Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M09-070 - HAIR CLUB FOR MEN
HAIR CLUB FOR MEN 545 ANDOVER PK W M09 -070 Parcel No.: 2623049144 Address: Suite No: 545 ANDOVER PK W TUKW CityIlf Tukwila Tenant: Name: HAIR CLUB FOR MEN Address: 545 ANDOVER PK W , TUKWILA WA Contact Person: Name: JEREMY MOELLER Address: PO BOX 82360 , KENMORE WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Owner: Name: SOUTHCENTER CORPORATE SQUAR Address: 150 CALIFORNIA ST , SAN FRANCISCO CA Contractor: Name: C F M HEATING AND COOLING INC Address: PO BOX 82360 , KENMORE WA Contractor License No: CFMHEHC969CD MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: DESCRIPTION OF WORK: INSTALL (1) NEW EXHAUST FAN WITH (3) EXHAUST GRILLES TO CONNECT TO EXISTING BUILDING EXHAUST SYSTEM Value of Mechanical: $1,500.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 EOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 1 0 0 0 * *continued on next page ** M09 - 070 Phone: Phone: 425 - 821 -1293 Phone: 425 - 481 -6239 Expiration Date: 02/04/2010 M09 -070 08/24/2009 02/20/2010 Fees Collected: $196.29 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 08 -24 -2009 Permit Center Authorized Signature: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us taita • Permit Number: M09 -070 Issue Date: 08/24/2009 Permit Expires On: 02/20/2010 Date: (J - d''1 -9 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p rformance of work. I am authorized to sign and obtain this mechanical permit. Signature: 9 L Date: a/ Z'l ^ C9 Print Name: E�{< /"t (P This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -070 Printed: 08 -24 -2009 Parcel No.: 2623049144 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 HAIR CLUB FOR MEN City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 545 ANDOVER PK W TUKW 5: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: M09 -070 ISSUED 06/12/2009 08/24/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. M09 -070 Printed: 08 -24 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10106 V err" i 14 Date: M09 -070 Printed: 08 -24 -2009 Site Address: Tenant Name: Atf CA 010 i i v Men Property Owners Name: P; Anna c Rea, f dta"1., ran e, -� Mailing Address: St cy 3rc( Ave, (4 C 3-GYQ ( M oe,i Mailing Address: P -'b i'OX f; Z3(er J eve.m16 arm. - t uku , (nm CAL CONTRACTOR INFORMATION Name: E -Mail Address: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cLtukwila.wa.us MECHANICAL PERMIT APPLICATION 5 - qc 1"W viou ✓ Park (k) CFAA U QGiiflg cttnd l:aol i!�C n t Cac . t� b. 13D4 tZ3i o �t Contact Person: ,^'U e�Q,bre.,mv ; Fy E -Mail Address: 3 y 6 C-F tri- V u'4C '. (evil Contractor Registration Number: e F M H E Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 301-1 — q u y Suite Number: Co. City Day Telephone: KC() tip Cie City Fax Number: Krnlotxr city Day Telephone: Fax Number: Expiration Date: Floor: New Tenant: ® Yes .. No LAM g811g State Zip CONTACT PERSON - o do w e contact when your; permi r. eady 1/25. 6-2-t- 1243 IN4 9&oz State Zip 405 814- 1c13 W4 950ZQ State Zip 4125 Si[- /243 1- 175 13 (13 0 lot lip ARCHITECT OF RECORD - All p. ns must be we tamped by Architect of Record Company Name: Mailing Address: 2 ZZ( 5 Ave Contact Person: E -Mail Address: Company Name: 'Aar Vito N * A 66 tr ; U fey 5e4- IC City Day Telephone: Fax Number: tkrA . 78(1/ S tate Zip - 4ql — (Nqq ENGINEER OF RECORD - All pla ustbewet mped by Engineer of Record Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1-2009 bh State Zip Page 1 of 2 Unit Types Qty Unit Type: Qty Unit Type: Qty. Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System I Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Valuation of Project (contractor's bid price): /500. (( /+ Scope of Work (please provide detailed information): Try; /A ��) ✓ti ex in 5 4- �n Wr A (3 ex ∎Ai.t4 ottil&S To Cbvin.c - I- °tv ex15P boldin &/5+ewl Use: Residential: New Commercial: New Replacement Replacement Fuel Type: Electric ❑ Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW1YE OR AUTHO �J� AGENT: Signature: C , liL / �� ti" Print Name: 1(..1/' L.{ iii o4Q1, 6r t434o Mailing Address: Date Application Expires: 10 f 2 .... _ 0 9 I Date Application Accepted: to - !�! 4 °r H:\Applications \Forms - Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Date: Ch. /2 'dk, / Day Telephone: -2S 611- 1243 I <e) mew 11 44 9�0� City State Zip Staff Initials: Page 2 of 2 Parcel No.: 2623049144 Address: 545 ANDOVER PK W TUKW Suite No: Applicant: HAIR CLUB FOR MEN Receipt No.: R09 - 00880 Payee: CFM HEATING City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 4147 196.29 Authorization No. ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES RECEIPT Initials: WER Payment Date: 06/12/2009 11:08 AM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000.322.102.00.0 157.03 000/345.830 39.26 Total: $196.29 Permit Number: M09 -070 Status: PENDING Applied Date: 06/12/2009 Issue Date: Payment Amount: $196.29 PAYMENT RECEIVED doc: Receiot -06 Printed: 06 -12 -2009 Project: , ` 1447'r -k'3 Fur Type of Inspection: Po ci G�vl Me`� i Address: �'�S 4 Weil'"" Date Called: / S —� j >3 Special Instructions: V 3 COg 44— ( (fir 1 _ L,,.{ ( bt_ro P Date Wanted: 11 - r (' ydei `a .y p.m. Requester: Phone No: 21910 -9 5(of INSPECTION NO INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: frr Date/ , c(97 El $60.00 REINSPECTIOf+'FEE REQ'[IIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: i June 22, 2009 Jeremy Miller PO Box 82360 Kenmore, WA 98028 RE: CORRECTION LETTER #1 Mechanical Permit Application Number M09 -070 Hair Club for Men — Andover Pk W Dear Mr. Miller, This letter is to inform you of corrections that must be addressed before your mechanical permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, ifer rshall it Technician e File: M09 -070 • City o Tu W:\Pemrit Center \Correction Letters\2009 W09 -070 Correction Letter #1.DOC jem Department of Community Development Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 ® Fax: 206 - 431 -3665 Building Division Review Memo • 41, Date: June 19, 2009 Project Name: Hair Club for Men Permit #: M09 -070 Plan Review: Dave Larson, Senior Plans Examiner Tukwila Building Division Dave Larson, Senior Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) Please provide plans with details as necessary to address the following questions. 1. What will be the size and type of duct material? 2. Where will the exhaust fan be located? 3. Will there be backdraft dampers installed in the new system? 4. Is the existing building system sized adequately to accommodate the additional load? 5. Is the existing building system fan powered with an external mounted fan or fan powered at the individual intakes? 6. Are there backdraft dampers installed in the existing building system to stop backflow from this new system? 7. What will the exhaust system be removing? 8. How far is the existing building exhaust termination from an air intake or opening? Where is it located? Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: M09 -070 PROJECT NAME: HAIR CLUB FOR MEN SITE ADDRESS: 545 ANDOVER PK W Original Plan Submittal Response to Correction Letter # 1 DATE: 08 -17 -09 Response to Incomplete Letter # Revision # After Permit Issued DEPART ENTS: B ilding Division Public Works n Complete Comments: Please Route Documents/routing slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP TUES/THURS ROIE'JTING: APPROVALS OR CORRECTIONS: E M1T Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required n n Y� Planning Division Permit Coordinator DUE DATE: 08 -18 -09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required u REVIEWER'S INITIALS: DATE: DUE DATE: 09-15-09 Approved ❑ Approved with Conditions U Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire El Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M09 -070 PROJECT NAME: HAIR CLUB FOR MEN SITE ADDRESS: 545 ANDOVER PARK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DATE: 06- 12 -09 Revision # After Permit Issued DEPA TMENTS: uildi g [ Public Works Li DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route 4 Structural Review Required n No further Review Required U REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: Documents/routing slip.doc 2-28-02 • PLAN P k E NT A M N /A 6. —I Fire Prevention I V Structural n n REVIEWER'S INITIALS: DATE: Permit Center Use Only ,� j CORRECTION LETTER MAILED: a011-14 0 1 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ ING SLIP Planning Division Permit Coordinator DUE DATE: 06 -16-09 Not Applicable n U DUE DATE: 07 -14 -09 Not Approved (attach comments) k Staff Initials: f i REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 07 -2,3-0/ Plan Check/Permit Number: M09-070 ❑ Response to Incomplete Letter # Response to Correction Letter # 1 ❑ Revision # after Permit is Issued E Revision requested by a City Building Inspector or Plans Examiner Project Name: Hair Club for Men Project Address: 545 Andover Pk W Contact Person: e.m9 Mod Summary of Revision: Heft 15 Lux f e II ;e -b l CCTi G'�JD/1 (?,'tkr'. 1, 2 dewy 6 e k me-fat- 2.. X■�-inj l c ovl m4 3.. "/e5 '1. `{6S l 2H, coo C>Fm 1041 5- Ex-1ern4) roof '1e3 7 8. 75 )o cd-1-ed on roof G ttrseA and 1 w P 54 morn Sheet Number(s): AVG 200 g "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on • City of Tukwila \applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us r" JUL 2 4 2009 COMhI1t1N:T� CV LOP r Phone Number: 2 00 - 5/c f lttu (299 c f J -441 RECEIVED CITY Ol- uKWI mil■ (VNTER Name Bond Bond Effective Expiration Cancel Impaired Bond Received Bond Company Account Date Date Date Date Amount Date 6 Name Number 02/04/200702/04 /2008 $1,000,000.00 02/05/2007 2 DEVELOPERS SURETY it 798903C 02/04/2009 Until Cancelled $12,000.0012/17 /2008 INDEM CO 1 RLI INS CO SRS1008639 02/04/2004 02/04/2009 03/12/2009 $12,000.00 02/04/2004 Name Role Effective Date Expiration Date CLANCY, SHAUN PRESIDENT 02/04/2004 Amount Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 7 CONTINENTAL WESTERN INS CO CNP2739229 02/04/200802/04 /2010 $1,000,000.00 12/16/2008 6 OHIO CAS INS BKW53560669 02/04/200702/04 /2008 $1,000,000.00 02/05/2007 5 OREGON AUTOMOBILE INSURANCE CO1165399 02/04/200602/04 /2007 $1,000,000.0002 /08/2006 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name C F M HEATING AND COOLING INC Phone 4254816239 UBI No. 602361244 Status ACTIVE Address PO BOX 82360 License No. CFMHEHC969CD Suite /Apt. License Type CONSTRUCTION CONTRACTOR City KENMORE Effective Date 2/4/2004 State WA Expiration 2/4/2010 Date Zip 98028 Suspend Date County KING Specialty 1 GENERAL Business Type Corporation Specialty 2 UNUSED Parent Company Business Owner Information Bond Information Insurance Information • • Page 1 of 2 https://fortress.wa.gov/lni/bbip/Detail.aspx 08/24/2009 ACT ACOUSTICAL CEILING TILE LL @TE BY LANDLORD AT TENANTS EXPENSE ADJACENT /ADJUSTABLE LF LINEAL FOOT AFF ABOVE FINISH FLOOR MAX MAXIMUM ALT ALTERNATE MECH MECHANICAL ALUM ALUMINUM MFR MANUFACTURER APPROX APPROXIMATELY MIN MINIMUM @ AT MISC MISCELLANEOUS BFP BLANK FACE PLATE MTD MOUNTED BLDG BUILDING MTL METAL BLKG BLOCKING MW MICROWAVE OVEN CAS BUILDING STANDARD N NORTH, NEW CAB CABINET NIA NOT APPLICABLE CLR CLEAR/CLEARANCE NIC NOT IN CONTRACT CLG CEILING NO NUMBER CL CENTERLINE NOM NOMINAL COL COLUMN NTS NOT TO SCALE COMM COMMUNICATION OC ON CENTER COMP COMPOSITION OPNG OPENING CONST CONSTRUCTION OPP OPPOSITE CONT CONTINUOUS ORIG ORIGINAL CPT CARPET PERM PERMANENT DR CT CERAMIC OR CONCRETE TILE PL If;::::ERELOCATE PD DHER DWG E EXISTING, EAST RB RUBBER BASE EA EACH REF REFRIGERATOR ELEC ELECTRIC REINF REINFORCING ELECL ELECTRICAL REQ'D REQUIRED ELEV ELEVATION (VIEW) REV REVISION /REVERSE ROOM I R RM RO 5 5CHED SC SECT SON SISIR FEET SFICAON GALVANIZED STD STANDARD GD GARBAGE DISPOSAL STL STEEL GL GIASSAGLAZING STOR STORAGE GWB GYPSUM WALL BOARD SUSP SUSPENDED HC HOLLOW CORE TEL TELEPHONE HOW HOL M UNO TYPICAL HM HOLLOW METAL UNO UNLES NOTED OTHERWISE HT HEIGHT VCT VINYL COMPOSITION TILE HVAC HEATING, VENTILATING, VERT VERTICAL W WEST AIR CONDITIONING W! WITH IN INCH W/O WITHOUT INCL INCLUDE WC WALLCOVERING INSUL INSULATION INT INTERIOR WD WOOD JT JOINT WSBF WASHINGTON STATE BARRIER FREE C z 9 T © I ( I I BLDG 1 '/ SCOPE O F WORK . • ADJ SOUTHCENTER CORPORATE S 1 BUILDING 1 TU f \ WILA WASHINGTON , 4 PARTIAL FLOOR TENANT IMPROVEMENT ON THE SECOND FLOOR OF AN EXISTING OFFICE SPACE . THE WORK CONSISTS OF DEMOLITION AND CONSTRUCTION OF PARTITIONS, DOORS AND OTHER FEATURES. THERE IS NO STRUCTURAL, LOBBY CORE, OR SHELL WORK. C ONSTRUCTION TYPE: TYPE V -B • e 3 SPRINKLERS: SPRINKLERED OCCUPANCY: B - OFFICE CORPORA DRIVE NORTH - ANDOVER PARK) AREA OF WORK; 1945 SF S PARCEL ID; 51 -0599163 - 0 � / 6 LEGAL DESCRIPTION : p+ SEPARATE PEIMI i REQUIRED F . ❑GAS Piping P A �il i�/ Of TGkw1Ia , s ®:pi S {ON € ALL THAT CERTAIN REAL PROPERTY SITUATED IN THE CITY OF TUKWILA, COUNTY OF KING STATE OF WASHINGTON, BEING A PORTION OF THE EAST 1/2 OF THE NORTHWEST 114 OF THE SOUTHEAST 1/4 OF SEC. 26, T.23N, R.4E, W.M., AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINING AT THE INTERSECTION OF THE NHERLY LINITEIDN MARGIN TANGENT TO THE PRECEDING COURSE ALONG THE ARC OF A CURVE TO THE RIGHT HAVING A RADIUS OF 50.00 FEET AND A CENTRAL ANGLE OF 90 °6'49 ", AN ARC LENGTH OF 78.64 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 501.40 SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 1i4( THENCE ALONG SAID PARALLEL LINE N88 °05'42 "W 180.90 FEET TO A POINT ON A LINE THAT IS PARALLEL WITH AND 261.00 FEET WESTERLY OF THE EAST LINE IF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE N 01 °4T29 "E 136.00 FEET 0 AND 365.40 FEET SOUTHERLY OF THE T A S THERLY H NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG LAST SAID PARALLEL LINE S88 "05'42 "E 37.50 FEET ALONG LAST SAID PARALLEL LINE N88 0542W 12.50 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 0 0 ,EXIT .., //J A - MI N KLE R BLVD. NORTH ' / ' 1 NTS I SITE PLAN S © o / r --- REVISIONS p r O changes Sh t) ma Ci0 the scope of Work W Itf1 O pEj a r p Ut oval of Tukwila Bull g DIVISIOn, Revisions wlll require a new p an submlttai ma I y nclude addit plan review _a -� .....� � -� fee s. • n it n ®, 11 V `/ 7 0 Plan review approval IS subject t d O pyl oral of construction documents not authorize I €' ( ne violation of any adopted de or ordinance. Re ..)(1 approved Field Copy and conditions is acknowledged: Q G7 ' r'T 1405 ► / � < y ¢ ce ¢ a STRAN ER BLVD. INT BUILDING CODE, 2006 EDITION, AS ADOPTED BY THE STATE OF WASHINGTON. INTERNATIONAL FIRE CODE, 2006 EDITION, AS ADOPTED BY THE STATE OF WASHINGTON. INTERNATIONAL MECHANICAL CODE, AS ADOPTED BY THE STATE OF WASHINGTON. INTERNATIONAL PLUMBING CODE 2006 ICC A117.1, 2003 EDITION. WASHING STATE VENTILATION AND INDOOR AIR CODE (WSVIAQ) ( ) , PROJECT DIRECTORY ° 0 _ EXIT } d o z ¢ IDT�: OCCUPANT LOAD: AREAS OF WR WORK ¢ w w v = - MINK R E SITE LVD. 945 SF 100 = 9 OCCUPANTS © 1: 1 EXIT REQUIRED 1 EXIT PROVIDED , 00 C > NORTH UPLAND DR• cn MIDL AND 1. TRILAND D BUILDING OWNER: PROPERTY MANAGER: MERIWETHER PARTNERS LLC PINNACLE REALTY MANAGEMENT CO, 2ND & SENECA BUILDING 810 3RD AVE. 1191 2ND AVE. SUITE 140 SUITE 1570 SEATTLEWA (2 6) 903 -06 2 (P} 98104 (206) 816-1570 (P) (206) 903 -0668 (FAX) (206) 381 1200 (FAX) CONTACT: TAMARA GENZALE CONTACT: JOEL P. ASLANIAN EMAIL: tgenzale @prmc.com EMAIL: jaslanian @mericap.com SPACE PLANNER: TENANT: NORTH 2 I ABBREVIATIONS 3 I KEY PLAN & OCCUPANT LOAD CALCULATION 1/16 " =1'-0" 4 I VICINITY MAP NTS (2) 1/8" NOTES: METAL STUDS STAGGERED 8' BRACING PER 91TI 1. MARVIN STEIN AND ASSOCIATES, LLC HAIR CLUB FOR MEN 2221 5TH AVE. 1515 S. FEDERAL WAY SEATTLE, WASHINGTON 98121 SUITE 401 CONTACT: LISA BOLSTER BOCA RATAN, FL 33432 TEL: (206) 441 -1449 CONTACT: JANE DAVIS -EMBER FAX: (206 ) 441.4361 EMAIL: Lbolster @marvinsteln,com @ -0° ac, FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12' -0° ATTACH TO STRUCTURE ABOVE W/ HILTI POWER DRIVEN FASTENER I 1 S 314° MIN. PROVIDE AT DEMISING AND SOUND PARTITIONS 4' -0" WIDE ACOUSTICAL CEILING TILES CENTERED OVER PARTITION ABOVE HUNG CEILING. Date: 6e-2W �ZN SEISMIC Qt il BUILDING N #10 SCREWS CONTINUOUS CEILING GRID - DO NOT CUT. . 114" NON -COMB, WD FILLER i /� \ UNDER MAIN RUNNERS 5 I PROJECT INFORMATION /DIRECTORY CONTINUOUS CEILING GRID - ttttt tttttttttt ,_�I«,e DO NOT CUT. _ SligISI f,},t��,<s,« llistoarA �FitwAstat pica REVEAL (PAINT BLACK) OR ' K+11■11 L CONTRACTOR SHALL PROVIDE ALL WORK AND MATERIALS IN ACCORDANCE WITH APPLICABLE CITY, COUNTY, STATE AND FEDERAL BUILDING AND FIRE CODES. 2. CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN THE CONTRACT DRAWINGS & SPECIFICATIONS. 3 CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 4, B/S INDICATES "BUILDING STANDARD' AS PROVIDED BY LANDLORD AS DRAWN AND /OR SPECIFIED IN BUILDING CONTRACT DOCUMENTS. IF NOT SPECIFIED, CONTRACTOR SHALL SEE ADJACENT SPACES FOR EXISTING EXAMPLES AND CONDITIONS. 5, WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED FOR SEISMIC CONDITIONS. 6. ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE ALARM, SPRINKLER AND SECURITY DESIGN SHALL BE PERFORMED BY THE CONTRACTOR. 7, ALL FURNITURE DESIGN SHOWN ON PLANS IS SCHEMATIC ONLY AND NOT IN CONTRACT, UNO. TENANT'S FURNITURE VENDOR SHALL FIELD VERIFY PREMISE FOR LAYOUT CONFIGURATION AND CLEARANCES. 8. ALL VOICE/DATA AND CABLING DESIGN SHOWN ON PLANS IS SCHEMATIC ONLY AND NOT IN CONTRACT, UNO. TENANT'S CABLING VENDOR SHALL VERIFY TENANTS REQUIREMENTS AND FIELD CONDITIONS. THE CONTRACTOR SHALL PROVIDE ROUGH -IN AS NOTED, COORDINATION AND SCHEDULING FOR THIS PORTION OF THE WORK. 9. THE FOLLOWING DRAWINGS ARE BASED ON ELECTRONIC INFORMATION DERIVED FROM A NUMBER OF SOURCES. WHILE DEEMED RELIABLE, MS &A CANNOT BE HELD RESPONSIBLE FOR INFORMATION FROM OTHERS NOT FIELD VERIFIED OR WHICH HAS BEEN ALTERED BY OTHERS. 10. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING MANAGEMENT ON CONSTRUCTION HOURS, PROCEDURES AND METHODS ALLOWABLE IN THIS BUILDING. 11. PROVIDE MS &A WITH THREE (3) SETS OF REPRODUCIBLE PRINTS FOR ALL CASEWORK SHOP DRAWINGS FOR REVIEW & APPROVAL 12. PROVIDE MS &A WITH THREE (3) SETS OF REPRODUCIBLE PRINTS FOR ALL DOOR HARDWARE , APPLIANCES AND EQUIPMENT SUBMITTALS FOR REVIEW & APPROVAL 13. PROVIDE MS &A WITH THREE (3) SETS OF FINISH SAMPLES FOR ALL NEW SCHEDULED FINISHES, INCLUDING PAINT, FOR REVIEW & APPROVAL. 14, UPDATE AND DISTRIBUTE A PERIODIC SUBMITTAL LOG 15, CONTRACTOR TO FIELD VERIFY ALL ELEMENTS INDICATED AS EXISTING ON PLANS. 16. DOORS & HARDWARE SHALL BE REUSED, RELOCATED OR NEW BASED ON AVAILABLITY AND SUITABLITY, 17. ALL HARDWARE SHALL BE TENANT STANDARD FINISH, U.N.O. MATCH EXISTING CONDITIONS, Marvin Ste 4 ".sociates, LLC planning � design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 SUSPENDED CEILING. - �+ � � , ....--d I �,I ` � LINE OF CEILING GRID BEYOND, SEE R,C.P. CONT. l' METAL TRIM W/ PAPER WING REVEAL (PAINT BLACK) ORMATCH MATCH EXISTING, BLACK FOAM TAPE HOLD BACK 1/4" FROM EDGE OF TRACK. 31/2" X 25 GA. STL, STUDS 24" EXISTING CONDITION. @ O.C. W/ 518" GWB, TYPE 'X', EACH SIDE. 1 /8" BLACK FOAM TAPE HOLD BACK i s. C 1 C'"� -^- I :.. o 1/4" FROM EDGE OF TRACK CONT. 3 1/2" x 1 114° 25 GA, TRACK WI (2) #10 SCREWS @ 24" O.C. s, �---�� I 6" X 18 GA. METAL PLATE BLOCKING @ WALL HUNG ITEMS HEAD SECTION 6 NA ) THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF V.A.V. BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY MS &A PRIOR TO ANY INSTALLATION. THIS IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED, ALL ASPECTS OF THE DESIGN & CONSTRUCTION OF THE HVAC SHALL BE PERFORMED BY THE CONTRACTOR. RE- CIRCUIT SWITCHING OF EXISTING LIGHTING AS NECESSARY TO COMPLY WITH NEW LIGHTING LAYOUT CONTRACTOR SHALL LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE TO CURRENT CODES AS NECESSARY. RE -USE EXIT SIGNS AS POSSIBLE. REPAIR OR REPLACE ALL DAMAGED CEILING TILE AND GRID AS NECESSARY TO MATCH EXISTING ADJACENT UNO, PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT THE CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, FIRE SPRINKLERS, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS, THE CONTRACTOR IS TO NOTIFY MS&A OF THE CONFLICT(S) SO A NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED. THE CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTING PER CODE. THE CONTRACTOR SHALL PROVIDE AUDIBLE AND VISUAL ALARMS PER CODE. ALL LIGHTING AND CONTROLS SHALL BE B/S, UNO. THE CONTRACTOR SHALL SATISFY THE LIGHTING SPECIFICATIONS BASED ON THE AVAILABLE ELECTRICAL VOLTAGE. CONTRACTOR SHALL COMPLY WITH ALL AUTOMATED SHUT -OFF CONTROLS, SWITCHING, SENSORED SWITCHES, TIMED SWITCHES, AND TESTING AND COMMISSIONING REQUIREMENTS. DOCUMENTS SHOW SCHEMATIC SWITCH LOCATION ONLY. ALL B/S EXIT LIGHTS SHALL BE "LED" STYLE AND LESS THAN 5 WATTS /FIXTURE, UNO, DRAWN BY JJ JOB NO 99135.170 1 PROVIDE ACOUSTIC BATT I� CHECKED BY: LB DATE: 05/07/09 �,�"'..� (: '.4 .--..+ 3112" x 25 GA. GALV. STEEL STUD 0 F 24" 0.C. WITH 518" TYPE 'X' GWB EACH SIDE. PLAN VIEW LATERAL BRACING TENANT WALLS (NO CASEWORK) INSULATION BETWEEN STUDS AT SOUND AND DEMISING PARTITIONS ONLY. SCALE: AS NOTED NTS REVISIONSASSUANCE: 8' MAX 8' MAX 8' MAX 8' MAX a MAX s MAX 2'Mnx �. �, �, �.� ` NO REVISIONS INDICATED THUS a DATE ` LATERAL i' 1.1 5/8" GWB, TYPE EACH SIDE, TYP, BRACING PER DETAIL ABOVE (TYP.) BASE, AS SCHEDULED. CANT. 25 GA. GALV. STEEL RUNNER CHANNEL ANCHOR TO FLOOR AS 1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FT. LONG. 2. TEMPORARY ATTACHMENT OF PARTITION TOP TRACK TO THE GRID IS PERMITTED TO ALIGN AND SET THE WALL UNTIL PERMANENT BRACING IS PROVIDED. REMOVAL OF THE TEMPORARY HOLDING SCREWS IS UP TO THE DISCRETION OF THE SPECIFIC LOCAL BUILDING OFFICIAL. CONTRACTOR TO VERIFY. 3, PROVIDE BRACING AT ANY PERMANENT PARTITION THAT IS NOT ATTACHED TO CEILING GRID, -_.,.. + r ' v!• , I - REQ'D. HILTI POWER DRIVEN FASTENER 3/4" MIN. EMBEDMENT. BASE SECTION 7 1 NA 8 I PARTITION HEAD BRACING DETAIL 1.1/2 " =1'-0" 9 IBIS TENANT PARTITI 112 " =1' -0" 10 I LIGHTING NOTES 11 GENERAL NOTES I DOOR NUMBER I® B/S WALL MOUNTED CABLE OUTLET rntafmma EXISTING B/S CORRIDOR PARTITION nEr R aft OF TUKWILA y ( Il 2 act TI -1 COVER SHEET AND DETAILS PERMIT TI-2 DEMOLITION PLAN ° ` TI -3 CONSTRUCTION PLAN TI-4 REFLECTED CEILING PLAN TENANT: HAIR CLUB FOR MEN illiter 0 7 0 U TYPE OF DOOR EXISTING B/S CEILING GRID AND TILE TO REMAIN A. B/S 3' -0" WIDE SOLID CORE WOOD DOOR IN BIS FRAME, TO MATCH EXISTING I I EXISTING B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN B. NOT USED C. 3'-0° WIDE SOLID CORE WOOD POCKET DOOR IN WOOD FRAME, TO MATCH EXISTING, W/ NEW OR RELOCATED B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE O B/S COREDRILL 3e NEW B/S CORRIDOR PARTITION TO MATCH EXISTING BIS PARTITION REMAIN METAL TRACK &ASSEMBLY I I EXISTING 2' -0" x 4' -0 RECESSED FLUORESCENT LIGHT FIXTURE TO BE REMOVED/RELOCATED -�- -, B/S EXIT SIGN (DIRECTIONAL WHERE SHOWN) N O NEW EXHAUST FAN Q EXISTING RECESSED FLUORESCENT WALL WASH LIGHT FIXTURE TO REMAIN O EXISTING RECESSED FLUORESCENT DOWNLIGHT FIXTURE TO REMAIN �� �� BIS RECESSED FLUORESCENT DOWNLIGHT OR WALL WASHER FIXTURE TO BE REMOVED/RELOCATED B/S LIGHT TO BE UPGRADED FOR EMERGENCY LIGHTING. EMERGENCY LIGHT IS CONCEPTUAL ONLY ELECTRICAL CONTRACTOR TO PROVIDE DESIGN. ." NEW MIDMARK 355 LIGHTING SYSTEM IPr B/S SWITCH (3=3 WAY) (X= CIRCUIT) N' NEW 'R' RELOCATED let B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET � B/S WALL MOUNTED FOURPLEX ELECTRICAL OUTLET EXISTING TENANT INTERIOR TO - _ -_ _ EXISTING CONSTRUCTION TO BE DEMOLISHED BIS TENANT PARTITION: EACH 6" UNLESS HARDWARE OTHERWISE a. B/S LATCHSET NOTED b, B/S LOCKSET c. B/S PRIVACY LOCK d, B/S LOCKSET & CLOSER e. FLUSH MOUNT FINGER PULL AND LOCKSET. NOTES: BIS WALL MOUNTED DEDICATED FOURPLEX ELECTRICAL OUTLET koR WALL MOUNTED NEMA 5.20R DUPLEX ELECTRICAL OUTLET @ 16" AFF. NEW INTERIOR 3 1/2" METAL STUDS WITH 5 /8" GWB SIDE FROM FLOOR TO UNDERSIDE OF HUNG CEILING, SEE DETAIL 91TI -1. TI -5 ELECTRICAL/ COMMUNICATIONS PLAN TI -6 FINISH PLAN TI -7 ENLARGED PLANS, SECTIONS AND ELEVA ONS REVIEWED COMPLIANCE OVE A o "" " it BUILDING DIVISION Id NEW MALE INLET, HUBBELL WIRING DEVICE - KELLEMS #HBL5278c (OR EQUIVALENT) FLANGED NYLON RECEPTACLE, STRAIGHT BLADE, CURRENT RATING 15 AMPS, VOLTAGE RATING 125 VOLTS, POWER RATING .5 HP. NEMA 5 -15R, 2 POLES, 3 WIRES. B/S WALL MOUNTED COMBINATION VOICE/DATA OUTLET ® EXISTING B/S TENANT DEMISING PARTITION. _ = B/S RECITE PARTITION: FULL HT, IN B/S WOOD FRAME WITH SAFETY GLASS WHERE REQUIRED - BUTT JOINT, TYPICAL. �� /�� NEW CASEWORK ai l °iiiii SHEET TITLE: SECOND FLOOR COVER S H E ET AN D DETAILS 1. THRESHOLDS AT DOORWAYS SHALL BE 1/4" MAXIMUM IN HEIGHT. 2. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO MATCH B/S. ALL HARDWARE TO BE LEVER -TYPE, HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48' MAX. ABOVE THE FLOOR. 3. THE MAXIMUM FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER FIRE DOORS SHALL BE AS FOLLOWS; INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR = 5.0 POUNDS (222 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. PROVIDE WALL STOPS (FLOOR STOPS WHERE REQUIRED) AT ALL INTERIOR DOORS. 'N' NEW 'U' UPGRADE EXISTING NOTE ALL OUTLETS TO BE MOUNTED 15" A.F.F. - TO BOTTOM OF OUTLET PER W.S.B.F. REQUIREMENTS U.N.O. ALL DATA & COMMUNICATION LINES TO BE ROUGH -IN ONLY (MUD RING W/ PULL WIRE) REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW COPYRIGHT T I - 1 1 121 DOOR LEGEND 131 ELEC.' /COMMUNICATIONS LEGEND 141 CONSTRUCTION LEGENDS NTS 151 LIGHTING LEGEND NTS 161 DRAWING INDEX BY MS &A 2009. OF I■t01111111111■Il IliI� ® II■ r ©� I■ o iIl IZigILr1• ,mom fir' ■ n`►�1i_ 1111 ■i ORI w^ 1'111111111=Rfas ■1 ■=u■ 111 111111111111111•111111 202 =IN 10.11111M1111 11 ■II ? "ll rl1111111■I1 ■:_•;7 " 11111mli// ��� ;I &!!!!!411111111111117 !1■ ■ = III � 1 MI IBM M MI % `I,>•10/11COM ©. MI = MI 0 ■® M 1111111111M ��� ■� ■■ �� 1 201 I CEILING NOTES: 1. SEE DETAILS ON COVER SHEET FOR SEISMIC AND CEILING SUPPORT INFORMATION. 2. CONTRACTOR IS TO VERIFY THAT ALL FLUORESCENT LIGHT FIXTURES ARE EQUIPED WITH PARABOLIC LENSES AND UPGRADE AS NECESSARY TO MATCH. 3. REMOVE EXISTING LAMPS FROM ALL 20(4' LIGHT FIXTURES AND INSTALL ALL NEW TENANT PROVIDED LAMPS: DURO -TEST, VITA LITE, FLUORESCENT @ 32 WATTS PER LAMP. REFLECTED CEILING KEYNOTES: O NEW MIDMARK 355 LIGHTING SYSTEM TO BE FURNISHED BY TENANT AND INSTALLED BY CONTRACTOR. COORDINATE LOCATION WITH TENANT. SEE TI-5 FOR ELECTRICAL SPECIFICATIONS O CONTRACTOR IS TO PROVIDE & INSTALL NEW MANUAL SWITCH CONTROLLED EXHAUST FAN TO TIE INTO THE BUILDING EXHAUST SYSTEM AND VENT TO THE OUTSIDE OF BUILDING, FAN IS TO RUN AT 400 -600 CMF. 0 CONTRACTOR TO INSTALL TENANT PROVIDED VANITY LIGHT, LIGHTING CALCULATION TOTAL FIXTURES 1 3 5 0 3 1 I TOTAL 12 WATTAGE 288 480 78 26 872 AREA OF SPACE IS 945 SF 945 X 1= 945 WATTS ALLOWED TOTAL WATTS PROPOSED WATTS IS UNDER WATTAGE ALLOWED REFLECTED CEILING PLAN 1/8" =1' -0" 0 5' 10' riertanimmli NORTH 20' 30' 1 REVIEWED FOR CODE COMPLIANCE AUG 2 0 2009 City of Tukwila BUILDING DIVIRVINI GORRE q TIQN LTR# M oq -ono RECEIVED AUG 1. 7 2009 PERMIT CENTER SOUTHCENTER CORPORATE SQUARE BUILDING 1 TUKWILA, WASHINGTON Marvin Ste' : ►sociates, LLc planning design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: JJ JOB NO.: 99135.170 CHECKED BY: LB DATE: 05/07/09 SCALE: AS NOTED REVISIONS/ISSUANCE: NO. REVISIONS INDICATED THUS A REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2009. DATE TENANT: HAIR CLUB FOR MEN SHEET TITLE: SECOND FLOOR REFLECTED CEILING PLAN TI -4 OF f E N MT R J / (E METER (E)2 "NG (E)AL -1000 GAS METER (LOW PRESSURE) ARRANGE AND PAY FOR PSE TO CHANGE METER AND PRV AS REQUIRED TO SWITCH FROM LOW PRESSURE TO 2 –PSI SERVICE. 600 (E)TRANE YC06000 800MBH HEATING c0 z N / — INSTALL PSE AND AGA APPROVED PRV. 2 –PSI TO AHU SERVICE PRESSURE (APPROX. 11 "WG), TYPICAL EACH AHU. INSTALL NG PIPING ON FOAM BLOCKS 2 "NG Roof Mechanical Plan SCALE: 1/8" = 1' -0" VENT 3 "VTR 41 NORTH EF-2 REMOVE THE EXISTING EXHAUST FAN INSTALL EF -3 IN THE SAME LOCATION. PROVIDE CUTTING AND PATCHING AS REQUIRED. (E)DRYER EXHAUST — (E)2 "VTR RELOCATE EXISTING ROOF HOOD TO PROVIDE 3'– CLEARANCE TO UNIT AND 10'– CLEARANCE TO OUTSIDE AIR INTAKE, JOE TO VERIFY VENT REMAINS FUNCTIONAL OR HAS BEEN ABANDONED IN PLACE. SEE EE SOUTHCENTER CORPORATE SQUARE BUILDING 1 TUKWILA, WASHINGTON EXPIRES: 9/08/2006 PRICING SET THE OREENBUSCH GROUP, INC ))) Itr MOT 2111 111% aoe 2711-05e0 371-0041 Mt Marvin Ste sociates, LLC planning 5 design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 - 1449 DRAWN BY: MM /AA JOB NO.: 07111 -000 CHECKED BY: JWG DATE: 06/04/08 SCALE: AS NOTED REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS A PRICING SET REVISION PRICING SET REVISION REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. DATE 03/28/08 06/04/08 TENANT: HAIR CLUB FOR MEN SHEET TITLE: ROOF MECHANICAL PLAN M4.0 OF 7 i MO9o7O REVIEWED FOR A C .�.,. DE COMPLIANCE AUG 2 0 2009 City of Tukwila BUILDING DIVISION RECEIVED AUG 17 2009 PERMIT CENTER