Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M09-096 - NC MACHINERY
NC MACHINERY 17900 WEST VALLEY HY M09 -096 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: 3623049011 17900 WEST VALLEY HY TUKW HARNISH GROUP INC PO BOX 3562 , SEATTLE WA Contact Person: Name: KRIS JOHANSON Address: 7717 DETROIT AV SW , SEATTLE WA Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU DESCRIPTION OF WORK: REMOVE EXISTING AND REPLACE WITH NEW 5 -TON ROOF TOP PACKAGE UNIT. INSTALL NEW ADAPTER AND DISCONNECTS. Value of Mechanical: $8,230.00 Type of Fire Protection: doc: IMC -10/06 CityOf Tukwila NC MACHINERY 17000 WEST VALLEY HY , TUKWILA WA Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat /Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 1 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us MECHANICAL PERMIT EOUIPMENT TYPE AND QUANTITY * *continued on next page ** M09 -096 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 407 -2628 Phone: 206 - 768 -4180 Expiration Date: 12/31/2010 M09 -096 08/11/2009 02/07/2010 Fees Collected: $279.11 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 08 -11 -2009 doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us 0 Permit Number: M09 -096 Issue Date: 08/11/2009 Permit Expires On: 02/07/2010 Permit Center Authorized Signature: Date: g - ` i -O l I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o performance o ork. I am authorized to sign and obtain this mechanical permit. Signature: Date: (0C/ t Print Name: ■ S This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -096 Printed: 08 -11 -2009 Parcel No.: 3623049011 Address: 17900 WEST VALLEY HY TUKW Suite No: Tenant: NC MACHINERY 1: ** *BUILDING DEPARTMENT CONDITIONS * ** r • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M09 -096 Status: ISSUED Applied Date: 08/03/2009 Issue Date: 08/11/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Thkwila Building Department (206- 431- 3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Thkwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * * continued on next page ** M09 -096 Printed: 08 -11 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: A doc: Cond -10/06 M09 -096 Date: 0/ i /09 ordinances governing or local laws regulating Printed: 08 -11 -2009 SITE LOCATION King Co Assessor's Tax No.: 3623049011 Site Address: 1400 WEST VALLEY HWY TUKWILA, WA 98124 Suite Number: ROOF Tenant Name: NC MACHINERY - POWER SYSTEMS New Tenant: ❑ Yes J ..No NC MACHINERY Property Owners Name: Mailing Address: 17025 WEST VALLEY HWY CONTACT PERSON - act when yo permit is ready to be issued Name: KRIS JOHANSON Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 Zip E - Mail Address: KRIS.JOHANSON@MACMILLER.COM Company Name: MACDONALD MILLER Mailing Address: 7717 DETROIT AVE SW Contact Person: KRIS JOHANSON E - Mail Address: KRIS.JOHANSON@MACMILLER.COM Contractor Registration Number: MACDOFS980RU Company Name: N/A Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Mechanical Perini Project No. MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** MACDONALD MILLER 7717 DETROIT AVE SW KRIS JOHANSON Contact Person: E -Mail Address: H:\Applications\Forms- Applications On Line\2009 Applications \I-2009 - Mechanical Permit Application.doc Revised: 1.2009 bh TUKWILA City Day Telephone: (206) 407 - 2628 City SEATTLE SEATTLE a e on WA 98124 Zip State State Fax Number: MECHANICAL CONTRACTOR INFORMATION WA 98106 State (206) 407 -2628 City Day Telephone: Fax Number: Expiration Date: 12/31/2010 ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record State Floor: State (206) 407 -2628 Zip Zip City Day Telephone: Fax Number: ENGINEER OF RECORD - All plai amped by list be Engineer of Record WA 98106 Zip City Day Telephone: Fax Number: Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: ` Qty < Boiler/Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 Incinerator — Comm/Ind Valuation of Project (contractor's bid price): $ 8,230 Scope of Work (please provide detailed information): REMOVE EXISTING AND REPLACE WITH NEW 5 TON ROOF TOP PACKAGE UNIT. INSTALL NEW ADAPTER CURD AND DISCONNECTS. GAS PIPING TO BE REUSED - RECONNECTED. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICAT Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O E R OR AUTHORIZED AGENT 1 ., Signature: Print Name: DARLA DOLL Mailing Address: 7717 DETROIT AVE SW Date Application Accepted: dgI 0 3`�1 H: Applications \Forms - Applications On Line\2009 Applications \I -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh Date: 08/03/2009 Day Telephone: (206) 768 4278 SEATTLE City WA 98106 State Staff Initials: Zip Date Application Expires: 0 2) o121 p Receipt No.: R09 - 01210 Initials: User ID: JEM 1165 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2197 279.11 Authorization No. RECEIPT Account Code Current Pmts 000.322.102.00.0 223.29 000/345.830 55.82 Total: $279.11 • Parcel No.: 3623049011 Permit Number: M09 -096 Address: 17900 WEST VALLEY HY TUKW Status: PENDING Suite No: Applied Date: 08/03/2009 Applicant: NC MACHINERY Issue Date: Payment Amount: $279.11 Payment Date: 08/03/2009 12:46 PM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 08 -03 -2009 Project: ) Type of Inpection V Address: 1,000 CON 11 Date Called: Special Instructions: Date Wante k0 �5' O -- � ca::: Requester: Phone No: INSPECTION RECORD Retain a copy with permit 0� ' INSPE NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ? - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3 7 )ikpproved per applicable codes. Corrections required prior to approval. COMMENTS: - ?e ,/ spe pa 60 0 REINSPECTION FEE REQ%IIRED. Pr or to inspection, fee must be at 6300 Southcenter Blvd., S ite 100 Call to schedule reinspection. Re - pt No.: J, a of Date: Project: Ar,T4e 4 '.)Fi'y Type of Ins ection: ti4 Address: /79Q'd Ci/ /1 Date Called: Special Instructions: _Aa Date Wanted: + g-- d y p.m. Requester: Phone No: C -. 'C -4 INSPECTION RECORD etain a copy with permit INSPECTION Na CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. El s Corrections required prior to approval. COMMENTS: InspectorA Da O 'U REINSPECTION FE REQUIRED. nor to inspection, fee must be at 6300 Southcenter B d., Suite 100. Call to schedule reinspection. Ipt No.: 'Date: Project: Ne "90, /Ario7i Type of Inspection: .. 7111i r Nots,4-/k, Dates / Addces,s.yq `/dd /,() ,A9/*C---/ Special Instructions: l Date red. 05 (`• Requester: Phone No 9 _ INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 I X Approved per applicable codes. El Corrections required prior,to approval, COMMENTS: Inspecto /6) I -+ - toffile d/ 6 PERMIT NO. (206)431 -3670 Pke /!I / 47.1-7; _A* "_)// r - 7'd f �vrr D in $61 REINSP CTI N FEE EQUIR 6. Prior to inspection, fee must be pai • at 6300 Southcenter Blvd., Suit 100. Call to schedule reinspection. (Receipt No.: 'Date: A GENERAL SUBMITTAL DATA JOB NAME ARCHITECT ENGINEE R LOCATION SUBMITTED BY APPROVED BY PERFORMANCE AT SPECIFIED CONDITIONS°' (Continued on page 2) MODELS: Unit #1 #2 CAPACITIES — Cooling, Unit #1, Total BTUH Sensible BTUH Unit #2 Total BTUH Sensible BTUH ' Total Cooling BTUH Entering Air, Evaporator, Unit #1 Temp ° F Dry Bulb Temp ° F Wet Bulb Unit #2 Temp ° F Dry Bulb Temp ° F Wet Bulb Indoor Air Flow — Unit #1 CFM Unit #2 CFM Entering Air, Condenser, Temp ° F DB Low Ambient Cooling ° F Outdoor Heating, BTUH Unit #1, 1st Stage Stage Unit #2, 1st Stage 2nd Stage Total Heating BTUH Gas: Natural ; Propane °Installation to be in accordance with Manufacturer's recommendations. CERTIFICATION Dimensions, Specifications, and Performance as indicated on this sheet are certified correct. (Company Name) (Location) BY Date \ CENTRAL AIR CONDITIONING DEPARTMENT, TYLER, TEXAS 75711 ■ 41l ELECTRIC -- R€ IEWED FOR GQD CONiPLIA1dC PROVE G l 0 2009 CIi1l of Tukwila ING DIV DST ROOF TOP AIR CONDITIONING RECEIVE CITY OF TUKIMLA AUG 0 3 2009 I)ERMIT CENTER ACCESSORIES L_ MO BYC-B UNIT SHOWN FILE COPY GAS HEATING /ELECTRIC COOLING 91,000; 112,000; 121,000 BTUH HEATING 38,000; 44,500; 53,500 AND 57,000 BTUH COOLING MODELS BYCO36,048 AND .0608 -E All equipment described herein is eligible for coverage under the General Electric Central Air Conditioning Service Agreement Program. Contact your local General Electric representative for additional information. T MODEL BYC060B116E BYC060B316E BYC060B416E Rated Volts /Ph. /Hz. 230/1/60 200 - 230/3/60 460/3/60 A.R.I. RATINGS (Cooling) ® BTUH Airflow (Indoor) CFM Power, Sys. (KW) & E.E.R. /S.E.E.R. Sound Rating Number 0 57,000 1,860 8.14 -/6.70 20 57,000 2,100 8.14 7.0/- 20 57,000 2,100 8.14 7.0/- 20 A.G.A. RATING (Heating) © ® Input, BTUH Heating Capacity, BTUH Temp. Rise - Min. /Max. ( °F.) Type of Gas (Natural) 1st Stage 120,000 - - ® 2nd Stage 160,000 124,000 45 6 1st Stage 2nd Stage 120,000 160,000 - 124,000 - 45 75 ® 1st Stage 2nd Stage 120,000 160,000 - 124.000 - 45175 ® U POWER CONNECTIONS Branch Cir. Ampacity (Min.) CD Fuse Size - Max. - Recm'd. (Amps) 230V 52 80 - 80 200 -230V 38 60 - 60 460V 19 30 - 30 COMPRESSOR GE Climatuftt Volts /Ph. /Hz. 230/1/60 Unit Nameplate R.L Amps 34 Unit Nameplate L.R. Amps 148 GE ClimatuffnA 200- 230/3/60 23 128 GE Climatuff v 460/3/60 12 63 INDOOR FAN - Type Centrifugal Dia. /Width (In.) 11.8/9.5 No. Used /No. Motors 1/1 Drive / Speeds (no.) Direct f/ 3 Motor HP - Speed (RPM) 1 -1 75 Volts /Ph. /Hz. 230/1/60 Amps (Nameplate) F.L. 6.4 Centrifugal 11.8/9.5 1/1 Direct / 3 1 - 1075 200-230/1/60 6.4 Centrifugal 11.8/9.5 1/1 Direct / 3 1 - 1075 460/1/60 2.5 OUTDOOR FAN - Type Propeller No. Used - Dia. (in.) 2 -16 Drive / Speeds (no.) Direct / 1 Motor HP - Speed (RPM) 1/5 - 1625 Volts /Ph. /Hz. 230/1/60 Amps (Nameplate) F.L. Each 1.3 Propeller 2 -16 Direct 1 1/5 - 1625 200-230/1/60 1.3 Propeller 2 -16 Direct / 1 1/6 - 1625 460/1/60 0.6 COMBUSTION FAN - Type Centrifugal .No. Used - Dia. /Width (in.) 1 - 12.62/1 Drive / Speeds (no.) Direct / 1 Motor HP - Speed (RPM) 1/5 -1625 Volts /Ph. /Hz. 230/1/60 Amps (Nameplate) F.L. 1.5 Centrifugal 1 - 12.62/1 Direct 1 1/5 - 1625 200-230/1/60 1.5 Centrifugal 1 - 12.62/1 Direct / 1 1/5 -1625 460/1/60 0.79 OUTDOOR COIL - Type Plate Fin Rows F.P.I. 3 / 13 Face Area --- (sq. ft.) 8.33 Tube - Size (in.) 1/2 Plate Fin 3 / 13 8.33 1/2 Plate Fin 3 / 13 8.33 1/2 INDOOR COIL - Type Plate Fin Rows /F.P.I. 3/13 Face Area - (sq. ft.) 5.33 Tube - Size (In.) 1/2 Refrigerant Control Capillary Tube Plate Fin 3/13 5.33 1/2 Capillary Tube Plate Fin 3/13 5.33 1/2 Capillary Tube FILTER (Not Furnished) Type Recommended 1" Throwaway No. /Size (in.) Recommended 7.5 Sq. Ft. Min. 1" Throwaway 7.5 Sq. Ft. Min. 1" Throwaway 7.5 Sq. Ft. Min. REFRIGERANT FACTORY Charge (lbs. of R -22) ® 8.5 lbs. 8.5 lbs. 8.5 lbs. GAS PIPE SIZE (in.) 1/2 1/2 1/2 • FLUE CONNECTION NOT REQUIRED CONDENSATE DRAIN size (in.) 3/4 NPT I 3/4 NPT 3/4 NPT DUCT CONNECTIONS W H / W H Supply an.)/Return (in.) 18-1/2 x 20-1/2/ 24-5/8x 30-1/4 DIMENSIONS Crated (in.) Uncrated - Detail H 37 I W I D 57 -3/4 48 ` H I W I D I 37 f 57-3 /4 48 DRAWINGS) I H 37 I 57 -3/4 48 SEE OUTLINE . WEIGHT Shipping (lbs.) / Net (lbs.) Corner Weights 619 / 607 I 619 607 SEE OUTLINE DRAWING(S) I : 619 / 607 '(,� - • GENERAL ELECTRIC PRODUCT DATA CENTRAL AIR CONDITIONING DEPARTMENT. TROUP HIGHWAY. TYLER, TEXAS 75711 OO R in accordance with A.RJ. Standard 210. ®O Rated in accordance with ARl Standard 270. 6 SINGLE PACKAGE BYCO6OB PRODUCT SPECIFICATIONS O All Models are American Gas Association certified. limit settings and rating data weir estab �sY d and approved under Laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% br each 1,000 feet above sea level. C) Factory shipped with natural gas high input orifices installed but natural gas low input and LPG high input orifices and conversion instructions are shipped with unit. 0 Calculated in accordance with currently prevailing National Electric Code. © This value is approximate. For more precise value, see nameplate and service instructions. Based on U.S. Government standard test. ..ate►. �/ DATA SUBJECT TO CHANGE WITHOUT NOTICE . r• Job Information MACDONALD MILLER FACILITY -- NC POWER GP -1 Tag Quantity Y4C -1 1 FILE COPY Model number YSC060 Unit Information Tonnage Min. unit operating weight Design Airflow 5 Ton 613.0 lb 2000 cfm Unit function Max. unit operating weight 825.0 lb DX cooling, gas heat Cooling Information Gross Total Capacity Gross Latent Capacity Net Sensible Capacity Cooling Entering DB Cooling Leaving Unit DB Ambient Temp 62.27 MBh 14.16 MBh 44.94 MBh 80.00 F 59.20 F 95.00 F Gross Sensible Capacity Net Total Capacity Net Sensible Heat Ratio Cooling Entering WB Cooling Leaving Unit WB 48.11 MBh 59.10 MBh 0.76 Number 67.00 F 57.50 F Heating Information Heating capacity Output Heating Capacity Heating LAT Medium gas heat 3ph 64.00 MBh 99.90 F Input Heating Capacity Heating EAT Heating Delta T 80.00 MBh 70.00 F 29.90 F Motor /Electrical Information 7/29/2009 3 -10 Ton R410A PKGD Unitary Gas /Electric Rooftop Voltage Indoor Motor Power Indoor RPM Compressor Power MCA Compressor 1 RLA Condenser fan FLA 460/60/3 0.72 kW 1076 rpm 4.34 kW 0.00 A 9.60 A 1.30 A Design ESP Indoor mtr operating power Outdoor Motor Power System Power SEER/EER @ ARI MOP Evaporator fan FLA 0.50 in H2O 0.96 bhp 0.40 kW 4.79 kW 13.00 btuh/watt 0.00 A 2.50 A R E V I E W E C O D E COMPLIANCE APPROVED AUG 1 2009 City of Tukwila BUILDING DIVISION Electrical values provided are estimated only and are subject to change without notice and may differ from nameplate values. Field installed low or high static drive kits may be needed. Please check the fan performance tables in the product catalog for application ranges. RECEIVED CITY OF TUK MLA AUG 0 3 2009 PERMIT CENTER o cr 5 -10 Ton R410A PKGD Unitary Gas/Electric Rooftop • Items: Y4C -1 This item is not 'In Job') '/29/2009 8:17:56 AM 3 5/8 "-H 4" 24" 4 3/16" EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 3/4 " -14 NPT DAI. HOLE 14" RETURN 23 1/2" THROUGHTHE BASE CONDENSATE 91/4" 15 1/2' 16" 4 1/4" 23 9/16" 42 1/4" SUPPLY t jjj 1/2" GAS CONNECTION 4 9/16" MACDONALD MILLER FACILITY -- NC POWER GP -1 4 7/8 "--» o- 5 1/16"-c- 27 9/16" DOWNFLOW- PENETRATION 17 1/4 CONDENSATE 89 7/8" HORIZONTAL - PENETRATION 2 13/16" 3 11/16" 23 1/4" 4 3/4" 3/16" TOP PANEL CONTROL AND COMPRESSOR ACCESS PANEL 1/2" NPT GAS CONNECTION ISOMETRIC - PACKAGED THROUGH THE BASE ELECTRICAL (REQUIRES FACTORY INSTALLATION) 36 CONDENSER FAN CONDENSER COIL UNIT CONTROL WIRE 7/8" DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/8" DIA. HOLE UNIT POWER WIRE AIR FLOW RIGHT - PACKAGED TRANI" HORIZONTAL AIR FLOW TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. CERTIFIED PRINTS ARE AVAILABLE UPON REQUEST. Page: 1 w.:: V4 *.ti i • ti L . • Y•L' I ''• '• ' }: } {.} 7 143/4" :: RETURN SUPPLY 1 /4" 5 -10 Ton R410A PKGD Unitary Gas/Electric Rooftop • Items: Y4C -1 This item is not 'In Job') '/29/2009 8:17:56 AM 3 5/8 "-H 4" 24" 4 3/16" EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 3/4 " -14 NPT DAI. HOLE 14" RETURN 23 1/2" THROUGHTHE BASE CONDENSATE 91/4" 15 1/2' 16" 4 1/4" 23 9/16" 42 1/4" SUPPLY t jjj 1/2" GAS CONNECTION 4 9/16" MACDONALD MILLER FACILITY -- NC POWER GP -1 4 7/8 "--» o- 5 1/16"-c- 27 9/16" DOWNFLOW- PENETRATION 17 1/4 CONDENSATE 89 7/8" HORIZONTAL - PENETRATION 2 13/16" 3 11/16" 23 1/4" 4 3/4" 3/16" TOP PANEL CONTROL AND COMPRESSOR ACCESS PANEL 1/2" NPT GAS CONNECTION ISOMETRIC - PACKAGED THROUGH THE BASE ELECTRICAL (REQUIRES FACTORY INSTALLATION) 36 CONDENSER FAN CONDENSER COIL UNIT CONTROL WIRE 7/8" DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/8" DIA. HOLE UNIT POWER WIRE AIR FLOW RIGHT - PACKAGED TRANI" HORIZONTAL AIR FLOW TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. CERTIFIED PRINTS ARE AVAILABLE UPON REQUEST. Page: 1 I ''• '• ' }: } {.} • ... k $.. ;.: M: :: 1 /4" 11111 . „ 9 5/8" . 5 5/8" I liitl- 11�1 i 4 1/4" 59/16" 7 5/8' ii 44 1/4" 5 -10 Ton R410A PKGD Unitary Gas/Electric Rooftop • Items: Y4C -1 This item is not 'In Job') '/29/2009 8:17:56 AM 3 5/8 "-H 4" 24" 4 3/16" EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 3/4 " -14 NPT DAI. HOLE 14" RETURN 23 1/2" THROUGHTHE BASE CONDENSATE 91/4" 15 1/2' 16" 4 1/4" 23 9/16" 42 1/4" SUPPLY t jjj 1/2" GAS CONNECTION 4 9/16" MACDONALD MILLER FACILITY -- NC POWER GP -1 4 7/8 "--» o- 5 1/16"-c- 27 9/16" DOWNFLOW- PENETRATION 17 1/4 CONDENSATE 89 7/8" HORIZONTAL - PENETRATION 2 13/16" 3 11/16" 23 1/4" 4 3/4" 3/16" TOP PANEL CONTROL AND COMPRESSOR ACCESS PANEL 1/2" NPT GAS CONNECTION ISOMETRIC - PACKAGED THROUGH THE BASE ELECTRICAL (REQUIRES FACTORY INSTALLATION) 36 CONDENSER FAN CONDENSER COIL UNIT CONTROL WIRE 7/8" DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/8" DIA. HOLE UNIT POWER WIRE AIR FLOW RIGHT - PACKAGED TRANI" HORIZONTAL AIR FLOW TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. CERTIFIED PRINTS ARE AVAILABLE UPON REQUEST. Page: 1 3 -10 Ton R410A PKGD Unitary Gas /Electric Rooftop (Y4C) "Items: Y4C -1 •(This item is not 'In Job') 7/29/2009 8:17:58 AM / 3/4 " -14 NPT DEAIN CONNECTION MACDONALD MILLER FACILITY -- NC POWER GP -1 RETURN 23 9/16" \4 1/4" ISOMETRIC - PACKAGED COOLING E ® TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. CERTIFIED PRINTS ARE AVAILABLE UPON REQUEST. Page: 2 'GENERAL (2)(4)(6) Model: YSC060E Oversized Motor HEATING PERFORMANCE HEATING - GENERAL DATA Unit Operating Voltage: 414 -506 MCA: N/A : odel Heating Model: l Media m Medium Unit Primary Voltage: 460 MFS: N/A Heating (Btu): 80,000 Unit Secondary Voltage Unit Hertz: rtz: 6 0 6 MCB: N/A Heating Output (Btu): 64,000 Unit Phase: 3 No. Burners: 2 No. Stages 1 SEER 13.0 Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: 15.5 MCA: N/A Natural Gas (Min/Mix): 4.5/10.5 MFS: 25.0 MFS: N/A LP (Min/Max) 10.0/13.0 MCB: 25.0 MCB: N/A Gas Pipe Connection Size: 1" / 2" INDOOR MOTOR Sandard Motor Oversized Motor Field Installed Oversized Motor Number: 1 Number. N/A Number: N/A Horsepower. 1.0 Horsepower. N A Horsepower. N/A Motor Speed (RPM): -- Motor Speed (RPM): N/A Motor Speed (RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 2.5 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: 16.1 Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: 1 Number. 1 Horsepower. 4.3 Horsepower: 0.40 Phase: 3 Motor Speed (RRM): 1075 Rated Load Amps: 9.6 Phase: 1 Locked Rotor Amps: 62.0 Full Load Amps: 1.0 Locked Rotor Amps: 2.8 POWER EXHAUST ACCESSORY 131 FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type: Throwaway Horsepower. N/A Fumished: Yes Factory Charge Motor Speed (RPM): N/A Number 2 Ciruit #1 9.4 Full Load Amps: N/A Recommended 20 "x30"x1" Ciruit #2 N/A Locked Rotor Amps: N/A 3 -10 Ton R410A PKGD Unitary Gas /Electric Rooftop (Y4C) *Items: Y4C -1 `(This item is not 'In Job') 7/29/2009 8:17:58 AM MACDONALD MILLER FACILITY -- NC POWER GP -1 'ELECTRICAL / GENERAL DATA NOTES: 1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not include Power Exhaust Accessory. 6. EER is rated at ARI conditions and in accordance with DOE test procedures. TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. CERTIFIED PRINTS ARE AVAILABLE UPON REQUEST. Page: 3 ACCESSORY WEIGHTS ECONOMIZER 26.0 lb MOTORIZED OUTSIDE AIR DAMPER N/A MANUAL OUTSIDE AIR DAMPER N/A BAROMETRIC RELIEF N/A OVERSIZED MOTOR N/A BELT DRIVE MOTOR N/A POWER EXHAUST N/A THROUGHT THE BASE ELECTRICAL (FIOPS) N/A UNIT MOUNTED CIRCUIT BREAKER (FIOPS) N/A UNIT MOUNTED DISCONNECT (FIOPS) N/A POWERED CONVENIENCE OUTLET (FIOPS) N/A HINGED DOORS (FIOPS) HAIL GUARD N/A SMOKE DETECTOR, SUPPLY / RETURN N/A NOVAR CONTROL N/A STAINLESS STEEL HEAT EXCHANGER N/A ROOF CURB N/A BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET O 190.0 lb O 110.0 lb (E) LENGHT (F) WIDTH 688.0 lb 613.0 lb © 158.0 lb ( 155.0 lb 31" 19" 3 -10 Ton R410A PKGD Unitary Gas/Electric Rooftop (Y4C) - Items: Y4C -1 -(This item is not 'In Job') 7/29/2009 8:17:58 AM eAt vqg CORNER WEIGHT MACDONALD MILLER FACILITY -- NC POWER GP -1 NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3. BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT. TO OBTAIN TOTAL WEIGHT, ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE >5 LBS. RIGGING AND CENTER OF GRAVITY INSTALLED ACCESSORIES NET WEIGHT DATA TES TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. CERTIFIED PRINTS ARE AVAILABLE UPON REQUEST. Page: 4 3 -10 Ton R410A PKGD Unitary Gas /Electric Rooftop (Y4C) items: Y4C -1 '(This item is not 'In Job') 7/29/2009 8:17:59 AM ROOF OPENING UNIT OUTLINE CLEARANCE 36" CLEARANCE 36" MACDONALD MILLER FACILITY -- NC POWER GP -1 PACKAGED COOLING CLEARANCE 40" 68 3/16" 37" DOWNFLOW -ROOF OPENING CLEARANCE 48" CLEARANCE 37" CLEARANCE FROM TOP OF UNIT n• 44 1/2" MANE° TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. CERTIFIED PRINTS ARE AVAILABLE UPON REQUEST. Page: 5 3 -10 Ton R410A PKGD Unitary Gas/Electric Rooftop (Y4C) 'Items: Y4C -1 - (This item is not 'In Job') 7/29/2009 8:17:59 AM BAROMETRIC RELIEF HOOD 4 6 15/16" 8 MACDONALD MILLER FACILITY -- NC POWER GP -1 BAROMETRIC RELIEF HOOD ACCESSORY - BAROMETRIC RELIEF DAMPER HOOD ECONOMIZER HOOD TE° TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. CERTIFIED PRINTS ARE AVAILABLE UPON REQUEST. Page: 6 3 -10 Ton R410A PKGD Unitary Gas /Electric Rooftop (Y4C) items: Y4C -1 '(This item is not 'In Job') 7/29/2009 8:18:00 AM MACDONALD MILLER FACILITY -- NC POWER GP -1 ECONOMIZER HOOD ACCESSORY - ECONOMIZER HOOD 12 112' ECONOMIZER HOOD TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. CERTIFIED PRINTS ARE AVAILABLE UPON REQUEST. Page: 7 3 -10 Ton R410A PKGD Unitary Gas/Electric Rooftop (Y4C) items: Y4C -1 - (This item is not 'In Job') 7/29/2009 8:18:00 AM MACDONALD MILLER FACILITY -- NC POWER GP -1 General The units shall be convertible airflow . The operating range shall be betw een 115 ° F and 0 °F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115 ° F and 40 ° F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R -410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to UL 1995 /CAN/CSA No. 236 -M90 for Central Cooling Air Conditioners. Canadian units shall be CSA Certified. Casing Unit casing shall be constructed of zinc coated, heavy gauge, and galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a w eather- resistant baked enamel finish. Unit's surface shall be tested 1000 hours in a salt spray test in compliance w ith ASTM 6117. Cabinet construction shall allow for all maintenance on one side of the unit. All exposed vertical panels and top covers in the indoor air section shall be insulated w ith a cleanable foil- faced, fire - retardant permanent, odorless glass fiber material. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8" high dow nflow supply /return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, w ith forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, w here seams exist, it shall be double - hemmed and gasket - sealed. The ribbed top adds extra strength and enhances w ater removal from unit top. Refrigerant Circuits Service pressure ports, and refrigerant line filter driers are factory - installed as standard. An area shall be provided for replacement suction line driers. Compressors All units shall have direct - drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas - cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Crankcase heaters shall be included. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 200 psig and pressure tested to 450 psig. The condenser coil shall have a patent pending 1 +1 +1 hybrid coil designed with slight gaps for ease of cleaning. A removable, reversible, double - sloped condensate drain pan w ith provision for through the base condensate drain is standard. Outdoor Fans The outdoor fan shall be direct - drive, statically and dynamically balanced, draw - through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built -in thermal overload protection. Indoor Fan All 3 -5 ton 1 -phase units offer shall be direct drive type. All 3 phase ID motors shall be belt drive type with FC fans w ith adjustable sheaves. All motors shall be thermally protected. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPA CT). TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. CERTIFIED PRINTS ARE AVAILABLE UPON REQUEST. Page: 1 3 -10 Ton R410A PKGD Unitary Gas/Electric Rooftop (Y4C) Items: Y4C -1 '(This item is not 'In Job') 7/29/2009 8:18:01 AM MACDONALD MILLER FACILITY -- NC POWER GP -1 INANE Controls Unit shall be completely factory -w ired w ith necessary controls and contactor pressure lugs or terminal block for power w iring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for volt control functions. The resident control algorithms shall make all heating, cooling, and /or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized Microprocessor shall provide anti -short cycle timing and time delay betw een compressors to provide a higher level of machine protection. Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0 -100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blow er shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field - installed kit) and also comply w ith the California requirement for low NOx emissions (Gas /Bectric Only). TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. CERTIFIED PRINTS ARE AVAILABLE UPON REQUEST. Page: 2 DEPARTMENTS: 1? Division Public Works Complete Comments: Documents/routing slip.doc 2 -28 -02 og DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M09 -096 DATE: 08 -03 -09 PROJECT NAME: NC MACI N ERY - POWER SYSTEMS SITE ADDRESS: 17900 WEST VALLEY HY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued N //� 8-467 ire Preventi Structural Incomplete n Planning Division ❑ Permit Coordinator DUE DATE: 08-04-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required n DATE: Approved ❑ Approved with Conditions C Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: n DUE DATE: 09-01-09 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI*988RC DIVCO INCORPORATION CONSTRUCTION CONTRACTOR GENERAL UNUSED 12/3/2002 11/7/2010 ACTIVE MACDOMR026RU MACDONALD MILLER RSDNTL INC CONSTRUCTION CONTRACTOR UNUSED GENERAL 12/31/1998 12/31 /2001 ARCHIVED MACDOMR076OPMILLER MACDONALD RESIDENTIAL CONSTRUCTION CONTRACTOR GENERAL UNUSED 9/17/1993 12/30/1998 ARCHIVED DIVCOEC188LC DIVCO ENERGY CONTROL COMPANY CONSTRUCTION CONTRACTOR GENERAL UNUSED 6/3/1982 5/26/1997 ARCHIVED MACDOM *248J9 MACDONALD MILLER CO CONSTRUCTION CONTRACTOR GENERAL UNUSED 4/29/1976 2/1/2002 ARCHIVED ENCOMMS984CA ENCOMPASS MECHANICAL SERVICES CONSTRUCTION CONTRACTOR GENERAL UNUSED 2/1/2002 2/1/2004 EXPIRED LINFOAR980QG LINFORD AIR & REFRIGERTN INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 11/7/2002 11/7/2004 INACTIVE DIVCOI*031L4 DIVCO INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 6/24/1997 8/1/2003 REREGISTERED Untitled Page • • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MACDONALD /MILLER FAC SOL INC 2067684180 PO BOX 47983 SEATTLE WA 98106 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602254260 ACTIVE MACDOFS980RU CONSTRUCTION CONTRACTOR 12/31/2002 12/31/2010 GENERAL UNUSED Other Associated Licenses Page 1 of 2 Business Owner Information Name Role Effective Date I Expiration Date https://fortress.wa.gov/lni/bbip/Detail.aspx 08/11/2009 NC POWER SYSTEMS SITE AREA OF WORK WEST VALLEY HIGHWAY S 180TH STREET T rilA Mks ae UNIT NO. MFG & MODEL NO. RTU -1 TRANE YSC064 RTU -3 CARRIER 48HJE004 RTU - 5 CARRIER 48HJE006 NOTES: 1 PROVIDE, ECONOMIZER &i7`DAY;PRO:GRf11VIMABLE;T-STA 2. MM= TQ:PROVID "E::CURB�: ;OR;; CURB; ADAPTER !.;=:? 'iSCONNFC S Et EC 7 I :CONTROLS WIRING BY USE EXISTING GAS LINES MEASURE & .MATCH EXISTING OSA CONDITION NOM GAS HEAT MBH TONS 1 INPUT OUTPUT CFM ESP 5.0 64 80.00 1950 0.5 3.0 72 59.00 1200 0.5 5.0 72 59.00 1950 0.5 FAN OSA CFM to :NOTE 5 1/2 ;NOTE 5 3/4 :NOTE 5 EERI ` ELECTRICAL SEER i IPLV ° VOLT /PH MCA 1 LBS 13 i 460/3 15,5 613 13 208/1 25.6 530 208/1 44.1 610 13 WT NOTES NEW, 1-5 1, 2, 3, 4, 5 EXIST 1, 2, 3, 4, 5 TITLE PROJECT ENGINEER ACCOUNT MANAGER REFRIGERATION FOREMAN FITTING FOREMAN AIR BALANCE FIELD FOREMAN FIELD FOREMAN SHEET METAL FOREMAN SHEET METAL FOREMAN ELECTRICAL FOREMAN NAME KRIS JOHANSON KEVIN WILDER DEAN GRASSER JASON ZEMBRYCKI STEVE BAKER LARRY HARBISON CHRIS HOLLINGSWORTH BILL BRITTAIN SAM VERT COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER PHONE NUMBER 206 - 407 -2628 253- 680 -3168 206- 768 -4270 206- 768 -3860 206- 768 -3824 206 - 768 -4294 206- 407 -2620 206 -407 -2652 206 -407 -2638 FAX NUMBER 206 -407 -2629 206 - 768 -4271 206 - 768 -3861 206 -768 -3825 206 - 768 -4295 206 - 407 -2621 206 - 407 -2653 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. IFILECs Y Permit No. Vi 0 O1 (P Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize isle violation of any adopted code or ordinance. Receipt of approved eld Copy and conditions Is acknowledged: By Date: '/I /0c. City Of TUkwiia BUILDING DIVISION VICINITY MAP NO SCALE REVIEWED FOR CODE COMPLIANCE A O AUG 10 2009 (J�� (Mt City of Tukwila BUILDING DIVISION 1. THE HVAC SYSTEM FOR THIS PROJECT IS BASED ON THE FOLLOWING CRITERIA: ROOF "U" VALUE (BTUH /S.F. °F) = N/A WALL "U" VALUE (BTUH /S.F. °F) = N/A FLOOR "U" VALUE (BTUH /S.F. ° F) = N/A GLASS "U" VALUE (BTUH /S.F. °F) = N/A GLASS SHADE COEFF. = N/A LIGHTING (WATTS /S.F.) = N/A MISC. EQUIP. (WATTS /S.F.) = N/A PEOPLE DENSITY (S.F. /PERSON) = N/A COOLING INDOOR DESIGN TEMP "F = N/A COOLING OUTDOOR DESIGN TEMP ( °F) = N/A HEATING INDOOR DESIGN TEMP ( °F) = N/A HEATING OUTDOOR DESIGN TEMP ( °F) = N/A 2. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 3. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2006 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 4. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2006 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 5. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 6. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2006 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED Et 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R-4.3 MIN.). 7. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2006 IBC. 9. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE /SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2006 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2006 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 10. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 11. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2006 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 12, HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18 ", 13. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND. INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 14, MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 15. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 16. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 17. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION '1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 18. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 19. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ( "MONOCOAT ") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2006 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. Y - ALL DOORS MUST BE PROVIEDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE, 20. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS :10 CFM /S.F. GRAVITY DAMPERS: 20CFM /S.F. (40 CFM /S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 21. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. 22. RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.C. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL. DIFFERENTIAL PRESSURE IS BASED UPON THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE. 23. PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS: - SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE. - SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1 -2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE. - FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC PRESSURE, CONTACT MECHANICAL ENGINEER. APN # 3623049011 LEGAL DESCRIPTION: 362304 11N 330 FT OF S 450 FT OF POR OFGL 2 & OF NE 1/4 OF NW 1/4 LYELY OF W VALLEY RD & W OF P S E TRANS LN RNW & N OF & TH PLW N LN OFS 180TH ST TGW E 60 FT OFW 260 FT OF N 120 FT OF S '150 FTOF SAID NE 1/4 OF NW 1/4 LESS ST LESS STATE HWY TGW PORTION OFNW 1/4 - BEGIN 1373.75 FT W& 93 FT N OF NE CORNER OFHENRY ADAMS D C TH N 57 FT TH W 94 FT TO E LINE OF STATEROAD NO 5-M TH SELY ALONGSAID E LINE 61 FT E 72 FTTO POB LESS PORTION FOR SR 181 REMOVE AND REPLACE EXISTING 5 TON ROOFTOP PACKAGE UNIT. INSTALL NEW ADAPTER CURB AND DISCONNECTS. CONTROL WIRING & GAS PIPING TO BE REUSED. e w Z Y ;, ..•<. NAME TITLE ................. TM0.01 SCHEDULES - HVAC TM2.03 ROOF PLAN- HVAC TM6.O1 ELEVATION VIEW -HVAC NAME TITLE RECEIVED rim OF TUKWILA AUG 0, 3 2009 PERMIT CENTER 5 co co CO I-- 'GINEER: JOHANSON 4ECKED BY B GEZON CAD: D IKERD DRAWING NUMBER: C -1378 -7396 SHEET NUMBER: CO CY) rna ai �'E +� U a> coo 0 ca >C') 4 o8 N 0 r= o I w O Q M D N- O a co 0) U 0 2 2 . LAST REVISED: 07 -30 -09 DATE PLOTTED: 07 -30 -09 ISSUE DATE: 07 -30 -09 615 -00 TM0.01 J:\739\6615 NC Power GP#1 Replace — July 31, 2009 2:01:30 120' PAR \ 0 PROP 'KING C-ANGE) ERTY LI \IE PROPERTY LIN PROPERTY LINE MO'? 0% REVIEWED MR CODE COMPLIANCE A t'PROVED AUG 1 0 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 03711119 PERMIT CENTER 3/32" = V-0" 0 U 0 co cr) LL. 0 z Ci 7.1 I I I I I S I LU I I- 0 < r0 0 N 0 (..nw 0 I I I I I 1`11 1 I E 0 a ) E LU cc TM0.01S ENGINEER: LAST REVISED: K JOHANSON 07-30-09 CHECKED BY DATE PLOTIED: B GEZON 07-30-09 CAD: ISSUE DATE: D IKERD 07-30-09 DRAWING NUMBER: C 1 3 7 8 — 7 3 9 6 6 1 5 0 0 SHEET NUMBER: f — 3 I EXISTING SKYLIGHT (TYP) HP-5 N A DEMO EXISTING 5 TON ROOFTOP PACKAGE UNIT AND REPLACE WITH NEW 5 TON ROOFTOP PACKAGE UNIT REUSE AND RECONNECT EXIST GAS LINE AND ELECTRICAL CONNECTIONS 36' >I REVIEWED F OR CODE COMPLIANCE AIPPRONED AUG 1 0 2009 City of Tukwila BUILDING DIVISION RECENED CITY OF TUKWILA AUG Q3 2009 PERMIT CENTER 1/8" = ENGINEER: K JOHANSON CHECKED BY: B GEZON CAD: D IKERD DRAWING NUMBER: SHEET NUMBER: C-1378-73966 0 0 0 I1 E E e 4 LAST REVISED: 07-30-09 DATE PLOTTED: 07-30-09 ISSUE DATE: 07-30-09 15-00 TM2.03 Friday, July 31, 2009 2:01:01 PM 0 RTU-1 REPLACEMENT NC POWER SYSTEMS 17900 WEST VALLEY HWY TUKWILA, WA 98188 4 A ? -- LI r-- % r„,,,,,,, . f ,;, f / = , , , ,T : Fr t. k., ,, „y 4 $ •L il.,:,,.. vi . 51 X ,.. ll .," . ...? : ,, ,i,,,, : P-1xt:gaRre.i's, ' 4 'T.? VI Or • '' 11 ...,,p.: .7•04- --, x•.,. - • za• .-,', id ISSUED FOR CONSTRUCTION 1 cJ OVVIA NV % • NW • ANV't NVV1 ANVt ' AMA • IVVV1 • gONAI: _ _ A CD SET 07-30-09 _ _ WIRES 7/6/0 REVISIONS: DATE REVISIONS: DATE J:\739\6615 NC Power GP#1 Replace — KW\00\Eng\DwASHTS\7396615TM6_01.dwg MacDonald-Miller kiAd: ft— A f14-P 7717 Detroit Avenue SW, Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 wvvw.macmiller.com WA Lie No: MACDOFS980RU z Z\ CD SET REVISIONS: WA - N'Wt NNAA • 07-30-09 DATE REVISIONS: DATE EXPIRES 7/6/0 1 J:\739\6615 NC Power GP#1 Replace — KW\00\Eng\Dwg\SHTS\7398615TM6_01,dwg MacDonald-Miller a 0 A, • I.! • . 7717 Detroit Avenue SW, Seattle, WA 98106 Phone: 206-763-9400 Fax: 206-767-6773 www.macmiller.com WA Lie No: MACDOFS980RU