HomeMy WebLinkAboutPermit M09-149 - WESTFIELD SOUTHCENTER MALL - MOTHERHOOD MATERNITYMOTHERHOOD MATERNITY
1057 S0UTHCENTEg2 MALL
M09 -149
Parcel No.: 6364200010
Address:
Suite No:
City Ilk Tukwila
1057 SOUTHCENTER MALL TUKW
Tenant:
Name: MOTHERHOOD MATERNITY
Address: 1057 SOUTHCENTER MALL , TUKWILA WA
Owner:
Name: WEA SOUTHCENTER LLC BSIP
Address: TOTAL 13 PARCEL NUMBERS , 2010 NEW PLAT MAJOR 920247
Contact Person:
Name: LYN DAVIES
Address: 75 60TH ST SW , WYOMING MI
Contractor:
Name: MERIT MECHANICAL INC.
Address: PO BOX 2109 , REDMOND, WA
Contractor License No: MERITMI163CM
DESCRIPTION OF WORK:
NEW OR REPLAVEMENT OF DUCT WORK AND FANS FOR TENANT IMPROVEMENT IN EXISTING
MALL SPACE
Value of Mechanical: $1,850.00
Type of Fire Protection:
Furnace: <100K BTU 0
>100K BTU 0
Floor Furnace 0
Suspended/Wall/Floor Mounted Heater 0
Appliance Vent 0
Repair or Addition to Heat /Refrig /Cooling System.... 0
Air Handling Unit <10,000 CFM 0
>10,000 CFM 0
Evaporator Cooler 0
Ventilation Fan connected to single duct 1
Ventilation System 0
Hood and Duct 0
Incinerator: Domestic 0
Commercial/Industrial 0
doc: IMC -10/06
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 -431 -2451
Web site: http: / /wwwci.tukwila.wa.us
MECHANICAL PERMIT
EQUIPMENT TYPE AND OUANTITY
* * continued on next page **
M09 -149
Permit Number: M09 -149
Issue Date: 02/01/2010
Permit Expires On: 07/31/2010
Phone:
Phone: 800 - 285 -7866 X1
Phone: 425 883 -9224
Expiration Date: 06/01/2011
Fees Collected: $196.29
International Mechanical Code Edition: 2006
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 8
Thermostat 1
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment
Printed: 02 -01 -2010
Permit Center Authorized Signature:
doc: IMC -10/06
Print Name: 1( *r ✓s
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite # 100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performancetQf work. I am authorized to sign and obtain this mechanical permit.
040)
Permit Number: M09 -149
Issue Date: 02/01/2010
Permit Expires On: 07/31/2010
Date: k 1 0
Date: 2 I 1 1100
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
M09 -149 Printed: 02 -01 -2010
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
1057 SOUTHCENTER MALL TUKW
MOTHERHOOD MATERNITY
PERMIT CONDITIONS
•
Permit Number:
Status:
Applied Date:
Issue Date:
M09 -149
ISSUED
11/18/2009
02/01/2010
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
12: ** *FIRE DEPARTMENT CONDITIONS * **
13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned
in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051)
15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
doc: Cond -10/06
M09 -149 Printed: 02 -01 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
0
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051)
17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051)
18: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051)
19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Cond -10/06
* *continued on next page **
M09 -149 Printed: 02 -01 -2010
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature:
Print Name: 0411 114j,
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
doc: Cond -10/06 M09 -149
Date: 1 - , ' / /t1/0
ordinances governing
or local laws regulating
Printed: 02 -01 -2010
Company Name:
CITY OF TUKWILP
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: / /,rwii'.ci.hrinniln.ii a. us
- 1"i3
Company Name: 00,
r "
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 1057 5��, �f �u ��, /
Tenant Name: /tie 2*?v,:/n 44 u-I
Property Owners Name: til -/ k..1// J /
Mailing Address: //tO/ �� "� L/ �,u "P �� ✓� l
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: A. Y / j9a t) / « `) it.. Day / ` y Telep � , � J ,7 1 ';�.� k
Mailing
... Address: 'I <y - /1 �.
y .- C . / l 'J n nil 1 /( 1 / 7 �1 � t
City
State Zip
E -Mail Address /7 / (Q.& Fax Number: &/b., C 7 / q q ?‘.5/
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
h ��
Mailing Address:
Zip
Contact Person:
E -Mail Address:
Contractor Registration Number:
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: C t pi-La. 4 Al 6 r, , n /} rc Lr `fe ct
Mailing Address: 1/1 1 f r'^ h I c) g
Contact Person: C t5 r /v/ p � c
E -Mail Address:
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
S4.4lt,..1
Mailing Address: 635 we s i Va -i PKw' *34c
Contact Person: 0 "
E -Mail Address:
H:\Applications \Fomu- applications On tine\2009 Applimtions\1-2009 - Permit Applicatioadoc
Revised: 1 -2009
bh
Building Permit No. .00g
Mechanical Permit No. MO q q
Plumbing /Gas Permit No. G 13,
Public Works Permit No.
Project No.
(For office use only)
King Co Assessor's Tax No.: ✓.7 3 3t' ZU — 00 in
Suite Number: / 3o5 Floor:
New Tenant: Yes ❑ ..No
// �
7114, p�rS
c igc f
� .
City
Day Telephone:
Fax Number:
Expiration Date:
Ci
State
state
Day Telephone: gi?) (s -
Fax Number: So) G3s
Zip
7 6 v/Z
Zip
City State Zip
Day Telephone: g /7) Y to n
Fax Number: SSl7) - `3Y
Page 1 of 6
BUILDING PERMIT INFORMTION — 206 - 431 -3670
Valuation of Project (contractor's bid price): $ !3 000 Existing Building Valuation: $
1
Scope of Work (please provide detailed information): 4:—/ 1/
.e.L ll it . / i/� 04- ,-, ,�.-l - 1 1 "X I 4i- re 5�.f1e-P. 7GY 0 �---. ' - iu-/ /��uau✓�R
G"J,✓ /e.... - 4 i c 4.46 J /
Will there be new rack storage? ❑ Yes
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact:
*No If yes, a separate permit and plan submittal will be required.
Will there be a change in use? ❑ Yes ❑ No If `yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers 4 Automatic Fire Alarm ❑ None
Handicap:
Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes
If "yes ; attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety
No
to Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
W Appli®Lons\Forms- Applications On L&no 2009 Appbmtions \1 -2009 - Pamit Applteaboadoc
Revised: 1 -2009
bb
Page2of6
xistingj
. -- "
Inferior Remoc l
Addition to
Existing
Structure
New
Pe
Co struction r. - r
�= _
Type of
Occupancy Qer
t.... .IBC `'
1' Floor
1 jo 5
--
ls�
11 - i
Aft
r Floor
3` Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
BUILDING PERMIT INFORMTION — 206 - 431 -3670
Valuation of Project (contractor's bid price): $ !3 000 Existing Building Valuation: $
1
Scope of Work (please provide detailed information): 4:—/ 1/
.e.L ll it . / i/� 04- ,-, ,�.-l - 1 1 "X I 4i- re 5�.f1e-P. 7GY 0 �---. ' - iu-/ /��uau✓�R
G"J,✓ /e.... - 4 i c 4.46 J /
Will there be new rack storage? ❑ Yes
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact:
*No If yes, a separate permit and plan submittal will be required.
Will there be a change in use? ❑ Yes ❑ No If `yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers 4 Automatic Fire Alarm ❑ None
Handicap:
Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes
If "yes ; attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety
No
to Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
W Appli®Lons\Forms- Applications On L&no 2009 Appbmtions \1 -2009 - Pamit Applteaboadoc
Revised: 1 -2009
bb
Page2of6
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Fumace<100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
Diffuser
Q
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
1
Thermostat
'
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
Incinerator - Domestic
Other Mechanical
Equipment
Air Handling Unit
<10,000 CFM
Incinerator — Comm/Ind
Scope of Work (please provide detailed information):
Use. Residential: New .... ❑ Replacement .... ❑
Commercial: New Replacement ....
Fuel Type: Electric
H:Wppli®tions\Fomms- Applications On Iine\2009 ApphmtionA1 -2009 - Pe+mn Applscationdoc
Revised: 1 -2009
bb
• O
MECHANICAL PERMIT INFORMATION — 206 - 431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name: 1 7
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Mechanical work (contractor's bid price): $ i s r'J D
A a- k! e irP�l !ia r�.(.t ,.a r , cs r -A- - 1� 7I,-t 4) ,t e C4AAA a
tA. S
i // {
Gas....❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Page 4 of 6
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
'
Shower, single head trap
Lavatory
I
Wash fountain
Receptor, indirect waste
Sinks
1
Urinals
Water Closet
I
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets/outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric-type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
FL Applications\FomwAppheations On-Line \2009 Applications \1 -2009 Permit Apphcation.doc
Revised: 1 -2009
bh
PLUMBING AND GAS PIPIN ERMIT INFORMATION - 206 - 431 -3670
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: ►D
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $ /0 000
Scope of Work (please provide detailed information):
I iti 1,t(u- fig,,,, oc fes rrxu.� y u
Building Use (per Intl Building Code): a — i
Occupancy (per Intl Building Code): t / " (Wte t c b u:u,.: - i 1 e
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
State
Zip
Page 5 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER 7
q� Signature: / n
Print Name: ( 4/4 i)14 / e_
Mailing Address: 7- b 0 1 n i / .9 0
Date Application Expires:
Date Application Accepted:
tHq- cc
H:\Applications\Foms- Applications On Line\2009 Applications \1 -2009 - Pemtt Applicanon.doc
Revised: 1 -2009
bb
City
Date: ////./or
Day Telephone Z ` 2R6-6)(/'
6-
Da Tele hone• 2R
� r ,-� n )(
(0) 1 0 AI a 6 .,41
State
Staff Initials:
Page 6 of 6
1
Receipt No.: R10 -00167
Initials: WER
User ID: 1655
Payee: MERIT MECHANICAL
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 24138 157.03
Authorization No.
ACCOUNT ITEM LIST:
Description
MECHANICAL - NONRES
RECEIPT
•
Parcel No.: 6364200010 Permit Number: M09 -149
Address: 1057 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 11/18/2009
Applicant: MOTHERHOOD MATERNITY Issue Date:
Payment Amount: $157.03
Account Code Current Pmts
000.322.102.00.00 157.03
Total: $157.03
Payment Date: 02/01/2010 01:56 PM
Balance: $0.00
a3J833bi
3WAHd
doc: Receiot -06 Printed: 02 -01 -2010
Receipt No.: R09 -01839
Payee: PRECISION PERMIT SERVICE
ACCOUNT ITEM LIST:
Description
PLAN CHECK - NONRES
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 6990 39.26
Authorization No.
RECEIPT
Parcel No.: 6364200010 Permit Number: M09 -149
Address: 1057 SOUTHCENTER MALL TUKW Status: PENDING
Suite No: Applied Date: 11/18/2009
Applicant: MOTHERHOOD MATERNITY Issue Date:
Initials: WER Payment Date: 11/18/2009 09:52 AM
User ID: 1655 Balance: $157.03
Account Code Current Pmts
000.345.830 39.26
Total: $39.26
Payment Amount: $39.26
PAYMENT
RECEIVED
doc: Receiot -06 Printed: 11 -18 -2009
Project: , r A
A /I " /IJ �J�c- 1.40b( r.
Type of InspectioPi)1,� -/
/
/ cal ed:
Address
4Y 7 / N
Special Instructions:
Date Wanted:
?� fZ / �
am
Requester:
Phone No
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
'f
PERMIT NO.
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
(A per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
rl $60.00 ' CTION F E REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
Proj ct: ' r
D ihPr A a/ I,9,zGI //
Type of Inspection:
/
/
Address:
/057 ,'14 //
Date Called:
/'
Special Instructions:
0 3,933 5 - 0 /
_
Date Wanted:
/3/a
/
,gym.
p.m.
Requester:
Phone No:
//23- iNz - i
//m5
INSPECTION RECORD
Retain a copy with permit
IN CTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
❑ Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
.6 /en)kih- /
�l
(/ S eedxe4 /0)1 i GCTCe - 'a( i
(2) 1.4- / A/le
D
.00 REINSPECTION FEE � EQUIRE rior to inspection, fee must be
id at 6300 Southcenter Blvd., Su , t 10,0. Call to schedule reinspection.
Date:
.r-
1,
Cooling Equipment Schedule
Equip.
ID
Brand Name'
Model No.
Capacity
Btu /h
Total CFM
OSA CFM
or Econo?
SEER
or EER
IPLV
Location
d/hl- i
T s
-1,:�
3& OW
12-00
N w
Applicant Address: G 3 5 !) , // �n J/c
li(/ I °"'''
i.
C
T �lot�f
Applicant Phone: 817_ 1/40 - as5r
RECEIVFr
NsV 2 4 2009
M 0 9
IN. i
NOV 18 2009
Cii: of Tu rwiin
PERMIT CENTE
Heating Equipment Schedule
Equip. _
�: •i. IIlL"t��YYyra ii
Model No.
Capacity
Btu /h
Total CFM
OSA cfm
or Econo?
Input Btuh
Output Btuh
Efficiency"
COD I. COMPLIANCE
Location of Service
/
Applicant Name: To k Pte- "`t 6,,t-si-i
Applicant Address: G 3 5 !) , // �n J/c
li(/ I °"'''
i.
C
T �lot�f
Applicant Phone: 817_ 1/40 - as5r
RECEIVFr
NsV 2 4 2009
M 0 9
IN. i
NOV 18 2009
Cii: of Tu rwiin
PERMIT CENTE
Project Info
Project Address l �! f , A6 / few/
Equip.
ID
Brand Name'
Model No.
CFM
sP
HP /BHP
Flow Control
Location of Service
/
Applicant Name: To k Pte- "`t 6,,t-si-i
Applicant Address: G 3 5 !) , // �n J/c
li(/ I °"'''
i.
C
T �lot�f
Applicant Phone: 817_ 1/40 - as5r
RECEIVFr
M 0 9
IN. i
NOV 18 2009
PERMIT CENTE
Project Info
Project Address l �! f , A6 / few/
Date
!//1649
For Building Dept. Use
7 f� I �u GL /
� b
k -idIA kid
/
Applicant Name: To k Pte- "`t 6,,t-si-i
Applicant Address: G 3 5 !) , // �n J/c
li(/ I °"'''
i.
C
T �lot�f
Applicant Phone: 817_ 1/40 - as5r
'
CITY OF TUKWILA - BUILDING DIVISION
2006 Washington State Nonresidential Energy Code Compliance Form
Mechanical Summary
MECH -SUM
2006 Washington State Nonresidential Energy Code Compliance Forms
Project Description
Briefly describe mechanical
system type and features.
IBdes Plans
FILE COPY
N6241 TEA/AztJ7 4 Dr-
Include documentation requiring compliance with commissioning requirements, Section 1416.
Revised July 2007
Compliance Option
0 Simple System 0 Complex System 0 Systems Analysis
(See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.)
Equipment Schedules
The following information is required to be incorporated with the mechanical equipment schedules on the
plans. For projects without plans, fill in the required information below.
Mechanical Permit Plans Checklist I !MECH -CH
2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007
i i Address
„ Li ii
Date Q-J9
The following information is necessary to check a rf echanical permit application for compliance with the mechanical requirements in the
Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
HVAC REQUIREMENTS (Sections 1401 -1424)
1411
Equipment performance
1411.4
Pkg. elec. htg.& clg.
List heat pumps on schedule
1411.1
Minimum efficiency
Equipment schedule with type, capacity, efficiency
1411.1
Combustion htg.
Indicate intermittent ignition, flue /draft damper & jacket loss
1412
HVAC controls
Y es
1412.1
Temperature zones
Indicate locations on plans
14/16°/. 0
1412.2
Deadband control
Indicate 5 degree deadband minimum
1412.3
Humidity control
Indicate humidistat
1412.4
Automatic setback
Indicate thermostat with night setback and 7 diff. day types
Y �7
1412.4.1
Dampers
Indicate damper location and auto. controls & max. leakage
m 0
�GS
1412.4.2
Optimum Start
Indicate optimum start controls
0
1412.5
Heat pump control
Indicate microprocessor on thermostat schedule
1412.6
Combustion htg.
Indicate modulating or staged control
1412.7
Balancing
Indicate balancing features on plans
1412.8
Ventilation Control
Indicate demand control ventilation for high- occupancy areas
At e , 0
1422
Thermostat interlock
Indicate thermostat interlock on plans
1423
Economizers
Equipment schedule
1413
Air economizers
1413.1
Air Econo Operation
Indicate 100% capability on schedule
1413.1
Wtr Econo Operation
Indicate 100% capacity at 45 degF db & 40 deg F wb
1413.2
Water Econo Doc
Indicate clg load & water econoe & clg tower performance
1413.3
Integrated operation
Indicate capability for partial cooling
1413.4
Humidification Indicate direct evap or fog atomization w/ air economizer
1414
Ducting systems
"�,�
1414.1
Duct sealing
Indicate sealing necessary
p/
y -es
1414.2
Duct insulation
Indicate R -value of insulation on duc
f
1415.1
Piping insulation
Indicate R -value of insulation on piping
1416
Completion Requirements
1416.2.1
Commissioning
Provide commissioning plan
I GS
1416.2.2 -3
Sys.Bal & Func.Test
Indicate air and water system balancing & functional testing
,
1416.2.4
Commissioning
Indicate O &M manuals, record drawings, staff training
1416.2.5
Comm. Report
Indicate requirements for prelim. & final commissioning report
1434
Separate air sys.
Indicate separate systems on plans
Mechanical
Summary Form
Completed and attached. Equipment schedule with types,
input/output, efficiency, cfm, hp, economizer
SERVICE WATER HEA1 ING AND HA1 ED POOLS (Sections 1440 - 1454)
1440
Service water htg.
Y es
1441
Elec. water heater
Indicate R -10 insulation under tank
, '
1442
Shut -off controls
Indicate automatic shut -off
1443
Pipe Insulation
Indicate R -value of insulation on piping
1452
Heat Pump COP
Indicate minimum COP of 4.0
1452
Heater Efficiency
Indicate pool heater efficiency
1453
Pool heater controls
Indicate switch and 65 degree control
2006 Washin• ton State Nonresidential Ener
Code Com • liance Form
2. Combustion air intakes. 2006 Washington State Nonreside
3. Gravity (nonmotorized) dampers are acceptable in buildings less
than 3 stories in height.
4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief
outlets in the first story and levels below the first story of buildings
three or more stories in height.
1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply
air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum
start controls shall be designed to automatically adjust the start time of an HVAC
system each day to bring the space to desired occupied temperature levels
immediately before scheduled occupancy. The control algorithm shall, as a
minimum, be a function of the difference between space temperature and occupied
setpoint and the amount of time prior to scheduled occupancy.
1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include
microprocessor controls that minimize supplemental heat usage during start-up, set-
up, and defrost conditions. These controls shall anticipate need for heat and use
compression heating as the first stage of heat. Controls shall indicate when
supplemental heating is being used through visual means (e.g., LED indicators).
1412.6 Combustion Heating Equipment Controls: Combustion heating equipment
with a capacity over 225,000 Btu /h shall have modulating or staged combustion
control. 000
EXCEPTIONS: 1. Boilers. 2. Radiant heaters.
1412.7 Balancing: Each air supply outlet or air or water terminal device shall have
a means for balancing, including but not limited to, dampers, temperature and
pressure test connections and balancing valves.
nttl EUt AMIS/ aOMPilirAt cif6iGftaices to a minimu m of R -11 and any
exterior envelope surfaces per Chapter 13. Outside air ducts serving individual
supply air units with less than 2,800 cfm of total supply air capacity shall be insulated
to a minimum of R -7 and are not considered building envelope. Other outside air
duct runs are considered building envelope until they,
1. connect to the heating or cooling equipment, or
2. are isolated from the exterior with an automatic shut -off damper complying
with Section 1412.4.1.
Once outside air ducts meet the above listed requirements, any runs within
conditioned space shall comply with Table 14 -5 requirements.
Other ducts and plenums shall be thermally insulated per Table 14 -5.
Exceptions:
1. Within the HVAC equipment.
2. Exhaust air ducts not subject to condensation.
3. Exposed ductwork within a zone that serves that zone.
1415 Piping Systems
1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6.
Exception: Piping installed within unitary HVAC equipment.
Water pipes outside the conditioned space shall be insulated in accordance with
Washington State Plumbing Code (WAC 51 -26)
1416 Completion Requirements (Refer to NREC Section 1416 and the Building
Commissioning Guidelines, published by the Building Commissioning Association,
for complete text and guidelines for building completion and commissioning
requirements.)
o PE Pi COPY •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M09 -149 DATE: 11 -18 -09
PROJECT NAME: MOTHERHOOD MATERNITY
SITE ADDRESS: 1057 SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Buliding Division
Public Works
Complete Incomplete ❑
TUES/THURS RO TING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
Documents /routing slip.doc
2 -28 -02
C 11
Fire Prevention Planning Division
Structural
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -19-09
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
❑ No further Review Required
DATE:
n
n
APPROVALS OR CORRECTIONS: DUE DATE: 12 -17 -09
Approved n Approved with Conditions ❑ Not Approved (attach comments) ri
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
AUTOMMC044QH
AUTOMATED
MECH
CONTROLS
INC
CONSTRUCTION
CONTRACTOR
GENERAL
UNUSED
11/8/1996
6/1/2010
SUSPENDED
Name
Role
Effective Date
Expiration Date
KIRKWOOD, RODERICK V
PRESIDENT
02/14/1984
Bond
Amount
KIRKWOOD, JOAN M
SECRETARY
02/27/2006
08358695
FRICKBERG, WILLIAM MICHAEL
VICE PRESIDENT
02/27/2006
Bond
Bond
Company
Name
Bond Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
10
FIDELITY Et
DEPOSIT
CO OF MD
08358695
02/01/2010
Until
Cancelled
$12,000.00
01/20/2010
9
ARCH INS
CO
SU1041124
02/01 /200
Until
Cancelled
02/01/2010
$12,000.0001
/12/2009
8
TRAVELERS
CAS Et
SURETY CO
081S103546895BCM07/22/2001
Until
Cancelled
02/01/2009
$12,000.0003/07
/2002
7
TRAVELERS
CAS Et
SURETY CO
081S103546895BCMO2/01/2001
07/22/2001
$6,000.00
06/29/2001
6
UNITED
PACIFIC
2473230
02/01/1998
Until
02/01/2001
$6,000.00
Untitled Page
General /Specialty Contractor
A business registered as a construction contractor with LEtI to perform construction work
within the scope of its specialty. A General or Specialty construction Contractor must
maintain a surety bond or assignment of account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent
Company
MERIT MECHANICAL
INC
4258839224
PO BOX 2109
REDMOND
WA
980732109
KING
Corporation
UBI No.
Status
License No.
License Type
Effective Date
Expiration
Date
Suspend Date
Specialty 1
Specialty 2
600517946
ACTIVE
MERITMI163CM
CONSTRUCTION
CONTRACTOR
2/14/1984
6/1/2011
GENERAL
UNUSED
Other Associated Licenses
Business Owner Information
Bond Information
•
•
Page 1 of 2
https: // fortress .wa.gov /lni/bbip/Detail.aspx 02/01/2010
ADJACENT TENANT
MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
MALL COMMON AREA
MECHANICAL CODED NOTES
O TOILET EXHAUST FAN, PENN VEN77LA TOR #Z5H (OR EQUAL)
120V, 1; 75 CFM FURNISHED AND INSTALLED BY MECH.
CONTRACTOR, FINAL WIRING BY ELECTRICAL CONTRACTOR.
EXTEND 6 ' ' DUCT TO EXISTING (FIELD VERIFY) TOILET
EXHAUST DUCT OR ROOF CAP.
0 RELOCATE EXISTING THERMOSTAT FOR VAV -1 AS SHOWN. VERIFY IN FIELD.
EXISTING MANUAL DAMPER AT DIFFUSER. VERIFY IN FIELD.
0 EXISTING SMOKE DETECTOR IN AIR DUCT TO SHUT DOWN UNIT UPON
SENSING SMOKE VERIFY IN FIELD. PROVIDE NEW IF NOT EXISTING.
EXISTING DIFFUSER TO BE RELOCATED AS SHOWN. CLEAN AND ADJUST AS
REQUIRED TO ENSURE PROPER OPERA 770N AND PAINT F1X7URES TO
MATCH' CEILING(S). MECHANICAL' CONTRACTOR TO EXTEND BRANCH DUCT
TO NEW LOCA770N AS SHOWN. REBALANCE DIFFUSER AS SHOWN. FIELD
VERIFY EXACT LOCATION & REQUIREMENTS OF APPLICABLE)
EXISTING VAV UNIT TO REMAIN. G.C. SHALL INSPECT FOR DEFECTS
AND REPORT ANY PROBLEMS TO M. W.I. PROJECT MANAGER.
EXISTING RETURN GRILLE TO BE RELOCATED AS SHOWN. VERIFY IN FIELD.
T.G.C. SHALL REUSE EXISTING MAIN TRUNK LINE OF DUCTWORK
REMOVE EXISTING BRANCH DUCTS AND FLEX. PROVIDE NEW BRANCH
DUCTS TO RELOCATED DIFFUSERS PER SCHEDULE. CAP AND SEAL
ALL UNUSED DUCTWORK OR 'OPENINGS AIRTIGHT. BALANCE
ACCORDINGLY.
EXISTING 16"0 INLET FOR VAV
EXISTING OPENING ABOVE CEILING. FIELD VERIFY.
c
NOTES:
EXISTING SUPPLY AIR AND RETURN AIR MAIN
DUCTS TO REMAIN. FIELD VERIFY EXACT SIZE,
LOCATION AND ELEVA710N. CAP ALL UNUSED
BRANCH DUCTS AND REPLACE INSULATION
AS REQUIRED.
NOTES:
ALL EXISTING FIRE ALARM DEVICES TO REMAIN.
MODIFICA770NS TO ANY EXISTING DUCT MOUNTED
SMOKE DETECTOR(S) AND ASSOCIATED WIRING
FOR ALARM /SHUT -DOWN SYSTEM TO BE
PERFORMED BY LANDLORD APPROVED HVAC
CONTRACTOR AT TENANT'S EXPENSE.
NOT
EXISTING S.A. DIFFUSERS AND R.A. GRILLES ARE
TO BE REUSED. CLEAN AND ADJUST AS REQUIRED
TO ENSURE PROPER OPERA 770N AND PAINT
FIXTURES TO MATCH CEILING(S). EXISTING SUPPLY
AIR AND RETURN AIR MAIN DUCTS TO REMAIN.
FIELD VERIFY EXACT SIZE, LOCA770N AND
ELEVA 770N. CAP ALL UNUSED BRANCH DUCTS
AND REPLACE INSULA 170N AS REQUIRED.
MECHANICAL GENERAL NOTES
1. CONTRACTOR IS REQUIRED TO READ THE SPECIF1CA770NS
AND REVIEW THE DRAWINGS OF ALL DIVISIONS OF WORK
CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF THIS
WORK AND THE WORK OF ALL SUBCONTRACTORS Wl7H ALL
DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPON-
SIBILITY TO PROVIDE ALL THE SUBCONTRACTORS'WI7H A
COMPLETE SET OF BID DOCUMENTS
2 THE CONTRACTOR SHALL FURNISH AND INSTALL ANY
ADD71ONAL STRUCTURAL STEEL REQUIRED TO SUPPORT
ANY MECHANICAL EQUIPMENT THIS CONTRACTOR SHALL
COORDINATE LOCATIONS AND REQUIREMENTS WITH THE
GENERAL CONTRACTOR AND LANDLORD PRIOR TO BID.
3. THE CONTRACTOR SHALL ENSURE ALL EQUIPMENT, PIPING
AND DUCTWORK NOT BEING USED OR SHOWN TO REMAIN
IS FULLY REMOVED AND NOT ABANDONED. REFER TO
THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
4. MAXIMUM FLEXIBLE DUCT LENGTH TO BE 5' -0 ".
5. SEE SHEET MP1.1 FOR THE MECHANICAL SPECIFICATIONS,
SCHEDULES, DETAILS AND PLUMBING STACK AND RISER
DIAGRAMS.
VAV - NOTES
DESIGN IS BASED ON L.L. PROVIDING 55 DEGREE 365 DAYS PER YEAR.
T.G.C. SHALL MAINTAIN ALL LL. RETURN AIR OPENINGS (W /FIRE DAMPERS IF RIGID) IN
DEMISING WALLS TO ENSURE OPERA770N OF L.L.'S CENTRAL HVAC SYSTEM.
MECHANICAL NOTES
1. T.G.C. REPAIR, CLEAN, AND /OR REPLACE DIFFUSERS AS
REQUIRED. T.G.C. SHALL PAINT ALL DIFFUSERS AND GRILLES TO
MATCH ADJACENT CEILING OR AS SPECIFIED IN ARCHITECTURAL
DRAWINGS.
2. T.G.C. SHALL DEMOLISH AND REMOVE ANY EXISTING
DUCTWORK AND DIFFUSERS NOT BEING REUSED.
3. ALL EXISTING DUCTWORK, DIFFUSERS, VAV'S AND GRILLES TO
REMAIN AND BE REUSED WHERE SHOWN. CAP AND SEAL ALL
UNUSED DUCTWORK AIRTIGHT.
4. CONTRACTOR SHALL BALANCE ALL EX/S71NG DIFFUSERS WITH
CFM'S SHOWN
5. EXISTING RETURN AIR OPENINGS IN SOFFITS AND TRANSFERS
TO REMAIN AND BE REUSED.
6. EXISTING OUTSIDE AIR TO REMAIN AND BE REUSED.
7. EXISTING rSTAT SHALL BE INSPECTED FOR GOOD WORKING
CONDITION. PROVIDE NEW IF REQUIRED. COORDINATE LOCATION
WITH OWNER REPRESENTATIVE
ALL DUCT LINER TRANSVERSE
EDGES TO BE COATED W/
ADHESIVE IN ACCORDANCE
W/ SMACNA STANDARDS
(')
TAPE DOWN EXTERNAL
INSULA770N.
FASTEN WAIN. (3)
SHT. MTL. SCREWS,
SEAL W/ DUCT TAPE
AND MASTIC.
ROUND RIGID OR
FLEXIBLE DUCT.-
1 1/2" WRAPPED INSULATION.
IN AREAS ABOVE CEILING. NO
INSULATION ON DUCT OVER
EXPOSED DECK AREAS.
TYPICAL ROUND DUCT TAKE -OFF DETAIL
SCALE: N. T.S
—DUCT CONNECTION AN REIN-
FORCEMENT IN ACCORDANCE
W/ SMACNA 2" W.G. CLASS,
SEAL NON- GASKETED TRANS-
VERSE JOINTS IN ACCORDANCE
W/ SMACNA CLASS "C" (TYP)
1" ACOUSTICAL
LINING.
CONICAL OR BELLMOUTH SPIN
IN FITTINGS, SEAL 'AIR -71GHT W/
MASTIC.
l'.. ----VOLUME DAMPER AMPER LOCATION
PROVIDE W/ LOCKING QUADRANT
18" LONG ORANGE MARKER
TAPE ATTACHED TO
DAMPER TO IDENTIFY LOCA 7TON.
FILE CO .FY
Permit No.
r - ill
Plan review approval is subject to errors and o ons•
Approval of construction d ents does not authorize
the violation of any adopted code or ordin : Receipt
of approved Field Copy and con ions is acknowledged:
BY
Dater. \1A►'
SEPARATE PERMIT
REQUIRED FOR
❑ Mechanical
dElectrkal
humbing
Was Piping
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal 1
and may include additional plan review fees.
DUCT SIZE OVER 36x36"
SQ. ELBOW WITH TYPE "A"
DOUBLE THICKNESS VANES
SCALE N. T.S
City Of l ikwila
BUILDING DIVISION
VANES PRE ASSEMBLED ON RUNNER PLATES.
USE GALVANIZED VANES FOR GALVANIZED
OR ALUMINUM DUCTS.
PLA7E SAME GUAGE AS DUCTS.
TURNING VANE DETAIL
01
REVIEWED D FOR
CO
NOV 2 4 2009
149
GENERAL LANDLORD NOTES
1. EFFECTIVE JULY 1, 2007 THE CITY OF TUKWILA WILL BE UNDER THE 2006 INTERNATIONAL CODES
AND ALL PERMIT SUBMITTALS NEED TO BE IN CONFORMANCE WI7H THIS EDITION.
2. TENANT'S CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL WITHIN 7HE LANDLORD'S
TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REGULATIONS
3. TENANT SHALL PROPERLY SEAL ALL PENETRATIONS TO COMPLY WITH CODE REQUIREMENTS THE
FIRE, RATED FLOOR ASSEMBLY SHALL BE MAINTAINED. ALL PLUMBING, MECHANICAL AND
ELECTRICAL DEVICES PENETRATING FLOOR SHALL BE FIRE RATED.
4. TENANT ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH
LANDLORD PRIOR TO ANY SLAB DEMOLITION TO PREVENT DISTURBANCE OF LANDLORD'S BELOW
GRADE UTILITIES. ON COMPLETION OF BELOW GRADE WORK, TENANT SHALL BE RESPONSIBLE FOR
RECONSTRUCTION AND PATCHING OF THE SLAB ON GRADE INCLUDING GRAVEL LAYERS, VAPOR
BARRIER AND CONCRETE
TENANTS CONTRACTOR IS TO VERIFY LOCATION; GET APPROVAL AND REQUIREMENTS FOR ALL
TRENCHING Wl7H WESTFIELD'S ON -SITE TENANT COORDINATORS BEFORE PRECEDING WORK
6. TENANTS CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EX77NGU/SHER WHERE
EVERY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE
WATCH SHALL REMAIN IN 7HE TENANT SPACE FOR AT LEAST 1 HOUR AFTER 7HE COMPLETION OF
ANY WELDING. THIS SHALL BE COORDINATED THROUGH 7HE CITY OF TUKWILA.
City of Tukwila
UJLDINO DIVISION
R =2"
DUCT SIZE 36 "x36" OR UNDER
SQ. ELBOW WITH SINGLE
THICKNESS VANES
RECEIVED
NOV 18 2009
PERMIT CENTER
w
0)
DMC STORE #
4083
RELOCATION
ARCHITECT OF RECORD:
C O R T L A N D CWIA
M O R G A N
ARCHITECT
711 NORTH FIELDER ROAD
ARLINGTON, TEXAS 76012
PH: (817) 635 -5696
FAX: (817) 635 -5699
...
J
z J
m
rx
W
fia fg F—
W
F—
0
O
F igInigi
0 4
2
CD
o �
-J
a
C�
CC w
o �
DRAWN BY:
i sm
c,
MECHANICAL
MP1
LC)
0
M
W
< oo
CL
C/)
LU
� Q
J
LU
=
O ~
CA
N-
IX)
0
r
0
HVAC LOAD SUMMARY
EXISTING VAV UNIT
MARK
MANUFACTURER
MODEL
CFM
MOTHERHOOD MATERNITY
SOUTHCENTER MALL
1UKW'LLA, WA
- 1464 SQUARE FEET
65
63
68
1112
70
2000
75
20
0.20
250
+
+
+
+
+
+
ASHRAE DESIGN CONDITIONS
+ COOLING OA DB 85 COOLING OA WB
COOLING IA DB 75 COOLING IA WB
+ HEATING OA 28 HEATING IA
+ ROOF U- FACTOR 0.000 L TS- RECESSED
+ LIGHT DIVERS ** 1.2 9d.TS- RECESSED
VAV MIN AIR 418 MISC. WATTS
+ L TS- SURFACE 2666 SQ FT /PERSON
+ V. TS- SURFACE 100 NO OF PEOPLE
+ WALL AREA 0 WALL U- FACTOR
+ YJ?OOF TO SPACE 70
PEOPLE SENS HEAT 250 PEOPLE LATENT
1200
480/3
- COOLING LOAD SUMMARY
1. SYMBOL KEY- 5. DAMPERS SHALL BE OPERABLE FROM FACE
FIRST LETTER. S- SUPPLY R- RETURN E- EXHAUST "A" OPPOSED BLADE #AG -35
2 CATALOG NUMBERS REFER TO TI1US AIR DEVICES. "B" RADIAL OPPOSED BLADE #D -75.
"C" RUSKIN CFD OR CFDR FIRE DAMPER W /VOLUME CONTROL.
3 PROWDE #DB DIRECTIONAL BLOW FOR OTHER "D" YOUNG'S REGULATOR, DPR MODEL #5020 -CC
THAN 4 -WAY. 6. BORDER STYLE-
"A" SURFACE MOUNTED
4. FINISH- "B" LAY -IN PROVIDE WITH 77TUS MODEL # XY -13363 FRAME
"A" 777US STANDARD WHITE FINISH. FOR. DRYWALL CEILING MOUNTING.
C LAY IN FRAME FOR T- -BAR CEILING.
SYMBOL
SENSIBLE HEAT GAIN LATENT HEAT GAIN
PEOPLE 4880 PEOPLE
VEN11LA710N 0 VENTILATION
ROOF LOAD 0 70Z TO SPACE
LTS- SURFACE 10919 1009 TO SPACE
L TS- RECESSED 3188 70X TO SPACE
MISC LOAD 6826
WALL LOAD 0
4880
0
4880
MATERIAL
TOTAL SENSIBLE 25813 TOTAL LATENT
TOTAL COOLING LOAD ; 30693BTUH
SENS /TOTAL RA710 84 9
NOMINAL CFM (15 DEG F DIFF) 1173 CFM
+ SUPPLY AIR. TEMP 55 DEG F
TEMPERATURE DIFFERENCE 20 DEG F
BORDER
STYLE
REMARKS
MOD.
NECK
CLG.
HEATING LOAD SUMMARY
-
SENSIBLE HEAT GAIN LATENT HEAT GAIN
0
SD -1
VENTILATION 0 VENTILATION
ROOF LOAD 0
WALL LOAD 0
TOTAL SENSIBLE 0 TOTAL LATENT
0
O BTUH
0 KW
3 KW
TOTAL HEATING LOAD
NOMINAL KW ELEC HEAT
MINIMUM KW ELEC HEAT
(BASED ON 20 DEG F RISE @ VAV MIN AIR)
MECHANICAL GENERAL NOTES (As APPLICABLE)
1. IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE
ENGINEER SHALL BE NOT7F/ED IMMEDIA TEL Y.
2 ALL WORK SHALL BE PERFORMED BY QUAUFIED MECHANICS AND PLUMBERS UNDER
THE DIRECTION OF AN EXPERIENCED SUPERVISOR HAVING EXPERIENCE IN INSTALLING
EQUIPMENT AND SYSTEMS OF SIMILAR TYPE AS INDICATED BY THE CONTRACT
DOCUMENTS
3. ALL WORK ` SHALL BE PERFORMED IN ACCORDANCE WITH CURRENT RULES AND
REGULATIONS OF THE STATE AND LOCAL CODES AND IN ACCORDANCE IM7H CURRENT
INDUSTRY STANDARDS
PROVIDE ALL EQUIPMENT MATERIALS, LABOR SUPERVISION, AND SERVICES, NOT
PROVIDED BY THE LANDLORD, AND NECESSARY FOR OR INCIDENTAL TO THE
INSTALLATION OF A COMPLETE AND OPERATING HVAC, FIRE PROTECTION,' AND /OR
PLUMBING SYSTEM AS SHOWN OR INDICATED ON THE DRAWINGS AND /OR AS SPECIFIED.
5 CONTRACTOR SHALL TAKE PROPER PRECAUTIONS TO PROTECT ALL EXIST7NG
OPERATIONS AND PROPERTY ADJACENT, WITH WHICH WORK COMES IN CONTACT OR
OVER WHICH HE /SHE MAY TRANSPORT HOIST, OR MOVE MATERIALS, EQUIPMENT, DEBRIS,
ETC. AND SHALL REPAIR ANY DAMAGE CAUSED TO MATCH EXISTING BEFORE DAMAGE.
771E CONTRACTOR SHALL COORDINATE AND NOTIFY THE BUILDING OWNER AND OPERATOR
FOR APPROVAL, AND SCHEDULING OF ALL BUILDING OR EXISTING TENANT SYSTEM
INTERRUPTION.
6. CONTRACTOR SHALL EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS
IN THEIR EN77RETY AND SURVEY THE PROJECT AND BECOME FAMILIAR WISH THE EXIS77NG
CONDITIONS AND SCOPE OF WORK ALL COSTS SUBMITTED SHALL BE BASED ON A
THOROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY ADDITIONAL
COSTS DUE TO FAILURE TO COMPLY HIM THIS REQUIREMENT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR.
7 VERIFY THE CONDITION AND LOCA710N OF UTILITIES. ANY ITEMS REQUIRING REPAIR
OR RELOCATION SHALL BE REPAIRED TO PROVIDE THE TENANT
A COMPLETE AND OPERATING MECHANICAL SYSTEM. OBTAIN APPROVAL FROM
THE TENANT AND LANDLORD PRIOR TO RELOCATION OF EXISTING SERVICES OR
COMPONENTS. COORDINATE THE RELOCATION OF ANY LANDLORD FURNISHED
EQUIPMENT WITH THE LANDLORD.
PRODUCTS OF A SIMILAR NATURE SHALL BE OF THE SAME TYPE AND MANUFACTURER.
PROWDE THE STANDARD PRODUCTS OF MANUFACTURERS REGULARY ENGAGED IN THE
PRODUCTION OF SPECIFIED PRODUCTS, UNLESS OTHERWISE REQUIRED BY DRAWINGS OR
SPECIFICATIONS. ALL SUCH PRODUCTS SHALL BE LISTED, LABELED, OR CERTIFIED BY
UNDERWRITERS LABORATORIES
9. DRAWINGS ARE DIAGRAMMA77C AND INDICATE GENERAL ARRANGEMENT OF WORK.
10. CONTRACTOR SHALL COORDINATE WORK HUH ALL OTHER TRADES.
11. CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT SITE AND BE RESPONSIBLE FOR
CORRECTNESS OF SAME.
12. CONNECT NEW WORK TO EXISTING CONSTRUCTION IN NEAT AND APPROVED MANNER
RESTORE EXISTING WORK IN MAKING SUCH CONNECTION TO PERFECT CONDITION.
13. ALL WORK SHALL BE INSTALLED READILY ACCESSIBLE FOR OPERA710N, MAINTENANCE
AND REPAIRS.
14. ALL WORK AND EQUIPMENT TO BE FULLY GUARANTEED FOR ONE (1) YEAR FROM THE
DATE OF FINAL PAYMENT AND ACCEPTANCE.
15. ALL CUTTING AND PATCHING IN CONNEC770N WTI THIS TRADE SHALL BE DONE BY
THIS CONTRACTOR UNLESS OTHERWISE NOTED.
16. STORE MATERIALS IN SPACES DESIGNATED BY OWNER.
17. REMOVE RUBBISH FROM PREMISES S0 OFTEN AS NECESSARY OR DIRECTED.
18. EQUIPMENT INTENDED FOR PERMANENT INSTALLATION SHALL NOT BE OPERATED FOR
TEMPORARY PURPOSES.
ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SA77SFAC770N OF THE OWNER
BEFORE TURNING SAME OVER TO OWNER.
20. SHOP DRAWINGS SHALL BE SUBMITTED FOR APPROVAL PRIOR TO ORDERING AND
INSTALLING ANY EQUIPMENT. THE CONTRACTOR MAY SUBMIT FOR APPROVAL, 10
DAYS PRIOR TO PRESENTATION OF NEGOTIATED PRICE TO OWNER, ALTERNATE
MANUFACTURERS OF ALL ITEMS SPECIFIED ON THESE DRAWINGS
21. THE CONTRACTOR SHALL PROVIDE THE A/E TEAM A COMPLETE SET OF "AS- BUILT"
DRAWINGS FOR ALL WORK PERFORMED ON THE PREMISES (REPRODUCIBLE AND A
MINIMUM OF 4 COPIES REQUIRED).
22. SUPPORTS FOR ALL EQUIPMENT AND PIPING SHALL PROVIDE ADEQUATE SLOPE AND
ANCHORAGE, CONTRACTOR SHALL USE HANGERS, RODS AND INSERTS INSTALLED,
CONSTRUCTED, AND SPACED PER MSS REQUIREMENTS
23. ROOF MOUNTED EQUIPMENT SHALL BE MOUNTED ON PREFABRICATED FACTORY SUPPLIED
UNIT CURBS OR EQUIPMENT SUPPORT SIMILAR TO PATE MODELES -1A OR AS REQUIRED BY
LANDLORD.
24. ROOF MOUNTED EQUIPMENT SHALL BE LOCATED IN AREA DESIGNATED BY LANDLORD AS
HAVING SUFFICIENT STEEL STRUCTURE SUPPORT
25. LANDLORD APPROVED STRUCTURAL ENGINEER SHALL VERIFY, CERTIFY, AND SEAL THE
ADEQUACY OF THE EXISTING OR NEW STRUCTURE FOR SUPPORT OF THE PROPOSED HVAC
EQUIPMENT AND SHALL PROVIDE FOR SEALED DRAWINGS AND CALCULA770NS FOR 171E
REQUIRED REINFORCEMENT PRIOR TO INSTALLA770N. ASSOCIATED DESIGN AND
INSTALLATION COSTS ARE TENANT CONTRACTORS RESPONSIBILITY.
26. ROOF PENETRATIONS SHALL BE KEPT TO A MINIMUM
2Z ALL ROOF MEMBRANE MOD/F7CATIONS, REPAIRS, CUTTING, FLASHING,
COUNTER FLASHING, PENETRATIONS AND CURB INSTALLATIONS SHALL BE ENGINEERED
AND INSTALLATION PERFORMED BY A LANDLORD APPROVED ROOFING CONTRACTOR IN
ACCORDANCE W771 LANDLORD'S REQUIREMENTS. ALL ASSOCIATED COSTS ARE TENANT'S
CONTRACTORS' RESPONSIBILITY
28. ALL ROOF CAPS SHALL BE COMPLETE WITH BIRDSCREEN.
29. SEAL ALL PENETRATIONS THRU WALLS, FLOORS AND CEILINGS AIR, WATER, AND
FIRE TIGHT.
30. PROVIDE ACCESS PANELS FOR ALL CONCEALED EQUIPMENT, FIRE DAMPERS, PIPING
VALVES, CLEAN OUTS, ETC.
31. TRENCHING, EXCAVATING, BACK FILLING AND CONCRETE WORK SHALL BE PER OSHA,
LOCAL CODE REQUIREMENTS AND LANDLORD'S CRITERIA.
32 THIS CONTRACTOR IS RESPONSIBLE FOR COORDINATION AND NOTIFICA770N OF
ALL OTHER CONTRACTORS EFFECTED BY ANY EQUIPMENT MODIFICATIONS OR
SUBSTITUTIONS.
33. INSTALL ALL DUCTWORK AND PIPING SO HIGH AS POSSIBLE. ROUTE DUCTS AND
PIPES PARALLEL AND PERPENDICULAR TO WALLS UNLESS OTHERWISE NOTED.
34. VERIFY ALL LANDLORD REQUIREMENTS.
SPRINKLER SYSTEM NOTES (AS APPLICABLE)
1. THE EXIS77NG SPRINKLER SYSTEM SHALL BE MODIFIED AS REQUIRED DUE TO THE NEW
CONSTRUCT7ON TO MEET THE REQUIREMENTS OF NFPA13, THE LOCAL CODE, AND THE
TENANT /LANDLORD'S INSURER. PIPING 'DRAWINGS SHALL BE SUBMITTED TO THE
APPROPRIATE APPROVAL AGENCY AS OUTLINED BY THE CITY SUBMITTAL
REQUIREMENTS THE SPRINKLER CONTRACTOR SHALL BE LICENSED TO DO WORK
IN THIS STATE ALL PIPING "MODIF7CA 710NS REQUIRED WILL BE INCLUDED IN THIS
CONTRACT SPRINKLER HEAD TYPES SHALL BE BUILDING STANDARD (VERIFY WITH
TENANT). SPRINKLER CONTRACTOR SHALL PROVIDE TO THE OWNER AND LANDLORD'S
REPRESENTATIVE A COMPLETE SET OF SPRINKLER DRAWNGS INCLUDING MODIFIED
PIPING LAYOUT AND SPRINKLER LOCATIONS FOR APPROVAL PRIOR TO INSTALLATION.
2 UPON COMPLETION OF THE SPRINKLER SYSTEM, THE SPRINKLER CONTRACTOR SHALL
HYDROSTATIC ALLY TEST ALL PIPING PER NFPA AND LOCAL CODE AUTHORITIES.
PROPERLY Y FILLED OUT 'SPRINKLER CONTRACTOR'S
MATERIAL AND TEST
CERTIFICATES' MUST BE FURNISHED TO THE TENANT AND LANDLORD'S PROJECT
MANAGER AT THE JOB SITE, AND TO 771E TENANT AND LANDLORD'S INSURANCE
RATING BUREAU HAVING JURISDIC770N.
3 ALL SPRINKLER PIPING SHALL MATCH EXIS77NG.
H. VA C. GENERAL NO TES(AS APPLICABLE)
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LABOR AND MATERIALS TO
PROVIDE A COMPLETE AND WORKING SYSTEM WITHIN THE CONSTRAINTS OF THE
EXISTING STRUCTURE AND NEW CEILING SYSTEM.
2. DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED PER ASHRAE AND SMACNA
STANDARDS AND THE STA7E MECHANICAL CODE. THIS INCLUDES (BUT IS NOT
LIMITED TO) SEALING ALL ' DUCTS, SPLI7TERS (OR SIMILAR BALANCING DEVICES)
AT MAJOR DUCTWORK BRANCHES, EXTRACTORS AT MINOR DUCTWORK BRANCHES,
DOUBLE WALLED ACOUSTIC 'TURNING VANES IN ELBOWS, SPLITTERS, AND TURNING
VANES IN TEES.
3 ALL DUCTWORK SHALL BE GALVANIZED SHEET METAL, RECTANGULAR DUCT SHALL
BE INTERNALLY LINED HIM 1" 1 1/2" DUCT LINER, ROUND DUCT SHALL BE WRAPPED
MTH 1 1/2" INSULA710N, FLEX DUCT SHALL BE INSULATED TYPE.
4. EXTERNAL DUCT INSULA110N SHALL BE EQUAL TO OWENS CORNING FIBERGLASS
WITH FRK VAPOR BARRIER. INSTALL PER MANUFACTURER'S RECOMMENDATIONS
THE MINIMUM THICKNESS SHALL BE 1 1/2 ". DUCT LINER SHALL BE EQUAL TO OWENS
CORNING AEROFLEX TYPE 150, 1" THICK.
5. PROVIDE SPIN -IN TAP WITH DAMPER AT EACH RUNOUT TAP.
6. PROVIDE FIRE RESISTANT TYPE FLEXIBLE DUCT CONNECTORS ON THE INLET AND
DISCHARGE DUCT CONNECTIONS OF ALL EQUIPMENT CONTAINING FANS.
7. FLEXIBLE DUCT SHALL NOT EXCEED 5=-0".
8. ALL DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE DIMENSIONS.
9 LOCATE THE THERMOSTAT AND INSTALL AS SHOWN ON THESE DOCUMENTS
10. ALL FLUSH FACE RECTANGULAR CEILING SUPPLY DIFFUSERS SHALL BE 24" x 24" OR
12" x 12" TITUS PAS OR EQUAL UNLESS NOTED OTHERWISE. CFM AND NECK SIZE AS
SHOWN ON DRAWINGS
11. ALL FLUSH FACE RECTANGULAR CEILING RETURN AIR GRILLES SHALL BE TITUS PAR
UNLESS NOTED OTHERWISE. SIZE AS SHOWN ON DRAWINGS SURFACE MOUNT BORDER
TYPE 1, SNAP -IN BORDER TYPE 2, LAY -/N BORDER TYPE 3. SPINE BORDER TYPE 4.
12. CONDENSA 7E DRAIN PIPING SHALL BE TYPE "L" OR "M" HARD DRAWN COPPER WITH
WROUGHT COPPER FITTING.
13. INSULATE CONDENSATE PIPING 14177I 1" THICK FIBERGLASS 144771 ASJ OR 1/2 ARMAFLEX
(PLENUM RATED IF IN RETURN AIR PLENUM).
14. FOR UNITS OF 2000 CFM OR GREATER, PROVIDE MANUAL RESET IONIZA710N TYPE
SMOKE DETECTOR IN RETURN AIR DUCT (IF REQUIRED) AHEAD OF ANY OUTSIDE -AIR INLET
OR IN EACH ROOM OR SPACE SERVED BY THE RETURN AIR -AIR DUCT DETECTORS SHALL
ALSO BE INSTALLED IN THE SUPPLY DUCT, DOWNSTREAM OF THE FILTERS. FOR ALL
UNITS LESS THAN 2000 CFM: PROVIDE MANUAL RESET F1RE SYSTEM. UPON DETECTION
OF PRODUCTS OF COMBUSTION DETECTORS SHALL AC77VA7E AC71VA770N OF ANY
DETECTOR SHALL CAUSE THE AIR - MOVING EQUIPMENT TO AUTOMA77CALLY SHUT DOWN.
15. ALL CONTROL WRING SHALL BE IN CONDUIT
16. REFERENCE ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL
DIFFUSERS.
17 THE MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED BY THE
MECHANICAL CONTRACTOR. TESTS SHALL DETERMINE QUANTITATIVE PERFORMANCE
OF EQUIPMENT, BALANCING SHALL PROPORTION FLOWS WITHIN THE DISTRIBUTION
SYSTEM(S) ACCORDING TO SPECIFIED DESIGN QUANTITIES. ALL WORK SHELL MEET
LOCAL CODES AND STANDARDS, NEBB ASHREA TESTING, ADJUSTING AND BALANCING
PROCEDURES. SUBMIT, TO 171E BUILDING OWNER FOR REVIEW, APPROVAL AND RECORD,
TWO COPIES OF THE BALANCINCING REPORTS ON THE STANDARD REPORT FORMS
PREPARED BY NEBB.
18. ALL EQUIPMENT NAMEPLATE INFORMATION SHALL BE PERMANENTLY AFFIXED TO
EQUIPMENT NAMEPLATE" INFORMATION SHALL BE ETCHED ON METAL NAME PLATES
PLUMBING GENERAL NO TES (AS APPLICABLE)
1. WASTE DRAIN AND VENT PIPING SHALL BE SERVCE WEIGHT CAST IRON, NO HUB
F1T77NGS ARE ACCEPTABLE (ABOVE GROUND ONLY). SCHEDULE 40 GALVANIZED
STEEL OR DVW COPPER MAY BE USED FOR PIPING 1 1/2" OR LESS.
2. POTABLE WATER PIPING SHALL BE TYPE "L" HARD DRAWN COPPER WITH WROUGHT
COPPER F7777NGS.
3. INSULATE HOT AND COLD WATER PIPING WITH 1" THICK OWENS CORNING, FIBERGLASS
25 ASJ JOHN MANSI4LLE AP OR APPROVED EQUAL INSTALLED PER MANUFACTURER'S
REQUIREMENTS. INSULA710N SHALL BE CONTINUOUS THROUGH WALLS, FLOORS,
CEILINGS ETC.
4. THE PLUMBING CONTRACTOR SHALL MAKE ALL NECESSARY ARRANGEMENTS
(APPLICATIONS AND FEES) 141 H THE LOCAL UTILITY COMPANY FOR WATER SERVICE.
5 THE DOMESTIC WATER PIPING SYSTEM SHALL BE STERILIZED PER LOCAL CODE
6. INSULATE CONDENSATE PIPING WITH 1 ", THICK FIBERGLASS 1 ASJ OR 1/2
ARMAFLEX (PLENUM RATED IF IN RETURN AIR PLENUM).
7 PROWDE AIR CHAMBERS T ALL FIXTURES OR SHOCK ABSORBERS AT EACH BATTERY.
8. PROVIDE SECTIONAL SHUT-OFF VALVES ON EACH BRANCH AND RISER, CLOSE TO MAIN,
WHERE; BRANCH OR RISER SERVES 2 OR MORE PLUMBING FIXIURES'OR EQUIPMENT
CONNECTIONS, AND ELSEWHERE AS INDICATED.
9. PROVIDE SHUTOFF VALVES AT INLET OF EACH PLUMBING EQUIPMENT ITEM, AND AT
INLET OF EACH PLUMBING FIXTURE, AND ELSEWHERE AS INDICATED.
10. INSTALL CLEANOUTS IN DRAIN PIPING AS INDICATED, AND AS REQUIRED BY LOCAL
PLUMBING CODE AT EACH CHANGE IN DIRECTION OF PIPING GREATER THAN 45 DEG,
AT MINIMUM INTERVALS OF 50' FOR PIPING AND SMALLER AND 100' FOR LARGER
PIPING, AND AT BASE OF EACH CONDUCTOR. INSTALL FLOOR AND WALL CLEANOUT
COVERS FOR CONCEALED PIPING, SELECT TYPE TO MATCH ADJACENT BUILDING FINISH
(VERIFY SELECTION WITH TENANT PRIOR TO ORDERING)
11. INSULATE ALL EXPOSED SANITARY AND WATER PIPING AT ALL HANDICAP RATED
LAVATORIES 1417H FULLY MOLDED, TRUEBRO, HAND! LA V GUARD INSULA 770N KIT
MODEL #102
12 PROVIDE CAST BRASS OR CHROME ESCUTCHEONS WITH SET SCREW, DEEP TYPE, TO
COVER SLEEVES OR OF A SIZE TO COVER FITTING PROJECTIONS. PROVIDE ESCUTCHEONS
FOR ALL EXPOSED PIPING THROUGH WALLS, FLOORS AND EXPOSED CEILING
13 MAXIMUM HOT WATER TO PUBLIC LAYS TO BE 110 DEG AT 5 GPM FLOW PER CEC.
14 MINIMUM SLOPE OF HORIZONTAL WASTE LINES TO BE 1/4" PER FOOT
LANDLORD NOTES
ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE
WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB
DEMOLITION. TENANT SHALL COORDINATE !MTH LANDLORD TO
PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION' AND
PHOTOGRAPHIC DOCUMENTA770N`BY LANDLORD OF BELOW GRADE
WORK PRIOR TO THE COVERING UP OF SUCH WORK TENANT
SHALL BE RESPONSIBLE FOR RECONSTRUCT7ON AND PATCHING' OF
THE SLAB-ON-GRADE SYSTEM, INCLUDING GRAVEL LAYERS,
VAPOR BARRIER, AND CONCRETE.
2. TENANT SHALL PROVIDE AND INSTALL A REDUCED PRESSURE
BACKFLOW PREVENTER ON THEIR WATER SERVICE WITHIN THEIR
SPACE PRIOR TO MAKING ANY OTHER CONNECT7ONS TO THE
WATER SERIIICE PIPING.
3. WATER PIPING SHALL BE "TYPE L" HARD COPPER TUBE ABOVE
GRADE AND "TYPE K" SOFT COPPER TUBE BELOW GRADE.
4. SANITARY WASTE AND VENT PIPING SHALL NE CAST IRON WITH
"NO HUB" COUPLINGS.
5. TENANT'S CONTRACTOR SHALL VERIFY POINTS OF CONNECTION
FOR ALL VENT, SEWER, AND WATER PIPING WITH MALL
MANAGEMENT BEFORE PROCEEDING WITH WORK. TENANT IS
RESPONSIBLE FOR EXTENDING PIPING FROM PO /NT OF EXISTING
CONNECTIONS TO TENANT SPACE AT TENANT'S EXPENSE
GENERAL LANDLORD NOTES
1 EFFECTIVE JULY 1, 2007 THE CITY OF TUKWILA MILL BE UNDER
THE 2006 INTERNATIONAL CODES AND ALL PERMIT SUBMITTALS
NEED TO BE IN CONFORMANCE Wl7H THIS EDITION.
2. TENANT'S CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE !44TH
ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL
INCLUDING ITS RULES AND REGULATIONS.
3. TENANT SHALL PROPERLY SEAL ALL PENET?A 77ONS TO COMPLY
WITH CODE REQUIREMENTS. THE FIRE RATED FLOOR ASSEMBLY
SHALL BE MAINTAINED. ALL PLUMBING, MECHANICAL AND
ELECTRICAL DEICES PENETRATING FLOOR SHALL BE FIRE RATED.
4. TENANT ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK
SHALL COORDINATE 114771 LANDLORD PRIOR TO ANY SLAB
DEMOLITION TO PREVENT DISTURBANCE OF LANDLORD'S BELOW
GRADE UTILITIES. ON COMPLETION OF BELOW GRADE WORK,
TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND
PATCHING OF THE SLAB ON GRADE INCLUDING GRAVEL LAYERS,
VAPOR BARRIER AND CONCRETE.
5. TENANTS CONTRACTOR IS TO VERIFY LOCH 770N; GET APPROVAL
AND REQUIREMENTS FOR ALL TRENCHING 447771 WESTFIELD'S
ON -SITE TENANT COORDINATORS BEFORE PRECEDING WORK.
TENANTS CONTRACTOR SHALL PROVIDE A FIRE WATCH AND
PORTABLE FIRE EX77NGUISHER WHERE EVERY WELDING IS DONE
WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE
FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT
LEAST 1 HOUR AFTER THE COMPLETION OF ANY WELDING. THIS
SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA.
HANGERS
INSTALLED
EACH SIDE
OF EXP. TANK
FOR SUPPORT
AMTROL ST -5
THERMAL
EXPANSION
ABSORBER
VACUUM TYPE
RELIEF VALVE'`
CW
SCALE O = 1 - O "
3/4"
HW
3/4"
GATE VALVE (TYP.)
3/4" RUN FULL
SIZE TO MOP
SINK.
UNION (TYP).
DRAIN VALVE.
PLATFORM OR SHELF
BY GEN. CONTR r
\\ \\
SET INTERNAL ADJUSTABLE
THERMOSTAT (LOCATED
BEHIND COVER) TO -110' F
OUTPUT.
WATER HEATER DETAIL
WCO
MB
PLUMBING PLAN
SCALE 1/4" = 1' -0"
SCALE N.T.S.
LA V
I
0
GAL V. DRIP PAN.
SEPARATE 3/4"
COPPER PIPES
DRAIN TO MOP
SINK.
TO EXIST. SAN STUB
FIELD VERIFY EXACT
LOCATION OF FLOW
1 /2'HW
WATER RISER DIAGRAM
INSULATE ALL PIPING
IN ACCORDANCE 1447H
SPECIFICATIONS
3/ 4" T&P R
EUEF VALVE:
WATER HEATER. SEE
EQUIPMENT SPEC.
- 2" WIDE, 20 GA. SHEET
METAL BAND, SECURE
TO WALL FOR SEISMIC
BRACING WHERE REQ'D
BY CODE
1 /2"CW TO FLOOR
DRAIN TRAP
2 "V I
LL INCOMING
3/4" C.W.
2 "V
2 "V / 2 "VI
SANITARY RISER DIAGRAM
VENT TO ROOF
NOq- ILE 9
3 "
VTR
3 "
REVIEWED FOR
CODE COMPLIANCE
APP ENE
NOV Z 4 21109
EXTEND 4" S.S.
TO EXIS77NG
5..5. V.I.F.
City of Tukwila
BUILDING DIVISt l l
RECEIVED
NOV 1 8 2009
PERMIT CENTER
DMC STORE #
4083
RELOCATION
ARCHITECT OF RECORD:
G O R T L A N D CWIA
M 0 R G A N
ARCHITECT
711 NORTH FIELDER ROAD
ARLINGTON, TEXAS 76012
PH: (817) 635 -5696
FAX: (817) 635 -5699
co
O_
U
w
0
z
kk
w
M
✓
W
Q � �
I lin ini C W Z H z = U zic
O i_
CA O F_.
E ffignaMei In CO
0
0 a
E
DRAWN BY: C.M.
MECHANICAL
SPEC.'S & DETAILS
MP1.1
EXISTING VAV UNIT
MARK
MANUFACTURER
MODEL
CFM
VOLT /PHASE
VAV-1
--
--
1200
480/3
AIR ISTRIBUTION DEVICE SCHEDULE
1. SYMBOL KEY- 5. DAMPERS SHALL BE OPERABLE FROM FACE
FIRST LETTER. S- SUPPLY R- RETURN E- EXHAUST "A" OPPOSED BLADE #AG -35
2 CATALOG NUMBERS REFER TO TI1US AIR DEVICES. "B" RADIAL OPPOSED BLADE #D -75.
"C" RUSKIN CFD OR CFDR FIRE DAMPER W /VOLUME CONTROL.
3 PROWDE #DB DIRECTIONAL BLOW FOR OTHER "D" YOUNG'S REGULATOR, DPR MODEL #5020 -CC
THAN 4 -WAY. 6. BORDER STYLE-
"A" SURFACE MOUNTED
4. FINISH- "B" LAY -IN PROVIDE WITH 77TUS MODEL # XY -13363 FRAME
"A" 777US STANDARD WHITE FINISH. FOR. DRYWALL CEILING MOUNTING.
C LAY IN FRAME FOR T- -BAR CEILING.
SYMBOL
CATALOG
NUMBER
SIZE
MOUNTING
MATERIAL
FINISH
DPR.
BORDER
STYLE
REMARKS
MOD.
NECK
CLG.
OTHER
STEEL
ALUM.
SD -1
TMS
24 "x24"
12 "0
LAY-IN
SD -1
TMS
12"x12"
6 "0
®
A
B
C
LAY-IN
RG -1
25 RL
24"x24"
22"x22"
®
o
A
C
LAY -IN
RG -1
25 RL
12"x12"
10 "x10"
o
0
A
C
LAY -IN
PLUMBING MBI
U G FIXTURE SCHEDULE
MANUFACTURER
MARK FIXTURE AND MODEL Na CW HW WASTE TRAP REMARKS
WC
WATER
CLOSET
AMERICAN
STANDARD
NO. 2108.408
1/2"
- -
4"
- -
INTEGRAL HANDICAP TANK TYPE, ELONGATED
WATER SAVER CADET, CHURCH NO. 534.016 SOLID
TOP (LID) SEAT, 3/8" C.P. SUPPLY WITH LOOSE
KEY STOP, 1.6 GAL. FLUSH - 18" MTG HT TO
BOWL, (A.D.A. COMPLIANT).
LAV
LAVATORY
AMERICAN
STANDARD
NI. 0321.075
1/2"
1/2"
1 1/2"
1 1/2"
WALL MOUNTED DECLYN I4IREOUS CHINA 144TH
4" CENTERS, CERAMIX 2000.100 FAUCET NO.
7719.016 GRID DRAIN WITH 1 1/4" T.P., 1 1/4" C.P.
17 GA. "P" TRAP, 3/8" C.P. SUPPLIES WITH LOOSE
KEY STOPS, JOSAM FLOOR MOUNTED CARRIER,
SINGLE LEVER A.D.A. AND ANSI A117.1 APPROVED.
INSULATE DRAIN AND SUPPLY LINES 1447H 1/2"
ARMSTRONG "ARMAFLEX" PIPING INSULATION.
FD
FLOOR
DRAIN
JOSAM
NO. 30003 -A -50
1/2"
- -
3"
3"
3" HUH NIKALOY STRAINER AND PRIMER TRAP.
DF
DRINKING
FOUNTAIN
OASIS (OR EQUAL)
MODEL "P8AMSL"
1/2"
- -
1 1/2"
1 1/2"
NON - REFRIGERATED DRINKING FOUNTAIN,
3 PUSH PAD ACTIVATION, MEETS A.D.A.
REQUIREMENTS. SET TOP OF SPOUT
OUTLETS AT 36" AND 42 " ABOVE
FINISHED FLOOR. PROWDE WITH WALL
HANGER PLATE AND SUPPLY STOP.
MB
MOP
BASIN
FIAT
NO. MSB -2424
1/2"
1/2"
3"
1 1/2"
MOLDED STONE WITH VINYL BUMPER GUARD.
FURNISH WITH AN AMERICAN STANDARD
#8344.111 FAUCET WITH INTEGRAL VACUUM
BREAKER AND STOPS AND WITH A FIAT
#QDC -3 -2 FOR 2" DRAIN CONNEC770N.
MECHANICAL GENERAL NOTES (As APPLICABLE)
1. IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE
ENGINEER SHALL BE NOT7F/ED IMMEDIA TEL Y.
2 ALL WORK SHALL BE PERFORMED BY QUAUFIED MECHANICS AND PLUMBERS UNDER
THE DIRECTION OF AN EXPERIENCED SUPERVISOR HAVING EXPERIENCE IN INSTALLING
EQUIPMENT AND SYSTEMS OF SIMILAR TYPE AS INDICATED BY THE CONTRACT
DOCUMENTS
3. ALL WORK ` SHALL BE PERFORMED IN ACCORDANCE WITH CURRENT RULES AND
REGULATIONS OF THE STATE AND LOCAL CODES AND IN ACCORDANCE IM7H CURRENT
INDUSTRY STANDARDS
PROVIDE ALL EQUIPMENT MATERIALS, LABOR SUPERVISION, AND SERVICES, NOT
PROVIDED BY THE LANDLORD, AND NECESSARY FOR OR INCIDENTAL TO THE
INSTALLATION OF A COMPLETE AND OPERATING HVAC, FIRE PROTECTION,' AND /OR
PLUMBING SYSTEM AS SHOWN OR INDICATED ON THE DRAWINGS AND /OR AS SPECIFIED.
5 CONTRACTOR SHALL TAKE PROPER PRECAUTIONS TO PROTECT ALL EXIST7NG
OPERATIONS AND PROPERTY ADJACENT, WITH WHICH WORK COMES IN CONTACT OR
OVER WHICH HE /SHE MAY TRANSPORT HOIST, OR MOVE MATERIALS, EQUIPMENT, DEBRIS,
ETC. AND SHALL REPAIR ANY DAMAGE CAUSED TO MATCH EXISTING BEFORE DAMAGE.
771E CONTRACTOR SHALL COORDINATE AND NOTIFY THE BUILDING OWNER AND OPERATOR
FOR APPROVAL, AND SCHEDULING OF ALL BUILDING OR EXISTING TENANT SYSTEM
INTERRUPTION.
6. CONTRACTOR SHALL EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS
IN THEIR EN77RETY AND SURVEY THE PROJECT AND BECOME FAMILIAR WISH THE EXIS77NG
CONDITIONS AND SCOPE OF WORK ALL COSTS SUBMITTED SHALL BE BASED ON A
THOROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY ADDITIONAL
COSTS DUE TO FAILURE TO COMPLY HIM THIS REQUIREMENT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR.
7 VERIFY THE CONDITION AND LOCA710N OF UTILITIES. ANY ITEMS REQUIRING REPAIR
OR RELOCATION SHALL BE REPAIRED TO PROVIDE THE TENANT
A COMPLETE AND OPERATING MECHANICAL SYSTEM. OBTAIN APPROVAL FROM
THE TENANT AND LANDLORD PRIOR TO RELOCATION OF EXISTING SERVICES OR
COMPONENTS. COORDINATE THE RELOCATION OF ANY LANDLORD FURNISHED
EQUIPMENT WITH THE LANDLORD.
PRODUCTS OF A SIMILAR NATURE SHALL BE OF THE SAME TYPE AND MANUFACTURER.
PROWDE THE STANDARD PRODUCTS OF MANUFACTURERS REGULARY ENGAGED IN THE
PRODUCTION OF SPECIFIED PRODUCTS, UNLESS OTHERWISE REQUIRED BY DRAWINGS OR
SPECIFICATIONS. ALL SUCH PRODUCTS SHALL BE LISTED, LABELED, OR CERTIFIED BY
UNDERWRITERS LABORATORIES
9. DRAWINGS ARE DIAGRAMMA77C AND INDICATE GENERAL ARRANGEMENT OF WORK.
10. CONTRACTOR SHALL COORDINATE WORK HUH ALL OTHER TRADES.
11. CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT SITE AND BE RESPONSIBLE FOR
CORRECTNESS OF SAME.
12. CONNECT NEW WORK TO EXISTING CONSTRUCTION IN NEAT AND APPROVED MANNER
RESTORE EXISTING WORK IN MAKING SUCH CONNECTION TO PERFECT CONDITION.
13. ALL WORK SHALL BE INSTALLED READILY ACCESSIBLE FOR OPERA710N, MAINTENANCE
AND REPAIRS.
14. ALL WORK AND EQUIPMENT TO BE FULLY GUARANTEED FOR ONE (1) YEAR FROM THE
DATE OF FINAL PAYMENT AND ACCEPTANCE.
15. ALL CUTTING AND PATCHING IN CONNEC770N WTI THIS TRADE SHALL BE DONE BY
THIS CONTRACTOR UNLESS OTHERWISE NOTED.
16. STORE MATERIALS IN SPACES DESIGNATED BY OWNER.
17. REMOVE RUBBISH FROM PREMISES S0 OFTEN AS NECESSARY OR DIRECTED.
18. EQUIPMENT INTENDED FOR PERMANENT INSTALLATION SHALL NOT BE OPERATED FOR
TEMPORARY PURPOSES.
ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SA77SFAC770N OF THE OWNER
BEFORE TURNING SAME OVER TO OWNER.
20. SHOP DRAWINGS SHALL BE SUBMITTED FOR APPROVAL PRIOR TO ORDERING AND
INSTALLING ANY EQUIPMENT. THE CONTRACTOR MAY SUBMIT FOR APPROVAL, 10
DAYS PRIOR TO PRESENTATION OF NEGOTIATED PRICE TO OWNER, ALTERNATE
MANUFACTURERS OF ALL ITEMS SPECIFIED ON THESE DRAWINGS
21. THE CONTRACTOR SHALL PROVIDE THE A/E TEAM A COMPLETE SET OF "AS- BUILT"
DRAWINGS FOR ALL WORK PERFORMED ON THE PREMISES (REPRODUCIBLE AND A
MINIMUM OF 4 COPIES REQUIRED).
22. SUPPORTS FOR ALL EQUIPMENT AND PIPING SHALL PROVIDE ADEQUATE SLOPE AND
ANCHORAGE, CONTRACTOR SHALL USE HANGERS, RODS AND INSERTS INSTALLED,
CONSTRUCTED, AND SPACED PER MSS REQUIREMENTS
23. ROOF MOUNTED EQUIPMENT SHALL BE MOUNTED ON PREFABRICATED FACTORY SUPPLIED
UNIT CURBS OR EQUIPMENT SUPPORT SIMILAR TO PATE MODELES -1A OR AS REQUIRED BY
LANDLORD.
24. ROOF MOUNTED EQUIPMENT SHALL BE LOCATED IN AREA DESIGNATED BY LANDLORD AS
HAVING SUFFICIENT STEEL STRUCTURE SUPPORT
25. LANDLORD APPROVED STRUCTURAL ENGINEER SHALL VERIFY, CERTIFY, AND SEAL THE
ADEQUACY OF THE EXISTING OR NEW STRUCTURE FOR SUPPORT OF THE PROPOSED HVAC
EQUIPMENT AND SHALL PROVIDE FOR SEALED DRAWINGS AND CALCULA770NS FOR 171E
REQUIRED REINFORCEMENT PRIOR TO INSTALLA770N. ASSOCIATED DESIGN AND
INSTALLATION COSTS ARE TENANT CONTRACTORS RESPONSIBILITY.
26. ROOF PENETRATIONS SHALL BE KEPT TO A MINIMUM
2Z ALL ROOF MEMBRANE MOD/F7CATIONS, REPAIRS, CUTTING, FLASHING,
COUNTER FLASHING, PENETRATIONS AND CURB INSTALLATIONS SHALL BE ENGINEERED
AND INSTALLATION PERFORMED BY A LANDLORD APPROVED ROOFING CONTRACTOR IN
ACCORDANCE W771 LANDLORD'S REQUIREMENTS. ALL ASSOCIATED COSTS ARE TENANT'S
CONTRACTORS' RESPONSIBILITY
28. ALL ROOF CAPS SHALL BE COMPLETE WITH BIRDSCREEN.
29. SEAL ALL PENETRATIONS THRU WALLS, FLOORS AND CEILINGS AIR, WATER, AND
FIRE TIGHT.
30. PROVIDE ACCESS PANELS FOR ALL CONCEALED EQUIPMENT, FIRE DAMPERS, PIPING
VALVES, CLEAN OUTS, ETC.
31. TRENCHING, EXCAVATING, BACK FILLING AND CONCRETE WORK SHALL BE PER OSHA,
LOCAL CODE REQUIREMENTS AND LANDLORD'S CRITERIA.
32 THIS CONTRACTOR IS RESPONSIBLE FOR COORDINATION AND NOTIFICA770N OF
ALL OTHER CONTRACTORS EFFECTED BY ANY EQUIPMENT MODIFICATIONS OR
SUBSTITUTIONS.
33. INSTALL ALL DUCTWORK AND PIPING SO HIGH AS POSSIBLE. ROUTE DUCTS AND
PIPES PARALLEL AND PERPENDICULAR TO WALLS UNLESS OTHERWISE NOTED.
34. VERIFY ALL LANDLORD REQUIREMENTS.
SPRINKLER SYSTEM NOTES (AS APPLICABLE)
1. THE EXIS77NG SPRINKLER SYSTEM SHALL BE MODIFIED AS REQUIRED DUE TO THE NEW
CONSTRUCT7ON TO MEET THE REQUIREMENTS OF NFPA13, THE LOCAL CODE, AND THE
TENANT /LANDLORD'S INSURER. PIPING 'DRAWINGS SHALL BE SUBMITTED TO THE
APPROPRIATE APPROVAL AGENCY AS OUTLINED BY THE CITY SUBMITTAL
REQUIREMENTS THE SPRINKLER CONTRACTOR SHALL BE LICENSED TO DO WORK
IN THIS STATE ALL PIPING "MODIF7CA 710NS REQUIRED WILL BE INCLUDED IN THIS
CONTRACT SPRINKLER HEAD TYPES SHALL BE BUILDING STANDARD (VERIFY WITH
TENANT). SPRINKLER CONTRACTOR SHALL PROVIDE TO THE OWNER AND LANDLORD'S
REPRESENTATIVE A COMPLETE SET OF SPRINKLER DRAWNGS INCLUDING MODIFIED
PIPING LAYOUT AND SPRINKLER LOCATIONS FOR APPROVAL PRIOR TO INSTALLATION.
2 UPON COMPLETION OF THE SPRINKLER SYSTEM, THE SPRINKLER CONTRACTOR SHALL
HYDROSTATIC ALLY TEST ALL PIPING PER NFPA AND LOCAL CODE AUTHORITIES.
PROPERLY Y FILLED OUT 'SPRINKLER CONTRACTOR'S
MATERIAL AND TEST
CERTIFICATES' MUST BE FURNISHED TO THE TENANT AND LANDLORD'S PROJECT
MANAGER AT THE JOB SITE, AND TO 771E TENANT AND LANDLORD'S INSURANCE
RATING BUREAU HAVING JURISDIC770N.
3 ALL SPRINKLER PIPING SHALL MATCH EXIS77NG.
H. VA C. GENERAL NO TES(AS APPLICABLE)
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LABOR AND MATERIALS TO
PROVIDE A COMPLETE AND WORKING SYSTEM WITHIN THE CONSTRAINTS OF THE
EXISTING STRUCTURE AND NEW CEILING SYSTEM.
2. DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED PER ASHRAE AND SMACNA
STANDARDS AND THE STA7E MECHANICAL CODE. THIS INCLUDES (BUT IS NOT
LIMITED TO) SEALING ALL ' DUCTS, SPLI7TERS (OR SIMILAR BALANCING DEVICES)
AT MAJOR DUCTWORK BRANCHES, EXTRACTORS AT MINOR DUCTWORK BRANCHES,
DOUBLE WALLED ACOUSTIC 'TURNING VANES IN ELBOWS, SPLITTERS, AND TURNING
VANES IN TEES.
3 ALL DUCTWORK SHALL BE GALVANIZED SHEET METAL, RECTANGULAR DUCT SHALL
BE INTERNALLY LINED HIM 1" 1 1/2" DUCT LINER, ROUND DUCT SHALL BE WRAPPED
MTH 1 1/2" INSULA710N, FLEX DUCT SHALL BE INSULATED TYPE.
4. EXTERNAL DUCT INSULA110N SHALL BE EQUAL TO OWENS CORNING FIBERGLASS
WITH FRK VAPOR BARRIER. INSTALL PER MANUFACTURER'S RECOMMENDATIONS
THE MINIMUM THICKNESS SHALL BE 1 1/2 ". DUCT LINER SHALL BE EQUAL TO OWENS
CORNING AEROFLEX TYPE 150, 1" THICK.
5. PROVIDE SPIN -IN TAP WITH DAMPER AT EACH RUNOUT TAP.
6. PROVIDE FIRE RESISTANT TYPE FLEXIBLE DUCT CONNECTORS ON THE INLET AND
DISCHARGE DUCT CONNECTIONS OF ALL EQUIPMENT CONTAINING FANS.
7. FLEXIBLE DUCT SHALL NOT EXCEED 5=-0".
8. ALL DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE DIMENSIONS.
9 LOCATE THE THERMOSTAT AND INSTALL AS SHOWN ON THESE DOCUMENTS
10. ALL FLUSH FACE RECTANGULAR CEILING SUPPLY DIFFUSERS SHALL BE 24" x 24" OR
12" x 12" TITUS PAS OR EQUAL UNLESS NOTED OTHERWISE. CFM AND NECK SIZE AS
SHOWN ON DRAWINGS
11. ALL FLUSH FACE RECTANGULAR CEILING RETURN AIR GRILLES SHALL BE TITUS PAR
UNLESS NOTED OTHERWISE. SIZE AS SHOWN ON DRAWINGS SURFACE MOUNT BORDER
TYPE 1, SNAP -IN BORDER TYPE 2, LAY -/N BORDER TYPE 3. SPINE BORDER TYPE 4.
12. CONDENSA 7E DRAIN PIPING SHALL BE TYPE "L" OR "M" HARD DRAWN COPPER WITH
WROUGHT COPPER FITTING.
13. INSULATE CONDENSATE PIPING 14177I 1" THICK FIBERGLASS 144771 ASJ OR 1/2 ARMAFLEX
(PLENUM RATED IF IN RETURN AIR PLENUM).
14. FOR UNITS OF 2000 CFM OR GREATER, PROVIDE MANUAL RESET IONIZA710N TYPE
SMOKE DETECTOR IN RETURN AIR DUCT (IF REQUIRED) AHEAD OF ANY OUTSIDE -AIR INLET
OR IN EACH ROOM OR SPACE SERVED BY THE RETURN AIR -AIR DUCT DETECTORS SHALL
ALSO BE INSTALLED IN THE SUPPLY DUCT, DOWNSTREAM OF THE FILTERS. FOR ALL
UNITS LESS THAN 2000 CFM: PROVIDE MANUAL RESET F1RE SYSTEM. UPON DETECTION
OF PRODUCTS OF COMBUSTION DETECTORS SHALL AC77VA7E AC71VA770N OF ANY
DETECTOR SHALL CAUSE THE AIR - MOVING EQUIPMENT TO AUTOMA77CALLY SHUT DOWN.
15. ALL CONTROL WRING SHALL BE IN CONDUIT
16. REFERENCE ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL
DIFFUSERS.
17 THE MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED BY THE
MECHANICAL CONTRACTOR. TESTS SHALL DETERMINE QUANTITATIVE PERFORMANCE
OF EQUIPMENT, BALANCING SHALL PROPORTION FLOWS WITHIN THE DISTRIBUTION
SYSTEM(S) ACCORDING TO SPECIFIED DESIGN QUANTITIES. ALL WORK SHELL MEET
LOCAL CODES AND STANDARDS, NEBB ASHREA TESTING, ADJUSTING AND BALANCING
PROCEDURES. SUBMIT, TO 171E BUILDING OWNER FOR REVIEW, APPROVAL AND RECORD,
TWO COPIES OF THE BALANCINCING REPORTS ON THE STANDARD REPORT FORMS
PREPARED BY NEBB.
18. ALL EQUIPMENT NAMEPLATE INFORMATION SHALL BE PERMANENTLY AFFIXED TO
EQUIPMENT NAMEPLATE" INFORMATION SHALL BE ETCHED ON METAL NAME PLATES
PLUMBING GENERAL NO TES (AS APPLICABLE)
1. WASTE DRAIN AND VENT PIPING SHALL BE SERVCE WEIGHT CAST IRON, NO HUB
F1T77NGS ARE ACCEPTABLE (ABOVE GROUND ONLY). SCHEDULE 40 GALVANIZED
STEEL OR DVW COPPER MAY BE USED FOR PIPING 1 1/2" OR LESS.
2. POTABLE WATER PIPING SHALL BE TYPE "L" HARD DRAWN COPPER WITH WROUGHT
COPPER F7777NGS.
3. INSULATE HOT AND COLD WATER PIPING WITH 1" THICK OWENS CORNING, FIBERGLASS
25 ASJ JOHN MANSI4LLE AP OR APPROVED EQUAL INSTALLED PER MANUFACTURER'S
REQUIREMENTS. INSULA710N SHALL BE CONTINUOUS THROUGH WALLS, FLOORS,
CEILINGS ETC.
4. THE PLUMBING CONTRACTOR SHALL MAKE ALL NECESSARY ARRANGEMENTS
(APPLICATIONS AND FEES) 141 H THE LOCAL UTILITY COMPANY FOR WATER SERVICE.
5 THE DOMESTIC WATER PIPING SYSTEM SHALL BE STERILIZED PER LOCAL CODE
6. INSULATE CONDENSATE PIPING WITH 1 ", THICK FIBERGLASS 1 ASJ OR 1/2
ARMAFLEX (PLENUM RATED IF IN RETURN AIR PLENUM).
7 PROWDE AIR CHAMBERS T ALL FIXTURES OR SHOCK ABSORBERS AT EACH BATTERY.
8. PROVIDE SECTIONAL SHUT-OFF VALVES ON EACH BRANCH AND RISER, CLOSE TO MAIN,
WHERE; BRANCH OR RISER SERVES 2 OR MORE PLUMBING FIXIURES'OR EQUIPMENT
CONNECTIONS, AND ELSEWHERE AS INDICATED.
9. PROVIDE SHUTOFF VALVES AT INLET OF EACH PLUMBING EQUIPMENT ITEM, AND AT
INLET OF EACH PLUMBING FIXTURE, AND ELSEWHERE AS INDICATED.
10. INSTALL CLEANOUTS IN DRAIN PIPING AS INDICATED, AND AS REQUIRED BY LOCAL
PLUMBING CODE AT EACH CHANGE IN DIRECTION OF PIPING GREATER THAN 45 DEG,
AT MINIMUM INTERVALS OF 50' FOR PIPING AND SMALLER AND 100' FOR LARGER
PIPING, AND AT BASE OF EACH CONDUCTOR. INSTALL FLOOR AND WALL CLEANOUT
COVERS FOR CONCEALED PIPING, SELECT TYPE TO MATCH ADJACENT BUILDING FINISH
(VERIFY SELECTION WITH TENANT PRIOR TO ORDERING)
11. INSULATE ALL EXPOSED SANITARY AND WATER PIPING AT ALL HANDICAP RATED
LAVATORIES 1417H FULLY MOLDED, TRUEBRO, HAND! LA V GUARD INSULA 770N KIT
MODEL #102
12 PROVIDE CAST BRASS OR CHROME ESCUTCHEONS WITH SET SCREW, DEEP TYPE, TO
COVER SLEEVES OR OF A SIZE TO COVER FITTING PROJECTIONS. PROVIDE ESCUTCHEONS
FOR ALL EXPOSED PIPING THROUGH WALLS, FLOORS AND EXPOSED CEILING
13 MAXIMUM HOT WATER TO PUBLIC LAYS TO BE 110 DEG AT 5 GPM FLOW PER CEC.
14 MINIMUM SLOPE OF HORIZONTAL WASTE LINES TO BE 1/4" PER FOOT
LANDLORD NOTES
ALL TENANTS ON THE GROUND FLOOR REQUIRING BELOW GRADE
WORK SHALL COORDINATE WITH LANDLORD PRIOR TO ANY SLAB
DEMOLITION. TENANT SHALL COORDINATE !MTH LANDLORD TO
PROVIDE OPPORTUNITY FOR SPECIAL INSPECTION' AND
PHOTOGRAPHIC DOCUMENTA770N`BY LANDLORD OF BELOW GRADE
WORK PRIOR TO THE COVERING UP OF SUCH WORK TENANT
SHALL BE RESPONSIBLE FOR RECONSTRUCT7ON AND PATCHING' OF
THE SLAB-ON-GRADE SYSTEM, INCLUDING GRAVEL LAYERS,
VAPOR BARRIER, AND CONCRETE.
2. TENANT SHALL PROVIDE AND INSTALL A REDUCED PRESSURE
BACKFLOW PREVENTER ON THEIR WATER SERVICE WITHIN THEIR
SPACE PRIOR TO MAKING ANY OTHER CONNECT7ONS TO THE
WATER SERIIICE PIPING.
3. WATER PIPING SHALL BE "TYPE L" HARD COPPER TUBE ABOVE
GRADE AND "TYPE K" SOFT COPPER TUBE BELOW GRADE.
4. SANITARY WASTE AND VENT PIPING SHALL NE CAST IRON WITH
"NO HUB" COUPLINGS.
5. TENANT'S CONTRACTOR SHALL VERIFY POINTS OF CONNECTION
FOR ALL VENT, SEWER, AND WATER PIPING WITH MALL
MANAGEMENT BEFORE PROCEEDING WITH WORK. TENANT IS
RESPONSIBLE FOR EXTENDING PIPING FROM PO /NT OF EXISTING
CONNECTIONS TO TENANT SPACE AT TENANT'S EXPENSE
GENERAL LANDLORD NOTES
1 EFFECTIVE JULY 1, 2007 THE CITY OF TUKWILA MILL BE UNDER
THE 2006 INTERNATIONAL CODES AND ALL PERMIT SUBMITTALS
NEED TO BE IN CONFORMANCE Wl7H THIS EDITION.
2. TENANT'S CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE !44TH
ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL
INCLUDING ITS RULES AND REGULATIONS.
3. TENANT SHALL PROPERLY SEAL ALL PENET?A 77ONS TO COMPLY
WITH CODE REQUIREMENTS. THE FIRE RATED FLOOR ASSEMBLY
SHALL BE MAINTAINED. ALL PLUMBING, MECHANICAL AND
ELECTRICAL DEICES PENETRATING FLOOR SHALL BE FIRE RATED.
4. TENANT ON THE GROUND FLOOR REQUIRING BELOW GRADE WORK
SHALL COORDINATE 114771 LANDLORD PRIOR TO ANY SLAB
DEMOLITION TO PREVENT DISTURBANCE OF LANDLORD'S BELOW
GRADE UTILITIES. ON COMPLETION OF BELOW GRADE WORK,
TENANT SHALL BE RESPONSIBLE FOR RECONSTRUCTION AND
PATCHING OF THE SLAB ON GRADE INCLUDING GRAVEL LAYERS,
VAPOR BARRIER AND CONCRETE.
5. TENANTS CONTRACTOR IS TO VERIFY LOCH 770N; GET APPROVAL
AND REQUIREMENTS FOR ALL TRENCHING 447771 WESTFIELD'S
ON -SITE TENANT COORDINATORS BEFORE PRECEDING WORK.
TENANTS CONTRACTOR SHALL PROVIDE A FIRE WATCH AND
PORTABLE FIRE EX77NGUISHER WHERE EVERY WELDING IS DONE
WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE
FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT
LEAST 1 HOUR AFTER THE COMPLETION OF ANY WELDING. THIS
SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA.
HANGERS
INSTALLED
EACH SIDE
OF EXP. TANK
FOR SUPPORT
AMTROL ST -5
THERMAL
EXPANSION
ABSORBER
VACUUM TYPE
RELIEF VALVE'`
CW
SCALE O = 1 - O "
3/4"
HW
3/4"
GATE VALVE (TYP.)
3/4" RUN FULL
SIZE TO MOP
SINK.
UNION (TYP).
DRAIN VALVE.
PLATFORM OR SHELF
BY GEN. CONTR r
\\ \\
SET INTERNAL ADJUSTABLE
THERMOSTAT (LOCATED
BEHIND COVER) TO -110' F
OUTPUT.
WATER HEATER DETAIL
WCO
MB
PLUMBING PLAN
SCALE 1/4" = 1' -0"
SCALE N.T.S.
LA V
I
0
GAL V. DRIP PAN.
SEPARATE 3/4"
COPPER PIPES
DRAIN TO MOP
SINK.
TO EXIST. SAN STUB
FIELD VERIFY EXACT
LOCATION OF FLOW
1 /2'HW
WATER RISER DIAGRAM
INSULATE ALL PIPING
IN ACCORDANCE 1447H
SPECIFICATIONS
3/ 4" T&P R
EUEF VALVE:
WATER HEATER. SEE
EQUIPMENT SPEC.
- 2" WIDE, 20 GA. SHEET
METAL BAND, SECURE
TO WALL FOR SEISMIC
BRACING WHERE REQ'D
BY CODE
1 /2"CW TO FLOOR
DRAIN TRAP
2 "V I
LL INCOMING
3/4" C.W.
2 "V
2 "V / 2 "VI
SANITARY RISER DIAGRAM
VENT TO ROOF
NOq- ILE 9
3 "
VTR
3 "
REVIEWED FOR
CODE COMPLIANCE
APP ENE
NOV Z 4 21109
EXTEND 4" S.S.
TO EXIS77NG
5..5. V.I.F.
City of Tukwila
BUILDING DIVISt l l
RECEIVED
NOV 1 8 2009
PERMIT CENTER
DMC STORE #
4083
RELOCATION
ARCHITECT OF RECORD:
G O R T L A N D CWIA
M 0 R G A N
ARCHITECT
711 NORTH FIELDER ROAD
ARLINGTON, TEXAS 76012
PH: (817) 635 -5696
FAX: (817) 635 -5699
co
O_
U
w
0
z
kk
w
M
✓
W
Q � �
I lin ini C W Z H z = U zic
O i_
CA O F_.
E ffignaMei In CO
0
0 a
E
DRAWN BY: C.M.
MECHANICAL
SPEC.'S & DETAILS
MP1.1