Loading...
HomeMy WebLinkAboutPermit M09-099 - AVIATION PARTNERS BOEINGAVIATION PARTNERS BOEING 2811 S 102 ST M09 -099 Parcel No.: 0423049190 Address: Suite No: 2811 S 102 ST TUKW City 41 1f Tukwila Tenant: Name: AVIATION PARTNERS BOEING Address: 2811 S 102 ST , TUKWILA WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contact Person: Name: DAVID BOOMER Address: 2100 196 ST SW, STE 122 , LYNNWOOD WA Contractor: Name: D/B SOLUTIONS LLC Address: 10627 90 ST NE , LAKE STEVENS WA Contractor License No: DBSOLSL934BK MECHANICAL PERMIT Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTERN'L BLVD , FOURTH FLOOR DESCRIPTION OF WORK: RELOCATE 20 DIFFUSERS AND INSTALL (9) THERMOSTATS (T -STATS TO BE PERMITTED UNDER SEPARATE ELECTRICAL PERMIT) Value of Mechanical: $22,668.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 EOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** M09 -099 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 744 -6300 Phone: 425 737 -4042 Expiration Date: 01/29/2011 M09 -099 08/07/2009 02/03/2010 Fees Collected: $448.51 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 30 Thermostat 9 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 08 -07 -2009 Permit Center Authorized Signature: Signature: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: M09 -099 Issue Date: 08/07/2009 Permit Expires On: 02/03/2010 Date: Date: o$l aa��, I hereby certify that I have read and e ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of �rror� autYized to sign and obtain this mechanical permit. (e2U- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -099 Printed: 08 -07 -2009 Parcel No.: 0423049190 Address: Suite No: Tenant: 2811 S 102 ST TUKW • d City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us AVIATION PARTNERS BOEING 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M09 -099 ISSUED 08/07/2009 08/07/2009 2: No changes shall be made to the approved plans unless approved by the design professional m responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * * continued on next page ** M09 -099 Printed: 08 -07 -2009 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: .._ Date: Print Name: Ok Z City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us doc: Cond -10/06 M09 -099 ordinances governing or local laws regulating Printed: 08 -07 -2009 King Co Assessor's Tax No.: Site Address: z 11 Snu Tt+ 1 C Z pis. 5 i" Suite Number: Floor: Tenant Name: A v 1 A Tt n 0 7 (-ek te:-i -wi tie s L e n: 11 J C., New Tenant: Ej .... Yes D ..No Property Owners Name: e/ �; C o l .o r--... r i c> A-) Mailing Address: 12_ Z p \ Name: S ID AV It> Mailing Address: Z1 1:90 t 4 t Cyr ti ; S V° Ot (Z Z Y Aiu wo 0 City 11 E -Mail Address: ,:14A v St› spy , o1s+1.e. - n�T Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKW1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cttukwila.wa.us Contractor Registration Number: MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** aKt,JtL L c> 21 v o 1c b r�► ' r St.t) 4 .1.1e4vid a .tJ!? FL 11(.9n S /1-s , . o - -4 Q \Applications\Forms- Applications On Line \3-2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh 1 Al Sr 40 City Day Telephone: 0 State KJ 01 State Fax Number: 4 2 5 • 'T 44 - L3 41 Zip a lga3t, Zip 4r l Zz Lyw,A woos 0 )4 1 City State Zip Day Telephone: A z S. 7 • 3 n Fax Number: 4 Z 5 -744.&4! Expiration Date: City Day Telephone: Fax Number: State State Zip City Day Telephone: Fax Number: Zip Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU 0 Air Handling Unit >10,000 CFM O Fire Damper 0 0 -3 HP /100,000 BTU 0 Furnace >100K BTU D Evaporator Cooler O Diffuser it E % ,nc I►Te_ "'S o 3 -15 HP /500,000 BTU p Floor Furnace 0 Ventilation Fan Connected to Single Duct V Thermostat fe mac_ oe_ r , E 15 -30 HP /1,000,000 BTU J Suspended /Wall/Floor Mounted Heater O Ventilation System O Wood /Gas Stove 0 30 -50 HP /1,750,000 BTU O Appliance Vent 0 Hood and Duct t2 Water Heater 0 50+ HP /1,750,000 BTU t.) Repair or Addition to Heat/Refrig/Cooling System 1 Incinerator - Domestic Emergency Generator O Air Handling Unit <10,000 CFM 0 Incinerator — Comm/Ind ' Other Mechanical Equipment E1 Valuation of Project (contractor's bid price): $ ZZ , ' Scope of Work (please provide detailed information): 1 ` D E" i t - F' 4 "� Use: Residential: New ....ED Replacement .... Commercial: New .... 0 Replacement .... Fuel Type: Electric 0 Gas .... J Other: Indicate type of mechanical work being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO Date Application Accepted: AGENT: City Q:\Applications\Forms- Applications On Line\3 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh Date: 4 E 5 1 Signature: Print ame: v t `L c - r c Day Telephone: ii Z E — I 4' , 10 s 4' Mailing Address: Z 1 ) c 1 �` �+ -� —� 1 Ly .-s') . LA/ ✓}-- '°G 0303 State Zip Date Application Expires: Staff Initials: Page 2 of 2 Parcel No.: 0423049190 Permit Number: M09 -099 Address: 2811 S 102 ST TUKW Status: APPROVED Suite No: Applied Date: 08/07/2009 Applicant: AVIATION PARTNERS BOEING Issue Date: Receipt No.: R09 -01243 Initials: User ID: Payee: JEM 1165 ACCOUNT ITEM LIST: Description D/B SOLUTIONS NORTHWEST LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3211 358.81 Authorization No. MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000.322.102.00.0 358.81 Total: $358.81 Payment Amount: $358.81 Payment Date: 08/07/2009 01:47 PM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 08 -07 -2009 Project: Type of Inspection: Addr s: 2 k1 S 1 o2 .r - Date Called: Special Instructions: 039 3_ 6 1 Date Wanted: ° t - 23 a.m. am. - Requester: Phone No: ' , --- )37 - G - (Li Ye._ INSPECTION RECORD Retain a copy with permit - INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ENTS: 0 —er-ev..sz ea .:\ 0 Inspecto Dat x .00 INSPECTION FEE REQ IRED. P ' o inspection, fee ust be id atfi Southcenter Blvd., Suite 100. Ca to schedule rei spection. or Receipt o.: / Date: A pproved per applicable codes. Corrections required prior to approval. 1� Projf.st: 4 Type of Inspection: Address: - e9// s /2 s7 Date Called: Special Instructions: Date Wa ted: 5— 8 v 7 p.m. Requester: Pho a No: ' INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 `igi Approved per applicable codes. 0 Corrections required prior to approval. 7 COMMENTS: /),09, Ivy/1/d L. In /Am 1 60. pat REINSPECTION FE REQUIRO. Prior to inspection, fee must be at 6300 Southcenter vd., Suit 100. Call to schedule reinspection. Date -3-65 R =ce'.t No.: 'Date: Project: . 0!/9 166,0 >497 of Inspection: Af>ie) i N✓ Address: 02 c"/ S /0 .? .5 Date Called: Special Instructions: Date Wanted: 9 '- Q 5 p.m: Requester: CITY OF TUKWILA DIVISION 6300 Southcenter Blvd., #1.00, Tukwila, WA 98188 • Ell Approved per applicable codes. Corrections required prior to approval. r COMMENTS: .14/ / /?OQsfs ft1 .2/act/ 46 404/ /t/I 4 S "467 1' / 7 rh/#7 e C .mac/. c a5/)btJ 7v INSPECTION NO. INSPECTION RECORD. Retain a copy with permit 'Date: PERMIT NO. (206)431 -3670 Da 1 2 _`r, .00 REINSPECTION'PEE IJ OUIRED. Prior to inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 3 Mv5—o,'9 Certified Test, Adjust and Balance Report Project: Address: Mechanical Contractor: Address: AIRTCS T Co. Inc. Aviation Partners Boeing Tukwila, WA DB Solutions LLC 10627 - 90th Street NE Lake Stevens, WA 98258 TAB Supervisor: Mike Touchette NEBB Certification: 3000 Date: September 23, 2009 PD. Box 86 • Issaquah, Washington 98027 • (425) 313 -0172 • Fax (425) 313 -5735 1 of 8 PROJECT: ADDRESS: Tukwila, WA THE DATA PRESENTED IN THIS REPORT IS A RECORD OF SYSTEM MEASUREMENTS AND FINAL ADJUSTMENTS THAT HAVE BEEN OBTAINED IN ACCORDANCE WITH THE CURRENT EDITION OF THE NEBB PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND BALANCING OF ENVIRONMENTAL SYSTEMS. ANY VARIANCES FROM DESIGN QUANTITIES, WHICH EXCEED NEBB TOLERANCES, ARE NOTED IN THE TEST - ADJUST - BALANCE REPORT PROJECT SUMMARY. NEBB TAB FIRM: REG. NO. 3000 AIRTEST Co • Inc CERTIFICATION Aviation Partners Boeing AIRTEST CO., INC. SUBMITTED & CERTIFIED BY: NEBB TAB FIRM: AIRTEST CO., INC. TAB SUPERVISOR: MIKE TOUCHETTE REG. NO. 3000 SIGNATURE: CERTIFIED BY: MIKE TOUCHETTE DATE: CERTIFICATION EXPIRATION DATE: March 31, 2011 P.O. Box 86 • Issaquah, Washington 98027 • (425) 313 -0172 • Fax (425) 313 -5735 2 of 8 NEBB Cert. No. Nerertifitatthu THIS IS TO CERTIFY THAT .UR'`ES' Company, Inc. in Issaquah, 1.91 HAS MET ALL REQUIREMENTS FOR RENEWAL OF NEBB CERTIFICATION IN THE FOLLOWING DISCIPLINE Exp. 1Vlarc,h 31, 2011 9LIRTIST Company, Inc./WA No.3000 Ail & St: yd�on� S ystems FOR THE BOARD OF DIRECTORS: President President -Elect Exp. March 31, 2011 'UR:VEST Company, lnc./14 No. 3000 NEBB Cert. No. 1icertiftcati n u THIS IS TO CERTIFY THAT _Mike T ©uchette with . tI .TEST `Company, Inc. in Issaquah, W.9t HAS MET ALL THE NEBB REQUIREMENTS FOR NEBB CERTIFIED PROFESSIONAL STATUS IN MyChOniCS Systems FOR THE BOARD OF DIRECTORS: President ['resident -Elect . .'INSTRUMENT / SERIAL`NUMBER`f " . ' APPLICATION , ‘ . ..DATES OF USE 4.; CALIBRATION '` TEST DATE PACER DA400 / 1014074 Velocity Sep -09 9/09 Alnor Balometer 6461 / 70634370 CFM Sep -09 9/09 Alnor EBT -720 / 90634004 Pressure Sep -09 9/09 SHIMPO DT207L -S12 / D07BB0023 RPM Sep-09 9/09 VOM, Fluke T5 -600 / 95390345 Electrical Sep -09 9/09 Alnor HM670 / 70748151 Hydronics Sep-09 9/09 AIRTEST Co.. Inc. Calibration Report PROJECT: Aviation Partners Boeing LOCATION: Tukwila, WA PROJECT #: 09- 9053 -1 DATE: 9/22/2009 TECHNICIAN: Scott Davies SYMBOLS &ABBREVIATIONS • ADJ = Adjustable Fan Speed CD = Ceiling Diffuser CFM = Cubic Feet per Minute D/A = VAV Inlet Dimension in Inches DD = Design Data EG = Exhaust Grille E.S.P. = External Static Pressure F/C = VAV Calibration Factor FCD = Field Collected Data FG = Floor Grille FLA = Motor Full Load Amps GPM = Gallons per Minute HP = Horsepower Hz = Hertz in. Hg. = Inches Mercury in. w.g. = Inches Water Gauge LD = Linear Diffuser LD x = Linear Diffuser where "x" is number of slots N/A = Not Available NI = Not Installed NR = Not Required NPSH = Net Positive Suction Head RG = Return Grille RPM = Revolutions per Minute SF = Motor Service Factor S.P. = Static Pressure SWG = Side Wall Grille T.S.P. = Total Static Pressure VAR = Variable Fan Speed 5 of 8 System / Unit Area Served VAV Type VAV Address Box Inlet Size K Factor Heat Works Outlet Type Size LW/ ! D Design CFM Fan Speed Final Reading . % Final Deviation SA -01 Office CD 10 RD 250 240 96.00 SA -02 Office CD 10 RD 250 260 104.00 Totais:' ' , 500, a 500. a 100 % ,... Al '! 1a: T co. TnC. Air Handling Unit Report PROJECT: Aviation Partners Boeing LOCATION: Tukwila, WA PROJECT #: 09- 9053 -1 SYSTEM /UNIT: AHU -01 AREA: * Notes SYSTEM /UNIT: AHU -01 / VAV -01 AREA: Offices AHU -01 / VAV -01 Supply Outlet Summary * Notes Airtest Co Inc DATE: 9/22/2009 CONTACT: Scott Davies Tested By: Mike Kehoe Test Date: September 14, 2009 Tested By: Scott Davies Test Date: September 22, 2009 Air Test Data Des. Fan /Heat CFM 500 CFM Act. Fan /Heat CFM 500 CFM Design Primary Max CFM 500 CFM Actual Max Primary CFM 510 CFM Design Primary Min. CFM 250 CFM Actual Primary Min. CFM 250 CFM 6 of 8 Unit Data VAV Type VAV Address Box Inlet Size K Factor Heat Works Series VAV -01 8 RD 525 Yes Test Data Fan Speed ADJ. Al '! 1a: T co. TnC. Air Handling Unit Report PROJECT: Aviation Partners Boeing LOCATION: Tukwila, WA PROJECT #: 09- 9053 -1 SYSTEM /UNIT: AHU -01 AREA: * Notes SYSTEM /UNIT: AHU -01 / VAV -01 AREA: Offices AHU -01 / VAV -01 Supply Outlet Summary * Notes Airtest Co Inc DATE: 9/22/2009 CONTACT: Scott Davies Tested By: Mike Kehoe Test Date: September 14, 2009 Tested By: Scott Davies Test Date: September 22, 2009 Air Test Data Des. Fan /Heat CFM 500 CFM Act. Fan /Heat CFM 500 CFM Design Primary Max CFM 500 CFM Actual Max Primary CFM 510 CFM Design Primary Min. CFM 250 CFM Actual Primary Min. CFM 250 CFM 6 of 8 System / Unit Area Served Outlet Type Size LxW / D Design CFM Final Reading % Final Deviation SA -01 Office CD 10 RD 250 260 104.00 SA -02 Office CD 10 RD 250 260 104.00 Totals': - 500 `.` 520 104 %; ' e Unit Data ` ; ` a , _ VAV Type VAV Address Box Inlet Size K Factor Heat Works Series VAV -02 8 RD 750 Yes ' "' Design CFM Test Data Fan Speed ADJ. System / Unit- Unit Data VAV Type VAV Address Box Inlet Size K Factor Heat Works Series VAV -03 8 901 Yes ' "' Design CFM Test Fan Speed ADJ. @ MIN. System / Unit- Area Served Outlet Type' ' LxW ! D ' "' Design CFM Final Reading % Final Deviation SA -01 Office CD 10 320 350 109.38 Totals : - - 320 ." "350 109 % AIR •ES .L Co. Enc. Air Handling Unit Report PROJECT: Aviation Partners Boeing LOCATION: Tukwila, WA PROJECT #: 09- 9053 -1 SYSTEM /UNIT: AHU -01 / VAV -02 AREA: Office AHU -01 / VAV -02 Supply Outlet Summary * Notes SYSTEM /UNIT: AHU -01 / VAV -03 AREA: Office AHU-01 / VAV -03 Supply Outlet Summary * Notes Airiest Co Inc DATE: 9/22/2009 CONTACT: Scott Davies Tested By: Scott Davies Test Date: September 22, 2009 Air. Test Data Des. Fan /Heat CFM 500 CFM Act. Fan /Heat CFM 520 CFM Design Primary Max CFM 500 CFM Actual Max Primary CFM 490 CFM Design Primary Min. CFM 250 CFM Actual Primary Min. CFM 240 CFM Tested By: Mike Kehoe Test Date: September 22, 2009 Air Test Data Des. Fan /Heat CFM 320 CFM Act. Fan /Heat CFM 350 CFM Design Primary Max CFM 320 CFM Actual Max Primary CFM 325 CFM Design Primary Min. CFM 160 CFM Actual Primary Min. CFM 165 CFM 7 of 8 System /Unit Area Served Outlet Type Size LxW / D Design CFM Final Reading % Final - Deviation SA -01 Office CD 10 RD 265 310 116.98 SA -02 Office CD 10 RD 265 300 113.21 SA -03 Open Office CD 10 RD 270 300 111.11 Totals : - - 800 910 114 % System /.Unit = Area Served Outlet Type Size LxW / D Design CFM Final Reading % Final Deviation SA -01 Office CD 10 320 290 90.63 SA -02 Office CD 10 320 300 93.75 Totals : - - 640 590 - 92 % AIR i "l - T Co, Ti c Air Handling Unit Report PROJECT: Aviation Partners Boeing LOCATION: Tukwila, WA PROJECT #: 09- 9053 -1 SYSTEM /UNIT: AHU -01 / VAV -03 (Existing) AREA: Offices AHU -01 / VAV -03 (Existing) Supply Outlet Summary * Notes AHU -01 / VAV -03 (Existing) 22- Sep -09 Scott Davies The fan speed and heat control box has a loud electrical hum. SYSTEM /UNIT: AHU -01 / VAV -04 (Existing) AREA: Office AHU -01 / VAV -04 (Existing) Supply Outlet Summary DATE: 9/22/2009 CONTACT: Scott Davies Tested By: Scott Davies Test Date: September 22, 2009 Air Test Data Des. Fan /Heat CFM 800 CFM Act. Fan /Heat CFM 910 CFM Design Primary Max CFM 800 CFM Actual Max Primary CFM 800 CFM Design Primary Min. CFM 150 CFM Actual Primary Min. CFM 145 CFM Tested By: Scott Davies Test Date: September 22, 2009 Air Test Data Des. Fan /Heat CFM 640 CFM Act. Fan /Heat CFM 610 CFM Design Primary Max CFM 640 CFM Actual Max Primary CFM 600 CFM Design Primary Min. CFM 320 CFM Actual Primary Min. CFM 330 CFM * Notes Attest Co Inc 8 of 8 ' , Unit Data . VAV Type VAV Address Box Inlet Size K Factor Heat Works Series VAV -03 14 RD 2750 Yes Test Data Fan Speed Low /ADJ. @ MIN. AIR i "l - T Co, Ti c Air Handling Unit Report PROJECT: Aviation Partners Boeing LOCATION: Tukwila, WA PROJECT #: 09- 9053 -1 SYSTEM /UNIT: AHU -01 / VAV -03 (Existing) AREA: Offices AHU -01 / VAV -03 (Existing) Supply Outlet Summary * Notes AHU -01 / VAV -03 (Existing) 22- Sep -09 Scott Davies The fan speed and heat control box has a loud electrical hum. SYSTEM /UNIT: AHU -01 / VAV -04 (Existing) AREA: Office AHU -01 / VAV -04 (Existing) Supply Outlet Summary DATE: 9/22/2009 CONTACT: Scott Davies Tested By: Scott Davies Test Date: September 22, 2009 Air Test Data Des. Fan /Heat CFM 800 CFM Act. Fan /Heat CFM 910 CFM Design Primary Max CFM 800 CFM Actual Max Primary CFM 800 CFM Design Primary Min. CFM 150 CFM Actual Primary Min. CFM 145 CFM Tested By: Scott Davies Test Date: September 22, 2009 Air Test Data Des. Fan /Heat CFM 640 CFM Act. Fan /Heat CFM 610 CFM Design Primary Max CFM 640 CFM Actual Max Primary CFM 600 CFM Design Primary Min. CFM 320 CFM Actual Primary Min. CFM 330 CFM * Notes Attest Co Inc 8 of 8 Unit Data' VAV Type VAV Address Box Inlet Size K Factor Heat Works Series VAV -04 14 RD 2650 Yes Test Data Fan Speed Medium + reastat AIR i "l - T Co, Ti c Air Handling Unit Report PROJECT: Aviation Partners Boeing LOCATION: Tukwila, WA PROJECT #: 09- 9053 -1 SYSTEM /UNIT: AHU -01 / VAV -03 (Existing) AREA: Offices AHU -01 / VAV -03 (Existing) Supply Outlet Summary * Notes AHU -01 / VAV -03 (Existing) 22- Sep -09 Scott Davies The fan speed and heat control box has a loud electrical hum. SYSTEM /UNIT: AHU -01 / VAV -04 (Existing) AREA: Office AHU -01 / VAV -04 (Existing) Supply Outlet Summary DATE: 9/22/2009 CONTACT: Scott Davies Tested By: Scott Davies Test Date: September 22, 2009 Air Test Data Des. Fan /Heat CFM 800 CFM Act. Fan /Heat CFM 910 CFM Design Primary Max CFM 800 CFM Actual Max Primary CFM 800 CFM Design Primary Min. CFM 150 CFM Actual Primary Min. CFM 145 CFM Tested By: Scott Davies Test Date: September 22, 2009 Air Test Data Des. Fan /Heat CFM 640 CFM Act. Fan /Heat CFM 610 CFM Design Primary Max CFM 640 CFM Actual Max Primary CFM 600 CFM Design Primary Min. CFM 320 CFM Actual Primary Min. CFM 330 CFM * Notes Attest Co Inc 8 of 8 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 FIRST MERCURY INS CO FMWA0000042 01/10/2009 01/10/2010 $1,000,000.00 01/09/2009 2 FIRST MERCURY INS CO FMWA000004 01/10/2008 01/10/2009 $l,000,000.000111412008 1 CAPITOL SPECIALTY INS CORP CS00335826 01/10/2007 01/10/2008 $1,000,000.00 01/29/2007 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SG7910 01/10/2007 Until Cancelled $6,000.00 01/29/2007 Name Role Effective Date Expiration Date D/B SOLUTIONS, LLC PARTNER /MEMBER 01/12/2007 Untitled Page General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company D/B SOLUTIONS LLC 4257374042 10627 90TH STREET NE LAKE STEVENS WA 98258 SNOHOMISH Limited Liability Company D/B SOLUTIONS NORTHWEST, LLC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602667064 ACTIVE DBSOLSL934BK CONSTRUCTION CONTRACTOR 1/29/2007 1/29/2011 SHEET METAL UNUSED Business Owner Information Bond Information Insurance Information • 0 Page 1 of 1 https://fortress.wa.gov/lni/bbip/Detail.aspx 08/07/2009