Loading...
HomeMy WebLinkAboutPermit D09-067 - BADAR GROCERY & PIZZA - CHANGE OF USEBADAR GROCERY & PIZZA 3920 S 146 ST D09 -067 Parcel No.: 0040000254 Address: 3920 S 146 ST TUKW Suite No: Tenant: Name: RADAR GROCERY & PIZZA Address: 3920 S 146 ST, #B , TUKWILA WA Owner: Name: POLL TUKWILA LLC Address: 8915 SE 44TH ST , MERCER ISLAND WA 98040 Phone: Contact Person: Name: LARRY GRIFFIN Address: PO BOX 22196 , SEATTLE WA 98122 Phone: 206 909 -7552 Contractor: Name: ALL CITY PLUMB & HVAC LLC Address: 6197 118 AV SE , BELLEVUE WA 98006 Phone: 206 255 -4271 Contractor License No: ALLCICP935MU Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 Citylif Tukwila �1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us $1,500.00 DEVELOPMENT PERMIT * * continued on next page ** Permit Number: D09 -067 Issue Date: 06/11/2009 Permit Expires On: 12/08/2009 Expiration Date: 07/31/2009 DESCRIPTION OF WORK: FORMAL CHANGE OF USE TO FAST FOOD. INSTALL TYPE I HOOD IN EXISTING COMMERCIAL KITCHEN (SEPARATE MECHANICAL PERMIT) RESULTING IN ROOF PENETRATION. BUILD /FRAME 10' X 10' OFFICE SPACE. PROJECT IN VALLEY VIEW SEWER DISTRICT. Fees Collected: $169.50 International Building Code Edition: 2006 Occupancy per IBC: 0004 D09 -067 Printed: 06 -11 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied The granting of this permit does not pre construction or the ormance of work. Signature: Print Name: doc: IBC -10/06 City oikukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N sTe . &( c( 4 Volumes: Cut 0 c.y. Permit Number: Issue Date: Permit Expires On: Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non - Profit: N Public: DO9 -067 06/11/2009 12/08/2009 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit. Date: (�/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -067 Printed: 06 -11 -2009 Parcel No.: 0040000254 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 3920 S 146 ST TUKW • City of Tukwila BADAR GROCERY & PIZZA 13: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS • Permit Number: Status: Applied Date: Issue Date: D09 -067 ISSUED 04/27/2009 06/11/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: AU mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: All food preparation establishments must have Seattle /King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle /King County Department of Public Health, (206/296- 4928), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. D09 -067 Printed: 06 -11 -2009 14: Per May 29, 2009 Valley View letter it was determined that a properly maintained bio- enzyme greaase control systemm will be adequate for the Pizza Resttaurant. Prior to final Public Works permit sign -off the applicant shall contact Mr. Dana Dick, Valley View Sewer District General Manager at (206) 242 -3236 to confirm proper installation of the bio - enzyme system. 15: ** *FIRE DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with doc: Cond -10/06 D09 -067 Printed: 06 -11 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 29: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 31: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 32: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 33: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 34: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 36: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 37: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 38: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 39: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 40: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 41: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: Cond -10/06 D09 -067 Printed: 06 -11 -2009 doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 42: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * * continued on next page ** D09 -067 Printed: 06 -11 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: 14c e Ss D doc: Cond -10/06 D09 -067 Date: (� ordinances governing or local laws regulating Printed: 06 -11 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hUp://www.ci.tulavilawa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: e2 L.✓ 6, ! ` t 4 � 5 - Tenant Name: '(U SU ` A Property Owners Name: Mailing Address: Company Name: Mailing Address: H:\Applicationaorms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1.2009 bh E -Mail Address: 624 4F ( � Zf� rw Contact Person: E -Mail Address: Building Permit No. Mechanical Permit N Plumbing /Gas Public Works Permit.: Project No. (For `office use only) King Co Assessor's Tax No.: 7%i, 4-000 0 Z 5 4 Suite Number: 16 Floor: 1 New Tenant: K] Yes ❑ .. No City State CONTACT PERSON - who do we contact when your permit is ready to be issued Name: LA-Fe.--/ GP-4 l Day Telephone: Z% ? 5 Mailing Address: dh Z a tC - 7.5g.4( City Fax Number: GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5 Name: /^-LL C ( Ty Cc>i- 7i2/-1 _- Vt& --L-- -. C--- Mailing Address: ' C) .. 2 -2 V � TILE - 5( ( Z7 / ',, City State Zip Contact Person: L � C /zi ('(� Day Telephone: ZCc D5 7 5 7 E -Mail Address: 0121 t � I JL Z.O . cc* Fax Number: 2O ? 7 2 Ztj g (!J Contractor Registration Number: /- o� (O 7 6 (7 Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record City State City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zip Stat Zip Z c' c� Zip Day Telephone: 2.x(0 /-T7 J Fax.Number: ENGINEER OF RECORD - Ali Pia 'mast be, lye stamped by Eng Company Name: Mailing Address: State Zip Page 1 of 6 BUILDING PERMIT INFORMATION - - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ t GC:06 ' Existing Building Valuation: $ C. Scope of Work (please provide detailed information): J_-- I N SY /- 1__L_- 1 y { y _ 1 - P-ct) L A 17 & Cow M QC( l � l _ _ ((t i clffi N - UP C Z ? _ tLi. CFA is.--wokpotts 16 ?( SPAc&_- Will there be new rac st age? ❑ Yes ,6-No If y s, a separate permit and plan submittal will be required. l S ` Floor 2 Floor 3 Floor Floors Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Existing Provide All Building Areas in Square Footage Below Interior Remodel PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Addition to Existing Structure ❑ Sprinklers A Automatic Fire Alarm ❑ None H: \Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh New Type of Type of Construction per Occupancy per ' IBC � IBC Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 - 1/2" x 11 " paper including quantities and Material Sa ety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDI Signature: PrintiN Mailing Address: UTHORIZED AGENT: fL� Ge r c-Fi/y o B Z Date Application Expires: 1 —1 f1 H:'Applications \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1.2009 bh EdV Day Telephone: Ci Date: " 766 ' 5 7 5 State Zip Page 6 of 6 Fixture Type: Qty Fixture Typ . e: .- ° Qty...,: xture�_Typ'ei • .Qty Fizfure T,gpe: ::. ' • . , Qty Bathtub or combination bath/shower Bidet C , es washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain water cooler (pe ead) Food -w . >. e grinder, commerci Floor Drain Shower, single head trap Lavatory Wash fount& Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Wate eater and/or vent Industrial waste treatmen interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) epair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping edical gas piping em serving 1 -5 inle t. outlets for a speci 1: : Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each la .rinkler system on . one meter including back `.• w protection device Atmospheric -ty acuum breakers not i ded in lawn sprinkl ackflow protection -5) , Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets Mailing A ress: Valuation of Project (contrac Scope of Work (please provide PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: City Contact Person Day Telephone: E -Mail Address: Fax Number: Contractor Registrat 'n Number: Expiration Date: is bid price): $ Building Use (per Int'1 Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and /or gas piping outlet HAApplications\For ns- Applications On- Line\2009 Applications \t -2009 Permit Application.doc Revised: 1 -2009 bh tailed information): installed and the quantity below: Zip Page 5 of 6 Parcel No.: 0040000254 Address: 3920 S 146 ST TUKW Suite No: Applicant: BADAR GROCERY & PIZZA Receipt No.: R09 -00871 Payee: BADAR HALAL PIZZA Payment Cash Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci. tukwila. wa. us 000/322.100 000/345.830 640.237.114 Initials: JEM Payment Date: 06/11/2009 10:08 AM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT 109.50 Account Code Current Pmts Total: $109.50 Permit Number: D09 -067 Status: APPROVED Applied Date: 04/27/2009 Issue Date: Payment Amount: $109.50 100.00 5.00 4.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 06 -11 -2009 Receipt No.: R09 - 00640 Initials: User ID: Payee: JEM 1165 LARRY GRIFFIN Payment Cash Authorization No. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount RECEIPT 60.00 Account Code Current Pmts 000/345.830 60.00 Total: $60.00 • Parcel No.: 0040000254 Permit Number: D09 -067 Address: 3920 S 146 ST TUKW Status: PENDING Suite No: Applied Date: 04/27/2009 Applicant: BADAR GROCERY & PIZZA Issue Date: Payment Amount: $60.00 Payment Date: 04/27/2009 04:33 PM Balance: $109.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 04 -27 -2009 Project: Type of In ;pecti Addre 2 n { . ' 4 ` � ' !it/ J to Date Called: Special Instructions: - Date Wanted: Q a�r�i r 2 / .o f p.m. Requester: Phone No: _ 5 -sggo INSPECTION NO. INSPECTION RECORD Retain a copy with permit \PERMIT NO. CITY OF TUKWILA BUILDING DIVISION `14 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: - /1•12 /-" , -P - / - ,,-h t 4 i o/Fit / w / 4-/ i v a r F : 4,,0 ' - 3 A 4 / ,., / z y- o, ,carp " P3 Date: Approved per applicable codes. Corrections required prior to approval. 6 .00 REINSPECTION FE REp IRED. Prior to inspection, fee must be id at 6300 Southcenter d., Suite 100. Ca{{ to schedule reinspection. 1 Receipt No.: 'Date: COMMENTS: p R !I1 C. — j7 p,4tv 7 66 � _ 1.- d e 4, Projy t: ( / Type of Inspection: Address Date Called: IFeszig ,_.5.3a 'S Special - Instructions: / _mate Wanted: / C:17. / / 2 y A; .m., Requester: jj Phone No: INSPECTION RECORD Retain a copy with permit as INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3p7 pproved per applicable codes. Corrections required prior to approval. 6 Insp tor: i „ / 1ti �- R: ceipt No.: Date: // 7/ 60.00 REINSPECTIOtI FEE REG IRED. Prior to inspection, fee must be paid at 6300 SouthcenNer Blvd., uite 100. Call to schedule reinspection. 'Date: f'v INSPECTION RECORD Retain a copy with permit as INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3p7 pproved per applicable codes. Corrections required prior to approval. 6 Insp tor: i „ / 1ti �- R: ceipt No.: Date: // 7/ 60.00 REINSPECTIOtI FEE REG IRED. Prior to inspection, fee must be paid at 6300 SouthcenNer Blvd., uite 100. Call to schedule reinspection. 'Date: f'v Proje 0(04-r C, Type o Inspect' n: 1 Address: 3120 s 1 Date Called: iIJ A l mq Special Instructions: Date Wante 11 ( 7,4-(09 a �. Requester: Phone No: 17O' -0''? INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: (fln i rri'd Ujjti 1 /a(tf t) el,) �yv 4 J Coln e D — - vn � �" - 15 OK- - ¶ir'a (1d Inspector: (DS Date: q Itfrij El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ALL CITY CONTRACTING P.O. BOX 22196 Seattle, WA 98122 (206)909 -7552 May 14, 2009 City of Tukwila Bill Rambo — Permit Technician Cc/ At Metzler — Fire Project Coordinator 6300 Southcenter Blvd., Suite #100 Tukwila, WA 98188 RE: CORRECTION LETTER #1 Development Permit Application Number D09 -067 Badar Grocery & Pizza — 3920 S 146 St Subject: Fire Prevention Bureau Review Memo Al Metzler, Fire Project Coordinator This Letter is in response to Fire Prevention Bureau Review Memo — Dated May 1, 2009 from Al Metzler, The Original Plans Submitted are correct, There will be no tables and no chairs for food consumption in this occupancy, the floor plans submitted are accurate and there will be no revisions to Original Plans submitted. If any questions please contact, Larry Grin at (206) 909 -7552 Thank You REVIEWED FOR CODE COMPLIANCE' APPROVED I JUN 0 9 2009 CORREC 1,�a7 _ City of Tukwila BUILDING DIVISION 1 to OIi'7 FILE COPY Porr nit RECEIVED JUN 012009 PERMIT CENTt May 29, 2009 To Whom It May Concern: Re: Grease control program for Pizza Restaurant 3920 S 146' St. Valley View Sewer District has determined that a properly maintained bio- enzyme grease control system will be adequate for the Pizza Restaurant at 3920 S. 146 St. Please contact the District at 206 -242 -3236 to confirm proper installation of the bio- enzyme system. Sincerely, V,AL EY VIEW SEWER D STRICT Dana Dick General Manager DD /jw VJley VeTT" CORRECTION FILE COPY Permit No. REVIEWED FOR CODE COMPLIANCE APPROVED i JUN o u 2009 City of Tukwila BUILDING DIVPCinki RECEIVED JUN 012009 PEHMI r CENTER MICHAEL J. WEST PO. Box 69550 JOE T. COLELLO DANA DICK SEATTLE, WA 98168 RICK FORSCHLER GENERAL MANAGER 3460 SOUTH 148TH STREET SUIT E 100 COMMISSIONERS 206/242 -3236 FAX 206/242 -1527 LARRY GRIFFIN PO BOX 22196 SEATTLE WA 98122 RE: Permit No. D09 -067 3920 S 146 ST TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/08/2009. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 12/08/2009, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ` 40tAtv■L Bill Rambo Permit Technician File: Permit File No. D09 -067 City of Tukwila Department of Community Development Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 May 7, 2009 Larry Griffin PO Box 22196 SDeattle, WA 98122 Bill Rambo Permit Technician encl File No. D09 -067 • City of f TuI • Department of Community Development RE: CORRECTION LETTER #1 Development Permit Application Number D09 -067 Badar Grocery & Pizza — 3920 S 146 St Jim Haggerton, Mayor Dear Mr. Griffin, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Fire, and Public Works Departments. At this time the Building and Planning Departments have no comments. Fire Department: Alan Metzler at 206 545 -4407 if you have questions regarding the attached memo Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. I have also enclosed a Non - Residential Sewer Use Certification that must be completed prior to issuance of the permit. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenker service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, P:\Perrnit Center\Correction Letters\2009\D09 -067 Correction Letter #1.DOC wer Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 ® Tukwila, Washington 98188 ° Phone: 206 - 431 -3670 ° Fax: 206 - 431 -3665 Fire Prevention Bureau Review Memo Date: May 1, 2009 Project Name: Badar Grocery & Pizza Address: 3920 S 146 St, Suite B Permit #: D09 -067 Plan Reviewer: Al Metzler, Fire Project Coordinator Tukwila Fire Prevention Bureau Al Metzler, Fire Project Coordinator The Fire Prevention Bureau conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. 1. We have received information that there are tables and chairs for food consumption in this occupancy. The plans submitted state that there are no tables and chairs. Please submit an accurate floor plan that shows the placement of the tables and chairs and indicates the total square footage being used for the eating area. Should there be questions concerning the above requirements, contact the Fire Prevention Bureau at 206- 575 -4407. No further comments at this time. DATE: April 29, 2009 PROJECT: Badar Halal Food/Grocery & Pizza 3920 S 146 Street #B PERMIT NO: D09 -067 REVIEW NO: 1 PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. 1) Please submit an executed KC Non - Residential Sewer Use Certification, form is attached. List all new plumbing fixtures and do not list fixtures replaced in kind. 2) Applicant shall submit plans to Mr. Dana Dick, Valley View Sewer District at (206)242 -3236 for review and approval. A written Sewer District approval shall be submitted to Public Works. P: Joanna/Comments 1 D09 -067 PUBLIC WORKS DEPARTMENT COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards Joanna Spencer - RE: Badar Grocery +Pizza @ 3920 S 146th St D09 -067 From: "Dana Dick" To: "Joanna Spencer" Date: 06/03/2009 1:34 PM Subject: RE: Badar Grocery +Pizza @ 3920 S 146th St D09 -067 Joanna: I visited this site to determine if additional fixtures had been added. I determined that additional fixtures had been added on a plumbing permit issued in 2007. Since there is not any side sewer work required (it is all plumbing) I would not typically send the capacity charge form into the County. That is how Eunice Verstagen with Metro has advised me to handle those situations. I hope this answers your question. Dana Dick Manager Valley View Sewer District 206 - 242 -3236 phone 206 - 242 -1527 fax • • From: Joanna Spencer [mailto :jspencer @ci.tukwila.wa.us] Sent: Wednesday, June 03, 2009 11:33 AM To: Dana Dick Subject: Fwd: Badar Grocery +Pizza @ 3920 S 146th St D09 -067 Joanna Spencer Development Engineer City of Tukwila Public Works Department 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 -2544 phone: 206 - 431 -2440 fax: 206 - 431 -3665 jspencer @ci.tukwila.wa.us PERMANENT FILE COPY »> Joanna Spencer 06/03/2009 11:30 AM »> Dana, PW asked the applicant for a KC Metro Non -Res Sewer Use Cert to be submitted to PW. On the rev submittal form applicant stated tat Sewer Use Cert was submitted to the Sewer Distr. Did you receive it and should't it be submitted to PW, because it's a 11. Please let me know. Thanks, Page 1 of 2 file: / /C:\Documents and Settings \j oanna.TUKWILA\Local Settings \Temp\XPgrpwise \4A... 06/03/2009 Joanna Joanna Spencer Development Engineer City of Tukwila Public Works Department 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 -2544 phone: 206 -431 -2440 fax: 206 - 431 -3665 jspencer @ci.tukwila.wa.us • • Page 2 of 2 file: / /C:\Documents and Settings\joanna.TUKWILA\Local Settings\Temp\XPgrpwise14A... 06/03/2009 DEPARTMENTS: Building Division Public Works Complete Comments: Documents/routing slip.doc 2 -28 -02 • PERMITtOORDCOPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D09 -067 DATE: 06 -01 -09 PROJECT NAME: BADAR GROCERY & PIZZA SITE ADDRESS: 3920 S 146 ST Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: A re Prevention Structural DETERMINATION O COMPLETENESS: (Tues., Thurs.) Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg 11 Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS R UTING: Please Route Structural Review Required REVIEWER'S INITIALS: Planning Division Permit Coordinator DUE DATE: 06 -02 -09 DATE: Not Applicable No further Review Required DUE DATE: 06 -30 -09 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D09 - 067 PROJECT NAME: BADAR GROCERY & PIZZA SITE ADDRESS: 3920 S 146 ST, #B X Original Plan Submittal Response to Correction Letter # DATE: 04 -27 -09 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 13uilding Division, ii6 o () Ic Wor s Comments: 51l 6 1t o i i tt os•o(-Ci Fire Prevention Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DATE: GM AYD4r " Planning Division Permit Coordinator DUE DATE: 04-28-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS R UTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DUE DATE: 0526-09 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: 5 - 1--0 1 1 Bldg ❑ Fire Ping ❑ PW Staff Initials: Documents/routing slip.doc 2 -28-02 DATE: Revision istinnittak must be submitted in persion at the Permit Center. Revisions 164111101 be accred through the mil, fax, etc. Date: l9 -I`o Cl Response to Clete Letter Response to Correction Letter # 1 ❑ Revision # .. — after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project N BADAR GROCERY & PIZZA Project Address: 3920 S 146 St Contact Person: WO( C ccw( Phone Number: -. Z.C ) C C D sm o n: r e_ A-17 i AC M W 6 � , � 1 N-/q11 �L- � ��� U c� � �i c.u\ roy TT 69 V M L ( 1J/ E w X157` DA- N - r p« _JO9 7}1/4 3z3� Sheet Number(s): City j+ f TU a Department of Community Development 6300 Souk Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206431-3665 Web site: htin://www.cittdovila.wa.us °Cloud" or highlight ail areas of revision Received at the City of Tukwila Permit Center by g .---Entered in Permits Plus on I -0 1 Plan Check/Permit Number: ]D09 -067 Steven M. Mullet, Mayor Steve Lancaster, Director carr WntA JUN 0 12U09 PBRMlT CENTEP License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EASTSL'010D2 EASTSIDE LANDSCAPING CONSTRUCTION CONTRACTOR IRRIGATION /SPRINKLING SYSTEMS LANDSCAPING 3/22/1999 3/15/2001 ARCHIVED EASTSL *943JJ EASTSIDE LANDSCAPING CONSTRUCTION CONTRACTOR GENERAL UNUSED 4/11/20064/11/2008 07/27/2008 EXPIRED HUETALG000NT HUE TAN LE GENERAL CONTRACTOR CONSTRUCTION CONTRACTOR GENERAL UNUSED 8/30/20003/2/2006 REREGISTERED Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 UNDERWRITERS AT LLOYDS PFK039842 07 /26/2008 07/26/2009 $1,000,000.00 07 /25/2008 1 UNDERWRITERS AT LLOYDS PFK03708107 /26/2007 07/27/2008 $1,000,000.00 07 /31/2007 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 AMERICAN STATES INS CO 6512666 07/26/2007 Until Cancelled $12,000.00 07/31/2007 Name Role Effective Date Expiration Date LE, HUE T PARTNER /MEMBER 07/31/2007 GRIFFIN, LARRY PARTNER /MEMBER 07/31/2007 Untitled Page Other Associated Licenses Business Owner Information Bond Information Insurance Information • • General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company ALL CITY PLUMB Et HVAC LLC 2062554271 6197 118TH AVE SE BELLEVUE WA 98006 KING Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602748612 ACTIVE ALLCICP935MU CONSTRUCTION CONTRACTOR 7/31/2007 7/31/2009 GENERAL UNUSED Page 1 of 1 https: // fortress .wa.gov /lni/bbip /Detail.aspx 06/11/2009 REVIEWED FOR CODECOMPLIANCE APPROVED JUN 0`9 • • A .. • • .'s. • i IDV .D5 2007 SEPARATE PERMIT. REQUIRED FOR: ��4e chanical � e ctricai (5 Bing Id e as Piping Clty of Tukwila BUILDING DIVISION REVISIONS No changes ges shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan . submittal and may include additional plan review fees. DRAINBOARDS, UTENSIL RACKS, OR TABLES LARGE ENOUGH TO ACCOMMODATE ALL SOILED AND CLEANED ITEMS SHALL BE PROVIDED FOR NECESSARY UTENSIL HOLDING ...BEFORE CLEANING AND AFTER SANITIZING. WAREWASHING /DISHWASHING SINK COMPARTMENTS SHALL BE LARGE ENOUGH TO ACCOMMODATE IMMERSION OF THE LARGEST EQUIPMENT AND UTENSILS. HOT WATER GENERATION AND DISTRIBUTION SYSTEMS SHALL BE SUFFICIENT TO MEET THE PEAK HOT WATER DEMANDS THROUGHOUT THE FOOD ESTABLISHMENT. PLUMBING SYSTEMS SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED ACCORDING TO LAW (APPLICABLE LOCAL, STATE, AND FEDERAL STATUES, . REGULAT IONS AND ORDINANCES) RESTROOM & KITCHEN HAND WASH SINKS SHALL BE EQUIPPED TO PROVIDE WATER AT TEMPERATURE OF AT LEAST 100 DEGREES FAHRENHEIT THROUGH A MIXING VALVE OR COMBINATION FAUCET. SELF CLOSING OR METERING FAUCETS SHALL PROVIDEA FLOW OF WATER FOR AT LEAST 15 SECONDS. It is strongly recommended that hot water for the restroom hand wash sinks be plumbed from the main hot water heater ...instead of using an instant warm type water heater unit under each sink. BE THAT THE NEW WASHINGTON STATE FOOD CODE REQUIRES COMMERCIAL REFRIGERATION TO HOLD FOOD AT 41 DEGREES FAHRENHEIT OR BELOW III (DOWN FROM 45 DEGREES) FOOD SERVICE OPERATION AREA FLOORS, FLOOR COVERINGS, WALLS, WALL COVERINGS, AND CEILINGS SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED SO THEY ARE SMOOTH, DURABLE AND EASILY CLEANABLE. FOOD, FOOD PREPARATION AND FOOD SERVICE EQUIPMENT STORAGE AREAS ARE PROHIBITED UNDER SEWER LINES THAT ARE NOT SHIELDED TO INTERCEPT POTENTIAL DRIPS. Food equipment that is certified for sanitation by an American National Standards Institute (ANSI) accredited certification program will comply with the food code equipment & utensil material, construction and design requirements. LOCKERS OR OTHER SUITABLE FACILITIES SHALL BE PROVIDED FOR THE ORDERLY STORAGE OF EMPLOYEES' CLOTHING AND OTHER POSSESSIONS. MIDPLEBY MARSHALL 15 -250. - SIZE 1 VGIC30848 30" SEALED BURNER RAN NO CHANGES SHALL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL AF's : :' IONAL- INSPECTION 13 THE KING COUNTY ALT11 DE PARTME NT IS REQ UIRED P RIOR: T4 OPERATION: AP PLAN. }. SET IS REQUIRED BE AZIATLECTION: : ABLE- ON SITE D URING THAT TO INSP APPROVED • SUBJECT TO ORDINANCE • - • APR 2.1 2009 CO' f P bit Health 1 Q 7 9 ' - �C craE -: uc 1 Pizza it it z ' Large $15.00 2 Pizza Medium 10.00 Sugar ( Beef ) with Anjera or Bread Sugar ( Chicken ) with Anjera or Bread Rice with Lamb or Goat (steamed) Spaghetti with Lamb or Goat (steamed) Beef (pan fried) Fish (pan fried) Sambusa Sambusa Bur Bread Nafaqu ( eggs with mashed potatoes ) Anjera ( single ) Malawa ( Burn Cake ) Beverage's SUPPL.IER'S and VENDOR'S 1 Resturant Depot (www,resturantdepot) 2 Costco 3 Cash & Carry 4 International Food Bazzar East Valley - 6.74- HAUDWASH SINK $ SI4ALL BE EQU1 PPE3 * r ER PERAT— E o. AT :LEAST. - 1000 ° - F _ NERATI 0W 1.161 ICITCHE �R SUITABLE !` ACIUT 1E,S . SHAL,L. BE PROVIDED >:'1'ORAGi OF EMPLD VEES' .CLOTH11461. AND .=HER . ERATION AREA FLOORS; MOOR: C+ 'IER NGi% WAS, Na CE ILINGI S SHAkL BE ' 'ZIESIONED;ZONSTR TNT 4' -ARE SMOO"i'N. Du sirg AND RAGS I LY D EGIGIIv.ED, :CONS TED AND' S1•ATE AND 0744.: co ?E. VASHtNto Slhit ' CAM PAO M WS 'SHALL "'MOD TE .IMMERSION OF . TOE LARGEST 8.00 8.00 9.00 9.00 1.00 1.00 1.00 1.00 1.00 1.00 2.00 1.00 1.00 APPLICANT COPY NO CLEARENCE REQUIRED BETWEEN HOOD AND A SMOOTH, CLEANABLE, NONCOMBUSTIBLE GWB CEILING TILE WITH NON- COMBUSTIBLE STRUCTURES IS INSTALED BETWEEN THE HOOD AND OVER AN AREA ` EXTENDING NOT LESS THAN 18" IN ALL DIRECTIONS FROM ;THE HOOD (PER IMC 2006 SEC. 507.9.EXCEPTION) SEAL AROUND DUCT PANETATION W/ 3M FIRE COLKING. NON- COMBUSTIBLE T BAR CEILING IN KITCHEN AREA �i HOOD HANGER ' 6" MIN. SPACE TO COMBUSTIBLE WALL W/ PROTECTION PER IMC table 308.6 22 GA. S.S..1 " THICK MINERAL WOOL INSULATED FIRE 5/8" PAD TYPE OVER X GW ` EXISTING B AS FLASHING. 18" MIN. OVER EXHAUST HOOD AND DUCT TOP AND SIDE EDGES EXISTING PARAPET 17"X17" 16G. GAL. STEEL ALL LIQUID TIGHT WELDED EXHAUST DUCT. 4 BURNER W/ OVEN 10'' MIN. TO ANY AIR INTAKE AND • PROPERTY LINE IN ANY DIRECTION; 10'MIN. FROM SAME OR ADJACENT BUILDING TYP. ` FIRE 3" MIN. OVER LAY. TYP. OVERLAY DETAIL FIRE WRAP MATERIAL SEE ATTACHED 3M 15A SPAC. FOR DETAIL ROOF TR 3/8 THREADED ROD 3/8 HEAVY DUTY LOCK NUT ABOVE AND BELOW HANGER BRACKET —HOOD FRONT S.S. . HANGER -4X4 W/ SIMPSON H2.5T EACH SIDE EACH END TO ROOF TRUSS HOOD FRONT HANGING VENTED 10' MIN. FROM ANY HAZARDOUS OR NOXIOUS CONTAMINANT SOURCE 18 "MIN.�I' 16 "X17. OR EQUIVALENT AREA, 26 GA. ' MIN. GALV. STEEL MAKE -UP AIR DUCT. = JOINT SEALED jJJjJJ SIMPLIFIED FLOOR PLAN -HOOD UPBLAST EXHAUST FAN SHALL BE HINGED AND SUPPLIED ` WITH A FLEXIBLE WEATHERPROOF ELECTRICAL CABLE. TYP. 1 EXISTING PARAPET 16 "X17" OR EQUIVALENT AREA, : 26 GA. MIN. GALV. STEEL MAKE -UP AIR DUCT. ALL JOINT SEALED NON– COMBI�STIBLE T BAR CEILING IN I AREA -7 PREP AREA 10'. MIN. TO ANY AIR INTAKE AND PROPERTY LINE IN ' ANY DIRECTION; 10'MIN. FROM SAME OR ADJACENT BUILDING SCALE: 1 /2 " =1' 0" 12' TYPE HOOD PIZZA OVEN FILTERS— S: GRAESE CUP LEVATION /SECTION DETAIL 'PROJECT ,SITE S - 146TH S 1013.5 Mech ideal Equipment. Guards shall be provided where appli es, 'equipment, fans, roof hatch opening or other compon nts that require service are located within 10- feet of a roof ae or open side of a walking surface and such edge or open side is located than 30- inches above the floor; roof or grade below. The guard shall be constructed so as to prevent the passage of a 21- inch - diameter sphere: The guard shall extend not less than 30- inches beyond each end of such appliances, equipment, fan or component. 1013.6 Roof Access. Guards shall be provide where the roof hatch opening is located within 10 -feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30- inches above the floor, roof or grade below. The ` guard shall be constructed so as to prevent the S 150th ST S 1441 h ST THE DISTANCE FROM EXHAUST FAN TO BUILDING PARAPET SHALL NOT LESS THEN 2 FT PROVIDE EXHAUST OUTLET IS NOT LOWER THEN PARAPET. (IMC 506.5.5: EXCEPTION) EXISTING CMU EXTERIOR • WALL >EE DETAIL .0 FOR HANGER DETAIL 17 "X17" 16G. GAL.STEEL ALL LIQUID TIGHT WELDED EXHAUST DUCT. FIRE PAD EXTENDING 18" MIN ABOVE HOOD SEAL AROUND DUCT PANETATION W/ 3M FIRE COLKING. TYP. 1 HR MIN. FIRE WRAP 6" MIN. SPACE TO COMBUSTIBLE . WALL W/ PROTECTION PER IMC table 308.6 - 22 GA. S.S. 1" THICK MINERAL WOOL INSULATED FIRE PAD OVER EXISTING 5/8" TYPE X GWB AS FLASHING. 18" MIN.: OVER EXHAUST HOOD AND DUCT TOP AND SIDE EDGES S 146th ST PARCEL ADDRESS: 3920 S 146TH ST, TUKWILA, WA 98168 LEGAL DESCRIPTION: ADAMS HOME TRS LESS N 210 FT, ` LESS S 10 FT LEI PROPERTY OWNER: POLL TUKWILA LLC FAN LOCATION ON ROOF POR ELY: OF HWY BUISNESS: BADAR GROSERY AND PIZZA 111 C I 3920 S 146TH ST, #B TUKWILA, WA 98168 . - OCCUPANCY: M, RETAIL & DEU SHOP Ttsetof bekeptatthe S no changes shall of work .whho_. . Tukwila Buit L9TE: Revisions will requi and may include additioi ora� 777 . City of kH! 12' TYPE I HOOD NOTES: - ita (1) HOOD: BUILDIN - DIVISI+ ONE 12'-0" FT LONG TYPE I COMPENSATING S.S. CANO•Y HOOD. UL LISTED ( #46AJ) AND NSF APPROVED • MODEL # MIFD -42. MIN. 20 GA TYPE ;'304 OR TYPE 430 STAINLESS 4 STEEL CONSTRUCTION WITH_ FINISH AT EXPOSED SURFACE; `EXHAUST PLENUM:! 16 GA. `:GALVANIZED STEEL ALL WELDED; FILTER BANK: SUPPLIED WITH UL. CLASSIFIED 20X20X2 REMOVABLE BAFFLE T(PE, GREASE RECEPTACLE PROVIDE AT LEST ONE REMOVABLE GREASE RECEPTACLE. 2) EXHAUST DUCTS 17"X17 OR EQUIVLANT AREA, 16 GA. GALVANIZED STEEL ALL WELDED CONSTRUCTION. ONE HOOD OUTLET S ALL SERVE NOT MORE THAN A 18' SECTION ; OF` HOOD PER UL LISTEAD HOOD. (3) CONTINUOUS ENCLOSURE CONSTRUCTION: 3M FIRE BARRIER DUCT. WRAP. (ONE HR MIN. FIRE RATED. UL, ICBO, ASTM TESTED AND LISTED PRODUCT) CONTINUOUS DUCT ENCLOSURE SHALL _BE SEALED AROUND THE DUCT AT_THE POINT OF, PENETRATION, AND VENTED.:. TO THE EXTERIOR THROUGH A. WEATHER, PROTECTED OPENING. (4) EXHAUST FAN: DAYTON GREASE TYPE KITCHEN EXHAUST FAN, 4YY19, UP BLAST ROOF MOUNT. 5006 _ CM* t 0:75 IN:SP, 115/230V, 1 PH, 1.5 HP. NOISE 23 ` SONES ' (73.21 J 2 dBA) (SEE ATTACHED MANUFACTORY 'DOCUMENT .FOR- DETAILED.:. SF.ECIFICATION (5) MAKE -UP FAN: ARCTIC CIRCLE. MODEL #: US440B 4500 `CFM @ 0.25 IN.SP.,115 V, 1 PH, 1/2 HP (SEE ATTACHED..:MANUFACTORYD000MENT FOR DETAILED SPECIFICATIONS) (6) EXHAUST FAN, MAKE -UP AIR FAN AND GAS LINE TO BE ELECTRICALLY INTERLOCKED; • FIRE SUPPRESSION SYSTEMS BY OTHERS. SHOULD PROVIDE SEPARATE PLAN FOR APPROVAL. WORK WILL CONFORM TO UL 300, NFPA96, IBCO3, IMCO3; AND ALL LOCAL, STATE CODES (8) ` ALL DESIGN AND WORK WILL` CONFORM TO IMC -06, UL 300, NFPA96, ALL LOCAL, STATE CODES AND INSURANCE REQUIREMENT. HOOD EXHAUST & MAKE -UP AIR CALCULATIONS HOOD RATE REQUIRED DUCT SIZE . DUCT AREA FPM (LF) (CFM /LF) HOOD CFM EXHAUST 12' 400 4800 17 "X17" 2.01 SF 2388 MAKE -UP 90% OF EXHAUST 4320 16 "X17" 1.89 SF 2286 PERFORMANCE, CAPTURE AND CONTAINMENT TEST - REQUIRED PER SMC 507.16 & 507.6.1 GRAESE DUCT LEAKAGE TEST SHALL BE PERFORMED FOR THE ENTIRE DUCT SYSTEM PER IMC 2006 SEC; 506,3.3.1. EXHAUST FAN ON ROOF: 17' TO EAST P.L. 56' TO NORTH P.L. 232' TO WEST P.L. \44' TO SOUTH P.L. RESTAURANT EQUIPMENT MFG.: DESIGN`: & CONSULTANT 9832 17th AVE. SW Seattle, WA 98106 TEL. 1200)767 -6647 FAX: ' (206)767 -6689 ** MUTUII041D5 ** THIS DOCUMENT ENCLOSES DESIGN CONCEPT, INFORMATION . AND DATA PROPRIETARY TO MUTUAL INDUSTRIES INC. WHICH ARE NOT TO BE DISCLOSED OUTSIDE THE RECEMNG ORGANIZATION NOR REPRODUCED IN .WHOLE OR PART. EXCEPT BY PRIOR WRITTEN CONTRACTUAL ARRANGE MENTS WITH . INDUSTRIES INC. DESIGN CONTACT: DAVID LEE (206)817-6081 EMAIL: david6081@gmail.com AR 1 GROSEg . ° TYPE I... R8QUIRED REVISIONS: ARATF PF RESUBMIT PER REQUIRED TYPE 1 HOOD THIS PLAN TO REPLACE PREVIOUS SUBMITTED- .TYPE ..II. HOOD PLAN . MpliqUDIVISic SHEET TITL -- A: HOOD FRONT ELEVATION - B: TYP. HOOD SIDE ELEVATION - - C: HOOD FRONT HANGING DETAIL - - FIRE WRAP OVERLAY DETAIL al" - GENERAL NOTE AND INFORMATION -- . SITE PLAN (REFLECT ROOF UNIT LOCATION) HOOD LOCATION ON SIMPLIFIED FLOOR PLAN