Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M09-077 - GATEWAY - BUILDING 7
GATEWAY BLDG 7 12720 GATEWAY DR M09 -077 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Value of Mechanical: $68,700.00 Type of Fire Protection: doc: IMC - 10/06 2716000070 12720 GATEWAY DR TUKW Citf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila. GATEWAY BLDG 7 12720 GATEWAY DR , TUKWILA WA RREEF AMERICA REIT II CORP/ PO BOX 4900 #207 , SCOTTSDALE AZ CHRIS LEE 7717 DETROIT AV SW , SEATTLE WA MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU MECHANICAL PERMIT DESCRIPTION OF WORK: REPLACE (1) PACKAGED ROOFTOP UNIT (RENEWAL OF EXPIRED PERMIT M07 -243). Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial Fees Collected: $954.56 International Mechanical Code Edition: 2006 EOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 1 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 768 -4266 Phone: 206- 768 -4180 Expiration Date: 12/31/2010 M09 -077 06/25/2009 12/22/2009 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M09 -077 Printed: 06 -25 -2009 Permit Center Authorized Signature: Print Name: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Permit Number: M09 -077 Issue Date: 06/25/2009 Permit Expires On: 12/22/2009 Date: ( - 0 1 S — ()1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction - • e performance of work. I am authorized to sign and obtain this mechanical permit. S Signature: "' .�� —� Date: Z 'b This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -077 Printed: 06 -25 -2009 Parcel No.: 2716000070 Address: Suite No: Tenant: GATEWAY BLDG 7 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 8: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12720 GATEWAY DR TUKW 4: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M09 -077 ISSUED 06/17/2009 06/25/2009 2: No changes, shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 11: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 12: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 13: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) M09 -077 Printed: 06 -25 -2009 S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M09 -077 Printed: 06 -25 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Date: Print Name: AP ✓LC I l� S doc: Cond -10/06 M09 -077 ordinances governing or local laws regulating Printed: 06 -25 -2009 Tenant Name: Name: CHRIS LEE CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us King Co Assessor's Tax No.: 2716000070 Site Address: 12720 GATEWAY DR TUKWILA, WA Suite Number: New Tenant: GATEWAY BLDG 7 Property Owners Name: RREEF AMERICA REIT II CORP Mailing Address: PO BOX 4900 #270 CONTACT PERSON Who do we contac when your permit is ready to be issued Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City E -Mail Address: Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW City Contact Person: S FLINK Day Telephone: E -Mail Address: STEVE.FLINK@MACMILLER.COM Fax Number: Contractor Registration Number: MACDOFS980RU Expiration Date: Contact Person: E -Mail Address: Company Name: CHRIS LEE Mailing Address: 7717 DETROIT AVE SW MECHANICAL PERMIT APPLICATION Mechanical Permit No. Project No. (Foi Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Contact Person: CHRIS LEE E -Mail Address: CHRIS.LEE@MACMILLER.COM H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 hh SCOTTSDALE City Floor: ❑ Yes AZ State Day Telephone: (206) 768 -4266 State (LO of ©t.A.1/ ..No Zip Zip Fax Number: MECHANICAL CONTRACTOR INFORMATION SEATTLE ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: N/A Mailing Address: cit Day Telephone: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record SEATTLE City WA 98106 State (253) 680 -3172 (253) 680 -3173 12/31/2009 State Zip Zip WA 98106 State Day Telephone: (206) 768 -4266 Fax Number: Zip Page 1 of 2 Unit Type: � ' _ _ Qty : � • Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Comm/Ind • Valuation of Project (contractor's bid price): $ 68,700 Scope of Work (please provide detailed information): REPLACE (1) PACKAGED ROO OP UNIT Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ® Gas ❑ Other: Indicate type of mechanical work being installed and the quant'ty below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature: BUILDING WNER OR AU • i ED AG . Print Name: DARLA DOLL Day Telephone: (206) 768 -4278 Mailing Address: 7717 DETROIT AVE SW Date Application Accepted: uuLo-10P1 H :\Applications\Forms- Applications On Line\2009 Applications NI-2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh SEATTLE City Date: 06/16/2009 WA 98106 State Zip Date Application Expires: 0[11-1 4 1 Staff Initials: Copy Reprinted on 06 -17 -2009 at 13:03:16 06/17/2009 RECEIPT NO: R09 -00908 Initials: JEM User ID: 1165 Total Payment: 986.37 Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. SET ID: S000001250 SET NAME: MACDONALD MILLER SET TRANSACTIONS: Set Member M09 -076 M09 -077 TOTAL: TRANSACTION LIST: Type Method Description Amount Payment Check 2158 986.37 TOTAL: 986.37 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES Cif, of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us Amount 604.55 381.82 604.55 SET RECEIPT • Payment Date: 06/17/2009 Account Code Current Pmts 000.322.102.00.0 986.37 TOTAL: 986 . 3 7 PAYMENT RECEIVED Project: �,,If -bzw... — 7 Type of In_s ection: / \ /rr A. 49 ress: Date Called: Special Instructions: N Date me J ' U Requ Phone No: 41oS -ate-, INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 ?0 NIA.A proved per applicable codes. ❑ Corrections required prior to approval. . COMMENTS: .2. "* ( 41P --71 .1, 4 ' ../e: /17/1," 4 $60.00 EINSPECTION F REQUIRE . Prior to inspection, fee must be paid, 6300 Southcenter lvd., Suite 100. Call to schedule reinspection. Receipt D d Date: COMMENTS: Type of Inspection: l /?,f 9/ — . , v j /A/ Address: /272o 'etc, L• Date Called: Special Instructions: Date Wanted: 7 -- .2. /_ , cy P/C b G -4S Pi -'i ift,'‘ / 'i Phone No: 966 --356 —.0 6'3 9 ' PaleNvi, N '7-lt 47 Sl,t /OY.Q •e" ) , V J A z., Id ;i 2pic a /') `. -r' N4 / ,tl c(rc/ A,,,/,',,_ ,:77 / Project: /-� �/e/� 7 Type of Inspection: h , ,Y/ /v Address: /272o 'etc, L• Date Called: Special Instructions: Date Wanted: 7 -- .2. /_ a (..)9 p.m. Requester: Phone No: 966 --356 —.0 6'3 L INSPECTION RECORD Retain a copy with permit /17651.D77 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION kV- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 V Inspector: D /"R » d5 Approved per applicable codes. Corrections required prior to approval. /' 60 )70 REINSPECTION FEE \tEQUIR€O. Prior to inspection, fee must be p d at 6300 Southcenter B d., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: 64A. 4 r,,, q Type of Inspection: Address: Suite #: 147rifvqt, a. .Contact Person: Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fir Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Inspector: Approved per applicable codes. �a.�e- /MSY Date: ��D�U9 COMMENTS: 4101 — 01< s J. ri Corrections required prior to approval: Word /Inspection Record Form:Doc H rs:: j $80.00 REINSPECTION FEE REQUIRED. u will receive an invoice from he City of Tukwila Finance Department. Call to scheduie..a reinspection. 1/13/06 T.F.D. Form F.P. 113 ACTIVITY NUMBER: M09 -077 DATE: 06 -17 -09 PROJECT NAME: GATEWAY BLDG 7 (ROOF ONLY) SITE ADDRESS: 12720 GATEWAY DR X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: OL kW( Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Please Route TUES /THURS ROUTING: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documentshouting slip.doc 2 -28-02 • PERMIT COORD COPY. PLAN REVIEW /ROUTING SLIP Ali. km, Lo -0 1 Fire Prevention Planning Division ❑ Structural n Permit Coordinator Incomplete DUE DATE: 06 -18 -09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined Incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: Structural Review Required No further Review Required U DATE: DUE DATE: 07 -16 -09 Approved Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: u Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ File ❑ Ping ❑ PW ❑ Staff Initials: License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI *988RC DIVCO INCORPORATION CONSTRUCTION CONTRACTOR GENERAL UNUSED 12/3/2002 11/7/2010 ACTIVE MACDOMR026RU MACDONALD MILLER RSDNTL INC CONSTRUCTION CONTRACTOR UNUSED GENERAL 12/31/1998 12/31 /2001 ARCHIVED MACDOMR076OPMILLER MACDONALD RESIDENTIAL CONSTRUCTION CONTRACTOR GENERAL UNUSED 9/17/1993 12/30/1998 ARCHIVED DIVCOEC188LC DIVCO ENERGY CONTROL COMPANY CONSTRUCTION CONTRACTOR GENERAL UNUSED 6/3/1982 5/26/1997 ARCHIVED MACDOM *248J9 MACDONALD MILLER CO CONSTRUCTION CONTRACTOR GENERAL UNUSED 4/29/1976 2/1/2002 ARCHIVED ENCOMMS984CA ENCOMPASS MECHANICAL SERVICES CONSTRUCTION CONTRACTOR GENERAL UNUSED 2/1/2002 2/1/2004 EXPIRED LINFOAR980QG LINFORD AIR a REFRIGERTN INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 11/7/2002 11/7/2004 INACTIVE DIVCOI*031L4 DIVCO INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 6/24/1997 8/1/2003 REREGISTERED Untitled Page • I General /Specialty Contractor A business registered as a construction contractor with MI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MACDONALD /MILLER FAC SOL INC 2067684180 PO BOX 47983 SEATTLE WA 98106 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602254260 ACTIVE MACDOFS980RU CONSTRUCTION CONTRACTOR 12/31/2002 12/31/2010 GENERAL UNUSED Other Associated Licenses Page 1 of 2 Business Owner Information Name Role Effective Date I Expiration Date https://fortress.wa.gov/lni/bbip/Detail.aspx 06/25/2009 DAMPER LEGEND SYMBOL DESCRIPTION- POWERED SYMBOL DESCRIPTION -NON POWERED FSD 10 HFSD TFSD FSD HFSD SD MD SCD AD 1 1/2 HOUR VERTICAL COMBINATION FIRE/SMOKE OR EQUAL 4 0 H[} © HFD FD . BDD 's BAR L- 1 1/2 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER GREENHECK DFD 150 OR EQUAL 1 1/2 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER GREENHECK FSD 212 (2000 FPM) GREENHECK FSD 312 (3000 FPM) OR EQUAL 1 112 HOUR HORIZONTAL COMBINATION FIRE/SMOKE FSD FPM) OR EQUAL GREENHECK DFD 150 (HORIZONTAL MOUND OR EQUAL 3 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER GREENHECK 212 (2000 GREENHECK FSD 312 (3000 PPM) OR EQUAL 1 1/2 HOUR TUNNEL CORRIDOR COMBINATION FIRE/SMOKE GREENHECK DFD 350 OR EQUAL 3 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER GREENHECK CFSD 212-1 OR EQUAL © 3 HOUR VERTICAL COMBINATION FIRE/SMOKE GREENHECK FSD 231 OR EQUAL 3 HOUR HORIZONTAL COMBINATION FIRE/SMOKE GREENHECK DFD 350 (HORIZONTAL MOUNT) OR EQUAL CEILING RADIATION DAMPER GREENHECK CRD -2 OR EQUAL BACKDRAFT DAMPER OR GREENHECK FSD 231 OR EQUAL SMOKE DAMPER ,- GREENHECK WD 330 (VERT) WD -100 (HORIZONTAL) OR EQUAL BAROMETRIC RELIEF DAMPER (.05 OPNG PRESSURE SHOWN) © GREENHECK SMD 202 OR EQUAL MOTORIZED CONTROL DAMPER RUSKIN CBD2 NO SUBSTITUTE ALLOWED VOLUME DAMPER SHOP FABRICATED, WI LOCKING QUADRANT ® GREENHECKVCD -23 OR EQUAL SMOKE CONTROL MOTORIZED DAMPER GREENHECK SMD 301 OR EQUAL . INTERLOCK WITH FIRE ALARM BY ELECTRICAL CONTRACTOR ACCESS DOOR >I 18 "x 18" MINIMUM THROUGH BUILDING CONSTRUCTION BY GENERAL CONTRACTOR GENERAL NOTES: COMBINATION FIRE/SMOKE DAMPER REQUIREMENTS (UNLESS OTHERWISE NOTED): - CLASS II - 165° FUSIBLE LINK - FAIL - CLOSE, 120V ACTUATOR - ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR - INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR FIRE DAMPER REQUIREMENTS: - BLADES OUT OF AIRSTREAM ON MEDIUM PRESSURE DUCTS -165 F FUSIBLE LINK - CLASS ll FITTING GENERAL NOTES PIPING MATERIAL SCHEDULE: PIPING SIZE MATERIAL JOINT NATURAL GAS 1/2" - 2" SCH 40 BLK STL ASTM A53 A OR B THREADED, FLANGED, SOCKET WELDED 120W ESP (IN) RPM SOUNDLINE SHEETMETAL (1" LINING) 2 -112" -10" SCH 40 BLK STL ASTM A53 A OR B BUTT WELDED FLANGED, 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE MECHANICAL CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 IBC, IMC, AND UPC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. 3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. 4. SLOPE ALL INDIRECT DRAINS AT 2% UNLESS OTHERWISE NOTED ON DRAWINGS. OBTAIN APPROVAL FROM CODE AUTHORITY BEFORE INSTALLING PIPING AT LESS THAN 2% (EVEN IF LESSER SLOPE IS INDICATED ON DRAWINGS). 5. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH THE 2006 IMC AND IBC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. 6. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 7 PROVIDE SHUT -OFF VALVES AT ALL EQUIPMENT CONNECTIONS. 8 PROVIDE UNION, GROOVED OR FLANGED CONNECTION AT EQUIPMENT FOR FUTURE REMOVAL AND SERVICING. 9 FOR CONDENSATE PIPING PROVIDE TRAPS WITH A MINIMUM SEAL 2" GREATER THAN THE FAN OPERATING STATIC PRESSURE AT ALL COOLING COIL CONNECTIONS. 10 PROVIDE MINIMUM 1 " AIR BREAK FOR ALL CONDENSATE PIPE TERMINATIONS AT DRAINS. 11 PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. DUCT LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL ELECTRICAL ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") SUPPLY CFM 14/12 120W ESP (IN) RPM SOUNDLINE SHEETMETAL (1" LINING) VOLT/ PH CLEANROOM QUALITY DUCTWORK RTU -101 14/12 SL 14/12 C 20,000 3,680 SHEETMETAL WRAPPED W/ INSULATION (2 ") 1.2 BARE FLAT OVAL SHEETMETAL 4 @1 11,700 HP CFM EACH 14/12 W 14/12a- 150 NEW, EXIST REPLACE 1 -5 , BARE ROUND SHEETMETAL CARRIER 48DF -064 SERIES# 640PA SERIAL# ¥883274 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") CARRIER 48DF -064 SERIES# 640PA SERIAL# Y883274 120 14/129W , EXPOSED QUALITY SHEETMETAL DUCTBOARD (1" FIBERGLASS) 14/12 0 14/12 DB CARRIER 48TJDd14 SERIES# 601 QE SERIAL# 4194G30497 SOUTH WING EXAMPLE OF NEW CARRIER 48TJD014 SERIES# 601 QE SERIAL# 4194G30497 EXAMPLE OF NOT IN CONTRACT (NIC) - 14/2 14/12 EXAMPLE OF DEMO x FLEX DUCT - % x % x EXAMPLE OF EXISTING FLEX CONNECTOR 14/12 # # PACKAGED GAS /ELEC AIR CONDITIONING ROOFTOP UNIT SCHEDULE UNIT NO. MFG & MODEL NO. AREA SERVED FANS WEIGHT (LBS) ELECTRICAL NOTES SUPPLY CFM MIN OA (CFM) SUPPLY MOTOR (HP) ESP (IN) RPM POWER EXH MOTOR VOLT/ PH MCA RTU -101 CARRIER 48AKT05ODSQ611HM EAST WING 20,000 3,680 1 @30 HP 1.2 1242 4 @1 11,700 HP CFM EACH 6,658 460/3 150 NEW, EXIST REPLACE 1 -5 , RTU -102 CARRIER 48DF -064 SERIES# 640PA SERIAL# ¥883274 NORTH WING CARRIER 48DF -064 SERIES# 640PA SERIAL# Y883274 60 EXISTING RTU -103 CARRIER 48TJDd14 SERIES# 601 QE SERIAL# 4194G30497 SOUTH WING RTU -103 CARRIER 48TJD014 SERIES# 601 QE SERIAL# 4194G30497 EXISTING UNIT NO. MFG & MODEL NO. COOLING HEATING FILTERS COOLING TOTAL (TONS) COOLING TOTAL (MBH) COOLING SENS (MBH) EER/ SEER IPLV REFER TYPE HEAT INPUT (MBH) HEAT OUTPUT (MBH) STAGES ( #) AFUE ( %) QTY ( #) SIZE (IN) RTU -101 CARRIER 48AKTO50DSQ611 HM 50 600 456 9.3 9.5 R -22 800 656 5 82 5 20x20x4 RTU -102 CARRIER 48DF -064 SERIES# 640PA SERIAL# Y883274 60 RTU -103 CARRIER 48TJD014 SERIES# 601 QE SERIAL# 4194G30497 N ai 0 NOTES: 1. ELECTRICAL DISCONNECT SWITCH AND POWER WIRING BY ELECTRICAL CONTRACTOR. 2. VFD MOTORS 3. FEATURES AND OPTIONS INCLUDED: - COMFORTLINK CONTROLS WITH VISUAL SCROLLING MARQUEE DISPLAY - HIGH GAS HEAT WITH STAINLESS STEEL HEAT EXCHANGER/BURNER - AUCU COND AND EVAP - DIFFERENTIAL DRY-BULB ECONOMIZER - FACTORY INSTALLED POWER EXHAUST (11,700 CFM) - HOT GAS BYPASS - LONWORKS TRANSLATOR CONTROLS INTERFACE - RETURN AIR SMOKE DETECTOR - 115V FACTORY WIRED CONVENIENCE OUTLET - CO2 SENSOR 4. MAXIMUM SOUND POWER LEVEL OF 99 DECIBELS RATED IN ACCORDANCE WITH ARI STANDARD 270 5. NEW UNIT WEIGHT (6,658 LBS) IS LESS THAN UNIT REPLACED (6,800 LBS). NO STRUCTURAL REVIEW REQUIRED PER CITY OF TUKWILA. r ; to K 1 . •. MacDonald - Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206 -767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU PERMIT SET 11 -12 -07 REVISIONS: 12720 GATEWAY DR S TUK WILA WA 98168 DRAWING NUMBER: E -0182- 7376672 -00 HVAC GENERAL NOTES 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. 4. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1`112" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R -4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). 5. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON- PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 8' IN LENGTH UNLESS NOTED OTHERWISE. 6. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1621 OF THE 2006 IBC. 7. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 8. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 9. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BYTHE GENERAL CONTRACTOR. 10.MOTOR STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 11. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 12.OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 13.COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC-2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 14.A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WTfH THE OWNER. HVAC ABBREVIATIONS ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID 1NT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD -M ILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUITAMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL OSA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OD OUTSIDE DIMENSION RA RETURN AIR REG REGISTER (GRILLE WITH DAMPER) REQ'D REQUIRED RIO ROUGH IN ONLY SA SUPPLY AIR SCD SMOKE CONTROL DAMPER SD SMOKE DAMPER SL SOUND LINING SM SHEET METAL SP STATIC PRESSURE SS START /STOP SSSC SOLID STATE SPEED CONTROLLER STL STEEL SUC SUCTION LINE SUSP SUSPENDED TSTAT THERMOSTAT TC TEMPERATURE CONTROL TOD TOP OF DUCT TOS TV TWG TWR TYP UNO VD VFD TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER DRAWING SHEET INDEX NAME TITLE NAME TITLE TM0.01 SCHEDULES - HVAC TM0.01S SITE MAP TM2.03 ROOF PLAN AND ELEVATION - HVAC APN # 2716000070 LEGAL DESCRIPTION LEGAL DESCRIPTION: GATEWAY CORPORATE CENTER PARCEL B OF CITY OF TUKWILA SHORT PLAT NO 89 -1-SS RECORDING NO 8904120877 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER CONTACT LIST TITLE NAME COMPANY PHONE NUMBER FAX NUMBER PROJECT MANAGER PROJECT ENGINEER SHEETMETAL FOREMAN AIR BALANCE FOREMAN ELECTRICAL FOREMAN CONTROLS FOREMAN REFRIGERATION FOREMAN STEVE FUNK CHRIS LEE LARRY HARBISON BRAD SHARP MIKE MCGIVERN SABRINA WORKMAN STEVE HARBISON OPERATIONS MANAGER GREG COLEMAN MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER RREEF 253 -681 -3172 206-768-4266 206- 423 -4294 206 - 768 -4112 206- 768 -4046 206 - 768 -4074 206 - 768 -4032 206- 788 -4404 206 -768- 253 -681 -3173 206 -768 -4267 206-768-4295 206 - 768 -4047 206- 768 -4075 206 - 768 -4033 SCOPE OF WORK REPLACE (1) EXISTING PACKAGED ROOFTOP UNIT, INCLUDES NEW M -M CUSTOM FABRICATED CURB ADAPTER. RECONNECT EXISTING NATURAL GAS LINE TO NEW ROOFTOP UNIT. ELECTRICAL DISCONNECT /CONNECT FOR NEW ROOFTOP UNIT. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Plan the of r FILE COPY ft WI+ ar anY COPYWd ay ( --- /o1 D CM SEPARATE PERMIT REQUIRED FOR: D Me hanIcal electrical C] P pmbing CCos Piping City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUNE 17 2009 PERMIT CENTER REVIEWED • E COM' CE APPROVED JUN 2 3 2009 City ofTukWii BUILDING DIVISION M um"- 0 SCHEDULES - HVAC ENGINEER: C LEE CHECK T ,AST RASED: 11 -12 -07 DATE PLOTTED: B GEZON 11 -12 -07 CAD: ISSUE DATE: D IKERD SHEET NUMBER TM0.01 0 0 0 z LSE 0 0 C CNT L- CD E 0 0 0 0 -4- (13 0 1•109%- 07 7 REVIEWED FOR E COMP APPROVED JUN 2 3 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKVVILA JUN; t7 2009 PERMIT CENTER MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU PERMIT SET REVISIONS: DATE 11-12-07 GATEWAY BLDG 7 SITE MAP ENGINEER: C LEE CHECKED BY: B GEZON CAD D IKERD DRAWING NUMBER: E-0182-7376672-00 NOT ISSUED FOR CONSTRUCTION E SHEET NUMBER- TM0.01S (1) 1— = 0 z IJ 0 CO 0 0 cn N. O O N I- E 0 z 0 0 C 0 N O O SCALE: Ys = 1' -0 2\ ROOF PLAN - HVAC [ RTU -102 EN GENERAL NOTES: FLAG NOTES: RTU -1 O1 )/,\ RAP ET WALL MacDonald - Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206-767-6773 www.macmiller.com WA Lic No: MACDOFS980RU PERMIT SET REVISIONS: 11 DATE GATEWAY BLDG 7 ENGINEER: LAST REVISED: C LEE 11 -12 -07 CHECKED $t: DATE PLOTTED: B GEZON 11 -12 -07 CAD: ISSUE DATE: D IKERD DRAWING NUMBER: E -O 182- 7376672 -00 SHEET NUMBER: TM2.03 1. NOT ALL ROOF- MOUNTED EQUIPMENT IS SHOWN. CARRIER WEATHER MAKER SINGLE - PACKAGED 40 -TON ROOFTOP UNIT. MODEL# 48DF -054. SERIES# 640PA. SERIAL# X889715. [EXISTING] REPLACE W /50 TON MODEL CARRIER 48AKTO5DSQ611HM. CARRIER WEATHER MAKER SINGLE- PACKAGED 60 -TON ROOFTOP UNIT. MODEL# 48DF -064. SERIES# 640PA. SERIAL# Y883274. [EXISTING] CARRIER WEATHER MAKER SINGLE - PACKAGED ROOFTOP UNIT. MODEL #, 48TJD014. SERIES# 601 QE. SERIAL# 4194630497. [EXISTING] A -A ;TM2.0 SCREEN WALL `N WALL / RTU -101 NORTH ELEVATION NO SCALE REVIEWED E COMP APPROVED JUN 2 3 2009 City of Tu BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN, 72009 PERMIT CENTER 0 a J N N. CI 0 O U) tn a O O z ti 0