HomeMy WebLinkAboutPermit M09-095 - ACURA OF TUKWILAACURA OF TUKWILA
301 BAKER BL
EXPIRED
02 -09 -10
M09 -095
Parcel No.: 0223100075
Address:
Suite No:
doc: IMC -10/06
301 BAKER BL TUKW
Tenant:
Name: ACURA OF TUKWILA
Address: 301 BAKER BL , TUKWILA WA
Owner:
Name: OB FIFE PROPERTY II L L C
Address: PO BOX 726 , BELLEVUE WA
Contact Person:
Name: SHANNON BUCKINGHAM
Address: 5108 D ST NW , AUBURN WA
DESCRIPTION OF WORK:
REPLACE EXISTING ROOFTOP UNIT LIKE FOR LIKE
Value of Mechanical: $11,000.00
Type of Fire Protection:
City' Tukwila
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat /Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
Contractor:
Name: EMERALD AIRE INC.
Address: 22043 68TH AVENUE SOUTH , KENT, WA
Contractor License No: EMERAAI055BL
MECHANICAL PERMIT
EQUIPMENT TYPE AND QUANTITY
0
0
0
0
0
0
1
0
0
0
0
0
0
0
* *continued on next page **
M09 -095
Permit Number:
Issue Date:
Permit Expires On:
Phone:
Phone: 253 872 -5665
Phone: 206 872 -5665
Expiration Date: 04/01/2011
M09 -095
08/13/2009
02/09/2010
Fees Collected: $303.31
International Mechanical Code Edition: 2006
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment 0
Printed: 08 -13 -2009
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
Signature:
Print Name:
doc: IMC -10!06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
ex
wi
Permit Number: M09 -095
Issue Date: 08/13/2009
Permit Expires On: 02/09/2010
ed this permit and know the same to be true and correct. All provisions of law and ordinances
, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the p formance of work. I am authorized to sign and obtain this mechanical permit.
Date: V l`�Y01
Date:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
M09 - 095 Printed: 08 -13 -2009
Parcel No.: 0223100075
Address: 301 BAKER BL TUKW
Suite No:
Tenant: ACURA OF TUKWILA
1: ** *BUILDING DEPARTMENT CONDmONS * **
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Permit Number: M09 -095
Status: ISSUED
Applied Date: 07/30/2009
Issue Date: 08/13/2009
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: Readily accessible access to roof mounted equipment is required.
6: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
8: Manufacturers installation instructions shall be available on the job site at the time of inspection.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
12: ** *FIRE DEPARTMENT CONDITIONS * **
13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned
in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051)
15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
doc: Cond -10/06
M09 -095 Printed: 08 -13 -2009
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
•
air- moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051)
17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051)
18: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051)
19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Cond -10/06
* *continued on next page **
M09 -095 Printed: 08 -13 -2009
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature:
Print Name:
doc: Cond -10106
r Y) O( n .�i/')
M09 -095
Date:
ordinances governing
or local laws regulating
Printed: 08 -13 -2009
SITE LOCATION
Site Address: ...3c)x TXLQX 7-Awi
Tenant Name: lq e,afe? ■Se.G47frtri
Property Owners Name: 00 iptel //"DiX/42i4) Z. La
Mailing Address: p 0 93 7.01o,
MECHANICAL CONTRACTOR INFORMATION
Company Name: tnereaid
Company Name:
Mailing Address:
Company Name:
Mailing Address:
Contact Pers..
E- • Address:
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
n
Mailing Address: 5/OR 2D s# Aict
Contact PersonZha OrZ n
E-Mail Address:64/3 r) onb grne cnr
Contractor Registration Number: ,6777 CgAgla / 573
Contact Perso
E-Mail Address:
H: \ApplicationsWoms-Applications On Line \2009 ApplicationMI-2009 - Mechanical Permit Application.doc
Revised! 1-2009
bh
Mechanical Permit No.
Project No. "
(For office use only).
King Co Assessor's Tax No.: 0 273 ) pool r
Suite Number: Floor:
New Tenant: 0 Yes
14- 6 3 t 7
City
State
CONTACT PERSON =vi
we coniierwhA tiaily:to
:r
Name:, _ Day Telephone: 62153 S2:266'or
Mailing Address: Sit S D /IQ aaharn 'six/
City State Zip
E-Mail Address Sheinno on -etniratoclaii . tom Fax Number: OM 'SW S 7 5'7
Ojihirn 101- gszoi
City State Zip
Day Telephone:Acf)S7025(acpc
Fax Number: 0, "7/
Expiration Date: 9 /
" All mUst.beTwet staMped by Architect of Record - •
• 'r - - I • '4k: - s •
State
State
Zip
Zip
City
Day Telephone:
Fax Number:
ENGINEER OF RECORD must be wet stamped by Engineer of Record ,
Zip
City
Day Telephone:
Fax Number:
Page I of 2
Unit Type:
Qty
Unit Type :: '
Qty
Unit Type:
Qty
•Boiler /Comp ressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000
BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000
BTU
Appliance Vent
Hood and Duct
Emergency Generator
50+ HP /1,750,000 BTU
Repair or addition to
Heat/Refrig/Cooling System
Incinerator — Domestic
Other Mechanical
Equipment
Air Handling Unit <10,000
CFM
1 -
Incinerator — Comm/Ind
�r r
Valuation of Project (contractor's bid price): $ ) l O V O
Scope of Work (please provide detailed information):
Use: Residential: New
Commercial: New ❑ Replacement ......
Fuel Type: Electric A Gas ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN d' OR A TTT RIZED AGENT:
Signature:
Print Name: Ziha P) l) f) th /n f /ULM
Mailing Address: . SJn k (7) Sfi VPO
Date Application Expires: otil//
Pi 40
Date Application Accepted:
Replacement
H:1ApplicationslForms •Applications On Line12009 Applications11 -2009 - Mechanical Permit Application.doc
Revised: 1 -2009
bh
Date: / //i5 !
Day Telephone:__ 3 870)1-- "
„btu()
City S tate Zip
Staff Initials:
ge2of2
Parcel No.: 0223100075
Address: 301 BAKER BL TUKW
Suite No:
Applicant: ACURA OF TUKWILA
Receipt No.: R09 -01269
Initials:
User ID:
Payee:
JEM
1165
ACCOUNT ITEM LIST:
Description
EMERALD AIRE INC
MECHANICAL - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 1395 242.65
Authorization No.
RECEIPT
Account Code Current Pmts
000.322.102.00.0 242.65
Total: $242.65
•
Permit Number: M09 -095
Status: APPROVED
Applied Date: 07/30/2009
Issue Date:
Payment Amount: $242.65
Payment Date: 08/13/2009 12:01 PM
Balance: $0.00
PAYMENT
RECEIVED
doc: Receiot -06 Printed: 08 -13 -2009
Copy Reprinted on 07 -30 -2009 at 14:39:09 07/30/2009
RECEIPT NO: R09 -01195
Payment Date: 07/30/2009
User ID: 1165 Total Payment: 144.66
Initials: JEM
Payee: EMERALD AIRE INC.
SET ID: S000001271 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member
EL09 -0457
M09 -095
TOTAL:
Amount
84.00
60.66
84.00
TRANSACTION LIST:
Type Method Description Amount
Payment Check 1388 144.66
TOTAL: 144.66
ACCOUNT ITEM LIST:
Description
ELECTRICAL PERMIT - NONR
PLAN CHECK - NONRES
Ci/ of Tukwila.
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: //www. ci. tukwila. wa. us
SET RECEIPT
•
Account Code Current Pmts
000.322.101.00.0
000/345.830
84.00
60.66
TOTAL: 144.66
PAYMENT
RECEIVED
Part Number
Description
Quantity
48TME007---6
Rooftop Unit
1
Accessories
0688 - 0100 -9P920
Vertical Economizer with solid -state controller
1
Project: - Untitled2
Prepared By:
Unit Report For R -22
07/06/2009
08:26AM
Unit Parameters
Unit Model: 48TME007 - - -6
Unit Size: 007 (6 Tons)
Volts- Phase - Hertz: 460 -3 -60
Heating Type: Gas
Duct Cfg: Vertical Supply / Vertical Return
Heating Capacity:
Medium Heat
Lines and Filters
Gas Line Size: 1/2 in.
Condensate Drain Line Size 3/4 in.
Return Air Filter Type: Throwaway
Return Air Filter Quantity: 2
Return Air Filter Size: 16x25x2
Unit Configuration
Standard Electro- Mechanical Controls
Standard Motor & Drive
Al /Cu Cond and Evap
FILE COPY
Permit No., MAYA — OqC
Plan review approval is subject to errors and omissions.
Approval of construction tion documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Re Copy and ►, ons is acknowledged
By .
Date.
A li
City Of lbkwila
BUILDING DIVISION
Packaged Rooftop Builder 1.19i
Dimensions (ft. in.) & Weight (lb.)'*'
Unit Length: 6' 2"
Unit Width: 3' 9"
Unit Height 2' 9"
Base Unit Weight: 665 lb
**" Weights and Dimensions are approximate. Weight does not include roof
curbs, unit packaging, field installed accessories or factory
installed options. Approximate dimensions are provided primarily for
shipping purposes For exact dimensions and weights, refer to appropriate
product data catalog.
SEPARATE PERMIT
REQUIRED FOR:
CI Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
BUiLpipp pyISIov j
Warranty Information
First Year - Parts Only (Standard)
No optional warranties were selected.
NOTE: Please see Warranty Catalog 500 -089 for explanation of policies and ordering methods.
Ordering Information
CODE CO W jwpu
APPROVED
AUG 0 6 1009
City
BUILDING
f ila
!Minty
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
CITYOF
JUL ; 0 2009
PERMIT CENTER
° 01 5
Page 1 of 6
Project: - Untitled2
Prepared By:
Certified Drawing for R -22
07/06/2009
08:26AM
Packaged Rooftop Builder 1.19i
Page 2 of 6
UNITED •
.. ..,.
CARR CARR I ER TES "'--
IR
` . " . . .. p ie.... ..
; [I. : e N M MOOe
.. � �ff
I. I
-
•,in1 , IV19t • Ct@1fn
UNIT
48HJ.004
STD. UNIT
WEIGHT
ZCONOMIRER♦
WEIGHT '
ECONOMISER.
W/P.E WEIGHT
(A)
CORNER WEIGHT
03)
CORNER WEIGHT
(C)
CORNER WEIGHT
(D)
CORNER WEIGHT
'J"
BOTTOM POWER CHART,
THESE HOLES REO'D FOR USE
WITH ACCESSORY PACKAGES -
2A01, 3A01, CR 4A01
CONNECTION SIZES
u•(
06/19/2003
A 1 3/8' DIA. [351 FIELD POWER SUPPLY MOLE
LBS.
530
KG.
240
LBS.
50
KG.
22.7
LBS.
90
KG,
40.9
LBS.
127
KG.
57.6
LBS.
122
KG.
55.3
LBS.
138
KG.
62.6
LBS.
143
KG.
64.9
FT. -IN.
2' -9 5/16
MM
846.5
B 2' DIA. 1511 POWER SUPPLY KNOCK-OUT
CRBTMPWROOIA01,
C 13/4' DIA. T44] CHANGING PORT HOLE
48MJ .005
540
245
129
58.5
124
56.2
141
64.0
146
66.2
THREADED
CODUIT SIZE
WIRE
USE
MOLE
5IZES D HOLE
SIZES
0 7/0' DIA. FIELD CONTROL WIRING HOLE
48HJ.006
560
254
134
60.8
129
58.5
146
66.2
151
68.5
1/2
1/2"
3/4' (001,003)
1 1/4" [002,004)P0WER.
(003) 1/2 FPT
(004) 3 /4'FPT
ACC.
240
POWER.
GAS
GAS
7/8 "122.21
7/8"[22.2]
1 1/8 "[28.4)
1 3/4'[44.41
1 1/4 "[31.87
15/8 "[41.31
E 3/4' 14 NPT CONDENSATE DRAIN
4804.007
8MJ.007
615
635
279
288
T
147
152
66.7
68.9
142
147
64.4
66.7
160
165
72.6
74.8
166
171
75.3
77.5,
F 1/2' 14 N[ COMECTION
j g
C
O
to
`"
z
- •'
-, K
p
c2
11
y
o
I
N_
o
07/19/2002 REV G 48HJx004, 005, 006, 007 / 48TM ■007 SOHJ501141 H
SINGLE ZONE ELECTRIC COOLING WITH GAS HEAT
3 " -5 5/16'
1050
G 2 1/2 DIA. I POWER SUPPLY KNOCK -OUT
NOTES,
1. DIMENSIONS IN ] ARE IN MILLIMETERS.
2. CENTER OF GRAVITY.
3. a DIRECTION OF AIR FLOW. FILTER
4. ON VERTICAL DISCHARGE UNITS, DUCTWORK TO BE ATTACHED
TO ACCESSORY ROOF CURB ONLY. FOR HORIZONTAL DISCHARGE
UNITS FIELD SUPPLIED FLANGES SHOULD BE ATTACHED TO
HORIZONTAL DISCHARGE OPENINGS. AND ALL DUCTWORK SHOULD
BE ATTACHED TO THE FLANGES.
- _ OUTSIDE AIR
l
�'
is
- SELECT El HER 3/4" OR I I/4
FOR POWER, DEPENDING ON WIRE SIZE.
+ l
S I I I , F ECONOMISER 84 + AND ,JI
REAR POWER EXHAUST J
/ECONOMIZER ACCESS PANEL I
0 -4 1/2' FILTER ACCESS PANEL
°-[ 141 (DISPOSABLE FILTERS)
I�
CONDENSER COIL
ECONOM IfER. HOO
CORNER -B-
I' -5 1/4"
BLOCKOFF
[438] PANEL
FOR ECONOMISER.
0 D
CORNER "A"
5. MINIMUM CLEARANCE (LOCAL CODES OR JURISDICTION MAY
PREVAIL).
2 ' 7 1/2"
[8001
I 3/4'
u[45]
V I E W 5-5
RIGHT SIDE
o. BETWEEN UNIT, FLUE SIDE AND COMBUSTIBLE SURFACES
36 IN., 18 IN. WHEN USING ACCESSORY FLUE DISCHARGE DEFLTR,
b. BOTTOM OF UNIT TO COMBUSTIBLE SURFACES (WHEN NOT USING
CURB) 1 INCH.
BOTTOM OF BASE RAIL TO COMBUSTIBLE SURFACES (WHEN NOT
USING CURB) 0 INCHES.
c. CONDENSER COIL, FOR PROPER AIR FLOW, 36 INCHES
ONE SIDE, 12 INCHES THE OTHER. THE SIDE GETTING THE
GREATER CLEARANCE IS OPTIONAL.
0. OVERHEAD, 60 INCHES TO ASSURE PROPER CONDENSER FAN
L
SIDE
/ ///
I 2' 1 I1 /16"---1
/ / l
..0"
e
I
) 0' -10
I [27
I
[65
C
EVAPORATOR I
COIL RETURN AIR OPENING I
I VERTICAL
1S/16"
7 8]
/ / / //4 RETURN AIR
O' -S 3 /8'
[1371
/
d
OPERATION. 3 9 "
I
H. BETWEEN UNITS. CONTROL BOX SIDE, 42 IN. PER NEC. [1144]
F. BETWEEN UNIT AND UNGROUNDED SURFACES, CONTROL BOX
SIDE 36 IN. PER NEC.
U 2 1/4
[616] /
/ / E
6' -S 3/4- ALT. CONDENSATE
DRAIN OPENING
0' -2 9/16'
[651
g. BETWEEN UNIT AND BLOCK OR CONCRETE WALLS AND OTHER
GROUNDED SURFACES, CONTROL BOX SIDE, 42 IN. PER NEC.
H. HORIZONTAL SUPPLY AND RETURN END, 0 INCHES WHEN THE
ALTERNATE CONDENSATE DRAIN IS USED.
6. WITH THE EXCEPTION OF THE CLEARANCE FOR THE CONDENSER
COIL AND COMBUSTION SIDE AS STATED IN NOTE •50, b,
AND
CLEARANCE.
7. MAY BE INSTALLED ON COMBUSTIBLE FLOORS MADE
1
[533]
-9"
/ -
' /
+ 1' J
[147]-
- ) d
IN BASEPAN
�0' -1 15/16
[491
SUPPLY AIR
OPENING
1' -5 3/4" SUPPLY AIR
[451]
1'6 1/2'
[470]
; /
,\ \ t /
0' 1 7/8 % n
[48.0]
0' -3 3/4
[96.0]
b
`'
/ T
VERTICAL
L
}
'
[2901
8
0' -3 5/16-
[99.47
0' -S 7/16' 1' -B 1/4'
[138]
[514]
UNITS
FROM HOOD OR CLASS A, B, OR C ROOF COVERING MATERIAL J
IF SET ON BASE RAIL. J
CORNER D"
8. THE VERTICAL CENTER OF GRAVITY IS 1' -6 "[4571 UP FROM
FROM THE BOTTOM OF THE BASE RAIL.
SEE BOTTOM PO SEE NOTE .B
CHART(ELEC. ONLY)
FRONT
-0 I/16�
- 3/16 CORNER "C'
�` 0' -7 1/4"
2' -II 11/16'
- •
0' -3 1 /I6'
.� ,'-0 7 /16'[11.7]
-
[906 I [ ' [3067
3' -0 . l -
o- 0' _
(01]
1' -5 5 /16
_
[1847
' -l0 13/16" ECONOMISER.
[9141 6' -1 11/16"
W/ POWER EXHAUST
l' -7 3 /1
[407.4]
' -3 13/76" � P - 0'-0 3/8'
0.-3
[101
[439.7]
[274.61
[I D)
[10;
F ILTER ACCESS PANEL
1
IPA
CONDENSER COIL
-
)
I
dI
(971
FACTORY SUPPLIED
B FLUE HOOD
CONTROL BOX /COMPRESSOR/
BURNER ACCESS
PANEL
=
I
I
I
I
I
1 2' -1
RETURN I
AIR [652.5]
_
OPENING I
ZONTAL
7 1
[177 I
I
(DISPOSABLE FILTERS]
1/16
•i
- _
-
INDOOR FAN MOTOR 6
BLOWER ACCESS PANEL
I
- � n
A
1' -4 5/16"
[414.57
,
8
n
BOTTOM
OF UNIT
L J
=
_
p
II
/II
I
p' - 7 /B'
[301.67
I
I
II
SUPPLY AIR \ \ I I
OPENING
I HORIZONTAL II
I
m
D
F
c m ` Y.-
// 1' -6 1/4' [514]
I
i✓ .� `-
�=
- ^ -
4 -0 " -3 5/16"
OUTSIDE AIR
0'- 0 7/8
0' -6 5 /8'
(376.0]]
_I
- - -
•
[22 2]
p [168.2]
•
���
1 1 y ®l
1
_ �/
I■11 m
0 " -4 9/16
[115.8]
- . /-
" (
2' 5 3/B
1 f -FORK TRUCK SLOTS 0' -5 3/4 "�
[746.2]
15616 0' -5 11/16"
( 2
.%/ [658.6] / [144.3]
IDE SUPPLY AIR RETURN AIR BAROMETRIC RELIEF DISCHARGE
RIGHT S I DE E STD. CONDENSATE DRAIN
3' 5 3/16'
TIT [1046] 0 -B 7/1 146]
0 2 9 / LEFT S I DE E O [214] 0' -2 1[57] IA OF OUT
PANEL
(65] FRONT (TYP 8 PLACES)
z
Project: - Untitled2
Prepared By:
Certified Drawing for R -22
07/06/2009
08:26AM
Packaged Rooftop Builder 1.19i
Page 2 of 6
Project: — Untitled2
Prepared By:
Performance Summary For R -22
07/06/2009
08:26AM
Part Number:48TME0O7 - - -6
ARI EER: 10.10
Base Unit Weight 665 lb
Base Unit Dimensions
Unit Length: 73.7 in
Unit Width: 45.0 in
Unit Height 33.3 in
Unit Voltage- Phase - Hertz: 460 -3 -60
Air Discharge Vertical
Fan Drive Type: Belt
Actual Airflow 2250 CFM
Site Altitude: 0 ft
Cooling Performance
Condenser Entering Air DB: 95.0 F
Evaporator Entering Air DB: 80.0 F
Evaporator Entering Air WB: 67.0 F
Entering Air Enthalpy 31.44 BTU /lb
Evaporator Leaving Air DB: 57.3 F
Evaporator Leaving Air WB: 56.3 F
Evaporator Leaving Air Enthalpy: 23.98 BTU /lb
Gross Cooling Capacity 75.50 MBH
Gross Sensible Capacity: 55.05 MBH
Compressor Power Input 5.83 kW
Coil Bypass Factor: 0.080
Heating Performance
Heating Airflow: 2250 CFM
Entering Air Temp: 70.0 F
Leaving Air Temp: 107.9 F
Gas Input Capacity: 115.0 MBH
Gas Heating Capacity 92.00 MBH
Temperature Rise 37.9 F
Supply Fan
External Static Pressure 0.75 in wg
Options / Accessories Static Pressure
EconoMi$erlV / EconoMi$er2: 0.14 in wg
Total External Static: 0.89 in wg
Fan RPM: 1450
Fan Power: 1.84 BHP
Electrical Data
Minimum Voltage* 414
Maximum Voltage 508
Compressor Qty 1
Compressor RLA (ea) 9 5
Compressor LRA (ea) 73
Outdoor Fan Motor Qty 1
Outdoor Fan Motor HP (ea) 0.25
Outdoor Fan FLA (ea): 0.9
Indoor Fan Motor Type: Standard
IFM Max. Continuous BHP: 2.4
Indoor Fan Motor FLA: 2.6
Power Supply MCA: 15.4
Power Supply MOCP, Fuse or HACR, U.S.A.: 20
Min. Unit Disconnect FLA: 15
Packaged Rooftop Builder 1.19i Page 3 of 6
Project: - Untitled2
Prepared By:
Performance Summary For R -22
07/06/2009
08:26AM
Min. Unit Disconnect LRA 90
Electrical Convenience Outlet: None
Acoustics
Sound Rating 80.0 db
Sound Power Levels, db re 10E -12 Watts
Discharge Inlet Outdoor
63 Hz 89.7 88.5 59.1
125 Hz 85.2 82.3 68.9
250 Hz 79.3 70.2 68.7
500 Hz 74.8 66.5 71.9
1000 Hz 71.1 65.7 74.0
2000 Hz 65.7 60.2 68.9
4000 Hz 67.6 56.1 65.7
8000 Hz 63.6 49.5 59.0
A- Weighted 78.0 71.8 76.9
Packaged Rooftop Builder 1.19i Page 4 of 6
Project: — Untitled2
Prepared By:
Performance Summary For R -22
07/06/2009
08:26AM
2.0
1.8
1.6
1.4
1.2
01.0
to
N
a_
00.8
0.6
0.4
0.2
Packaged Rooftop Builder 1.19i
Fan Curve
MENEM
RP MENNE
MEMENE
MIME
M. 'MEL
700 RPM
IMENIEE12'
MMEMPAL
900 RPM
0.0
00 03 06 09 1.2 15 18 2.1 24
Airflow (CFM - thousands)
RPM = 1450 BHP = 1.84 Maximum RPM = 1457 Maximum HP = 2.40
Note: Please contact application engineering for selections outside the shaded region.
SC - System Curve RP - Rated Point
27
30
33
Page 5 of 6
33 15/16"
40 9/16"
Notes:
1. 1.5" ADDED TO OLD CURB O.D
2. MATERIAL 18. ga. GALVANIZED STEEL
3. GASKET PROVIDED WITH CURB
4. INSULATION: 1" 1 1/2 LB DENSITY
25 1/8"
37 7/8"
15 3/4"
RETURN AIR
SUPPLY
AIR
16 11/16"
Attn: Tag:
Approval:
17 air
EXISITING CURB LAYOUT
69 1/8"
54 15/16"
51 15/16"
CURB SHOWN IS CDI STANDARD CONFIGURATION
CDI RESERVES THE RIGHT TO CHANGE LAYOUT
WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A
DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED
PRIOR TO PLACING AN ORDER.
VERIFY EXISTING t.URB OD
VERIFY SUPPLY AND RETURN OPENINGS
'NOTE ANY CHANGES
'CALL WITH ANY QUESTIONS
FAX BACK IF DRAWING IS OK AS IS
D W ENSIONED AND TOLEPENCED PER n1151 Y1 &SM.1 N3
36 3/8"
COI Model Number
1- 4510 -4000
12"
CURB WEIGHT (LDS.)
MCCAW
w.r �I
NO.
REV.
) 2
3
Existing Unit
48 HDTILOT 004-006
48 HDILD 007
APPROVALS
T. COY
REVISIONS
DESCRIPTION
removed Tanga tarn par815 and added d b pwl
CHANGED HEIGHT FROM 16' TO 12'
New Unit
48/50 TF/TM /HIITJIOJ 004-007
48/50 HJIGJ/LJIO.YHM 004 -007
DATE
1/16/06
9560 85TH AVE. N.
D MAPLE GROVE. MN 65369
(7 763)391.851
70 7/8"
70 7/8"
1- 45104000
SCO
Tonnage
3 ton
4 ton
5 ton
6 ton
Supply
P1055ure Drop
0.051
0.092
0.144
0.187
DATE
May-O5
APPRV
Return
Pressure Drop
0.022
0.040
0.062
0.090
1- 4510 -4000
1:114.910 .110,
loon" 1:18 I Tea,: 1 w 1
ECONOMIZER PART NO.S
0688 - 0101 -00920
Economizer with no controls
0688 - 0101 -9J920
Economizer with modulating
adjustable dry bulb controls
0688 -0101 -54920
Economizer with modulating
enthalpy controls
fUll!! TI!
SUBMITTED TO
COMPANY
DRAWN BY M. HARGIS
JOB NAME
EQUIPMENT
NOTES
• Rainhoods are sloped for
water run -off.
• Hardwaredoth over
relief damper.
MicroMetl
FORM NO. 2895 -6P DATE: 1 107
FEATURES;.
• Gear driven dampers eliminate slippage associated with
standard linkage.
• Designed specifically for down discharge applications. Easy
to install. Easy to service.
• Lower static pressure loss through economizer dampers.
• Greater barometric relief capabilities.
• Factory assembled rainhood with aluminum filters in both
outside air and relief hoods.
• Uses filter access door shipped with HVAC unit.
025
0.2
0.05
0
Economizer motor
and harness
Gear driven
dampers
Down Discharge Economizer with
100% Relief Capability for Carrier
48/50TF, TFQ, HJ, HJQ, TM 004 -007
48/50HE 003 -006
Rainhood ships
fully assembled
0688 -0101 Static Pressure Loss
Through Economizer
500 1000 1500 2000
Airflow (cfm)
Economizerincludes
Honeywell W7212
controller capable of
CO2, demand control and
ower exhaust control
2500
3000
Sloped
Outside
air
3000
2500
S
U 2000
1500
a
.5 woo
re
500
0
Part Number:
0688 -0101
0688 -0101 Barometric Relief
•
•
•
•
0 0.05 0.1 0.15 0.2 0.25
Static Pressure (In w.g.)
0.3
Aluminum water
entrainment filters
Access door
shipped with
HVACunit
Relief air
Drive gear
attached to
the motor
Side View
THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT.
MICROMETL CORPORATION • 3035 N. SHADELANDAVENUE, SUITE 300 • INDIANAPOLIS. IN. 46226.1- 800 - 662-4822 ••• MICROMETL WEST • 202 SOUTH 18TH ST. • SPARKS, NV 89431.1- 800884 -4662
• - ,
ii
*
EN GIN EERIN G
TL
Structural Calculations
e'COP'Y
Acura of Seattle - Tukwila
for
Support of Proposed HVAC Unit
July 24, 2009
7 - 24 -
17924 - 140th Avenue NE, Suite 220
Woodinville, WA 98072 -4315
Phone: (425) 814 -8448
Fax (425) 821 -2120
REVIEWED FOR
CODE COMPLIAN CE
A PPROVeo
AUG 0 6 2009
D City of Tukwila
vILDING DIviQtru,
RECEIVED _
CITY OF TUKVIIILA
JUL 3 0 2009
PERMIT CENTER
BTL
ENGINEERING
17924 —140th Avenue NE, Suite 220
Woodinville, WA 98072 -4315
Phone: (425) 814 -8448
Fax: (425) 821 -2120
Calculations
BTL
ENGINEERING
17924 — 140th Avenue NE, Suite 220
Woodinville, WA 98072 -4315
Phone: (425) 814 -8448
Fax: (425) 821 -2120
Gravity Support
t •
-
;;• •
Jul. 24. 2009 9:00AM
810$ STREET NW; AUBURN, WA 96001
VO10E: (154) 9724666 FAX: (269) 8724797
41 aRe.rADT.7teMelreiXT*1117404.nittMa.r...uraumg,:nowars—wrawer.ratuar
11,
, • • ,
-1ViHd
! •
-7?
..1 !O. ;.! .
• '
! I
1 "
I
J654 •
cofz‘
:NOTES:
/el c1.1.4 RV
No. 1623 P. 1
SUBJECT: IL- _,■44, %
DWG 13Y: , PAGE
DATE ,, SCALE:
7.
..•,.
1 I I.
ii - •
i. . 1.. • 1 . I ...1 . . ..
, . I
.. . . ..
:. .
• )416 i .7re 6 .-,, . ;t7 N 4
L i v 1 •4) . i•.1 (4 . "bl'tk . $:
. ,
go
. ELL
..• .•
.7 • • • ••
1
BTL
ENGINEERING
17924 -140th Avenue NE, Snipe 220
Woodinville, WA 98072 -4315
Phone: 425-814-8448
Rue 425-821-2120
Project A C L-4
Project Number. 0 — o 7 Client
Designed By 4 40/Date:
Scale. Page G - 2'
BTL
ENGINEERING
17924 — 140th Avenue NE, Suite 220
Woodinville, WA 98072 -4315
Phone: (425) 814 -8448
Fax (425) 821 -2120
Seismic Support
Acura of Seattle in Tukwila Revision Date: 7/20/2009
09- 257 -03
Occupancy Category: LII- Other Structures
Seismic Use Group: I
IE = 1.00 (Seismic Factor)
/ s = 1.00 (Snow Factor)
I = 1.00 (Wind Factor)
Site Class:
S S = 1422
s, = .0.487. • •
F = 1.00
F„ = 1.51
D
V
Design Spectral Response Acceleration:
S = F
= 1.42
SDS = % SMS
= 0.95
ASCE Table 11.4 -1
ASCE Table 11.4 -2
V
SM1 = F,S1
= 0.74
S01 = % SM1
= 0.49
IBC Table 1604.5
ASCE Table 20.3 -1
Acura of Seattle in Tukwila
09- 257 -03
Seismic Forces
Component Operating Weight: fi =850 " ' lbs
F =
F p need not exceed:
F = 1.6 Sim Ip W
F = 1289 lbs
F p shall not be less than:
F = 0.3 Sps Ip Wp
F = 242 lbs
Dimensions:
x =b50 in
y = o �a► in
z = 30,in
Curb Height = 26. in
Check Uplift:
F = 387 lbs
MOT =
15858 lb -in
ilT /5 555
5Q'"
0.4 ap Sps Wp [1+2 (z/h)]
R I
MRESIST = 19125 lb -in
3i7 j6
z
Curb Height
Revision Date: 7/20/2009
ASCE Eq. 13.3 -1
ASCE Eq. 13.3 -2
ASCE Eq. 13.3 -3
I LI
F.S. = 1.2 =
1.5
NOT O.K.
w /Ll- l5l: f? so-vr0
ey 474C/1)7'
SeE owl 5 -3.
2
Conterminous 48 States
2006 International Building Code
Latitude = 47.4582388889
Longitude = - 122.25436111111
Spectral Response Accelerations Ss and S1
Ss and S1 = Mapped Spectral Acceleration Values
Site Class B- Fa= 1.0,Fv =1.0
Data are based on a 0.05 deg grid spacing
Period Sa
(sec) (g)
0.2 1.422 (Ss, Site Class B)
1.0 0.487 (S1, Site Class B)
BTL
ENGINEERING
17924 — 140th Avenue NE, Suite 220
Woodinville, WA 98072 -4315
Phone: (425) 814 -8448
Fax: (425) 821 -2120
Details
'1
ROOF ,
#14 SCREWS THROUGH CURB ADAPTER
INTO EXISTING CURB. (5) EA. SIDE $
(4) EACH END.
EXISTING CURB
FASTEN R -22 TO ROOF CURB
ADAPTOR W/ IS-GA. STEEL STRAP $
(2) #I2 SCREWS TYP @ (4) CORNERS.
PLUS (I) PER LONG SIDE.
ATTACHMENT DETAIL
SHANNON BUCKINGHAM
5108 D ST NW
AUBURN WA 98001
RE: Permit No. M09 - 095
301 BAKER BL TUKW
Sincerely,
Bill Rambo
Permit Technician
File: Permit File No. M09 -095
Department of Community Development
Jim Haggerton, Mayor
Jack Pace, Director
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of
Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform
Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the
provisions of these codes shall expire by limitation and become null and void if the building or work authorized
by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 02/09/2010.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final
inspection. Each inspection creates a new 180 day period.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is
due to expire. Address your extension request to the Building Official and state your reason(s) for
the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is
determined that your extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 02/09/2010, your permit will
become null and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
-- v,A otitAl,
6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 o Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665
PERMIT COORD COPY if
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M09 -095 DATE: 07 -30 -09
PROJECT NAME: ACURA
SITE ADDRESS: 301 BAKER BL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Issued
DEPARTMENTS:
AW O O
Building Di visi o n
Public Works
Complete
Comments:
REVIEWER'S INITIALS:
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
APPROVALS OR CORRECTIONS:
Documents/routing slip.doc
2 -28 -02
tG 8
Fire Prevention
Structural n
Incomplete n
Planning Division
Permit Coordinator
Not Applicable
DUE DATE: 08-04-09
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route, Structural Review Required ❑ No further Review Required
DATE:
DUE DATE: 08-25-09
Approved I Approved with Conditions , Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: