STANDPIPE EWC ELECTRICAL WATER COOLER FD FLOOR DRAIN IE INVERT ELEVATION IN WC INCHES WATER COLUMN IW IONIZED WATER; INDIRECT WASTE NPCW NON POTABLE COLD WATER ORL OVERFLOW RAINWATER LEADER PD PLANTER DRAIN; PRESSURE DROP PERF PERFORATED PLBG PLUMBING PRV PRESSURE REDUCING VALVE RPBP REDUCED PRESSURE BACKFLOW PREVENTER SD STORM DRAIN SS SANITARY SEWER VTR VENT THROUGH ROOF W WASTE WC WATER CLOSET WH WATER HEATER WSP WET STANDPIPE PIPING BP BACKFLOW PREVENTER CONDENSATE DRAIN CHILLED WATER CHILLED WATER RETURN CHILLED WATER SUPPLY CONICAL TEE ENTERING WATER TEMPERATURE FIRE HOSE VALVE LEAVING WATER TEMPERATURE TOP OF PIPE PIPING IDENTIFICATION HVAC A COND — — — — —CDR— CDS CHS —CHR— HR G HS RL ® RS ST PLUMBING FIRE PROTECTION FW WSP PIPING FITTINGS 1% -t 1 rs IT9 VALVES GRW GAW ID IRR NP ORL PW PSD RWL RWL SD - SS - UD —V— W — w — DSP FDC F FP ItI I0I PIPING ACCESSORIES 271 4AV 4 HAV RPBP O a 0 ID nnnnnnnTnnnn' WAI IS LF 1 A COND CDR CDS CHS CHR HR HS RL RS ST CW GRW GAW HW HWC ID IRR NPCW ORL PW PSD RWL RWL SD SS UD V W W DSP FDC F FP FW WSP COMPRESSED AIR PIPE CONDENSATE DRAIN PIPE CONDENSER WATER RETURN PIPE CONDENSER WATER SUPPLY PIPE CHILLED WATER SUPPLY PIPE CHILLED WATER RETURN PIPE NATURAL GAS PIPE HEATING WATER RETURN PIPE HEATING WATER SUPPLY PIPE REFRIGERANT LIQUID PIPE REFRIGERANT SUCTION PIPE STEAM SUPPLY COLD WATER PIPE (POTABLE) GREASE WASTE GARAGE WASTE HOT WATER PIPE (POTABLE) HOT WATER CIRCULATING (POTABLE) INDIRECT DRAIN IRRIGATION WATER PIPE NON POTABLE CW PIPE OVERFLOW RAINWATER LEADER PUMPED WASTE PUMPED STORM DRAIN RAINWATER LEADER BELOW GRADE RAINWATER LEADER STORM DRAIN PIPE SANITARY SEWER PIPE (SITE) UNDERDRAIN PIPE VENT PIPE (SANITARY) WASTE PIPE WASTE PIPE BELOW GROUND DRY STAND PIPE FIRE DEPT. CONNECTION PIPE FIRE SPRINKLER PIPE FIRE PROTECTION WATER PIPE FIRE PROTECTION WASTE PIPE WET STAND PIPE TEE W /PIPE UP TEE DOWN W /ELBOW TEE UP W/ ELBOW TEE UP TEE DOWN 90' ELBOW UP 90' ELBOW DN CAP UNION FLANGE FLEX HOSE CONNECTION DOUBLE BELLOWS FLEX CONNECTION SINGLE BELLOWS FLEX CONNECTION FLOW ARROW CONCENTRIC REDUCER ECCENTRIC REDUCER SLOPE SYMBOL BREAK OR CONTNUATION SYMBOL DOWN SPOUT NOZZLE CLEANOUT 45 ELBOW 45 ELBOW 90' ELBOW 90' ELBOW CROSS TEE WYE TAP HOSE CONNECTION MOTORIZED 2 —WAY VALVE MOTORIZED 3 —WAY VALVE PRESSURE REDUCING VALVE CONTROL VALVE RELIEF VALVE BALL VALVE 3 —WAY GATE VALVE BUTTERFLY VALVE DIAPHRAGM VAVLE CHECK VALVE NEEDLE VALVE GLOBE VALVE GLOBE VALVE ANGLE GLOBE VALVE 3 —WAY GATE PLUG VALVE BALANCING VALVE HOSE BIBB PUMP MANUAL AIR VENT AUTOMATIC AIR VENT HIGH CAPACITY AIR VENT SHOCK ARRESTOR FLOW SWITCH VACUUM BREAKER PRESSURE GAUGE TEMPERATURE SENSOR TEMPERATURE INDICATOR AUTO FLOW VALVE FLOW METER Y STRAINER Y STRAINER W/ BALL VALVE PIPE SLEEVE STEAM TRAP PETES PLUG HEAT TRACING SUCTION DIFFUSER W/ STRAINER REDUCED PRESSURE BACKFLOW PREVENTOR FUNNEL DRAIN FLOOR DRAIN ROOF DRAIN ROOF OVERFLOW DRAIN DUCTWORK ACCESSORIES J L A D J AD 12x12 SL 12x12 2 "SL — R co DUCTWORK RECTANGULAR DUCT RECTANGULAR DUCT I x RECTANGULAR DUCT RECTANGULAR DUCT 1 / EDD THERMOSTAT SENSOR BIRDSCREEN OR SCREENED OPENING SUPPLY GRILLE RETURN OR EXHAUST GRILLE VOLUME DAMPER MOTOR OPERATED DAMPER AIRFLOW MONITOR REMOTELY OPERATED VOLUME DAMPER (YOUNG REGULATOR OR APPROVED) BACK DRAFT DAMPER COORDINATE WITH CEILING APPURTENANCES. FLEX CONNECTION FIRE DAMPER THROUGH WALL FIRE DAMPER THROUGH FLOOR FIRE /SMOKE DAMPER THROUGH WALL FIRE /SMOKE DAMPER THROUGH FLOOR ACCESS DOORS 1" ACOUSTICALLY LINED DUCT 2" ACOUSTICALLY LINED DUCT CHANGE OF ELEVATION RISE(R) DROP(D) TRANSITION TURNING VANES SMOKE DETECTOR RETURN / EXHAUST / OUTSIDE AIR SUPPLY / TRANSFER AIR TERMINAL UNITS — SEE SCHEDULE FOR TYPE SUPPLY AIR DUCT TURNING UP OR TOWARD SUPPLY AIR DUCT TURNING DOWN OR AWAY EXHAUST OR RETURN AIR DUCT TURNING UP OR TOWARD EXHAUST OR RETURN AIR DUCT TURNING DOWN OR AWAY ROUND DUCT TURNING UP OR TOWARD ROUND DUCT TURNING DOWN OR AWAY OVAL DUCT TURNING UP OR TOWARD OVAL DUCT TURNING DOWN OR AWAY W FLEXIBLE DUCT INSTRUMENTATION AND CONTROLS CARBON MONOXIDE SENSOR VISUAL ALARM LIGHT — WALL MOUNTED GRILLE /REGISTER/DIFFUSER DOUBLE LINE X x 1 HVAC - ANNOTATION VAV BOX TAG 1 -23 S— C8 -09 —A 000 000 S-- C8 --09 —A 1 DUCT WORK EQUIPMENT TAG LOUVER TAG LEGAL DESCRIPTION CEILING SUPPLY AIR DIFFUSER —► CEILING SUPPLY AIR DIFFUSER (SHOWN WITH THROW ARROWS) 1 B1 -1 CEILING RETURN, EXHAUST OR TRANSFER AIR GRILLE LINEAR DIFFUSER (CEILING) LINEAR DIFFUSER (WALL) LOUVER PLAN VIEW LOUVER (ELEVATION VIEW) 0 ROUND DUCT SYMBOL -e- FLAT OVAL DUCT SYMBOL EF -2 -1 -- CONSECUTIVE EQUIP. # FLOOR OF EQUIP. LOCATION EQUIPMENT DESIGNATION GRILLE, REGISTER, OR DIFFUSER TAG DT5-615 CFM EACH 1 SIZE TYPE CODE FLOOR # — DISCRETE BOX # SEE BELOW PRIMARY CFM FAN CFM ACOUSTICAL ACCESSORIES (IF REQ'D) KW OF AUX. HEAT. VAV BOX SIZE; SEE SCHED. SERIES FAN FAN O POWERED O BOX S) (P) EQUIPMENT TAG LD5 /3 -300 LINEAR DIFFUSER GRILLE CFM EACH ACTIVE LENGTH IN FT. TOTAL LENGTH IN FT. TYPE CODE LOUVER TAG I-- CONSECUTIVE LOUVER #. FLOOR LOCATED FACADE DESIGNATION B — BANK M MUSEUM NE 1/4 OF THE SE 1/4 AND SE 1/4 OF THE SE 1/4 OF SECTION 9 AND GOV'T LOT 15 AND SW 1 /4 OF THE SW 1/4 OF SECTION 10, T23N., R4E., W.M. CITY OF TUKWILA, KING COUNTY, WASHINGTON. LOCATION / SITE MAP iu'I I;1 1111 III II II �Iu1I iI lii 1[1111' �kl n"�iil ulll 1 1 01 mi111 1 11411 II I , ] 111u1111141 1 111'IuI, I1I1�lil l VII 1. '1 16E1 1111111111111 ill 1 11 1 II IIIIIINI4 1111 1 111111 11 1111 ° ' i lnuul VI IV I I 1 11VIP Iu uI I I'. �,� I Ih14,l[uI ll [ i r1'�11'hV d f� REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. DRAWING INDEX GENERAL INFORMATION SYMBOLS XXXXXXXxxxxx DEMO MECHANICAL WORK ED L �- -J GENERAL NOTES: 0 PLAN NUMBER MATCHLINE 1. VERIFY LOCATIONS AND DIMENSIONS OF ALL EQUIPMENT AND COORDINATE ALL WORK PRIOR TO START OF CONSTRUCTION. 2. OBTAIN APPROVAL OF STRUCTURAL ENGINEER PRIOR TO INSTALLATION OF PENETRATIONS NOT PREVIOUSLY COORDINATED OR AGREED UPON, I.E. ANCHOR BOLT DEPTHS, ETC. 3. CONCRETE EQUIPMENT CURBS, PIPING RAT SLABS, SUMP BASINS, AND HOUSEKEEPING PADS ARE SHOWN FOR APPROXIMATE LOCATION AND SIZE AND ARE TO BE PROVIDED BY THE GENERAL CONTRACTOR. WHERE PROVIDED, REFER TO STRUCTURAL INFO FOR ADDITIONAL DETAILS. 4. COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS: SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION NEW MECHANICAL WORK FUTURE TI SCOPE & NEW WORK OTHER THAN MECHANICAL DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL /DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN SHEET NUMBER WHERE, PLAN SHOWN REVISION NUMBER — DENOTES NUMBER AND DATE WHEN REVISION OR ISSUE OCCURED REVISION CLOUD — DENOTES AREA OF CHANGE DETAIL REFERENCE OUTLINE WITH NUMBER AND SHEET LOCATION PLUMBING FIXTURE CALL —OUT (SEE PLUMBING SCHEDULES) DRAWING NOTE REFERENCE POINT OF CONNECTION CENTERLINE STRUCTURAL BEAM PENETRATION (SEE M503) STRUCTURAL BEAM HAUNCH (SEE M503) A. PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO THE OWNER (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.4.3) B. PROVIDE TO THE OWNER ALL NECESSARY SYSTEM OPERATION AND MAINTENANCE MANUALS (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.4.2) C. BALANCE ALL HVAC SYSTEMS AND PROVIDE TO THE OWNER A WRITTEN BALANCING REPORT (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.2.1) D. EQUIPMENT /SYSTEMS TESTING SHALL BE PERFORMED IN ACCORDANCE WITH APPROVED PLANS (PER 2006 WASHINGTON STATE ENERGY CODE SL(TION 1416.2.3.1). E. TEST, CALIBRATE AND ADJUST ALL HVAC CO TROLS AND SEQUENCES OF OPERATION IN ACCORDANCE WITH THE APPROVED PLANS (PETE -2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.3.2), NECESSARY TESTS ARE IDENTIFIED IN 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.3.1; PREPARE A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.5.1); PROVIDE TO THE OWNER A FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.5.2). 5. PERFORMANCE OF ALL NEW BUILDING MECHANICAL SYSTEMS WILL COMPLY WITH OR EXCEED THE MINIMUM REQUIREMENTS AS SET FORTH IN THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1410 - GENERAL REQUIREMENTS. 6. MINIMUM VENTILATION QUANTITIES WILL COMPLY WITH OR EXCEED THE 2006 INTERNATIONAL MECHANICAL CODE. 7. ALL MOTORS WILL COMPLY WITH CHAPTER 15 OF THE 2006 WASHINGTON STATE ENERGY CODE. FOR ADDITIONAL DETAILS, SEE EQUIPMENT SCHEDULES CONTAINED WITHIN THIS DRAWING SET. 8. ALL SYSTEMS WILL BE INSULATED AS PRESCRIBED IN CHAPTER 14, TABLE 145 OF THE 2006 WASHINGTON STATE ENERGY CODE. FOR ADDITIONAL DETAILS, SEE DUCTWORK AND PIPING SPECIFICATION MATRICES CONTAINED WITHIN THIS DRAWING SET. 9. VERIFY THAT ALL NECESSARY INFORMATION HAS BEEN PROVIDED PRIOR TO CONNECTION OF EQUIPMENT FURNISHED BY THE OWNER OR OTHERS. 10.FOR ADDITIONAL SYSTEM AND EQUIPMENT SEISMIC REQUIREMENTS, REFER TO STRUCTURAL INFORMATION (WHERE PROVIDED) AND PROJECT SPECIFIC SEISMIC DESIGN INFORMATION SHEET CONTAINED WITHIN THIS DRAWING SET. CODE COMPLIANCE AP PROVED APR 1 2009 City of 'J /11a FILE COPY Permit No. Plan review approval is subject to errors and omission. Approval of construction documents does not authorize the violation of any adopted code or ordinance, Receipt of approved Field • py and conditions is acknowledged: City Of lbkwi'a BUILDING DIVISION M RECEIVED CITY OF TUKWILA APR 0 6 2009 PERMIT CENTER a 1- 11 0 0 z c•i CV (0 CL 2 0 H (1) W uJ C 0 Z ISSUED / REVISED PERMIT SET DRAWING INDEX, SYMBOLS, AND ABBREVIATIONS 0 0 LL L 0 u_ EXPIRES: 9-21-09 a) co a) instr e Of Your Building SEATTLE: 5005 3RD AVENUE 5 PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503 -331 -0234 www.mckinstry.com DATE 3/31/09 Q '- E 9 Lc) r` co cm N a) CO C) t2 cv CN (D (0 0 N 1-- LL PRINT ROOM Heat Gain KW Heat Gain BTU Temp. Requirement R.H. Requirement Total 10,000SF Suite (Including Future) 1500 5119000 60-78°F 30-70% Future Buildout Space 420 1433040 60-78°F 30-70% . , - , , . - : , :- • • ,7 . 4 Printer Room 11 38000 66-74°F 35-55% . . , 1 • Storage/Build Room 3 10200 66-74°F N/A Current Server/Legend Equip Room/MDF 1055 3602240 60-78°F 30-70% PRINT ROOM AREA 960 SF PRINT EQUIP 11.1 KW PEOPLE (4) .5 KW LIGHTING .96 KW ENVELOPE (225SF WALL AREA) .2 KW 72 °F ROOM SETPOINT TEMP 70 °F SUPPLY TEMP 55 °F SUPPLY AIR PROVIDED 2690 CFM OFFICE AREA 80 SF EQUIPMENT .08 KW PEOPLE (2) .26 KW LIGHTING .08 KW 61 °F ROOM SETPOINT TEMP 72 °F SUPPLY TEMP 61 °F SUPPLY AIR PROVIDED 121 CFM STORAGE/BUILD ROOM AREA 380 SF EQUIPMENT .6 KW PEOPLE (3) .4 KW LIGHTING .38 KW 61 °F ROOM SETPOINT TEMP 70 °F SUPPLY TEMP 61 °F SUPPLY AIR PROVIDED 470 CFM NETWORK OPERATION CENTER AREA 400 SF TOTAL SPACE COOLING REQUIREMENT 10 KW ROOM SETPOINT TEMP 74 °F SUPPLY TEMP 61 °F SUPPLY AIR PROVIDED 2419 CFM Project: Sabey SDC5201 — King Count Sut Item: Sequence Of Operations DeF,Ign Criteria; 72°F temperature and 30-70% Relative Humidity in floor epic Ro conditions: The controller will contrt:Ilto maintain supply air temperature and static pressure to the space continuously. Si gly QfflecrIptiore Supply air Is provided to the space from the Central Plant air handling equipment located on the 3 Floor, The duct mounted - Dow measuring device will monitor the airliovie Room differential pressurization (between the data 'floor spaoe and the corridor) module the damper in the supply duetweork to maintain room differential pressure setpoint. The (5) room temperature sensors U be utilized to modulate the return air damper to maintain the room temperature setpoint of 72"F (adj,). rf Suite: The airflow monitoring station shall modulate the suppl'yr air damper (Py100-5201-1) to rIrtdfr1 maximum supply airflow tc,i tho spaee. Alarms wilt be provided as follows: Airflow Failure: The tneaeured airflow Is below the alarm setpoInt (adj.). The controller will monitor (5) ,space temperature humidity sensors In the Suite, The sensors are wail mounted sensors and wilt be Installed at Owner designoted locations. T ontroller will 'utilize the Bensors by an operator selected method for specie controller. Modes: • Average of all (5) sensors ▪ Highest temperature of all (5) sensors • individual Sensor Seleotion (Le, Sensor #1, Sensor #2, etc.) If a sensor has failed (i.e, sensor value reflecting 5ensor failure), the eontroller viII remove it frorn the averaging calculation. if the failed sensor is being utJJized for space control, the controller wili utilize an average of the remaining seneors, Alarms will be provided as foilows: • a. Sueoly. Air TemPerettire Setppint :I fEtx,edj. The controiier will monitor the supply air temperature and 1;vill maintain El fixed supply air temperature setpoint of 72"F (adj.), The Controllor MI modulate the return air damper (from Suite) to maintain the supply air temperature to the Suite. Alarres vviii be provided as follows: • High Supply Air Temp: if the supply air temperature is 5"F (adj.) greater than setpoint. Space Pressure Saboy: SE)C5201 Page 1 of 3 * "Pre-Alarrn.": Alarm level preset by Ovonerlinstaiiing Contractor. * Alerm": Alarm level preset by °wrier/installing Contraetor. The controls sy.stern vr modulate control dampers as per the sequence shown on the control drarkvings., The BS .system is a ,monitoring system only, and can not reset alarm condition ,s or re- 'onfigure alarm levels in 'il.ESDA units„ Printer ROOM; Com u Roo nit ACU-5201 System runs continuously. Zone room temperature and humidity sensor shall reset unit eontrol setpoint to modulate supply air temperature and humidity to maintain sper...e temperature between 66 and 74 with r elative humidity between 35 and 55 percent, Inlet damper control shall minimize enthaipy into the ACU by maculating supply air end ceiling Extraust,EwX__°F-1 5'201-1: System runs continuously Variable frequency shall moduiate fan motor apeed to maintain a 0,05" negative pressure in the printer room. 52Apke E F A hardwired smoke detector interrupt 9 ar operation upon detection of smoke in the exhaust duct, Offiqe/NIOri toraae: Moduiate terminal damper to satisfy room Sensor setpoint. Upon need for heat modulate the control damper closed to minimum positioei until sensor setpoint is satisfied. Sabey: 3Da201 Sensor #X Failure: The sensor is outside of acceptable operating conditions. Sensor #X High Temperature: The space temperature is greater than 76"F (adj.). Sensor #X Low Temperature: The pace temperature is below 66uF (adj.) Sensor #X High Humidity:, The space humidity Is greater than the 70 (adj,), Sensor #X, Low Humidity: The space humidity is below the 30%RH , (adj.). f 11-03-08 SCOPE OF WORK FOR THIS PERMTT. ALL OTHER WORK COVERED UNDER PERMIT #M08-264 Rage 3 of 5 1•4.13-06 Tho controiler will measure spare Static pressure between the space and the common corridor. The controller will modulute tl eeppiy damper to maintain a positive space static pressure setpolnt of 0,06In H (adj. range 0,025" to 0,101 Airerrtis be provided as folloWS Low Static Pressure: If the S pale pressure , drops below the setpoint. If there is a loss of acceptable pressure reading, the controller will maintain last cornmand signal and initiate an alarm. Jrri Farts (RE E,3,, 5201C & RF-5201 Each fan runs continuously. One an Is redundant. Return Air Description: The rack mounted eervers in the floor space are equipped 'with plenums the route the hot air from the server to the ceiling plenum. Differential pressure senors between the room and ceiling plenum ],v111 modulate the return fan VFDs to maintain Fi negative pressure setpoire of -0.01 in 4 (adj, range 0,0'' to -0.10), Fun Condttons The oontroller ieellIcommand the (4) return fens to operate run oontInuously. Upon El leSe Of control signel, the return fan iv'F'D controller erill continue to run fan at Its pre-set minimum speed, The eontroliar will have Independent operating modes for eaoh fan to allovA unit shutdown for maintenance, Hen Motile: * Ealen return hIn and associated isolation damper vill be staged upon initial start-up. • The controller ivi command the return fan isolation damper to open, • After a timed duration, the controller will command the return h.ln to run, • The controller Will monitor run status of the VFD and disable the fan If status is not confirmed, The Isolation damper will be closed ' the controller disables the fan, • The isolation damper open Lipari a controller failure or loss of 24vee noviAer. • "The gontroller],e111,send the same control sigriel to each of the return fan VFDs maintain ceiling plenum setpoint, Smoke Detectors in Fans: A hardvitlred smoke detector wili Interrupt the ten operation upon detection of en pike in the return duct, Pressure Sensors: The curtailer will averege the (2) ceiling pressure sensors for control. If there Is a loss of acceptable pressure reedirig, the controller remove the sensor from the control calculations, and r iF lerm. Alarms will be provided as follows: O Low Pressure: If ceiling plenum pressure is greater than 0.0in H RItfLEXh Run K'ode : The controller v U maintain a return duct static pressure setpoint of 0.5In H (adj,) by modulating the exhaust air damper (to the outeide), A duct static pressure sensor in the return duetwork downstream of the return fans Mil provide the control signal, :],/„Eft1.2,e,s in Suite: Description: Tihe VESDA systen1 is an eerly l d'„ P arn[ng smoke detection system that monitors the air for smoke contaminants, There (2) self contained control panels +Avith remote airflow pickup (1 for the supply air to the Suite end 1 for the exiting air from the Suite). Each panel provides 3 levels of smoke detection, The 1 rind 2 levels are 'fault conditions end wIJ be monitored by the control system and visually checked by the Owner (Alarms are wired in serial to the ALC control system), The 3" lievei is a monitored elerre condition (Alarm at each panel is " rod in series to the ,i control system). Alarms will be provided as follows: • 'Fault': Alarm level preset by Owner/installing Contractor. Sabey SOC20 PORe 2 of 3 11-03-08 !NI LE, NIA Regards, Bul DittLigett, Senor Engineer to DI Your Uulid 2008 4 3582( 'In John Ford Sabey Company 12201Tukwila inteeTtationeL B Ivd . ra Sitington iNease if youhave auyqttetio. Oetobe • S LIBJEC.7.: Sabey 5201 Server ifot An f)itu1iitiii John: 'We bave been asked to recap the decision to change the Suite 5201 f heat As you know whert McKinstry the development of the -suite codling we were, utilizing a 1".1.0t iBle separation that was a custom built endestee with field built,up controls to capture the heat from the serve:r fan diseharges. The earrent design utd•iz.es factory tyuilt en_131091lreS that are a newer product that has been desigted 'for the sarneporpose as: the custom built enclosures without having the large investrn of detaifing.and fieki manu Net:Urn:1g thine of the custom eneldsures,'The manufactuted enclosures aro sihtly more expensive to purchase but make-up the expense by fasterinstallation.: . rChatswotth, tl e. server cabinet, manufactareis one of the leaders in server cabinet industry. - We . are confident that there is not any decrease in pc:ran:mance of the cooling system because of the • changein type of heat capture system fin this projeet, King County Space Requirements SERVER SUITE LOAD CALCULATION DESCRIPTION Supply air is delivered to the suite from a common manifold at Level 3. The supply air is mixed with retum air that has cooled the servers and along with the server heat the air is passed into the ceiling plenum. The retum air to the suite (mixed with the supply air) is modulated to control server room supply air temperature. The the majority of the air is delivered to the space over the Legacy equipment. The large volume of air is heated slightly as it passes over the equipment. The air then flows to individual racks, passes through the servers into the chimneys mounted at the backs of the server racks and is passed into the ceiling plenum. This air is then either mixed at the suite level or returned to the 3rd floor air handler or exhausted to the outside of the building. This is dependent on the outdoor thermal conditions. COOLING SERVERS AT 20°F TEMP RISE THRU SERVERS, ALL SENSIBLE HEAT *256800 BTUH (75KW) 2009 BUILD OUT PER 10/10/08 SPREADSHEET PROVIDED BY KC *1,050 KW TOTAL BUILD OUT PER LEASE AGREEMENT LEGACY EQUIPMENT HEAT GAIN 15 KW (51,300 BTUH) QUANTITY OF AIR SUPPLIED AT LEGACY EQUIP 92,800 CFM DELTA T AT DUE TO LEGACY EQUIP 0.509 °F (NOTE: SUPPLY AIR TEMP TO SERVERS AROUND LEGACY EQUIP MAY BE 0.787°F HIGHER) MDF EQUIPMENT HEAT GAIN QUANTITY OF AIR SUPPLIED AT LEGACY EQUIP DELTA T DUE TO LEGACY EQUIP TOTAL SPACE FINAL BUILDOUT EQUIPMENT LOAD: 1.05 MW SERVER SUITE COOLING LOAD (SEE SUPPORTING LOAD CALCS) TOTAL SPACE FINAL BUILD OUT EQUIP LOAD NETWORK OP CENTER PRINTER ROOM STORAGE/BUILD ROOM OFFICE TOTAL LOAD AVAILABLE FOR SERVERS/MDF COOLING AIRFLOW AT 20°F DELTA T. 56.7 KW (193,460 BTUH) 67,100 CFM 2.66 °F 1050000 (-10000) (-12200) (-1380) (-420) 1026000 WATTS OR 3,501,700 BTUH KING COUNTY EXPANSION SPACE AREA MAX SERVER LOAD 3834 SF 450 KW NOTES 1) SUPPLY AIR TO EQUIPMENT SURROUNDING LEGACY POSSIBLY 0.8°F HIGHER 2) ASSUMED 25OBTU/PER SENSIBLE AND 200BTU/PER LATENT FOR PEOPLE LOAD 3) ASSUMED 1W/SF FOR LIGHTING LOAD 4) ASSUMED 1.5W/SF FOR EQUIPMENT LOAD 5) ±3 °F 6) ASSUMED U=0.15 FOR WALL SCOPE OF WORK FOR THIS PERMIT. ALL OTHER WORK COVERED UNDER PERMIT #1A08-264 SCOPE OF WORK FOR THIS PERMIT. ALL OTHER WORK COVERED UNDER PERMIT #M08-264 M oq o3 ? - TET;fil5iE6Fori Cac)E COMPLIANCE A PPROV ED APR 1 4 2009 1 City of Tukwila ! RECEIVED CITY OF TUKWILA APR 0 6 2009 PERMIT CENTER z 0 0 0 0 a co or Th c— c) (.1 w-- EXPIRES: 9-21-09 ISSUED / REVISED PERMIT SET SEQUENCE OF OPERATION & BASIS OF DESIGN 0 0 0 LL. 1. 0 oc) co a) a) 0 E Q LO 0 N0) 00 0) 0 c0 o0 _c) CN CN cf) co co c\1 c\1 L.L. linty e Of Your Marling SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503-331-0234 1 www.mckinstry.com DATE 3/31/09 VFD =. )4 1'— COOLING COIL 1 AIR FILTER , . = EVAPORATOR 1 1 �. VFD 1 COOLING COIL 1-iI41 '=. X11 'ORATOR 1 1 �. 100 ONI1 FILTER VFD 1 COOLING COIL AIR FILTER '=. X11 EVAPORATOR 1 1 �. 00 ONI MOD- 5201 -11 HUMIDISTAT RETURN AIR FROM PLENUM MOD- 5201 -12 ROOM TEMP. SENSOR ACU-5201 -1A 2,800 CFM SUPPLY MANIFOLD 1 MO.2 NOT TO SCALE SCOPE OF WORK FOR THIS PERMIT, ALL OTHER WORK COVERED UNDER PERMIT jiM08 -264 1 EF -5201 -1 PRINTER ROOM CONTROL DIAGRAM 9 VFD MOD- 5201 -10 1 FM I FUTURE 46,000 CFM 154,000 CFM SPACE TEMP DUCT STATIC SENSOR PRESSURE SPACE SENSOR HUMIDISTAT FLOW METER MOD -5201 -1] PA IMOD-5201 5,835 CFM TO OFFICE /PRINT RM 5201 FUTURE 5202 00 5203 59,150 CFM EXIST SUPPLY AIR ISOLATION DAMPER (TYPICAL)_ EXISTING SUPPLY AIR MANIFOLD 33,650 CFM IMOD-5201 -3 1 M (MOD -5201 -41 > PA y 42,750 CFM 24,350 CFM BY —PASS DMPR 2 TYP EA AHU 2 TYP EACH AHU NOT TO SCALE 2> SA :;› 92,800 CFM SA 67,100 CFM 3 —WAY CONTROL VA. 2 TYP EA AHU EXISTING AHU 52A1 FUTURE EXISTING AHU 52B1 AHU 5201 FUTURE & AHU 5201 SERVER ROOM EXISTING AHU 52A2 AHU 5202 RA 159,900 CFM DATA CENTER SDC 5201 SCHEMATIC CONTROL DIAGRAM OSA DMPR, 2 TYP EA. AHU r RETURN AIR DMPR 12 —TYP RETURN AIR ISOLATION DAMPER (TYPICAL) 5201 7 -EXISTING RETURN AIR MANIFOLD FUTURE 5202 1 5203 RA MOD -5201 -5 MOD -5201 -6 Li 3,035 CFM FUTURE FROM OFFICE 46,000 CFM IMOD-5201 0 I Q L� MOD-5201 -7] MOD -5201 J >,s ,; 1 2009 MO9O3' • FOR — 'LANCE kwll -; DIVISION! RECEIVED CITY OF TUKWILA APR 0 6 2009 PERMIT CENTER EXPIRES: 9 -21 -09 ISSUED / REVISED DATE PERMIT SET CONTROL DIAGRAMS MO.2 cu Z c 0 . ° 4 N I' c� r aL LO W W CO © c (D d oC) C N-- E c� 0 L0 0 IZ— (n N cr)ci C a d co 0) 0 .c 0 N 0 n co co n (1 NN c LU r ..... y+ co (D u) GO o C) CD ..t N : ANN (v 0 to T u cn I LL instry e Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503 -331 -0234 www.mckinstry.com E 0 Z O c 1 J 0 4 0 3/31/09 CALLISON RF-5201 -A 1 'ORATOR 00 ONI FILTER MOD- 5201 -11 HUMIDISTAT RETURN AIR FROM PLENUM MOD- 5201 -12 ROOM TEMP. SENSOR ACU-5201 -1A 2,800 CFM SUPPLY MANIFOLD 1 MO.2 NOT TO SCALE SCOPE OF WORK FOR THIS PERMIT, ALL OTHER WORK COVERED UNDER PERMIT jiM08 -264 1 EF -5201 -1 PRINTER ROOM CONTROL DIAGRAM 9 VFD MOD- 5201 -10 1 FM I FUTURE 46,000 CFM 154,000 CFM SPACE TEMP DUCT STATIC SENSOR PRESSURE SPACE SENSOR HUMIDISTAT FLOW METER MOD -5201 -1] PA IMOD-5201 5,835 CFM TO OFFICE /PRINT RM 5201 FUTURE 5202 00 5203 59,150 CFM EXIST SUPPLY AIR ISOLATION DAMPER (TYPICAL)_ EXISTING SUPPLY AIR MANIFOLD 33,650 CFM IMOD-5201 -3 1 M (MOD -5201 -41 > PA y 42,750 CFM 24,350 CFM BY —PASS DMPR 2 TYP EA AHU 2 TYP EACH AHU NOT TO SCALE 2> SA :;› 92,800 CFM SA 67,100 CFM 3 —WAY CONTROL VA. 2 TYP EA AHU EXISTING AHU 52A1 FUTURE EXISTING AHU 52B1 AHU 5201 FUTURE & AHU 5201 SERVER ROOM EXISTING AHU 52A2 AHU 5202 RA 159,900 CFM DATA CENTER SDC 5201 SCHEMATIC CONTROL DIAGRAM OSA DMPR, 2 TYP EA. AHU r RETURN AIR DMPR 12 —TYP RETURN AIR ISOLATION DAMPER (TYPICAL) 5201 7 -EXISTING RETURN AIR MANIFOLD FUTURE 5202 1 5203 RA MOD -5201 -5 MOD -5201 -6 Li 3,035 CFM FUTURE FROM OFFICE 46,000 CFM IMOD-5201 0 I Q L� MOD-5201 -7] MOD -5201 J >,s ,; 1 2009 MO9O3' • FOR — 'LANCE kwll -; DIVISION! RECEIVED CITY OF TUKWILA APR 0 6 2009 PERMIT CENTER EXPIRES: 9 -21 -09 ISSUED / REVISED DATE PERMIT SET CONTROL DIAGRAMS MO.2 cu Z c 0 . ° 4 N I' c� r aL LO W W CO © c (D d oC) C N-- E c� 0 L0 0 IZ— (n N cr)ci C a d co 0) 0 .c 0 N 0 n co co n (1 NN c LU r ..... y+ co (D u) GO o C) CD ..t N : ANN (v 0 to T u cn I LL instry e Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503 -331 -0234 www.mckinstry.com E 0 Z O c 1 J 0 4 0 3/31/09 CALLISON RF-5201 -A MECHANICAL, PIPING, AND PLUMBING IMPORTANCE FACTOR TABLE COMPONENT DESCRIPTION STANDARD COMPONENT IP =1.0 CRITICAL COMPONENT IP =1.5 NOTES: HVAC - SHEETMETAL/EQUIPMENT g Load g Load, with Exp. Anchors HVAC SUPPLY - MEDIUM PRESSURE .26 g X .39 g HVAC SUPPLY - LOW PRESSURE Level 2 Ceiling X .44 g HVAC OUTSIDE AIR .65 g X .23 g HVAC RETURN .34 g X Level 1 HVAC EXHAUST .23 g X .34 g TRANSFER AIR DUCT X GARAGE EXHAUST X GREASE KITCHEN EXHAUST DUCT (TYPE 1 HOOD EXHAUST) X NON - GREASE KITCHEN EXHAUST DUCT (TYPE 2 HOOD EXHAUST) X FLUES - BOILERS, HW HEATERS X PIPING HEATING WATER X CONDENSER WATER X NATURAL GAS X MAKEUP WATER X REFRIGERANT X PLUMBING COLD WATER (POTABLE) X COLD WATER (NON - POTABLE) X HOT WATER (POTABLE) X HOT WATER RECIRC (POTABLE) X CONDENSATE INDIRECT WASTE X NATURAL GAS MEDIUM PRESSURE (2 -5 PSIG) X NATURAL GAS LOW PRESSURE ( <14" WC) X RAINWATER LEADER/ OVERFLOW RAINWATER LEADER X UNDERSLAB DRAINAGE X SANITARY VENT X SANITARY WASTE X Piping Systems - High deformability elements and attachments (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .26 g .61 g .39 g .91 g Level 2 Ceiling .23 g .44 g .34 g .65 g Level 1 Ceiling .23 g .32 g .34 g .48 g Level 1 .23 g .23 g .34 g .34 g Piping Systems - Limited deformability elements and attachments (Converted to ASD) Level Component Ip =1.0 Component Ip =1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .36 g .61 g .55 g .91 g Level 2 Ceiling .26 g .44 g .39 g .65 g Level 1 Ceiling .23 g .32 g .34 g .48 g Level 1 .23 g .23 g .34 g .34 g General Mechanical Equipment - Boiler and furnaces, Other (Converted to ASD) Level Component Ip =1.0 Component Ip =1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .36 g .61 g .55 g .91 g Level 2 Ceiling .26 g .44 g .39 g .65 g Level 1 Ceiling .23 g .32 g .34 g .48 g Level 1 .23 g .23 g .34 g .34 g Piping Systems - Low deformability elements and attachments (Converted to ASD) Level Component Ip =1.0 Component Ip =1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .61 g .61 g .91 g .91 g Level 2 Ceiling .44 g .44 g .65 g .65 g Level 1 Ceiling .32 g .32 g .48 g .48 g Level 1 .23 g .23 g .34 g .34 g General Mechanical Equipment - Pressure Vessels and skirts free standing (Converted to ASD) Level Component Ip =1.0 Component Ip =1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .91 g 1.21 g 1.36 g 1.82 g Level 2 Ceiling .65 g 1.09 g .98 g 1.63 g Level 1 Ceiling .48 g .8 g .72 g 1.2 g Levell .3 g .5 g .45 g .76 g HVAC Systems - Vibration Isolated (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .91 g 1.21 g 1.36 g 1.82 g Level 2 Ceiling .65 g 1.09 g .98 g 1.63 g Level 1 Ceiling .48 g .8 g .72 g 1.2 g Level 1 .3 g .5 g .45 g .76 g HVAC Systems - Non - vibration Isolated, Mounted in -line with ductwork, Other (Converted to ASD) Level Component Ip = 1.0 Component Ip = 1.5 g Load g Load, with Exp. Anchors g Load g Load, with Exp. Anchors Level 3 Ceiling / Roof .36 g .61 g .55 g .91 g Level 2 Ceiling .26 g .44 g .39 g .65 g Level 1 Ceiling .23 g .32 g .34 g .48 g Level 1 .23 g .23 g .34 g .34 g General Mechanical Equipment - Boiler and furnaces, Other Level Component Ip = 1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof A AA AA AA* Level 2 Ceiling B A A AA Level 1 Ceiling B A A A Levell B B A A General Mechanical Equipment - Pressure Vessels on skirts and free standing Level Component Ip =1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof AA* AA* AA* - NA - Level 2 Ceiling AA AA* AA* - NA - Level 1 Ceiling A AA* AA* AA* Level 1 B AA A AA* Piping Systems - High deformability elements and attachments Level Component Ip =1.0 Component Ip =1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof B AA A AA* Level 2 Ceiling B A A AA Level 1 Ceiling 8 A A A Levell 8 B A A Piping Systems - Low deformability elements and attachments Level Component Ip = 1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof AA AA AA* AA* Level 2 Ceiling A A AA AA Level 1 Ceiling A A A A Levell B B A A Piping Systems - Limited deformability elements and attachments Level Component 1p = 1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof A AA AA AA* Level 2 Ceiling B A A AA Level 1 Ceiling B A A A Levell B B A A HVAC Systems - Vibration Isolated Level Component Ip = 1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling /Roof AA* AA* AA* - NA - Level 2 Ceiling AA AA* AA* - NA - Level 1 Ceiling A AA* AA* AA* Level 1 B AA A AA* HVAC Systems - Non-vibration Isolated, Mounted in -line with ductwork, Other Level Component Ip = 1.0 Component Ip = 1.5 SHL SHL, with Exp. Anchors SHL SHL, with Exp. Anchors Level 3 Ceiling / Roof A AA AA AA* Level 2 Ceiling B A A AA Level 1 Ceiling B A A A Levell B A A A c 0 c , 0 0 R <r 0 L z 0 -.: t 1 E 0 0 c c 0 cL' 0 • c c 0 a; c c C: BRACE ALL DUCTWORK AND PIPING PER SMACNA'S "SEISMIC RESTRAINT MANUAL" OR MASON INDUSTRIES "SEISMIC RESTRAINT MANUAL" IN ACCORDANCE WITH THE COMPONENT IMPORTANCE FACTOR AND THE SEISMIC HAZARD LEVEL (SHL) OR 'g' LOAD LISTED IN THE APPLICABLE TABLE. OBTAIN THE COMPONENT IMPORTANCE FACTOR FROM THE DUCT WORK OR PIPING MATRIX. SEISMIC RESTRAINTS MAY EXCLUDED WHEN 1. = 1.0: MECHANICAL AND ELECTRICAL COMPONENTS IN SEISMIC DESIGN CATEGORIES D, E, AND F WHERE Ip = 1.0 AND FLEXIBLE CONNECTIONS BETWEEN THE COMPONENTS AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT ARE PROVIDED AND THAT ARE MOUNTED AT 4 FT (1.22M) OR LESS ABOVE A FLOOR LEVEL AND WEIGH 400 LB (1780 N) OR LESS, [ASCE 7 -02 SECTION 9.6.1 - EXCEPTION #5] • MECHANICAL AND ELECTRICAL COMPONENTS IN SEISMIC DESIGN CATEGORIES D, E, AND F WEIGHING 20 LB (95 N) OR LESS WHERE Ip = 1.0 AND FLEXIBLE CONNECTIONS BETWEEN THE COMPONENTS AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT ARE PROVIDED, OR FOR DISTRIBUTION SYSTEMS WEIGHT 5 LB /FT (7N /M) OR LESS. [ASCE 7 -02 SECTION 9.6.1 - EXCEPTION #6] • SEISMIC RESTRAINTS ARE NOT REQUIRED FOR HVAC DUCTS WITH Ip = 1.0 IF EITHER OF THE FOLLOWING CONDITIONS ARE MET: A. HVAC DUCTS ARE SUSPENDED FROM HANGERS 12 IN (305 MM) OR LESS IN LENGTH FROM THE TOP OF THE DUCT TO THE SUPPORTING STRUCTURE, THE HANGERS SHALL BE DETAILED TO AVOID SIGNIFICANT BENDING OF THE HANGERS AND THEIR ATTACHMENTS. OR SEIS V IC BASIS OF SEISMIC RESTRAINTS MAY BE EXCLUDED WHEN __ 1.0 0 R I, = 1.5: DESIG\ • B. HVAC DUCTS HAVE A CROSS - SECTIONAL AREA OF LESS THAN 6 FT (0.557M [ASCE 7 -02 SECTION 9.6.3.10] • DUCTILE PIPING IN SEISMIC DESIGN CATEGORIES D, E, OR F DESIGNATED AS HAVING AN Ip = 1.0 AND A NOMINAL PIPE SIZE OF 3 IN. (75 MM) OR LESS. [ASCE 7 -02 SECTION 9.6.3.11.D.3] • EQUIPMENT ITEMS INSTALLED IN -LINE WITH THE DUCT SYSTEM (E.G. FANS, HEAT EXCHANGERS, AND HUMIDIFIERS) WEIGHING LESS THAN 75 LB (344 N) DO NOT NEED TO BE BRACED INDEPENDENT OF THE DUCT SYSTEM. [INTERPRETED FROM ASCE 7 -02 SECTION 9.6.3.10] UNBRACED PIPING ATTACHED TO IN -LINE EQUIPMENT SHALL BE PROVIDED WITH ADEQUATE FLEXIBILITY TO ACCOMMODATE DIFFERENTIAL DISPLACEMENTS. [ASCE 7 -02 SECTION 9.6.3.10] • PIPING - ROD HANGERS SHALL NOT BE USED AS SEISMIC SUPPORTS UNLESS THE LENGTH OF THE HANGER FROM THE SUPPORTING STRUCTURE IS 12 IN (305 MM) OR LESS. ROD HANGERS SHALL NOT BE CONSTRUCTED IN A MANNER THAT SUBJECTS THE ROD TO BENDING MOMENTS. [ASCE 7 -02 SECTION 9.6.3.11.4.C] S V AC\ A SEIS v is HAZA LEVEL DESIG\ • SEISMIC DESIGN VALUES ARE CALCULATED IN ACCORDANCE WITH IBC 2006. IBC FORCES ARE "STRENGTH DESIGN" BASED. VALUES HAVE BEEN USED TO SELECT FROM SMACNA ADDENDUM NO. 1 TABLE M-10 "NEW' VALUES IN ORDER TO USE THE SMACNA SEISMIC RETRAINT MANUAL. VALES: * 1/2 Brace Spacing Required * 1/2 Brace Spacing Required I VAC/SHF SHL -T V ETAL /EQ DFSIG\ VALJ * 1/2 Brace Spacing Required * 1/2 Brace Spacing Required VE\ T * 1/2 Brace Spacing Required * 1/2 Brace Spacing Required Highly Deformable Pipe Includes: Steel or Copper Piping with weld /braze /groove fitted joints. Limited Deformable Pipe Includes: PVC or PVDF Piping I A L HSIG PLU V VALU BI \G =S: * 1/2 Brace Spacing Required Low Deformability Piping Includes: Cast Iron, Glass Pipe, FRP (Fiberglass Reinforced Pipe) REVIE'E FOR CODE COMPLIANCE ,"' ROD APR 14 2009 City of Tukwila BUILDING MOO i HVAC/S S _i J V - -T S -1S V v- rAL/FOUiF is 'g' LOAD: IC ALLOWABLE STRESS DESIG\ VALES: ■ SEISMIC DESIGN VALUES ARE CALCULATED IN ACCORDANCE WITH IBC 2006. IBC FORCES ARE "STRENGTH DESIGN" BASED. VALUES HAVE BEEN CONVERTED TO "ALLOWABLE STRESS DESIGN" VALUES IN ORDER TO UTILIZE MASON INDUSTRIES SEISMIC RESTRAINT GUIDELINES. THESE VALUES CAN BE USED TO SELECT SEISMIC BRACING FROM MASON INDUSTRIES SEISMIC RESTRAINT GUIDELINES. V T P 11 9 1 \ Highly Deformable Pipe Includes: Steel or Copper Piping with weld /braze /groove fitted joints. Limited Deformable Pipe Includes: PVC or PVDF Piping fTh ss A D PLU V BI VIC 'g' LOAD G Low Deformability Piping Includes: Cast Iron, Glass Pipe, FRP (Fiberglass Reinforced Pipe) f109- 03 RECEIVED CITY OF TUKVVILA APR 0 6 2009 PERMIT CENTER m a 0 E ed O e 0 . 0 co c) • " N � r For Th PERMIT SET PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503- 331 -0234 EXPIRES: 9 -21 -09 z M0.3 instr e 01 Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 www.mckinstry.com L 0 0 LL L 0 LL CN.1 r- co CO C \1 CD N ISSUED / REVISED DATE 3/31/09 E 0 0 CV Q) co CV (g LL � u7 co 0) SEISMIC INFORMATION . . 12 LT; , ,,,---, r .10.0, .;......, V c V1/41 1,rtalkil re!IV 14 f ,,,,, irECV, iii "' , w...;;"::":::,79:."7:77. \ ' ' • " ' • IJII 1 . Ni 1, •I: 'I, 1, ' 1 li '' , . / l Tr' (13 IL 'qr „., . .. / i ' : ."-- ', ' _,,, ' ZL, '-'" - , - 0 te„Ic.., ,r0 ROP COUPLER' WF CORNERS ..co ALL THREAD 10 1'0 ,90 THREAD (EMBED 4" .., ,4, `Mt re.,0 — ---- ---- --- ROD & IN / , / '''' \ ...." / y / ', --'.... ,,--- ,. .. ---"- Ar" ,.......,__ ,,, 1 '' / / ., "'' .' '' ./ ..' .' 1 / raruauu . rr -- ' I' .: , I i 1 I ,... t .0 ft,...--t-„,t-.7t„,,, rz,c,...,2 . 1,,,r EA UNI-STROT w w/� A1"1,,,ROR 'DECK , , - ', 1 L_- WAY 2 GOBS 1 , P1D00 , w/P1546 / I / 0 BOLT ITA. WAY / 4 ' Polf. 1 ' 0 1 , 5T . DIOS: ai / (EMBED 4 1 / 6: i"0 THRU DOLT ..'"''F31:1151• ------4 w/COUPL,ER ANCHOR DE( -,, , I v / 7 „ / / , / ,'" ,'" , ,,,„ ," / / ,/ K) * 71,I(g , 3 LTL . r : li raA 3 1.,.„.4 I 01, , A- 1 ...,t 57. Ku r 7 % 7 '4 4 1 . 111111W1E WAIIIIWINARMIWIP,W11■11401WHWIN,WWWINN KIKE 00 ELATA rtc t; 7 E k 18 d 1r 8 8.0,8 7 E A rtit 1 a 3 8, fEculi Nact4 Tukwi la , INA 4,1,111U0 Er drthr114111X411r1WWWWW1441.111WW114414414.141414.1411,1141111141WWWWWWWWPWAIIMAPIKAPWWWIVAPPArMIMP......*Pre , SECTION A ' ” / 1 / / /' '' .'''''„ MIECH UNIT , ' / ,,... .,, / / / / / / / e'' „ „/ / / / / / ''' . ""' e ',/ 510.# MAX / ,, , / ,,,, / / / r , / / I-SIRUP' fd WES ---.'"-- , , . , 1 . P1000 . ,,, j . P. 2 14, CI., 1 (4 SIDES) .- - ' I ,,, ple...:: ------/' DAN; LLD. WWWWWWIIAWAhlr...WW,11.MI.FrWamwr.yr-rr I ENGD: D. LAKE , AlArr.11■141014.1.411.rairriOrWMIMairdoirimilliiilirlarra JOB NO :6913600 1 thhrIVA/11.11191r#141141WWWIIIP1114110W4PIOWIWWWW , , D 4 4r., WI.IIRIII.RAtraWWWWWIIIIWWWW L ii , 4 0 ' ' t I , 4... . , ' 4 " it 0II , 1. t r , ENGINEERS NORTFME ST, INC, 6869 'WOODLAW0.1 INIVE.1tE. , SEATTLE ,„ WASHINGMN 98115 0 r t c5 c 0 . _ 0 0 Cir; 0 s_ 0 0( 0 .1 1., S0'rtiuciuRAL kfl !I „ !' 1 1..1N.0 I N EIZIRS Enrtect g i N rihwest htc., C.34tTE: EAST Tukwl Nun p ' Uir TU AL CALCULATIONS elLtr,, • 1104.1 11.1. 7 "77 rrr : 4 , r':54 • FE40ED 41/4 "4, 1 I AN April 1, 2009 -ENVV Project-No. 99-136030.6 - N. I. % CA! T Cgs6p, Vti'Qc't1 lawn Ave ijue NE, to 4 WA' eiD116 20D:525075GO 206',622,6693 touwvocenvm Shear stren '11 ich terminatio Sitsoi glzeingtit ()Ado iever arm): Veralion,; V 1.1 Tocalie force: N I •4.14, Shear force: k/ .1/ 411„ Interaction': Company nem e Engineers Pam Powv. De..51.cin pu,sfst. f t - Project: Sabey Piroje ;1'r No.:099136030.S h eff tensile end shear forces IllicairriarealaiNctos , Steal Carre plate riot c,a1c0latp,41/riertifgrreciI 229.0Ib V I.yo 116•b tt 200 Ilb11116 lb 018 IM • =200 /015107 tb: 004 290.1b111 16 lb 0 v„ lit4, 11.2 ' '4 o 0.18.s . 1„.0 Eput argk grgtutto must be uhecaWW.,1 r nwi 11h the'ettioino g;olooltkins, Aft naliurnti TakikNiOWItt,fgulalofrner3. kind'f pta intbkay Paste nig 0 Va 'Dale; 41112009 Pal go; no* D.0:1 Reternce , PAWECT# PROJECT 11 .„ 5110/ECT 'L[ OF 411, L-C ?PK CI"( . • : ZAT 4 '1'919 • 'r2 • )-,„,) 1 1-'y t ' ' # ' •••• • • •••• • „::/ffa ENGINEIERS , ..1 1. 401.CLITWEsT, STrtrucTrIRAL'ENorNitERS .1.586:9 AvE, 114....E., 4.205, Stm7rAloVA 98115 ( (.206) .522 L I - 1 - 2 K 1 , J, • • •:.„„ 14'4 :re „ A ..... — .,• • '1:47,) F11-4 ,,/ .UV 4 // aj > „r,:t lJ1L t oirr PTt UK q" T ° t ,1 8:4;3, 4 • 1 TOtwritc:Vi A t4 evi ft ENGINEERS NORTHWEST, .1NC. •086 VIIGOOLAVIN AVE. N:E. SEATTLE VIASHINGTON 98115 • -'•- • • •,.• -• • END : 00, LAKE NO:99136030 DWN: SHEET: / Ira t " t t j r, , E, d 4 PS. L5'1 ANCHOR (EMBEL) 4 •: :V ALL REMO B .--r-77 1/4' • '1/4 °1/4 N • N. • ... r P1000 END CHANNEL :.sTucl , 44 EA, - END, THRU BOLT E.:1 COR,. TO KECK, UNIT FRAME„ I414Ze.:4.7X1r P- I 54B rU#2 N HOR c o y - (EMBED 4 & CHANNEL •NUT' STUD dc BPLT. lilt -STRUT P1000 EA. AY 2 r ORNERS wit P1544, wl cobisva 'r1 t r REVIEWED FOR CODE COMPLIANCE ARNIM/ED APR 1 4 2009 City of Tukwila BUILDING DIVISION 09 0310 RECEIVED CITY OF TUKWILA APR 0 6 Z009 PERMIT CENTER FOR REFERENCE ONLY 0 IMO ct 0 0 . ce 0 uJ I) 0 1— cD CN ISSUED / REVISED PERMIT SET 0 0 LL 4- 1. 0 LI— 0 co DATE SEISMIC BRACING FOR ACU instry le Of YEW Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503-331-0234 www.mckinstry.com 3/31/09 COrileriT11110US States 2003 NEHRP-Seismic."Design Provisions Latitude = 474918 Longitude = 4222904 Spectral Response Accelerations 'Ss and Si Ss„and.S1 = Mapped -Spectral:Acceleration Values Site Class - = 1.0 ,Fv 1,0_ Data ,are based on a a05 .deg grid,spcng Period Sa (sec) (9) 02 1.492 (Ss, 'Site Class E$.) 1,0 0;514 (SI, ,Site-Class El) Conterminous,48 States 2003VEHRP SelernicDesign Provisions Latitude 47.4918 Longitude = -1222904 Spectral Retipons:a.Addelarations SMs.nd :SM1 Ss and'.8M1 = FvxS1 D Period Sa (sec) (9) 02 1492 (SMs, Site Class D) 1,0 0:771 (SM1, Site Class D) Period Se (sec) (9) 0.2 0.994 (SDs,,Site Class p) 1,0 0.514 (SDI, SClass Corlierrnittous48:'Statos 2003, 'Seismic:DeSign Latitude .7 47:4918 Lorigitude= -1222904 'Design, Spectral Responso SDI SDs = 2/3 x •SMs -and 'SDI 2/3 x SMI Site Class!) "' Fa 1.0 iFy = 15 F mt. nt.,y1LLY , ffum",,,Y.,-^',. `, , "1.-- - -, ..-.--- - - - -1- - - Company name: Engineers NW PEK Powers Design Ae,,ir' Project:SR:bey Verson: V It1 Seisclerf ri :hor .Proutter.Stbrig- SDI 1t2 (7,00) rEffereliver embedrnerindepth: h 2O00 n. Nominal ernbedirnent depth: Th„a,a7.= 2,1500 In, Approval; Load diStribtrtion 1 resultant itt atoned loads Max, concrete comp:set I've"; strain: Max. concrete coprivr6sreiw stress: ResuIrding tension load; Rec oiling corn bres s Ion load; Seminary: Arm hot' plate: Strength tricitiction tar:i0!S: Steel strength: Concrete breckoninbuilout Seismic: kip Des ign method: Concrete: Loading combination: Seiarnio loading: ReInforcemont Stead-off installation: TerWon load 0 psi 200 lb 0 lb Verifkation Tensile force: Snearforce; kileraCtion: Material: Length - it widllh; input plate thickness: 'Calculated plate thickness: Project Ns.; 99136030 Q wi Tens Illarforce: Sheer forr:e: Terislieforce; Shear force; Tell •t•ercr force: Demand 200 lb 200 lb frr.ria.s 0s 4=0,05 ltt'rn. 0,7.0 = r 015 Anchor No. Capaotty •5107 lb • • 1110 lb cuotoire 36000 pei •a000• r rtirx e0010 i n 0.250 Ir notroalcuisted r Date: C14009 Page: 3/5 Tensile force 200 lb •tatile •0,04 1.1.1 OK 0,101c1r0 Lai da?410 and retalatLa noraat bo cbragakod a or alproaara ant autta It aulaailou co..amialictrat, hAith.nerlboate 011avalarthaJotOralkama and/ arpratalaiLly 1 ''.4'ptr ACt 3:1B.051;AppendiXD),:tartchor In metal deck Normai-q0Yeigatconcrete, cracked, 3000 pa takernfrom seetion'92 yes, yreidrciduCtile altmarnent; yes n s upplementary reinforcement • control splitting present .fl or. longitudinal edge- reinforcement orr <=.#4.1 bar Coridition.B (0,A /0.4.6) no•terta-cit 'Sneer lorce 200' th -Rale roma .0,64E1 04:4c • D.3,3t3 ..1,14,11•11,!•■••...1./.43•;••;,,,,....r,1•,,414••,•14,4,1•,',I,14,1••■•■•,•,•,:•',•;•14.-4,4,',II•r•I•rirt',1`,11,•,•••,,•••4•••••• rr,,,,,!•■•P.V.r.114.1-14•1•L•I':•,,:+or•r•■•■.k•■•:r1I•;•:!•■•14.1.1".„!...4•!'•■•!•1111j • ,4r, -"r"''' •,* vr•Fh tr,rrr,:tr, 11 'f'fwr))111' LO rtx..1 r r ' trr rr Arrk.,; ett, rrr: , rrrtarr,a rtrm tr rural' 4 , •; 1! .. , r■r r rr ., ' lr IINTrIrt74' ! Al , •? , ■ ,,,, r• 1 Per', krar 4•4,•,•.Pri•-11,Nr.•■•1,6;l•;'.^,1•01,1+1., 1 INN t•t , . . • . • • „ „ • : r I : r 1.... ;. ; I Ai,. $' ko)',:ir . • (d FM Ut3 • • IllitirdKeir',W$ LW 09.2,r (re.? rura.l.f.16,rk • 6 1 .4 4 111,62' rcirivermalawarr*thlropoor„ '10;38 —, arja • El VP,P01AICIT'd AIr [arr.! IN 1 O)11,,IECTIONS \ flkIU • 0.5a0 r'41g0 fri , ••• A.k • ' , .„ 1 1)1 F e fNIE .) 01 , 11 P CYAI Lr'R r k- ACCESS iPANEL : 120 24.0 IR (EAR 23, IP rt„, ••, r — ACCESS PANE.11,„ ("101 PISAT t 'DRAIN tifor' FPI) ,2 G9,6 \ \„. r, r• rr: p ., r0 "4 powers, Design Company name: Engineers Nril ir Project- Salley 'Project No.: 99135030.6 'Version: V' 1 .1 Termite graft Ft del rotirwation Mee ofjoilltr 4151 uzi Casa lin = •80 H.) N = •:750 *A:750 9030b =5107 IN uo i3ON,„„ = 2001 brI5107 [lb •= 004.• Putkitv't strongrth: t; (f„72500)L1:51'..1O = • 4r N p Nura I [I apLit aiafla and rea9va must a ; Loa Mao Itha.ar egbating cantirtlawas,,.v.„tall ateaaufa r o, ffi d,,,th vir g da L m ,. arta ur rpi ei Da te , W1/2008 Page: Q5 D5 1 r D.5,3.2 dompany name: Engineers NIN PoweN Design 4 ss151' Project: Ss loey Verviom V IA G. rna rid to Georriotryl(rroM11-sterate.j Load Project Pilo.: 99139030.6 inpuird.0 Eurid•rivaata nuriag , qtaamkef_a rovertrnent Y11i th o. extrriaing wandiziank v.zth ' • .\ r ,„ - 44, LT, rrartarrQ,.:.1.1"'rrrwr !:■•\`'' I ! Frei— r • Dale: 4/11/2009 Pa ge: 2/6 Factored design loads •00 VITA 200 '0 Iry .0,000' 101-4 osadfatt I 0:,00 0 LISOCI Eacentdo profile. 0 000 Irt.;` e 0 In .---- ,..... _. REVIEWED FOR CODE COMPLIANCE APPnOVED APR 1 4 2UU9 City of Tukwila BUILDING DIVIS10111 1 (n- 03 & RECEIVED CITY OF TUKWILA PR 0 6 2009 PERMIT CENTER FOR REFERENCE ONLY PERMIT SET M w 1— z Lil z 0 z z CO instry e Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PORTLAND: 12021 NE AIRPORT WAY SUITE PORTLAND, OR 97220 503-331-0234 0 2 1_ 0 Li- OE, 00 C N C www.mckinstry.com 0 0 ISSUED / REVISED DATE 3/31/09 SEISMIC BRACING FOR AC U L0 0) 0) (NO) co _o c"1 (o CD CN U- 4:k 1— uJ 0 oztd � [I 11I 'III' 1 “i 111 11 .1a11111 JA awl 44 : 744 :77-., 0 ,7 - i 1 tF f6r C 1F. 34 i4 1 M2.2 SCALE: 1/32" = 1' -0" Pdd zs'I .rdiJ 1dd Ft:; r -a IJ 2ND FLOOR HVAC PLAN SCOPE OF WORK FO THIS PER WORK CT RED UN I R PERMIT tqd.FIFFE 1 fitfi 1.1 000 0 hLJ fee i tled Ir. OTHER M08 -264 1 I: Elk gqa�ua „ ck tI - _ -[. u J r1J ......... _Gil LAA 4i c;J [I E! 1 REVIEWED CODE COMPLIANCE APPROVED APR 14 2009 City of Tukwila BUILDING .1)11/1 MO9O3 RECEIVED CITY OF TUKWILA APR 0 6 2009 PERMIT CENTER or ris EXPIRES: 9 -21 -09 z w 0 1- 1- 0 0 0 PERMIT SET M2,2 c� c a N Ca N C CD c0 a� c'3 W ;� cp (0 " ° o o N CU N N N a N instry e Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 -669 -6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503 -331 -0234 www.mckinstry.com 0_ cD 2 m ac? 90 < W W . I® C!7 d CD 1.0 ' � m LL] 1— z ISSUED / REVISED DATE 3/31/09 2ND FLOOR HVAC PLAN : 150x72 I RF 5201 D RF-5201 -C RF- 5201 -B RE-5201 -A r 1 50x60 VAV-5201 -1 SCOOP 1 00x48 94x40 34x20 )()I" -470 F ACU -5201 -1A DT8 -1 25 -610 P �) 140 1 70x 60 VFD (TYP) 1 08x60 16x8 SUPPLY . OPENING TO BE LOCATED NEAR HEAT }} pRE?DUC MDF, EQUIPMENT 1 70x60 2 COOP 136x60 1 92x60 96X48 VCD -43 FAST ACTINC MOD 1 50x70 P.O.C. FM 1 i M3.2 (0 Ift 36x50 ................ SCALE : 1/8" 1' -O" lig0 ig oa 0 0 0 00 9 090909( 0000000 0 0 a o 0 0 I . f 0 0; 0 a.o. �__ 0 0 10000000( 0 0 0 SD 68x60 68x60 2ND FLOOR ENLARGED HVAC PLAN SD 68x60 FIRE RATED SOFFIT FOR FIRE DAMPER PROVIDED BY CC WHEN SPACE PRESS ABOV 4-1 O RAI 1 "w mop O Nis R .IE- E PRESS F ALARM IS SENT N 25'Wx6'H EXHAUST LOUVER 100x60 LOUVER MOTORIZED DAMPER KEY SCOPE OF WORK FOR THIS PERMIT. ALL OTHER WORK COVERED UNDER PERMIT #M08 -264 SCOPE OF WORK FOR THIS PERMIT. ALL OTHER WORK COVERED UNDER PERMIT #N08 -264 REVIEWED FOR CODE COMPLIANCE APR 1 4 2009 City of Tukwila B UILDING DIVISION 1O'4o3 4? RECEIVED CITY OF TUKWILA APR 0 6 2009 PERMIT CENTER ISSUED / REVISED PERMIT SET z w to H 33,2 N CV 4- 0 0 LL L 0 E 0 Z 0 0 c YI d @ 4 N Lc) co C0 00 ett 0) N E C? is) 0 I`- 0) 0 c0 0) • N 00 co AD N N R) 00 CD Q N N I— LL instr 'Ye Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1 -800- 669 -6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503- 331 -0234 www.mckinstry.com EXPIRES: 9 -21 -09 DATE 3/31/09 2ND FLOOR ENLARGED HVAC PLAN COMPUTER ROOM AIR CONDITIONING UNIT (AIR COOLED) TAG # ACU- 5201 -1A (INDOOR) & ACU-5201-1B (OUTDOOR) MANUFACTURER STULTZ MODEL OHS- 084 -DAR SUPPLY FAN TYPE DWDI CENTRIFUGAL SUP. FAN CONFIG.(BLOW THRU /DRAW THRU) DRAW THRU UPFLOW /DOWNFLOW /CEILING MOUNTED CEILING NOMINAL TONNAGE 7 COOL CAPACITIES @ 80 DEG DB, 67 DEG WB -- (SENS/TOT) MBTU 32.4 /79.6 SUPPLY CFM (STANDARD) 2800 MAXIMUM EXTERNAL STATIC PRESSURE (INCHES OF W.G.) 0.5 SUPPLY FAN HP (STANDARD) 2 QUANTITY OF MOTORS /SUPPLY FANS 1/1 SUPPLY MOTOR EFFICIENCY WS ENERGY CODE COOLING COIL EAT (DB/WB) 64 / 61 COOLING COIL LAT 53.2 REFRIGERANT TYPE R -407C HOT GAS BYPASS YES FILTER EFF. ( %) 30% VOLTAGE /PHASE 460 / 3 ELECTRIC REHEAT COIL (STANDARD) YES HEATING CAPACITY (MBTU) 42 INDOOR UNIT FLA / MCA (AMPS) 22.7 / 28.8 OUTDOOR UNIT FLA / MCA (AMPS) 1.3 / 1.6 HUMIDITY CONTROL YES CONDENSATE PUMP YES OVERALL LENGTH (INCHES) 48" OVERALL WIDTH (INCHES) 69" OVERALL HEIGHT (INCHES) 27.5" INDOOR UNIT OPERATING WEIGHT (LBS.) 510 OUTDOOR UNIT OPERATING WEIGHT (LBS.) 260 DISCHARGE PLENUM YES EMERGENCY POWER NO CONDENSATE PUMP YES FACTORY MOUNTED STARTER YES SUPPLY SMOKE DETECTOR BY E.C. DISCONNECT BY E.C. 110 V. SERVICE OUTLET WITHIN 25' NA MODULAR AIR COOLED SCROLL CHILLER SCHEDULE TAG # CH -52A2 CH -52B2 QUANTITY OF ASSEMBLIES, QUAN. OF MODULES 10 (30T) MODULES EACH 10 (30T) MODULES EACH MANUFACTURER AIRSTACK ASP -30 AIRSTACK ASP -30 NOMINAL TONNAGE 300 TONS 300 TONS TOTAL TONS AT SPECIFIED CONDITIONS 268.1 268.1 MINIMUM CAPACITY @ SPECIFIED CONDITIONS 13.4 13.4 AMBIENT TEMPERATURE FOR RATING( °F) 95 °F 95 °F LOW AMBIENT OPERATION /ACCESSORIES YES - 0 °F YES - 0 °F GLYCOL PERCENTAGE IN FLUID (PE) 20 20 VOLTAGE /PHASE 460/3 460/3 SHORT CIRCUIT INTERUPT CAPACITY 22,000 AMPS 22,000 AMPS COMPRESSOR RLA 25A PER COMPRESSOR 25A PER COMPRESSOR CHILLER SINGLE POINT POWER YES. PER 5, 30TON MODULES YES. PER 5, 30TON MODULES CHILLER MCA (FOR 10, 30TON MODULES) 2 @ 292 AMPS 2 @ 292 AMPS CHILLER MOP (FOR 10, 30TON MODULES) 2 © 350 2 @ 350 kW /TON @ ARI CONDITIONS 1.05 1.05 FACTORY MOUNTED STARTER YES YES MIN FULL LOAD CHILLER PERFORMANCE (PER ARI 550/590) 3.37 COP 3.37 COP MIN INEGRATED PART LOAD VALUE (IPLV PER ARI 550/590) 18.8 IPLV 18.8 IPLV EVAPORATOR CONDITIONS(EWT /LWT) 51/40 °F 51/40 °F EVAPORATOR GPM 621 GPM 621 GPM TYPE OF REFRIGERANT R -407c R -407c ASSEMBLY LENGTH X WIDTH X HEIGHT (NOT INCL. BASE) 364 "x72 "x78" 364 "x72 "x78" UNIT OPERATING WEIGHT 20,000 LBS PER 10, 30TON MODULES 20,000 LBS PER 10, 30TON MODULES UNIT DISCONNECT BY ELEC. BY ELEC. VICTAULIC PIPE CONNECTIONS YES YES NOISE CRITERIA MAXIMUM DB LEVEL 30 FEET FROM CHILLER 76.5 76.5 RETURN FANS TAG# TAG # BASIS OF DESIGN RF- 5201 -A, RF- 5201 -B, RF- 5201 -C, RF- 5201 -D QUANTITY MODEL 4 BASIS OF DESIGN MANUF. SERVICE GREENHECK MODEL BELT DRIVE CABINET VADS- 54H21- 27 -B50 LOCATION CFM (SMOKE CONTROL, @ 165F) 2ND FLOOR ROOM 5203 SERVICE 0.5" VAV RETURN AIR FAN TYPE BHP (OPERATING) DIRECT DRIVE MIXED FLOW AIRFLOW NA 77,500 CFM STATIC PRESSURE VOLTAGE /PHASE 2 " BHP 85% MIN 46.84 HP MOTOR HP VFD 50 HP VOLTAGE /PHASE NO 480V/3o MOTOR EFFICIENCY ADJUSTABLE PITCH /FIXED PITCH SHEAVE 87.5% OR BETTER MOTOR RPM 528 1770 VFD FAN CLASS BY MECHANICAL TWO SPEED MOTOR NA NO MOTOR ENCLOSURE OVERALL HEIGHT TEFC ADJUSTABLE PITCH /FIXED PITCH SHEAVE 30 NEITHER, VFD FOR ADJ. OVERALL HEIGHT TOTAL WEIGHT (LESS ANY ACCESSORIES) 59 " OVERALL WIDTH NA 59" OVERALL LENGTH (DOES NOT INCLUDE ACCESS SECTION) THRUST RESTRAINT 69" MOUNTING TYPE INLET AND OUTLET SUSPENDED MOUNTING POSITION EMERGENCY POWER HORIZONTAL TOTAL WEIGHT (LESS ANY ACCESSORIES) BY ELEC. 1800 LBS BASE NA ISOLATOR NA NA THRUST RESTRAINT BMS ENABLED AND CONTROLLED NA FLEX CONNECTOR NA YES MOTION RESTRAINT SPECIAL COATINGS NOT REQUIRED SMOKE DETECTOR NA NOT REQUIRED DISCONNECTS MOTORIZED DAMPER PER SEC 1412.4.1 BY ELEC. STARTER (BY ELEC) - 9.7 NR VFD CONTROL (McK PROVIDE, ELEC INSTALL) YES ELECTRONIC 0 & M DATA YES 110 V. SERVICE OUTLET WITHIN 25' BY ELEC. OPTIONS /ACCESSORIES SPECIAL COATINGS NA OSHA APPROVED MOTOR COVER NA BELT GUARD NA INSPECTION SECTION W/ BOLTED ACCESS DOOR NA WIND SHROUD NA SPARK RESISTANT NA MOTORIZED DAMPER PER SEC 1412.4.1 NA SOUND POWER BY OCTAVE BAND INLET 63 107 125 108 250 105 - 500 101 1000 100 2000 101 4000 96 8000 96 EXHAUST FAN SCHEDULE TAG# EF- 5201 -1 BASIS OF DESIGN MANUF. GREENHECK MODEL BDF LOCATION 2ND FLOOR 5201 SERVICE SUITE 5201 PRINTER EXHAUST FAN TYPE BELT DRIVE CABINET CFM (OPERATING, @ 70F) 2,800 CFM (SMOKE CONTROL, @ 165F) NA T.S.P. OPERATING ) 0.5" T.S.P. (SMOKE CONTROL) NA BHP (OPERATING) 0.62 BHP (SMOKE CONTROL) NA MOTOR HP 1 VOLTAGE /PHASE 480/3 MOTOR EFFICIENCY 85% MIN MOTOR RPM 1750 VFD YES TWO SPEED MOTOR NO DIRECT DRIVE /BELT DRIVE BELT ADJUSTABLE PITCH /FIXED PITCH SHEAVE ADJ FAN RPM (OPERATING) 528 FAN RPM (SMOKE CONTROL) NA FAN CLASS 1 FACTORY CURB NA SITE BUILT CURB BY G.C. NA OVERALL HEIGHT 24" OVERALL WIDTH 30 OVERALL LENGTH 36 TOTAL WEIGHT (LESS ANY ACCESSORIES) 150 BASE NA ISOLATOR SPRING HANGER THRUST RESTRAINT NA FLEX CONNECTOR INLET AND OUTLET MOTION RESTRAINT YES EMERGENCY POWER NO SUPPLY SMOKE DETECTOR BY ELEC. DISCONNECTS wNFD SCR CONTROL (McK PROVIDE, ELEC INSTALL) NA ELECTRONIC 0 & M DATA YES BMS ENABLED AND CONTROLLED YES 110 V. SERVICE OUTLET WITHIN 25' NA GREASE EXH. UL 705/762 NA SPECIAL COATINGS NA OSHA APPROVED MOTOR COVER NA SPARK RESISTANT NA MOTORIZED DAMPER PER SEC 1412.4.1 YES SONES - 9.7 VARIABLE FREQUENCY DRIVE SCHEDULE VFD- RF-- 5201A, VFD -RF -5201 B, VFD -RF -5201 C, VFD -RF -5201 D VFD -EF- 5201 - 1 TAG # BASIS OF DESIGN MANUF. ABB ABB MODEL ACH 550 SERIES ACH 550 SERIES LOCATION INDOORS INDOORS SERVICE RF-5201A & B RF -5201 A & B MOTOR(S) SERVED QTY 1 EACH 1 EACH TOTAL MOTOR(S) SERVED HP 60 EACH 460 / 3 1 EACH 460 / 3 VOLTAGE /PHASE TOTAL FLA T -BAR MATERIAL MIN HERTZ ALUM ALUM MANUAL SWITCH BYPASS YES YES AUTO BYPASS NO NO REMOTE INITIATE BYPASS NO NO DISCONNECT BY FACTORY - - FUSED DISCONNECT BY E.C. YES YES CONTROL INTERFACE YES, BACNET YES, BACNET FACTORY PROVIDED REMOTE RESET INTERFACE NO NO CONTACTOR SELECTOR NO NO INPUT LINE REACTOR YES YES OUTPUT L.C. FILTER YES YES NEMA ENCLOSURE OPTION NEMA 1 NEMA 1 - ... - - - - : „ - =r---- ._ °_ - - -_ DEVICE TYPE EGGCRATE (EC) Duct system or Section SMACNA Pressure & Seal Classes Dimensions (Inside, overall) Inside clear dimensions shown. Overall, allow 4" add'I for flanges on rectangular Materials (duct, lining) Unlined galvanized duct, see submittal for gauge and reinforcement. Rectangular to have TDF connections, round may be spiral. Flex: 4' max. length, Thermaflex GKM or equal Fittings (shop built) Square corner w/ inserts or 5 -gore elbows, centerline radius of 1.0o Conical tees for bidirectional flow. Purchased fittings (dampers, louvers) 1 -1/2 Hr airfoil smoke fire dampers per UL555S 110V N.C. operator outside duct Insulation (indoor, outdoor) Outdoor: R -7, alum. jacket Indoor: R -3.3 Seismic (besides normal hangers) Rigid attachment to structure Testing requirement (field testing) none required HVAC Supply medium pressure (From AHUs) SMACNA 2" pressure, seal class A HVAC Return /Exhaust medium pressure (Inlet to AHUs/ Fans) SMACNA 2" pressure, seal class A Inside clear dimensions shown, also OD for round. Overall, allow 4" add'I for flanges on rectangular, plus Galvanized duct, 1" lining only where indicated on plans. See submittal for gauge and reinforcement. Rectangular to have TDFconnections, round may be spiral. Flex: ducts and 4" from sides of trench. Square corner w/ inserts or 5 -gore elbows, centerline radius of 1.Oo Conical tees for bidirectional flow. 1 -1/2 Hr airfoil smoke fire dampers per UL555S 110V N.C. operator outside duct Outdoor: R -7, alum. Jacket Indoor: R -3.3 Rigid attachment to structure none required T -BAR T -BAR MATERIAL RETURN AIR GRILLE SCHEDULE DEVICE TYPE EGGCRATE (EC) TAG # EC1 EC2 EC3 BASIS OF DESIGN - PRICE MODEL NO. 80F - SIZE PER CFM ON DRAWING RUNOUT SIZE (UNLESS NOTED OTHERWISE ON DRAWINGS) -- -- -- MAXIMUM CFM 600 1200 2400 FACE SIZE 24 X 12 24 X 24 24 X 48 MOUNTING (PROVIDE FRAME SUITABLE FOR CEILING TYPE) T -BAR T -BAR T -BAR MATERIAL ALUM ALUM ALUM PROVIDE PLENUM OR TRANSITION TO RECTANGULAR -- -- -- PROVIDE FRAME FOR DUCTED APPLICATION NO NO NO PROVIDE OPPOSED BLADE DAMPER NO NO NO PROVIDE STANDARD #26 WHITE FINISH YES YES YES DIFFUSER SCHEDULE TAG # DT6 DT8 DT10 DT12 DT14 BASIS OF DESIGN - PRICE MODEL NO. SMCD SMCD SMCD SMCD SMCD RUNOUT SIZE (UNLESS NOTED OTHERWISE ON DRAWINGS) 6" RD. 8" RD. 10" RD. 12" RD. 14" RD. MAXIMUM CFM 110 220 350 500 880 NECK SIZE 6X6 8X8 10X10 12X12 16X16 FACE SIZE 24 X 24 24 X 24 24 X 24 24 X 24 24 X 24 MOUNTING (PROVIDE FRAME SUITABLE FOR CEILING TYPE) T -BAR T -BAR T -BAR T -BAR T -BAR MATERIAL STEEL STEEL STEEL STEEL STEEL PROVIDE SHEET METAL OR DUCTBOARD PLENUM NO NO NO NO NO PROVIDE STANDARD #26 WHITE FINISH YES YES YES YES YES VAV PINCH BOX SCHEDULE ALL DIMENSIONS ARE IN INCHES UNIT NO. VAV- 5201 -1 VAV - 5201 -2 NAILER MODEL NO, 30 R 30 R UNIT SIZE 16 8 INLET DUCT SIZE (IN) 19x10 8 OUTLET DUCT SIZE (IN) 28x12.5 12x12.5 PRIMARY MAX. CFM 2440 860 PRIMARY MIN. CFM 300 200 E c c a 0 0 CD . 0 0 0 0 o C c Notes: 1. Provide 3 feet minimum of flex duct wherever flex duct is used to connect a diffuser to the ductwork. 2. If these plans conflict with architectural plans for diffuser placement, use the architect's placement if space allows. 3. Fiberglass duct liner is not to be used, 4. Provide and coordinate all access doors necessary to maintain, adjust and test HVAC components above the ceiling. SCOPE OF WORK FOR THIS PERMIT. ALL OTHER WORK COVERED UNDER PERMIT #M08 -264 x109- 03k' CO MPLIANCE API 4 200 Cit!LONG !VISION y of Tukwila RECEIVED CITY OF TUKVVILA APR 0 6 2009 PERMIT CENTER I ua EXPIRES: 9 -21 -09 1- Q 1- z 0 v 0 PERMIT SET 0 N N 0 2 0 W 1- Q 0 1- z ISSUED / REVISED N T- 1.0 co co 0) O o u_ te L - � � m O w M7 0 0 co v- C V 0 CD N u7 0) 0) in e of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTL■ND, OR 97220 503 -331 -0234 www.mckinstry.com DATE 3/31/09 HVAC SPECIFICATIONS AND EQUIPMENT SCHEDULES C3 N