HomeMy WebLinkAboutPermit D09-038 - CITY OF TUKWILA - STARFIRE SPORTS - INFILL WALL AND DOORSSTARFIRE SPORTS
14800 STARFIRE WAY
D09 -038
Parcel No.: 2323049001
Address: 14800 STARFIRE WY TUKW
Suite No:
Tenant:
Name: STARFIRE SPORTS
Address: 14800 STARFIRE WY , TUKWILA WA
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Owner:
Name: TUKWILA CITY OF
Address: 6200 SOUTHCENTER BLVD , TUKWILA WA 98188
Phone:
Contact Person:
Name: JULIE HOYLE LOWE
Address: 14800 STARFIRE WY , TUKWILA WA 98188
Phone: 206 431 -3232
Contractor:
Name: DUCHESS CONSTRUCTION INC
Address: 15875 FOREST CANYON RD E , SUMNER WA 98390
Phone: 253 891 -2016
Contractor License No: DUCHECI038NJ
DESCRIPTION OF WORK:
REMOVE EXISTING OVERHEAD INTERIOR DOORS, REPLACE WITH INFILL WALL AND DOUBLE DOORS
Value of Construction:
Type of Fire Protection:
Type of Construction:
doc: IBC -10/06
Citylif Tukwila •
$3,000.00
DEVELOPMENT PERMIT
* *continued on next page **
Permit Number: D09 -038
Issue Date: 04/03/2009
Permit Expires On: 09/30/2009
Expiration Date: 09/13/2009
Fees Collected: $232.53
International Building Code Edition: 2006
Occupancy per IBC:
D09 -038 Printed: 04 -03 -2009
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Permit Center Authorized Signature:
doc: IBC -10/06
City Tukwila 0
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
N
N
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
Start Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
uj-,1L'LL
Print Name: t'W
Permit Number: D09 - 038
Issue Date: 04/03/2009
Permit Expires On: 09/30/2009
Date:
End Time:
Fill 0 c.y.
End Time:
4-3-09
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this per • • • •t presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction o • , ance of ork. I am uthorized to sign and obtain this development permit.
Signature: )_ Date:,3 - () /
This permit shall become null and void if the w is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
D09 -038 Printed: 04 -03 -2009
Parcel No.: 2323049001
Address:
Suite No:
Tenant:
14800 STARFIRE WY TUKW
STARFIRE SPORTS
1: ** *BUILDING DEPARTMENT CONDITIONS * **
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
D09 -038
ISSUED
03/13/2009
04/03/2009
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design
requirements of ASCE 7.
6: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
7: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
11: ** *FIRE DEPARTMENT CONDITIONS * **
12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
13: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at
one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the all purpose" (2A, 10 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
doc: Cond -10/06
D09 -038 Printed: 04 -03 -2009
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
15: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
17: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4 -4)
18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
22: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress
travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access
corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the
nearest visible exit sign. (IFC 1011.1)
23: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with
the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having
a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be
less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire
Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high
contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not
energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction
cannot be readily changed. (IFC 1011.5.1)
24: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system
provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3)
25: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means
of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the
floor level. The power supply for the means of egress illumination shall normally be provided by the premise's
electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less
than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2,
1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished.
doc: Cond -10/06
D09 -038 Printed: 04 -03 -2009
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
26: Aisles leading to required exits shall be provided from all portions of the building and the required width of the
aisles shall be unobstructed. (IFC 1013.4)
27: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinkler heads. (IFC 901.4)
28: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
29: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
30: Local U.L. central station supervision is required. (City Ordinance #2051)
31: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require
relocation and/or addition of audible /visual notification devices. (City Ordinance #2051)
32: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
33: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
34: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70)
35: New and existing buildings shall have approved address numbers, building numbers or approved building identification
placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers
shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a
minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1)
36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
37: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
38: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed
description of intended use.
39: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
40: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Cond -10/06
* *continued on next page **
D09 -038 Printed: 04 -03 -2009
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
doc: Cond -10/06
Print Name: ( 1 �1(� F1 \, _ — Co Li
Date: ( - 1 ' - 3 - - /1
D09 -038 Printed: 04 -03 -2009
CITY OF TUKWIL
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tulcwila.wa.us
Building Permit No. P01 t -
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.: 232 -304 9 O /
Site Address: 14/30 S e- \N A4j Suite Number:
Tenant Name: I i t2a 6R:1'0
Property Owners Name: 31 -i i2 Spo — �' A ,
Mailing Address: 1 4 c) c3121/2-12-Ft ria W 4`( � Tv , jA14 'T81
E -Mail Address: 153oo N E 19 (ea Q A OL -CNA
Company Name: V V WOW..
Mailing Address: t F.501
`,, 4E M COVE-
Contact Person: )At\1' 11V p.-
E -Mail Address: PAN4 iDA N 4 w E e'1- (? . C 3
City
New Tenant:
Floor: V PPee
❑ Yes ..No
State Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: 0 ()Lie iict ,E Low E 1 , ' Day Telephone: Coo) 431 -3 2-
Mailing Address: 14800 379509-A9 12E W ��V J LA A 96188
JULIE @S r1-t 12CSpoeTS - Fax (2,t ) State
31 11 Zip
E -Mail Address: F Number:
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: Do Criess ao,i, 'j1a c ot
Mailing Address: 31((i OZ tt DD > � f \IE p, WZ N 1,v A o 9'
city state Zip
Contact Person: 1 IJ E Day Telephone: L25 - 57 8
Fax Number: CZ 3) - 731 - S321
Contractor Registration Number: Expiration Date:
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
a,l.� r e L L w>q 98)1a
State C Zip
Day Telephone: () ' 7 I �— 4651
Fax Number: t 79 S Z 2 8
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name: N /4-
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
H:\Applications\Fonns- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFOROTION - 206 -431 -3670
•
Valuation of Project (contractor's bid price): $ 3, GX.O -� Existing Building Valuation: $
F-
Scope of Work (please provide detailed information): eI(O"J I$P t'.) OV E 2 H' I r\li DcoeS, I PL4ce W/ i NFt LL V44-U- AND DouaLe- .L oc 2S_
Will there be new rack storage? ❑ Yes. No
Provide All Building Areas in Square Footage Below
E P17 Rrrl 1T D08 3
If yes, a separate permit and plan submittal will be required.
PLANNING DIVISION: SM P ]-' 4 1) c - 34B
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Will there be a change in use? ❑ Yes le No If `yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Compact: Handicap:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If 'yes', attach list of materials and storage locations on a separate 8 -1/2 " x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM e pi ar $} Do- 34.3
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
SG pe / t 4! )%m8 - 43
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1u Floor
r Floor
3 Floor
Floors thru
Basement
Accessory Structure'
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
BUILDING PERMIT INFOROTION - 206 -431 -3670
•
Valuation of Project (contractor's bid price): $ 3, GX.O -� Existing Building Valuation: $
F-
Scope of Work (please provide detailed information): eI(O"J I$P t'.) OV E 2 H' I r\li DcoeS, I PL4ce W/ i NFt LL V44-U- AND DouaLe- .L oc 2S_
Will there be new rack storage? ❑ Yes. No
Provide All Building Areas in Square Footage Below
E P17 Rrrl 1T D08 3
If yes, a separate permit and plan submittal will be required.
PLANNING DIVISION: SM P ]-' 4 1) c - 34B
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Will there be a change in use? ❑ Yes le No If `yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Compact: Handicap:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If 'yes', attach list of materials and storage locations on a separate 8 -1/2 " x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM e pi ar $} Do- 34.3
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
SG pe / t 4! )%m8 - 43
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 0
Signature:
•
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
Date Application Accepted:
Print Name: �1� � � �t +� L L ew Day Telephone: ( 2 B1 - 3232
Mailing Address: 14 pycoe 31A-12A 120 WA."(
H:Wpplications\Forms-Applications On Lme\2009 Applications \1 -2009 - Petmit Application.doc
Revised: 1 -2009
bh
1
1 Date Application Expires:
Date: 3 - 09'
TUKv� W 98)88
City State Zip
Staff Initials:
Page 6 of 6
Parcel No.: 2323049001 Permit Number: D09 -038
Address: 14800 STARFIRE WY TUKW Status: PENDING
Suite No: Applied Date: 03/13/2009
Applicant: STARFIRE SPORTS Issue Date:
Receipt No.: R09 -00406
Initials:
User ID:
Payee:
doc: Receipt -06
JEM
1165
ACCOUNT ITEM LIST:
Description
STARFIRE SPORTS
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 11046 232.53
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
Account Code Current Pmts
000/322.100
000/345.830
640.237.114
RECEIPT
Total: $232.53
•
Payment Amount: $232.53
Payment Date: 03/13/2009 02:47 PM
Balance: $0.00
138.20
89.83
4.50
Printed: 03 -13 -2009
Project:
St Aide S( *S
Type of Inspection:
1 - I t..J A (._
Address:
I E500 Si I (.&
Date Called:
1
Special Instructions:
Date Wanted:
`S' - 1
3 - CA
p.m.
Requester:
Phone No:
INSPECTION RECORD
3 Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
PERMIT NO.
N Approved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
ra 5 - 0 206
spect
P
Date:
1
.0 REINSPECTION FE EQUIREI. Prior to inspection, fee must be
d t 6300 Southcenter Bl d., Suite 100. Call to schedule reinspection.
Receiiy lo.: 'Date:
Project:
S, CPo QTS
Type of Inspection:
SulsPoki el Oell_i
Address:
1 I-1 GOO s r A lZ. CI (Z- E (A
Date Called:
Special Instructions:
Date Wanted:
a.m.
Requester:
Phone No:
.2 0( 'iu(0 6 3SU
I PECTION RECORD
l Retain a copy with permit
INSP CTION NO. •
6300 Southcenter Blvd., #100, Tukwila, WA 98188
bt t
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 1
(206)431 -3670
oved per applicable codes. Corrections required prior to approval.
COMMENTS:
15
Inspecto
.00 REINSPECTION EE RE UIRED. Prior to inspection, fee mu t be
d at 6300 Southcenter Blvd., uite 100. Call to schedule reinsp ction.
Re pt No.:
Date .4..
Date:
Project: l �f
�7i�4� � � .,���
/ �
Type of Ins ection \ 1
4-4 ".. / .—) n J
dress
/ 5/Q 40 —.S
_
4
?il
Date Called:
/-
Special Instructions:
f
Date Wanted:
Z/ S °
a n.
U J'
Requester:
Phone No
a‘ ` V
— 6&_<.
INSPECTION RECORD
copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3
�,a..a
INSPEt'�t6 O
❑
L)4 4"
Approved per applicable codes. Corrections required prior to approval. `p
COM TS
! Spector:
I Rec i . No.:
INSPECTION FEE ' QUI ° ED. Prior to inspection, fee must be
300 Southcenter Blvd. Suite 100. Call to schedule reinspection.
1
Project:
ST e02F st�iti�,
Type of Inspection:
i RAmINJG
Address:
I`-I 8 S1 rA Qti l(r>
L1/4)9
Date Called:
Special Instructions:
Date Wanted: Ca,
L4 - 7- 0 5 p.m.
Requester:
Phone No:
2.0(0 GS" V
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
R-
(206)431 -3
El Corrections required prior to approval.
COMMENTS:
T.v `/ z✓A/ /
Inspector:
Date:
REINSPECTION FEE R UIRED rior to inspection, fe must be
at 6300 Southcenter Blvd., , uite 100. Call to schedule reinspection.
R: eipt No.: 'Date:
Project:, S 4 P112-t.. 6pottY 5
Sprinklers:
Type of Inspection:
t'Jt rt -- YL Yv.111 -L.��
•
Address: ii-l'
Suite #:
nl -a i 2c khati
Permits:
Contact Person:
$tu OLNEA\
Special Instructions:
;,
Phone No.:
20(0 - LA46- (Q
0
Needs Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor: _ 1 , ii , k ,,
Pre-Fire:
Permits:
Occupancy Type:
INSPECTION NUMBER
CITY OF TUKWILA FIRE DEPARTMENT
Approved per applicable codes.
Word /Inspection Record Form.Doc 1/13/06
INSPECTION RECORD
Retain a copy with permit
tkr- .
• : di
PERMIT NUMBERS i
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
Corrections required prior to approval:
COMMENTS:
T IAA kg LY — o K
S pr�ti r - b t= - LoCA-cE
A ; • o g, (Lid, t� ..... .
chs At, — O_
Date: S ! 2 /01
I .
Hrs.:
Inspector: W l
E : $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
T.F.D. Form F.P. 113
•
A
P.
•
•
Dana L. Webber
Architect
City of Tukwila- Building Department
Dave Larson- Sr. Plans Examiner
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
March 23, 2009
Re: Correction Letter #1
Development Permit Application # D09 -038
Starfire Sports -14800 Starflre Way
The responses to your Correction letter are incorporated into the plans as Revision #1 "Building
Department Corrections dated 3/23/09. Responses below:
°1. As an A occupancy, two exits are required from this space. Per section 1008.1.9 IBC, the hardware needs to be
panic hardware or fire exit hardware. Please add hardware to plan.
Revised plan indicates two exits are provided. One exit is existing with existing
panic hardware and exit sign. The second exit is indicated as the set of double doors
indicated as #205 -A. This set of doors will be provided with panic hardware with an exit
II sign posted above the doors.
T. Emergency lighting is required in this space. Please show emergency lighting on plan. The systems hall meet the
requirements of sectioin 1006.4 IBC for system performance.'
Emergency lighting is shown on the revised plan.
°3. Show exit signage.'
Exit signage is shown on revised plan.
'4. An occupant load sign will need to be posted for 88 occupants. If one already exists or oneis needed, please show location on
floor plan.'
Occupant load sign location is shown on revised plan.
°5. Is this a change of use? The existing garage doors would not have qualified as exit doors and this space would
have had one exit. °
The space is existing, non - conforming. There is no change -of -use. The original
permit for the building indicated the use as a banquet room space. The scope of work
conforms to code requirements.
Sincerely,
Dana Webber, Principal -
Dana Webber Architect
Studio:
9809 NE Murden Cove Drive Bainbridge Island, WA 98110 (206) 715 -4551 voice (206) 780-8228 fax dana@danawebber.com
1
March 17, 2009
Julie Hoyle Lowe
14800 Starfire Way
Tukwila, WA 98188
Dear Ms. Hoyle Lowe,
Bill Rambo
Permit Technician
Enclosures
File: D09 -038
•
City of Tukwila
•
Jim Haggerton, Mayor
Department of Community Development jack Pace, Director
RE: Letter of Incomplete Application # 1
Development Permit Application D09 -038
Starfire Sports — 14800 Starfire Way
This letter is to inform you that your permit application received at the City of Tukwila Permit Center on
March 13, 2009 is determined to be incomplete. Before your application can continue the plan review
process the following items from the following department need to be addressed:
Building Department: Dave Larson at 206 431 -3678 if you have any questions concerning the
following comments.
Please address the comment above in an itemized format with applicable revised plans, specifications,
and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or
other documentation be resubmitted with the appropriate revision block.
In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not
be accepted through the mail or by a messenger service.
If you have any questions, please contact me at the Permit Center at (206) 431 -3670.
Sincerely,
C:111J
P:\Permit Cen ter \Incomplete Letters\2009 \D09 -038 Incomplete Ltr #I.DOC
wer
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665
•
Determination of Completeness Memo
Date: March 17, 2009
Project Name: Starfire Sports
Permit #: D09 -038
Plan Review: Dave Larson, Senior Plans Examiner
•
Tukwila Building Division
Dave Larson, Senior Plan Examiner
The Building Division has deemed the subject permit application incomplete. To assist the applicant in
expediting the Department plan review process, please forward the following comments.
(GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size).
(If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped,
not copied.)
1. As an A occupancy, two exits are required from this space. Per section 1008.1.9 IBC, the door
hardware needs to be panic hardware or fire exit hardware. Please add hardware to plan.
2. Emergency lighting is required in this space. Please show emergency lighting on plan. The system
shall meet the requirements of section 1006.4 IBC for system performance.
3. Show exit signage
4. An occupant load sign will need to be posted for 88 occupants. If one already exists or one is
needed, please show location on floor plan.
5. Is this a change of use? The existing garage doors would not have qualified as exit doors and this
space would have had one exit.
Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670.
No further comments at this time.
ACTIVITY NUMBER: D09 -038 DATE: 03 -25 -09
PROJECT NAME: STARFIRE SPORTS
SITE ADDRESS: 14800 STARFIRE WY
Original Plan Submittal
Response to Correction Letter #
X Response to Incomplete Letter # 1
Revision # After Permit Issued
DEPARTMENTS:
17L /V(/ 1/101k
Building Division
Public Works
Complete
Comments:
APPROVALS OR CORRECTIONS:
Documents/routing slip.doc
2 -28 -02
HERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Fire Prevention
❑ Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES /THURS R TING:
Please Route Structural Review Required No further Review Required ❑
REVIEWER'S INITIALS:
DATE:
�M AP 3)
Planning Division
Permit Coordinator
DUE DATE: 03-26-09
Not Applicable
DUE DATE: 04 -23-09
Approved I Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
OPERNl1T COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D09 -038 DATE: 03 -13 -09
PROJECT NAME: STARFIRE SPORTS
SITE ADDRESS: 14800 STARFIRE WY
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS: 3_cZ�oq
bL. d'ev4. 1
Building Division
GliV
Public Wor s
Comments:
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete ❑
APPROVALS OR CORRECTIONS:
Documents/routing slip.doc
2 -28 -02
AAA Mvc 1-ti--0/
Fire Prevention
Structural
Incomplete
TUES /THURS ROUTING:
Please Route ❑ Structural Review Required ❑
REVIEWER'S INITIALS:
Planning Division
Permit Coordinator
U
DUE DATE: 03-17-09
Permit Center Use Only
INCOMPLETE LETTER MAILED: 1„4-7-0q
Departments determined incomplete: Bldg Fire ❑
LETTER OF COMPLETENESS MAILED:
Ping ❑ PW ❑ Staff Initials:
rv4
No further Review Required
DATE:
Not Applicable
DUE DATE: 04-14-09
Approved ❑ Approved with Conditions I Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
REVISION SVJB1VIITTAL
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: '?)/03 Z33 A Plan Check/Permit Number: D09-038
Response to Incomplete Letter # 1
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206- 431 -3665
Web site: http: //www.ci.tukwila.wa.us
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: STARFIRE SPORTS
Project Address: 14800 Starfire Way
Contact Person: <IVU E [ ulb - 1....r: We Phone Number: (Zo) 431-323 2
Summary of Revision: s ee. ire frl vi
� � � ! • I r N. C LU W 1- St(, IJ + 'PANIC
"�Me4QEC1 L rc & Ns F644.1
kG N E & - oavJ 0 1.1
o DC-COPT- LoA-3 8L6n1 DNI P
\applications\forms- applications on line\revision submittal
Created: 8 -13 -2004
Revised:
Steven M. Mullet, Mayor
Steve Lancaster, Director
ciTigt LA
MAR p 51009
PERMIT CENTER
J
Sheet Number(s): /) .-O - I hslOr4 4 -1 DA-1
E
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
Entered in Permits Plus on o'
Name
Role
Effective Date
Expiration Date
BOONE, BROOK
PRESIDENT
09/25/2001
Bond
Amount
LEENSTRA, RUTH
TREASURER
01/01/1980
SE5602
LEENSTRA, HANK
VICE PRESIDENT
09/25/2001
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
4
CBIC
SE5602
08/07/2002
Until
Cancelled
$12,000.00
08/14/2002
3
CUMBERLAND
CAS Et
SURETY CO
MB31841
08/07/2001
Until
Cancelled
08/14/2002
$12,000.0007/25
/2001
2
CUMBERLAND
CAS Et
SURETY CO
MB31841
08/07/2000
08/07/2001
$6,000.00
UNITED
Untitled Page
•
•
General /Specialty Contractor
A business registered as a construction contractor with LEtI to perform construction work
within the scope of its specialty. A General or Specialty construction Contractor must
maintain a surety bond or assignment of account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent
Company
DUCHESS CONSTRUCTION
INC
2538912016
15875 FOREST CANYON
RD E
SUMNER
WA
98390
PIERCE
Corporation
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Previous License
Next License
Associated
License
Specialty 1
Specialty 2
601805583
ACTIVE
DUCHECI038NJ
CONSTRUCTION
CONTRACTOR
8/11/1997
9/13/2009
DUCHEH1935QH
GENERAL
UNUSED
Business Owner Information
Bond Information
https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= DUCHECI038NJ
Page 1 of 2
04/03/2009
OCCUPANCY SIGNAGE
"MAXIMUM NUMBER OF
OCCUPANTS 88 PERSONS"
PROVIDE WALL- MOUNTED
EXIT SIGN ABOVE DOOR.
DOOR #205 -A ONLY.
1/
EXISTING HALLWAY
1 201
0
CV
SEE EXIT1
NOTE #1
RTIAL FLOOR PLAN
=
6' -0"
BANQUET ROOM
1205
1,310 SF / 15 SF per OCCUPANT
ASSEMBLY SPACE
88 OCCUPANTS
PARTIAL LIGHTING PLAN
1/8" =
EXISTING GARAGE DOORS TO BE REMOVED
INFILL WITH MIL STUD FRAMING
AND 8" GWB EACH SIDE
8
0
0
E
\� EXISTING 2X2
CEILING GRID
TO REMAIN.
A -1
A -1E
SEE NOTE #1
6' -0"
2x2 FLUORESCENT FIXTURE W/
DIRECT /INDIRECT DIFFUSER -
MOUNTED IN ACOUSTIC CEILING
GRID- PROVIDE ONE- HOUR �
RATED FIXTURE.
2x2 FLUORESCENT FIXTURE W/
DIRECT /INDIRECT DIFFUSER -
MOUNTED IN ACOUSTIC CEILI
GRID- PROVIDE ONE -HOU
RATED FIXTURE- WITH
EMERGENCY BATTERY BACK -UP
FIELD VERIFY ALL DIMENSIONS
FROM CENTER OF COLUMN
ON GRIDLINE 10
PLANNING APPROVED
No changes can be made. to these
plans without approval from the
Planning Division of DCD
Approved By
Date:
r
y
1
EXISTING
WATER HTR ROOM
I208I
a ;h _/- ;' . _.:F1_
UPPER LEVEL PLAN
EXIST'G EXIT W/ PANIC HW
AND EXIT SIGN.
WORK
AREA
SEPARsc, PERMIT
REQUIRED FOR:
Mechanical!
,g Electrical
tumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the s cope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
PROJECT DIRECTORY
OWNER
Project Owner:
Starfire Sports
Chris Slatt
14800 Starfire Way
Tukwila, WA 98188
(206) 431 -3232
PROJECT DATA
PROJECT DESCRIPTION
Remove existing overhead doors. Construct inf II wall and double
doors at each location.
ADDRESS OF PROPERTY
14800 Starfire Way
Tukwila, WA 98188
LEGAL DESCRIPTION
A PIN OF THE E1 /2, NE1 /4, SEC. 23, TWP. 23 N. RNG. 4E., W.M. AND THE W1/2,
NW1 /4 SEC. 24, TWP. 13N., RNG. 4 E., W.M.
TAX IDENTIFICATION NUMBER
KING COUNTY PARCEL NUMBER: 2323049001
BUILDING CODE NOTES
APPLICABLE CODES
INTERNATIONAL BUILDING CODE 2006
INTERNATIONAL MECHANICAL CODE 2006
INTERNATIONAL FIRE CODE 2006
2006 UNIFORM PLUMBING CODE
WASHINGTON STATE AMENDMENTS
2006 WASHINGTON STATE ENERGY CODE
OCCUPANCY CLASSIFICATION
A -3 ASSEMBLY OCCUPANCY
TYPE OF CONSTRUCTION
TYPE II - A / FULLY SPRINKLERED
MECHANICAL AND ELECTRICAL PLANS WILL BE SUBMITTED
SEPARATELY FOR PERMIT.
REFERENCE CITY OF TUKWILA ORIGINAL BUILDING PERMIT
#D03 -170
NOTES
1. AT EACH OPENING PROVIDE : DOUBLE- 3' -0" X 7' -0"
HOLLOW METAL DOORS W/ 24" X 64" FULL -VIEW
pi4RF E- D'G.ASM.1/-I O i l I M TA FRAMES.
2. PROVIDE PANIC HARDWARE AT DOOR #205 -A.
VICINITY
ARCHITECT
Dana Webber Architect
9809 NE Murden Cove Dr.
Bainbridge Island, WA 98110
Phone: 206.715.4551
Fax: 206.780.8228
FIRE RESISTANCE RATING FOR BUILDING ELEMENTS
STRUCTURAL FRAME - 1 HOUR
BEARING WALLS- INT/EXT- 1 HOUR
NON - BEARING WALLS- INT /EXT- NOT RATED
FLOOR CONSTRUCTION -1 HOUR
ROOF CONSTRUCTION- 1 HOUR
INTERIOR WALL AND CEILING FINISH REQMTS
VERTICAL EXITS AND PASSAGEWAYS - CLASS B
EXIT ACCESS CORRIDORS AND OTHER EXITWAYS- CLASS B
ROOMS AND ENCLOSED SPACES - CLASS C
FILE COPY
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 0 2 2009
City o kwila
BUILDIN iv ism
M
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved P' Popy.and conditions is acknowledged°
City Of Tukwila
ILDIN DivY_ 0
INCOMPLETE
DANA L. WEBBER
ARCHITECT
BAINBRIDGE ARCHITECTS
C O L L A 8 C1 R A T I V
98 09 NE MURDEN COVE DRIVE
BAINBRIDGE ISLAND, WA 98110
(206) 71 5-4551 VOICE
(206) 780-8228 FAX
Starfi re
Banquet Room
Starfire Sports
Complex
Tukwiila , WA
CONSTRUCTION SET
If this drawing is not 22" x 34 ", it is a reduced print, scale
accordingly.
REVISIONS
NO.
DRAWN BY
dw
Bldg Dept Corr. March 23, 2009
9
GISTERED
ARCHITECT
a L. Webber
TATE OF WASHINGTON
SHEET TITLE
FLOOR PLAN
AND NOTES
PROJECT NUMBER
0905
SCALE
1/4"=1'0"
DATE A 1
March 12, 2009
DESCRIPTION
E'
RECEIVED
CITY OF TUKWILA
MAR 2 5 2009
PERMIT CENTER
CHECKED BY
dw
SHEET NUMBER
. 01
All rights reserved. Material may not be reproduced . in any form
without permission from Bainbridge Architects Collaborative.
DATE