HomeMy WebLinkAboutPermit M09-095 - ACURA OF TUKWILAACURA OF TUKWILA 301 BAKER BL EXPIRED 02 -09 -10 M09 -095 Parcel No.: 0223100075 Address: Suite No: doc: IMC -10/06 301 BAKER BL TUKW Tenant: Name: ACURA OF TUKWILA Address: 301 BAKER BL , TUKWILA WA Owner: Name: OB FIFE PROPERTY II L L C Address: PO BOX 726 , BELLEVUE WA Contact Person: Name: SHANNON BUCKINGHAM Address: 5108 D ST NW , AUBURN WA DESCRIPTION OF WORK: REPLACE EXISTING ROOFTOP UNIT LIKE FOR LIKE Value of Mechanical: $11,000.00 Type of Fire Protection: City' Tukwila Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Contractor: Name: EMERALD AIRE INC. Address: 22043 68TH AVENUE SOUTH , KENT, WA Contractor License No: EMERAAI055BL MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 1 0 0 0 0 0 0 0 * *continued on next page ** M09 -095 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 872 -5665 Phone: 206 872 -5665 Expiration Date: 04/01/2011 M09 -095 08/13/2009 02/09/2010 Fees Collected: $303.31 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 08 -13 -2009 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Signature: Print Name: doc: IMC -10!06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ex wi Permit Number: M09 -095 Issue Date: 08/13/2009 Permit Expires On: 02/09/2010 ed this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p formance of work. I am authorized to sign and obtain this mechanical permit. Date: V l`�Y01 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 - 095 Printed: 08 -13 -2009 Parcel No.: 0223100075 Address: 301 BAKER BL TUKW Suite No: Tenant: ACURA OF TUKWILA 1: ** *BUILDING DEPARTMENT CONDmONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M09 -095 Status: ISSUED Applied Date: 07/30/2009 Issue Date: 08/13/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the doc: Cond -10/06 M09 -095 Printed: 08 -13 -2009 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • air- moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M09 -095 Printed: 08 -13 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: doc: Cond -10106 r Y) O( n .�i/') M09 -095 Date: ordinances governing or local laws regulating Printed: 08 -13 -2009 SITE LOCATION Site Address: ...3c)x TXLQX 7-Awi Tenant Name: lq e,afe? ■Se.G47frtri Property Owners Name: 00 iptel //"DiX/42i4) Z. La Mailing Address: p 0 93 7.01o, MECHANICAL CONTRACTOR INFORMATION Company Name: tnereaid Company Name: Mailing Address: Company Name: Mailing Address: Contact Pers.. E- • Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** n Mailing Address: 5/OR 2D s# Aict Contact PersonZha OrZ n E-Mail Address:64/3 r) onb grne cnr Contractor Registration Number: ,6777 CgAgla / 573 Contact Perso E-Mail Address: H: \ApplicationsWoms-Applications On Line \2009 ApplicationMI-2009 - Mechanical Permit Application.doc Revised! 1-2009 bh Mechanical Permit No. Project No. " (For office use only). King Co Assessor's Tax No.: 0 273 ) pool r Suite Number: Floor: New Tenant: 0 Yes 14- 6 3 t 7 City State CONTACT PERSON =vi we coniierwhA tiaily:to :r Name:, _ Day Telephone: 62153 S2:266'or Mailing Address: Sit S D /IQ aaharn 'six/ City State Zip E-Mail Address Sheinno on -etniratoclaii . tom Fax Number: OM 'SW S 7 5'7 Ojihirn 101- gszoi City State Zip Day Telephone:Acf)S7025(acpc Fax Number: 0, "7/ Expiration Date: 9 / " All mUst.beTwet staMped by Architect of Record - • • 'r - - I • '4k: - s • State State Zip Zip City Day Telephone: Fax Number: ENGINEER OF RECORD must be wet stamped by Engineer of Record , Zip City Day Telephone: Fax Number: Page I of 2 Unit Type: Qty Unit Type :: ' Qty Unit Type: Qty •Boiler /Comp ressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 - Incinerator — Comm/Ind �r r Valuation of Project (contractor's bid price): $ ) l O V O Scope of Work (please provide detailed information): Use: Residential: New Commercial: New ❑ Replacement ...... Fuel Type: Electric A Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN d' OR A TTT RIZED AGENT: Signature: Print Name: Ziha P) l) f) th /n f /ULM Mailing Address: . SJn k (7) Sfi VPO Date Application Expires: otil// Pi 40 Date Application Accepted: Replacement H:1ApplicationslForms •Applications On Line12009 Applications11 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Date: / //i5 ! Day Telephone:__ 3 870)1-- " „btu() City S tate Zip Staff Initials: ge2of2 Parcel No.: 0223100075 Address: 301 BAKER BL TUKW Suite No: Applicant: ACURA OF TUKWILA Receipt No.: R09 -01269 Initials: User ID: Payee: JEM 1165 ACCOUNT ITEM LIST: Description EMERALD AIRE INC MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1395 242.65 Authorization No. RECEIPT Account Code Current Pmts 000.322.102.00.0 242.65 Total: $242.65 • Permit Number: M09 -095 Status: APPROVED Applied Date: 07/30/2009 Issue Date: Payment Amount: $242.65 Payment Date: 08/13/2009 12:01 PM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 08 -13 -2009 Copy Reprinted on 07 -30 -2009 at 14:39:09 07/30/2009 RECEIPT NO: R09 -01195 Payment Date: 07/30/2009 User ID: 1165 Total Payment: 144.66 Initials: JEM Payee: EMERALD AIRE INC. SET ID: S000001271 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member EL09 -0457 M09 -095 TOTAL: Amount 84.00 60.66 84.00 TRANSACTION LIST: Type Method Description Amount Payment Check 1388 144.66 TOTAL: 144.66 ACCOUNT ITEM LIST: Description ELECTRICAL PERMIT - NONR PLAN CHECK - NONRES Ci/ of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT • Account Code Current Pmts 000.322.101.00.0 000/345.830 84.00 60.66 TOTAL: 144.66 PAYMENT RECEIVED Part Number Description Quantity 48TME007---6 Rooftop Unit 1 Accessories 0688 - 0100 -9P920 Vertical Economizer with solid -state controller 1 Project: - Untitled2 Prepared By: Unit Report For R -22 07/06/2009 08:26AM Unit Parameters Unit Model: 48TME007 - - -6 Unit Size: 007 (6 Tons) Volts- Phase - Hertz: 460 -3 -60 Heating Type: Gas Duct Cfg: Vertical Supply / Vertical Return Heating Capacity: Medium Heat Lines and Filters Gas Line Size: 1/2 in. Condensate Drain Line Size 3/4 in. Return Air Filter Type: Throwaway Return Air Filter Quantity: 2 Return Air Filter Size: 16x25x2 Unit Configuration Standard Electro- Mechanical Controls Standard Motor & Drive Al /Cu Cond and Evap FILE COPY Permit No., MAYA — OqC Plan review approval is subject to errors and omissions. Approval of construction tion documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Re Copy and ►, ons is acknowledged By . Date. A li City Of lbkwila BUILDING DIVISION Packaged Rooftop Builder 1.19i Dimensions (ft. in.) & Weight (lb.)'*' Unit Length: 6' 2" Unit Width: 3' 9" Unit Height 2' 9" Base Unit Weight: 665 lb **" Weights and Dimensions are approximate. Weight does not include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes For exact dimensions and weights, refer to appropriate product data catalog. SEPARATE PERMIT REQUIRED FOR: CI Mechanical Electrical Plumbing Gas Piping City of Tukwila BUiLpipp pyISIov j Warranty Information First Year - Parts Only (Standard) No optional warranties were selected. NOTE: Please see Warranty Catalog 500 -089 for explanation of policies and ordering methods. Ordering Information CODE CO W jwpu APPROVED AUG 0 6 1009 City BUILDING f ila !Minty REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. CITYOF JUL ; 0 2009 PERMIT CENTER ° 01 5 Page 1 of 6 Project: - Untitled2 Prepared By: Certified Drawing for R -22 07/06/2009 08:26AM Packaged Rooftop Builder 1.19i Page 2 of 6 UNITED • .. ..,. CARR CARR I ER TES "'-- IR ` . " . . .. p ie.... .. ; [I. : e N M MOOe .. � �ff I. I - •,in1 , IV19t • Ct@1fn UNIT 48HJ.004 STD. UNIT WEIGHT ZCONOMIRER♦ WEIGHT ' ECONOMISER. W/P.E WEIGHT (A) CORNER WEIGHT 03) CORNER WEIGHT (C) CORNER WEIGHT (D) CORNER WEIGHT 'J" BOTTOM POWER CHART, THESE HOLES REO'D FOR USE WITH ACCESSORY PACKAGES - 2A01, 3A01, CR 4A01 CONNECTION SIZES u•( 06/19/2003 A 1 3/8' DIA. [351 FIELD POWER SUPPLY MOLE LBS. 530 KG. 240 LBS. 50 KG. 22.7 LBS. 90 KG, 40.9 LBS. 127 KG. 57.6 LBS. 122 KG. 55.3 LBS. 138 KG. 62.6 LBS. 143 KG. 64.9 FT. -IN. 2' -9 5/16 MM 846.5 B 2' DIA. 1511 POWER SUPPLY KNOCK-OUT CRBTMPWROOIA01, C 13/4' DIA. T44] CHANGING PORT HOLE 48MJ .005 540 245 129 58.5 124 56.2 141 64.0 146 66.2 THREADED CODUIT SIZE WIRE USE MOLE 5IZES D HOLE SIZES 0 7/0' DIA. FIELD CONTROL WIRING HOLE 48HJ.006 560 254 134 60.8 129 58.5 146 66.2 151 68.5 1/2 1/2" 3/4' (001,003) 1 1/4" [002,004)P0WER. (003) 1/2 FPT (004) 3 /4'FPT ACC. 240 POWER. GAS GAS 7/8 "122.21 7/8"[22.2] 1 1/8 "[28.4) 1 3/4'[44.41 1 1/4 "[31.87 15/8 "[41.31 E 3/4' 14 NPT CONDENSATE DRAIN 4804.007 8MJ.007 615 635 279 288 T 147 152 66.7 68.9 142 147 64.4 66.7 160 165 72.6 74.8 166 171 75.3 77.5, F 1/2' 14 N[ COMECTION j g C O to `" z - •' -, K p c2 11 y o I N_ o 07/19/2002 REV G 48HJx004, 005, 006, 007 / 48TM ■007 SOHJ501141 H SINGLE ZONE ELECTRIC COOLING WITH GAS HEAT 3 " -5 5/16' 1050 G 2 1/2 DIA. I POWER SUPPLY KNOCK -OUT NOTES, 1. DIMENSIONS IN ] ARE IN MILLIMETERS. 2. CENTER OF GRAVITY. 3. a DIRECTION OF AIR FLOW. FILTER 4. ON VERTICAL DISCHARGE UNITS, DUCTWORK TO BE ATTACHED TO ACCESSORY ROOF CURB ONLY. FOR HORIZONTAL DISCHARGE UNITS FIELD SUPPLIED FLANGES SHOULD BE ATTACHED TO HORIZONTAL DISCHARGE OPENINGS. AND ALL DUCTWORK SHOULD BE ATTACHED TO THE FLANGES. - _ OUTSIDE AIR l �' is - SELECT El HER 3/4" OR I I/4 FOR POWER, DEPENDING ON WIRE SIZE. + l S I I I , F ECONOMISER 84 + AND ,JI REAR POWER EXHAUST J /ECONOMIZER ACCESS PANEL I 0 -4 1/2' FILTER ACCESS PANEL °-[ 141 (DISPOSABLE FILTERS) I� CONDENSER COIL ECONOM IfER. HOO CORNER -B- I' -5 1/4" BLOCKOFF [438] PANEL FOR ECONOMISER. 0 D CORNER "A" 5. MINIMUM CLEARANCE (LOCAL CODES OR JURISDICTION MAY PREVAIL). 2 ' 7 1/2" [8001 I 3/4' u[45] V I E W 5-5 RIGHT SIDE o. BETWEEN UNIT, FLUE SIDE AND COMBUSTIBLE SURFACES 36 IN., 18 IN. WHEN USING ACCESSORY FLUE DISCHARGE DEFLTR, b. BOTTOM OF UNIT TO COMBUSTIBLE SURFACES (WHEN NOT USING CURB) 1 INCH. BOTTOM OF BASE RAIL TO COMBUSTIBLE SURFACES (WHEN NOT USING CURB) 0 INCHES. c. CONDENSER COIL, FOR PROPER AIR FLOW, 36 INCHES ONE SIDE, 12 INCHES THE OTHER. THE SIDE GETTING THE GREATER CLEARANCE IS OPTIONAL. 0. OVERHEAD, 60 INCHES TO ASSURE PROPER CONDENSER FAN L SIDE / /// I 2' 1 I1 /16"---1 / / l ..0" e I ) 0' -10 I [27 I [65 C EVAPORATOR I COIL RETURN AIR OPENING I I VERTICAL 1S/16" 7 8] / / / //4 RETURN AIR O' -S 3 /8' [1371 / d OPERATION. 3 9 " I H. BETWEEN UNITS. CONTROL BOX SIDE, 42 IN. PER NEC. [1144] F. BETWEEN UNIT AND UNGROUNDED SURFACES, CONTROL BOX SIDE 36 IN. PER NEC. U 2 1/4 [616] / / / E 6' -S 3/4- ALT. CONDENSATE DRAIN OPENING 0' -2 9/16' [651 g. BETWEEN UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES, CONTROL BOX SIDE, 42 IN. PER NEC. H. HORIZONTAL SUPPLY AND RETURN END, 0 INCHES WHEN THE ALTERNATE CONDENSATE DRAIN IS USED. 6. WITH THE EXCEPTION OF THE CLEARANCE FOR THE CONDENSER COIL AND COMBUSTION SIDE AS STATED IN NOTE •50, b, AND CLEARANCE. 7. MAY BE INSTALLED ON COMBUSTIBLE FLOORS MADE 1 [533] -9" / - ' / + 1' J [147]- - ) d IN BASEPAN �0' -1 15/16 [491 SUPPLY AIR OPENING 1' -5 3/4" SUPPLY AIR [451] 1'6 1/2' [470] ; / ,\ \ t / 0' 1 7/8 % n [48.0] 0' -3 3/4 [96.0] b `' / T VERTICAL L } ' [2901 8 0' -3 5/16- [99.47 0' -S 7/16' 1' -B 1/4' [138] [514] UNITS FROM HOOD OR CLASS A, B, OR C ROOF COVERING MATERIAL J IF SET ON BASE RAIL. J CORNER D" 8. THE VERTICAL CENTER OF GRAVITY IS 1' -6 "[4571 UP FROM FROM THE BOTTOM OF THE BASE RAIL. SEE BOTTOM PO SEE NOTE .B CHART(ELEC. ONLY) FRONT -0 I/16� - 3/16 CORNER "C' �` 0' -7 1/4" 2' -II 11/16' - • 0' -3 1 /I6' .� ,'-0 7 /16'[11.7] - [906 I [ ' [3067 3' -0 . l - o- 0' _ (01] 1' -5 5 /16 _ [1847 ' -l0 13/16" ECONOMISER. [9141 6' -1 11/16" W/ POWER EXHAUST l' -7 3 /1 [407.4] ' -3 13/76" � P - 0'-0 3/8' 0.-3 [101 [439.7] [274.61 [I D) [10; F ILTER ACCESS PANEL 1 IPA CONDENSER COIL - ) I dI (971 FACTORY SUPPLIED B FLUE HOOD CONTROL BOX /COMPRESSOR/ BURNER ACCESS PANEL = I I I I I 1 2' -1 RETURN I AIR [652.5] _ OPENING I ZONTAL 7 1 [177 I I (DISPOSABLE FILTERS] 1/16 •i - _ - INDOOR FAN MOTOR 6 BLOWER ACCESS PANEL I - � n A 1' -4 5/16" [414.57 , 8 n BOTTOM OF UNIT L J = _ p II /II I p' - 7 /B' [301.67 I I II SUPPLY AIR \ \ I I OPENING I HORIZONTAL II I m D F c m ` Y.- // 1' -6 1/4' [514] I i✓ .� `- �= - ^ - 4 -0 " -3 5/16" OUTSIDE AIR 0'- 0 7/8 0' -6 5 /8' (376.0]] _I - - - • [22 2] p [168.2] • ��� 1 1 y ®l 1 _ �/ I■11 m 0 " -4 9/16 [115.8] - . /- " ( 2' 5 3/B 1 f -FORK TRUCK SLOTS 0' -5 3/4 "� [746.2] 15616 0' -5 11/16" ( 2 .%/ [658.6] / [144.3] IDE SUPPLY AIR RETURN AIR BAROMETRIC RELIEF DISCHARGE RIGHT S I DE E STD. CONDENSATE DRAIN 3' 5 3/16' TIT [1046] 0 -B 7/1 146] 0 2 9 / LEFT S I DE E O [214] 0' -2 1[57] IA OF OUT PANEL (65] FRONT (TYP 8 PLACES) z Project: - Untitled2 Prepared By: Certified Drawing for R -22 07/06/2009 08:26AM Packaged Rooftop Builder 1.19i Page 2 of 6 Project: — Untitled2 Prepared By: Performance Summary For R -22 07/06/2009 08:26AM Part Number:48TME0O7 - - -6 ARI EER: 10.10 Base Unit Weight 665 lb Base Unit Dimensions Unit Length: 73.7 in Unit Width: 45.0 in Unit Height 33.3 in Unit Voltage- Phase - Hertz: 460 -3 -60 Air Discharge Vertical Fan Drive Type: Belt Actual Airflow 2250 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy 31.44 BTU /lb Evaporator Leaving Air DB: 57.3 F Evaporator Leaving Air WB: 56.3 F Evaporator Leaving Air Enthalpy: 23.98 BTU /lb Gross Cooling Capacity 75.50 MBH Gross Sensible Capacity: 55.05 MBH Compressor Power Input 5.83 kW Coil Bypass Factor: 0.080 Heating Performance Heating Airflow: 2250 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 107.9 F Gas Input Capacity: 115.0 MBH Gas Heating Capacity 92.00 MBH Temperature Rise 37.9 F Supply Fan External Static Pressure 0.75 in wg Options / Accessories Static Pressure EconoMi$erlV / EconoMi$er2: 0.14 in wg Total External Static: 0.89 in wg Fan RPM: 1450 Fan Power: 1.84 BHP Electrical Data Minimum Voltage* 414 Maximum Voltage 508 Compressor Qty 1 Compressor RLA (ea) 9 5 Compressor LRA (ea) 73 Outdoor Fan Motor Qty 1 Outdoor Fan Motor HP (ea) 0.25 Outdoor Fan FLA (ea): 0.9 Indoor Fan Motor Type: Standard IFM Max. Continuous BHP: 2.4 Indoor Fan Motor FLA: 2.6 Power Supply MCA: 15.4 Power Supply MOCP, Fuse or HACR, U.S.A.: 20 Min. Unit Disconnect FLA: 15 Packaged Rooftop Builder 1.19i Page 3 of 6 Project: - Untitled2 Prepared By: Performance Summary For R -22 07/06/2009 08:26AM Min. Unit Disconnect LRA 90 Electrical Convenience Outlet: None Acoustics Sound Rating 80.0 db Sound Power Levels, db re 10E -12 Watts Discharge Inlet Outdoor 63 Hz 89.7 88.5 59.1 125 Hz 85.2 82.3 68.9 250 Hz 79.3 70.2 68.7 500 Hz 74.8 66.5 71.9 1000 Hz 71.1 65.7 74.0 2000 Hz 65.7 60.2 68.9 4000 Hz 67.6 56.1 65.7 8000 Hz 63.6 49.5 59.0 A- Weighted 78.0 71.8 76.9 Packaged Rooftop Builder 1.19i Page 4 of 6 Project: — Untitled2 Prepared By: Performance Summary For R -22 07/06/2009 08:26AM 2.0 1.8 1.6 1.4 1.2 01.0 to N a_ 00.8 0.6 0.4 0.2 Packaged Rooftop Builder 1.19i Fan Curve MENEM RP MENNE MEMENE MIME M. 'MEL 700 RPM IMENIEE12' MMEMPAL 900 RPM 0.0 00 03 06 09 1.2 15 18 2.1 24 Airflow (CFM - thousands) RPM = 1450 BHP = 1.84 Maximum RPM = 1457 Maximum HP = 2.40 Note: Please contact application engineering for selections outside the shaded region. SC - System Curve RP - Rated Point 27 30 33 Page 5 of 6 33 15/16" 40 9/16" Notes: 1. 1.5" ADDED TO OLD CURB O.D 2. MATERIAL 18. ga. GALVANIZED STEEL 3. GASKET PROVIDED WITH CURB 4. INSULATION: 1" 1 1/2 LB DENSITY 25 1/8" 37 7/8" 15 3/4" RETURN AIR SUPPLY AIR 16 11/16" Attn: Tag: Approval: 17 air EXISITING CURB LAYOUT 69 1/8" 54 15/16" 51 15/16" CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. VERIFY EXISTING t.URB OD VERIFY SUPPLY AND RETURN OPENINGS 'NOTE ANY CHANGES 'CALL WITH ANY QUESTIONS FAX BACK IF DRAWING IS OK AS IS D W ENSIONED AND TOLEPENCED PER n1151 Y1 &SM.1 N3 36 3/8" COI Model Number 1- 4510 -4000 12" CURB WEIGHT (LDS.) MCCAW w.r �I NO. REV. ) 2 3 Existing Unit 48 HDTILOT 004-006 48 HDILD 007 APPROVALS T. COY REVISIONS DESCRIPTION removed Tanga tarn par815 and added d b pwl CHANGED HEIGHT FROM 16' TO 12' New Unit 48/50 TF/TM /HIITJIOJ 004-007 48/50 HJIGJ/LJIO.YHM 004 -007 DATE 1/16/06 9560 85TH AVE. N. D MAPLE GROVE. MN 65369 (7 763)391.851 70 7/8" 70 7/8" 1- 45104000 SCO Tonnage 3 ton 4 ton 5 ton 6 ton Supply P1055ure Drop 0.051 0.092 0.144 0.187 DATE May-O5 APPRV Return Pressure Drop 0.022 0.040 0.062 0.090 1- 4510 -4000 1:114.910 .110, loon" 1:18 I Tea,: 1 w 1 ECONOMIZER PART NO.S 0688 - 0101 -00920 Economizer with no controls 0688 - 0101 -9J920 Economizer with modulating adjustable dry bulb controls 0688 -0101 -54920 Economizer with modulating enthalpy controls fUll!! TI! SUBMITTED TO COMPANY DRAWN BY M. HARGIS JOB NAME EQUIPMENT NOTES • Rainhoods are sloped for water run -off. • Hardwaredoth over relief damper. MicroMetl FORM NO. 2895 -6P DATE: 1 107 FEATURES;. • Gear driven dampers eliminate slippage associated with standard linkage. • Designed specifically for down discharge applications. Easy to install. Easy to service. • Lower static pressure loss through economizer dampers. • Greater barometric relief capabilities. • Factory assembled rainhood with aluminum filters in both outside air and relief hoods. • Uses filter access door shipped with HVAC unit. 025 0.2 0.05 0 Economizer motor and harness Gear driven dampers Down Discharge Economizer with 100% Relief Capability for Carrier 48/50TF, TFQ, HJ, HJQ, TM 004 -007 48/50HE 003 -006 Rainhood ships fully assembled 0688 -0101 Static Pressure Loss Through Economizer 500 1000 1500 2000 Airflow (cfm) Economizerincludes Honeywell W7212 controller capable of CO2, demand control and ower exhaust control 2500 3000 Sloped Outside air 3000 2500 S U 2000 1500 a .5 woo re 500 0 Part Number: 0688 -0101 0688 -0101 Barometric Relief • • • • 0 0.05 0.1 0.15 0.2 0.25 Static Pressure (In w.g.) 0.3 Aluminum water entrainment filters Access door shipped with HVACunit Relief air Drive gear attached to the motor Side View THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT. MICROMETL CORPORATION • 3035 N. SHADELANDAVENUE, SUITE 300 • INDIANAPOLIS. IN. 46226.1- 800 - 662-4822 ••• MICROMETL WEST • 202 SOUTH 18TH ST. • SPARKS, NV 89431.1- 800884 -4662 • - , ii * EN GIN EERIN G TL Structural Calculations e'COP'Y Acura of Seattle - Tukwila for Support of Proposed HVAC Unit July 24, 2009 7 - 24 - 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax (425) 821 -2120 REVIEWED FOR CODE COMPLIAN CE A PPROVeo AUG 0 6 2009 D City of Tukwila vILDING DIviQtru, RECEIVED _ CITY OF TUKVIIILA JUL 3 0 2009 PERMIT CENTER BTL ENGINEERING 17924 —140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 Calculations BTL ENGINEERING 17924 — 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 Gravity Support t • - ;;• • Jul. 24. 2009 9:00AM 810$ STREET NW; AUBURN, WA 96001 VO10E: (154) 9724666 FAX: (269) 8724797 41 aRe.rADT.7teMelreiXT*1117404.nittMa.r...uraumg,:nowars—wrawer.ratuar 11, , • • , -1ViHd ! • -7? ..1 !O. ;.! . • ' ! I 1 " I J654 • cofz‘ :NOTES: /el c1.1.4 RV No. 1623 P. 1 SUBJECT: IL- _,■44, % DWG 13Y: , PAGE DATE ,, SCALE: 7. ..•,. 1 I I. ii - • i. . 1.. • 1 . I ...1 . . .. , . I .. . . .. :. . • )416 i .7re 6 .-,, . ;t7 N 4 L i v 1 •4) . i•.1 (4 . "bl'tk . $: . , go . ELL ..• .• .7 • • • •• 1 BTL ENGINEERING 17924 -140th Avenue NE, Snipe 220 Woodinville, WA 98072 -4315 Phone: 425-814-8448 Rue 425-821-2120 Project A C L-4 Project Number. 0 — o 7 Client Designed By 4 40/Date: Scale. Page G - 2' BTL ENGINEERING 17924 — 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax (425) 821 -2120 Seismic Support Acura of Seattle in Tukwila Revision Date: 7/20/2009 09- 257 -03 Occupancy Category: LII- Other Structures Seismic Use Group: I IE = 1.00 (Seismic Factor) / s = 1.00 (Snow Factor) I = 1.00 (Wind Factor) Site Class: S S = 1422 s, = .0.487. • • F = 1.00 F„ = 1.51 D V Design Spectral Response Acceleration: S = F = 1.42 SDS = % SMS = 0.95 ASCE Table 11.4 -1 ASCE Table 11.4 -2 V SM1 = F,S1 = 0.74 S01 = % SM1 = 0.49 IBC Table 1604.5 ASCE Table 20.3 -1 Acura of Seattle in Tukwila 09- 257 -03 Seismic Forces Component Operating Weight: fi =850 " ' lbs F = F p need not exceed: F = 1.6 Sim Ip W F = 1289 lbs F p shall not be less than: F = 0.3 Sps Ip Wp F = 242 lbs Dimensions: x =b50 in y = o �a► in z = 30,in Curb Height = 26. in Check Uplift: F = 387 lbs MOT = 15858 lb -in ilT /5 555 5Q'" 0.4 ap Sps Wp [1+2 (z/h)] R I MRESIST = 19125 lb -in 3i7 j6 z Curb Height Revision Date: 7/20/2009 ASCE Eq. 13.3 -1 ASCE Eq. 13.3 -2 ASCE Eq. 13.3 -3 I LI F.S. = 1.2 = 1.5 NOT O.K. w /Ll- l5l: f? so-vr0 ey 474C/1)7' SeE owl 5 -3. 2 Conterminous 48 States 2006 International Building Code Latitude = 47.4582388889 Longitude = - 122.25436111111 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B- Fa= 1.0,Fv =1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 1.422 (Ss, Site Class B) 1.0 0.487 (S1, Site Class B) BTL ENGINEERING 17924 — 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 Details '1 ROOF , #14 SCREWS THROUGH CURB ADAPTER INTO EXISTING CURB. (5) EA. SIDE $ (4) EACH END. EXISTING CURB FASTEN R -22 TO ROOF CURB ADAPTOR W/ IS-GA. STEEL STRAP $ (2) #I2 SCREWS TYP @ (4) CORNERS. PLUS (I) PER LONG SIDE. ATTACHMENT DETAIL SHANNON BUCKINGHAM 5108 D ST NW AUBURN WA 98001 RE: Permit No. M09 - 095 301 BAKER BL TUKW Sincerely, Bill Rambo Permit Technician File: Permit File No. M09 -095 Department of Community Development Jim Haggerton, Mayor Jack Pace, Director Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 02/09/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 02/09/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. -- v,A otitAl, 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 o Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 PERMIT COORD COPY if PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M09 -095 DATE: 07 -30 -09 PROJECT NAME: ACURA SITE ADDRESS: 301 BAKER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: AW O O Building Di visi o n Public Works Complete Comments: REVIEWER'S INITIALS: DETERMINATION OF COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 tG 8 Fire Prevention Structural n Incomplete n Planning Division Permit Coordinator Not Applicable DUE DATE: 08-04-09 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route, Structural Review Required ❑ No further Review Required DATE: DUE DATE: 08-25-09 Approved I Approved with Conditions , Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: