Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M09-145 - US BANK
US BANK 151 ANDOVER PK E EXPIRED OS -24 -10 M09 -145 Parcel No.: 0223100038 Address: Suite No: 151 ANDOVER PK E TUKW Tenant: Name: US BANK Address: 151 ANDOVER PK E , TUKWILA WA Owner: Name: U S BANK CORPORATE PROPS Address: 2800 E LAKE ST , LAKE0012 Contact Person: Name: JOFFRE SECHIER Address: 6802 S 220 ST , KENT WA Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P -105 , KENT, WA Contractor License No: COMFOMI015LA DESCRIPTION OF WORK: REPLACE (1) EXISTING 20 -TON ROOFTOP HEAT PUMP WITH (1) NEW 20 -TON ROOFTOP GAS PACKAGED AIR CONDITIONER Value of Mechanical: $28,500.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall /Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat /Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial /Industrial 0 doc: IMC -10/06 CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 - 2451 Web site: http: / /wwwci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND OUANTITY * *continued on next page ** M09 -145 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 251 -9840 Phone: 425 - 251 -9840 Expiration Date: 06/01/2010 M09 -145 11/25/2009 05/24/2010 Fees Collected: $521.11 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 11 -25 -2009 Permit Center Authorized Signature: I hereby certify that I have read and ex governing this work will be complied The granting construction Signature: Print Name: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us th, Permit Number: M09 -145 Issue Date: 11/25/2009 Permit Expires On: 05/24/2010 Date: 1 l [ K I'f l d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. this permit does not pres - - to give authority to violate or cancel the provisions of any other state or local laws regulating rformance of work. I am authorized to sign and obtain this mechanical permit. � II Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M09 -145 Printed: 11 -25 -2009 Parcel No.: 0223100038 Address: 151 ANDOVER PK E TUKW Suite No: Tenant: US BANK 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 11: ** *FIRE DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M09 -145 Status: ISSUED Applied Date: 11/12/2009 Issue Date: 11/25/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Readily accessible access to roof mounted equipment is required. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) doc: Cond -10/06 M09 -145 Printed: 11 -25 -2009 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M09 -145 Printed: 11 -25 -2009 Signature: Print Name: doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or e p rformance of work. '&,f4 Date: M09 -145 Printed: 11 -25 -2009 SITE LOCATION Site Address: 9S ` us Tenant Name: Property Owners Name: Mailing Address: 11Q0 CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Mailing Address: E -Mail Address: MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://Www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** wAA _ wk c a Cf3 IAQ. ew Contractor Registration Number: W © iS ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applications\Forms- Applications On Line \2009 Applications \1 -2009 - Mechanical Permit Application.doc Revised: 1 -2009 bh MECHANICAL PERMIT APPLICATION Mechanical Permit No. Project No. (For office use only) King Co Assessor's Tax No.: 000Z1 0 003 V Suite Number: Day Telephone: city Fax Number: New Tenant: Floor: ❑ Yes ErNo UL 98101 state zip 4s I -9 o1Jel ! V7 rp 9gii City State Q � Z / ip p Day Telephone: "� 1 Q 6 tb Fax Number: )— 7 � ' Expiration Date: CYO — %Do State City Day Telephone: Fax Number: Sta Zip Zip Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or addition to Heat/Refrig/Cooling System Incinerator — Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM I Incinerator — Comm/Ind Valuation of Project (contractor's bid price): $ ScRpe • f Work ( 1- ase provid detailed information): LL E iS "5° • v e CkLi BUILDING O R AUTHORIZED AGENT: S c Signature: (� Print Name: S1 Mailing Address: Visk)a 13 s4. Date Application Accepted: 111- [vat Date Application Expires: H:\Apphcations\Forms- Applicanons On Line \2009 Applications \ 1-2009 - Mechanical Permit Applicanon.doc Revised: 1-2009 bh Use: Residential: New ❑ Replacement 0, Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas ri Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: dc1V j ' d Oo 1 Day Telephone: " s) - 9 k6 L16 City State Zip oce(t7-I tio Staff Initials: 6 page 2 of 2 Parcel No.: 0223100038 Address: 151 ANDOVER PK E TUICW Suite No: Applicant: US BANK Receipt No.: Initials: User ID: R09 -01895 JEM 1165 Payment Credit Crd VISA - Authorization No. 115294 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payee: JOFFRE T SECHIER, COMFORT MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount RECEIPT 416.89 Payment Amount: $416.89 Account Code Current Pmts 000.322.102.00.00 416.89 Total: $416.89 Permit Number: M09 -145 Status: APPROVED Applied Date: 11/12/2009 Issue Date: Payment Date: 11/25/2009 09:50 AM Balance: $0.00 PAYMENT RECEIVED doc: Receipt -06 Printed: 11 -25 -2009 RECEIPT NO: R09 -01793 CM of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us Payment Date: 11/12/2009 User ID: 1165 Total Payment: 127.22 Initials: JEM Payee: COMFORT MECHANICAL, INC. SET ID: S000001321 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member M09 -145 PG09 -134 TOTAL: ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Amount 104.22 23.00 104.22 SET RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 13832 127.22 TOTAL: 127.22 Account Code Current Pmts 000.345.830 TOTAL: 127.22 127.22 PAYMENT RECEIVED Project Info Project Address US BANK Date 11/10/2009 151 ANDOVER PARK EAST For Building Department Use TUKWILA, WA 98188 Applicant Name: ,row SECHIER Applicant Address: 6802 S. 220TH ST, KENT, WA 98032 Applicant Phone: 425- 251 -9840 1 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms _.a. FILE COPY Revised July 2007 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 4 2009 City of Tukwila B UILDING DIVIRInN RECEIVED CITY OF TUKWILA NOV 12 2009 PERMIT CENTER MO HS Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location RTU -1 TRANE YFD241 265550 8000 ECONO 11 EER 11.30 ROOF 425- 251 -9840 Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM SP' HP /BHP Flow Control Location of Service Efficiency RTU -1 TRANE YFD241 324000 8000 ECONO 400000 324000 0.810 425- 251 -9840 Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency RTU -1 TRANE YFD241 324000 8000 ECONO 400000 324000 0.810 425- 251 -9840 Project Info Project Address US HANK Date 11/10/2009 151 ANDOVER PARK EAST For Building Dept. Use TUKWILA, WA 98188 Applicant Name: JOFFRE SECHIER Applicant Address: 6802 S. 220TH ST, KENT, WA 98032 Applicant Phone: 425- 251 -9840 Mechanical Summalry MECH -SU,M 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Includes Plans 2006 Washington State Nonresidential Energy Code Compliance Form Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Revised July 2007 REPLACE (1) EXISTING 20 -TON ROOFTOP HEAT PUMP WITH NEW 20 -TON ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT WITH ECONOMIZER. Compliance Option Qo Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14 -1A through 14 -1 G. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: -' Constant vol? ✓ Air cooled? ✓ Packaged sys? <20,000 Btuh? fl Split system? Economizer included? 4 If Heating Only: ❑ <5000 cfm? <70% outside air? Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ( START ) Heating Only No 2006 Washington State Nonresidential Energy Code Compliance Form Reference Section 1421 Yes — otal Ca.. wo economize <240,000 Btuh or 10 %? Heating /Cooling or Cooling Only Yes Reference Section 1423 Simple System Allowed (section 1420) Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical Permit Plans Checklist 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Project Address ns BANK Date 11/10/2009 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Ml n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls n.a. 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum M1 n. a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types M1 n. a . 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control n.a. 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule M1 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule Mi n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance yes 1413.3 Integrated operation Indicate capability for partial cooling M1 n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems n.a. 1414.1 Duct sealing Indicate sealing necessary n.a. 1414.2 Duct insulation Indicate R -value of insulation on duct n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan M1 n.a. 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training MS yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report Ml n.a. 1434 Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer Ml SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 1454 Pool covers Indicate vapor retardant cover 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form no is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper Is an acceptable alternative to a flue damper for fumaces where combustion air is drawn from the conditioned space. All fumaces with input ratings > 225,000 Btu /h (85 kW), including electric fumaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the Input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system Is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1438. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 85,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying ...:11. Cn..4h.. 4 A1"f Al 4 EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper Is an acceptable alternative to a flue damper for fumaces where combustion air is drawn from the conditioned space. All fumaces with input ratings > 225,000 Btu /h (85 kW), including electric fumaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the Input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system Is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1438. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 85,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying ...:11. Cn..4h.. 4 A1"f Al 4 VuualO III ilia Mal OlUI anu ICVCID IJOIUW Lila IIIbl Olul VI uuIM Il It O �••_• •••••_ _•_ __• _•r •• �_ "" "" "'a ..' ^..'.. p.. ••••• •••••!, • • three or more stories in he j6 Washington State Nonresidential Eher§retSilW ebttfonta or . ' 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum with Section 1412.4.1. start controls shall be designed to automatically adjust the start time of an HVAC Once outside air ducts meet the above listed requirements, any runs within system each day to bring the space to desired occupied temperature levels conditioned space shall comply with Table 14 -5 requirements. immediately before scheduled occupancy. The control algorithm shall, as a Other ducts and plenums shall be thermally insulated per Table 14 -5. minimum, be a function of the difference between space temperature and occupied Exceptions: setpoint and the amount of time prior to scheduled occupancy. 1. Within the HVAC equipment. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- 2. Exhaust air ducts not subject to condensation. up, and defrost conditions. These controls shall anticipate need for heat and use 3. Exposed ductwork within a zone that serves that zone. compression heating as the first stage of heat. Controls shall indicate when 1415 Piping Systems supplemental heating is being used through visual means (e.g., LED indicators). 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -8. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment Exception: Piping installed within unitary HVAC equipment. with a capacity over 225,000 Btu /h shall have modulating or staged combustion Water pipes outside the conditioned space shall be insulated in accordance with control. 000 Washington State Plumbing Code (WAC 51 -26) EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1416 Completion Requirements (Refer to NREC Section 1416 and the Building 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have Commissioning Guidelines, published by the Building Commissioning Association, a means for balancing, including but not limited to, dampers, temperature and for complete text and guidelines for building completion and commissioning pressure test connections and balancing valves. requirements.) JOFFRE SECHIER 6802 S 220 ST KENT WA 98032 RE: Permit No. M09 -145 151 ANDOVER PK E TUKW Dear Permit Holder: -or- Sincerely, o 0 Bill Rambo Permit Technician File: Permit File No. M09 -145 City of Tukwila Based on the above, you are hereby advised to: The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. Thank you for your cooperation in this matter. Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 05/24/2010. 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. In the event you do not call for an inspection and /or receive an extension prior to 05/24/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M09 -145 DATE: 11 -12 -09 PROJECT NAME: US BANK SITE ADDRESS: 151 ANDOVER PK E X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: PY(/ it'a ul ding Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Perniit-CenterUse,Only ; ;;� : INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ c : •s' t' ' 1F +' `•:i�: - mo .'s..° ^'.. �. LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route xi REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing sl ip.doc 2 -28 -02 • PERMIT MORD COPY el PLAN REVIEW/ROUTING SLIP Fire Prevention Structural Incomplete Structural Review Required n Approved with Conditions A A44 Vrj)i DATE: DATE: Planning Division ❑ Permit Coordinator Not Applicable No further Review Required n DUE DATE: 11-17-09 DUE DATE: 12-15-09 Not Approved (attach comments) n Permit-Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FIVESM *010JT FIVE STAR MECHANICAL CONSTRUCTION CONTRACTOR GENERAL UNUSE 4/30/19994/30/2010 ACTIVE COMFOP *064D2 COMFORT PLUS CONSTRUCTION CONTRACTOR AIR CONDITIONING AIR HEAT,VENTILATION,EVAPORAT 3/22/1994 3/21/2000 ARCHIVED FIVESSE941 KU FIVE STAR ENERGY SOLUTIONS CONSTRUCTION CONTRACTOR GENERAL UNUSE 5/24/2006 5/24/2008 EXPIRED Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 COLONIAL SURETY OF MD LPM4041162 06/01/2002 Cancelled $6,000.00 05/15/2002 1 COLONIAL AM CAS Et SURETY OF MD LPM4041162 06/01/1999 06/01/2002 $4,000.00 Name Role Effective Date Expiration Date JACKSON, SHIRLEY A 01/01/1980 JACKSON, HERB J 01/01/1980 Untitled Page General /Specialty Contractor A business registered as a construction contractor with MI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company COMFORT MECHANICAL INC 4252519840 6802 SO. 220TH STREET KENT WA 98032 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601954041 ACTIVE COMFOMI015LA CONSTRUCTION CONTRACTOR 6/1/1999 6/1/2010 HTG /VENT /AIR CONDITIONING UNUSED ther Associated Licenses Business Owner Information Bond Information Insurance Information r • 0 Page 1 of 2 https://fortress.wa.gov/lni/bbip/Detail.aspx 11/25/2009 # Brand Model Ton Total CFM OSA CFM Econo. SP Cap. Cool EER Btuh -In Btuh -Out AFUE Weight 1 Trane YFD241 20 8,000 1600 0 -100% 0.5 265,550 11 400,000 324,000 81 3228# # Brand Model CHP11 -2753 Ton 20 Total CFM 8,000 OSA CFM 1600 Econo. 0 -100% SP 0.5 Cap. Cool 240,000 EER 8.3 Btuh -In Btuh -Out AFUE Weight 3375# 1 Lennox La King County Assessor information for parcel number 0223100038 Taxpayer name Mailing address Addresses) at this parcel 151 ANDOVER PARK E 98188 Legal description ANDOVER INDUSTRIAL PARK # 2 LESS W 402.01 FT LESS N 235 FT ASSESSOR DATA Wa mNtlRhkwiva•a onlh4. m Ptlmpl4a byKI - coun t' at•Il }vaarr�Qlloumf•'and l •ut4E4 to aom•wttno�nac Catr'dy q a:A { n4 gde 11 rilonl arwwnnll•r, qmn of ImW.d fl I aocGn eK.04dP I POU'tlm•Anu• lh4 ue. olflir 7Df•QOaatxrd3r,PI4Yl ua Maduot. S a ti nly�h•arot b rr4 N for y m aie4 Wad•4 , 4ier7mW o400nr•4unNd' dvh•plr lndudjh0 quo AOt to i m•nw Wt ri..s a a4Nlatt qq,��}W � QPn ed.h p µ, b, or dono rrw h aUbt t, 111,11,141.0,41;6 Ce a "' a "raazoo ttc:* 1 ai e ' t xs F 41 � , £ 1)Y..‘ Y ... '' u �i!p c!acou . ki ?. frois hfotmrt 1PMr?.q.7 r)GI q" i3 c Y. `Y3 SITE PLAN Map of 151 Andover Park E Tukwila, WA by MapQuest MAVQUE5t • Q 2009�Map�iiest.lrio„__:_ u ' _ S154thSt _3 r 1 -- 6 - 3rd,�S l fi l` VICINITY MAP U S BANK CORPORATE PROPS 2800 E LAKE ST LAKE0012 MINNEAPOLIS MN 55406 Stmt;.' Parcel number Tax Account number Levy code Jurisdiction Present use Appraised value Page 2 of 2 11 I M Map Data 83 2009 N VTE or Tetaktas 0223100038 022310003805 2390 TUKWILA Bank $920,200 HVAC Equipment schedule (New) HVAC Equipment Schedule (Existing) EQUIPMENT SCHEDULE PROJECT DESCRIPTION: 1. REPLACE (1) EXISTING 20 -TON ROOFTOP HEAT PUMP UNIT WITH NEW 20 -'TON ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT WITH ECONOMIZER. 2. EXISTING AIR DISTRIBUTION BEING REUSED "NO WORK ". 3. PROVIDE AND INSTALL NEW 7 -DAY PROGRAMMABLE THERMOSTAT. GENERAL NOTES: 1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING. 2. THERMOSTAT TO PROVIDE MINIMUM 5 DEADBAND. 3. INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 4. ROUTE CONDENSATE TO SPLASH BLOCK. 5. PROVIDE COMMISIONING REPORT WITH OPERATIONS AND MAINTENANCE MANUALS. 6. VERIFY ALL DUCT DIMENSIONS PRIOR TO INSTALLATION. 7. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. ROOF ACCESS 0 ROOF PLAN (NTS) 1.5" GAS LINE TO METER ■ 110' TO METER By Date: SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical . iectricar . MPlumbing Gas Piping City of Tukwila 13UILDING DIVISION MAY a_5 Z010 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No KO+ l'15 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the viotatio of any adopted code or ordinance, Receipt of approve iel Copy and conditions is acknowledged: .4 pitiolitifai • City Of TWkwiia BUILDING DIVISION REVIEWED FOR CODE COMPLIA!CE TICAYED NOV 2 4 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 12 2009 PERMIT CENTER REVISIONS J 0 < „ w o � git. *) 0 ce ( ± ) tf5,a L., ',I W 0 -J 8 0 7, LT.J < rn < or, <('' co < r D 11 DATE: SCALE DRAWN: CHECKED: 1 Model Number ,- CHP11.2763 CHP11 -2763 • *AM Standard 340 Ratings Cooling Ratings Cooling Capacity (Btuh) Compressors (2) 240,000 Total unit watts 39.5/39.5 (79.0) 28,800 EER (Btuh /Watts) 229/229 (4593) 8.30 Integrated Part Load Value Outdoor Coil Fan Motors (2) 8.3 High Temperature Heating Ratings Total capacity (Btuh) 6.6 240,000 Total unit watts 28 24,700 C.O.P. Horsepower 2,8 Low Temperature Heating Ratings Total capacity (Btuhl 7 -1/2 134,000 Total unit watts Full load amps 18,700 C.O.P. 15.2 2.1 - - Refrigerant (22) charge Stage 1 Locked rotor amps 34 lbs. 0 oz. Stage 2 90.0 31 lbs. 0 oz. Indoor Coil Blower and Drive Selection Blower wheel nominal diameter x width lin.) Optional Exhaust Fan Motors 15 x 16 Factory Installed tDriver Nominal motor horsepower (3) - 1/4 5 Maximum usable horsepower 4 2 5.76 Voltage & Phase 9.8 200/230/460v -3ph RPM range Recom. max. fuse size (amps) 790 - 965 (tt600 - 760) Optional Factory Installed tDrives Nominal motor horsepower 150 7.1/2 Maximum usable horsepower 70 8.83 Voltage & Phase 150 200/230/460v-3ph RPM range: .. 70 900 - 1070 Indoor Coil • Net face area (sq. ft.) . . :: 23.5 Tube diameter (in.) & No. of rows .87 1/2 - 4 Fins per Inch • 15 Outdoor Coil Net fete area (sq. ft.) .87 38.9 Tube diameter (in.) & No. of rows 'Minimum Circuit Ampeclty 1/2 - 4 Fins per inch 127.0 15 Outdoor Coil Fans Dlametet (in.) & No. of blades 63.0 (2) 28 - 5 Air volurne (cfm) 132.0 (2) 6800 Motor horsepower 62.0 (2) 1 Motor watts 460 (2) 1000 Condensate drain size mpt•lin.1 126.0 (2) 1 -1/4 No. & size of filters (ln.) (11) 16 x 20 x 1 Net weight of basic unit (lbs.) (1 Package) 153,600 2900 Optional Electric Heat Model No. ECH11 -275 kw input range . 142,300 277.0 30.45.60 -75-90 Optional Roof Mounting Frame - (Net weight) Standard 157,000 RMF11.275 (315 lbs.) Horizontal 220 RMFH11 -275 (440 lbs.) Optional Economizer & Controls - (Net weight) REMD11M -275 (290 lbs.) Optional Gravity Exhaust Dampers - (Net weight) GED11 -275 (30 lbs.) Optional Power Exhaust Dampers Model No, - (Net weight) 297,0 PED11 -275 (160 lbs.) Exhaust Fentf: • Diameter lin.) & No. of blades 240 (3) 18 - 5 Total air volume (cfm) 7050 Motor horsepower (3) 1/4 Watts input (total) 172,000 1100 Optional'?r;ling Supply and Return Air Diffusers (Net weight) Step•down 2 RTD11.275 (403 1bs.) Flush 188,100 Fi11•275 (383 lbs.) Transition SRT11 -275 (80 lbs.) Optional Fresh Air Damps' & Filter Size (in.) - (Net weight) 80.0 OAD11-275 (115 lbs.) 1 - 28 x 31 x 1 Optional Automatic OAD11 Damper Kit - Net weight) 88G13 (16 lbs.) Electrical characteristics ' 200 200 to 460 volt - 60 hertz - 3 phase Model No. ,- CHP11.2763 Line voltage data - 60 Hz - 3 phase 200V 230V 460V Compressors (2) Rated load amps (total) 39.6/39.5 (79.0) 39.5/39.5 (79.0) 20.4/20.4 140.81 Locked rotor amps (total) 229/229 (4593) 229/229 (458.0) 116/116 (232.0) Outdoor Coil Fan Motors (2) Full Toad amps (total) 12.8 10.4 6.6 Locked rotor amps (total) 30 28 13.2 Indoor Coil Blower Motor Horsepower 5 7.1/2 5 7 -1/2 5 7 -1/2 Full load amps 17.6 25.3 15.2 22.0 7.8 11 Locked rotor amps 100.0 160.0 90.0 127.0 45.0 64.0 Optional Exhaust Fan Motors (No.) Horsepower 13) - 1/4 (3) - 1/4 (3) - 1/4 Full load amps (total) 4 2 4 2 22 Locked rotor amps (total) 9.8 9 8 4.9 Recom. max. fuse size (amps) Less Exhaust Fans 150 150 150 160. 70 70 With Exhaust Fans 150 150 150 • 160 70 70 Unit Power Factor Lees Exhaust Fans . :: .87 .:•: .87 . :: .87 With Exhaust Fans .68 .87 -88 .87 .88 .87 'Minimum Circuit Ampeclty Less Exhaust Fans 120.0 127.0 115.0 122,0 60,0 63.0 With Exhaust Fans 124.0 132.0 119.0 126.0 62.0 65.0 Electric Heat Model No. & Net Weight - No. of Steps Volts Input kw Input Btuh Output . Total Electric ° Minimum AmEacity Unit & Heat Circuit 5 hp 7.1/2 hp Manual Outside air Damper 200 20.8 71,000 2010 209.0 210 23.0 78,500 2 220 25.2 : ,000 Unit Mounted Circuit Breaker tECH11 -275 -30 Unit Mounted Disconnect 230 27.5 93,900 209.0 215.0 (135 lbs.) . 240 30.0 102,400 LPG Conversion Kit 440 25.2 86,000 Adapter Curb 850.0 Ib 1 460 27.5 93,900 105.0 108.0 OA ® 480 30.0 102,400 F 2880.0 Ib 2203.0 lb 701.0 Ib 200 31.3 106,800 238.0 248.0 210 34.5 117,700 3 220 37.8 129,000 tECH11- 275.45 230 41.3 141,000 252.0 259.0 (145 lbs.) 240 45.0 153,800 440 37.8 129,000 2 460 41.3 141,000 126.0 130.0 480 45.0 153,600 200 41.7 142,300 277.0 285.0 210 46.0 157,000 4 220 50.4 172,000 tECH11-275-65 230 55.1 188,100 297,0 304.0 (145 lbs.) 240 60.0 204,800 440 50.4 172,000 . 2 460 55.1 188,100 148.0 151.0 480 80.0 204,800 200 52.1 177,700 318.0 326.0 210 67.4 196,000 5 220 63.0 215,000 tECH11- 275-76 230 68.9 235,000 342.0 349.0 1155 lbs.) 240 75.0 255,900 440 63.0 215,000 3 460 68.9 235,000 169,0 173.0 480. 75.0 255,900 tECH11 -275 -90 6 200 62.5 213,300 357.0 385.0 (155 lbs.) 210 68.9 235,000 Accessory Accessory Economizer 80.01b Motorized Outside Air Damper Manual Outside air Damper Oversized Motor High Efficiency Motor High Static Drive Thru the Base Electrical l Unit Mounted Circuit Breaker Unit Mounted Disconnect I Power Exhaust / 95.0 Ib Hinged Doors Zone Sensor LPG Conversion Kit Powered Convenience Outlet Adapter Curb 850.0 Ib BASE UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITY SHIPPING NET OA ® © DO E F 2880.0 Ib 2203.0 lb 701.0 Ib 575.01b 421.01b 504.0 lb 57" 35" Voyager YCD Items: YCD_-1 (This item is not 'In Job') 7/13/2009 8:21:20 AM CORNER WEIGHT BASE UNIT: ECONOMIZER: POWER EXHAUST: ADAPTER CURB: TOTAL W /ACC: Comfort Mechanical - WFB Tukwila RIGGING AND CENTER OF GRAVITY WEIGHT DATA (NEW UNiT #2203 #80 #95 #850 #3328 INSTALLED OPTIONS NET WEIGHT DATA TRAM" NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT OF OPTION /ACCESSORIES ADD 5 LBS TO NET WEIGHT. 3, WET WEIGHT OF OPTIONAL ACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN ORDERING FACTORY INSTALLED ACCESSORIES. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE < 5 LBS. 5. WEIGHT ARE OF BASE UNIT ONLY. FOR TOTAL WEIGHT, 10 DIGIT FACTORY INSTALLED OPTION (ECONOMIZER AND /OR OVERSIZED MOTOR OR FIOP /ACCESSORY WEIGHT MUST BE ADDED. TOPSS Dimension Drawing ALLW ELHTS AND D;tiENSDNS ARE APPROXIMATE. CERTFED PRNTS ARE AVA1ABLE UPON REQUEST. Page: 4 4-) SPECIFICATIONS 'Rated In accordance with ARI Standard 340. Cooling Ratings - 96°F'tiutdoor air temperature and 60 °F db /67 °F Wiz entering Indoor coil sir, minimum external duct static pressure. High Temperature Heating Ratings - 47°F db /43°F wb outdoor air temperature and 70 °F db entering Indoor call alt. Low Temperature Heating Ratings - 17 °F db /16°F wb outdoor air temperature and 70 °F db entering Indoor coil air. tUeing total alr volume and system static premure requirementsa determine from blower performance tables rpm end motor output required. ttMator pulley furnished with unit for field Installation, if moulted. WEIGHT DATA (EXISTING UNIT): BASE UNIT: #2900 ELECTRIC HEAT: #155 ECONOMIZER: #290 EXHAUST DAMPER: #30 TOTAL W /ACC: #3375 -31f- ELECTRICAL DATA *Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. NOTE - Extremes of operating range are plus and minus 10% of line voltage. OPTIONAL ELECTRIC HEAT DATA • Refer to National Electrical Code manual to determine wire, fuse end disconnect size requirements. Use wires suitable for et least 167 °F. . . 1 May be used with two stage o contrl - 31g - CW MAY 2:5:2010 1 REVIEWED FOR CODE COMPLIANCE AP ROVED NOV 2 4 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 12 2009 PERMIT CENTER REVISIONS DATE: SCALE: 'DRAWN CHECKED: Ig 0