HomeMy WebLinkAboutPermit D09-042 - FRANCISCO RESIDENCE - WHEELCHAIR RAMPFRANCISCO RESIDENCE
13856 37 AVE S
D09.042
Parcel No.: 8864000785
Address: 13856 37 AV S TUKW
Suite No:
Tenant:
Name: FRANCISCO RESIDENCE
Address: 13856 37 AV S , TUKVVILA WA
Cityiof Tukwila
Owner:
Name: LAPINE GARY +DIANA
Address: 14443 58TH AVE S , TUKWILA WA 98168
Phone:
Contact Person:
Name: DAWN FRANCISO
Address: 13856 37 AV S , TUKVVILA WA 98168
Phone: 425 221 -5416
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
DEVELOPMENT PERMIT
Contractor:
Name: OWNER AFFIDAVIT - BRIAN SEITZ FOR JOHN L SCOTT
Address: ON BEHALF OF OWNER GARY LAPINE ,
Phone:
Contractor License No:
DESCRIPTION OF WORK:
CONSTRUCTION OF A FREESTANDING WHEELCHAIR RAMP
doc: IBC -10/06
* * continued on next page **
Permit Number: D09 -042
Issue Date: 04/24/2009
Permit Expires On: 10/21/2009
Expiration Date:
Value of Construction: $750.00 Fees Collected: $76.50
Type of Fire Protection: International Building Code Edition: 2006
Type of Construction: VB Occupancy per IBC: 0022
D09 -042 Printed: 04 -24 -2009
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Permit Center Authorized Signature:
I hereby certify that I have read and :- ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit.
Signature!
Print Name:
doc: IBC-10/06
City eliTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
N
Private:
Profit: N
Private:
Date:
Permit Number: D09 -042
Issue Date: 04/24/2009
Permit Expires On: 10/21/2009
Public:
Non - Profit: N
Public:
Date: 04 !A
( (-2y-07
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
D09 -042 Printed: 04 -24 -2009
Parcel No.: 8864000785
Address:
Suite No:
Tenant:
13856 37 AV S TUKW
1: ** *BUILDING DEPARTMENT CONDITIONS * **
doc: Cond -10/06
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
FRANCISCO RESIDENCE
5: All wood to remain in placed concrete shall be treated wood.
PERMIT CONDITIONS
* *continued on next page **
Permit Number:
Status:
Applied Date:
Issue Date:
D09 -042
ISSUED
03/24/2009
04/24/2009
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 - 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
D09 -042 Printed: 04 -24 -2009
Signature:
Print Name:
doc: Cond -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
•
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
*_" - __ " k•-•--- ) Date: ("/' Z y -07
D09 -042 Printed: 04 -24 -2009
i 0 1 4 1 .
Address L 3 (, 3 7 '4U . SO
Description of work UJ he e ( C h A r Ik. v ✓✓\ 2
EE_ TT ✓ C. t-1-e 0-1
Related reference number
Project name Dom)r- FR,N3Q IG
Building
TBD36/96 -form 12
• •
City Of Tukwila
Permit Center
6300 Southcenter Boulevard, Suite, 100
Tukwila, WA 98188
(206 431 -3670)
Application #
ALTERNATE PLAN SUBMITTAL AUTHORIZATION
FOR LIMITED SCOPE OF WORK
I.B.C.& I.R.C. Section 104.1
The above project permit applicant, due to the limited scope of work is authorized to submit reduced
plan requirements described below.
1. Complete permit application required: (Note, all application must include; 1) property assessor
number, 2) copy of contractors license or completed owner waiver form.)
Mechanical Other
2. Minimum plan and /or specification requirement:
Site plan Floor plan Elevations Foundation
Cross sections Roof plan W.S.E.C. Compliance Narrative
Structural calculations (stamped by Washington State licensed engineer )
Specific required information P r 0 -
3. Other special instructions: r Z A WA k r\ ( O n{ 0 Ft I NI Vi l
Authorization b ,, �,� _ _ _ , Date 3 7-
(Authorization void 30 days after the date issued.)
ON
Parcel No.: 8864000785
Address: 13856 37 AV S TUKW
Suite No:
Applicant: FRANCISO RESIDENCE
Receipt No.: R09 -00469
Initials: JEM
User ID: 1165
Payee: DAWN M FRANCISCO
ACCOUNT ITEM LIST:
Description
doc: Receiot -06
BUILDING - NONRES
STATE BUILDING SURCHARGE
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 3839 76.50
Account Code Current Pmts
000/322.100
640.237.114
RECEIPT
Total: $76.50
Permit Number: D09 -042
Status: PENDING
Applied Date: 03/24/2009
Issue Date:
Payment Amount: $76.50
Payment Date: 03/24/2009 02:00 PM
Balance: $0.00
72.00
4.50
PAYMENT
RECEIVED
Printed: 03 -24 -2009
Project:
F424,J0 /� °
O a,,
Type of Inspection:
,iAJ4
Address:
/3 6563 7 /7u
Date Called:
Special Instructions:
Date Wanted:
3C) - 05
�m
p.m.
Requester:
Phone No:
„20 6-2- 1 )6 - /5 /
0
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
665-0g z
PERMIT NO.
(206)431 -3670
h[I Approved per applicable codes. 0 Corrections required prior to approval.•
COMMENTS:
�J
FT24ym rIll( — PPQek�,
C 2D Tor, i; a4- k-142/1":-
.00 REINSPECTION FEE REQJIRED. 1fior to inspection, fee must be
id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
R- No.: Date:
SUBJECT TO
INSPECTION
escape and rescue openings shall open directly into a public
way, or to a yard or court that opens to a public way.
Exception: Basements used only to house mechanical
equipment and not exceeding total floor area of 200 square
feet (18.58 m
R310.1.1 Minimum opening area. All emergency escape
and rescue openings shall have a minimum net clear open-
ing of 5.7 square feet (0.530 m
Exception: Grade floor openings shall have a minimum
net clear opening of 5 square feet (0.465 m
R310.1.2 Minimum opening height. The minimum net
clear opening height shall be 24 inches (610 mm).
R310.1.3 Minimum opening width. The minimum net
clear opening width shall be 20 inches (508 mm)
R310.1.4 Operational constraints. Emergency escape and
rescue openings shall be operational from the inside of the
room without the use of keys, tools or special knowledge.
R310.2 Window wells. The minimum horizontal area of the
window well shall be 9 square feet (0.9 m with a minimum
horizontal projection and width of 36 inches (914 mm). The
area of the window well shall allow the emergency escape and
rescue opening to be fully opened.
Exception: The ladder or steps required by Section R310.2.1
shall be permitted to encroach a maximum of 6 inches (152
mm) into the required dimensions of the window well.
R310.2.1 Ladder and steps. Window wells with a vertical
depth greater than 44 inches (1118 mm) shall be equipped
with a permanently affixed ladder or steps usable with the
window in the fully open position. Ladders or steps required
by this section shall not be required to comply with Sections
8311.5 and R311.6. Ladders or rungs shall have an inside
width of at least 12 inches (305 mm), shall project at least 3
inches (76 mm) from the wall and shall be spaced not more
than 18 inches (457 mm) on center vertically for the full
height of the window well.
R310.3 Bulkhead enclosures. Bulkhead enclosures shall pro-
vide direct access to the basement. The bulkhead enclosure with
the door panels in the fully open position shall provide the mini-
mum net clear opening required by Section R310.1.1. Bulkhead
enclosures shall also comply with Section R311.5.8.2.
R310.4 Bars, grilles, covers and screens. Bars, grilles, cov-
ers, screens or similar devices are permitted to be placed over
emergency escape and rescue openings, bulkhead enclosures,
or window wells that serve such openings, provided the mini-
mum net clear opening size complies with Sections R310.1.1
to R310.1.3, and such devices shall be releasable or removable
from the inside without the use of a key, tool, special knowl-
edge or force greater than that which is required for normal
operation of the escape and rescue opening.
R310.5 Emergency escape windows under decks and
porches. Emergency escape windows are allowed to be
installed under decks and porches provided the location of the
deck allows the emergency escape window to be fully opened
and provides a path not less than 36 inches (914 mm) in height
to a yard or court.
SECTION R311
MEANS OF EGRE
R311.1 General. Stairways, ramps, ext
hallways and doors shall comply with
R311.2 Construction.
BUILDING PLANNING
REVIEWED FOR
CODE COMPLIANC
APPROVED
S � ^ 2009
or egrelgal�n` es,
s section .
pity of Tukwil
kartVls101
R311.2.1 Attachment. Required ext
exterior exit stairways and simil
components shall be positively anchored to e primary
structure to resist both vertical and lateral forces. Such
attachment shall not be accomplished by use of toenails or
nails subject to withdrawal.
R.311.2.2 Under stair protection. Enclosed accessible space
under stairs shall have walls, under stair surface and any sof-
fits protected on the enclosed side with' / -inch (13 mm) gyp-
sum board.
R311.3 Hallways. The minimum width of a hallway shall be
not less than 3 feet (914 mm).
R311.4 Doors.
R311.4.1 Exit door required. Not less than one exit door
conforming to this section shall be provided for each dwell-
ing unit. The required exit door shall provide for direct
access from the habitable portions of the dwelling to the
exterior without requiring travel through a garage. Access to
habitable levels not having an exit in accordance with this
section shall be by a ramp in accordance with Section
R311.6 or a stairway in accordance with Section R311.5.
R311.4.2 Door type and size. The required exit door shall
be a side - hinged door not less than 3 feet (914 mm) in width
and 6 feet 8 inches (2032 mm) in height. Other doors shall
not be required to comply with these minimum dimensions.
R311.4.3 Landings at doors. There shall be a floor or land-
ing on each side of each exterior door. The floor or landing
at the exterior door shall not be more than 1 5 inches (38
mm) lower than the top of the threshold. The landing shall
be permitted to have a slope not to exceed 0.25 unit vertical
in 12 units horizontal (2- percent).
Exceptions:
1. Where a stairway of two or fewer risers is located
on the exterior side of a door, other than the
required exit door, a landing is not required for the
exterior side of the door provided the door, other
than an exterior storm or screen door does not
swing over the stairway.
2. The exterior landing at an exterior doorway shall
not be more than 7 inches (196 mm) below the
top of the threshold, provided the door, other than
an exterior storm or screen door does not swing
over the landing.
3. The height of floors at exterior doors other than the
exit door required by Section R311.4.1 shall not be
more than 7 inches (186 mm) lower than the top
of the threshold.
The width of each landing shall not be less than the door
served. Every landing shall have a minimum dimension of
36 inches (914 mm) measured in the direction of travel.
2006 INTERNATIONAL RESIDENTIAL CODE 53
1
i
1
BUILDING PLANNING
R311.4.4 Type of lock or latch. All egress doors shall be
readily openable from the side from which egress is to be
made without the use of a key or special knowledge or effort.
R311.5 Stairways.
R311.5.1 Width. Stairways shall not be less than 36 inches
(914 mm) in clear width at all points above the permitted
handrail height and below the required headroom height.
Handrails shall not project more than 4.5 inches (114 mm)
on either side of the stairway and the minimum clear width
of the stairway at and below the handrail height, including
treads and landings, shall not be less than 31.5 inches (787
mm) where a handrail is installed on one side and 27 inches
(698 mm) where handrails are provided on both sides.
Exception: The width of spiral stairways shall be in
accordance with Section R311.5.8.
R311.5.2 Headroom. The minimum headroom in all parts
of the stairway shall not be less than 6 feet 8 inches (2036
mm) measured vertically from the sloped plane adjoining
the tread nosing or from the floor surface of the landing or
platform.
R311.5.3 Stair treads and risers.
R311.5.3.1 Riser height. The maximum riser height
shall be 7 inches (196 mm). The riser shall be mea-
sured vertically between leading edges of the adjacent
treads. The greatest riser height within any flight of stairs
shall not exceed the smallest by more than 3/8 inch (9.5
mm).
R311.5.3.2 Tread depth. The minimum tread depth
shall be 10 inches (254 mm). The tread depth shall be
measured horizontally between the vertical planes of the
foremost projection of adjacent treads and at a right
angle to the tread's leading edge. The greatest tread depth
within any flight of stairs shall not exceed the smallest by
more than 3/8 inch (9.5 mm). Winder treads shall have a
minimum tread depth of 10 inches (254 mm) measured
as above at a point 12 inches (305 mm) from the side
where the treads are narrower. Winder treads shall have a
minimum tread depth of 6 inches (152 mm) at any point.
Within any flight of stairs, the largest winder tread depth
at the 12 inch (305 mm) walk line shall not exceed the
smallest by more than 3 /8 inch (9.5 mm).
R311.5.3.3 Profile. The radius of curvature at the lead-
ing edge of the tread shall be no greater than 9 /16 inch (14
mm). A nosing not less than 3 /, inch (19 mm) but not
more than 1'/, inch (32 mm) shall be provided on stair-
ways with solid risers. The greatest nosing projection
shall not exceed the smallest nosing projection by more
than 3 /8 inch (9.5 mm) between two stories, including
the nosing at the level of floors and landings. Beveling
of nosing shall not exceed '/ inch (12.7 mm). Risers
shall be vertical or sloped from the underside of the
leading edge of the tread above at an angle not more
than 30 degrees (0.51 rad) from the vertical. Open risers
are permitted, provided that the opening between treads
does not permit the passage of a 4 -inch diameter (102
mm) sphere.
Exceptions:
1. A nosing is not required where the tread depth
is a minimum of 11 inches (279 mm).
2. The opening between adjacent treads is not lim-
ited on stairs with a total rise of 30 inches (762
mm) or less.
R311.5.4 Landings for stairways. There shall be a floor or
landing at the top and bottom of each stairway.
Exception: A floor or landing is not required at the top of
an interior flight of stairs, including stairs in an enclosed
garage, provided a door does not swing over the stairs.
A flight of stairs shall not have a vertical rise larger than
12 feet (3658 mm) between floor levels or landings.
The width of each landing shall not be less than the width
of the stairway served. Every landing shall have a minimum
dimension of 36 inches (914 mm) measured in the direction
of travel.
R311.5.5 Stairway walking surface. The walking surface
of treads and landings of stairways shall be sloped no
steeper than one unit vertical in 48 inches horizontal (2 -per-
cent slope).
R311.5.6 Handrails. Handrails shall be provided on at least
one side of each continuous run of treads or flight with four
or more risers.
R311.5.6.1 Height. Handrail height, measured verti-
cally from the sloped plane adjoining the tread nosing, or
finish surface of ramp slope, shall be not less than 34
inches (864 mm) and not more than 38 inches (965 mm).
R311.5.6.2 Continuity. Handrails for stairways shall be
continuous for the full length of the flight, from a point
directly above the top riser of the flight to a point directly
above the lowest riser of the flight. Handrail ends shall be
returned or shall terminate in newel posts or safety termi-
nals. Handrails adjacent to a wall shall have a space of not
less than 1 inch (38 mm) between the wall and the
handrails.
Exceptions:
1. Handrails shall be permitted to be interrupted
by a newel post at the turn.
2. The use of a volute, turnout, starting easing or
starting newel shall be allowed over the lowest
tread.
R311.5.6.3 Handrail grip size. All required handrails
shall be of one of the following types or provide equiva-
lent graspability.
1. Type I. Handrails with a circular cross section
shall have an outside diameter of at least 1' 4 inches
(32 mm) and not greater than 2 inches (51 mm). If
the handrail is not circular it shall have a perimeter
dimension of at least 4 inches (102 mm) and not
greater than 6'/, inches (160 mm) with a maximum
cross section of dimension of 2'/ inches(57 mm).
2. Type II. Handrails with a perimeter greater than 6'/,
inches (160 mm) shall provide a graspable finger
54 2006 INTERNATIONAL RESIDENTIAL CODE®
recess area on both sides of the profile. The finger
recess shall begin within a distance of inch (19
mm) measured vertically from the tallest portion of
the profile and achieve a depth of at least 5 / 1 6 inch (8
mm) within 7 / 8 inch (22 mm) below the widest por-
tion of the profile. This required depth shall con-
tinue for at least' / inch (10 mm) to a level that is not
less than 1 inches (45 mm) below the tallest por-
tion of the profile. The minimum width of the hand-
rail above the recess shall be 1 inches (32 mm) to
a maximum of 2 inches (70 mm). Edges shall
have a minimum radius of 0.01 inch (0.25 nun).
R311.5.7 Illumination. All stairs shall be provided with
illumination in accordance with Section R303.6.
R311.5.8 Special stairways. Spiral stairways and bulkhead
enclosure stairways shall comply with all requirements of
Section R311.5 except as specified below.
R311.5.8.1 Spiral stairways. Spiral stairways are per-
mitted, provided the minimum width shall be 26 inches
(660 mm) with each tread having a 7' / inches (190 mm)
minimum tread depth at 12 inches from the narrower
edge. All treads shall be identical, and the rise shall be no
more than 9 inches (241 mm). A minimum headroom
of 6 feet 6 inches (1982 mm) shall be provided.
R311.5.8.2 Bulkhead enclosure stairways. Stairways
serving bulkhead enclosures, not part of the required
building egress, providing access from the outside grade
level to the basement shall be exempt from the require-
ments of Sections R311.4.3 and R311.5 where the maxi-
mum height from the basement finished floor level to
grade adjacent to the stairway does not exceed 8 feet
(2438 mm), and the grade level opening to the stairway is
covered by a bulkhead enclosure with hinged doors or
other approved means.
R311.6 Ramps.
R311.6.1 Maximum slope. Ramps shall have a maximum
slope of one unit vertical in twelve units horizontal (8.3 -per-
cent slope).
Exception: Where it is technically infeasible to comply
because of site constraints, ramps may have a maximum
slope of one unit vertical in eight horizontal (12.5 percent
slope).
R311.6.2 Landings required. A minimum 3- foot -by -3 -foot
(914 mm by 914 mm) landing shall be provided:
1. At the top and bottom of ramps.
2. Where doors open onto ramps.
3. Where ramps change direction.
R311.63 Handrails required. Handrails shall be provided
on at least one side of all ramps exceeding a slope of one unit
vertical in 12 units horizontal (8.33- percent slope).
R311.6.3.1 Height. Handrail height, measured above
the finished surface of the ramp slope, shall be not less
than 34 inches (864 mm) and not more than 38 inches
(965 mm).
BUILDING PLANNING
R311.6.3.2 Handrail grip size. Handrails on ramps
shall comply with Section R311.5.6.3.
R311.6.3.3 Continuity. Handrails where required on
ramps shall be continuous for the full length of the ramp.
Handrail ends shall be returned or shall terminate in
newel posts or safety terminals. Handrails adjacent to a
wall shall have a space of not less than 1.5 inches (38
mm) between the wall and the handrails.
SECTION R312
GUARDS
R312.1 Guards. Porches, balconies, ramps or raised floor sur-
faces located more than 30 inches (762 mm) above the floor or
grade below shall have guards not less than 36 inches (914 mm)
in height. Open sides of stairs with a total rise of more than 30
inches (762 mm) above the floor or grade below shall have
guards not less than 34 inches (864 mm) in height measured
vertically from the nosing of the treads.
Porches and decks which are enclosed with insect screening
shall be equipped with guards where the walking surface is
located more than 30 inches (762 mm) above the floor or grade
below.
R312.2 Guard opening limitations. Required guards on open
sides of stairways, raised floor areas, balconies and porches
shall have intermediate rails or ornamental closures which do
not allow passage of a sphere 4 inches (102mm) or more in
diameter.
Exceptions:
1. The triangular openings formed by the riser, tread and
bottom rail of a guard at the open side of a stairway are
permitted to be of such a size that a sphere 6 inches
(152 mm) cannot pass through.
2. Openings for required guards on the sides of stair
treads shall not allow a sphere 4 inches (107 mm) to
pass through.
SECTION R313
SMOKE ALARMS
R313.1 Smoke detection and notification. All smoke alarms
shall be listed in accordance with UL 217 and installed in
accordance with the provisions of this code and the household
fire warning equipment provisions of NFPA 72.
Household fire alarm systems installed in accordance with
NFPA 72 that include smoke alarms, or a combination of
smoke detector and audible notification device installed as
required by this section for smoke alarms, shall be permitted.
The household fire alarm system shall provide the same level of
smoke detection and alarm as required by this section for
smoke alarms in the event the fire alarm panel is removed or the
system is not connected to a central station.
R313.2 Location. Smoke alarms shall be installed in the fol-
lowing locations:
1. In each sleeping room.
2006 INTERNATIONAL RESIDENTIAL CODE 55
• , . • . • •
" • -
, • •
• ..:164Nir.a•riAw.,
' .;!..-••. ‘.• ' ' ' '.- . :'; ; r: : •-•rkA:
'Pt.". ...., , i .:, " -- ""•‘-z.'.....2_ - . ...-..... . ' ',::. - ' • , • ^ ...-: it' ' .' ''''' •
• : li . . : — . ' t '',.., .' ....., , ' , ea,.. ,`:::;: ".— " - "•:',` , 4,'' ,. . •- , ' lit.,- - •
-' : '...,'• .'., • .. • 'J.; . - .. ,,- 4",, - ,' %., ... • . .. , . .
' - : - 1 . • :-',,,, ,i . , ', .,,, .
:•:. ', : — • .. • • ...; ''s.,.. .,- ' ' 9. *.,:
•
•
.41.
• , • .
- • .
•
CITY OF T UKWIL A
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (2o6) 43 - 367o FAX 431-3665
E - mail: tuk 1 n ci.tukwila.wl.us
STATE OF WASHINGTON)
COUNTY OF KING ) ss.
AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION
, states as follows:
[please print name
1. I have made application for a permit from the City of Tukwila, Washington.
2.
7 9 .0 0
PERMIT NO: P4 1
I understand that state law requires that all building construction contractors be registered with of Washington. The exceptions to this requirement are stated under Section 18.2 of the
Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have
the
read or am familiar with RCW 18.27.090,
have
3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the
City of Tukwila must verify either that the contractor is registered by the State of Washington, or that
one of the exemptions stated under RCW 18.27.090 applies.
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I
hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090,
I consider the work authorized under this permit to be exempt under number L, and will therefore
not be performed by a registered contractor.
5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to
persons making electrical installations on their own property or to regularly employed employees
working on the premises of their employer. The proposed electrical work is not for the construction
of a new building for rent, sale or lease.
I understand that I may be waiving certain rights that I might otherwise have under state law in any decision
to engage an unregistered contractor to perform construction work.
JEANNE E. SULLIVAN
NOTARY PIJBLIC
STATE OF ► ' S H)NGT0N
COMMISS& 10. r AP►f2ES
OCTO -r. 7009
Owner /Owner's Agent
Signed and sworn to before me this
° day of /4ffJ l , 20079.
3 L . .S - 44
Permit Center /Building Division
206 431 -3670
Public Works Department
206 433 - 0179
Planning Division
206 431-3670
C,
N !1'ARY PUBLIC in and for the State of Washington
Residing at / -1 " 1 - , County
C/e &slnt t SI) / /s'1/l.vs
Uca�g,
Name as commissioned:
My commission expires:
st 2� f1Qf] Exemptions. The registration provisions of this chapter do not apply to:
by a registered contractor;
1. An authorized representative of the United States
government, the state of Washington, or any incorporated
city, town, county, township, irrigation district, reclamation
district, or other municipal or political corporation or
subdivision of this state;
2. Officers of a court when they are acting within the scope
of their office;
3. Public utilities operating under the regulations of the
utilities and transportation commission in construction,
maintenance, or development work incidental to their own
business;
4. Any construction, repair, or operation incidental to the
discovering or producing of petroleum or gas, or the
drilling, testing, abandoning, or other operation of any
petroleum or gas well or any surface or underground mine
or mineral deposit when performed by an owner or lessee;
5. The sale of any finished products, materials, or articles of
merchandise that are not fabricated into and do not become
a part of a structure under the common law of fixtures;
6. Any construction, alteration, improvement, or repair of
personal property performed by the registered or legal
owner, or by a mobile /manufactured home retail dealer or
manufacturer licensed under chapter 46.70 RCW who shall
warranty service and repairs under chapter 46.70 RCW;
7. Any construction, alteration, improvement, or repair
carried on within the limits and boundaries of any site or
reservation under the legal jurisdiction of the federal
government;
8. Any person who only furnished materials, supplies, or
equipment without fabricating them into, or consuming
them in the performance of, the work of the contractor;
9. Any work or operation on one undertaking or project by
one or more contracts, the aggregate contract price of
which for labor and materials and all other items is less
than five hundred dollars, such work or operations being
considered as of a casual, minor, or inconsequential nature.
The exemption prescribed in this subsection does not apply
in any instance wherein the work or construction is only a
part of a larger or major operation, whether undertaken by
the same or a different contractor, or in which a division of
the operation is made into contracts of amounts less than
five hundred dollars for the purpose of evasion of this
chapter or otherwise. The exemption prescribed in this
subsection does not apply to a person who advertises or
puts out any sign or card or other device which might
indicate to the public that he or she is a contractor, or that
he or she is qualified to engage in the business of
contractor;
io. Any construction or operation incidental to the
construction and repair of irrigation and drainage ditches
of regularly constituted irrigation districts or reclamation
districts; or to farming, dairying, agriculture, viticulture,
horticulture, or stock or poultry raising; or to clearing or
other work upon land in rural districts for fire prevention
purposes; except when any of the above work is performed
11. An owner* who contracts for a project with a registered
contractor, except that this exemption shall not deprive the
owner of the protections of this chapter against registered
and unregistered contractors. The exemption prescribed in
this subsection does not apply to a person who performs
the activities of a contractor for the purpose of leasing or
selling improved property he or she has owned for less than
twelve months;
12. Any person working on his or her own property,
whether occupied by him or her or not, and any person
working on his or her personal residence, whether owned
by him or her or not but this exemption shall not apply to
any person who performs the activities o of contractor n on
his or her own property for the purpose selling,
demolishing, or leasing the property;
13. An owner* who performs maintenance, repair, and
alteration work in or upon his or her own properties, or
who uses his or her own employees to do such work;
14. A licensed architect or civil or professional engineer
acting solely in his or her professional capacity, an
electrician certified under the laws of the state of
Washington, or a plumber certified under the laws of the
state of Washington or licensed by a political subdivision of
the state of Washington while operating within the
boundaries of such political subdivision. The exemption
provided in this subsection is applicable only when the
person certified is operating within the scope of his or her
certification;
15. Any person who engages in the activities herein
regulated as an employee of a registered contractor with
wages as his or her sole compensation or as an employee
with wages as his or her sole compensation;
16. Contractors on highway projects who have been
prequalified as required by RCW 47.28.070, with the
department of transportation to perform highway
construction, reconstruction, or maintenance work;
17. A mobile /manufactured home dealer or manufacturer
who subcontracts the installation, set -up, or repair work to
actively registered contractors. This exemption only applies
to the installation, set -up, or repair of the
mobile /manufactured homes that were manufactured or
sold by the mobile /manufactured home dealer or
manufacturer;
18. An entity who holds a valid electrical contractor's
license under chapter 19.28 RCW that employs a certified
journeyman electrician, a certified residential specialty
electrician, or an electrical trainee meeting the
requirements of chapter 19.28 RCW to perform plumbing
work that is incidentally, directly, and immediately
appropriate to the like -in -kind replacement of a household
appliance or other small household utilization equipment
that requires limited electric power and limited waste
and /or water connections. An electrical trainee must be
supervised by a certified electrician while performing
plumbing work.
• Per Washington State Department of Labor and Industries, lessee has been
interpreted to be equivalent to owner for the purpose of these exemptions.