Loading...
HomeMy WebLinkAboutPermit M09-054 - SUBWAYSUBWAY 3725 S 144 ST M09 -054 Parcel No.: 0040000115 Address: Suite No: 3725 S 144 ST TUKW Tenant: Name: SUBWAY Address: 3725 S 144 ST , TUKWILA WA Citytif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL, PERMIT Owner: Name: SILVERDALE - TUKWILA LLC ET A Address: 9777 WILSHIRE BLVD #1009 , BEVERELY HILLS CA Contact Person: Name: ANDRE MROZ Address: 12745 39 AVE NE , SEATTLE WA Contractor: Name: TAMARAC CONSTRUCTION Address: 12745 39 AV NE , SEATTLE WA Contractor License No: TAMARC *991KB DESCRIPTION OF WORK: INSTALL NORLAKE 6' X 6' FREEZER & COOLER. NO FREON WORK Value of Mechanical: $500.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: I MC -10/06 EQUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * * continued on next page ** M09 -054 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 - 669 -9763 Phone: 206 669 -9753 Expiration Date: 05/27/2011 M09 -054 06/01/2009 11/28/2009 Fees Collected: $138.75 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood /Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 06 -01 -2009 Permit Center Authorized Signature: doc: IMC-10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us (ka Permit Number: M09 -054 Issue Date: 06/01/2009 Permit Expires On: 11/28/2009 Date: 69— (`O I I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. am authorized to sign and obtain this mechanical permit. Signature: i .a... Date: 4X/137 Print Name: // ZA/di ti.- 2 1.-h�� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -054 Printed: 06 -01 -2009 Parcel No.: 0040000115 Address: 3725 S 144 ST TUKW Suite No: Tenant: SUBWAY 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M09 -054 Status: ISSUED Applied Date: 05/22/2009 Issue Date: 06/01/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4)(Extend sprinkler protection td the walk -in cooler /freezer.) 12: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 15: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. M09 -054 Printed: 06 -01 -2009 doc: Cond -10/06 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** M09 -054 Printed: 06 -01 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Date: / /o; Print Name: 191i adt9 L-- 1,41422- doc: Cond -10/06 M09 -054 ordinances governing or local laws regulating Printed: 06 -01 -2009 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 0 (I WOO- 7 1 ,' J Site Address: ?725 5 144 ST . T /K/cl /Li' Suite Number: Floor: Tenant Name: 5 � ic/19 New Tenant: jid Yes ❑ .. No Property Owners Name: L me: S /LI' R2 .4Le - 7LJ /z.A7 LLB' ET A 4 Mailing Address: 777 P 731!/)) # /4 i tf Li' t 1 a c-.4 90 -212, City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be i sued Name: /JNDI.22 /41M2t9Z In Day Telephone: Mailing Address: 1211() 3 R - ik 0-t't= 5e/4T72 4/4 qr/ .s City State Zip E -Mail Address: Jj7 HA M( , 4 Q L— • /� • L oM Fax Number: MECHANICAL CONTRACTOR INFORMATION Company Name: / nit-JR /4e e-ONr Mailing Address: /272 31M 1/6 Ni% _57 4/6 /�/— City State p Zip Day Telephone:1.06 66 9 976 6 Contact Person: 2NN/2i5 / 1RO2 E -Mail Address: >ZEJY4/1 1 1e , (V/f MECHANICAL PERMIT APPLICATION Mechanical Permit No. ( o9_ 0 5 i Project No. (2 i' &JJtL t ii.St" L'19% Q 4) K Fax Number: n Contractor Registration Number: AN/4 PIE 4 `t / K& Expiration Date: 0�', .7'' 2 0 / ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: State Zip City Day Telephone: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:Wpplications\Forms- Applications On Line \2009 Applications \1.2009 - Mechanical Permit Application.doc Revised: 1.2009 bh State Zip Page \ of 2 Unit Type: Qty Unit Type: Qty Unit Type:. Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig /Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator— Comm /Ind ,�'^DO `= Valuation of Project (contractor's bid price): $ ,/ Scope of Work (please provide detailed information): FREE^ .Ed2 , NO PAZ, & Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric 'JE Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: - 19/`7'd4 2/41 e, er 5'l 7,e4 -/ Date: - `7 Print Name: ,4/YAJ ROZ Day Telephone 9 9/65 Mailing Address: /27:46 'W � / 4 1 ` . N L 5 - 72 G e / 9 / Cit State Zip Date Application Expires: fi I J . Date Application Accepted: H:\Applications\Forms- Applications On Line \2009 Applications \1-2009 - Mechanical Permit Application. doc Revised. 1 -2009 bh Staff Initials: I � Page 2 of 2 Parcel No.: 0040000115 Address: 3725 S 144 ST TUKW Suite No: Applicant: SUBWAY Receipt No.: R09 -00762 Initials: User ID: WER 1655 Payee: TAMARAC CONSTRUCTION • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tulcwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3061 138.75 Authorization No. ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Account Code Current Pmts 000.322.102.00.0 111.00 000/345.830 27.75 Total: $138.75 Permit Number: M09 -054 Status: PENDING Applied Date: 05/22/2009 Issue Date: Payment Amount: $138.75 Payment Date: 05/22/2009 08:37 AM Balance: $0.00 PAY ENT ECEIVED doc: Receiot -06 Printed: 05 -22 -2009 Project: S .1 L. t,"J h Type of Inspect n: i C. f. A v Address: -� Date Called: Special Instructions: Date Wanted:, la J — 07 —a.m... p.m. Requester: Phone No: r Z ._ nt43q - c)s INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ; t� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 12 f Approved per applicable codes. 0 Corrections required prior to approval. g COMMENTS: M ( 1. [ r R AJ /U / () .9R.l ` -- La ,M T r Inspector: Date: G-16-07 U $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: t TYPe,pf Inspection tee n Addre Address: .3'72.5 S. 144 ST Date Called': F S`Np �� Special InsInstructions: �eDA cco i( �� f / Date Wanted: ? . / . o � a.m p.m. Requester: Phone Nod — (06 q ' e1/76 coq- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. / CITY OF TUKWILA BUILDING DIVISION P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Approved per applicable codes. Corrections required prior to approval. 7 COMMENTS: Date: 3 7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project: _ 6 ' 0 ew a i ,, i Sprinklers: y Type of Inspection: ,E /i i ? �7 / E Address: 1,2C S Suite #: NY LI Contact Person: 6/Am/ M/ ‘44 1 0 ) Special Instructions: Phone No.: 25; - 3;v' SZ/ -72 Monitor: Needs Shift Inspection: I Sprinklers: y Fire Alarm: /1 Hood & Duct: n/ Monitor: Pre -Fire: Permits: Occupancy Type: B (k < so occ ) I I proved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 Word/Inspection Record Form.Doc 1/13/06 206 - 575 -4407 I I Corrections required prior to approval. COMMENTS: Air 4 ft <Pa 1 - — O /C -- ors WORKE70 o,, (,r#02-9 - r. LT • !SIC. 1/01:- -- o tK Inspector: Date: 6// Hrs.: / rs.. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 ACTIVITY NUMBER: M09 -054 PROJECT NAME: SUBWAY SITE ADDRESS: 3725 S 144 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DATE: 05 -22 -09 Revision # After Permit Issued DEPARTMENTS: - )- -7 4•. dn Division Public Works u DETERMINATION OF (Tues., Thurs.) Complete Comments: TUES/THURS ROI6TING: Please Route REVIEWER'S INITIALS: Documents /routing slip.doc 2 -28 -02 �,� . JOOR!H'Y PLAN REVIEW /ROUTING SLIP 5'81 Fire Prevention ioNi Structural Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: LI DATE: DATE: Planning Division DUE DATE: 05-26-09 Not Applicable No further Review Required DUE DATE: 06-23-09 Not Approved (attach comments) n n Permit Coordinator Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: LI Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW El Staff Initials: Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 CBIC INRSD0214 05/02/2006 05/02/2010 ARCHIVED $1,000,000.00 04/09/2009 4 CBIC INRSD0214 05/02/2005 05/02/2006 $1,000,000.00 05/27/2005 3 CBIC INRSD0214 05/02/2004 05/02/2005 $1,000,000.00 04/22/2004 2 CBIC INRSD0214 04/24/2003 05/02/2004 $10,000,000.00 04/28/2003 1 CBIC INSSD0214 05/02/2001 05/02/200310/07 /2002 $1,000,000.00 05/02/2001 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 CBIC SD0214 05/02/2002 Until Cancelled ARCHIVED $12,000.00 05/03/2002 1 CBIC SD0214 05/02/2001 05/02/2002 $6,000.00 05/02/2001 v` M" License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TAMARC *099DH TAMARAC CONSTRUCTION CONSTRUCTION CONTRACTOR GENERAL UNUSED 3/8/1991 3/6/1997 ARCHIVED Name Role Effective Date Expiration Date MROZ, ANDRZEJ OWNER 05/02/2001 Untitled Page • • General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company TAMARAC CONSTRUCTION 2063627917 12745 39TH AVE NE SEATTLE WA 98125 KING Individual UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602117770 ACTIVE TAMARC *991 KB CONSTRUCTION CONTRACTOR 5/2/2001 5/27/2011 GENERAL UNUSED s Owner Information Information formation https://fortress.wa.gov/lni/bbip/Detail.aspx Page 1 of I 06/01/2009 FURNITURE AND EQ UIPUI F'NT L EG END # ITEM MANUFACTURER ' FR OM 1 QTY. DESCRIPTION CUSTOMER AREA 1 BOOTH SEATING PLYMOLD DAI 2 ( 1 ) 4- SEATER ( ) 2- S EATER ( ) 3- SEATER ( )2 -SEAT H ANDICA P ( 1 ) 4 -SEAT HANDICAP. ( X ) CONTOUR ( ) COLORCOURT, BENCH AND TABLE TOP (WITH BLACK DURA -EDGE) COLOR: FONT HILL PEAR LAMINATE. 4B 20" X 24" TABLE PLYMOLD DAI 18 30" HIGH W/ FREESTANDING 22" X 22" CROSS BASE. FONT HILL PEAR LAMINATE WITH BLACK DURA EDGE, 5A 30" ROUND BAR HEIGHT TABLE PLYMOLD DAI 3 42" HIGH W/ FREESTANDING 30" X 30" CROSS BASE. FONT HILL PEAR LAMINATE WITH BLACK DURA EDGE. 6A CHAIR PLYMOLD DAI 38 QUEST CHAIR W/ UPHOLSTERED SEAT OR DUR —A —SEAT TO BE ORDERED IN THE FOLLOWING COLORS CROCUS, SPICE AND SLATE. FRAME COLOR IS BLACK WRINKLE. 6B BAR HEIGHT STOOL PLYMOLD DAI 9 QUEST STOOL Wf UPHOLSTERED SEAT OR DUR —A —SEAT TO BE ORDERED IN THE FOLLOWING COLORS: CROCUS, SPICE AND SLATE. FRAME COLO R IS BLACK WRINKLE 8A TRASH RECEPTACLE PLYMOLD DAI 1 SINGLE HOLE TRASH UNIT. 25" X 25" BLACK DURA EDGE TRASH RECEPTICLE W /FONT HILL PEAR LAMINATE FINISH. 9 SODA FOUNTAIN CORNELIUS DAI 1 DEDICATED 115V, 20 AMP DUPLEX OUTLET (NEMA 5 -20R) W /IN 3 FEET, 3 INCH OR LARGER FLOOR DRAIN W /IN 3 FEET (EQUIPMENT INSTALLED BY COKE). 10 BEVERAGE DESTINATION CENTER DUKE MANUFACTURING DAI 1 ( X )RH ( )LH BEVERAGE PLACEMENT ( )48" ( )60" ( X )72" ( )84" ( )96" ( )108" ( )120 ". STAINLESS STEEL TOP. FONT HILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 11 RED NEON "OPEN" SIGN ZEON CORD, /HINSON DISPLAY/NEON ()LASS WORKS DAI /G.C. 1 SEE MANUFACTURER FOR SPECS. 220V. INSTALLED BY G.C. 13A WALL ART — VERTICAL SUNGLO FABRICS DAI 3 23" X 50" WALL HUNG PRINT(S) ON STYRENE —FACED FOAMBOARD FRAMED IN BLACK METAL. MOUNTING HARDWARE INCLUDED, EIGHT DIFFERENT PRINT IMAGES AVAILABLE. 138 14 WALL ART — SQUARE CHIP RACK SUNGLO FABRICS FRITO —LAY TRUE DAI DAI DAI 2 1 1 26" X 26" WALL HUNG PRINT 5) COLOR PHOTOS DOUBLE MATTED IN A BLACK WOODEN FRAME. MOUNTING HARDWARE INCLUDED. EIGHT DIFFERENT PRINT IMAGES AVAILABLE. ( )44 "W X 16 3/8 "D X 68 "H ( )44 "W X 163/8 "D X 54 "H (X)33 1/4 "W X 16 3 /8 "D X 68 "H FLOOR RACKS. / ( )24 "W X 12 "D X 22 "H ( )36 "W X 12 D X 22 "H COUNTERTOP RACKS. THROUGH LOCAL DIST. ( X )1 DOOR FLOOR MODEL ( )2 DOOR FLOOR MODEL. DEDICATED 115V, 15 AMP DUPLEX OUTLET (NEMA 5 -15R) W /IN 6 FEET. 15 DISPLAY REFRIGERATOR 16 WALL PLANT GRACE DESIGNS DAI 1 WALL HUNG SILK PLANT. MOUNTING BRACKET TO BE HUNG 15" BELOW THE TOP OF THE UPPER DECORATIVE MOLDING (REFER TO TUSCANY II BACK —UP SHEET #1) SOLID CORE HARDWOOD DOOR (SLAB OR PANEL CONSTRUCTION) STAIN MINWAX #235 CHERRY & POLYURETHANE W/ MINWAX FAST DRYING SATIN. METAL FRAME (PAINT SHERV1N IMAMS #SW6356 COPPER MOUNTAIN) LEVER HANDLE, INSTALLED BY GC. 17 INTERIOR DOOR LOCAL G.C. 1 SERVICE AREA 19 FRONT COUNTER DUKE MANUFACTURING DAI 1 TOTAL LENGTH _1T =2'_ ( X )LH ( }RH 25 "_HOT FOOD UNIT ( 2 ) 60 "COLD PAN UNIT _.61 "GASH UNIT. NIA HOT FOOD EXTENSION NL&CASH EXTENSION N/A BEVERAGE EXTENSION. INSTALLED BY G.C. ULS APPROVED. ELECTRICAL CONNECTIONS AND WIRING TO LOCAL AND STATE CODE REQUIREMENTS AS DETERMINED BY G.C. OR ELECTRICIAN. 21 COOKIE DISPLAY CASE ADVANCED DISPLAYS IN PLASTICS, INC DAI 1 DISPLAY CASE ON TOP OF SUB —WRAP AND NAPKIN RISER. MADE OF CLEAR ACRYLIC. 23 SAFE C.S.S. /TIDEL DAI 1 ( )T1ME LOCK ( X )QUICK DROP ( ) TIDEL TACC. INSTALLED BY G.C. IN SERVICE AREA. 24 SUBSHOP 2000 P.O.S. MICROS SYSTEMS /DELL /SUBTOTAL DAI 1 PC BASED POINT OF SALE SYSTEM. REQUIRES DEDICATED POWER SOURCE WITH ISOLATED GROUND TO BREAKER. 25 MICROWAVE AMANA /SHARP DAI 1 *5 -20R OUTLET REQUIRED. 1200 WATT, 120V /60HZ /1PH, 20 AMP CIRCUIT. DEDICATED CIRCUIT REQUIRED. 27 BREAD OVEN NU —VU DAI 1 NU —VU. DEDICATED CIRCUIT REQUIRED. DIRECT WIRED. INSTALLED BY G.C. NSF APPROVED. *1/4" WATERLINE IS REQUIRED. 28A ENCLOSED BREAD CABINET NU —VU DAI 1 NU —VU. INSTALLED BY G.C. NSF APPROVED. 28COPEN AIR COOLING RACK LOCKWOOD DAI 1 ( )HALF RACK -30 "H ( X)FULL RACK -64 "H. 21 1/4 " "W x 26 1/2 "D. INSTALLED BY G.C. NSF APPROVED. 29 MENUBOARD VGS / TRANSLITE SONOMA DAI DAI 4 1 MENUBOARD: ( 4 )2' X 4' ( )2' X 2'. LIGHT FIXTURES: ( )2 ( )4' ( )8' ( 1 )16' MOUNT TO TOP OF MENUBOARD. SINGLE OUTLET REQUIRED. INSTALLED BY G.C. SELF — CLOSING, PREFRAMED 8c PREFINISHED OR SEE BACK —UP SHEETS FOR CONSTRUCTION SPECS. FONTHILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 30 COUNTER ENTRANCE PLYMOLD /DUKE MFG. 31 BACK COUNTER W/ HAND SINK DUKE MANUFACTURING DAI 1 ( )RH ( X )LH ( )CENTER HAND SINK. ( )24" ( )36" ( X )48" ( )60" ( )72" LENGTH. STAINLESS STEEL TOP. FONT HILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 33 REFRIGERATED BACK COUNTER DUKE MANUFACTURING DAI 1 ( X )48" LENGTH. ( LENGTH. BACK COUNTER WITH UNDER — COUNTER REFRIGERATOR. STAINLESS STEEL TOP. FONT HILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 34 RAPID COOK OVEN TURBOCHEF /MERRYCHEF DAI 1 ( X )TURBOCHEF ( )MERRYCHEF MICROWAVE /CONVECTION OVEN. REFER TO TUSCANY II BACK —UP SHEET #4 FOR FURTHER SPECIFICATIONS. BACKROOM AREA 36 SINK DUKE MANUFACTURING DAI 1 ( 3 )COMPARTMENT(S) ( 2 )DRAINBOARD(S). ( X )18" ( )24" DRAINBOARD SIZE. INSTALLED BY G.C. ULS APPROVED. 37 MOP SINK LOCALLY SOURCED G.G. G.C. 1 1 FLOOR LEVEL SINK. 2' X 2' (PREFERRED). ACQUIRE LOCALLY. INSTALLED BY G.C. ACQUIRE LOCALLY. INSTALLED BY G.C. 3 8 HOT WATER TANK LOCALLY SOURCED 39 S.S. WORKTABLE DUKE MANUFACTURING DAI 1 ( )24" ( )36" ( )48" ( )60" ( X )72" ( )84" ( )96" ( )108" ( )120" X 30 ". ( X )W/ GALVANIZED UNDERSHELF ( )WITHOUT UNDERSHELF. 40 WALL SHELF INTER METRO DAI 3 SUPER ERECTA BRITE. EPDXY COATED. WALL MOUNTED SHELVES, AVAILABLE IN VARIOUS SIZES. INSTALLED BY G.C. 41 VEGETABLE SINK DUKE MANUFACTURING DAI 1 ( 1 )COMPARTMENT(S) ( 1 )DRAINBOARD(S). ( )18" ( )24" DRAINBOARD SIZE. INSTALLED BY G.C. ULS APPROVED. 42 HAND SINK DUKE MANUFACTURING / LOCAL DAI /G.C. 1 WALL MOUNTED, 10" X 14" X 6 ", OR SEE OWNER FOR SPECS. SUBJECT TO HEALTH CODE APPROVAL. 43 CLEANING PRODUCT RACK SSDC DAI 1 DISPENSING STATION FOR CLEANING PRODUCTS. 45 NEMCO EASY — SLICER NEMCO, INC. DAI 1 MANUAL SLICER MOUNTED ON STAINLESS STEEL TABLE TOP. NSF APPROVED. 46 RETARDER CABINET LOCKWOOD DAI 1 ( X )WALK —IN ( )REACH —IN . NSF APPROVED. 47 REFRIGERATOR NORLAKE DAI 1 ( )8' X 6' ( )6' X 8' ( X )6' X .6' ( )5' X 6' ( )4' X 6' (J3 DOOR ( )2 DOOR ( )1' DOOR ( OTHER__ SELF — EVAPORATING. DIRECT WIRED. INSTALLED BY G.C. NSF APPROVED. 48 FREEZER., NOR LAICE,... DAI 1 ( )8' X 6' ( )6' X 8' ( X 6'' " ( ) X 6' )4 ( )3 D OOR ( )2 DOOR ( )1 DOO ( )O THER_ SELF— EVAPORATING. DIRECT WIRED INSTALLED BY G.C. NSF APPROVED 49 STORAGE UNITS INTER METRO DAI LLI ( 1 )18" X 60" (3 )24" X 72 ". SUPER ERECTA BRITE. 50 SODA STORAGE COKE DAI DEDICATED 115V, 20 AMP DUPLEX OUTLET (NEMA 5 -20R) W /IN 3 FEET OF BIB RACK, 96 INCHES HIGH /WATER 1/2 INCH BALL VALVE SHUTOFF W /IN 3 FEET OF BIB RACK, 96 INCHES HIGH EQUIPMENT INSTALLED BY COKEL RECEIVER AND AMPLIFIER WITH THREE SPEAKERS MOUNTED AND PROFESSIONALLY WIRED IN CEILING. OPTIONAL SUBWAY® RADIO SERVICE. 51 STEREO SYSTEM SUBWAY® RADIO /LOCAL DAI /LOCAL DATE: JANUARY 7, 2008 DESIGNED BY: PETER SEELEY/ DAVE SURA DRAWN BY: PMD R IEW 10 D • SCALE: 1/4" 1 <OIr REVISION: I A8 �_Lva I!I UPGRADE TO "TUSCANY II" 80/GE/I. DECOR CHANGES 0wd I 60/6/l 111111111111111111111111111111111u1 IllllhIIIIIIHlr , • 1111111111111111 1111111111111111 /111111111111111 IIIIIIIIIIIIIIIII dIIIIIIIIIII111111111111111111111111 111111IIIIII111111111111111111111111 Illllllllllllllr , .1111111111111111 1111111111111111 11111111111111 111111111111111111rlhIIIIIlllllll111 111111111111111111111111111111111111 TYP. 4 8 TYP. ICE ON TOP 36" HIGH WALL MODEM LINE (REQUIRED) ABOVE 8 PANELS C� 44 0 ion 1] MOUNT ON SHELF HEADERWALL ©6' -8" A.F.F 1111111111111111111111111111 11 111 I I I 1 111 / ,!. M 111111111111 111111111111, 111111111111 ABOVE #38 WALL MOUN 111111111111111111IIIIu1111111111 1111111111111111111111111111111111 mu , .1111ulllllllll 111111111M11111111110111111111111111111111 111111111111111111111111111111 DIRECT WIRED 10' 9' -6" 17' -2" EXISTING RESTROOM ENTRANCE 3' -11" 3'0" X 6'8" 10" // 17' -6" 66' 12'- 30' -3" 8'-10" d- N � n - 2' -8 1/4" 1 11' -8" N N No changes shalt be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fee City Of lbkwila BUILDING DIVISION MO9- 05y NEW LOCATION GENERAL NOTES: REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 9 2009 City of Tukwila BUILDING DIVISION ■ FILE COPY Permit No.{,, Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and editions if ' acknowledged: RECEIVED MAY 22 am PERNIFT CENTER - CEILING HEIGHT IS 20' - ELECTRICAL OUTLET HEIGHTS MEASURED TO BOTTOM OF BOX. - ONE ELECTRICAL JUNCTION BOX TO BE LOCATED IN CEILING ABOVE EACH WINDOW. - STORE DESIGNED WITH CONTOUR SEATING. SHAWN ON PLAN AS SINGLES NOT GROUPS. - CUNO MODEL SW3 -PLUS WATER FILTRATION SYSTEM IS REQUIRED IN /,ILL NEW STORES THAT DISPENSE BEVERAGES. THE RECOMMENDED PLACEMENT FOR INSTALLATION IS MOUNTED TO SODA SYRUP RACK BY COCA -COLA. SECONDARY PLACEMENT OPTION IS MOUNTED ON THE BACKROOM WALL. THIRD INSTALLATION OPTION IS MOUNTING INSIDE THE FRONT BEVERAGE COUNTER WHEN SPACE LIMITATIONS OCCUR. REQUIRED: 1/2" INCOMING WATER LINE FEED WITH 1/2" BALL VALVE SHUTOFF AND . FPT CONNECTION. MINIMUM 110 VOLT, 20 AMP ELECTRICAL SERVICE TO SUPPORT THE CARBONATOR AND WATER BOOSTER (MUST BE DEDICATED CIRCUIT). - SMARTCURVE STAND (MFR. DISPLAY -BOX) REQUIRED IN CUSTOMER AREA AT POINT OF ORDER (PREFERRED PLACEMENT). 21 3/4" X 13 1/8" BASE, 56" (WITHOUT HEADER) OVERALL HEIGHT. - BASKET STYLE SECONDARY CHIP RACK REQUIRED IN CUSTOMER AREA AT POINT OF ORDER (PREFERRED PLACEMENT). - EXIT LIGHTS INSTALLED BY G.C. PER LOCAL CODE. - EMERGENCY LIGHTS INSTALLED BY C.C. PER LOCAL CODE. - EXTINGUISHERS, SMOKE AND FIRE DETECTION SYSTEMS INSTALLED BY G.C. PER LOCAL CODE. - LABOR & MATERIAL SUPPLIED BY C.C. UNLESS OTHERWISE NOTED. - ALL DIMENSIONS TO BE VERIFIED BY G.C. ON SITE. - DECOR SPECIFICATIONS ARE TO BE SUBWAY'S "TUSCANY II" SCHEME. - REFRIGERATOR AND FREEZER MUST BE ADEQUATELY VENTILATED. REFER TO MANUFACTURER FOR DETAILS. THE D.A. MUST CONFIRM THAT SUBWAY WILL SHARE OR BE PROVIDED SPACE FOR THE FOLLOWING ITEMS: RESTROOM ACCESS. VISIBILITY INTO BACKROOM THROUGH GLASS MUST BE OBSCURED. EXISTING FLOOR FINISH TO REMAIN. EXISTING CEILING AND FIXTURES TO REMAIN. STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ( "DAI ") DIB /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND /OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAI'S AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB -CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAI'S STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. Efi z Lu Q J . cr\ Ct E 0 0 -J 0 W W SHEET #: 1 of 2 ©2008 DOCTORS ASSOCIATES, INC. SUBWAY* WORLD HEADQUARTERS 325 BIC DRIVE (203) 877-4281 MILFORD, CT 06461 (800) 888-4848 STORE #42522 SIZE INLET/ OUTLET SIZE FLOW RATE G.P.M. [L.P.M.] 0 99! I CAPACITY 115/60/1 APPROX. WT. LBS. [KG] 22.5 DIMENSIONS IN INCHES [ mm] WATER GAL. [L] GREASE LBS. [KG] Li C 208-230/60/1 8,3 C/E I �I ILL 1 N- F G 100* 2 [50] 4 15 3 11 8 4 42 19 10 254 7 1 4 184 20 3 8 518 9 7 8 251 200* 7 26 5 19 14 6 53 24 11 1 4 286 8 1 8 206 11 7 8 302 300* 10 38 6 23 20 9 66 30 11 3 4 298 8 1 4 210 25 1 8 638 14 356 400* 3 [75] 15 57 10 38 30 14 83 38 13 3 8 340 9 3 8 238 27 1 8 689 16 3 4 425 500 20 76 16 60 40 18 99 45 15 381 11 3 4 298 30 762 17 1 4 438 600 25 94 21 79 50 23 124 56 17 432 12 1 2 318 32 1 4 819 19 7/8 505 700 35 132 30 113 70 32 151 68 18 3 4 476 14 1 4 362 34 1 8 867 800 50 189 40 151 100 45 180 82 21 1 2 546 16 406 36 914 24 1 2 622 MODEL # L- - - - -- 0 99! I Ieaf 115/60/1 8.6 22.5 I [ L 115/60/1 1 I D Li . 208-230/60/1 8,3 ®C I I I J- I �I ILL 1 N- 115/60/1 , MODEL # VOLTS /HZ /PH L - - 0 99! I NR241SSS/0 115/60/1 8.6 22.5 I [ L 115/60/1 10,7 48.8 NR803SSS /8 208-230/60/1 8,3 75.0 NF241SSS /0 115/60/1 MODEL # VOLTS /HZ /PH AMPS, IN CU. FT. NR241SSS/0 115/60/1 8.6 22.5 NR522SSS /0 115/60/1 10,7 48.8 NR803SSS /8 208-230/60/1 8,3 75.0 NF241SSS /0 115/60/1 12 22.5 NF522SSS /0 115/60/1 12.4 48.8 NF803SSS /8 208 - 230/60/1 7.8 75.0 DATE: 10 - 31 - 0$ DESIGNED BY: PATRICK ROSE DRAWN BY: PMR REVIEWED BY: PMR SCALE: NOT TO SCALE TO BOTTOM OF HEADER -STD. SERIES: 6'7 1/2" (201.9cm) -74 SERIES: 7'4 1/8" (223,8cm) -77 SERIES: 7'7 1/2" (232.4cm) -78 SERIES: 7'8 1/2" (232.4cm) 2 3/4" - 45 SERIES: 6'0" (182.9cm) - STD. SERIES: 6'7" (200.7cm) - 74 SERIES: 73 5/8" (222.6cm) - 77 SERIES: 7'7" (231.1cm) -78 SERIES: 7'8" (231.1cm) NOTE: KLB = REFRIGERATOR. KLF = FREEZER. MODEL # KLB45 -CX -SUB KLB46 -CX -SUB KLB56 -CX -SUB KLB66 -CX -SUB KLB68 -CX -SUB KLB683 -CX -SUB KLB7446 -CX -SUB KLB7466 -CX -SUB KLB7468 -CX -SUB KLB74683 -CX -SUB KLB7746-CX- SUB KLB7756 -CX -SUB KLB7766 -CX -SUB KLB7768 -CX -SUB KLB77683 -CX -SUB KLF45 -Cx KLF46 -Cx KLF56 -Cx NORLAKE WALK -IN 5' X 6', 6' X 6', 6' X 8' OR 8' X 6' REFRIGERATOR OR FREEZER WITH FACE THROUGH WALL TYPICAL ELEVATION DETAIL KLF66 -CX * KLF68 -CX * KLF683 -CX KLF7746 -CX * KLF7756 -Cx KLF7766 -CX KLF7768 -CX KLF77683 -CX KLF7846 -CX * KLF7856 -Cx KLF7866 -CX KLF7868 -CX KLF78683 -CX 1' afiir Ns i mitdrii i[ k THIS DRAWING APPLIES TO MODELS KLB AND KLF 56, 66, 68 AND 683 IN STD, 74, 77 AND 78 SERIES. REFER TO NORLAKE KOLD LOCKER SERIES REFRIGERATOR AND FREEZER DRAWINGS AND TABLE BELOW FOR EXACT DIMENSIONS OF UNITS. A 4' (121.9cm) 4' (121.9cm) 5' (152.4cm) 6' (182.9cm) 8' (243.8cm) 6' (182.9cm) 4' (121,9cm) 6' (182.9cm) 8 (243.8cm) 6' (182.9cm) 4" (121.9cm) 5 (152.4cm) 6' (182.9cm) 4 (121.9cm) (152.4cm) 6 (182.9cm) 8 ' (243.8cm) 4' (121.9cm) 5' (152.4cm) 6' (182.9cm) 8' (243.8cm) 6' (182.9cm) 4' (121.9cm) OPENING WITH GRILL OR LOUVRES (MIN. SIZE 15 "H. X 26 "W.) IN HEADER WALL RECOMMENDED FOR VENTILATION OF ROOF MOUNTED COMPRESSOR. C]r - 1=L 11 - =I - 'fir .7I - - E51 = - 11=11L. 1[-7= I, PER DIMENSIONED FLOOR PLAN F B 5' (152.4cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 8' (243.8cm) 6' (182.9cm) 6' (182.9em) 6 (182.9cm) 8' (243.8cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 8' 6' (243.8cm) (1829cm) (182.9cm) (243.8cm) 4 ' 5' (121.9cm) (152.4cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' 8' (182.9cm) (243.8cm) 6' (182.9cm) 6' (182,9cm) 6' (182.9cm) 6' (182.9cm) 8' (243.8cm) 6' (182.9cm) 5' 6' (152.4cm) (182.9cm) 6' 6' (182.9cm) (182.9cm) 8' 6' (243.8cm) (182.9cm) 6' 8' (182.9cm) (243.8cm) A SIDE VIEW C 26" 26" 26" 26" t 26" (66cm) 26" (66cm) 26" (66cm) (66cm) m) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) (66cm (66cm) 26" (66cm) 26 (66cm) 26" (66cm) (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) D k L. -- j MODEL KLF66 or KLC66 SHOWN ABOVE 59" (149.9cm) 66" (167.6cm) (167 6cm) 66" (167.6cm) 66" (167.6cm) 66" (167.6em) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) (149,9cm) (1676cm) 66" (167.6cm) 66" (167.6cm) 66" (167.6cm) 66" (167.6cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) E 26" (66cm 26" (66cm (66cm) m) 37" (94cm) 37" (94cm) 37" (94cm) 26" (66cm) 37" (94cm) 37" (94cm) 37" (94cm) 26" (66cm) (66cm) m) 37 ". (94cm) 37" (94cm) 37" (94cm) 39" (99.1cm) 39" (99.1cm) 39" (99.1cm) 39" (99.1cm) 36 1/2" (92.7cm) 36 1/2" (92.7cm) 3s „ (99.1cm) 36 1/2" (92.7cm) 39" (99.1cm) 36 1/2" (92.7cm) 36 1/2" (92.7cm) 39" (99.1cm) 36 1/2" (92.7em) 39 (99.1cm) 36 1/2" (92.7em) 36 1/2" (92.7cm) F 44 1/2" (113cm) 44 1/2" (113cm) 44 1/2" (113cm) 48 1/4" (122.6cm) 48 1/4" (122.6cm) 48 1/4" (122.6cm) 44 1/2" (113crri) 48 1/4" (122.6cm) 48 1 /4" (122.6cm) cm) 48 1/4" (122.6cm) 44 1/2" (113cm) 44 1/2" (113cm) 48 1/4" (122.6cm) 48 1/4" (122.6cm) 48 1/4" (122.6cm) 44 1/2" (113cm) 44 1/2" (113cm) 48 1/4" (122.6cm) 48 1/4" (122.6cm) 59" (149,9cm) 59" (149.9cm) 48 1/4" (122.6cm) 59" (149,9cm) 48 1/4" (122,6em) 59" (149.9cm) 59 „ (149.9cm) 48 1/4" (122.6cm) 59" (149.9cm) 48 1/4" (122.6cm) 59" (149.9cm) 59" (149.9cm) NOTE: EACH DOOR SECTION REQUIRES SEPERATE 115/60/1 HOOK UP AND DRAWS 2.3 AMPS. *THESE SYSTEMS HAVE FAN MOTORS THAT REQUIRE SEPERATE 115/60/1 HOOK UP AND DRAW .75 AMPS. ABOVE SPECIFICATIONS FOR CEILING MOUNT SYSTEMS AND INDOOR USE ONLY. WALL MOUNT AND REMOTE COMPRESSORS AVAILABLE. SEE MANUFACTURER FOR DETAILS. ALL TO BE DIRECT WIRED. NSF APPROVED. UL LISTING I{E- 486142 (REPORT x{48). E.T.L. APPROVED. CSA FILE 18542 -24. BUTTERNUT BRICK TEXTURED WALL COVERING COVE BASE G 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7em) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 22 7/8" (58.1cm) 22 7/8" (58.1cm) 14 7/8" (37.7cm) 22 7/8" (58.1cm) 14 7/8" (37.7cm) 22 7/8" (58.1cm) 22 7/8" (58.1cm) 14 7/8" (37.7cm) 22 7/8" (58.1cm) 14 7/8" (37.7em) 22 7/8" (58.1cm) 22 7/8" (58.1cm) INTERIOR CU. FT. 77 105 137 168 231 231 123 196 270 270 123 137 196 270 270 77 105 137 168 231 231 123 137 196 270 270 113 149 184 256 256 TO BOTTOM OF HEADER -45 SERIES: 6'0 1/2" (184.2cm) -STD. SERIES: 6'7 1/2" (201.9cm) -74 SERIES: 7'4 1/8" (223.8cm) -77 SERIES: 7'7 1/2" (232.4cm) -78 SERIES: 7'8 1/2" (232.4cm) B FRONT VIEW VOLTS /HZ /PH 115/60/1 115/60/1 115/60/1 208 - 230/60/1 208 - 230/60/1 208 - 230/60/1 115/60/1 208 - 230/60/1 208- 230/60/1 208- 230/60/1 115/60/1 115/60/1 208 - 230/60/1 208 - 230/60/1 208 - 230/60/1 208 - 230/60/1 208- 230/60/1 208 - 230/60/1 208 - 230/60/1 208 - 230/60/1 208 - 230/60/1 208 - 230/60/1 208 - 230/60/1 208 - 230/60/1 208 - 230/60/1 208 - 230/60/1 208 - 230/60/1 208 - 230/60/1 208- 230/60/1 208 - 230/60/1 208 - 230/60/1 _ )C L 1 , PER DIMENSIONED FLOOR PLAN d i, THIS DRAWING APPLIES TO MODELS KLB AND KLF 45 AND 46 IN 45, STD, 74, 77 AND 78 SERIES. REFER TO NORLAKE KOLD LOCKER SERIES REFRIGERATOR AND FREEZER DRAWINGS AND TABLE BELOW FOR EXACT DIMENSIONS OF UNITS. NORLAKE WALK-IN 4'X5'OR4'X6' REFRIGERATOR OR FREEZER WITH FACE THROUGH WALL TYPICAL ELEVATION DETAIL MINIMUM CIRCUIT AMPS 14,2 14.2 14.2 10.5 11.9 11.9 14.2 11.9 11,9 11.9 14.2 14.2 10.5 11.9 11.9 13.4 13.4 DEFROST 13.4 13.4 DEFROST 13.4 13.4 DEFROST 13.4 13.4 DEFROST 8.8 10.8 DEFROST MANUFACTURER CLEARANCE SPECIFICATIONS: 8.8 10,8 DEFROST 13.4 13.4 DEFROST 8.8 10.8 DEFROST 13.4 13.4 DEFROST 8.8 10.8 DEFROST 8.8 10.8 DEFROST 13.4 13.4 DEFROST 8.8 10.8 DEFROST 13.4 13.4 DEFROST 8.8 10.8 DEFROST 8.8 10.8 DEFROST TOTAL SYSTEM AMPS 11.7 11.7 11.7 8.7 10 10 11.7 10 10 10 11.7 11.7 8.7 8.7 8.7 10.7 10.7 8.2 8.2 9.1 9.1 8.2 9.1 8,2 9.1 9.1 8.2 9.1 8.2 9,1 9.1 DO NOT STORE BOXES ON THE TOP OF COOLER OR FREEZER. STORED OBJECTS WILL OBSTRUCT AIR FLOW C 0 AND CAUSE VENTILATION PROBLEMS FOR THE REFRIGERATION SYSTEMS. 24" CLEARANCE IS RECOMMENDED FROM TOP OF ROOF MOUNTED CAPSULE PAK REFRIGERATION SYSTEM TO CEILING FOR SERVICE PUROPOSES (6" MINIMUM). E MAXIMUM FUSE SIZE 20 20 20 15 15 15 20 15 15 15 20 20 15 15 15 20 20 15 15 15 15 15 15 15 15 15 15 15 15 15 15 NORLAKE KOLD LOCKER SERIES REFRIGERATOR AND FREEZER CUT -OUT IN HEADER WALL FOR ROOF MOUNTED COMPRESSOR. REFER TO NORLAKE KOLD LOCKER SERIES TABLE BELOW FOR DIMENSIONS. NOTE: ADD MIN. 1/2" [1.3cm] TO 'E' DIMENSION FOR ADEQUATE CLEARANCE. =3= [ i E 0 to P 1 l J ■MI 0_ F- J p Z � 2 oL d o L E O co N M BUTTERNUT BRICK TEXTURED WALL COVERING J I -r -COVE BASE o_ o o ° rr= o oo 0 L69. 'c TEFP E r B FRONT VIEW MODELS KLB683 AND KLF683 (STD, 77 & 78) SHOWN ABOVE I , 22 -1/4'' y [56.5cm] "I MODEL: CA33 -RR12 ALUMINUM WELDED CONSTRUCTION HOLDS 12 FULL SIZE PANS (18 X 26 ") OR 24 HALF SIZE PANS (13" X 18 ") NSF APPROVED LOCKWOOD DECK RETARDER 22-1/4' [56.5cm] L6J.9CmP MODEL: CA27 -RR12 ALUMINUM WELDED CONSTRUCTION HOLDS 12 FULL SIZE PANS (18" X 26 ") OR 24 HALF SIZE PANS (13" X 18 ") NSF APPROVED LOCKWOOD REACH -IN RETARDER OPENING WITH GRILL OR LOUVERS (MIN. SIZE 15" H X 26" W) IN HEADER WALL RECOMMENDED FOR VENTILATION OF ROOF MOUNTED COMPRESSOR. 12" CLEARANCE IS RECOMMENDED ON BOTH SIDES OF THE WALL MOUNTED CAPSULE PAK FOR PROPER AIR FLOW LEFT END (N E 0 [0 QD (0 MODEL NR803SSS /8 OR NF803SSS /8 SHOWN 18" TYP. [45.7cm] [209.6cm] (2 DOOR NR482/NF482 - 55" c139,7cm]) ( 1 DOOR NR241/NF241 - 27 1/2' [69.9cm]) 4 84" 82 1/2" [ 213.4cm ] 16" TYP. [40.6cm] PLAN VIEW ALL SYSTEMS - CORD & PLUG SUPPLIED NSF APPROVED UL LISTING #SA -3931 CSA LISTING 18542 -23 NORLAKE REFRIGERATOR / FREEZER ELE fATION THREE COMPARTMENT SINK WITH TWO 18" DRAINBOARDS SHOWN ABOVE. AVAILABLE WITH ONE, TWO, THREE OR FOUR COMPARTMENTS AND ZERO, ONE OR TWO 18 "[45.7cm], 24 "[61cm] OR 30' "[76.2cm] DRAINBOARDS. THREE COMPARTMENT CORNER SINKS ALSO AVAILABLE. 1/2" NPT WATER LINES. 2" DRAINS. UL AND C -ILL LISTED. DUKE MANUFACTURING STAINLESS STEEL SINK c 0 Fi rn E 0 N un u [41.1cm] 21 1/2" [54.6cm] DEPTH 17 1/2 "J ` [44.4cm] MODEL: CA60 -RR25 HOLDS 25 HALF SIZE PANS (13" X 18 ") MODEL: CA76 -RR33 HOLDS 33 HALF SIZE PANS (13" X 18 ") *CA76 -RR33 TO BE USED WITH 77 SERIES REFRIGERATOR. ALUMINUM WELDED CONSTRUCTION NSF APPROVED LOCKWOOD RETARDER CABINET 36 "[91.4cm] TO 1207304.8cm] IN 12 "[30.5cm] INCREMENTS ELEVATION SEE BELOW AVAILABLE SIZES ARE: WIDTH: 14 ", 18 ", 21", 24" (35.6, 45.7, 53.3, 61 cm) LENGTH: 24', 30 ", 36 ", 42 ", 48 ", 60" AND 72" (61, 76.2, 91.4, 106.7, 121.9, 152.4, 182.9cm) 4 OR 5 TIER INTERMETRO SHELVING SYSTEMS WITH GALVANIZED UNDERSHELF TABLES 96" AND LARGER HAVE SIX LEGS DRAWERS ARE OPTIONAL NSF APPROVED RIGHT END DUKE STAINLESS STEEL WORKTABLE 1 24" [61.0cm] 30 [76.2cm] l ICE0520 CUBER ON B42 STORAGE BIN (374 LBS. STORAGE CAPACITY) AIR - COOLED OR WATER COOLED. ELECTRICAL SPEC FICATIONS: DIRECT WIRED PER CODE (3 WIRES) AIR - COOLED: 115V/60HZ/1PH 18.3 AMPS (20 MAX FUSE) 8441 BTUH. WATER - COOLED: 115V/60HZ/1PH 13.5 AMPS (15 MAX FUSE) 8356 BTUH. PLUMBING SPECIFICATIONS: 3/8" 10mm FPT WATER IN 3/4" 19mm FPT WATER OUT 3/4" 19mm FPT BIN DRAIN ): (WATER-CLED UNIT 3/8" (19mm) FPT CONDENSER 1/2" (13mm) FPT CONDENSER WATER OUT NSF/ UL APPROVED ICE -O -MA TI C ICE CUBER Q -420 CUBER ON S -420 BIN TYPE: AIR - COOLED, WATER - COOLED ELECTRICAL SPECIFICATIONS 115/60/1 20 AMP FUSE MIN. AIR - COOLED = 12.3 AMPS, WATER-COOLED = 11.4 AMPS WIRED DIRECT OR PER LOCAL CODE 220 - 240/50/1 ALSO AVAILABLE, SEE MANUFACTURER. PLUMBING SPECIFICATIONS 3/8" (0.95cm) F.P.T. INLET, 1/2" (1.27cm) F.P.T. DRAIN 3/4" (1.91cm) BIN DRAIN 3 8" (0.95cm) F.P.T. WATER CONDENSER INLET (WATER - COOLED UNIT) /2" (1.27cm) F.P.T. WATER CONDENSER OUTLET (WATER - COOLED UNIT) NSF APPROVED /U.L. #SA- 4027 /CSA LISTED MANITOWOC ICE CUBER MO 05 GREASE INTERCEPTOR MANUFACTURER: ZURN INDUSTRIES MODEL: Z1170 G = WIDTH OF BODY 24" [61.0em] ZURN GREASE INTERCEPTOR ICE -O -MATIC ICE CUBER ICE0400 CUBER (AIR - COOLED OR WATER - COOLED) ICE0500 CUBER (AIR - COOLED, WATER - COOLED OR REMOTE CONDENSER) ICE0606 CUBER (AIR - COOLED, WATER- COOLED OR REMOTE CONDENSER) ON B55 STORAGE BIN (556 LBS. STORAGE CAPACITY) ELECTRICAL SPECIFICATIONS: DIRECT WIRED PER CODE (3 WIRES) ICE0400: (AIR - COOLED) 115V /60HZ /1PH 14.4 AMPS (15 MAX FUSE) 8064 BTUH. (WATER- COOLED) 115V/60HZ/1PH 13.4 AMPS (20 MAX FUSE) 8388 BTUH. ICE0500: (AIR - COOLED) 115V/60HZ/1PH 19.9 AMPS (20 MAX FUSE) 10843 BTUH. (R (WATER-COOLED) 115V/60HZ/1PH 13.7 AMPS (20 MAXFUSE) 10242 BTUH. EMOTE) 115V /60HZ /1PH 18.7 AMPS (20 MAX FUSE) 10881 BTUH. ICE0606: (AIR - COOLED) 208- 230V/60HZ/1PH 12 AMPS (15 MAX FUSE)11538 BTUH. (WATER - COOLED) 208- 230V/60HZ/1PH 9.5 AMPS (15 MAX FUSE) 11473 BTUH. (REMOTE) 208- 230V/60HZ/1PH 13 AMPS (15 MAX FUSE) 12269 BTUH. PLUMBING SPECIFICATIONS: 3/8" 10mm) FPT WATER IN 3/4" 1 FPT WATER OUT 3/4" 19mm) FPT BIN DRAIN (WATER - COOLED UNIT CONDENSER LINES): 3/8" (19mm) FPT CONDENSER WATER IN 1/2" (13mm) FPT CONDENSER WATER OUT NSF/ UL APPROVED Q -450 CUBER ON S -400 BIN TYPE: AIR - COOLED, WATER - COOLED, REMOTE. ELECTRICAL SPECIFICATIONS 115/60/1 20 AMP FUSE MIN. AIR - COOLED = 12.8 AMPS, WATER - COOLED = 11.9 AMPS REMOTE = 9.6 AMPS WIRED DIRECT OR PER LOCAL CODE 220 - 240/50/1 ALSO AVAILABLE, SEE MANUFACTURER. PLUMBING SPECIFICATIONS 3/8" (0.95cm) F.P.T. INLET, 1/2" (1.27cm) F.P.T. DRAIN 3/4" (1.91cm) BIN DRAIN 3/8" (0.95cm) F.P.T. WATER CONDENSER INLET (WATER - COOLED UNIT) 1/2" (1.27cm) F.P.T. WATER CONDENSER OUTLET (WATER - COOLED UNIT) NSF APPROVED /U.L. #SA- 4027 /CSA LISTED MANITOWOC ICE CUBER REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 9 2009 City of Tukwila BUILDING DIVISION *100, 200, 300 AND 400 ARE STANDARD SUBWAY MODEL SIZES. ENGINEERING SPECIFICATIONS: ACID RESISTANT COATED INTERIOR AND EXTERIOR FABRICATED STEEL. INTERNAL AIR RELIEF BYPASS. BRONZE CLEANOUT PLUG. REMOVABLE PRESSURE EQUALIZING /FLOW DIFFUSING INLET BAFFLE. FIXED BOTTOM OUTLET BAFFLE. VISIBLE DOUBLE WALL TRAP SEAL. RECEIVED MAY 22 7fl(l4 PERMIT CENTER NOTE: THESE DRAWINGS REPRESENT TYPICAL EQUIPMENT PURCHASED THROUGH DOCTOR'S ASSOCIATES INC. AND DOES NOT OWNERS OF STORES OUTSIDE THE ENT PURCHASED LOCALLY BY THE FRANCHISEE/OWNER. EPRESENT ANY E U/PM R Q UNITED STATES AND CANADA MAY NEED ALTERNATE ELECTRICAL REQUIREMENTS. CONTACT YOUR DAI COORDINATOR OR THE MANUFACTURER FOR THE MODIFIED ELECTRICAL SPECIFICATIONS. STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ('DAI ") D /B /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND /OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAI'S AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAPS STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. REVISION: w a SHEET #: 30f4 02008 DOCTORS ASSOCIATES, INC. SUBWAY* WORLD HEADQUARTERS 325 BIC DRIVE (203) 877-4281 MILFORD, CT 06461 (800) 888-4848