HomeMy WebLinkAboutPermit M09-066 - ARCO AM/PMARCO AM /PM
5800 SOUTHCENTER BL
M09 -066
Parcel No.:
Address:
Suite No:
doc: IMC -10/06
City(If Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
1157200352
5800 SOUTHCENTER BL TUKW
Tenant:
Name: ARCO AM /PM NO 83098
Address: 5800 SOUTHCENTER BL , TUKWILA WA
Owner:
Name: YAMASHITA SUSIE
Address: YOSHINO INC , 5800 SOUTHCENTER BLVD
Contact Person:
Name: ALEXIA INIGUES
Address: 18215 72 AV S , KENT WA
Contractor:
Name: JOE PARK CONSTRUCTION LLC
Address: PO BOX 527 , YAKIMA WA
Contractor License No: JOEPACL994DE
DESCRIPTION OF WORK:
INSTALL TYPE II EXHAUST HOOD OVER CONVECTION WITH THRU -ROOF EXHAUST FAN.
RELOCATE EXHAUST FAN AND INSTALL (2) NEW. RELOCATE AIR SUPPLY /RETURN AIR GRILL
TO ACCOMMODATE NEW HOOD LOCATION. PROVIDE NEW DIFFUSER IN NEW RESTROOM.
Value of Mechanical: $5,500.00
Type of Fire Protection: NONE
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat /Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
MECHANICAL PERMIT
Fees Collected: $242.81
International Mechanical Code Edition: 2006
EQUIPMENT TYPE AND QUANTITY
0
0
0
0
0
0
0
0
0
2
0
1
0
0
* *continued on next page **
M09 -066
a
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 425 251 -6222
Phone: (509)452 -5122
Expiration Date: 03/05/2011
M09 -066
11/02/2009
05/01/2010
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 - 15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 1
Thermostat 0
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment
Printed: 11 -02 -2009
Permit Center Authorized Signature:
I hereby certify that I have read an ex ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be compli wit , whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the perform ce of work. I am authorized to sign and obtain this mechanical permit. �/ �7 n
Signature: Date:��u Cam
Print Name:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
Permit Number: MO9 -066
Issue Date: 11/02/2009
Permit Expires On: 05/01/2010
Date: 11 1 021
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -10/06
M09 -066 Printed: 11 -02 -2009
Parcel No.: 1157200352
Address:
Suite No:
Tenant:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
5800 SOUTHCENTER BL TUHW
ARCO AM /PM NO 83098
1: ** *BUILDING DEPARTMENT CONDITIONS * **
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
M09 -066
ISSUED
06/08/2009
11/02/2009
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: Cond -10/06
* *continued on next page **
M09 -066 Printed: 11 -02 -2009
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name:
doc: Cond -10!06
Date•
M09 -066 Printed: 11 -02 -2009
SITE LOCATION
Tenant Name:
CITY OF TUKWIL•
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.ci.tukwila.wa.us
Site Address: 5800 Southcenter Boulevard, Tukwila, WA 98188 Suite Number:
ARCO AM /PM Facility No. 83098
Property Owners Name: BP West Coast Products LLC
Mailing Address: 4 Centerpointe Drive
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Name: Alexia Inigues, Barghausen Consulting Engineers, Inc.
Mailing Address: 18215 = 72nd Avenue South
E -Mail Address: ainigues @barghausen.com
Company Name: Barghausen Consulting Engineers, Inc.
Mailing Address: 18215 - 72nd Avenue South
Contact Person:_ - Caryl Mattson
E -Mail Address: cmattson @barghausen.com
Company Name: Barghausen Consulting Engineers, Inc.
Applications and plans must be complete in order to be accepted for plan review.
Applications Will not be accepted through the mail or by fax.
* *Please Print **
Mailing Address: 18215 - 72nd Avenue South
Contact Person: Caryl Mattson
E -Mail Address: cmattson @barghausen.com
H:\Applications\Forms- Applications On Line\2009 Applications \I-2009 - Mechanical Permit Applicaiion.doc
Revised: 1 -2009
bh
MECHANICAL PERMIT APPLICATION
Mechanical Permit No.
Project No.
(For office use only)
01--
King Co Assessor's Tax No.: 115720 -0352
La Palma
City
Day Telephone: (425) 261 -6222
Kent WA
City
State
Fax Number: (425) 251 -8782
MECHANICAL CONTRACTOR INFORMATION
Company Name.
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
v
J
City
Day Telephone:
Fax Number:
Expiration Date:
State
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Kent WA
City State Zip
Day Telephone: (425) 251 -6222
Fax Number: (425) 251 -8782
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Kent
City
Day Telephone:
Fax Number:
New Tenant:
CA
Floor:
Yes VI -No
State
90623
Zip
98032
Zip
98032
WA 98032
State Zip
(425) 251 -6222
(425) 251 =8782
Page I of2
1975.031.pdf.doc
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
0 -3 HP /100,000 BTU
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
Furnace >100K BTU
Evaporator Cooler
Diffuser
1
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct _
2
Thermostat
15 -30 HP /1,000,000
BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000
BTU
Appliance Vent
Hood and Duct
1
Emergency Generator
50+ HP /1,750,000 BTU
Repair or addition to
Heat/Refrig/Cooling System
Incinerator — Domestic
Other Mechanical
Equipment
Air Handling Unit <10,000
CFM
Incinerator — Comm/Ind
Valuation of Project (contractor's bid price): $ 5,500
Scope of Work (please provide detailed information): install type II exhaust hood_over convection over with thru -roof
exhaust fan. relocate exhaust fan and install 2 new. relocate air supply /return air grill to accommodate new hood
location. provide new diffuser in new rest room.
Fuel Type: Electric
•
Use: Residential: New U Replacement
Commercial: New ❑ Replacement
Indicate type of mechanical work being installed and the quantity below:
Gas ❑ Other:
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
cr/o7
Print Name: 4fr)(la J V / oP$ Day Telephone: 1 /Z9 9 ' 2 5 lr/ 2 - 22 -
. � Kd
Mailing Address: ga 17 °� ie/7 / 16&'] -7 city WA state Zip
Signature:
Date Application Accepted:
❑
Date:
Date Application Expires:
01 k
H:\Applications\Forms- Applications On Line\2009 Applications \I -2009 - Mechanical Permit Application.doc
Revised: 1 -2009
bh
Staff Initials:
i
gc 2 of 2
1975.031.pdf.doc
Parcel No.: 1157200352 Permit Number: M09 -066
Address: 5800 SOUTHCENTER BL TUKW Status: APPROVED
Suite No: Applied Date: 06/08/2009
Applicant: ARCO AM /PM NO 83098 Issue Date:
Receipt No.: R09 -01719
Initials:
User ID:
Payee:
JEM
1165
ACCOUNT ITEM LIST:
Description
JOE PARK CONSTRUCTION LLC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 6077 242.81
Authorization No.
MECHANICAL - NONRES
PLAN CHECK - NONRES
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
•
Payment Amount: $242.81
Account Code Current Pmts
000.322.102.00.00 194.25
000.345.830 48.56
Total: $242.81
Payment Date: 11/02/2009 01:30 PM
Balance: $0.00
PAYMENT
RECEIVED
doc: Receipt -06 Printed: 11 -02 -2009
Proj t: •
/ WOP An'1 /491
Type of Inspection:
/i/ A/4
Address:
Date Called:
Special Instructions:
Date Wanted? /
// , 55.
P.m.
Requester:
Phone No:
Receipt No.:
r�
i
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO:
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 V
Approved per applicable codes. Corrections required prior to approval. /
COMMENTS:
p Aii . .`r 6A LA
Insp ctor:
A
Date:
i II
❑ $60.00 REINSPECTION FEE REQUIRED. Pri r to inspection, fee must be
paid at 6300.Southcenter�Blvd., Suite 100. Call to schedule reinspection.
Date:
COMMENTS:
Type of spection:
A ii &H -� 41
11) A eee9, yPXin A -, ) t
f- (---
1 1
Special Instructions:
79 )<Lv' (A5r — ca
1 A4
Requester:
Phone No:
7 2) N A.t
s p e -c .(
,) 4
7>.1£ A-,-r- .-
ja S G,
—
AR
r ,)L- �-,,. , c ez,r
A
ke21 r
'I.,
( L),..ip i a s[ .
•
Project:
4 /1 (Po A n1 /pin
Type of spection:
A ii &H -� 41
Address:
8800
l ,'6 —
Date Called:
Special Instructions:
Date Wanted:
/y / / / /,
P.m.
Requester:
Phone No:
*-1
INSPECTION RECORD
Retain a copy with permit 1
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
0 Approved per applicable codes.
Inspector:
d
Corrections required prior to approval.
Date:
$60.00 REINSPECTION FEE - REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
11 -02 -2009
ALEXIA INIGUES
18215 72 AV S
KENT WA 98032
RE: Permit Application No. M09 -066
5800 SOUTHCENTER BL TUKW
Dear Permit Applicant:
In reviewing our current application files, it appears that your permit applied for on 06/08/2009, has not been
issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code,
Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days
from the date of application shall expire and become null and void. Your permit application will expire on
12/05/2009.
If you still plan to pursue your project, a written request for extension of your application must be submitted to the
Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building
Official and state your reason(s) for the need to extend your permit application. If it is determined that an
extension is granted, your application will be extended for an addtional 90 days from the expiration date and you
will be notified by mail.
In the event that we do not receive your written request for extension or request was denied, your permit
application will expire, become null and void and your project will require a new permit application, plans and
specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File: Permit File No. M09 -066
0
City of Tukwila
Department of Community Development
'<„i.P 'Z,,,...ii,
•
Jim Haggerton, Mayor
Jack Pace, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
Bill Rambo, Permit Technician
City of Tukwila Community Development
6300 Southcenter Boulevard, STE #100
Tukwila, WA 98188
• •
July 8, 2009
CIVIL ENGINEERING, LAND PLANNING, SURVEYING
RE: Response to Comments Permits #PG09 -057 / #M09 -066 / #D09 -096 / PW Comments
ARCO AM /PM Interior Retrofit
5800 Southcenter Boulevard, Tukwila, Washington
ARCO FAC No. 83098 (6155) / Our Job No. 1975.75
Dear Bill:
We have revised the plans and technical documents for the above - referenced permits and in accordance
with the comment letters listed below. Although no revisions were required for the Electrical plans (E1.1-
E1.4), we are submitting two (2) complete revised sets of those as well due to other department reviews.
Accordingly, enclosed are the following documents for your review and approval:
1. Plumbing Review: 1'
a) Two (2) REVISED Plumbing Drawings sheet P1.1
b) One (1) City of Tukwila Revisions Submittal Cover Sheet for PG09 -057
c) One (1) copy of Plumbing Permit Correction Letter #1, dated June 18, 2009
2. Mechanical Review: J/ O '1 —01,4
a) Two (2) REVISED Mechanical Drawings sheet M1.1
b) One (1) City of Tukwila Revisions Submittal Cover Sheet for M09 -066
c) One (I) copy of Mechanical Permit Correction Letter #1, dated June 15, 2009
3. Development / Building Review: mot --D't
a) Four (4) complete REVISED Building Plan Sets
b) One (1) City of Tukwila Revisions Submittal Cover Sheet for D09 -096
c) One (1) copy of Development Permit/ Building Correction Letter #1, dated June 22,
2009
4. Public Works Review: iv 0 `� 5
a) Four (4) Plan Sheets for Installation of Reduced Pressure Principle Assembly (RPPA)
sheet AU 1.1.
18215 72ND AVENUE SOUTH KENT, WA 98032 (425) 251 -6222 (425) 251 -8782 FAX
BRANCH OFFICES • OLYMPIA, WA 0 TACOMA, WA • CONCORD, CA 0 TEMECULA, CA
www.barahausen.com
• •
Bill Rambo, Permit Technician July 8, 2009
City of Tukwila Community Development -2-
b) One (1) Type C Permit Fee Construction Cost Estimate for Backflow Installation,
prepared by a licensed Engineer (sealed)
c) One (1) copy of Public Works Request for compliance with cross - connection control
program
The following outline provides each of your comments in italics exactly as written, along with a narrative
response describing how each comment was addressed:
Plumbing Comments: June 12, 2009 by Allen Johannesson, Plans Examiner (206) 433 - 7163
1. The door opening into the bathroom in front of the sink does not meet accessibility for
60 inch minimum maneuvering clearances at doors. Also doors shall not swing into the clear
flood space of any fixture. Please revise the floor plan for the bathroom where the door and
fixtures shall be placed to meet accessibility clear floor space and maneuvering
requirements. (ANSI 404.2.3 & 1004.11.1.1)
Response: Interior door to restroom has been reduced to 34" wide, lavatory has been rotated
and new exterior wall was pushed out a few inches to accommodate the required space, see
sheet A1.1.
Mechanical Comments: June 10, 2009 by Allen Johannesson, Plans Examiner (206) 433 - 7163
1. Makeup air shall be required for the new Type II duct. Makeup air shall be supplied during
the operation of commercial kitchen exhaust systems that are provided for commercial
cooking appliances. The amount of makeup air supplied shall be approximately equal to the
amount of exhaust air. The mechanical makeup air and exhaust system shall be electrically
interlocked to ensure that makeup air is provided whenever the exhaust system is in
operation. The amount of makeup air shall be approximately equal to the amount of exhaust
air and not reduce the effectiveness of the exhaust air. The temperature differential between
makeup air and the air in the conditioned space shall not exceed 10 degrees. Identify
provisions on the plan with relative documentation for a makeup air system that is
electronically interlocked with the new Type II hood (IMC 508.1 & 508.1.1)
Response: The existing mechanical units are providing outside air. The outside air will be used
as make -up air for the "Type II" exhaust hood fan. (Please refer to general notes and air balance
schedule on plan sheet M1.1.) The fan operation of "Type II" exhaust hood fan shall be
interlocked with the existing HVAC units, as indicated in the general notes section of the revised
drawing M1.1 .
Building Comments: June 12, 2009 by Joanna Spencer, Development Engineer (206) 431 - 2440
1. The door opening into the bathroom in front of the sink does not meet accessibility for
60 inch minimum maneuvering clearances at doors. Also doors shall not swing into the clear
floor space of any fixture. Please revise the floor plan for the bathroom where the door and
• •
Bill Rambo, Permit Technician July 8, 2009
City of Tukwila Community Development -3-
fixtures shall be placed to meet accessibility clear floor space and maneuvering
requirements. (ANSI 404.2.3 & 1004.11.1.1)
Response: Interior door to restroom has been reduced to 34" wide, lavatory has been rotated
and new exterior wall was pushed out a few inches to accommodate the required space, see
sheet A1.1.
2. Sheet A1.1A details 02 & 03 indicated R -30 ceiling insulation and the detail (03) shows R -19
for a wall infill. Revise plan to show R -38 attic insulation and all new exterior walls R -21.
(2006 WSEC Table 13 -1 & footnote #3)
Response: R38 ceiling insulation has been noted and R21 is noted for the exterior walls on
sheet AI.1A.
Public Works Comments: June 19, 2009 by Joanna Spencer, Development Engineer (206) 431-
2440
A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow
Assembly (RPBA) shall be installed immediately downstream of the existing permanent water
meter. Installation at another location requires the Public Works Director's approval. The
RPPA shall be installed in a Hot Rock/Box or equal freeze protection enclosure anchored to a
minimum 4" concrete pad. Public Works strongly recommends a power supply for the freeze
protection enclosure. On your site plan please show the property line(s), street name, North
arrow, building location and size of existing permanent water meter and proposed RPPA. Show
manufacturer name and backflow model number. Submit RPPA cut sheet and a construction cost
estimate for backflow installation.
Response: A RPPA has been added to the project reference sheet AU1.1 for more information.
We believe that the above responses, together with the enclosed revised plans and technical documents,
address all of the comments in The City of Tukwila C \correction letters listed above. Please review and
approve the enclosed at your earliest convenience. If you have questions or need additional information,
please do not hesitate to contact me at this office at 425- 656 -7430 or ainigues @barghausen.com. Thank
you.
Sincerely,
MAI /LKH/pj [1975c.061.doc]
enc: As Noted
cc: Brian Wall, Global Alliance Bovis Lend Lease
Jay S. Grubb, Barghausen Consulting Engineers, Inc.
Daniel B. Goalwin, Barghausen Consulting Engineers, Inc.
Caryl Mattson, Barghausen Consulting Engineers, Inc.
% 1&
4 $44. Alexia Inigues
Project Planner
June 15, 2009
Alexia Inigues
18215 72 Ave S
Kent, WA 98032
RE: CORRECTION LETTER #1
Mechanical Permit Application Number M09 -066
ARCO AM/PM — 5800 Southcenter Bl
Dear Ms. Inigues,
City of f 7'il tia
S
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your mechanical permit(s) can be
approved. All correction requests from each department must be addressed at the same time and
reflected on your drawings. I have enclosed comments from the Building Department. At this time the
Fire Department has no comments.
Building Department: Allen Johannessen at 206 433 -7163 if you have question s regarding
the attached memo.
Please address the attached comments in an itemized format with applicable revised plans,
specifications, and /or other documentation. The City requires that two (2) complete sets of revised
plans, specifications and /or other documentation be resubmitted with the appropriate revision
block.
In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person
and will not be accepted through the mail or by a messenger service.
If you have any questions, please contact me at (206) 431 -3670.
Sincerely,
eqAAStf
Bill Rambo
Permit Technician
encl
File: M09 -066
W:\Perrnit Center\Correction Letters \2009\M09 -066 Correction Letter #1.DOC
wer
/r ?nn Cnnthrontor Rnrrlou,rrl Cnito kiln/) • Tiilruiih Lihchinntnn OR1RR m Ahnnn• 9/)A_A 21.2A7/1 n J ,... 9nA_A21_2!.AC
Building Division Review Memo
Date: June 10, 2009
Project Name: ARCO AM/PM
Permit #: M09 -066
Plan Review: Allen Johannessen, Plans Examiner
Tukwila Building Division
Allen Johannessen, Plan Examiner'
The Building Division conducted a plan review on the subject permit application. Please address the
following comments in an itemized format with revised plans, specifications and/or other applicable
documentation.
(GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 1 lx17 to maximum size of 24x36; all sheets shall be the same size).
(If applicable) Structural Drawings and structural calculations sheets shall be original signed wet
stamped, not copied.)
1. Makeup air shall be required for the new Type II duct. Makeup air shall be supplied during the
operation of commercial kitchen exhaust systems that are provided for commercial cooking
appliances. The amount of makeup air supplied shall be approximately equal to the amount of
exhaust air. The mechanical makeup air and exhaust system shall be electrically interlocked to ensure
that makeup air is provided whenever the exhaust system is in operation. The amount of makeup air
shall be approximately equal to the amount of exhaust air and not reduce the effectiveness of the
exhaust air. The temperature differential between makeup air and the air in the conditioned space
shall not exceed 10 degrees. Identify provisions on the plan with relative documentation for a
makeup air system that is electronically interlocked with the new Type II hood. (IMC 508.1 &
508.1.1)
Should there be questions concerning the above requirements, contact the Building Division at 206 -431-
3670. No further comments at this time.
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: M09 -066 DATE: 07 -08 -09
PROJECT NAME: ARCO AM /PM
SITE ADDRESS: 5800 SOUTHCENTER BL
Original Plan Submittal Response to Incomplete Letter #
X Response to Correction Letter # 1
Revision # After Permit Issued
DEPARTMENTS:
�JG Dl- 1 g
Building Division
Public Works
Fire Prevention
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28 -02
*PERMIT COORD COPY �
Incomplete n
TUES/THURS ROUTING:
Please Route Structural Review Required U
REVIEWER'S INITIALS:
Planning Division
Structural ❑ Permit Coordinator ❑
DUE DATE: 07-09-09
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
No further Review Required ❑
DATE:
DATE:
DUE DATE: 08-06-09
Not Approved (attach comments) C
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
ACTIVITY NUMBER: M09 -066 DATE: 06 -09 -09
PROJECT NAME: ARCO AM /PM
SITE ADDRESS: 5800 SOUTHCENTER BL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPART A e Sr 1)
'Building Mision
Public Works
Complete Er
Comments:
TUES /THURS ROUTING:
Please Route
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Documents/routing slip.doc
2 -28 -02
•PERMFr COORD COPY
PLAN REVIEW/ROUTING SLIP
A� NSA t
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete
Structural Review Required
DUE DATE: 06-11-09
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
No further Review Required n
DATE:
DUE DATE: 07-09-09
Approved n Approved with Conditions n Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
DATE:
Planning Division
Permit Coordinator
Not Applicable
n
u
Permit Center Use Only
CORRECTION LETTER MAILED: t 'S - 0q
Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 1/
Date: I ' am ct
Project Name: ARCO AM /PM
Project Address: 5800 Southcenter Boulevard
Contact Person: M
Summary of Revision:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: //www.ci.tukwila.wa.us
Plan Check /Permit Number: M09 -066
❑ Response to Incomplete Letter #
Q Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Alexia Inigues
Please see response to comments letter attached dated July 8, 2009.
BCE #1975.75
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
try or rt
0 8 2009
istAimir CENT
425 -656 -93. 944 END
Phone Number: al ni gues9tharghausen. com
Sheet Number(s): Sheet No. M1.1
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by: I J�
Entered in Permits Plus on f10 �
\applications \forms - applications on line \revision submittal
Created: 8 -13 -2004
Revised: 1 -2009
1975.036.pdf
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
2
TRAVELERS
CAS it
SURETY CO
103408839
03/05/2002
Until
Cancelled
4/1 /2001
ARCHIVED
$12,000.00
02/14/2002
1
TRAVELERS
CAS ft
SURETY CO
103408839
03/05/2001
03/05/2002
$6,000.00
03/05/2001
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
JWPARCL033JA
J W PARK
CONSTRUCTION
LLC
CONSTRUCTION
CONTRACTOR
GENERAL
UNUSED
4/1/1997
4/1 /2001
ARCHIVED
Untitled Page
General /Specialty Contractor
A business registered as a construction contractor with Lai to perform construction work
within the scope of its specialty. A General or Specialty construction Contractor must
maintain a surety bond or assignment of account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent
Company
JOE PARK CONSTRUCTION
LLC
5094525122
PO BOX 527
YAKIMA
WA
989070527
YAKIMA
Limited Liability Company
UBI No.
Status
License No.
License Type
Effective Date
Expiration
Date
Suspend Date
Specialty 1
Specialty 2
602100482
ACTIVE
JOEPACL994DE
CONSTRUCTION
CONTRACTOR
3/5/2001
3/5/2011
GENERAL
UNUSED
Other Associated Licenses
1
Business Owner Information
Name
PARK, JOE
Role
Effective Date
01/01/1980
Expiration Date
Bond Information
Insurance Information
I
I
S
I
I
I
I
•
I
Page 1 of 2
I
https: // fortress .wa.gov /lni/bbip/Detail.aspx 11/02/2009
ARCO
BP WEST COAST PRODUCTS, LLC
V'
k G
S64'26'45 "E 104.85' ____
mat \ . \ t \ vk \ \ \0sx \\ O \ \ \\ t►O \ .. \ \ a xt o x► . u \ \ \ q1 \ \ u IT\ NNIo s IN0IN V NOM Vii _ XX \ N Vi
._
11 1
EXISTING PARKING
EXISTING DRIVEWAY
±58' -0" TO NEW ADDITION
NEW EXHAUST
FAN
EXISTING PARKING
EXISTING
OFFICE
EXISTING
SALES
ROOM
EXISTING PARKING
EXISTING PLANTER
[ :� NEW
l � UNISEX
e \ RESTROOM
HOT FOOD
PROGRAM
EXPAND SALES AREA INTO
EXISTING COVERED PORCH
AREA
- EXISTING PIC
UNIT, COLUMN
MTD.
EXISTING PIC
UNIT, COLUMN
MTD.
REMODEL INTERIOR OF
EXISTING CONVENIENCE
STORE
REPAINT EXTERIOR
REPLACE SIGN
A =1' 36' 16"
EXISTING
SALES
ROOM
EXISTING CANOPY
TO REMAIN.
PROVIDE NEW
GRAPHICS
• EXISTING ADA
RAMP
R= 5658:65' L= 158.49'
SOUTHCENTER BOULEVARD
— 26SF ADDITION TO
ACCOMMODATE NEW UNISEX
ACCESSIBLE RESTROOM
EXISTING
COOLER
RESTRIPE /PAINT EXISTING
ACCESSIBLE PARKING STALL
(AND PATH) REFER TO AS1.2
EXISTING UNDERGROUND
STORAGE TANKS
EXISTING DRIVEWAY
REPAINT DIRECTIONAL
ARROWS, TYPICAL
154TH
144TH ST.
STRANDER BLVD.
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new p!arl submittal
and may include additional plan review fees.
SITE DATA
ADDRESS: 5800 SOUTHCENTER BLVD.
TUKWILA, WASHINGTON
OWNER: BP WEST COAST PRODUCTS, LLC
4 CENTERPOINTE
LA PALMA, CA
LO'r SIZE: 18,593 SQUARE FEET
APN: 1157200352
ZONING: RCM (REGIONAL COMMERCIAL MIXED -USE)
BUILDING AREA: 1,811.4 SQUARE FEET (EXISTING)
26 SQUARE FEET ADDITION TO STORE
1,500 SF (CANOPY)
CC{NSTRUCTION TYPE: II -B NON - SPRINKLERED (STORE); H -B (CANOPY)
OCCUPANCY: M (STORE AND GAS)
HEIGHT: EXISTING ±18'
TENANT IMPROVEMENT TO EXISTING STORE INTERIOR CONSISTING, BUT
NOT "LIMITED TO:
• DEMOLITION AND REPLACEMENT OF NON LOAD BEARING WALLS
:NEW FLOOR FINISHES
.LIGHTING IMPROVEMENTS
NEW CABINETS & COUNTERTOPS
NEW FOOD SERVICE EQUIPMENT
NEW GONDOLAS
NEW WALL FINISHES AND PAINTING
UPDATE EXTERIOR SIGNS
.UPDATE EXTERIOR PAINT COLORS
2006 INTERNATIONAL BUILDING CODE
2006 INTERNATIONAL FIRE CODE
2006 UNIFORM PLUMBING CODE
2006 NATIONAL ELECTRICAL CODE
2006 INTERNATIONAL MECHANICAL CODE
DWG NO.
AS1.1 SITE PLAN
ARCHITECTURAL
A.1.1 CONSTRUCTION FLOOR PLAN
A.1.2 FLOOR FINISH PLAN
A.1.3 REFLECTED CEILING PLAN
A.2.0 EXTERIOR ELEVATIONS C -STORE & CANOPY
A.2.3 INTERIOR ELEVATIONS
A.2.4 - INTERIOR ELEVATIONS
A 25 INTERIOR ELEVATIONS
EQUIPMENT
Q1.1 EQUIPMENT PLAN
Q2.1 EQUIPMENT SCHEDULE
ELECTRICAL
E1.1 ELECTRICAL ROUGH -IN PLAN
ELECTRICAL FLOOR PLAN
ELECTRICAL DEMO /LIGHTING PLAN
ELECTIRCAL SCHEDULES & DIAGRAMS
E1.2
E1.3
E1.4
{
PLUMBING
P.1.1 PLUMBING DEMOLITION /ROUGH -IN PLANS, NOTES, LEGENDS
MECHANICAL
M.1.1 MECHANICAL PLAF
REIMAGE
KNIFES & DETAILS
0 --RAP
& DETAILS
Plan review approval Is subject to errors and om authorize Approval of construction documents does not authorize
the violation of any adopted code or ordinance Receipt
of approved Field Copy and conditions is acknowledged` ��. �F gyp,
By �� IA o 9 2009
Date: A / Q Q PERMIT CENTER
City Of 1Ukwiia
BUILDING D VAS gi
CLIENT:
SHEET NO:
2 ` � F�.�r � NV �r
ENG
18215 72ND AVENUE SOUTH
KENT, WA 98032
(425)251 -6222
(425)251 -8782 FAX
CIVIL ENGINEERING, LAND PLANNING,
SURVEYING, ENVIRONMENTAL SERVICES
NO. DATE REVISION DESCRIPTION
T 05.26.09 PERMIT REVIEW - BP
\ 06.05.09 ISSUED FOR PERMIT - CITY
/s\
A
L
A A t2
SEAL:
S G,
JP 0 W A Sy ,.:.•�
1.„.., p,
28527
.
W E i"1
� b I
CONFIDENTIALITY STATEMENT:
`
THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT
COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL
ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN
PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF
GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO
RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND
AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER
PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE
MATERIALS. THE RECIPIENT AGREES TO USE THE
MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH
GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE,
AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO
GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE
INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL
ALLIANCE, WHICHEVER COMES FIRST.
DEVELOPMENT INFORMATION:
2009 RETROFIT
BACKCOURT
L&M - FULLERTON
SITE ADDRESS:
5800 SOUTHCENTER BLVD.
@ 1.5
TUKWILA, WASHINGTON
FAC 83098
DESIGNED BY: ALLIANCE Z&DM:
CHECKED BY: BP REPM:
DRAWN BY: ALLIANCE PM
VERSION: PROJECT N0:
1975.75
DRAWING TITLE:
SITE PLAN
GENERAL PROJECT NOTES
A. ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE BUILDING CODES AND LOCAL RESTRICTIONS.
CONTRACTORS MUST COMPLY WITH CONTRACTOR REGISTRATION REQUIREMENTS OF ALL GOVERNING
AUTHORITIES. THE GENERAL BUILDING PERMITS SHALL BE PAID FOR BY THE OWNER. ALL OTHER PERMITS
SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR DIRECTLY RESPONSIBLE. ALL REQUIRED CITY,
COUNTY AND/OR STATE LICENSES SHALL BE ACQUIRED AND PAID FOR BY THE INDIVIDUAL SUBCONTRACTOR.
B. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY WORKMEN. ALL
CONSTRUCTION SETS SHALL REFLECT SAME INFORMATION. CONTRACTOR SHALL MAINTAIN ONE COMPLETE SET
OF PLANS ON THE PREMISES IN GOOD CONDITION AT ALL TIMES. THIS SHALL INCLUDE ALL ADDENDA AND
CHANGE ORDERS.
C. DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS, DRAWINGS AND SPECIFICATIONS ARE NOT
INTENDED. THE CONTRACTOR IS TO CLARIFY ANY SUCH DISCREPANCIES WITH THE ARCHITECT /CONSULTANT
PRIOR TO COMMENCING WORK.
D. STATED DIMENSIONS TAKE PRECEDENCE OVER GRAPHICS, DO NOT SCALE DRAWINGS TO DETERMINE
LOCATIONS. THE ARCHITECT /CONSULTANT SHALL BE NOTIFIED OF ANY SUCH DISCREPANCIES PRIOR
TO CONTINUING WITH WORK.
E. GENERAL CONTRACTOR TO REFER TO THESE DOCUMENTS AS WELL AS SPECIFICATIONS FOR IDENTIFICATION OF
ALL OWNER SUPPLIED ITEMS, ALL ITEMS NOT MARKED AS 'OWNER SUPPLIED' ARE TO BE SUPPLIED BY
GENERAL CONTRACTOR. UNLESS NOTED OTHERWISE, ALL ITEMS ARE TO BE INSTALLED BY GENERAL
CONTRACTOR.
F. FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S APPROVED SHOP DRAWINGS /DATA
SHEETS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
G. THE . CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE JOB IS IN
PROGRESS AND UNTIL BUILDING IS OCCUPIED.
H. ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN (BROOM)
CONDITION AT ALL TIMES.
I. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND
WORKERS ! AT ALL TIMES.
J. CONTRACTOR SHALL PROVIDE TEMPORARY WATER, POWER AND TOILET FACILITIES AS REQUIRED.
K. GENERAL CONTRACTOR IS RESPONSIBLE FOR RECEIVING, UNLOADING, UN— CRATING, INSTALLATION AND HOOKUP
OF ALL FOOD SERVICE EQUIPMENT AND OTHER OWNER FURNISHED ITEMS.
L. GENERAL CONTRACTOR IS REQUIRED TO LABEL ALL ELECTRICAL PANELS, PLUMBING. VALVES, AND ROOF TOP
EQUIPMENT. PLASTIC . PHENOLIC ENGRAVED PLATE SCREWED ON.
M. IT IS THE INTENT OF THE ARCHITECT THAT THIS WORK BE IN CONFORMANCE WITH ALL REQUIREMENTS OF
THE BUILDING AUTHORITIES HAVING JURISDICTION OVER THIS TYPE OF CONSTRUCTION AND OCCUPANCY.
N. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE
CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT
DETAIL IS SHOWN.
0. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION. PROCEDURE AND SEQUENCE TO
INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION.
P. MATERIALS LISTED IN DRAWINGS ARE BASED ON DESIGN INTENT. ALTERNATE SPECIFICATIONS MAY BE
ACCEPTED PROVIDED THEY CLOSELY MATCH SPECIFIED MATERIAL. CONTRACTOR IS TO SUBMIT PROPOSED
SAMPLES OF SUBSTITUTIONS, ALONG WITH SAMPLE OF THAT SPECIFIED IN DRAWINGS FOR REVIEW BY
THE OWNER.
Q. GC TO REFER TO BID DOCUMENT PACKET FOR OWNER'S SCOPE OF WORK. SAID DOCUMENT TAKES
PRECEDENCE OVER ANY SCOPE THAT MAY BE PRESENTED IN THIS SET OF CONSTRUCTION DOCUMENTS OR
SPECIFICATIONS.
SITE PLAN
R. ALL WORK SHALL BE PERFORMED AS SHOWN ON THESE PLANS AND IN
ACCORDANCE WITH "ARCQ'" STANDARD SPECIFICATIONS.
S. WHERE LOCAL CODES, ORDINANCES OR REGULATIONS ARE MORE RESTRICTIVE
THAN "ARCO'S" STANDARD SPECIFICATIONS, THEIR LOCAL REQUIREMENTS
SHALL GOVERN.
T. ANY DISCREPANCY BETWEEN FIELD CONDITIONS AND THESE PLANS ARE TO BE
IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER. NO WORK SHALL
BE PERFORMED ON THE ITEMS IN QUESTION UNTIL DIRECTED BY THE OWNER.
NOTE: BARGHAUSEN HAS NOT PERFORMED AN ADA SURVEY TO VERIFY THE
EXISTING SITE AND STORE ACCESSIBILITY. CONTRACTOR TO CONFIRM LOCAL
ACCESSIBILITY WITH INSPECTOR AS REQUIRED. CONTACT GLOBAL ALLIANCE PM
OR FRANCHISE CONSULTANT TO GET COPY OF LAST SURVEY AND TO CONFIRM
ALL NECESSARY UPGRADES FOR CONSENT DECREE HAVE BEEN PERFORM EPARATE PERMIT
REQUIRED FOR:
❑ Mechanical
14 Electrical
Plumbing
as Piping
SCALE:
1"= 20'
City of Tukwila
BUILDING DIVISION
CONSUL TA/VTS
ARCHITECT /ENGINEER:
CONTACTS:
PLUMBING /MECHANICAL /ELECTRICAL:
CONTACT:
Irt
BARGHAUSEN CONSULTING ENGINEERS INC.
18205 72ND AVENUE S.
KENT, WA 98032
DANIEL B. GOALWIN (425) 656 -7441
CARYL J. MATTSON (425) 656 -1063
SACRAMENTO ENGINEERING CONSULTANTS
10555 OLD PLACERVILLE ROAD
SACRAMENTO, CA 95827
CHRIS GILLAND, (916) 368 -4468
c ONF/DEN T /AL /T Y STATEMEIVT:
THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE
MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS
CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL
ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN
STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY
OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS.
THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE
FOR WHICH GLOBAL ALLIANCE HAS MADE THE THE MATERIALS AVAILABLE, AND
RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER
UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF
GLOBAL ALLIANCE, WHICHEVER COMES FIRST.
DUCTWORK BETWEEN EXHAUST RISER
ON HOOD AND FAN (BY OTHERS)
EXHAUST FAN DETAIL
SCALE: 1/4"=1'-0"
CURB ASSEMBLIES
NO FAN ITEM SIZE
1 # 1 Curb 19.500 "W x 19.500 "L x 22.000 "H Vented
UPBLAST EXHAUST FAN
MODEL #DU33HFA (95 LBS EACH)
BACKROOM
II H1 11 II II
EXISTING COVERED
TRASH ENCLOSURE
MIECHANICAL PLAN
ampm COFFEE
25 1/2" DIA
12 1/8"
DIA
21" SQ.
t�lf�I 11F-1
1 H ILJ� 1
EXISTING
STORAGE
1
THE TRANSITION BETWEEN
THE DUCTWORK AND FAN
BASE SHOULD BE EQUAL
TO OR GREATER THAN R
(DIA) DIMENSION ///i
ROOF OPENING
DIMENSIONS 18" X
18" 18 18" 18','
amca
CERTIFIED
RATINGS /.
A I R
SO AND
VENTED CURB
ETL LISTED PER UL 705
20 GAUGE ALUMINIZED
STEEL CONSTRUCTION
3" CONTINUOUS
FLASHING
NEW UNISEX
REST ROOM
EXISTING STORAGE
CONTAINER
DUL /HFA DIRECT DRIVE
CENTRIFUGAL UP -BLAST
FAN MODEL HT W B C F R RO WEIGHT
LB
DU33HFA 24 3/4 25 1/2 1 1/2 21 18 1/2 12 1/8 17 1/2 —
OPTIONS:
HINGED FAN
PITCHED CURB
INSULATED CURB
UNDERCUT DOOR
FEATURES:
- ROOF MOUNTED FANS
— RESTAURANT MODEL
- UL762
- VARIABLE SPEED CONTROL
INTERNAL WIRING
— WEATHERPROOF DISCONNECT
— THERMAL OVERLOAD PROTECTION SINGLE PHASE)
- HIGH HEAT OPERATION 300 (149T)
EXISTING
SALES
AREA
IIIIICI�( mm III
EXHAUST FANS DIMENSIONAL DATA
EXHAUST FAN
6" MINIMUM
ALL SIDES
SECTION THRU HOOD
SEE FAN DRAWING FOR DETAILS
OFFSET AS REQUIRED
COOKING SURFACE
SECTION VIEW — MODEL 5424—VH1
CEILING
MOUNT 6' -9"
ABOVE FLOOR
HOOD INFORMATION TABLE
i a
AIR BALANCE SCHEDULE
UNIT TAG SUPPLY AIR RETURN AIR OUTSIDE AIR MAKE -UP ` AIR EXHAUST AIR BLDG PRESS.
EC -1 2000 1600 400 400 - 400
PC-2 2000 1600 400 400 - 400
EF -1 - - 650 X50
CEF -1 - - - - 65 -�5
CEF -2 - - - 65 =65
TOTALS 4000 3200 800 S00 1 S(d 20
GENERAL NOTE:
CONTRACTOR TO INSPECT EXISTING MECHANICAL UNITS. REPAIR,
REPLACE DEFECTIVE PARTS, LEAVE IN LIKE NEW CONDITION. CHECK
REFRIGERATION LEVELS AFTER PRESSURE CHECK, RECHARGE IF
REQUIRED, CHEMICALLY CLEAN EVAPORATOR AND CONDENSER COILS.
INSTALL NEW CONDENSATE DRAIN IF REQUIRED. REBALANCE AIR
QUANTITIES TO PROVIDE ADEQUATE OUTSIDE AIR REQUIRED BY CODE
AND TO BALANCE THE SPACE TO A MINIMUM OF +200 CFM.
2. INTERLOCK FAN OPERATION OF "TYPE II EXHAUST HOOD" WITH FC -1
AND FC -2 FAN OPERATION. THE OUTSIDE AIR FROM THE EXISTING
HVAC UNITS SHALL BE USED AS MAKE —UP AIR FOR THE EXHAUST
FANS.
KEYED NOTES:
01 NOT USED
O CONTRACTOR TO INSTALL CAPTIVAIRE VH1 < 54 "X 36" EXHAUST HOOD
ABOVE CONVECTION OVEN (TG7). HOOD TO BE PROVIDED BY GC..
INSTALLED BY ° CONTRACTOR. PROVIDE ALL. 3/8 ALL THREARD ROD
AND HANG ACROSS THREE EXISTING JOISTS WITH UNISTRUT.
® 10" SQUARE DUCT FROM TYPE 11 HOOD TO EXHAUST FAN SHALL BE
SEALED LIQIUD TIGHT.
O4 INSTALL NEW CAPTIVAIRE DU33HFA EXHAUST FAN MOUNTED ON ROOF._
FAN TO BE PROVIDED BY GC. INSTALLED BY CONTRACTOR. FAN IS TO
BE A MINIMUM OF 10 FEET FROM ANY OUTSIDE AIR INTAKES, AND A
MINIMUM OF 40" FROM PARAPET WALLS.
O EXISTING DIFFUSER /GRILLES TO REMAIN. ADJUST DIFFUSERS AS
REQUIRED TO FIT WITHIN CEILING GRID. ALL DIFFUSERS AND GRILLES
SHALL BE CLEANED AND REPAINTED.
® CONTRACTOR SHALL RELOCATE 12"x12" RETURN GRILLE ABOVE THE
FROZEN BEVERAGE DISPENSER. REFER TO ARCHITECTURAL DEMOLITION
PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT
DUCTWORK AS REQUIRED.
O CONTRACTOR SHALL RELOCATE 12 "x12" BATHROOM EXHAUST FAN TO
NEW RESTROOM LOCATION. REFER TO ARCHITECTURAL DEMOLITION
PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT
DUCTWORK AS REQUIRED.
FAN INFORMATION SCHEDULE
Hood Tag Fan Model Mfg. CFM S.P. RPM H.P. Phase Volts
1 EF -1 EXHAUST DU33HFA CAS 650 0.50" 1258 0.33 1 115
AIR REQUIREMENTS
HOOD COOKING EXHAUST RISER HOOD
N0. MODEL LENGTH EXHAUST SIZE CFM/ TOTAL CONST.
QTY. W L RISER S P EXH. CFM
100%
V 2 3 ' O " -- 650 0.25" 650 TYPE
5424 DEG. 430 S/S
O 0
27"
L
i4" .
j
O 0
Hood #
1 S " 18
3 ' C
PLAN VIEW
HOOD PLAN
3' 0.00" LONG 5424VH1
1 EXPIRES 10 -24 -2010
Date Signed: Jun 30, 2009
REVIEWED FOR
CODE COMPLIAN
APPROVED
JUL 15 2009
City of Tukwila
BUILDING DIVISION
FACTORY LOCATED & INSTALLED
HANGER ANGLES (TYPICAL)
.00 "Nom. /3' 0.50 "OD
SACRAMENTO
ENO /NEER /NO
CONSULTANTS
10555 Old Placerville Road
Sacramento, CA 95827 -2503
Phone: (916) 368 -4468
Fax: (916)368 -4490
www.saceng.com
CLEN14
b
ARCO
BP WEST COAST PRODUCTS, LLC
0 fir► %' ^.
.• U
t11 �^
I.
l �•� H G ENG`N
18215 72ND AVENUE SOUTH
KENT, WA 98032
(425)251 -6222
(425)251 -8782 FAX
CML ENGINEERING, LAND PLANNING,
SURVEYING, ENVIRONMENTAL SERVICES
NO. DATE REVISION DESCRIPTION
1i\ 6/22/09 CITY PLANCHWK
/t\
/
11
SEAL:
CONFIDENTIAL IN STATFMFNT:
THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT
COPYRIGHT IN THE MATERIALS 15 OWNED BY GLOBAL
AWANCE. AND ALSO. THAT THE MATERIALS CONTAIN
PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF
GLOBAL AWANCE. ACCORDINGLY. THE RECIPIENT AGREES TO
RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND
AGREES NOT m DISCLOSE THESE MATERIALS TO ANY OTHER
PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE
MATERIALS. THE RECIPIENT AGREES TO USE 111E
MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH
GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE.
AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO
GLOBAL AWANCE EITHER UPON COMPLETION OF 111E
INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL
AWANCE. WHICHEVER COMES FIRST.
DEVELOPMENT INFORMATION:
2009 RETROFIT
BACKCOURT
RANCH STYLE
SITE ADDRESS:
5800 SOUTHCENTER BLVD.
@I.5
TUKWILA, WASHINGTON
FAC 83098
DESIGNED BY: EH AWANCE Z &DM:
CHECKED BY: RH BP REPM:
DRAWN BY:
CSC
AWANCE PM:
VERSION: PROJECT NO:
1975.75
DRAWING TITLE:
MECHANICAL PLAN,
SCHEDULES, NOTES, &
DETAILS
SHEET NO:
M
Akil.
1r
r fr
.c. O ihn JL
o
MAX
IF
1
1
DUCTWORK BETWEEN EXHAUST RISER
ON HOOD AND FAN (BY OTHERS)
EXHAUST FAN DETAIL
SCALE: 1/4"=1'-0"
CURB ASSEMBLIES
NO FAN ITEM SIZE
1 # 1 Curb 19.500 "W x 19.500 "L x 22.000 "H Vented
UPBLAST EXHAUST FAN
MODEL #DU33HFA (95 LBS EACH)
BACKROOM
II H1 11 II II
EXISTING COVERED
TRASH ENCLOSURE
MIECHANICAL PLAN
ampm COFFEE
25 1/2" DIA
12 1/8"
DIA
21" SQ.
t�lf�I 11F-1
1 H ILJ� 1
EXISTING
STORAGE
1
THE TRANSITION BETWEEN
THE DUCTWORK AND FAN
BASE SHOULD BE EQUAL
TO OR GREATER THAN R
(DIA) DIMENSION ///i
ROOF OPENING
DIMENSIONS 18" X
18" 18 18" 18','
amca
CERTIFIED
RATINGS /.
A I R
SO AND
VENTED CURB
ETL LISTED PER UL 705
20 GAUGE ALUMINIZED
STEEL CONSTRUCTION
3" CONTINUOUS
FLASHING
NEW UNISEX
REST ROOM
EXISTING STORAGE
CONTAINER
DUL /HFA DIRECT DRIVE
CENTRIFUGAL UP -BLAST
FAN MODEL HT W B C F R RO WEIGHT
LB
DU33HFA 24 3/4 25 1/2 1 1/2 21 18 1/2 12 1/8 17 1/2 —
OPTIONS:
HINGED FAN
PITCHED CURB
INSULATED CURB
UNDERCUT DOOR
FEATURES:
- ROOF MOUNTED FANS
— RESTAURANT MODEL
- UL762
- VARIABLE SPEED CONTROL
INTERNAL WIRING
— WEATHERPROOF DISCONNECT
— THERMAL OVERLOAD PROTECTION SINGLE PHASE)
- HIGH HEAT OPERATION 300 (149T)
EXISTING
SALES
AREA
IIIIICI�( mm III
EXHAUST FANS DIMENSIONAL DATA
EXHAUST FAN
6" MINIMUM
ALL SIDES
SECTION THRU HOOD
SEE FAN DRAWING FOR DETAILS
OFFSET AS REQUIRED
COOKING SURFACE
SECTION VIEW — MODEL 5424—VH1
CEILING
MOUNT 6' -9"
ABOVE FLOOR
HOOD INFORMATION TABLE
i a
AIR BALANCE SCHEDULE
UNIT TAG SUPPLY AIR RETURN AIR OUTSIDE AIR MAKE -UP ` AIR EXHAUST AIR BLDG PRESS.
EC -1 2000 1600 400 400 - 400
PC-2 2000 1600 400 400 - 400
EF -1 - - 650 X50
CEF -1 - - - - 65 -�5
CEF -2 - - - 65 =65
TOTALS 4000 3200 800 S00 1 S(d 20
GENERAL NOTE:
CONTRACTOR TO INSPECT EXISTING MECHANICAL UNITS. REPAIR,
REPLACE DEFECTIVE PARTS, LEAVE IN LIKE NEW CONDITION. CHECK
REFRIGERATION LEVELS AFTER PRESSURE CHECK, RECHARGE IF
REQUIRED, CHEMICALLY CLEAN EVAPORATOR AND CONDENSER COILS.
INSTALL NEW CONDENSATE DRAIN IF REQUIRED. REBALANCE AIR
QUANTITIES TO PROVIDE ADEQUATE OUTSIDE AIR REQUIRED BY CODE
AND TO BALANCE THE SPACE TO A MINIMUM OF +200 CFM.
2. INTERLOCK FAN OPERATION OF "TYPE II EXHAUST HOOD" WITH FC -1
AND FC -2 FAN OPERATION. THE OUTSIDE AIR FROM THE EXISTING
HVAC UNITS SHALL BE USED AS MAKE —UP AIR FOR THE EXHAUST
FANS.
KEYED NOTES:
01 NOT USED
O CONTRACTOR TO INSTALL CAPTIVAIRE VH1 < 54 "X 36" EXHAUST HOOD
ABOVE CONVECTION OVEN (TG7). HOOD TO BE PROVIDED BY GC..
INSTALLED BY ° CONTRACTOR. PROVIDE ALL. 3/8 ALL THREARD ROD
AND HANG ACROSS THREE EXISTING JOISTS WITH UNISTRUT.
® 10" SQUARE DUCT FROM TYPE 11 HOOD TO EXHAUST FAN SHALL BE
SEALED LIQIUD TIGHT.
O4 INSTALL NEW CAPTIVAIRE DU33HFA EXHAUST FAN MOUNTED ON ROOF._
FAN TO BE PROVIDED BY GC. INSTALLED BY CONTRACTOR. FAN IS TO
BE A MINIMUM OF 10 FEET FROM ANY OUTSIDE AIR INTAKES, AND A
MINIMUM OF 40" FROM PARAPET WALLS.
O EXISTING DIFFUSER /GRILLES TO REMAIN. ADJUST DIFFUSERS AS
REQUIRED TO FIT WITHIN CEILING GRID. ALL DIFFUSERS AND GRILLES
SHALL BE CLEANED AND REPAINTED.
® CONTRACTOR SHALL RELOCATE 12"x12" RETURN GRILLE ABOVE THE
FROZEN BEVERAGE DISPENSER. REFER TO ARCHITECTURAL DEMOLITION
PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT
DUCTWORK AS REQUIRED.
O CONTRACTOR SHALL RELOCATE 12 "x12" BATHROOM EXHAUST FAN TO
NEW RESTROOM LOCATION. REFER TO ARCHITECTURAL DEMOLITION
PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT
DUCTWORK AS REQUIRED.
FAN INFORMATION SCHEDULE
Hood Tag Fan Model Mfg. CFM S.P. RPM H.P. Phase Volts
1 EF -1 EXHAUST DU33HFA CAS 650 0.50" 1258 0.33 1 115
AIR REQUIREMENTS
HOOD COOKING EXHAUST RISER HOOD
N0. MODEL LENGTH EXHAUST SIZE CFM/ TOTAL CONST.
QTY. W L RISER S P EXH. CFM
100%
V 2 3 ' O " -- 650 0.25" 650 TYPE
5424 DEG. 430 S/S
O 0
27"
L
i4" .
j
O 0
Hood #
1 S " 18
3 ' C
PLAN VIEW
HOOD PLAN
3' 0.00" LONG 5424VH1
1 EXPIRES 10 -24 -2010
Date Signed: Jun 30, 2009
REVIEWED FOR
CODE COMPLIAN
APPROVED
JUL 15 2009
City of Tukwila
BUILDING DIVISION
FACTORY LOCATED & INSTALLED
HANGER ANGLES (TYPICAL)
.00 "Nom. /3' 0.50 "OD
SACRAMENTO
ENO /NEER /NO
CONSULTANTS
10555 Old Placerville Road
Sacramento, CA 95827 -2503
Phone: (916) 368 -4468
Fax: (916)368 -4490
www.saceng.com
CLEN14
b
ARCO
BP WEST COAST PRODUCTS, LLC
0 fir► %' ^.
.• U
t11 �^
I.
l �•� H G ENG`N
18215 72ND AVENUE SOUTH
KENT, WA 98032
(425)251 -6222
(425)251 -8782 FAX
CML ENGINEERING, LAND PLANNING,
SURVEYING, ENVIRONMENTAL SERVICES
NO. DATE REVISION DESCRIPTION
1i\ 6/22/09 CITY PLANCHWK
/t\
/
11
SEAL:
CONFIDENTIAL IN STATFMFNT:
THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT
COPYRIGHT IN THE MATERIALS 15 OWNED BY GLOBAL
AWANCE. AND ALSO. THAT THE MATERIALS CONTAIN
PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF
GLOBAL AWANCE. ACCORDINGLY. THE RECIPIENT AGREES TO
RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND
AGREES NOT m DISCLOSE THESE MATERIALS TO ANY OTHER
PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE
MATERIALS. THE RECIPIENT AGREES TO USE 111E
MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH
GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE.
AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO
GLOBAL AWANCE EITHER UPON COMPLETION OF 111E
INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL
AWANCE. WHICHEVER COMES FIRST.
DEVELOPMENT INFORMATION:
2009 RETROFIT
BACKCOURT
RANCH STYLE
SITE ADDRESS:
5800 SOUTHCENTER BLVD.
@I.5
TUKWILA, WASHINGTON
FAC 83098
DESIGNED BY: EH AWANCE Z &DM:
CHECKED BY: RH BP REPM:
DRAWN BY:
CSC
AWANCE PM:
VERSION: PROJECT NO:
1975.75
DRAWING TITLE:
MECHANICAL PLAN,
SCHEDULES, NOTES, &
DETAILS
SHEET NO:
M
MAX
IF
1
DUCTWORK BETWEEN EXHAUST RISER
ON HOOD AND FAN (BY OTHERS)
EXHAUST FAN DETAIL
SCALE: 1/4"=1'-0"
CURB ASSEMBLIES
NO FAN ITEM SIZE
1 # 1 Curb 19.500 "W x 19.500 "L x 22.000 "H Vented
UPBLAST EXHAUST FAN
MODEL #DU33HFA (95 LBS EACH)
BACKROOM
II H1 11 II II
EXISTING COVERED
TRASH ENCLOSURE
MIECHANICAL PLAN
ampm COFFEE
25 1/2" DIA
12 1/8"
DIA
21" SQ.
t�lf�I 11F-1
1 H ILJ� 1
EXISTING
STORAGE
1
THE TRANSITION BETWEEN
THE DUCTWORK AND FAN
BASE SHOULD BE EQUAL
TO OR GREATER THAN R
(DIA) DIMENSION ///i
ROOF OPENING
DIMENSIONS 18" X
18" 18 18" 18','
amca
CERTIFIED
RATINGS /.
A I R
SO AND
VENTED CURB
ETL LISTED PER UL 705
20 GAUGE ALUMINIZED
STEEL CONSTRUCTION
3" CONTINUOUS
FLASHING
NEW UNISEX
REST ROOM
EXISTING STORAGE
CONTAINER
DUL /HFA DIRECT DRIVE
CENTRIFUGAL UP -BLAST
FAN MODEL HT W B C F R RO WEIGHT
LB
DU33HFA 24 3/4 25 1/2 1 1/2 21 18 1/2 12 1/8 17 1/2 —
OPTIONS:
HINGED FAN
PITCHED CURB
INSULATED CURB
UNDERCUT DOOR
FEATURES:
- ROOF MOUNTED FANS
— RESTAURANT MODEL
- UL762
- VARIABLE SPEED CONTROL
INTERNAL WIRING
— WEATHERPROOF DISCONNECT
— THERMAL OVERLOAD PROTECTION SINGLE PHASE)
- HIGH HEAT OPERATION 300 (149T)
EXISTING
SALES
AREA
IIIIICI�( mm III
EXHAUST FANS DIMENSIONAL DATA
EXHAUST FAN
6" MINIMUM
ALL SIDES
SECTION THRU HOOD
SEE FAN DRAWING FOR DETAILS
OFFSET AS REQUIRED
COOKING SURFACE
SECTION VIEW — MODEL 5424—VH1
CEILING
MOUNT 6' -9"
ABOVE FLOOR
HOOD INFORMATION TABLE
i a
AIR BALANCE SCHEDULE
UNIT TAG SUPPLY AIR RETURN AIR OUTSIDE AIR MAKE -UP ` AIR EXHAUST AIR BLDG PRESS.
EC -1 2000 1600 400 400 - 400
PC-2 2000 1600 400 400 - 400
EF -1 - - 650 X50
CEF -1 - - - - 65 -�5
CEF -2 - - - 65 =65
TOTALS 4000 3200 800 S00 1 S(d 20
GENERAL NOTE:
CONTRACTOR TO INSPECT EXISTING MECHANICAL UNITS. REPAIR,
REPLACE DEFECTIVE PARTS, LEAVE IN LIKE NEW CONDITION. CHECK
REFRIGERATION LEVELS AFTER PRESSURE CHECK, RECHARGE IF
REQUIRED, CHEMICALLY CLEAN EVAPORATOR AND CONDENSER COILS.
INSTALL NEW CONDENSATE DRAIN IF REQUIRED. REBALANCE AIR
QUANTITIES TO PROVIDE ADEQUATE OUTSIDE AIR REQUIRED BY CODE
AND TO BALANCE THE SPACE TO A MINIMUM OF +200 CFM.
2. INTERLOCK FAN OPERATION OF "TYPE II EXHAUST HOOD" WITH FC -1
AND FC -2 FAN OPERATION. THE OUTSIDE AIR FROM THE EXISTING
HVAC UNITS SHALL BE USED AS MAKE —UP AIR FOR THE EXHAUST
FANS.
KEYED NOTES:
01 NOT USED
O CONTRACTOR TO INSTALL CAPTIVAIRE VH1 < 54 "X 36" EXHAUST HOOD
ABOVE CONVECTION OVEN (TG7). HOOD TO BE PROVIDED BY GC..
INSTALLED BY ° CONTRACTOR. PROVIDE ALL. 3/8 ALL THREARD ROD
AND HANG ACROSS THREE EXISTING JOISTS WITH UNISTRUT.
® 10" SQUARE DUCT FROM TYPE 11 HOOD TO EXHAUST FAN SHALL BE
SEALED LIQIUD TIGHT.
O4 INSTALL NEW CAPTIVAIRE DU33HFA EXHAUST FAN MOUNTED ON ROOF._
FAN TO BE PROVIDED BY GC. INSTALLED BY CONTRACTOR. FAN IS TO
BE A MINIMUM OF 10 FEET FROM ANY OUTSIDE AIR INTAKES, AND A
MINIMUM OF 40" FROM PARAPET WALLS.
O EXISTING DIFFUSER /GRILLES TO REMAIN. ADJUST DIFFUSERS AS
REQUIRED TO FIT WITHIN CEILING GRID. ALL DIFFUSERS AND GRILLES
SHALL BE CLEANED AND REPAINTED.
® CONTRACTOR SHALL RELOCATE 12"x12" RETURN GRILLE ABOVE THE
FROZEN BEVERAGE DISPENSER. REFER TO ARCHITECTURAL DEMOLITION
PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT
DUCTWORK AS REQUIRED.
O CONTRACTOR SHALL RELOCATE 12 "x12" BATHROOM EXHAUST FAN TO
NEW RESTROOM LOCATION. REFER TO ARCHITECTURAL DEMOLITION
PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT
DUCTWORK AS REQUIRED.
FAN INFORMATION SCHEDULE
Hood Tag Fan Model Mfg. CFM S.P. RPM H.P. Phase Volts
1 EF -1 EXHAUST DU33HFA CAS 650 0.50" 1258 0.33 1 115
AIR REQUIREMENTS
HOOD COOKING EXHAUST RISER HOOD
N0. MODEL LENGTH EXHAUST SIZE CFM/ TOTAL CONST.
QTY. W L RISER S P EXH. CFM
100%
V 2 3 ' O " -- 650 0.25" 650 TYPE
5424 DEG. 430 S/S
O 0
27"
L
i4" .
j
O 0
Hood #
1 S " 18
3 ' C
PLAN VIEW
HOOD PLAN
3' 0.00" LONG 5424VH1
1 EXPIRES 10 -24 -2010
Date Signed: Jun 30, 2009
REVIEWED FOR
CODE COMPLIAN
APPROVED
JUL 15 2009
City of Tukwila
BUILDING DIVISION
FACTORY LOCATED & INSTALLED
HANGER ANGLES (TYPICAL)
.00 "Nom. /3' 0.50 "OD
SACRAMENTO
ENO /NEER /NO
CONSULTANTS
10555 Old Placerville Road
Sacramento, CA 95827 -2503
Phone: (916) 368 -4468
Fax: (916)368 -4490
www.saceng.com
CLEN14
b
ARCO
BP WEST COAST PRODUCTS, LLC
0 fir► %' ^.
.• U
t11 �^
I.
l �•� H G ENG`N
18215 72ND AVENUE SOUTH
KENT, WA 98032
(425)251 -6222
(425)251 -8782 FAX
CML ENGINEERING, LAND PLANNING,
SURVEYING, ENVIRONMENTAL SERVICES
NO. DATE REVISION DESCRIPTION
1i\ 6/22/09 CITY PLANCHWK
/t\
/
11
SEAL:
CONFIDENTIAL IN STATFMFNT:
THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT
COPYRIGHT IN THE MATERIALS 15 OWNED BY GLOBAL
AWANCE. AND ALSO. THAT THE MATERIALS CONTAIN
PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF
GLOBAL AWANCE. ACCORDINGLY. THE RECIPIENT AGREES TO
RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND
AGREES NOT m DISCLOSE THESE MATERIALS TO ANY OTHER
PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE
MATERIALS. THE RECIPIENT AGREES TO USE 111E
MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH
GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE.
AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO
GLOBAL AWANCE EITHER UPON COMPLETION OF 111E
INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL
AWANCE. WHICHEVER COMES FIRST.
DEVELOPMENT INFORMATION:
2009 RETROFIT
BACKCOURT
RANCH STYLE
SITE ADDRESS:
5800 SOUTHCENTER BLVD.
@I.5
TUKWILA, WASHINGTON
FAC 83098
DESIGNED BY: EH AWANCE Z &DM:
CHECKED BY: RH BP REPM:
DRAWN BY:
CSC
AWANCE PM:
VERSION: PROJECT NO:
1975.75
DRAWING TITLE:
MECHANICAL PLAN,
SCHEDULES, NOTES, &
DETAILS
SHEET NO:
M
IF
1
1
DUCTWORK BETWEEN EXHAUST RISER
ON HOOD AND FAN (BY OTHERS)
EXHAUST FAN DETAIL
SCALE: 1/4"=1'-0"
CURB ASSEMBLIES
NO FAN ITEM SIZE
1 # 1 Curb 19.500 "W x 19.500 "L x 22.000 "H Vented
UPBLAST EXHAUST FAN
MODEL #DU33HFA (95 LBS EACH)
BACKROOM
II H1 11 II II
EXISTING COVERED
TRASH ENCLOSURE
MIECHANICAL PLAN
ampm COFFEE
25 1/2" DIA
12 1/8"
DIA
21" SQ.
t�lf�I 11F-1
1 H ILJ� 1
EXISTING
STORAGE
1
THE TRANSITION BETWEEN
THE DUCTWORK AND FAN
BASE SHOULD BE EQUAL
TO OR GREATER THAN R
(DIA) DIMENSION ///i
ROOF OPENING
DIMENSIONS 18" X
18" 18 18" 18','
amca
CERTIFIED
RATINGS /.
A I R
SO AND
VENTED CURB
ETL LISTED PER UL 705
20 GAUGE ALUMINIZED
STEEL CONSTRUCTION
3" CONTINUOUS
FLASHING
NEW UNISEX
REST ROOM
EXISTING STORAGE
CONTAINER
DUL /HFA DIRECT DRIVE
CENTRIFUGAL UP -BLAST
FAN MODEL HT W B C F R RO WEIGHT
LB
DU33HFA 24 3/4 25 1/2 1 1/2 21 18 1/2 12 1/8 17 1/2 —
OPTIONS:
HINGED FAN
PITCHED CURB
INSULATED CURB
UNDERCUT DOOR
FEATURES:
- ROOF MOUNTED FANS
— RESTAURANT MODEL
- UL762
- VARIABLE SPEED CONTROL
INTERNAL WIRING
— WEATHERPROOF DISCONNECT
— THERMAL OVERLOAD PROTECTION SINGLE PHASE)
- HIGH HEAT OPERATION 300 (149T)
EXISTING
SALES
AREA
IIIIICI�( mm III
EXHAUST FANS DIMENSIONAL DATA
EXHAUST FAN
6" MINIMUM
ALL SIDES
SECTION THRU HOOD
SEE FAN DRAWING FOR DETAILS
OFFSET AS REQUIRED
COOKING SURFACE
SECTION VIEW — MODEL 5424—VH1
CEILING
MOUNT 6' -9"
ABOVE FLOOR
HOOD INFORMATION TABLE
i a
AIR BALANCE SCHEDULE
UNIT TAG SUPPLY AIR RETURN AIR OUTSIDE AIR MAKE -UP ` AIR EXHAUST AIR BLDG PRESS.
EC -1 2000 1600 400 400 - 400
PC-2 2000 1600 400 400 - 400
EF -1 - - 650 X50
CEF -1 - - - - 65 -�5
CEF -2 - - - 65 =65
TOTALS 4000 3200 800 S00 1 S(d 20
GENERAL NOTE:
CONTRACTOR TO INSPECT EXISTING MECHANICAL UNITS. REPAIR,
REPLACE DEFECTIVE PARTS, LEAVE IN LIKE NEW CONDITION. CHECK
REFRIGERATION LEVELS AFTER PRESSURE CHECK, RECHARGE IF
REQUIRED, CHEMICALLY CLEAN EVAPORATOR AND CONDENSER COILS.
INSTALL NEW CONDENSATE DRAIN IF REQUIRED. REBALANCE AIR
QUANTITIES TO PROVIDE ADEQUATE OUTSIDE AIR REQUIRED BY CODE
AND TO BALANCE THE SPACE TO A MINIMUM OF +200 CFM.
2. INTERLOCK FAN OPERATION OF "TYPE II EXHAUST HOOD" WITH FC -1
AND FC -2 FAN OPERATION. THE OUTSIDE AIR FROM THE EXISTING
HVAC UNITS SHALL BE USED AS MAKE —UP AIR FOR THE EXHAUST
FANS.
KEYED NOTES:
01 NOT USED
O CONTRACTOR TO INSTALL CAPTIVAIRE VH1 < 54 "X 36" EXHAUST HOOD
ABOVE CONVECTION OVEN (TG7). HOOD TO BE PROVIDED BY GC..
INSTALLED BY ° CONTRACTOR. PROVIDE ALL. 3/8 ALL THREARD ROD
AND HANG ACROSS THREE EXISTING JOISTS WITH UNISTRUT.
® 10" SQUARE DUCT FROM TYPE 11 HOOD TO EXHAUST FAN SHALL BE
SEALED LIQIUD TIGHT.
O4 INSTALL NEW CAPTIVAIRE DU33HFA EXHAUST FAN MOUNTED ON ROOF._
FAN TO BE PROVIDED BY GC. INSTALLED BY CONTRACTOR. FAN IS TO
BE A MINIMUM OF 10 FEET FROM ANY OUTSIDE AIR INTAKES, AND A
MINIMUM OF 40" FROM PARAPET WALLS.
O EXISTING DIFFUSER /GRILLES TO REMAIN. ADJUST DIFFUSERS AS
REQUIRED TO FIT WITHIN CEILING GRID. ALL DIFFUSERS AND GRILLES
SHALL BE CLEANED AND REPAINTED.
® CONTRACTOR SHALL RELOCATE 12"x12" RETURN GRILLE ABOVE THE
FROZEN BEVERAGE DISPENSER. REFER TO ARCHITECTURAL DEMOLITION
PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT
DUCTWORK AS REQUIRED.
O CONTRACTOR SHALL RELOCATE 12 "x12" BATHROOM EXHAUST FAN TO
NEW RESTROOM LOCATION. REFER TO ARCHITECTURAL DEMOLITION
PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT
DUCTWORK AS REQUIRED.
FAN INFORMATION SCHEDULE
Hood Tag Fan Model Mfg. CFM S.P. RPM H.P. Phase Volts
1 EF -1 EXHAUST DU33HFA CAS 650 0.50" 1258 0.33 1 115
AIR REQUIREMENTS
HOOD COOKING EXHAUST RISER HOOD
N0. MODEL LENGTH EXHAUST SIZE CFM/ TOTAL CONST.
QTY. W L RISER S P EXH. CFM
100%
V 2 3 ' O " -- 650 0.25" 650 TYPE
5424 DEG. 430 S/S
O 0
27"
L
i4" .
j
O 0
Hood #
1 S " 18
3 ' C
PLAN VIEW
HOOD PLAN
3' 0.00" LONG 5424VH1
1 EXPIRES 10 -24 -2010
Date Signed: Jun 30, 2009
REVIEWED FOR
CODE COMPLIAN
APPROVED
JUL 15 2009
City of Tukwila
BUILDING DIVISION
FACTORY LOCATED & INSTALLED
HANGER ANGLES (TYPICAL)
.00 "Nom. /3' 0.50 "OD
SACRAMENTO
ENO /NEER /NO
CONSULTANTS
10555 Old Placerville Road
Sacramento, CA 95827 -2503
Phone: (916) 368 -4468
Fax: (916)368 -4490
www.saceng.com
CLEN14
b
ARCO
BP WEST COAST PRODUCTS, LLC
0 fir► %' ^.
.• U
t11 �^
I.
l �•� H G ENG`N
18215 72ND AVENUE SOUTH
KENT, WA 98032
(425)251 -6222
(425)251 -8782 FAX
CML ENGINEERING, LAND PLANNING,
SURVEYING, ENVIRONMENTAL SERVICES
NO. DATE REVISION DESCRIPTION
1i\ 6/22/09 CITY PLANCHWK
/t\
/
11
SEAL:
CONFIDENTIAL IN STATFMFNT:
THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT
COPYRIGHT IN THE MATERIALS 15 OWNED BY GLOBAL
AWANCE. AND ALSO. THAT THE MATERIALS CONTAIN
PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF
GLOBAL AWANCE. ACCORDINGLY. THE RECIPIENT AGREES TO
RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND
AGREES NOT m DISCLOSE THESE MATERIALS TO ANY OTHER
PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE
MATERIALS. THE RECIPIENT AGREES TO USE 111E
MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH
GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE.
AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO
GLOBAL AWANCE EITHER UPON COMPLETION OF 111E
INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL
AWANCE. WHICHEVER COMES FIRST.
DEVELOPMENT INFORMATION:
2009 RETROFIT
BACKCOURT
RANCH STYLE
SITE ADDRESS:
5800 SOUTHCENTER BLVD.
@I.5
TUKWILA, WASHINGTON
FAC 83098
DESIGNED BY: EH AWANCE Z &DM:
CHECKED BY: RH BP REPM:
DRAWN BY:
CSC
AWANCE PM:
VERSION: PROJECT NO:
1975.75
DRAWING TITLE:
MECHANICAL PLAN,
SCHEDULES, NOTES, &
DETAILS
SHEET NO:
M