Loading...
HomeMy WebLinkAboutPermit D09-027 - DIGITAL FOREST - ANTENNA SUPPORTDIGITAL FOREST ANTENNA SUPPORT 12101 TUKWILA INTERNATIONAL BL EXPIRED 03 -16 -10 D09 -027 Parcel No.: 0923049031 Permit Number: D09 -027 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Issue Date: 04/16/2009 Suite No: Permit Expires On: 10/13/2009 Tenant: Name: DIGITAL FOREST - ANTENNA SUPPORT Address: 12101 TUKWILA INTERNATIONAL BL , TUKWILA WA Owner: Name: INTERNATIONAL GATEWAY WEST Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA 98168 Phone: Contact Person: Name: STEVE HARGROVE Address: 7717 DETROIT AV SW , SEATTLE WA 98106 Phone: 206 768 -4000 Contractor: Name: MACDONALD MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE WA 98106 Phone: 206 763 -9400 Contractor License No: MACDOMF972BF Cityllf Tukwila • DESCRIPTION OF WORK: PROVIDE AND INSTALL (2) SATELLITE DISH STEEL SUPPORTS ON THE ROOF. INCLUDES ROOFING AROUND SUPPORT POSTS. Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us $90,650.00 DEVELOPMENT PERMIT * *continued on next page ** Expiration Date: 01/06/2011 Fees Collected: $2,171.94 International Building Code Edition: 2006 Occupancy per IBC: D09 -027 Printed: 04 -16 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The grantin of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructs n or the or ance of work authorized to sign and obtain this development permit. Signature: < ='�_�� Print Name: doc: IBC -10/06 City of•Tukwila 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulavila.wa.us L 14 t Private: Profit: N Private: Permit Number: D09 - 027 Issue Date: 04/16/2009 Permit Expires On: 10/13/2009 Public: Non - Profit: N Public: L -1(p1/4v' Date: ( - 1 / / ( o This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -027 Printed: 04 -16 -2009 Parcel No.: 0923049031 Address: Suite No: Tenant: r e City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12101 TUKWILA INTERNATIONAL BL TUKW DIGITAL FOREST - ANTENNA SUPPORT 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D09 -027 ISSUED 02/25/2009 04/16/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Installation of high- strength bolts shall be periodically inspected in accordance with AISC specifications. 5: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** D09 -027 Printed: 04 -16 -2009 • 0 City of Tukwila I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ( DA tz.L_A Date: 1 /) U / �� 1 D09 -027 Printed: 04 -16 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup://www.ci.tukwila. wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 17-- ■ O t � U kuo t o Tenant Name: ) i C� 14. , . s rl C 4,1 c\ Property Owners Name: o (,, Mailing Address: '12 t o -1- 1) k-1/4-0 t I +a % t lr D CONTACT PERSON - who do we contact when your permit is ready to be issued Name: _\ (.31) 4? Day Telephone: (2-(-- ) (o g -- ()op Mailing Address: '-] Z i — 1 +' t � S i,. �.> �S L■;) City State Zip E -Mail Address: S{- c. ..t . 3 r C-f n*ax Number: GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: MA c ' D r\ 0 ( I \ \ t r Mailing Address: Tip k L a) City Contact Person: Day Telephone: E -Mail Address: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: ? Mailing Address: G 1 2. 6a - State Zip Contact Person:_ Day Telephone: ( Z7 — 4 ,S9 9 S" E -Mail Address: Fax Number: Record ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Company Name: ANI A 5 Mailing Address: City State Zip Contact Person: �0 R 0 l.1 r C\. 0 C ) �') Day Telephone: (qa E -Mail Address: Fax Number: H:\Applications \Forms- Applications On Line \2009 Applications \I-2009 - Permit Application.doc Revised: 1 -2009 bh 4't+i, To City Fax Number: City 12 CH C Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. King Co Assessor's Tax Nn -: 09 230 3 C7 c ) Suite Number: . 5-J 9 e vt New Tenant: 1.� (For office use only) t70° U.) 1\ State State IA- Floor: tsco( Yes )4:. No Zip Zip 11 S 1 rl ,-e) Q S_ ZJ2 K i kI o . r ..a. wA a Y O33 Page 1 of 6 : : : � . • e : • • * , ` 'a'* . � 4 •; • 8 ? i .'. :F►'' , vr�: ; '..r t •: f. r. ; , ' 1 h • .: { + 'i. xistitig • ; ; t. F: r.• Y - :r r. ,..• . * x " : ;v +Intenor•:Rem del :.... Ad - -- Y' ^ • Eitistiii . g; .:'., ' - ; ' : t ..t:., e•7 ..: .; ; 't . [ '•;: r ': ! •New.' .. s: �• •- Type'of• . ,,.Constniction•per f : ...';IBC,:: •• :.. - .', ,Type o : • S . .Occupancy per - • • ' IBC • ' • '-Y .'. R ' .14' • •4 : i• • i :Tr; . ., h . 4.4 • ••• • '.2 °dF169.6 '.6 1: .. "' ' Ai: .:;.. .. -. : ; 3d Floor:' • x'E ' �' t r' ... *Floor§ • `'' ••9'•• ; �' • 13a:4 n:ent ' ",' • 'Accesso y Structure *• - • ;, Garage' • • • Detached Garage -'•" • ''" ' Attached Carport ' . • .1 etached'Carp'ort • ' , • ' Covered Deck..:' , . •Uricove'redDeck: ' Valuation of Project (contractor's bid price): $ q 0 I 6 -- Scope of Work (please provide detailed information): Pr r ✓ t r.1 n so...-1- 11 + e ? O r t' S n T v SC7 ( . i C t V (7 Q /"f) L� i /, q cs. rbV vc'► S p Ot*' g tiS }S • lJ Will there be new rack storage? ❑ Yes Existing Building Valuation: $ /k) 4 S s �� 1 oZ S 0. t 1� No If yes, a separate permit and plan submittal will be required. 4 Provide All Bulldiag Area's' in Sguar`e, Footage . Below;' = - PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1/2 " x 11 " paper including quantities and Material Sa ety Data Sheets. SEPTIC SYSTEM 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Wpplications\Forms- Applications On Line \2009 Applications \I -2009 - Permit Appheanon.doc Revised: 1.2009 bh Page 2 of 6 PERMIT:APPLIOATION NOTES - = _Applicable to. all.permits: in' this application. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN R OR AUTHORIZE Signature: Print Name: 'VA nay Telephone: e 0 .0 I - Mailing Address: - 7 - )1 - 1 1>e-k o > Prv—st. s LJ A 0 City State Zip Date Application Accepted: 0217-Gloal H:\Applications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1 -2009 bh Date Application Expires: Date: Staff Initials: Page 6 of 6 City of Tukwila 6200 Southcenter Blvd, Tukwila, WA SET RECEIP 1 Finance Department 0905601 -1 0 2/25/2009 BR1 T101 Wed Feb25,2009 05:05PM Trans #86 -87 86 $2682.44 DCDGEN - DCD Permits Plu - General Fund 87 $4.50 DCDOTH - DCD Permits Plus - Other Funds 2 ITEM(S): TOTAL: $2686.94 Check (002048) PAID $2686.94 www.ci.tukwila.wa.us 206 - 433 -1835 RECEIPT NO: R09 -00326 Initials: JR User ID: 1684 Payee: MACDONALD- MILLER FACILITY SOLUTIONS, INC. SET ID: 0225 SET NAME: DIGITAL FOREST - ANTENNA SET TRANSACTIONS: Set Member. Amount L09 -007 TOTAL: 2,171.94 515.00 2,171.94 TRANSACTION LIST: Type Method Description Payment Check 2048 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE ZONING /SUBDIVISION Citof Tukvvilar Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci.tukwila.wa.us TOTAL: Account Code Current Pmts 000/322.100 000/345.830 640.237.114 000/345.810 TOTAL: 1'7'_'_' .U1 - &JUOr. fi,{; UU1 111}, DCD Penni fPlu.s - Ge e - .a.l Fund 'r2 rl r ..x,6_', Amount 2,686.94 2,686.94 1,313.60 853.84 4.50 515.00 2,686.94 COMMENTS: Type of Inspectio /l 6 p 1 Q ` �Jv• IS- ,,, Address: 1 1Zt ( 7 /0 .,D 5/ ems. . ,.�� / c_i , 4 V ( ) A e A - r - 1.) 5 C./ 1.A �a.t►J, ( ' 0 q 7 p.m. Requester: j; I cif Phone No: - 7,n ( 0 1 ?r'(o - Ca I ?_ 6r, ( AL t =. Imo I � .�. � �/ ,)J W(f 5.)4, l - 2. lv 0.iki 3) `, ( r T (1 7 , 1 /ttt `/` i (... , (. d: ., ) I a . )- , , t . •.. /i { Project: _ • 1); rPS1 AA1 5�,�poi" Type of Inspectio /l 6 p 1 Q ` �Jv• IS- ,,, Address: 1 1Zt ( 7 Date Called: .,;��. �-� - .� Special Instructions: 11 'M &-, Al 5 Srtc\ 00> �t S4rGi\,te ' n,sk $`tee( S� f''' ?? ( I t m 0e/ MS T - , Date Wanted: 5 -- �a.t►J, ( ' 0 q 7 p.m. Requester: Phone No: - 7,n ( 0 1 ?r'(o - Ca I INSPECTION NO. INSPECTION RECORD Retain a copy with permit 9 - v 2 7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (t- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. brrections required prior to approval. Date: 7 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 1 REVIEWED FOR CODE COMPLIANCE APP t1VE APR 14 2009 City of Tukwila BUILDING DIVISION 12101 TUKWILA INTERNATi0NAi RI VD - TUKWILA, WA VAP TI VA No SCALE rir O E TUKVVAIA 1-17.13 2 5 2009 ERM T CENTER 1701 GIV- Plt# 41614 * COpp 1 .. , - Ito , 7�� Structural Calculations r � POGGEMEYER DESIGN GROUP For: Digital Forest Roof -top Antenna Frames (Building "C') 12101 Tukwila International Boulevard TUKWILA, WA 98168 POGGEMEYER DESIGN GROUP, INC. NW DIVISION 2 February 2009 PDGJOB No. 7094 -B CITY OF TUKWILA Calculations FEB 2 5 2009 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVE APR 14 2009 City of Tukwila BUILDING DIVISION Pages 1 -51 512 6th Street South, Suite 202 I Kirkland, Washington 98033 I P 425.827.59951 www.poggemeyer.com Shawn Hammer Digital.Forest 12101 Tukwila International Blvd. Tukwila, WA 98168 Subject: Executive Summary Building at 12101 Tukwila International Blvd. (Building "C") (2) Roof -top Steel Frames to Support (1) 3.5 -Meter Earth Station Antennas Each Mr. Hammer: As requested, the existing capacity of the building located at 12101 Tukwila International Blvd, as well as the design for two steel support frames, has been structurally evaluated for the loading imposed by the proposed Andrews Corp. 3.5 -M Antennas. The conclusions in this letter are limited to the specific areas of the roof as indicated in the attached layout drawings. Based on our study, it is structurally acceptable to locate the support frame with antennas as shown on the attached drawings and details. Also included with this letter is a calculation package to substantiate this conclusion. The attached calculations package validates the design and detailing of the support frame as shown per the Structural Drawings (separate) as produced by Poggemeyer Design Group. The structure has been designed for strength to the 2006 International Building Code design wind speed of 90 MPH. Because of the sensitivity of the antennas to movement, the frame has also been designed to a stiffness level to allow a maximum rotational deflection criteria of 0.0618 degrees at a minimum of 50 MPH, per the request of the client. The stiffness requirements where more critical than the strength requirements (controlling lateral load was 85 MPH 3 -sec. wind gust) as per code (IBC 06) and where the driving factor in selection of members and the detailing of the frame. Please feel free to contact me if you have any questions or comments. Sincerely, Ben Fisher I Project Engineer Poggemeyer Design Group, Inc. www.poggemeyer.com 512 Sixth Street South, Suite 202 Kirkland, WA 98033 2 February 2009 RE: Antenna Frame for (2) Andrew 3.5 -Meter Earth Station Antennas Digital Forest / Hughes Group Tukwila, WA PDG 7094 -A Building Department Set Submittal November 11 2008 STRUCTURAL ABSTRACT The project includes two steel frames that are designed to support (1) Andrew 3.5 -Meter Earth Station Antenna each, located on the roof of the Intergate West Building C. The design of the antenna itself is the responsibility of the manufacturer; the antenna is assumed to be sufficient based on the manufacturer's specifications. The manufacturer (Andrew Corporation) provides foundation loads as shown in attached "Foundation Specifications" publication, Bulletin 237731, Rev. A. These loads are imparted from the antenna base plate to the steel frame at the roof. The foundation loads provided by the manufacturer are given assuming a 150 MPH design wind speed. Because the given wind speed is too stringent for the Tukwila, Washington site, the design loads provided by the manufacturer have been reduced by a factor, as shown in the calculations, from 150 MPH (manufacturer design loads) to 85 MPH (code specified design wind speed). The frame is designed two address two major criteria: (1) the strength requirements and the (2) serviceability requirement. The first requirement is one of safety, which is based on the 85 MPH wind speed and other loads as specified per the code. The serviceability requirement, which is essentially the deflection criteria, as set by the client, have been determined to be a maximum rotation of 0.0168 degrees (0.00029 radians) at a minimum of 50 MPH, about any of the three orthogonal axes of rotation (e.g. X, Y and Z). The 2006 International Building Code (IBC) and 13 Edition ASCI Manuel of Steel Design are codes used in the following design. Wind loads were provided by the manufacturer of the antennas, so no calculations to derive wind loads via the wind speed and pressures were required. The seismic loads caused by the inertia of the antenna and the frame itself are only a fraction of the wind loading, so seismic design was not required. A snow loading of 25 PSF, per the IBC and City of Tukwila have been used at the metal deck. Because the steel frame is not a building structure, it is not required to be detailed as a special moment frame. The steel frame is designed with sufficient capacity to support the gravity and applied lateral loads of the antenna; snow loading on the metal deck surface; as well as its self weight and inertia forces. Due to the stringent deflection criteria and required stiffness of the members and connections to achieve the deflection limitations, the serviceability requirements govern over the strength requirements. In other words, due to the required rigidity of the frame, the strength provided by the members to resist gravity and lateral loads is many times greater than the is required. Ram AdvanSET"", a finite element modeling (FEM) program, was used to analyze both the frame as well as the existing supporting columns in the building below, as shown in attached key plans. The following report includes the outputs of the FEM analysis of both the frame and the supporting columns below. The coordinate system used by the Andrew Corporation Bulletin noted above is the same as used in the Ram AdvanSETM model. The loads have been scaled down in the model from 150 MPH level to either the 85 MPH (32.1% of 150 MPH) or 50 MPH (11.1% of 150 MPH) load condition. There are three load case families: (1) all 28 conditions as given in the attached manufacturer's literature, (2) the 28 conditions given in an orientation rotated 90° about the vertical axis and (3) the 28 conditions given in an orientation rotated only 45° about the vertical axis. fly POGGEMEYER DESIGN GROUP CONSULTING ENGINEERS POGGEMEYER DESIGN GROUP, INC. 512 6r St South. STE 202 Kirkland. WA 98033 (425) 627 -5995 (425) 828 -4650 Fox pdg-wo@pd9-wo.com NOM SIN • doazi c-) lic .c.331P •[.' • • •••• • ''''' . r . 4 • • 1 1 .Ii 177 ".77.761'. • • : i .e , . ...- . I l • l ■ . l l , I I I 0 I i i 1 I I I I . 0 I l II III. a NA , umului .... .., . . I I 11: .., I I I ll I I I I it IN igil I , l I MI WI 1 ■ 1 I . \ - lir t; ." WSVII ! ■ .......- ■..1. r: 4. ...v.,......— '.. V I ' 71, i ;7•■ . CP z's. 1 .1 .....rnat.w.4.1........I....n...... 41,....... 1 .1 II I fil 1110 I L., 14 i 1 ,10 ; • INAS- n417 r aim I. )1 i „ - ran 5710..e. .4ioaivimisp.;;-;itam • lb Alb /11/1■11/1•1/11/110/110/114111■■■■1111/110111111/1■4111111111/1,1111111A Kurt Zimmers From: Shawn Hammer [hammersd @forest.net] Sent: Friday, November 30, 2007 9 :11 AM To: Kurt Zimmers Cc: Kevin Teker Subject: antenna information Kurt- Just to summarize our earlier call: We received the following from our client: 1 1 J1 1 I looked at the AC-Building drawing AC -S2.6, issued 3/28/03, where we added a steel frame on the roof above the mechanical room to support four 3.5m and several smaller 1.8m antennas. We summarized the 3.5m antenna deflection criteria given us on the drawing as follows: "Maximum rotation of the antenna steel support frame at each antenna base: Rotation = 0.0168 degrees at 50 mph wind loading" This is the data we'd like to use for the rooftop support calcs. Please don't hesitate to contact Kevin or I if you have any further needs or questions to answer. Best, Shawn 11/30/2007 Installation Instructions Foundation Specifications for 3.5 -Meter Earth Station Antennas 1.0 INTRODUCTION 1.1 This document specifies typical foundation character- istics, designs, requirements and dimensional specifica- tions for the Andrew 3.5 -Meter Earth Station Antennas. 2.0 FOUNDATION LOADING CHARACTERISTICS 2.1 Foundation loads are applied to the foundation pad ANDREW® Andrew Corporation 10500 West 153rd Street Orland Park, IL U.S.A. 60462 Figure 1 Li Bulletin 237731 Revision A 1OREW as shown in Figure 1. Positive applied forces are in the direction of the X, Y, and Z coordinate axes. The XYZ coordinate system is centered at the bottom of the pedestal base plate and center of the pedestal tube. 2.2 Varying load conditions are dependent upon icing, inci- dent angle of the wind and elevation /azimuth angles of the antenna. Foundation loading forces and moments for vari- ous elevation versus wind conditions are listed in Table 1. Telephone: 708/349 -3300 Customer Service, 24 hours: U.S.A. • Canada • Mexico: 1- 800/255 -1479 FAX (U.S.A.): 1- 800/349 -5444 U.K.: 0800 250055 • Republic of Ireland: 1 800 535358 Printed In U.S.A. 11/02 Other Europe: +44 1592 782612 Copyright ® 2002 by Andrew Corporation 3.0 ANCHOR BOLT REQUIREMENTS 3.1 Typical anchor bolt installation configurations and dimensions are shown in Figure 2. 3.2 Andrew Type 302689 Anchor Bolt Kit includes anchor bolts, alignment plates and required mounting hardware as shown. 4.0 FOUNDATION DESIGNS 4.1 The selected foundation for a particular site is depen- dent upon local conditions. Soil borings and foundation analysis should be performed by a qualified civil engineer. 2 Table 1 4.2 A typical slab type foundation is shown in Figure 2. An enlarged copy of this design is available from Andrew on request. Refer to drawing number 240350. 5.0 FOUNDATION ORIENTATION 5 5.1 Proper foundation orientation is required to obtain the desired orbital arc coverage from a particular site location. The required azimuth and elevation angles of the antenna, relative to the mount must be determined to establish the appropriate foundation orientation. A specific foundation orientation requirement may be requested with the antenna as part of the installation package. • • • • • • • • • • • • • • • • • • • • • • . IP • • (J) iT CO C CD N CADWELIP TYPE OT WELDED ELEC. CONNECTION TIP. 4 PLCS. (WIRE TO GROUND ROD) LL SEE DETAIL 'B' #2 AWC SOLID TINNED COPPER GROUND WIRE TYPICAL CADWELD O TYPE PA WELDED ELEC CONNECTION TYP, 2 PLCS. (WIRE TO WARE) A CADWELUQ TYPE TA WELDED ELEC. CONNECTION (WIRE TO WIRE) TO EXTERNAL GROUND (*ERE APPLICABLE) L. 3" [76] CLR TYP. 1 [ [457 } NOMINAL POINTING DIRECTION 0 120 [305 226' 17.0 [432] 7— 16 • f6 O 91229] CT116 x 11'- 61M2D) L6. rz 2I 0] UIN T SFCTION "A —A" I ; -120 [305] 11 FL CONDUIT — 6' [1829] --- 12' 3655] TOP VIEW (TIP. BOP+ TOP a EwrICN -BGM IH EGTION51 I 1 ( 914 1 P • L 3' [78] CLR TW. (TOP & BOTTOM) 3/4' [19] 01A, x 6' - O' [2438] LG MIN. COPPERWELD GROUND ROD TYP, 4 PLR. POWER CONDUIT - OPTIONAL (SUGGESTED LOCATION) A 2 -0 ' 14113] MIN. trP, 6' [1829] 12' [3658] I A R 2' -0" [610]® IN. TIP. CADWELD ° TYPE HF WELDED ELEC CONNECTION TO ANTENNA STRUCTURE TYP. 2 PLCS. (WIRE TO STRUCTURE) 3' [76] APPROX ABOVE GRADE GRADE 2 [762] MIN. VOLUME OF CONCRETE 8.0 CUBIC YARDS (9,1 CUBIC METERS) WEIGHT OF REINFORCING B21 LDS (372 KILOGRAMS) 22.5' DFTAIL ANCHOR RD T PATTERN DFTAO NOT TO SCAT F 1' [ES] - 8 UNC, GALVANIZED ) THREADED ROD HEAV A-193 WITH HEAVY HEX NUTS GRADE WASHERS 8 PLACES) tL1it Ji (3/4' 114I0()� 924.0 8 X 1.0 -8UNC X 19,0 LONG ANCHOR BOLTS EO. SPACED ON 21.0 BOLT CIRCLE DIAMTER ANCHOR BOLT DETAIL (NOT TO SCALE ANDREW ANCHOR BOLT KIT, P/N 302689 ANTENNA PEDESTAL (SHOWN FOR REFERENCE ONLY) 3/4' [19] THK, STEEL ANCHOR PLATES `6� 1. Remove all burrs and sharp edges. 2. Dimensions apply before plating. 3. Interpret drawing per ANSI Y14.5M -1982. 4. Dimensions are shown in feet and inches. Dimensions in brackets [ ] are in millimeters. 5. A tolerance of ±1 /8" [3] applies to all anchor bolt layout dimensions. 6. Foundation Notes: A) This foundation is a typical design only. Certification of it's suitability for a particular installation by a professional engineer is required prior to it's use for actual fabrication. B) Contractor shall field verify all dimensions locating exist- ing construction before fabrication of new construction begins. C) Concrete and related work shall be mixed, placed and cured in accordance with "Building Code Requirements for Reinforced Concrete" ACI 318 -89 (Rev. 88) and "Specifications for Structural Concrete" ACI 301 -84 (Rev. 88) publication SP -15 (88). D) Concrete for foundations shall develop a compressive strength of at least 3000 psi [211 kgflcm in 28 days with a maximum slump of 3" [76] at time of placing. E) Reinforcing bars shall conform to ASTM A 615 [S1] grade 60 deformed type Fy = 60000 psi [4219 kgf /cm F) Unless otherwise noted, concrete cover of reinforcing bars shall conform to minimum requirements of ACI 318-89 (Rev. 88). G) Fabrication of reinforcing steel shall be in accordance with "Manual of Standard Practice for Detailing Reinforcing ConcreteStructures" ACI 315 -80 (Rev. 86). H) Provide 3/4" x 45° [19 x 451 chamfer on all exposed concrete edges. J) Foundations have been designed to rest on undis- turbed soil (per EIA -411 -A and RS- 222 -D) with a minimum allowable net vertical bearing capacity of 2000 psf [9770 kgf /m If undesirable soil conditions are encountered, the engineer shall be notified. K) Backfills shall be suitable excavated material or other suitable material compacted in 6" lifts to 90% of maximum density as determined by ASTM D1557. L) If this foundation is to be located in an area where annual frost penetration depth exceeds 15" [381], the local building code specifying a minimum required foundation depth should be consulted. 7. Grounding Electrode System Notes: The grounding system shown represents the minimum requirements to achieve satisfactory grounding. Actual site conditions and soil resistivity levels will determine final grounding system design to comply with the following: 4 General Notes A) All ground ring, ground rod and antenna structure connections to be EIRCO® products, Inc. Calweld® exothermic type welded electrical connections or equiva- lent. B) Ground rods shall be driven to a depth below perma- nent moisture level (minimum depth shown) as dictated by geographical location. C) The antenna structure shall be connected to a grounding electrode system consisting of a number of interconnected ground rods. The system shall meet the requirements of the Underwriters' Laboratories Publication No. ,UL96A for Lightning protection. D) The grounding electrode system to earth resistance shall not exceed 10 Ohms, measured with a Biddle 3 termi- nal device or equivalent. The grounded conductor (neutral) supplied to all ac equipment on the antenna structure should be disconnected before taking measurement. E) Actual site conditions may require longer ground rods, additional ground rods and /or land fill additives to reduce soil resistivity levels. F) Avoid sharp bends when routing grounding wire. Grounding wires to antenna structure to be run as short and straight as possible. G) Final grade directly above grounding electrode sys- tem to be water permeable. 8. Power /IFL Conduit Notes: A) Electrical power - Drawing depicts suggested location for electrical power conduit to antenna. Size, type and depth to bury conduit to be determined by customer in compliance with local codes. Direction to route conduit to be determined by the relative location of communcations building /shelter. Power conduit to extend 6" (minimum) above surface of foundation slab. Open ends of conduit to be sealed to prevent moisture and foreign particle contami- nation. Customer to provide main load center assembly and over- current protection devices for electrical equipment. Mounting location of load center to be determined by cus- tomer in accordance with local codes. B) For routing IFL cables, 4" size conduit recommended. Type and depth to bury conduit to be determined by cus- tomer, in compliance with local codes. Location of conduit on foundation and direction to route conduit to be deter- mined by location of communications building /shelter. Conduit to extend 36" (minimum) above surface of founda- tion slab. All bends to be large radius, maximum of two bends per run. Open ends of conduit to be sealed to pre- vent moisture and/or foreign particle contamination. 6.0 ANTENNA GEOMETRY 6.1 Figures 3 and 4 illustrate basic dimensional characteristics and azimuth adjustment range capabilities of the 3.5- meter antenna. Individual Component Weights Ground Mount = 998 lbs. Reflector = 652 lbs. 1 42" (1067 mm) 14" (356 mm) 62" (1575 mm) 12" (305 mm) 1- -4.5" (114 mm) R = 91.1" (2314 mm) R = 61.4" (1560 mm) Figure 3 Figure 4 5 POGGEMEYER DESIGN GROUP Consulting Engineers Made By: BSF Date: 11/11/08 Job No: 7094 Checked by: Sheet No: 512 6th Street South, Suite 202 Kirkland, WA 98033 (425) 827 -5995 Fax: (425) 828 -4850 Description: Job Name: Digital Forest Antenna Frame Foundation Loads for 150 MPH at Pedestal Mounting Point (from Manufacturer's Literature) Elevation 60- degrees Elevation 80- degrees Direct Load (Ibs) Moment Load (in -Ibs) Wind Angle Fx Fy Fz Mx My Mz Elevation 0- degrees O 0 -1,650 -8,732 - 640,329 13 866 30 -280 -1,650 -8,252 - 600,107 - 33,228 21,949 60 -560 -1,650 -7,771 - 559,850 - 66,476 43,037 90 909 -1,650 888 93,203 105,056 - 67,496 120 1,080 -1,650 2,554 219,338 124,130 - 80,370 150 541 -1,650 4,162 338,593 62,160 - 39,805 180 1 -1,650 5,769 457,813 167 775 Elevation 30- degrees O -33 -6,714 -7,005 - 445,580 -3,174 5,074 30 -305 -6,587 -6,868 - 440,658 - 29,717 39,538 60 -331 -5,690 -5,596 - 366,679 - 32,873 43,373 90 909 -1,900 767 71,674 86,178 - 112,882 120 1,013 -1,444 2,149 201,993 95,611 - 125,697 150 571 -987 3,314 304,952 53,821 - 70,406 180 18 -733 3,875 351,294 1,668 -1,379 O 0 -9,343 -3,400 - 166,421 -6 922 30 -192 -8,123 -3,008 - 168,461 - 10,371 31,961 60 178 -5,140 -1,723 - 120,880 8,887 - 26,677 90 909 - 1,565 441 36,425 47,153 - 142,760 120 887 -1,091 1,229 137,113 45,873 - 139,055 150 585 -771 1,916 229,590 30,226 - 91,370 180 0 -664 2,211 270,838 14 867 O -2 -4,161 -759 - 96,470 -33 1,233 30 245 -3,776 -691 - 91,630 3,962 - 39,443 60 577 -2,750 -420 - 63,370 9,411 - 94,580 90 909 -1,393 151 9,788 14,898 - 119,865 120 816 -1,200 657 91,284 13,356 - 134,324 150 486 -1,062 1,051 154,948 7,969 - 79,672 180 2 -1,013 1,202 179,369 41 592 POGGEMEYER DESIGN GROUP Consulting Engineers Made By: BSF Date: 11/11/08 Job No: 7094 Checked by: Sheet No: 512 6th Street South, Suite 202 Kirkland, WA 98033 (425) 827 -5995 Fax: (425) 828 -4850 Description: Wind Loads Job Name: Digital Forest Antenna Frame Parallel to Transverse Elevation 30- degrees Elevation 80- degrees Scaled Foundation Loads from 150 MPH down to 85 MPH Scale Factor: 0.32 Direct Load (kips) Wind Angle Fx Fy* Elevation 0- degrees Fz Moment Load (ft -kips) Mx My Mz Load Desc. O 0.0 -1.7 -2.8 -17.1 0.0 0.0 W1 0 -0 30 -0.1 -1.7 -2.6 -16.1 -0.9 0.6 W2 0 -30 60 -0.2 -1.7 -2.5 -15.0 -1.8 1.2 W3 0 -60 90 0.3 -1.7 0.3 2.5 2.8 -1.8 W4 0 -90 120 0.3 -1.7 0.8 5.9 3.3 -2.2 W5 0 -120 150 0.2 -1.7 1.3 9.1 1.7 -1.1 W6 0 -150 180 0.0 -1.7 1.9 12.3 0.0 0.0 W7 0 -180 O 0.0 -6.7 -2.2 -11.9 -0.1 0.1 W8 30 -0 30 -0.1 -6.6 -2.2 -11.8 -0.8 1.1 W9 30 -30 60 -0.1 -5.7 -1.8 -9.8 -0.9 1.2 W10 30 -60 90 0.3 -1.9 0.2 1.9 2.3 -3.0 W11 30 -90 120 0.3 -1.4 0.7 5.4 2.6 -3.4 W12 30 -120 150 0.2 -1.0 1.1 8.2 1.4 -1.9 W13 30 -150 180 0.0 -0.7 1.2 9.4 0.0 0.0 W14 30 -180 Elevation 60- degrees O 0.0 -9.3 -1.1 -4.5 0.0 0.0 W15 60 -0 30 -0.1 -8.1 -1.0 -4.5 -0.3 0.9 W16 60 -30 60 0.1 -5.1 -0.6 -3.2 0.2 -0.7 W17 60 -60 90 0.3 -1.6 0.1 1.0 1.3 -3.8 W18 60 -90 120 0.3 -1.1 0.4 3.7 1.2 -3.7 W19 60 -120 150 0.2 -0.8 0.6 6.1 0.8 -2.4 W20 60 -150 180 0.0 -0.7 0.7 7.2 0.0 0.0 W21 60 -180 O 0.0 -4.2 -0.2 -2.6 0.0 0.0 W22 80 -0 30 0.1 -3.8 -0.2 -2.5 0.1 -1.1 W23 80 -30 60 0.2 -2.8 -0.1 -1.7 0.3 -2.5 W24 80 -60 90 0.3 -1.4 0.0 0.3 0.4 -4.0 W25 80 -90 120 0.3 -1.2 0.2 2.4 0.4 -3.6 W26 80 -120 150 0.2 -1.1 0.3 4.1 0.2 -2.1 W27 80 -150 180 0.0 -1.0 0.4 4.8 0.0 0.0 W28 80 -180 * Direct Vertical Load (Fy) Not Scaled - Conservative POGGEMEYER DESIGN GROUP Consulting Engineers Made By: BSF Date: 11/11/08 Job No: 7094 Checked by: Sheet No: 512 6th Street South, Suite 202 Kirkland, WA 98033 (425) 827 -5995 Fax: (425) 828 -4850 Description: Wind Loads Job Name: Digital Forest Antenna Frame Parallel to Longit Scaled Foundation Loads from 150 MPH down to 85 MPH Direct Load (kips) Wind Angle Fx Fy* Elevation 0- degrees Fz Scale Factor: 0.32 Moment Load (ft -kips) Mx My Mz Load Desc. O -2.8 -1.7 0.0 0.0 0.0 -17.1 W29 0 -0 30 -2.6 -1.7 -0.1 0.6 -0.9 -16.1 W30 0 -30 60 -2.5 -1.7 -0.2 1.2 -1.8 -15.0 W31 0 -60 90 0.3 -1.7 0.3 -1.8 2.8 2.5 W32 0 -90 120 0.8 -1.7 0.3 -2.2 3.3 5.9 W33 0 -120 150 1.3 -1.7 0.2 -1.1 1.7 9.1 W34 0 -150 180 1.9 -1.7 0.0 0.0 0.0 12.3 W35 0 -180 Elevation 30- degrees O -2.2 -6.7 0.0 0.1 -0.1 -11.9 W36 30 -0 30 -2.2 -6.6 -0.1 1.1 -0.8 -11.8 W37 30 -30 60 -1.8 -5.7 -0.1 1.2 -0.9 -9.8 W38 30 -60 90 0.2 -1.9 0.3 -3.0 2.3 1.9 W39 30 -90 120 0.7 -1.4 0.3 -3.4 2.6 5.4 W40 30 -120 150 1.1 -1.0 0.2 -1.9 1.4 8.2 W41 30 -150 180 1.2 -0.7 0.0 0.0 0.0 9.4 W42 30 -180 Elevation 60- degrees O -1.1 -9.3 0.0 0.0 0.0 -4.5 W43 60 -0 30 -1.0 -8.1 -0.1 0.9 -0.3 -4.5 W44 60-30 60 -0.6 -5.1 0.1 -0.7 0.2 -3.2 W45 60-60 90 0.1 -1.6 0.3 -3.8 1.3 1.0 W46 60 -90 120 0.4 -1.1 0.3 -3.7 1.2 3.7 W47 60 -120 150 0.6 -0.8 0.2 -2.4 0.8 6.1 W48 60 -150 180 0.7 -0.7 0.0 0.0 0.0 7.2 W49 60 -180 Elevation 80- degrees O -0.2 -4.2 0.0 0.0 0.0 -2.6 W50 80 -0 30 -0.2 -3.8 0.1 -1.1 0.1 -2.5 W51 80 -30 60 -0.1 -2.8 0.2 -2.5 0.3 -1.7 W52 80-60 90 0.0 -1.4 0.3 -4.0 0.4 0.3 W53 80 -90 120 0.2 -1.2 0.3 -3.6 0.4 2.4 W54 80 -120 150 0.3 -1.1 0.2 -2.1 0.2 4.1 W55 80-150 180 0.4 -1.0 0.0 0.0 0.0 4.8 W56 80 -180 * Direct Vertical Load (Fy) Not Scaled - Conservative tt / / POGGEMEYER DESIGN GROUP Consulting Engineers Made By: BSF Date: 11/11/08 Job No: 7094 Checked by: Sheet No: 512 6th Street South, Suite 202 Kirkland, WA 98033 (425) 827 -5995 Fax: (425) 828 -4850 Description: Wind Loads Job Name: Digital Forest Antenna Frame Parallel to 0 = -45 deg. Scaled Foundation Loads from 150 MPH down to 85 MPH Direct Load (kips) Moment Load (ft -kips) Wind Angle Flt FBI* Fz Mx My Mz Elevation 0- degrees Scale Factor: 0.32 Rotation': -45 deg. Load Desc. O -2.0 -1.7 -2.0 -12.1 0.0 12.1 W57 0 -0 30 -1.9 -1.7 -1.8 -10.9 -0.9 11.8 W58 0 -30 60 -1.9 -1.7 -1.6 -9.8 -1.8 11.4 W59 0 -60 90 0.4 -1.7 0.0 0.5 2.8 -3.0 W60 0 -90 120 0.8 -1.7 0.3 2.6 3.3 -5.7 W61 0 -120 150 1.1 -1.7 0.8 5.7 1.7 -7.2 W62 0 -150 180 1.3 -1.7 1.3 8.7 0.0 -8.6 W63 0 -180 Elevation 30- degrees O -1.6 -6.7 -1.6 -8.3 -0.1 8.5 W64 30 -0 30 -1.6 -6.6 -1.5 -7.6 -0.8 9.1 W65 30 -30 60 -1.3 -5.7 -1.2 -6.1 -0.9 7.8 W66 30 -60 90 0.4 -1.9 0.0 -0.8 2.3 -3.5 W67 30-90 120 0.7 -1.4 0.3 1.4 2.6 -6.2 W68 30 -120 150 0.9 -1.0 0.6 4.4 1A -7.1 W69 30 -150 180 0.9 -0.7 0.9 6.6 0.0 -6.7 W70 30 -180 Elevation 60- degrees O -0.8 -9.3 -0.8 -3.1 0.0 3.2 W71 60 -0 30 -0.7 -8.1 -0.6 -2.6 -0.3 3.8 W72 60 -30 60 -0.4 -5.1 -0.4 -2.8 0.2 1.8 W73 60 -60 90 0.3 -1.6 -0.1 -2.0 1.3 -3.4 W74 60 -90 120 0.5 -1.1 0.1 0.0 1.2 -5.2 W75 60 -120 150 0.6 -0.8 0.3 2.6 0.8 -6.1 W76 60 -150 180 0.5 -0.7 0.5 5.1 0.0 -5.1 W77 60 -180 Elevation 80- degrees O -0.2 -4.2 -0.2 -1.8 0.0 1.8 W78 80-0 30 -0.1 -3.8 -0.2 -2.5 0.1 1.0 W79 80-30 60 0.0 -2.8 -0.2 -3.0 0.3 -0.6 W80 80 -60 90 0.2 -1.4 -0.2 -2.7 0.4 -3.0 W81 80 -90 120 0.3 -1.2 0.0 -0.8 0.4 -4.3 W82 80 -120 150 0.3 -1.1 0.1 1.4 0.2 -4.4 W83 80 -150 180 0.3 -1.0 0.3 3.4 0.0 -3.4 W84 80 -180 * Direct Vertical Load (Fy) Not Scaled - Conservative 1 Zero rotation results in a vector parallel to the transverse axis POGGEMEYER DESIGN GROUP Consulting Engineers Made By: BSF Date: 11/11/08 Job No: 7094 Checked by: Sheet No: 512 6th Street South, Suite 202 Kirkland, WA 98033 (425) 827 -5995 Fax: (425) 828 -4850 Description: Wind Loads Job Name: Digital Forest Antenna Frame Parallel to Transverse Scaled Foundation Loads from 150 MPH down to 50 MPH Scale Factor: 0.11 Wind Angle Fx FY Fz Mx My Mz Load Desc. Elevation 0- degrees Direct Load (kips) Moment Load (ft -kips) O 0.0 -1.7 -1.0 -5.9 0.0 0.0 W1 0 -0 30 0.0 -1.7 -0.9 -5.6 -0.3 0.2 W2 0 -30 60 -0.1 -1.7 -0.9 -5.2 -0.6 0.4 W3 0 -60 90 0.1 -1.7 0.1 0.9 1.0 -0.6 W4 0 -90 120 0.1 -1.7 0.3 2.0 1.1 -0.7 W5 0 -120 150 0.1 -1.7 0.5 3.1 0.6 -0.4 W6 0 -150 180 0.0 -1.7 0.6 4.2 0.0 0.0 W7 0 -180 Elevation 30- degrees O 0.0 -6.7 -0.8 -4.1 0.0 0.0 W8 30 -0 30 0.0 -6.6 -0.8 -4.1 -0.3 0.4 W9 30 -30 60 0.0 -5.7 -0.6 -3.4 -0.3 0.4 W10 30 -60 90 0.1 -1.9 0.1 0.7 0.8 -1.0 W11 30 -90 120 0.1 -1.4 0.2 1.9 0.9 -1.2 W12 30 -120 150 0.1 -1.0 0.4 2.8 0.5 -0.7 W13 30 -150 180 0.0 -0.7 0.4 3.3 0.0 0.0 W14 30 -180 Elevation 60- degrees O 0.0 -9.3 -0.4 -1.5 0.0 0.0 W15 60 -0 30 0.0 -8.1 -0.3 -1.6 -0.1 0.3 W16 60 -30 60 0.0 -5.1 -0.2 -1.1 0.1 -0.2 W17 60 -60 90 0.1 -1.6 0.0 0.3 0.4 -1.3 W18 60 -90 120 0.1 -1.1 0.1 1.3 0.4 -1.3 W19 60 -120 150 0.1 -0.8 0.2 2.1 0.3 -0.8 W20 60 -150 180 0.0 -0.7 0.2 2.5 0.0 0.0 W21 60 -180 Elevation 80- degrees O 0.0 -4.2 -0.1 -0.9 0.0 0.0 W22 80 -0 30 0.0 -3.8 -0.1 -0.8 0.0 -0.4 W23 80 -30 60 0.1 -2.8 0.0 -0.6 0.1 -0.9 W24 80 -60 90 0.1 -1.4 0.0 0.1 0.1 -1.4 W25 80 -90 120 0.1 -1.2 0.1 0.8 0.1 -1.2 W26 80 -120 150 0.1 -1.1 0.1 1.4 0.1 -0.7 W27 80 -150 180 0.0 -1.0 0.1 1.7 0.0 0.0 W28 80 -180 * Direct Vertical Load (Fy) Not Scaled - Conservative POGGEMEYER DESIGN GROUP Consulting Engineers Made By: BSF Date: 11/11/08 Job No: 7094 Checked by: Sheet No: 512 6th Street South, Suite 202 Kirkland, WA 98033 (425) 827 -5995 Fax: (425) 828 -4850 Description: Wind Loads Job Name: Digital Forest Antenna Frame Parallel to Longit Scaled Foundation Loads from 150 MPH down to 50 MPH Direct Load (kips) Wind Angle Fx Fy* Elevation 0- degrees Fz Scale Factor: 0.11 Moment Load (ft-kips) Mx My Mz Load Desc. O -1.0 -1.7 0.0 0.0 0.0 -5.9 W29 0 -0 30 -0.9 -1.7 0.0 0.2 -0.3 -5.6 W30 0 -30 60 -0.9 -1.7 -0.1 0.4 -0.6 -5.2 W31 0 -60 90 0.1 -1.7 0.1 -0.6 1.0 0.9 W32 0 -90 120 0.3 -1.7 0.1 -0.7 1.1 2.0 W33 0 -120 150 0.5 -1.7 0.1 -0.4 0.6 3.1 W34 0 -150 180 0.6 -1.7 0.0 0.0 0.0 4.2 W35 0 -180 Elevation 30- degrees O -0.8 -6.7 0.0 0.0 0.0 -4.1 W36 30 -0 30 -0.8 -6.6 0.0 0.4 -0.3 -4.1 W37 30 -30 60 -0.6 -5.7 0.0 0.4 -0.3 -3.4 W38 30 -60 90 0.1 -1.9 0.1 -1.0 0.8 0.7 W39 30 -90 120 0.2 -1.4 0.1 -1.2 0.9 1.9 W40 30 -120 150 0.4 -1.0 0.1 -0.7 0.5 2.8 W41 30 -150 180 0.4 -0.7 0.0 0.0 0.0 3.3 W42 30-180 Elevation 60- degrees O -0.4 -9.3 0.0 0.0 0.0 -1.5 W43 60 -0 30 -0.3 -8.1 0.0 0.3 -0.1 -1.6 W44 60 -30 60 -0.2 -5.1 0.0 -0.2 0.1 -1.1 W45 60 -60 90 0.0 -1.6 0.1 -1.3 0.4 0.3 W46 60 -90 120 0.1 -1.1 0.1 -1.3 0.4 1.3 W47 60 -120 150 0.2 -0.8 0.1 -0.8 0.3 2.1 W48 60 -150 180 0.2 -0.7 0.0 0.0 0.0 2.5 W49 60 -180 Elevation 80- degrees O -0.1 -4.2 0.0 0.0 0.0 -0.9 W50 80 -0 30 -0.1 -3.8 0.0 -0.4 0.0 -0.8 W51 80 -30 60 0.0 -2.8 0.1 -0.9 0.1 -0.6 W52 80 -60 90 0.0 -1.4 0.1 -1.4 0.1 0.1 W53 80 -90 120 0.1 -1.2 0.1 -1.2 0.1 0.8 W54 80 -120 150 0.1 -1.1 0.1 -0.7 0.1 1.4 W55 80 -150 180 0.1 -1.0 0.0 0.0 0.0 1.7 W56 80 -180 * Direct Vertical Load (Fy) Not Scaled - Conservative POGGEMEYER DESIGN GROUP Consulting Engineers Made By: BSF Date: 11/11/08 Job No: 7094 Checked by: Sheet No: 512 6th Street South, Suite 202 Kirkland, WA 98033 (425) 827 -5995 Fax: (425) 828 -4850 Description: Wind Loads Job Name: Digital Forest Antenna Frame Parallel to 6 = -45 deg. Scaled Foundation Loads from 150 MPH down to 50 MPH Direct Load (kips) Wind Angle Fx FY* Elevation 0- degrees Fz Moment Load (ft -kips) Mx My Mz Scale Factor: 0.11 Rotation -45 deg. Load Desc. O -0.7 -1.7 -0.7 -4.2 0.0 4.2 W57 0 -0 30 -0.7 -1.7 -0.6 -3.8 -0.3 4.1 W58 0 -30 60 -0.7 -1.7 -0.6 -3.4 -0.6 3.9 W59 0 -60 90 0.1 -1.7 0.0 0.2 1.0 -1.1 W60 0 -90 120 0.3 -1.7 0.1 0.9 1.1 -2.0 W61 0 -120 150 0.4 -1.7 0.3 2.0 0.6 -2.5 W62 0 -150 180 0.5 -1.7 0.5 3.0 0.0 -3.0 W63 0 -180 Elevation 30- degrees O -0.6 -6.7 -0.5 -2.9 0.0 3.0 W64 30 -0 30 -0.6 -6.6 -0.5 -2.6 -0.3 3.1 W65 30 -30 60 -0.5 -5.7 -0.4 -2.1 -0.3 2.7 W66 30-60 90 0.1 -1.9 0.0 -0.3 0.8 -1.2 W67 30 -90 120 0.2 -1.4 0.1 0.5 0.9 -2.1 W68 30 -120 150 0.3 -1.0 0.2 1.5 0.5 -2.5 W69 30 -150 180 0.3 -0.7 0.3 2.3 0.0 -2.3 W70 30 -180 Elevation 60- degrees O -0.3 -9.3 -0.3 -1.1 0.0 1.1 W71 60 -0 30 -0.3 -8.1 -0.2 -0.9 -0.1 1.3 W72 60 -30 60 -0.1 -5.1 -0.1 -1.0 0.1 0.6 W73 60 -60 90 0.1 -1.6 0.0 -0.7 0.4 -1.2 W74 60 -90 120 0.2 -1.1 0.0 0.0 0.4 -1.8 W75 60 -120 150 0.2 -0.8 0.1 0.9 0.3 -2.1 W76 60-150 180 0.2 -0.7 0.2 1.8 0.0 -1.8 W77 60 -180 Elevation 80- degrees O -0.1 -4.2 -0.1 -0.6 0.0 0.6 W78 80-0 30 0.0 -3.8 -0.1 -0.9 0.0 0.3 W79 80 -30 60 0.0 -2.8 -0.1 -1.0 0.1 -0.2 W80 80 -60 90 0.1 -1.4 -0.1 -0.9 0.1 -1.0 W81 80-90 120 0.1 -1.2 0.0 -0.3 0.1 -1.5 W82 80 -120 150 0.1 -1.1 0.0 0.5 0.1 -1.5 W83 80-150 180 0.1 -1.0 0.1 1.2 0.0 -1.2 W84 80 -180 * Direct Vertical Load (Fy) Not Scaled - Conservative 1 Zero rotation results in a vector parallel to the transverse axis u rrent Date: 2/2/2009 11:43 AM 110 its system: English File name: P: \Current Projects \7094 -1 Digital Forest UPS Installation \NEW Antenna Project \Design\Antenna Frame Model - 1- 19- 09.adv\ el 5 Bentley Current Date: 2/2/2009 11:43 AM Units system: English File name: P:\Current Projects17094 -1 Digital Forest UPS Installation\NEW Antenna Project\DesignlAntenna Frame Model - 1- 19- 09.adv1 / // / % / �l i / \ - - ,I i, r a \ / � �1 /r y. eoaf coNOt-Noe i LOB Current Date: 2/2/2009 11:49 AM fits system: English File name: P: \Current Projects \7094 -1 Digital Forest UPS Installation \NEW Antenna Project \Design\Antenna Frame Model - 1- 19- 09.adv\ a�i �� tl F( -'inee N1 (60004-1' OtPck -Pr►^ MS Bentley Current Date: 2/2/2009 11:32 AM Units system: English File name: P: \Current Pro ects\7094 -1 Di • ital Forest UPS Installation\NEW Antenna Pro ect \Desi• n\Antenna Frame Model - 1- 19- 09.adv\ N 20 wo065 (Ptili.“4.. PT (3 ) N 21 N 32 r rA Be n t L y 20 Current Date: 2/2/2009 11:31 AM Units system: English File name: P: \Current Projects \7094 -1 Digital Forest UPS Installation \NEW Antenna Project \Design\Antenna Frame Model - 1- 19- 09.adv\ Nodal displacements envelope Note.- lc is the controlling load condition Nodal displacements envelope for : ST =DL +SL LC1 =DL +SL +0.11 W 1 LC2 =DL +SL +0.11 W2 LC3 =DL +SL +0.11 W3 LC4 =DL +SL +0.11 W4 LC5 =DL +SL +0.11 W5 LC6 =DL +SL +0.11 W6 LC7 =DL +SL +0.11 W7 LC8 =DL +SL +0.11 W8 LC9 =DL +SL +0.11 W9 LC10 =DL +SL +0.11 W10 LC11 =DL +SL +0.11 W11 LC12 =DL +SL +0.11 W12 LC13 =DL +SL +0.11 W13 LC14 =DL +SL +0.11 W 14 LC15 =DL +SL +0.11 W15 LC16 =DL +SL +0.11 W16 LC17 =DL +SL +0.11 W17 LC 18 =DL +SL +0.11 W 18 LC 19 =DL +SL +0.11 W 19 LC20 =DL +SL +0.11 W20 LC21 =DL +SL +0.11 W21 LC22 =DL +SL +0.11 W22 LC23 =DL +SL +0.11 W23 LC24 =DL +SL +0.11 W24 LC25 =DL +SL +0.11 W25 LC26 =DL +SL +0.11 W26 LC27 =DL +SL +0.11 W27 LC28 =DL +SL +0.11 W28 LC29 =DL +SL +0.11 W29 LC30 =DL +SL +0.11 W30 LC31 =DL +S L +0.11 W31 LC32 =DL +SL +0.11 W32 LC33 =DL +SL +0.11 W33 LC34 =DL +SL +0.11 W34 LC35 =DL +SL +0.11 W35 LC36 =DL +SL +0.11 W36 LC37 =DL +SL +0.11 W37 LC38 =DL +S L +0.11 W 38 LC39 =DL +SL +0.11 W39 LC40 =DL +SL +0.11 W40 LC41 =DL +SL +0.11 W41 LC42 =DL +SL +0.11 W42 LC43 =DL +SL +0.11 W43 LC44 =DL +SL +0.11 W44 LC45 =DL +SL +0.11 W45 LC46 =DL +SL +0.11 W46 LC47 =DL +SL +0.11 W47 LC48 =DL +SL +0.11 W48 LC49 =DL +SL +0.11 W49 LC50 =DL +SL +0.11 W50 LC51 =DL +SL +0.11 W51 Analysis Results Pagel LC52 =DL +SL +0.11 W 52 LC53=DL+SL+0. 11W53 LC54 =DL +SL +0.11 W54 LC55 =DL +SL +0.11 W55 LC56 =DL +SL +0.11 W56 LC57 =DL +SL +0.11 W57 LC58 =DL +SL +0.11 W 58 LC59 =DL +SL +0.11 W59 LC60 =DL +SL +0.11 W60 LC61= DL +SL +0.11W61 LC62 =DL +SL +0.11 W62 LC63 =DL +SL +0.11 W63 LC64 =DL +SL +0.11 W64 LC65 =DL +SL +0.11 W65 LC66 =DL +SL +0.11 W66 LC67= DL +SL +0.11W67 LC68=DL+SL+0. 11W68 LC69=DL+SL+0. 11W69 LC70=DL+SL+0. 11W70 LC71 =DL +SL +0.11 W71 LC72 =DL +SL +0.11 W72 LC73 =DL +SL +0.11 W73 LC74 =DL +SL +0.11 W74 LC75 =DL +SL +0.11 W75 LC76 =DL +SL +0.11 W76 LC77 =DL +SL +0.11 W77 LC78 =DL +SL +0.11 W78 LC79 =DL +SL +0.11 W79 LC80 =DL +SL +0.11 W80 LC81 =DL +SL +0.11 W81 LC82 =DL +SL +0.11 W82 LC83 =DL +SL +0.11 W83 LC84 =DL +SL +0.11 W84 Translation Rotation Node X Ic Y Ic Z Ic Rx Ic Ry Ic Rz Ic [in] [in] [in] [Rad] [Rad] [Rad] 7 Max 0.006 LC35 -0.039 ST 0.007 LC7 0.00001 LC7 0.00003 LC33 0.00004 LC35 Min -0.012 LC29 -0.047 LC43 -0.010 LC1 - 0.00028 LC1 - 0.00001 LC31 - 0.00004 LC29 Page2 Il T'SON lS w (1,60 O ErdV6Iio 2.t Bentley urrent Date: 2/2/2009 11:32 AM Pits system: English 'He name: P: \Current Projects \7094 -1 Digital Forest UPS Installation \NEW Antenna Project \Design\Antenna Frame Model - 1- 19- 09.adv\ ry p ot5 17 (Fig -hme 5 Novi kft (in Dr) N 39 / / N25 48 N 15 N 37 /N4 41 N 30 N 43 Bentley _tF--05 Current Date: 2/2/2009 11:32 AM Units system: English File name: P: \Current Projects17094 -1 Digital Forest UPS Installation NEW Antenna Project \ Design \Antenna Frame Model - 1- 19- 09.adv\ Envelope for nodal reactions Note.- lc is the controlling load condition My Y c x F Y Mx F. } 1 Fz lvlz Direction of positive forces and moments Envelope of nodal reactions for ST =DL +SL LC1 =DL +SL +0.11 W 1 LC2 =DL +SL +0.11 W2 LC3 =DL +SL +0.11 W3 LC4 =DL +SL +0.11 W4 LC5 =DL +SL +0.11 W5 LC6 =DL +SL +0.11 W6 LC7 =DL +SL +0.11 W7 LC8 =DL +SL +0.11 W8 LC9 =DL +SL +0.11 W9 LC10 =DL +SL +0.11 W10 LC11= DL +SL +0.11W11 LC 12 =DL +SL +0.11 W 12 LC 13 =DL +SL +0.11 W 13 LC14 =DL +SL +0.11 W 14 LC15 =DL +SL +0.11 W 15 LC16 =DL +SL +0.11 W 16 LC17 =DL +SL +0.11 W17 LC18 =DL +SL +0.11 W18 LC 19 =DL +SL +0.11 W 19 LC20 =DL +SL +0.11 W20 LC21 =DL +SL +0.11 W21 LC22 =DL +SL +0.11 W22 LC23 =DL +SL +0.11 W23 LC24 =DL +SL +0.11 W24 LC25 =DL +SL +0.11 W25 LC26 =DL +SL +0.11 W26 LC27 =DL +SL +0.11 W27 LC28 =DL +SL +0.11 W28 LC29 =DL +SL +0.11 W29 LC30 =DL +SL +0.11 W30 LC31 =DL +SL +0.11 W31 LC32 =DL +SL +0.11 W32 LC33 =DL +SL +0.11 W33 LC34 =DL +SL +0.11 W34 LC35 =DL +SL +0.11 W35 LC36 =DL +SL +0.11 W36 LC37 =DL +SL +0.11 W37 LC38 =DL +SL +0.11 W38 LC39 =DL +SL +0.11 W39 LC40 =DL +SL +0.11 W40 Analysis Results Pagel LC41 =DL +SL +0.11 W41 LC42 =DL +SL +0.11 W42 LC43 =DL +SL +0.11 W43 LC44 =DL +SL +0.11 W44 LC45 =DL +SL +0.11 W45 LC46 =DL +SL +0.11 W46 LC47 =DL +SL +0.11 W47 LC48 =DL +SL +0.11 W48 LC49 =DL +SL +0.11 W49 LC50 =DL +SL +0.11 W50 LC51 =DL +SL +0.11 W51 LC52 =DL +SL +0.11 W52 LC53 =DL +SL +0.11 W53 LC54 =DL +SL +0.11 W54 LC55 =DL +SL +0.11 W55 LC56 =DL +SL +0.11 W56 LC57 =DL +SL +0.11 W57 LC58 =DL +SL +0.11 W58 LC59 =DL +SL +0.11 W59 LC60 =DL +SL +0.11 W60 LC61 =DL +SL +0.11 W61 LC62 =DL +SL +0.11 W62 LC63 =DL +SL +0.11 W63 LC64 =DL +SL +0.11 W64 LC65 =DL +SL +0.11 W65 LC66 =DL +SL +0.11 W66 LC67 =DL +SL +0.11 W67 LC68 =DL +SL +0.11 W68 LC69 =DL +SL +0.11 W69 LC70 =DL +SL +0.11 W70 LC71 =DL +SL +0.11 W71 LC72 =DL +SL +0.11 W72 LC73 =DL +SL +0.11 W73 LC74 =DL +SL +0.11 W74 LC75 =DL +SL +0.11 W75 LC76 =DL +SL +0.11 W76 LC77 =DL +SL +0.11 W77 LC78 =DL +SL +0.11 W78 LC79 =DL +SL +0.11 W79 LC80 =DL +SL +0.11 W80 LC81 =DL +SL +0.11 W81 LC82 =DL +SL +0.11 W82 LC83 =DL +SL +0.11 W83 LC84 =DL +SL +0.11 W84 Forces Moments Node Fx Ic Fy Ic Fz Ic Mx Ic My Ic Mz Ic [Kip] [Kip] [Kip] [Kip *ft] [Kip *ft] [Kip *ft] 18 Max 0.414 LC37 2.383 LC7 0.077 LC1 0.00000 ST 0.00000 ST 0.00000 ST Min 0.263 LC35 1.796 LC1 -0.066 LC7 0.00000 ST 0.00000 ST 0.00000 ST 19 Max 0.491 LC64 3.204 LC9 0.078 LC1 0.00000 ST 0.00000 ST 0.00000 ST Min 0.339 LC63 2.560 LC7 -0.065 LC7 0.00000 ST 0.00000 ST 0.00000 ST 20 Max -0.212 LC57 2.268 LC7 0.092 LC1 0.00000 ST 0.00000 ST 0.00000 ST Min -0.353 LC63 1.680 LC1 -0.051 LC7 0.00000 ST 0.00000 ST 0.00000 ST 21 Max -0.281 LC29 2.897 LC8 0.094 LC1 0.00000 ST 0.00000 ST 0.00000 ST Min -0.415 LC8 2.260 LC7 -0.049 LC7 0.00000 ST 0.00000 ST 0.00000 ST 32 Max -0.170 LC29 1.282 LC35 0.000 LC29 0.00000 ST 0.00000 ST 0.00000 ST Min -0.194 LC35 1.265 LC29 0.000 LC35 0.00000 ST 0.00000 ST 0.00000 ST Page2 33 Max 0.140 LC29 0.571 LC29 0.000 LC31 0.00000 ST 0.00000 ST 0.00000 ST Min 0.115 LC35 0.555 LC35 0.000 LC40 0.00000 ST 0.00000 ST 0.00000 ST Page3 urrent Date: 2/2/2009 11:36 AM its system: English 2-0 File name: P: \Current Projects \7094 -1 Digital Forest UPS Installation \NEW Antenna Project \Design\Antenna Frame Model - 1- 19- 09.adv\ • p 1 p 1 p • p --"-- w 1 gX 38�'__ C / m C 4\ 4X3 4,,,t,l x � C , / M / tn I b C 7X12. XILQ / F l o . - / / // a w c3/C>• ((ry a // a /ni la C 7XIj'2 �/ ` / Po /4 ti / / � .2 /, / ! m �1 � t i / C' j �I/ 1 ' o , /�' 7X12.2 0/ 4X�,� I X , 4 +I 8 , LW a J / // a /, LU 4X 38 X Mti � �M /x /� J N X W d Bentley Current Date: 2/2 /2009 11:35 AM Units system: English File name: P: \Current Projects \70941 Digital Forest UPS Installation \NEW Antenna Project \Design\Antenna Frame Model - 1- 19- 09.adv\ D Lri 0 0 Gl CO 3 a / o A9 `a- , 'R A36 / // PAraw M 4ltn.t q't.5 /1 I Q 2� z FtA Benttey Current Date: 2/2/2009 11:01 AM Units system: English File name: P: \Current Projects \7094 -1 Digital Forest UPS Installation\NEW Antenna Project \Design\Antenna Frame Model - 1- 19 -09.adv\ Report: Summary - Group by section Load conditions to be included in design : ST =DL +SL LC1= DL +SL +0.11W1 LC2= DL +SL +0.11W2 LC3= DL +SL +0.11W3 LC4= DL +SL +0.11W4 LC5= DL +SL +0.11W5 LC6= DL +SL +0.11W6 LC7= DL +SL +0.11W7 LC8= DL+SL +0.11W8 LC9= DL +SL +0.11W9 LC10= DL +SL +0.11W10 LC11= DL +SL +0.11W11 LC12= DL +SL +0.11W12 LC13= DL +SL +0.11W13 LC14= DL +SL +0.11W 14 LC15= DL+SL+0.11W15 LC16= DL +SL +0.11W16 LC17= DL +SL +0.11W17 LC18= DL +SL +0.11W18 LC19= DL +SL +0.11 W 19 LC20= DL +SL +0.11W20 LC21= DL +SL +0.11W21 LC22= DL +SL +0.11W22 LC23= DL +SL +0.11W23 LC24= DL +SL +0.11 W 24 LC25= DL +SL +0.11 W25 LC26= DL +SL +0.11W26 LC27= DL +SL +0.11W27 LC28= DL +SL+0.11W28 LC29= DL +SL +0.11W29 LC30 =DL +SL +0.11 W30 LC31= DL +SL +0.11W31 LC32= DL +SL +0.11W32 LC33= DL +SL +0.11 W33 LC34= DL +SL +0.11W34 LC35 =DL +SL +0.11 W35 LC36= DL +SL +0.11W36 LC37 =DL +SL +0.11 W37 LC38= DL +SL+0.11W38 LC39= DL +SL +0.11W39 LC40= DL +SL +0.11W40 LC41= DL +SL +0.11W41 LC42= DL +SL +0.11W42 LC43= DL +SL +0.11W43 LC44=DL+SL+0.11W44 LC45= DL +SL +0.11W45 LC46= DL +SL +0.11W46 LC47= DL +SL +0.11W47 LC48= DL +SL +0.11W48 LC49= DL +SL +0.11 W49 LC50= DL +SL +0.11W50 LC51= DL +SL +0.11W51 LC52= DL +SL +0.11W52 LC53= DL +SL +0.11W53 LC54= DL +SL +0.11W54 LC55= DL +SL +0.11W55 LC56= DL +SL +0.11W56 Steel Code Check Pagel 24 LC57 =DL +SL +0.11 W 57 LC58= DL+SL +0.11 W58 LC59= DL +SL +0.11W59 LC60= DL +SL +0.11 W60 LC61 = DL +SL +0.11 W61 LC62= DL +SL +0.11 W62 LC63= DL +SL +0.11 W63 LC64 =DL +SL +0.11 W 64 LC65 =DL +SL +0.11 W 65 LC66 =DL +SL +0.11 W66 LC67= DL +SL +0.11 W67 LC68= DL +SL +0.11 W68 LC69= DL+SL +0.11 W69 LC70= DL +SL +0.11 W70 LC71= DL+SL+0.11W71 LC72= DL +SL+0.11W72 LC73 =DL+SL +0.11 W73 LC74 = DL +SL +0.11 W74 LC75= DL +SL+0.11 W75 LC76 =DL+SL +0.11 W76 LC77= DL+SL +0.11 W77 LC78= DL+SL+0.11 W78 LC79 =DL +SL +0.11 W79 LC80 =DL +SL +0.11 W80 LC81= DL+SL +0.11W81 LC82= DL +SL +0.11W82 LC83= DL +SL+0.11 W83 LC84= DL +SL +0.11 W84 Description Section Member Ctrl Eq. Ratio Status Reference C 7X12.2 59 LC7 at 0.00% 0.47 OK (Ec. 4.9) DG 9 PIPE 2x0.154 46 LC8 at 100.00% 0.14 OK (H1 -1b) Column PIPE 4x0.337XS 11 LC64 at 50.00% 0.15 OK (H2 -1) Diagonal Brace C 7X12.2 24 LC1 at 100.00% 0.02 OK (H1 -1b) LU 4X3X1_4 20 LC36 at 0.00% 0.11 OK (H2 -1) Lateral Beam W 14X38 4 LC1 at 100.00% 0.03 OK (Ec. 4.9) DG 9 LESSER -POST PIPE 3x0.216 31 LO5 at 43.75% 0.16 OK (H3 -6) Long Beam W 10X19 30 LC29 at 75.78% 0.25 OK (H1 -1b) W 14X38 55 LC7 at 49.65% 0.11 OK (Ec. 4.9) DG 9 SMALL -DIAG LU 4X3X1_4 35 LOS at 0.00% 0.06 OK (H2 -1) TORQUE -TUBE HSS_RECT 14X6X3 8 8 LO7 at 0.00% 0.05 OK (H1 -1b) Paget 2.1 e_FreA ntte Current Date: 2/2/2009 11:19 AM Units system: English File name: P: \Current Projects \7094 -1 Digital Forest UPS Installation \NEW Antenna Project \Design\Antenna Frame Model - 1- 19- 09.adv\ Report: Summary - Group by member Load conditions to be included in design : ST =DL +SL LC1= DL +SL +0.11W1 LC2= DL +SL +0.11W2 LC3= DL +SL +0.11W3 LC4= DL +SL +0.11W4 LC5= DL +SL +0.11W5 LC6= DL +SL +0.11W6 LC7= DL +SL +0.11W7 LC8= DL +SL +0.11W8 LC9= DL +SL +0.11W9 LC10= DL +SL +0.11W10 LC11= DL +SL +0.11W11 LC12= DL +SL +0.11W12 LC13= DL +SL +0.11W13 LC14= DL +SL +0.11W14 LC15= DL +SL +0.11W15 LC16= DL +SL +0.11W16 LC17= DL +SL +0.11W17 LC18= DL +SL +0.11W18 LC19= DL +SL +0.11W19 LC20= DL +SL +0.11W20 LC21= DL +SL +0.11W21 LC22= DL +SL +0.11W22 LC23= DL +SL +0.11W23 LC24= DL +SL +0.11W24 LC25= DL +SL +0.11W25 LC26= DL +SL +0.11W26 LC27= DL +SL +0.11W27 LC28= DL +SL +0.11W28 LC29= DL +SL +0.11W29 LC30= DL +SL +0.11W30 LC31= DL +SL +0.11W31 LC32= DL +SL +0.11W32 LC33= DL +SL +0.11W33 LC34= DL +SL +0.11W34 LC35= DL +SL +0.11W35 LC36= DL +SL +0.11W36 LC37= DL +SL +0.11W37 LC38= DL +SL +0.11W38 LC39= DL +SL +0.11W39 LC40= DL +SL +0.11W40 LC41= DL +SL +0.11W41 LC42= DL +SL +0.11W42 LC43= DL +SL +0.11W43 LC44= DL +SL +0.11W44 LC45= DL +SL +0.11W45 LC46= DL +SL +0.11W46 LC47= DL +SL +0.11W47 LC48= DL +SL +0.11W48 LC49= DL +SL +0.11W49 LC50= DL +SL +0.11W50 LC51= DL +SL +0.11W51 LC52= DL +SL +0.11W52 LC53= DL +SL +0.11W53 LC54= DL +SL +0.11W54 LC55= DL +SL +0.11W55 LC56= DL +SL +0.11W56 Steel Code Check Pagel 3° LC57= DL +SL +0.11W57 LC58= DL +SL +0.11 W58 LC59= DL +SL +0.11W59 LC60= DL +SL +O.11W60 LC61= DL +SL+0.11W61 LC62= DL +SL +0.11W62 LC63= DL +SL +0.11W63 LC64= DL +SL +0.11 W64 LC65=DL+SL+0.11W65 LC66= DL +SL +0.11 W66 LC67= DL +SL +0.11 W67 LC68= DL +SL +0.11 W68 LC69= DL +SL +0.11 W69 LC70= DL +SL +0.11 W70 LC71= DL +SL +0.11W71 LC72= DL +SL +0.11W72 LC73= DL +SL +O.11W73 LC74= DL +SL+0. I 1 W74 LC75= DL +SL +0.11W75 LC76= DL +SL +0.11W76 LC77= DL +SL +0.11 W77 LC78= DL +SL +0.11 W78 LC79= DL+ SL+ 0.11W79 LC80= DL +SL +0.11 W80 LC81= DL +SL +0.11W81 LC82= DL +SL +0.11W82 LC83= DL +SL +0.11W83 LC84= DL +SL +0.11 W84 Description Column Diagonal Brace Section Member Ctrl Eq. Ratio Status Reference C 7X12.2 PIPE 2x0.154 44 LC15 at 100.00% 0.06 OK (H1 -1b) 45 LC35 at 100.00% 0.09 OK (H1 -1b) 46 LC8 at 100.00% 0.14 OK (H1 -1b) 56 LO5 at 100.00% 0.14 OK (H3 -6) PIPE 4x0.337XS 10 LC37 at 50.00 0.12 OK (H2 -1) 11 LC64 at 50.00% 0.1.5 OK (H2 -1) 12 LC63 at 50.00% 0.11 OK (H2 -1) 13 LC8 at 50.00% 0.14 OK (H1 -1b) C 7X12.2 22 LC1 at 50.00% 0.01 OK (H1 -1b) 23 LC1 at 50.00% 0.01 OK (H1 -1b) 24 LC1 at 100.00% 0.02 OK (H1-1b) 25 LC1 at 100.00% 0.02 OK (H1 -1b) 26 LC1 at 0.00% 0.02 OK (H1 -1b) 27 LC1 at 0.00% 0.02 OK (H1-1b) LU 4X3X1_4 47 LC9 at 62.50% 0.07 OK (Ec. 4.9) DG 9 48 LC8 at 74.22% 0.20 OK (EC. 4.9) DG 9 49 LC29 at 0.00% 0.04 OK (Ec. 4.9) DG 9 50 LC7 at 37.50% 0.33 OK (Ec. 4.9) DG 9 51 LC8 at 0.00% 0.02 OK (Ec. 4.9) DG 9 52 LC8 at 0.00% 0.01 OK (Ec. 4.9) DG 9 53 LC8 at 100.00% 0.01 OK (Ec. 4.9) DG 9 57 LC7 at 100.00% 0.05 OK (Ec. 4.9) DG 9 58 LC8 at 0.00% 0.42 OK (Ec. 4.9) DG 9 59 LC7 at 0.00% 0.47 OK (Ec. 4.9) DG 9 60 LC8 at 100.00% 0.08 OK (Ec. 4.9) DG 9 61 LQ9 at 0.00% 0.02 OK (H1 -1b) 62 LC29 at 0.00% 0.02 OK (H1 -Ib) 14 LC1 at 50.00% 0.03 OK (H2 -1) 15 LC1 at 0.00% 0.03 OK (H2 -1) 16 LC1 at 100.00% 0.02 OK (H2 -1) 17 LC1 at 50.00% 0.03 OK (H2 -1) 18 LC15 at 100.00% 0.09 OK (H2 -1) I 3' 4 1 1 4 1 I 1 1 1 I I I I I I I I I I I I I I I I I I I I Paget I Lateral Beam LESSER -POST Long Beam 19 LC35 at 0.00% 0.08 OK (H2 -1) 20 LC36 at 0.00% 0.11 OK (H2 -1) 21 LC37 at 100.00% 0.09 OK (H2 -1) W14X38 3 LC1 at 100.00% 0.03 OK (Ec. 4.9) DG 9 4 LC1 at 100.00% 0.03 OK (Ec. 4.9) DG 9 5 LC65 at 50.00% 0.02 OK (1-11 -1b) 6 LC5 at 50.00% 0.01 OK (H1 -lb) 7 LC15 at 100.00% 0.03 OK (Ec. 4.9) DG 9 PIPE 3x0.216 31 LC35 at 43.75% 0.16 OK (H3 -6) 32 LC29 at 43.75% 0.11 OK (113 -6) W 10X19 30 LC29 at 75.78% 0.25 OK (H1 -1b) W 14X38 1 LC43 at 49.22% 0.08 OK (Ec. 4.9) DG 9 55 LC7 at 49.65% 0.11 OK (Ec. 4.9) DG 9 SMALL -DIAG LU4X3X1_4 35 LC35at0.00% 0.06 OK (H2 -1) 36 LC29 at 100.00% 0.04 OK (H2 -1) TORQUE -TUBE HSS_RECT 14X6X3 8 8 LO7 at 0.00% 0.05 OK (H1 -1b) 9 LC65 at 100.00% 0.05 OK (H1 -1b) Page3 %Bent let Current Date: 2/2/2009 11:36 AM Units system: English File name: P: \Current Projects\7094 -1 Digital Forest UPS installation \NEW Antenna Project\Design\Antenna Frame Model - 1- 19 -09.adv1 Note.- Only the graphically selected members and shells are listed Members: List of materials Profile Material Uweight Length Weight [Kip /ft] [ft] [Kip] C 7X12.2 A36 1.23E -02 97.935 1.202 umilOMINIk. _ - 1 W itxl$ Aai I t kN 4.46E - 02 11.500 0.513 LU 4X3X1_4 A36 5.76E -03 53.071 0.306 PIPE 2X0.154 A500 GRB ROUNDED 3.62E -03 5.500 0.020 PIPE 3X0.216 A500 GRB ROUNDED 7.54E -03 12.000 0.090 PIPE 4X0.337XS A500 GRB ROUNDED 1.49E -02 24.000 0.358 W 10X19 A992 GR50 1.90E -02 19.500 0.371 W 14X38 A992 GR50 3.79E -02 69.000 2.613 Total weight [Kip] 5 473 Shells: Thickness Material Uweight Area Weight [in] [Kip/ft2] Ift2] [Kip] 0.04740 A653 SS GR33 1.94E -03 163.603 0.317 Total weight [Kip] 0.317 Pagel 33 qv Bonne kurrent Date: 2/2/2009 11:43 AM its system: English File name: P: \Current Projects \7094 -1 Digital Forest UPS Installation \NEW Antenna Project \Design\Antenna Frame Model - 1- 19- 09.adv\ A•rrtWpIPt PA4& (Alfas (rf-owl 1v1tI i if(1G[.) ex. 1,0A01ri Dih(ng4■A Ultvtit— ftAT6 014.04 67v>V0 vQQeo- f iA SNn•J • • Or t;Aol6't- Bentle Current Date: 2/2/2009 11:43 AM 35 Units system: English File name: P:\Current Pro'ects17094-1 Di ital Forest UPS Installation \NEW Antenna Pro'ect\Desi n\Antenna Frame Model - 1-19-09.adv\ eX. WtomeN't DrAAtitrA I ri Be stye current Date: 2/2/2009 11:49 AM Its system: English File name: P: \Current Projects \7094 -1 Digital Forest UPS Installation \NEW Antenna Project \Design\Antenna Frame Model - 1- 19- 09 -adv\ 6X• SNEan_ P.ArArLMK i4r53' Bentteg Current Date: 2/2/2009 11:44 AM Units system: English File name: P:\Current Pro'ects \7094 - Di• ital Forest UPS Installation \NEW Antenna Pro'ect \Desi•n\Antenna Frame Model - 1- 19- 09.adv\ EX. Axix l,o Olnkv-o-"n itley Current Date: 2/2/2009 3:00 PM Units system: English File name: P: \Current Projects \7094 -1 Digital Forest UPS Installation \NEW Antenna Project \Design\Antenna Frame Model - 1- 19- 09.adv\ GLOSSARY Cb22, Cb33 : Moment gradient coefficients Cm22, Cm33 : Coefficients applied to bending term in interaction formula d0 : Tapered member section depth at J end of member DJX : Rigid end offset distance measured from J node in axis X DJY : Rigid end offset distance measured from J node in axis Y DJZ : Rigid end offset distance measured from J node in axis Z DKX : Rigid end offset distance measured from K node in axis X DKY : Rigid end offset distance measured from K node in axis Y DKZ : Rigid end offset distance measured from K node in axis Z dL : Tapered member section depth at K end of member Ig factor : Inertia reduction factor (Effective Inertia/Gross Inertia) for reinforced concrete members K22 : Effective length factor about axis 2 K33 : Effective length factor about axis 3 L22 : Member length for calculation of axial capacity L33 : Member length for calculation of axial capacity LB pos : Lateral unbraced length of the compression flange in the positive side of local axis 2 LB neg : Lateral unbraced length of the compression flange in the negative side of local axis 2 RX : Rotation about X RY : Rotation about Y RZ : Rotation about Z TO : 1 = Tension only member 0 = Normal member TX : Translation in X TY : Translation in Y TZ : Translation in Z Nodes Node Geometry data X Y Z Rigid Floor [ft) [ft] [ft] 18 0.00 -6.00 6.00 0 19 0.00 -6.00 0.00 0 20 19.50 -6.00 6.00 0 21 19.50 -6.00 0.00 0 32 19.50 -6.00 -3.00 0 33 0.00 -6.00 -3.00 0 1 0.00 0.00 0.00 0 2 0.00 0.00 6.00 0 3 4.00 0.00 0.00 0 4 4.00 0.00 3.00 0 5 4.00 0.00 6.00 0 6 9.75 0.00 0.00 0 7 9.75 0.00 3.00 0 8 9.75 0.00 6.00 0 9 15.50 0.00 0.00 0 10 15.50 0.00 3.00 0 11 15.50 0.00 6.00 0 12 19.50 0.00 0.00 0 13 19.50 0.00 6.00 0 14 0.00 -3.00 6.00 0 15 0.00 -3.00 0.00 0 16 19.50 -3.00 6.00 0 Pagel 17 19.50 -3.00 0.00 0 22 19.50 -0.50 6.00 0 23 19.50 -0.50 0.00 0 24 0.00 -0.50 6.00 0 25 0.00 -0.50 0.00 0 26 2.00 0.00 3.00 0 27 17.50 0.00 3.00 0 28 3.75 0.00 0.00 0 29 15.75 0.00 0.00 0 30 3.75 0.00 -3.00 0 31 19.50 0.00 -3.00 0 34 11.75 0.00 -3.00 0 35 11.75 0.00 0.00 0 36 7.75 0.00 0.00 0 37 7.75 0.00 -3.00 0 38 17.00 0.00 -3.00 0 39 19.50 -2.50 -3.00 0 40 2.50 0.00 -3.00 0 41 0.00 -2.50 -3.00 0 42 15.75 0.00 -3.00 0 43 0.00 0.00 -3.00 0 46 4.00 1.375 3.00 0 47 15.50 1.375 0.901 0 48 3.237 1.375 -0.927 0 49 14.737 1.375 -3.00 0 50 15.50 0.00 0.901 0 51 14.737 0.00 -3.00 0 53 3.4171 0.00 0.00 0 54 3.4171 1.375 0.00 0 55 6.112 1.375 - 1.4453 0 56 8.987 1.375 - 1.9635 0 57 11.862 1.375 - 2.4818 0 58 12.625 1.375 1.4257 0 59 9.75 1.375 1.9505 0 60 6.875 1.375 2.4753 0 Restraints Node Members TX TY TZ RX RY RZ 18 1 1 1 0 0 0 19 1 1 1 0 0 0 20 1 1 1 0 0 0 21 1 1 1 0 0 0 32 1 1 1 0 0 0 33 1 1 1 0 0 0 Paget I 1 1 1 1 I Member NJ NK Description Section Material d0 dL Ig factor (f [in] [in] 1 2 13 Long Beam W 14X38 A992 Gr50 0.00 0.00 0.00 3 12 13 Lateral Beam W 14X38 A992 Gr50 0.00 0.00 0.00 4 1 2 Lateral Beam W 14X38 A992 Gr50 0.00 0.00 0.00 5 5 3 Lateral Beam W 14X38 A992 Gr50 0.00 0.00 0.00 6 8 6 Lateral Beam W 14X38 A992 Gr50 0.00 0.00 0.00 7 11 9 Lateral Beam W 14X38 A992 Gr50 0.00 0.00 0.00 8 7 10 TORQUE -TUBE HSS_RECT 14X6X3_8 A992 Gr50 0.00 0.00 0.00 9 4 7 TORQUE -TUBE HSS_RECT 14X6X3_8 A992 Gr50 0.00 0.00 0.00 10 2 18 Column PIPE 4x0.337XS A500 GrB rounded 0.00 0.00 0.00 11 1 19 Column PIPE 4x0.337XS A500 GrB rounded 0.00 0.00 0.00 12 13 20 Column PIPE 4x0.337XS A500 GrB rounded 0.00 0.00 0.00 13 12 21 Column PIPE 4x0.337XS A500 GrB rounded 0.00 0.00 0.00 14 23 16 Diagonal Brace LU 4X3X1_4 A36 0.00 0.00 0.00 15 17 22 Diagonal Brace LU 4X3X1_4 A36 0.00 0.00 0.00 16 24 15 Diagonal Brace LU 4X3X1_4 A36 0.00 0.00 0.00 17 14 25 Diagonal Brace LU 4X3X1_4 A36 0.00 0.00 0.00 18 9 17 Diagonal Brace LU 4X3X1_4 A36 0.00 0.00 0.00 19 16 11 Diagonal Brace LU 4X3X1_4 A36 0.00 0.00 0.00 20 15 3 Diagonal Brace LU 4X3X1_4 A36 0.00 0.00 0.00 21 5 14 Diagonal Brace LU 4X3X1_4 A36 0.00 0.00 0.00 22 13 9 Diagonal Brace C 7X12.2 A36 0.00 0.00 0.00 23 2 3 Diagonal Brace C 7X12.2 A36 0.00 0.00 0.00 24 1 26 Diagonal Brace C 7X12.2 A36 0.00 0.00 0.00 25 11 27 Diagonal Brace C 7X12.2 A36 0.00 0.00 0.00 26 26 5 Diagonal Brace C 7X12.2 A36 0.00 0.00 0.00 27 27 12 Diagonal Brace C 7X12.2 A36 0.00 0.00 0.00 30 43 31 Long Beam W 10X19 A992 Gr50 0.00 0.00 0.00 31 31 32 LESSER -POST PIPE 3x0.216 A500 GrB rounded 0.00 0.00 0.00 32 43 33 LESSER -POST PIPE 3x0.216 A500 GrB rounded 0.00 0.00 0.00 35 39 38 SMALL -DIAG LU 4X3X1_4 A36 0.00 0.00 0.00 36 40 41 SMALL -DIAG LU 4X3X1_4 A36 0.00 0.00 0.00 . 44 47 50 PIPE 2x0.154 A500 GrB rounded 0.00 0.00 0.00 45 46 4 PIPE 2x0.154 A500 GrB rounded 0.00 0.00 0.00 46 54 53 PIPE 2x0.154 A500 GrB rounded 0.00 0.00 0.00 47 48 46 C 7X12.2 A36 0.00 0.00 0.00 48 46 47 C 7X12.2 A36 0.00 0.00 0.00 49 47 49 C 7X12.2 A36 0.00 0.00 0.00 50 48 49 C 7X12.2 A36 0.00 0.00 0.00 51 58 57 C 7X12.2 A36 0.00 0.00 0.00 52 59 56 C 7X12.2 A36 0.00 0.00 0.00 53 60 55 C 7X12.2 A36 0.00 0.00 0.00 55 1 12 Long Beam W 14X38 A992 Gr50 0.00 0.00 0.00 56 49 51 PIPE 2x0.154 A500 GrB rounded 0.00 0.00 0.00 57 57 47 C 7X12.2 A36 0.00 0.00 0.00 58 58 56 C 7X12.2 A36 0.00 0.00 0.00 59 56 60 C 7X12.2 A36 0.00 0.00 0.00 60 55 46 C 7X12.2 A36 0.00 0.00 0.00 61 12 31 C 7X12.2 A36 0.00 0.00 0.00 62 1 43 C 7X12.2 A36 0.00 0.00 0.00 Hinges I I Page3 Member M33 M22 V3 V2 M33 M22 V3 V2 TOR AXL Axial rigidity 10 0 0 0 0 1 1 0 0 0 0 Full 11 0 0 0 0 1 1 0 0 0 0 Full 12 0 0 0 0 1 1 0 0 0 0 Full 13 0 0 0 0 1 1 0 0 0 0 Full 14 1 0 0 0 1 0 0 0 0 0 Full 15 1 0 0 0 1 0 0 0 0 0 Full 16 1 0 0 0 1 0 0 0 0 0 Full 17 1 0 0 0 1 0 0 0 0 0 Full 18 1 0 0 0 1 0 0 0 0 0 Full 19 1 0 0 0 1 0 0 0 0 0 Full 20 1 0 0 0 1 0 0 0 0 0 Full 21 1 0 0 0 1 0 0 0 0 0 Full 22 1 0 0 0 1 0 0 0 0 0 Full 23 1 0 0 0 1 0 0 0 0 0 Full 24 1 0 0 0 0 0 0 0 0 0 Full 25 1 0 0 0 0 0 0 0 0 0 Full 26 0 0 0 0 1 0 0 0 0 0 Full 27 0 0 0 0 1 0 0 0 0 0 Full 30 1 0 0 0 1 0 0 0 0 0 Full 31 1 1 0 0 1 1 0 0 0 0 Full 32 1 1 0 0 1 1 0 0 0 0 Full 35 1 0 0 0 1 0 0 0 0 0 Full 36 1 0 0 0 1 0 0 0 0 0 Full 44 1 1 0 0 0 0 0 0 0 0 Full 45 1 1 0 0 0 0 0 0 0 0 Full 46 1 1 0 0 0 0 0 0 0 0 Full 47 1 1 0 0 1 1 0 0 0 0 Full 48 1 1 0 0 1 1 0 0 0 0 Full 49 1 0 0 0 1 0 0 0 0 0 Full 50 1 1 0 0 1 1 0 0 0 0 Full 51 1 1 0 0 1 1 0 0 0 0 Full 52 1 1 0 0 1 1 0 0 0 0 Full 53 1 1 0 0 1 1 0 0 0 0 Full 56 1 1 0 0 0 0 0 0 0 0 Full 57 1 0 0 0 1 0 0 0 0 0 Full 58 1 0 0 0 1 0 0 0 0 0 Full 59 1 0 0 0 1 0 0 0 0 0 Full 60 1 0 0 0 1 0 0 0 0 0 Full 61 1 0 0 0 1 0 0 0 0 0 Full 62 1 0 0 0 1 0 0 0 0 0 Full Shells Shell 1 2 Node -J Node -K N1 N2 143 N4 Description Material Thickness [4 11 2 13 1 12 46 47 48 49 Page4 A653 SS Gr33 0.0474 A653 SS Gr33 0.0474 Load data p p Load conditions P P 1 P P 1 P • P 1 P GLOSSARY Current Date: 2/2/2009 3:02 PM Units system: English File name: P: \Current Projects \7094 -1 Digital Forest UPS Installation \NEW Antenna Project \Design\Antenna Frame Model - 1- 19- 09.adv\ Comb : Indicates if load condition is a load combination Condition Description DL Dead Load SL Snow Load W1 TO -0 W2 TO -30 W3 TO -60 W4 TO -90 W5 TO -120 W6 TO -150 W7 TO -180 W8 T30 -0 W9 T30 -30 W10 T30 -60 W11 T30 -90 W12 T30 -120 W13 T30 -150 W14 T30 -180 W15 T60 -0 W16 T60 -30 W17 T60 -60 W18 T60 -90 W19 T60 -120 W20 T60 -150 W21 T60 -180 W22 T80 -0 W23 T80 -30 W24 T80 -60 W25 T80 -90 W26 T80 -120 W27 T80 -150 W28 T80 -180 W29 L0 -0 W30 L0 -30 W31 L0 -60 W32 L0 -90 W33 L0 -120 W34 L0 -150 W35 L0 -180 W36 L30 -0 W37 L30 -30 W38 L30-60 W39 L30 -90 W40 L30 -120 W41 L30 -150 W42 L30 -180 W43 L60 -0 Pagel Comb. Category No DL No SNOW No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND No WIND W44 L60-30 No WIND W45 L60-60 No WIND W46 L60-90 No WIND W47 L60 -120 No WIND W48 L60 -150 No WIND W49 L60 -180 No WIND W50 L80 -0 No WIND W51 L80-30 No WIND W52 L80-60 No WIND W53 L80 -90 No WIND W54 L80 -120 No WIND W55 L80 -150 No WIND W56 L80 -180 No WIND W57 A0 -0 No WIND W58 A0 -30 No WIND W59 A0-60 No WIND W60 A0 -90 No WIND W61 A0 -120 No WIND W62 A0 -150 No WIND W63 A0 -180 No WIND W64 A30 -0 No WIND W65 A30 -30 No WIND W66 A30-60 No WIND W67 A30 -90 No WIND W68 A30 -120 No WIND W69 A30 -150 No WIND W70 A30 -180 No WIND W71 A60-0 No WIND W72 A60 -30 No WIND W73 A60-60 No WIND W74 A60-90 No WIND W75 A60 -120 No WIND W76 A60 -150 No WIND W77 A60 -180 No WIND W78 A80 -0 No WIND W79 A80 -30 No WIND W80 A80 -60 No WIND W81 A80 -90 No WIND W82 A80 -120 No WIND W83 A80 -150 No WIND W84 A0-180 No WIND ST DL +SL Yes LC1 DL +SL +0.11W1 Yes LC2 DL +SL +0.11W2 Yes LC3 DL +SL +0.11W3 Yes LC4 DL +SL +0.11W4 Yes LC5 DL +SL +0.11 W5 Yes LC6 DL +SL +0.11W6 Yes LC7 DL +SL +0.11W7 Yes LC8 DL +SL +0.11W8 Yes LC9 DL +SL +0.11W9 Yes LC10 DL +SL +O.11W10 Yes LC11 DL +SL +0.11W11 Yes LC12 DL +SL +0.11W12 Yes LC13 DL +SL +0.11W13 Yes LC14 DL +SL +0.11W14 Yes LC15 DL +SL +0.11W15 Yes LC16 DL +SL +0.11 W 16 Yes LC17 DL +SL +0.11W17 Yes LC18 DL +SL +0.11W18 Yes Paget 1 �}3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 a 1 1 1 1 1 a 1 1 1 1 1 1 1 1 I D D 1 lo o o 1 D o o LC19 DL +SL +0.11W19 LC20 DL +SL +0.11W20 LC21 DL +SL +0.11W21 LC22 DL +SL +0.11W22 1 LC23 DL +SL +0.11W23 LC24 DL +SL +0.11W24 LC25 DL +SL +0.11W25 LC26 DL +SL +0.11W26 LC27 DL +SL +0.11W27 LC28 DL +SL +0.11W28 LC29 DL +SL +0.11 W29 LC30 DL +SL +0.11 W30 LC31 DL +SL +0.11W31 LC32 DL +SL +0.11W32 LC33 DL +SL +0.11W33 LC34 DL +SL +0.11W34 LC35 DL +SL +0.11W35 LC36 DL +SL +0.11W36 LC37 DL +SL +0.11W37 LC38 DL +SL +0.11W38 LC39 DL +SL +0.11W39 LC40 DL +SL +0.11W40 ID LC41 DL +SL +0.11W41 LC42 DL +SL +0.11 W42 LC43 DL +SL +0.11 W43 LC44 DL +SL +0.11W44 LC45 DL +SL +0.11 W45 LC46 DL +SL +0.11W46 LC47 DL +SL +0.11W47 LC48 DL +SL +0.11W48 LC49 DL +SL +0.11 W49 P LC50 DL +SL +0.11W50 LC51 DL +SL +0.11W51 LC52 DL +SL +0.11W52 LC53 DL +SL +0.11W53 LC54 DL +SL +0.11W54 LC55 DL +SL +0.11W55 LC56 DL +SL +0.11W56 LC57 DL +SL +0.11W57 LC58 DL +SL +0.11W58 P LC59 DL +SL +0.11W59 LC60 DL +SL +0.11W60 LC61 DL +SL +0.11W61 LC62 DL +SL +0.11W62 LC63 DL +SL +0.11W63 LC64 DL +SL +0.11W64 LC65 DL +SL +0.11 W65 LC66 DL +SL +0.11W66 LC67 DL +SL +0.11W67 LC68 DL +SL +0.11W68 LC69 DL +SL +0.11W69 LC70 DL +SL +0.11 W70 LC71 DL +SL +0.11 W71 LC72 DL +SL +0.11 W72 LC73 DL +SL +0.11 W73 LC74 DL +SL +0.11W74 ID LC75 DL +SL +0.11W75 LC76 DL +SL +0.11W76 LC77 DL +SL +0.11W77 LC78 DL +SL +0.11W78 1 P P P P P P P 1 P Page3 P Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes LH LC79 DL +SL +0.11 W79 Yes LC80 DL +SL +0.11W80 Yes LC81 DL+SL+0.11W81 Yes LC82 DL +SL +0.11W82 Yes LC83 DL +SL +0.11W83 Yes LC84 DL +SL +0.11W84 Yes Load on nodes Condition Node FX FY FZ MX MY MZ [Kip] [Kip] [Kip] [Kip *ft] [Kip *ft] [Kip *ft] SL 49 0.00 -0.75 0.00 0.00 0.00 0.00 W1 7 0.00 -1.70 -3.10 -19.20 0.00 0.00 W2 7 -0.10 -1.70 -3.00 -18.00 -1.00 0.70 W3 7 -0.20 -1.70 -2.80 -16.80 -2.00 1.30 W4 7 0.30 -1.70 0.30 2.80 3.20 -2.00 W5 7 0.40 -1.70 0.90 6.60 3.70 -2.40 W6 7 0.20 -1.70 1.50 10.20 1.90 -1.20 W7 7 0.00 -1.70 2.10 13.70 0.00 0.00 W8 7 0.00 -6.70 -2.50 -13.40 -0.10 0.20 W9 7 -0.10 -6.60 -2.50 -13.20 -0.90 1.20 W10 7 -0.10 -5.70 -2.00 -11.00 -1.00 1.30 W11 7 0.30 -1.90 0.30 2.20 2.60 -3.40 W12 7 0.40 -1.40 0.80 6.10 2.90 -3.80 W13 7 0.20 -1.00 1.20 9.10 1.60 -2.10 W14 7 0.00 -0.70 1.40 10.50 0.10 0.00 W15 7 0.00 -9.30 -1.20 -5.00 0.00 0.00 W16 7 -0.10 -8.10 -1.10 -5.10 -0.30 1.00 W17 7 0.10 -5.10 -0.60 -3.60 0.30 -0.80 W18 7 0,30 -1.60 0.20 1.10 1.40 -4.30 W19 7 0.30 -1.10 0.40 4.10 1.40 -4.20 W20 7 0.20 -0.80 0.70 6.90 0.90 -2.70 W21 7 0.00 -0.70 0.80 8.10 0.00 0.00 W22 7 0.00 -4.20 -0.30 -2.90 0.00 0.00 W23 7 0.10 -3.80 -0.20 -2.70 0.10 -1.20 W24 7 0.20 -2.80 -0.20 -1.90 0.30 -2.80 W25 7 0.30 -1.40 0.10 0.30 0.40 -4.50 W26 7 0.30 -1.20 0.20 2.70 0.40 -4.00 W27 7 0.20 -1.10 0.40 4.60 0.20 -2.40 W28 7 0.00 -1.00 0.40 5.40 0.00 0.00 W29 7 -3 10 -1 70 0 00 0 00 0 00 -19.20 W30 7 -3.00 -1.70 -0.10 0.70 -1.00 -18.00 W31 7 -2.80 -1.70 -0.20 1.30 -2.00 -16.80 W32 7 0.30 -1.70 0.30 -2.00 3.20 2.80 W33 7 0.90 -1.70 0.40 -2.40 3.70 6.60 W34 7 1.50 -1.70 0.20 -1.20 1.90 10.20 W35 7 2.10 -1.70 0.00 0.00 0.00 13.70 W36 7 -2.50 -6.70 0.00 0.20 -0.10 -13.40 W37 7 -2.50 -6.60 -0.10 1.20 -0.90 -13.20 W38 7 -2.00 -5.70 -0.10 1.30 -1.00 -11.00 W39 7 0.30 -1.90 0.30 -3.40 2.60 2.20 W40 7 0.80 -1.40 0.40 -3.80 2.90 6.10 W41 7 1.20 -1.00 0.20 -2.10 1.60 9.10 W42 7 1.40 -0.70 0.00 0.00 0.10 10.50 W43 7 -1.20 -9.30 0.00 0.00 0.00 -5.00 W44 7 -1.10 -8.10 -0.10 1.00 -0.30 -5.10 1 i 1 i 1 1 1 1 1 1 1 1 1 1 1 1 i 1 1 1 1 1 1 1 Page4 I W45 7 -0.60 -5.10 0.10 -0.80 0.30 -3.60 W46 7 0.20 -1.60 0.30 -4.30 1.40 1.10 W47 7 0.40 -1.10 0.30 -4.20 1.40 4.10 ID W48 7 0.70 -0.80 0.20 -2.70 0.90 6.90 W49 7 0.80 -0.70 0.00 0.00 0.00 8.10 W50 7 -0.30 -4.20 0.00 0.00 0.00 -2.90 ' W51 7 -0.20 -3.80 0.10 -1.20 0.10 -2.70 W52 7 -0.20 -2.80 0.20 -2.80 0.30 -1.90 W53 7 0.10 -1.40 0.30 -4.50 0.40 0.30 W54 7 0.20 -1.20 0.30 -4.00 0.40 2.70 W55 7 0.40 -1.10 0.20 -2.40 0.20 4.60 W56 7 0.40 -1.00 0.00 0.00 0.00 5.40 W57 7 -2.20 -1.70 -2.20 -13.60 0.00 13.60 II W58 7 -2.20 -1.70 -2.00 -12.30 -1.00 13.20 W59 7 -2.10 -1.70 -1.80 -11.00 -2.00 12.80 W60 7 0.50 -1.70 0.00 0.50 3.20 -3.40 W61 7 0.90 -1.70 0.40 2.90 3.70 -6.40 W62 7 1.20 -1.70 0.90 6.30 1.90 -8.00 W63 7 1.50 -1.70 1.50 9.70 0.00 -9.70 W64 7 -1.80 -6.70 -1.80 -9.30 -0.10 9.60 W65 7 -1.80 -6.60 -1.70 -8.50 -0.90 10.20 W66 7 -1.50 -5.70 -1.30 -6.90 -1.00 8.70 ' W67 7 0.40 -1.90 0.00 -0.90 2.60 -3.90 W68 7 0.80 -1.40 0.30 1.60 2.90 -7.00 W69 7 1.00 -1.00 0.70 5.00 1.60 -8.00 W70 7 1.00 -0.70 1.00 7.40 0.10 -7.50 W71 7 -0.90 -9.30 -0.90 -3.50 0.00 3.50 W72 7 -0.80 -8.10 -0.70 -2.90 -0.30 4.30 W73 7 -0.40 -5.10 -0.50 -3.10 0.30 2.00 W74 7 0.30 -1.60 -0.10 -2.30 1.40 -3.80 W75 7 0.50 -1.10 0.10 0.00 1.40 -5.90 D W76 7 0.60 -0.80 0.30 2.90 0.90 -6.80 W77 7 0.60 -0.70 0.60 5.80 0.00 -5.70 W78 7 -0.20 -4.20 -0.20 -2.00 0.00 2.10 W79 7 -0.10 -3.80 -0.20 -2.80 0.10 1.10 W80 7 0.00 -2.80 -0.30 -3.40 0.30 -0.70 W81 7 0.30 -1.40 -0.20 -3.00 0.40 -3.40 W82 7 0.40 -1.20 0.00 -0.90 0.40 -4.80 W83 7 0.40 -1.10 0.10 1.60 0.20 -5.00 W84 7 0.30 -1.00 0.30 3.80 0.00 -3.80 1 I I I 1 • 1 1 • • I I I Load on shells Condition Shell Pressure Temp. [Kip /ft2] [F] DL 1 -0.003 0.00 2 -0.003 0.00 SL 1 -0.025 0.00 2 -0.025 0.00 Self weight multipliers for load conditions I • Page5 Self weight multiplier Condition Description Comb. MuItX MuitY MuItZ DL Dead Load No 0.00 -1.00 0.00 SL Snow Load No 0.00 0.00 0.00 W1 TO -0 No 0.00 0.00 0.00 W2 TO -30 No 0.00 0.00 0.00 W3 TO -60 No 0.00 0.00 0.00 W4 TO -90 No 0.00 0.00 0.00 W5 TO -120 No 0.00 0.00 0.00 W6 TO-150 No 0.00 0.00 0.00 W7 TO -180 No 0.00 0.00 0.00 W8 T30 -0 No 0.00 0.00 0.00 W9 T30 -30 No 0.00 0.00 0.00 W10 T30 -60 No 0.00 0.00 0.00 W11 130 -90 No 0.00 0.00 0.00 W12 130 -120 No 0.00 0.00 0.00 W13 T30 -150 No 0.00 0.00 0.00 W14 130 -180 No 0.00 0.00 0.00 W15 T60 -0 No 0.00 0.00 0.00 W15 T60 -30 No 0.00 0.00 0.00 W17 T60 -60 No 0.00 0.00 0.00 W18 T60 -90 No 0.00 0.00 0.00 W19 160 -120 No 0.00 0.00 0.00 W20 T60 -150 No 0.00 0.00 0.00 W21 T60 -180 No 0.00 0.00 0.00 W22 T80-0 No 0.00 0.00 0.00 W23 T80-30 No 0.00 0.00 0.00 W24 T80 -60 No 0.00 0.00 0.00 W25 180 -90 No 0.00 0.00 0.00 W26 T80 -120 No 0.00 0.00 0.00 W27 180 -150 No 0.00 0.00 0.00 W28 180 -180 No 0.00 0.00 0.00 W29 L0 -0 No 0.00 0.00 0.00 W30 L0 -30 No 0.00 0.00 0.00 W31 L0 -60 No 0.00 0.00 0.00 W32 L0 -90 No 0.00 0.00 0.00 W33 L0 -120 No 0.00 0.00 0.00 W34 L0-150 No 0.00 0.00 0.00 W35 L0 -180 No 0.00 0.00 0.00 W36 L30 -0 No 0.00 0.00 0.00 W37 L30-30 No 0.00 0.00 0.00 W38 L30 -60 No 0.00 0.00 0.00 W39 L30 -90 No 0.00 0.00 0.00 W40 L30 -120 No 0.00 0.00 0.00 W41 L30 -150 No 0.00 0.00 0.00 W42 L30 -180 No 0.00 0.00 0.00 W43 L60-0 No 0.00 0.00 0.00 W44 L60 -30 No 0.00 0.00 0.00 W45 L60-60 No 0.00 0.00 0.00 W46 L60 -90 No 0.00 0.00 0.00 W47 L60 -120 No 0.00 0.00 0.00 W48 L60 -150 No 0.00 0.00 0.00 W49 L60 -180 No 0.00 0.00 0.00 W50 L80 -0 No 0.00 0.00 0.00 W51 L80 -30 No 0.00 0.00 0.00 W52 L80 -60 No 0.00 0.00 0.00 W53 L80 -90 No 0.00 0.00 0.00 W54 L80 -120 No 0.00 0.00 0.00 W55 L80 -150 No 0.00 0.00 0.00 W56 L80 -180 No 0.00 0.00 0.00 W57 A0 -0 No 0.00 0.00 0.00 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 a 4 4 4 4 4 4 4 4 4 4 4 4 Page6 4 4 1 1 1 1 I 1 1 I • I W58 A0 -30 W59 A0 -60 W60 A0 -90 W61 A0-120 1 W62 A0 -150 W63 A0 -180 W64 A30 -0 W65 A30 -30 W66 A30 -60 W67 A30 -90 W68 A30 -120 W69 A30 -150 W70 A30 -180 W71 A60 -0 W72 A60 -30 W73 A60-60 W74 A60 -90 W75 A60 -120 W76 A60 -150 W77 A60 -180 W78 A80 -0 W79 A80 -30 W80 A80-60 W81 A80 -90 W82 A80 -120 W83 A80 -150 W84 A0 -180 ST DL +SL LC1 DL +SL +0.11W1 LC2 DL +SL +0.11W2 LC3 DL +SL +0.11W3 LC4 DL+SL+0.11W4 LC5 DL +SL +0.11W5 LC6 DL +SL +0.11W6 LC7 DL +SL +0.11W7 LC8 DL +SL +0.11W8 LC9 DL +SL +0.11W9 LC10 DL +SL +0.11W10 LC11 DL +SL +O.11W11 LC12 DL +SL +0.11W12 LC13 DL +SL +0.11W13 LC14 DL +SL +0.11W14 LC15 DL +SL +0.11W15 LC16 DL +SL +0.11W16 LC17 DL +SL +0.11W17 LC18 DL +SL +0.11W18 LC19 DL +SL +0.11W19 LC20 DL +SL +0.11W20 LC21 DL +SL +0.11 W21 LC22 DL +SL +0.11W22 LC23 DL +SL +0.11W23 LC24 DL +SL +0.11W24 LC25 DL +SL +0.11W25 LC26 DL +SL +0.11W26 LC27 DL +SL +0.11W27 LC28 DL +SL +0.11W28 • LC29 DL +SL +0.11W29 LC30 DL +SL +0.11W30 LC31 DL +SL +0.11W31 p p p Pagel No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 No 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 Yes 0.00 0.00 0.00 tfD LC32 DL +SL +0.11W32 Yes 0.00 0.00 0.00 LC33 DL +SL +0.11W33 Yes 0.00 0.00 0.00 LC34 DL+SL+0.11W34 Yes 0.00 0.00 0.00 LC35 DL +SL +0.11W35 Yes 0.00 0.00 0.00 LC36 DL +SL +0.11W36 Yes 0.00 0.00 0.00 LC37 DL +SL +0.11W37 Yes 0.00 0.00 0.00 LC38 DL+SL+0.11W38 Yes 0.00 0.00 0.00 LC39 DL +SL +0.11W39 Yes 0.00 0.00 0.00 LC40 DL +SL +0.11W40 Yes 0.00 0.00 0.00 LC41 DL +SL +0.11W41 Yes 0.00 0.00 0.00 LC42 DL +SL +0.11W42 Yes 0.00 0.00 0.00 LC43 DL +SL +0.11W43 Yes 0.00 0.00 0.00 LC44 DL +SL +0.11W44 Yes 0.00 0.00 0.00 LC45 DL+SL+0.11W45 Yes 0.00 0.00 0.00 LC46 DL +SL +0.11W46 Yes 0.00 0.00 0.00 L C47 DL +S L +0.11 W47 Yes 0.00 0.00 0.00 LC48 DL +SL +0.11W48 Yes 0.00 0.00 0.00 LC49 DL +SL +0.11W49 Yes 0.00 0.00 0.00 LC50 DL+SL+0.11W50 Yes 0.00 0.00 0.00 LC51 DL+SL+0.11W51 Yes 0.00 0.00 0.00 LC52 DL +SL +0.11W52 Yes 0.00 0.00 0.00 LC53 DL +SL +0.11W53 Yes 0.00 0.00 0.00 LC54 DL +SL +0.11W54 Yes 0.00 0.00 0.00 LC55 DL +SL +0.11W55 Yes 0.00 0.00 0.00 LC56 DL +SL +0.11W56 Yes 0.00 0.00 0.00 LC57 DL +SL +0.11W57 Yes 0.00 0.00 0.00 LC58 DL +SL +0.11W58 Yes 0.00 0.00 0.00 LC59 DL +SL +0.11W59 Yes 0.00 0.00 0.00 LC60 DL +SL +0.11W60 Yes 0.00 0.00 0.00 LC61 DL+SL+0.11W61 Yes 0.00 0.00 0.00 LC62 DL+SL+0.11W62 Yes 0.00 0.00 0.00 LC63 DL+SL+0.11W63 Yes 0.00 0.00 0.00 LC64 DL+SL+0.11W64 Yes 0.00 0.00 0.00 LC65 DL +SL +0.11W65 Yes 0.00 0.00 0.00 LC66 DL +SL +0.11W66 Yes 0.00 0.00 0.00 LC67 DL+SL+0.11W67 Yes 0.00 0.00 0.00 LC68 DL +SL +0.11W68 Yes 0.00 0.00 0.00 LC69 DL +SL +0.11W69 Yes 0.00 0.00 0.00 LC70 DL +SL +0.11 W70 Yes 0.00 0.00 0.00 LC71 DL+SL+0.11W71 Yes 0.00 0.00 0.00 LC72 DL +SL +0.11W72 Yes 0.00 0.00 0.00 LC73 DL+SL+0.11W73 Yes 0.00 0.00 0.00 LC74 DL +SL +0.11 W74 Yes 0.00 0.00 0.00 LC75 DL +SL +0.11 W75 Yes 0.00 0.00 0.00 LC76 DL +SL +0.11 W76 Yes 0.00 0.00 0.00 LC77 DL+SL+0.11W77 Yes 0.00 0.00 0.00 LC78 DL +SL +0.11W78 Yes 0.00 0.00 0.00 LC79 DL+SL+0.11W79 Yes 0.00 0.00 0.00 LC80 DL +SL +0.11W80 Yes 0.00 0.00 0.00 LC81 DL+SL+0.11W81 Yes 0.00 0.00 0.00 LC82 DL +SL +0.11 W82 Yes 0.00 0.00 0.00 LC83 DL +SL +0.11W83 Yes 0.00 0.00 0.00 LC84 DL +SL +0.11W84 Yes 0.00 0.00 0.00 Earthquake (Dynamic analysis only) Page8 Condition a/g Ang. Damp. [Deg] [ %l DL 0.00 0.00 0.00 SL 0.00 0.00 0.00 W1 0.00 0.00 0.00 W2 0.00 0.00 0.00 W3 0.00 0.00 0.00 ' W4 0.00 0.00 0.00 W5 0.00 0.00 0.00 W6 0.00 0.00 0.00 W7 0.00 0.00 0.00 W8 0.00 0.00 0.00 ID W9 0.00 0.00 0.00 W10 0.00 0.00 0.00 W 11 0.00 0.00 0.00 W12 0.00 0.00 0.00 • W13 0.00 0.00 0.00 W14 0.00 0.00 0.00 • W15 0.00 0.00 0.00 W16 0.00 0.00 0.00 W17 0.00 0.00 0.00 W18 0.00 0.00 0.00 W19 0.00 0.00 0.00 ID W20 0.00 0.00 0.00 W21 0.00 0.00 0.00 W22 0.00 0.00 0.00 W23 0.00 0.00 0.00 • W24 0.00 0.00 0.00 W25 0.00 0.00 0.00 W26 0.00 0.00 0.00 W27 0.00 0.00 0.00 W28 0.00 0.00 0.00 W29 0.00 0.00 0.00 W30 0.00 0.00 0.00 ' W31 0.00 0.00 0.00 W32 0.00 0.00 0.00 W33 0.00 0.00 0.00 W34 0.00 0.00 0.00 W35 0.00 0.00 0.00 • W36 0.00 0.00 0.00 W37 0.00 0.00 0.00 W38 0.00 0.00 0.00 W39 0.00 0.00 0.00 W40 0.00 0.00 0.00 W41 0.00 0.00 0.00 W42 0.00 0.00 0.00 W43 0.00 0.00 0.00 W44 0.00 0.00 0.00 W45 0.00 0.00 0.00 W46 0.00 0.00 0.00 W47 0.00 0.00 0.00 W48 0.00 0.00 0.00 W49 0.00 0.00 0.00 W50 0.00 0.00 0.00 W51 0.00 0.00 0.00 D W52 0.00 0.00 0.00 W53 0.00 0.00 0.00 W54 0.00 0.00 0.00 W55 0.00 0.00 0.00 W56 0.00 0.00 0.00 W57 0.00 0.00 0.00 D W58 0.00 0.00 0.00 Page9 I W59 0.00 0.00 0.00 W60 0.00 0.00 0.00 W61 0.00 0.00 0.00 W62 0.00 0.00 0.00 W63 0.00 0.00 0.00 W64 0.00 0.00 0.00 W65 0.00 0.00 0.00 W66 0.00 0.00 0.00 W67 0.00 0.00 0.00 W68 0,00 0.00 0.00 W69 0.00 0.00 0.00 W70 0.00 0.00 0.00 W71 0.00 0.00 0.00 W72 0.00 0.00 0.00 W73 0.00 0.00 0.00 W74 0.00 0.00 0.00 W75 0.00 0.00 0.00 W76 0.00 0.00 0.00 W77 0.00 0.00 0.00 W78 0.00 0.00 0.00 W79 0.00 0.00 0.00 W80 0.00 0.00 0.00 W81 0.00 0.00 0.00 W82 0.00 0.00 0.00 W83 0.00 0.00 0.00 W84 0.00 0.00 0.00 ST 0.00 0.00 0.00 LC1 0.00 0.00 0.00 LC2 0.00 0.00 0.00 LC3 0.00 0.00 0.00 LC4 0.00 0.00 0.00 LC5 0.00 0.00 0.00 LC6 0.00 0.00 0.00 LC7 0.00 0.00 0.00 LC8 0.00 0.00 0.00 LC9 0.00 0.00 0.00 LC 10 0.00 0.00 0.00 LC 11 0.00 0.00 0.00 LC12 0.00 0.00 0.00 LC13 0.00 0.00 0.00 LC14 0.00 0.00 0.00 LC15 0.00 0.00 0.00 LC 16 0.00 0.00 0.00 LC17 0.00 0.00 0.00 LC 18 0.00 0.00 0.00 LC19 0.00 0.00 0.00 LC20 0.00 0.00 0.00 LC21 0.00 0.00 0.00 LC22 0.00 0.00 0.00 LC23 0.00 0.00 0.00 LC24 0.00 0.00 0.00 LC25 0.00 0.00 0.00 LC26 0.00 0.00 0.00 LC27 0.00 0.00 0.00 LC28 0.00 0.00 0.00 LC29 0.00 0.00 0.00 LC30 0.00 0.00 0.00 LC31 0.00 0.00 0.00 LC32 0.00 0.00 0.00 LC33 0.00 0.00 0.00 Page10 I I LC34 0.00 0.00 0.00 II LC35 0.00 0.00 0.00 LC36 0.00 0.00 0.00 LC37 0.00 0.00 0.00 LC38 0.00 0.00 0.00 LC39 0.00 0.00 0.00 LC40 0.00 0.00 0.00 LC41 0.00 0.00 0.00 LC42 0.00 0.00 0.00 LC43 0.00 0.00 0.00 I LC44 0.00 0.00 0.00 LC45 0.00 0.00 0.00 LC46 0.00 0.00 0.00 ID LC47 0.00 0.00 0.00 LC48 0.00 0.00 0.00 I LC49 0.00 0.00 0.00 LC50 0.00 0.00 0.00 • LC51 0.00 0.00 0.00 LC52 0.00 0.00 0.00 • LC53 0.00 0.00 0.00 LC54 0.00 0.00 0.00 LC55 0.00 0.00 0.00 I LC56 0.00 0.00 0.00 LC57 0.00 0.00 0.00 • LC58 0.00 0.00 0.00 LC59 0.00 0.00 0.00 • LC60 0.00 0.00 0.00 LC61 0.00 0.00 0.00 ID LC62 0.00 0.00 0.00 LC63 0.00 0.00 0.00 LC64 0.00 0.00 0.00 I LC65 0.00 0.00 0.00 LC66 0.00 0.00 0.00 I LC67 0.00 0.00 0.00 LC68 0.00 0.00 0.00 I LC69 0.00 0.00 0.00 LC70 0.00 0.00 0.00 LC71 0.00 0.00 0.00 ID LC72 0.00 0.00 0.00 LC73 0.00 0.00 0.00 I LC74 0.00 0.00 0.00 LC75 0.00 0.00 0.00 I LC76 0.00 0.00 0.00 LC77 0.00 0.00 0.00 I LC78 0.00 0.00 0.00 LC79 0.00 0.00 0.00 LC80 0.00 0.00 0.00 I LC81 0.00 0.00 0.00 LC82 0.00 0.00 0.00 I LC83 0.00 0.00 0.00 LC84 0.00 0.00 0.00 • I I I I I • I I Pagell STEVE HARGROVE 7717 DETROIT AV SW SEATTLE WA 98106 i ty of Tukwila Department of Community Development RE: Permit No. D09 -027 12101 TUKWILA INTERNATIONAL BL TUKW Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/16/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. Sincerely, -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 03/16/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Bill Rambo Permit Technician %cX 26,t1 File: Permit File No. D09 -027 6300 Southcenter Boulevard. Suite #100 o Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 STEVE HARGROVE 7717 DETROIT AV SW SEATTLE WA 98106 City of Tukwila Department of Community Development Jack Pace, Director RE: Permit No. D09 -027 12101 TUKWILA INTERNATIONAL BL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/13/2009. Based on the above, you are hereby advised to: Jim Haggerton, Mayor 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 10/13/2009, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, . Bill Rambo Permit Technician File: Permit File No. D09 -027 A ?nn G..rRnent ,. P,.,1.,.,,.,4 G.:« u fnn _ r_1....:l_ rw,_ - n n,.,., _ ., ,_ IS March 5, 2009 Steve Hargrove 7717 Detroit Ave SW Seattle, WA 98106 ifer Marshall it Technician end File No. D09 -027 • city of Tukwila P:\Permit Center\Correction Letters\2009\D09 -027 Correction Letter #1.DOC jem 0 Department of Community Development Jack Pace, Director RE: CORRECTION LETTER #1 Development Permit Application Number D09 -027 Digital Forest (Antenna Support) —12101 Tukwila International BI Jim Haggerton, Mayor Dear Mr. Hargrove, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Planning Department. At this time the Building, Fire and Public Works Departments have no comments. Planning Department: Stacy MacGregor at 206 433 -7166 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. I have also enclosed a Non - Residential Sewer Use Certification that must be completed prior to issuance of the permit. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DATE: APPLICANT: RE: ADDRESS: PLANNING DIVISION COMMENTS March 4, 2009 Digital Forest — Antenna Support D09 -027 12101 Tukwila International Blvd The plans as submitted are not approved. Please review the following comments listed below and submit your revisions accordingly. If you have any questions on the requested revision, Stacy MacGregor is the planner assigned to the file and can be reached at 206 -433 -7166. 1. When this property was developed, it went through design review. Criteria for design review approval includes; "Mechanical equipment or other utility hardware on roof, ground or buildings should be screened from view." Plan approval will require screening of the satellites and supports. Show on plan. 2. If the "antenna supports /satellite dishes" meet the definition of wireless communication facilities as defined by Tukwila Municipal Code (below), then a permit for a wireless communication facility must be obtained and the requirements of the code must be met. See Tukwila Municipal Code Chapter 18.58 for more information. 18.06.936 Wireless Communication Facility "Wireless Communication Facility" means any tower, antenna, ancillary structure or facility, or related equipment or component thereof, which is used for the transmission of radio frequency signals through electromagnetic energy for the purpose of providing phone, internet, video, information services, specialized mobile radio, enhanced specialized mobile radio, paging, wireless digital data transmission, broadband, unlicensed spectrum services utilizing part 15 devices, and other similar services that currently exist or that may in the future be developed. (Ord. 2135 §2(part). 2006) ACTIVITY NUMBER: D09 -027 DATE: 04 -09 -09 PROJECT NAME: DIGITAL FOREST SITE ADDRESS: 12101 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Building Division Public Works Please Route REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 � PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP u n Fire Prevention Structural DETERMINATIO OF COMPLETENESS: (Tues., Thurs.) Complete V Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: APPROVALS 0 CORRECTIONS: Structural Review Required LETTER OF COMPLETENESS MAILED: n 0 'I Planning Division Permit Coordinator DUE DATE: 04-14-09 Not Applicable No further Review Required ri DATE: DUE DATE: 05 -12-09 Approved Approved with Conditions Not Approved (attach comments) Li Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D09 -027 DATE: 02 -25 -09 PROJECT NAME: DIGITAL FOREST - ANTENNA SUPPORT SITE ADDRESS: 12101 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMEN TS: building Di vision ` Pu lic As tl DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: 0 Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route KI Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 PERMIT CHORD COPY � PLAN REVIEW /ROUTING SLIP 40 t o. ;410-01 Fire Prevention Structural Incomplete n n Permit Coordinator n DATE: DATE: Planning Division TA DUE DATE: 02-26-09 Not Applicable No further Review Required DUE DATE: 03-26-09 Approved Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Obi S Departments issued corrections: Bldg ❑ Fire ❑ Ping PW ❑ Staff Initials: REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 4113 6 1 Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: DI 9 1 roof j,--, 1 Project Address: t al J I I l3 5.1cvc. H (&,DVC., n Summary of Revision: 15Q pod 11\ A ( 'friS C Y 11(, lI3. Contact Person: Entered in Permits Plus on flb City of Tukwila \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us d31NIO Al 6001 60 • Plan Check/Permit Number: 0 D — D �7 Phone Number: 2 76 T ] G 3 — (-Poo lake p � 9 ?009 Sheet Number(s): "Cloud" or highlight a 1 a eas of revision including date of revision Received at the City of Tukwila Permit Center by: ° [1961 License Name yp Type Specialty 1 p y Specialty 2 p y Effective Date Expiration Date Status ENCOMMS984JP ENCOMPASS MECHANICAL SERVICES ELECTRICAL CONTRACTOR MAINTENANCE HVAC /RFRG LTD ENERGY 4/17/2002 4/17/2004 EXPIRED ENCOMMS981JP ENCOMPASS MECHANICAL SERVICES ELECTRICAL CONTRACTOR HVAC /RFRG LTD ENERGY UNUSED 4/17/2002 4/17/2004 OUT OF BUSINESS MACDOMS982BM MACDONALD MILLER SERVICE INC ELECTRICAL CONTRACTOR MAINTENANCE UNUSED 1/14/2002 1/14/2004 OUT OF BUSINESS MACDOMS011 RS MACDONALD MILLER SERVICE INC ELECTRICAL CONTRACTOR HVAC /RFRG LTD ENERGY UNUSED 12/10/199912/10 /2003 OUT OF BUSINESS MACDOMC329B5 MACDONALD MILLER CO INC ELECTRICAL CONTRACTOR GENERAL UNUSED 1/25/1968 1/31/2003 OUT OF BUSINESS Untitled Page 0 Other Associated Licenses • Electrical Contractor A business licensed by Litt to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MACDONALD MILLER FAC SOL INC 2067639400 PO BOX 47983 SEATTLE WA 98106 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602254260 ACTIVE MACDOMF972BF ELECTRICAL CONTRACTOR 1/6/2003 1/6/2011 GENERAL UNUSED MASTER ELECTRICIAN INFORMATION License MCGIVMH979N8 Name MCGIVERN, MICHAEL H https://fortress.wa.gov/lni/bbip/Detail.aspx Page 1 of 2 04/16/2009 0 DESIGN CRITERIA CODE: INTERNATIONAL BUILDING CODE - 2006 EDITION ASCE 7 - 2005 EDITION ROOF 25 PSF SNOW BASIC WIND SPEED 90 MPH, EXPOSURE C ROTATIONAL CONSTRAINT AT DESIGN WIND SPEED 0.0169' (1.8 ARC MIN) DEFLECTION CRITERIA ASSUMED BY OWNER AND EXCEEDS CODE MINIMUM REQUIREMENTS SEISMIC MAPPED SPECTRAL ACCELERATION, Ss 1.501 MAPPED SPECTRAL ACCELERATION, Si 0.777 SOIL SITE CLASS D GENERAL CONDITIONS 1. THE CONTRACTOR SHALL EXAMINE THE STRUCTURAL DRAWINGS AND SHALL NOTIFY THE STRUCTURAL ENGINEER IN WRITING OF ANY DISCREPANCIES FOUND BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE STARTING WORK. 2. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER BEFORE PROCEEDING WITH ANY WORK SO INVOLVED. 3. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND 'TYPICAL DETAILS. WHERE THE NOTES, DRAWINGS, AND /OR SPECIFICATIONS DIFFER, THE MORE STRINGENT REQUIREMENT SHALL APPLY. 4. IF A SPECIFIC DETAIL IS NOT SHOWN FOR ANY PART OF THE WORK, THE CONSTRUCTION SHALL BE THE SAME AS FOR SIMILAR WORK. 5. WORKING DIMENSIONS SHALL NOT BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THESE DRAWINGS. 6. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE STRUCTURAL ENGINEER OF ANY CONDITION THAT, IN HIS OPINION, MIGHT ENDANGER THE STABIUTY OF THE STRUCTURE OR CAUSE DISTRESS TO THE STRUCTURE. 7. THE CONTRACTOR SHALL SUPERVISE AND DIRECT HIS WORK AND HE SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. 8. REFER TO THE ARCHITECTURAL DRAWINGS FOR INFORMATION NOT COVERED BY THESE GENERAL NOTES OR THE STRUCTURAL DRAWINGS. 9. ALL CONSTRUCTION SHALL BE DONE WITH MATERIALS, METHODS, AND WORKMANSHIP ACCEPTED AS GOOD PRACTICE BY THE CONSTRUCTION INDUSTRY AND IN CONFORMANCE WITH THE PROVISIONS OF THE IBC AND STANDARDS REFERENCED THEREIN. 10. PIPES, DUCTS, SLEEVES, OPENINGS, POCKETS, CHASES, BLOCK -OUTS, ETC., SHALL NOT BE PLACED IN SLABS, FOUNDATIONS, ETC., NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR SUCH ITEMS, UNLESS SPECIFICALLY DETAILED ON THESE STRUCTURAL DRAWINGS. 11. ALTERNATE ASSEMBUES AND MATERIALS WILL BE CONSIDERED FOR REVIEW. ENGINEER MAY REQUEST PAYMENT FOR REVIEW. DD STRUCTURAL AND MISCELLANEOUS STEEL FABRICATION AND ERECTION OF STEEL SHALL BE IN ACCORDANCE WITH THE FOLLOWING AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) STANDARDS AND SPECIFICATIONS: 1. MANUAL OF STEEL CONSTRUCTION, 13TH EDITION (ALLOWABLE STRESS DESIGN) 2. CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES, LATEST EDITION 3. SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. STEEL SHALL CONFORM TO THE FOLLOWING STANDARDS: WIDE FLANGE COLUMNS/BEAMS: ASTM 992 (Fy = 50 KSI) STEEL PIPE: SCHEDULE 80, CONFORMING TO ASTM A53, TYPE EXTRA - STRONG, GRADE B (Fy = 35 KSI) BOLTS: ASTM A325 OR A490 (STEEL /STEEL AND STEEL /CONC CONN) ALL ASTM A325 BOLTS SHALL BE SNUG -TIGHT U.N.O. ALL SLIP CRITICAL CONNECTIONS SHALL BE ASTM A325 BOLTS AND SHALL BE ENGINEER - APPROVED, SELF -LOAD INDICATING TYPES, AND SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ALL WELDING SHALL CONFORM TO THE AWS CODES, AND SHALL BE BY CERTIFIED WELDERS. WELDS NOT SPECIFIED SHALL BE 1/4" CONTINUOUS FILLET MINIMUM. USE DRY E70 ELECTRODES. ALL STEEL SHALL BE TREATED TO RESIST CORROSION, WHETHER BY GALVANIZATION OR BY ANTI- CORROSION PAINTS. STRUCTURAL STEEL WELDING 1. CONFORM TO THE AWS CODES D1.1 AND 01.3, AND USE ONLY CERTIFIED WELDERS. WELDS NOT SPECIFIED ARE TO BE 1/4" CONTINUOUS FILLET MINIMUM. INCREASE WELD SIZE TO AWS MINIMUM SIZES, BASED ON PLATE THICKNESS. USE DRY E70 ELECTRODES. 2. WHERE, SPECIFIED ON DRAWINGS, PROVIDE NON - DESTRUCTIVE TESTING OF WELDS. ALL SPECIFIED WELDS ARE TO BE TESTED 100% EITHER BY ULTRASONIC TESTING OR RADIOGRAPHY. JOBSITE SAFETY THE ENGINEER AND /OR ARCHITECT HAVE NOT BEEN RETAINED OR COMPENSATED TO PROVIDE DESIGN AND /OR CONSTRUCTION REVIEW SERVICES RELATED TO THE CONTRACTOR'S SAFETY PRECAUTIONS OR TO MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES FOR THE CONTRACTOR TO PERFORM HIS WORK. THE UNDERTAKING OF PERIODIC SITE VISITS BY THE ENGINEER SHALL NOT BE CONSTRUED AS SUPERVISION OF ACTUAL CONSTRUCTION NOR MAKE HIM RESPONSIBLE FOR PROVIDING A SAFE PLACE FOR THE PER - FORMANCE OF WORK BY THE CONTRACTOR, SUBCONTRACTORS, SUPPLIERS OR THEIR EMPLOYEES, OR FOR ACCESS, VISITS, USE, WORK, TRAVEL, OR OCCUPANCY BY ANY PERSON. SHOP DRAWINGS SUBMIT TWO SETS OF PRINTS AND ONE SET OF REPRODUCIBLES FOR REVIEW PRIOR TO FABRICATION FOR THE FOLLOWING: 1. STRUCTURAL STEEL 2. MISCELLANEOUS STEEL 3. METAL ROOF DECK SPECIAL INSPECTIONS 1. THE SPECIAL INSPECTOR FOR ALL WORK OUTLINED IN THE INTERNATIONAL BUILDING CODE SECTION 1704 SHALL BE A QUAUFIED PERSON WHO SHALL DEMONSTRATE HIS COMPETENCE TO THE SATISFACTION OF THE BUILDING OFFICIAL FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION, AND SHALL BE CHARGED MTh THE DUTIES AND RESPONSIBIUTIES AS OUTLINED IN IBC 1704. 2. THE OWNER, CONTRACTOR, SPECIAL INSPECTOR OR INSPECTION AGENCY AND PROJECT ENGINEER AND /OR ARCHITECT SHALL COMPLETE THE SPECIAL INSPECTION AND TESTING AGREEMENT TO THE SATISFACTION OF THE GOVERNING BUILDING DEPARTMENT. 3. THE SPECIAL INSPECTOR SHALL BE RESPONSIBLE FOR COMPLETING, MAINTAINING AND RESUBMITTING ALL SPECIAL INSPECTION LOGS AND FORMS AS REQUIRED BY THE BUILDING DEPARTMENT. ALL LOGS AND REPORTS ARE TO BE COMPLETED WITHIN ONE WEEK OF INSPECTIONS PERFORMED. (i) 1.'`••11` EXIST W24x55 - MAN DOOR "4�'i SCREEN a WALt; ; ALO NG- � 'PER SABEY'S REQUEST, -TO BE ADDkD AT-A_LOCATION AS DETERMINED BY1 SABEYa �ER,PLANS AND DETAILS FOR EXISTING SC WALLS EXIST W18x35 COLUMNS AT WORK PLATFORM SHALL CENTER OVER THE ROOF JOISTS AS SHOWN, REFER TO DETAILS S6, TYP. EXIST W1$x65 ; FULL ANTENNA SWING RADIUS - IS BLOCKED BY RAILING AND 04'- LADDERS, REFER TO SHEET S4 Fri W18x35 W24x55 COLUMNS AT WORK PLATFORM SHALL CENTER OVER THE ROOF JOISTS AS SHOWN, REFER TO DETAILS S6, TYP. FULL ANTENNA SWING RADIUS IS BLOCKED BY RAILING AND LADDERS, REFER TO SHEET S4 EXIST W18x35 PLATE TYPE A2 AT 16/53 PLATE TYPE Al AT 16/53 3 -0" PLANNING APPROVED • No changes can be made. to these plans without approval from ttto ,# Planning Division of COD �>a Approved A� App �' Data: It( Lv a% 3' -0" 3' -0" O ao PLATE TYPE A2 AT 16/53 31' -i INTERGATE WEST BUILDING C ROOF PLAN PARTIAL PLAN VIEW OF FRAME LOCATION ANTENNA FRAME LOCATION �uIuIuIuluuuIIIuIuuIIIuIululIIIIuIIIIIIuIIIuuuIuIuuIuuIiuii ®u` - ... 1 1 ' �iL' • P SEPARATE PER IT REQUIRED FOR: • Mechanical ti Electrical lumbing • Gas Piping -- y - - --- ---- SCALE: 1/16" = 1' -0" 5' -O" NI 1 MI - I • • + 1 Imi 6' -O" 3' -O" PLATE TYPE A2 AT 16/53 SCALE: 3/16" = 1' -0" REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. , F MAR .16 ZQ10 R EV 18 >FD POD CODE COMPLIANCE APR 14 2009 C BUILDING of ktuila LDING !VISION 1 City Of Tukwila BUILDING DIVISION FELE COPY Permit No. ttfl 'till Flan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and cond' ons is acknowledged: BY Date:, , SHEET INDEX ABBREVIATIONS: AB ANCHOR BOLT ALT ALTERNATE APPROX APPROXIMATE BIM BOTTOM BOT BOTTOM BRG BEARING BTW BETWEEN CUR CLEAR COL COLUMN CONC CONN CONST CONT CONTR CTR DET DIA DIAG DIM DL EA EF ELEV EQ EQUIP ES EW EXIST FF FG FLFR FIG RR FT FTG FS GA GALV GR HDG HT IF IN LOC LT MAX MECH MFR MIN MISC NO NS NTS OC OH OPNG OF PCF PSF PSI R REF REINF REQD S S1. GENERAL NOTES S2. FRAME PLAN AND SECTIONS S3. FRAME DETAILS S4. LADDER AND RAILING DETAILS S5. GLOBAL ELEVATIONS S6. WORK PLATFORM DETAILS CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CONTRACTOR CENTER DETAIL DIAMETER DIAGONAL DIMENSION DEAD LOAD EACH EACH FACE ELEVATION EQUAL EQUIPMENT EACH SIDE EACH WAY EXISTING FINISH FLOOR FINISH GRADE FLUSH FRAME FLANGE FLOOR FOOT FOOTING FAR SIDE GAUGE GALVANIZED GRADE HOT DIPPED GALVANIZED HORIZONTAL HEIGHT INSIDE FACE INCH JOINT UVE LOAD LOCATION UGHT MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS NUMBER NEAR SIDE NOT TO SCALE ON CENTER OPPOSITE HAND OPENING OUTSIDE FACE POUNDS PER CUBIC FOOT POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH RADIUS REFERENCE REINFORCING REQUIRED SLOPE SCHD SCHEDULE SEC SECTION SF SQUARE FOOT SFF STRUCTURAL FINISH FLOOR - SHT SHEET SIM SIMILAR SPCS SPACES SPEC SPECIFICATIONS STD STANDARD SR_ STEEL STRUCT STRUCTURAL T TOP THK THICK TOC TOP OF CONCRETE TOS TOP OF STEEL TOW TS TYP UNO VERT w WWF TOP OF WALL TUBE STEEL TYPICAL UNLESS NOTE OTHERWISE VERTICAL WITH WELDED HEADED STUD WEIGHT WELDED WIRE FABRIC MAR, U 6 MO RECEIVED CITY OF TUKWILA FEB 2 5 2009 PERMIT CENTER ► POGGEMEYER DESIGN GROUP 512 Sixth Street S, Suite 202 Kirkland, Washington 98033 p) 425.827.5995 f) 425.828.4850 www.poggemeyer.com O m 0 Q� a mw Win OW EgiA it- oc'o� tnOctV- a 0° 5,26ggi_ ge nun ggvh § - Nmce tn 1 EXPIRES OCTOBER 24, 20101 W 0 z Q tY LU z W w (1) Lil 0 U (f) U U V- O Q I I O Q � � O � U O f � r (f) Lf Q U z U L� � zQ CD 6 5ry, z cp CO JOB NUMBER 7094 -A DESIGNED BY BSF DRAWN BY BSF CHECKED BY RDB DATE 12 NOV 2008 SHEET NUMBER S1 OF S6 i NJ ivi - TO WF MIL/ 'Jim rli CONN. TYP. —, — - •- I I ma. ■ - - M! - -- .... -- - -- - - - - -- --- N I q U U U U O N -- I NJ ivi - TO WF MIL/ 'Jim rli CONN. TYP. —, — - •- , ' ma. ■ - - M! - -- .... -- - -- - - - - -- --- N I q U U U U O N -- c CJ U) LLB 3/4 "0 BOLT, TYP 3/4 "0 BOLT PLATE TYPE C2 DETAIL 17/S3 PER PLAN PER PLAN SHEET S1 SHEET S1 L4x3x1 CROSS BRACE K SHOWN BEYOND PLATE TYPE Cl DETAIL 17/S3 TO COLUMN STEEL PLATE DETAIL S2 • WATERPROOFING OR FLASHING NOT BY POGGEMEYER DESIGN GROUP, TYP EXISTING COLUMN BASE PLATE TYPE A2 ALL LOC ALONG GRID A PER DETAIL 17/S3 METAL r'E sz S2 r I • w•---- I- CONN FRAME DECK TO COL • I N wF TO WF (SOUTH ELEVATION SIMILAR) r - EXISTING WF GIRDER AT ROOF ANTENNA SUPPORT FRAME WEST ELEVATION CONN FRAME DEC COL CONN TO EXIST FRAMING EXISTING UNTOPPED METAL ROOF DECK (EAST ELEVATION SIMILAR) SCALE: 3/4 = -r r! [I i CHANNEL S`EC 'IONS WORK PLATFORM FRAME, PER SHEET S6, SHALL BE CONNECTED A53 GR B TO ANTENNA FRAME BY BOLT PIPE 4XS, TYP CONNECTION ONLY, REF. S6 • VULCRAFT 1.5 BI 18 RIBBED STEEL ROOF DECK (18 GA.) L ANTENNA BASE CONN., DETAIL �1 ANTENNA SUPPORT FRAME LENGTHWISE SECTION �J VULCRAFT 1.5 BI 18 RIBBED STEEL ROOF DECK (18 GA.) VULCRAFT 1.5 BI 18 RIBBED STEEL ROOF DECK (18 GA.) ANTENNA SUPPORT FRAME NORTH ELEVATION e •r ANTENNA BASE CONN DETAIL R 3/4 "x24 "x2' -0" TOP AND BIM AT ANTENNA BASE LOC. PER DETAIL 15/S3 SECTION A VULCRAFT 1.5 BI 18 RIBBED STEEL ROOF DECK (18 GA.) PLATE TYPE El PER DETAIL 17/ S . ...... ► ANTENNA SUPPORT FRAME TRANSVERSE SECTIONS UPPER (WORK) PLATFORM, SHOWN ROTATED 11' FROM ANTENNA FRAME .•..r.r... rw..- .,..mlwr,., 1 r`1 Lam` L „r SCALE: 3/4" = UPPER (WORK) PLATFORM, SHOWN ROTATED 11' FROM ANTENNA FRAME SCALE we = SECTION B r=1 0* TUBE PER D TAIL 7/S3 1 "0 ANTENNA=XNALBOLIS NOT BY - -•� DESIGN I PERPENDICULAR WF SHOWN BEYOND SHOWN BEYOND 11.1..r.1.] --------------------- = N11011 . - - -- ----- - - - - -- AIM PLATE TYPE C2 DETAIL 17/S3 PLATE TYPE C3 -'/ DETAIL 17/S3 STEEL PLATE DETAIL PERPENDICULAR WF SHOWN, BEYOND EXISTING ROOF DECK PLATE TYPE C3 DETAIL 17/53 L4x3x1/4 BRACING BASE PLATE TYPE Al ALONG GRID B BETWEEN GRIDS 5 -6 AND 7 -8, USE TYPE A2 ALL OTHER LOC., TYP PER DETAIL 17/S3 PLATE TYPE C2 DETAIL 17/S3 EXISTING WF ROOF MEMBER l SIDE PLATES WELDED TO TORQUE GEMEYER UP PLATE TYPE El PER 17/53 TOP AND BIM AT WF TO WF CONN, TYP. UPPER (WORK) PLATFORM FRAME, PER SHEET S6, RAILING PER SHEET S4 UPPER (WORK) PLATFORM FRAME, PER SHEET S6, RAILING PER SHEET S4 SUPPORT BEAM AND LATERAL BRACE BEAM AT EACH END, REFER TO 6/S5 SUPPORT BEAM AND LATERAL BRACE BEAM AT EACH END, REFER TO 6/S5 • 1 i TENNA BASE WF TO NIP PLAN DETAIL CROSS BRACE SHEAR TAB C A992 W14x38 A992 W14x38 A992 W14x3 P•' 'E El AT TOP, B1 AT BTM OF WF, ALL FOUR CORNER LOC. A992 W14x38 PLATE TYPE E1 AT TOP AND B TYP THIS CONDITI CROSS BRACE SHEAR TAB CON REFER TO SHEET S6 FOR WORK PLATFORM LOCATION AND DETAILS COLUMN SHOWN BEYOND A53 GR B PIPE 4XS, TYP SECTION A SECTION B a (p 0) WF TO WF PLAN DETAIL I 1 CONN FRAME DECK TO COL • 6' -0" ANTENNA SUPPORT FRAME PLAN VIEW 3/4" CHAMFER ALL EXPOSED STEEL WF CORNERS VULCRAFT 1.5 BI 18 RIBBED STEEL ROOF DECK (18 GA.), 5/8" PUDDLE WELDS, 7/36 FASTENER LAYOUT 3' -0" REFER TO SHEET S4 FOR LADDER AND RAILING PLAN AND DETAILS [ LATERAL BRACE BEAM SCALE: 3/4" = 1' -0" LATERAL BRACE BEAM bO9oi7 METAL DECK NOT REQUIRED AT THIS LOCATION UPPER (WORK) PLATFORM FRAME, PER SHEET S6, RAILING PER SHEET 24 • UPPER (WORK) PLATFORM SUPPORT BEAM FIEVIBWE® FOR CODE COMPLIANCE APR 14 2009 City of Tukwila DIVIS1ON MAR , 16 MO CITY OF T FEB 2 5 2009 PERMIT CENTER POGGEMEYER DESIGN GROUP 512 Sixth Street S, Suite 202 Kirkland, Washington 98033 p) 425.827.5995 1) 425.828.4.850 www.poggemeyer.com >- m 5 v) 0 0 W Cr W 0 N I EXPIRES OCTOBER 24, 20101 z 0 W (I) z a- —J I— W W LL > O Q O $1 O F a_ z w ( ( ) V) Q WO z� N Z 0 __I CD z Q f-- CD z 0 -i CO JOB NUMBER 7094 —A DESIGNED BY BSF DRAWN BY BSF CHECKED BY RDB DATE 12 NOV 2008 SHEET NUMBER S2 OF S6 i REFER TO PLATE TYPE El DETAIL 17/S3, CONN. PER 2/S3 PLATE El AT TOP (2) 3/4 "0 BOLTS REFER TO PLATE TYPE El DETAIL 17/S3, CONN. PER 2/S3 WF PER PLAN COL PER PLAN REFER TO PLATE TYPE D1 DETAIL 17/S3 AT SHEAR TAB WF TO WF CONN. DETAIL SCALE 1 1/2" = r -o WELD TO WF PER DETAIL 2/S3 /iMT ._ir-- -_i_ PLATE TYPE B1 PER 17/S3 SHEAR PLATE TYPE D1 PER 17/S3, WELD PER DETAIL 1/S3 1/4 3 ®12 C TORQUE TUBE DETAIL C nos me Li % / / / / //.1v mm woria m riririri - irirs� p si i• WF PER PLAN CORNER CONN. TO COL. I 1/4 "x12 7/8 "x5' -2 ", PLATE AT TORQUE TUBE LOC. BOTH SIDES SCALE 1 1/2" = 1' -0" (2) 3/4 "0 BOLTS BASE PLATE Al OR A2 PER 5/S2 AND 17/S3 (4) 3/4 "0 BOLTS TO EXISTING MEMBER PLATE TYPE El AT TOP PER DETAILS 17/S3 AND 2/S3 PLATE TYPE B1 PER 17/S3 SHOWN BEYOND SECTION D COL. CONN. TO EXISTING FRAMING SCALE 1 1/2" = 1' -0" WF PER PLAN SCALE 1 1/2" = FLASHING AND WATERPROOFING NOT BY POGGEMEYER EXIST UNTOPPED METAL ROOF DECK PLATE PER 5/82 AND 17/83 EXIST WF MEMBER IN ROOF WF TO WF CONN. DETAIL 1 1/2" 2 1/2" PLAN WEW SECTION A REFER TO PLATE TYPE El DETAIL 17/S3 WF PER PLAN WF PER PLAN 1/4 / PER PLAN SCALE 1 1/2" = 1 - 0 " 1/4 N UNDERSIDE PATE TO WF R 3/4 "x7 "x0' -10 1/2" COL PIPE BTM PLATE 7/8 "0 BOLT HOLE TRANSVERSE WF PER PLAN CROSS BRACE PER PLAN 3 1/2" 3 1/2" NOTE: USED ONLY AT GRID B BETWEEN GRIDS 5 -6 AND 7 -8 PLATE Al 1 1/4 "x2 "x0' -6 ", AT TOP AND BTM 3/16" 2 1/2" 2 1/2" 1/4" 7/8 "0 BOLT HOLE 7/8 "0 BOLT HOLE 3/16" 2 1/2" 2 1/2" 1 1/2" 2 " 1 1/2" 3" CROSS BRACE PER PLAN LONG WF PER PLAN IN -PLANE CROSS BRACE SCALE 1 i /� = i - o" 3 3/4" 1 1/2" 1 1/2" 1 1/2" 3 " 3" NOTE: USED ALL ALONG GRID A AND ALONG GRID B BETWEEN GRIDS 6 -7 2 1/2" PLATE C3 1 1/4 "x2 "x0' -6 ", AT TOP AND BTM STEEL PLATE DETAILS SECTION Z PLATE Fl 17/S3, SECTION Y SHEAR TAB, CENTERED IN -PLANE CROSS BRACE SCALE 1 1/2" = 1 - 0 " 1/2" CHAMFER AT EXPOSED CORNERS VIEW FROM ABOVE VIEW FROM PERPENDICUALR SIDE 3/8" CHAMFER, TYP. 1 1/2" 1 1/2" 2 " 1 1/2" I 1/4"x3 1/2 "x0' -5 3/8" SCALE 3/4" = 1' -0" VIEW FROM SIDE PLATE 91 " COPE BOTH ENDS 5 3/8" PLATE D1 LONG WF PER PLAN PLATE F2 17/S3, BACK SIDE OF CHANNEL, TYP., CENTERED (2) 1/2 "0 BOLTS EA., AT PLATES Fl AND F2 BEGIN WELD 1/2" FROM EDGE OF PLATE 1 3/8 "x5 1/2 "xO' -8 1/4", COL PIPE TOP PLATE REFER TO PLATE Cl TOP PLATE 1/4" I TO PIPE CONN. 1 1/4 "x5 3/8 "x0' -11 7/16 ", WELDS TO WF PER CONN. DETAILS 1 3/8 "x3 "x0' -4 ", WELDS TO WF PER 1/S3 AND 2/83 1 3/4 "x24 "x2' -0" PLATE AT TOP AND BTM, AT ANTENNA BASE CONN. THIS PLATE, TYP 3/4" CHAMFER PLATE TYPE El BASE PLATE PER 16/S3 PARTIAL NORTH ELEVATION (8) 1 1/8 "0 BOLT HOLES PLAN VIEW UNDER -SIDE VIEW 1111 eO% / /.i NS Jul I•I PLATE TYPE C2, 17/S3 3/4 "1 BOLT / REF 6/S3 1/4"V CROSS BRACE BEYOND glek TiV CROSS BRACE BEYOND COL PER 5/S2 1/2" CHAMFER COL PER PLAN, 5/S2 2 5/16" 5 11/16" 1 4" 4" 5 11/16" 2 5/16" COL PER PLAN, 5/S2 BEGIN WELD 1/2" FROM EDGE OF PLATE 1/4 BEGIN WELD 1/2" FROM EDGE OF PLATE R 3/4 "x24 "x2' -0" PLATE AT TOP AND BTM, AT ANTENNA BASE CONN. SECTION E 3/16" SECTION F M. ��0•. 1 11M.A.ter•A ANTENNA BASE CONNECTION DETAIL L4x3x1/4 CROSS BRACE ' 3/4 "0 BOLT WF PER PLAN PLATE TYPE B1 BEYOND PER 17/83 AND 6/S3 PLATE TYPE Cl 17/S3 PLATE TYPE El AT TOP TO WF PER 17/S3 AND 2/S3 PARTIAL PLAN COLUMN CONNECTION DETAILS WF PER PLAN SHEAR PLATE TYPE D1 WELD TO WF PER DETAIL 1/S3 --n SECTION B SECTION C BASE PLATE PER 16/83 PLATE TYPE C2 17/S3 L4x3x1/4 CROSS BRACE 1/4" V L4x3x1/4 CROSS BRACE mmismemmer R 3/4 "x24 "x2' -0" PLATE AT TOP AND BTM, AT ANTENNA BASE CONN. EAR PLATE TYPE D1 SHOWN, PER 17/S3 AND PER 1/S3 SCALE 1 1/2" = 1' - 0 PARTIAL WEST ELEVATION bo (;) SCALE J 1/� 0. U ANTENNA BASE ANCHOR BOLTS NOT BY POGGEMEYER DESIGN GROUP; A325 OR A490 1'0 BOLTS TO ANTENNA BASE 3/4 "3 BOLT 3/4 "0 BOLT APR 14 2009 MAR ,1 6 2010 POGGEMEYER DESIGN GROUP 512 Sixth Street S, Suite 202 Kirkland, Washington 98033 p) 425.827.5995 f) 425.828.4850 www.poggemayer.com >- co 6 N I EXPIRES OCTOBER 24, 20101 (I) J F- LU z 0 W z O W I— W W W 0 Q CD O cWd 0 - a_ z D v- Q W O z�N 0 � W W � I---1U z< Q z JOB NUMBER 7094 -A DESIGNED BY BSF DRAWN BY BSF CHECKED BY RDB DATE 12 NOV 2008 SHEET NUMBER S3 OF S6 ! t l i I I i I : : � Q �.�_. § I I Ii it I I I i I " I I I Ii II I Is I I I I I I! [ ■ I I I I I Q `_ I] 0 0 U) U-) LL U) (C CD R 3 /8 "x2 "xLENGTH AT SIDE RAILS R 3/8 "x2 x1 ' - BRACE, (2) LOC. a \ 1/4" V 1/4" V 3/8 "x2 "x1'— SUPPORT S (4) S4 O a T , c.C. 1' -2" a 2" \t— LADDER SIDE ELEVATION RAILING AT UPPER (WORK) PLATFORM PER DETAILS 3/S4, 4/S4, 5/S4 AND LOC. PER 8/S4 2 "0 PIPE I X 8" AT AN RAILING 1/4"V A30: 1/2 "0 BOLT AT a EA. CONN. PLATE AT 1/4 ' LOC., (4) TOTAL TOP OF WF PLATFORM CVL WF SIDE MEMBER OF ANTENNA FRAME, PER PLAN S2 7 3/4" AT W14x38 OR 7" AT W10x19 R 3/8 "x2 "x2" A309 1/2 "0 BOLT AT EA. CONN. PLATE AT WF LOC., (4) TOTAL UPPER (WORK) PLATFORM FRAME, PER SHEET S6, RAILING PER SHEET 3/S4, 4/24, 5/S4 AND 8/S4 � ELEVATION AT RAILING S� NORTH ELEVATION SUPPORT STRUT R 3 /8x2 "xLENGTH N. AT SIDE RAILS SUPPORT STRUT (4) LOC. R 3/8 "x2 "x1' -1/2 , SUPPORT STRUT, (4) LOC. ELEVATION AT RAILING a SCALE 1/2" = 1' -0" 2-0" CLEAR a LADDER DETAIL N LADDER FRONT ELEVATION 6 "j SCALE 1/2 = 1 - 0 " BRACE, (2) LOC. WF 14 SIDE MEMBER OF ANTENNA FRAME, PER PLAN 14 TOP OF WF PLATFORM ft TYP. LADDER RUNG CONN. 1'0 x 2-0" LONG A36, LADDER RUNG AT 12" O.C., TYP, MIN. 12" FROM TOP OF ROOF LADDER AT UPPER (WORK) PLATFORM AND CONN. PER DETAIL 1/S4, LOC. PER 8/S4 LADDER AT UPPER (WORK) PLATFORM AND CONN. PER DETAIL 1/54, LOC. PER 8/S4 PPORT BEAM AND TERAL BRACE AT EACH END, TO 6/S5 SCALE 3/4" = 1' -0" f I • CO 0 0 UPPER (WORK) PLATFORM LADDER ELEVATION 6 "I 0 2 "0 PIPE ( SCHED 40) TYP AT RAIL ALL OTHER NOTES PER TYPICAL DETAIL UPPER (WORK) PLATFORM LVL UPPER PLATFORM C— SECTION, SEE S6 in TOP OF WF PLATFORM LVL — WF AT ANTENNA FRAME LEVEL, REFER TO S6 FIELD VERIFY LENGTH, VARIES AT WF (WHICH IS SKEWED 11' PER PLAN) SOUTH ELEVATION t P � Jt I 2 "0 PIPE (SCHED 40) AT UPPER (WORK) PLATFORM RAILING BASE PLATE ET UPPER (WORK) PLATFORM RANG PER 2/S4, LOC. PER 8/ , TYP. SUPPORT BEAM, TOP OF WF FLUSH WITH TOP OF WF AT ANTENNA FRAME BEYOND ELEVATION AT RAILING RAILING AT UPPER (WORK) PLATFORM PER DETAILS 3/S4, 4/S4, 5/S4 AND LOC. PER 8/S4 7 S4 ELEVATION AT RAILING c ELEVATION AT RAILING WEST ELEVATION PPER (WORK) FRAME, PER AILING PER SH 4/24, 5/S4 (FORM T S6, 3/S4, 8/S4 LADDER AT UPPER (WORK) PLATFORM AND CONY. PER DETAIL 1/54, LOC. PER 8/S4 AND DETAIL C. PER LAD SCALE 1/2" = 1' -0" LADDER AT UPPER (WORK) PLATFORM AND CONN. PER DETAIL 1/S4, LOC. PER 8/S4 IPE ( SCHED T UPPER ) PLATFORM VG SCALE 1/2 = 1 - 0 " I RAILING BASE P AT UPPER (WORK) PLATFORM PER 2/S4 ACCESS LADDER PER DETAIL 1/S4 SWING RADIUS OF ANTENNA (14' -6" DIAM.). LADDERS AND RAILING PROHIBIT THE ANTENNA FROM ROTATION WHEN ANTENNA ANGLE IS LOW 2 1 (4) 5/8 "0 BOLT HOLES; (4) 1/2" A325 BOLTS TYP. R 3/8 "x4 "x0' -6 1/2" RAILING BASE PLATE 6 1/2" 1 1/4" 2 1/4" 2 "0 PIPE ( SCHED 40) TYPICAL AT RAILING 1 1/4" 1 1/4 1 1/4" 2 "0 PIPE (SCHED 40) TYPICAL AT RAILING 7 1/2" 1/48 r BASE PLATE AT UPPER (WORK) PLATEFORM RAIL BASE PLATE DETAILS SCALE 1 1/2" = r -o i f\ir 1 1/4" (2) 5/8 "0 BOLT HOLES; (2) 1/2" A325 BOLTS TYP. ReViLADFOR CODE COMPLIANCE AP PROVED APR 14 2009 City of Tukwila UILDING DIVISION ACCESS LADDER PER DETAIL 1/S4 ACCESS LADDER AT UPPER (WORK) PLATFORM PER 1/S4 CITY OF TUK�VILA FEB 25M N rtri LADDER AND RAILING PLAN $4 SCALE 3/4'= 1 - 0� o �7 P ERMIT A C EMER V POGGEMEYER DESIGN GROUP 512 Sixth Street S, Suite 202 Kirkland, Washington 98033 p) 425.827.5995 f) 425.828.4850 www.poggemayer.com 4, 6 H N I EXPIRES OCTOBER 24, 20101 0 z J z w J J LiJ W UJ �j U 0 QW O O I � I D (r) W z�N W -1 U z Q CD z CO JOB NUMBER 7094 -A DESIGNED BY BSF DRAWN BY BSF CHECKED BY RDB DATE 12 NOV 2008 SHEET NUMBER S4 O1= S6 ci (1 Ci 74 r_n Li Q) 0 a.. 0 c N LU a 0 a 0 n C VJ f1 ei 'v 6_ U- 0 0 a (, D_ ,NNWI �: .00m .3�e. ❖. .;.•s.:•.a•: • •. OVVVVVOW y i i! i.�.�; ..:......... NORTH ELEVATION SCALE 1/8" = 1' -0" SOUTH ELEVATION SCALE 1/8" = 1' -0" .•ii! . • • MI EAST ELEVATION SCALE 1/8" = 1' -0" WEST ELEVATION SCALE 1/8" = 1' -0" MAR ,16 2010 RECEIVED CITY OF TUKWILA FEB 2 52009 PERMIT CENTER POGGEMEYER DESIGN GROUP 512 Sixth Street S, Suite 202 Kirkland, Washington 98033 p) 425.827.5995 0 425.828.4850 www.poggemeyer.com ■ m O CV a) co L ■ I EXPIRES OCTOBER 24, 20101 z O F- w w J 0 J J w (n -i w w O Q w O Ch CD (h O w d O f • 0_ Z Q w O z �N z < F— CD JOB NUMBER 7094 -A DESIGNED BY BSF DRAWN BY BSF CHECKED BY RDB DATE 12 NOV 2008 SHEET NUMBER S5 OF S6 u TOP OF SUPPORT BEAM FLUSH WITH TOP OF ANTENNA FRAME WIDE FLANGE LEVEL COLUMN SHOWN BEYOND A53 GR B PIPE 3 1/2 "0, TYP A36 C7x12.2 COLUMN SHOWN BEYOND A53 GR B PIPE 3 1/2 "0, TYP WORK PLATFORM SUPPORT BEAM, REFER TO PLAN 6/S6 EXISTING 16K4 JOISTS AT 5' -0" PLATE TYPE C3 DETAIL 17/S3 L4x3x1/4 BRACING 3 1/2 "--/ BASE PLATE TYPE A2 PER DETAIL 16/S3 AMR A —. A A— A AMR M.— A A A TE TYPE C2 17/83 MIR 0 a 0 LU 0 U7 a- 0 0 0 L) r = - -. U 0) U L a_ a 1 f -. AEI 3' -0" A36 C7x12.2 _At WORK PLATFORM SUPPORT BEAM SCALE: 3/4" = 1' -0" COLUMN SHOWN BEYOND A53 GR B PIPE 3 1/2 "0, TYP 3' -0" TO OF UPPER (WORK) PLATFORM SUPPORT COL UPPER (WORK) PLATFORM SUPPORT COL: A53 2 "XS P INV WORK PLATFORM PLAN SCALE 3/4" = 1' -0" (2) 1/2 "0 A325 BOLTS, ANGLE TO CHANNEL SECT. C SECT. AT WORK PLATFORM FRAME CONN. PLAN VIEW UPPER (WORK) PLATFORM SUPPORT COL: A53 GR B 2 "XS PIPE (TYP.) ANGLE CONN. PER DETAIL 5 /S6 (2) 1/2 "0 A325 BOLTS, ANGLE TO WF SECT. SCALE: 11/2" = 1' - DEPENDS ON 1 LEG OF ANGLE FLASHING AND WATERPROOFING NOT BY POGGEMEYER BASE PLATE TYPE A2 PER DETAIL 16/53 5/8 "0 BOLT HOLES FOR 1/2 "0 A325 BOLTS, TYP. ANGLE CONN. CO UPPER (WORK) PLATFORM SUPPORT COL: A53 GR B 2 "XS PIPE (TYP.) WF OR TS AT ANTENNA FRAME PER 5/S2 OR SUPPORT BEAM PER 6/S6 , • ..� 1 -- 1/2" A36 ANGLE 1 3/8" 2 1/2" 1 3/8" C SECT. AT WORK PLATFORM FRAME 1/4" a -,- - '!! ------- - - - - -- -- - - - - -I IW CHANNEL AT WORK PLATFORM FRAME S6 L5x3x1/4 x 5 1/4" LENGTH ANGLE AT SHEAR TAB CONN., TYPICAL AT WORK PLATFORM FRAME 1/4" 1/4 WF AT ANTENNA FRAME PER PLAN 5/S2 BRACE AT ENDS ONLY CROSS (2) 1/2 "0 A325 BOLTS, ANGLE TO CHANNEL SECT. C SECT. AT WORK PLATFORM FRAME SECTION A WORK PLATFORM CONN. PLAN VIEW CHANNEL AT UPPER (WORK) PLATFORM PER 7/S6 CHANNEL TO TOP PLATE CONN. 3" 1/2" drdr CHAMFER 3 1/2" TOP PLATE WORK PLATFORM SUPPORT COL. r rr 7 I . _ 3 SCALE 1 1/2" = COL PER PLAN 7/S6 SECTION DETAIL ANGLE CONN. PER DETAIL 5/S6 (2) 1/2 "0 A325 BOLTS, ANGLE TO WF SECT. A36 1 3 1/2x3 1/2x3/8, 1/2" CHAMFER AT EXPOSED EDGES, TOP OF EA. WORK PLATFORM SUPPORT COL SCALE 1 1/2" = 1' -0" ti SCALE: 1 1/2" = 1' -0" REVIE CODE CO PLIANCiE APR 14 2009 City of Tukwila BUILDING DIVISION 1/4" WF PER 6/S6 1/4°V 5/8 "0 BOLT HOLES FOR 1/2 "0 A325 BOLTS, TYP. ANTENNA SUPPORT FRAME NORTH ELEVATION s_6} (SOUTH rye -.new SIMILAR) 1 3/4" (2) 1/2 "0 A325 2 1/4" ANGLE CONN: BOLTS, ANGLE TO L1/4 "x4 "x4" BY CHANNEL SECT. O' -5 1/4" LENGTH 1 3/8" 2 1/2" 1 3/8" ANGLE CONN. C SECT. AT WORK PLATFORM FRAME ANGLE CONN.: AT SHEAR TAB CONN., TYPICAL AT WORK PLATFORM WF AT WORK PLATFORM FRAME (2) 1/2 "0 A325 BOLTS, ANGLE TO WF SECT. SUPPORT BRACE CONN. PLAN VIEW ANTENNA SUPPORT FRAME WEST ELEVATION (EAST ELEVATION SIMILAR) SCALE: 3/4" = 1' -0" SC 1,_0. 041. SCALE 1 1/2" = C F PLATE TYPE C2 DETAIL 17/S3 POGGEMEYER DESIGN GROUP 512 Sixth Street S, Suite 202 Kirkland, Washington 98033 p) 425.827.5995 f) 425.828.4850 www.poggemeyer.com m O 0 N I EXPIRES OCTOBER 24, 20101 z 0 I bJ z z J a_ LU W W� U Q l L < W O I- 0_ z L; D r VJ Q WO z O c' c W L ZL I -1 z z S2 0 -i co JOB NUMBER 7094 -A DESIGNED BY BSF DRAWN BY BSF CHECKED BY RDB DATE 12 NOV 2008 SHEET NUMBER SE OF S6