Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D09-033 - BROADSTRIPE - NON-BEARING WALLS AND LIGHTING
BROADSTRIPE 4345 S 104 PL D09 -033 Parcel No.: 0323049026 Address: 4345 S 104 PL TUKW Suite No: doc: IBC -10/06 CityOf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: BROADSTRIPE Address: 10400 MARTIN LUTHER KING WAYS , TUKWILA WA Owner: Name: SEBCO INC Address: 4020 E MADISON #320 , SEATTLE WA 98112 Phone: Contact Person: Name: DAVID KEHLE Address: 1916 BONAIR DR SW , SEATTLE WA 98116 Phone: 206 - 433 -8997 Contractor: Name: PRECISION BUILDERS INC Address: PO BOX 98609 , DES MOINES WA 98198 -0609 Phone: 206 878 -2948 Contractor License No: PRECIBI151C2 DEVELOPMENT PERMIT DESCRIPTION OF WORK: REMOVE EXISTING NON BEARING WALLS AND INSTALL NEW NON - BEARING WALLS, DOORS, RELOCATE LIGHTS. NO CHANGE TO BUILDING ENVELOPE Value of Construction: $63,000.00 Fees Collected: $1,719.18 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: V -B Occupancy per IBC: 0008 * *continued on next page ** Permit Number: D09 -033 Issue Date: 03/19/2009 Permit Expires On: 09/15/2009 Expiration Date: 01/19/2010 D09 -033 Printed: 03 -19 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Signatu Print Name: doc: IBC -10/06 City o 11 ukwila S Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us aird.A --tea 1/-03D Permit Number: D09 -033 Issue Date: 03/19/2009 Permit Expires On: 09/15/2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The grantin• • f 's permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructi j ; performance of world I am authorized to sign and obtain this development permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -033 Printed: 03 -19 -2009 Parcel No.: 0323049026 Address: 4345 S 104 PL TUKW Suite No: Tenant: BROADSTRIPE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D09 - 033 Status: ISSUED Applied Date: 03/11/2009 Issue Date: 03/19/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 D09 -033 Printed: 03 -19 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3- 2.1)(Office area) 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3- 2.1)(Warehouse area) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be doc: Cond -10/06 D09 -033 Printed: 03 -19 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 29: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 31: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 34: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 36: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 -575 -4407 for ordering information. 37: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. The lockbox should be mounted so that it is readily visible and not over 60 inches high. (City Ordinance #2051) 38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 39: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 40: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth doc: Cond -10/06 D09 -033 Printed: 03 -19 -2009 in Table No. 803.5 of the International Building Code. • S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 41: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 42: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 43: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 44: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * * continued on next page ** D09 -033 Printed: 03 -19 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature. Print Name: .a) (2),(ve,ao //I.Qr,31) TR Ver•5O doc: Cond -10/06 D09 -033 Date:8 — 0 - 6, ordinances governing or local laws regulating Printed: 03 -19 -2009 CITY OF TUKWIL4 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http.-4/www.ci.tukwila.wa.us Name: David Kehle Mailing Address: 1916 Bonair Drive SW E Address: dkehle @dkehlearch.com Company Name: David Kehle, Architect Mailing Address: 1916 Bonair Drive SW Contact Person: Dave Kehle E Address: dkehle @dkehlearch.com Building Permit No. 'V -() 3 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION c , I tA ch. Site Address: er Tenant Name: Broadstripe Property Owners Name: SEBCO - Jay Blasingame Mailing Address: 4020 East Madison Street King Co Assessor's Tax No.: 03 - 2304 - 9026 - Suite Number: Floor: New Tenant: ❑ Yes ❑ ..No Seattle City WA State 98112 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued To Be Determined Contact Person: E-Mail Address: Contractor Registration Number: Day Telephone: (206) 433 -8997 Seattle WA 98116 City State Fax Number: (206) 246 -8369 Seattle State City State Day Telephone: (206) 433 -8997 Fax Number: (206) 246 -8369 State Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record WA 98116 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: x:lAyyhcaSooaVF0ms-Apphm6ms On L ne\2009 Applicationa\1 -2009 - Pemit Appticatien.doe Revised: 1 -2009 bit Zip Page 1 of 6 BUILDING PERMIT INFO ' TION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 63,000 Existing Building Valuation: $ Scope of Work (please provide detailed information): Remove existing non - bearing walls and install new non - bearing walls, doors, re- locate lights. No change to building envelope Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Bfr low PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 11:1Applicatio sWonns- Applications On Ime12009 Appfication, ■1 -2009 - Permit Appdicatioa.doc Revised: 1-2009 hh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor 9,191 4,341 V -B Sprink B, S1 2 Floor 3' Floor Floors thru Basement Accessory Structure' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFO ' TION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 63,000 Existing Building Valuation: $ Scope of Work (please provide detailed information): Remove existing non - bearing walls and install new non - bearing walls, doors, re- locate lights. No change to building envelope Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Bfr low PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 11:1Applicatio sWonns- Applications On Ime12009 Appfication, ■1 -2009 - Permit Appdicatioa.doc Revised: 1-2009 hh Page 2 of 6 Date Application Accepted: 3 1 �0 9 Date Application Expires: t...1 I � Staff Initials: Li l I PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. $uildina and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. i BUILDING OWNER OR ACTH Signature: Print Name: David Kehl Day Telephone: (206) 433 -8997 Mailing Address: 1916 Bonair Drive SW H: ApplicationsWonno-Applientions On Line \2009 Application \1 -2009 - Ilamit Application.doc Revised: 1 -2009 bh Seattle City Date: 03/09/2009 WA 98116 State Zip Page 6 of 6 Payee: DAVID KEHLE ARCHITECTS ACCOUNT ITEM LIST: Description • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 0323049026 Permit Number: D09 -033 Address: 4345 S 104 PL TUKW Status: APPROVED Suite No: Applied Date: 03/11/2009 Applicant: BROADSTRIPE Issue Date: Receipt No.: R09 - 00444 Payment Amount: $1,043.70 Initials: WER Payment Date: 03/19/2009 03:21 PM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 18570 1,043.70 BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 640.237.114 RECEIPT Account Code Current Pmts 1,039.20 4.50 Total: $1,043.70 doc: Receiot -06 Printed: 03 -19 -2009 Payee: DAVID KEHLE ARCHITECTS ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 18560 675.48 RECEIPT Parcel No.: 0323049026 Permit Number: D09 -033 Address: 10400 MARTIN LUTHER KING WY S TUKW Status: PENDING Suite No: Applied Date: 03/11/2009 Applicant: BROADSTRIPE Issue Date: Receipt No.: R09 - 00392 Payment Amount: $675.48 Initials: WER Payment Date: 03/11/2009 09:39 AM User ID: 1655 Balance: $1,043.70 Account Code Current Pmts 000/345.830 675.48 Total: $675.48 doc: Receiot -06 Printed: 03 -11 -2009 Proj t; J Type of pectin ` I 1 9 1 7 Address: Date Called: Special Instructions: Date Wanted: 3 2f - c`3 /a p.m. Requester: Phone_No: ' 311 _ ( 5 O INSPECTION NO. INSPECTION RECORD Retain a copy with permit bag -6 33 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. EI Corrections required prior to approval. COMMENTS: (,c). 2ref ,a.(j A e L ip( Th Inspector Date: 7 q 7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pro ect: UVOAt,c. f ; pE Type of Inspection: 'J(, CLAZ( 1 1=iNq ( Address: I— ) 3 L iS S j aq Date Called: Special Instructions: � T r I� ���SZ ' S ; i l � • �A �,�/.1 "`� Date Wanted: ^ 0c — ) 3 7 �a tY1y p.m. Requester: b IV J. kh S wit' r *r �, SC- INSPECTION RECORD Retain a copy with permit yu' , . . t v'c Approved per app codes. Cj Dcfi -03 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ri $60.0 REINSPECTIGN FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: r 4 . Inspector rate: .3 orrecti I s required prior to approval.* ,-J E Ge)`f rA id/...i COMMENTS: Type o Inspection: < <.Aw j) i1 ■ rQ ■ S A / e. Th A re A∎ntiA!! (.. T -r Mr f kr 4 1A.eSS1( ' _ P 0,019Q J f I1 +/ A l� 3s1.(S S t `l p ;„ -�' ../ 434S e i )_PiA4;; — 1Jk. t S ; ' Special Instructions: 2)( ;A r Sui p 4 e, I ' r,i ;____,...5 p P. c.`Im p.m. Requester: Phone No: ( 6 —I ? 0 Project: • f"r0 �cls {v l p-v Type o Inspection: < <.Aw A l� 3s1.(S S t `l p Date Called: Special Instructions: Date Wanted: l 5 I 1 I / 0 9 p.m. Requester: Phone No: ( 6 —I ? 0 PERMIT NO. , CITY OF TUKWILA BUILDING DIVISION • P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. INSPECTION RECORD Retain a copy with permit bog-033 ❑ Approved per applicable codes. Corrections required prior to approval. Date: 5 , I ( -o 4 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Pro ect: V I OAC_C.S r i ptc Type of Inspection: FR Any t n1 Address: L-13 LIS ' ► o 4 i'(— Date Called: Special Instructions: Date Wanted: 2�jj ' 3 I — V p.m. sfr: Requee . Phone No: 20 - 3c6v . - /S i _____,,---- INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 D$69-0,3 5 PERMIT NO. P (206)431-3670 roved per applicable codes. COMMENTS;, Inspect Dad�_jj e: : 7 .00 REINSPECTION F =E REQUIR . Prior to inspection, fee must be id at 6300 Southcenter lvd., Suit- 100. Call to schedule reinspection. Receipt No.: Date: El Corrections required prior to approval. COMMENTS: Type of Inspection: - F R Aryl! A)C, Address: I-13 45 S I I3L( PL AI ( 6 L/kt Special Instructions: c DA-le'ro4 Date Wanted: 3 -2. off- "T -- z) 09) s o k— — Phone No: --d _ � ► 50...4 (J I M 36 f?w 6-fr.' G l r ,_J `" CAc(•( T v r r e- Q ` , ,6r7 / P c..P . G ,� t, A n Project: GPaA'l v-c-1y1pE, Type of Inspection: - F R Aryl! A)C, Address: I-13 45 S I I3L( PL Date Called: Special Instructions: Date Wanted: 3 -2. � a.rrt) 7 - d `l . Requester: Phone No: --d _ � ► 50...4 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. Inspe;'ctor: Date:3 n J f � INSPECTION RECORD Retain a copy with permit - 3 3 PERMIT NO. Corrections required prior to approval. • L $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: F act 1 ,"'rt . Type of Inspection: 5 ,- , �1..),r,�. /E - 17 f Address: Suite #: / o Z ? G� IVI Contact Person: ,/Q 1`,l Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 a Al; roved per applicable codes. INSPECTION RECORD Retain a copy witirpermit CITY OF TUKWILA FIRE DEPARTMENT o9 -- .5 ©Y� PERMIT NUMBERS Corrections required prior to approval. COMMENTS: s - ) CC7 �r ✓�) 7 �GU / ' e1 G J C/_)01--.1 Inspector: 51 Date:'' f �. J , : rs.. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Protect: l 6 r'o �t R I�Pe Sprinklers: Type of Inspection: t_. n Address: `�y`�� Suite #: ���� Con Person: Special Instructions: ', Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER Approved per applicable codes. , RECORD Retain a copy with permit word /Inspection Record Form.Doc 1/13/06 p dcp -d �3 PERMIT NUMBERS/ CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 ri Corrections required prior to approval. COMMENTS: /l 1 Date: y4 � / ' H rs.: $80.00 REINSPECTION FEE REQUIRED: You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: j ,to A o5-rra. t 1 u Sprinklers: Type of Inspection: Address: lo 'l 2 Suite #: M Lt< W Y Contact Person: Jf 14vJr -k � /vvrat1e , Special Instructions: Phone No.: 200 '763 58 o Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre- Firer Permits: _ Occupancy Type: INSPECTION NUMBER n Approved per applicable codes. r:L / Word /Inspecction Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East T ukwila, W 981 88 2D6- 575 - 4407 COMMENTS: &ZA t E. -1 L i -r- W o 12-1 Date: 3/01 1)04 - Q 33 01- 5 auto PERMIT NUMBERS .Corrections required prior to approval. $80.00 REINSPECTION FEE REQUIRE©. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. 1/13/06 T.F.D. Form F.P. 113 Project Info Project Address ej„ YY//�G Date /33 l:1 IA t 1 v'.. hl 4. //:;.• For Building Depa ent Use Watts Proposed Applicant Name: n At Applicant Address: tt , I %, , l a, _Fe -4y lit , 4g1 . 33 -ti ill Applicant Phone: Project Description ❑ New Building ❑ Addition Alteration ❑ plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ess than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft " Area in ft Allowed x Area Watts Proposed CO DE I YY� C D E/ COMPup CE " From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts AP Location (floor /room no.) Fixture Description Number of - - Watts/ Fixture Watts Proposed CO DE I YY� C D E/ COMPup CE AP RCN D MAR 17 2009 City of Tu kwila BUII DINS D IVI�1CAl Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2006 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Provosed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form •,Interio.r Lighting'S;umm LTG -INT Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. VElza - U 14 tittlIKT DOq- 033 Revised Jury 2007 RECEIVED MAR 112009 r'EHrvMIT CENTEF Opaque Concrete /Masonry Wall Requirements Wall Maximum U- factor is 0.15 (R5.7 continuous ins) CMU block walls with insulated cores comply If project qualifies for Concrete /Masonry Option, list walls with HC >_ 9.0 Btu /ft . °F below (other walls must meet Opaque Wall requirements). Use descriptions and values from Table 10-9 in the Code. Wall Description (including insulation R -value & position) U- factor For Building De �� � rw t Use �� ii. ®1 r , _ rr i • — o Applicant Address:1 Iw P,oN61Q j2 5W ailt ite �V,6 lti r A 1 Applicant Phone: - / AAA A 0 !ED I/ a a rr - Ci of , .. .,. -_ W1 Project Info . Project Address (fxJn[ // V �frtrt Date ,� l Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing �O .4A 1 � t �wll77 V WIIA1 u o' For Building De �� � rw t Use �� ii. ®1 O yes Check here if using semi - heated path and if project meets all requirements for semi- heated spaces Semi- Heated Path O no as defined in section 1310. Requires other fuel, heating and qualifying thermostat Only wall insulation requirement is reduced (2006 change). Only available in prescriptive path. Of- Applicant Name: ailb wi Applicant Address:1 Iw P,oN61Q j2 5W ailt ite �V,6 lti r A 1 Applicant Phone: - / AAA A Space Heat Type 0 Electric resistance 0 All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing — X 1 00 = Concrete/Masonry Option 0 yes Check here if using this option and if project meets all requirements for the Concrete/Masonry Ono Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying assembly below. O yes Check here if using semi - heated path and if project meets all requirements for semi- heated spaces Semi- Heated Path O no as defined in section 1310. Requires other fuel, heating and qualifying thermostat Only wall insulation requirement is reduced (2006 change). Only available in prescriptive path. 2006 Washington State Nonresidential Energy Code Compliance Form 'Envelope Summary, CI,imOe Zone ENV -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Description ❑ New Building ❑ Addition ❑ Alteration ❑ Change of Use Compliance Option ❑ Prescriptive ❑ Component Performance (See Decision Flowchart (over) for qualifications) ❑ Seattle EnvStd ❑ Systems Analysis Envelope Requirements (enter values as applicable) Minimum Insulation R- values Roofs Over Attic All Other Roofs Opaque Walls' Below Grade Walls Floors Over Unconditioned Space Slabs -on -Grade Radiant Floors Opaque Doors Vertical Glazing Overhead Glazing Maximum U- factors Maximum SHGC (or SC) Vertical/Overhead Glazing 1. Assemblies with metal framing must comply with overall U- factors Notes: Np 01'4 1 r. -1'. 1t vto v tDO' RECEIVED MAR 112009 PERMIT CENTER Envelope; Summ (back) Climate Zone .1 ENV -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Decision Flowchart for Prescriptive Option Use this flowchart to determine if project qualifies for the optional Prescriptive Option. If not, either the Component Performance or Systems Analysis Options must be used. 1302 Space Heat Type: For the purpose of determining building envelope requirements. the following two categories comprise all space heating types: Other. All other space heating systems including gas, solid fuel, oil, and propane space heating systems and those systems listed in the exception to electric resistance. (continued at right) PERMIT CENTEF All Insulation Installed? Below Grd Wall (ext) R -10 Below Grd Wall (oth) R -19 Roof Over Attic R -30 All Other Roof R -21 Raised Floor R -19 Slab -On -Grade R -10 Radiant Floor R -10 Opaque Door U -0.60 0] L Mass Wall Criteria OK? (below) Yes AG Mass Wall Insulation Req. Mass Wall CMU Block Wood Frame Metal Framed U0.15/R5.7ci Ins. Cores R19 R19 , 2006 Washington State Nonresidential Energy Code Compliance Form es Ye Glazing Vert OH Area % UVaI UVaI 0-30% 0.55 0.70 30-45% 0.45 0.60 >45% Not Allowed No Yes Glazing Criteria Met'? Yes I 1, SHGC 0.45 0.40 Prescriptive Path Allowed Component Performance, Systems Analysis, or EnvStd Required Electric Resistance: Space heating systems which use electric resistance elements as the primary heating system including baseboard, radiant, and forced air units where the total electric resistance heat capacity exceeds 1.0 W/ft of the gross conditioned Floor area. Exception: Heat pumps and terminal electric resistance heating in variable air volume distribution systems. Yes Glazing Criteria Met? Yes s All Insulation Installed? Below Grd Wall (ext) Below Grd Wall (oth) Roof Over Attic All Other Roof Raised Floor Slab -On -Grade Radiant Floor Opaque Door Wood R -10 R -19 R -38 R -30 R -30 R -10 R -10 U -0.60 Metal R -10 U -0.062 U -0.031 U -0.034 U -0.029 R -10 R -10 U -0,60 Ye Yes— Glazing Vert OH Area % UVaI UVaI SHGC 0 -30% 0.40 0.60 0.40 >30 Not Allowed No Yes Concrete/Masonry Option* Assembly Description RE!CO/ MAR 112009 Wall Heat Capacity (HC) Assy.Tag HC" Totals Area (sf) Area weighted HC: divide total of (HC x area) by Total Area HC x Area N Nt» 4 AG Mass Wall Insulation Req. Mass Wall U0.15 /R5.7ci CMU Block Ins. Cores Wood Frame R19 Metal Framed U0.062 Revised July 2007 if the area weighted heat capacity (HC) of the total above grade wall is a minimum of 9.0, the Concrete Masonry Option may be used. For framed walls, assume HC =1.0 unless calculations are provided; for all other walls, use Section 1009. ACTIVITY NUMBER: D09 -033 PROJECT NAME: BROADSTRIPE SITE ADDRESS: X Original Plan Submittal Response to Correction Letter # Revision # DATE: 03 -11 -09 - '.T Response to Incomplete Letter # After Permit Issued DEPARTMENTS: Building Division Public works DETERMINATION OI COMPLETENESS: (Tues., Thurs.) Complete Comments: PLAN Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RQ►UTING: Please Route Documents/routing slip.doc 2 -28 -02 sll *'1 Jr Fire Prevention Structural Incomplete Structural Review Required ING SLIP 0(A 0 >l 2• O1 Planning Division n Permit Coordinator DUE DATE: 03-12-09 Not Applicable No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04 -09-09 Approved ❑ Approved with Conditions N ot Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW El Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 DEVELOPERS INS CO 415171 C 01 /19/2002 Until Cancelled Date Date $12,000.00 01/14/2002 3 DEVELOPERS SURETY Et INDEM CO 415171C 01/19/1998 01/19/2002 $6,000.00 08/08/2001 2 DEVELOPERS INS CO 415171C 01/19/199601/19 /1998 $6,000.00 1 AMERICAN STATES INS CO EX51675901/19/198501/19/1996 $6,000.00 Name Company Policy Effective Expiration Cancel Impaired Received Insurance Name Number Date Date Date Date Amount Date Name Role Effective Date Expiration Date SANBURN, SCOT D AGENT 02/22/1985 Untitled Page General /Specialty Contractor A business registered as a construction contractor with Lftl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company PRECISION BUILDERS INC 2068782948 PO BOX 98609 DES MOINES WA 981980609 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 600553713 ACTIVE PRECIBI151 C2 CONSTRUCTION CONTRACTOR 2/22/1985 1/19/2010 PRECIB*163BR WESTCBI133M3 GENERAL UNUSED Business Owner Information Bond Information Insurance Information 0 • Page 1 of 2 https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= PRECIBI151 C2 03/19/2009 BOEING* ACCESS ROAD 5. VICINITY MAP SCALE: NTS NORTH BUILDING AND SITE STATISTICS L BUILDING CODE' IBC 2006 W/ STATE AMENDMENTS 2. ZONING: LI 3. TYPE OF CONST.: V -B SPRINKLERED 4. OCCUPANCY GROUP' B, S -1 5. AREA OF REMODEL: 4,341 SF 6. AREA OF TENANT' 9,191 SF 7. AREA OF BUILDING: 29,188 SF 3 TAX ID NUMBER: 03 - 2304- 9026 -07 LEGAL DESCRIPTION (TRANSNATION TITLE NO 869712) PARCEL Al THAT P❑RTI ❑N OF THE NORTHWEST 1/4 OF THE SOUTHEAST 1/4 AND THE NORTHEAST 1/ OF THE SOUTHWEST 1/4 OF SECTION 3, TOWNSHIP 23 NORTH, RANGE 4 EAST WM., DESCRIBED AS FOLLOWS: BEGINNING AT THE INTERSECTI ❑N OF THE NORTH LINE OF SAID NORTHWEST 1/4 WITH THE WEST MARGIN OF EMPIRE WAY SOUTH (SAID WEST MARGIN BEING 60 FEET FROM THE MONUMENT LINE THEREOF); THENCE NORTH 86° 58' 28' WEST ALONG THE NORTH LINE OF SAID NORTHWEST 1/4 AND NORTHEAST 1/4 650.94 FEET; THENCE SOUTH 03° 01' 32' WEST 249,89 FEET TO THE NORTH MARGIN OF THE BOEING ACCESS ROAD INTERCHANGE; THENCE NORTH 63° 46' 45' EAST ALONG SAID NORTH MARGIN 52.03 FEET TO A PINT OF CURVATURE OF A 325 FOOT RADIUS CURVE TO THE RIGHT; THENCE ALONG SAID MARGIN AND CURVE 635.7 FEET TO A POINT OF TANGENCY ON THE EAST MARGIN OF SAID BOEING ACCESS ROAD; THENCE SOUTH 04° 06' 30' EAST ALONG SAID MARGIN 134.84 FEET; THENCE NORTH 85° 53' 30' EAST ALONG SAID MARGIN 64,41 FEET; THENCE NORTH 34° 02' 42' EAST 133.42 FEET TO SAID WEST MARGIN OF EMPIRE WAY SOUTH; THENCE NORTH 00° 02' 44' EAST ALONG SAID WEST MARGIN 480.68 FEET TO THE POINT OF BEGINNING; SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. PARCEL B: (TITLE REPORT ITEM '9' ) EASEMENT RIGHTS FOR AN UNDERGROUND SEWER LINE AS CONTAINED IN EASEMENT AGREEMENT RECORDED UNDER RECORDING NO. 7107090609) SAID EASEMENT BEING DESCRIBED AS FOLLOWS: THE WEST 6 FEET OF THE SOUTH 360 FEET OF THAT PORTION OF THE 'CITY' LAND DESCRIBED AS FOLLOWS: THAT PORTION OF THE SOUTHWEST 1/4 OF THE NORTHEAST 1/4 OF SECTI ❑N 3, TOWNSHIP 23 NORTH, RANGE 4 EAST W.M„ LYING WESTERLY OF EMPIRE WAY, AS ESTABLISHED BY CONDEMNATION ORDINANCE NO. 53314; EXCEPT THE NORTH 60 FEET THEREOF; SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. PARCEL C: (TITLE REPORT ITEM '10' ) EASEMENT RIGHTS FOR AN UNDERGROUND SEWER LINE AS CONTAINED IN SEWER LINE EASEMENT RECORDED UNDER RECORDING NO. 7110190463, SAID EASEMENT BEING DESCRIBED AS FOLLOWS' A STRIP OF LAND 6 FEET IN WIDTH AS MEASURED AT RIGHT ANGLES FROM AND LOCATED IMMEDIATELY SOUTH OF THE NORTHERLY LINE OF THE FOLLOWING DESCRIBED PROPERTY IN THE NORTHWEST 1/4 OF SECTION 3, TOWNSHIP 23 NORTH, RANGE 4 EAST W.M., IN KING COUNTY, WASHINGTON, WHICH NORTHERLY LINE IS DESCRIBED AS FOLLOWS: BEGINNING AT THE CENTER OF SAID SECTION 3; THENCE NORTH 00° 23' 13' EAST ALONG THE NORTH -SOUTH CENTER LINE OF SAID SECTION 360 FEET TO THE POINT OF BEGINNING OF THE NORTH LINE TO BE DESCRIBED, BEING THE NORTHEAST CORNER OF GRANTOR'S SAID REAL PROPERTY) THENCE NORTH 89° 36' 47' WEST AT RIGHT ANGLES 175 FEET TO THE EAST MARGIN OF 40TH AVENUE SOUTH AS DEFINED IN CITY OF SEATTLE A. 0, 95900, BEING THE NORTHWEST CORNER OF GRANTOR'S SAID REAL PROPERTY AND THE WESTERLY END OF THE NORTH LINE TO BE DESCRIBED; SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGT ❑N. 439.6' BLDG. ",4" 4344 5 104TH PL 48.92' 97.74' BLDG. "B° 10401 MLK JR WAY AREA of IMPROVEMENT EX. ASPHALT PARKING* LOT EX PARKING EX PAWING EX. PARKING LOT 39' -H" 39' -6@" N85'S3'30 "E SCOPE: REMOVE EX NON - BEARING WALLS AND INSTALL NEW NON - BEARINGS WALLS, DOORS, RE LOCATE LIGHTS. NO CHANGE TO BUILDING ENVELOPE. SEFERAT N PERMITS: HVAC MODIFICATIONS, ELECTRICAL AND SPRINKLER MODIFICATIONS WILL ABE UNDER SEPERATE PERMITS THAROUGI4 THE CONTRACTORS. SITS PLAN SCALE: I" ■ 40' -0" NORTH 5 86'5828" E 65094' D ef t R 4. 2 .5 ' 0/1 o � /? 0 8 3 s • 1 6 Is REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit Na__12 Plan review approval is subject to enoas and omissions. Approval of construction documents does not authorize the violation of any coda or ordinance. Receipt r � , " : is acknowledged: R-7 City Of Admits BUILDING DIVISION 0' 20' 40' 60' SCALE 1" = 40' SEPARATE PERMIT REQUIRED FOR: l` 4 Mechanical Electrical Plumbing I Gas Piping City of Tukwila BUILDING DIVISION B tn 100' 64.5' 140' CONC. WALL 0� MU) 60' 60' I 044 k 04 RECEIVED MAR 112009 PERMIT CENTEF b0033 ifa 'VISION N CO 0 CO M t G N Lit CD 0 0 N N CO W hoe 0x � O � W ( � IFA3 0 co _ z SD 1 Z: \CAD \2009 \0902 LINDAL- BROADSTRIPE BLDG B \CD'S \SD- 1.dwg, 3/10/2009 10:47:52 AM, Designiet 500 MAIN.pc3 2 -10 A. UJALL TYPE NEW 3 5/S" X 25 GA. STEEL STUD AT 24" 0.C. TO CEILING, WIN 5/8" GYP BD. EACH SIDE, SOUND INSULATE WALL AND CEILING FOR 24 " E.S. ROOM SCHEDULE (EE = EGGSHELL ENAMEL) -11 FLOOR: NEW 30 OUNCE CARPET, DIRECT GLUE (REMOVE EX.) BASE: 4" RUBBER, CONTINOUS WALLS: PAINT (EE) CEILING: EX. SUSP. ACOUSTIC + 9'AFF DOOR SCHEDULE (LEVER HANDLES ON ALL DOORS) E ALL E DOORS ARE EXISTING, REKEY AS REQUIRED 1 NEW 3'- 0 "XT -0" S.C. WOOD (STAIN) W/UJOOD JAMB (STAIN) (MATCH EXISTING W/ I,J" PAIR BUTTS, LOCKSET, WALL STOP NEW 3' -0" X 1' -0" S.C. WOOD (STAIN) W/WOOD JAMB (STAIN), (MATCH EXISTING) W/ I Y" PAIR BUTTS, LOCKSET, SILENCERS,WALL STOP, AND 24" X 30" SAFETY CLEAR GLAZING IN WOOD JAMB FRAMES AND DOORS TO MATCH EXISTING UJOOD FRAME DETAIL SCALE: I -1/2" a 1' -0'I UJALL TO MULLION SCALE: 1 -1/2" a 1 -0 STUD UJALL (SEE SCHEDULE) 2x WOOD BLOCKING 2 1/2" WOOD CASING - STAINED I I/2" x WOOD JAMB - STAINED 5/8" x WOOD STOP - STAINED SOLID CORE WOOD DOOR STAINED 5/8" GYP BD. EACH SIDE 5/8" GYP. BD. BOTH SIDES STL. STUD * 24" O.C. CAULK BACKER ROD FOAM TAPE ANODIZED ALUM. STOREFRONT W/ I" INSULATED GLASS PAINT STEEL STUD TO MATCH MULLION COLOR SECTION SECTION 50' NEW OFFICE NEW OFFICE & NEW OFFICE e NEW OFFICE 6 � NEW OFFICE SPRINKLER NEW OFFICE OPEN OFFICE EMERGENCY PATHWAY LIGHT EMERGENCY PATHWAY LIGHT EMERGENCY PATHWAY LIGHT EMERGENCY PATHWAY LIGHT NORTH Pg ■ \ EXIT TRAVEL DISTANCE \ IS AT 100 LF. WAREHOUSE \ 4,283 S.F. 1/500 : 8 OCCI.IPANTS ONE EXIT REQUIRED \ SCALE I /8" : 1' -0" \ \ \ \ COR AN 1 44' -9? ENERGY CODE NOTES I) HEAT IS VIA GAS, NO ELECTRIC HEAT ALLOWED 2) PROVIDE VAPOR ON ALL WALL TO THE WARM SIDE 3) CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES INCLUDING WEATHER- STRIPPING AT ALL EXTERIOR DOORS. 4) MAXIMUM ALLOWABLE LOAD FOR SWITCH IS 80% OF 20 AMP CIRCUIT. 5) PROVIDE DUAL LEVEL SWITCHING IN ALL ROOMS ADJACENT TO EXTERIOR WINDOWS 6)NO CHANGE TO EXTERIOR ENVELOPE • —IN M -KO N cY1 1 T V —1N R VIEWED Fr COD MIDI " ANGE APPROVED MAR 17 2009 City of Tukwila BUILDING DIVISION �U = 24" X 30" WINDOW IN BOOKS (9 TOTAL) 1)09._ 033 REOENVEp MAR 1 2000 PERMIT GENTEEL, NOTE: EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOT - CANDLE AND A MINIMUM AT ANY POINT OF 0.1 FOOT - CANDLE MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITED TO DECLINE TO 0b FOOT- CANDLE AVERAGE AND A MINIMUM AT ANY POINT OF 006 FOOT- CANDLE AT THE END OF THE EMERGANCY L4HTING TIME DURATION. A MAXIMUM -TO- MINIMUM ILLUMINATJQN UNIFORMITY RATIO OF 40 TO I SHALL NOT SE EX EDED. U W 0 Co e m w ft` } 0 te a 0 9 0 a CO CO N N co w W Iw X co W O I V) O) ILI% P U O z a W � a z E-4 H cn U O 0 z O g ,L25 H F—I z T= 1 Z: \CAD \2009 \0902 LINDAL- BROADSTRIPE BLDG B \CD'S \T- 1,T- 2,T- 3.DWG, 3/1 ?/2009 10:50:08 AM, DesigNet 500 MAIN.pc3 z .....-„,„_........_..-- ...., _. ' PROJECT 08113 DRAWN BY KEWLE 60-60- ZO IWO CHECKED BY DAVID ava DESCRIPTION N3::1 A3Zi SUBMIT FOR PERMIT AND TO CONTRACTOR 31-VO I so INAS EE LEGEND s v v I EXIT >.< U OOD TRIM 2 1/2" RADIUS EDGES EXISTING DOOR ® EXHAUST FAN OO J -BOX FOR POWER AND /OR PHONE E EXISTING N NEW DEDICATED $ SWITCH BLOCK e GRID FOAM TAPE e WALL ATTACH BOTTOM TRACK TO CONC. FLOOR W/ POWDER DRIVEN HILTI ANCHORS AT 24" O.C. 2 V2" RUBBER BASE a CARPET WALL SECTION SCALE: 1 -V2" = P_0" CORK VERT SURFACE PLAS. LAM BRACE OVER PLYWOOD 5' - O.C. COUNT-DETAIL SCALE: 1 -1/2 : 1' -0' EXISTING WALL NEW STEEL STUD WALL TO UNDERSIDE OF CEILING W/ SOUND INSULATION EXISTING WALL TO BE REMOVED. NEW DOOR FOUR -FLEX OUTLET DUPLEX OUTLET WALL TELEPHONE OUTLET AND DATA, MUDRING, CONDUIT AND PULL STRING ONLY. ILLUMINATED EXIT SIGN W/ PATHWAY LIGHTING 4 BATTERY BACKUP EX. RECESSED 2X4 -3 TUBE FLUORESCENT 88 WATT LIGHT FIXTURE EX. RECESSED 2X4 -3 TUBE FLUORESCENT 88 WATT TO BE REMOVED AND OR RELOCATED LIGHT FIXTURE EX. RECESSED 2X4 -3 TUBE FLUORESCENT 88 WATT RELOCATED LIGHT FIXTURE 22" WIDE SOUND BATTS EA. SIDE WALL e SOUND WALL 1 lI•UI1UIIUU■UI■■•F" r■iiiuuuu•ui IWO ►ice PLAS. LAM OVER PLYWOOD 2' -6" PLAS. LAM OVER PLYWOOD OVER 2X4 FRAMING FOR WALLS GREATER THAN 8'- 0" IN WIDTH WITHOUT AN INTERSECTING WALL, PROVIDE I2ga. WIRES SPLAYED e 45' TO AN EYE SCREW a ROOF AND TOP OF WALL CONT. METAL TRIM. 5/8" GYP. BD. ACOUSTICAL BLANKET 9 ALL WALLS CAULK GYP. BD. TO FLOOR e ALL SOUND AND INSUL. WALLS ,_ SECTION PLAS. LAM OVER PLYWOOD 2X6 STUDS PLAS. LAM OVER PLYUJOOD PROVIDE POWER AND PHONE AT 4 PLACES UJ/ COUNTER CUT OUTS ABOVE ANCHOR 2X TO FLOOR U I 1 - 2 - aiiilorA A II 1 k 0 o� 50' J -BOX FOR POWER, \ PHONE AND DATA FOR \ 4 WORKSTATIONS, 3 PLACES NORTH SCALE: 1/8" = 1' -0" NOTE: REMOVE 11 EXISTING LIGHTS AND RELOCATE THE SAME 11 LIGHTS SO NO CHANGE IN WATTAGE (EXEMPT) 44 -gill D C 1 &' -Vih1 NG 1' 1 CL C a � N REVILED OF R CODE COMPLIANCE APPROVE MAR 17 2009 City of Tukwila BUILDING DIVISION AN 109-0 RECEIVED MAR -112009 PERMIT CENTER 0 w z 0 P.4 W a w E ^ H V 1 U 0 z xi 2 Z: \CAD \2009 \0902 LINDAL- BROADSTRIPE BLDG B \CD'S \T- 1,T- 2,T- 3.DWG, 3/10/2009 10:53:09 AM, DesigNet 500 MAIN.pc3 AS HINGTON