Loading...
HomeMy WebLinkAboutPermit M09-042 - PROVIDENCEPROVIDENCE 3355 S 120 PL M09 -042 Parcel No.: 1023049069 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 3355 S 120 PL TUKW Cit■f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PROVIDENCE 3355 S 120 PL , TUKWILA WA SABEY CORPORATION 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA Contact Person: Name: LOU BAILEY Address: 5005 3 AV S , SEATTLE WA Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA Contractor License No: MCKINCL942DW DESCRIPTION OF WORK: INSTALLATION OF (2) SPLIT HEAT PUMPS AND ASSOCIATED DUCT Value of Mechanical: $58,379.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 2 0 0 0 0 0 0 0 * *continued on next page ** M09 -042 Permit Number: M09 -042 Issue Date: 05/07/2009 Permit Expires On: 11/03/2009 Phone: Phone: 206 396 -9764 Phone: (206)762 -23311 Expiration Date: 03/16/2010 Fees Collected: $860.19 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 2 Printed: 05 -07 -2009 Permit Center Authorized Signature: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: MO9 -042 Issue Date: 05/07/2009 Permit Expires On: 11/03/2009 Date: - 7-0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th of • I am autho ized to sign and obtain this mechanical permit. Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 G-a7 r Date: - )---at M09 -042 Printed: 05 -07 -2009 Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Tenant: PROVIDENCE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 5: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS Permit Number: M09 -042 Status: ISSUED Applied Date: 04/16/2009 Issue Date: 05/07/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the doc: Cond -10/06 M09 -042 Printed: 05 -07 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us air - moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M09 -042 Printed: 05 -07 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 11100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Date: ' e ! V doc: Cond -10/06 M09 -042 ordinances governing or local laws regulating Printed: 05 -07 -2009 Name: Mailing Address: E -Mail Address: Company Name: Mailing Address: ?,o, 2. 1. ak SriA-e-vi E -Mail Address: L a UV, Ier+C.ki rv511n • Coin Contractor Registration Number: WY) G k i r'Y c (. y YZ P kJ Contact Person: Company Name: Mailing Address: Contact Person: 4(4/241 4 Nd4(soo E -Mail Address: Contact Person: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us MECHANICAL PERMIT APPLICATION Loki ?i i Ii 5 o S 3 "2_4 4.'e 5. Lou b Q mcklr"5)z1. C VV)(, IGt ry S co - n arch' 1'� •Va dr )1 I -rak, i, /a Zr..I? 41l'd, K.tr rlci / 4 <10 . Can Company Name: 1(V\ & K ; wG I ' c ,, Mailing Address: P .0. 60 r 2(4, 6 y bpyy E -Mail Address: (I I d A 4. m e 1 (v S 4'n-y • G `)m H:\ApplicationsWorms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Mechanical Permit No. i tt,)101,- 0 1 Project No, or office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: / O 23 '1 9Ot 9 Site Address: 3355 12- n ' ?L Tenant Name: Pro,/ I d flirt , Property Owners Name: 5' b. DA. p Mailing Address: ) 220 T t.'IGW i C 4' Iry • f ' L €J1 ro-kar,7.0 lN/ fi State Zip Suite Number: City New Tenant: Day / Telephone: S 4 t-_ City Fax Number: Floor: Er Yes ❑ ..No CONTACT PERSON - W ho do we contact when your permit is ready to be issued lob - 3 1 76 9'J9 State Zip ZOO — 6 S - S -- 173/ MECHANICAL CONTRACTOR INFORMATION ty?e City Day Telephone: 'La 6 39 L -F74, 4' Fax Number: Z 0 6 -6 R - / / Expiration Date: 3 l 6- Z C/ b nK w/Z City Day Telephone: Fax Number: soot &Oa- State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record City State Day Telephone: Z D 6 " 032. - Fax Number: 2 06" 65 - / 40P- 9 t /6g State Zip 201 — 2.7 7 SZ /Z. 2o - 2 1C 1 - o92 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Zip 8(116 7_5/ Page 1 of 2 •Unit Type: Qty ' :Type: • Qty Unit Type: • • - Qty 'Boiler/Compressor: Qty . Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Z 2 Incinerator Comm/Ind (vNJerv56a -S Z • • 3 79' Scope of Work (please provide detailed information): ry 5 t /i// p v r ' O x g t ' e s5O G/ /J• 4-C A U -T Valuation of Project (contractor's bid price): $ Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric Signature: Date Application Accepted: BUILDING OWNER 0 UTHO ZED AG ,k) Gas ❑ Indicate type of mechanical work being installed and the quantity below: d 2 p ►f Other: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: L n u Jp• I I �il Day Telephone: 3 9' 76 V Mailing Address: 700 S� 312d Ave y Zip Date Application Expires: H : \Apphcations\Forms- Apphcatrons On Lme\2009 Applications\ -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh City t 01 1 it `I Date: '7 i State Staff Initials: Page 2 of 2 Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Applicant: PROVIDENCE Receipt No.: R09 -00691 Initials: User ID: Payee: WER 1655 ACCOUNT ITEM LIST: Description MCKINSTRY CO • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10275 685.19 Authorization No. MECHANICAL - NONRES RECEIPT Account Code Current Pmts 000.322.102.00.0 685.19 Total: $685.19 Permit Number: M09 -042 Status: APPROVED Applied Date: 04/16/2009 Issue Date: Payment Amount: $685.19 Payment Date: 05/07/2009 09:38 AM Balance: $0.00 PAY ENT RECEIVED doc: Receiot -06 Printed: 05 -07 -2009 Parcel No.: 1023049069 Permit Number: M09 -042 Address: 3355 S 120 PL TUKW Status: PENDING Suite No: Applied Date: 04/16/2009 Applicant: PROVIDENCE Issue Date: Receipt No.: R09 -00584 Initials: User ID: Payee: JEM 1165 ACCOUNT ITEM LIST: Description • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MCKINSTRY CO SERVICE ACCOUNT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10252 175.00 Authorization No. MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Account Code Current Pmts 000.322.102.00.0 2.96 000/345.830 172.04 Total: $175.00 Payment Amount: $175.00 Payment Date: 04/16/2009 10:13 AM Balance: $685.19 PAYMENT RECEIVED doc: Receiot -06 Printed: 04 -16 -2009 Projec i U J i ` d" Li, Type of Inspection: i ' A, e . . � , /t-- Address: i1. ass S Date Call Special Instructions: Y Date Wanted: j �}} G . 4 U i a.m p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 N3q-ozii PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. • COMMENTS: e f (-0 e : xE- A),4 I Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: Type of Inspection: "( Address. , J r D t o balled: Special Instructions: Date Wanted: - V ...— ka_mn.. p.m. Requester: Phone No: ivo4 - 012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspect: ot4 atd 'Date: / _ c)9 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Proj t: J"."en/r Type of Inspection: Al ep/ h- N Address: 3355 s /2'v fL Date Called: Special Instructions: Date Wanted: Requester: Phone No: c INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 R Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: f 4 _ /I q ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: Project: /U/ /( /t A1' /� Type of Inspection: /��a� rcP•`9 /,) / 5- 5 5 3 3 `2 d PG Date Called: Special Instructions: r . Date Wanted: �• ----- g a p.m. Requester: Phone No: Approved per applicable codes. • INSPECTION RECORD Retain a copy with permit /)10 5-4°52 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: ��-- 4s Pj , 0A, J��1 A Date: ..... v 9 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Corrections required prior to approval. r Project: PA I)vi roc - Av ct: Type of Inspection: Pr Address: 33sGr k S. Suite #: az) Pc_ Contact Person: Special Instructions: Permits: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: E INSPECTION NUMBER - " per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Tukwila, Wa. 98188 206- 575 -4407 1/13/06 PERMIT NUMBERS Corrections required prior to approval. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 COMMENTS: ✓L E 4 6Cv Wiz - (> C- tp. .7.004 0 Pi k nspector: Date: 4 /3 01 Hrs.: ( ACTIVITY NUMBER: M09 -042 DATE: 04 -16 -09 PROJECT NAME: PROVIDENCE SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: TM r u ir ding Division Public Works DETERMINATION OOECOMPLETENESS: (Tues., Thurs.) Complete Comments: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 � PERMIT COORD COPY � PLAN REVIEW /ROUTING SUP n APPROVALS OR CORRECTIONS: 0 Al 01/C Fire Prevention Structural Incomplete n DUE DATE: 04-21 -09 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route I I Structural Review Required n No further Review Required DATE: DUE DATE: 05 -19-09 Approved E Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator Not Applicable u n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Name Role Effective Date Expiration Date PEDERSEN, JAMIE D AGENT 03/16/2006 Status ALLEN, DEAN C PARTNER /MEMBER 03/16/2006 GENERAL MOORE, DOUGLAS J PARTNER /MEMBER 03/16/2006 ARCHIVED ALLEN, DAVID E PARTNER /MEMBER 03/16/2006 GENERAL TEPLICKY, JOSEPH PARTNER /MEMBER 03/16/2006 REREGISTERED License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WESTVI" 121 RF WESTVENT INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 12/6/1988 9/1/1994 ARCHIVED MCKIN' "372ND MCKINSTRY CO CONSTRUCTION CONTRACTOR GENERAL UNUSED 8/20/19631 /2/2008 REREGISTERED Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 TRAVELERS CAS 8 SURETY CO 104702039 01/03/2006 Until Cancelled $12,000.00 03/16/2006 Untitled Page • • General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MCKINSTRY CO LLC 2067623311 PO BOX 24567 SEATTLE WA 98134 KING Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602569922 ACTIVE MCKINCL942DW CONSTRUCTION CONTRACTOR 3/16/2006 3/16/2010 GENERAL UNUSED Other Associated Licenses Business Owner Information Bond Information Insurance Information Page 1 of 2 https: // fortress .wa.gov /lni/bbip/Detail.aspx 05/07/2009 SHEET NUMBER SHEET TITLE SCALE MO.0 DRAWING INDEX, SYMBOLS AND ABBREVIATIONS NONE M32 3RD FLOOR HVAC PLAN 1/8' = 1 M33 3RD FLOOR ENLARGED HVAC PLAN 1/8" = 1' -0" M3.4 ROOF ENLARGED HVAC PLAN 118" = 1' -0" M7,0 HVAC BASIS OF DESIGN & EQUIPMENT SCHEDULES NONE C C V-; C Cti Ui cr Q U- cc C z cc C cc cc ABBREVIATIONS GENERAL AD ADJ AFF AFC AG AMP ARCH AUTO AUX BD BHP BLDG BOP BOT BS BTU BT1JH CA COMPRESSED AIR CAB CABINET COND CONDENSATE CA CENTER LINE CLG CEIUNG CFM CUBIC FEET PER MINUTE CLG ' CEILING CO CARBON MONOXIDE CO2 CARBON DIOXIDE COL COLUMN CONC CONCRETE COND CONDENSER; CONDENSATE CONN CONNECT; CONNECTION CONSTR CONSTRUCTION CONTR . CONTRACTOR CTL CONTROL DET DETAIL DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DISCH DISCHARGE DIV DIVISION DN DOWN DS DISCONNECT SWITCH; DOOR SWITCH DWDI DOUBLE WIDTH, DOUBLE INLET DWG DRAWING DWI/ DRAIN, WASTE, VENT (E) EXISTING EA EACH EC ELECTRICAL CONTACTOR; END CAP EL ELEVATION ELEC ELECTRICAL ELEV ELEVATION EP ELECTRICAL PANEL; END PLUG EQUIP EQUIPMENT ESP EXTERNAL STATIC PRESSURE EXH EXHAUST EXIST EXISTING (F) FUTURE F FAHRENHEIT FA FCO FDC FDN FIG FIN GA GALV GC GEN' GPM GWB H HP HR HS HTG HIR ID LAB LF MAU MAX MBH MED MEZZ MFR MH MIN MISC MID NA NEG NIC NO NOM NTS OA OC OD OVHD POC PRELIM PSI PSIG QTY ACCESS DOOR ADJUSTABLE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ABOVE GROUND AMPERE ARCHITECT; ARCHITECTURAL AUTOMATIC AUXILIARY BOARD BRAKE HORSEPOWER BUILDING BOTTOM OF PIPE BOTTOM BIRD SCREEN BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR FIRE ALARM FLOOR CLEANOUT FIRE DEPARTMENT CONNECTION FOUNDATION FIGURE FINISH FTO FURNISHED AND INSTALLED BY OWNER FLEX FLEXIBLE FLG FLANGE - FIR FLOOR FO FUEL OIL FP FIRE PROTECTION FPM FEET PER MINUTE FT FOOT; FEET FTG FOOTING FURN FURNISH GAGE GALVANIZED GENERAL CONTRACTOR GENERATOR GALLONS PER MINUTE GYPSUM WALL BOARD HIGH HORSEPOWER; HIGH PRESSURE HEATING RETURN HEATING SUPPLY HEATING HEATER INSIDE DIAMETER /DIMENSION LABORATORY LINEAL FOOT MAKE -UP AIR UNIT MAXIMUM 1000. BRITISH THERMAL UNITS PER HOUR MEDIUM MEZZANINE MANUFACTURER MANHOLE MINIMUM; MINUTE(S) MISCELLANEOUS MOUNTED NOT APPLICABLE NORMALLY CLOSED NEGATIVE NOT IN CONTRACT NORMALLY OPEN; NUMBER NOMINAL NOT TO SCALE OVERALL ON CENTER OUTSIDE DIAMETER OVERHEAD POINT OF CONNECTION PRELIMINARY POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE QUANTITY R RELOCATED RAD RADIUS READ REQUIRED RPM REVOLUTIONS PER MINUTE SECT SECTION SF SQUARE FOOT SIM SIMILAR SPEC SPECIFICATION SQ SQUARE STD STANDARD STRUC STRUCTURAL TI TOG .. TOS 1W UG UNO VAV VD VER VED VSD W/ W/O HVAC . AC ACT AHU BDD BOD CC CRU CT CV DB . DIFF DMPR EA EAT ECG EF FCU FD FM FP FTU SAT SD SF S /FD SL SLSM SM SP TDH TG TOD TSP UH W WG WC . WH WSP CD. CHW CHR CHS CT EWT FHV LWT TOP TO BE DETERMINED TENANT IMPROVEMENTS TOP OF CONCRETE TOP OF STEEL TYPICAL UNDERGROUND UNLESS NOTED OTHERWISE VARIABLE AIR VOLUME VOLUME DAMPER VERIFY VARIABLE FREQUENCY DRIVE VARIABLE SPEED DRIVE WITH WITHOUT AIR CONDITIONING ACOUSTICAL CEIUNG TILE AIR HANDLING UNIT BACKDRAFT DAMPER BOTTOM OF DUCT COOLING COIL COMPUTER ROOM UNIT COOLING TOWER CONSTANT VOLUME DRY BULB DIFFUSER DAMPER EXHAUST AIR ENTERING AIR TEMPERATURE EGGCRATE GRILLE EXHAUST FAN FAN COIL UNIT FIRE DAMPER FREQUENCY MODULATION FIRE PROTECTION; FAN POWERED FAN TERMINAL UNIT GRD GRILLE, REGISTER, DIFFUSER HC HEATING COIL HR HEATING RETURN HVAC HEATING, VENTILATION AND AIR CONDITIONING LAT LEAVING AIR TEMPERATURE W LINEAR DIFFUSER MC MECHANICAL CONTRACTOR MECH MECHANICAL MOD MOTOR OPERATED DAMPER; MODULATING MUA MAKE UP AIR OA OVERALL; OUTSIDE AIR OBD OPPOSED BLADE DAMPER RA RETURN AIR RAT RETURN AIR TEMPERATURE RCP REFLECTED CEIUNG PLAN R1U ROOF TOP UNIT SUPPLY AIR SUPPLY AIR TEMPERATURE SMOKE DAMPER SUPPLY FAN SMOKE FIRE DAMPER SOUND LINED SOUND LINED SHEET METAL SHEET METAL STATIC PRESSURE TOTAL DYNAMIC HEAD TRANSFER GRILLE TOP OF DUCT TOTAL STATIC PRESSURE UNIT HEATER WET BULB WATER COLUMN WATER GAUGE PLUMBING AD AREA DRAIN CO CLEAN OUT; CARBON MONOXIDE DCW DOMESTIC COLD WATER DI-1 DOMESTIC HOT WATER DHWC DOMESTIC HOT WATER RECIRCULATION DSP DRY STANDPIPE EWC. ELECTRICAL WATER COOLER FD FLOOR DRAIN IE INVERT ELEVATION IN WC INCHES WATER COLUMN IW IONIZED WATER INDIRECT WASTE NPCW NON POTABLE COLD WATER ORL OVERFLOW RAINWATER LEADER PD PLANTER DRAIN; PRESSURE DROP PERT PERFORATED PLBG PLUMBING PRV PRESSURE REDUCING VALVE RPBP REDUCED PRESSURE BACKFLOW PREVENTER SD STORM DRAIN SS SANITARY SEWER VTR VENT THROUGH ROOF WASTE WATER CLOSET WATER HEATER WET STANDPIPE PIPING . BP BACKFLOW PREVENTER CONDENSATE DRAIN CHILLED WATER CHILLED WATER RETURN CHILLED WATER SUPPLY CONICAL TEE ENTERING WATER TEMPERATURE FIRE HOSE VALVE LEAVING WATER TEMPERATURE TOP OF PIPE PIPING IDENTIFICATION HVAC - - A - A COMPRESSED AIR PIPE COND COND CONDENSATE DRAIN PIPE - - CDR- - CDR CONDENSER WATER RETURN PIPE CDS CDS CONDENSER WATER SUPPLY PIPE CHS CHS CHILLED WATER SUPPLY PIPE -CHR - - - - CHR CHILLED WATER RETURN PIPE G G NATURAL GAS PIPE -HR- HR HEATING WATER RETURN PIPE HS HS HEATING WATER SUPPLY PIPE RL RL REFRIGERANT LIQUID PIPE RS . RS REFRIGERANT SUCTION PIPE ST ST STEAM SUPPLY PLUMBING GRW GAIN - ID IRR NP ORL PW SS -, VD W W FIRE PROTECTION DSP FDC FP -- FIN - WSP VALVES PSD RWL — RWL— — SD PIPING FITTINGS ii 15I 101 TEE W /PIPE UP TEE DOWN W /ELBOW TEE UP W/ ELBOW TEE UP TEE DOWN +4 90' ELBOW UP 1 90' ELBOW DN CAP UNION tl FLANGE FLEX HOSE CONNECTION DOUBLE BELLOWS FLEX CONNECTION SINGLE BELLOWS FLEX CONNECTION FLOW ARROW CONCENTRIC REDUCER ECCENTRIC REDUCER SLOPE SYMBOL BREAK OR CONTNUAT1ON SYMBOL DOWN SPOUT NOZZLE II CLEANOUT Ix 45' ELBOW I ' 45' ELBOW 90' ELBOW r-, 1+ It' oio �QI PIPING ACCESSORIES 4 "V VIAV I Q 4 WATTS /LF RPBP Y 0 6 It! T CW COLD WATER PIPE (POTABLE) GRW GREASE WASTE GAW GARAGE WASTE HW HOT WATER PIPE (POTABLE) HWC HOT WATER CIRCULATING (POTABLE) ID INDIRECT DRAIN IRR IRRIGATION WATER PIPE NPCW NON- POTABLE CW PIPE ORL OVERFLOW RAINWATER LEADER PW PUMPED WASTE PSD PUMPED STORM DRAIN RWL RAINWATER LEADER BELOW GRADE RWL RAINWATER LEADER SD STORM DRAIN PIPE SS SANITARY SEWER PIPE (SITE) UD UNDERDRAIN PIPE ✓ VENT PIPE (SANITARY) W WASTE PIPE W WASTE PIPE BELOW GROUND DSP FDC FP FW WSP DRY STAND PIPE FIRE DEPT, CONNECTION PIPE FIRE SPRINKLER PIPE FIRE PROTECTION WATER PIPE FIRE PROTECTION WASTE PIPE WET STAND PIPE 90' ELBOW CROSS 1+1 _. TEE WYE TAP HOSE CONNECTION MOTORIZED 2 -WAY VALVE MOTORIZED 3 -WAY VALVE PRESSURE REDUCING VALVE CONTROL VALVE RELIEF VALVE BALL VALVE 3-WAY GATE VALVE BUTTERFLY VALVE DIAPHRAGM VAVLE CHECK VALVE NEEDLE VALVE GLOBE VALVE GLOBE VALVE ANGLE GLOBE VALVE 3 -WAY GATE PLUG VALVE BALANCING VALVE HOSE BIBB PUMP MANUAL AIR VENT AUTOMATIC AIR VENT HIGH CAPACITY AIR VENT SHOCK ARRESTOR FLOW SWITCH VACUUM BREAKER PRESSURE GAUGE TEMPERATURE SENSOR TEMPERATURE INDICATOR AUTO FLOW VALVE FLOW METER . Y STRAINER Y STRAINER W/ BALL VALVE PIPE SLEEVE STEAM TRAP PETES PLUG HEAT TRACING SUCTION DIFFUSER W/ STRAINER REDUCED PRESSURE BACKFLOW PREVENTOR FUNNEL DRAIN FLOOR DRAIN ROOF DRAIN ROOF OVERFLOW DRAIN DUCTWORK ACCESSORIES r, El= T 12x12 SL 12x12 2 "SL LiI DUCTWORK RECTANGULAR DUCT x RECTANGULAR DUCT I x RECTANGULAR DUCT RECTANGULAR DUCT BIRDSCREEN OR SCREENED OPENING SUPPLY GRILLE + RETURN OR EXHAUST GRILLE VOLUME DAMPER MOTOR OPERATED DAMPER C�) AIRFLOW MONITOR REMOTELY OPERATED VOLUME DAMPER (YOUNG REGULATOR OR APPROVED) BACK DRAFT DAMPER COORDINATE WITH CEILING APPURTENANCES. FLEX CONNECTION FIRE DAMPER THROUGH WALL FIRE DAMPER THROUGH FLOOR FIRE /SMOKE DAMPER THROUGH WALL FIRE /SMOKE DAMPER THROUGH FLOOR ACCESS DOORS 1" ACOUSTICALLY LINED DUCT 2" ACOUSTICALLY LINED DUCT CHANGE OF ELEVATION RISE(R) DROP(D) TRANSITION TURNING VANES SMOKE DETECTOR RETURN / EXHAUST / OUTSIDE AIR SUPPLY / TRANSFER AIR TERMINAL UNITS - SEE SCHEDULE FOR TYPE SUPPLY AIR DUCT TURNING UP OR TOWARD SUPPLY AIR DUCT TURNING DOWN OR AWAY EXHAUST OR RETURN AIR DUCT TURNING UP. OR TOWARD EXHAUST OR RETURN AIR DUCT TURNING DOWN OR AWAY ROUND. DUCT TURNING UP OR TOWARD ROUND DUCT r ----77 0 TURNING DOWN OR AWAY \MMM OVAL DUCT TURNING UP OR TOWARD OVAL DUCT TURNING DOWN OR AWAY VVVVV FLEXIBLE DUCT INSTRUMENTATION AND CONTROLS 0 THERMOSTAT SENSOR CARBON MONOXIDE SENSOR VISUAL ALARM LIGHT - WALL MOUNTED GRILLE/REGISTER/DI FFUSER DOUBLE LINE HVAC VAV BOX TAG S- C8 -09 -A 1 DUCT WORK EQUIPMENT TAG LOUVER TAG ANNOTATION IEF -2= B1 -1 LEGAL DESCRIPTION LOCATION / SITE MAP CEIUNG SUPPLY AIR DIFFUSER CEIUNG SUPPLY AIR DIFFUSER (SHOWN WITH THROW ARROWS) CEILING RETURN, EXHAUST OR TRANSFER AIR GRILLE LINEAR DIFFUSER (CEIUNG) LINEAR DIFFUSER (WALL) LOUVER PLAN . VIEW LOUVER (ELEVATION VIEW) 0 ROUND DUCT SYMBOL FLAT OVAL DUCT SYMBOL EQUIPMENT TAG I CONUTIVE EQUIP . T FLOOR OF EQUIP. LOCATION EQUIPMENT DESIGNATION LINEAR DIFFUSER GRILLE GRILLE, REGISTER, OR DIFFUSER TAG DT5-618 CFM EACH 1 SIZE TYPE CODE W5/3 -300 - CFM EACH I . ACTIVE LENGTH IN FT. TOTAL LENGTH IN FT. 1 Y° E CODE FLOOR III - DISCRETE BOX # SEE BELOW PRIMARY CFM FAN CFM ACOUSTICAL ACCESSORIES (IF REQ'D) KW OF AUX. HEAT. VAV BOX SIZE; SEE SCHED. SERIES FAN POWERED BOX (5) PARALLEL FAN POWERED BOX (P LOUVER TAG CONSECUTIVE LOUVER #. FLOOR LOCATED FACADE DESIGNATION B BANK M - MUSEUM NE 1/4 OF THE SE 1/4 AND , SE 1/4 OF THE SE 1/4 OF SECTION 9 AND GOV'T LOT 15 AND SW 1/4 OF THE SW 1/4 OF SECTION 10, T23N,, R4E., W.M. CITY OF TUKWILA, KING COUNTY, WASHINGTON. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include ad ditional plan rev iew'fees. GENERAL INFORMATION SYMBOLS SEPARATE PERMIT REQUIRED FOR: McChanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION NEW MECHANICAL WORK FUTURE Ti SCOPE & NEW WORK OTHER THAN MECHANICAL DEMO MECHANICAL WORK DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL /DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN PLAN NUMBER SHEET NUMBER WHERE, PLAN SHOWN REVISION NUMBER - DENOTES NUMBER AND DATE WHEN REVISION OR ISSUE OCCURED REVISION CLOUD DENOTES AREA OF CHANGE DETAIL REFERENCE OUTLINE WITH NUMBER AND SHEET LOCATION MATCHLINE 4 COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS: PLUMBING FIXTURE CALL -OUT (SEE PLUMBING SCHEDULES) DRAWING NOTE REFERENCE POINT OF CONNECTION CENTERLINE STRUCTURAL BEAM PENETRATION (SEE M503) STRUCTURAL BEAM HAUNCH (SEE M503) GENERAL NOTES: 1. VERIFY LOCATIONS AND DIMENSIONS OF ALL EQUIPMENT AND COORDINATE ALL WORK PRIOR TO START OF CONSTRUCTION: 2. OBTAIN APPROVAL OF STRUCTURAL ENGINEER PRIOR TO INSTALLATION OF PENETRATIONS NOT PREVIOUSLY COORDINATED OR AGREED UPON, I.E. ANCHOR BOLT DEPTHS, ETC. 3. CONCRETE EQUIPMENT CURBS, PIPING RAT SLABS, SUMP BASINS, AND HOUSEKEEPING PADS ARE SHOWN FOR APPROXIMATE LOCATION AND SIZE AND ARE TO BE PROVIDED BY THE GENERAL CONTRACTOR. WHERE PROVIDED, REFER TO STRUCTURAL INFO FOR ADDITIONAL DETAILS. A. PROVIDE RECORD DRAWINGS OF. THE ACTUAL INSTALLATION TO THE OWNER (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 14162.4.3) O THE OWNER ALL NECESSARY SYSTEM OPERATION AND MAINTENANCE MANUALS (PER B. PROVIDE _ TH MANUALS WASHINGTON STATE ENERGY CODE SECTION 14162.42) C. BALANCE ALL HVAC SYSTEMS AND PROVIEI'F. TO THE OWNERA WRITTEN BALANCING REPORT (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.221) D. EQUIPMENT/SYSTEMS TESTING SHALL BE PERFORMED IN ACCORDANCE WITH APPROVED PLANS (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.3.1). E. TEST, CALIBRATE AND ADJUST ALL HVAC CONTROLS AND SEQUENCES OF OPERATION IN ACCORDANCE WITH THE APPROVED PLANS (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 14162.12), NECESSARY TESTS ARE IDENTIFIED IN 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.3.1; PREPARE A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416.2.5.1); PROVIDE TO THE OWNERA FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS (PER 2006 WASHINGTON STATE ENERGY CODE SECTION 1416252). 5, PERFORMANCE OF ALL NEW BUILDING MECHANICAL SYSTEMS WILL COMPLY WITH OR EXCEED THE MINIMUM REQUIREMENTS AS SET FORTH IN THE 2006 WASHINGTON STATE ENERGY CODE SECTION 1410 GENERAL REQUIREMENTS. 6. MINIMUM VENTILATION QUANTITIES WILL COMPLY WITH OR EXCEED THE 2006 INTERNATIONAL MECHANICAL CODE. 7. ALL MOTORS WILL COMPLY WITH CHAPTER 15 OF THE 2006 WASHINGTON STATE ENERGY CODE. FOR ADDITIONAL DETAILS, SEE EQUIPMENT SCHEDULES CONTAINED WITHIN THIS DRAWING SET. 6. ALL SYSTEMS WILL BE INSULATED AS PRESCRIBED IN CHAPTER 14, TABLE 14-5 OF THE 2006 WASHINGTON STATE ENERGY CODE. FOR ADDITIONAL DETAILS, SEE DUCTWORKAND PIPING SPECIFICATION MATRICES CONTAINED WITHIN THIS DRAWING SET. 9. VERIFY THAT ALL NECESSARY INFORMATION HAS BEEN PROVIDED MICR TO CONNECTION OF EQUIPMENT FURNISHED BY THE OWNER OR OTHERS. 10.FOR ADDITIONAL SYSTEM AND EQUIPMENT SEISMIC REQUIREMENTS, REFER TO STRUCTURAL INFORMATION (WHERE PROVIDED) AND PROJECT SPECIFIC SEISMIC DESIGN INFORMATION SHEET CONTAINED WITHIN THIS DRAWING SET. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 4 2009 /6 City of iNkwila BUI n1V1� I CN RECEIVED CITY OF TUKWILA APR 16 2009 PERMIT CENTER a r Permit N Plan review approval is sublect toes ors and omissions. Approval of construction documents does not authorize the violation of any adopted cue or�or finance. fieceIpI of approved Field ' ' , r► T: d l : ; a ri Q1] yt3u. PROJECT: PROVIDENCE OFFICE SPACE SDC 5203 3355 S. 120th Place Tukwilla, WA 98168 REGISTRATION: REVISIONS: EXPIRES; 8 - 21 - 08 1 04/14/09 PERMIT SET City Of Tukwila BULDINGTAVISION NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: T. MARINO DRAWN BY: CHECKED BY: B. DAGGETT JOB NUMBER: DATE: 04- 10--09 SCALE SEE, DRAWING SHEET TITLE: DRAWING INDEX, SYMBOLS, AND ABREVIATIONS SHEET NUMBER: 5 instry fe Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800 -669 -6223 ENGINEERING M0.0 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503-331-0234 www..mckinstry.com E C Cr: C - 0 z S 0. _ z Li_ C C L C 2 C N C 2 C C C: C C- U; C^ u C C) t) C "0 C 4- Q L C Q7 0 L 0 C\ C (I: C C C C U. L C C c C C CC v. C ' CD -C e; C!: PLITTER CONNECT TO EXISTING 02x18 60x18 RA016 78x60 1 16x76 __ -- _ I�Yrf9 1111111111•■•Lii api i 10-3001 ILA 99X9 QUIP. I RA017 126x70 24x 18 - S SA003 1 144x63 SA004 60x18 SA004 60x18 SA002 C, L A `T l_) CG- 16100' ACU- 5203 --2A MIN AIR FROM EXIST UNIT (15% OSA) EXISTING 99x99 SUPPLY AND RETURN DUCTWORK UP TO 3RD FLOOR (3 TYP) 150x70 126x70. UL)- 200 (TYP 2) REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 4 2009 VAV -5201- DUCT INSTALLED UNDEF PERMIT SCALE: SHEET TITLE: "fe I EXPIRES: 9-21-09 04/14/09 PERMIT SET B. DAGGEI T 04-10-09 SEE DRAWING ACU -5203 1A 1 MIN AIR FROM EXIST UNIT (15% OSA) • M3.2 3/8"LIQUID & 7/8 "GAS 2ND FLOOR ENLARGED HVAC PLAN SCALE ; 1/8 ".1` MO9 RECEIVED CITY OF.TUKVV1LA APR 1 6 2009 PERMIT CENTER PROJECT: PROVIDENCE 3355 S. 120th Place Tukwilla, WA 98168 REGISTRATION: ns fry Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 REVISIONS: NO. DATE DESCRIPTION PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503 -331 -0234 www.mckinstry.com McKINSTRY DIVISION: DESIGNED BY: T. MARINO DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SHEET NUMBER: ENGINEERING M3.2 cc >. 0 tf ) tf ; Q: 0 C C U C C rn C ' 6 1 C U- -C C i C U C L -C > C c U C c - C C L' 0 cN. «. C C C-r; a) C c 0 C X FUTURE 96x60 OSA 120x141 SA CAP FOR FUTURE 717 AHU-52D1 CONNECT TO EXISTING 99x99 SUPPLY AND RETURN CAPPED AT FLOOR AHU -5281 1 08x60. 122x60 DEVIL SEE FSMD -7 96x60 OSA (TYP 4) REVIEWED FOR CODE COMPLIAN APPROV MAY 0 4 2009 City of Tukwila BUILDING DIVISION I 122x60. AHU -52A2 120x141 SUPPLY. MANIFOLD 122x60 I AHU -52A1 I 150x60 SLPPLY OPENING IN FRONT OF AHU (2 PER AHU) REVISIONS: EXPIRES: 9 -21 -09 04/14/09 PERMIT SET B. DAGGETT 04 -10 -09 SEE DRAWING OF WORK FOR This PERMIT 99x99 SUPpLY AND RETURN SHAFTS DN TO 2ND FLOOR. FUTURE AHU r' REF LINES UP TO ROOF . f AHU -52C2 I T I zl AHU -52C1 FOR AHU DETAIL SEE ISMD -9 Lo„ FOR CHW COIL CONNECTION DETAIL SEE 3RD FLOOR ENLARGED HVAC PLAN SCALE : 1/8" 1'- 014) 2. RECEIVED CITY OF TUKWILA APR 16 2009 PERMIT CENTER PROJECT: PROVIDENCE OFFICE SPACE SDC 5203 3355 S. 120th Place Tukwilla WA 98168 REGISTRATION: McKINSTRY DIVISION: DESIGNED BY: T. MARINO DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: 3RD FLOOR ENLARGED HVAC PLAN SHEET NUMBER: DATE DESCRIPTION instry le Of Your Building ENGINEERING M3.3 SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503- 331 -0234 www.mckinstry.com FOR CHILLER CONNECTION DETAIL SEE F" CHW SUPPLY & ` RETURN ti 1O "CHW RETURN TO 3RD, FLOOR 6" CHW SUPPLY '& RETURN 8" CHW SUPPLY DESIGNED BY: T. MARINO DRAWN BY: CHECKED BY: B. DAGGETT JOB NUMBER: DATE: 04 -10-09 SCALE: SEE DRAWING • • r SCOPE OF WORK FOR THIS PERMIT l ACU - 5203 -2B ACU - 5203 -1 B ROOF ENLARGED HVAC PLAN SCALE : 1/8" 1' —O" REF LINES DN TO 3RD FLOOR 3/8 "LIQUID & 7/8" GAS I\ RECEIVED CITY OF TUKWILA APR 16 2009 PERMIT CENTER inst Ye Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503-331-0234 www.mckinstry.com PROJECT: PROVIDENCE OFFICE SPACE SDC 5203 3355 S. 120th Place Tulovilla, WA 98168 REGISTRATION: REVISIONS: McKINSTRY DIVISION: ENGINEERING M3.4 SPLIT SYSTEM HEAT PUMP DEVICE TYPE EGGCRATE (EC) TAG # INDOOR UNIT TAG # ACU- 5203 -1A ACU- 5203 -2A OUTDOOR UNIT TAG # ACU- 5203 -18 ACU- 5203 -2B BASIS OF DESIGN MANUF. TRANE TRANE - MODEL 4TWR4048C 4TWR4048C AREA SERVED /LOCATION SERVER ROOM SERVER ROOM TOTAL / SENSIBLE BTU /H COOLING CAPACITY 30789/30389 30789/30389 TOTAL MBH HEATING W /BOOSTER HTR. NA NA CFM / EST 1380 1720 BOOSTER HEATER KW NA NA FAN MOTOR FLA 7 7 VOLTAGE /PHASE 230/60 230/60 EMERGENCY POWER NO NO SMOKE DETECTOR NO NO MATCHING OUTDOOR UNIT TEE3F65 TEE3F65 SEER 15 15 REFRIGERANT TYPE R-410 8-410 INDOOR UNIT EQUIPMENT WEIGHT (LBS) 196 196 INDOOR UNIT EQUIPMENT DIMENSIONS (LXWXH) 63X26)(23: 63X26X23 EQUIPMENT WEIGHT (LBS) 303 303 EQUIPMENT DIMENSIONS (LXWXH) 37X37X45 37X37X45 OSA ECONOMIZER NONE .' NONE RETURN /EXHAUST /TRANSFER AIR GRILLE SCHEDULE DEVICE TYPE EGGCRATE (EC) TAG # EC1 EC2 Era EC4 EC5 EC6 EC7 EC8 BASIS OF DESIGN -PRICE MODEL NO. 80P -, SIZE PER CFM ON DRAWING RUNOUT SIZE (UNLESS NOTED OTHERWISE ON DRAWINGS} SMCD - — 10" RD. 12" RD. 16" RD. 18" RD. 20" RD. MAXIMUM CFM 600 1200 2400 350 600 1200 1800 2400 FACE SIZE 24 X 12 24 X 24 24X48 12X12 24X12 24 X 24 24 X 36 24X48 MOUNTING (PROVIDE FRAME SUITABLE FOR CEILING TYPE) T -BAR T -BAR T -BAR T -BAR T-BAR T -BAR T-BAR T -BAR MATERIAL ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM PROVIDE PLENUM OR TRANSITION TO RECTANGULAR — — -- YES YES YES YES YES PROVIDE FRAME FOR DUCTED APPLICATION • NO • NO • NC • YES YES YES YES YES PROVIDE OPPOSED BLADE DAMPER NO NO NO NO NO NO NO NO PROVIDE STANDARD #26 WHITE FINISH YES YES YES YES YES YES YES YES DIFFUSER SCHEDULE TAG # DT6 DT8 DT10 DT12 DT14 DT16 BASIS OF DESIGN - PRICE MODEL NO. SMCD SMCD SMCD SMCD SMCD SMCD RUNOUT SIZE (UNLESS NOTED OTHERWISE ON DRAWINGS) 6" RD. 8" RD. 10" RD. 12" RD. 14" RD. 16" RD. MAXIMUM CFM 110 220 350 500 880 1120 NECK SIZE 6X6 8X8 10X10 12X12 16X16 18X18 FACE SIZE 24 X 24 24 X 24 24 X 24 24 X 24 24 X 24 24 X 24 MOUNTING (PROVIDE FRAME SUITABLE FOR CEILING TYPE) T -BAR T-BAR T -BAR T -BAR T -BAR T -BAR MATERIAL STEEL STEEL STEEL STEEL STEEL STEEL PROVIDE SHEET METAL OR DUCTBOARD PLENUM NO NO NO NO NO NO PROVIDE STANDARD #26 WHITE FINISH YES YES YES YES YES YES OFFICE SPACE LOAD (1865 SF) ITEM QUANTITY WATT /ITEM BTU /REM TOTAL BTU PRINTER 1 540 1842 . 1842.48 42" LCD 4 240 819 3275.52 PC 8 55 188 1501.28 19" MONITOR 22 ' 220 . 751: 16514.08 LAPTOPS 4 240 819 3275.52 VOIP PHONES 10 60 205 2047.2 PEOPLE 10 NA . 250 2500 LIGHTS NA 1865 6363 6363 SERVER ROOM LOADS (600 SF) ITEM QUANTITY WATT/ITEM BTU /ITEM TOTAL BTU SERVERS 4 2040 6960 27842 PEOPLE 2 NA 250 500 LIGHTS 3 NA 600 2047 2047 E. C C to c; C c cs, C N c� C C f . C 3 C C G C C- ( C 4- C C C C C L Ci C C 3 C Ur) c 0 C C . C C; c C C v: C 0 fli C C) C L C C i C Gp C C; NOTE 1 PROVIDE SEPARATE EXTERNAL CONDENSATE PUMP: MAKE: LITTLE GIANT MODEL #: VCMA -20 -ULST 554200 POWER REQUIREMENTS: 120V 1 PH 1.5 AMPS, AND LOW VOLTAGE THEMOSTAT FOR REMOTE MOUNTING: NOTE 2 - PROVIDE LOW AMBIENT CONTROL TO 27°F BASIS OF DESIGN EXISTING SYSTEM SERVING EXISTING CFM NEW CFM TOTAL SYSTEM CFM MINIMUM OSA OFFICE/NOC 2900 2100 5000 12% • VENTILATION REQUIREMENTS MINIMUM O5A EXISTING AHU MIN OSA SET POINT 240 CFM 12% ECONOMIZER REQUIREMENTS NO ECONOMIZER REQUIRED 2006 WSEC TOTAL: NOTES: , 1. EQUIPMENT LOAD VALUES FROM RANDY LANGFORD' S EMAIL, DATED 3/05/2009 2. PEOPLE COUNT AND HEAT OUTPUT ASSUMED BY MCKINSTRY 3. LIGHTING HEAT GAIN IS ASSUMED AT 1 W /SF 4. OSA QUANTITY BASE ON 20 CFM /PERSON 5. 2006 WSEC, EXEMPTION 1 APPLIES, EQUIPMENT EFFIECEINCY RREATER THAN 10 %OF THE EFFICIENCY LISTED IN TABLE 14-1B 30389 • • EVIEWED FO ODE COMP LIANCE APPROV MAY 0 4 2009 RECEIVED CITY OF TUKWILA APR 16 2009 PERMIT CENTER PROVIDENCE OFFICE SPACE SDC 5203 3355 S. 120th Place Tukwilla, WA 98168 REGISTRATION: REVISIONS: SHEET TITLE: HVAC BASIS OF DESIGN & SCHEDULES SHEET NUMBER: instry le Of Your Building 04/14/09 PERMIT SEE . McKINSTRY DIVISION: ENGINEERING DESIGNED BY ' T. MARINO DAGGETC EXPIRES: 9 -21 -09 DRAWN BY: CHECKED BY: B. JOB NUMBER: DATE: 04 -10 -09 SCALE: SEE DRAWING M7.0 SEATTLE: 5005 3RD AVENUE S PO BOX. 24567 SEATTLE, WA 98124 1- 800 - 669 -6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503- 331 -0234 www.mckinstry.com