Loading...
HomeMy WebLinkAboutPermit M09-144 - COMMITTEE FOR A BETTER KING COUNTYThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M09 -144 Committee for a Better King County 3415 South 116th Street RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION F,age # Code Exemption � � �� Brief Explsnatoty Description, Statute /Rule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 21 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. COMMITTEE FOR A BETTER KING COUNTY 3415 S 116 ST EXPIRED 07 -I9 -10 M09 -144 Parcel No.: 1023049043 Address: Suite No: 3415S116STTUKW Tenant: Name: COMMITTEE FOR A BETTER KING COUNTY Address: 3415 S 116 ST , TUKWILA WA Owner: Name: TTA/E PROPERTY TAX DEPT 207 Address: PO BOX 4900 , SCOTTSDALE AZ Contact Person: Name: TERRY COURSE Address: 899 WEST MAIN , AUBURN WA Contractor: Name: IECS INC. Address: P.O. BOX 19252 , SEATTLE, WA Contractor License No: IECS * * *044QL DESCRIPTION OF WORK: PROVIDE EXHAUST FAN FOR VEHICLE STORAGE Value of Mechanical: $5,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial /Industrial doc: IMC -10/06 Citylkf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /wwwci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 1 0 0 0 * *continued on next page ** M09 -144 Permit Number: M09 -144 Issue Date: 11/25/2009 Permit Expires On: 05/24/2010 Phone: Phone: 253 - 939 -9495 Phone: 206 939 -9495 Expiration Date: 11/20/2010 Fees Collected: $230.71 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 11 -25 -2009 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied The granting of this permit does not pre construction or the perfony}ance of work. doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M09 -144 Issue Date: 11/25/2009 Permit Expires On: 05/24/2010 Date: 11 K1, ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit. Date: /1)e U r 2 5 'Y Signature: Print Name: IAA This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -144 Printed: 11 -25 -2009 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 1023049043 Permit Number: M09 -144 Address: 3415 S 116 ST TURIN Status: ISSUED Suite No: Applied Date: 11/10/2009 Tenant: COMMITTEE FOR A BETTER KING COUNTY Issue Date: 11/25/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 9: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M09 -144 Printed: 11 -25 -2009 • i City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: I Print Name: doc: Cond -10/06 Date:104% Z 2c)o M09 -144 Printed: 11 -25 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 h ttp: / /www. ci. t ukwi l a. wa. us SITE LOCATION Site Address: 3415 S 116TH . Tenant Name: Name: TERRY COURSE COMMITTEE FOR A BETTER KING CO. Mailing Address: 899 west main Auburn wa. E -Mail Address: seattl emechanical@msn. com Contact Person: E -Mail Address: Q:t Applications Worms-Applications On Line\3 -2006 - Pernik Application.doc Revised: 9 -2006 bh Building Permit No. Mechanical Permit No. M — J __ Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) - Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 000480003 IN- 0 1 - qo 2- 1 , 3 Suite Number: 109 Floor: Property Owners Name: RREEF PROPERTY MGMT. Mailing Address: 12720 GATEWAY DRIVE, SUITE 200 TUKWILA WA. 98168 City New Tenant: © Yes .. No State C ONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: 2 5 3- 9 3 9 - 9 4 9 5 City State Fax Number: 253- 939 -9260 •GENERAL CONTRACTOR INFORMATION – .(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: State City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: State Zip Zip Zip Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System 1 Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm /Ind Contact Person: TERRY COURSE MECHANICAL PERMIT INFORMATION - 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: IECS INC Mailing Address: 899 WEST MAIN AUBURN WA. 98001 City State Zip Day Telephone: 253 - 939 -9495 E -Mail Address: SEATTLE MEHCANICAL Fax Number: 253-939-9260 Contractor Registration Number: IECS * * * 044QL Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 5, 000 Scope of Work (please provide detailed information): PROVIDE EXHAUST FAN FOR VEHICLE STORAGE. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ....13 Replacement .... ❑ 11 /13/0/ Fuel Type: Electric ❑ Gas....® Other: Indicate type of mechanical work being installed and the quantity below: Q: Wpplications\Fonns- Applications On Line a -2006 - Permit Application.doc Revised: 9-2006 bh Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Mailing Address: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN AU ZED AGENT: / Signature: Date: /(' C ' ` ,. Print Name: nit (k ` - e ( k Day Telephone: 7 C,--'-'sE Y14cs j l/JhCt /l 1 J v u Date Application Expires: 6 O- o Date Application Accepted: h- -to-©9 Q:'Applications \Forms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh City State Staff Initials: Zip Page 6 of 6 Receipt No.: R09 -01782 Payee: IECS INC ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 45211 230.71 Authorization No. RECEIPT Parcel No.: 1023049043 Permit Number: M09 -144 Address: 3415 S 116 ST TUKW Status: PENDING Suite No: Applied Date: 11/10/2009 Applicant: COMMITTEE FOR A BETTER KING COUNTY Issue Date: Payment Amount: $230.71 Initials: WER Payment Date: 11/10/2009 01:15 PM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000.322.102.00.00 184.57 000.345.830 46.14 Total: $230.71 PAYMENT RECEIVE doc: Receiot -06 Printed: 11 -10 -2009 COMMENTS: Type of Inspection: //N6 O) /4/r� lcAi4t Address: 3y/5' S //G sT ,.. , (16 -: \ rte p:../ e_1.i!'r: A e Special Instructions: o 1 er A ; 7 1 rd i" 1 - r 1 4 0 C . 1 J- ! J � I.-� s 4 A df r j 7--,> c Avit . t•`. � i /l r , OC fir rA- frt /t A ( b / - ? - .A ,1 I 1-'t JL I'r ` €-c.I ^ r` A- A liJ, Project: Oa /17/rn TE 6 Fo' ?4,t3Err'4 Type of Inspection: //N6 O) /4/r� lcAi4t Address: 3y/5' S //G sT Date Called: Special Instructions: o Date Wanted: /— 20 -- /0 6,03.. p.m. Requester: Phone No: v?oG - -5 ad C /7709-#/y INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ‘` 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. (206)431 -3670 or� ns required prior to approval. ri $60.00 REINSPECTION FEE R QUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: i SC) y11U1 COOK PROJECT: CONTRACTOR: SUBMITTED BY: PHONE: FAX: E -MAIL: DATE: KING COUNTY MO' ILt SEATTLE MECHANICAL BOB MOFFITT Air Commodities 6100 Sixth Ave S Seattle 206 - 767 -2600 206 - 7676 -4815 bobm @air - commoditites.com 9/8/2009 LOREN COOK COMPANY SUBMITTAL Corporate Offices: 2015 E. Dale Street, Springfield, MO 65803 • P.O. Box 4047, Springfield, MO 65808 417.869.6474 • fax 417.869.2520 lorencook.com Pe nn LE A r ^ � r � �1 r h � O• A � PA ` w, a 1rnfIn/ it. p Ncyt REVIEWED FO CODE COMPLIANCE APPROVED NOV 17 2009 City of Tukwila BUILDING DIVISIM RECEIVED NOV 1 PERMIT CENTER A 4 -3/4 B 43 -5/8 C 37 -1/4 G 3 TSq. 30 Roof Open.Sq.* 25 -1/2 1 2 3 4 5 6 7 8 LwA dBA Sones 84 86 87 81 76 73 66 60 83 72 21 HP RPM Volts /Ph /Hz Enclosure Mounted 1 -1/2 1725 460/3/60 ODP -SE Yes Qty Catalog Number Flow (CFM) SP (inwc) Fan RPM Power* (HP) 1 21008B 6000 .150 1053 1.39 COCK ACE -B Downblast Centrifugal Exhaust Ventilator Roof Mounted /Belt Drive STANDARD CONSTRUCTION FEATURES: All aluminum housing - Backward inclined all aluminum wheel - Two piece top cap with stainless steel quick release latches - Welded curb cap corners - Birdscreen - Vibration isolators - Lifting Lugs - Permanently lubricated ball bearing motors - Static resistant belts - Adjustable pitch drives through 5 hp motor - Corrosion resistant fasteners - Regreasable bearings in a cast iron pillow block housing, rated at 200,000 hours average life - All fans factory adjusted to specified fan RPM - Transit tested packaging - Standard motors ship factory installed. Performance (•Bhp includes 8% drive loss) Altitude (ft): 400 Temperature (F): 70 Motor Information Motor efficiency meets EPACT requirements Sound Data Inlet Sound Power by Octave Band Accessories: STD DISCONNECT BD -24 DAMPER ROOF CURB RCG 28 -13.5H W/TRAY v5.6.103.10809 Fan Curve Legend CFM vs SP CFM vs HP Point of Operation System Curve 0 c C) us 1.40 v 1.05 C a- CO 0.70 Dimensions (inches) NOTE: Accessories may affect dimensions shown. 'Shipping Weight(lbs)***283 ( Roof opening size for curbs supplied by Coo only. — Includes fan, motor 8 accessories. Fan Curve 1.75 0.35 0.00 MINI MARK: EF -1 PROJECT: KING COUNTY DATE: 9/8/2009 TS f 0 1500 3000 4500 6000 Flow (CFM) 7500 2.00 1.60 1.20 0 lD .800 o .400 0.00 Throat Width 24 Throat Length 48 Hood Width 35.75 Hood Length 59.75 Height 23 A 2.75 Free Area(Sq.ft) 14.85 THE v5.6.103.10809 CiOK Extruded Relief or Intake Ventilator STANDARD CONSTRUCTION FEATURES: Heavy gauge all aluminum construction - Birdscreen - Solid welded and mitered tier corners with a built in rain catch on each tier - Built in water trough - Welded curb cap corners - Anti - condensate coating on underneath side of topcap - Five year warranty. Performance (Intake Accessories: BDI 25.5X49.5(THROAT MOUNTED) ROOF CURB RCG 28X 52 -13.5H W/TRAY Hood Width Qty 0 Catalog Number 24X48X6TRE Flow (CFM) 6000 II I- �i'I_ Altitude (ft): 400 Temperature aIr4s Height MARK: RI -1 PROJECT: KING COUNTY DATE: 9/8/2009 Hood Length Throat Width A ._ A Throat Length Dimensions (inches) NOTE: Accessories may affect dimensions shown. 'Shipping Weight(Ibs) * ** 295 , Includes accessones. Mark Qty Description A Max. B C Sq. # Panels EF -1 1 BD -24 DAMPER 5 -3/16 1 -7/8 23 -3/4 1 BD COOK Gravity Backdraft Damper STANDARD CONSTRUCTION FEATURES: .02 Aluminum blades - .06 aluminum frame - Aluminum hinge pins - Nylon bushings. Dimensions (inches) v5.6.103.10809 A PROJECT: KING COUNTY DATE: 9/8/2009 Air Flow Mark Qty Descriptio n Ht Options* A F Sq. V Sq. W Sq. Roof Opening EF -1 1 RCG 28 13.5 2 1 -1/2 28 -1/2 32 -1/2 21 -3/4 25 -1/2 COOK RCG Galvanized Steel Roof Curb STANDARD CONSTRUCTION FEATURES: 18 gauge galvanized steel - 1-1/2", 3 lbs. density thermal and acoustical insulation - Continuously welded corners - Wood nailer. Options:(As noted below *) 1) No wood nailer (deduct 1 -1/2" for actual height). 2) Damper tray. Dimensions (inches) v5.6.103.10809 C Wood Nailer PROJECT: KING COUNTY DATE: 9/8/2009 V Sq. F Sq. Insulation Fes- W Sq. Roof Opening A it. Optional Damper Tray Mark Qty Description A B Max. C D E F RI -1 1 BDI 25.5X49.5(THROAT 6 5.1875 25.5 49.5 1.875 .125 BDI COOK Intake Backdraft Damper STANDARD CONSTRUCTION FEATURES: .020 aluminum blades - .060 aluminum frame - .080 aluminum wrapper - Spring return to close - Aluminum hinge pins - Brass bushings. NOTES: Maximum operating temperature: 200 deg. F (95 deg. C). Dimensions (inches) v5.6.103.10809 F Ref. E L Cxf , FRef. PROJECT: KING COUNTY DATE: 91812009 Max. Mark Qty Description Ht Options* A B C E F Roof Opening RI -1 1 RCG 28X 52 13.5 2 2 1.5 1.875 28 52 25 X 49 RCG Dimensions (inches) v5.6.103.10809 COOK Galvanized Steel STANDARD CONSTRUCTION FEATURES: 18 ga. galvanized steel - 1-1/2"(3.81 cm), 3 lbs. /cu.ft.(1.36 kg /cu. meter) density thermal and accoustical insulation - Continuously welded corners - Wood nailer. Options:(As noted below *) 1) No wood nailer 2) Damper tray Note: Roof Opening is (E - 3) X (F - 3) Wood Nailer PROJECT: KING COUNTY DATE: 9/8/2009 TERRY COURSE 899 WEST MAN AUBURN WA 98001 RE: Permit No. M09 -144 3415 S 116 ST TUKW Dear Permit Holder: Sincerely, -or- Bill Rambo Permit Technician File: Permit File No. M09 -144 City of 7 ° r s'::. ila Department of Community evelopment Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 07/19/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. Jim Haggerton, Mayor In the event you do not call for an inspection and /or receive an extension prior to 07/19/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. -- 6L1N,„1, 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 o Phone: 206- 431 -3670 o Fax: 206 - 431 -3665 ACTIVITY NUMBER: M09 -144 DATE: 11 -10 -09 PROJECT NAME: COMMITTEE FOR A BETTER KING COUNTY SITE ADDRESS: 3415 S 116 ST X Original Plan Submittal Response to Correction Letter # _ Response to Incomplete Letter # Revision # After Permit Issued DEPART ENTS: io Bu Idin Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-12-09 Complete Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route 116, Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents /routing slip.doc 2 -28 -02 • PE T PLAN REVIEW /ROUTING SLIP � �i glk Fire revention Structural C �II n Permit Coordinator No further Review Required DATE: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: Planning Division Not Applicable n n DUE DATE: 12 -10 -09 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Assignment of Type Specialty 1 Specialty 2 Effective Date Expiration Date Status Savings Savings Account Effective Date Release Date Assignment Type Impaired Date Amount Received Date $1,000,000.0007 Number 10 FEDERAL MUTUAL INS 9821065 08/01/200708/01 /2009 2 10/10/1996 3/4/2009 Bond $4,000.00 License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SEATTM1038NR SEATTLE MECHANICAL INC CONSTRUCTION CONTRACTOR UNUSED SHEET METAL 8/19/199711/4/2001 ARCHIVED Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 11 LIBERTY NORTHWEST INS CORP BKW1053913555 08/01/2009 08/01/2010 $1,000,000.0007 /21 /2009 10 FEDERAL MUTUAL INS 9821065 08/01/200708/01 /2009 $1,000,000.0006 /26/2008 Untitled Page • • General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company IECS INC 2064694153 PO BOX 19252 SEATTLE WA 981091252 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601639846 ACTIVE IECS * * *044QL CONSTRUCTION CONTRACTOR 11/13/1996 11/20/2010 HTG /VENT /AIR CONDITIONING UNUSED Other Associated Licenses Business Owner Information Name HUMPHREY, GEORGE Role Effective Date 01/01/1980 Expiration Date Assignment of Savings Information Insurance Information https://fortress.wa.gov/lni/bbip/Detail.aspx Page 1 of 2 11/25/2009 v C T MAP N.T.S. -11- N O R T H S T MAP N.T.S. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEVVVED FOR CODE COMPLIANCE APPROVED NOV 17 2009 City of Ha BUILDING VISION ENERGY CODE NOTES 1) HEAT IS VIA', GAS, NO ELECTRIC HEAT ALLOWED -NO CHANGE TO ENVELOPE 2) PROVIDE VAPOR ON ALL WALL TO THE WARM SIDE 3) CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES INCLUDING WEATHER- STRIPPING AT ALL EXTERIOR DOORS. 4 MAXIMUM ALLOWABLE LOAD FOR SWITCH IS 80% OF 20 AMP CIRCUIT. 5) PROVIDE DUAL LEVEL SWITCHING IN ALL ROOMS ADJACENT TO EXTERIOR WINDOWS BUILJI \G & SITE STATISTICS TAX PARCEL NUMBER: BUILDING CODE: TENENT AREA: CONSTRUCTION: OCCUPANCY GROUP: ZONE: AREA OF WORK: - BUILDING AREA TOTAL BUILDING AREA= 27,750 S.F. - TENANT AREA AFTER IMPROVEMENTS: SUITE 109 OFFICE = 3,838 S.F. WAREHOUSE= 4,000 S.F. 1023049043 2006 IBC W/ WA STATE AMENDMENTS SUITE 109 8,000 S.F. V -B FULLY SPRINKLED RED B OFFICE; S -1 STOR. C /LI (COMMERCIAL / LIGHT INDUSTRIAL) 1,100 S.F. TOTAL= 7,838 S.F. - OCCUPANT LOAD: SUITE OFFICE= 3,838 S.F. / 100= 38 OCC. (1 EXIT- TRAVEL DISTANCE) WAREHOUSE 4,000 S.F. / 500= 8 (1 EXIT) TOTAL= 46 OCCUPANTS SCOPE OF WORK: INSTALLING NEW EXHAUST FAN FOR VEHICLE STORAGE IN WAREHOUSE. LEGAL DESCRIPTION 102304 43 LOT 2 OF CITY OF TUKWILA SHORT PLAT NO 90 -2 -SS RECORDING NO 9003121482 SD SHORT PLAT DAF - POR OF GOV LOT 3 & OF SE 1/4 OF NE 1/4 OF SEC 09 -23 -04 TGW POR OF GOV LOT 6 & OF SW 1/4 OF IOW 1/4 OF SECTION 10 -23 -04 - BAAP 70 FT RGT OF ENGR STA H 556 +57,3 BEING A PT ON NELY MGN SHEET 1 OF 7 FOR R/W SR 99 S 118TH ST TO JUNCTION SSH NO 1 -K APPROVED JULY 23, 1957 SD PT BEING PT OF TANGENCY OF CURVE THRU POINT BEARING N 42 -02 -03 E 748,51 FT TH SELY ALG SD MGN & SAID CURVE THRU C/A OF 04 -26 -56 ARC DISTANCE OF 58,12 FT TH N 41- 57 -.30'" E 499,81 FT TH N 15 -27 -21 E 75,56 FT TO PUB TH S 74 -32 -39 E 212,89 FT TH S 78 -39 -54 E 128,28 FT TH S 81 -20 -44 E 447,24 FT TAP OF CURVE CCNC -AVE TO N TH ELY ALG SD CURVE RAD OF 170 FT THRU C/A OF 15-51-28 'ARC DIST OF 47.05 FT TH N 82 -47 -48 E 101,13 FT TO WLY MGN OF FOR OF SECTION 9 CONDEMNED IN SUPERIOR COURT CAUSE NO 646697 TH S 07 -08 -23 E 544.81 FT ALONG WESTERLY MARGIN TO A LN 60 FT N OF & PLW ENGR B -LINE AS SHOWN ON SHEET 1 OF 7 FOR R/W SR 99 SOUTH 118TH ST TO JUNCTION SSH 1 -K APPROVED JULY 23, 1957 TH N 88 -10 -42 W 630,87 FT TAP 60 FT RGT OF ENGR STA B 548 +00 SAID R/W PLANS TH N 79 -41 -19 W 359,21 FT TAP 70 FT RGT OF ENGR STA H 551 +64,4 SD PT ALSO BEING PT OF CUVE CONCAVE TO NORTH RAD PT BEARING N 10 -18 -41 E 748.51 FT TH NWLY ALG SD CURVE THRU C/A OF 30 -03 -04 ARC DISTANCE OF 392,59 FT TH N 41 -57 -30 E 499,81 FT TH N 15 -27 -21 E 75,56 FT TO PUB SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electrical Plumbing Gas Piping City of Tukwila El `'NG DIVISION JUL !19 2010 FILE COPY Permit No. MO 1— [41-{ Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By Date: "'IOU z c- aoc ? City Of Tukwila BUILDING DIVISION RECEIVED NOV 10.2009 PERMIT CENTER Mo9 ILIL.I 0 Will 0 fIL CIL r an Lim 00 0 CNI II 0 r CHECKED BY um a DESCRIPTION 00 0 0 r rim 00 0 OM CO OM OM 11 11 OM OM 0) OD w 0 z Z 0 Z® l— w tli <01 (f) (Do o 0 z I BUILDING ENVELOPE, ENTIRE SPACE IS HEATED AND COOLED USED NO CHANGES TO WALLS, DOORS OR LIGHTING / / 24' -6" 73' -6" / 24' -6" 24' -6" 2mitt -'1 7 -" ,/P r r EX. SUSPENDED CEILING GRID AND LIGHTS NO CHANGES NOTE: '(SEE T -1) 1. PROVIDE MECHANICAL VENTILATION EXPOSED TO VEHICLE EXHAUST PER IMC 2006 SECTION 404. MINIMUM 0.05 CFM /S.F. & MAXIMUM 1.5 CFM /S.F. TOTAL WAREHOUSE AREA 4000 S.F. . TOTAL CFM OF EXHAUST FAN 6000 CFM.. 2. MECHANICAL VENTILATION SYSTEM TO OPERATE AUTOMATICAL UPON DETECTION OF VEHICLE OPERTION OR PERSONEL OCCUPANCY V EX. OFFICE EX. OFFICE EX. OFFICE 3. CO DETECTOR SHALL OPERATE EF -1 UPON DECTECTION OF CO LEVEL AT 35 PPM OR GREATER. 4. OFFlCE SPACES TO HAVE POSITIVE PRESSURE. 1 TRAVEL DIST. 75 LF EX. OFFICE 0 EX. OFFICE EX. OFFICE 0 EX. HC 0I R EX. OFFICE EVIEWED FOR CODE COMPLIANCE PENWRI) NQ / 17 ZUU9 City of Tukwila BUILDING nnnmlnhi OPEI OFFICE BREAK 0 HWR RELIEF HOOD ON EXISTING SUSP. CEILING GRID AND LIGIF MTH BAROMETRIC DAMPER 36 "0 DUCT DOWN TO 12" OFF FLOOR_ CHANGE USE FROM WAREHOUSE (S1) TO CLOSED PARKING GARAGE (S2) PROVIDE MECHANICAL VENTILATION (SEE MECHANICAL NOTES) RELIEF HOOD ON ROOF WITH BAROMETRIC DAMPER WAREHOUSE 36"0 DUCT DOWN TO 12 OFF FLOOR_ 6�, " �a S V) w hCD Z It 03 rm 001 ‹0 4 _ C III 0 EF -1 ON ROOF EF -1 ON ROOF Equipment Schedule (new) COOK ACE -B CFM 1 V /Ph 6000 1 208/1 CO DETECTOR EX. EXPOSED STRUCTURE AND LIGHTS ADD MECHANICAL VENTILATION FOR VEHICLE STORAGE 60001 NA EF -1 CONTROLED BY CO DETECTOR PROVIDE BAROMETRIC DAMPER WITH RI -1 SOUND RATTING UNIT WEIGHT 283 295 CO ® DETECTOR V v EXIT 1 REFLECTED CEILING PLAN SCALE: 1/8" = 1' -0" NORTH EXITING: FLOOR PLAN SCALE: 1/8" = 1' -0" RENTABLE SF. EXPANDED OFFICE OFFICE: 3,838 S.F. WAREHOUSE: 4,000 S.F. TOTAL : 8,000 S.F. v DRIVE IN DOOR *DOCK HIGH DOOR OFFICE: OCCUPANT LOAD IS 38, WITH COMMON PAT OF TRAVEL UNDER 100 LF (1014.3 EXCEPTION 1) , SINGLE EXIT PER 1015. PARKING GARAGE ALSO MEETS THE ABOVE. JUL ,I 2010 0 z F-i W (3) E- a H w a) 0 w O 0 o r-7-1 C11 CHANGE OF USE: CHANGE 4,162 SF OF WAREHOUSE TO 4,162 SF OF CLOSED PARKING GARAGE. RECEIVED NOV 10 2009 PERMIT CENTER