Loading...
HomeMy WebLinkAboutPermit M09-066 - ARCO AM/PMARCO AM /PM 5800 SOUTHCENTER BL M09 -066 Parcel No.: Address: Suite No: doc: IMC -10/06 City(If Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1157200352 5800 SOUTHCENTER BL TUKW Tenant: Name: ARCO AM /PM NO 83098 Address: 5800 SOUTHCENTER BL , TUKWILA WA Owner: Name: YAMASHITA SUSIE Address: YOSHINO INC , 5800 SOUTHCENTER BLVD Contact Person: Name: ALEXIA INIGUES Address: 18215 72 AV S , KENT WA Contractor: Name: JOE PARK CONSTRUCTION LLC Address: PO BOX 527 , YAKIMA WA Contractor License No: JOEPACL994DE DESCRIPTION OF WORK: INSTALL TYPE II EXHAUST HOOD OVER CONVECTION WITH THRU -ROOF EXHAUST FAN. RELOCATE EXHAUST FAN AND INSTALL (2) NEW. RELOCATE AIR SUPPLY /RETURN AIR GRILL TO ACCOMMODATE NEW HOOD LOCATION. PROVIDE NEW DIFFUSER IN NEW RESTROOM. Value of Mechanical: $5,500.00 Type of Fire Protection: NONE Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT Fees Collected: $242.81 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 2 0 1 0 0 * *continued on next page ** M09 -066 a Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 251 -6222 Phone: (509)452 -5122 Expiration Date: 03/05/2011 M09 -066 11/02/2009 05/01/2010 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 - 15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 1 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 11 -02 -2009 Permit Center Authorized Signature: I hereby certify that I have read an ex ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be compli wit , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform ce of work. I am authorized to sign and obtain this mechanical permit. �/ �7 n Signature: Date:��u Cam Print Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Permit Number: MO9 -066 Issue Date: 11/02/2009 Permit Expires On: 05/01/2010 Date: 11 1 021 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -10/06 M09 -066 Printed: 11 -02 -2009 Parcel No.: 1157200352 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 5800 SOUTHCENTER BL TUHW ARCO AM /PM NO 83098 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M09 -066 ISSUED 06/08/2009 11/02/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M09 -066 Printed: 11 -02 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10!06 Date• M09 -066 Printed: 11 -02 -2009 SITE LOCATION Tenant Name: CITY OF TUKWIL• Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Site Address: 5800 Southcenter Boulevard, Tukwila, WA 98188 Suite Number: ARCO AM /PM Facility No. 83098 Property Owners Name: BP West Coast Products LLC Mailing Address: 4 Centerpointe Drive CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Alexia Inigues, Barghausen Consulting Engineers, Inc. Mailing Address: 18215 = 72nd Avenue South E -Mail Address: ainigues @barghausen.com Company Name: Barghausen Consulting Engineers, Inc. Mailing Address: 18215 - 72nd Avenue South Contact Person:_ - Caryl Mattson E -Mail Address: cmattson @barghausen.com Company Name: Barghausen Consulting Engineers, Inc. Applications and plans must be complete in order to be accepted for plan review. Applications Will not be accepted through the mail or by fax. * *Please Print ** Mailing Address: 18215 - 72nd Avenue South Contact Person: Caryl Mattson E -Mail Address: cmattson @barghausen.com H:\Applications\Forms- Applications On Line\2009 Applications \I-2009 - Mechanical Permit Applicaiion.doc Revised: 1 -2009 bh MECHANICAL PERMIT APPLICATION Mechanical Permit No. Project No. (For office use only) 01-- King Co Assessor's Tax No.: 115720 -0352 La Palma City Day Telephone: (425) 261 -6222 Kent WA City State Fax Number: (425) 251 -8782 MECHANICAL CONTRACTOR INFORMATION Company Name. Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: v J City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Kent WA City State Zip Day Telephone: (425) 251 -6222 Fax Number: (425) 251 -8782 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Kent City Day Telephone: Fax Number: New Tenant: CA Floor: Yes VI -No State 90623 Zip 98032 Zip 98032 WA 98032 State Zip (425) 251 -6222 (425) 251 =8782 Page I of2 1975.031.pdf.doc Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: 0 -3 HP /100,000 BTU Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper Furnace >100K BTU Evaporator Cooler Diffuser 1 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct _ 2 Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct 1 Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Valuation of Project (contractor's bid price): $ 5,500 Scope of Work (please provide detailed information): install type II exhaust hood_over convection over with thru -roof exhaust fan. relocate exhaust fan and install 2 new. relocate air supply /return air grill to accommodate new hood location. provide new diffuser in new rest room. Fuel Type: Electric • Use: Residential: New U Replacement Commercial: New ❑ Replacement Indicate type of mechanical work being installed and the quantity below: Gas ❑ Other: PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: cr/o7 Print Name: 4fr)(la J V / oP$ Day Telephone: 1 /Z9 9 ' 2 5 lr/ 2 - 22 - . � Kd Mailing Address: ga 17 °� ie/7 / 16&'] -7 city WA state Zip Signature: Date Application Accepted: ❑ Date: Date Application Expires: 01 k H:\Applications\Forms- Applications On Line\2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Staff Initials: i gc 2 of 2 1975.031.pdf.doc Parcel No.: 1157200352 Permit Number: M09 -066 Address: 5800 SOUTHCENTER BL TUKW Status: APPROVED Suite No: Applied Date: 06/08/2009 Applicant: ARCO AM /PM NO 83098 Issue Date: Receipt No.: R09 -01719 Initials: User ID: Payee: JEM 1165 ACCOUNT ITEM LIST: Description JOE PARK CONSTRUCTION LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 6077 242.81 Authorization No. MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT • Payment Amount: $242.81 Account Code Current Pmts 000.322.102.00.00 194.25 000.345.830 48.56 Total: $242.81 Payment Date: 11/02/2009 01:30 PM Balance: $0.00 PAYMENT RECEIVED doc: Receipt -06 Printed: 11 -02 -2009 Proj t: • / WOP An'1 /491 Type of Inspection: /i/ A/4 Address: Date Called: Special Instructions: Date Wanted? / // , 55. P.m. Requester: Phone No: Receipt No.: r� i INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 V Approved per applicable codes. Corrections required prior to approval. / COMMENTS: p Aii . .`r 6A LA Insp ctor: A Date: i II ❑ $60.00 REINSPECTION FEE REQUIRED. Pri r to inspection, fee must be paid at 6300.Southcenter�Blvd., Suite 100. Call to schedule reinspection. Date: COMMENTS: Type of spection: A ii &H -� 41 11) A eee9, yPXin A -, ) t f- (--- 1 1 Special Instructions: 79 )<Lv' (A5r — ca 1 A4 Requester: Phone No: 7 2) N A.t s p e -c .( ,) 4 7>.1£ A-,-r- .- ja S G, — AR r ,)L- �-,,. , c ez,r A ke21 r 'I., ( L),..ip i a s[ . • Project: 4 /1 (Po A n1 /pin Type of spection: A ii &H -� 41 Address: 8800 l ,'6 — Date Called: Special Instructions: Date Wanted: /y / / / /, P.m. Requester: Phone No: *-1 INSPECTION RECORD Retain a copy with permit 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. Inspector: d Corrections required prior to approval. Date: $60.00 REINSPECTION FEE - REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 11 -02 -2009 ALEXIA INIGUES 18215 72 AV S KENT WA 98032 RE: Permit Application No. M09 -066 5800 SOUTHCENTER BL TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 06/08/2009, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 12/05/2009. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M09 -066 0 City of Tukwila Department of Community Development '<„i.P 'Z,,,...ii, • Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Bill Rambo, Permit Technician City of Tukwila Community Development 6300 Southcenter Boulevard, STE #100 Tukwila, WA 98188 • • July 8, 2009 CIVIL ENGINEERING, LAND PLANNING, SURVEYING RE: Response to Comments Permits #PG09 -057 / #M09 -066 / #D09 -096 / PW Comments ARCO AM /PM Interior Retrofit 5800 Southcenter Boulevard, Tukwila, Washington ARCO FAC No. 83098 (6155) / Our Job No. 1975.75 Dear Bill: We have revised the plans and technical documents for the above - referenced permits and in accordance with the comment letters listed below. Although no revisions were required for the Electrical plans (E1.1- E1.4), we are submitting two (2) complete revised sets of those as well due to other department reviews. Accordingly, enclosed are the following documents for your review and approval: 1. Plumbing Review: 1' a) Two (2) REVISED Plumbing Drawings sheet P1.1 b) One (1) City of Tukwila Revisions Submittal Cover Sheet for PG09 -057 c) One (1) copy of Plumbing Permit Correction Letter #1, dated June 18, 2009 2. Mechanical Review: J/ O '1 —01,4 a) Two (2) REVISED Mechanical Drawings sheet M1.1 b) One (1) City of Tukwila Revisions Submittal Cover Sheet for M09 -066 c) One (I) copy of Mechanical Permit Correction Letter #1, dated June 15, 2009 3. Development / Building Review: mot --D't a) Four (4) complete REVISED Building Plan Sets b) One (1) City of Tukwila Revisions Submittal Cover Sheet for D09 -096 c) One (1) copy of Development Permit/ Building Correction Letter #1, dated June 22, 2009 4. Public Works Review: iv 0 `� 5 a) Four (4) Plan Sheets for Installation of Reduced Pressure Principle Assembly (RPPA) sheet AU 1.1. 18215 72ND AVENUE SOUTH KENT, WA 98032 (425) 251 -6222 (425) 251 -8782 FAX BRANCH OFFICES • OLYMPIA, WA 0 TACOMA, WA • CONCORD, CA 0 TEMECULA, CA www.barahausen.com • • Bill Rambo, Permit Technician July 8, 2009 City of Tukwila Community Development -2- b) One (1) Type C Permit Fee Construction Cost Estimate for Backflow Installation, prepared by a licensed Engineer (sealed) c) One (1) copy of Public Works Request for compliance with cross - connection control program The following outline provides each of your comments in italics exactly as written, along with a narrative response describing how each comment was addressed: Plumbing Comments: June 12, 2009 by Allen Johannesson, Plans Examiner (206) 433 - 7163 1. The door opening into the bathroom in front of the sink does not meet accessibility for 60 inch minimum maneuvering clearances at doors. Also doors shall not swing into the clear flood space of any fixture. Please revise the floor plan for the bathroom where the door and fixtures shall be placed to meet accessibility clear floor space and maneuvering requirements. (ANSI 404.2.3 & 1004.11.1.1) Response: Interior door to restroom has been reduced to 34" wide, lavatory has been rotated and new exterior wall was pushed out a few inches to accommodate the required space, see sheet A1.1. Mechanical Comments: June 10, 2009 by Allen Johannesson, Plans Examiner (206) 433 - 7163 1. Makeup air shall be required for the new Type II duct. Makeup air shall be supplied during the operation of commercial kitchen exhaust systems that are provided for commercial cooking appliances. The amount of makeup air supplied shall be approximately equal to the amount of exhaust air. The mechanical makeup air and exhaust system shall be electrically interlocked to ensure that makeup air is provided whenever the exhaust system is in operation. The amount of makeup air shall be approximately equal to the amount of exhaust air and not reduce the effectiveness of the exhaust air. The temperature differential between makeup air and the air in the conditioned space shall not exceed 10 degrees. Identify provisions on the plan with relative documentation for a makeup air system that is electronically interlocked with the new Type II hood (IMC 508.1 & 508.1.1) Response: The existing mechanical units are providing outside air. The outside air will be used as make -up air for the "Type II" exhaust hood fan. (Please refer to general notes and air balance schedule on plan sheet M1.1.) The fan operation of "Type II" exhaust hood fan shall be interlocked with the existing HVAC units, as indicated in the general notes section of the revised drawing M1.1 . Building Comments: June 12, 2009 by Joanna Spencer, Development Engineer (206) 431 - 2440 1. The door opening into the bathroom in front of the sink does not meet accessibility for 60 inch minimum maneuvering clearances at doors. Also doors shall not swing into the clear floor space of any fixture. Please revise the floor plan for the bathroom where the door and • • Bill Rambo, Permit Technician July 8, 2009 City of Tukwila Community Development -3- fixtures shall be placed to meet accessibility clear floor space and maneuvering requirements. (ANSI 404.2.3 & 1004.11.1.1) Response: Interior door to restroom has been reduced to 34" wide, lavatory has been rotated and new exterior wall was pushed out a few inches to accommodate the required space, see sheet A1.1. 2. Sheet A1.1A details 02 & 03 indicated R -30 ceiling insulation and the detail (03) shows R -19 for a wall infill. Revise plan to show R -38 attic insulation and all new exterior walls R -21. (2006 WSEC Table 13 -1 & footnote #3) Response: R38 ceiling insulation has been noted and R21 is noted for the exterior walls on sheet AI.1A. Public Works Comments: June 19, 2009 by Joanna Spencer, Development Engineer (206) 431- 2440 A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA) shall be installed immediately downstream of the existing permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Rock/Box or equal freeze protection enclosure anchored to a minimum 4" concrete pad. Public Works strongly recommends a power supply for the freeze protection enclosure. On your site plan please show the property line(s), street name, North arrow, building location and size of existing permanent water meter and proposed RPPA. Show manufacturer name and backflow model number. Submit RPPA cut sheet and a construction cost estimate for backflow installation. Response: A RPPA has been added to the project reference sheet AU1.1 for more information. We believe that the above responses, together with the enclosed revised plans and technical documents, address all of the comments in The City of Tukwila C \correction letters listed above. Please review and approve the enclosed at your earliest convenience. If you have questions or need additional information, please do not hesitate to contact me at this office at 425- 656 -7430 or ainigues @barghausen.com. Thank you. Sincerely, MAI /LKH/pj [1975c.061.doc] enc: As Noted cc: Brian Wall, Global Alliance Bovis Lend Lease Jay S. Grubb, Barghausen Consulting Engineers, Inc. Daniel B. Goalwin, Barghausen Consulting Engineers, Inc. Caryl Mattson, Barghausen Consulting Engineers, Inc. % 1& 4 $44. Alexia Inigues Project Planner June 15, 2009 Alexia Inigues 18215 72 Ave S Kent, WA 98032 RE: CORRECTION LETTER #1 Mechanical Permit Application Number M09 -066 ARCO AM/PM — 5800 Southcenter Bl Dear Ms. Inigues, City of f 7'il tia S Jim Haggerton, Mayor Department of Community Development Jack Pace, Director This letter is to inform you of corrections that must be addressed before your mechanical permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have question s regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, eqAAStf Bill Rambo Permit Technician encl File: M09 -066 W:\Perrnit Center\Correction Letters \2009\M09 -066 Correction Letter #1.DOC wer /r ?nn Cnnthrontor Rnrrlou,rrl Cnito kiln/) • Tiilruiih Lihchinntnn OR1RR m Ahnnn• 9/)A_A 21.2A7/1 n J ,... 9nA_A21_2!.AC Building Division Review Memo Date: June 10, 2009 Project Name: ARCO AM/PM Permit #: M09 -066 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner' The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 1 lx17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Makeup air shall be required for the new Type II duct. Makeup air shall be supplied during the operation of commercial kitchen exhaust systems that are provided for commercial cooking appliances. The amount of makeup air supplied shall be approximately equal to the amount of exhaust air. The mechanical makeup air and exhaust system shall be electrically interlocked to ensure that makeup air is provided whenever the exhaust system is in operation. The amount of makeup air shall be approximately equal to the amount of exhaust air and not reduce the effectiveness of the exhaust air. The temperature differential between makeup air and the air in the conditioned space shall not exceed 10 degrees. Identify provisions on the plan with relative documentation for a makeup air system that is electronically interlocked with the new Type II hood. (IMC 508.1 & 508.1.1) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M09 -066 DATE: 07 -08 -09 PROJECT NAME: ARCO AM /PM SITE ADDRESS: 5800 SOUTHCENTER BL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: �JG Dl- 1 g Building Division Public Works Fire Prevention DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 *PERMIT COORD COPY � Incomplete n TUES/THURS ROUTING: Please Route Structural Review Required U REVIEWER'S INITIALS: Planning Division Structural ❑ Permit Coordinator ❑ DUE DATE: 07-09-09 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required ❑ DATE: DATE: DUE DATE: 08-06-09 Not Approved (attach comments) C Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M09 -066 DATE: 06 -09 -09 PROJECT NAME: ARCO AM /PM SITE ADDRESS: 5800 SOUTHCENTER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPART A e Sr 1) 'Building Mision Public Works Complete Er Comments: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 •PERMFr COORD COPY PLAN REVIEW/ROUTING SLIP A� NSA t Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required DUE DATE: 06-11-09 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required n DATE: DUE DATE: 07-09-09 Approved n Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator Not Applicable n u Permit Center Use Only CORRECTION LETTER MAILED: t 'S - 0q Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 1/ Date: I ' am ct Project Name: ARCO AM /PM Project Address: 5800 Southcenter Boulevard Contact Person: M Summary of Revision: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Plan Check /Permit Number: M09 -066 ❑ Response to Incomplete Letter # Q Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Alexia Inigues Please see response to comments letter attached dated July 8, 2009. BCE #1975.75 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. try or rt 0 8 2009 istAimir CENT 425 -656 -93. 944 END Phone Number: al ni gues9tharghausen. com Sheet Number(s): Sheet No. M1.1 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: I J� Entered in Permits Plus on f10 � \applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: 1 -2009 1975.036.pdf Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 TRAVELERS CAS it SURETY CO 103408839 03/05/2002 Until Cancelled 4/1 /2001 ARCHIVED $12,000.00 02/14/2002 1 TRAVELERS CAS ft SURETY CO 103408839 03/05/2001 03/05/2002 $6,000.00 03/05/2001 License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status JWPARCL033JA J W PARK CONSTRUCTION LLC CONSTRUCTION CONTRACTOR GENERAL UNUSED 4/1/1997 4/1 /2001 ARCHIVED Untitled Page General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company JOE PARK CONSTRUCTION LLC 5094525122 PO BOX 527 YAKIMA WA 989070527 YAKIMA Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602100482 ACTIVE JOEPACL994DE CONSTRUCTION CONTRACTOR 3/5/2001 3/5/2011 GENERAL UNUSED Other Associated Licenses 1 Business Owner Information Name PARK, JOE Role Effective Date 01/01/1980 Expiration Date Bond Information Insurance Information I I S I I I I • I Page 1 of 2 I https: // fortress .wa.gov /lni/bbip/Detail.aspx 11/02/2009 ARCO BP WEST COAST PRODUCTS, LLC V' k G S64'26'45 "E 104.85' ____ mat \ . \ t \ vk \ \ \0sx \\ O \ \ \\ t►O \ .. \ \ a xt o x► . u \ \ \ q1 \ \ u IT\ NNIo s IN0IN V NOM Vii _ XX \ N Vi ._ 11 1 EXISTING PARKING EXISTING DRIVEWAY ±58' -0" TO NEW ADDITION NEW EXHAUST FAN EXISTING PARKING EXISTING OFFICE EXISTING SALES ROOM EXISTING PARKING EXISTING PLANTER [ :� NEW l � UNISEX e \ RESTROOM HOT FOOD PROGRAM EXPAND SALES AREA INTO EXISTING COVERED PORCH AREA - EXISTING PIC UNIT, COLUMN MTD. EXISTING PIC UNIT, COLUMN MTD. REMODEL INTERIOR OF EXISTING CONVENIENCE STORE REPAINT EXTERIOR REPLACE SIGN A =1' 36' 16" EXISTING SALES ROOM EXISTING CANOPY TO REMAIN. PROVIDE NEW GRAPHICS • EXISTING ADA RAMP R= 5658:65' L= 158.49' SOUTHCENTER BOULEVARD — 26SF ADDITION TO ACCOMMODATE NEW UNISEX ACCESSIBLE RESTROOM EXISTING COOLER RESTRIPE /PAINT EXISTING ACCESSIBLE PARKING STALL (AND PATH) REFER TO AS1.2 EXISTING UNDERGROUND STORAGE TANKS EXISTING DRIVEWAY REPAINT DIRECTIONAL ARROWS, TYPICAL 154TH 144TH ST. STRANDER BLVD. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new p!arl submittal and may include additional plan review fees. SITE DATA ADDRESS: 5800 SOUTHCENTER BLVD. TUKWILA, WASHINGTON OWNER: BP WEST COAST PRODUCTS, LLC 4 CENTERPOINTE LA PALMA, CA LO'r SIZE: 18,593 SQUARE FEET APN: 1157200352 ZONING: RCM (REGIONAL COMMERCIAL MIXED -USE) BUILDING AREA: 1,811.4 SQUARE FEET (EXISTING) 26 SQUARE FEET ADDITION TO STORE 1,500 SF (CANOPY) CC{NSTRUCTION TYPE: II -B NON - SPRINKLERED (STORE); H -B (CANOPY) OCCUPANCY: M (STORE AND GAS) HEIGHT: EXISTING ±18' TENANT IMPROVEMENT TO EXISTING STORE INTERIOR CONSISTING, BUT NOT "LIMITED TO: • DEMOLITION AND REPLACEMENT OF NON LOAD BEARING WALLS :NEW FLOOR FINISHES .LIGHTING IMPROVEMENTS NEW CABINETS & COUNTERTOPS NEW FOOD SERVICE EQUIPMENT NEW GONDOLAS NEW WALL FINISHES AND PAINTING UPDATE EXTERIOR SIGNS .UPDATE EXTERIOR PAINT COLORS 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL FIRE CODE 2006 UNIFORM PLUMBING CODE 2006 NATIONAL ELECTRICAL CODE 2006 INTERNATIONAL MECHANICAL CODE DWG NO. AS1.1 SITE PLAN ARCHITECTURAL A.1.1 CONSTRUCTION FLOOR PLAN A.1.2 FLOOR FINISH PLAN A.1.3 REFLECTED CEILING PLAN A.2.0 EXTERIOR ELEVATIONS C -STORE & CANOPY A.2.3 INTERIOR ELEVATIONS A.2.4 - INTERIOR ELEVATIONS A 25 INTERIOR ELEVATIONS EQUIPMENT Q1.1 EQUIPMENT PLAN Q2.1 EQUIPMENT SCHEDULE ELECTRICAL E1.1 ELECTRICAL ROUGH -IN PLAN ELECTRICAL FLOOR PLAN ELECTRICAL DEMO /LIGHTING PLAN ELECTIRCAL SCHEDULES & DIAGRAMS E1.2 E1.3 E1.4 { PLUMBING P.1.1 PLUMBING DEMOLITION /ROUGH -IN PLANS, NOTES, LEGENDS MECHANICAL M.1.1 MECHANICAL PLAF REIMAGE KNIFES & DETAILS 0 --RAP & DETAILS Plan review approval Is subject to errors and om authorize Approval of construction documents does not authorize the violation of any adopted code or ordinance Receipt of approved Field Copy and conditions is acknowledged` ��. �F gyp, By �� IA o 9 2009 Date: A / Q Q PERMIT CENTER City Of 1Ukwiia BUILDING D VAS gi CLIENT: SHEET NO: 2 ` � F�.�r � NV �r ENG 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION T 05.26.09 PERMIT REVIEW - BP \ 06.05.09 ISSUED FOR PERMIT - CITY /s\ A L A A t2 SEAL: S G, JP 0 W A Sy ,.:.•� 1.„.., p, 28527 . W E i"1 � b I CONFIDENTIALITY STATEMENT: ` THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L&M - FULLERTON SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ 1.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: ALLIANCE Z&DM: CHECKED BY: BP REPM: DRAWN BY: ALLIANCE PM VERSION: PROJECT N0: 1975.75 DRAWING TITLE: SITE PLAN GENERAL PROJECT NOTES A. ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE BUILDING CODES AND LOCAL RESTRICTIONS. CONTRACTORS MUST COMPLY WITH CONTRACTOR REGISTRATION REQUIREMENTS OF ALL GOVERNING AUTHORITIES. THE GENERAL BUILDING PERMITS SHALL BE PAID FOR BY THE OWNER. ALL OTHER PERMITS SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR DIRECTLY RESPONSIBLE. ALL REQUIRED CITY, COUNTY AND/OR STATE LICENSES SHALL BE ACQUIRED AND PAID FOR BY THE INDIVIDUAL SUBCONTRACTOR. B. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT SAME INFORMATION. CONTRACTOR SHALL MAINTAIN ONE COMPLETE SET OF PLANS ON THE PREMISES IN GOOD CONDITION AT ALL TIMES. THIS SHALL INCLUDE ALL ADDENDA AND CHANGE ORDERS. C. DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS, DRAWINGS AND SPECIFICATIONS ARE NOT INTENDED. THE CONTRACTOR IS TO CLARIFY ANY SUCH DISCREPANCIES WITH THE ARCHITECT /CONSULTANT PRIOR TO COMMENCING WORK. D. STATED DIMENSIONS TAKE PRECEDENCE OVER GRAPHICS, DO NOT SCALE DRAWINGS TO DETERMINE LOCATIONS. THE ARCHITECT /CONSULTANT SHALL BE NOTIFIED OF ANY SUCH DISCREPANCIES PRIOR TO CONTINUING WITH WORK. E. GENERAL CONTRACTOR TO REFER TO THESE DOCUMENTS AS WELL AS SPECIFICATIONS FOR IDENTIFICATION OF ALL OWNER SUPPLIED ITEMS, ALL ITEMS NOT MARKED AS 'OWNER SUPPLIED' ARE TO BE SUPPLIED BY GENERAL CONTRACTOR. UNLESS NOTED OTHERWISE, ALL ITEMS ARE TO BE INSTALLED BY GENERAL CONTRACTOR. F. FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S APPROVED SHOP DRAWINGS /DATA SHEETS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. G. THE . CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE JOB IS IN PROGRESS AND UNTIL BUILDING IS OCCUPIED. H. ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN (BROOM) CONDITION AT ALL TIMES. I. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS ! AT ALL TIMES. J. CONTRACTOR SHALL PROVIDE TEMPORARY WATER, POWER AND TOILET FACILITIES AS REQUIRED. K. GENERAL CONTRACTOR IS RESPONSIBLE FOR RECEIVING, UNLOADING, UN— CRATING, INSTALLATION AND HOOKUP OF ALL FOOD SERVICE EQUIPMENT AND OTHER OWNER FURNISHED ITEMS. L. GENERAL CONTRACTOR IS REQUIRED TO LABEL ALL ELECTRICAL PANELS, PLUMBING. VALVES, AND ROOF TOP EQUIPMENT. PLASTIC . PHENOLIC ENGRAVED PLATE SCREWED ON. M. IT IS THE INTENT OF THE ARCHITECT THAT THIS WORK BE IN CONFORMANCE WITH ALL REQUIREMENTS OF THE BUILDING AUTHORITIES HAVING JURISDICTION OVER THIS TYPE OF CONSTRUCTION AND OCCUPANCY. N. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. 0. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION. PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. P. MATERIALS LISTED IN DRAWINGS ARE BASED ON DESIGN INTENT. ALTERNATE SPECIFICATIONS MAY BE ACCEPTED PROVIDED THEY CLOSELY MATCH SPECIFIED MATERIAL. CONTRACTOR IS TO SUBMIT PROPOSED SAMPLES OF SUBSTITUTIONS, ALONG WITH SAMPLE OF THAT SPECIFIED IN DRAWINGS FOR REVIEW BY THE OWNER. Q. GC TO REFER TO BID DOCUMENT PACKET FOR OWNER'S SCOPE OF WORK. SAID DOCUMENT TAKES PRECEDENCE OVER ANY SCOPE THAT MAY BE PRESENTED IN THIS SET OF CONSTRUCTION DOCUMENTS OR SPECIFICATIONS. SITE PLAN R. ALL WORK SHALL BE PERFORMED AS SHOWN ON THESE PLANS AND IN ACCORDANCE WITH "ARCQ'" STANDARD SPECIFICATIONS. S. WHERE LOCAL CODES, ORDINANCES OR REGULATIONS ARE MORE RESTRICTIVE THAN "ARCO'S" STANDARD SPECIFICATIONS, THEIR LOCAL REQUIREMENTS SHALL GOVERN. T. ANY DISCREPANCY BETWEEN FIELD CONDITIONS AND THESE PLANS ARE TO BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER. NO WORK SHALL BE PERFORMED ON THE ITEMS IN QUESTION UNTIL DIRECTED BY THE OWNER. NOTE: BARGHAUSEN HAS NOT PERFORMED AN ADA SURVEY TO VERIFY THE EXISTING SITE AND STORE ACCESSIBILITY. CONTRACTOR TO CONFIRM LOCAL ACCESSIBILITY WITH INSPECTOR AS REQUIRED. CONTACT GLOBAL ALLIANCE PM OR FRANCHISE CONSULTANT TO GET COPY OF LAST SURVEY AND TO CONFIRM ALL NECESSARY UPGRADES FOR CONSENT DECREE HAVE BEEN PERFORM EPARATE PERMIT REQUIRED FOR: ❑ Mechanical 14 Electrical Plumbing as Piping SCALE: 1"= 20' City of Tukwila BUILDING DIVISION CONSUL TA/VTS ARCHITECT /ENGINEER: CONTACTS: PLUMBING /MECHANICAL /ELECTRICAL: CONTACT: Irt BARGHAUSEN CONSULTING ENGINEERS INC. 18205 72ND AVENUE S. KENT, WA 98032 DANIEL B. GOALWIN (425) 656 -7441 CARYL J. MATTSON (425) 656 -1063 SACRAMENTO ENGINEERING CONSULTANTS 10555 OLD PLACERVILLE ROAD SACRAMENTO, CA 95827 CHRIS GILLAND, (916) 368 -4468 c ONF/DEN T /AL /T Y STATEMEIVT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) EXHAUST FAN DETAIL SCALE: 1/4"=1'-0" CURB ASSEMBLIES NO FAN ITEM SIZE 1 # 1 Curb 19.500 "W x 19.500 "L x 22.000 "H Vented UPBLAST EXHAUST FAN MODEL #DU33HFA (95 LBS EACH) BACKROOM II H1 11 II II EXISTING COVERED TRASH ENCLOSURE MIECHANICAL PLAN ampm COFFEE 25 1/2" DIA 12 1/8" DIA 21" SQ. t�lf�I 11F-1 1 H ILJ� 1 EXISTING STORAGE 1 THE TRANSITION BETWEEN THE DUCTWORK AND FAN BASE SHOULD BE EQUAL TO OR GREATER THAN R (DIA) DIMENSION ///i ROOF OPENING DIMENSIONS 18" X 18" 18 18" 18',' amca CERTIFIED RATINGS /. A I R SO AND VENTED CURB ETL LISTED PER UL 705 20 GAUGE ALUMINIZED STEEL CONSTRUCTION 3" CONTINUOUS FLASHING NEW UNISEX REST ROOM EXISTING STORAGE CONTAINER DUL /HFA DIRECT DRIVE CENTRIFUGAL UP -BLAST FAN MODEL HT W B C F R RO WEIGHT LB DU33HFA 24 3/4 25 1/2 1 1/2 21 18 1/2 12 1/8 17 1/2 — OPTIONS: HINGED FAN PITCHED CURB INSULATED CURB UNDERCUT DOOR FEATURES: - ROOF MOUNTED FANS — RESTAURANT MODEL - UL762 - VARIABLE SPEED CONTROL INTERNAL WIRING — WEATHERPROOF DISCONNECT — THERMAL OVERLOAD PROTECTION SINGLE PHASE) - HIGH HEAT OPERATION 300 (149T) EXISTING SALES AREA IIIIICI�( mm III EXHAUST FANS DIMENSIONAL DATA EXHAUST FAN 6" MINIMUM ALL SIDES SECTION THRU HOOD SEE FAN DRAWING FOR DETAILS OFFSET AS REQUIRED COOKING SURFACE SECTION VIEW — MODEL 5424—VH1 CEILING MOUNT 6' -9" ABOVE FLOOR HOOD INFORMATION TABLE i a AIR BALANCE SCHEDULE UNIT TAG SUPPLY AIR RETURN AIR OUTSIDE AIR MAKE -UP ` AIR EXHAUST AIR BLDG PRESS. EC -1 2000 1600 400 400 - 400 PC-2 2000 1600 400 400 - 400 EF -1 - - 650 X50 CEF -1 - - - - 65 -�5 CEF -2 - - - 65 =65 TOTALS 4000 3200 800 S00 1 S(d 20 GENERAL NOTE: CONTRACTOR TO INSPECT EXISTING MECHANICAL UNITS. REPAIR, REPLACE DEFECTIVE PARTS, LEAVE IN LIKE NEW CONDITION. CHECK REFRIGERATION LEVELS AFTER PRESSURE CHECK, RECHARGE IF REQUIRED, CHEMICALLY CLEAN EVAPORATOR AND CONDENSER COILS. INSTALL NEW CONDENSATE DRAIN IF REQUIRED. REBALANCE AIR QUANTITIES TO PROVIDE ADEQUATE OUTSIDE AIR REQUIRED BY CODE AND TO BALANCE THE SPACE TO A MINIMUM OF +200 CFM. 2. INTERLOCK FAN OPERATION OF "TYPE II EXHAUST HOOD" WITH FC -1 AND FC -2 FAN OPERATION. THE OUTSIDE AIR FROM THE EXISTING HVAC UNITS SHALL BE USED AS MAKE —UP AIR FOR THE EXHAUST FANS. KEYED NOTES: 01 NOT USED O CONTRACTOR TO INSTALL CAPTIVAIRE VH1 < 54 "X 36" EXHAUST HOOD ABOVE CONVECTION OVEN (TG7). HOOD TO BE PROVIDED BY GC.. INSTALLED BY ° CONTRACTOR. PROVIDE ALL. 3/8 ALL THREARD ROD AND HANG ACROSS THREE EXISTING JOISTS WITH UNISTRUT. ® 10" SQUARE DUCT FROM TYPE 11 HOOD TO EXHAUST FAN SHALL BE SEALED LIQIUD TIGHT. O4 INSTALL NEW CAPTIVAIRE DU33HFA EXHAUST FAN MOUNTED ON ROOF._ FAN TO BE PROVIDED BY GC. INSTALLED BY CONTRACTOR. FAN IS TO BE A MINIMUM OF 10 FEET FROM ANY OUTSIDE AIR INTAKES, AND A MINIMUM OF 40" FROM PARAPET WALLS. O EXISTING DIFFUSER /GRILLES TO REMAIN. ADJUST DIFFUSERS AS REQUIRED TO FIT WITHIN CEILING GRID. ALL DIFFUSERS AND GRILLES SHALL BE CLEANED AND REPAINTED. ® CONTRACTOR SHALL RELOCATE 12"x12" RETURN GRILLE ABOVE THE FROZEN BEVERAGE DISPENSER. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT DUCTWORK AS REQUIRED. O CONTRACTOR SHALL RELOCATE 12 "x12" BATHROOM EXHAUST FAN TO NEW RESTROOM LOCATION. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT DUCTWORK AS REQUIRED. FAN INFORMATION SCHEDULE Hood Tag Fan Model Mfg. CFM S.P. RPM H.P. Phase Volts 1 EF -1 EXHAUST DU33HFA CAS 650 0.50" 1258 0.33 1 115 AIR REQUIREMENTS HOOD COOKING EXHAUST RISER HOOD N0. MODEL LENGTH EXHAUST SIZE CFM/ TOTAL CONST. QTY. W L RISER S P EXH. CFM 100% V 2 3 ' O " -- 650 0.25" 650 TYPE 5424 DEG. 430 S/S O 0 27" L i4" . j O 0 Hood # 1 S " 18 3 ' C PLAN VIEW HOOD PLAN 3' 0.00" LONG 5424VH1 1 EXPIRES 10 -24 -2010 Date Signed: Jun 30, 2009 REVIEWED FOR CODE COMPLIAN APPROVED JUL 15 2009 City of Tukwila BUILDING DIVISION FACTORY LOCATED & INSTALLED HANGER ANGLES (TYPICAL) .00 "Nom. /3' 0.50 "OD SACRAMENTO ENO /NEER /NO CONSULTANTS 10555 Old Placerville Road Sacramento, CA 95827 -2503 Phone: (916) 368 -4468 Fax: (916)368 -4490 www.saceng.com CLEN14 b ARCO BP WEST COAST PRODUCTS, LLC 0 fir► %' ^. .• U t11 �^ I. l �•� H G ENG`N 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CML ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION 1i\ 6/22/09 CITY PLANCHWK /t\ / 11 SEAL: CONFIDENTIAL IN STATFMFNT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS 15 OWNED BY GLOBAL AWANCE. AND ALSO. THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE. ACCORDINGLY. THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT m DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE 111E MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE. AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL AWANCE EITHER UPON COMPLETION OF 111E INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE. WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: EH AWANCE Z &DM: CHECKED BY: RH BP REPM: DRAWN BY: CSC AWANCE PM: VERSION: PROJECT NO: 1975.75 DRAWING TITLE: MECHANICAL PLAN, SCHEDULES, NOTES, & DETAILS SHEET NO: M Akil. 1r r fr .c. O ihn JL o MAX IF 1 1 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) EXHAUST FAN DETAIL SCALE: 1/4"=1'-0" CURB ASSEMBLIES NO FAN ITEM SIZE 1 # 1 Curb 19.500 "W x 19.500 "L x 22.000 "H Vented UPBLAST EXHAUST FAN MODEL #DU33HFA (95 LBS EACH) BACKROOM II H1 11 II II EXISTING COVERED TRASH ENCLOSURE MIECHANICAL PLAN ampm COFFEE 25 1/2" DIA 12 1/8" DIA 21" SQ. t�lf�I 11F-1 1 H ILJ� 1 EXISTING STORAGE 1 THE TRANSITION BETWEEN THE DUCTWORK AND FAN BASE SHOULD BE EQUAL TO OR GREATER THAN R (DIA) DIMENSION ///i ROOF OPENING DIMENSIONS 18" X 18" 18 18" 18',' amca CERTIFIED RATINGS /. A I R SO AND VENTED CURB ETL LISTED PER UL 705 20 GAUGE ALUMINIZED STEEL CONSTRUCTION 3" CONTINUOUS FLASHING NEW UNISEX REST ROOM EXISTING STORAGE CONTAINER DUL /HFA DIRECT DRIVE CENTRIFUGAL UP -BLAST FAN MODEL HT W B C F R RO WEIGHT LB DU33HFA 24 3/4 25 1/2 1 1/2 21 18 1/2 12 1/8 17 1/2 — OPTIONS: HINGED FAN PITCHED CURB INSULATED CURB UNDERCUT DOOR FEATURES: - ROOF MOUNTED FANS — RESTAURANT MODEL - UL762 - VARIABLE SPEED CONTROL INTERNAL WIRING — WEATHERPROOF DISCONNECT — THERMAL OVERLOAD PROTECTION SINGLE PHASE) - HIGH HEAT OPERATION 300 (149T) EXISTING SALES AREA IIIIICI�( mm III EXHAUST FANS DIMENSIONAL DATA EXHAUST FAN 6" MINIMUM ALL SIDES SECTION THRU HOOD SEE FAN DRAWING FOR DETAILS OFFSET AS REQUIRED COOKING SURFACE SECTION VIEW — MODEL 5424—VH1 CEILING MOUNT 6' -9" ABOVE FLOOR HOOD INFORMATION TABLE i a AIR BALANCE SCHEDULE UNIT TAG SUPPLY AIR RETURN AIR OUTSIDE AIR MAKE -UP ` AIR EXHAUST AIR BLDG PRESS. EC -1 2000 1600 400 400 - 400 PC-2 2000 1600 400 400 - 400 EF -1 - - 650 X50 CEF -1 - - - - 65 -�5 CEF -2 - - - 65 =65 TOTALS 4000 3200 800 S00 1 S(d 20 GENERAL NOTE: CONTRACTOR TO INSPECT EXISTING MECHANICAL UNITS. REPAIR, REPLACE DEFECTIVE PARTS, LEAVE IN LIKE NEW CONDITION. CHECK REFRIGERATION LEVELS AFTER PRESSURE CHECK, RECHARGE IF REQUIRED, CHEMICALLY CLEAN EVAPORATOR AND CONDENSER COILS. INSTALL NEW CONDENSATE DRAIN IF REQUIRED. REBALANCE AIR QUANTITIES TO PROVIDE ADEQUATE OUTSIDE AIR REQUIRED BY CODE AND TO BALANCE THE SPACE TO A MINIMUM OF +200 CFM. 2. INTERLOCK FAN OPERATION OF "TYPE II EXHAUST HOOD" WITH FC -1 AND FC -2 FAN OPERATION. THE OUTSIDE AIR FROM THE EXISTING HVAC UNITS SHALL BE USED AS MAKE —UP AIR FOR THE EXHAUST FANS. KEYED NOTES: 01 NOT USED O CONTRACTOR TO INSTALL CAPTIVAIRE VH1 < 54 "X 36" EXHAUST HOOD ABOVE CONVECTION OVEN (TG7). HOOD TO BE PROVIDED BY GC.. INSTALLED BY ° CONTRACTOR. PROVIDE ALL. 3/8 ALL THREARD ROD AND HANG ACROSS THREE EXISTING JOISTS WITH UNISTRUT. ® 10" SQUARE DUCT FROM TYPE 11 HOOD TO EXHAUST FAN SHALL BE SEALED LIQIUD TIGHT. O4 INSTALL NEW CAPTIVAIRE DU33HFA EXHAUST FAN MOUNTED ON ROOF._ FAN TO BE PROVIDED BY GC. INSTALLED BY CONTRACTOR. FAN IS TO BE A MINIMUM OF 10 FEET FROM ANY OUTSIDE AIR INTAKES, AND A MINIMUM OF 40" FROM PARAPET WALLS. O EXISTING DIFFUSER /GRILLES TO REMAIN. ADJUST DIFFUSERS AS REQUIRED TO FIT WITHIN CEILING GRID. ALL DIFFUSERS AND GRILLES SHALL BE CLEANED AND REPAINTED. ® CONTRACTOR SHALL RELOCATE 12"x12" RETURN GRILLE ABOVE THE FROZEN BEVERAGE DISPENSER. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT DUCTWORK AS REQUIRED. O CONTRACTOR SHALL RELOCATE 12 "x12" BATHROOM EXHAUST FAN TO NEW RESTROOM LOCATION. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT DUCTWORK AS REQUIRED. FAN INFORMATION SCHEDULE Hood Tag Fan Model Mfg. CFM S.P. RPM H.P. Phase Volts 1 EF -1 EXHAUST DU33HFA CAS 650 0.50" 1258 0.33 1 115 AIR REQUIREMENTS HOOD COOKING EXHAUST RISER HOOD N0. MODEL LENGTH EXHAUST SIZE CFM/ TOTAL CONST. QTY. W L RISER S P EXH. CFM 100% V 2 3 ' O " -- 650 0.25" 650 TYPE 5424 DEG. 430 S/S O 0 27" L i4" . j O 0 Hood # 1 S " 18 3 ' C PLAN VIEW HOOD PLAN 3' 0.00" LONG 5424VH1 1 EXPIRES 10 -24 -2010 Date Signed: Jun 30, 2009 REVIEWED FOR CODE COMPLIAN APPROVED JUL 15 2009 City of Tukwila BUILDING DIVISION FACTORY LOCATED & INSTALLED HANGER ANGLES (TYPICAL) .00 "Nom. /3' 0.50 "OD SACRAMENTO ENO /NEER /NO CONSULTANTS 10555 Old Placerville Road Sacramento, CA 95827 -2503 Phone: (916) 368 -4468 Fax: (916)368 -4490 www.saceng.com CLEN14 b ARCO BP WEST COAST PRODUCTS, LLC 0 fir► %' ^. .• U t11 �^ I. l �•� H G ENG`N 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CML ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION 1i\ 6/22/09 CITY PLANCHWK /t\ / 11 SEAL: CONFIDENTIAL IN STATFMFNT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS 15 OWNED BY GLOBAL AWANCE. AND ALSO. THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE. ACCORDINGLY. THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT m DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE 111E MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE. AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL AWANCE EITHER UPON COMPLETION OF 111E INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE. WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: EH AWANCE Z &DM: CHECKED BY: RH BP REPM: DRAWN BY: CSC AWANCE PM: VERSION: PROJECT NO: 1975.75 DRAWING TITLE: MECHANICAL PLAN, SCHEDULES, NOTES, & DETAILS SHEET NO: M MAX IF 1 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) EXHAUST FAN DETAIL SCALE: 1/4"=1'-0" CURB ASSEMBLIES NO FAN ITEM SIZE 1 # 1 Curb 19.500 "W x 19.500 "L x 22.000 "H Vented UPBLAST EXHAUST FAN MODEL #DU33HFA (95 LBS EACH) BACKROOM II H1 11 II II EXISTING COVERED TRASH ENCLOSURE MIECHANICAL PLAN ampm COFFEE 25 1/2" DIA 12 1/8" DIA 21" SQ. t�lf�I 11F-1 1 H ILJ� 1 EXISTING STORAGE 1 THE TRANSITION BETWEEN THE DUCTWORK AND FAN BASE SHOULD BE EQUAL TO OR GREATER THAN R (DIA) DIMENSION ///i ROOF OPENING DIMENSIONS 18" X 18" 18 18" 18',' amca CERTIFIED RATINGS /. A I R SO AND VENTED CURB ETL LISTED PER UL 705 20 GAUGE ALUMINIZED STEEL CONSTRUCTION 3" CONTINUOUS FLASHING NEW UNISEX REST ROOM EXISTING STORAGE CONTAINER DUL /HFA DIRECT DRIVE CENTRIFUGAL UP -BLAST FAN MODEL HT W B C F R RO WEIGHT LB DU33HFA 24 3/4 25 1/2 1 1/2 21 18 1/2 12 1/8 17 1/2 — OPTIONS: HINGED FAN PITCHED CURB INSULATED CURB UNDERCUT DOOR FEATURES: - ROOF MOUNTED FANS — RESTAURANT MODEL - UL762 - VARIABLE SPEED CONTROL INTERNAL WIRING — WEATHERPROOF DISCONNECT — THERMAL OVERLOAD PROTECTION SINGLE PHASE) - HIGH HEAT OPERATION 300 (149T) EXISTING SALES AREA IIIIICI�( mm III EXHAUST FANS DIMENSIONAL DATA EXHAUST FAN 6" MINIMUM ALL SIDES SECTION THRU HOOD SEE FAN DRAWING FOR DETAILS OFFSET AS REQUIRED COOKING SURFACE SECTION VIEW — MODEL 5424—VH1 CEILING MOUNT 6' -9" ABOVE FLOOR HOOD INFORMATION TABLE i a AIR BALANCE SCHEDULE UNIT TAG SUPPLY AIR RETURN AIR OUTSIDE AIR MAKE -UP ` AIR EXHAUST AIR BLDG PRESS. EC -1 2000 1600 400 400 - 400 PC-2 2000 1600 400 400 - 400 EF -1 - - 650 X50 CEF -1 - - - - 65 -�5 CEF -2 - - - 65 =65 TOTALS 4000 3200 800 S00 1 S(d 20 GENERAL NOTE: CONTRACTOR TO INSPECT EXISTING MECHANICAL UNITS. REPAIR, REPLACE DEFECTIVE PARTS, LEAVE IN LIKE NEW CONDITION. CHECK REFRIGERATION LEVELS AFTER PRESSURE CHECK, RECHARGE IF REQUIRED, CHEMICALLY CLEAN EVAPORATOR AND CONDENSER COILS. INSTALL NEW CONDENSATE DRAIN IF REQUIRED. REBALANCE AIR QUANTITIES TO PROVIDE ADEQUATE OUTSIDE AIR REQUIRED BY CODE AND TO BALANCE THE SPACE TO A MINIMUM OF +200 CFM. 2. INTERLOCK FAN OPERATION OF "TYPE II EXHAUST HOOD" WITH FC -1 AND FC -2 FAN OPERATION. THE OUTSIDE AIR FROM THE EXISTING HVAC UNITS SHALL BE USED AS MAKE —UP AIR FOR THE EXHAUST FANS. KEYED NOTES: 01 NOT USED O CONTRACTOR TO INSTALL CAPTIVAIRE VH1 < 54 "X 36" EXHAUST HOOD ABOVE CONVECTION OVEN (TG7). HOOD TO BE PROVIDED BY GC.. INSTALLED BY ° CONTRACTOR. PROVIDE ALL. 3/8 ALL THREARD ROD AND HANG ACROSS THREE EXISTING JOISTS WITH UNISTRUT. ® 10" SQUARE DUCT FROM TYPE 11 HOOD TO EXHAUST FAN SHALL BE SEALED LIQIUD TIGHT. O4 INSTALL NEW CAPTIVAIRE DU33HFA EXHAUST FAN MOUNTED ON ROOF._ FAN TO BE PROVIDED BY GC. INSTALLED BY CONTRACTOR. FAN IS TO BE A MINIMUM OF 10 FEET FROM ANY OUTSIDE AIR INTAKES, AND A MINIMUM OF 40" FROM PARAPET WALLS. O EXISTING DIFFUSER /GRILLES TO REMAIN. ADJUST DIFFUSERS AS REQUIRED TO FIT WITHIN CEILING GRID. ALL DIFFUSERS AND GRILLES SHALL BE CLEANED AND REPAINTED. ® CONTRACTOR SHALL RELOCATE 12"x12" RETURN GRILLE ABOVE THE FROZEN BEVERAGE DISPENSER. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT DUCTWORK AS REQUIRED. O CONTRACTOR SHALL RELOCATE 12 "x12" BATHROOM EXHAUST FAN TO NEW RESTROOM LOCATION. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT DUCTWORK AS REQUIRED. FAN INFORMATION SCHEDULE Hood Tag Fan Model Mfg. CFM S.P. RPM H.P. Phase Volts 1 EF -1 EXHAUST DU33HFA CAS 650 0.50" 1258 0.33 1 115 AIR REQUIREMENTS HOOD COOKING EXHAUST RISER HOOD N0. MODEL LENGTH EXHAUST SIZE CFM/ TOTAL CONST. QTY. W L RISER S P EXH. CFM 100% V 2 3 ' O " -- 650 0.25" 650 TYPE 5424 DEG. 430 S/S O 0 27" L i4" . j O 0 Hood # 1 S " 18 3 ' C PLAN VIEW HOOD PLAN 3' 0.00" LONG 5424VH1 1 EXPIRES 10 -24 -2010 Date Signed: Jun 30, 2009 REVIEWED FOR CODE COMPLIAN APPROVED JUL 15 2009 City of Tukwila BUILDING DIVISION FACTORY LOCATED & INSTALLED HANGER ANGLES (TYPICAL) .00 "Nom. /3' 0.50 "OD SACRAMENTO ENO /NEER /NO CONSULTANTS 10555 Old Placerville Road Sacramento, CA 95827 -2503 Phone: (916) 368 -4468 Fax: (916)368 -4490 www.saceng.com CLEN14 b ARCO BP WEST COAST PRODUCTS, LLC 0 fir► %' ^. .• U t11 �^ I. l �•� H G ENG`N 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CML ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION 1i\ 6/22/09 CITY PLANCHWK /t\ / 11 SEAL: CONFIDENTIAL IN STATFMFNT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS 15 OWNED BY GLOBAL AWANCE. AND ALSO. THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE. ACCORDINGLY. THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT m DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE 111E MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE. AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL AWANCE EITHER UPON COMPLETION OF 111E INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE. WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: EH AWANCE Z &DM: CHECKED BY: RH BP REPM: DRAWN BY: CSC AWANCE PM: VERSION: PROJECT NO: 1975.75 DRAWING TITLE: MECHANICAL PLAN, SCHEDULES, NOTES, & DETAILS SHEET NO: M IF 1 1 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) EXHAUST FAN DETAIL SCALE: 1/4"=1'-0" CURB ASSEMBLIES NO FAN ITEM SIZE 1 # 1 Curb 19.500 "W x 19.500 "L x 22.000 "H Vented UPBLAST EXHAUST FAN MODEL #DU33HFA (95 LBS EACH) BACKROOM II H1 11 II II EXISTING COVERED TRASH ENCLOSURE MIECHANICAL PLAN ampm COFFEE 25 1/2" DIA 12 1/8" DIA 21" SQ. t�lf�I 11F-1 1 H ILJ� 1 EXISTING STORAGE 1 THE TRANSITION BETWEEN THE DUCTWORK AND FAN BASE SHOULD BE EQUAL TO OR GREATER THAN R (DIA) DIMENSION ///i ROOF OPENING DIMENSIONS 18" X 18" 18 18" 18',' amca CERTIFIED RATINGS /. A I R SO AND VENTED CURB ETL LISTED PER UL 705 20 GAUGE ALUMINIZED STEEL CONSTRUCTION 3" CONTINUOUS FLASHING NEW UNISEX REST ROOM EXISTING STORAGE CONTAINER DUL /HFA DIRECT DRIVE CENTRIFUGAL UP -BLAST FAN MODEL HT W B C F R RO WEIGHT LB DU33HFA 24 3/4 25 1/2 1 1/2 21 18 1/2 12 1/8 17 1/2 — OPTIONS: HINGED FAN PITCHED CURB INSULATED CURB UNDERCUT DOOR FEATURES: - ROOF MOUNTED FANS — RESTAURANT MODEL - UL762 - VARIABLE SPEED CONTROL INTERNAL WIRING — WEATHERPROOF DISCONNECT — THERMAL OVERLOAD PROTECTION SINGLE PHASE) - HIGH HEAT OPERATION 300 (149T) EXISTING SALES AREA IIIIICI�( mm III EXHAUST FANS DIMENSIONAL DATA EXHAUST FAN 6" MINIMUM ALL SIDES SECTION THRU HOOD SEE FAN DRAWING FOR DETAILS OFFSET AS REQUIRED COOKING SURFACE SECTION VIEW — MODEL 5424—VH1 CEILING MOUNT 6' -9" ABOVE FLOOR HOOD INFORMATION TABLE i a AIR BALANCE SCHEDULE UNIT TAG SUPPLY AIR RETURN AIR OUTSIDE AIR MAKE -UP ` AIR EXHAUST AIR BLDG PRESS. EC -1 2000 1600 400 400 - 400 PC-2 2000 1600 400 400 - 400 EF -1 - - 650 X50 CEF -1 - - - - 65 -�5 CEF -2 - - - 65 =65 TOTALS 4000 3200 800 S00 1 S(d 20 GENERAL NOTE: CONTRACTOR TO INSPECT EXISTING MECHANICAL UNITS. REPAIR, REPLACE DEFECTIVE PARTS, LEAVE IN LIKE NEW CONDITION. CHECK REFRIGERATION LEVELS AFTER PRESSURE CHECK, RECHARGE IF REQUIRED, CHEMICALLY CLEAN EVAPORATOR AND CONDENSER COILS. INSTALL NEW CONDENSATE DRAIN IF REQUIRED. REBALANCE AIR QUANTITIES TO PROVIDE ADEQUATE OUTSIDE AIR REQUIRED BY CODE AND TO BALANCE THE SPACE TO A MINIMUM OF +200 CFM. 2. INTERLOCK FAN OPERATION OF "TYPE II EXHAUST HOOD" WITH FC -1 AND FC -2 FAN OPERATION. THE OUTSIDE AIR FROM THE EXISTING HVAC UNITS SHALL BE USED AS MAKE —UP AIR FOR THE EXHAUST FANS. KEYED NOTES: 01 NOT USED O CONTRACTOR TO INSTALL CAPTIVAIRE VH1 < 54 "X 36" EXHAUST HOOD ABOVE CONVECTION OVEN (TG7). HOOD TO BE PROVIDED BY GC.. INSTALLED BY ° CONTRACTOR. PROVIDE ALL. 3/8 ALL THREARD ROD AND HANG ACROSS THREE EXISTING JOISTS WITH UNISTRUT. ® 10" SQUARE DUCT FROM TYPE 11 HOOD TO EXHAUST FAN SHALL BE SEALED LIQIUD TIGHT. O4 INSTALL NEW CAPTIVAIRE DU33HFA EXHAUST FAN MOUNTED ON ROOF._ FAN TO BE PROVIDED BY GC. INSTALLED BY CONTRACTOR. FAN IS TO BE A MINIMUM OF 10 FEET FROM ANY OUTSIDE AIR INTAKES, AND A MINIMUM OF 40" FROM PARAPET WALLS. O EXISTING DIFFUSER /GRILLES TO REMAIN. ADJUST DIFFUSERS AS REQUIRED TO FIT WITHIN CEILING GRID. ALL DIFFUSERS AND GRILLES SHALL BE CLEANED AND REPAINTED. ® CONTRACTOR SHALL RELOCATE 12"x12" RETURN GRILLE ABOVE THE FROZEN BEVERAGE DISPENSER. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT DUCTWORK AS REQUIRED. O CONTRACTOR SHALL RELOCATE 12 "x12" BATHROOM EXHAUST FAN TO NEW RESTROOM LOCATION. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT DUCTWORK AS REQUIRED. FAN INFORMATION SCHEDULE Hood Tag Fan Model Mfg. CFM S.P. RPM H.P. Phase Volts 1 EF -1 EXHAUST DU33HFA CAS 650 0.50" 1258 0.33 1 115 AIR REQUIREMENTS HOOD COOKING EXHAUST RISER HOOD N0. MODEL LENGTH EXHAUST SIZE CFM/ TOTAL CONST. QTY. W L RISER S P EXH. CFM 100% V 2 3 ' O " -- 650 0.25" 650 TYPE 5424 DEG. 430 S/S O 0 27" L i4" . j O 0 Hood # 1 S " 18 3 ' C PLAN VIEW HOOD PLAN 3' 0.00" LONG 5424VH1 1 EXPIRES 10 -24 -2010 Date Signed: Jun 30, 2009 REVIEWED FOR CODE COMPLIAN APPROVED JUL 15 2009 City of Tukwila BUILDING DIVISION FACTORY LOCATED & INSTALLED HANGER ANGLES (TYPICAL) .00 "Nom. /3' 0.50 "OD SACRAMENTO ENO /NEER /NO CONSULTANTS 10555 Old Placerville Road Sacramento, CA 95827 -2503 Phone: (916) 368 -4468 Fax: (916)368 -4490 www.saceng.com CLEN14 b ARCO BP WEST COAST PRODUCTS, LLC 0 fir► %' ^. .• U t11 �^ I. l �•� H G ENG`N 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CML ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION 1i\ 6/22/09 CITY PLANCHWK /t\ / 11 SEAL: CONFIDENTIAL IN STATFMFNT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS 15 OWNED BY GLOBAL AWANCE. AND ALSO. THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE. ACCORDINGLY. THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT m DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE 111E MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE. AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL AWANCE EITHER UPON COMPLETION OF 111E INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE. WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: EH AWANCE Z &DM: CHECKED BY: RH BP REPM: DRAWN BY: CSC AWANCE PM: VERSION: PROJECT NO: 1975.75 DRAWING TITLE: MECHANICAL PLAN, SCHEDULES, NOTES, & DETAILS SHEET NO: M