Loading...
HomeMy WebLinkAboutPermit D09-058 - AFT WASHINGTON - TENANT IMPROVEMENTAFT WASHINGTON 625 ANDOVER PK W D09 -058 Parcel No.: 2623049143 Address: 625 ANDOVER PK W TUKW Suite No: Tenant: Name: AFT WASHINGTON Address: 625 ANDOVER PK W , TUKWILA WA Cityrlf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Owner: Name: SOUTHCENTER CORPORATE SQUAR Address: 150 CALIFORNIA ST , SAN FRANCISCO CA 94111 Phone: DEVELOPMENT PERMIT Contact Person: Name: TAMARA GENZALE Address: 635 ANDOVER PK W SUITE 107 , TUKWILA WA 98188 Phone: 206 -575 -3080 Contractor: Name: D P INC GENERAL CONTRACTORS Address: 19909 BALLINGER WAY NE , SEATTLE, WA 98155 Phone: 206- 361 -2989 Contractor License No: DPINCGC066BU doc: IBC -10/06 * *continued on next page ** Permit Number: D09 -058 Issue Date: 05/11/2009 Permit Expires On: 11/07/2009 Expiration Date: 01/31/2010 DESCRIPTION OF WORK: TENANT IMPROVEMENT TO PART OF FIRST FLOOR FOR OFFICE USE TO INCLUDE DEMOLITION OF EXISTING PARTITIONS AND ADDITION OF NEW PARTITIONS, DOORS, RELITES AND OTHER FEATURES Value of Construction: $22,382.00 Fees Collected: $833.13 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: V -B Occupancy per IBC: 0008 D09 -058 Printed: 05 -11 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Water Meter: Permit Center Authorized Signature: doc: IBC -10/06 City oliTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Water Main Extension: Private: Public: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N N N N Start Time: Volumes: Cut 0 c.y. Start Time: Permit Number: D09 -058 Issue Date: 05/11/2009 Permit Expires On: 11/07/2009 Number: 0 Size (Inches): 0 End Time: Fill 0 c.y. End Time: Date: I ('ll I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t pe ormance f wo . I am authorized to sign and obtain this development permit. �} Signature: ' Date: 5 - / I ' _I Print Name: t) 0 5 e / to-,5 S 1 c- t� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -058 Printed: 05 -11 -2009 Parcel No.: 2623049143 Address: Suite No: Tenant: doc: Cond -10/06 o • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 625 ANDOVER PK W TUKW AFT WASHINGTON 1: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 11: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) D09 -058 ISSUED 04/20/2009 05/11/2009 2: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 4: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface m accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 nun) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 5: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 6: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 7: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 8: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 9: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 10: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 12: Gates serving the means of egress system shall comply with the requirements of the International Fire Code. Gates used as a component in a means of egress shall conform to the applicable requirements for doors. (IFC 1008.2) D09 -058 Printed: 05 -11 -2009 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 13: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 14: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 15: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 16: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 17: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 20: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 21: ht order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 22: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 26: ** *PUBLIC WORKS DEPARTMENT CONDITIONS*** 27: Prior to final permit sign -off 2" Reduced Pressure Principle Assembly (RPPA) permited under PW09 -043 shall be instaleed, inspected and finaled. 28: ** *BUILDING DEPARTMENT CONDITIONS * ** 29: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 30: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). doc: Cond -10/06 D09 -058 Printed: 05 -11 -2009 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 31: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 32: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 33: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 34: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** D09 -058 Printed: 05 -11 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. 0 Rct 5 51'e,- Signature: Print Name: doc: Cond -10/06 D09 -058 Date: V I ordinances governing or local laws regulating Printed: 05 -11 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cLtukwila.wa.us Building Permit No. J Mechanical Permit No. Plumbing /Gas Permit No Public Works Permit No. Project No. Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** p er" ,p'' 2b 7O 1 CI I �� Site Address: k t �i d(O1/C pa 1 ecA \JV tti Suite Number: I I I Floor: New Tenant: g Yes ❑..No Tenant Name: A �/If �M Property Owners Name: `i iCil Y t R1 If 5 Mailing Address: t t oI t cecinci Ave, So i-e It"1 O King Co Assessor's Tax No.: City sec1tt e V\I c D State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: TAVYY1V Ct eel Ti Day Telephone: Mailing Address: b , � 61W� 1' RIM vieS City E -Mail Address: gem Cite@ 2Vfl1O C0W1 Fax Number: ` E -Mail Address: Company Name: Mailing Address: s t� l t ett GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: vote-yin S tr\- '"v `ue 174. - �p [ -} ,� d Mailing Address: 2 2 1 V' Y1 4 `�+ Ct 1 � V V 12- City Zip Contact Person: aCAS Day Telephone: t st State t t . ` c Q Y 1� iA� V ,Y' t i .COy ax Number: 200. 44" I. 4 1 .- t ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applications\Pomrs- Applications On Line\2009 Applications\1 -2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 2 2 /2- Scope of Work (please provide detailed information): — GA Y . .- f.QV oV off, * U"i cierY1Al ti 10/1 0 e< ng \r-1e c fecit Xe Will there be new rack storage? ❑ Yes H:\Applications\Forms- Applications On Line\2009 Applications \I-2009 - Permit Application.doc Revised: 1 -2009 bh Existing Building Valuation: $ �.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage elow PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 7 4 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes tA No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure N � e / w y� Type o Construction per IBC Type of Occupancy per IBC 1 Fioor �` y o4-) � ' nom ` / V 2nd Floor 3' Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 2 2 /2- Scope of Work (please provide detailed information): — GA Y . .- f.QV oV off, * U"i cierY1Al ti 10/1 0 e< ng \r-1e c fecit Xe Will there be new rack storage? ❑ Yes H:\Applications\Forms- Applications On Line\2009 Applications \I-2009 - Permit Application.doc Revised: 1 -2009 bh Existing Building Valuation: $ �.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage elow PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 7 4 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes tA No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT'APPLICATIONNOTES — Applicable to all permits in this application r Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 1 ER 1' • UTHORIZE I N Signature: Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). As v wiv -iev c r oIVI-rovn City 01 c Date: �y �{�. /�� pl } Day Telephone: 2 Oo - ���' O Mailing Address: (0 ✓ ✓ v �c1 U`ti t� O 1 1/4/101 61gg State Zip Date Application Expires: byq Date Application Accepted: l H:\Applications \Forms - Applications On Line \2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Staff Initials: Page 6 of 6 Parcel No.: 2623049143 Address: 625 ANDOVER PK W TUKW Suite No: Applicant: AFT WASHINGTON Receipt No.: R09 -00596 Initials: User ID: Payee: WER 1655 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2423 833.13 Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us SOUTHCENTER CORP SQUARE Account Code Current Pmts 000/322.100 000/345.830 640.237.114 RECEIPT Total: $833.13 Permit Number: D09 -058 Status: PENDING Applied Date: 04/20/2009 Issue Date: Payment Amount: $833.13 Payment Date: 04/20/2009 11:20 AM Balance: $0.00 502.20 326.43 4.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 04 -20 -2009 Project: �-�- / �r J� L W six., ` °' Type ogrispecti n: o t-� A, I • / �:�� l Addrgss: n 0 J n - Date Called: Special Instructions: /. Date Wanted: Requester: Phone r 0 3 _ Q 510( INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION if- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. Corrections required prior to approval. 4 COMMENTS: - f f AA . T ( .-a P Inspe Date: ? ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: F7`. L..) 15 ti i cv.Te raj Type of Inspection: 1-=- R A nT c NJ (, Address: (07S A,iIA6VeP Pew Date Called: Special Instructions: Date Wanted: ` S — 1 Z 6 r � CQ9 p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION 0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12 ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: l' Inspe Approved per applicable codes. ❑ Corrections required prior to approval. Rec No.: Q AV" IN r � "Pi) iNt&f !' • 1) Date: 5 - 1Z v�v 60.00 REINSPECTION F�E REQUIRED. Pr or to inspection, fee must be aid at 6300 Southcenter lvd., Suite 100. all to schedule reinspection. Date: Dog- OS bob -dS Z Project: A csT Type of Inspection: sr -rive -1, j -r - CNt4-1..._ Address: 6v.s� /j-P kJ Suite #: //J Contact Person: 1,^12-4-7 6t64-t Hood & Duct: 1- Special Instructions: Phone No.. .13 7?:.? - 45"� { Needs Shift Inspection: Sprinklers: Fire Alarm: }-• Hood & Duct: 1- Monitor: 0 , N tie... Pre -Fire: 7 Permits: 0 Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 0 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. ri Corrections required prior to approval. COMMENTS: - ( r ,o h a Inspector: I Date: 5- Hrs.: 47/ 1 _ $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13 /06 T.F.D. Form F.P. 113 Project: /- FT" Sprinklers: Type of Inspection: FA FI ct. I Address: cp - Ahd (3ve Suite #: 1 / ) Pic w Contact Person: Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre- Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT floe -off 09 -tom PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 J jApproved per applicable codes. I I Corrections required prior to approval. COMMENTS: 14 F I 0 r: 4o/vi Date: -d c r/ �r■ $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc T.F.D. Form F.P. 113 P r o j e c t : A c T C . J r4-s , N i t ° ' Type of Inspection: Address: L s Suite #: 7' p 0 j Contact Person: Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East,' Tukwila, Wa. 98188 n Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT spection Record Form.Doc 1/13/06 `)9.- os- PERMIT NUMBERS 206- 575 -4407 Corrections required prior to approval. COMMENTS: Qd roraA• -e slue- cfgfe, P /.a,✓ Inspector: fC Date: Sid / o� Hrs.: 1 rs.. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. CaII to schedule a`reinspection. T.F.D. Form F.P. 113 Project: /1- 57 Type of Inspection: S ett ,...t. Lc_ Address: 62 A IP tn/ Suite #: t t Contact Person: C,( ava P Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy ape: INSPECTION NUMBER - Approved per applicable codes. Word/Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit Date: 5/1310 Dpi -OS 3 s9_ o?3 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Corrections required prior to approval. COMMENTS: (A u Cov c- Inspector: / / ) 2 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Hrs.: 1/13/06 T.F.D. Form F.P. 113 4 April 27, 2009 Tamara Genzale 635 Andover Pk W, Ste 107 Tukwila WA 98188 RE: CORRECTION LETTER #1 Development Permit Application Number D09 -058 AFT Washington — 625 Andover Pk W Dear Ms. Genzale, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time the Building, Fire, and Planning Departments have no comments. Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. I have also enclosed a Non - Residential Sewer Use Certification that must be completed prior to issuance of the permit. Corrections /revisions must be made in person and will not be accepted throujh the mail or by a messenker service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, fer Marshall t Technician encl File No. D09 -048 • City of Tukwila P:\Permit Center\Correction Letters\2009\D09 -058 Correction Letter #1.DOC wer • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DATE: August 24, 2009 PROJECT: AFT Washington 625 Andover Pk West (P:Joanna/Comments 1 D09 -058 PW) • 1 PUBLIC WORKS DEPARTMENT COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards REVIEW #: 1 PERMIT NO: D09 -058 PLAN REVIEWER: Contact Joanna Spencer at (206) 431 -2440 if you have any questions regarding the following comments. 1) Please revise your Site Plan 1 on sheet TI -1 to include individual building numbers and show the nearest streets, Andover Pk West and Corporate Dr North to avoid confusion in project site location. 2) In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross - connection control program to protect the public water system from contamination via cross - connection. The City has determined that the subject building has deficiencies on the domestic water service line. a) Domestic Water Service A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPPA) shall be installed immediately downstream of the existing permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box/Hot Rock or equal freeze protection enclosure anchored to a minimum 4" concrete pad. Public Works strongly recommends a power supply for the freeze protection enclosure. On your site plan please show the property line(s), street name, North arrow, building location and size of existing permanent water meter and proposed RPPA. Show manufacturer name and backflow model number and size. Submit RPPA cut sheet. I have enclosed Development Bulletin C5, which spells out design and installation requirements for cross connection control. A separate letter was mailed to Meriwether Partners, representing the property owner. The Public Works Director will withhold issuance of this Tenant Improvement permit until the Permit Center receives plans for RPPA installation or a bond in the amount equal to 150% of the design, installation, and RPPA testing cost together with a letter stating the installation by a certain date. ACTIVITY NUMBER: D09 -058 DATE: 05 -05 -09 PROJECT NAME: AFT WASHINGTON SITE ADDRESS: 625 ANDOVER PK W X Response to Correction Letter # 1 DEPARTMENTS: Building Division ITublic Work A-, DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Comments: TUES /THURS ROUTING: Please Route ❑ REVIEWER'S INITIALS: Original Plan Submittal APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 11 4 3 ERMIT COORD COPY 4111 PLAN REVIEW /ROUTING SLIP Fire Prevention Planning Division Structural Incomplete ❑ n Response to Incomplete Letter # Revision # After Permit Issued DUE DATE: 05-07 -09 DATE: DATE: Permit Coordinator Not Applicable Structural Review Required 1 No further Review Required n Approved 1 1 Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: n u Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 06-04-09 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: o • v MHO 'ry PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D09 -058 PROJECT NAME: AFT WASHINGTON SITE ADDRESS: 625 ANDOVER PK W X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: Vu - Tiding b'vision Public Works Complete Comments: Documents/routing slip.doc 2 -28 -02 DETERMINATION OF C9IVIPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: 1,� Jai NSA- 1 )-1-0ct Fire Prevention �_!, Planning Division p.L/ 611 Structural Incomplete DATE: 04 -20 -09 Response to Incomplete Letter # Revision # After Permit Issued n Permit Coordinator DUE DATE: 04-21-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS RO ING: Please Route Structural Review Required REVIEWER'S INITIALS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: No further Review Required DATE: DUE DATE: 05-19-09 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: \applicatinns\I rrms- applicetion, on line\rovisivn submittal Created: 8 -13 -2004 Revised' City of Tukwila Department of Cotntntuiity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http:iAvu'w.ei.tukwi/a.wu.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fix, etc. Date: Oat 5 2 °O ° I ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: AFT Washington Project Address: 625 Andover Pk W Plan Check/Permit Number: D09-058 Contact Person: TAVV G1/ Z l e Phone Number: 2--Ob • �1S Summary of Revision: QL Sheet Number(s): "Cloud" or highlight al! areas of revision including date of revision Received at the City of Tukwila Permit Center by: k cf Entered in Permits Plus on OG/ CITY OF TUKVV/tA MAY 0 5 2009 PERMIT CENTER License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status PATTICCO34MH PATTISON CONSTRUCTION CO LLC CONSTRUCTION CONTRACTOR GENERAL UNUSED 7/8/1997 2/17/1998 ARCHIVED PATTICA066DQ PATTISON CONSTRUCTION Et ASSOC CONCONSTRUCTSTRUCTR ION GENERAL UNUSED 3/18/19942/17/1998ARCHIVED DODSOPI101J8 DODSON PATTISON INC CONSTRUCTION CONTRACTOR GENERA UNUSED 4/2/1990 3/26/1994 ARCHIVED ACECO. *179L0 ACE CONSTRUCTION CONSTRUCTION CONTRACTOR CARPENTRY /FRAMING PAINTING /WALLCOVERING 6/20/1983 6/16/1986 ARCHIVED VANSND`176B0 VAN'S NORTHWEST DRYWALL CONSTRUCTION CONTRACTOR DRY WAL PAINTING /WALLCOVERING 1/20/1983 11/1/1983 ARCHIVED ALLAMD *1846N ALL AMERICAN DRYWALL CONSTRUCTION CONTRACTOR DRY WALL PAINTING /WALLCOVERING 1/15/19821/15/1983 ARCHIVED Name Role Effective Date Expiration Date DODSON, WILLIAM PRESIDENT 01/31/1994 Bond Amount Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 DEVELOPERS STY Et DEMNITY CO 7 91078C 01/31/2008 Until Cancelled $12,000.0002/25 /2008 4 CBIC SA6377 01/31/200201/31/2008 $12,000.00 01/09/2002 3 CBIC SA6377 01/31/1998 01/31/2002 $6,000.00 2 CBIC SA6377 01/31/199701/31 /1998 $6,000.00 AMERICAN Untitled Page 0 • General /Specialty Contractor A business registered as a construction contractor with Lftl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name D P INC GENERAL CONTRACTORS Phone 2063612989 Address 19909 BALLINGER WAY NE Suite /Apt. City State Zip County Business Type Parent Company SEATTLE WA 98155 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601515833 ACTIVE DPINCGC066BU CONSTRUCTION CONTRACTOR 1/31/1994 1/31/2010 GENERAL UNUSED Other Associated Licenses Business Owner Information Bond Information Page 1 of 2 https://fortress.wa.gov/lni/bbip/Detail.aspx 05/11 /2009 71 ABBREVIATIONS 13 ACT ACOUSTICAL CEILING TILE ADJ ADJACENT /ADJUSTABLE AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM APPROX APPROXIMATELY @ AT BLDG BLKG B/S CAB CLR CLG CL COL COMM COMP CONST CONT CPT CT DIA DIM DR DW DWG E EA ELEC ELEC'L ELEV EXIST EXT FIN FLR FLUOR FR FT FURN GA GALV GD GL GWB HC HDW HM HT HVAC IN INCL INSUL INT NOT USED BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN COMMUNICATION COMPOSITION CONSTRUCTION CONTINUOUS CARPET CERAMIC /CONCRETE TILE DIAMETER DIMENSION DOOR DISHWASHER DRAWING EXISTING, EAST EACH ELECTRIC ELECTRICAL ELEVATION (VIEW) EXISTING EXTERIOR FINISH FLOOR FLUORESCENT FIRE RATED FEET FURNISH /FURNISHINGS GAUGE GALVANIZED GARBAGE DISPOSAL GLASS /GLAZING GYPSUM WALL BOARD HOLLOW CORE HARDWARE HOLLOW METAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR JT LL @TE LF MAX MECH MFR MIN MISC MTD MTL MW N/A N.I.C. NO NOM NTS OC OPNG OPP ORIG PERM PL PLAM PLYWD PR PTR R RB REF REINF REQ'D REV RM RO S SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP TEL TYP VCT VERT W W/ W/o WC WD JOINT BY LANDLORD AT TENANT'S EXPENSE LINEAL FOOT MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL MICROWAVE OVEN NORTH, NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PERMANENT PLATE PLASTIC LAMINATE PLYWOOD PAIR PARTITION RADIUS, REMOVE, RELOCATE RUBBER BASE REFRIGERATOR REINFORCING REQUIRED REVISION /REVERSE ROOM ROUGH OPENING SOUTH SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TELEPHONE TYPICAL VINYL COMPOSITION TILE VERTICAL WEST WITH WITHOUT WALLCOVERING WOOD EXISTING LOBBY LONGEST TRAVEL DISTANCE: 112' -8" EXISTING CORRIDOR CO EXISTING OFFICE SQ. FOOTAGE = 3,232 S.F. 3,232 S.F. @ 1:100 = 33 OCCUPANTS (1) EXIT REQUIRED; (2) EXITS PROVIDED. NO CHANGE IN USE NO CHANGE IN OCCUPANCY NO CHANGE IN BUILDING AREA NO SHELL /CORE OR STRUCTURAL WORK NO CHANGE TO SUITE AREA EXITING PLAN W/ OCCUPANCY INFO. 1,20 " =1' -0" NOTES: 1. PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT, THE ELECTRICAL CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS, THE ELECTRICAL CONTRACTOR IS TO NOTIFY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS TO NOTIFY MS &A OF THE CONFLICT(S) SO A NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED. 2. CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTING PER CODE. DESIGN PROVIDED AS CONCEPTUAL ONLY. 3. CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE TO CURRENT CODES AS NECESSARY. 4. CONTRACTOR TO UPGRADE AUDIBLE AND VISUAL ALARMS TO CURRENT CODES AS NECESSARY. COMMON PATH OF EGRESS TRAVEL: 58' -0" 5. THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF V.A.V. BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY MS&A PRIOR TO ANY INSTALLATION. THIS IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY DAMAGED CEILING TILES AND GRID OR EXTENDING ACT CEILING OR GWB CEILING AS NECESSARY TO MATCH EXISTING AS REQUIRED. 7. DAYLIGHT ZONE CONTROL: ALL DAY LIGHTED AREAS AS DEFINED IN CHAPTER 12, BOTH UNDER OVERHEAD GLAZING AND ADJACENT TO VERTICAL GLAZING, SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, WHICH CONTROLS THE LIGHTS INDEPENDENT OF THE GENERAL LIGHTING AREA PER 1513.3 OF THE WASHINGTON STATE ENERGY CODE. 8. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF FIRE SPRINKLERS DESIGN AND CONSTRUCTION. IN THE EVENT OF A CONFLICT REGARDING NEW LIGHTS, WALLS, SOFFITS, AND OTHER FIXTURES, THE SPRINKLER HEADS MUST BE MOVED. 9. COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUTOFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS NOTE. SWEEP CONTROLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. 9 1 CEILING NOTES L -1 EXISTING B/S 2' -0" x 2' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO BE REMOVED. r7 EXISTING B/S 2' -0" x 2' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN. EXISTING B/S 2' - x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN. L • , EXISTING B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO BE REMOVED /RELOCATED. RELOCATED B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE. NEW OR UPGRADED B/S 2' -0" x 4' -0" RECESSED FLUORESCENT EMERGENCY LIGHT FIXTURE. ® B/S EXIT SIGN N= NEW, E= EXISTING (DIRECTIONAL WHERE SHOWN) B/S SWITCH. "N" = NEW _L141 CEILING LEGEND (2) #10 SCREWS CORPORATE DRIVE NORTH 8 CORPORATE DR SOUTH EXISTING 2 -STORY OFFICE EUILDING a w 0 0 z 1 NORTH MINKLER BLVD. 1 SITE PLAN NOT USED REVEAL (PAINT BLACK) OR MATCH EXISTING. [[[[[[[[[[[[[t 1/8" BLACK FOAM TAPE HOLD BACK 1/4" FROM EDGE OF TRACK. LATERAL BRACING TENANT WALLS (NO CASEWORK) NTS � 8' MAX r 8' MAX MAX � 8' MAX MAX MAX 2' MAX LATERAL BRACING PER DETAIL ABOVE (TYP.) NOTES: 1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FT. LONG. (PER TYP. PART. PLAN) 2. TEMPORARY ATTACHMENT OF PARTITION TOP TRACK TO THE GRID IS PERMITTED TO ALIGN AND SET THE WALL UNTIL PERMANENT BRACING IS PROVIDED. REMOVAL OF THE TEMPORARY HOLDING SCREWS IS UP TO THE DISCRETION OF THE SPECIFIC LOCAL BUILDING OFFICIAL. CONTRACTOR TO VERIFY. 3. PROVIDE BRACING AT ANY PERMANENTLY PARTITION THAT IS NOT ATTACHED TO CEILING GRID. 10 PARTITION HEAD BRACING DETAIL 11/2 " =1' -0" 11 6" UNLESS OTHERWISE NOTED DOOR NUMBER TYPE OF DOOR A. B/S 3' -0" WIDE X FULL HEIGHT S.C. WOOD DOOR & B/S FRAME. MATCH EXISTING CONDITIONS. HARDWARE 15 DOOR SCHEDULE a. B/S LATCHSET 0 DENOTES EXISTING DOOR METAL STUDS STAGGERED @ 8' -0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12 ATTACH TO STRUCTURE ABOVE W/ HILTI POWER DRIVEN FASTENER3 /4" MIN. CONTINUOUS CEILING GRID - DO NOT CUT. SUSPENDED CEILING. 21/2" X 25 GA. STL. STUDS @ 24" O.C. W/ 5/8" GWB, TYPE 'X', EACH SIDE. NOTES: 1. ALL DOOR HARDWARES SHALL HAVE B/S LEVER TYPE HANDLES, ANSI 117.1 COMPLIANT AND HAVE B/S FINISH. 2. RE -USE EXISTING DOORS SCHEDULED FOR REMOVAL WHEREVER POSSIBLE. DOORS TO BE RE -USED ARE TO BE TOUCHED -UP TO BRING INTO "LIKE NEW" CONDITION. NTS VICINITY MAP Ti NOT USED REVEAL (PAINT BLACK) OR MATCH EXISTING CONDITION. 1/8" BLACK FOAM TAPE HOLD BACK 1/4" FROM EDGE OF TRACK ALIGN UPLAND DR. MIDLAND DR TRILAND DR. cc a Lu 0 0 T ▪ EXISTING B/S FULL HEIGHT RELITE i.405 STRANDE R BLVD. �/ MINKL: R B VD. W-u1la 16 CONSTRUCTION LEGEND SOUTHCENTER CORPORATE SQUARE NORTH SEISMIC BRACING PER 1O/TI -1. 1/4" NON -COMB. WD FILLER UNDER MAIN RUNNERS CONTINUOUS CEILING GRID - DO NOT CUT. LINE OF CEILING GRID BEYOND, SEE R.C.P. CONT. 'L' METAL TRIM W/ PAPER WING CONT. 2 1/2" x 1 1/4" 25 GA. TRACK WI (2) #10 SCREWS @ 24" O.C. 5/8" FIRE RETARDANT PLYWOOD BLOCKING @ WALL HUNG ITEMS (WHERE APPLICABLE - REFER TO DRAWING PLANS) ALTERNATE #1 FOR BLOCKING: 20" WIDE GALV. SHEET METAL @ +40" FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING) HEAD SECTION P 518" GWB, TYPE 'X' EACH SIDE, TYP. BASE, AS SCHEDULED. - CONT. 25 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS REQ'D. HILTI POWER DRIVEN FASTENER 3/4" MIN. I EMBEDMENT @ 24" O.C. OR SIMILAR. BASE SECTION 2 1/2" x 25 GA. GALV. STEEL STUD @ 24" O.C. WITH 5/8" TYPE 'X' GWB EACH SIDE. PLAN VIEW STANDARD TENANT PARTITION EXISTING BUILDING CORE AREA, TO REMAIN UNALTERED EXISTING B/S CORRIDOR PARTITION TO REMAIN. EXISTING B/S CONSTRUCTION TO REMAIN. EXISTING CONSTRUCTION ASSEMBLY TO BE DEMOLISHED. NEW B/S TENANT INTERIOR PARTITION: 2 1/2" METAL STUDS WITH 5/8" GWB EACH SIDE FROM FLOOR TO UNDERSIDE OF HUNG CEILING. SEE 11/TI -1. N = 1 = NEW B/S FULL HEIGHT RELITE: FULL HT. IN B/S WOOD FRAME WITH TEMPERED SAFETY GLASS AS REQUIRED. NTS 1 1/2 " =1' -0" 12 SCOPE OF WORK: TENANT IMPROVEMENT TO PART OF THE FIRST FLOOR FOR OFFICE USE TO INCLUDE DEMOLITION OF EXISTING PARTITIONS AND ADDITION OF NEW PARTITIONS, DOORS, RELITES, LIGHTING, AND OUTLETS. SITE ADDRESS: 625 ANDOVER PARK WEST, TUKWILA, WA 98188 PARCEL NUMBER: 51- 0599163 LEGAL DESCRIPTION: ALL THAT CERTAIN REAL PROPERTY SITUATED IN THE CITY OF TUKWILA, COUNTY OF KING STATE OF WASHINGTON, BEING A PORTION OF THE EAST 1/2 OF THE NORTHWEST 1/4 OF THE SOUTHEAST 1/4 OF SEC. 26, T.23N, R.4E, W.M., AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE INTERSECTION OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4 WITH THE WESTERLY MARGIN OF ANDOVER PARK WEST (59TH AVENUE SOUTH), DISTANT ALONG SAID NORTHERLY LINE N88 °05'42 "W 1369.34 FEET FROM THE NORTHWEST CORNER OF SAID SOUTH- EAST QUARTER; THENCE FROM SAID POINT OF BEGINNING ALOND SAID WESTERLY MARGIN S01 °47'29 "W 451.30 FEET; THENCE LEAVING SAID WESTERLY MARGIN TANGENT TO THE PRECEDING COURSE ALONG THE ARC OF A CURVE TO THE RIGHT HAVING A RADIUS OF 50.00 FEET AND A CENTRAL ANGLE OF 90 °06'49 ", AN ARC LENGTH OF 78.64 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 501.40 SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG SAID PARALLEL LINE N88 °05'42 "W 180.90 FEET TO A POINT ON A LINE THAT IS PARALLEL WITH AND 261.00 FEET WESTERLY OF THE EAST LINE IF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE N01 °47'29 "E 136.00 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 365.40 FEET SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG LAST SAID PARALLEL LINE S88 °05'42 "E 37.50 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 223.50 FEET WESTERLY OF THE EAST LINE OF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE N01 °47'29 "E 100.00 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 265.40 FEET SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG LAST SAID PARALLEL LINE N88 °05'42 "W 12.50 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 236.00 FEET WESTERLY OF THE EAST LINE OF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE N01 °47'29 "E 265.40 FEET TO A POINT ON THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG SAID NORTHERLY LINE S88 °05'42 "E 206.00 FEET TO THE POINT OF BEGINNING AND CONTAINING 2.408 ACRES OF LAND MORE OR LESS. AREA OF SUITE: 3,232 SF OCCUPANCY: B OFFICE TYPE OF CONSTRUCTION: V -B, SPRINKLERED TENANT: AFT WASHINGTON 14900 INTERURBAN AVE. SOUTH, SUITE 130 TUKWILA, WA 98168-4654 CONTACT: NANCY KENNEDY 206 - 242 -4777 (PHONE) 206 - 242 -3131 (FAX) E -MAIL : nkennedy @aftwa.org BUILDING MANAGEMENT: WASHINGTON HOLDINGS 600 UNIVERSITY STREET, SUITE 2820 SEATTLE, WA 98101 CONTACT: JOEL ASLANIAN 206 - 816 -1573 (PHONE) 206 - 381 -1200 (FAX) E -MAIL : jaslanian @mericap.com DESIGNER: MARVIN STEIN AND ASSOC., LLC 2221 5TH AVE. SEATTLE, WASHINGTON 98121 CONTACT: LISA BOLSTER 206 - 441 -1449 (PHONE) 206 - 441 -4361 (FAX) E -MAIL - I.bolster @marvinstein.com CONTRACTOR: TBD FILE COPY Permit No. Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field and is acknowledged: m7 City Of Tukwila BUILDING DIVISION By Date: 7 1 PROJECT INFORMATION SEPARATE PERMIT REQUIRED FOR: (Q' eahanicai ►electrical V tubing Gas Piping City of Tukwila BUILDING DIVISION 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. 2. CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN CONTRACT DRAWINGS & SPECIFICATIONS FOR BUILDING. 3. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 4. B/S INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD DRAWN AND /OR SPECIFIED IN BUILDING CONTRACT DOCUMENTS. 5. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED, FOR SEISMIC CONDITIONS, IN BUILDING JURISDICTIONS WHERE APPLICAP_E. 6. CONTRACTOR TO PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS. 7. CONTRACTOR SHALL ALIGN OR FURR ALL INTERIOR PARTITIONS SO THAT FINISHES REMAIN FLUSH IN ROOMS AND CORRIDORS REGARDLESS OF DIFFERENCES IN PARTITION WIDTHS. 8. CONTRACTOR TO PROVIDE LEVELING THROUGHOUT THE SPACE FOR PROPER INSTALLATION OF EQUIPMENT, PARTITIONS, DOORS, GLUE -DOWN CARPET, ETC, TOLERANCE OF 1/4" IN 10' -0" DIFFERENCE IS ACCEPTABLE. GENERAL NOTES HVAC: 1. RECONFIGURE AS REQUIRED FOR ALTERATIONS. 2. REBALANCE HVAC SYSTEM. 3. CLEAN ALL EXISTING GRILLES. 4. VERIFY AND RELOCATE THERMOSTATS AS NECESSARY. FIRE LIFE SAFETY: 1. ALL FIRE EXTINGUISHERS, HORN STROBES, EXIT SIGNS AND SPRINKLER HEADS, ETC. TO BE PER CODE, HVAC & FIRE LIFE SAFETY NOTES TI -1 COVER SHEET & DETAILS TI -2 DEMOLITION /CONSTRUCTION PLAN & REFLECTED CEILING PLAN 17 DRAWING INDEX REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 7 2009 C ity of Tukwila `7 BUILDING DIVISION 04 MAY 0, 5 2009 PERMIT CENTER CORRECTION LTR # �L_ D01--05 NO. n TENANT: SHEET TITLE: SOUTH CENTER CORPORATE SQUARE, BLDG 5 625 ANDOVER PARK WEST TUKWILA, WA 98188 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal cnd may include additional plan review fees. REVISIONS /ISSUANCE: Marvin Ste planning 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 CHECKED BY: LB, GG DRAWN BY: CL, LW, MW REVISIONS INDICATED THUS n GENERAL REVISIONS REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2009. AFT FIRST FLOOR) COVER SHEET & DETAILS sociates, LLC design JOB NO.: 99135.067 DATE: 04/09/09 SCALE: AS NOTED DATE 04/30/09 TI -1 OF CC n 1• r COMMON LOBBY DEMOLITION/ CONSTRUCTION KEYNOTES: N.I.C. 0 PROVIDE LOCKING HARDWARE ON SERVER ROOM IF NOT ALREADY INSTALLED.VERIFY IN FIELD O PROVIDE AND INSTALL NEW DISHWASHER, AND FULL SIZE REFRIGERATOR. INSTALLATION OF NEW DISHWASHER WILL REQUIRE ALTERATION TO EXISTING BREAK ROOM CABINETS. O PROVIDE AND INSTALL NEW 2'D 8'L BIS COUNTER TOP AT 40" A.F.F. WITH (2) 12 "D ADJUSTABLE SHELVES ABOVE, ENTIRE LENGTH. 4O PROVIDE AND INSTALL NEW 20 "D X 61 BIS COUNTER TOP AND BASE CABINETS WITH 12 "D X 61 B/S UPPER CABINETS ABOVE 0 EXISTING SINK CABINET TO REMAIN. O REMOVE EXISTING VCT FLOORING 0 7 EXISTING VCT FLOORING TO REMAIN rL7 1 0 0 0 0 0 z F- 0) w DEMOLITION /CONSTRUCTION PLAN 118 " =1' -0" 0 5' 10' 20' 30' NORTH 0 N.I.C. ■ N.I.C. EXISTING CORRIDOR N 0 v SERVER 103 BREAK 1 102 1 OFFICE RECEPTION 13' -4" SHARED OFFICE 1 120 1 1 100 1 o OPEN WORK o Fh 1 119 1 1 18 1 OFFICE ci W 7 0 1 104 1 100 HALL A 105 lAla 106 A a —ALIGN 11081A1al 1 17 1 OFFICE ALIGN PTN. MUL FACE 0 9' " E DEMOLITION/ CONSTRUCTION NOTES: EXIT VESTIBULE 6-0" 1. REMOVE EXISTING CARPET AND WALL BASE THROUGH -OUT. 2. A CLEAR PATH SHALL REMAIN AVAILABLE AT ALL TIMES DURING CONSTRUCTION. 3. ALL WALL INFILLS ARE TO ALIGN WITH ADJACENT SURFACES ON BOTH SIDES. 4. PROVIDE AND INSTALL BLOCKING FOR ALL DOORS, ACCESSORIES AND CASEWORK AS REQUIRED. 5. INSTALL TENANT PROVIDED COAT HOOKS ON BACK OF ALL PRIVATE OFFICE DOORS. E 6" PTN. /GLAZ. TYP. CONFERENCE 105 1 OFFICE 106 109 110 114 115 COPY 107 SUPPLIES -1 108 1 OFFICE OFFICE OFFICE 111 CLOSET 1 112 1 OFFICE 113 OFFICE OFFICE CLOSET PTN. /MUL. EDGE PTN. /MUL. PTN. /MUL. PTN. /MUL. PTN, /MUL. 4 6 (1 0) COW COMMON LOBBY EXISTING CORRIDOR n 118 " =1' -0" CC Pr REFLECTED CEILING PLAN 0 5' 10' �I 20' REFLECTED CEILING NOTES 1O B/S WALL MOUNTED UPPER CASEWORK N.I.C. 30' NORTH 0 N.I.C. REFLECTED CEILING KEYNOTES: 1. SEE 14/TI-1 FOR CEILING LEGEND 2. SEE131TI -1 FOR CEILING SUPPORT DATA 1 LIGHTING CALCULATION EXIT VESTIBULE PERCENTAGE OF ALTERATION 16 RELOCATED /44 EXISTING FIXTURES x 100 % = 36.0% SUMMARY THERE ARE NO ADDED OR REMOVED FIXTURES, THUS, THERE IS NO CHANGE IN WATTAGE. PERCENTAGE OF ALTERATION IS LESS THAN 60 %. 105 109 1 111 1 112 113 1 114 1 115 EXISTING CEILING TO REMAIN C4> (s) 10) REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 7 2009 City of Tukwila BUILDING DIVISION CITY MAY 0, 5 2009 PERMIT CENTER SOUTH CENTER CORPORATE SQUARE, BLDG 5 625 ANDOVER PARK WEST TU K WI LA, WA 98188 REG ED 0- CHITE T Marvin Ste planning sociates, tic design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: CL, LW, MW JOB NO.: 99135.067 CHECKED BY: LB, GG DATE: 04/09/09 SCALE: AS NOTED REVISIONS /ISSUANCE: N0. A REVISIONS INDICATED THUS A GENERAL REVISION REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2009. D ATE 04/30/09 TENANT: AFT (FIRST FLOOR) SHEET TITLE: DEMOLITION /CONSTRUCTION & REFLECTED CEILING PLAN TI -2 OF 3