Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D09-012 - SUBWAY - TENANT IMPROVEMENT
SUBWAY 3725 S 144 ST D09 -012 Parcel No.: 0040000115 Address: 3725 S 144 ST TUKW Suite No: Tenant: Name: SUBWAY Address: 3725 S 144 ST , TUKWILA WA Owner: Name: SILVERDALE- TUKWILA LLC ET A Address: 9777 WILSHIRE BLVD #1009 , BEVERELY HILLS CA 90212 Phone: Contact Person: Name: ANDRE MROZ Address: 12745 39 AV NE , SEATTLE WA 98124 Phone: 206 669 -9763 Contractor: Name: TAMARAC CONSTRUCTION Address: 12745 39 AV NE , SEATTLE WA 98125 Phone: 206 669 -9753 Contractor License No: TAMARC *991KB Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 City*f Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us $43,750.00 DEVELOPMENT PERMIT Permit Number: D09 -012 Issue Date: 03/16/2009 Permit Expires On: 09/12/2009 * * continued on next page ** Expiration Date: 05/03/2009 DESCRIPTION OF WORK: TENANT IMPROVEMENT: CONSTRUCT FRAMING, INSTALL ERP, AND INSTALL SUBWAY DECOR Fees Collected: $1,368.39 International Building Code Edition: 2006 Occupancy per IBC: D09 -012 Printed: 03 -16 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City o*Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: DO9 -012 Issue Date: 03/16/2009 Permit Expires On: 09/12/2009 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: () � I hereby certify that I have read and ned t 's permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie •, , whether specified herein or not. The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t -- erformgce of wgrk. I am authorized to sign and obtain this development permit. Signatu Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 Atze X4.( Date: - l6�pD9 D09 -012 Printed: 03 -16 -2009 Parcel No.: 0040000115 Address: 3725 S 144 ST TUKW Suite No: Tenant: SUBWAY 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D09 -012 Status: ISSUED Applied Date: 02/02/2009 Issue Date: 03/16/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All food preparation establishments must have Seattle/King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle /King County Department of Public Health, (206/296- 4928), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the doc: Cond -10/06 D09 -012 Printed: 03 -16 -2009 following concerns: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 15: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75 or less. (IFC 906.3) (NFPA 10, 3 -2.1) 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 17: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 19: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: Gates serving the means of egress system shall comply with the requirements of the International Fire Code. Gates used as a component in a means of egress shall conform to the applicable requirements for doors. (IFC 1008.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Each door in a means of egress from an occupancy of Group A or E having an occupant load of 50 or more and any Group H occupancy shall not be provided with latch or lock unless it is panic hardware or fire exit panic hardware on rated fire doors. (IFC 1008.1.9) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 25: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 26: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not doc: Cond -10 /06 D09 -012 Printed: 03 -16 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 27: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 28: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 29: Every room or space that is an assembly occupancy shall have the occupancy load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (IFC 1004.3) 30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 31: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4)(Including adding sprinlder heads to the walk -in cooler /freezer.) 32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 33: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 34: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 35: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 36: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 37: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 39: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 40: In occupancies of Groups A, E, I and R -1 and dormitories in Group R -2, curtains, draperies, hangings and other decorative materials suspended from walls or ceilings shall be flame resistant in accordance with NFPA 701 or be noncombustible. Where required to be flame resistant, decorative materials shall be tested by an approved agency and pass Test 1, as described in NFPA 701, or such materials shall be noncombustible. Reports of test results shall be doc: Cond -10/06 D09 -012 Printed: 03 -16 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • prepared in accordance with NFPA 701 and furnished to the fire code official upon request. (IFC 805.1, 805.2) 41: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes such condition or violation. 42: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila (206)575 -4407. * * continued on next page ** doc: Cond -10/06 D09 -012 does not imply approval of Fire Prevention Bureau at Printed: 03 -16 -2009 Signatur Print Name: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulatPng construction or the performance of work. Date: 3 — / — a "/ D09 -012 Printed: 03 -16 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwweituktvila.wa.us '1url� btng /was, } P ermit 'tzblc W orks Permit Building Permit No. Mechanical Permit Proj (For'''ofce -use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 372 SO /Tf/ TRC6T Tenant Name: rj(/ 4 //9'/ Property Owners Name: Mailing Address: 37.2.5 5 Ai flrif 5TQET CONTACT PERSON: - who do ,we'contact wh "en,your, permit is ready to"be issued Name: 7 CONS ' »N th/2c I IWZ Day Telephone: Zt26 66 9 976 3 Mailing Address: 127453+114 vc. NR sk -G ?ear C./kk/ /L!9 City City State E -Mail Address: :0-Z51 A OL . €o M Fax Number: GENERAL CONTRACTOR INFORMA =� (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5 Company Name: T H Opt dOt $TTRMc-1 / on/ Mailing Address: 12745 311' i Ave NE *E',477Z Contact Person: AN IVC 11 AveZ E -Mail Address: ��E/ 0. /� Iz • 9D/;r Contractor Registration Number: T A /1AR C '* 9.c 1 K 8 ARCHITECT" OF RECORD All plans must be wet stamped by Architect of Record King Co Assessor's Tax No.: one,/ QQQQ /1 S Suite Number: Floor: New Tenant: $l Yes ..No 41/4 9(7 1f1; State Zip Zip Wi °, //ZS City State Zip Day Telephone: #206 tD t q 9713 Fax Number: Expiration Date: c25 7 -2.010 9 Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State State Zip ENGINEER OF RECORD _ "All plans must be,wet stamped by Engineer Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Zip Page 1 of 6 BUILDING PERMIT INFORMATION --;-206-431-3670 Valuation of Project (contractor's bid price): $ 4 13.7 5 . t Existing Building Valuation: $ Scope of Work (please provide detailed information): T. I. I N4TAL L $[.t Je3 LJi. r _ Ff2. LwtG- I NSTA,u . F.0 p, 1 HT2/42,L 5 t-1 J3Wi4 Y bee.tlR. Will there be new rack storage? ❑ Yes •.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 1S Floor 2 Floor 3`a Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deok 12-10F Interior Remodel 12/OF Addition to Existing Structure lvl� NO Type of Coastruction per IBC Type of Occupancy per IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safely ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: 1Applications\Forms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty '' Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:Wpplications\Porms- Applications On-Line \2009 Applications \I -2009 Permit Application.doc Revised: 1 -2009 bh PLUMBING AND GAS PIPING PERMIT INFORMATION + - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: State Zip Page 5 of 6 Signatur Date Application Accepted: in 1 PERMIT APPLICATION NOTES — Applicable to all permits his application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Print Name: ' ' 0- /7•20z.,_____ Day Telephone: 206 66 9 -976 Mailing Address: 12745 YWII oz- i D2- H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1.2009 bh Date Application Expires: 0 Date: 2 2 �O s$,t y lc/ City State Zip Staff Initials: Page 6 of 6 Parcel No.: 0040000115 Address: 3725 S 144 ST TUKW Suite No: Applicant: SUBWAY Receipt No.: Initials: User ID: R09 -00414 JEM 1165 Payee: TAMARAC CONSTRUCTION ACCOUNT ITEM LIST: Description doc: Receipt -06 BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2979 831.10 Account Code Current Pmts 000/322.100 640.237.114 RECEIPT Permit Number: D09 - 012 Status: APPROVED Applied Date: 02/02/2009 Issue Date: Payment Amount: $831.10 Payment Date: 03/16/2009 12:54 PM Balance: $0.00 826.60 4.50 Total: $831.10 PAYME REC Printed: 03 -16 -2009 Parcel No.: 0040000115 Address: 3725 S 144 ST TUICW Suite No: Applicant: SUBWAY Receipt No.: R09 -00163 Payee: TAMAR.AC CONSTRUCTION ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Initials: JEM Payment Date: 02/02/2009 01:10 PM User ID: 1165 Balance: $831.10 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2946 537.29 Account Code Current Pmts 000/345.830 537.29 Total: $537.29 Permit Number: D09 -012 Status: PENDING Applied Date: 02/02/2009 Issue Date: Payment Amount: $537.29 doc: Receiot -06 Printed: 02 -02 -2009 COMMENTS: 9 4.A-4 i"� 0�.. q �, r i t'e- k A S S; A 9.--A J W Y -„ N1 eJ / e,/N c, L 1 f , — 4 AO b-e e. 1 J C ; ,, e I. , I l cb A �z�l' u L` r L-0 / i : d o7 Ate/ JP' f(j1V3a $ 1 r- e (r_ 1 T S & » (l, ;-,,/1 . 'r hk� t (..:; . ^. A f P49 Pc r PI, Requester: / //')/ ' P c- \ M id Phone No: .te n/ 4 T C.,,6 [ P 1a Project: J Type of In cti : r' �t e U • / Address: 3 r7ZS 5,,4-‘114 l 44 r Date Called: Special Instructions: Date Wanted: a m — .eig p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit PERMIT NO. / CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 INSPECTION NO. Approved per applicable codes. Corrections required prior to approval. ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMEENTSS g M I y . � 1 Fk(e4 ( 0 k.;.n► 1 1 -- D t Auk_ ( -.P (( ti Type of. Ins oe. pA " -e.0' A- ppf`'JE D n) { Date Called: ( Fli 0 5; i n A la a at 9 A T ek or ',JAI Tf\oe /PA i ( ( O ,)vA.. 4r2 J 4 (L Lceet Requester: 1,J Imo, I -e o«. J a'.e - - 0 A e el i e`g • b-' G "h e c •e1-',_ 1 T` o f Y i t-Q S 06/ f . INPeel eit^9. L. 1. ,� p. C Jr:)(3rJ 1.407,r &D a+ e /ID iii4,',i ire Pro ec Type of. Ins Address: � Date Called: Special Instructions: p343 r� QA F_ ` 1 — d ( Date Wanted: l..0 ■ i o a.m. `j - orff. Requester: Phone No z — GIG/ _ 7(3 -i=t= INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3470 Approved per applicable codes. Inspector[: Corrections required prior to approval. e(�? Date: 1 C 0 Q LI $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee•n ust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: boy - ore 11 COM MENTS: Type of r ( �t `gyp .() j1..fr-4' (: ,.-- 1--‘ -A e -Q1 Date Ca �" ,... A_ ,L. S7 (i? iutJ AT(1-\ vac ,i).-J 1 Date Wanted: 4 ` if i� 1 en 7 A (, C , 9, 1 2,.6.4 sr-,\ k_4( ` Phone 1 (do q - 17 "-3 -,f g- J-^ 1/•1 i s A pp rU J O Jr . G /vtcr /∎ i( .1C . .`r-.• 0 rA 6" (-0 p 5 . Alert /0 ' -ti-I° I- - L, G i) r- 0. . (,� , . — A t i A ` / r. ,9 .it-/ i A 1 d Project'. J ` C/' Type of r ( �t `gyp Address: 44 3'?2S S am t Date Ca �" ,... A_ ,L. S7 Special Ins � Y �'7 ? i , / .4. c) f / Date Wanted: 4 ` if i� 1 en Requester: Phone 1 (do q - 17 "-3 -0 1 -- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Inspect r: Doi - oi2l (206)431 -36x0 Corrections required prior to approval. 7 (Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: Type of Inspection: F 1) ' N L Address: Date Called: i 6.0A. We- J r p 1.' c' Phone No: Ni AI /), /1 A ' 6 -r r" � As we . / * c. I Pl A.,4..1 1 f { * u /L � 4 1 7 P 1 - . k 1 Projec zt bw Type of Inspection: F 1) ' N L Address: Date Called: Special Instructions: Date Wanted: 3- 2 7- Os Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION iZ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Inspector: Corrections required prior to approval. Date: 3_ 27 . 4j y ri $60.00 REINSPECTION FEEBEQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter BLit., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: ..lig Sprinklers: Y Type of Inspection: Efrr 16N {Aie ed Address: 312C Suite #: . ) J ( fir-. Contact Person: 6.601 M4 { � � ) -- Special Instructions: Pre - Fire: Phone No.: • Needs Shift Inspection: 1 Sprinklers: Y Fire Alarm: 1/ Hood & Duct: A/ _ Monitor: Pre - Fire: . Permits: Occupancy Type: 73 ( , < 5-o Ica ) Asa COMMENTS: /Ni'F. )1e— _ ZAN, - O t -- 27'4 Wafkf3 oN &EWERA k ;nspector: ut/a!,/.ei /512-- Date:. -- _ -- : / Hrs.: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER CIT . . OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Word/Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS Corrections required prior . to approval. n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 February 23, 2008 Andre Mroz 23856 39 Ave NE Seattle, WA 98125 RE: CORRECTION LETTER #1 Development Permit Application Number D09 -012 Subway — 3725 S 144 St Dear Mr. Mroz: This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. I have also enclosed a Non - Residential Sewer Use Certification that must be completed prior to issuance of the permit. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, ie rshall errhit Technician eticl J File o. 009 - 012 • C ity of Tuk, , i;' %' Jim Haggerton, Mayor P:\Perrnit Center\Correction Letters\2009009 -012 Correction Letter #1.DOC wer • Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Building Division Review Memo Date: February 17, 2009 Project Name: Subway Permit #: D09 -012 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The original plans provided show a number of inconsistencies that shall require clarification and design alterations. Sheet # (3) floor plan and details are inconsistent with the Subway plan sheet numbered (1 of 2). Please provide revised architectural drawings that clearly identify the demo of the existing construction and show the new revised floor plan to be consistent with the proposed Subway floor plan. Include wall construction details and specifications that are consistent with the Subway floor plan. Identify those areas that are open ceilings and any areas that shall have suspended ceilings or hard lids. Provide details for the construction of those ceiling areas. 2. This tenant space shall require two means of egress. It is the understanding the gate is to provide security during Subways off hours. The second means of egress from the Subway space shall be through the existing grocery store during Subways hours of operation. Therefore a note shall be placed at the rolling gate "THIS DOOR TO REMAIN OPEN DURING SUBWAYS HOURS OF OPERATION ". (IBC 1008.1.8.3 # 2.2) 3. In addition to item # 2), on the plan cover sheet provide documentation to indicate the subway shall be open only during the hours of the grocery store operation. 4. Provide 4 sets of all plan sheets complete with the new revised sheets. All plan sheets shall be the same size sheets. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. February 3, 2009 Andre Mroz 12745 39 Ave NE Seattle, WA 98125 RE: Letter of Incomplete Application # 1 Development Permit Application D09 -012 Subway — 3725 S 144 St Dear Mr. Mroz, This letter is to inform you flat your permit application received at the City of Tukwila Permit Center on February 2, 2009 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department need to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the following comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, J n er Mar all t Technician En e : res File: D09 -012 • Cizy of Tukwila Department of Community Development Jack Pace, Director P:\Permit Center\Incomplete Letters\2009\D09 -012 Incomplete Ltr #1.DOC wer Jim Haggerton, Mayor 6300 Southcenter Boulevard. Suite #100 o Tukwila_ Wa.chinmrnn QR1RR • Phnno• 9(M- 4ql -VA7a ® P.v• 9/1R_421_2AAC i • • Determination of Completeness Memo Date: February 3, 2009 Project Name: Subway Permit #: D09 -012 Plan Review: Aller.. Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiners 1 The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). ( If a pp lic able) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide a reflective ceiling plan. Plan shall identify lighting, exit signs and emergency lighting. (IBC Section 1006) 2. Please provide specifications with details that meet ASCE standards for the new suspended ceiling. Identify type of perimeter supporting enclosure angle (typically 2 "). (ASCE Standards 9.6.2.6.2.2.) 3. Provide a building floor plan. Floor plan shall clearly identify the location and number of bathrooms. Bathrooms and access to them shall meet accessibility code requirements. Include dimensions. (2003 ANSI) 4. Provide a completed Nonresidential Energy code compliance form. (Lighting Summary form) 5. Application with Seattle/King County Department of Public Health shall be required and provided with the permit application. Should there be questions concerning the above requirements, contact the Building Division at 206 -431 -3670. No further comments at this time. ACTIVITY NUMBER: D09 -012 PROJECT NAME: SUBWAY SITE ADDRESS: 3725 S 144 ST Original Plan Submittal X Response to Correction Letter # 1 _ DATE: 03 -11 -09 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: ` wilding Division � ' Public Works ❑ Complete TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28-02 APPROVALS OR CORRECTIONS: Fire Prevention Structural Structural Review Required DETERMINATION O COMPLETENESS: (Tues., Thurs.) • ING SLIP Planning Division Permit Coordinator DUE DATE: 03-12-09 Incomplete l l Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: U No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 04 -09 -09 Approved Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 1_i ACTIVITY NUMBER: D09 -012 DATE: 02 -11 -09 PROJECT NAME: SUBWAY SITE ADDRESS: 3725 S 144 ST Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # After Permit Issued DEPARTM N S: eif 2,11,01 Bu di g Di i 64-V N A- Public Works Complete Comments: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 OPERANT COORD COPY • PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Planning Division Permit Coordinator Incomplete n Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO TING: Please Route Structural Review Required U No further Review Required n REVIEWER'S INITIALS: DATE: Approved with Conditions Not Approved (attach comments) DATE: n DUE DATE: 02-12-09 DUE DATE: 03-12-09 Permit Center Use Only ^ CORRECTION LETTER MAILED: D� ti1 Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: /a.�' ACTIVITY NUMBER: D09 -012 DATE: 02 -02 -09 PROJECT NAME: SUBWAY SITE ADDRESS: 3725 S 144 ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENT : Bui ng i Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 *PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 4 Fire Prevention Structural Incomplete x -5 -0 1 911 ii0 02. Planning (vision Permit Center Use Only INCOMPLETE LETTER MAILED: O 0 101 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required n REVIEWER'S INITIALS: ❑ Permit Coordinator DUE DATE: 02 -03-09 Not Applicable ❑ No further Review Required DATE: Approved Approved with Conditions 1 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: u DUE DATE: 03-03-09 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Date: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206431 -3665 Web site: http: //www.ci.tukwila.wa.us Sheet Number(s): "Cloud" or highlight all areas of revision including date of rev Received at the City of Tukwila Permit Center by: Entered in Permits Plus on. 4 1" ''09 \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: SIJ MI Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: 009 - O \ ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: t Project Address: 3 - 72S S , �\I� - N S Contact Person: OANAxt L AMA sX Phone Number: U a06, — cQG 9- 9'7( Summary Revision: c� R n o c i a to > .A�1,o o Q R�� AQ CYIX c3�Q i :A .51% mil.'_ \ - • �__ , ■ ! % 6.,1 )1, . :�.: . 1 • • (ICY OF ?t1KWRA MAR 112009 Date: 2_ ..,2J('©4 Project Name: Project Address: City of Tukwila \applications \forms- applications on line\re vision submittal Created: 8 -13 -2004 Revised: • • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Subway 3725 S 144 St Received at the City of Tukwila Permit Center by; Entered in Permits Plus on 112 Plan Check/Permit Number: D09 -012 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner C►* p O �� FEB 1 01009 PERMIT CENTER Contact Person: /4NME tikoz Phone Number: 6 ?76 3 Summary of Revision: 1)1h8 b6+ hi iS going -D be ins lm AibQV$ The extevi and ull olher al veal i 1 �xiM '.d4 lo&i*ion .1E. NO susi.tondeou I 1, ill 0 , u 1,� , it It . 0 t. t .� alt -& Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 CBIC INRSD0214 05/02/2006 05/02/2009 $1,000,000.00 03/14/2008 4 CBIC INRSD0214 05/02/2005 05/02/2006 $1,000,000.00 05/27/2005 3 CBIC INRSD0214 05/02/2004 05/02/2005 $1,000,000.00 04/22/2004 2 CBIC INRSD0214 04/24/2003 05/02/2004 $10,000,000.00 04/28/2003 1 CBIC INSSD0214 05/02/2001 05/02/200310/07 /2002 $1,000,000.00 05/02/2001 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 CBIC SD0214 05/02/2002 Until Cancelled $12,000.00 05/03/2002 1 CBIC SD0214 05/02/2001 05/02/2002 $6,000.00 05/02/2001 Name Role Effective Date Expiration Date MROZ, ANDRZEJ OWNER 05/02/2001 Untitled Page General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company TAMARAC CONSTRUCTION 2063627917 12745 39TH AVE NE SEATTLE WA 98125 KING Individual UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602117770 ACTIVE TAMARC`991 KB CONSTRUCTION CONTRACTOR 5/2/2001 5/27/2009 TAMARC`099DH GENERAL UNUSED Business Owner Information Bond Information Insurance Information • https:// fortress .wa.gov /lni/bbip/Detail.aspx ?License= TAMARC *991 KB • Page 1 of 1 03/16/2009 INTERIOR DIMENSIONS: DESIGNED BY: PATRICK ROSE POLYCARBONATE qqq EXISTING 1/2" RECOMMENDED VOLUME SODA 3/4" MACH FOR HIGH USE AREA'S / / 1 2" N N 3/4 HAND SINK 3/4" 3-COMP. SINK / -3/4» JANITO ICE MACH. 3/4" /4" 1 2" 1 2 " J r / 1 1 I �= E WATER HEATER 1/2" » / W.C. TPR TO OUTgIDE C / \ N SECOND RESTROOM IF LOCAL 1� CODES REQUIRES INSTALATION. LAV. C. ' / / OVEN - 15 "H X 26 1/4"W X 20 1 /4 "D / PROOFER - 33 1/2 "H X 26 1/4 "W X 20 1/4 "D 33 3 8" DOOR SWING; / 36 7 1/2" [19.1cm] '_' [91.7cm] / [84.7cm] / OVEN - 34 3/8" y , r _, E » 28 5/8 PROOFER - 29 1/2" 8 ° °o ° °o ° ° ° ° ° ° ° 00000°° ° °00000 • o o ° o ° ° ° • 0 0 0 0 0 0 0 o 0 0 0 0 0 �, ° 0 0 0 0 0 0 ° ° ° ° ° ° ° • ° ° ° ° ° ° ° 00 = 7,16 20 3/4" 2 8 " 36 1/2" 3 1/2" [8.9cm] [72.8cm] VEN [52.7cm] [71.1cm] �., GLASS 1/2 27 1 /8 POLYCARBONATE [92.7cm] [20.3cm] FUSE cm] [68.8cm] GLASS A I 25" [63.6cm]' ELECTRICAL INLET \ II-E-1 v [wol'6LL] y G - _ - „Z/ L OL 1 „g /c LS 1 MINIMUM WATER CONNECTION IS 30 psi. 0000 PLAN VIEW *1/4" WATERLINE IS REQUIRED PRESSURE SPECIFICATIONS _ o o • 000000 000000 000000 000000 000000 000000 � 1/ 4" WATER INLET MODEL: SUB -123P FOR PROOFER. FOR THE 1/4" WATER SPECIFICATIONS I 0 0 [woL i � I I HOT & COLD WATER SYSTEM _ _ - - - - - - / N N 1 1/2 1 1 / 2 "� SOFT ORI .. 2" 4 ' EXISTING 1 1/2" 3 -COMP. SINK N HAND' SINK / / I/ / / MACH 2" 2 ` I 1 1/2" 1 N / J I j SIN NITOC • 3" 3" VTR I / 1 I / SLAV. 2 c / I \ \ .c . 3" NOTE: THE PLUMBING REPRESENT A ND ARE CODE REQUIREMENTS. "WATER SECOND RESTROOM IF LOCAL CODES REQUIRES INSTALATION. i AV.N 1 �/ - / ISOMETRICS SHOWN A TYPICAL "SUBWAY" STORE, SUBJECT TO ALL LOCAL ' SYSTEM IS TO BE PRESSURIZED" _ r , I ; • WATER E ,�� o FILTER FOR AUTOMIST® r , "or) E o ELECTRICAL ® • I 0 Q O I i I _ I VOLTAGE PHASE AMPS KILOWATTS NO. WIRES SHIP WT. V \II FRONT SIDE BACK \ O 120/208 1 30 5.135 4 570 LBS. 22 7/8" 29 3/8" A I I - 2 120/240 1 27 5.135 4 570 LBS. 0 ,-6 \ MODEL: HW FONTHILL PEAR 120/208 3 20 5.135 5 570 LBS. [58.1cm] [74.6cm] LAMINATE MODEL: CA57 -RR1 ALUMINUM CONSTRUCTION. POLYCARBONATE DOOR AND SIDE AND BACK WINDOWS. FONTHILL PEAR LAMINATE ON SIDES AND BACK. \ il 120/240 3 17 5.135 5 570 LBS. WATTAGE: 1200 REQUIRED PER LOCAL CODE FROM FACTORY TO BE HARDWIRED ON SITE. HAS ETL CUS & NSF LISTINGS. o o NSF APPROVED OVEN 4000 - P ROOFER: ��) ,�� SIDE o FRONT \ REAR FIELD WIRING UNIT IS SHIPPED THE SUB -123P NU -VU SUB -123P DIGITAL BREAD OVEN /PROOFER NU -VU BREAD CABINET LOCKWOOD FRONTLINE BREAD DISPLAY CABINET » ,48 �� 48 R� » » 24 ,36 » » ,60 ,72 » » » » » 24 ,36 ,48 ,60 ,72 cm] [15: [61cm "' 152.4cm,182.9cm] "_M " '1.9cm, [61cm,91.4cm,121.9cm, 152.4cm,182.9cm] �"!!! - .■.11.■■ ! „17/ L - 171. ' [w oz•gC ] [ 1 29 1/2" [wo6• -17L] [w06'-17L] • 29 1/2" 1 , 29 1/2" \ L [w 2 3/4" DIA. „(,/ I. oc, \ L [w °6 f 7/ I C7 CUT -OUT IN TOP FOR DROP -IN SODA MACHINE (MADE BY MFR.) REFER TO MFR. OF SODA MACH. FOR EXACT DIMS. 2 3/4 DIA. 1 �!�!�_ DRAINAGE & VENT SYSTEM 111 11 �II 1 . � : 26" I, ,. E 23" E i „LuoC *OZ � � , S ` z E N i j CY <2-4 r -, 1- E `� a \ vv r' to [woLTC] „ii/ L I,1OZZ -2i d IVHS IM t I '-. s PLAN VIEW PLAN VIEW P N IEW i \ PLAN VIEW AT \ OPTIONAL: PLAN VIEW 13 1 /2" 15 5/16' „i7 /£ 6Z [75.5cm] 27 1/2" V [ z\ a r7 ii, / / [38.9cm] PLASTICS, INC. N TOP OF ACRYLIC 4 REMOVABLE SHELVES \ \ E . 6 [w o0•Lg] , 1,[w017•g] [w . 91./13 17Z `� r E v N o \ COMPRESSOR LOCATION d- ,- E (N! o �, r, E OPTIONAL RIGHT HAND SINK SHOWN ALSO AVAILABLE) ALSO AVAILABLE ANGLE. CUT -OUT IN TOP FOR MAY BE ON RIGHT ALSO AVAILABLE [90.2cm] DEPTH. [34.3cm] MANUFACTURER: �- m ` N (LEFT HAND SINK d HAND SINK IS 90 DEGREE DROP A OR TO HOLD AVAILABLE. SIDES -S -IN SODA LEFT SIDE IN 35 1/2" COMPRESSOR LOCATION AMANA RFS12SW2 / 21 5/8" [54.9cm] \ AMANA RFS12SW2 19 13/16" [50.3cm] ADVANCED DISPLAYS IN COOKIE P /NAPKIN RISER MADE OF 1/4" THICK CLEAR COOKIE DISPLAY CASE HAS 1 \ .� 2 3/4" DIA. -r I\ i: 1 „g2 \ I. [woi7 - - I , I � I � [w oi7.1.6] 1 „92 \ [ " 1.6] / r -1 r - -- -- _ I - 1 IL_ - -� I r - 1 L r -1 -1 SHARP R -22GT SHARP R -22GT 20 1/8" [51.1cm] 18 1/2" [47.0cm] AMANA RFS12SW2 SHARP R -22GT L J L J L _ _ _ _ J L _ _ _ _ J \/ \ X / / \ / \\ _ _ _A J L J COOKIE DISPLAY CASE 19 13/16" ELECTRICAL COOKING POWER REQUIRED: C; PLUG TYPE: POWER CORD: FREQUENCY: SAFETY STANDARDS: NSF, UL, CHARACTERISTICS: ELECTRICAL CHARACTERISTICS: POWER: 1200 WATTS COOKING POWER: 1200 WATTS 120 VOLT POWER REQUIRED: 120 VOLT ` PLAN VIEW N N, N [50.3cm] PLAN VIEW �.n [wog•5] N [w o17'29 - - 14 316 DEEP [36.Ocm] 1 r I I e U I l '•' - ' I I I I I HERTZ _ • 60 HERTZ 2000 c �,� N N „2Z \ _. T- „6L 1 [wo-r85] I I ® .ie [wo£ ] ataxy ELEVATION RIGHT END ELEVATION ON DOORS STEEL TOP. UL -S LISTS[ RIGHT END ELEVATION COUNTER WITH STAINLESS LISTED RIGHT END 200AMPSTTS / 5 -20 PLUG TYPE: 5 -20 5' (1.5M) POWER CORD: 5' (1.5M) 2450 MHz FREQUENCY: 2450 MHz SAFETY STANDARDS: CSA UP, FCC, DHHS, NSF T i § § § §§ 0000 _ r r, n� wcg•gg] FONT HILL PEAR LAMINATE ON DOORS AND SIDES WITH STAINLESS STEEL TOP. UL, C -UL AND UL -S LISTED ELECTRICAL SPECIFICATIONS #5 -15) FONT HILL PEAR LAMINATE WITH STAINLESS UL, C -UL AND ELECTRICAL SPECIFICATIONS AND SIDES #5 -15) OPTIONAL REINFORCED TOP TOP STEEL TOP. \ MODEL: FOR USE WITH DUKE ALUMINUM WELDED HOLDS 12 HALF NSF RC- 121318 REFRIGERATED BACK COUNTER CONSTRUCTION SIZE PANS (13" X 18 ") APPROVED R ' MOUNTED SODA MACHINE FONT HILL PEAR LAMINATE ON DOORS AND UL, C -UL AND UL U ' ° 4 r " N I I " • • 120/60/1, 3.8 AMPS. 6' CORD & PLUG (NEMA 120/60/1, 6 AMPS. 6' CORD & PLUG (NEMA ' i \ > d' \ r-, g ELEVATION , ELEVATION 48" DUKE REFRIGERATED BACK BAR 60" DUKE REFRIGERATED BACK BAR DUKE BACK COUNTER MICROWAVE OVEN . DUKE RETARDER CABINET N O 25" 60" 60" 61" 38" 1" RECEIVED � CITY 1 ®F'I'U1eYri� FEB 0 2 2009 ERMIT CEN TER 83.5cm HOT FOOD UNIT 152.4cm LAID PAN UNIT 152.4cm COD PAN UNIT 154.9cm FlNIC IONMJTY CASH UNIT ® � (61" 00 (4) SAN JAMAR E -Z FIT CUP DISPENSERS IN TOP AND 73" CASH UNITS ONLY: 49" AND DSPENSERS COUNTER ON EMPLOYEE SIDE) ,_ N d Q „ 60 3/32 2.25" HIGH E ON BACK AND HINGED BACK SPLASH BOTH ENDS DOORS 96.5cm 27 5/16" CD C=7 o ` o - r r o o ; �i - •a ' j ) [ I I USwP I E d / O N U7 (Ni Q m / N [69.4cm] 2.5cm tt r-o �-I [152.6cm] I 2 H' G I I- J 01 Lwo' L Zo] , (0 J „ gZ 1 [ u Dwo LL ] L , - N) „8C v u7 0 CO v - , _ \ -o- 12 X 12 TOP \ CUTOUT 5 WIDE CD DRIP TROUGH 1 LEFT END • • I • O O • I • C1 1i1� LEFT END POLY CARVING BOARD � (2) CUTOUTS IN PatBOARD POLY CARVING BOAR r) CUTOUTS STAINLESS e• DEEP COVER IN PaYBOARD ,�^ 16 `� TORONADO 2 MICROWAVE /CONVECTION OVEN 402S VERSION 3 MICROWAVE /CONVECTION OVEN � � STAINLESS STEEL 1/3 SIZE e' DEEP F000 PANS 60" LIFT UP DAY COVER PLAN VIEW �,PPUED STET]. 1/3 SZE FOOD PANS N N ` 0 o O (0 6 m u r 40.6cm] / - I ' I TT F Fi - FIXED 25" FIXED 60" LIFT UP DAY 6 DIA. TRASH HOLE _ ' E N In LEGS L 1 # #14 GA. PAINTED RIGHT E N D MULTI -SPEED CONVECTION BLOWER WITH CONTROLLED BOTTOM BROWNING ELEMENT. STAINLESS STEEL FRONT, TOP, AND BACK. ARE BLACK POWDER COATED. ELECTRICAL: INDEPENDENTLY SIDES PANELS -F WATTS) 3500 WATTS) MICROWAVE ACCELERATED HIGH MULTI -SPEED IMPINGED HOT AIR OVEN. STAINLESS STEEL FRONT, TOP, SIDES AND BACK. ELECTRICAL: DAY FLUORESCENT LIGHTING FLUORESCENT LIGHTING \- ABOVE COLD PANS ABOVE COLD PANS ^ � � STEEL KICKPLATES w ADJUSTABLE FEET 5/8 DIA. X 6 HIGH GALV. ELEVATION -� i s N .- N E .- M N i7 ��� �� E _ - ' \\ ii N\ / \ // c \ \\ / \ /� o �� \ i�z . u7 " c 4 � In `-' ' op M 14" X 17" ELEVATED POS /T OUCH PAD SHELF ' - r N ` ? r' . DESTINATION CENTER 208/240 VAC, 60 HZ, 1 PH. (220V, 60HZ, & 50HZ AVAILABLE) NAMEPLATE RATING 30 AMP , PLUG /CORD: NEMA 6-30P/611.8M], SJTOW MAX INPUT: 6250 WATTS ' MICROWAVE OUTPUT: 1500 WATTS CERTIFICATIONS: NSF, CSA, FCC 208/240 VAC, 60 HZ, 1 PH. (220V AVAILABLE) NAMEPLATE RATING 30 AMP PLUG /CORD: NEMA 6- 30P/5r1.5M], HO7RN (220V: IEC 309, 3 -PIN, 32 AMP) MAX INPUT: 5990/6675 WATTS (220V: 6700 MICROWAVE INPUT: 3500 WATTS )220V: CERTIFICATIONS: UL, cUL, NSF, FDA, FCC u __ SUB- BEVDEST -6OL SHOWN ABOVE . AVAILABLE IN THE FOLLOWING LENGTHS: 48 3/32 E l222cm , 60 3/32" [152.6cm], 72 3/32" 183.1 cm 84 1 /8" [213.7cm]. , FINISH: H LL FONT HILL PEAR LAMINATE SIDES AND DOORS WITH STAINLESS STEEL TOP. UP, C -UP AND UP -S LISTED. �_ \Y </ j s /✓ ' . lo r7 , U • L__ �"' �! ((' L"' ��� ,_, E c \ n M Iri m u - u7 - PLAN VIEW - - L FUNCTI SHELVING G FUNCTIONALITY SHELVING - -- = LEAR FOR SAFE 21 1 /8 " ( ' ' . r� ro .0 - 0 • CORD & PLUG ( NEMA /6-16) e ' - 0' CORD kPLUG (NEW 0-16) A - 1e' �' II" � mo ' [53 .7cm] ^ DUKE BEVERAGE TURBOCHEF RAPID COOK OVEN MERRYCHEF RAPID COOK OVEN �' -- i u i i = i -IM i i i III THERMOSTATIC HOT FOOD WELL CONTROL W/ OMNI LIGHT LOCATION FIELD SHIPPED LOCATION OF ONE (1) 5 -15 120V SINGLE OUTLET. COMPRESSOR COMPARTMENT OF OPTIONAL W/REMOVABLE S.S. INSTALLED OUTLET. HOUSING A 1/3 W/ BLANK COVER CONDENSING UNIT RIL HP (120 OCATION OF OPTIONAL FIELD INSTALLED OUTLET. LOCATION OF OPI11ONAL SHIPPED W BLANK COVER FIELD INSTA D OUTLET / SHIPPED W/BLANK COVER LOCATION OF ONE (1) COMPRESSOR COMPARTMENT 5 -15 120V SINGLE OUTLET. W REMOVABLE S.S. RI HOUSING A 1/3 HP (120V) EMPLOYEE SIDE CONDENSING UNIT ((2) 5 -15 OUTLETS FOR EXPANSION 120V UPLEX AND (2� BLANK CASH UNIT END VIEW OUTLET UNDERNEATH OUTLET UNDERNEATH ULTRA SLIMLITE 21 " [53.3cm] STANDARD 4" WIDE PURSE RAIL W ITH LIGHTS AND BIRNBAUM FINISH \ MANUFACTURER: TRANSLITE SONOMA BY: SPECIALTY LIGHTING AVAILABLE: 2', 4' AND 8' (NOT SHOWN) ON TOP OF MENUBOARD. ) SPECS: FIXTURE USES 1 - F14T5 BULB, 120V/.16A OR 277V/.07A FIXTURE USES 1 - F28T5 BULB, 120V/.28A OR 2 " "' 12A FIXTURE USES 2 - F28T5 BULBS, 12OV/.55A OR /.23A FIXTURES ON THE SAME WALL TO BE DAISY CHAINED REQUIRES ONLY A SINGLE OUTLET. \ 00000000 I \ ~M�" ` „sic 91. r-. [47.6cm] • \ to DD DISTRIBUTED SIZES MOUNTS = [wol• rl ! 12 3/4" - 1 17•_2" T5 FLUORESCENT LIGHT T5 FLUORESCENT LIGHT ELEC 32.4cm § O I r „i /2 0c [523.2cm] -- -' 1 /2 STE TYP. 2' 4' \ . DOUBLE PANEL TOP \ SINGLE . PANEL TOP 8' MULTIPLE AND ULTRA SLIMLITE 16 C/L '� \ E c I. [ w°L•6C] I L OD I L N I I ' I 00 M 0 '- - -tom 4' ULTRA SLIMLITE -2' . • ':L] I d 0 0 14 1/2" 8cm� = `- _ 03 r, E V M ENUBOARD '-' MANUFACTURER: VGS i \ U r7 M _ ' 1 3/8' DEEP 144.1 cm� c I. [wog. L9] I: ` „9l /C 9Z r, ` 1 „9 L/5 $'Z • [wog [ u- 10 2" L9] `-° „9 L/C 9Z ,� 5 DEEP ( [50.8cm] DEEP 38 5/8" >t ,_, N LEFT LEN., RIGHT LENS RIGHT LENS cm W/ CONTROL PANEL) [98.1 m] M ,z U to `-' [woz I „9 L/5 BD 1512 QUICK DROP CS 2820 CASH CONTROLLER TACO IIA CASH CONTROLLER POWER REQUIREMENTS: 110V AC OR 220V 50 CYCLE EDICATED CIRCUIT Z'C4 ® E .__, ,-, aT N N - A 8 PANELS (FOUR 2 PANEL UNITS) 1 - • Nt „9 L/5 -17Z MEASURES 24 1/2" X 197" INSERT SIZE: „ „ E 22 -1 /2 HIGH X 22 -1 /2 WIDE ao VISIBLE AREA: co 21 -1/2" HIGH X 21 -5/8" WIDE PANEL (FLAT DIMENSION): 24 -1/2" HIGH X 49 -1/4" WIDE X 3 -1/4" DEEP M -PG KICKPLATE PAINTED '-' E J �� u u u � u � i� BLACK ON (4) SIDES I I��� `--- �-' CUSTOMER SIDE HOT FOOD UNIT END VIEW \ C S C. S. S. S SAFES TIDEL SAFE „ -SHOWN ABOVE: 17 -2 FRONT COUNTER W/ RIGHT HAND 25 [83.5cm] HOT FOOD UNIT, ELECTRICAL SPECIFICATIONS \ \ \ n \ 3 n'= (2) 60 [152.4cm] COLD PAN UNITS AND 61 [154.9cm] CASH UNIT. -HOT FOOD UNIT: 120/60/1, 4.5A OR 220/50/1 3.5A. 500 WATTS. 24 5/8" 24 5/8" 24 5/8" NOTE: THESE DRAWINGS REPRESENT TYPICAL EQUIPMENT PURCHASED THROUGH DOCTOR'S ASSOCIATES INC. AND DOES NOT REPRESENT ANY EQUIPMENT PURCHASED LOCALLY BY THE FRANCHISEE/OWNER. OWNERS OF STORES OUTSIDE THE UNITED STATES AND CANADA MAY NEED ALTERNATE ELECTRICAL REQUIREMENTS. CONTACT YOUR DAI COORDINATOR OR THE MANUFACTURER FOR THE MODIFIED ELECTRICAL SPECIFICATIONS. -CASH L HAND AND RIGHT HAND WARMER UNITS AVAILABLE. » » UNIT LENGTHS AVAILABLE: 73"[185.4cm] 61 [154.9cm] 49"[124.5cm] 37 [94.Ocm] -COLD PAN�UNITS: 48" & 60" UNIT: 1 /3HP, 120/60/1, 8.5A OR 220/50/1, 3.8A 74" & 86" UNIT: 1 /2HP, 120/60/1, 8.5A OR 220/50/1, 4.5A / [62.5cm] / ,� di, [62.5cm] 9 �[62.5cm] 4 1/4 4 5/8 NOTE: 37 CASH UNIT DOES NOT HAVE SAFE CUT -OUT. -COLD PAN UNIT LENGTHS AVAILABLE: 86"[218.4cm] 74 "[188.Ocm] 60"[152.4cm] 48 '[121.9cm]. -HOT FOOD UNIT LENGTHS AVAILABLE: 61 [154.9cm] 49 [124.5cm] 37 [94.Ocm] 25"[83.5cm]. -6 PREWIRED ELEC. OUTLETS BUILT INTO CASH UNIT FOR COLD PANS, HOT FOOD UNIT, POS POWER CONDITIONER, PRINTER, ETC. 20' PREWIRED CONDUIT. (NEMA #5 -15) [125.1cm] / D OUBLE PANEL FRONT SINGLE PANEL FRONT [11.7cm] - EXTENSIONS TO HOT FOOD, CASH UNITS AND CASH /BEVERAGE END UNITS AVAILABLE - ELECTRICAL CONNECTIONS MUST COMPLY WITH LOCAL AND STATE CODES. SIDE AT 12 "[30.5cm] 24 "[61cm] 36 "[91.4cm] 48 "[121.9cm] 60 "[152.4cm] AND 72 "[182.9cm]. - (26 '[66.Ocm] EXTENSION WITH ADDITIONAL CASH DRAWER ALSO AVAILABLE). -NSF AND ULS APPROVED -C -UP AND UP LISTED DUKE FRONT COUNTER VGS MENUBOARD WITH ULTRA SLIMLITE DATE: 10 -31 -08 DESIGNED BY: PATRICK ROSE DRAWN BY: PMR REVIEWED BY: PMR SCALE: NOT TO SCALE ' C I STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ( "DAI") D /B /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND /OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAPS AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAPS STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. REVISION: REVIEWED Q ;ODE COMPLIAW I APPROVED MAD I gnnn ,. LUUJ I•VA... _At...-. a .. %my ui I uKwiia B UILDING DIVISION >- m W Q a SHEET #: 40f4 ©2008 DOCTORS ASSOCIATES, INC. FLOOR FINISH LEGEND- TUSCANY II DECOR (PERIMETER GREEN PATTERN) TILE NO. AREA OF STORE MANUFACTURER SUPPLIER INST. SQ /FT DESCRIPTION CO CUSTOMER AREA CROSSVILLE G.C. GC, 63 COLORBLOX STONE SERIES; 12" X 12" A1153 CLAY WITH DARK GREY OR DARK BROWN GROUT. 0 CUSTOMER AREA/ PUBLIC ACCESSIBLE RESTROOM CROSSVILLE G.C. G.C. 475 COLORBLOX STONE SERIES; 12" X 12" A1156 WHEAT WITH DARK GREY OR DARK BROWN GROUT. O CUSTOMER AREA CROSSVILLE G G.C. 415 COLORBLOX STONE SERIES; 12" X 12" A1154 GREEN WITH DARK GREY OR DARK BROWN GROUT. 0 SERVICE/ BACKROOM AREA CROSSVILLE G.C. G.C. 430 OPTION #1: COLORBLOX STONE SERIES; 12" X 12" A1156 WHEAT WITH DARK GREY OR DARK BROWN GROUT. OPTION #2: 51830 COLOR: COTTAGE TAN 12" X 12" VINYL COMPOSITE TILE CONTINUED THROUGHOUT THE BACKROOM. ARMSTRONG G.C. G.C. WALL BASE NOTE,: WALL BASE OPTION MUST MATCH FLOOR OPTION LISTED ABOVE IN ALL AREAS OF STORE CUSTOMER AREA CROSSVILLE G.C. G.C. DAI 6" X 12" COVE BASE OR 4" X 12" BULLNOSE: COLORBLOX STONE SERIES A1154 GREEN WITH DARK GREY OR DARK BROWN GROUT. 6" X 12" COVE BASE OR 4" X 12" BULLNOSE: COLORBLOX STONE SERIES A1156 WHEAT WITH DARK GREY OR DARK BROWN GROUT. RESTROOM / BACKROOM SERVICE AREA CROSSVILLE G G,C. 6" BLACK VINYL COVE BASE. (USED WITH VINYL COMPOSITE FLOOR TILE ONLY) SERVICE /BACKROOM AREA ARMSTRONG G G.C. ADDITIONAL COMMENTS: 1.) FLOORING CONTRACTOR IS RESPONSIBLE FOR OWN DETERMINATIONS ON SUBFLOOR REQUIREMENTS AND TO INSTALL IN ACCORDANCE WITH CODE REQUIREMENTS AND TO INDUSTRY AND MANUFACTURER SPECIFICATIONS. 2.) THE SQUARE FOOTAGE CALCULATIONS OF THE FLOORING MUST BE VERIFIED BY THE G.C. AND FRANCHISE OWNER. SUBWAY STORE DESIGN DEPARTMENT WILL NOT ACCEPT RESPONSIBILITY FOR ANY INACCURACIES. 3.) BULLNOSE WALL BASE IS TO BE INSTALLED ON TOP OF THE TUSCAN STUCCO WALL COVERING. 1 " -3" OF TUSCAN STUCCO WALL COVERING IS RECOMMENDED TO BE COVERED TO PROVIDE A TIGHT FIT. SEE MANUFACTURER FOR SPECS. 220V. INSTALLED BY G.C. 3' WALL ART - VERTICAL I ...:.. ' 3 23" X 50" WALL HUNG PRINT(S) ON STYRENE -FACED FOAMBOARD FRAMED IN BLACK METAL. MOUNTING HARDWARE INCLUDED. EIGHT DIFFERENT PRINT IMAGES AVAILABLE. ;: i SUNGLO FABRICS DAI ` ........ FLOOR PATTERNS (CUSTOMER AREA) A1153 A1156 CLAY WHEAT USING 12" X 12" CROSSVILLE COLORBLOX SERIES TILE DATE: JANUARY 7, 2008 DESIGNED BY: PETER SEELEY/ DAVE SURA DRAWN BY: PMD REVIEWED BY: SCALE: 1/4" = 1' -0" ,ry .1 T �� +. c. � P i J I FR ) I �s 7 I UPGRADE TO "TUSCANY II" GLlId QTY. DESCRIPTION FURNITURE AND EQUIPMENT LEG-I.E VD ITEM MANUFACTURER ORDERED act 0, QTY. DESCRIPTION CUSTOMER AREA 1 BOOTH SEATING PLYMOLD DAI 2 (1)4- SEATER ( )2- SEATER ( )3- SEATER ( )2 -SEAT HANDICAP (1)4 -SEAT HANDICAP. (X)CONTOUR UCOLORCOURT. BENCH AND TABLE TOP (WITH BLACK DURA -EDGE) COLOR: FONT HILL PEAR LAMINATE. 48 20" X 24" TABLE PLYMOLD DAI 18 30" HIGH W/ FREESTANDING 22" X 22" CROSS BASE. FONT HILL PEAR LAMINATE WITH BLACK DURA EDGE. 5A 30" ROUND BAR HEIGHT TABLE PLYMOLD DAI 3 42" HIGH W/ FREESTANDING 30" X 30" CROSS BASE. FONT HILL PEAR LAMINATE WITH BLACK DURA EDGE. 6A CHAIR PLYMOLD DAI 38 9 1 QUEST CHAIR W/ UPHOLSTERED SEAT OR DUR -A -SEAT TO BE ORDERED IN THE FOLLOWING COLORS: CROCUS, SPICE AND SLATE. FRAME COLOR IS BLACK WRINKLE. 68 8A BAR HEIGHT STOOL PLYMOLD DAI QUEST STOOL W/ UPHOLSTERED SEAT OR DUR -A -SEAT TO BE ORDERED IN THE FOLLOWING COLORS: CROCUS, SPICE AND SLATE. FRAME COLOR IS BLACK WRINKLE. TRASH RECEPTACLE PLYMOLD DAI SINGLE HOLE TRASH UNIT. 25" X 25" BLACK DURA EDGE TRASH RECEPTACLE W /FONT HILL PEAR LAMINATE FINISH. 9 SODA FOUNTAIN CORNELIUS DAI 1 DEDICATED 115V, 20 AMP DUPLEX OUTLET (NEMA 5 -20R) W/IN 3 FEET, 3 INCH OR LARGER FLOOR DRAIN W /IN 3 FEET (EQUIPMENT INSTALLED BY COKE). 10 BEVERAGE DESTINATION CENTER DUKE MANUFACTURING DAI 1 (X )RH ( )LH BEVERAGE PLACEMENT ( )48" ( )60" ( X )72" ( )84" ( )96" ( )108" ( )120 ". STAINLESS STEEL TOP. FONT HILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 11 RED NEON "OPEN" SIGN Di CDRPAISCN DO AY/t OI GLASS Kfas DAI/G.C. 1 SEE MANUFACTURER FOR SPECS. 220V. INSTALLED BY G.C. 13A WALL ART - VERTICAL SUNGLO FABRICS DAI 6 23" X 50" WALL HUNG PRINT(S) ON STYRENE -FACED FOAMBOARD FRAMED IN BLACK METAL. MOUNTING HARDWARE INCLUDED. EIGHT DIFFERENT PRINT IMAGES AVAILABLE. 13B WALL ART - SQUARE SUNGLO FABRICS DAI 2 26" X 26" WALL HUNG PRINT(S) COLOR PHOTOS DOUBLE MATTED IN A BLACK WOODEN FRAME. MOUNTING HARDWARE INCLUDED. EIGHT DIFFERENT PRINT IMAGES AVAILABLE. 14 CHIP RACK FRITO -LAY DAI 1 ( )44 "W X 16 3 /B "D X 6B "H ( )44 "W X 16 3/8 "D X 541H (X)33 1/4 "W X 16 3/8'D X 68 "H FLOOR RACKS. / ( )24 "W X 12 "D X 22 "H ( )36 "W X 12 "D X 22 "H COUNTERTOP RACKS. THROUGH LOCAL DIST. 15 DISPLAY REFRIGERATOR TRUE DAI 1 ( X )1 DOOR FLOOR MODEL ( )2 DOOR FLOOR MODEL. DEDICATED 115V, 15 AMP DUPLEX OUTLET (NEMA 5 -15R) ON 6 FEET. 16 WALL PLANT GRACE DESIGNS DAI 1 WALL HUNG SILK PLANT. MOUNTING BRACKET TO BE HUNG 15" BELOW THE TOP OF THE UPPER DECORATIVE MOLDING (REFER TO TUSCANY II BACK -UP SHEET #1) 17 INTERIOR DOOR LOCAL G.C. 1 SOLID CORE HARDWOOD DOOR (SLAB OR PANEL CONSTRUCTION) STAIN MINWAX j235 CHERRY & POLYURETHANE W/ MINWAX FAST DRYING SA11N. METAL FRAME (PAINT SHERWN WIWAMS 1SW6356 COPPER MOUNTAIN) LEVER HANDLE. INSTALLED BY GC. SERVICE AREA 19 FRONT COUNTER DUKE MANUFACTURING DAI 1 TOTAL 17' -2" ( X )LH ( )RH 25" HOT FOOD UNIT ( 2 ) 60" COLD PAN UNIT s1" CASH UNIT. FOOD EXTENSION N/A CASH EXTENSION N /AAEVERAGE EXTENSION. LENGTH _N,AAHOT INSTALLED BY G.C. ULS APPROVED. ELECTRICAL CONNECTIONS AND WIRING TO LOCAL AND STATE CODE REQUIREMENTS AS DETERMINED BY G.C. OR ELECTRICIAN. 21 COOKIE DISPLAY CASE ADVANCED DISPLAYS IN PLASTICS, INC DAI 1 DISPLAY CASE ON TOP OF SUB -WRAP AND NAPKIN RISER. MADE • OF CLEAR 'ACRYLIC. 23 24 SAFE C.S.S, fTIDEL DAI T TT TT TIME LOCK ( X )QUICK DROP ( )TIDEL TACO. INSTALLED BY G.C. IN SERVICE AREA. SUBSHOP 2000 P.O.S. MICROS SYSTEMS /DELL /SUBTOTAL DAI PC BASED POINT OF SALE SYSTEM. REQUIRES DEDICATED POWER SOURCE WITH ISOLATED GROUND TO BREAKER. 25 MICROWAVE AMANA /SHARP DAI *5 -20R OUTLET REQUIRED. 1200 WATT, 120V /60HZ /1PH, 20 AMP CIRCUIT. DEDICATED CIRCUIT REQUIRED. 27 28A BREAD OVEN NU -VU DAI NU -W. DEDICATED CIRCUIT REQUIRED. DIRECT WIRED. INSTALLED BY G.C. NSF APPROVED. *1/4" WATERUNE IS REQUIRED. ENCLOSED BREAD CABINET NU -VU DAI NU -W. INSTALLED BY G.C. NSF APPROVED. 2 BC 29 OPEN AIR COOUNG RACK MENUBOARD LOCKWOOD VGS . TRANSUTE SONOMA DAI DAI 1 4 HALF RACK -30 "H X FULL RACK -64 "H. 21 1 4 " "W x 26 1 2 "D. INSTALLED BY G.C. NSF APPROVED. MENUBOARD: ( 4 )2' X 4' ( )2' X 2'. LIGHT FIXTURES: ( )2' ( )4' ( )8' ( 1 )16' MOUNT TO TOP OF MENUBOARD. SINGLE OUTLET REQUIRED. INSTALLED BY G.C 30 COUNTER ENTRANCE PLYMOLD /DUKE MFG. DAI 1 SELF - CLOSING, PREFRAMED & PREFINISHED OR SEE BACK -UP SHEETS FOR CONSTRUCTION SPECS. FONTHILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 31 BACK COUNTER W/ HAND SINK DUKE MANUFACTURING DAI 1 )RH ( X )LH ( )CENTER HAND SINK. ( )24" ( )36" ( X )48" ( ) ( )72" LENGTH. STAINLESS STEEL TOP. FONT HILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 33 REFRIGERATED BACK COUNTER DUKE MANUFACTURING DAI 1 ( X )48" LENGTH. ( )60" LENGTH. BACK COUNTER WITH UNDER - COUNTER REFRIGERATOR. STAINLESS STEEL TOP. FONT HILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 34 RAPID COOK OVEN TURBOCHEF /MERRYCHEF DAI 1 ( X )TURBOCHEF ( ) MERRYCHEF MICROWAVE /CONVECTION OVEN. REFER TO TUSCANY II BACK -UP SHEET #4 FOR FURTHER SPECIFICATIONS. BACKROOM AREA 36 SINK DUKE MANUFACTURING DAI 1 ( 3 )COMPARTMENT(S) ( 2 )DRAINBOARD(S). ( X )18" ( )24" DRAINBOARD SIZE. INSTALLED BY G.C. ULS APPROVED. 37 MOP SINK LOCALLY SOURCED G.G. 1 FLOOR LEVEL SINK. 2' X 2' (PREFERRED). ACQUIRE LOCALLY. INSTALLED BY G.C. 38 HOT WATER TANK LOCALLY SOURCED G.C. 1 ACQUIRE LOCALLY. INSTALLED BY G.C. 39 S.S. WORKTABLE DUKE MANUFACTURING DAI 1 p4" ( )36" ( J48" ( )60" (X )72" ( )84" ( )96" )108" ( )120" X 30 ". ( X )W/ GALVANIZED UNDERSHELF ( )WITHOUT UNDERSHELF. 40 WALL SHELF INTER METRO DAI , 3 SUPER ERECTA BRITE. EPDXY COATED, WALL MOUNTED SHELVES, AVAILABLE IN VARIOUS SIZES. INSTALLED BY G.C. 41 42 VEGETABLE SINK HAND SINK DUKE MANUFACTURING DUKE MANUFACTURING / LOCAL SSDC DAI DAI/G.C. DAI ( 1 )COMPARTMENT(S) ( 1 )DRAINBOARD(S). ( X )18" ( )24" DRAINBOARD SIZE. INSTALLED BY G.C. ULS APPROVED. WALL MOUNTED, 10" X 14" X 6 ", OR SEE OWNER FOR SPECS. SUBJECT TO HEALTH CODE APPROVAL. 43 CLEANING PRODUCT RACK DISPENSING STATION FOR CLEANING PRODUCTS. 45 NEMCO EASY - SLICER NEMCO, INC. DAI 1 MANUAL SLICER MOUNTED ON STAINLESS STEEL TABLE TOP. NSF APPROVED. 46 RETARDER CABINET LOCKWOOD DAI 1 e I - I�I X )WALK -IN ( )REACH -IN . NSF APPROVED. 47 48 49 50 51 REFRIGERATOR OR F T FREEZER STORAGE UNITS SODA STORAGE 0 LAK E N R NORLAKE INTER METRO DAI DAI DAI - INSTALLED BY G.C. NSF APPROVED. RA G. DIRECT WIRED DOOR )2 DOOR )1 DOOR O1HER SELF EVAPO TIN )6' 6' 5'X6' )4' )3 R 8' X 6 X )6' 8 ( ) 6 X ) 8 X ) ( ) ) ( ) ( ) ( ( )8' X 6' ( )6' X 8' ( X )6' X 6' ( )5' X 6' ( )4' X 6' ( )3 DOOR ( )2 DOOR ( )1 DOOR ( )OTHER SELF- EVAPORARNG. DIRECT WIRED. INSTALLED BY G.C. NSF APPROVED. ( 1 )18" X 60" ( 3 )24" X 72 ". SUPER ERECTA BRITE. COKE DAI DEDICATED 115V, 20 AMP DUPLEX OUTLET (NEMA 5 -20R) W/IN 3 FEET OF BIB RACK, 96 INCHES HIGH/WATER J2 INCH BALL VALVE SHUTOFF W/IN 3 FEET OF BIB RACK, 96 INCHES HIGH (EQUIPMENT INSTALLED BY COKE). RECEIVER AND AMPLIFIER WITH THREE SPEAKERS MOUNTED AND PROFESSIONALLY WIRED IN CEILING. OPTIONAL SUBWAY® RADIO SERVICE. STEREO SYSTEM SUBWAY® RADIO /LOCAL DAI/LOCAL 1 11111111111 1 111 P 111111111111111111 II11I11111IIIIIE %1IIu 11111111111 11111` ?IiI 111111111111 IIIIIuuuuuul I ll ull 111111111111111111111111111111111111 1111111111111111V111111111111111111 1/1111111111111r , • 11IIIIIIIU11111 11111M1111111111466111111111111111 11111111111111U11 MI1111111111111 It is s trop I eco rn n r m e ded that hot Ovate fior gY r. •the res roo t . 0) hand •ash "sinks be plumbed m Ovate • ° troth ' o r h h t eate : in tea '" ' U :;.. a nstaht war "` type w heater unit under each sin tii rly IIr mem r a ixy s 'f; ' E E RAT( O N A ND • H O � N ALL!; J S YSTEMS: SH DIS EAK UI O MEETHE T P .d =,,:� :'1 ,,,...:,Ins •, \„ : ; "..:.: ;'. WA DEMANDS THROUGHOUT T FO LISHMENT , Food:equlpmdrIt that Is :c rtlhed(or sa nitation by ari A merican N a tio nalySta1dards IrisUtute (AN accredited e w com wi the food cod equipment & utensil rgatehal construction and design requirements , LOCKERS OR OTHER SUITABLE FACILITIES SHALL BE PROVIDED FO THE ORDERLY STORAGE OF EMPLOYEES' CLOTHING AND OTHER POSSESSIONS. AP PRovEE 91.15.IE r,.: TO + y1R'1. ii',i CO TYP. NO CHANGES SHALL B! MADE WITHOUT HEALT DEPARTMENT APPROV, O 4 1 C 17' -2" 0 EXISTING RESTROOM ENTRANCE 1 3O "X48" CLEAR r SPACE REQUIRED J 3'0" X 6'8" 3' -11" 10" / / . =. Y. !, Y � "' 'a'i,:?i` R ES„TROOM & KITCHEN HAND IN ASH,SINKS SHALL BE # T E r= AT PER . U R TER AT O PROVIDE W . M A EQUIPP.E T HEI THROU A DEGREE FA T. LEAST:100 s.OF L� A TI O N FAUE SE F. ..,._ EORC OMB IN M XING. VALV L CLOSING OR M FA UCETS SHA fLOWOF WATER FOR A T LEAST 15 SECONDS 4B TYP. 13 TYP. N 4. n 0 17'- 6" A1NBOARDSI UTENSIL RACKS OR BLS$ LARGE E NOUGH TO C OM MODATE ALL SOILEDAND CLEANED TEMS SHALL BE PROVIDED FOR NECESSARY UTENSIL; HOLDING .BEFORE CL EANING AND AFTER SANITIZING. 0 0 1 N'. BE AD SED' VI TH T A THE NEW WASHINGTON r 'StATE FOOD CODE REQUIRES . COMMERC .; , 61'4 IAL, REFRIGERATI TO HOLD FOOD AT 41 DEGREES FAHRENHEIT OR BELOW !!! (DOWN FROM 45 DEGRE ( 00. 1tv SrD'(S ICE ON TOP 0 66' 0 F T FO UP S E , ,.> RVI C " EO OPERA A TI ON AR 'FLOOR' COVE A ` •• FA FL ERINGS, WALLS WALL COVERINGS, AND CEL NG S SHALL`BE•:: • DE CONSTRUCTED ANDINS SO THEY ARE SMOO `DURABLE AND 'EASILY CLEANABLE 1 • IrA X42" I MOUNT ON SHELF u ABOVE #38 HEADERWALL C6' -8" A.F.F 11111111111111111111111111111 IIIu1I1111IMlIHH lIfl I11l111111k1. J1l1Ill1U1I11 WALL MOUN 1 11111111111111111111111111111111111 11111111111111111 111111111111111111 IIIOIIIUuI1 Ir�111111111111111 11/1111111 11111 Jllllllllllllll 111111111 111111114111111111111111 111111111111 111111111111111111111. 1 (';i: 6) L___J DIRECT WIRED ROLLING GATE LA PLUMBING SYSTEMSHALL BE DESIGNED CONS CONS TRUCTED AND,.:IN TALLED , «, ;d,.,.,,�,,, x ...ti,, , . AC CORDING,TO LAW STATE, AND FEDERALSTATUES, REGULATIONS AND ORD■NANC 12' -7" 30' -3" a 0 0 L.H c� O 36" HIG WALL 3' -2" „FOOD, FOOD PREPARATION AND FOOD D :SERVICE E EQUIPMENT PMENT STOR " AGE:ARE -. AS ARE E PROHIIBITED'UNDER SEWER LINES .THAT ARE NOT SHIELDED TO : INTERCEPT POTENTIAL DRI S. MODEM UNE (REQUIRED) ABOVE #34 8 PANELS 6' -8 "C REWASHING/DISHWASHING SINK O MRARTMENTS SHALL BE LARGE EN OUGH TO ACCOMMODA t VI MERSION OF.THE LARGEST QUIPMENT AND UTENSILS. 0 8' -10 1/4" 8' -10" N- 2' -8 1 /4" 21' -2" 11 -8" N N INCOMPLETE RE EIVED LTR# CITY OF TUKWILA FEB 10 2009 PERMIT CENTER - APPLICANT COPY IVIEWED FOR CODE COMPLIANCE APPROVED MAR 12 2009 City of Tukwila BUILDING DIVISION 120°\ -012 NEW LOCA TION GENERAL NOTES: CEILING HEIGHT IS 20' ELECTRICAL OUTLET HEIGHTS MEASURED TO BOTTOM OF BOX. ONE ELECTRICAL JUNCTION BOX TO BE LOCATED IN CEILING ABOVE EACH WINDOW. STORE DESIGNED WITH CONTOUR SEATING. SHOWN ON PLAN AS SINGLES NOT GROUPS. CUNO MODEL SW3 -PLUS WATER FILTRATION SYSTEM IS REQUIRED IN ALL NEW STORES THAT DISPENSE BEVERAGES. THE RECOMMENDED PLACEMENT FOR INSTALLATION IS MOUNTED TO SODA SYRUP RACK BY COCA -COLA. SECONDARY PLACEMENT OPTION IS MOUNTED ON THE BACKROOM WALL. THIRD INSTALLATION OPTION IS MOUNTING INSIDE THE FRONT BEVERAGE COUNTER WHEN SPACE LIMITATIONS OCCUR. REQUIRED: 1/2" INCOMING WATER LINE FEED WITH 1/2" BALL VALVE SHUTOFF AND 1/2" FPT CONNECTION. MINIMUM 110 VOLT, 20 AMP ELECTRICAL SERVICE TO SUPPORT THE CARBONATOR AND WATER BOOSTER (MUST BE DEDICATED CIRCUIT). SMARTCURVE STAND (MFR. DISPLAY -BOX) REQUIRED IN CUSTOMER AREA AT POINT OF ORDER (PREFERRED PLACEMENT). 21 3/4" X 13 1/8" BASE, 56" (WITHOUT HEADER) OVERALL HEIGHT. EXIT LIGHTS INSTALLED BY G.C. PER LOCAL CODE. EMERGENCY LIGHTS INSTALLED BY G.C. PER LOCAL CODE. EXTINGUISHERS, SMOKE AND FIRE DETECTION SYSTEMS INSTALLED BY G.C. PER LOCAL CODE. LABOR & MATERIAL SUPPLIED BY G.C. UNLESS OTHERWISE NOTED. ALL DIMENSIONS TO BE VERIFIED BY G.C. ON SITE. DECOR SPECIFICATIONS ARE TO BE SUBWAY'S "TUSCANY II" SCHEME. REFRIGERATOR AND FREEZER MUST BE ADEQUATELY VENTILATED. REFER TO MANUFACTURER FOR DETAILS. THE D.A. MUST CONFIRM THAT SUBWAY WILL SHARE OR BE PROVIDED SPACE FOR THE FOLLOWING ITEMS: RESTROOM ACCESS. VISIBILITY INTO BACKROOM THROUGH GLASS MUST BE OBSCURED. STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS ENSURING FOR ENS F RESPONSIBLE COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAPS STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ( "DAI") DIB /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR ANDIOR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAI'S AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAPS STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. oc o� SHEET #: lof 2 02008 DOCTORS ASSOCIATES, INC. STORE #42522 DEVELOPMENT AGENT: A rl H REQEIVED CITY OF TUKWILA FEB 101009 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED MAR 12 2009 City of Tukwila BUILDING DIVISION . INCOMPLETE CORR`C''TION LTR# LTR # PAKTIAL P1-?4K PLAN - SUbbd&Y T.L DM? 1 / `t = 1 o" H II I I ILJ! • tut.\ \\\ "\ \ \ \ \\ \L\ \ tAj L— I DEMO EXISTING EQUIPMENT , CASEWORK AND FURNISHINGS WITHIN PRO.JEG AREA AS DIRECTED BY OWNER .2223.2 .\'t2h \*ham `.4 2,••••,222. Copyright © 2008 Fredrick J. Angelo: All Rights Reserved. REVIEWED FOR CODE COMPLIANCE APPROVED MAR 12 2009 RECEIVED CITY OF TUKWILA FEB 0 2 2009 PERMIT CENTER Revision Schedule Number I Date I Revision Description Sheet Contents: DEMO PLAN Drawing Scale: 1 /4" = 1' -0" Project Issue Date: 11/15/2009 Drawn By: hNGELO SNEET NUMbEK Sheet Issue Date: 11/15/2009 Checked By: hNGEL0 3 2 3 NQKTI1 FIRST FL22K KEY PLAN I =50 O ., T PARTIAL FL99R PLAN - SUBWAY T.i. (SMELL 9NLY) I /`t"= PRO.IEGT ARE.A WHICH 4" METAL STUD WALL / T1.5 5 3 EXISTING WALL Uh:DER51::'E OF STRUCTURE METAL STUD BRACING ALTERNATE DIRECTION e4' -0" O .G. (TYP) i 1/2 "= 1' - 0" 20' — " C e ?"' TENANT ° 5/E'" GWS ON SUBWAY SIDE BY TENANT WALL FINISH BY TENANT BASE SY TENANT FINISH FLOOR SY TENANT METAL STUD WALL SECT19N 4k ;t ; Sim NEW WALL T1.7 / / / / / / / / / , / Ti 56" HIGH WALL ci'HIGH 4" METAL STUD WALL p ro t.,41.4 Q sic GURTIAN WALL SOVE TO MATCH EXISTING 01 /2" SANDWICC1 P RE P 1 Ti. 1 T2. 2T2.3 in 6" m 5/S" GWS ON STORE GROCERY SIDE METAL STUD FRAMING @ 16' O.G. (SEE FLAN FOR SIZE) 5/8" EXPANSION BOLTS 24" O/C, RUNNER CHANNEL TOP OF EXISTING CMU WALL EXIST. GK.) WALL (HEIGHT VARIES) Sim rrscr AREA V N \ I ttl .--- 6" METAL STUD PLUMBING WALL HEIGHT 1 3 METAL STUD b:'ALL SECTI2N 2 i 1 /2" = 1 , -0„ +IAA. 9 rOZeN t v -' 4iK r ,wCrS4eriw'g' " +' 4.uRiefa ` R;:3�•�,: Revision Schedule Number I Date I Revision Description z O: vi Sheet Contents: FLOOR PLAN DETAILS Drawing Scale: As indicated Project Issue Date: 11/15/200 Drawn By: Sheet Issue Date: 11/15 /GOOa Checked By: ANGELO SKEET NUMBER T2.5 uNDERSIPE OF S T RUC T URE METAL STUD 'RAGING ALT.RNA T E DIRECTION @4' -0" O.G. (TYP) CEILING F IT WALL FINISH BY TENANT 5/S," GYMS ON SUBWAY SIDE 5Y TENANT BASE BY TENANT FINISH FLOOR 'BY TENANT EXISTING GMU WALL NEW 6" METAL STUD PARTITION ON TOP OF EXISTING GMU WALL EXISTING CMU WALL l MEANS OF EGRESS ILLUMINATION IBC 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. IBC 1006.2 Illumination level. The means of egress illumination level shall not be less than `1 foot - candle at the "walkirig'level] IBC 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways.. 3. Exterior egress components... 4. Interior exit discharge elements 5. Exter'or'",I - dins 'for exit di a q do omays.:' ,—r FASTEN 'BOTTOM TRACK TO FLOOR @ 24" OS MAX Copyright c 2008 Fredrick J. Angelo; All Rights Reserved. 5/8" GWS SY TENANT METAL STUD FRAMING @ 16" O.G. (SEE PLAN FOR SIZE) REV E` ED r CODE COP,. N SCE APE OV -2D MAR 1 2 2U City of Tukwila BUILDING DIVISION CITY RECEIVE TUKV°VILA FEB 0 2 2000 PERMIT CENTER O (r) c� Lfl I 0 r 6 I e co (-4 NJ 2 O: V t_1 U 0: oG t:_.l 0: t�J z (.1 0 Go 1 LL1 Z 3 i v) z 'LI 3= r) ii...t v.) r 3 I .< o: qtac DATE: JANUARY 7, 2008 DESIGNED BY: PETER SEELEY / DA S • 'A DRAWN BY: PMD R ggi ‘ B ‘,4 SCALE: 1/4" QTY 1 — -0 n REVISION: ITEM UPGRADE TO "TUSCANY 11" O QTY DECOR CHANGES G d I swr/c M I M ��I T I�I�I ^ I M IN�� F URNI T URE AND EQUIPMENT LEGEND ITEM MANUFACTURER ORDERED FROM QTY DESCRIPTION CUSTOMER AREA 1 BOOTH SEATING PLYMOLD DAI 2 (1 )4— SEATER ( )2— SEATER ( )3— SEATER ( )2 —SEAT HANDICAP (1)4—SEAT HANDICAP. ( X )CONTOUR ( )COLORCOURT. BENCH AND TABLE TOP (WITH BLACK DURA —EDGE) COLOR: FONT HILL PEAR LAMINATE, 4B 20" X 24" TABLE PLYMOLD DAI 18 30" HIGH W/ FREESTANDING 22" X 22" CROSS BASE. FONT HILL PEAR LAMINATE WITH BLACK DURA EDGE. 5A 30" ROUND BAR HEIGHT TABLE PLYMOLD DAI 42" HIGH W/ FREESTANDING 30" X 30" CROSS BASE. FONT HILL PEAR LAMINATE WITH BLACK DURA EDGE. 6A CHAIR PLYMOLD DAI QUEST CHAIR W/ UPHOLSTERED SEAT OR DUR —A —SEAT TO BE ORDERED IN THE FOLLOWING COLORS: CROCUS, SPICE AND SLATE. FRAME COLOR IS BLACK WRINKLE. 6B BAR HEIGHT STOOL PLYMOLD DAI QUEST STOOL W/ UPHOLSTERED SEAT OR DUR —A —SEAT TO BE ORDERED IN THE FOLLOWING COLORS: CROCUS, SPICE AND SLATE. FRAME COLOR IS BLACK WRINKLE. 8A TRASH RECEPTACLE PLYMOLD DAI SINGLE HOLE TRASH UNIT. 25" X 25" BLACK DURA EDGE TRASH RECEPTICLE W /FONT HILL PEAR LAMINATE FINISH. 9 SODA FOUNTAIN CORNELIUS DAI DEDICATED 115V, 20 AMP DUPLEX OUTLET (NEMA 5 -20R) W /IN 3 FEET, 3 INCH OR LARGER FLOOR DRAIN W /IN 3 FEET (EQUIPMENT INSTALLED BY COKE). 10 BEVERAGE DESTINATION CENTER DUKE MANUFACTURING DAI ( X )RI-1 ( )LH BEVERAGE PLACEMENT ( )48" ( )60" ( X )72" ( )84" ( )96" ( )108" ( )120 ". STAINLESS STEEL TOP. FONT HILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 11 RED NEON "OPEN" SIGN MN DOFP.JHNSON DISRAYJNEON GLASS KW DAI /G.C. SEE MANUFACTURER FOR SPECS. 220V. INSTALLED BY G.C. 13A WALL ART — VERTICAL SUNGLO FABRICS DAI PRINT IMAGES AVAILABLE. W E INCLUDED. EIGHT DIFFERENT P I 23 X 50" WALL HUNG PRINT(S) — FOAMBOARD HARDWARE ON STYRENE FACED F AM ARD FRA MED IN BLACK METAL. MOUNTING HARD 138 WALL ART — SQUARE SUNGLO FABRICS DAI 26" X 26" WALL HUNG PRINT(S) IMAGES AVAILABLE. COLOR PHOTOS DOUBLE MATTED IN A BLACK WOODEN FRAME. MOUNTING HARDWARE INCLUDED. EIGHT DIFFERENT PRINT M 14 CHIP RACK FRITO—LAY T DAI M THROUGH LOCAL DIST. 1 " 22 H COUNTERTOP RACKS 6" FLOOR RACKS. 24 "W X 2 "D X 22 H 36 W X 2 D X 16 "D X X 331 4 "WX163 8 "D X 8H FLO R R 1 44 "W X 16 3 8 "D X 68 "H 44 "W X 6 3 8 / ( ) ( ) ( / ( ) / ( ) / / 15 DISPLAY REFRIGERATOR TRUE DAI 1 (X )1 DOOR FLOOR MODEL ( )2 DOOR FLOOR MODEL. DEDICATED 115V, 15 AMP DUPLEX OUTLET (NEMA 5-15R) W / IN 6 FEET. 16 WALL PLANT GRACE DESIGNS DAI 1 WALL HUNG SILK PLANT. MOUNTING BRACKET TO BE HUNG 15" BELOW THE TOP OF THE UPPER DECORATIVE MOLDING (REFER TO TUSCANY II BACK -UP SHEET #1) 17 INTERIOR DOOR LOCAL G.C. 1 SOUD CORE HARDWOOD DOOR (SLAB OR PANEL CONSTRUCTION) STAN MINWAX 1235 CHERRY & POLYURETHANE W/ MINWAX FAST DRYING SATIN. METAL FRAME (PAINT SHERWIN WIWAMS /SW6356 COPPER MOUNTAIN) LEVER HANDLE. INSTALLED BY GC. SERVICE AREA 19 FRONT COUNTER DUKE MANUFACTURING DAI 1 TOTAL LENGTH 17' -2" ( X )LH ( )RH FOOD UNIT ( 2 ) 60" COLD PAN UNIT 61" CASH UNIT. N/A HOT FOOD EXTENSION N/A CASH EXTENSION N/A BEVERAGE EXTENSION. _ ...2 .HOT INSTALLED BY G.C. ULS APPROVED. ELECTRICAL CONNECTIONS AND WIRING TO LOCAL AND STATE CODE REQUIREMENTS AS DETERMINED BY G.C. OR ELECTRICIAN. 21 COOKIE DISPLAY CASE ADVANCED DISPLAYS IN PlASi1CS, INC DAI 1 — DISPLAY CASE ON TOP OF SUB WRAP AND NAPKIN RISER. MADE OF CLEAR ACRYLIC. 23 SAFE C.S.S. /T1DEL MICROS SYSTEMS /DELL /SUBTOTAL DAI DAI 1 1 ( )TIME LOCK ( X )QUICK DROP ( )T1DEL TACO. INSTALLED BY G.C. IN SERVICE AREA. PC BASED POINT OF SALE SYSTEM. REQUIRES DEDICATED POWER SOURCE WITH ISOLATED GROUND TO BREAKER. 24 SUBSHOP 2000 P.O.S. 25 27 MICROWAVE BREAD OVEN AMANA SHARP DAI *5 -20R OUTLET REQUIRED. 1200 WATT, 120V /60HZ /1PH, 20 AMP CIRCUIT. DEDICATED CIRCUIT REQUIRED. NU —W DAI NU —VU. DEDICATED CIRCUIT REQUIRED. DIRECT WIRED. INSTALLED BY G.C. NSF APPROVED. *1/4" WATERLINE IS REQUIRED. 28A ENCLOSED BREAD CABINET NU —VU DAI NU —VU. INSTALLED BY G.C. NSF APPROVED. 28C OPEN AIR COOLING RACK LOCKWOOD DAI 1 ( )HALF RACK -30 "H ( X )FULL RACK-64"H. 21 1/4' "W x 26 1/2 "D. INSTALLED BY G.C. NSF APPROVED. MENUBOARD: ( 4 )2' X 4' ( )2' X 2'. LIGHT FIXTURES: ( )2' ( )4' ( )8' ( 1 )16' MOUNT TO TOP OF MENUBOARD. SINGLE OUTLET REQUIRED. INSTALLED BY G.C. 29 MENUBOARD VGS / TRANSLITE SONOMA DAI 30 COUNTER ENTRANCE PLYMOLD /DUKE MFG. DAI SELF — CLOSING, PREFRAMED & PREFTNISHED OR SEE BACK —UP SHEETS FOR CONSTRUCTION SPECS. FONTHILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 31 BACK COUNTER W/ HAND SINK DUKE MANUFACTURING DAI ( )RH ( X )W ( )CENTER HAND SINK._ )24" ( )36" ( X )48" ( )60" ( )72" LENGTH. STAINLESS STEEL TOP. FONT HILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 33 REFRIGERATED BACK COUNTER DUKE MANUFACTURING DAI 1 ( X )48" LENGTH. ( )60" LENGTH. BACK COUNTER WITH UNDER — COUNTER REFRIGERATOR. STAINLESS STEEL TOP. FONT HILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 34 RAPID COOK OVEN TURBOCHEFJMERRYCHEF DAI 1 (JTURBOCHEF ( )MERRYCHEF MICROWAVE /CONVECTION OVEN. REFER TO TUSCANY II BACK —UP SHEET #4 FOR FURTHER SPECIFICATIONS. BACKROOM AREA 36 SINK DUKE MANUFACTURING DAI G.C. 1 1 ( 3 )COMPARTMENT(S) ( 2 )DRAINBOARD(S). ( X )18" ( )24" DRAINBOARD SIZE. INSTALLED BY G.C. ULS APPROVED. FLOOR LEVEL SINK. 2' X 2' (PREFERRED). ACQUIRE LOCALLY. INSTALLED BY C.C. 37 MOP SINK LOCALLY SOURCED 38 HOT WATER TANK LOCALLY SOURCED G.C. 1 ACQUIRE LOCALLY. INSTALLED BY G.C. 39 S.S. WORKTABLE DUKE MANUFACTURING DAI 1 ( )24" ( )36" ( )48" ( J60" ( X )72" ( )84" ( )96" ( )108" ( )120" X 30 ". ( X )W/ GALVANIZED UNDERSHELF ( )WITHOUT UNDERSHELF. 40 WALL SHELF INTER METRO DAI 3 SUPER ERECTA BRITE. EPDXY COATED, WALL MOUNTED SHELVES. AVAILABLE IN VARIOUS SIZES. INSTALLED BY G.C. 41 VEGETABLE SINK DUKE MANUFACTURING DAI 1 ( 1 )COMPARTMENT(S) ( 1 )DRAINBOARD(S). ( X )18" ( )24" DRAINBOARD SIZE. INSTALLED BY G.C. ULS APPROVED. 42 HAND SINK DUKE MANUFACTURING / LOCAL DAI /G.C. 1 WALL MOUNTED, 10" X 14" X 6 ", OR SEE OWNER FOR SPECS. SUBJECT TO HEALTH CODE APPROVAL 43 CLEANING PRODUCT RACK SSDC DAI 1 DISPENSING STATION FOR CLEANING PRODUCTS. 45 NEMCO EASY — SLICER NEMCO, INC. DAI 1 MANUAL SLICER MOUNTED ON STAINLESS STEEL TABLE TOP. NSF APPROVED. 46 RETARDER CABINET LOCKWOOD DAI 1 ( X )WALK —IN ( )REACH —IN . NSF APPROVED. 47 REFRIGERATOR NORLAKE DAI 1 ( )8' X 6' ( )6' X 8' ( X )6' X 6' ( )5' X 6' ( )4' X 6' ( )3 DOOR ( )2 DOOR ( )1 DOOR ( )OTHER SELF— EVAPORATING. DIRECT WIRED. INSTALLED BY G.C. NSF APPROVED. 48 FREEZER NORLAKE DAI 1 ( )8' X 6' ( )6' X 6' ( X )6' X 6' ( )5' X 6' ( )4' X 6' ( )3 DOOR ( )2 DOOR ( )1 DOOR ( )OTHER SELF — EVAPORATING. DIRECT WIRED. INSTALLED BY G.C. NSF APPROVED. 49 STORAGE UNITS INTER METRO DAI •• � ( 1 )18" X 60" ( 3)24" X 72 ". SUPER ERECTA BRITE. 50 SODA STORAGE COKE DAI DEDICATED 115V, 20 AMP DUPLEX OUTLET (NEMA 5-20R) W/1N 3 FEET OF BIB RACK, 96 INCHES HIGH /WATER 1/2 INCH BALL VALVE SHUTOFF W /IN 3 FEET OF BIB RACK, 96 INCHES HIGH (EQUIPMENT INSTALLED BY COKE). RECEIVER AND AMPLIFIER WITH THREE SPEAKERS MOUNTED AND PROFESSIONALLY WIRED IN CEILING. OPTIONAL SUBWAY® RADIO SERVICE. 51 STEREO SYSTEM SUBWAY@ RADIO /LOCAL DAI /LOCAL 1 1 I 1 1 1 1111111 11111111111111111 1111111111111 111111111111/1U/, 1111111111111 11111111111111111 1111111111111 1 1 1 1 1111111111111 111111 1 1111 1 1 11111111111111111 1111111111111 11111111111111111111111111111111111I 11111111111111111 111111111111111 ►1111111111111111 11111111111111 IL 1111111111111111 11111111111111111n11111111111111111 51 98" C • A 6B I i II I II II II II �LJ 11 1 I / /// 0 0 0 6B, 12" • ABOVE #3 8 PANELS A,f 29 3c� MODEM LINE (REQUIRED) L.H. 31 20 L5 60" X42" I MOUNT ON SHELF II HEADERWALL ©6' -8" A.F.F ABOVE #38 1 O 11111111111111111 a 1111111 1l1Iul1l111M01111111111Il WALL t MOUN 111111111111111111111111111111111111 11111111111111111 1111111111DM " ' 1u uuiu111111 111111111111111 n11111111111111111 111111M1111u 11M1IIU111111111 x (4 6 •1 L _J 43 I� 174 DIRECT WIR 10' 9' -6" 17'— 2" TYP. EXISTING RESTROOM ENTRANCE 1 30 "X48" CLEAR SPACE REQUIRED J 3' -11" 3'0" X 6'8" L - 0 ( 0 TYP \) ICE ON] TOP C 11 ) C ri l C IxED cED cliDci IA ClicED CID w I :1) ) D 17' -6" x J a 20" 1, - ,144441 - 7 - 0" 42" OILING GATE 66' row e%tiet mied‘ piarcemoes4 "4 6 s 5 4t*e F 3 di c Dv* - cIO64' ?fmv.o(e+c(ts. 12' -7" 30'— 3" 36" HIGH WALL 21'— —10" „ 11' -8" I N N REV k::\NED FOR CODE COMPLIANCE APPROVED MAR 12 2009 City of Tukwila BUILDING DIVISION GENERAL NOTES.' RECEIV CITY of TU LA FEB Q 2 2009 PERMIT CENTER NEW LOCATION — CEILING HEIGHT IS 20' — ELECTRICAL OUTLET HEIGHTS MEASURED TO BOTTOM OF BOX. — ONE ELECTRICAL JUNCTION BOX TO BE LOCATED IN CEILING ABOVE EACH WINDOW. — STORE DESIGNED WITH CONTOUR SEATING. SHOWN ON PLAN AS SINGLES NOT GROUPS. — CUNO MODEL SW3 —PLUS WATER FILTRATION SYSTEM IS REQUIRED IN ALL NEW STORES THAT DISPENSE BEVERAGES. THE RECOMMENDED PLACEMENT FOR INSTALLATION IS MOUNTED TO SODA SYRUP RACK BY COCA —COLA. SECONDARY PLACEMENT OPTION IS MOUNTED ON THE BACKROOM WALL. THIRD INSTALLATION OPTION IS MOUNTING INSIDE THE FRONT BEVERAGE COUNTER WHEN SPACE LIMITATIONS OCCUR. REQUIRED: 1/2" INCOMING WATER LINE FEED WITH 1/2" BALL VALVE SHUTOFF AND 1/2" FPT CONNECTION. MINIMUM 110 VOLT, 20 AMP ELECTRICAL SERVICE TO SUPPORT THE CARBONATOR AND WATER BOOSTER (MUST BE DEDICATED CIRCUIT). — SMARTCURVE STAND (MFR. DISPLAY —BOX) REQUIRED IN CUSTOMER AREA AT POINT OF ORDER (PREFERRED PLACEMENT). 21 3/4" X 13 1/8" BASE, 56" (WITHOUT HEADER) OVERALL HEIGHT. — BASKET STYLE SECONDARY CHIP RACK REQUIRED IN CUSTOMER AREA AT POINT OF ORDER (PREFERRED PLACEMENT). — EXIT LIGHTS INSTALLED BY G.C. PER LOCAL CODE. — EMERGENCY LIGHTS INSTALLED BY G.C. PER LOCAL CODE. — EXTINGUISHERS, SMOKE AND FIRE DETECTION SYSTEMS INSTALLED BY G.C. PER LOCAL CODE. — LABOR & MATERIAL SUPPLIED BY G.C. UNLESS OTHERWISE NOTED. — ALL DIMENSIONS TO BE VERIFIED BY G.C. ON SITE. — DECOR SPECIFICATIONS ARE TO BE SUBWAY'S "TUSCANY II" SCHEME. — REFRIGERATOR AND FREEZER MUST BE ADEQUATELY VENTILATED. REFER TO MANUFACTURER FOR DETAILS. — THE D.A. MUST CONFIRM THAT SUBWAY WILL SHARE OR BE PROVIDED SPACE FOR THE FOLLOWING ITEMS: RESTROOM ACCESS. — VISIBILITY INTO BACKROOM THROUGH GLASS MUST BE OBSCURED. — EXISTING FLOOR FINISH TO REMAIN. — EXISTING CEILING AND FIXTURES TO REMAIN. STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ("DAI ") D /B /A SUBWAY. RECIPIENT MUST DETE R MINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND/OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAPS AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAI'S STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. CC w 0 CC SHEET #: lof 2 ©2008 DOCTORS ASSOCIATES, INC. STORE #42522 DEVELOPMENT AGENT: REVISION: W ALL *SEE (SEE TUSCANY II DECOR CALCULATIONS -- NOTE: THE SUBWAY STORE DESIGN DEPARTMENT CM,G ULATIONS PROVIDED BELOW MUST BE THESE M.ATERL4LS IS ACCEPTED :T PLACED. MANUFACTURER WILL NOT ACCEPT RESPONSIBILITY FOR ANY INACCURACIES ' THE VERIFIED BY THE G. C. AND FRANCHISE OWNER BEFORE ANY ORDER FOR C UANTITIES C ALCULATION WORKSHEET - CUSTOMER AREA -- Ti Y ARDS CITYSCAPE MURAL 2) 20 YARDS OF TUSCAN STUCCO WALL COVERING 3) 35 FE:ET OF UPPER DECORATIVE MOLDING 4) ( 50 FE:ET OF LOWER CHAIR RAIL MOLDING 5) ( 20 ) YAR OF QUENTIN WALLCOVERING (OR OPTIONAL BUTTERNUT BRICK WALLCOVERING) 6) ( - ) (OPTIONAL)FEET CIF HARDWOOD CROWN MOLDING (AT CORNER WHERE WALL AND CEILING MEET) 7) ( - ) FE:ET OF HARDWOOD CROWN MOLDING (FINISH CAP ON STRIP LIGHTING SHELF) 8) ( 18 ) YARDS OF RED WALL COVERING 1) M /rS + S/M + 10% DIVIDED BY 3. 2) M /TS + Vs + R /TS 10% DIVIDED BY 3 3) M /TS + S/M + 10% 4) M /TS + T, /S + R /TS 10% 5) (CEILING HEIGHT -- 7' -6 ") X (M/TS + S/M + (Q /WC OR B/T IN CUSTOMER AREA ONLY)) + 5% DIVIDED BY 12 6) M /TS + S/M + R/Ts (+ W /TS IF WINDOWS NOT TO CEILING) + 10 %. 7) TOTAL LENGTH OF WALLS WHERE FLUORESCENT STRIP LIGHTING TO BE INSTALLED + 10% 8) HEIGHT FROM TOP OF TUSCAN STUCCO WALL COVERING TO CEILING (36" A.F.F.) X Ft /TS + 5% DIVIDED BY 12 SERVICE AREA •y- 1 7-4, X 12' SHEETS FONT -HILL PEAR LAMINATE* 10) ( 2 ) 12' T- MOLDING STRIPS * 11) 37 ) YARDS OF BUTTERNUT BRICK TEXTURED WALL COVERING 12) t RIGHT ( 1 }LEFT VEGETABLE MOSAIC TILE 13) - ) (OPTIONAL) FEET OF COPPER CORNICE TRIM 9) FP /L + 5% DIVIDE:D BY 12 10) (FP /L ON 36" HIGH WALLS X 2) + (FP /L ON 48" HIGH WALLS X .3) + 5% DIVIDED BY 12 11) CEILING HEIGHT X B/T + 5% DIVIDED BY 12 13) TOTAL. LENGTH OF CUSTOMER SIDE OF HEADERWALL(S) OVER SERVICE AREA + 5 %. BACKROOM 14j( 227MARLITE F.R.P. WHITE (ALMOND OPTIONAL IF PERMITTED BY HEALTH /BUILDING CODE) 15 21 ) PVC DIVISION MOLDING 16) 7 ) PVC INSIDE CORNER 17) 0 ) PVC OUTSIDE CORNER 18) 6 ) PVC CAP MOLDING 14) W/R + 5% DIVIDED BY 4 15) PANEL COUNT FROM #14____._ LESS 1 16) COUNT ALL INSIDE CORNERS WHERE W/R MEET 17) COUNT ALL OUTSIDE CORNERS WHERE W/R MEET 18) COUNT ALL EDGES WHERE W/R BEGINS & ENDS & DOORWAYS. * CALCULATIONS ARE FOR FONT -HILL PEAR LAMINATE NND ALUMINUM T- MOLDING APPLIED TO 36" AND 413" HIGH WALLS. LAMINATE AND T- MOLDING, WHEN AFFIXED DIRECTLY TO DUKE FRONT COUNTER, IS SHIPPED READY TO INSTALL BY DUKE MANUFACTURING. NOTE: NEE :DE :D TO DECOR THE AREA ABOVE OR BELOW - rHE WINDOWS. : 17-ESE CALCULATIONS DO NOT INCLUDE THE MATERIALS NOTE: CALCULATIONS FOR WALL COVERING TO A HEIGHT OF 14'. AREA ABOVE 14' TO BE PAINTED WITH SHERWIN WILLIAMS SW6126 NAVAJO WHITE VINYL. WALLCOVERING (WITH LOWER CHAIR RAIL MOLDING) VINYL. WALLCOVERING REVISION: W ALL *SEE (SEE p INISJTI LPJGEAD (TUSCANY if DECOR) TUSCANY II BACK -UP SHEET I OF 4 AND 2 OF I FOR PEZOPER INSTALLATION OF WALLF'INISHES IN CUSTOMER AND SERVICE AREAS. TUSCANY SUPPLEMEN'T'AL 'PILE BACK -UP SHEET %SHEN APPLICABLE) SYMBOL DESCRIPTION MANUFACTURER SUPPLY INST. 6O/6I NOTES: (Z — ) SUBWAY MURAL SUNOCO FABRICS D.A.I. G.C. VINYL WALLCOVERING (TIPPER CIiMR RAIL MOLDING AND QUEN'UN OR BUTTERNUT BRICK WAU.COVERING AS REQUIRE TUSCAN STUCCO WALLCOVERING SUNGLO FABRICS D.A.I. G.C. G.C. VINYL. WALLCOVERING (WITH LOWER CHAIR RAIL MOLDING) VINYL. WALLCOVERING Ts (� RED WALL COVERING SUNGLO FABRICS D.A.I. TUSCAN STUCCO WALLCOVERING SUNGLO FABRICS D.A.L. D.A.I. G.C. C.C. VINYL. WALLCOVERING (WITH LOWER CHAIR RAIL MOLDING VINYL. WALLCOVERING ( BUTTERNUT BRICK WALL COVERING SUNGLO FABRICS (L CABINET /WALL LAMINATE WILSONART G.C. G.C. FONT —HILL PEAR (#10745-60) — INSTALL GRAIN HORIZONTALLY a' MOSAIC TILE (RIGHT) VACUFORM/ D.A.I. G.C. GRAPHIC IMAGES (SEE 45 TUSCANY TII BACK-UP SHEET FOR DETAILS AND OPTIONS) # PEAR BORDER AND 4" LIGHTED PURSE RAIL. e _ MOSAIC TILE (LEFT) VACUFORM/ WILSONART D . A . I . G. GRAPHIC IMAGES (SEE TUSCANY II BACK -UP SHEET FOR DETAILS AND •OPTIONS) WITH VVILSONART #10745 -60 FONTHILL PEAR BORDER AND 4" LIGHTED PURSE RAIL. (t WAALL CAPS . C.C. G.C. G.C. HARDWOOD PLANK (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SA TI NZ ( FRP OR PAINTED WALLS MARLITE /G.C. DAI /GC (,.L. WHITE FRP PANELS OR OFF —WHITE SEMI —GLOS PAINT (A`) FP OLY ER P REI AN FORCED FRP MARLITE D.A.I. C.C. ....0 & LOWER FRP PANELS — WATER RESISTANT COVERING. WHITE OR *ALMOND + ALMOND OPTION ONLY IF PERMITTED BY HEALTH /BUILDING CODE) NOTE: ALL WOOD INTERIOR DOORS, UPPER W,/ MINWAX #235 CHERRY AND POLYURETHANED MOLDING & CROWN WN MOLDING TO BE STAINED NV _MINWAX FAST DRYING CLEAR SATIN. NOTE: FREFINISHED AND PREFRAMED COUNTER ENTRANCE GLUE 2 PIECES OF 5/8" PARTICLE BOARD TOGETHER. F CR FINISH OPTIONS. IS AVAILABLE THROUGH PLYMOLD OR SEE TUSCANY II BACK —UP SHEET #1 NOTE: F.R.P. SHOULD BE TO CEILING HEIGHT IN BACKROOlv1, ABOVE FINISHED FLOOR. F.R.P. IN RESTROOMS BUT MUST BE A MINIMUM OF 8' - -O" MUST BE FLOOR TO CEILING. REVISION: 1 A8 31va UPGRADE TO 'TUSCANY lP' awd 9OI Z/cc DECOR CHANGES awd I 6O/6I -a 11111111111.11=11.111•11 411•0111■11 lesommenouraws MOM EXISTING DECOR TO REMAIN EXISTING DECOR TO REMAIN EXISTING DECOR TO REMAIN L� / 6 5ON FRONT } AND BOTTOM 17 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 12 2009 GENERAL NOTES: -a y CITY OF TUKWILA FEB 0'2 2009 City of Tukwila PERMIT CENTER BUILDING DIVISION N!'1J WI OCA TION -- CEILING HEIGHT IS 20' -- ELECTRICAL OUTLET HE:IGHTS MEASURED TO BOTTOM OF BOX. - - ONE ELECTRICAL JUNCTION BOX TO BE LOCATED IN CEILING ABOVE EACH WINDOW. -- STORE DESIGNED WITH CONTOUR SEATING. SHOWN ON PLAN AS SINGLES NOT GROUPS. - CUNO MODEL SW3 -PLUS WATER FILTRATION SYSTEM IS REQUIRED IN ALL NEW STORES THAT DISPENSE BEVERAGES. THE RECOMMENDED PLACEMENT FOR INSTALLATION IS MOUNTED TO SODA SYRUP RACK BY COCA - -COLA. SECONDARY PLACEMENT OPTION IS MOUNTED ON THE BACKROOM WALL. THIRD INSTALLATION OPTION IS MOUNTING INSIDE THE FRONT BEVERAGE COUNTER WHE:N SPACE LIMITATIONS OCCUR. REQUIRED: 1/2" INCOMING WATER LINE FEED WITH 1/2" BALL VALVE SHUTOFF AND 1/2" FPT CONNECTION. MINIMUM 110 VOLT, 20 AMP ELECTRICAL SERVICE TO SUPPORT THE CARE]ONATOR AND WATER BOOSTER (MUST BE DEDICATED CIRCUIT). SMARTCURVE STAND (MFR. DISPLAY -BOX) REQUIRED IN CUSTOMER AREA AT POINT OF ORDER (PREFERRED PLACEMENT). 21 3/4" X 13 1/8" BASE, 56" (WITHOUT HEADER) OVERALL HEIGHT. -- BASKET STYLE SECONDARY CHIP RACK REQUIRED IN CUSTOME:R AREA AT POINT OF ORDER (PREFERRED PLACEMENT). -- EXIT LIGHTS INSTALLED BY G.C. PER LOCAL CODE. -- EMERGENCY LIGHTS INSTALLED BY G.C. PER LOCAL CODE. -- EXTINGUISHERS, SMOKE AND FIRE DETECTION SYSTEMS INSTALLED BY G.C. PER LOCAL CODE:. -- LABOR & MATERIAL SUPPLIED BY G.C. UNLESS OTHERWISE NOTED. -- ALL DIMENSIONS TO BE VERIFIED BY G.C. ON SITE:. -- DECOR SPECIFICATIONS ARE TO BE SUBWAY'S "TUSCANY II" SCHEME. -- REFRIGERATOR AND FREEZER MUST BE ADEQUATELY VENTILATED. REFER TO MANUFACTURER FOR DETAILS. -- THE U.A. MUST CONFIRM THAT SUBWAY WILL SHARE OR BE PROVIDED SPACE FOR THE FOLLOWING ITEMS: RESTROOM ACCESS. - VISIBILITY INTO BACKROOM THROUGH GLASS MUST BE OBSCURED. -- EXISTING FLOOR FINISH TO REMAIN. -- EXISTING CEILING AND FIXTURES TO REMAIN. INN INN M STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. MEM THIS DRAWING IS FURNISHED BY MOTORS ASSOCIATES INC. ( "DAI'; D /B /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE DR _OCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR .AND/OR FRANCHISEFJOWNER. ANY 7ISCREPANICY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAPS AREA DEVELOPMENT AGENT CR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB- CONTRACTOR SHALL MA<E HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAI'S STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL. PROPERTY OF SLBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS, RECIPIENT AGREES NOT - O REPRODUCE, COPY, USE OR TRANSMIT TE-IS DRAWING AND /OR TS NFORMATIONAL ODNTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. stommonisaraimmomponn mama. czC -a SHEET #: 2 62008 DOCTORS ASSOCIATES, INC. ct cr eL DATE: JA NUARY 7, 2008 DESIGNED BY: PETER SELLEY1 DAVE SURA DRAWN BY: REV BY: PMD SCALE: 1/4" = 1'4'' DEVELOPMENT AGENT: REVISION: A8 FT ..• • :' •0.: d :• . • • •1 P • • • ,••• y •s.. •, ' .• • • ...P.'. . • .. . .:::•:• • '• •1••. . • •• • •• •••• • W•'' •• y ••• •,:, :' '•• 7• i• • •• •• r �•• • • 1 I• : •••� • ...• . •{••' : 1. : ••• • . • , ,... :. •:.... :•'..,-, . : :::• • • .f� ti :• ' l WALL ART /PRINT WALL ART PRINT , ... / i 1 1 1 1 1 1 1 1 1 11 1 REVISION: A8 FT 54" SLICING PIT WALL & ADDED SOAP DISPENSERS elwd WALL ART PRINT/ lf . l WALL ART /PRINT WALL ART PRINT WALL ART PRINT / j 1 �'„+. '11I ' 6' (MINIMUM) [182.9cm] [182.9cm] DATE: 10 -31 -08 DESIGNED BY: PATRICK ROSE DRAWN BY: PMR REVIEWED BY: PMR SCALE: NOT TO SCALE 1" X 2" SHELF BRACE IN BETWEEN FIXTURES LIGHT FIXTURE CROWN MOLDING 1 "X4 "SHE OPTIONAL: UPPER WALL LIGHTING STRIP SURFACE FLUORESCENT FIXTURES. MANUFACTURER: NORA LIGHTING. MODEL#: NULS -28 4' LONG)(F28T5 BULB NULS -21 3' LONG)(F21T5 BULB UP TO (10 NULS -28 AND /OR NULS -21 FIXTURES MAY BE CONNECTED TO SINGLE 120V POWER CORD FEED. PLACED ABOVE UPPER DECORATIVE TRIM (NOT OVER WINDOWS). MOUNT ON 1" X 4" SHELF WITH 4 1/2" CROWN MOLDING (BY HOUSE OF FARA TO HIDE FIXTURES (SHELF AND MOLDING TO BE STAINED 2 COATS MINWAX #235 CHERRY AND POLY - URETHANED WITH MINWAX FAST DRYING SATIN) (D SECTION VIEW SIDE WALL 1" X 2 1/2" BLOCK 0 0 Oi N N CUSTOMER AREA WALL ELEVATION(TYPICAL) (SEE GENERAL NOTES 1, 2 & 5) OPTIONAL: 4 1/2" HARDWOOD CROWN MOLDING (MINIMUM 8'- 6 "[259.1cm] CEIILING B UTTERNUT BRICK HEIGHT REQUIRED FOR THIS OPTION) ALL COVERING _I N L_JI it I L-JI L J L-JL I L -II 1L L�JI L I ■■■ = L_J J TE -- am i 1�■ LT 1 r �■I r MOM r i �ri�t�i■r =■ ■_lid il■ =� ■_iSri�l�i■■■ i� i'■�irl_iI■ OPTIONAL: 4 1/2" HARDWOOD CROWN MOLDING (MINIMUM 8' -6 "[259.1 cm] CEIILING HEIGHT REQUIRED FOR THIS OPTION) SIDE BACK COUNTERS PAPER WALL SIDES AND DOORS: FONT HILL PEAR TOWEL SOAP - LAMINATE (WILSONART #10745 -60) DISPENSER DISPENSER HAND (INSTALL GRAIN HORIZONTALLY) (REQUIRED) (REQUIRED) DISPENSER TOP: STAINLESS STEEL (OPTIONAL) I f 1 SIDE TUSCAN STUCCO / WALL WALL COVERING BACK COUNTERS J COVE BASE OR BULLNOSE • ALL NEW DUKE FRONT COUNTERS ARE SHIPPED WITH PREFABRICATED DECOR PANELS READY TO INSTALL. •PREFABRICATED DECOR PANELS ARE AVAILABLE READY TO INSTALL FOR SITE BUILT 36" AND 48" HIGH SERVICE AREA WALLS AND ARE MADE TO ORDER. •ALSO AVAILABLE FROM DUKE MANUFACTURING ARE PREBUILT, PREFINISHED MADE TO ORDER 36" AND 48" HIGH SERVICE AREA SIDE AND FRONT WALLS WITH OR WITHOUT PREFINISHED COUNTER ENTRANCE GATE. •PREFABRICATED DECOR PANELS ARE AVAILABLE FOR EXISTING FRONT COUNTERS AS WELL. COUNTER ENTRANCE FINISH OPTIONS: OPTION #1 (PREFERRED) PREFINISHED & PREFRAMED COUNTER ENTRANCE GATE AVAILBALE THROUGH PLYMOLD AND DUKE MANUFACTURING. OPTION #2 GLUE TOGETHER 2 PIECES OF 5/8" PARTICLE BOARD AND FINISH WITH WILSONART #10745 -60 FONTHILL PEAR LAMINATE. EDGE WITH 1 1/2" HARDWOOD MOLDING (STAINED WITH MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN). SECURE WITH HEAVY DUTY HINGES AND INSTALL A BAR LATCH ON THE EMPLOYEE SIDE. 7- OPTIONAL: 4 1/2" HARDWOOD CROWN MOLDING (MINIMUM 8'- 6 "[259.1cm] CEIILING HEIGHT REQUIRED FOR THIS OPTION) OPTION 1) QUENTIN WALLCOVERING OPTION 2) BUTTERNUT BRICK WALLCOVERING. I I I SIDES AND DOORS: FONT HILL PEAR LAMINATE (WILSONART #10745 -60) (INSTALL GRAIN HORIZONTALLY) TOP: STAINLESS STEEL FONTHILL PEAR LAMINATE (WILSONART #10745 -60) W /MILLED ALUMINUM TEE MOLDING � COVEBASE OR-1 BULLNOSE 5/8" DRYWALL 2" X 4" WOOD OR METAL FRAMING OPTION 1) QUENTIN WALLCOVERING OPTION 2) BUTTERNUT BRICK WALLCOVERING. UPPER 1 1/2" DECORATIVE TRIM MOLDING EMPIRE TRIM - 9" (UPPER PORTION OF MAIZE TONE CITYSCAPE MURAL) 12' ALTERNATING MAIZE TONE CITYSCAPE MURAL PANELS, A & B LOWER 2 1/2" CHAIR RAIL MOLDING TUSCAN STUCCO WALL COVERING (CONTINUOUS ROLL) COVE BASE OR BULLNOSE T OPTION 1) QUENTIN WALLCOVERING OPTION 2) BUTTERNUT BRICK WALLCOVERING. .; m oi am • ` M.= I��L��1� � MMII. 1�■ �1� �1��1���1��1■• �1� ■�I��l■1�■�I■t�l■�R�� r ■■,�� �■�■■� sus �■� �° �, 1r�1�■ �■■l� ■s�■1■ �■((� r a m ■r •■w■■�wml■�■_1 l ■-1�_ ' _1 ir ■■■ ss�■r■■�■s -_Ii MI - 1_�i� ■l is ow or sr sr sr ■�• ■r MANN MOM oo ■ 1 r �`s ' l � s war or ow on IN rr■r■■■ I r ■.r�nlss■■rlllsl�ss.■.rr i 71. ._J .rrr� �� � � � l■rw rr■.■1s r■S■I.r�s 1■IrM�■1al■s� � -I r■ I ' sr �a..C�o■ r L M `c� r c� r s■_ -I ale � r � r rr ■ :■��I , L WI ri�r�� El ■ "! r row - - BREAD Ir. : BRI EAD : i7 ros _CABINET Ini ' - BAKING : II. s■s■■NC�C�■ - --■ 1140101 ■ - _ OVEN - LI - rim r[r■■ r - PE , IN was ro 1T lI11al- �,t■�■T.IAIM MP= MENUBOARD UPPER 1 1/2" DECORATIVE TRIM MOLDING --- TONE CITYSCAPE MURAL LOWER 2 1/2" CHAIR - RAIL MOLDING CUSTOMER SI \ a cNI N M TUSCAN STUCCO WALL COVERING -COVE BASE OR BULLNOSE PAPER TOWEL DISPENSER (REQUIR.ED) SOAP DISPENSER (REQUIRED) FONTHILL PEAR LAMINATE ( WILSONART #10745 -60) SANITARY COVE BASE (IF REQUIRED BY LOCAL HEALTH) " ' [15.62cm] EMPLOYEE SIDE 0 N, If 0) in I SERVICE AREA - SIDE FACING ELEVATION (TYPICAL) (SEE GENERAL NOTES 1, 2, 3 & 5) UPPER 1 1/2" DECORATIVE TRIM MOLDING MAIZE TONE CITYSCAPE MURAL LOWER 2 1/2" CHAIR > s1�.■,wl� ■r��i ( l�.■ �■ i ris, .11 I�I ■rrus■. �__,�1r L- s■Ir!I 1011111111100 1 I . s■r1 -' r+l■ ii■Is.�J- - Islrlr(�s�slrlslr - 1-0 -4 ".■1■F■■wl 11- ' �I mit � �w-- 1�"�r''rrrrrrrr� ��■t- Lr"r�i1�' I� • I -- iss 1•11 1•11 ■I I 0_91 rl a a¢ f a i o C il NI OP NM I I - BREAD i BREAD - ill - BAKING : 'I IIA _CABINET (: OVEN - !� 1 al MENUBOARD / \V\ 1� BUTTERNUT BRICK + WALL COVERING JI L "15 I J L ._ Jl f iL I 1•111101111111110 mi l_ 1•0111A 01111011111110101•111111111111 01•10111111111111110111011 IMO ■r.� MINN •1• r(�i 1000 ■ r■ r1■■Ir _r■ I■�■1 �1r■ was, 1 �s,�las■ rural COUNTER TOP 1" X 12" HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) U N N, u HAND SANITIZER DISPENSER (OPTIONAL) SERVICE AREA - FRONT FACING ELEVATION (TYPICAL) (SEE GENERAL NOTES 1, 2, 3 & 5) ao CUSTOMER AREA "RED" WALL ELEVATION(OPTIONAL) (SEE GENERAL NOTES 1, 2 & 5) 0 0 0i N N u U rn N I--' w _ z J W 0 u I- _ 0 w x 0 z J w 0 SIDE WALL SIDE WALL E 0 N Fri 0 N I cv M a E 0 M I; rn 3/4" MILLED ALUMINUM FONTHILL PEAR T- MOLDING #ALU -1028 LAMINATE (TYP) VC SUPPLIED BY (WILSONART OUTWATER PLASTIC #10745 -60) INDUSTRIES INC. INSTALL GRAIN SIDE VIEW HORIZONTALLY (SHOWN WITH COUNTER ENTRANCE AND BUILT SOFFIT WALL OPTION) FRAMED AND DRYWALLED SOFFIT ABOVE FRONT AND SIDE OF SERVICE AREA. FINISH OPTIONS: 1) QUENTIN WALLCOVERING. 2) BUTTERNUT BRICK WALLCOVERING. 3) FONT HILL PEAR LAMINATE (WILSONART #10745 -60) 4) BLONDE PAINT (SHERWIN WILLIAMS SW6128) 5) FIRED BRICK RED PAINT (SHERWIN WILLAMS SW6335) IN1NI1UPAIJU0V11 )l•1.0.V_leNIP FIIF NO:l•IbF:e!NI Gig *FPJ• l!L,MP COUNTER TOP HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) 3/4" MILLED ALUMINUM T- MOLDING #ALU -1028 VC SUPPLIED BY OUTWATER PLASTIC INDUSTRIES INC. OPTIONAL: 4 1/2" HARDWOOD CROWN MOLDING (MINIMUM 8'- 6 "[259.1cm] CEIILING HEIGHT REQUIRED FOR THIS OPTION) 4" WIDE PURSE RAIL WITH LIGHTS AND FONTHILL PEAR FINISH M E rn COVEBASE OR BULLNOSE RED WALL COVERING (REFER TO FLOOR PLAN FOR EXACT PLACEMENT) NOTE: NO UPPER DECORATIVE MOLDING INSTALLED FOR ENTIRE NS SECTION OF RED WALL COVERING. LOWER 2 1/2" CHAIR RAIL MOLDING TUSCAN STUCCO WALL COVERING (CONTINUOUS ROLL) COVE BASE OR BULLNOSE z J w 0 io CD �II IIIIIIII I MOSAIC TILE PATTERN* (PANEL "A ") FRONT SERVICE COUNTER ELEVATION (TYPICAL) (SEE GENERAL NOTES 1, 2, 4 & 6) NOTE: AREA BELOW HARDWOOD PLANK TO BE FINISHED WITH LOWER CHAIR RAIL MOULDING (STAINED MINWAX #235 CHERRY AND POLYRETHANED WITH MINWAX FAST DRYING CLEAR SATIN) TUSCAN STUCCO - WALL COVERING (CONTINUOUS ROLL) JA #587 -1 COVE BASE OR BULLNOSE SUPPLIER - HOUSE OF FARA DEE - HARDWOOD FINISH - STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN. FRONT SUPPLIER -- HOUSE OF FARA TYPE - HARDWOOD FINISH - STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN. OPTIONAL: WITH FRAMED AND DRYWALLED SOFFIT ONLY. COPPER CORNICE TRIM WITH 3 1/2" PROJECTION (CHICAGO METALLIC #63.40,035 TO ORDER CALL 1- 800 - 323 -7164) III MOSAIC TILE PATTERN* (PANEL "B ") FRONT 2' -0" 60.9cm OPENING FOR FRONT LINE BREAD CABINET (OPTIONAL) FRONT VIEW (SHOWN WITH BUILT SOFFIT WALL OPTION. *CEILING MUST BE MIN. 9' -0" TO USE THIS OPTION) 1" X 8" HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) 8" [20.3cm] 4' 4' SEATING DIVIDER WALL (TYPICAL) (SEE GENERAL NOTES 1 & 2) SQUARE; FRAMED WALL ART NOTES: •EIGHT DIFFERENT PRINTS AVAILABLE (SHOWN ABOVE). CAN BE ORDERED INDIVIDUALLY OR IN SETS. •COLOR PHOTOGRAPHS DOUBLE MATTED. •BLACK WOODEN FRAME WITH PLEXIGLAS. •MOUNTED TO WALL USING HANGING /SECURITY HARDWARE (SUPPLIED WITH EACH WALL ART PIECE). • DIM. 26 "W X 26 "H X 1" DEEP •HUNG ON WALL BETWEEN UPPER AND LOWER CHAIR RAIL MOLDING. REFER TO FLOOR PLAN FOR EXACT PLACEMENT. WALL ART - SQAURE HARDWOOD CROWN MOLDING LOWER CHAIR RAIL MOLDING IIIIIIIIII COVEBASE OR BULLNOSE MOSAIC TILE PATTERN TO BE FRAMED WITH FONTHILL PEAR LAMINATE (WILSONART #10745 -60) PROFILE III 0 , ...mlom vvmnra vl•Ivmmwwox mm!vmmly iii •IL•.vivo,.vv!mmla.vvvwommry mmmlvm ,vmmlv,mlvmmmwemmmw 4" WIDE PURSE RAIL WITH LIGHTS AND FONTHILL PEAR FINISH FONTHILL PEAR LAMINATE (TYP) (WILSON ART #10745 -60) INSTALL GRAIN HORIZONTALLY 3/4" MILLED ALUMINUM T- MOLDING #ALU -1028 VC SUPPLIED BY OUTWATER PLASTIC INDUSTRIES INC. *NOTE: FOR A MORE PRIVATE AND /OR UPSCALE APPEARANCE THE INSTALLATION OF GLASS BLOCK OR ETCHED GLASS DIVIDERS MAY BE INSTALLED ON TOP OF THE 1" X 8" HARDWOOD PLANK. COVEBASE BULLNOSE #102 -1 TUSCAN STUCCO \ WALL COVERING COVE BASE OR BULLNOSE 5/8" DRYWALL 2" X 4" WOOD OR METAL FRAMING 012 SUPPLIER - CHICAGO METALLIC FINISH - COPPER 3 1/2" PROJECTION CONVEX FACE #63.40.035 gag COPPER CORNICE TRIM MOLDINGS (OPTIONAL) w LI.I a w \ FRONT UPPER DECORATIVE TRIM MOLDING FRONT MOLDINGS (REQUIRED) COUNTER TOP HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) \ 1" X 4" HARDWOOD SOFFIT (MOUNTED VERTICALLY) ABOVE FRONT AND SIDE OF SERVICE AREA. STAIN MINWAX #235 CHERRY AND POLYURETHANE WITH MINWAX FAST DRYING CLEAR SATIN. I I'IIIIIIIIIII OR 3/4" MILLED ALUMINUM T- MOLDING #ALU -1028 VC SUPPLIED BY OUTWATER PLASTIC INDUSTRIES INC. SIDE VIEW (SHOWN WITHOUT COUNTER ENTRANCE AND 1" X 4" OR 4" X 4" SOFFIT OPTION) UPPER :DECORATIVE TRIM 12" [30.5cm] TYPICAL VERTICAL WALL ART NOTES: •EIGHT DIFFERENT PRINTS AVAILABLE (SHOWN LEFT). CAN BE ORDERED INDIVIDUALLY OR IN SETS, •GRAPHICS PRINTED ONTO STYRENE FACED FOAM BOARD. •BLACK ALUMINUM FRAME. •MOUNTED TO WALL USING HANGING /SECURITY HARDWARE (SUPPLIED WITH EACH WALL ART PIECE). •DIM. 22 3/4 "W X 49 3/4 "H X 1" DEEP. •HUNG ON WALL BETWEEN UPPER AND LOWER CHAIR RAIL MOLDING. TYPICAL MOUNTING SHOWN BELOW. REFER TO FLOOR PLAN FOR EXACT PLACEMENT. NOTE: CAN NOT BE USED ABOVE BANQUETTE WALL BENCH SEATING. WALL PLANT MOUNTING BRACKET TO BE MOUNTED 15" [38.1cm] BELOW THE TOP OF THE UPPER DECORATIVE TRIM. TYPICAL LOWER CHAIR RAIL MOLDING GROUPS OF THREE PRINTS 12" [30.5cm] TYPICAL GROUPS OF TWO PRINTS PANEL "A" (LEFT SIDE) NOTES: 1.) GRAPHIC IMAGES TO BE PRINTED ONTO PANELS AND VACUUM FORMED TO CREATE THE APPEARANCE OF 4 1/4" X 4 1/4" CERAMIC TILES WITH 1/16" GROUT JOINTS. 2.) FOR CONVENIENCE THE FRAMED VACUFORM TILE AND LAMINATES CAN BE ORDERED FOR BOTH NEW AND REIIODELING LOCATIONS A LA CARTE FROM DUKE MANUFACTURING. ALL FRONT COUNTER UNITS ARE SHIPPED WITH A COMPREHENSIVE INSTALLATION GUIDE, FROM THE MANUFACTURER, ON THE ENTIRE PROCESS, FROM COUNTER SET -UP TO DECOR INSTALLATION. PROFILE SIDE WALL FONTHILL PEAR LAMINATE (TYP) (WILSON ART #10745 -60) INSTALL GRAIN HORIZONTALLY WITH CITYSCAPE MURAL WALL PLANT MOUNTING BRACKET TO BE MOUNTED 15" [38.1cm] BELOW THE TOP OF THE UPPER DECORATIVE TRIM. TYPICAL CITYSCAPE MURAL "- -LOWER CHAIR RAIL MOLDING WALL ART - VERTICAL PANEL "B" (RIGHT SIDE) MOSAIC TILE PATTERNS GENERAL NOTES: 1. ALL. HORIZONTAL DIMENSIONS ARE AS PER FLOOR PLANS UNLESS OTHERWISE NOTED. 2. BULLNOSE TO BE USED WHEREVER PORCELAIN FLOOR TILE IS USED UNLESS LOCAL HEALTH REQUIRES A SANITARY COVE BASE. 3. STORES WITH CEILING HEIGHTS OF 8' -8" [264.2cm] OR GREATER MAY INSTALL THE MENUBOARD OVER THE OVEN. REFER TO PLANS FOR EXACT PLACEMENT. FOR LOWER CEILING HEIGHTS REFER TO FLOOR PLANS FOR ALTERNATE MENUBOARD PLACEMENT. 4. FOR LOCATIONS WITH NEW DUKE FRONT COUNTERS, THE FINISH MATERIALS FOR THE FRONT FACE OF THE UNIT (MOSAIC TILE PATTERNS(S) WITH FONTHILL PEAR FRAMING WITH 3/4" T- MOLDING) ARE SHIPPED WITH THE COUNTER PREFABRICATED AND READY TO INSTALL. THIS APPLIES ONLY IF THE MATERIALS ARE TO BE INSTALLED DIRECTLY ONTO THE FRONT OF THE UNIT. PREFABRICATED AND FINISHED 36" AND 48" SERVICE AREA SIDE WALLS AND COUNTER ENTRANCE GATES ARE ALSO AVAILABLE FROM DUKE MANUFACTURING. 5. SEE CHAIR RAIL MOLDING DETAIL (THIS PAGE) FOR STYLE, FINISH AND PROPER PLACEMENT. 6. ALTERNATE COUNTER SIZES MAY VARY MOSAIC TILE PATTERN PLACEMENT. PLEASE REFER TO DRAWING FOR EXACT PLACEMENT. SUNGLO CITYSCAPE MURAL FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE SUNGLO TUSCAN STUCCO WALL COVERING FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE SUNGLO BUTTERNUT BRICK WALL COVERING FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE SUNGLO QUENTIN WALL COVERING FLAME SPREAD INDEX FUE: CONTRIBUTED VALUE SMOKE DEVELOPED VALUE SUNGLO RED WALL COVERING FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE WILSONART LAMINATE (G.P.) FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE MARLITE FIBERGLASS REINFORCED PANELS FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE VACUFORM MOSAIC TILE: PHYSICAL PROPERTY EIRE RATINGS DRYWALL UNBONDED 10 0 5 15 5 10 15 5 20 10 0 5 15 0 20 200 0 450 HEAT DEFLECTION TEMP (ANNEALED) ©264 PSI FLAMMABILITY RATING UNDERWRITERS LAB REVI5.WI CODE CON MAR 1 2 CNI BUILDING STRESS 55 0 30 FIRE AND EXPLOSION HAZARD DATA FLASH POINT: 425•F, 218 a (COC) AUTOIGNITION TEMPERATURE. NO DATA FLAMMABLE LIMITS (STP): NO DATA UPPER DECORATIVE TRIM WOOD PARTICLE BOARD D FOR PLIANCE If 2009 ukwffa )IVIS CITY OF TUKWILA FEB 0 2 ?IIII.y PERMIT CENTER TYPE 107 80 0 95 TYPE 335 TYPE 350 70 65 0 0 135 105 TEST METHOD ASTM D -648 UL 94 V -0 UNITS DEGREES F TYPICAL VALUES 155 PASSES STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ("DAI ") D /B /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND /OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAPS AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAPS STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. 1 SHEET #: 1 of 4 ©2008 DOCTORS ASSOCIATES, INC. / WALL ART PRINT A WALL ART PRINT I,/ 6' '(MINIMUM) WALL ART PRINT/ lf . l WALL ART /PRINT WALL ART PRINT WALL ART PRINT / j 1 �'„+. '11I ' 6' (MINIMUM) [182.9cm] 1" X 2" SHELF BRACE IN BETWEEN FIXTURES LIGHT FIXTURE CROWN MOLDING 1 "X4 "SHE OPTIONAL: UPPER WALL LIGHTING STRIP SURFACE FLUORESCENT FIXTURES. MANUFACTURER: NORA LIGHTING. MODEL#: NULS -28 4' LONG)(F28T5 BULB NULS -21 3' LONG)(F21T5 BULB UP TO (10 NULS -28 AND /OR NULS -21 FIXTURES MAY BE CONNECTED TO SINGLE 120V POWER CORD FEED. PLACED ABOVE UPPER DECORATIVE TRIM (NOT OVER WINDOWS). MOUNT ON 1" X 4" SHELF WITH 4 1/2" CROWN MOLDING (BY HOUSE OF FARA TO HIDE FIXTURES (SHELF AND MOLDING TO BE STAINED 2 COATS MINWAX #235 CHERRY AND POLY - URETHANED WITH MINWAX FAST DRYING SATIN) (D SECTION VIEW SIDE WALL 1" X 2 1/2" BLOCK 0 0 Oi N N CUSTOMER AREA WALL ELEVATION(TYPICAL) (SEE GENERAL NOTES 1, 2 & 5) OPTIONAL: 4 1/2" HARDWOOD CROWN MOLDING (MINIMUM 8'- 6 "[259.1cm] CEIILING B UTTERNUT BRICK HEIGHT REQUIRED FOR THIS OPTION) ALL COVERING _I N L_JI it I L-JI L J L-JL I L -II 1L L�JI L I ■■■ = L_J J TE -- am i 1�■ LT 1 r �■I r MOM r i �ri�t�i■r =■ ■_lid il■ =� ■_iSri�l�i■■■ i� i'■�irl_iI■ OPTIONAL: 4 1/2" HARDWOOD CROWN MOLDING (MINIMUM 8' -6 "[259.1 cm] CEIILING HEIGHT REQUIRED FOR THIS OPTION) SIDE BACK COUNTERS PAPER WALL SIDES AND DOORS: FONT HILL PEAR TOWEL SOAP - LAMINATE (WILSONART #10745 -60) DISPENSER DISPENSER HAND (INSTALL GRAIN HORIZONTALLY) (REQUIRED) (REQUIRED) DISPENSER TOP: STAINLESS STEEL (OPTIONAL) I f 1 SIDE TUSCAN STUCCO / WALL WALL COVERING BACK COUNTERS J COVE BASE OR BULLNOSE • ALL NEW DUKE FRONT COUNTERS ARE SHIPPED WITH PREFABRICATED DECOR PANELS READY TO INSTALL. •PREFABRICATED DECOR PANELS ARE AVAILABLE READY TO INSTALL FOR SITE BUILT 36" AND 48" HIGH SERVICE AREA WALLS AND ARE MADE TO ORDER. •ALSO AVAILABLE FROM DUKE MANUFACTURING ARE PREBUILT, PREFINISHED MADE TO ORDER 36" AND 48" HIGH SERVICE AREA SIDE AND FRONT WALLS WITH OR WITHOUT PREFINISHED COUNTER ENTRANCE GATE. •PREFABRICATED DECOR PANELS ARE AVAILABLE FOR EXISTING FRONT COUNTERS AS WELL. COUNTER ENTRANCE FINISH OPTIONS: OPTION #1 (PREFERRED) PREFINISHED & PREFRAMED COUNTER ENTRANCE GATE AVAILBALE THROUGH PLYMOLD AND DUKE MANUFACTURING. OPTION #2 GLUE TOGETHER 2 PIECES OF 5/8" PARTICLE BOARD AND FINISH WITH WILSONART #10745 -60 FONTHILL PEAR LAMINATE. EDGE WITH 1 1/2" HARDWOOD MOLDING (STAINED WITH MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN). SECURE WITH HEAVY DUTY HINGES AND INSTALL A BAR LATCH ON THE EMPLOYEE SIDE. 7- OPTIONAL: 4 1/2" HARDWOOD CROWN MOLDING (MINIMUM 8'- 6 "[259.1cm] CEIILING HEIGHT REQUIRED FOR THIS OPTION) OPTION 1) QUENTIN WALLCOVERING OPTION 2) BUTTERNUT BRICK WALLCOVERING. I I I SIDES AND DOORS: FONT HILL PEAR LAMINATE (WILSONART #10745 -60) (INSTALL GRAIN HORIZONTALLY) TOP: STAINLESS STEEL FONTHILL PEAR LAMINATE (WILSONART #10745 -60) W /MILLED ALUMINUM TEE MOLDING � COVEBASE OR-1 BULLNOSE 5/8" DRYWALL 2" X 4" WOOD OR METAL FRAMING OPTION 1) QUENTIN WALLCOVERING OPTION 2) BUTTERNUT BRICK WALLCOVERING. UPPER 1 1/2" DECORATIVE TRIM MOLDING EMPIRE TRIM - 9" (UPPER PORTION OF MAIZE TONE CITYSCAPE MURAL) 12' ALTERNATING MAIZE TONE CITYSCAPE MURAL PANELS, A & B LOWER 2 1/2" CHAIR RAIL MOLDING TUSCAN STUCCO WALL COVERING (CONTINUOUS ROLL) COVE BASE OR BULLNOSE T OPTION 1) QUENTIN WALLCOVERING OPTION 2) BUTTERNUT BRICK WALLCOVERING. .; m oi am • ` M.= I��L��1� � MMII. 1�■ �1� �1��1���1��1■• �1� ■�I��l■1�■�I■t�l■�R�� r ■■,�� �■�■■� sus �■� �° �, 1r�1�■ �■■l� ■s�■1■ �■((� r a m ■r •■w■■�wml■�■_1 l ■-1�_ ' _1 ir ■■■ ss�■r■■�■s -_Ii MI - 1_�i� ■l is ow or sr sr sr ■�• ■r MANN MOM oo ■ 1 r �`s ' l � s war or ow on IN rr■r■■■ I r ■.r�nlss■■rlllsl�ss.■.rr i 71. ._J .rrr� �� � � � l■rw rr■.■1s r■S■I.r�s 1■IrM�■1al■s� � -I r■ I ' sr �a..C�o■ r L M `c� r c� r s■_ -I ale � r � r rr ■ :■��I , L WI ri�r�� El ■ "! r row - - BREAD Ir. : BRI EAD : i7 ros _CABINET Ini ' - BAKING : II. s■s■■NC�C�■ - --■ 1140101 ■ - _ OVEN - LI - rim r[r■■ r - PE , IN was ro 1T lI11al- �,t■�■T.IAIM MP= MENUBOARD UPPER 1 1/2" DECORATIVE TRIM MOLDING --- TONE CITYSCAPE MURAL LOWER 2 1/2" CHAIR - RAIL MOLDING CUSTOMER SI \ a cNI N M TUSCAN STUCCO WALL COVERING -COVE BASE OR BULLNOSE PAPER TOWEL DISPENSER (REQUIR.ED) SOAP DISPENSER (REQUIRED) FONTHILL PEAR LAMINATE ( WILSONART #10745 -60) SANITARY COVE BASE (IF REQUIRED BY LOCAL HEALTH) " ' [15.62cm] EMPLOYEE SIDE 0 N, If 0) in I SERVICE AREA - SIDE FACING ELEVATION (TYPICAL) (SEE GENERAL NOTES 1, 2, 3 & 5) UPPER 1 1/2" DECORATIVE TRIM MOLDING MAIZE TONE CITYSCAPE MURAL LOWER 2 1/2" CHAIR > s1�.■,wl� ■r��i ( l�.■ �■ i ris, .11 I�I ■rrus■. �__,�1r L- s■Ir!I 1011111111100 1 I . s■r1 -' r+l■ ii■Is.�J- - Islrlr(�s�slrlslr - 1-0 -4 ".■1■F■■wl 11- ' �I mit � �w-- 1�"�r''rrrrrrrr� ��■t- Lr"r�i1�' I� • I -- iss 1•11 1•11 ■I I 0_91 rl a a¢ f a i o C il NI OP NM I I - BREAD i BREAD - ill - BAKING : 'I IIA _CABINET (: OVEN - !� 1 al MENUBOARD / \V\ 1� BUTTERNUT BRICK + WALL COVERING JI L "15 I J L ._ Jl f iL I 1•111101111111110 mi l_ 1•0111A 01111011111110101•111111111111 01•10111111111111110111011 IMO ■r.� MINN •1• r(�i 1000 ■ r■ r1■■Ir _r■ I■�■1 �1r■ was, 1 �s,�las■ rural COUNTER TOP 1" X 12" HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) U N N, u HAND SANITIZER DISPENSER (OPTIONAL) SERVICE AREA - FRONT FACING ELEVATION (TYPICAL) (SEE GENERAL NOTES 1, 2, 3 & 5) ao CUSTOMER AREA "RED" WALL ELEVATION(OPTIONAL) (SEE GENERAL NOTES 1, 2 & 5) 0 0 0i N N u U rn N I--' w _ z J W 0 u I- _ 0 w x 0 z J w 0 SIDE WALL SIDE WALL E 0 N Fri 0 N I cv M a E 0 M I; rn 3/4" MILLED ALUMINUM FONTHILL PEAR T- MOLDING #ALU -1028 LAMINATE (TYP) VC SUPPLIED BY (WILSONART OUTWATER PLASTIC #10745 -60) INDUSTRIES INC. INSTALL GRAIN SIDE VIEW HORIZONTALLY (SHOWN WITH COUNTER ENTRANCE AND BUILT SOFFIT WALL OPTION) FRAMED AND DRYWALLED SOFFIT ABOVE FRONT AND SIDE OF SERVICE AREA. FINISH OPTIONS: 1) QUENTIN WALLCOVERING. 2) BUTTERNUT BRICK WALLCOVERING. 3) FONT HILL PEAR LAMINATE (WILSONART #10745 -60) 4) BLONDE PAINT (SHERWIN WILLIAMS SW6128) 5) FIRED BRICK RED PAINT (SHERWIN WILLAMS SW6335) IN1NI1UPAIJU0V11 )l•1.0.V_leNIP FIIF NO:l•IbF:e!NI Gig *FPJ• l!L,MP COUNTER TOP HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) 3/4" MILLED ALUMINUM T- MOLDING #ALU -1028 VC SUPPLIED BY OUTWATER PLASTIC INDUSTRIES INC. OPTIONAL: 4 1/2" HARDWOOD CROWN MOLDING (MINIMUM 8'- 6 "[259.1cm] CEIILING HEIGHT REQUIRED FOR THIS OPTION) 4" WIDE PURSE RAIL WITH LIGHTS AND FONTHILL PEAR FINISH M E rn COVEBASE OR BULLNOSE RED WALL COVERING (REFER TO FLOOR PLAN FOR EXACT PLACEMENT) NOTE: NO UPPER DECORATIVE MOLDING INSTALLED FOR ENTIRE NS SECTION OF RED WALL COVERING. LOWER 2 1/2" CHAIR RAIL MOLDING TUSCAN STUCCO WALL COVERING (CONTINUOUS ROLL) COVE BASE OR BULLNOSE z J w 0 io CD �II IIIIIIII I MOSAIC TILE PATTERN* (PANEL "A ") FRONT SERVICE COUNTER ELEVATION (TYPICAL) (SEE GENERAL NOTES 1, 2, 4 & 6) NOTE: AREA BELOW HARDWOOD PLANK TO BE FINISHED WITH LOWER CHAIR RAIL MOULDING (STAINED MINWAX #235 CHERRY AND POLYRETHANED WITH MINWAX FAST DRYING CLEAR SATIN) TUSCAN STUCCO - WALL COVERING (CONTINUOUS ROLL) JA #587 -1 COVE BASE OR BULLNOSE SUPPLIER - HOUSE OF FARA DEE - HARDWOOD FINISH - STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN. FRONT SUPPLIER -- HOUSE OF FARA TYPE - HARDWOOD FINISH - STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN. OPTIONAL: WITH FRAMED AND DRYWALLED SOFFIT ONLY. COPPER CORNICE TRIM WITH 3 1/2" PROJECTION (CHICAGO METALLIC #63.40,035 TO ORDER CALL 1- 800 - 323 -7164) III MOSAIC TILE PATTERN* (PANEL "B ") FRONT 2' -0" 60.9cm OPENING FOR FRONT LINE BREAD CABINET (OPTIONAL) FRONT VIEW (SHOWN WITH BUILT SOFFIT WALL OPTION. *CEILING MUST BE MIN. 9' -0" TO USE THIS OPTION) 1" X 8" HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) 8" [20.3cm] 4' 4' SEATING DIVIDER WALL (TYPICAL) (SEE GENERAL NOTES 1 & 2) SQUARE; FRAMED WALL ART NOTES: •EIGHT DIFFERENT PRINTS AVAILABLE (SHOWN ABOVE). CAN BE ORDERED INDIVIDUALLY OR IN SETS. •COLOR PHOTOGRAPHS DOUBLE MATTED. •BLACK WOODEN FRAME WITH PLEXIGLAS. •MOUNTED TO WALL USING HANGING /SECURITY HARDWARE (SUPPLIED WITH EACH WALL ART PIECE). • DIM. 26 "W X 26 "H X 1" DEEP •HUNG ON WALL BETWEEN UPPER AND LOWER CHAIR RAIL MOLDING. REFER TO FLOOR PLAN FOR EXACT PLACEMENT. WALL ART - SQAURE HARDWOOD CROWN MOLDING LOWER CHAIR RAIL MOLDING IIIIIIIIII COVEBASE OR BULLNOSE MOSAIC TILE PATTERN TO BE FRAMED WITH FONTHILL PEAR LAMINATE (WILSONART #10745 -60) PROFILE III 0 , ...mlom vvmnra vl•Ivmmwwox mm!vmmly iii •IL•.vivo,.vv!mmla.vvvwommry mmmlvm ,vmmlv,mlvmmmwemmmw 4" WIDE PURSE RAIL WITH LIGHTS AND FONTHILL PEAR FINISH FONTHILL PEAR LAMINATE (TYP) (WILSON ART #10745 -60) INSTALL GRAIN HORIZONTALLY 3/4" MILLED ALUMINUM T- MOLDING #ALU -1028 VC SUPPLIED BY OUTWATER PLASTIC INDUSTRIES INC. *NOTE: FOR A MORE PRIVATE AND /OR UPSCALE APPEARANCE THE INSTALLATION OF GLASS BLOCK OR ETCHED GLASS DIVIDERS MAY BE INSTALLED ON TOP OF THE 1" X 8" HARDWOOD PLANK. COVEBASE BULLNOSE #102 -1 TUSCAN STUCCO \ WALL COVERING COVE BASE OR BULLNOSE 5/8" DRYWALL 2" X 4" WOOD OR METAL FRAMING 012 SUPPLIER - CHICAGO METALLIC FINISH - COPPER 3 1/2" PROJECTION CONVEX FACE #63.40.035 gag COPPER CORNICE TRIM MOLDINGS (OPTIONAL) w LI.I a w \ FRONT UPPER DECORATIVE TRIM MOLDING FRONT MOLDINGS (REQUIRED) COUNTER TOP HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) \ 1" X 4" HARDWOOD SOFFIT (MOUNTED VERTICALLY) ABOVE FRONT AND SIDE OF SERVICE AREA. STAIN MINWAX #235 CHERRY AND POLYURETHANE WITH MINWAX FAST DRYING CLEAR SATIN. I I'IIIIIIIIIII OR 3/4" MILLED ALUMINUM T- MOLDING #ALU -1028 VC SUPPLIED BY OUTWATER PLASTIC INDUSTRIES INC. SIDE VIEW (SHOWN WITHOUT COUNTER ENTRANCE AND 1" X 4" OR 4" X 4" SOFFIT OPTION) UPPER :DECORATIVE TRIM 12" [30.5cm] TYPICAL VERTICAL WALL ART NOTES: •EIGHT DIFFERENT PRINTS AVAILABLE (SHOWN LEFT). CAN BE ORDERED INDIVIDUALLY OR IN SETS, •GRAPHICS PRINTED ONTO STYRENE FACED FOAM BOARD. •BLACK ALUMINUM FRAME. •MOUNTED TO WALL USING HANGING /SECURITY HARDWARE (SUPPLIED WITH EACH WALL ART PIECE). •DIM. 22 3/4 "W X 49 3/4 "H X 1" DEEP. •HUNG ON WALL BETWEEN UPPER AND LOWER CHAIR RAIL MOLDING. TYPICAL MOUNTING SHOWN BELOW. REFER TO FLOOR PLAN FOR EXACT PLACEMENT. NOTE: CAN NOT BE USED ABOVE BANQUETTE WALL BENCH SEATING. WALL PLANT MOUNTING BRACKET TO BE MOUNTED 15" [38.1cm] BELOW THE TOP OF THE UPPER DECORATIVE TRIM. TYPICAL LOWER CHAIR RAIL MOLDING GROUPS OF THREE PRINTS 12" [30.5cm] TYPICAL GROUPS OF TWO PRINTS PANEL "A" (LEFT SIDE) NOTES: 1.) GRAPHIC IMAGES TO BE PRINTED ONTO PANELS AND VACUUM FORMED TO CREATE THE APPEARANCE OF 4 1/4" X 4 1/4" CERAMIC TILES WITH 1/16" GROUT JOINTS. 2.) FOR CONVENIENCE THE FRAMED VACUFORM TILE AND LAMINATES CAN BE ORDERED FOR BOTH NEW AND REIIODELING LOCATIONS A LA CARTE FROM DUKE MANUFACTURING. ALL FRONT COUNTER UNITS ARE SHIPPED WITH A COMPREHENSIVE INSTALLATION GUIDE, FROM THE MANUFACTURER, ON THE ENTIRE PROCESS, FROM COUNTER SET -UP TO DECOR INSTALLATION. PROFILE SIDE WALL FONTHILL PEAR LAMINATE (TYP) (WILSON ART #10745 -60) INSTALL GRAIN HORIZONTALLY WITH CITYSCAPE MURAL WALL PLANT MOUNTING BRACKET TO BE MOUNTED 15" [38.1cm] BELOW THE TOP OF THE UPPER DECORATIVE TRIM. TYPICAL CITYSCAPE MURAL "- -LOWER CHAIR RAIL MOLDING WALL ART - VERTICAL PANEL "B" (RIGHT SIDE) MOSAIC TILE PATTERNS GENERAL NOTES: 1. ALL. HORIZONTAL DIMENSIONS ARE AS PER FLOOR PLANS UNLESS OTHERWISE NOTED. 2. BULLNOSE TO BE USED WHEREVER PORCELAIN FLOOR TILE IS USED UNLESS LOCAL HEALTH REQUIRES A SANITARY COVE BASE. 3. STORES WITH CEILING HEIGHTS OF 8' -8" [264.2cm] OR GREATER MAY INSTALL THE MENUBOARD OVER THE OVEN. REFER TO PLANS FOR EXACT PLACEMENT. FOR LOWER CEILING HEIGHTS REFER TO FLOOR PLANS FOR ALTERNATE MENUBOARD PLACEMENT. 4. FOR LOCATIONS WITH NEW DUKE FRONT COUNTERS, THE FINISH MATERIALS FOR THE FRONT FACE OF THE UNIT (MOSAIC TILE PATTERNS(S) WITH FONTHILL PEAR FRAMING WITH 3/4" T- MOLDING) ARE SHIPPED WITH THE COUNTER PREFABRICATED AND READY TO INSTALL. THIS APPLIES ONLY IF THE MATERIALS ARE TO BE INSTALLED DIRECTLY ONTO THE FRONT OF THE UNIT. PREFABRICATED AND FINISHED 36" AND 48" SERVICE AREA SIDE WALLS AND COUNTER ENTRANCE GATES ARE ALSO AVAILABLE FROM DUKE MANUFACTURING. 5. SEE CHAIR RAIL MOLDING DETAIL (THIS PAGE) FOR STYLE, FINISH AND PROPER PLACEMENT. 6. ALTERNATE COUNTER SIZES MAY VARY MOSAIC TILE PATTERN PLACEMENT. PLEASE REFER TO DRAWING FOR EXACT PLACEMENT. SUNGLO CITYSCAPE MURAL FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE SUNGLO TUSCAN STUCCO WALL COVERING FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE SUNGLO BUTTERNUT BRICK WALL COVERING FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE SUNGLO QUENTIN WALL COVERING FLAME SPREAD INDEX FUE: CONTRIBUTED VALUE SMOKE DEVELOPED VALUE SUNGLO RED WALL COVERING FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE WILSONART LAMINATE (G.P.) FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE MARLITE FIBERGLASS REINFORCED PANELS FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE VACUFORM MOSAIC TILE: PHYSICAL PROPERTY EIRE RATINGS DRYWALL UNBONDED 10 0 5 15 5 10 15 5 20 10 0 5 15 0 20 200 0 450 HEAT DEFLECTION TEMP (ANNEALED) ©264 PSI FLAMMABILITY RATING UNDERWRITERS LAB REVI5.WI CODE CON MAR 1 2 CNI BUILDING STRESS 55 0 30 FIRE AND EXPLOSION HAZARD DATA FLASH POINT: 425•F, 218 a (COC) AUTOIGNITION TEMPERATURE. NO DATA FLAMMABLE LIMITS (STP): NO DATA UPPER DECORATIVE TRIM WOOD PARTICLE BOARD D FOR PLIANCE If 2009 ukwffa )IVIS CITY OF TUKWILA FEB 0 2 ?IIII.y PERMIT CENTER TYPE 107 80 0 95 TYPE 335 TYPE 350 70 65 0 0 135 105 TEST METHOD ASTM D -648 UL 94 V -0 UNITS DEGREES F TYPICAL VALUES 155 PASSES STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ("DAI ") D /B /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND /OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAPS AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAPS STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. 1 SHEET #: 1 of 4 ©2008 DOCTORS ASSOCIATES, INC. : WALL ART PRINT A WALL ART PRINT/ I,/ 6' '(MINIMUM) WALL ART ,PRINT WALL ART PRINT/ WALL ART /PRINT WALL ART PRINT In 6' (MINIMUM) [182.9cm] [182.9cm] 1" X 2" SHELF BRACE IN BETWEEN FIXTURES LIGHT FIXTURE CROWN MOLDING 1 "X4 "SHE OPTIONAL: UPPER WALL LIGHTING STRIP SURFACE FLUORESCENT FIXTURES. MANUFACTURER: NORA LIGHTING. MODEL#: NULS -28 4' LONG)(F28T5 BULB NULS -21 3' LONG)(F21T5 BULB UP TO (10 NULS -28 AND /OR NULS -21 FIXTURES MAY BE CONNECTED TO SINGLE 120V POWER CORD FEED. PLACED ABOVE UPPER DECORATIVE TRIM (NOT OVER WINDOWS). MOUNT ON 1" X 4" SHELF WITH 4 1/2" CROWN MOLDING (BY HOUSE OF FARA TO HIDE FIXTURES (SHELF AND MOLDING TO BE STAINED 2 COATS MINWAX #235 CHERRY AND POLY - URETHANED WITH MINWAX FAST DRYING SATIN) (D SECTION VIEW SIDE WALL 1" X 2 1/2" BLOCK 0 0 Oi N N CUSTOMER AREA WALL ELEVATION(TYPICAL) (SEE GENERAL NOTES 1, 2 & 5) OPTIONAL: 4 1/2" HARDWOOD CROWN MOLDING (MINIMUM 8'- 6 "[259.1cm] CEIILING B UTTERNUT BRICK HEIGHT REQUIRED FOR THIS OPTION) ALL COVERING _I N L_JI it I L-JI L J L-JL I L -II 1L L�JI L I ■■■ = L_J J TE -- am i 1�■ LT 1 r �■I r MOM r i �ri�t�i■r =■ ■_lid il■ =� ■_iSri�l�i■■■ i� i'■�irl_iI■ OPTIONAL: 4 1/2" HARDWOOD CROWN MOLDING (MINIMUM 8' -6 "[259.1 cm] CEIILING HEIGHT REQUIRED FOR THIS OPTION) SIDE BACK COUNTERS PAPER WALL SIDES AND DOORS: FONT HILL PEAR TOWEL SOAP - LAMINATE (WILSONART #10745 -60) DISPENSER DISPENSER HAND (INSTALL GRAIN HORIZONTALLY) (REQUIRED) (REQUIRED) DISPENSER TOP: STAINLESS STEEL (OPTIONAL) I f 1 SIDE TUSCAN STUCCO / WALL WALL COVERING BACK COUNTERS J COVE BASE OR BULLNOSE • ALL NEW DUKE FRONT COUNTERS ARE SHIPPED WITH PREFABRICATED DECOR PANELS READY TO INSTALL. •PREFABRICATED DECOR PANELS ARE AVAILABLE READY TO INSTALL FOR SITE BUILT 36" AND 48" HIGH SERVICE AREA WALLS AND ARE MADE TO ORDER. •ALSO AVAILABLE FROM DUKE MANUFACTURING ARE PREBUILT, PREFINISHED MADE TO ORDER 36" AND 48" HIGH SERVICE AREA SIDE AND FRONT WALLS WITH OR WITHOUT PREFINISHED COUNTER ENTRANCE GATE. •PREFABRICATED DECOR PANELS ARE AVAILABLE FOR EXISTING FRONT COUNTERS AS WELL. COUNTER ENTRANCE FINISH OPTIONS: OPTION #1 (PREFERRED) PREFINISHED & PREFRAMED COUNTER ENTRANCE GATE AVAILBALE THROUGH PLYMOLD AND DUKE MANUFACTURING. OPTION #2 GLUE TOGETHER 2 PIECES OF 5/8" PARTICLE BOARD AND FINISH WITH WILSONART #10745 -60 FONTHILL PEAR LAMINATE. EDGE WITH 1 1/2" HARDWOOD MOLDING (STAINED WITH MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN). SECURE WITH HEAVY DUTY HINGES AND INSTALL A BAR LATCH ON THE EMPLOYEE SIDE. 7- OPTIONAL: 4 1/2" HARDWOOD CROWN MOLDING (MINIMUM 8'- 6 "[259.1cm] CEIILING HEIGHT REQUIRED FOR THIS OPTION) OPTION 1) QUENTIN WALLCOVERING OPTION 2) BUTTERNUT BRICK WALLCOVERING. I I I SIDES AND DOORS: FONT HILL PEAR LAMINATE (WILSONART #10745 -60) (INSTALL GRAIN HORIZONTALLY) TOP: STAINLESS STEEL FONTHILL PEAR LAMINATE (WILSONART #10745 -60) W /MILLED ALUMINUM TEE MOLDING � COVEBASE OR-1 BULLNOSE 5/8" DRYWALL 2" X 4" WOOD OR METAL FRAMING OPTION 1) QUENTIN WALLCOVERING OPTION 2) BUTTERNUT BRICK WALLCOVERING. UPPER 1 1/2" DECORATIVE TRIM MOLDING EMPIRE TRIM - 9" (UPPER PORTION OF MAIZE TONE CITYSCAPE MURAL) 12' ALTERNATING MAIZE TONE CITYSCAPE MURAL PANELS, A & B LOWER 2 1/2" CHAIR RAIL MOLDING TUSCAN STUCCO WALL COVERING (CONTINUOUS ROLL) COVE BASE OR BULLNOSE T OPTION 1) QUENTIN WALLCOVERING OPTION 2) BUTTERNUT BRICK WALLCOVERING. .; m oi am • ` M.= I��L��1� � MMII. 1�■ �1� �1��1���1��1■• �1� ■�I��l■1�■�I■t�l■�R�� r ■■,�� �■�■■� sus �■� �° �, 1r�1�■ �■■l� ■s�■1■ �■((� r a m ■r •■w■■�wml■�■_1 l ■-1�_ ' _1 ir ■■■ ss�■r■■�■s -_Ii MI - 1_�i� ■l is ow or sr sr sr ■�• ■r MANN MOM oo ■ 1 r �`s ' l � s war or ow on IN rr■r■■■ I r ■.r�nlss■■rlllsl�ss.■.rr i 71. ._J .rrr� �� � � � l■rw rr■.■1s r■S■I.r�s 1■IrM�■1al■s� � -I r■ I ' sr �a..C�o■ r L M `c� r c� r s■_ -I ale � r � r rr ■ :■��I , L WI ri�r�� El ■ "! r row - - BREAD Ir. : BRI EAD : i7 ros _CABINET Ini ' - BAKING : II. s■s■■NC�C�■ - --■ 1140101 ■ - _ OVEN - LI - rim r[r■■ r - PE , IN was ro 1T lI11al- �,t■�■T.IAIM MP= MENUBOARD UPPER 1 1/2" DECORATIVE TRIM MOLDING --- TONE CITYSCAPE MURAL LOWER 2 1/2" CHAIR - RAIL MOLDING CUSTOMER SI \ a cNI N M TUSCAN STUCCO WALL COVERING -COVE BASE OR BULLNOSE PAPER TOWEL DISPENSER (REQUIR.ED) SOAP DISPENSER (REQUIRED) FONTHILL PEAR LAMINATE ( WILSONART #10745 -60) SANITARY COVE BASE (IF REQUIRED BY LOCAL HEALTH) " ' [15.62cm] EMPLOYEE SIDE 0 N, If 0) in I SERVICE AREA - SIDE FACING ELEVATION (TYPICAL) (SEE GENERAL NOTES 1, 2, 3 & 5) UPPER 1 1/2" DECORATIVE TRIM MOLDING MAIZE TONE CITYSCAPE MURAL LOWER 2 1/2" CHAIR > s1�.■,wl� ■r��i ( l�.■ �■ i ris, .11 I�I ■rrus■. �__,�1r L- s■Ir!I 1011111111100 1 I . s■r1 -' r+l■ ii■Is.�J- - Islrlr(�s�slrlslr - 1-0 -4 ".■1■F■■wl 11- ' �I mit � �w-- 1�"�r''rrrrrrrr� ��■t- Lr"r�i1�' I� • I -- iss 1•11 1•11 ■I I 0_91 rl a a¢ f a i o C il NI OP NM I I - BREAD i BREAD - ill - BAKING : 'I IIA _CABINET (: OVEN - !� 1 al MENUBOARD / \V\ 1� BUTTERNUT BRICK + WALL COVERING JI L "15 I J L ._ Jl f iL I 1•111101111111110 mi l_ 1•0111A 01111011111110101•111111111111 01•10111111111111110111011 IMO ■r.� MINN •1• r(�i 1000 ■ r■ r1■■Ir _r■ I■�■1 �1r■ was, 1 �s,�las■ rural COUNTER TOP 1" X 12" HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) U N N, u HAND SANITIZER DISPENSER (OPTIONAL) SERVICE AREA - FRONT FACING ELEVATION (TYPICAL) (SEE GENERAL NOTES 1, 2, 3 & 5) ao CUSTOMER AREA "RED" WALL ELEVATION(OPTIONAL) (SEE GENERAL NOTES 1, 2 & 5) 0 0 0i N N u U rn N I--' w _ z J W 0 u I- _ 0 w x 0 z J w 0 SIDE WALL SIDE WALL E 0 N Fri 0 N I cv M a E 0 M I; rn 3/4" MILLED ALUMINUM FONTHILL PEAR T- MOLDING #ALU -1028 LAMINATE (TYP) VC SUPPLIED BY (WILSONART OUTWATER PLASTIC #10745 -60) INDUSTRIES INC. INSTALL GRAIN SIDE VIEW HORIZONTALLY (SHOWN WITH COUNTER ENTRANCE AND BUILT SOFFIT WALL OPTION) FRAMED AND DRYWALLED SOFFIT ABOVE FRONT AND SIDE OF SERVICE AREA. FINISH OPTIONS: 1) QUENTIN WALLCOVERING. 2) BUTTERNUT BRICK WALLCOVERING. 3) FONT HILL PEAR LAMINATE (WILSONART #10745 -60) 4) BLONDE PAINT (SHERWIN WILLIAMS SW6128) 5) FIRED BRICK RED PAINT (SHERWIN WILLAMS SW6335) IN1NI1UPAIJU0V11 )l•1.0.V_leNIP FIIF NO:l•IbF:e!NI Gig *FPJ• l!L,MP COUNTER TOP HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) 3/4" MILLED ALUMINUM T- MOLDING #ALU -1028 VC SUPPLIED BY OUTWATER PLASTIC INDUSTRIES INC. OPTIONAL: 4 1/2" HARDWOOD CROWN MOLDING (MINIMUM 8'- 6 "[259.1cm] CEIILING HEIGHT REQUIRED FOR THIS OPTION) 4" WIDE PURSE RAIL WITH LIGHTS AND FONTHILL PEAR FINISH M E rn COVEBASE OR BULLNOSE RED WALL COVERING (REFER TO FLOOR PLAN FOR EXACT PLACEMENT) NOTE: NO UPPER DECORATIVE MOLDING INSTALLED FOR ENTIRE NS SECTION OF RED WALL COVERING. LOWER 2 1/2" CHAIR RAIL MOLDING TUSCAN STUCCO WALL COVERING (CONTINUOUS ROLL) COVE BASE OR BULLNOSE z J w 0 io CD �II IIIIIIII I MOSAIC TILE PATTERN* (PANEL "A ") FRONT SERVICE COUNTER ELEVATION (TYPICAL) (SEE GENERAL NOTES 1, 2, 4 & 6) NOTE: AREA BELOW HARDWOOD PLANK TO BE FINISHED WITH LOWER CHAIR RAIL MOULDING (STAINED MINWAX #235 CHERRY AND POLYRETHANED WITH MINWAX FAST DRYING CLEAR SATIN) TUSCAN STUCCO - WALL COVERING (CONTINUOUS ROLL) JA #587 -1 COVE BASE OR BULLNOSE SUPPLIER - HOUSE OF FARA DEE - HARDWOOD FINISH - STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN. FRONT SUPPLIER -- HOUSE OF FARA TYPE - HARDWOOD FINISH - STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN. OPTIONAL: WITH FRAMED AND DRYWALLED SOFFIT ONLY. COPPER CORNICE TRIM WITH 3 1/2" PROJECTION (CHICAGO METALLIC #63.40,035 TO ORDER CALL 1- 800 - 323 -7164) III MOSAIC TILE PATTERN* (PANEL "B ") FRONT 2' -0" 60.9cm OPENING FOR FRONT LINE BREAD CABINET (OPTIONAL) FRONT VIEW (SHOWN WITH BUILT SOFFIT WALL OPTION. *CEILING MUST BE MIN. 9' -0" TO USE THIS OPTION) 1" X 8" HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) 8" [20.3cm] 4' 4' SEATING DIVIDER WALL (TYPICAL) (SEE GENERAL NOTES 1 & 2) SQUARE; FRAMED WALL ART NOTES: •EIGHT DIFFERENT PRINTS AVAILABLE (SHOWN ABOVE). CAN BE ORDERED INDIVIDUALLY OR IN SETS. •COLOR PHOTOGRAPHS DOUBLE MATTED. •BLACK WOODEN FRAME WITH PLEXIGLAS. •MOUNTED TO WALL USING HANGING /SECURITY HARDWARE (SUPPLIED WITH EACH WALL ART PIECE). • DIM. 26 "W X 26 "H X 1" DEEP •HUNG ON WALL BETWEEN UPPER AND LOWER CHAIR RAIL MOLDING. REFER TO FLOOR PLAN FOR EXACT PLACEMENT. WALL ART - SQAURE HARDWOOD CROWN MOLDING LOWER CHAIR RAIL MOLDING IIIIIIIIII COVEBASE OR BULLNOSE MOSAIC TILE PATTERN TO BE FRAMED WITH FONTHILL PEAR LAMINATE (WILSONART #10745 -60) PROFILE III 0 , ...mlom vvmnra vl•Ivmmwwox mm!vmmly iii •IL•.vivo,.vv!mmla.vvvwommry mmmlvm ,vmmlv,mlvmmmwemmmw 4" WIDE PURSE RAIL WITH LIGHTS AND FONTHILL PEAR FINISH FONTHILL PEAR LAMINATE (TYP) (WILSON ART #10745 -60) INSTALL GRAIN HORIZONTALLY 3/4" MILLED ALUMINUM T- MOLDING #ALU -1028 VC SUPPLIED BY OUTWATER PLASTIC INDUSTRIES INC. *NOTE: FOR A MORE PRIVATE AND /OR UPSCALE APPEARANCE THE INSTALLATION OF GLASS BLOCK OR ETCHED GLASS DIVIDERS MAY BE INSTALLED ON TOP OF THE 1" X 8" HARDWOOD PLANK. COVEBASE BULLNOSE #102 -1 TUSCAN STUCCO \ WALL COVERING COVE BASE OR BULLNOSE 5/8" DRYWALL 2" X 4" WOOD OR METAL FRAMING 012 SUPPLIER - CHICAGO METALLIC FINISH - COPPER 3 1/2" PROJECTION CONVEX FACE #63.40.035 gag COPPER CORNICE TRIM MOLDINGS (OPTIONAL) w LI.I a w \ FRONT UPPER DECORATIVE TRIM MOLDING FRONT MOLDINGS (REQUIRED) COUNTER TOP HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) \ 1" X 4" HARDWOOD SOFFIT (MOUNTED VERTICALLY) ABOVE FRONT AND SIDE OF SERVICE AREA. STAIN MINWAX #235 CHERRY AND POLYURETHANE WITH MINWAX FAST DRYING CLEAR SATIN. I I'IIIIIIIIIII OR 3/4" MILLED ALUMINUM T- MOLDING #ALU -1028 VC SUPPLIED BY OUTWATER PLASTIC INDUSTRIES INC. SIDE VIEW (SHOWN WITHOUT COUNTER ENTRANCE AND 1" X 4" OR 4" X 4" SOFFIT OPTION) UPPER :DECORATIVE TRIM 12" [30.5cm] TYPICAL VERTICAL WALL ART NOTES: •EIGHT DIFFERENT PRINTS AVAILABLE (SHOWN LEFT). CAN BE ORDERED INDIVIDUALLY OR IN SETS, •GRAPHICS PRINTED ONTO STYRENE FACED FOAM BOARD. •BLACK ALUMINUM FRAME. •MOUNTED TO WALL USING HANGING /SECURITY HARDWARE (SUPPLIED WITH EACH WALL ART PIECE). •DIM. 22 3/4 "W X 49 3/4 "H X 1" DEEP. •HUNG ON WALL BETWEEN UPPER AND LOWER CHAIR RAIL MOLDING. TYPICAL MOUNTING SHOWN BELOW. REFER TO FLOOR PLAN FOR EXACT PLACEMENT. NOTE: CAN NOT BE USED ABOVE BANQUETTE WALL BENCH SEATING. WALL PLANT MOUNTING BRACKET TO BE MOUNTED 15" [38.1cm] BELOW THE TOP OF THE UPPER DECORATIVE TRIM. TYPICAL LOWER CHAIR RAIL MOLDING GROUPS OF THREE PRINTS 12" [30.5cm] TYPICAL GROUPS OF TWO PRINTS PANEL "A" (LEFT SIDE) NOTES: 1.) GRAPHIC IMAGES TO BE PRINTED ONTO PANELS AND VACUUM FORMED TO CREATE THE APPEARANCE OF 4 1/4" X 4 1/4" CERAMIC TILES WITH 1/16" GROUT JOINTS. 2.) FOR CONVENIENCE THE FRAMED VACUFORM TILE AND LAMINATES CAN BE ORDERED FOR BOTH NEW AND REIIODELING LOCATIONS A LA CARTE FROM DUKE MANUFACTURING. ALL FRONT COUNTER UNITS ARE SHIPPED WITH A COMPREHENSIVE INSTALLATION GUIDE, FROM THE MANUFACTURER, ON THE ENTIRE PROCESS, FROM COUNTER SET -UP TO DECOR INSTALLATION. PROFILE SIDE WALL FONTHILL PEAR LAMINATE (TYP) (WILSON ART #10745 -60) INSTALL GRAIN HORIZONTALLY WITH CITYSCAPE MURAL WALL PLANT MOUNTING BRACKET TO BE MOUNTED 15" [38.1cm] BELOW THE TOP OF THE UPPER DECORATIVE TRIM. TYPICAL CITYSCAPE MURAL "- -LOWER CHAIR RAIL MOLDING WALL ART - VERTICAL PANEL "B" (RIGHT SIDE) MOSAIC TILE PATTERNS GENERAL NOTES: 1. ALL. HORIZONTAL DIMENSIONS ARE AS PER FLOOR PLANS UNLESS OTHERWISE NOTED. 2. BULLNOSE TO BE USED WHEREVER PORCELAIN FLOOR TILE IS USED UNLESS LOCAL HEALTH REQUIRES A SANITARY COVE BASE. 3. STORES WITH CEILING HEIGHTS OF 8' -8" [264.2cm] OR GREATER MAY INSTALL THE MENUBOARD OVER THE OVEN. REFER TO PLANS FOR EXACT PLACEMENT. FOR LOWER CEILING HEIGHTS REFER TO FLOOR PLANS FOR ALTERNATE MENUBOARD PLACEMENT. 4. FOR LOCATIONS WITH NEW DUKE FRONT COUNTERS, THE FINISH MATERIALS FOR THE FRONT FACE OF THE UNIT (MOSAIC TILE PATTERNS(S) WITH FONTHILL PEAR FRAMING WITH 3/4" T- MOLDING) ARE SHIPPED WITH THE COUNTER PREFABRICATED AND READY TO INSTALL. THIS APPLIES ONLY IF THE MATERIALS ARE TO BE INSTALLED DIRECTLY ONTO THE FRONT OF THE UNIT. PREFABRICATED AND FINISHED 36" AND 48" SERVICE AREA SIDE WALLS AND COUNTER ENTRANCE GATES ARE ALSO AVAILABLE FROM DUKE MANUFACTURING. 5. SEE CHAIR RAIL MOLDING DETAIL (THIS PAGE) FOR STYLE, FINISH AND PROPER PLACEMENT. 6. ALTERNATE COUNTER SIZES MAY VARY MOSAIC TILE PATTERN PLACEMENT. PLEASE REFER TO DRAWING FOR EXACT PLACEMENT. SUNGLO CITYSCAPE MURAL FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE SUNGLO TUSCAN STUCCO WALL COVERING FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE SUNGLO BUTTERNUT BRICK WALL COVERING FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE SUNGLO QUENTIN WALL COVERING FLAME SPREAD INDEX FUE: CONTRIBUTED VALUE SMOKE DEVELOPED VALUE SUNGLO RED WALL COVERING FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE WILSONART LAMINATE (G.P.) FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE MARLITE FIBERGLASS REINFORCED PANELS FLAME SPREAD INDEX FUEL CONTRIBUTED VALUE SMOKE DEVELOPED VALUE VACUFORM MOSAIC TILE: PHYSICAL PROPERTY EIRE RATINGS DRYWALL UNBONDED 10 0 5 15 5 10 15 5 20 10 0 5 15 0 20 200 0 450 HEAT DEFLECTION TEMP (ANNEALED) ©264 PSI FLAMMABILITY RATING UNDERWRITERS LAB REVI5.WI CODE CON MAR 1 2 CNI BUILDING STRESS 55 0 30 FIRE AND EXPLOSION HAZARD DATA FLASH POINT: 425•F, 218 a (COC) AUTOIGNITION TEMPERATURE. NO DATA FLAMMABLE LIMITS (STP): NO DATA UPPER DECORATIVE TRIM WOOD PARTICLE BOARD D FOR PLIANCE If 2009 ukwffa )IVIS CITY OF TUKWILA FEB 0 2 ?IIII.y PERMIT CENTER TYPE 107 80 0 95 TYPE 335 TYPE 350 70 65 0 0 135 105 TEST METHOD ASTM D -648 UL 94 V -0 UNITS DEGREES F TYPICAL VALUES 155 PASSES STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ("DAI ") D /B /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND /OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAPS AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAPS STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. 1 SHEET #: 1 of 4 ©2008 DOCTORS ASSOCIATES, INC. DATE: 10 -31 -08 DESIGNED BY: PATRICK ROSE DRAWN BY: PMR REVIEWED BY: PMR SCALE: NOT TO SCALE TYPICAL PENDANT FIXTURE INSTALLATION I- 2 O W O J W U z J D CC 0 0 L CC W 0- N 0 M U N (0 N u 1 25 7/16" SQ. [64.6cm] 23" SQ. 58.4cm 66" [167.6cm] [61.0cm] co U IC) MANUFACTURER - PLYMOLD WALL AND ISLAND STYLE. BENCH LENGTH: 2- SEATER 23" [58.4cm] 3-SEATER/4-SEATER 42" 106.7cm 5- SEATER /6- S EATER 59" [149 TABLETOP: 2- SEATER 24" X 23" [61cm X 58.4cm] 3- SEATER /4- SEATER 24" X 42" [61cm X 106.7cm] 5- SEATER /6- SEATER 24" X 59" [61cm X 149.9cm] TABLE TOP AND BENCH COLOR: FONT HILL PEAR (WILSONART #10745 -60) WITH BLACK DURA -EDGE COLORCOURT BOOTH (INCLUDING TYPICAL INSTALLATION OF PENDANT LIGHT) MANUFACTURER - PLYMOLD COLOR: FONT HILL PEAR WITH BLACK DURA -EDGE ( WILSONART #10745 -60) PLYMOLD TRASH UNITS NOTE: A "PENDANT STEM KIT" IS AVAILABLE THROUGH SPECIALTY STORE LIGHTING FOR USE WITH HIGH CEILINGS. AMBER PENDANT LIGHT FIXTURE (REFER TO FLOOR PLAN FOR EXACT PENDANT FIXTURE SIZE AND PLACEMENT) (0 M U rn NOTE: WHEN USING BOOTH SEATING A PENDANT LIGHT IS REQUIRED, IT SHOULD BE CENTERED WITH THE TABLE TOP. WHEN INSTALLING PENDANT LIGHTS, IN ANY APPLICATION, THEY SHOULD BE INSTALLED AT A HEIGHT OF 6' -6" [198.1cm] FROM THE FLOOR TO THE BOTTOM OF THE FIXTURE. IT IS RECOMMENDED THAT SEATS BE INSTALLED BEFORE THE PENDANT LIGHTS TO ALLOW FOR PRECISE PLACEMENT ABOVE TABLE TOPS. DOUBLE HOLE TRASH /RECYCLE UNIT (OPTIONAL) SINGLE HOLE TRASH UNIT SINGLE HOLE TRASH UNIT 1 I• U •1 MANUFACTURER - PLYMOLD WALL AND ISLAND STYLE. BENCH LENGTH: 2- SEATER 23" / 4- SEATER 42" TABLETOP: 2- SEATER 30" X 33" / 4- SEATER 30" X 42" AVAILABLE IN RIGHT OR LEFT BENCH TABLE TOP AND BENCH COLOR: FONT HILL PEAR (WILSONART #10745 -60) WITH BLACK DURA -EDGE COLORCOURT HANDICAP BOOTH 0 Ir) E U N N 7 30" X 42" TABLE [76.2cm X 106.6cm] (30" [76.2cm] HIGH) WITH 4- CHAIRS 51" 30" MANUFACTURER - PLYMOLD UPHOLSTERED FABRIC COVERED. AVAILABLE COLORS: STINSON GRAND SIERRA -BLACK (363492) OR MORBERN CARRARA - BUCK(TUSCAN BROWN). OPTIONAL FABRIC SEAT PAD OR BANQUETTE BACK PAD: STINSON (70006) 30" [76.2cm] NOTE: HANDICAPPED BOOTHS MUST BE SECURED TO THE FLOOR. O M MANUFACTURER - PLYMOLD TABLE TOP COLOR: FONT HILL PEAR ( WILSONART #10745 -60) WITH BLACK DURA -EDGE VERTICAL TABLE LEG AT EACH CORNER. FRAME FINISH COLOR: BLACK WRINKLE O M MANUFACTURER - PLYMOLD WALL AND ISLAND STYLE. BENCH LENGTH: 2- SEATER 23" [58.4cm] 3-SEATER/4-SEATER 42" 106.7cm 5 SEATER /6 S EATER 59" [ 149 . 9cm ] TABLETOP: 2- SEATER 24" X 23" [61cm X 58.4cm] 3- SEATER /4- SEATER 24" X 42" 61 cm X 106.7cm 5- SEATER /6- SEATER 24" X 59" [61 X 149.9cm TABLE TOP AND BENCH COLOR: FONT HILL PEAR (WILSONART #10745 -60) WITH BLACK DURA -EDGE FREE STANDING HANDICAP TABLE 20" X 24" TABLE [50.8cm X 61cm] (30" [76.2cm] HIGH) WITH 2- CHAIRS U N co N 1 [160.0cm] 24" [61.0cm] 63" J CONTOUR BOOTH 30" X 42" TABLE [76.2cm X 106.6cm] (30" [76.2cm] HIGH) TYPICAL 60" BANQUETTE ARRANGMENT 30" X 30" TABLE [76.2cm X 76.2cm] (30" [76.2cm] HIGH) WITH 4- CHAIRS NO CHAIR RAIL MOLDING INSTALLED FOR ENTIRE LENTGH OF BANQUETTE WALL BENCHES NOTE: HANDICAPPED BOOTHS MUST BE SECURED TO THE FLOOR. 0 M MANUFACTURER - PLYMOLD WALL AND ISLAND STYLE. BENCH LENGTH: 2- SEATER 23" / 4- SEATER 42" TABLETOP: 2- SEATER 30" X 33" / 4- SEATER 30" X 42" AVAILABLE IN RIGHT OF LEFT BENCH TABLE TOP AND BENCH COLOR: FONT HILL PEAR (WILSONART #10745 -60) WITH BLACK DURA -EDGE CONTOUR HANDICAP BOOTH MANUFACTURER - PLYMOLD TABLE TOP COLOR: FONT HILL PEAR ( WILSONART #10745 -60) WITH BLACK DURA -EDGE PLYMOLD SPIDER BASE HAS 3" COLUMN AND ADJUSTABLE LEVELERS. FRAME FINISH COLOR: BLACK WRINKLE 20" X 24" TABLE [50.8cm X 61cm] (30" [76.2cm] HIGH) TYPICAL SEATING ARRANGEMENTS 30" X 30" TABLE [76.2cm X 76.2cm] (30" [76.2cm] HIGH) 30" DIA. ROUND TABLE [76.cm DIA.] (42" [106.68cm] HIGH) WITH 3 -BAR HEIGHT STOOLS 20" X 24' TABLE -' [50.8cm X 61cm] (30" [76.2cm] HIGH) BANQUETTE WALL BENCH SEATING QUEST CHAIR: (USE WITH 30" HIGH TABLES) MANUFACTURER - PLYMOLD AVAILABLE WITH UPHOLSTERED AND DUR- -A -SEAT OPTION. AVAILABLE SEAT PAD COLORS: STINSON GRAND SIERRA - CROCUS (468479), SPICE (363497) AND SLATE (468482). FRAME COLOR: BLACK WRINKLE QUEST CHAIR AND STOOL 30" DIA. ROUND TABLE [76.2cm DIA.] (18" [45.7cm] HIGH) FREE STANDING TABLES 20" X 24' TABLE [50.8cm X 61cm] (30" [76.2cm] HIGH) FRONT ELEVATION - TYPICAL BANQUETTE WALL BENCH SEATING INSTALLATION AGAINST A FULL HEIGHT WALL FRONT ELEVATION - TYPICAL BANQUETTE WALL BENCH SEATING INSTALLATION AGAINST A 48" HIGH DIVIDER WALL QUEST BAR HEIGHT STOOL: (USE WITH 42" HIGH TABLES) 30" DIA. ROUND TABLE ' [76.cm DIA.] (42" [106.68cm] HIGH) 30" DIA. ROUND TABLE [76.2cm D!/ ,.] (18" [45.7cm] HIGH) WITH 2- UPHOLSTERED CHAIRS 26" X 26" [66cm X 66cm] FRAMED WALL ART NOTE: VERTICAL WALL ART CAN NOT BE USED ABOVE BANQUETTE WALL BENCH SEATING. QUEST CHAIR 6" [15.2cm] COUNTER TOP HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND QUEST CHAIR BANQUETTE WALL BENCH BANQUETTE WALL BENCH QUENTIN WALL COVERING COVEBASE OR BULLNOSE N M NO CHAIR RAIL MOLDING INSTALLED FOR ENTIRE LENTGH OF BANQUETTE WALL BENCHES E U M (0 MANUFACTURER - PLYMOLD UPHOLSTERED FABRIC COVERED. AVAILABLE COLORS: STINSON GRAND SIERRA -BLACK (363492) OR MORBERN CARRARA - BUCK(TUSCAN BROWN). OPTIONAL FABRIC SEAT PAD OR BANQUETTE BACK PAD: STINSON (70006) MANUFACTURER - PLYMOLD COUNTER TOP COLOR: FONT HILL PEAR (WILSONART #10745 -60) WITH BLACK DURA -EDGE 12" CANTILEVER. MINIMUM TWO CANTILEVERS PER COUNTER TOP. FRAME FINISH COLOR: BLACK WRINKLE 5/8" DRYWALL 2" X 4" WOOD OR METAL FRAMING 28" [71.1cm] SIDE ELEVATION L QUEST BAR HEIGHT STOOL 10 1/4" [26cm] W 1- ¢¢ E ct 0 J C 0 3 u N 10 1/4 [26cm] QUENTIN WALL COVERING COVEBASE OR BULLNOSE / N FRONT ELEVATION BANQUETTE WALL BENCH ARMCHAIR UPHOLSTERED FURNITURE iill�iiiililllli iililiii II iiiiiilliililli fil CANTILEVER INSTALLATION 20" X 24" TABLE [50.8cm X 61cm] (30" [76.2cm] HIGH) QUEST CHAIR SIDE ELEVATION - FULL HEIGHT WALL INSTALLATION 6" [15.2cm] COUNTER TOP HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) BANQUETTE WALL BENCH 20" X 24" TABLE [50.8cm X 61cm] (30" [76.2cm] HIGH) N QUEST CHAIR SIDE ELEVATION - 48" HIGH DIVIDER WALL INSTALLATION O M E U N (O N QUEST CHAIR - 12" CANTILEVER BRACKETS COUNTER TOP SEATING N LOVESEAT MANUFACTURER - PLYMOLD TABLE TOP COLOR: FONT HILL PEAR (WILSONART #10745 -60) WITH BLACK DURA -EDGE PLYMOLD BOLT -DOWN TABLE BASE HAS 3" COLUMN. FRAME FINISH COLOR: BLACK WRINKLE QUEST BAR HEIGHT STOOL - WINDOW FRONT ELEVATION BOLT -DOWN INSTALLATION COUCH 28 3/4" [73cm] SUPPORT FOR 30" HEIGHT. 40 3/4" [103.5cm] SUPPORT FOR 42" HEIGHT. BOLT -DOWN TABLE BASE QUEST CHAIR REVIEWED FOR CODE COMPLIANCE APPROVED MAR 1 2 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKIMLA FEB Q 2 1009 ERMIT CENTER U N (p N STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ( "DAI ") D /B /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND /OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAPS AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAPS STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. REVISION: m W Q 0 SHEET #: 2of4 ©2008 DOCTORS ASSOCIATES, INC. (luau i III MALL COVERING (ALL SIDES) POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) I 1 °L -d am -_ '_"- -'- - a" -, . ( I -- � �� NI _ - I II L -� m - TYPICAL PENDANT FIXTURE INSTALLATION I- 2 O W O J W U z J D CC 0 0 L CC W 0- N 0 M U N (0 N u 1 25 7/16" SQ. [64.6cm] 23" SQ. 58.4cm 66" [167.6cm] [61.0cm] co U IC) MANUFACTURER - PLYMOLD WALL AND ISLAND STYLE. BENCH LENGTH: 2- SEATER 23" [58.4cm] 3-SEATER/4-SEATER 42" 106.7cm 5- SEATER /6- S EATER 59" [149 TABLETOP: 2- SEATER 24" X 23" [61cm X 58.4cm] 3- SEATER /4- SEATER 24" X 42" [61cm X 106.7cm] 5- SEATER /6- SEATER 24" X 59" [61cm X 149.9cm] TABLE TOP AND BENCH COLOR: FONT HILL PEAR (WILSONART #10745 -60) WITH BLACK DURA -EDGE COLORCOURT BOOTH (INCLUDING TYPICAL INSTALLATION OF PENDANT LIGHT) MANUFACTURER - PLYMOLD COLOR: FONT HILL PEAR WITH BLACK DURA -EDGE ( WILSONART #10745 -60) PLYMOLD TRASH UNITS NOTE: A "PENDANT STEM KIT" IS AVAILABLE THROUGH SPECIALTY STORE LIGHTING FOR USE WITH HIGH CEILINGS. AMBER PENDANT LIGHT FIXTURE (REFER TO FLOOR PLAN FOR EXACT PENDANT FIXTURE SIZE AND PLACEMENT) (0 M U rn NOTE: WHEN USING BOOTH SEATING A PENDANT LIGHT IS REQUIRED, IT SHOULD BE CENTERED WITH THE TABLE TOP. WHEN INSTALLING PENDANT LIGHTS, IN ANY APPLICATION, THEY SHOULD BE INSTALLED AT A HEIGHT OF 6' -6" [198.1cm] FROM THE FLOOR TO THE BOTTOM OF THE FIXTURE. IT IS RECOMMENDED THAT SEATS BE INSTALLED BEFORE THE PENDANT LIGHTS TO ALLOW FOR PRECISE PLACEMENT ABOVE TABLE TOPS. DOUBLE HOLE TRASH /RECYCLE UNIT (OPTIONAL) SINGLE HOLE TRASH UNIT SINGLE HOLE TRASH UNIT 1 I• U •1 MANUFACTURER - PLYMOLD WALL AND ISLAND STYLE. BENCH LENGTH: 2- SEATER 23" / 4- SEATER 42" TABLETOP: 2- SEATER 30" X 33" / 4- SEATER 30" X 42" AVAILABLE IN RIGHT OR LEFT BENCH TABLE TOP AND BENCH COLOR: FONT HILL PEAR (WILSONART #10745 -60) WITH BLACK DURA -EDGE COLORCOURT HANDICAP BOOTH 0 Ir) E U N N 7 30" X 42" TABLE [76.2cm X 106.6cm] (30" [76.2cm] HIGH) WITH 4- CHAIRS 51" 30" MANUFACTURER - PLYMOLD UPHOLSTERED FABRIC COVERED. AVAILABLE COLORS: STINSON GRAND SIERRA -BLACK (363492) OR MORBERN CARRARA - BUCK(TUSCAN BROWN). OPTIONAL FABRIC SEAT PAD OR BANQUETTE BACK PAD: STINSON (70006) 30" [76.2cm] NOTE: HANDICAPPED BOOTHS MUST BE SECURED TO THE FLOOR. O M MANUFACTURER - PLYMOLD TABLE TOP COLOR: FONT HILL PEAR ( WILSONART #10745 -60) WITH BLACK DURA -EDGE VERTICAL TABLE LEG AT EACH CORNER. FRAME FINISH COLOR: BLACK WRINKLE O M MANUFACTURER - PLYMOLD WALL AND ISLAND STYLE. BENCH LENGTH: 2- SEATER 23" [58.4cm] 3-SEATER/4-SEATER 42" 106.7cm 5 SEATER /6 S EATER 59" [ 149 . 9cm ] TABLETOP: 2- SEATER 24" X 23" [61cm X 58.4cm] 3- SEATER /4- SEATER 24" X 42" 61 cm X 106.7cm 5- SEATER /6- SEATER 24" X 59" [61 X 149.9cm TABLE TOP AND BENCH COLOR: FONT HILL PEAR (WILSONART #10745 -60) WITH BLACK DURA -EDGE FREE STANDING HANDICAP TABLE 20" X 24" TABLE [50.8cm X 61cm] (30" [76.2cm] HIGH) WITH 2- CHAIRS U N co N 1 [160.0cm] 24" [61.0cm] 63" J CONTOUR BOOTH 30" X 42" TABLE [76.2cm X 106.6cm] (30" [76.2cm] HIGH) TYPICAL 60" BANQUETTE ARRANGMENT 30" X 30" TABLE [76.2cm X 76.2cm] (30" [76.2cm] HIGH) WITH 4- CHAIRS NO CHAIR RAIL MOLDING INSTALLED FOR ENTIRE LENTGH OF BANQUETTE WALL BENCHES NOTE: HANDICAPPED BOOTHS MUST BE SECURED TO THE FLOOR. 0 M MANUFACTURER - PLYMOLD WALL AND ISLAND STYLE. BENCH LENGTH: 2- SEATER 23" / 4- SEATER 42" TABLETOP: 2- SEATER 30" X 33" / 4- SEATER 30" X 42" AVAILABLE IN RIGHT OF LEFT BENCH TABLE TOP AND BENCH COLOR: FONT HILL PEAR (WILSONART #10745 -60) WITH BLACK DURA -EDGE CONTOUR HANDICAP BOOTH MANUFACTURER - PLYMOLD TABLE TOP COLOR: FONT HILL PEAR ( WILSONART #10745 -60) WITH BLACK DURA -EDGE PLYMOLD SPIDER BASE HAS 3" COLUMN AND ADJUSTABLE LEVELERS. FRAME FINISH COLOR: BLACK WRINKLE 20" X 24" TABLE [50.8cm X 61cm] (30" [76.2cm] HIGH) TYPICAL SEATING ARRANGEMENTS 30" X 30" TABLE [76.2cm X 76.2cm] (30" [76.2cm] HIGH) 30" DIA. ROUND TABLE [76.cm DIA.] (42" [106.68cm] HIGH) WITH 3 -BAR HEIGHT STOOLS 20" X 24' TABLE -' [50.8cm X 61cm] (30" [76.2cm] HIGH) BANQUETTE WALL BENCH SEATING QUEST CHAIR: (USE WITH 30" HIGH TABLES) MANUFACTURER - PLYMOLD AVAILABLE WITH UPHOLSTERED AND DUR- -A -SEAT OPTION. AVAILABLE SEAT PAD COLORS: STINSON GRAND SIERRA - CROCUS (468479), SPICE (363497) AND SLATE (468482). FRAME COLOR: BLACK WRINKLE QUEST CHAIR AND STOOL 30" DIA. ROUND TABLE [76.2cm DIA.] (18" [45.7cm] HIGH) FREE STANDING TABLES 20" X 24' TABLE [50.8cm X 61cm] (30" [76.2cm] HIGH) FRONT ELEVATION - TYPICAL BANQUETTE WALL BENCH SEATING INSTALLATION AGAINST A FULL HEIGHT WALL FRONT ELEVATION - TYPICAL BANQUETTE WALL BENCH SEATING INSTALLATION AGAINST A 48" HIGH DIVIDER WALL QUEST BAR HEIGHT STOOL: (USE WITH 42" HIGH TABLES) 30" DIA. ROUND TABLE ' [76.cm DIA.] (42" [106.68cm] HIGH) 30" DIA. ROUND TABLE [76.2cm D!/ ,.] (18" [45.7cm] HIGH) WITH 2- UPHOLSTERED CHAIRS 26" X 26" [66cm X 66cm] FRAMED WALL ART NOTE: VERTICAL WALL ART CAN NOT BE USED ABOVE BANQUETTE WALL BENCH SEATING. QUEST CHAIR 6" [15.2cm] COUNTER TOP HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND QUEST CHAIR BANQUETTE WALL BENCH BANQUETTE WALL BENCH QUENTIN WALL COVERING COVEBASE OR BULLNOSE N M NO CHAIR RAIL MOLDING INSTALLED FOR ENTIRE LENTGH OF BANQUETTE WALL BENCHES E U M (0 MANUFACTURER - PLYMOLD UPHOLSTERED FABRIC COVERED. AVAILABLE COLORS: STINSON GRAND SIERRA -BLACK (363492) OR MORBERN CARRARA - BUCK(TUSCAN BROWN). OPTIONAL FABRIC SEAT PAD OR BANQUETTE BACK PAD: STINSON (70006) MANUFACTURER - PLYMOLD COUNTER TOP COLOR: FONT HILL PEAR (WILSONART #10745 -60) WITH BLACK DURA -EDGE 12" CANTILEVER. MINIMUM TWO CANTILEVERS PER COUNTER TOP. FRAME FINISH COLOR: BLACK WRINKLE 5/8" DRYWALL 2" X 4" WOOD OR METAL FRAMING 28" [71.1cm] SIDE ELEVATION L QUEST BAR HEIGHT STOOL 10 1/4" [26cm] W 1- ¢¢ E ct 0 J C 0 3 u N 10 1/4 [26cm] QUENTIN WALL COVERING COVEBASE OR BULLNOSE / N FRONT ELEVATION BANQUETTE WALL BENCH ARMCHAIR UPHOLSTERED FURNITURE iill�iiiililllli iililiii II iiiiiilliililli fil CANTILEVER INSTALLATION 20" X 24" TABLE [50.8cm X 61cm] (30" [76.2cm] HIGH) QUEST CHAIR SIDE ELEVATION - FULL HEIGHT WALL INSTALLATION 6" [15.2cm] COUNTER TOP HARDWOOD PLANK WITH ROUTED EDGES (STAINED MINWAX #235 CHERRY AND POLYURETHANED WITH MINWAX FAST DRYING CLEAR SATIN) BANQUETTE WALL BENCH 20" X 24" TABLE [50.8cm X 61cm] (30" [76.2cm] HIGH) N QUEST CHAIR SIDE ELEVATION - 48" HIGH DIVIDER WALL INSTALLATION O M E U N (O N QUEST CHAIR - 12" CANTILEVER BRACKETS COUNTER TOP SEATING N LOVESEAT MANUFACTURER - PLYMOLD TABLE TOP COLOR: FONT HILL PEAR (WILSONART #10745 -60) WITH BLACK DURA -EDGE PLYMOLD BOLT -DOWN TABLE BASE HAS 3" COLUMN. FRAME FINISH COLOR: BLACK WRINKLE QUEST BAR HEIGHT STOOL - WINDOW FRONT ELEVATION BOLT -DOWN INSTALLATION COUCH 28 3/4" [73cm] SUPPORT FOR 30" HEIGHT. 40 3/4" [103.5cm] SUPPORT FOR 42" HEIGHT. BOLT -DOWN TABLE BASE QUEST CHAIR REVIEWED FOR CODE COMPLIANCE APPROVED MAR 1 2 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKIMLA FEB Q 2 1009 ERMIT CENTER U N (p N STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ( "DAI ") D /B /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND /OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAPS AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAPS STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. REVISION: m W Q 0 SHEET #: 2of4 ©2008 DOCTORS ASSOCIATES, INC. SIZE INLET/ OUTLET SIZE FLOW RATE G.P.M. [L.P.M.] CAPACITY APPROX. WT. LBS. [KG] DIMENSIONS IN INCHES [mm] WATER GAL. [L] GREASE LBS. [KG] C C/E F G 100* 2 [50] 4 [15] 3 [11] 8 [4] 42 [19] 10 [254] 7 1/4 [184] 20 3/8 [518] 9 7/8 [251] 200* 7 [26] 5 [19] 14 [6] 53 [24] 11 1/4 [286] 8 1/8 [206] 21 3/4 [552] 11 7/8 [302] 300* 10 [38] 6 [23] 20 [9] 66 [30] 11 3/4 [298] 8 1/4 [210] 25 1/8 [638] 14 [356] 400* 3 [75] 15 [57] 10 [38] 30 [14] 83 [38] 13 3/8 [340] 9 3/8 [238] 27 1/8 [689] 16 3/4 [425] 500 20 [76] 16 [60] 40 [18] 99 [45] 15 [381] 11 3/4 [298] 30 [762] 17 1/4 [438] 600 25 [94] 21 [79] 50 [23] 124 [56] 17 [432] 12 1/2 [318] 32 1/4 [819] 19 7/8 [505] 700 35 [132] 30 [113] 70 [32] 151 [68] 18 3/4 [476] 14 1/4 [362] 34 1/8 [867] 22 1/2 [572] 800 50 [189] 40 [151] 100 [45] 180 [82] 21 1/2 [546] 16 [406] 36 [914] 24 1/2 [622 NHL # VOLTS /HZ /PH AMPS. I TE RIOR NR241 SSS /0 115/60/1 8.6 22.5 NR522SSS /0 115/60/1 10.7 48.8 NR803SSS /8 208- 230/60/1 8.3 75.0 NF241 SSS /0 115/60/1 12 22.5 NF522SSS /0 115/60/1 12.4 48.8 NF803SSS /8 208 - 230/60/1 7.8 75.0 DATE: 10 -31 -08 DESIGNED BY: PATRICK ROSE DRAWN BY: REVIEWED BY: PMR PMR SCALE: NOT TO SCALE MODEL # KLB45 -CX -SUB A 4 (121.9cm) 4' (121.9cm) 5' (152.4cm) 6' (182.9cm) 8' (243.8cm) 4' (121.9cm) 6' (182.9cm) 8' (243.8cm) 5 ' (152.4cm) 6' (182.9cm) 6 ' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' • (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 8' (243.8cm) 5' (152.4cm) 6' (182.9cm) 6' (182.9cm) 6 ' (182.9cm) 6 ' (182.9cm) (66c 26" (66cm) (66cm) 26" (66cm) (66c 26" (66cm) 26" (66cm) 26" 78" (66cm) (198.1cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 59" (149.9cm) (167 6cm) (167.6cm) 6cm) 66" (167.6cm) 66" (167.6cm) 66" (167.6cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 8' (198.1cm) 78" (198.1 cm) 59" (149.9cm) 66" (167.6cm) (167.6cm) 6cm) 66" (167.6cm) 66" (167.6cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37 14 7/8" (37.7cm) INTERIOR Cu. FT. 77 MINIMUM CIRCUIT AMPS 11.9 13.4 13.4 DEFROST 13.4 13.4 DEFROST 13.4 13.4 DEFROST 13.4 13.4 DEFROST 8.8 10.8 DEFROST TOTAL SYSTEM AMPS 11.7 MA FUSE SIZE 20 rr 11InKIS 7��E 1 1[ r 1 NMI 71 li ■■if•r� - �1r - -- -MI ■ IMOM - - 11rrs■11 --- ■MIa -__- r I lrr ire rl ll I = = == L Jl 1E 11 MIL 111111 - - -- I - 11 "7I 1r[ it In& N lel NMI im � rir1 I 1 I► I 1 1I 7 I f ,l ]11 r . - [ -�1_ =I I IT - 1 1 l �.'�r r[ ll lUrl 7l 11 IN 71 AM Vii_ *'..- MEMIrrMEfrMN -NMI r Ell MIMrlal MMEMrr =t'r • 1 f 'WI _7 ■ i mm. ■ i ■ ...[--ii 11 lrMI ra1111 ■ 1x1 [ it - 11 11 7r - 711< 111111 MS 111111111111111111111 MI II 769.9cm P NORLAKE KOLD LOCKER SERIES REFRIGERATOR AND FREEZER LEFT END 0 O r') 0) o- w In cc t) E 0 u E 0 N N N 0 up. co u 1/ " J 44 .4 MODEL NR803SSS /8 OR NF803SSS /8 SHOWN NORLAKE REFRIGERATOR / FREEZER E O O O M ' \ 16 3/16" [41.1 cmT� E 0 O O 21 1/2" [54.6cm] DEPTH 18" TYP. MODEL: CA60 -RR25 HOLDS 25 HALF SIZE PANS (13" X 18 ") MODEL: CA76 -RR33 HOLDS 33 HALF SIZE PANS (13" X 18 ") *CA76 -RR33 TO BE USED WITH 77 SERIES REFRIGERATOR. ALUMINUM WELDED CONSTRUCTION NSF APPROVED LOCKWOOD RETARDER CABINET 11 82 1/2" [209.6cm] (2 DOOR NR482/NF482 - 55" [139.7cm]) (1 DOOR NR241/NF241 - 27 1/2' [69.9cm]) 84" [ 213.4cm] 16" TYP. ALL SYSTEMS - CORD & PLUG SUPPLIED NSF APPROVED UL LISTING #SA -3931 CSA LISTING 18542 -23 [45.7cm] l [40.6cm J ELEVATION PLAN VIEW ELEVATION THREE COMPARTMENT SINK WITH TWO 16" DRAINBOARDS SHOWN ABOVE. AVAILABLE WITH ONE, TWO, THREE OR FOUR COMPARTMENTS AND ZERO, ONE OR TWO 18 "[45.7cm], 24161cm] OR 30 "[76.2cm] DRAINBOARDS. THREE COMPARTMENT CORNER SINKS ALSO AVAILABLE. 1/2" NPT WATER LINES. 2" DRAINS. UL AND C -UL LISTED. DUKE MANUFACTURING STAINLESS STEEL SINK 36 "[91.4cm] TO 120 "[304.8crn] IN 12 "[30.5cm] INCREMENTS SEE BELOW t 0 0) AVAILABLE SIZES ARE: WIDTH: 14 ", 18 ", 21", 24" (35.6, 45.7, 53.3, 61 cm LENGTH: 24', 30 ", 36 ", 42 ", 48 ", 60" AND 72" (61, 76.2, 91.4, 106.7, 121.9, 152.4, 182.9cm) 4 OR 5 TIER INTERMETRO SHELVING SYSTEMS WITH GALVANIZED UNDERSHELF TABLES 96" AND LARGER HAVE SIX LEGS DRAWERS ARE OPTIONAL NSF APPROVED 30" [76.2cm] RIGHT END 1 DUKE STAINLESS STEEL WORKTABLE 30" [76.2cm] 24 1/2" [62.2cm] 34" [86.4cm] 4- ICE0520 CUBER ON B42 STORAGE BIN (374 LBS. STORAGE CAPACITY) AIR - COOLED OR WATER COOLED. ELECTRICAL SPECIFICATIONS: DIRECT WIRED PER CODE (3 WIRES) AIR - COOLED: 115V/60HZ/1PH 18.3 AMPS (20 MAX FUSE) 8441 BTUH. WATER- COOLED: 115V/60HZ/1PH 13.5 AMPS (15 MAX FUSE) 8356 BTUH. PLUMBING SPECIFICATIONS: 3/8" 10mm FPT WATER IN 3/4" 19mm FPT WATER OUT 3/4" 19mm FPT BIN DRAIN 3/8" (19m FPT CONDENSER WATER IN 1/2" (13mm) FPT CONDENSER WATER OUT NSF/ UL APPROVED ICE -O -MATIC ICE CUBER E 0 03 (0 (0 E 0 N to Q -420 CUBER ON S -420 BIN TYPE: AIR - COOLED, WATER- COOLED ELECTRICAL SPECIFICATIONS 115/60/1 20 AMP FUSE MIN. AIR - COALED = 12.3 AMPS, WATER- COOLED = 11.4 AMPS WIRED DIRECT OR PER LOCAL CODE 220 - 240/50/1 ALSO AVAILABLE, SEE MANUFACTURER. PLUMBING SPECIFICATIONS 3/8" (0.95cm) F.P.T. INLET, 1/2" (1.27cm) F.P.T. DRAIN 3/4" (1.91cm) BIN DRAIN 3/8" (0.95cm) F.P,T. WATER CONDENSER INLET (WATER - COOLED UNIT) 1/2" (1.27cm) F.P.T. WATER CONDENSER OUTLET (WATER - COOLED UNIT) NSF APPROVED /U.L. #SA- 4027 /CSA LISTED MANITOWOC ICE CUBER GREASE INTERCEPTOR MANUFACTURER: ZURN INDUSTRIES MODEL: Z1170 = WIDTH OF BODY F 24" [61.0cm] 31" [78.7cm] 0 0 aD 0 Lto E 0 u (0 ICE0400 CUBER (AIR - COOLED OR WATER - COOLED) ICE0500 CUBER (AIR- COOLED, WATER - COOLED OR REMOTE CONDENSER) ICE0606 CUBER (AIR- COOLED, WATER- COOLED OR REMOTE CONDENSER) ON B55 STORAGE BIN (556 LBS. STORAGE CAPACITY) ELECTRICAL SPECIFICATIONS: DIRECT WIRED PER CODE (3 WIRES) ICE0400: (AIR - COOLED) 115V/60HZ/1PH 14.4 AMPS (15 MAX FUSE) 8064 BTUH. (WATER- COOLED) 115V/60HZ/1PH 13.4 AMPS (20 MAX FUSE) 8388 BTUH. ICE0500: (AIR - COOLED) 115V/60HZ/1PH 19.9 AMPS (20 MAX FUSE) 10843 BTUH. (R (WATER-COOLED) 115V /60HZ /1PH 13.7 AMPS (20 MAXFUSE) 10242 BTUH. EMOTE) 115V/60HZ/1PH 18.7 AMPS (20 MAX FUSE) 10881 BTUH. ICE0606: (AIR - COOLED) 208- 230V/60HZ/1PH 12 AMPS (15 MAX FUSE)11538 BTUH. (R (WATER-COOLED) 208- 230V /60HZ /1PH 9.5 AMPS (15 MAX FUSE) 11473 BTUH. EMOTE) 208- 230V /60HZ /1PH 13 AMPS (15 MAX FUSE) 12269 BTUH. PLUMBING SPECIFICATIONS: 3/8" 10mm FPT WATER IN 3/4" 19mm FPT WATER OUT 3/4" 19mm FPT BIN DRAIN (WATER - COOLED UNIT CONDENSER LINES): 3/8" (19mm) FPT CONDENSER WATER IN 1/2" (13mm) FPT CONDENSER WATER OUT NSF/ UL APPROVED ICE -O -MATIC ICE CUBER ZURN GREASE INTERCEPTOR 2°. [76.2cm] Q -450 CUBER ON S -400 BIN TYPE: AIR - COOLED, WATER - COOLED, REMOTE. ELECTRICAL SPECIFICATIONS 115/60/1 20 AMP FUSE MIN. AIR - COOLED = 12.8 AMPS, WATER - COOLED = 11.9 AMPS REMOTE = 9.6 AMPS WIRED DIRECT OR PER LOCAL CODE 220 - 240/50/1 ALSO AVAILABLE, SEE MANUFACTURER. PLUMBING SPECIFICATIONS 3/8" (0.95cm) F.P.T. INLET, 1/2" (1.27cm) F.P.T. DRAIN 3/4" (1.91 cm) BIN DRAIN 3/8" (0.95cm) F.P.T. WATER CONDENSER INLET (WATER - COOLED UNIT) 1/2" (1.27cm) F.P.T. WATER CONDENSER OUTLET (WATER - COOLED UNIT) NSF APPROVED /U.L. #SA- 4027 /CSA LISTED MANITOWOC ICE CUBER \ REVIEWED FOR CODE COMPLIANCE APPROVED MAR 12 2009 City of Tukwila BUILDING DIVISION CITY FEB 02 2009 PERMIT CENTER *100, 200, 300 AND 400 ARE STANDARD SUBWAY MODEL SIZES. ENGINEERING SPECIFICATIONS: ACID RESISTANT COATED INTERIOR AND EXTERIOR FABRICATED STEEL. INTERNAL AIR RELIEF BYPASS. BRONZE CLEANOUT PLUG. REMOVABLE PRESSURE EQUALIZING /FLOW DIFFUSING INLET BAFFLE. FIXED BOTTOM OUTLET BAFFLE. VISIBLE DOUBLE WALL TRAP SEAL. NOTE: THESE DRAWINGS REPRESENT TYPICAL EQUIPMENT PURCHASED THROUGH DOCTOR'S ASSOCIATES INC. AND DOES NOT REPRESENT ANY EQUIPMENT PURCHASED LOCALLY BY THE FRANCHISEE/OWNER. OWNERS OF STORES OUTSIDE THE UNITED STATES AND CANADA MAY NEED ALTERNATE ELECTRICAL REQUIREMENTS. CONTACT YOUR DAI COORDINATOR OR THE MANUFACTURER FOR THE MODIFIED ELECTRICAL SPECIFICATIONS. STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ( "DAI ") D /B /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND /OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAI'S AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAPS STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. REVISION: m w 0 SHEET #: 30f4 ©2008 DOCTORS ASSOCIATES, INC. I Iv NHL # VOLTS /HZ /PH AMPS. I TE RIOR NR241 SSS /0 115/60/1 8.6 22.5 NR522SSS /0 115/60/1 10.7 48.8 NR803SSS /8 208- 230/60/1 8.3 75.0 NF241 SSS /0 115/60/1 12 22.5 NF522SSS /0 115/60/1 12.4 48.8 NF803SSS /8 208 - 230/60/1 7.8 75.0 DATE: 10 -31 -08 DESIGNED BY: PATRICK ROSE DRAWN BY: REVIEWED BY: PMR PMR SCALE: NOT TO SCALE MODEL # KLB45 -CX -SUB A 4 (121.9cm) 4' (121.9cm) 5' (152.4cm) 6' (182.9cm) 8' (243.8cm) 4' (121.9cm) 6' (182.9cm) 8' (243.8cm) 5 ' (152.4cm) 6' (182.9cm) 6 ' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' • (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 8' (243.8cm) 5' (152.4cm) 6' (182.9cm) 6' (182.9cm) 6 ' (182.9cm) 6 ' (182.9cm) (66c 26" (66cm) (66cm) 26" (66cm) (66c 26" (66cm) 26" (66cm) 26" 78" (66cm) (198.1cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 59" (149.9cm) (167 6cm) (167.6cm) 6cm) 66" (167.6cm) 66" (167.6cm) 66" (167.6cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 8' (198.1cm) 78" (198.1 cm) 59" (149.9cm) 66" (167.6cm) (167.6cm) 6cm) 66" (167.6cm) 66" (167.6cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37 14 7/8" (37.7cm) INTERIOR Cu. FT. 77 MINIMUM CIRCUIT AMPS 11.9 13.4 13.4 DEFROST 13.4 13.4 DEFROST 13.4 13.4 DEFROST 13.4 13.4 DEFROST 8.8 10.8 DEFROST TOTAL SYSTEM AMPS 11.7 MA FUSE SIZE 20 rr 11InKIS 7��E 1 1[ r 1 NMI 71 li ■■if•r� - �1r - -- -MI ■ IMOM - - 11rrs■11 --- ■MIa -__- r I lrr ire rl ll I = = == L Jl 1E 11 MIL 111111 - - -- I - 11 "7I 1r[ it In& N lel NMI im � rir1 I 1 I► I 1 1I 7 I f ,l ]11 r . - [ -�1_ =I I IT - 1 1 l �.'�r r[ ll lUrl 7l 11 IN 71 AM Vii_ *'..- MEMIrrMEfrMN -NMI r Ell MIMrlal MMEMrr =t'r • 1 f 'WI _7 ■ i mm. ■ i ■ ...[--ii 11 lrMI ra1111 ■ 1x1 [ it - 11 11 7r - 711< 111111 MS 111111111111111111111 MI II 769.9cm P NORLAKE KOLD LOCKER SERIES REFRIGERATOR AND FREEZER LEFT END 0 O r') 0) o- w In cc t) E 0 u E 0 N N N 0 up. co u 1/ " J 44 .4 MODEL NR803SSS /8 OR NF803SSS /8 SHOWN NORLAKE REFRIGERATOR / FREEZER E O O O M ' \ 16 3/16" [41.1 cmT� E 0 O O 21 1/2" [54.6cm] DEPTH 18" TYP. MODEL: CA60 -RR25 HOLDS 25 HALF SIZE PANS (13" X 18 ") MODEL: CA76 -RR33 HOLDS 33 HALF SIZE PANS (13" X 18 ") *CA76 -RR33 TO BE USED WITH 77 SERIES REFRIGERATOR. ALUMINUM WELDED CONSTRUCTION NSF APPROVED LOCKWOOD RETARDER CABINET 11 82 1/2" [209.6cm] (2 DOOR NR482/NF482 - 55" [139.7cm]) (1 DOOR NR241/NF241 - 27 1/2' [69.9cm]) 84" [ 213.4cm] 16" TYP. ALL SYSTEMS - CORD & PLUG SUPPLIED NSF APPROVED UL LISTING #SA -3931 CSA LISTING 18542 -23 [45.7cm] l [40.6cm J ELEVATION PLAN VIEW ELEVATION THREE COMPARTMENT SINK WITH TWO 16" DRAINBOARDS SHOWN ABOVE. AVAILABLE WITH ONE, TWO, THREE OR FOUR COMPARTMENTS AND ZERO, ONE OR TWO 18 "[45.7cm], 24161cm] OR 30 "[76.2cm] DRAINBOARDS. THREE COMPARTMENT CORNER SINKS ALSO AVAILABLE. 1/2" NPT WATER LINES. 2" DRAINS. UL AND C -UL LISTED. DUKE MANUFACTURING STAINLESS STEEL SINK 36 "[91.4cm] TO 120 "[304.8crn] IN 12 "[30.5cm] INCREMENTS SEE BELOW t 0 0) AVAILABLE SIZES ARE: WIDTH: 14 ", 18 ", 21", 24" (35.6, 45.7, 53.3, 61 cm LENGTH: 24', 30 ", 36 ", 42 ", 48 ", 60" AND 72" (61, 76.2, 91.4, 106.7, 121.9, 152.4, 182.9cm) 4 OR 5 TIER INTERMETRO SHELVING SYSTEMS WITH GALVANIZED UNDERSHELF TABLES 96" AND LARGER HAVE SIX LEGS DRAWERS ARE OPTIONAL NSF APPROVED 30" [76.2cm] RIGHT END 1 DUKE STAINLESS STEEL WORKTABLE 30" [76.2cm] 24 1/2" [62.2cm] 34" [86.4cm] 4- ICE0520 CUBER ON B42 STORAGE BIN (374 LBS. STORAGE CAPACITY) AIR - COOLED OR WATER COOLED. ELECTRICAL SPECIFICATIONS: DIRECT WIRED PER CODE (3 WIRES) AIR - COOLED: 115V/60HZ/1PH 18.3 AMPS (20 MAX FUSE) 8441 BTUH. WATER- COOLED: 115V/60HZ/1PH 13.5 AMPS (15 MAX FUSE) 8356 BTUH. PLUMBING SPECIFICATIONS: 3/8" 10mm FPT WATER IN 3/4" 19mm FPT WATER OUT 3/4" 19mm FPT BIN DRAIN 3/8" (19m FPT CONDENSER WATER IN 1/2" (13mm) FPT CONDENSER WATER OUT NSF/ UL APPROVED ICE -O -MATIC ICE CUBER E 0 03 (0 (0 E 0 N to Q -420 CUBER ON S -420 BIN TYPE: AIR - COOLED, WATER- COOLED ELECTRICAL SPECIFICATIONS 115/60/1 20 AMP FUSE MIN. AIR - COALED = 12.3 AMPS, WATER- COOLED = 11.4 AMPS WIRED DIRECT OR PER LOCAL CODE 220 - 240/50/1 ALSO AVAILABLE, SEE MANUFACTURER. PLUMBING SPECIFICATIONS 3/8" (0.95cm) F.P.T. INLET, 1/2" (1.27cm) F.P.T. DRAIN 3/4" (1.91cm) BIN DRAIN 3/8" (0.95cm) F.P,T. WATER CONDENSER INLET (WATER - COOLED UNIT) 1/2" (1.27cm) F.P.T. WATER CONDENSER OUTLET (WATER - COOLED UNIT) NSF APPROVED /U.L. #SA- 4027 /CSA LISTED MANITOWOC ICE CUBER GREASE INTERCEPTOR MANUFACTURER: ZURN INDUSTRIES MODEL: Z1170 = WIDTH OF BODY F 24" [61.0cm] 31" [78.7cm] 0 0 aD 0 Lto E 0 u (0 ICE0400 CUBER (AIR - COOLED OR WATER - COOLED) ICE0500 CUBER (AIR- COOLED, WATER - COOLED OR REMOTE CONDENSER) ICE0606 CUBER (AIR- COOLED, WATER- COOLED OR REMOTE CONDENSER) ON B55 STORAGE BIN (556 LBS. STORAGE CAPACITY) ELECTRICAL SPECIFICATIONS: DIRECT WIRED PER CODE (3 WIRES) ICE0400: (AIR - COOLED) 115V/60HZ/1PH 14.4 AMPS (15 MAX FUSE) 8064 BTUH. (WATER- COOLED) 115V/60HZ/1PH 13.4 AMPS (20 MAX FUSE) 8388 BTUH. ICE0500: (AIR - COOLED) 115V/60HZ/1PH 19.9 AMPS (20 MAX FUSE) 10843 BTUH. (R (WATER-COOLED) 115V /60HZ /1PH 13.7 AMPS (20 MAXFUSE) 10242 BTUH. EMOTE) 115V/60HZ/1PH 18.7 AMPS (20 MAX FUSE) 10881 BTUH. ICE0606: (AIR - COOLED) 208- 230V/60HZ/1PH 12 AMPS (15 MAX FUSE)11538 BTUH. (R (WATER-COOLED) 208- 230V /60HZ /1PH 9.5 AMPS (15 MAX FUSE) 11473 BTUH. EMOTE) 208- 230V /60HZ /1PH 13 AMPS (15 MAX FUSE) 12269 BTUH. PLUMBING SPECIFICATIONS: 3/8" 10mm FPT WATER IN 3/4" 19mm FPT WATER OUT 3/4" 19mm FPT BIN DRAIN (WATER - COOLED UNIT CONDENSER LINES): 3/8" (19mm) FPT CONDENSER WATER IN 1/2" (13mm) FPT CONDENSER WATER OUT NSF/ UL APPROVED ICE -O -MATIC ICE CUBER ZURN GREASE INTERCEPTOR 2°. [76.2cm] Q -450 CUBER ON S -400 BIN TYPE: AIR - COOLED, WATER - COOLED, REMOTE. ELECTRICAL SPECIFICATIONS 115/60/1 20 AMP FUSE MIN. AIR - COOLED = 12.8 AMPS, WATER - COOLED = 11.9 AMPS REMOTE = 9.6 AMPS WIRED DIRECT OR PER LOCAL CODE 220 - 240/50/1 ALSO AVAILABLE, SEE MANUFACTURER. PLUMBING SPECIFICATIONS 3/8" (0.95cm) F.P.T. INLET, 1/2" (1.27cm) F.P.T. DRAIN 3/4" (1.91 cm) BIN DRAIN 3/8" (0.95cm) F.P.T. WATER CONDENSER INLET (WATER - COOLED UNIT) 1/2" (1.27cm) F.P.T. WATER CONDENSER OUTLET (WATER - COOLED UNIT) NSF APPROVED /U.L. #SA- 4027 /CSA LISTED MANITOWOC ICE CUBER \ REVIEWED FOR CODE COMPLIANCE APPROVED MAR 12 2009 City of Tukwila BUILDING DIVISION CITY FEB 02 2009 PERMIT CENTER *100, 200, 300 AND 400 ARE STANDARD SUBWAY MODEL SIZES. ENGINEERING SPECIFICATIONS: ACID RESISTANT COATED INTERIOR AND EXTERIOR FABRICATED STEEL. INTERNAL AIR RELIEF BYPASS. BRONZE CLEANOUT PLUG. REMOVABLE PRESSURE EQUALIZING /FLOW DIFFUSING INLET BAFFLE. FIXED BOTTOM OUTLET BAFFLE. VISIBLE DOUBLE WALL TRAP SEAL. NOTE: THESE DRAWINGS REPRESENT TYPICAL EQUIPMENT PURCHASED THROUGH DOCTOR'S ASSOCIATES INC. AND DOES NOT REPRESENT ANY EQUIPMENT PURCHASED LOCALLY BY THE FRANCHISEE/OWNER. OWNERS OF STORES OUTSIDE THE UNITED STATES AND CANADA MAY NEED ALTERNATE ELECTRICAL REQUIREMENTS. CONTACT YOUR DAI COORDINATOR OR THE MANUFACTURER FOR THE MODIFIED ELECTRICAL SPECIFICATIONS. STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ( "DAI ") D /B /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND /OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAI'S AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAPS STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. REVISION: m w 0 SHEET #: 30f4 ©2008 DOCTORS ASSOCIATES, INC. DATE: 10 -31 -08 DESIGNED BY: PATRICK ROSE DRAWN BY: REVIEWED BY: PMR PMR SCALE: NOT TO SCALE MODEL # KLB45 -CX -SUB A 4 (121.9cm) 4' (121.9cm) 5' (152.4cm) 6' (182.9cm) 8' (243.8cm) 4' (121.9cm) 6' (182.9cm) 8' (243.8cm) 5 ' (152.4cm) 6' (182.9cm) 6 ' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' • (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 8' (243.8cm) 5' (152.4cm) 6' (182.9cm) 6' (182.9cm) 6 ' (182.9cm) 6 ' (182.9cm) (66c 26" (66cm) (66cm) 26" (66cm) (66c 26" (66cm) 26" (66cm) 26" 78" (66cm) (198.1cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 59" (149.9cm) (167 6cm) (167.6cm) 6cm) 66" (167.6cm) 66" (167.6cm) 66" (167.6cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 8' (198.1cm) 78" (198.1 cm) 59" (149.9cm) 66" (167.6cm) (167.6cm) 6cm) 66" (167.6cm) 66" (167.6cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37 14 7/8" (37.7cm) INTERIOR Cu. FT. 77 MINIMUM CIRCUIT AMPS 11.9 13.4 13.4 DEFROST 13.4 13.4 DEFROST 13.4 13.4 DEFROST 13.4 13.4 DEFROST 8.8 10.8 DEFROST TOTAL SYSTEM AMPS 11.7 MA FUSE SIZE 20 rr 11InKIS 7��E 1 1[ r 1 NMI 71 li ■■if•r� - �1r - -- -MI ■ IMOM - - 11rrs■11 --- ■MIa -__- r I lrr ire rl ll I = = == L Jl 1E 11 MIL 111111 - - -- I - 11 "7I 1r[ it In& N lel NMI im � rir1 I 1 I► I 1 1I 7 I f ,l ]11 r . - [ -�1_ =I I IT - 1 1 l �.'�r r[ ll lUrl 7l 11 IN 71 AM Vii_ *'..- MEMIrrMEfrMN -NMI r Ell MIMrlal MMEMrr =t'r • 1 f 'WI _7 ■ i mm. ■ i ■ ...[--ii 11 lrMI ra1111 ■ 1x1 [ it - 11 11 7r - 711< 111111 MS 111111111111111111111 MI II 769.9cm P NORLAKE KOLD LOCKER SERIES REFRIGERATOR AND FREEZER LEFT END 0 O r') 0) o- w In cc t) E 0 u E 0 N N N 0 up. co u 1/ " J 44 .4 MODEL NR803SSS /8 OR NF803SSS /8 SHOWN NORLAKE REFRIGERATOR / FREEZER E O O O M ' \ 16 3/16" [41.1 cmT� E 0 O O 21 1/2" [54.6cm] DEPTH 18" TYP. MODEL: CA60 -RR25 HOLDS 25 HALF SIZE PANS (13" X 18 ") MODEL: CA76 -RR33 HOLDS 33 HALF SIZE PANS (13" X 18 ") *CA76 -RR33 TO BE USED WITH 77 SERIES REFRIGERATOR. ALUMINUM WELDED CONSTRUCTION NSF APPROVED LOCKWOOD RETARDER CABINET 11 82 1/2" [209.6cm] (2 DOOR NR482/NF482 - 55" [139.7cm]) (1 DOOR NR241/NF241 - 27 1/2' [69.9cm]) 84" [ 213.4cm] 16" TYP. ALL SYSTEMS - CORD & PLUG SUPPLIED NSF APPROVED UL LISTING #SA -3931 CSA LISTING 18542 -23 [45.7cm] l [40.6cm J ELEVATION PLAN VIEW ELEVATION THREE COMPARTMENT SINK WITH TWO 16" DRAINBOARDS SHOWN ABOVE. AVAILABLE WITH ONE, TWO, THREE OR FOUR COMPARTMENTS AND ZERO, ONE OR TWO 18 "[45.7cm], 24161cm] OR 30 "[76.2cm] DRAINBOARDS. THREE COMPARTMENT CORNER SINKS ALSO AVAILABLE. 1/2" NPT WATER LINES. 2" DRAINS. UL AND C -UL LISTED. DUKE MANUFACTURING STAINLESS STEEL SINK 36 "[91.4cm] TO 120 "[304.8crn] IN 12 "[30.5cm] INCREMENTS SEE BELOW t 0 0) AVAILABLE SIZES ARE: WIDTH: 14 ", 18 ", 21", 24" (35.6, 45.7, 53.3, 61 cm LENGTH: 24', 30 ", 36 ", 42 ", 48 ", 60" AND 72" (61, 76.2, 91.4, 106.7, 121.9, 152.4, 182.9cm) 4 OR 5 TIER INTERMETRO SHELVING SYSTEMS WITH GALVANIZED UNDERSHELF TABLES 96" AND LARGER HAVE SIX LEGS DRAWERS ARE OPTIONAL NSF APPROVED 30" [76.2cm] RIGHT END 1 DUKE STAINLESS STEEL WORKTABLE 30" [76.2cm] 24 1/2" [62.2cm] 34" [86.4cm] 4- ICE0520 CUBER ON B42 STORAGE BIN (374 LBS. STORAGE CAPACITY) AIR - COOLED OR WATER COOLED. ELECTRICAL SPECIFICATIONS: DIRECT WIRED PER CODE (3 WIRES) AIR - COOLED: 115V/60HZ/1PH 18.3 AMPS (20 MAX FUSE) 8441 BTUH. WATER- COOLED: 115V/60HZ/1PH 13.5 AMPS (15 MAX FUSE) 8356 BTUH. PLUMBING SPECIFICATIONS: 3/8" 10mm FPT WATER IN 3/4" 19mm FPT WATER OUT 3/4" 19mm FPT BIN DRAIN 3/8" (19m FPT CONDENSER WATER IN 1/2" (13mm) FPT CONDENSER WATER OUT NSF/ UL APPROVED ICE -O -MATIC ICE CUBER E 0 03 (0 (0 E 0 N to Q -420 CUBER ON S -420 BIN TYPE: AIR - COOLED, WATER- COOLED ELECTRICAL SPECIFICATIONS 115/60/1 20 AMP FUSE MIN. AIR - COALED = 12.3 AMPS, WATER- COOLED = 11.4 AMPS WIRED DIRECT OR PER LOCAL CODE 220 - 240/50/1 ALSO AVAILABLE, SEE MANUFACTURER. PLUMBING SPECIFICATIONS 3/8" (0.95cm) F.P.T. INLET, 1/2" (1.27cm) F.P.T. DRAIN 3/4" (1.91cm) BIN DRAIN 3/8" (0.95cm) F.P,T. WATER CONDENSER INLET (WATER - COOLED UNIT) 1/2" (1.27cm) F.P.T. WATER CONDENSER OUTLET (WATER - COOLED UNIT) NSF APPROVED /U.L. #SA- 4027 /CSA LISTED MANITOWOC ICE CUBER GREASE INTERCEPTOR MANUFACTURER: ZURN INDUSTRIES MODEL: Z1170 = WIDTH OF BODY F 24" [61.0cm] 31" [78.7cm] 0 0 aD 0 Lto E 0 u (0 ICE0400 CUBER (AIR - COOLED OR WATER - COOLED) ICE0500 CUBER (AIR- COOLED, WATER - COOLED OR REMOTE CONDENSER) ICE0606 CUBER (AIR- COOLED, WATER- COOLED OR REMOTE CONDENSER) ON B55 STORAGE BIN (556 LBS. STORAGE CAPACITY) ELECTRICAL SPECIFICATIONS: DIRECT WIRED PER CODE (3 WIRES) ICE0400: (AIR - COOLED) 115V/60HZ/1PH 14.4 AMPS (15 MAX FUSE) 8064 BTUH. (WATER- COOLED) 115V/60HZ/1PH 13.4 AMPS (20 MAX FUSE) 8388 BTUH. ICE0500: (AIR - COOLED) 115V/60HZ/1PH 19.9 AMPS (20 MAX FUSE) 10843 BTUH. (R (WATER-COOLED) 115V /60HZ /1PH 13.7 AMPS (20 MAXFUSE) 10242 BTUH. EMOTE) 115V/60HZ/1PH 18.7 AMPS (20 MAX FUSE) 10881 BTUH. ICE0606: (AIR - COOLED) 208- 230V/60HZ/1PH 12 AMPS (15 MAX FUSE)11538 BTUH. (R (WATER-COOLED) 208- 230V /60HZ /1PH 9.5 AMPS (15 MAX FUSE) 11473 BTUH. EMOTE) 208- 230V /60HZ /1PH 13 AMPS (15 MAX FUSE) 12269 BTUH. PLUMBING SPECIFICATIONS: 3/8" 10mm FPT WATER IN 3/4" 19mm FPT WATER OUT 3/4" 19mm FPT BIN DRAIN (WATER - COOLED UNIT CONDENSER LINES): 3/8" (19mm) FPT CONDENSER WATER IN 1/2" (13mm) FPT CONDENSER WATER OUT NSF/ UL APPROVED ICE -O -MATIC ICE CUBER ZURN GREASE INTERCEPTOR 2°. [76.2cm] Q -450 CUBER ON S -400 BIN TYPE: AIR - COOLED, WATER - COOLED, REMOTE. ELECTRICAL SPECIFICATIONS 115/60/1 20 AMP FUSE MIN. AIR - COOLED = 12.8 AMPS, WATER - COOLED = 11.9 AMPS REMOTE = 9.6 AMPS WIRED DIRECT OR PER LOCAL CODE 220 - 240/50/1 ALSO AVAILABLE, SEE MANUFACTURER. PLUMBING SPECIFICATIONS 3/8" (0.95cm) F.P.T. INLET, 1/2" (1.27cm) F.P.T. DRAIN 3/4" (1.91 cm) BIN DRAIN 3/8" (0.95cm) F.P.T. WATER CONDENSER INLET (WATER - COOLED UNIT) 1/2" (1.27cm) F.P.T. WATER CONDENSER OUTLET (WATER - COOLED UNIT) NSF APPROVED /U.L. #SA- 4027 /CSA LISTED MANITOWOC ICE CUBER \ REVIEWED FOR CODE COMPLIANCE APPROVED MAR 12 2009 City of Tukwila BUILDING DIVISION CITY FEB 02 2009 PERMIT CENTER *100, 200, 300 AND 400 ARE STANDARD SUBWAY MODEL SIZES. ENGINEERING SPECIFICATIONS: ACID RESISTANT COATED INTERIOR AND EXTERIOR FABRICATED STEEL. INTERNAL AIR RELIEF BYPASS. BRONZE CLEANOUT PLUG. REMOVABLE PRESSURE EQUALIZING /FLOW DIFFUSING INLET BAFFLE. FIXED BOTTOM OUTLET BAFFLE. VISIBLE DOUBLE WALL TRAP SEAL. NOTE: THESE DRAWINGS REPRESENT TYPICAL EQUIPMENT PURCHASED THROUGH DOCTOR'S ASSOCIATES INC. AND DOES NOT REPRESENT ANY EQUIPMENT PURCHASED LOCALLY BY THE FRANCHISEE/OWNER. OWNERS OF STORES OUTSIDE THE UNITED STATES AND CANADA MAY NEED ALTERNATE ELECTRICAL REQUIREMENTS. CONTACT YOUR DAI COORDINATOR OR THE MANUFACTURER FOR THE MODIFIED ELECTRICAL SPECIFICATIONS. STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ( "DAI ") D /B /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND /OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAI'S AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAPS STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. REVISION: m w 0 SHEET #: 30f4 ©2008 DOCTORS ASSOCIATES, INC. MODEL # KLB45 -CX -SUB A 4 (121.9cm) 4' (121.9cm) 5' (152.4cm) 6' (182.9cm) 8' (243.8cm) 4' (121.9cm) 6' (182.9cm) 8' (243.8cm) 5 ' (152.4cm) 6' (182.9cm) 6 ' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' • (182.9cm) 6' (182.9cm) 6' (182.9cm) 6' (182.9cm) 8' (243.8cm) 5' (152.4cm) 6' (182.9cm) 6' (182.9cm) 6 ' (182.9cm) 6 ' (182.9cm) (66c 26" (66cm) (66cm) 26" (66cm) (66c 26" (66cm) 26" (66cm) 26" 78" (66cm) (198.1cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 26" (66cm) 59" (149.9cm) (167 6cm) (167.6cm) 6cm) 66" (167.6cm) 66" (167.6cm) 66" (167.6cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 78" (198.1cm) 8' (198.1cm) 78" (198.1 cm) 59" (149.9cm) 66" (167.6cm) (167.6cm) 6cm) 66" (167.6cm) 66" (167.6cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37.7cm) 14 7/8" (37 14 7/8" (37.7cm) INTERIOR Cu. FT. 77 MINIMUM CIRCUIT AMPS 11.9 13.4 13.4 DEFROST 13.4 13.4 DEFROST 13.4 13.4 DEFROST 13.4 13.4 DEFROST 8.8 10.8 DEFROST TOTAL SYSTEM AMPS 11.7 MA FUSE SIZE 20 rr 11InKIS 7��E 1 1[ r 1 NMI 71 li ■■if•r� - �1r - -- -MI ■ IMOM - - 11rrs■11 --- ■MIa -__- r I lrr ire rl ll I = = == L Jl 1E 11 MIL 111111 - - -- I - 11 "7I 1r[ it In& N lel NMI im � rir1 I 1 I► I 1 1I 7 I f ,l ]11 r . - [ -�1_ =I I IT - 1 1 l �.'�r r[ ll lUrl 7l 11 IN 71 AM Vii_ *'..- MEMIrrMEfrMN -NMI r Ell MIMrlal MMEMrr =t'r • 1 f 'WI _7 ■ i mm. ■ i ■ ...[--ii 11 lrMI ra1111 ■ 1x1 [ it - 11 11 7r - 711< 111111 MS 111111111111111111111 MI II 769.9cm P NORLAKE KOLD LOCKER SERIES REFRIGERATOR AND FREEZER LEFT END 0 O r') 0) o- w In cc t) E 0 u E 0 N N N 0 up. co u 1/ " J 44 .4 MODEL NR803SSS /8 OR NF803SSS /8 SHOWN NORLAKE REFRIGERATOR / FREEZER E O O O M ' \ 16 3/16" [41.1 cmT� E 0 O O 21 1/2" [54.6cm] DEPTH 18" TYP. MODEL: CA60 -RR25 HOLDS 25 HALF SIZE PANS (13" X 18 ") MODEL: CA76 -RR33 HOLDS 33 HALF SIZE PANS (13" X 18 ") *CA76 -RR33 TO BE USED WITH 77 SERIES REFRIGERATOR. ALUMINUM WELDED CONSTRUCTION NSF APPROVED LOCKWOOD RETARDER CABINET 11 82 1/2" [209.6cm] (2 DOOR NR482/NF482 - 55" [139.7cm]) (1 DOOR NR241/NF241 - 27 1/2' [69.9cm]) 84" [ 213.4cm] 16" TYP. ALL SYSTEMS - CORD & PLUG SUPPLIED NSF APPROVED UL LISTING #SA -3931 CSA LISTING 18542 -23 [45.7cm] l [40.6cm J ELEVATION PLAN VIEW ELEVATION THREE COMPARTMENT SINK WITH TWO 16" DRAINBOARDS SHOWN ABOVE. AVAILABLE WITH ONE, TWO, THREE OR FOUR COMPARTMENTS AND ZERO, ONE OR TWO 18 "[45.7cm], 24161cm] OR 30 "[76.2cm] DRAINBOARDS. THREE COMPARTMENT CORNER SINKS ALSO AVAILABLE. 1/2" NPT WATER LINES. 2" DRAINS. UL AND C -UL LISTED. DUKE MANUFACTURING STAINLESS STEEL SINK 36 "[91.4cm] TO 120 "[304.8crn] IN 12 "[30.5cm] INCREMENTS SEE BELOW t 0 0) AVAILABLE SIZES ARE: WIDTH: 14 ", 18 ", 21", 24" (35.6, 45.7, 53.3, 61 cm LENGTH: 24', 30 ", 36 ", 42 ", 48 ", 60" AND 72" (61, 76.2, 91.4, 106.7, 121.9, 152.4, 182.9cm) 4 OR 5 TIER INTERMETRO SHELVING SYSTEMS WITH GALVANIZED UNDERSHELF TABLES 96" AND LARGER HAVE SIX LEGS DRAWERS ARE OPTIONAL NSF APPROVED 30" [76.2cm] RIGHT END 1 DUKE STAINLESS STEEL WORKTABLE 30" [76.2cm] 24 1/2" [62.2cm] 34" [86.4cm] 4- ICE0520 CUBER ON B42 STORAGE BIN (374 LBS. STORAGE CAPACITY) AIR - COOLED OR WATER COOLED. ELECTRICAL SPECIFICATIONS: DIRECT WIRED PER CODE (3 WIRES) AIR - COOLED: 115V/60HZ/1PH 18.3 AMPS (20 MAX FUSE) 8441 BTUH. WATER- COOLED: 115V/60HZ/1PH 13.5 AMPS (15 MAX FUSE) 8356 BTUH. PLUMBING SPECIFICATIONS: 3/8" 10mm FPT WATER IN 3/4" 19mm FPT WATER OUT 3/4" 19mm FPT BIN DRAIN 3/8" (19m FPT CONDENSER WATER IN 1/2" (13mm) FPT CONDENSER WATER OUT NSF/ UL APPROVED ICE -O -MATIC ICE CUBER E 0 03 (0 (0 E 0 N to Q -420 CUBER ON S -420 BIN TYPE: AIR - COOLED, WATER- COOLED ELECTRICAL SPECIFICATIONS 115/60/1 20 AMP FUSE MIN. AIR - COALED = 12.3 AMPS, WATER- COOLED = 11.4 AMPS WIRED DIRECT OR PER LOCAL CODE 220 - 240/50/1 ALSO AVAILABLE, SEE MANUFACTURER. PLUMBING SPECIFICATIONS 3/8" (0.95cm) F.P.T. INLET, 1/2" (1.27cm) F.P.T. DRAIN 3/4" (1.91cm) BIN DRAIN 3/8" (0.95cm) F.P,T. WATER CONDENSER INLET (WATER - COOLED UNIT) 1/2" (1.27cm) F.P.T. WATER CONDENSER OUTLET (WATER - COOLED UNIT) NSF APPROVED /U.L. #SA- 4027 /CSA LISTED MANITOWOC ICE CUBER GREASE INTERCEPTOR MANUFACTURER: ZURN INDUSTRIES MODEL: Z1170 = WIDTH OF BODY F 24" [61.0cm] 31" [78.7cm] 0 0 aD 0 Lto E 0 u (0 ICE0400 CUBER (AIR - COOLED OR WATER - COOLED) ICE0500 CUBER (AIR- COOLED, WATER - COOLED OR REMOTE CONDENSER) ICE0606 CUBER (AIR- COOLED, WATER- COOLED OR REMOTE CONDENSER) ON B55 STORAGE BIN (556 LBS. STORAGE CAPACITY) ELECTRICAL SPECIFICATIONS: DIRECT WIRED PER CODE (3 WIRES) ICE0400: (AIR - COOLED) 115V/60HZ/1PH 14.4 AMPS (15 MAX FUSE) 8064 BTUH. (WATER- COOLED) 115V/60HZ/1PH 13.4 AMPS (20 MAX FUSE) 8388 BTUH. ICE0500: (AIR - COOLED) 115V/60HZ/1PH 19.9 AMPS (20 MAX FUSE) 10843 BTUH. (R (WATER-COOLED) 115V /60HZ /1PH 13.7 AMPS (20 MAXFUSE) 10242 BTUH. EMOTE) 115V/60HZ/1PH 18.7 AMPS (20 MAX FUSE) 10881 BTUH. ICE0606: (AIR - COOLED) 208- 230V/60HZ/1PH 12 AMPS (15 MAX FUSE)11538 BTUH. (R (WATER-COOLED) 208- 230V /60HZ /1PH 9.5 AMPS (15 MAX FUSE) 11473 BTUH. EMOTE) 208- 230V /60HZ /1PH 13 AMPS (15 MAX FUSE) 12269 BTUH. PLUMBING SPECIFICATIONS: 3/8" 10mm FPT WATER IN 3/4" 19mm FPT WATER OUT 3/4" 19mm FPT BIN DRAIN (WATER - COOLED UNIT CONDENSER LINES): 3/8" (19mm) FPT CONDENSER WATER IN 1/2" (13mm) FPT CONDENSER WATER OUT NSF/ UL APPROVED ICE -O -MATIC ICE CUBER ZURN GREASE INTERCEPTOR 2°. [76.2cm] Q -450 CUBER ON S -400 BIN TYPE: AIR - COOLED, WATER - COOLED, REMOTE. ELECTRICAL SPECIFICATIONS 115/60/1 20 AMP FUSE MIN. AIR - COOLED = 12.8 AMPS, WATER - COOLED = 11.9 AMPS REMOTE = 9.6 AMPS WIRED DIRECT OR PER LOCAL CODE 220 - 240/50/1 ALSO AVAILABLE, SEE MANUFACTURER. PLUMBING SPECIFICATIONS 3/8" (0.95cm) F.P.T. INLET, 1/2" (1.27cm) F.P.T. DRAIN 3/4" (1.91 cm) BIN DRAIN 3/8" (0.95cm) F.P.T. WATER CONDENSER INLET (WATER - COOLED UNIT) 1/2" (1.27cm) F.P.T. WATER CONDENSER OUTLET (WATER - COOLED UNIT) NSF APPROVED /U.L. #SA- 4027 /CSA LISTED MANITOWOC ICE CUBER \ REVIEWED FOR CODE COMPLIANCE APPROVED MAR 12 2009 City of Tukwila BUILDING DIVISION CITY FEB 02 2009 PERMIT CENTER *100, 200, 300 AND 400 ARE STANDARD SUBWAY MODEL SIZES. ENGINEERING SPECIFICATIONS: ACID RESISTANT COATED INTERIOR AND EXTERIOR FABRICATED STEEL. INTERNAL AIR RELIEF BYPASS. BRONZE CLEANOUT PLUG. REMOVABLE PRESSURE EQUALIZING /FLOW DIFFUSING INLET BAFFLE. FIXED BOTTOM OUTLET BAFFLE. VISIBLE DOUBLE WALL TRAP SEAL. NOTE: THESE DRAWINGS REPRESENT TYPICAL EQUIPMENT PURCHASED THROUGH DOCTOR'S ASSOCIATES INC. AND DOES NOT REPRESENT ANY EQUIPMENT PURCHASED LOCALLY BY THE FRANCHISEE/OWNER. OWNERS OF STORES OUTSIDE THE UNITED STATES AND CANADA MAY NEED ALTERNATE ELECTRICAL REQUIREMENTS. CONTACT YOUR DAI COORDINATOR OR THE MANUFACTURER FOR THE MODIFIED ELECTRICAL SPECIFICATIONS. STORE MUST BE CONSTRUCTED AS DESIGNED IN THESE FLOOR PLANS SUBJECT TO FEDERAL, STATE AND LOCAL LAWS. RECIPIENT IS RESPONSIBLE FOR ENSURING COMPLIANCE WITH ALL LAWS. IF MODIFICATIONS ARE NECESSARY, PLEASE CONTACT DAI'S STORE DESIGN DEPARTMENT FOR WRITTEN APPROVAL OF THE REQUIRED CHANGES. THIS DRAWING IS FURNISHED BY DOCTORS ASSOCIATES INC. ( "DAI ") D /B /A SUBWAY. RECIPIENT MUST DETERMINE IF THIS DRAWING MUST BE SUBMITTED TO A LICENSED ARCHITECT OR SIMILAR PROFESSIONAL UNDER FEDERAL, STATE OR LOCAL LAW. ANY CHANGES MUST BE APPROVED BY DAI. DO NOT SCALE DRAWING. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. AND SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR AND /OR FRANCHISEE/OWNER. ANY DISCREPANCY IN DIMENSIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF DAI'S AREA DEVELOPMENT AGENT OR DESIGNATED FIELD REPRESENTATIVE. THE GENERAL CONTRACTOR AND EACH SUB - CONTRACTOR SHALL MAKE HIS OWN INSPECTIONS AND MEASUREMENTS, DAI AND SUBWAY SHALL NOT BE HELD RESPONSIBLE FOR THE ACCURACY OF DIMENSIONS AND FOR ERRORS AND OMISSIONS IN THE DRAWINGS IF WRITTEN CONFIRMATION HAD NOT BEEN RECEIVED BY DAPS STORE DESIGN DEPARTMENT. THIS DRAWING AND THE INFORMATIONAL CONTENT HEREOF IS THE CONFIDENTIAL PROPERTY OF SUBWAY AND DAI AND IS PROVIDED SOLELY FOR THE USE OF AUTHORIZED FRANCHISEES, THEIR AGENTS AND CONTRACTORS. RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DRAWING AND /OR ITS INFORMATIONAL CONTENT, IN WHOLE OR IN PART, OR ALLOW SUCH FOR SUBWAY. RECIPIENT FURTHER AGREES TO SURRENDER THIS DRAWING AND ANY PERMITTED COPIES HEREOF UPON DEMAND. REVISION: m w 0 SHEET #: 30f4 ©2008 DOCTORS ASSOCIATES, INC.