Loading...
HomeMy WebLinkAboutPermit M09-091 - PEARSON VUEThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M09 -091 Pearson Vue 12720 Gateway Drive RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page Code Exemption = 8rlef E plainatoty Desclriptim Statuteftle The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 34 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. PEARSON VUE 12720 GATEWAY DR M09 -091 Parcel No.: 2716000070 Address: Suite No: 12720 GATEWAY DR TUKW Tenant: Name: PEARSON VUE Address: 12720 GATEWAY DR SUITE 200 , TUKWILA WA Owner: Name: RREEF AMERICA REIT II CORP/ Address: PO BOX 4900 #207 , SCOTTSDALE AZ Contact Person: Name: MIKE NELSON Address: 899 WEST MAIN , AUBURN WA Contractor: Name: IECS INC Address: 899 W MAIN ST , AUBURN WA Contractor License No: IECSI * *008C8 DESCRIPTION OF WORK: INSTALL (2) 1 1/2 TON AND (1) 4 TON DUCTLESS SPLIT A/C UNITS Value of Mechanical: $16,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 2 0 0 0 0 0 0 0 * * continued on next page ** M09 -091 • Permit Number: M09 -091 Issue Date: 09/21/2009 Permit Expires On: 03/20/2010 Phone: Phone: 206 - 255 -0045 Phone: 253 939 -9495 Expiration Date: 02/28/2010 Fees Collected: $363.81 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 09 -21 -2009 Permit Center Authorized Signature: I hereby certify that I have read and ex governing this work will be complied v The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performan of work. I am authorized to sign and obtain this mechanical permit. Signature: City of Tukwila 0■11 Date: c ? e '' 2 ' ~ c c Print Name: 4.4 ( k doc: IMC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite 14100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M09 -091 Issue Date: 09/21/2009 Permit Expires On: 03/20/2010 Date: [IA t o‘) ed this permit and know the same to be true and correct. All provisions of law and ordinances L th, hether specified herein or not. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -091 Printed: 09 -21 -2009 Parcel No.: 2716000070 Address: Suite No: Tenant: PEARSON VUE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12720 GATEWAY DR TURIN PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M09 -091 ISSUED 07/22/2009 09/21/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M09 -091 Printed: 09 -21 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: W eke_ �.(/ . ce/L,V doc: Cond -10/06 M09 -091 Date: ordinances governing or local laws regulating Printed: 09 -21 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us SITE LOCATION Site Address: 12720 GATEWAY DRIVE Tenant Name: PEARSON vuE Property Owners Name: RREEF PROPERTY MGMT. Mailing Address: 12720 GATEWAY DRIVE, SUITE 200 TUKWILA WA. 98168 Name: MIKE NELSEN Mailing Address: 899 west main Auburn wa. E -Mail Address: seattlemechanical @msn.com Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Contact Person: E -Mail Address: City City Building Permit No. Mechanical Permit No: _ ;; (�C — dq . Plunibing/Gas Permit No. Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: 2716000070 Suite Number: 200 Floor: 2 New Tenant: ❑ Yes [ . No State CONTACT PERSON — who do we contact when your permit is read; to be issued Day Telephone: 206-255-0045 State Fax Number: 253- 939 -9260 GENERAL CONTRACTOR IiNFORMATION — : (Contractor Information for Mechanicali(pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State ARCHITECT OF RECORD — plans must biwet stainped by Architect of Reeord Company Name: Mailing Address: City Day Telephone: Fax Number: State State Zip Zip Zip Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:Wpplications\Fotms- Applications On Line\3-2006 - Permit Application.doc Revised: 9 -2006 bh Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 3 Incinerator — Comm /Ind MECHANICAL PERMIT INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: IECS INC Mailing Address: 899 WEST MAIN AUBURN WA. 98001 City State Zip Day Telephone: 253-939-9495 Fax Number: 253- 939 -9260 Expiration Date: 11/13/08 Contact Person: TERRY COURSE E-Mail Address: SEATTLE MEHCANICAL Contractor Registration Number: 1 ECS * * * 044 QL Valuation of Mechanical work (contractor's bid price): $ 16000 Scope of Work (please provide detailed information): INSTALL TWO 1.5TON AND ONE 4 TON DUCTLESS SPLIT A/C UNITS Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ....171 Replacement .... ❑ Fuel Type: Electric ® Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Q:Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNS O A HORIZED AGENT: °j Signature: / � / Date: / — 2 / Print Name: wIfI ,k . 'Lie Ie4t) Mailing Address: % (' W � + C( t Date Application Expires: Date Application Accepted: --/- 6)-) .-off Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh A LLbt,r 4 City Day Telephone: 21)6- Ci `-f State Zip Staff Initials: Page 6of6 Parcel No.: 2716000070 Address: Suite No: Applicant: PEARSON VUE Receipt No.: R09 -01630 JEM 1165 IECS Initials: User ID: Payee: TRANSACTION LIST: Type Method Payment Cash Authorization No. ACCOUNT ITEM LIST: Description doc: Receiot -06 MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us 12720 GATEWAY DR TUKW Descriptio Amount Account Code RECEIPT 60.00 000.322.102.00.00 Payment Date: Balance: Total: $60.00 09293n1 000 7 10/20/2009 001 101 DC[: Permits Plus. - General Fund R09 01630 60.00 Permit Number: Status: Applied Date: Issue Date: Payment Amount: Current Pmts 60.00 $60.00 M09 -091 ISSUED 07/22/2009 09/21/2009 10/20/2009 10:17 AM $0.00 City of Tukwila 6200 Southcenter Blvd, Tukwila, WA 1 Finance Department 0929301 -1 10/20/2009 BR1 T101 Tue Oct20,2009 10:23AM Trans #7 -7 7 $60.00 DCDGEN - DCD Per its Plus General Fund ID: R09 01630 1 ITEM(S): TOTAL: $60.00 Cash PAID $100.00 CHANGE DUE: $40.00 www.ci.tukwila.wa.us 206 - 433 -1835 Printed: 10 -20 -2009 Parcel No.: 2716000070 Address: 12720 GATEWAY DR TUKW Suite No: Applicant: PEARSON VUE Receipt No.: R09 -01473 Payee: IECS, INC. ACCOUNT ITEM LIST: Description MECHANICAL - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Check 44599 291.05 Authorization No. RECEIPT Initials: JEM Payment Date: 09/21/2009 12:13 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Account Code Current Pmts 000.322.102.00.0 291.05 Total: $291.05 • Permit Number: M09 -091 Status: APPROVED Applied Date: 07/22/2009 Issue Date: Payment Amount: $291.05 PAYMENT RECEIVED doc: Receipt -06 Printed: 09 -21 -2009 Parcel No.: 2716000070 Address: 12720 GATEWAY DR TUKW Suite No: Applicant: PEARSON VUE Receipt No.: R09 -01146 Payee: IECS ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Check 44511 72.76 Authorization No. RECEIPT Initials: WER Payment Date: 07/22/2009 04:00 PM User ID: 1655 Balance: $291.05 TRANSACTION LIST: Type Method Descriptio Amount Account Code Current Pmts 000/345.830 72.76 Total: $72.76 Permit Number: M09 -091 Status: PENDING Applied Date: 07/22/2009 Issue Date: Payment Amount: $72.76 pkyMENT RECEIVED doc: Receiot -06 Printed: 07 -22 -2009 Pro'e Type of Inspectio . Address: el--r-M0 6` A , 7`i Date Called: Special Instructions: Date Wanted: l`� - - 22,-10 p.m. Requester: Phone No: COMMENTS: Date: 'Date: INSPECTION RECORD t Retain a copy with permit INSPECTIuN NO. Q._PERMIT NO / CITY 0 TUKWILA BUILDING DIVISION - !� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 367 ‘ TIlApproved per applicable codes. Corrections required prior to approval. G 72 -(i) $6 i, 00 REINSPECTION FEE EQUIRED. P for to inspection, fee must be pa' s at 6300 Southcenter Blvd., Suite 10 . Call to schedule reinspection. Pro $ t: 1 C e..» /- Jv A Vtib Type�pf InNaection: ��� I'CP 7� i i'Crie �) 1 Address:t -i 6±,--- Date Called: Special Instructions: 0 (� / v" 0 f Date Wanted: a.ly v ' U P.m. Requester: Phones N 6 2.s . 3 ...... n 4 �� o: r t5 � INSPECTION RECORD Retain a copy with permit INSP ION NO. 12_PEFIMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 OMM S: -641fe Dat j 60.00 REINSPECTION FEE EQUIRED rior to inspection, fee must be paid at 6300 Southcenter Blv Suite 00. Call to schedule reinspection. Receipt No.: r 'Date: Approved per applicable codes. Corrections required prior to approval. 6 COMMENTS: r � ` l`7 / 4 J 1 ..I ` ir - e \U s 4 (A ." / e IW I ._ ,t 0 -}-P s.. e L o Cr � . 'Q r A t `,. Pt t- �s r — c� 1 Address: z � 1° -C f f f F�-�- L v e S — nA u--4. -k- b P Date Called: 1� A 1.0* \-1 ( J . l , k Y ° c e 4 J +A e Q- kilt 4* 4 Date Wanted: / u - Z `-6 m: ���.....\/,, l ‘-(v t3 , �VS ( t o4e• F(rY'{✓`c ( S 1 ` 3 S41"" 4- 40 ../ UJ A -} u\ JL C m c. t NA../v)-e) Phone No: kl.♦., 41— \ZYla.4l( 1v�� 5 / J f' 1 pVcoa t e. 0 ( 4t9 Q 4 Lie ,i Prod t: R-501 V PION r Typ of Inspection ;F A-rQ ✓Vl0,f_11 Address: Date Called: Special Instructions: 03 (p to ID 0 ( 4 Date Wanted: / u - Z `-6 m: Requester: Phone No: tn pe or: , p Re 4ipt No.: �,,,,, ! INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Date: Ib -Za- 0.00 REINSPECT! N FEE REQUIRED. Prior to inspection, fee rfiust be id at 6300 Southce ter Blvd., Suite 100. Call to schedufe.celnspection. Date: PERMIT NO. Prssject: to AiSON VII Type of Inspection: ` FIl4 Address: 1 2TLC) OAT F w 6-I ,D2 Date Called: Special Instructions: Date Wanted: �a.rt I O -- Za —OS Requester: Phone No: X0 CO 2255 -ob i' INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. Corrections required prior to approval. COMME -BITS: n • ector INSPECTION RECORD Retain a copy with permit 41.0 A (3 - 1 a AO('E� j +v & A \g-r) $61.00 RE ' SPECTLON FEE RE UIRED. Prior pa d at b • ' 0 Southcenter Blvd., uite 100. Cal Rec ' • t • .: ate: kot Date: 3 2c) PERMIT NO. (206)431 -367 o inspection, fee must be to schedule reinspection. DL- Job Name: 1 e�G. U (rte U t t-,,f Location: ictin a !4 Date: 6 . oC, Purchaser: Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction Unit Designation: F 6.-1 Lv -7 Schedule No.: GENERAL FEATURES • Limited warranty: one year on parts and defects and six years on compressor • Compact side discharge outdoor unit • Zone control • Wireless remote controller • Automatic fan speed control • Q Pe Quiet operation —both indoor and outdoor units • Auto restart following a power outage • Self check function • Advanced microprocessor control Rated capacity 18,000 Btu /h Minimum capacity 8,000 Btu /h Total input........ .2240 W SEER . . . . . . .... 14.1 Power supply 208 / 230V, 1 Phase, 60 Hz Breaker size .... .. . 15 A Voltage Indoor - outdoor S1 -S2 ... AC 208/230V Indoor - outdoor S2 -S3 DC 24V Indoor - remote controller DC Indoor unit MCA 1 A Fan motor 0.33 F.L.A. Fan motor output 30 W Airflow (Lo- M1- M2 -Hi) 320 - 350 - 390 -425 Dry CFM 290 - 315 - 350 -380 Wet CFM Sound level (Lo- M1- M2 -Hi) 36- 38 -41 -43 dB(A) DIMENSIONS INCHES MM Controller t: • •. wa . '° : • -: . .. � .. ' :::..a � ` .:% - t r. ,1 •L r `:St' ; u ,`. F Y 1 r� may t. • - ^- ' a Unit: PUY- A18NHA /twin rotary ..13 0.35 F.L.A. 46 dB(A) MM _ Indoor Und: PKA.A18GAl x ., 15 1:•,.. Outdoor Outdoor unit Compressor DC inverter MCA Fan motor Sound level....... .. DIMENSIONS INCHES W 31-1/2 800 D 13 + 7/8 330 + 23 H 23-5/8 600 Weight (Ibs /Kg) 90 / 41 Refrigerant type R410A Refrigerant pipe size O.D. (inches /mm) gas side 1/2 / 12.7 liquid side . 1/4 / 6.35 Max. refrigerant pipe length (ft/m) 100 / 30 Max. refrigerant pipe height difference (ft/m) 100 / 30 Connection method flared NOTES : •1. Rating conditions (cooling)- indoor : D.B. 80 ° F, W.B. 67 °F outdoor : D.B. 95 °F, W.B. 75 °F. Operating range W 39 990 D 9 -1/4 235 H 13 - 3/8 340 Weight (Ibs /kg) .... 35 / 16 Field drain pipe size I.D. (inches /mm) 3/4 / 19.05 Indoor intake air temp. Outdoor intake air temp. Cooling Maximum D.B. 95 °F, W.B. 71 °F D.B. 115 °F Minimum D.B. 67 °F, W.B. 57 °F D.B. 0 °F • REVIEWED FOR CODE COMPLIANCE APPROVED I With wind baffle installed. 11 not installed, the minimum rated temperature is 23`F09. , "tie' , IN R Note JUL Z 8 2009 City of Tukwila 0/ ' RECEIVED RI III num nIVIgInni `� JUL 22 2009 MITSUBISHI L. ,ELECTRIC iVAAC Advanced Products Division j I, 1' 1l f . FILE COPY for Uf��i�. Sp It-ductless A/C and Heat Pumps PERMIT CENTER Eton1 view 1- 311321501 2 &5 hi make t 1/3212801 9 3/16/2331 Ai Nike 3-5/32(80) t 8.21/3212251 I 3919901 \ Ave vire f ront view (top open the grille) (Raabe ruse nw Ieryth 31.12 0 :=C1541 1a•_LI.Ei2irIr ..FA uci 0 Gas v_ 011 side dare nsu wcm) C SD - PKA- A18GAL / PUY- A18NHA - B - 200604 ® MITSUBISHI ELECTRIC / HVAC 2006 150<5.29t32 267.541.1//32> 10r2Y32> I 11111111111111111111111111 11111111 11111111111111111111111111111111111111 111111111111111 111111111111111111111 1111111111 11111111111 111111111111111 11111111111111111111111111111111111111 11111111111111111111111111111111111111 11111111111111111111111111111111111111 1111111 tei SON/911/16> 600431.12' Pi 6942.23/32, MITSUBISHI ELECTRIC HVAC Advanced Products Division Mitsubishi Electric 8 Electronics USA. Inc 3400 Lawrenceville Suwanee Rd Suwanee, GA 30024 Tele: 678- 376 -2900 • Fax: 800 -889 -9904 ToII Free: 800 -433 -4822 (*13) www.mehvac.com Specifications are subject to change without notice. 40QAC048 with 38HDR048 13 SEER Underceiling System Performance' Series Cooling Only with Puron ®Refrigerant Job Data: Pcu rSe i n I ; e ,� Buyer: Buyer P.O.# Unit Number: CU-) E ( - L-- Model Number: 4 O (J( vy y 7 0 Oat o 4 r-- Performance Data Certified By: Date: ( -/ O Purron_ 400AC SYSTEM SIZE REFRIGERANT. PERFORMANCE Nominal Capacity (Btuh) SEER Moisture Removal Rate(Pints/hr) Airflow (Low/Med/I-ligh) SOUND PRESSURE (dBA) Indoor (Low/Med/High) Outdoor SOUND POWER (dBA) Indoor(Low/Med/High) Outdoor PERFORMANCE AT ACTUAL CONDITIONS: Attached ❑ Not Attached ❑ Thermostat Slim Line 7 -day Programmable: Flat Sot 7-day Programmable: Thermostat Super T2 5 -1 -1 Commercial: Remote Room Sensor Kit: Condensate Pump: Fresh Air Intake Kit: Submittal Data - 14 L✓A. Indoor Unit - 40QAC / Outdoor Unit - 38HDR (Unless otherwise indicated, data applies to both indoor and outdoor models) 48,000 13 13.0 1100 /1160/1200 NA / 55.3 / 56.3 . 61 NA / 66.3 / 67.3 72 Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Location: FEATURES • Mounting bracket • Electro mechanical controls • Auto restart after power failure • User selectable fan speeds plus auto • Cleanable filters • Motorized louvers • Accessory wired user interfaces • Capable of connecting to an Energy Management system • Up to 200 ft (61 m) total piping (accessories required) • Accessory fresh air intake kit • Low ambient operation down to -20 °F (28.9 °C) w /accessory • Accessory condensate pump • Power ventilation accessory • Limited Warranty: 1 -year parts / 5 -year compressor • Optional extended parts and labor warranty 048 ELECTRICAL .......... R -410A System Voltage 208/230 -1; 208/230 -3; 460 -3 V MCA Indoor .. .. ... Outdoor (208/230 -1 / 208/230 -3 / 460 -3) 28.7; 18.6; 8.6 MOCP Indoor 15 Outdoor (208/230 -1 / 208/230 -3 / 460 -3) 50; 30; 15 Fan Motor (Indoor) (FLA) . .. 1.6 CONTROLS Control Remote ... Wired Control Voltage . 24v Control Wiring (0 -75 ft.) 18 AWG Control Wiring (75 -200 ft.) ... . 16 AWG REFRIGERANT LINES (Insulate vapor line) Liquid Line (in.) OD . 3/8 Vapor Line (in.) OD 7/8 Metering/Control Device .. Piston at indoor unit • Refer to NEC and local codes for compliance requirements. Low Ambient Kit: Winter Start Kit: Crankcase Heater: Wind Baffle: Stacking Kit: Wall Mounting Kit: Carrier # Turn to the Experts. Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ Required ❑ Not Required ❑ UNIT SIZE OUTDOOR MODEL WIDTH (IN.) A HEIGHT (IN.) B DEPTH (IN.) C WEIGHT (LB) 048 38HDR048 - - -3 44 -9/16 43 -3/16 17 -1/16 278 048 38HDR048 - - -5 44 -9/16 43 -3/16 17 -1/16 278 048 38HDR048 - - -6 44 -9/16 43 -3/16 17 -1/16 278 UNIT SIZE INDOOR MODEL WIDT (IN.) HEIG B (IN.) DEP C (IN.) WEIGHT (LB) 48 400AC048 - - -3 71 -9/16 9 -15/16 23 -1/8 151 Fig. 1 — 40QAC Dimensions 1111111 1111111111111 1111111. 11 1111111 1 1111111111 1111111 111111111111 111111i 1111111 11111111!III 111111 �! 111111; tl lllll'Iilll rp1P,111111 1111111 ∎ : :!1111111111 1111111 Illilllllllll 1111111 1111111111111 oNNI FRONT VIEW B Copyright 2008 Camer Corp. • 7310 W. Morns 5L • Indianapolis, IN 46231 UNIT DIMENSIONS — INDOOR MODEL 3/8' DIA.(9.53) LIQUID LINE FEMALE SWEAT co. ON • M DIA VAPOR LINE CONK FEMALE SWEAT CONN. A ITT VIEW •,,,•, .,„, aNOU 1 11111111111111)011 1Mt1J1111! 111111111Y1111 1111111111111111111r x;111111111 1 IIIIII1N111IIIIINi11NIIIJII11 ilr 1111111 > iliilllll'I�'h!IIII11111111111 ��II II , 11 „, 111111 1hd1111 „, „, ai r 111' 111 WIND BAFFLE ACCESSORY 0'-0 11/16' DRAIN HOLES (TVP1 (1B) Fig. 3 — 38HDR DIMENSIONS Manufacturer reserves the right to change, at any lime, specifications and designs without notice and without obligations. 2 1?7 Y TYP c UNIT DIMENSIONS — OUTDOOR MODEL Pnnted in U.SA. Edition Date:12/08 BIDE VIEW Fig. 2 — 40QAC Clearance TOP VIEW 0' 7 1/2 (191) 0' , .2 1/2' (64) .4 3/16 (106) JUICY ON Mx RE F)IEICE) Catalog No: 40QAC48- 38HDR48 -4SB Replaces: 40QAC48- 38HDR•8 -3SB SUBMITTAL SHEET SYSTEM 18KHS72 KHS1872/CH1872 WALL MOUNTED HEAT PUMP POWER Circuit Ampacity, Min. Fuse Size, Max. COMPRESSOR No. used R.L Amps - L.R Amps Crankcase Heater OUTDOOR UNIT Fan- Type Dia. (in.) - No. used Type Drive - No. speeds No. Poles (RPM) No. Motors (W) CFM (High) F.L. Amps .(A) Coil - Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq. ft.) Tube Size (in) INDOOR UNIT Fan - Type Dia. & Length (in) - No. used No. Speeds No. Poles No. Motors CFM . F.L. Amps Coil - Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (inch) Drain Connection Size (in.) REFRIGERANT Lbs. - R410A (outdoor unit) Control Connection Line Length, Max Lift Difference. Max Line Size Line Size DIMENSIONS Indoor Unit Outdoor Unit WEIGHT Net Shipping SHIPPING VOLUME INDOOR/OUTDOOR General Data (AT 230/208V) (V /PH /HZ) (A) (A) (A) (W) (RPM, High) (W) (Hi/Me /Lo) (A) ............... 0.3 .. ..................... Alminum Fin & Copper Pipe Slit Plate - Inner Riffled (ft.) (ft.) (in., O.D. Discharge) (in., O.D. Suction) (in) Uncrated Crated Uncrated Crated (Ibs. ) (Ibs.) (cu.ft.) 230/208 / 1 / 60 20 20 DC Rotary 1 6 25/6 95 / 6 65/7.35 20 Propeller 16 -17/32 - 1 Direct -3 8 - 820 / 850 40 - 1 524 0.5 Alminum Fin & Copper Pipe Corrugated Plate - Inner Riffled 9/32" Cross Flow 3 -11/16 33 -9/32 - 1 3 & Auto 8 - 850/850 30 - 1 523/470/417 (Coolinlg) 9/32" 23/32" R410A 2.87 Electric Expansion Valve Flare 100 50 1/4" 1/2" H x W x D 11 -23/32 x 41 -15/16 x 8 -19/32 11 -3/8 x 44 -7/8 x 14 -29/32 Cooling 26 -3/8 x 34 -21/32 x 11 -7/32 29 -1/8 x 39 -27/32 x 14 -31/32 Heating Indoor Outdoor 26.5 97.0 33.1 105.8 Indoor Outdoor 4.24 9.89 17.5 COOLING Total Capacity Sensible Capacity Latent Capacity SEER Dehumidication Amps Power Inputs Outdoor Sound Rating HEATING Total Capacity HSPF Amps Power Inputs Back -up Strip Heater Outdoor Sound Rating FEATURE Controls Remote Controller Performance Data @ ARI Standard Conditions (230/208V) (BTUM) (BTU/H) (BTU/H) (PintslH) (A) (W) (bets) (BTU/H) (A) (W) (kW) (bels) Temperature Control Timer Night Setback Air Louver (Horizontal) (Vertical) Power Failure Automatic Restart Heating /Cooling Automatic Changeover Self- Diagnosis Quiet Operation Ion Generator Air Clean Apatite Filter OPTION Refrigerant Line Set Fresh Air Intake Airduct Extension Indoor Frame Extension Condensate Drain Pumpm Non - Removable Remo -con Bracket OPERATING RANGE CERTIFICATION Maximum Minimum Maximum Minimum 17,600 (4,100 - 17,700) 13,200 4,400 16 4.89 7/7.7 1,500 / 1,500 (250 - 1.500) 51 20,500 (4,400 - 20.500) 7.7 7.4/8.1(1.3 -8.1) 1,575 / 1,575 (270 - 1,575) 52 Microprocessor LCD Wireless Type Temperature Sensor Built -in IC Thermostat 24 Hr. Program, 1 Hr Off Built -in Manual Automatic Built -in Built -in Built -in Built -in Equipped Standard N/A N/A N/A N/A N/A Indoor Air Outdoor Air Intake Temp. Intake Temp. 95F DB / 71F WB 115F DB 67F DB / 57F WB 67F DB 80FDB /67FWB 75FDB /65FWB - DB / - WB OFDB 18KHS72 Ln Express: Load Calculation Software Load Express: Load Calculation Software By: Seattle Mechanical General Job Job Description: Building Owner: Program User: Comments: Program was Run: Dataset Name: Alternative 1 AIt1 Geographical Data Location: Weather File: Latitude: Elevation: Seattle, Washington Seattle, Washington 47 deg 386 ft REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 8 2009 City of Tukwila BUILDING DIVISION Pearson View Seattle Mechanical 7/22/2009# 1:22:12 PM C: \CDS\LOADEXPIDATA\PEARSON. LE Design Data Summer Dsn Dry Bulb Summer Dsn Wet Bult Winter Design Dry Bull Density -Sp Heat Produ Design Simulation peril FILE COPY 80.0 deg F 64.0 deg F 26.0 deg F 1.0988 Btu- min/(hr -ft3-F) Apr To Nov M09 o91 Version 2.2 Title Page Building Peak Data Month/Hour. Jul / 14 Cooling Capacity 85.0 Mbh Cooling Sensible: 66.7 Mbh Sensible Heat Ratio (SHF 0.864 Heating Capacity: 0.0 Mbh RECEIVED JUL 22 PERMIT CENTER ll,lt! Loud Express: Load Calculation Software Version 2.2 Zone/Air Handler Descriptions Alternative - 1 Alt1 Zone/Air Handler Descriptions Air Handler Type Description 1 CONSTANT AHU1 Zone Type Description 1 Commercial Retail Zone1 Load Express: Load Calculation Software Alternative 1 AIt1 General Job Data Weather Location: Seattle, Washington Weather Region: Northwest Cig Simulation Start Month: Apr Gig Simulation End Month: Nov Zone Data Alternative Number: 1 Zone Number: 1 Floor Width: 22 ft Floor Length: 43 ft Ceiling Height: 10 ft Fir -to -Fir Height: 14 ft No. of Dup Zones: 1 Ceiling U- Factor: 0.04 Btu /(hr- F -ft2) Floor Calculation Type: None W H WALL 1 22 x 10 WALL 1 22 x 10 GLASS 1 20 x 6 GLASS 1 20 x 6 ROOF 1 22 x 43 ROOF 1 22 x 43 PART 1 10 x 7 PART 1 10 x 7 PART 2 43 x 10 PART 2 43 x 10 PART 3 22 x 10 PART 3 22 x 10 Type 8" L.W. Concrete Blk, 6" Ins 8" L.W. Concrete Blk, 6" Ins Double Coated 1/4 in. Double Coated 1/4 in. Steel Deck, 5" Ins Steel Deck, 5" Ins Frame, 0.75" gypsum board Frame, 0.75" gypsum board Frame, 0.75" gypsum board Frame, 0.75" gypsum board Frame, 0.75" gypsum board Frame, 0.75" gypsum board 1 -2 Story Office Building Opening Time: 8 am Building Closing Time: 6 pm Building Direction: 0 Clg Sensible SF: 10.00 Cooling Dry Bulb: Relative Humidity: Heating Dry Bulb: People Density: People Activity: People Sensible Load: People Latent Load: Misc. Equip. Type: Misc. Equip. Sensible Load Misc. Equip. Latent Load: Misc. Equip. Sensible to RA Lighting Intensity: Lighting Type: ecessed fluorescent, not vented 0.04 Light 0.04 Light 0.50 0.50 0.05 Light 0.05 Light 0.39 0.39 0.39 0.39 0.39 0.39 0 Plenum 0 Plenum 0 RA 0 RA 72 deg F 50 % 70 deg F 30 people General Office Space 275 Btuh /pers 275 Btuh /pers Microcomputers 350.00 Watt/pers 0.00 Watt/ft2 0 Btuh 2.00 Watt/ft2 North North North Yes North Yes CIg Latent SF: 10 Htg Sensible SF: 10 People Diversity: 100 % Bldg Simulation Type: Cooling Only Version 2.2 Zone Input Data Ballast Factor: 1.00 % Percent Light to RA: 50 % Vent Type: General Office Space Vent Cool Design: 20.00 cfm /pers Vent Heat Design: 20.00 cfm /pers Supply Cool Design: 0 cfm Supply Heat Design: 0 cfm Infiltration Type: Pressurized, Average Construction Infilt. Cooling Desigi 0.30 ach/hr Infilt. Heating Desigi 0.30 ach /hr Room Exhaust: 0.00 cfm U- Factor Color Percent ( %) Direction Susp Ceil Tilt Cool Adj Heat Adj Dimension % Glass Shading Coeff Spc Temp Spc Temp degF deg F 0 0 0 O 0 0 O 0 0 Area O 0 0 Area O 0 0 0 0 0 0 80 60 0 80 60 0 80 60 0 80 60 0 80 60 0 80 60 0.00 0.00 0.55 0.55 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Shading No Shading No Shading Load Express: Load Calculation Software Air Handler Input Alternative 1 Air Handler 1 Fan Configuration: Blow Fan & Motor Efficiency: 56.00 % Cooling Supply Air Temp: 55.00 deg F Heating Supply Air Temp: 0.00 deg F Minimum Relative Humidity: 40 % Supply Fan Static Pressure: 2.50 in H2O Return Fan Static Pressure: 2.00 in H2O CONSTANT AHU1 Supply Duct Location: Supply Duct Insulation: Supply Duct Temp Rise: Return Duct Insulation: Return Duct Temp Rise: Terminal Type: Total Cool Airflow: Total Heat Airflow: Zone(s) Connected: Other User Defined 0.0 deg F TD No Duct Insulation 0.0 deg F TD CONSTANT 0 cfm 0 cfm 1 Version 2.2 Air Handler Input Load Express: Load Calculation Software versio2.2 Peak Load Information Alternative 1 Design Cooling: Airflow (cfm) Cooling Cooling Coil Total Outside % O.A. Total Sensible S.H.R. Entering Leaving ft2/ton cfm/ton cfm/ft2 Total Air Handler #/Type Btuh Btuh DB WB DB WB tons BLDG BLOCK 84,952.10 73,419.80 0.86 133.63 7.1 BLDG PEAK 84,952.10 73,419.80 0.86 133.63 7.1 1 CONSTANT 3,073.56 600.00 19.52 84,952.10 73,419.80 0.86 76.98 62.43 55.00 52.86 133.63 434.2 3.2 7.1 Building Peak Load Components Cooling (Btuh) Heating (Btuh) Mo/Hr: Solar Cond Internal OA +Inf Misc Total Cond OA +Inf Misc Total Bldg 7/14 2,073.2 4,072.9 56,207.7 7,497.3 7,378.1 77,229.2 Bldg 7/14 2,073.2 4,072.9 56,207.7 7,497.3 7,378.1 77,229.2 Air Hand 1 7/14 2,073.2 4,072,9 56,207.7 7,497.3 7,378.1 77,229.2 Zone 1 7/14 2,073.2 4,072.9 56,207.7 7,497.3 7,378.1 77,229.2 Air Hand 1 7/14 2,073.2 4,072.9 56,207.7 7,497.3 7,378.1 77,229.2 Zone 1 7/14 2,073.2 4,072.9 56,207.7 7,497.3 7,378.1 77,229.2 Load Express: Load Calculation Software Psychrometric State Points - Alternative 1 AIt1 Zone 1 Dry Bulb Wet Bulb Temp Diff. Zonel ( deg F ) ( deg F ) ( deg F ) Space 72.0 60.4 Zone Return Air Heat Pickup 1.0 Return Fan 1.3 Return Air 74.3 61.2 Outdoor Air 79.4 64.3 Retum/Outdoor Air Mix 75.4 61.9 Blow Through Fan 1.6 Entering Coil 77.0 62.4 Leaving Coil 55.0 52.9 Draw Through Fan 0.0 Supply Duct Heat Gain 0.0 Supply Air 55.0 52.9 Percent Outside Air Space Sensible Heat Ratio (SHR) Coil Airflow 21.47 % 0.868 2,794 cfm Version 2.2 Psychrometrics Load Express: Load Calculation Software Version 2.2 Sensible Load Profile Sensible Load Profile (Mbh} Alternative 1 AM Hour 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Air Hand 1 5 4 3 3 2 3 5 44 50 55 59 62 85 67 88 67 67 65 25 17 13 10 8 7 Bldg 5 4 3 3 2 3 5 44 50 55 59 82 65 67 68 67 67 65 25 17 13 10 8 7 Zone 1 5 4 3 3 2 3 5 44 50 55 59 62 65 87 68 67 67 65 25 17 13 10 8 7 Load Express: Load Calculation Software Peak Load Summary - Alternative 1 Air Hand 1 AHU1 Areas ( ft2 ) Floor. SlabOnG/ExFIr. Roof: Skylight: Wall: Wall Glass: Partition: 946.0 0.0 946.0 0.0 100.0 120.0 720.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 52,194.5 57,413.9 2,794 3,074 2.95 3.25 Btuh Btuh cfm cfm cfm/ft2 cfm/ft2 cfm cfm Version 2.2 Peak Load Summary Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 14 Outside Air: OADB: 79 WB: 64 RELHUM: 44.2% Cooling Coil Peak Heating Coil Peak Total Load ( Btuh) Sens Load Percnt of Tot ( Btuh ) ( %) Peak Tot Sens ( Btuh) Percnt of Tot ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 2,073.15 2,073.15 0.00 Sub Total 2,073.15 2,073.15 2.68 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 1,431.58 1.431.58 0.00 Glass 426.10 426.10 0.00 Wall -8.10 -8.10 0.00 Partition 2,223.36 2,223.36 0.00 SlabOnG /ExFIr 0.00 0.00 0.00 Sub Total 4.072.94 4,072.94 5.27 0.00 0.00 INTERNAL LOADS Lights 5,796.96 5.796.96 0.00 People 16.139.60 7,889.64 0.00 Misc 34,271.10 34,271.10 0.00 Sub Total 56,207.70 47,957.70 72.78 0.00 0.00 MISC LOADS Outside Air 6,949.47 4.878.77 0.00 Humidification 0.00 0.00 0.00 Infiltration 547.85 384.61 0.00 Sup. Fan Heat 4,989.54 4,989.54 0.00 Ret. Fan Heat 3,991.63 3,991.63 0.00 Duct Heat Pkup 0.00 0.00 0.00 Exhaust Heat - 1,603.09 - 1,603.09 0.00 Sub Total 14,875.40 12.641.50 19.26 0.00 0.00 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 77.229.20 66,745.30 0.00 W /Safety Factor 84,952.10 73,419.80 0.00 Load Express: Load Calculation Software Peak Load Summary - Alternative 1 Air Hand 1 AHU1 Areas ( ft2 ) Floor. SlabOnG/ExFIr. Roof: Skylight: Wall: Wall Glass: Partition: 946.0 0.0 946.0 0.0 100.0 120.0 720.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 52,194.5 57,413.9 2,794 3,074 2.95 3.25 Btuh Btuh cfm cfm cfm/ft2 cfm/ft2 cfm cfm Version 2.2 Peak Load Summary Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 14 Outside Air: OADB: 79 WB: 64 RELHUM: 44.2% Load Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Alternative 1 AM Bldg 1 Areas ( ft2 ) Floor. 946.0 SlabOnG/ExFlr: 0.0 Roof: 946.0 Skylight: 0.0 Wail: 100.0 Wall Glass: 120.0 Partition: 720.0 Heating Coil Peak Outside Air. OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 14 Outside Air: OADB: 79 WB: 64 RELHUM: 44.2% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) ( %) ( Btuh ) ( %) ENVELOPE LOADS • Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 2.073.15 2,073.15 0.00 Sub Total 2,073.15 2.073.15 2.68 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 1,431.58 1.431.58 0.00 Glass 426.10 426.10 0.00 Wall - 8.10 -8.10 0.00 Partition 2,223.36 2,223.36 0.00 SlabOnG /ExFIr 0.00 0.00 0.00 Sub Total 4.072.94 4,072.94 5.27 0.00 0.00 INTERNAL LOADS Lights 5.796.96 5.796.96 0.00 People 16,139.60 7.889.64 0.00 Misc 34.271.10 34,271.10 0.00 Sub Total 56,207.70 47,957.70 72.78 0.00 0.00 MISC LOADS Outside Air 6.949.47 4.878.77 0.00 Humidification 0.00 0.00 0.00 Infiltration 547.85 384.61 0.00 Sup. Fan Heat 4,989.54 4.989.54 0.00 Ret. Fan Heat 3,991.63 3.991.63 0.00 Duct Heat Pkup 0.00 0.00 0.00 Exhaust Heat - 1,603.09 - 1,603.09 0.00 Sub Total 14,875.40 12,641.50 19.26 0.00 0.00 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 77.229.20 66.745.30 0.00 W /Safety Factor 84,952.10 73.419.80 0.00 Load Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Alternative 1 AM Bldg 1 Areas ( ft2 ) Floor. 946.0 SlabOnG/ExFlr: 0.0 Roof: 946.0 Skylight: 0.0 Wail: 100.0 Wall Glass: 120.0 Partition: 720.0 Heating Coil Peak Outside Air. OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: 7 / 14 Outside Air: OADB: 79 WB: 64 RELHUM: 44.2% Load Express: Load Calculation Software Peak Load Summary - Alternative 1 Zone 1 Zone1 Areas ( ft2 ) Floor: SlabOnG /ExFlr: Roof: Skylight: Wall: Wall Glass: Partition: 946.0 0.0 946.0 0.0 100.0 120.0 720.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airfw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 52,194.5 57,413.9 2,794 3,074 2.95 3.25 Btuh Btuh cfm cfm cfm/ft2 cfm/ft2 cfm cfm Heating Coil Peak Outside Air: OADB: Version 2.2 Peak Load Summary 0 Cooling Coil Peak Peaked at Time: Mo/Hr. 7 / 14 Outside Air. OADB: 79 WB: 64 RELHUM: 44.2% Cooling Coil Peak Heating Coil Peak Total Load ( Btuh ) Sens Load Percnt of Tot ( Btuh ) ( %) Peak Tot Sens ( Btuh) Percnt of Tot ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 2.073.15 2.073.15 0.00 Sub Total 2,073.15 2,073.15 2.68 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 1.431.58 1.431.58 0.00 Glass 426.10 426.10 0.00 Wall -8.10 -8.10 0.00 Partition 2.223.36 2,223.36 0.00 SlabOnG /ExFlr 0.00 0.00 0.00 Sub Total 4.072.94 4.072.94 5.27 0.00 0.00 INTERNAL LOADS Lights 5.796.96 5,796.96 0.00 People 16,139.60 7,889.64 0.00 Misc 34.271.10 34,271.10 0.00 Sub Total 56,207.70 47,957.70 72.78 0.00 0.00 MISC LOADS Outside Air 6.949.47 4.878.77 0.00 Humidification 0.00 0.00 0.00 Infiltration 547.85 384.61 0.00 Sup. Fan Heat 4,989.54 4,989.54 0.00 Ret. Fan Heat 3.991.63 3.991.63 0.00 Duct Heat Pkup 0.00 0.00 0.00 Exhaust Heat - 1,603.09 - 1,603.09 0.00 Sub Total 14,875.40 12,641.50 19.26 0.00 0.00 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 77.229.20 66,745.30 0.00 W /Safety Factor 84.952.10 73.419.80 0.00 Load Express: Load Calculation Software Peak Load Summary - Alternative 1 Zone 1 Zone1 Areas ( ft2 ) Floor: SlabOnG /ExFlr: Roof: Skylight: Wall: Wall Glass: Partition: 946.0 0.0 946.0 0.0 100.0 120.0 720.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airfw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 52,194.5 57,413.9 2,794 3,074 2.95 3.25 Btuh Btuh cfm cfm cfm/ft2 cfm/ft2 cfm cfm Heating Coil Peak Outside Air: OADB: Version 2.2 Peak Load Summary 0 Cooling Coil Peak Peaked at Time: Mo/Hr. 7 / 14 Outside Air. OADB: 79 WB: 64 RELHUM: 44.2% MIKE NELSON 899 WEST MAIN AUBURN WA 98001 RE: Permit No. M09 -091 12720 GATEWAY DR TUKW Dear Permit Holder: Based on the above, you are hereby advised to: -or- Thank you for your cooperation in this matter. Sincerely, 7:A Bill Rambo Permit Technician File: Permit File No. M09 -091 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 04/20/2010. 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 04/20/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 a Fax: 206 - 431 -3665 ACTIVITY NUMBER: M09 -091 PROJECT NAME: PEARSON VUE SITE ADDRESS: 12720 GATEWAY DR X Original Plan Submittal Response to Correction Letter # DATE: 07 -22 -09 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: AY 641 Building ivisio Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Documents /routing slip.doc 2 -28 -02 PENH GUM = .' PLAN REVIEW /ROUTING SLIP AJA Fire Prevention Structural Incomplete Planning Division Permit Coordinator DUE DATE: 07 -23 -09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required U REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 08-20-09 Approved n Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 2 10/10/1996 Until Released Bond $4,000.00 License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SEATTMI038NR SEATTLE MECHANICAL INC CONSTRUCTION CONTRACTOR UNUSED SHEET METAL 8/19/199711/4/2001 ARCHIVED Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 11 LIBERTY NORTHWEST INS CORP BKW1053913555 08/01/2009 08/01/2010 $1,000,000.00 07/21/2009 FEDERAL Untitled Page b I General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name IECS INC UBI No. 601639846 Phone 2064694153 Status ACTIVE Address PO BOX 19252 License No. IECS***044QL Suite /Apt. License Type CONSTRUCTION CONTRACTOR City SEATTLE Effective Date 11/13/1996 State WA Expiration Date 11/20/2010 Zip 981091252 Suspend Date County KING Specialty 1 HTG /VENT /AIR CONDITIONING Business Type Corporation Specialty 2 UNUSED Parent Company Other Associated Licenses Business Owner Information Name HUMPHREY, GEORGE Role Effective Date 01/01/1980 Expiration Date Assignment of Savings Information Insurance Information Page 1 of 2 https://fortress.wa.gov/lni/bbip/Detail.aspx 09/21/2009 SITE PLAN VICINITY MAP SITE & BUILDING STATISTICS BAR JOIST NEW AC CONDENSER MINI SPLIT CONDESER ROOF DETAIL NTS TWO 3/8' BOLTS FOR EACH SLEEPER INTO JOIST BELOW. GATEWAY CORPORATE CENTER NA '' I ii ii .i j• I L_ - 0[MMI�S ... 1 . i' ' uauttaut IiIUCIS u+ i �t -- . __. wuIuull ` : • -== - MU MUM AREA OF WORK ROOF PLAN —BUILDING CODE: UBC 1997 - BUILDING TYPE OF CONSTRUCTION: HI—N SPRINKLERED —OCCUPANCY GROUP: B - BUILDING AREA FIRST FLOOR= 33,039 S.F. SECOND FLOOR= 33,467 S.F. TOTAL= 66,506 S.F. LEGAL DESCRIPTION PARCEL B OF TUKWILA SHORT PLAT 89 -1 —SS, RECORDED UNDER AUDITOR'S FILE #8904120877. 271600 -00- 0070 -06 SCOPE OF WORK PROVIDE AC FOR SERVER ROOMS AND TESTING AREA REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Budding Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Permit No.J Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copt and conditions is acknowledged: REVIEWED FOR CODE COMPLIANC APPROVED JUL 2 8 2009 A 42 City of Tukwila BUILDING DIVISION RECEIVED JUL 22 2009 PERMIT CENTER 4 3 /8'LAG BOLTS INTO SLEEPER TO HOLD DOWN CONDENSER TO SLEEPERS NEW 4X4 WOOD SLEEPER T ROOF ---- Equipment Schedule (OUTDOOR CONDENSING UNITS) Tag __ _:. :.: _ ...._ Make Model CFM Cooling Heating OA CFM V /Ph SOUND R i G UNIT WEIGHT EER Net BTU'S HSPF db's /BEE'S CU -1 MITSUBISHI PUY -M8NHA 14.1 18,000 208/1 46 90 CU -2 CARRIER 38HDR048-3 13 48,000 208/1 61 278 CU -3 SANYO CH1872 16 17,500 20,400 10 208/1 52 97 Equipment Schedule (INDOOR UNITS) Tag Make ± Model CFM Cooling SEER Heating OA CFM V /Ph sour. w�►im UNIT WEIGHT �� Net BTU'S HSPF db's FC-1 MITSUBISHI PKA- A18GAL 380 14,1 18,000 208/1 43 35 FC-2 CARRIER 48TMD007 1,200 13 48,000 208/1 62 151 FC-3 SANYO KHS1872 524 16 17,600 20,500 7.7 208/1 41 26.5 CU 2,FC -1 PR_OVI_DED WITH 7 DAY PROGRAMMABLE THERMOSTAT FC- 2,CU -2 DOES NOT PROVIDE PRIMARY COOLING. INTERLOCKED WITH EXISTING BOILING HVAC SYSTEM _ TO _ PROVIDE?2ND STAGE COOLIN HVAC FLOOR PLA\ SCALE 1/4"=1' SERVER ROOM LEGEND NEW DOOR EXISTING DOOR SUPPLY AIR RETURN AIR SUPPLY AIR SWITCH EXISTING WALL J -BOX FOR POWER AND /OR PHONE ILLUMINATED EXIT SIGN W/ PATHWAY LIGHTING 2' X 4' EXISTING 3 -11IBE FLUORESCENT (88 WATTS) 2' X 4' NEW OR RELOCATED 2 -TUBE FLUORESCENT (66 WATTS) 2' X 4' NEW OR RELOCATED 3 -111BE FLUORESCENT (66 WATTS) 2' X 4' EXISTING 2 -TUBE FLUORESCENT TO REMAIN (66 WATTS) 2' X 2' NEW OR RELOCATED 2 -TUBE FLUORESCENT (66 WATTS), 2' X 4' EXISTING 3 -TUBE FLUORESCENT TO BE REMOVED AND STORED OR REUSED EXISTING NEW DEDICATED EL EMERGANCE PATHWAY LIGHTING, ADD BATTERY BACK UP TO NEW /EXISTING LIGHTS SYSTEM DESCRIPTION PROVIDE TWO NEW 1 % TON DUCTLESS SPLIT SYSTEM A/C UNITS FOR 2 SERVER ROOMS. PROVIDE ONE NEW 4 TON DUCTLESS SPLIT SYSTEM A/C UNIT FOR TESTING AREA. THE 4 TON UNIT TO PROVIDE COOLING ONLY WHEN THE EXISTING HVAC SYSTEM IS INCAPBLE OF KEEPING SPACE TEMPATURE BELOW A SETPOINT OF 75 DEGREES. OUTSIDE AIR AND ECONOMIZER FUNTIONS WILL BE PROVIDE BY EXISTING BUILDING HVAC SYSTEM. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 8 2009 City of Tukwila BUILDING DIVISION RECEIVED JUL 22 2009 PERMIT CENTER 1 0 O) CO N O) O) • ro 0) 0) to in 10 w z 0 z (1) Z O Q Z0 f- Q w o. � OO < O) U, I 0 U