Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D09-062 - DHS - TENANT IMPROVEMENT
DEPARTMENT OF HOMELAND SECURITY 12500 TUKWILA INTERNATIONAL BL D09 -062 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Phone: Contact Person: Name: Address: Phone: Contractor: Name: Address: Phone: Contractor Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 CityOf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 7340600602 12500 TUKWILA INTERNATIONAL BL TUKW DEVELOPMENT PERMIT DEPARTMENT OF HOMELAND SECURITY 12500 TUWILA INTERNATIONAL BL, STE 300 , TUKWILA WA INTERNATIONAL GATEWAY EAST LLC 12201 TUKWILA INTL BLVD 4TH FLR , SEATTLE WA 98168 GLENN PARRY 12201 TUKWILA INTERNATIONAL BL, 4 FLOOR , SEATTLE WA 98168 206 730 -4983 SABEY CONSTRUCTION INC. 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA 98168 206 - 281 -4700 License No: SABEYCI033KM $175,000.00 * * continued on next page ** D09 -062 • Permit Number: Issue Date: Permit Expires On: Expiration Date: 01/06/2011 Fees Collected: International Building Code Edition: Occupancy per IBC: D09 -062 06/04/2009 12/01/2009 DESCRIPTION OF WORK: TI TO 3878 SF AREA TO INCLUDE NEW WALLS, CEILING, LIGHTING, AND CARPETING THROUGHOUT SPACE. NO STRUCTURAL WORK. $3,291.38 2006 0008 Printed: 06 -04 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: Land Altering: Volumes: Cut 0 c.y. Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie doc: IBC -10/06 City oiTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Start Time: End Time: Private: Profit: N Private: Permit Number: Issue Date: Permit Expires On: Date: Date: Size (Inches): 0 End Time: Fill 0 c.y. Public: Non - Profit: N Public: abeil4f ed thi permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit. The granting of this permit does not pre construction or the performance wor Signature: IN 1 — ^V •1 Print Name: Maira/Cc 114 %; 4`'c,/ 44-r This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -062 06/04/2009 12/01/2009 D09 -062 Printed: 06 -04 -2009 Parcel No.: 7340600602 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 12: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12500 TUKWILA INTERNATIONAL BL TUKW DEPARTMENT OF HOMELAND SECURITY PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D09 -062 ISSUED 04/22/2009 06/04/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or D09 -062 Printed: 06 -04 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (1FC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 24: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 25: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 26: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's doc: Cond -10/06 D09 -062 Printed: 06 -04 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 29: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 30: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance #2050) 31: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 32: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 33: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 34: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 35: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 36: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 37: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 38: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 39: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 40: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 41: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** D09 -062 Printed: 06 -04 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: /L4 Alcca5 AM km10/ doc: Cond -10/06 D09 -062 ordinances governing or local laws regulating Printed: 06 -04 -2009 • SITE LOCATION- Site Address: 12500 Tukwila International Blvd. Seattle, Washington Tenant Name: Property Owners Name: International Gateway III LLC Mailing Address: 12201 Tukwila International Blvd. 4th floor CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Glenn Parry CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup: /iivww. ci. tulnvila. wa. us Department of Homeland Security E -Mail Address: glennp @sabey.com • • Building Permit No. PO 1 Vly ?_., Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. . . (For once use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 734060- 0602 -03 Seattle Suite Number: 300 Floor: 3 New Tenant: ❑ Yes ® ..No City Day Telephone: (206) 730 -4983 Mailing Address: 12201 Tukwila International Blvd. 4th floor Seattle Wa. 98168 City State Fax Number: (206) 281 -0920 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Sabey Construction Mailing Address: 12201 Tukwila International Blvd. 4th floor Contact Person: Glenn Parry E -Mail Address: 9lennp @sabey.com Contractor Registration Number: CCO1 SabeyC1033KM Company Name: Hazelrigs Architecture & Design, pllc Mailing Address: 5700 Corson Ave S Contact Person: Colleen Hazelrigs E -Mail Address: colleen @HazelrigsArchitecture.com Contact Person: E -Mail Address: H: \Applications\Fonns- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Seattle p Seattle Wa. State City State Day Telephone: (206) 730 -4983 Fax Number: (206) 281 -0920 Expiration Date: 01/12/2011 City State Day Telephone: (206) 957 -0611 Fax Number: (206) 957 -0612 State 98168 Zip Zip Wa 98168 Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Wa. 98108 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: N/A Mailing Address: City Day Telephone: Fax Number: Zip Page 1 of 6 . . . .:-.1 Existing Interior Remodel Addition to Existing Structure New • Type of Construction per IBC • . Type of • . Occupancy per • :.IBC • • .r Floor 37,717 0 0 0 2 °a Floor ' • 35,072 0 0 0 3` Floor 34,597 3,878 0 0 • Floors 4 thru • 33,776 0 0 0 • Basement . . ; Accessory Structure* . Attached Garage is 119,957 Detached Garage . • Attached Carport Deiached Carport Covered Deck 'Uncovered Deck BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 175,000 Existing Building Valuation: $ 10,000,000 Scope of Work (please provide detailed information): Tennannt improvement to 3878 square ft. area to include new walls, Ceilings, Lighting and carpeting throughout space. No structural work for this improvement. Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ® Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? If 'Yes', attach list of materials and storage locations on a separate 8 - 1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1-2009 bh ❑ Yes m No Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date Application Accepted: ofi HAApplications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revise& 1 -2009 bh City BUILDING OWNER OR AUT . 1 '.` AGENT. Signature: s / Date: 04/20/2009 Print Name: Glenn Pa Day Telephone: (206) 730 -4983 Mailing Address: 12201 Tukwila International Blvd Seattle Wa 98168 State Staff Initials: Zip Date Application Expires: ta17/1-1(9c1 Page 6 of 6 Receipt No.: R09 -00609 Payee: SABEY CONSTRUCTION INC City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 7340600602 Permit Number: D09 -062 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 04/22/2009 Applicant: DEPARTMENT OF HOMELAND SECURITY Issue Date: Initials: JEM Payment Date: 04/22/2009 12:14 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 43038 3,291.38 Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 640.237.114 RECEIPT° Payment Amount: $3,291.38 1,992.05 1,294.83 4.50 Total: $3,291.38 PAYMENT RECEIVED doc: Receipt -06 Printed: 04 -22 -2009 Pr ject: ,1 A9 /r�J 6 //o/f: /s�i�.r`! Typepf Inspect' n: ,/ w 7 Address: / - T ...Z /3 Date Called: Special Instructions: / Date Wanted: l g q CV p.m. Requester: Phone No: .2o‘-255 -3 47/ INSPECTION NO. INSPECTION RECORD Retain a copy with permit Inspector: \ v $60: REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: �n Date: &- i I I �a (Receipt No.: 'Date: COMMENTS: ` %. "- a S- Ec Type of I spectio . % n , t n c5 v 1¢, - Sell Nu lls (-Jr A2tJr -e Q J p Date Called _ca. Gam' f ,' Special Instruc • D " 2 � 1 �� t o .sue A 3 02 � I'(as t Date Wanted: � ,I � v Requester: Phone No: o 2,51 - 3 G, 'if IN 1. f • •----, -e - SFF . A ..)(i A 6 p J .( 'j-c f , Project: I � i �T• �'�M - eY� a S- Ec Type of I spectio . % n , t n c5 v 1¢, Add er' ss O j Q Date Called _ca. Gam' f ,' Special Instruc • D " 2 � 1 �� t o .sue A 3 02 � I'(as t Date Wanted: � ,I � v Requester: Phone No: o 2,51 - 3 G, 'if 0o5- 0(02_1 INSPECTION RECORD I Retain a copy with permit INSPECTION NO. PERMIT NO. CITY. O CITY. 4 TUKWILA BUILDING DIVISION V 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. Inspl Corrections required prior to approval. ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ,Date - — O/ Receipt No.: !Date: Proj ct: _ 1 i� d //�9rrl� Type of Inspection: � // �S7l-.S�0'^���/ /.t/ Date Called: Address: 42 ..""Sin 6 % 7 Special Instructions: .. Date Wanted: S;? - 2 O 0 5 � � ••,•: p.m. Requester: Phone No: X4 -- . .575 -36 '7/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ,l)di -p 2 PERMIT NO. fZ.. (206)431 -36 ❑ Approved per applicable codes. COMMENTS: 01< 1 CA Jet � r ^7 nspeccor: El Corrections required prior to approval. r/ Date: $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. - (Receipt No.: 'Date: Pr ect: , . .07 L4 4 ' rX, Type of Inspection: \ 1 1c. L- dq f.,v Address: /-« G 7 �7` D,te Called: Special Instructions: Date Wanted: — 2 / d 9 Requester: Phone No: o e" — I-SS --- 3 67/ INSPECTION RECORD Retain a copy with permit ' 67 INSPECTION NO. 'PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 E l 0 REINSPECTION FE REQU,#ED. Prior to inspection, fee must be d at 6300 Southcenter B vd., Suite 100. Call to schedule reinspection. 1 . Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Dat$ 1 Receipt No.: 'Date: COMMENTS: eis/� tz" , pe of Inspection: rj fr.�n9rn/ L / Date Address: /2 sc�v b k - / U v�---a- : ems! / /...," /!"- . _51, I/ 7'7-t- --,,,, 4 / `►; '7 7_�a f e 4. ii I./ //5 �4 *� U� A."'" Al� 1/ AfrePC /HS b ees -,04, � 1Q "-Li, , ,, Date Wanted: —1- (1 Ci e - 4/... / fN!/� /c '/ 4 ✓I ,I' - riaO /7P� li -71 - ; . Requester: Phone No: ,, ,..?Q 6 -2'55 3 6 Project: imo.i i eis/� tz" , pe of Inspection: rj fr.�n9rn/ L / Date Address: /2 sc�v 1_ Called: Special Instructions: Date Wanted: —1- (1 S es p.m. Requester: Phone No: ,, ,..?Q 6 -2'55 3 6 7 2 Inspect Receipt No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION re ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. ❑ Corrections required prior to approval. 1Date: ❑ $60.00 REIN CTION FEE REQUIRED. Prior to inspection, fee must be paid at 630 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Date: PERMIT COMMENTS: p Afiike A1pf 8,1 4 - k-- 71) o.1 s` eti. - A e 4-1. .,P ‘-t?C. .-- r t _ fli Ff U , N e, -- fG L ..)'. f{ s 6i-4-C ip At/1‘.II . t..).'1 ri,e_fk (4) 4 ( , (.----?- dt Pe_ t &. i r e 6- - t-A-a c c z ', r A•-P _ ee9 4,0A (( r4-? , LJ/-c- . 1. , ..; --' i;. f Date anted: . t n oject: J / J Type of Inspection: Address: 'a' d 712 - d Date Called: Special Instructions: Date anted: a.m. Requester: Phone No: .,q D6 --'J �-r 0 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION • i t 6 300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 orrections required prior to approval. n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: Type of Inspection: Address: i 7 Suite #: Contact Person: Special Instructions: Phone No.: Permits: Occupancy Type: !7 G 1 - ._. , le ■•■ "� Lt C i- k\—t. I— {{ C� LI) 0'1—'7) L t C i i ! t -, ..) L=. C.'C.. u V- tic: 1.. 1 t., ' ) 7 1 S !tom .. 1 p,, ! Project yn� r " ,1 Type of Inspection: Address: i 7 Suite #: Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -lire: Permits: Occupancy Type: INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT Approved per applicable codes. Word /Inspection Record Fonn.Doc INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 E Corrections required prior to approval. 1 jb 1r $8000 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department Call to schedule a reinspection. T.F.D. Form F.P. 113 COMMENTS: T of I -• . •n: , J ..z; /- r , ate Address: /2 3 .7. -, Suite #: Contact Person: Special Instructions: Pre-Fire: € . a - Dl f _. - tt - .41`* V 't 9. 3.9, 9 - P -, e'P kh.i. o e 4o ie- F.s j S .. i ••rip., ( -- tc , - 2' o'- A tt ' r... t)'r l L- ° i i N h GU ci Ir tt r __ . - - - --- _ : ( , Project: ` ,/� 4. II , . r Pi :3 -t=i- k (1v7 - 1-:1 T of I -• . •n: , J ..z; /- r , ate Address: /2 3 .7. -, Suite #: Contact Person: Special Instructions: Pre-Fire: Phone No.: € ! `i 0- L' Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: s��� f ., Pre-Fire: Permits: )ccupancy:Type: INSPECTION NUMBER II ISPECIION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila Via. 98188 E Approved per applicable codes. Word/Inspection Reto PERMIT NUMBERS f ' - R "Corrections required prior to approval. ; tspector: ` 1 $80.00 REINSPECTION FEE RED. You will receive an invoice from the City of Tukwila Finance Department. Cali to schedule a reinspection. Hrs.: T.F.D. Form F.P. 113 . Project: ilv ivim.. iek Slet-- 1 ' , Type of Inspection: S P 00 u 17 c)JC Address: Q...roo r Suite #: S Contact Person: / Special Instructions: Pre-Fire: Phone No.: Needs Shift Inspection: • Sprinklers:• Fire Alarm: Hood & Duct: Monitor: - Pre-Fire: Permits: Occupancy Type: ' . "" • - r. INSPECTION NUMBER Word/Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT • Approved per applicable codes. PERMIT NUMBERS • 444 Andover Park East, Tukwila Wa 98188 206-575-4407 - CorrectionS, required prior to approval. COMMENTS: Jo idia 14/FE 310 / 30 k - - 11) c'leopt OK- 17 edis 14 0„ Sta:Alk- in -- - - Jo We -c die) c 'N,. 17 hi-se c • Inspector:A, y • Date: g/f4 Hrs.: - • • • $80.00 REINSPECTION FEE REQUIRED. You will receive,an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. 1/13/06 T.F.D. Form F.P. 113 Project Info Project Address Department of Homeland Security Date 5/19/2009 12500 Tukwila International Blvd, Third Floor For Buildi,, ent Use •,� � � tit Seattle, WA 98168 Applicant Name: Glenn Parry, Sabey Construction Pja,7 r Applicant Address: 12201 Tukwila Int' l Blvd., 4th Floor, Seattle; . pm ,.. 98 Applicant Phone: 206 - 281 -8700 " I /)f ,,. � � r �+ 1 P/ • Project Description • New Building . Addition '' Alteration • Plans Included ./f /.0 3n ,1« Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive • Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) • No changes are being made to the lighting CODE & space use not changed. ■ Less than 60% of the fixtures new, installed wattage not increased, Location (floor /room no) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 3rd Floor Office 2x4 troffer 2 lamp T -8 fluroescent w /dicer 44 64.0 2816.0 Corridorr 2x4 troffer 2 lamp T -8 fluroescent w /dinmeer 8 697.0 512.0 CODE A' • MPLIAN JUN 2 2009 unvviia s. tiC' ; .I.. Location floor /room no.) ( ) Occupancy Description uP Y Allowed Watts per ft " Area in fe Allowed x Area 3rd Floor Office 1.00 3007.0 3007.0 3rd Floor Cc non Corridor 0.80 697.0 557.6 1 Interior Lighting Summary LTG -I■T 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Re'ised July 2007 Maximum Allowed Lighting Wattage From Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Proposed Watts may not exceed Total Allowed Watts for Interior ciTY MAY 2 0 2009 PERMRCENTE2 Total Allowed Watts 3564. 6 Total Proposed Watts) 3328.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. CORRECTION LTR# 1 VOi • Use' LPA (W /sf) Use' LPA (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments', restaurants/bars' 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'. assembly spaces 1.0 Theater. motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses'', storage areas 0.5 Hotel banquet /conference /exhibition hall 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified laboratory' shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building bbbies (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Qlification Checklist Quali fication Lighting • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. Note: If occupancy type is "Other" and Fixtures: fixture answer is checked, the number of (Section 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector fixtures in the space is not limited by Code. 1 521) or louvers, c) 5 - 60 watt T - 1, T - 2, T - 4, T - 5, T - 8 lamps, and d) hard - wired elec- Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. Interior Lighting Summary (back) LTG -IN,T 2006 Washington State Nonresidential Energy Code Compliance For TABLE 15-1 Unit Lighting Power Allowance (LPA 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. r May 11, 2009 Glenn Parry 12201 Tukwila International Bl, 4 Floor Tukwila, WA 98188 RE: CORRECTION LETTER #1 Development Permit Application Number D09 -062 Department of Homeland Security —12500 TIB, Ste 300 Dear Mr. Parry, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, ifer Marshall it Technician encl File No. D09 -062 • Cizy of Tukwila Department of Community Development P:\Permit Center\Correction Letters \2009009-062 Correction Letter #1.DOC wer Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: May 8, 2009 Project Name: Department of Homeland Security, STE 300 Permit #: D09 -062 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Two adjacent spaces are shown to be created by the new office construction. Please name and identify the intended use for those spaces. 2. Please provide a Washington State Energy code lighting budget compliance form for the new offices. Forms are available on line http: / /www.neec .net/resources /resources.html. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: D09 -062 DATE: 05 -20 -09 PROJECT NAME: DEPT OF HOMELAND SECURITY, STE 300 SITE ADDRESS: 12500 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Building Division ICJ Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 Ilb PERMIT COORD COPY 6 PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator ❑ DUE DATE: 05-26-09 DATE: DATE: Not Applicable Permit Center Use Only ; • . INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS R UTING: Please Route Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DUE DATE: 06-23-09 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D09 - 062 DATE: 04 -22 -09 PROJECT NAME: DEPT OF HOMELAND SECURITY, STE 300 SITE ADDRESS: 12500 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPA TMENTS: ui ding Division SS N/4 1 -O 7 Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Le Comments: APPROVALS OR CORRECTIONS: Permif•Cenfer Use.Only • CORRECTION LETTER MAILED: Departments issued corrections: Documents/routing slip.doc 2- 28-02 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP Bldg G LO-7-0/ Fire Prevention Structural ❑ Incomplete ❑ sr1 AJJA- - i - g -°7 Planning Division Permit Coordinator DUE DATE: 04-23-09 Not Applicable ❑ Permit Center Use Only • i INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 05-2x09 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Fire ❑ Ping ❑ PW ❑ Staff Initials: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 5/A07 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspectoror Plans Examiner Project Name: Dept of Homeland Security, Suite 300 Project Address: 12500 Tukwila International Bl Contact Person: Phone Number: Summary of Revision: Q 7 T 'C , i7J G fN T se77/9r- S (R G=h2 -76p w/ l/ rif/ b TAI& 4L,y /=t/rvrz - wdr?/ i =rte T7 -7 - /? ���j UJ/ // pE2 •y €perz ,P / 17/t'9 ' AtreQe ,uJcv-2 i•< X411 /� z MT (2ra/? z/6`/ r/4' 6 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 14 . Entered in Permits Plus on \applicanons\forms- applications on lme\revision submittal Created: 8 -13 -2004 Revised: Plan Check/Permit Number: D09 -062 R Vi OF ILA HAY 2 0 2009 PERMIT CENTER License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SABEYC *953RE SABEY CORPORATION CONSTRUCTION CONTRACTOR GENERAL UNUSED 12/5/2005 12/5/2009 ACTIVE DASCOC`066KD D A S CONSTRUCTION CORP CONSTRUCTION CONTRACTOR GENERAL UNUSED 5/4/1994 5/4/1997 ARCHIVED BERKLC1088CE BERKLEY CONSTRUCTION INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 2/5/1992 2/5/1993 ARCHIVED ARCHIDG132QZ ARCHITECTUAL DEV GROUP INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 11/9/1987 11/9/1992 ARCHIVED SABEYC "141 PH SABEY CORPORATION CONSTRUCTION CONTRACTOR UNUSED GENERAL 10/8/1986 12/31/2001 ARCHIVED OWPROI "221 RR 0 e W PROPERTIES INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 12/19/197810/1 /1986 ARCHIVED BERKLS*267LP BERKLEY STRUCTURES INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 6/17/1974 12/31/1991 ARCHIVED Untitled Page General /Specialty Contractor A business registered as a construction contractor with L£tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company SABEY CONSTRUCTION INC 2062814200 12201 TUKWILA INT'L BLVD 4TH FLOOR SEATTLE WA 981685121 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601532164 ACTIVE SABEYCI033KM CONSTRUCTION CONTRACTOR 5/14/1997 1/12/2011 GENERAL UNUSED Other Associated Licenses 1 Business Owner Information 1 https://fortress.wa.gov/lni/bbip/Detail.aspx • Page 1 of 3 06/04/2009 ABBREVIATIONS ACT ADJ AFF ALT ALUM APPROX ARCH BLDG BLKG 5/5 BTW CAB CLR CLG CL COL COMM COMP CONST CONT CTR CPT CT DF DIA DIM DR DWG EA ELEC ELEV EXST EXT FE FEC FIN FLR FLUOR FR FT FURN GA GALV GL GRD GWB HC HDW HM HT HVAC IN INCL INSUL I NT JT ACOUSTICAL CEILING TILE ADJACENT /ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM APPROXIMATELY ARCHITECT AT BUILDING BLOCKING BUILDING STANDARD BETWEEN CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN COMMUNICATION COMPOSITION CONSTRUCTION CONTINUOUS CENTER CARPET CERAMIC TILE DRINKING FOUNTAIN DIAMETER DIMENSION DOOR DRAWING EAST EACH ELECTRIC ELEVATION EXISTING EXTERIOR FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FLUORESCENT FIRE RATED FEET FURNISH /FURNISHINGS GAUGE GALVANIZED GLASS /GLAZING GRADE GYPSUM WALL BOARD HOLLOW CORE HARDWARE HOLLOW METAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR JOINT JAN LF MAX MECH MFR MIN MSC MTD MTL N/A NIC N NO NOM NTS OC OPNG OPP ORIG PERM PL PLAM PLYWD PNT PR R RB REF REINF REQ'D REV RM RO SCHED 5 SC SECT 5HR SIM SPEC SQ STD STL STOR SUSP TEL TV TYP UCR UNO VCT VERT W W/ W/O WC WD WKST JANITOR LINEAL FOOT MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NORTH NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PERMANENT PLATE PLASTIC LAMINATE PLYWOOD PAINT PAIR RADIUS RUBBER BASE REFRIGERATOR REINFORCING REQUIRED REVISION /REVERSE ROOM ROUGH OPENING SCHEDULE SOUTH SOLID CORE SECTION SHOWER SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TELEPHONE TELEVISION TYPICAL UNDER COUNTER REFRIGERATOR UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL WEST WITH WITHOUT WALLCOVERING WOOD WORK STATION SYMBOL LEGEND ROOM NUMBER DOOR NUMBER DETAIL REFERENCE BUBBLE 0 - ## BASE FINISH SYMBOL WALL FINISH SYMBOL CASEWORK FINISH SYMBOL ELEVATION SYMBOL BREAKLINE SECTION REFERENCE ® KEYNOTE SYMBOL FLOOR FINISH SYMBOL VICINITY MAP • SITE PLAN 1 111111111111 1110111111111111111 � DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON 981 SEPARATE PERMIT REQUIRED FOR Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. I SCALE: 1 " = 60 " -0" NORTH v � leyvvi6lt, Q,toeitc\eitAuv\ k-kv klc&ts k„ �Iri�� eAn -hre --04k Rnk-- w.vre�t� hay(' twx 4:11/07i It-te etc, arced c,c(A-vivl :t 1■ =. KEY PLAN AREA OF WORK CIS GROUP 3,007 5F OF OFFICE 871 SF OF CORRIDOR • • • • • • • ■ • • • • r • PROJECT SCALE: 1/32" = I' -0" NORTH NORTH EGRESS PLAN OCCUPANT LOAD CALCULATION 3,007 5F (OFFICE) x 100 5F PER OCCUPANT = 30.07 OCCUPANTS I EXIT REQUIRED, 2 EXITS PROVIDED COMMON PATH OF EGRESS TRAVEL (38') POINT WHERE MULTIPLE EXITS PATHS ARE AVAILABLE. TRAVEL DISTANCE (88' = 38' +50')- PROJECT SCALE: 1 / 1 = 1 ' -0" NORTH SHEET INDEX IA -0.0 IA-0. I IA -0.2 IA -1.I IA -1.2 IA -I.3 IA -2.1 COVER SHEET SPECIFICATIONS SPECIFICATIONS, CONT. FLOOR PLAN, POWER/ COMMUNICATION PLAN REFLECTED CEILING PLAN FINISH PLAN, FINISH SCHEDULE AND FURNITURE PLAN WALL DETAILS, CASEWORK ELEVATIONS AND DETAILS PROJECT SCOPE PARTIAL FLOOR TENANT IMPROVEMENT ON THE THIRD FLOOR TO INCLUDE CONSTRUCTION OF PARTITIONS, DOORS, CASEWORK, CEILINGS, FINISHES AND OTHER FEATURES. CC)DE INFORMATION ZONING: MIC /L, C /LI, LDR CONSTRUCTION TYPE: I FIRE PROTECTION: OCCUPANCY AREA OF WORK: APPLICABLE CODES: DEFERRED SUBMITTALS: FIRE SPRINKLERS HVAC ELECTRICAL PLUMBING LEGAL DESCRIPTION AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT B (OFFICE) 3,878 SF IBC, 2006 EDITION IFC, 200G EDITION UPC, 2006 EDITION WSEC, 2006 EDITION AMERICAN NATIONAL STANDARD ICC / ANSI AI I 7.1, 2003 EDITION APN: 102304- 9084 -07, 1 02304 - 9080 -0 I , 734060- 0602 -03 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 2 2009 .Pty City oflkwila BUILDING DIVISION LOT G OF TUKWILA BLA #L03 -034 REC #20030725900003 LOCATED IN SE 1/4 OF SEC 9 * SW 1/4 1 0 I N 23 -04. LOT 7 OF TUKWILA BLA #L04 -060 REC #2004 1 008900012 LOCATED IN SE 1/4 OF SEC 9 $ SW 1/4 I O IN. RIVERSIDE INTERURBAN TRS LOT 8 OF TUKWILA BLA L02 -057 REC #20030327900002 LOCATED IN SE 1/4 OF SEC 9 - SW 1/4 I 0 IN 23 -04. FILE COPY Permit tla,, D° X' - Plan review approval issubjedto errors at rlot Arom! of dxl Lion doamel does the violation stmcd° pbedcodeo� on m ma t � ►, , � , .: iSe�dlQloelectg � gy, W1"-- GU Dd /.../e9c)q City Of ?t�kwIIa BUILDING DIV SION PROJECT TEAM PROPERTY OWNER: SABEY CORPORATION 1 2201 TUKWILA INTERNATIONAL BLVD., SUITE 400 SEATTLE, WA 98168 206- 281 -8700 (PHONE) 206 - 281 -0920 (FAX) CONTACT: SANDRA SUSKIC EMAIL: SANDRAS @SABEY.COM ARCHITECT: GENERAL CONTRACTOR: HAZELRIGS ARCHITECTURE $ DESIGN, pllc 26826 5700 CORSON AVE. 5. SEATTLE, WA 98 108 206 - 957 -061 I (PHONE) 253 - 957 -0612 (FAX) CONTACT: COLLEEN HAZELRIGS EMAIL: COLLEEN @HAZELRIGSARCHITECTURE.COM SABEY CONSTRUCTION 1 2201 TUKWILA INTERNATIONAL BLVD., SUITE 400 SEATTLE, WA 98 68 RECEIVED 206 - 281 -4200 (PHONE) CITY OF TUKIMLA 206 - 281 -0920 (FAX) CONTACT: GLENN PARRY EMAIL: GLENNP @SABEY.COM APR 2'2 2009 PERMIT CENTER I)01—cte2. N 0 ti LO 0) c0 0 c0 I E 0 U 0 0 N REGISTERED ARCHITECT 0 a 0 w U) a) z o 0 w 0 c z 4 w z m 0 F w w w > / ' w 7 0 w 0 0 0 0 Checked by Chh Drawn by GG Scale AS NOTED Date 10/17/08 Job No. 08:005 SHEET NUMBER IA -0.0 © 2009 HAD OUTLINE SPECIFICATIONS DIVISION 01 - GENERAL REQUIREMENTS 01 I 0 00 - SUMMARY OF WORK I . GENERAL DESCRIPTION OF THE PROJECT: NON - STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE, UNO. 2. PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD AND TENANT PRIOR TO COMMENCEMENT OF WORK. 3. PROVIDE WORK AND MATERIALS IN ACCORDANCE WITH APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. IN CASE OF CONFLICT WHERE THE METHODS OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES ARE TO GOVERN. NOTIFY ARCHITECT OF CONFLICTS. 4. OBTAIN PERMITS AND APPROVALS REQUIRED. 5. WORK I5 GOVERNED BY CONDITIONS AS INDICATED IN CONTRACT DRAWINGS AND SPECIFICATIONS. 6. DRAWINGS AND SPECIFICATIONS: STRUCTURAL, PLUMBING MECHANICAL, ELECTRICAL, FIRE PROTECTION, AUDIO VISUAL AND CABLING DRAWINGS ARE SUPPLEMENTARY TO THESE DRAWINGS. NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN THE CONSULTANTS' DRAWINGS WITH A WRITTEN REQUEST FOR CLARIFICATION. WORK INSTALLED IN CONFLICT WITH THESE DRAWINGS OR SPECIFICATIONS IS TO BE CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO THE OWNER, TENANT, OR ARCHITECT. 7. DO NOT SCALE DRAWINGS: USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY ARCHITECT OF DISCREPANCIES. DEVIATIONS FROM DIMENSIONED LOCATIONS REQUIRE ARCHITECT APPROVAL. 8. DIMENSIONS ARE TYPICALLY TO THE CENTERLINE OF COLUMNS AND FINISHED FACE OF PARTIONS. U.N.O. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS ARE TO BE 6" FROM THE FACE OF THE ADJACENT PARTION. 9. B/5 INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD. 10. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS "BUILDING STANDARD" ON THE PLANS, ADVISE ARCHITECT WITHIN TEN (10) DAYS OF RECEIPT OF THE PLANS 50 ALTERNATE SELECTIONS MAY BE MADE. 1 I . "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLAN. OFFSET STUDS WHERE REQUIRED TO ASSURE FLUSH WALLS AT COLUMNS. 12. PROVIDE 3 SETRS OF SUBMITTALS TO ARCHITECT; ONE FOR ARCHITECT ONE FOR GENERAL CONTRACTOR AND ONE FOR TRADE. 13. LEVEL EXISTING CONCRETE FLOOR SLAB AS REQUIRED FOR INSTALLATION OF PARTITIONS, DOORS, EQUIPMENT AND FLOOR COVERINGS. 14. MATERIALS USED IN CONSTRUCTION ARE TO MEET CURRENT FLAME CODE REGULATIONS. 15. MATERIALS: MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT ARE TO BE APPLIED AS RECOMMENDED BY MANUFACTURERS. LIKE MATERIALS USED ARE TO BE OF THE SAME MANUFACTURER AND QUALITY UNO. 16. REPAIR DAMAGE TO ADJACENT WORK AT CONTRACTOR'S EXPENSE. 17. COORDINATION: VERIFY AND COORDINATE THE WORK OF TRADES TO ASSURE COMPLIANCE WITH THE DRAWINGS AND SPECIFICATIONS AND FOR DORE DRILLS AND OTHER SLABWORK. 18. INVESTIGATE AND VERIFY LOCATIONS OF STRUCTURAL, MECHANICAL, AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS PRIOR TO BEGINNING THE WORK. 19. LAY OUT THE WORK TO CONFORM TO THE REQUIREMENTS OF CONTRACT DOCUMENTS. ESTABLISH AND MAINTAIN LINES AND DIMENSIONS. BEFORE DOING THE WORK, VERIFY MEASUREMENTS AND CONDITIONS AT THE SITE AND NOTIFY THE ARCHITECTS OF DISCREPANCIES. 20. NOTIFY ARCHITECT, IF INFORMATION IN THE DRAWINGS ARE INCOMPLETE OR IN CONFLICT, FOR CLARIFICATION. 2 I . PENETRATIONS FOR ELEC /MECH /COMMUNICATON PIPING ARE TO BE FULLY PACKED AND SEALED IN ACCORDANCE WITH THE APPLICABLE BUILDING AND FIRE CODES. 22. VERIFY REQUIREMENTS OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES. PROVIDE ROUGH -IN CONNECTIONS. 23. FIRE -STOP PENETRATIONS WITH APPROVED THROUGH PENETRATION FIRE STOP ASSEMBLIES. FIRE STOP RATING TO CORRESPOND WITH RATING OF ASSEMBLIES AS REQUIRED PER CODE. 24. SPRINKLER, HVAC, MECHANICAL, AND ELECTRICAL ARE UNDER SEPARATE PERMIT. ELECTRICAL AND MECHANICAL SUBCONTRACTORS ARE TO OBTAIN APPLICABLE PERMITS AND COMPLY WITH APPLICABLE CODES. VERIFY REQUIREMENTS OF BUILDING SHELL STANDARDS AND TENANT REQUIREMENTS. SHOP DRAWING REVIEW OF THESE TRADES I5 FOR AESTHETIC PURPOSE. 25. PROVIDE FIRE/EMERGENCY SYSTEMS AS REQUIRED BY APPLICABLE CODES. FIRE/EMERGENCY SYSTEMS INCLUDE BUT STROBES, AND SPRINKLERS, SMOKE AND HEAT rETECTORS. AND EXIT SIGNS. 26. SEE "SEATTLE WA DISTRICT DIRECTOR OFFICE SPECIAL REQUIREMENTS / SPECIFIC ROOM REQUIREMENTS, 4/11/08" FOR DETAILED SPACE REQUIREMENTS. 01 14 00 - WORK RESTRICTIONS I . VERIFY CONSTRUCTION REQUIREMENTS AND CONSTRUCTION ADMINISTRATION RESPONSIBILITIES WITH BUILDING MANAGER. VERIFY BUILDING CONSTRUCTION RULES WITH BUILDING MANAGEMENT. 2. MAINTAIN A CLEAR AND UNOBSTRUCTED PATH TO EXITS. 01 25 00 - SUBSTITUTION PROCEDURES I . SUBMIT MATERIAL SUBSTITUTIONS TO ARCHITECT DURING BID PROCESS. 01 64 00 - OWNER-FURNISHED PRODUCTS I. CONFIRM WITH TENANT, TENANT SUPPLIED ITMES AND SYSTEMS, INCLUDING BUT NOT LIMMITED TO DATA CABLING, INTRUSION DETECTION AND VIDEO SURVEILLANCE. 01 71 23 - ACCEPTANCE OF CONDITIONS I. VISIT JOB SITE AND VERIFY FIELD DIMENSIONS AND CONDITIONS AND NOTIFY ARCHITECT OF DISCREPANCIES BEFORE PROCEEDING WITH WORK. 01 74 00 - CLEANING AND WASTE MANAGEMENT I . MAINTAIN THE WORKSPACE IN A CLEAN AND WORKMAN -LIKE MANNER. REMOVE WASTE REGULARLY AND DISPOSE INTO CONSTRUCTION PROVIDED RECEPTACLES. 01 78 00 - CLOSEOUT SUBMITTALS I. PROVIDE 2 COPIES OF OPERATION MANUAL FOR MATERRALS AND SYSTEMS TO BUILDING MANAGER PRIOR TO FINAL PAYMENT. CONFIRM REQUIREMENTS WITH BUILDING MANAGER. DIVISION 02 - EXISTING CONDITIONS I . EXISTING CONDITIONS SHOWN ON THE DRAWINGS ARE GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE WORK. 2. REFER TO SHELL AND CORE RECORD DOCUMENTS FOR INFORMATION RELATED TO CORE CONSTRUCTION FEATURES. I.E., STAIRWELLS, SHOWERS AND JANITOR/ELECTRICAL ROOMS. 3. VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH MATERIAL TO MEET CURRENT FLAME SPREAD REGULATIONS. PREPARE LOCATIONS TO RECEIVE NEW FLOOR FINISH AS REQUIRED. LEAVE FLOOR FLUSH. 21 41 00 DEMOLITION 1. COMPLY WITH RULES AND REGULATIONS OF GOVERNMENTAL AUTHORITIES HAVING JURISDICTION OVER DEMOLITION WORK. 2. SURVEY THE SITE OF PROPOSED WORK TO DETERMINE THE EXTENT AND NATURE OF THE DEMnLITInNI WrIPK PRIOR TO LIRMITTING BI�1 CONT. 21 41 00 - DEMOLITION 3. SUBMIT PROPOSED METHODS AND OPERATION OF DEMOLITION TO OWNER FOR REVIEW PRIOR TO START OF WORK. INCLUDE, IN SCHEDULE, COORDINATION FOR SHUT -OFF, CAPPING AND CONTINUATION OF UTILITY SERVICES AS REQUIRED. COORDINATE WITH BUILDING MANAGEMENT FOR REGULATIONS INCLUDING, BUT NOT LIMITED TO, ELEVATOR USE, RUBBISH REMOVAL, PROTECTION OF BASE BUILDING CONSTRUCTION AND WORK WHICH WILL AFFECT OTHER TENANTS OR OTHER PARTS OF THE BUILDING. 4. PROVIDE NECESSARY SAFE - GUARDS, BARRIERS, TEMPORATY POWER, LIGHTING, FIRE PROTECTION, ETC., AS REQUIRED DURING DEMOLITION. THIS INCLUDES, BUT IS NOT LIMITED TO, KEEPING THE STAIRWAYS AND EXITS UNOBSTRUCTED AND AVAILABLE FOR USE DURING DEMOLITION. 5. REUSE BUILDING MATERIALS SUCH AS, BUT NOT LIMITED TO, DOORS AND FRAMES, HARDWARE, ELECTRIC AND TELEPHONE RECEPTACLES, DIFFUSERS, SPEAKERS, EXIT SIGNS, LIGHT FIXTURES, MECHANICAL FIXTURES, AND PLUMBING FIXTURES WHERE POSSIBLE, UNLESS INDICATED OTHERWISE BY THE OWNER. 6. PROTECT AREA AND NEW OR EXISTING MATERIALS AND FINISHES FROM DAMAGE FROM CONSTUCTION, DUST, WATER, ETC. DAMAGE TO EXISTING MATERIALS, FINISHES, STRUCTURE AND EQUIPMENT IS TO BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE TENANT AND BUILDING OWNER. 7. DISCONNECT POWER IN THE AREA OF WORK PRIOR TO COMMENCEMENT OF DEMOLITION AND PROVIDE TEMPORARY POWER AND LIGHTING FOR DEMOLITION. DISCONNECT ELECTRICAL ITEMS TO BE PERMANENTLY REMOVED AT THE CIRCUIT PANELS. 8. FURNISH LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF DEMOLITION WORK, AREA SHALL BE LEFT BROOM CLEAN. 9. DEMOLITION OF TELEPHONES, ELECTRICAL, VOICE/DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED CABLING TO BE REMOVED FROM TENANT SPACES BELOW. 10. DURING THE REMOVAL OF ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. 11. REMOVE OR RELOCATE EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION AS REQUIRED. 12. DAMAGED, ALTERED OR REWORKED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH ". 13. PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUST AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. DIVISION 03 - CONCRETE NOT USED DIVISION 04 - MASONRY NOT USED DIVISION 05 - METALS NOT USED v on DIVISION 06 - WOOD, PLASTICS AND COMPOSITES 06 I 0 00 - ROUGH CARPENTRY I. ROUGH CARPENTRY TO INCLUDE WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS, BUCKS, NAILERS, BACKING, FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. 06 20 00 - FINISH CARPENTRY 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 06 22 00 - MILLWORK 1. VERIFY CASEWORK DIMENSIONS IN FIELD. 2. CABINET CONSTRUCTION: COMPLY WITH THE A.W.I. ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR CUSTOM GRADE WORK. CABINETS SHALL BE FLUSH CONSTRUCTION. 3. PROVIDE PARTICLE BOARD, MED. DENSITY, WEIGHING <40 LB. /CU. FT., AT LEAST 3/4" THICK. 4. CABINET HARDWARE: FULL EXTENSION DRAWER GLIDES, STAINLESS STEEL CABINET PULLS, US32D FINISH, AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, UNO IN ELEVATIONS / DETAILS, OR PER BUILDING STANDARD. 5. PLASTIC LAMINATE: HIGH - PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, AND FORMICA, UNO. LAMINATE TO BE GENERAL - PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL. 6. OPEN CASEWORK I5 TO BE PLASTIC LAMINATE ON EXPOSED SURFACES, UNO. APPLY MELAMINE TO INTERIOR OF CABINETRY WITH DOORS AND DRAWERS, UNO. 7. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. DIVISION 07 - THERMAL AND MOISTURE PROTECTION NOT USED DIVISION 08 - OPENINGS I. EXIT DOORS ARE TO BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT, AND EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED. 08 12 00 - METAL FRAMES I . PROVIDE DOOR AND RELITE METAL FRAMES PER DRAWINGS. 08 14 00 - WOOD DOORS I. PRE - MACHINE DOORS FOR HARDWARE PER HARDWARE SCHEDULE. 2. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 3. REVIEW SUITE FOR DOOR STYLE CHANGES AND VERIFY WITH ARCHITECT AND BUILDING MANAGEMENT THE DOOR STYLE TO MATCH IF A VARIATION I5 PRESENT. 08 41 13 - ALUMINUM - FRAMED ENTRANCES AND STOREFRONTS I. PROVIDE ALUMINUM STOREFRONT ENTRY PER DRAWINGS. 08 71 00 - DOOR HARDWARE I. PROVIDE COMPLETE COMMERCIAL GRADE FINISH HARDWARE AND SUITABLE FASTENINGS FOR THE PROJECT. PROVIDE POWER AS REQUIRED TO SYSTEMS REQUIRING POWER. 2. MATCH 8/5 STYLE, FINISH AND QUALITY OF SPECIFIED IN SIMILAR LOCATIONS. 3. HARDWARE FURNISHED IN THIS SECTION I5 TO COMPLY WITH THE REQUIREMENTS OF APPLICABLE CODES. ITEMS SPECIFIED IN THIS SECTION ARE TO BE FURNISHED BY A FACTORY DIRECT AUTHORIZED DISTRIBUTOR MAINTAINING LOCAL PARTS, STOCKS AND SERVICES FOR STANDARD SPECIFIED ITEMS. 4. PROVIDE HARDWARE WHICH COMPLIES WITH WASHINGTON STATE AND LOCAL DISABILITY CODES, INCLUDING THE ANSI A117.1-2003 AND WASHINGTON STATE IBC SUPPLEMENTS CURRENTLY IN EFFECT. • 5. PROVIDE LEVER HANDLE LOCK SETS COMMERCIAL GRADE MORTISE -TYPE TO MATCH BUILDING STANDARD, UNLESS NOTED OTHERWISE. PROVIDE ELECTRIC MORTISE LOCK DEVICES AT DOORS W/ CARD READER, DELAY PUSH TO EXIT FUNCTION AND PUSH TO ENTER FUNCTION. 6. SPECIAL LOCKING HARDWARE (CIPHER, KEYCARD, ETC.) MUST COMPLY WITH FPA 101 , 5 -2.1.6 AND BE OPERABLE WITH NO MORE THAN ONE RELEASING OPERATION FROM THE DIRECTION OF EGRESS. 7. CARD READER SYSTEM TO BE PROVIDED BY SEPARATE CONTRACT W/ THE GOVERNMENT. CONTRACTOR TO PROVIDE ELECTRICAL POWER, BACKBOXES AND CONDUIT TO CEILING FOR CARD READERS. 8. PROVIDE SEVEN -PIN RESTRICTED KEYWAY CYLINDER LOCKS ON OFFICE SUITE ENTRY DOORS. 9. PROVIDE ELECTRIC TRANSFER BUTTS AND MAGNETIC SWITCH SETS ON DOORS HAVING AN ACCESS CONTROL SYSTEM READER AND AN ELECTRO- MECHANICAL LATCH OR LOCKSET. CONT. 08 71 00 DOOR HARDWARE 10. 7' -0" HIGH DOORS TO RECEIVE I-1/2 PAIR OF BUTTS, 1 I . DOORS • HAVE 3 SILENCERS, MI 12. SEE DIVISION 28, SECTION 28 13 00 FOR ELECTROMAGNETIC LOCK INFORMATION. 13. NOT USED. rope 4. ARE TO BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE. 15. PROVIDE DOOR STOPS OF APPROPRIATE TYPE EXCEPT WHERE CLOSER LIMITS IMPACT WITH OBSTRUCTION. MATCH ADJACENT HARDWARE. 1 DOOR CLOSERS ARE TO BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES WILL BE 5 SECONDS, MINIMUM. 17. FIRE DOORS ARE TO HAVE THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. 18. THE REQUIRED FORCE FOR PUSHING OR PULLING OPEN DOORS, OTHER THAN FIRE DOORS, IS AS FOLLOWS: INTERIOR HINGED DOOR: 5.0 LB (22.2N) MAXIMUM SLIDING /FOLDING DOOR: 5.0 LB (22.2N) MAXIMUM EXTERIOR HINGED DOOR: 7.5 LB (22.2N) MAXIMUM. 19. LOCK SETS ARE TO CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE TWO (2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. TAG KEYS WITH ROOM NUMBERS. CONFIRM QUANTITY WITH BUILDING MANAGEMENT. 20. SUBMIT HARDWARE WITH CUT SHEETS FOR ARCHITECT REVIEW. 2 I . SET UNITS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND OPERATION. 22. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND DOOR TO ENSURE PROPER OPERATION AND FUNCTION. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHL A I NDED 23. SE "5 A LE A DISTRICT DIRECTOR OFFICE SPECIAL REQUIREMENTS / SPECIFIC ROOM REQUIREMENTS, 4/11/08" FOR SPECIFIC ROOM REQUIREMENTS. 0 DIVISION 09 - FINISHES 08 80 I 0 - GLAZING 1 GLASS IS TO BE CLEAR TEMPERED SAFETY GLASS, UNO. SEE FINISH PLAN * DOOR SCHEDULE. 2. GLASS AT SIDELIGHTS AND DOORS IS TO BE 1/4" TEMPERED SAFETY GLAZING, UNO. 3. VERIFY THAT GLASS THICKNESS I5 APPROPRIATE FOR DIMENSIONS AND SPANS. 4. THIS PROJECT CONTAINS GLAZING THAT IS SUBJECT TO ADHERENCE TO FEDERAL GLAZING STANDARDS. ADVISE ARCHITECT IF INFORMATION IN THE DOCUMENTS 15 NOT IN COMPLIANCE WITH THE STANDARD BEFORE PROCEEDING WITH THE WORK. APPLY FINISHES IN APPLY FINISHES IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 2. SUBMIT SAMPLES OF FINISH COLORS SPECIFIED TO ARCHITECT FOR APPROVAL PRIOR TO BEGINNING WORK. 3. CONFIRM DELIVERY TIMES AND BRING EXCESS LEAD TIMES TO ARCHITECT'S ATTENTION IMMEDIATELY TO ALLOW FOR RE- SPECIFICATION IF NECESSARY. 4. FOLLOW MANUFACTURER PROVIDED DETAILED INSTALLATION GUIDELINES AND USE MANUFACTURER RECOMMENDED ADHESIVE PRODUCT AND TOOLS AS REQUIRED. PROVIDE TENANT /OWNER WITH MANUFACTURER RECOMMENDED CARE AND MAINTENANCE INSTRUCTIONS. 09 29 00 - GYPSUM BOARD I. EXPOSED GWB EDGES ARE TO HAVE METAL EDGE RIM. 2. GWB LEVEL 4 * 5 PARTIONS ARE TO BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. PATCH AND REPAIR SURFACES TO MATCH ADJACENT OR ADJOINING SURFACES WHERE REQUIRED. SURFACES ARE TO BE ALIGNED AND SANDED SMOOTH. OFFSET STUDS WHERE REQUIRED TO ALIGN FINISHED WALL SURFACE. 3. WORK IS TO BE PLUMB, LEVEL, SQUARE AND TRUE, AND IN PROPER ALIGNMENT. 4. STABILIZE CONSTRUCTION AGAINST LATERAL MOVEMENT IN ACCORDANCE WITH THE REQUIREMENTS OF THE LATEST ADOPTED EDITION OF THE INTERNATIONAL BUILDING CODE. MAX. DISTANCE ACCEPTABLE FOR BRACES IS TO BE 12' -0 ". 5. INCLUDE NECESSARY MATERIALS, LABOR AND ACCESSORIES FOR THE INSTALLATION OF PARTITIONS. G. "WALL SURFACES" MEAN VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC. 7. PARTITION HEADS SHALL MATCH BUILDING STANDARD, UNO. 8. INDEPENDENTLY SUPPORT WALLS AND CEILINGS FOR SEISMIC CONDITIONS, IN BUILDING JURISDICTIONS WHERE APPLICABLE. 9. PROVIDE FIRE TREATED WOOD OR EQUIVALENT SHEET METAL BLOCKING REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. 10.. FURR AND FINISH PIPES, CONDUITS, VENTS, ETC. UNLESS NOTED AS EXPOSED ON CONSTRUCTION DRAWINGS. I I . INSULATION MATERIALS, INCLUDING FACINGS SUCH AS VAPOR BARRIERS OR BREATHE PAPERS INSTALLED WITHIN FLOOR - CEILING ASSEMBLIES, WALLS, CRAWL SPACES, OR ATTICS ARE TO HAVE A FLAME - SPREAD RATING NOT TO EXCEED 25 AND A SMOKE DENSITY NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH I.B.C. STANDARDS. 12. FRAMING STUDS: PROVIDE GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE SHEET METAL BACKING WITHIN WALLS RECEIVING CASEWORK (CABINETS, BOOKSHELVES, ETC.). VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCK WHERE APPLICABLE. 13. PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. 14. PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING, AND ELECTRICAL WORK. FIRE RATE AS REQUIRED. 15. DRYWALL TO BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED. PROVIDE "M /R" TYPE DRYWALL WHERE REQUIRED BY CODE AND AT TOILET ROOMS AND BEHIND CERAMIC TILES, UNO. 16. INSTALL CORNER BEADS AT EXTERNAL CORNERS. INSTALL METAL EDGE TRIM WHENEVER EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI - EXPOSED. 17. PRIOR TO RECEIVING FINISH, PROPERLY PREPARED SURFACES AS REQUIRED TO RECEIVE FINAL FINISHING AS SPECIFIED. 18. EXTEND SOFFIT FRAMING TO STRUCTURE ABOVE. PROVIDE DIAGONAL BRACING AS NECESSARY. 19. USE ACOUSTICAL SEALANT AROUND PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES, ETC. ON BOTH SIDES OF CROSSING /PENETRATING WALLS WITH ACOUSTICAL INSULATION. PROTECT PENETRATIONS OF FIRE -RATED WALLS BY APPLICABLE FIRE -RATED ASSEMBLIES. 09 51 00 - ACOUSTICAL CEILINGS I . CEILING HEIGHTS, WHERE INDICATED, ARE FROM CONCRETE FLOOR DECK TO BOTTOM OF CEILING GRID OR OTHER FINISH SURFACE. 2. PROVIDE NEW CEILING TILE, CEILING GRID AND ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEILINGS AS INDICATED ON DRAWINGS. 3. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. VERIFY WITH BUILDING MANAGEMENT IF EXISTING CONDITIONS ARE SEISMICALLY BRACED OR PROVIDE PER CODE. 4. COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEILING AND TENANT CONTRACTORS SUCH AS THE TELEPHONE AND DATA CABLE COMPANIES. 5. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES, REGISTERS, DIFFUSERS, SPRINKLERS, AND OTHER INSERTED ITEMS. 6. CUTOUTS SHALL BE CENTERED WITHIN ACOUSTIC CEILING TILE, UNO. 7. PROVIDE CLASS 1 FLAME SPREAD RATING AND INSTALL MATERIALS IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND CODES. 8. JOINTS IN THE TILE FIELD ARE TO BE SQUARE, LEVEL AND ALIGNED. 9. INSTALLED SUSPENDED CEILINGS LEVEL WITHIN A TOLERANCE OF 1/8" IN 12' -0 ". CONT. 09 51 00 ACOUSTICAL CEILINGS 10. IN AREAS OF ALTERATIONS MATCH CONDITIONS AND ALIGN, LEVEL AND MATCH NEW CEILING TO OLD, AS POSSIBLE. REVIEW CEILINGS UPON COMMENCEMENT OF THE PROJECT AND INFORM THE BUILDING MANAGEMENT OF DISCONTINUITIES IN THE CEILING WITHIN I 0 DAYS. 09 65 00 - RESILIENT FLOORING I. BASE TO BE INSTALLED IN LONGEST AVAILABLE LENGTH WITH NO PIECE LESS THAN 12 ". JOINTS ARE TO BE 6" OR GREATER FORM OUTSIDE CORNERS. 2. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITIOUS UNDERLAY PER MANUFACTURER'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 09 68 00 - CARPETING 1. PREPARE SUB FLOOR WITH LIGHT WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE. MAX. ALLOWABLE TOLERANCE = 1 /4" OVER 10'. 2. PROVIDE SEAMING DIAGRAMS FOR ARCHITECT'S REVIEW FOR BROADLOOOM CARPET. 3. PROVIDE RUBBER REDUCER STRIPS AT LOCATIONS WHERE CARPET AND OTHER FLOORING MEET PER DETAILS. PROVIDE COLOR SAMPLES FOR APPROVAL. 4. INTERSECTIONS OF FLOOR FINISH MATERIALS AT DOORS ARE TO BE LOCATED DIRECTLY UNDER CENTER OF DOOR, UNO. 5. FLOOR COVERINGS IN CLOSETS ARE TO BE THE SAME AS THAT OF THE SPACE INTO WHICH THE CLOSET DOOR OPENS, UNO. 6. PRIOR TO INSTALLATION OF FLOOR FINISHES, PREP AND FLOAT EXISTING SUB -FLOOR TO PREVENT NOTICEABLE LUMPS OR DEPRESSIONS IN FINISHES, AND TO FINISH MANUFACTURER'S RECOMMENDATIONS TO ENSURE MANUFACTURER WARRANTY OF FINISH MATERIAL. 09 91 00 - PAINTING I. APPLY PAINT AND OTHER INTERIOR FINISHING AFTER PROPER PREPARATION TO ENSURE QUALITY AND APPEARANCE OF WORK. 2. UNLESS OTHERWISE NOTED, PRIME GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2) FINISH COATS OF SCHEDULED. 3. PAINTED WOODWORK TO BE FINISHED WITH ONE (I) COAT PRIMER AND TWO (2) FINISH COATS. 4. SEALED WOODWORK TO BE STAINED PER FINISH SCHEDULE AND SEALED WITH COMMERCIAL GRADE CLEAR SATIN VARNISH. 5. LIGHT COLORED PAINT TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -8 "CUSTOM" (2 COAT) GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. 6. DARK COLORED PAINT TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -5 "CUSTOM" (2 COAT) GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES. 7. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME. 8. TOUCH -UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF WORK BY OTHER TRADES. 9. WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY ARE TO RECEIVE THE SAME FINISH AS THE ROOM, UNO. 10. PREPARED PAINTED SURFACES IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (ESPECIALLY IN REGARD TO THE PRIMING OF EXISTING SURFACES). 11. PUTTY NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE APPLYING FINISH. 12. SAND WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. 13. SAND ENAMELED FINISHES APPLIED TO WCODS OR METAL BETWEEN COATS WITH FINE SANDPAPER TO PRODUCE SMOOTH FINISI 14. FINISH WORK IS TO BE UNIFORM AND SMOOTH, FREE OF RUNS, SAGS, DEFECTIVE BRUSHING AND CLOGGING. EDGES OF PAINT ADJOINING OTHER MATERIALS OR COLORS ARE TO BE SHARP AND CLEAN WITHOUT OVERLAPPING. DIVISION 10 - SPECIALTIES NOT USED DIVISION 1 1 - EQUIPMENT NOT USED DIVISION 12 - FURNISHINGS 12 2 100 - WINDOW BLINDS I. BUILDING OWNER PROVIDES BLINDS AT EXTERIOR WINDOWS. 2. CLEAN TO LIKE -NEW CONDITION AND BAG EXISTING MINI BLINDS. 3. PROVIDE SAMPLE AND CUT SHEET OF BLINDS TO ARCHITECT FOR REVIEW. DIVISION 13 - SPECIAL CONSTRUCTION NOT USED DIVISION 14 - CONVEYING EQUIPMENT NOT USED DIVISION 15 -21 - NOT ASSIGNED 5. SPRINKLER HEADS SHALL BE CENTERED IN ACOUSTICAL CEILING TILE, UNO. DIVISION 22 - PLUMBING I. PROVIDE ADEQUATE WALL THICKNESS FOR PLUMBING REGARDLESS OF WALL TYPE INDICATED. 2. PROVIDE SUPPLY, WASTE AND VENT LINES, VALVES, FITTINGS, ETC. REQUIRED FOR KITCHEN SINKS, DISHWASHER, REFRIGERATOR, AIR CONDITIONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER HEATERS, ETC. 3. FIXTURE INSTALLATIONS ARE TO CONFORM TO ACCESSIBILITY CODES. 4. PROVIDE HOT AND COLD WATER TO SINKS /DISHWASHERS. 5. NEW WATER HEATERS ARE TO BE INSTALLED WITH DRIP PAN CONNECTED TO WASTE LINE. REVIEWED F CODE COMPLIANCE APPROVED JUN 0 2 2009 City of Tukwila BUILDING DIVISION i DIVISION 2 I - FIRE SUPPRESSION I . REQUIRED SEMI- RECCESSED FIRE EXTINGUISHER CABINETS ARE TO BE WHITE FACTORY FINISHED BAKED ENAMEL. 2. PROVIDE CLASS 2A FIRE EXTINGUISHERS 3. FIRE EXTINGUISHERS ARE TO BE BY UNDERWRITER'S LABORATORY 2A -1 OBC 5 -LB, MULTIPURPOSE EXTINGUISHER WITH SQUEEZE -TYPE HANDLE AND FLEXIBLE DISCHARGE HOSE WITH VISIBLE PRESSURE GAUGE, UNO. PROVIDE ONE FOR EVERY 6,000 SF AND WITHIN 75 TRAVEL FEET OF OCCUPIED AREAS PER PLANS. CONFIRM LOCATIONS OF FIRE EXTINGUISHERS WITH ARCHITECT. 21 13 00 -.FIRE SUPPRESSION SPRINKLER SYSTEM I . FIRE -STOP PENETRATIONS WITH APPROVED THROUGH PENETRATION FIRE STOP ASSEMBLIES. FIRE STOP RATING TO CORRESPOND WITH RATING OF ASSEMBLIES AS REQUIRED PER CODE. 2. SPRINKLER HEADS WITHOUT DIMENSIONS ARE TO BE CENTERED IN TILE OR COORDINATED WITH CEILING ITEMS UNLESS LANDLORD ALLOWS OTHERWISE. 3. PROVIDE WHITE STROBES ON THE CEILING WHERE REQUIRED. ARCHITECT TO REVIEW AND APPROVE LOCATIONS. 4. PROVIDE CLASS 2A FIRE EXTINGUISHERS FOR EVERY 6,000 SF AND WITHIN 75 TRAVEL FEET OF OCCUPIED AREAS PER PLANS. CONFIRM LOCATIONS OF FIRE EXTINGUISHERS WITH ARCHITECT. DIVISION 23 - HEATING, VENTILATING AND AIR - CONDITIONING 23 30 00 - HVAC AIR DISTRIBUTION I. PROVIDE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF VAV BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY ARCHITECT PRIOR TO INSTALLATION TO INSURE FIELD REVISIONS WILL NOT BE REQUIRED. RECEIVED CITY OF TUKWILA APR 2 2 2009 PERMIT CENTER ea vs; c CS) cm N a eL co U co Crp - L co az r -4 < N 0 ti LO cb N X co L E U 2 U 1 N REGI AR ill( , � A, COLLEEN HAZELRIGS STATE OF WASHINGTON 5714 TERED ITECT CD z C 0 0. 0 N N m 0 0 0 z w Q 0 2 0 1- 0 0 0 0 w J 1- 1- cn z O U o_ 0 Checked by 01 11 Drawn by GG scale AS NOTED Date 10/17/08 Job No. 08 :005 SHEET NUMBER IA -0.1 ANCHOR AS REQUIRED. © 2009 HAD CONT. DIVISION 23 HVAC 2. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH MATERIALS, LABOR AND ACCESSORIES FOR COMPLETE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE HVAC SYSTEM AS REQUIRED. 3. SUBMIT LAYOUT OF HVAC ITEMS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 4. CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS, FILTERS AND THERMOSTATS. 23 40 00 - HVAC AIR CLEANING DEVICES I . PROVIDE FILTERS IN HVAC SUPPLY AND RETURN DURING CONSTRUCTION. REPLACE WITH NEW FILTERS PRIOR TO SUBSTANTIAL COMPLETION. DIVISION 25 - INTEGRATED AUTOMATION NOT USED DIVISION 26 - ELECTRICAL 1. ARCHITECTURAL DRAWINGS INDICATE LOCATION OF DEVICES SHOWN. SWITCHING AND CIRCUITING ARE INDICATED ON SEPARATE ELECTRICAL ENGINEERING OR AS -BUILT DRAWINGS AND ARE TO MEET BUILDING GUIDELINES. 2. OUTLETS AND MUD RINGS TO BE LOCATED AT 18" AFF TO THE CENTER LINE, UNO. 3. DRAWINGS INDICATE EXCEPTIONS TO THE STANDARD DIMENSION TO CENTERLINE OF TELEPHONE, ELECTRICAL, AND COMMUNICATION COVER PLATE. OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION BETWEEN EACH DEVICE. 4. THE CENTERLINE OF ELECTRICAL OUTLETS ARE TO BE G" FROM THE CENTERLINE OF PHONE/DATA OUTLETS WHERE LOCATED TOGETHER. 5. WALL MOUNTED RECEPTACLES LOCATED IN CASEWORK ARE TO BE MOUNTED HORIZONTALLY. G. SPECIAL OUTLET HEIGHTS ARE NOTED ADJACENT TO THE OUTLET. 7. WHERE MULTIPLE DEVICES OCCUR IN A SINGLE LOCATION, DEVICES SHALL BE GANGED UNO. 8. BACK -TO -BACK OUTLETS ARE NOT PERMITTED. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED FOR ACOUSTICAL CONTROL. 9. LOCATION OF WALL MOUNTED POWER AND DATA DEVICES SHALL BE MELD REVIEWED BY THE TENANT BEFORE INSTALLATION. 10. ELECTRICAL ENGINEER TO PROVIDE DESIGN /BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. 1 I . ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES. COORDINATE EXACT LOCATION WITH FURNITURE VENDOR. 12. COORDINATE POWER/DATA, FIRE SAFETY DEVICES * LIGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR ELEVATIONS, SYSTEM FURNITURE, FINISHES * CASEWORK. 13. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER/DATA DEVICES AND LIGHT FIXTURES. COORDINATE WITH INTERIOR FINISHES AND CASEWORK. 14. PROVIDE UNDERWRITERS LABORATAORIES, INC (UL) LADLED DEVICES THROUGHOUT. 15. ARCHITECTURAL DRAWINGS DETERMINE LOCATION AND TYPE (ARCHITECT TO VERIFY WITH ENGINEER) OF OUTLETS AND TAKE PRECEDENCE OVER OTHER DRAWINGS U.N.O. ELECTRICAL ENGINEER'S POWER PLAN GOVERNS THE WIRING LAYOUT AND INSTALLATION IN COMPLIANCE WITH LAWS APPLICABLE AND ENFORCED BY GOVERNING AUTHORITIES. 1 PRIOR TO INSTALLING LIGHT FIXTURES ON THIS PROJECT, FIELD CHECK FOR CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, PIPES, ECT. NOTIFY ARCHITECT OF CONFLICT(S) 50 A NEW LAYOUT CAN BE GENERATED. DO NOT INSTALL LIGHT FIXTURES UNTIL CONFLICTS ARE RESOLVED. 1 ROVIDE EM 'GENC '_THWAY LIGHTING PER CODE. . PROVIDE WHITE ELECTRICA PLATES. U V . -, 0 RD REVIEW. MECHANICAL, FIRE PROTECTION AND OTHER COVER ATION, STACKED TOGETHER AND WITH ARCHITECT AND 19. COORDINATE WORK RELATED TO EQUIPMENT WITH MANUFACTURER'S RECOMMENDATIONS, SPECIFICATIONS AND INSTRUCTIONS. 20. COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE INSTALLATION OF TENANT'S NEW FURNITURE. 2 I . COORDINATE WITH THE TENANT SUPPLIED FURNITURE SYSTEMS. ITMMS SUCH AS ELECTRICAL AND DATA WIRING LOCATIONS, J -BOX LOCATIONS, CONNECTIONS AND WALL MOUNTED REQUIREMENTS. 22. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. REPLACE OUTLET COVER PLATES TO MATCH NEW FINISH IF APPLICABLE. 23. PROVIDE WORK, EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL 5 25. WIRI ' DEVICES ARE TO BE BUILDING STANDARD EXCEPT "ISOLATED GROUND" OUTLETS SHALL BE ORANGE, "HOSPITAL GRADE ISOLATED GROUND" OUTLETS SHALL BE ORANGE WITH A GREEN DOT, "EMERGENCY" OUTLETS SHALL BE RED, AND "DEDICATED" OUTLETS FOR "CLEAN CIRCUIT" FIXTURES SHALL BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). COVER PLATES ARE TO BE BUILDING STANDARD FINISH, UNO. VERIFY WITH BUILDING MANAGEMENT. 26. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING THE TELEPHONE SWITCH, COPIERS, COMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION DOCUMENTS. 27. CONCEAL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING, AND CONDUIT IN FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA IS TO BE PROVIDED BY TENANT A 28. SEE "SEATTLE WA DISTRICT DIRECTOR OFFICE SPECIAL REQUIREMENTS / SPECIFIC ROOM REQUIREMENTS, 4/11/08" FOR SPECIFIC ROOM REQUIREMENTS. 26 50 00 - LIGHTING I . SWITCHES SHALL BE MOUNTED AT A MAXIMUM HE . OF 48' LATEST ACCESSIBILITY CODES AND REGULATION 2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE L GANGED UNO. 3. RE- CIRCUIT AND RE- SWITCH ASPECTS OF TENANT SUITE AND ADJOINING SUITES AS NECESSARY TO FULLY SEPARATE TENANT SUITE FROM OTHERS, AND PROVIDE NEW CORRIDOR HALLWAY AND OPEN OFFICE SWITCHES AS NEEDED. F i AS LESS THAN 300 SQ. FT. ENCLOSED BY WALLS OR CEILING - HEIGHT PARTITIONS, AND MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS, PER CODE. DIVISION 27 - COMMUNICATIONS 27 20 00 - VOICE AND DATA COMMUNICATIONS I . PROVIDE CAT6 CABLE WITH ONE PHONE AND TWO DATA DROPS AT EACH LOCATION INDICATED ON PLANS. 2. CABLE TO BE PLENUM RATED RGG CATV SPECIFIED THOMAS * Bt 115 SNAP AND SEAL CONNECTOR. 3. TERMINATE IN RESPECTIVE PROVIDED SP 4. OR DATA AN Ir CAB ING REF R 0 D•CUMENT "STRUCTURED CABLE PLANT OF WORK 0 FOR SEATTLE WA, DISTRICT FIELD OFFICE IT SERVICE REQUEST NUMBER (IT SR):SEA- DO -V -08 APRIL 4, 2008" 5. FOR COMPUTER AND TELEPHONE SEE "COMPUTER AND TELEPHONE ROOM STANDARDS OFFICE OF INFORMATION TECHNOLOGY IN COLLABORATION WITH OFFICE OF FACILITIES AND SPACE MANAGEMENT, SEPTEMBER 2007." CONT. DIV 28 ELECTRONIC SAFETY & SECURITY DIVISION 28 - ELECTRONIC SAFETY AND SECURITY 28 13 00 - ACCESS CONTROL I . PROVIDE DOOR ACCESS CONTROL PER PLANS. SEE DOOR HARDWARE SECTION FOR ELECTROMAGNETIC LOCKS ARE TO BE THE HEADER SURFACE MOUNT TYPE. FLUSH A (SHEAR) LOCKS ARE NOT TO BE USED. THEY ARE TO HAVE A HOLDING FORCE CERTIFIED AT LEAST 1 500 POUNDS. SELECT MODELS W/ BUILT -IN SENSORS INDICATING DOOR CLOSED, LOCKED AND DOOR FORCED OPEN. STATUS READINGS ARE TO BE VIA THE ALARM CONTROL MONITORING EQUIPMENT OR THROUGH THE USE OF A SEPARATE ELECTRIC LOCK CONSOLE. 3. ELECTROMAGNETIC LOCKS REQUIRE A REQUEST -TO -EXIT (RQE) PRESENCE (MICROWAVE OF PASSIVE INFRARED) SENSOR, RQE HEAVY DUTY BUTTON, OR RQE 'TOUCH SENSITIVE" BAR TO RELEASE THE LOCK IN ORDER TO EXIT, WHEN READERS OR KEYPADS ARE NOT USED ON BOTH SIDES OF THE CONTROL POINT. 4. DOORS WITH PROXIMITY CARD READERS ARE TO BE EQUIPPED WITH DOOR CLOSERS, ELECTRIC STRIKES AND MORTISED STOREROOM FUNCTION DOOR HARDWARE. 5. INTERIOR PROXIMITY CARD READERS ARE TO BE COMPACT AND LOW PROFILE IN DESIGN. DOORS EQUIPPED WITH THIS SYSTEM ARE TO BE FAIL/SECURE. 7. PROVIDE A MINIMUM OF 15 PROGRAMMABLE PROXIMITY CARDS. 8. LOCATE THE SYSTEM IN THE COMPUTER ROOM AND POWER IT BY UPS IN THE EVENT OF A LOSS OF BUILDING POWER. 9. PROVIDE COMPUTER, MONITOR, PRINTER AND NECESSARY HARDWARE AND SOFTWARE FORA COMPLETE INSTALLATION. 1. ADDITIO IN &TI 28 16 00 - INTRUSION DETECTION PROVIDE COMPLETE SYSTEM WITH COMPUTER HARDWARE, SOFTWARE AND PRINTERS. 2. SYSTEMS IS TO BE ACTIVE FROM 5:30 PMP TO 6:45 AM MONDAY THROUGH FRIDAY AND 5:30 PM FRIDAY TO 6:45 AM MONDAY. 3. SYSTEM IS TO BE ACTIVE 24 HOUR/DAY ON FEDERAL HOLIDAYS. 4. SYSTEM IS TO BE PROGRAMMABLE TO CHANGE ACTIVE HOURS. 5. PROVIDE SYSTEM AT EXTERIOR WINDOWS USING MAGNETIC SWITCHES, MOTION SENSORS OR ULTRASONIC SENSORS G. PROVIDE UNITERRUPTED POWER SOURCE 7. SYSTEM 15 TO NOTIFY DENVER FEDERAL PROTECTIVE SERVICE MEGACENTER AT I -800 487 -4 1 58 WHEN ALARM IS TRIGGERED. 8. SYSTEM 15 TO ACTIVATE AN AUDIBLE ALARM OUTSIDE BUILDING 9. ALARM LINES ARE TO BE IN CONDUIT FORM THE ALARM BOX TO TELEPHONE JUNCTION BOX. 10. SYSTEM 15 TO BE EQUIPPED WITH HIGH SECURITY LINE PROTECTION AND ZONED TO PROVIDE CONTINUOUS PROTECTION 28 23 00 - VIDEO SURVEILLANCE I . PROVIDE VIDEO SURVEILLANCE AT WAITING AREAS. TYPES OF CAMERAS PER PRIOR DESIGN. LOCATION PER TENANT. 2. VIDEO MONITORING I5 TO BE AT PRIOR DETERMINED LOCATION SEPARATE FROM TENANT BUILD -OUT. 28 3 100 - FIRE DETECTION AND ALARM I . PROVIDE AUDIBLE AND VISUAL ALARMS PER CODE. 2. PROVIDE WHITE STROBES ON THE CEILING WHERE REQUIRED. ARCHITECT TO REVIEW AND APPROVE LOCATIONS. 3. ALTER OR INSTALL FIRE PROTECTION SYSTEM PER BUILDING STANDARD, LOCAL REGULATIONS AND ORDINANCES. 4. PROVIDE EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS REQUIRED BY CODE. DESIGN AND INSTALL IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT. 5. SUBMIT LAYOUT OF ITEMS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE HORNS AND STROBES. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 2 2009 City of Tukwila BUILDING DIVISION r.) 0 01 serw0(pa RECEIVED CITY OF TUKWILA APR 2`2 2009 PERMIT CENTER 9 ti LO Cn Co O CV 0 0 CL CV • C0 LC) 0 ti 0) CO 0 CV E U 0 0 N C13 0 • COLLEEN HAZELRIGS .STATE OF WASHINGTON 5714 REGISTERED ARC ITECT CI) z 0 Ea w cc 0 0. 0 a) 0 m a) 0 0 z a w Q m 0 11 UI- w o ca 0 -3 z O >> > wz z � 2o z I- OI- <u_ I-�- O u cr O E w'• tD O F-F-cci-zz cc cc -J O « : oh w L Q N ` Q U LJ Q c1) - Cn z 0 0 0 0 w J 1- 1- I-- z O U z 0 U_ LL U w 0 CD w Q 0 0 0 cc 0 0 Checked by CHH Drawn by GG Scale AS NOTED Date 10/ 1 7/08 Job No. 08:005 SHEET NUMBER IA -0.2 © 2009I1AD A RCP LEGEND 5/5 "SECOND LOOK" ACOUSTICAL CEILING TILE AND ON B/5 2'x4' CEILING GRID @ 9' -0" AFF (CONFIRM WITH CEILING @ SECOND FLOOR AND MATCH). NEW WITH - LAMP T -8 2'x4' FLUORESCENT LIGHT FIXTURE EQUIPPED IMMER. LAMP COLOR 3500 K. - LAMP T -8 2'x4' FLUORESCENT NIGHT LIGHT FIXTURE. NEW B/5 EXIT SIGN. NEW 13/S TOGGLE SWITCH. e NEW 5 /SEXH -- AN LIGHTING CALCULATION - OFFICE WATTAGE ALLOWED: 3,007 SF x 1 .0 WATT PER SF = 3,007 WATTS CONCLUSION: WATTAGE PROPOSED IS LESS THAN WATTAGE ALLOWED. WATTAGE ALLOWED: 871 SF x 0.8 WATT PER 5F = 697 WATTS CONCLUSION: WATTAGE PROPOSED IS LESS THAN WATTAGE ALLOWED. WATTAGE PROPOSED: (44) 2'x4' LIGHT FIXTURES x 64 WATTS PER FIXTURE = 2,816 WATTS LIGHTING CALCULATION - CORRIDOR WATTAGE PROPOSED: (8) 2'x4' LIGHT FIXTURES x 64 WATTS PER FIXTURE = 512 WATTS REFLECTED CEILING PLAN KEYNOTES 0 NOT USED 0 SWITCH LIGHTS WITHIN 15' OF WINDOWS SEPARATELY PER NON RESIDENTIAL ENERGY CODE. ALIGN NEW GRID TO EXISTING CORRIDOR GRID. 4 CONFERENCE ROOM SEPARATE THERMOSTAT - NO OTHER SPACES D O WITH SEPARATE THERMOSTAT. \'M\ ■ ■ ■I —a ■■■ \►\11■■Eammo . MMEWEIMPAIMMEMEL ■ ■.mam ■ ■ \m!! ■■II FILES I • •I 1111111■ uI COMPUTER ROOM 3' -1 I 1/4" OFFICE OFFICE J r EQ OFFICE BREAK VESTIBULE ELECTRICAL 1 351 1 1 353 1 EQ OPEN WORK AREA 1 CONFERENCE OFFICE REFLECTED CEILING PLAN 1/8" = I ' - 0" NORTH 5' I0' REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 2 2009 City of Tukwila DIVI,Rinhi 20' RECEIVED CITY OF TUKWILA PR 22 2009 PERMIT CENTER 30' Lid bLD f `D cu c a) ca a R3 5714 REGISTERED ARCHITECT COLLEEN HAZELRIGS STATE OF WASHINGTON g)-v1), z 0 O 0. U N N 0 m 0 0 z z 0 0 0 0 J I- 1- z a z J W U 0 w U w J W 0 0 cc 0 0 Checked by CH H Drawn by GG Scale AS NOTED Date 10/17/08 Job No. 08:005 SHEET NUMBER IA -1.2 © 2009 HAD FINISH SCHEDULE SYMBOL DESCRIPTION MANUFACTURER STYLE COLOR/FINISH INSTALLATION SIZE CONTACT NOTL5 NOT USED Q NOT USED LINOLEUM TILE FORDO MARMOLEUM DUAL TBD GLUE DOWN 13" X 13" MARTHA KORSLUND 206- 650 -0597 Q NOTE 2 LT -I LINOLEUM TILE FORGO MARMOLEUM DUAL TBD GLUE DOWN 1 3" X 13" MARTHA KORSLUND 206 -650 -0597 ACCENT, NOTE 2 LT -2 CARPET TILES SHAW 59492 KNIT TBD GLUE STRIP @ 10' BOTH DIRECTIONS 24" X 24" LAURIE STALEY Q 206 - 390 -4246 INSTALLATION PATTERN TBD (SEE NOTES) CPT -I CARPET BROADLOOM SHAW 50895 METRO BL, 28 OZ 95220 IT'S ONLY NATURAL GLUE DOWN 12' W LAURIE STALEY 206 - 390 -4246 COMMON CORRIDOR CPT -2 CARPET BROADLOOM SHAW 50515 UTOPIAN BL, 32 OZ 4371 I CHOCOLATE GLUE DOWN 12' W LAURIE STALEY 206 - 390 -4246 COMMON CORRIDOR - ACCENT CPT -3 0 PAINT BENJAMIN MOORS CLASSIC COLORS TBD /EGGSHELL MEDIUM NAP ROLLER N/A RANDY TESSMAN 800- 642 -5678 NOTE 1 41) PAINT BENJAMIN MOORS CLASSIC COLORS TBD /EGGSHELL MEDIUM NAP ROLLER N/A RANDY TESSMAN 800 - 642 -5678 ACCENT, NOTE I 0 PAINT BENJAMIN MOORS CLASSIC COLORS TBD/ EGGSHELL MEDIUM NAP ROLLER N/A RANDY TESSMAN 800 - 642 -5678 COMMON CORRIDOR, NOTE I RUBBER BASE JOHNSONITE RUBBER TOE BASE (COVED) Q TBD GLUE ON 1/8" X 4" JOHN FERGUSON 253 - 395 -6287 EXT 1 682 OR 800- 345 -6287 WITH CPT- I AND RESILIENT TILE, NOTE 2 B -1 RUBBER BASE JOHNSONITE RUBBER TOE BASE (COVED) TBD GLUE ON 1/8" X 4" JOHN FERGUSON 253 - 395 -6287 EXT 1 682 OR 800 - 345 -6287 WITH CPT -2 NOTE 2 B -2 CO P -LAM WILSONART TBD GLUE ON N/A HAZEL STRICKON 206 - 321 -3294 VERTICAL SURFACES LM-2 P -LAM WILSONART TBD GLUE ON N/A HAZEL STRICKON 206 - 321 -3294 COUNTERTOPS, POST - FORMED EDGES 07) BLINDS LEVOLOR HORIZONTAL TBD CONFIRM W /LANDLORD I " INTERIOR RECITES BL 2 BLINDS LEVOLOR TILTONE HORIZONTAL TBD CONFIRM W /LANDLORD 1" EXTERIOR WINDOWS MO CEILING TILE ARMSTRONG FINE FISSURED 1 824 WHITE (WH) 2' X 4' BRIANNE DEVER 877 -276 -7876, OPTION 8, EXT 4325 SCORED TO SECOND LOOK FINISH NOTES: I . PAINT COLOR I5 FOR MATCH 2. VINYL IS NOT AN ACCEPTABLE SUBSTITUTE. PROVIDE ALTERNATIVES TO VINYL IN THE PROJECT. CONSULT ARCHITECT. 3. ADHESIVE IS TO BE LOW VOC. 4. FLOORS ARE TO RECEIVE CPT- I , UNO. •. 5. WALLS ARE TO RECEIVE P -1, UNO. 1/4 TURN INSTALLATION MONOLITHIC 6. WALL BASE IS TO BE B- I , UNO. INSTALLATION 7. PROVIDE 10% OVERAGE ON CARPET. r■ WW1 T.11 • .. • OFFICE BREAK 1 301 1 RECEPTION ELECTRICAL ALSO COLUMN CORRIDOR FILES THROUGHOUT CORRIDOR OFFICE 1 304 1 FINISH PLAN 1/8" = 1 ' - 0" OFFICE 1 304 1 LT -2 OFFICE 1 305 I ENLARGED KITCHEN FLOORING PLAN OFFICE 1 305 OPEN WORK AREA 1 306 1 NORTh OFFICE BREAK 13O0KCASE$ It DJ IIIIIIRM-1111. MEW MI 1 301 RECEPTION ELECTRICAL CORRIDOR (U 1) e I e ----- i - - - - -� • 1 1 1 1 1 I : •••••■ ■ ■i• 1107.11 017 F OPEN WORK AREA 13061 FURNITURE PLAN — FOR INFORMATION ONLY 1/8" = I ' - 0" CONFERENCE 1 307 1 307 CONFERENCE OFFICE 308 CP - 0Q2 OFFICE 1 308 I NORTh 5' 10' 0 5' I0' NORTh 20' REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 2 2009 City of Tukwila BUILDING DIVISION 20' 30' 30' RECEIVED ITY OF TUKWILA APR 2 2 2009 RMIT CENTER CO 9 ti O CO 0 N c 0 0 ' 5714 REGISTERED ARCH a; " 1 lY COLLEEN HAZELRIGS MATE OF WASHINGTON 0 co cc c 0 0 U) ❑ 0 Z - O) 0 0 z 0 1- cc 0 cc O 0 0 z W z J z = W U CC 0- M rn 1- L LL LL LL 0 0 CC U Checked by CHH Drawn by GG Scale AS NOTED Date 10/ 17/08 Job No. 08:005 SHEET NUMBER IA -1.3 C) 2009 HAD N 17 .1 35" 1/2" = 1 - 0" PROVIDE INSULATION AT SUPPLY $ DRAIN LINES. 24" EACH STEP 1 /8" +31 k ( 2qT CHAIR RAIL DETAIL 18" BREAK ROOM SOUTH ELEV. CHAIR RAIL TYP THIS ROOM COORDINATE HEIGHT WITH US CIS PROJECT MANAGER ACCESSIBLE SINK FAUCET VERIFY THAT " UMBING LINES AND • IXTU RES FIT WITHIN • CLOSURES PRIOR TO P MBING INSTALLATION 4 11 PLYWOOD SUBSTRATE COUNTERTOP - W /SQUARE P -LAM FINISH EDGES FALSE DRAWER ATTACHED TO FACE OF FAC5IA, P -LAM CLAD STAPLE PULLS CONCEALED HINGES GARBAGE DISPOSAL AS SPECIFIED 3/4 " PLYWOOD DOOR SUBSTRATE W/P -LAM FINISH 1 /4 "MDF5ACK CLEAR AREA FOR ACCESSIBILITY 48J CASEWORK DETAIL —SINK 0 1/2= 9 CONFERENCE RM. WEST ELEV. WOOD AND STAIN TO MATCH DOORS LD C1) d N d- m C 3 BREAK ROOM WEST ELEV. 14' } SCALE TITLE 5\\ TITLE J sCALE 16 TITLE 22" /t\ 24" 72" 26" 13" 13" SHELF FOR th MICROWAVE SEE FINISH SCHEDULE FOR P -LAM DESIGNATIONS 5EE DETAIL I /IA -2.1 FOR WALL BRACING. 5/8" GWB OVER 2 1/2" x 25 GA. METAL STUD @ 24" O.C. FILLED WITH SOUND ATTENUATION BAIT INSULATION. 2 1 /2" X 25 GA STL STUD BOTTOM TRACK. FASTEN W /SHOT PIN IN PLASTIC WASHER (NILTI # DS 42 F10, TYP. GLASS 9� PARTITION WALL ALUM SF HEAD /JAMB DETAIL 3"= I' -0" GLASS RUNNER MOUNTED TO WALL ALUMINUM STOREFRONT FRAME 1 ALUM SF FLUSH JAMB DETAIL \J3• - a FLOOR RUNNER ALUMINUM STOREFRONT FRAME 4 d a 'a a a SEE DETAIL 3/IA -2.1 FOR ACT BRACING. 0 CONSTRUCTION PER GA WP 10730R 1 076 TO ACHIEVE STC RATING OF 45 MIN. 2' OF 4" BAIT INSULATION ON BOTH SIDES OF WALL 1/2" a A 2 � ALUM SF SILL DETAIL SHIM CORRIDOR WALL FINISHED FLOOR HOLD GWB AWAY FROM SLAB 1/2" CLG. GRID EDGE TRIM PER DETAIL 3/IA -2. I 5/8" GWB OVER 2 1/2" x 25 GA. METAL STUD @ 24" O.C. FILLED WITH SOUND ATTENUATION GATT INSULATION. C 51 DEMISING WALL City of Tukwila BUILDING DIVISION DOOR HEAD /JAMB DETAIL 3 11 = I ' WALL PER PLAN 311 WALL PER PLAN RECITE SILL CONT. 2 1/2" 20 GA SLIP JOINT TRACK W/ 2 -# 10 SCREWS AT 24" OC. CONSTRUCTION PER GA WP 10730R 1 076 TO ACHIEVE STC RATING OF 45 MIN. 2 1 /2" X 25 GA STL STUD BOTTOM TRACK. FASTEN W /SHOT PIN IN PLASTIC WASHER NILTI # D5 42 P 10, TYP. HM DOOR FRAM E GLASS PER HM DOOR DOOR TYPE FRAME DOOR / RECITE JAMB DETAIL DOOR PER SCHEDULE COD VIEWED FOR COMPLIANCE APPROVED JUN 0 2 2009 DOOR PER SCHEDULE 0 NOTE: i ANGLE: I " X I " X I /2" LONG X .10 THICK (1YP.) N.T.S. FASTEN VERTICAL STRUT FROM MAIN RUNNER TO STRUCTURAL SUPPORT ABOVE HEAVY GAUGE WIRE "PIN ". HEAVY DUTY MAIN RUNNER AT 4' -0" O.C. HEAVY DUTY CROSS RUNNER 1 NSTALLATI ON N.T.S. 4 1 TITLE J sCALE CONCRETE METAL DECK SHOT PIN W/ PLASTIC WASHER (NILT( #DS 42 P 10) (TYP.) #9 WIRE (TYP.) #12X I /2" SCREW BACKING PLATE 2" X 2" X 18 G.A. LATERAL BRACING TENANT WALLS M � TYP "I MAX LATERAL BRACING PER DETAIL ABOVE (TYP.) TYPICAL PARTITION PLAN INSTALL LATERAL BRACING ON PARTITIONS AT 4 T. O.C. TYPICAL PARTITION BRACING 2. WIRE TIES TO HAVE 3 TIGHT TURNS WITHIN 3 ". VERTICAL WIRE HANGER -NO. 12 GAUGE @ 4' -0" O.C. OK N0. 10 GAUGE @ 5' -O" O.C. ALONG MAIN RUNNERS W13 WIRE TURNS. INSTALL WITHIN 1 :6 OUT OF PLUMB UNLESS COUNTER SLOPING WIRES ARE PROVIDED. VERTICAL STRUT @ 12' -0" EACH DIRECTION AND 6' -O" MAX FROM WALL, FASTENED TO MAIN RUNNER AND CUT TIGHT TO STRUCTURE ABOVE, HELD IN CE BY VERTICAL WIRE HANGER AND HEAVY GAUGE WIRE MN. — LATERAL BRACING: SPLAY WIRE ODS. SEE NOTE 1. INSTALL PER ASTM C 636, STANDARD PRACTICE FOR INSTALLATION OF METAL CEILING SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY -IN PANELS. SUSPENDED CEILING SUPPORT DATA. 1. LATERAL SUPPORT SHALL BE PROVIDED BY FOUR WIRES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS, 90 DEGREES APART AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORTS SHALL BE PLACED 1 2' -0" O.C. IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' -O" FROM EACH WALL. 3. PROVIDE 2" MIN WIDTH PERIMETER SUPPORTING CLOSURE WALL ANGLE. 4. ATTACH GRID TO THE WALL ANGLE AT TWO ADJACENT SIDES, POP RIVETS ACCEPTABLE. AT OTHER SIDES PROVIDE 3/4" CLEAR BETWEEN END OF GRID AND WALL. 5. PROVIDE STABILIZER BAR TO PREVENT SPREAD OF MAIN BEAMS AND CROSS TEES. 6. PROVIDE PERIMETER SUPPORT (TAIL) WIRES WITHIN 8" OF WALL EDGES. 7. PROVIDE SEISMIC JOINT TO LIMIT UNINTERRUPTED CEILING SYSTEMS TO 2,500 Sr. 8. PROVIDE POSITIVE BRACING AT CEILING PLANE CHANGES. 9. SUPPORT CABLE TRAYS AND ELECTRICAL CONDUIT INDEPENDENTLY OF CEILING. 10. FOR CEILINGS WITHOUT RIGID BRACING PROVIDE 2" OVERSIZE RING, SLEEVE OR ADAPTOR THROUGH TILE TO ALLOW FREE MOVEMENT OF AT LEAST 1 " IN ALL HORIZONTAL DIRECTIONS, OR PROVIDE SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT THAT PROVIDES THE 1 " HORIZONTAL MOVEMENT REQUIRED. SUSPENDED CL. SUPPORT DATA RECEIVED CITY OF TUKWILA APR 2' 2 2009 PERMIT CENTER 0) z O W w Q m 0 c D) . a) . C ca rn c a) L U a) U L r� COLLEEN HAZELRIGS STATE OF WASHINGTON c O 0. N 0 m 0 5714 a a Checked by CHH Drawn by GG SHEET NUMBER REGISTERED ARCHITECT s s U m 0 0 m O 4 O o rn a) m O I— wv Cn W 0 —, rr z o 0 J :oco zwz Q� I-- 0 I— W zIm1: Z �, Q u o: O wO � F— I—p:Uzz : 0 ;5 < O « h cDF � fti cD WCjW UDQtnT -cn Scale AS NOTED Date 10/ 17/08 Job No. 08:005 r (0 O ti 9) (0 0 N c 0 0_ i w Q 0 w Q 0 IA -2.1 © 200911AD U ai L U 0 0 0) N ca 2