Loading...
HomeMy WebLinkAboutPermit D09-083 - HAIR CLUB FOR MEN & WOMEN - SECOND FLOOR TENANT IMPROVEMENTHAIR CLUB FOR MEN & WOMEN 545 ANDOVER PK W D09 -083 Parcel No.: 2623049144 Address: 545 ANDOVER PK W TUKW Suite No: Tenant: Name: HAIR CLUB FOR MEN & WOMEN Address: 545 ANDOVER PK W , TUKVVILA WA Cityf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa. Owner: Name: SOUTHCENTER CORPORATE SQUAR Address: 150 CALIFORNIA ST , SAN FRANCISCO CA 94111 Phone: Contractor: Name: D P INC GENERAL CONTRACTORS Address: 19909 BALLINGER WAY NE , SEATTLE, WA 98155 Phone: 206 - 361 -2989 Contractor License No: DPINCGC066BU doc: 1BC -10/06 DEVELOPMENT PERMIT Contact Person: Name: TAMARA GENZALE Address: 635 ANDOVER PK W SUITE 107 , TUKVVILA WA 98188 Phone: 206 -575 -3080 Permit Number: D09 -083 Issue Date: 07/09/2009 Permit Expires On: 01/05/2010 Value of Construction: $30,000.00 Fees Collected: $1,040.37 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: V -B Occupancy per IBC: 0008 Expiration Date: 01/31/2010 DESCRIPTION OF WORK: 2ND FLOOR TENANT IMPROVEMENT TO INCLUDE DEMOLITION OF EXISTING PARTITIONS, ADDITION OF NEW PARTITIONS, DOORS, RELITES AND OTHER FEATURES * * continued on next page ** D09 -083 Printed: 07 -09 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non- Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: doc: IBC -10/06 City cfinukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D09 -083 Issue Date: 07/09/2009 Permit Expires On: 01/05/2010 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the • erfo s ance of yy/ork. I arty authorized to sign and obtain this development permit. Date: 7 - 1 - 6 q Signature: Print Name: J0 5 Q/) \ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -083 Printed: 07 -09 -2009 Parcel No.: 2623049144 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 545 ANDOVER PK W TUKW HAIR CLUB FOR MEN & WOMEN 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D09 -083 ISSUED 05/22/2009 07/09/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 8: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 D09 -083 Printed: 07 -09 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www. ci. tukwila. wa. us 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 25: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 26: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 28: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) doc: Cond -10/06 D09 -083 Printed: 07 -09 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 29: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 33: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** D09 -083 Printed: 07 -09 -2009 • • City of Tukwila I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Cond -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: 7 - D09 -083 Printed: 07 -09 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Aulfvfl[ WE' 98188 SITE LOCATION Site Address: 545 Andover Park West Tenant Name: Hair Club for Men & Women Property Owners Name: Meriwether Partners Mailing Address: 1191 Second Avenue, Suite 1570 CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Tamara Genzale Mailing Address: 635 Andover Park West, Suite 107 E -Mail Address: tgenzale @prmc.com GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: DP, Inc. Mailing Address: 19909 Ballinger Way NE, Suite 101 Contact Person: Bill Dodson E -Mail Address: bill @dpinc.net Contractor Registration Number: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Marvin Stein & Associates Mailing Address: 2221 5th Avenue Contact Person: Lisa Bolster E -Mail Address: I.bolster @marvinstein.com E -Mail Address: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Zip Contact Person: HA\Apphcations \Forms - Applications On Lme \2009 Applications \1 -2009 - Permit Application :doc Rer iced- 1 -20119 bh B ildi Aganiat Fax 90310 Da 3 Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. King Co Assessor's Tax No.: 2623049144 Suite Number: 209 Seattle City Day Telephone: (206) 575 -3080 Tukwila WA 98188 City Fax Number: Seattle City State Day Telephone: (206) 361 -2989 (206) 362 -3665 Fax Number: Expiration Date: Seattle (For office use only) 2 New Tenant: ❑ Yes ..No 98101 Zip WA State Floor: State Zip Z� S S - 5t l �g City State Day Telephone: (206) 441 -1449 Fax Number: (206) 441 -4361 WA 98155 City Day Telephone: Fax Number: Zip WA 98121 State Zip Page 1 of 6 . : • . , . Existing " •.,, Interior:Remodel Addition to ••.•'. Existing` Structure New Type•of,. Construction per IBC Type of Occupancy per .. IBC .1 Floor.': . . tOt 921 1,278 VB B 3 - e. • 'floors .::.6.11)ii Basement,. �7". . • . •Accessoryq$tructure* . t •, ;, Attached Garage . :;Deiached Garage Attached Carport Detached ;Carport ,Gove'red Deck • ' -'• .Uncovered Deck ' " BUILDING PERMIT.INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 30,000 Existing Building Valuation: $ Scope of Work (please provide detailed information): 2nd floor tenant improvement to include demolition of existing partitions, addition of new partitions, doors, relites and other features. Will there be new rack storage? ❑ Yes Z.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Fpotage'Below. PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: m Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: 1Applications1Forms- Applications On Line12009 Applications\l -2009 - Permit Application.doc Revised: 1.2009 bh Page 2 of 6 PERMIT APPLICATION NOTES - .Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 .: ' OR AU J. • ED AGENT: Signature: V tit Print Name: Mailing Address: H:Wpplications \Forms-Applications On Line \2009 Applications \I -2009- Permit Application doc Revised: 1 -2009 bh Date:61 IO Day Telephone: Zae) S7S &)M .S 1.4 ..1L/ Il .I 0 City Sta e Zip Date Application Accepted: 6 , Date Application Expires: 1 l o ff Staff Initials: — Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049144 Permit Number: D09 -083 Address: 545 ANDOVER PK W TUKW Status: PENDING Suite No: Applied Date: 05/22/2009 Applicant: HAIR CLUB FOR MEN & WOMEN Issue Date: Receipt No.: R09 - 00770 Initials: WER User ID: 1655 Payee: SOUTHCENTER CORPORATE SQUARE TRANSACTION LIST: Type Method Descriptio Amount ACCOUNT ITEM LIST: Description doc: Receipt-06 Payment Check 2448 1,040.37 Authorization No. BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 640.237.114 RECEIPT Total: $1,040.37 Payment Amount: $1,040.37 Payment Date: 05/22/2009 03:09 PM Balance: $0.00 627.80 408.07 4.50 Printed: 05 -22 -2009 Project: Icor CLttfl r=oR Ifr.1 Type of Inspection: FI Jfi Address: 645 A N Ochieg Pt Date Called: Special Instructions: Date Wa ted: ( I 1 �p-rrf Requester: Phone No: PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION NO. ig Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: P.c." - t ( f //04 /;;L T � Spector i IDaTi // 61./a7 REINSPECTION FE REQU ED. Prior to inspection, fee must be at 6300 Southcenter B d., 5 ite 100. Call to schedule reinspection. Re - pt No.: 1 (Date: INSPECTION RECORD Retain a copy with permit eft -G S3 (206)431 -3670 cg Prgjec f ,� T r v � I; r et, 14-e- ^ �t� ` Type of Inspection: � crq. L.- 1h ' A y Address: s ue' 5 Ago o v € -r Ltmsr Date Called: Special Instructions: Date Wanted :�a�.m� '�"'� (7� p.m. Requester: Phone No: 2 (0 '7 — q5‘I INSPECTION NO. INSPECTION RECORD Retain a copy with permit L 6 - 08'3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Date/L El $6 i . ' 0 REINSPECTI01i FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project; Type of Inspection: , Address: J J �f 4 � / Date Ca led: ) Special Instructions: / Date Wanted: i ` a p .m : 7 - — J Requester: Phone No: • �Jo -osr3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. / CITY OF TUKWILA BUILDING DIVISION f, /" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36/0 pproved per applicable codes. Corrections required prior to approval. COMMENTS: DK— fi-D A !t Inspectl: Date: --1 . 2-r - �1 LJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: p .0 , Type of Inspection: Al -- f�R /A/6\ Address: / 5 4/vc' /DIP, Y7/e GtJ NO ikJ — / 7 issi RfA/6, r j#4 // s Special Instructions: d /4- To e p.m. Requester: f Phone No: 02o6 - 75"_.?- 5.- G/ 1 /V ire; HiI'��'is-/ ,,at' e- g / !ij/ - . . / ---- ?i ,, ` \ Project: /249 /i C/2/6 I/6 raP�FAI Type of Inspection: Al -- f�R /A/6\ Address: / 5 4/vc' /DIP, Y7/e GtJ Date Called: Special Instructions: Date Wanted: 7 — p.m. Requester: Phone No: 02o6 - 75"_.?- 5.- G/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION l 6300 Southcenter Byrd., #100, Tukwila, WA 98188 Approved per applicable codes. II pector: Rece ". t No.: ovimi 6d5ci3 (206)431 -36 orrections required prior to approval. Date: $ 0 REINSPECTION FEE RE DIRE . Prior to inspection, must be p- at 6300 Southcenter Blvd., uite 00. Call to schedule reinspection. !Date: Project: 14411? cIE, b -c me4 LLc.. Type of Inspection: iY 10i j 1.5 Address: APO Suite #: Contact Person: �p 5,,,, oat.: el lc Li , i — Special Instructions: Phone No.: .ZbL • a ss - - 7bT 7 Needs Shift Inspection: Sprinklers: - Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 2. INSPECTION NUMBER INSPECTION RECORD Retain a copy With permit CITY OF TUKWILA FIRE DEPARTMENT o9- C. /03 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 MA pproved per applicable codes n Corrections required prior to approval. COMMENTS: 7 9)'i 4, ii4. ' ere. r .. �4 7 --- orr 1 spector: . $Sj pei Date: id 7w Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc • 1/13/06 T.F.D. Form F.P. 113 COMMENTS: • F$ "el,* i Address: c Suite #: 0 4 old eot 1-1441eit-- paa. mottle (..4 .:‘,..1. 1D '`'9 Special Instructions: Phone No.: x7©( -9 / • • f. 4' i r,.i ; d Ate.. ' Project: iuki 4 ,, M erl ltd+ , L Type of Inspection: fled. �j 4d pi F$ "el,* i Address: c Suite #: hers Contact Person: $ 1D '`'9 Special Instructions: Phone No.: x7©( -9 / Needs Shift Inspection: & • Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre =Fire: Permits: Occupancy Type: r a INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT »o2- as►' 09- 1' o &9 • PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. n nspector: Date: j / I, /D9 . Hrs.: UIRED. • You will receive an invoice from $80.00 REINSPECTION FEE REQ • the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 I I Corrections required prior to approval. T.F.D. Form F.P. 113 Project: HA? C1446 44. 111.64 Type of Inspection: Address: is - Suite #: i9 Pk/. Hoodik Duct: Contact Person: SOivi /54) Gi ede44.-i Special Instructions: 'Permits: - d Phone No.: ,2 z Inspection: Sprinklers: g r eetl'IShift i Alarm: Hoodik Duct: Monitor: / Pm-Fire: 'Permits: - Occupancy Type: 44.4•4I• • .4 0: • INSPECTION NUM • CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Approved per applicable codes. COMMENTS: 0 A''..r.oeobe.:s 1mr5 • 1 -Inspector: Sc/'if) $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department; Call to schedule a reinspection. Word/Inspection Record Foirn.Doc • INSPECTION RECORD Retain a copy with permit R‹rrections required prior to approval. I Date: N/0/01 ,005 dOg 1)9 r-i stl PERMIT NUMBERS 1/13/06 T.F.D. Form F.P. 113 Pro'ect: 1 a CAS, _S Type of Ins on: -- - -. _- S f C - �--- 47 Address: ' Suite #: OAP Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: - - Sprinklers: . Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION RECORD Retain a copy with pernmit CITY OF TUKWILA FIRE DEPARTMEN INSPE ON NUMBER PERMIT NUMBERS 4r T 444 Andover Park East Tukwila, Wa. 98188 206 - 575 -4407 • Approved per applicable codes. _Llr'f Corrections required prior to approval. COMMENTS: Word /Inspection Record Form.Doc 1/13/06 Inspector: I Date: e/ / ..- H'1 Hrs.: n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department Cali to schedule a reinspection. T.F.D. Form F.P. 113 r June 22, 2009 Tamara Genzale 635 Andover Pk W, Ste 107 Tukwila WA 98188 fer Marshall Pe it Technician encl File No. D09 -083 so Department of Community Development RE: CORRECTION LETTER #1 Development Permit Application Number D09 -083 Hair Club for Men & Women — 545 Andover Pk W, Ste 209 Dear Ms. Genzale, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time the Building, Fire, and Planning Departments have no comments. Public Works Department: Dave McPherson at 206 431 -2448 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. I have also enclosed a Non - Residential Sewer Use Certification that must be completed prior to issuance of the permit. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, W:\Pem» t Center\Correction Letters\2009\D09 -083 Correction Letter #1.DOC jem Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DATE: June 19, 2009 • PUBLIC WORKS DEPARTMENT REVIEW COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards PROJECT: Hair Club for Men and Women 545 Andover Park West PERMIT NO: D09 - 083 PLAN REVIEWER: Contact David McPherson, Development Engineer (206) 431 -2448, if you have any questions regarding the following comments. 1) In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross - connection control program to protect the public water system from contamination via cross - connection. The City has determined that the Hair Club for Men building has deficiencies on domestic and irrigation backflow devices; requiring the following upgrades. a) Domestic Water Service A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the permanent water meter. Installation at another location requires approval by the Director of Public Works. The RPPA shall be installed in a Hot Box/Hot Rock or equal freeze protection enclosure anchored to a minimum 4" thick concrete pad. Public Works recommends, but does not require, a power supply for the freeze protection enclosure. Please specify RPPA size, manufacturer, and model number on plans and submit a cut sheet for the proposed device. Show location of the new RPPA on a plan sheet. b) Landscape Irrigation An AMR upgrade to the existing irrigation deduct meter is required. The lid on the existing irrigation DCVA box, needs to be replaced. The current one is broken and is a hazard. c) Fire Prevention The fire backflow prevention device (DCDVA) is current. If you opt to bond for the installations, you must provide the following to the Permit Center (1) an original installation estimate (2) a bond for 150% of the installation cost (3) a letter stating your intent to install the device by a certain date. This must be done before the Permit Center issues the permit for your Tenant Improvement. The Director of Public Works will withhold issuance of this Tenant Improvement permit until the Permit Center receives plans for item 2 (a) and 2 (b) for Public Works approval; or a bond for 150% of the design and installation cost of subject devices, together with a letter stating the installation by a certain date. I have enclosed Public Works Development Bulletin CS (design and installation requirements for cross connection control) and Bulletin A2 (permit fee estimate sheet). 1 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D09 -083 DATE: 07 - - PROJECT NAME: HAIR CLUB FOR MEN SITE ADDRESS: 545 ANDOVER PK W Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Di isi n Pu blic Works Fire Prevention Structural DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 Incomplete n DUE DATE: 07-07-09 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R UTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 08-04-09 Not Approved (attach comments) n DATE: Planning Division Permit Coordinator Not Applicable C Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D09 -083 DATE: 05 -22 -09 PROJECT NAME: HAIR CLUB FOR MEN & WOMEN SITE ADDRESS: 545 ANDOVER PK W X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: uuilding i'ision oW eAk o Public Works Complete Comments: Please Route Notation: PLAN REVIEW/ROUTING SLIP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) J Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: REVIEWER'S INITIALS: • Structural Review Required APPROVALS OR CORRECTIONS: Approved n Approved with Conditions REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: IKG hY Departments issued corrections: Documents/routing slip.doc 2 -28 -02 - gt PWG lgl 0 Fire Prevention Structural Incomplete Bldg ❑ Fire ❑ TCOORD Ping ❑ PW ❑ Permit Coordinator DUE DATE: 05-26-09 No further Review Required DATE: NIA . °° 1 Planning Division Not Applicable DUE DATE: 06 -23 -09 Not Approved (attach comments) DATE: Staff Initials: ''`/- City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us $f �° REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7/a/ Plan Check/Permit Number: ❑ Response to Incomplete Letter # R TO D_LA ▪ Response to Correction Letter # � CAN �F 1�1 VVVII ❑ Revision # after Permit is Issued JUL WI ?N9 ❑ Revision requested by a City Building Inspector or Plans Examiner PERMIT CENTER Project Name: H ( I l., FOP- 1-1 1\) £ Iij0i v DO9-os Project Address: 5 /4" u. JogtilNA' 5/345'1"-- C..6 n Z �,R Contact Person: 0-G¢' Phone Number: 02/06 - S T S-3O O ' ' / Summa of Revision: r -P� 5G) J e /e c C gPpiq- r e- i-A b ti (, 7/06/09 R,PPAt r i Gt- mil / 4e a. �Ca o- 6 ( teii /S/��- -�t,� � 7/ Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 01-1 w I O \applications\forms- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status PATTICCO34MH PATTISON CONSTRUCTION CO LLC CONSTRUCTION CONTRACTOR GENERA UNUSED 7/8/1997 2/17/1998 ARCHIVED PATTICA066DQCONSTRUCTIONCONTRACTOR PATTISON Et ASSOC CONSTRUCTION GENERAL UNUSED 3/18/1994 2/17/1998 ARCHIVED DODSOP1101J6 DODSON PATTISON INC CONSTRUCTION CONTRACTOR GENERA UNUSED 4/2/1990 3/26/1994 ARCHIVED ACECO * *179L0 ACE CONSTRUCTION CONSTRUCTION CONTRACTOR CARPENTRY /FRAMING PAINTING /WALLCOVERING 6/20/1983 6/16/1986 ARCHIVED VANSND *176B0 VANS NORTHWEST DRYWALL CONSTRUCTION CONTRACTOR DRY WAL PAINTING /WALLCOVERING 1/20/1983 11/1/1983 ARCHIVED ALLAMD *184BN ALL AMERICAN DRYWALL CONSTRUCTION CONTRACTOR DRY WALL PAINTING /WALLCOVERING 1/15/1982 1 /15/1983 ARCHIVED Name Role Effective Date Expiration Date DODSON, WILLIAM PRESIDENT 01/31/1994 Bond Amount Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 DEVELOPERS STY Et DEMNITY CO 7 91078C 01/31/2008 Until Cancelled $12,000.0002/25 /2008 4 CBIC SA6377 01/31/200201/31/2008 $12,000.0001 /09/2002 3 CBIC SA6377 01/31/199801/31/2002 $6,000.00 2 CBIC SA6377 01/31/199701/31 /1998 $6,000.00 AMERICAN Untitled Page • • General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company D P INC GENERAL CONTRACTORS 2063612989 19909 BALLINGER WAY NE SEATTLE WA 98155 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601515833 ACTIVE DPINCGC066BU CONSTRUCTION CONTRACTOR 1/31/1994 1/31/2010 GENERAL UNUSED Other Associated Licenses Business Owner Information Bond Information Page 1 of 2 https: // fortress .wa.gov /lni/bbip/Detail.aspx 07/09/2009 ACT ACOUSTICAL CEILING TILE LL @TE BY LANDLORD AT TENANTS EXPENSE AN ADJACENT/ADJUSTABLE AFF ABOVEFINISHFLOOR MAX LINEAL ALT ALTERNATE MECH MECHANICAL ALUM ALUMINUM MFR MANUFACTURER APPROX APPROXIMATELY MIN MINIMUM @ AT MISC MISCELLANEOUS BFP BLANK FACE PLATE MTD MOUNTED BLDG BUILDING MTL METAL BLKG BLOCKING MW MICROWAVE OVEN B/S CABINET STANDARD N NORTH, NEW N/A NOT APPLICABLE CLR CLEAR/CLEARANCE NIC NOT IN CONTRACT CLG CEILING NO NUMBER CL CENTERLINE NOM NOMINAL COL COLUMN NTS NOT TO SCALE COMM COMMUNICATION OC ON CENTER COMP COMPOSITION OPNG OPENING CONST CONSTRUCTION OPP OPPOSITE CONT CONTINUOUS ORIG ORIGINAL CPT CARPET CERAMIC OR CONCRETE TILE PERM PERMANENT CT PL PLATE DIA DIAMETER PLAM PLASTIC LAMINATE DIM DIMENSION PLYWD PLYWOOD DR DOOR PR PAIR DW DISHWASHER PTR PARTITION DWG DRAWING R RADIUS, REMOVE, RELOCATE E EXISTING, EAST RB RUBBER BASE REINF REINFORCING EA EACH REF REFRIGERATOR UIRE ELEC ELECTRIC ELEM. ELECTRICAL REQ'D REQUIRED E ELEVATION (VIEW) REV REVISION/REVERSE QUIRE EXIST EXISTING ROOM EXT EXTERIOR RO ROUGH OPENING FIN FINISH S SOUTH FLR FLOOR SCHED SCHEDULE FLUOR FLUORESCENT SC SOLID CORE SECT SECTION FR FIRE RATED FT FEET SIM SIMILAR FURN FURNISH /FURNISHINGS SPEC SPECIFICATION GA GAUGE SQ SQUARE GALV GALVANIZED STD STANDARD GD GARBAGE DISPOSAL STL STEEL GL GLASS /GLAZING STOR STORAGE GWB GYPSUM WALL BOARD SUSP SUSPENDED HC HOLLOW CORE TEL TELEPHONE HDW HARDWARE TYP TYPICAL HM HOLLOW METAL UNO UNLES NOTED OTHERWISE VCT VINYL COMPOSITION TILE HT HEIGHT VERT VERTICAL HVA HEATING, VENTILATING, AIR CONDITIONING W WEST IN INCH W/ WITH INCL INCLUDE W/O WITHOUT INSUL INSULATION WALLCOVERING WD WOOD INT INTERIOR WSBF WASHINGTON STATE BARRIER FREE JT JOINT . 11 10 l y) t t s) \ 2 I I I I I 1 1 1 I \ 1 4 SCOPE OF WORK • SOUTHCENTER CORPORATE BUILDING TU K WI LA, ( 113L� �. S U A R E 1 WASHINGTON ®� E 2 _ __ BLDG 1 PARTIAL FL R T IMPROVEMENT SECOND FLOOR OF AN EXISTING OFFICE SPACE . THE WORK CONSISTS OF DEMOLITION AND CONSTRUCTION OF PARTITIONS, DOORS AND OTHER FEATURES. THERE IS NO STRUCTURAL, LOBBY CORE, OR SHELL WORK. CONSTRUCTION TYPE: TYPE V -B - --- - OQ ` <1 > , O 3 2 SPRINKLERS: SPRINKLERED CORPORATE DRIVE NORTH 0 OCCUPANCY: B - OFFICE 0 Z < I Mid 13AOGNV AREA OF WORK: ±945 SF 8 PARCEL ID: 51- 0599163 Q O 9 7 6 11 - � LEGAL DESCRIPTION : J ® ALL THAT CERTAIN REAL PROPERTY SITUATED IN THE CITY OF TUKWILA, COUNTY OF KING STATE OF WASHINGTON, BEING A PORTION OF THE EAST 1/2 OF THE NORTHWEST 1/4 OF THE SOUTHEAST 1/4 OF SEC. 26, T.23N, R.4E, W.M., AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINING AT THE INTERSECTION OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4 WITH THE WESTERLY MARGIN OF ANDOVER PARK WEST (59TH AVENUE SOUTH), DISTANT ALONG SAID NORTHERLY LINE N88 °05'42"W 1369.34 FEET FROM THE NORTHWEST CORNER OF SAID SOUTH- EAST QUARTER; THENCE FROM SAID POINT OF MARGIN TANGENT TO THE E P PREMARGIN S01°4729"W 451.30 FEET; THENCE COURSE ALONG THE ARC OF A CURVE TO TH RIGHT HAVING A RADIUS OF 50.00 FEET AND A CENTRAL ANGLE OF 90 °6'49" AN ARC LENGTH OF 78.64 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 501.40 SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG SAID PARALLEL LINE N88 °05'42 "W 180.90 FEET TO A POINT ON A LINE THAT IS PARALLEL WITH AND 261.00 FEET WESTERLY OF THE EAST LINE IF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE N01 °47'29 "E 136.00 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 365.40 FEET SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG LAST SAID PARALLEL LINE S88 °05'42 "E 37.50 FEET N TO A POINT ON A LINE THAT IS PARALLEL TO AND 223.50 FEET WESTERLY OF THE EAST LINE OF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE N01 °47'29 "E 100.00 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AN 265.40 FEET SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG LAST SAID PARALLEL LINE N88 °05'42 "W 12.50 FEET TO A POINT ON A LINE THAT IS PARALLEL TO ND 2 36.00 FEET WESTERLY OF THE EAST LINE OF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE N01 °47'29 "E 265.40 FEET TO A POINT ON THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG SAID NORTHERLY LINE S88 ° 05'42 "E 206.00 FEET TO THE POINT OF BEGINNING AND CONTAINING 2.408 ACRES OF LAND MORE OR LESS. APPLICABLE CODES: - ,E -EXIT (TD) TRAVEL DISTANCE b V] = - ®- A -` e M I N KLER BLVD. NORTH EXISTING CORRIDOR L \ _ _ _ _ _ _ - - 1 SITE PLAN NTS O O � � 1 I L , 1 1 1 1 I / • • I ,p ' / L (Cp) COMMON PATH I I 105 `� /J► �� a > ` r ¢ Q a STRAN I ER BLVD. INTERNATIONAL BUILDING CODE, 2006 EDITION, AS ADOPTED BY THE STATE OF WASHINGTON. INTERNATIONAL FIRE CODE, 2006 EDITION, AS ADOPTED BY THE STATE OF WASHINGTON. INTERNATIONAL MECHANICAL CODE, AS ADOPTED BY THE STATE OF WASHINGTON. INTERNATIONAL PLUMBING CODE 2006 WASHINGTON STATE I ENERGY CODE (WSEC), WAC 51 -11 WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE (WSVIAQ) PROJECT DIRECTORY . E i EXIT w > z - - MINK • LONGEST TRAVEL DISTANCE =151' • COMMON PATH OF TRAVEL= 54' -8" OCCUPANT LOAD: AREA OF WORK • NO CHANGE OF USE • NO CHANGE OF OCCUPANCY • NO CHANGE OF BUILDING AREA • NO STRUCTURAL WORK • NO CORE/SHELL WORK • NO EXTERIOR WORK ii w z w = - R E SITE � LVD. 945 SF @ 1:100 = 9 OCCUPANTS 1 EXIT REQUIRED, EXIT PROVIDED OD C BUILDING 0 5 1C 2D' NORTH UPLAND DR. MIDLAND D . Plan review approval is subject to errors and ontssions. f di Approval of construction furn nts does not authorize the violation of any adopted code or ordinance. Reoerpt of approved Fiel 1 £ is a 1O "�isdged: B / / i ro A-- TRILAND DDR. OWNER: PROPERTY MANAGER: I J MERIWETHER PARTNERS LLC PINNACLE REALTY MANAGEMENT CO. 2ND & SENECA BUILDING 810 3RD AVE. 1191 2ND AVE. SUITE 140 SUITE 1570 SEATTLE, WA 98104 SEATTLE, WA (206) 615 0(P) (206) 903-0668 (FAX) (206) 381 1200 (FAX) CONTACT: TAMARA GENZALE CONTACT: JOEL P. ASLANIAN EMAIL: tgenzale @prmc.com EMAIL: jaslanian @mericap.com SPACE PLANNER: TENANT: NORTH • / Date -2 - C( - ° c " City Of IticulIa BUILDING DIVISION REGt8 -f p AFtC- . �T 2 1 ABBREVIATIONS 3 1 KEY PLAN AND OCCUPANT LOAD CALCULATION. EXITING PLAN. 1/16 " =1' -0" 4 VICINITY MAP NTS METAL STUDS STAGGERED 8' __ "_.-- __,___ REVIEWED FOR �ra CODE COMPLIANCE APPROVED JUL 0 8 2009 I City 0 JIB pp DIVISION I MARVIN STEIN AND ASSOCIATES, LLC HAIR CLUB FOR MEN 2221 5TH AVE. 1515 S. FEDERAL WAY SEATTLE, WASHINGTON 98121 SUITE 401 CONTACT: LISA BOLSTER BOCA BATON, FL 33432 TEL: (206) 441 -1449 CONTACT: JANE DAVIS - EMBER FAX: (206)441-4361 EMAIL: I.bolster@marvinstein.com @ @ -0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12' -0 ". ATTACH TO STRUCTURE ABOVE W/ HILTI POWER DRIVEN FASTENER 3/4" MIN. PROVIDE AT DEMISING AND SOUND PARTITIONS 4' -0 "WIDE ACOUSTICAL CEILING TILES CENTERED OVER PARTITION ABOVE HUNG CEILING. SEISMIC BRACING PER 9/TI -1. SI EOF • ,. : p J CONTINUOUS CEILING GRID - DO NOT CUT. 1/4 NON -COMB. WD FILLER " UNDER MAIN RUNNERS CONTINUOUS CEILING GRID - 5 PROJECT [N F 0 RMAT 10 N /DIRECTORY l[[ l[[ll[[[[[[l � tll�� %[[[[1[1[[1[11[1 DO NOT CUT. 1<7<f1�ZS�fit'«s�f:><f1� • REVEAL (PAINT BLACK) OR - 1 i !!0.7/1111/ f � LINE OF CEILING GRID BEYOND, SEE R.C.P. - : CONT. 'L' METAL TRIM PAPER ; W/ WING 1. CONTRACTOR SHALL PROVIDE ALLWORKAND MATERIALS IN ACCORDANCE WITH APPLICABLE CITY, COUNTY, STATE AND FEDERAL BUILDING AND FIRE CODES. 2. CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN THE CONTRACT DRAWINGS & SPECIFICATIONS. 3. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 4. B/S INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD AS DRAWN AND /OR SPECIFIED IN BUILDING CONTRACT DOCUMENTS. IF NOT SPECIFIED, CONTRACTOR SHALL SEE ADJACENT SPACES FOR EXISTING EXAMPLES AND CONDITIONS. 5, WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED FOR SEISMIC CONDITIONS. 6 ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE ALARM, SPRINKLER AND SECURITY DESIGN SHALL BE PERFORMED BY THE CONTRACTOR. 7. ALL FURNITURE DESIGN SHOWN ON PLANS IS SCHEMATIC ONLY AND NOT IN CONTRACT, UNO. TENANTS FURNITURE VENDOR SHALL FIELD VERIFY PREMISE FOR LAYOUT CONFIGURATION AND CLEARANCES. 8. ALL VOICE/DATA AND CABLING DESIGN SHOWN ON PLANS IS SCHEMATIC ONLY AND NOT IN CONTRACT, UNO. TENANTS CABLING VENDOR SHALL VERIFY TENANTS REQUIREMENTS AND FIELD CONDITIONS. THE CONTRACTOR SHALL PROVIDE ROUGH -IN AS NOTED, COORDINATION AND SCHEDULING FOR THIS PORTION OF THE WORK. 9 THE FOLLOWING DRAWINGS ARE BASED ON ELECTRONIC INFORMATION DERIVED FROM A NUMBER OF SOURCES. WHILE DEEMED RELIABLE, MS&A CANNOT BE HELD RESPONSIBLE FOR INFORMATION FROM OTHERS NOT FIELD VERIFIED OR WHICH HAS BEEN ALTERED BY OTHERS. 10. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING MANAGEMENT ON CONSTRUCTION HOURS, PROCEDURES AND METHODS ALLOWABLE IN THIS BUILDING. 11. PROVIDE MS&A WITH THREE (3) SETS OF REPRODUCIBLE PRINTS FOR ALL CASEWORK SHOP DRAWINGS FOR REVIEW & APPROVAL. 12. PROVIDE MS&A WITH THREE (3) SETS OF REPRODUCIBLE PRINTS FOR ALL DOOR HARDWARE , APPLIANCES AND EQUIPMENT SUBMITTALS FOR REVIEW & APPROVAL. 13. PROVIDE MS&A WITH THREE (3) SETS OF FINISH SAMPLES FOR ALL NEW SCHEDULED FINISHES, INCLUDING PAINT, FOR REVIEW & APPROVAL. 14. UPDATE AND DISTRIBUTE A PERIODIC SUBMITTAL LOG 15. CONTRACTOR TO FIELD VERIFY ALL ELEMENTS INDICATED AS EXISTING ON PLANS. 16. DOORS & HARDWARE SHALI. BE REUSED, RELOCATED OR NEW BASED ON AVAILABLITY AND SUITABLITY. 17. ALL HARDWARE SHALL BE TENANT STANDARD FINISH, U.N.O. MATCH EXISTING CONDITIONS. Marvin Ste : LLC planning design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 ® Alli s, SUSPENDED CEILING. r; REVEAL (PAINT BLACK) OR MATCH MATCH EXISTING. 1/8 " BLACK FOAM TAPE HOLD BACK 1/4" FROM ) EXISTING CONDITION. C ) � 31/2" X 25 GA. STL. STUDS @ 24 " 1 'X', j O.C. W/ 5/8" GWB, TYPE EACH SIDE. 1/8" BLACK FOAM TAPE HOLD BACK ; C C :; 1/4" FROM EDGE OF TRACK •' CONT. 3 1/2" x 1 1/4" 25 GA. TRACK • W/ (2) #10 SCREWS @ 24" O.C. EDGE OF TRACK. ) \ ' ( A .^ .; 6" X 18 GA. METAL PLATE BLOCKING @ WALL HUNG ITEMS = , ( a 6 NA u ) ;• ( A . ( J F: � ?: HEAD SECTION THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF V.A.V. BOXES. IF LIGHTING LAYOUT CREATES ES A CONFLICT, NOTIFY MS&A PRIOR TO ANY INSTALLATION. THIS IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED. ALL ASPECTS OF THE DESIGN & CONSTRUCTION OF THE HVAC SHALL BE PERFORMED BY T CONTRACTO RE- CIRCUIT SWITCHING OF EXISTING LIGHTING AS NECESSARY TO COMPLY WITH NEW LIGHTING LAYOUT. CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE TO CURRE CODES AS NECESSARY. RE -USE EXIT SIGNS AS POSSIBLE. THE CONTRACTOR SHALL REPAIR OR REPLACE ALL DAMAGED CEILING TILE AND GRID AS NECESSARY TO MATCH EXISTING ADJACENT UNO. PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT, THE CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, FIRE SPRINKLERS, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS, THE CONTRACTOR IS TO NOTIFY MS&A OF THE CONFLICT(S) SO A NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED. THE CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTING PER CODE. THE CONTRACTOR SHALL PROVIDE AUDIBLE AND VISUAL ALARMS PER CODE. ALL LIGHTING AND CONTROLS SHALL BE B /S, UNO. THE CONTRACTOR SHALL SATISFY THE LIGHTING SPECIFICATIONS BASED ON THE AVAILABLE ELECTRICAL VOLTAGE. CONTRACTOR SHALL COMPLY WITH ALL AUTOMATED SHUT -OFF CONTROLS, SWITCHING, SENSORED SWITCHES, TIMED SWITCHES, AND TESTING AND COMMISSIONING REQUIREMENTS. DOCUMENTS SHOW SCHEMATIC SWITCH LOCATION ONLY. ALL B/S EXIT LIGHTS SHALL BE "LED" STYLE AND LESS THAN 5 WATTS/FIXTURE, UNO. < DRAWN BY: JJ JOB NO.: 99135.170 - C CHECKED BY: LB DATE: 05/07/09 PROVIDE ACOUSTIC GATT ' ' PRI - - - -- ` r - i 3 1/2" x 25 GA. GALV. STEEL STUD @ . , 24" O.C. WITH 518" TYPE 'X' GWB EAC SIDE. "' Y . PLAN VIE LATERAL BRACING TENANT WALLS (NO CASEWORK) INSULATION BETWEEN STUDS AT SOUND AND DEMISING PARTITIONS, ONLY. SCALE: AS NOTED NTS 8'MAX 8'MAX 8'MAX 8' 8'MAX REVISIONS /ISSUANCE: 8'MAx ,r }, j, }, 1, y 2'MAX �, �I 1 'i 'I �I 1 NO. REVISIONS INDICATED THUS n DATE <- I NA1 5/8" GWB, TYPE 'X' EACH SIDE, TYP. L ATERAL BRACING PER DETAIL ABOVE (TYP.) pfr �: �' BASE, AS SCHEDULED. NOTES: CONT. 25 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS REQ'D. HILTI POWER DRIVEN FASTENER 3/4 "MIN. EMBEDMENT. BASE SECTION 1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FT. LONG. 2. TEMPORARY ATTACHMENT OF PARTITION TOP TRACK TO THE GRID IS PERMITTED TO ALIGN AND SET THE WALL UNTIL PERMANENT BRACING IS PROVIDED. REMOVAL OF THE TEMPORARY HOLDING SCREWS IS UP TO THE DISCRETION OF THE SPECIFIC LOCAL BUILDING OFFICIAL. CONTRACTOR TO VERIFY. 3. PROVIDE BRACING AT ANY PERMANENT PARTITION THAT IS NOT ATTACHED TO CEILING GRID. 1 . 7 NA 8 PARTITION HEAD BRACING DETAIL 1- 1/2 " =1' -0" 9 B/S TENANT PARTITION 1- 1/2 " =1' -0" 101 LIGHTING NOTES 11 GENERAL NOTES DOOR NUMBER TI -1 COVER TI -2 DEMOLITION TI -3 CONSTRUCTION TI-4 REFLECTED TI -5 ELECTRICAL/ TI -6 FINISH] TI -7 ENLA . RECEIVED t HAY 2 2 2009 SHEET AND DETAILS PERMIT CENTEE PLAN PLAN CEILING PLAN COMMUNICATIONS PLAN 1 PLAN GED PLANS, SECTIONS AND ELEVATIONS I D 0 ci... 0 8 3 TENANT: HAIR CLUB FOR MEN TYPE OF DOOR EXISTING B/S CEILING GRID AND TILE TO REMAIN A. B/S 3' -0" WIDE SOLID CORE WOOD DOOR IN B/S FRAME. TO MATCH EXISTING B/S WALL MOUNTED CABLE OUTLET EXISTING B/S CORRIDOR PARTITION 1 1 EXISTING B/S 2' - 0" x 4' - 0" RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN no . B. NOT USED. L,..---1 1 - N NEW OR RELOCATED B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE 1 EXISTING 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO BE REMOVED /RELOCATED - - -, 0 B/S EXIT SIGN (DIRECTIONAL WHERE SHOWN) ® NEW EXHAUST FAN Q EXISTING RECESSED FLUORESCENT WALL WASH LIGHT FIXTURE TO REMAIN 0 EXISTING RECESSED FLUORESCENT DOWNLIGHT FIXTURE TO REMAIN 0 B/S RECESSED FLUORESCENT DOWNLIGHT OR WALL WASHER FIXTURE TO BE REMOVED /RELOCATED • B/S LIGHT TO BE UPGRADED FOR EMERGENCY LIGHTING. EMERGENCY LIGHT IS CONCEPTUAL ONLY. ELECTRICAL CONTRACTOR TO PROVIDE DESIGN. '1' NEW MIDMARK 355 LIGHTING SYSTEM O B/S COREDRILL NEW B/S CORRIDOR PARTITION TO MATCH EXISTING C. 3' - 0" WIDE SOLID CORE WOOD POCKET DOOR IN WOOD FRAME, TO MATCH EXISTING, W/ METAL TRACK & HARDWARE -� B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET * B/S WALL MOUNTED FOURPLEX ELECTRICAL OUTLET EXISTING B/S TENANT INTERIOR PARTITION TO REMAIN - - - -- EXISTING CONSTRUCTION TO BE DEMOLISHED - - - -- -"-'-'--'' 6" UNLESS OTHERWISE a. BIS LATCHSET NOTED b. B/S LOCKSET c. B/S PRIVACY LOCK d. B/S LOCKSET & CLOSER e. FLUSH MOUNT FINGER PULL AND LOCKSET. NOTES: B/S WALL MOUNTED DEDICATED FOURPLEX ELECTRICAL OUTLET 2OR WALL MOUNTED NEMA 5 -20R DUPLEX ELECTRICAL OUTLET © 18" AFF. NEW B/S TENANT INTERIOR PARTITION: 3 METAL STUDS WITH 5/8" GWB EACH SIDE FROM FLOOR TO UNDERSIDE OF HUNG CEILING, SEE DETAIL 9/T I -1. d NEW MALE INLET HUBBELL WIRING DEVICE - KELLEMS #HBL5278c (OR EQUIVALENT) FLANGED NYLON RECEPTACLE, STRAIGHT BLADE, CURRENT RATING 15 AMPS, VOLTAGE RATING 125 VOLTS, POWER RATING .5 HP. NEMA 5 -15R, 2 POLES, 3 WIRES. EXISTING B/S TENANT DEMISING PARTITION. = - B/S RECITE PARTITION: FULL HT. IN B/S WOOD FRAME WITH SAFETY GLASS WHERE REQUIRED - BUTT JOINT, TYPICAL. SHEET TITLE: SECOND FLOOR COVER SHEET AN D DETAILS SEPARATE 1 B/S WALL MOUNTED COMBINATION VOICE/DATA OUTLET ,,,,,,, PERMIT �ii�A NEW CASEWORK 1. THRESHOLDS AT DOORWAYS SHALL BE 1/4" MAXIMUM IN HEIGHT. 2. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO MATCH B /S. ALL HARDWARE TO BE LEVER-TYPE. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 " MIN. AND 48" MAX. ABOVE THE FLOOR. 3. THE MAXIMUM FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR = 5.0 POUNDS (22.2 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. PROVIDE WALL STOPS (FLOOR STOPS WHERE REQUIRED) AT ALL INTERIOR DOORS. 'N' NEW 'U' UPGRADE EXISTING ' NOTE REQUIRED FOR: 9 A/lechanical Electrical Plumbing Gas Piping '�` ? I City of Tukwila 1 B/S SWITCH (3 =3 WAY) (X= CIRCUIT 'N' NEW 'R' RELOCATED REVISIONS 1 No changes shall be made to the scope of work without prior approval of Tukwila Buildin Division. NOTE: Revisions will re 9 p quire a new Ian submittal and may include additional plan review fees. ALL OUTLETS TO BE MOUNTED 15" A.F.F. - TO BOTTOM OF OUTLET PER W.S.B.F. REQUIREMENTS U.N.O. BUILDING DIVISION ALL DATA & COMMUNICATION LINES TO BE ROUGH -IN ONLY (MUD RING W/ PULL WIRE) REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS&A, IS A VIOLA110N OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2009. T1.1 121 DOOR LEGEND 131 ELEC. /COMMUNICATIONS LEGEND 141 CONSTRUCTION LEGENDS NTS 151 LIGHTING LEGEND NTS 161 DRAWING INDEX OF 7 Cn 01 0 v 0 01 c L_ 0 w CO J U 01 0 0 m n_ 0 0 a o` 0 0 0 Cr 0 c.) 0 N 0 O m I 1 (1 1N c) I m eec U � E 45 —.7= 8 II II � c') m oor F c .. - _ cF-cnox N N.I.0 N.I.0 N.I.0 KEYNOTES: CO .f/- 3'-0" )1 +/- 3'-0" II 1 11 / 11 r 1 1 L - - -J O 1 EXISTING CASEWORK TO BE REMOVED. DEMOLITION NOTES: F = = = 4-1 rt = = � r •rte ��� r \ Y/j � y / 1. DEMOLISH ALL EXISTING FLOORING U.N.O. AND PREP SUB -FLOOR FOR NEW MATERIAL. SEE FINISH PLAN. 2. PROVIDE UNOBSTRUCTED EXIT CORRIDOR AT ALL TIMES DURING DEMOLITION. 3. COORDINATE MPE & FIRE PROTECTION /ALARM SYSTEM DISCONNECTIONS WITH BLDG OWNER & ALL APPLICABLE GOVERNING AGENCIES. 4. ALL DEMOLISHED MATERIAL, FIXTURES, EQUIPMENT, ETC SHALL BE THE PROPERTY OF THE GENERAL CONTRACTOR AND REMOVED FROM THE PROJECT SITE U.N.O. 5. SEE REFLECTED CEILING PLAN TI-4 FOR LIGHTING FIXTURE DEMOLITION. Jr 1/8" =1' -0" DEMOLITION PLAN N.I.0 NORTH 0 5' 10' 20' 30' REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 8 2009 City of Tukwila B UILDING DIVISION 1 bO9 RECEIVED MAY 22 2009 PERMIT CENTER SOUTHCENTER CORPORATE SQUARE BUILDING 1 TUKWILA, WASHINGTON Marvin Ste planning sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: JJ JOB NO.: 99135.170 CHECKED BY: LB DATE: 05/07/09 SCALE: AS NOTED REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS n REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS&A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2009. DATE TENANT: HAIR CLUB FOR MEN SHEET TITLE: SECOND FLOOR DEMOLITION PLAN TI -2 OF 7 c c c " I ( . 4u i 1 I ;;, �, I� ii it UNISEX ( BRAILLE ( 8 0 CO N 0 0 U i N O U N) _C CO 2) I CD I M CO CO I N cngy U 0 I cn : cD o of oF-cnox 2. INSTALL ALL TENANT PROVIDED APPLIANCES. CONSTRUCTION NOTES: 1. ALL EXISTING DOORS ARE TO REMAIN, U.N.O. 3. PROVIDE UNOBSTRUCTED EXIT CORRIDOR AT ALL TIMES DURING TENANT IMPROVEMENT. CONSTRUCTION KEYNOTES: O CONTRACTOR IS TO PROVIDE ACOUSTICAL BATT INSULATION IN ALL WALLS SURROUNDING NEW RESTROOM. O CONTRACTOR IS TO BUILD WALL OUT TO 5' THICKNESS TO ACCOMMODATE RECESSED DISPENSER. SEE ENLARGED PLAN 1/TI -7. O CONTRACTOR TO LOCATE NEW DOOR (HINGE SIDE) MINIMUM DISTANCE FROM COLUMN. 0 CONTRACTOR IS TO SUPPLY & INSTALL NEW WALL MOUNTED METAL COAT HOOK AT 5'-6" AFF, IN CENTER OF WALL. PETER PEPPER, 208 4XL -AL O CONTRACTOR IS TO SUPPLY & INSTALL (4) NEW P -LAM LOCKERS. IDEAL LOCKERS, IMAGE 1000 SERIES, ITEM B (STANDARD 2 TIER. 12 "W/18 "D172 "H), (CH) CONCEALED HINGE, KEYED LOCK, RECESSED HANDLE, FINISH TO BE DETERMINED. O CONTRACTOR IS TO SECURE TENANT PROVIDED SAFE TO WALL. 0 7 CONTRACTOR TO INSTALL TENANT PROVIDED PROCEDURE CHAIR. VERIFY LOCATION WITH TENANT. 0 CONTRACTOR IS TO INSTALL TENANT PROVIDED WALL BRACKET FOR TENANT PROVIDED TV & DVD PLAYER. EXAM EXAM NTS CONSTRUCTION PLAN 1/8" =1' -0" 0 5' 10' DOOR SIGN A. DOORWAYS LEADING TO UNISEX RESTROOMS SHALL BE IDENTIFIED BY A TRIANGLE INSCRIBE IN A CIRCLE 12 INCHES IN DIAMETER. B. BACKGROUND COLOR: BLUE FIGURES: WHITE (COLOR TO BE NON -GLARE FINISH). C. MOUNTING HEIGHT: CENTER OF SIGN TO BE 5' ABOVE THE FLOOR ON DOOR. D. HEIGHT OF LETTERING 5/8" MIN TO 2" MAX. E. MOUNTING METHOD: DOUBLE STICK FOAM TAPE, SCOTCH BRAND 3M. F. THICKNESS: 1/4 INCH. G. FABRICATION METHOD: NEW PLEXIGLAS SIGN WITH SUBSURFACE GRAPHICS AND BACK SPRAYED. H. APPLICABLE CODES: - CAL. TITLE 24 SECTION 1115B.5 - ADA SECTION 4.30.4 UNISEX LAVATORY DOOR SIGN 20' NORTH 30' EASED EDGES, TYPICAL NTS WALL SIGN REMWEp FOR CODE COMPLIANCE APPROVED JUL 0 8 2009 City of Tukwila BUILDING DIVISION A. 1/32 INCH RAISED SANS -SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILE, CHARACTERS MIN. 5/8 INCH HIGH. B. COLOR: BACKGROUND: BLUE TYPE/FIGURE: WHITE (COLORS TO BE NON -GLARE FINISH). C. MOUNTING HEIGHT: CENTER OF SIGN TO BE 5 FEET ABOVE THE FLOOR ON THE WALL - LATCH SIDE. D. MOUNTING METHOD: DOUBLE STICK FOAM TAPE, SCOTCH BRAND 3M. E. THICKNESS: 1/4 INCH. F. FABRICATION METHOD: NEW PLEXIGLAS SIGN WITH SURFACE GRAPHICS AND BACK SPRAYED. G. APPLICABLE CODES: ADA SECTION 4.1.2, 4.30.4, 4.30.5, 4.30.6 CAL. TITLE 24 SECTION 1117B.5 UNISEX LAVATORY WALL SIGN tOo83 RECEIVED HAY 22 2009 PERMIT CENTER SOUTHCENTER CORPORATE SQUARE BUILDING 1 TUKWILA, WASHINGTON Marvin Ste sociates, LLC planning design P g n g 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: JJ JOB NO.: 99135.170 CHECKED BY: LB DATE: 05/07/09 SCALE: AS NOTED REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS n REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS&A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2009. DATE TENANT: HAIR CLUB FOR MEN SHEET TITLE: SECOND FLOOR CONSTRUCTION PLAN TI -3 OF 7 1 \HAIR CLUB FOR MEN\2009\Working Drawings\HCM—PL-02(TI-3).dwg 0 0 0 crs O 0 U N N 0 "`t (1) O rn - _0 m NI 2 cp CM 0 CO CD —. N U1- ¢ E� cn � 0 II c .. �Eoo� 0} —wL CEILING NOTES: 1. SEE DETAILS ON COVER SHEET FOR SEISMIC AND CEILING SUPPORT INFORMATION. 2. CONTRACTOR IS TO VERIFY THAT ALL FLUORESCENT LIGHT FIXTURES ARE EQUIPED WITH PARABOLIC LENSES AND UPGRADE AS NECESSARY TO MATCH. 3. REMOVE EXISTING LAMPS FROM ALL 2'X4' LIGHT FIXTURES AND INSTALL ALL NEW TENANT PROVIDED LAMPS: DURO -TEST, VITA LITE, FLUORESCENT @ 32 WATTS PER LAMP. t ' MECHANICAL VENTILATION SHALL BE PROVIDED BY A METHOD OF SUPPLY AIR AND RETURN OR EXHAUST AIR. PROVIDE A MECHANICAL MEANS OF VENTILATION DURING THE PERIODS OF TIME THE EACH ROOM OR SPACE IS OCCUPIED. THE AMOUNT OF AIR SHALL BE APPROXIMATELY EQUAL TO THE AMOUNT OF RETURN AND EXHAUST AIR. 2006 IMC SECTION 403 & TABLE 403.3. REFLECTED CEILING KEYNOTES: 0 NEW MIDMARK 355 LIGHTING SYSTEM TO BE FURNISHED BY TENANT AND INSTALLED BY CONTRACTOR. COORDINATE LOCATION WITH TENANT. SEE TI -5 FOR ELECTRICAL SPECIFICATIONS 0 CONTRACTOR IS TO PROVIDE & INSTALL NEW MANUAL SWITCH CONTROLLED EXHAUST FAN TO TIE INTO THE BUILDING EXHAUST SYSTEM AND VENT TO THE OUTSIDE OF BUILDING. FAN IS TO RUN AT 400 -600 CMF. 0 CONTRACTOR TO INSTALL TENANT PROVIDED VANITY LIGHT. TOTAL LIGHTING CALCULATION 1 1 V I TOTAL FIXTURES 3 5 O 3 Q 1 12 WATTAGE 288 480 78 26 872 AREA OF SPACE IS 945 SF 945 X 1= 945 WATTS ALLOWED TOTAL WATTS PROPOSED WATTS IS UNDER WATTAGE ALLOWED ( i ° 118" =1' -0" N.I.0 ° REFLECTED CEILING PLAN NORTH 0 5' 10' 20' 30' REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 8 2009 City of Tukwila BUILDING DIVISION RECEIVED FLAY 2 2009 PERMIT CENTER SOUTHCENTER CORPORATE SQUARE BUILDING 1 TUKWILA, WASHINGTON Marvin Ste planning sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: JJ JOB NO.: 99135.170 CHECKED BY: LB DATE: 05/07/09 SCALE: AS NOTED REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS A TENANT: SHEET 11TLE: HAIR CLUB FOR MEN REPRODUCTION, ALTERATION OR PUBUCA11ON OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS&A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2009. DATE SECOND FLOOR REFLECTED CEILING PLAN TI -4 OF 7 CO 0 0 7 Cr 0 C r_ ) N 0 NO - _C CO 0 N 2 U I CCI CO I (n om �t. NU 0 N-• U T°II oo 0 o 112 c DR- o_ DI —cn 2) CONTRACTOR IS TO RE -USE EXISTING ABANDONED ELECTRICAL BOXES AS IS POSSIBLE. INDICATED BY "BFP ". 4) CONTRACTOR IS TO DEMO ALL BLANK FACE PLATES ON EXISTING OUTLETS, NOT TO BE REUSED. PATCH & REPAIR HOLE TO MATCH SURROUNDING WALL SURFACE. ELEC /COMMUNICATION NOTES: KEYNOTES: 1) CONTRACTOR IS TO PROVIDE ELECTRICAL FOR ALL UNDER CABINET LIGHTING. SEE CASEWORK ELEVATIONS, TI -7. 3) CONTRACTOR IS TO DEMO ALL EXISTING ELECTRICAUCOMMUNICATIONS OUTLETS NOT SHOWN ON PLAN. PATCH & REPAIR HOLE TO MATCH SURROUNDING WALL SURFACE. 0 CONTRACTOR IS TO VERIFY NEW CORE DRILL LOCATIONS AND REQUIREMENTS WITH TENANT 0 INSTALL NEW OUTLETS AT 24" DOWN FROM CEILING GRID. O CONTRACTOR IS TO PROVIDE & INSTALL DEDICATED 20A CIRCUIT (NO GFI) WITH A 5-20R RECEPTACLE FOR THE UPS EQUIPMENT AS SHOWN. CONTRACTOR IS TO PROVIDE & INSTALL A BACK UP BRANCH CIRCUIT FROM THE UPS OUTPUT MALE INLET FLANGE TO THE TENANT PROVIDED MIDMARK LIGHTING SYSTEM ABOVE THE CEILING GRID, SEE TI-4. O CONTRACTOR IS TO PROVIDE & INSTALL BACKUP BRANCH CIRCUIT FROM INLET PLUG TO OUTLETS INDICATED, TO INCLUDE: RECESSED FLOOR RECEPTACLE FOR PATIENT CHAIR AND 2 WALL MOUNTED QUADS. LABEL WALL MOUNT INLET PLUG FLANGE "UPS BACKUP POWER ". NEW OUTLET PLATES SHOULD BE ORANGE OR GRAY, NEMA 5 -15R, AND CLEARLY LABELED "UPS BACKUP POWER ONLY". PROVIDE & CONNECT A STANDARD 3 PRONG EXTENSION CORD FROM EACH DEDICATED UPS INPUT POWER RECEPTACLE TO THE BACKUP POWER INLET WHERE THE UPS WILL BE LOCATED FOR USE UNTIL THE UPS IS CONNECTED. VERIFY THAT ENTIRE NEW BACKUP POWER BRANCH CIRCUIT, INCLUDING LIGHTS (SEE KEYNOTE 4) CHAIR & RECEPTACLES IS FUNCTIONAL. 0 PROVIDE B/S JUNCTION BOX FOR TENANT - PROVIDED VANITY LIGHT. ELEC /COMMUNICATION PLAN 1/8" =1' -0" 0 5' 10' 20' NORTH 30' REVIEWED F OR CODE C t�E AP PROVED JUL 0 8 2009 g City of Tukwila DIVISION 3 RECEIVED MAY 222009 PERMIT CENTER SOUTHCENTER CORPORATE SQUARE BUILDING 1 TUKWILA, WASHINGTON Marvin Ste planning sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: JJ JOB NO.: 99135.170 CHECKED BY: LB DATE: 05/07/09 SCALE: AS NOTED REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS A REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS&A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2009. DATE TENANT: HAIR CLUB FOR MEN SHEET TITLE: SECOND FLOOR ELECTRICAL/ COMMUNICATIONS PLAN TI -5 OF 7 FINISH SCHEDULE . SYMBOL/NO. DESCRIPTION MANUFACTURE STYLE COLOR/FINISH MODEL SIZE CONTACT NOTES CARPET J &J N4120 CONNECT 1746 KNOT NA NA NA TENANT PROVIDED, CONTRACTOR INSTALLED. CPT -1 VINYL COMPOSITION TILE TOLI LINOTESTA #522 NA NA NA NA VCT -1 LUXURY VINYL PLANK BURKE MERCER 7102 BLONDE OAK NA NA NA TENANT PROVIDED, CONTRACTOR INSTALLED. VP -1 CERAMIC TILE CROSSVILLE A876 TRUFFLE NA 3X3 GROUT: MAPEI - #35 NAVAJO BROWN NA CT -1 CERAMIC TILE CROSSVILLE A291 PEPPER QUARTZ NA 3X3 GROUT: MAPEI - #35 NAVAJO BROWN NA CT -2 0 GENERAL PAINT BENJAMIN MOORE EGGSHELL FINISH NA 1038 NA NA NA 0 ACCENT PAINT BENJAMIN MOORE EGGSHELL FINISH NA 1067 NA NA NA ® CERAMIC TILE CROSSVILLE A291 PEPPER QUARTZ NA 3X3 GROUT: MAPEI - #35 NAVAJO BROWN NA RUBBER BASE ROPPE P 131 BISQUE NA NA NA NA CD RUBBER BASE ROPPE P198 IVORY NA NA NA NA CED TILE BASE CROSSVILLE A291 PEPPER QUARTZ NA 3X3 COVE BASE GROUT: MAPEI - #35 NAVAJO BROWN NA B -3 CARPET BASE J &J N4120 CONNECT 1746 KNOT NA 4-1/4" TALL NA TENANT PROVIDED, CONTRACTOR INSTALLED. B-4 CD PLASTIC LAMINATE WILSONART 1572 -60 ANTIQUE WHITE NA NA NA NA JZTI N 0 0 0 cc_.) 0 N 0 0 O U M m , Cn N C) CO 07 � Q N ( , �a � 0N--U o IIU- 5ESII of - N.I.0 0 N.I.0 200 N.I.0 X2051 VCT -1 I VCT -1 1 207 1 VP - 1 1 201 1 VCT -1 VCT -1 1 204 1 1 202 1 203 FINISH PLAN 1/8" =1' -0" N.I.0 ° 0 5 10' 20' GENERAL NOTES: NORTH 30' 1) PRIOR TO APPLICATION OF PAINT ALL WALLS ARE TO BE PREPARED FOR A SMOOTH WALL FINISH (LEVEL 4). 2) VCT TO BE LAID IN ONE DIRECTION FOR A MONOLITHIC LOOK. 3) CONTRACTOR SHALL SUBMIT THREE- 8 1/2" X 11" PAINT SAMPLES TO ARCHITECT FOR APPROVAL. 4) CONTRACTOR IS TO PAINT NEW WALLS THROUGH -OUT , U.N.O. TWO COATS OF PAINT OVER PRIMER. 5) CONTRACTOR IS TO PROVIDE TRANSITION STRIPS PER 19/TI -7 FOR CARPET TO STONE TRANSITIONS 6) CONTRACTOR IS TO DIRECT GLUE NEW CARPET WITH NO PAD. 7) CONTRACTOR IS TO PROVIDE TRANSITION STRIP PER 23/TI -7 FOR ALL CARPET TO RESILIENT FLOORING. City of Tukwila BUILDING D►VISIrvg REVIEWE F O R C ODE COMPLIANCE APPROVE JUL 0 8 2009 3 RECEIVED MAY '2 2 2009 PERMIT CENTER SOUTHCENTER CORPORATE SQUARE BUILDING 1 TUKWILA, WASHINGTON Marvin Ste planning sociates, LLc design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 - 1449 DRAWN BY: JJ JOB NO.: 99135.170 CHECKED BY: LB DATE: 05/07/09 SCALE: AS NOTED REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS A TENANT: SHEET TITLE: HAIR CLUB FOR MEN SECOND FLOOR FINISH PLAN REPRODUCTION, ALTERATION OR PUBUCA11ON OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS&A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2009. DATE TI -6 OF 7 C C PLAM CAB. CD WITH LOCKABLE LY WO OD B L • • • G BENIN 1" PL WOOD BLOCKING BEHIND 11 2' -3" S O U T H C E N T E R CORPORATES ARE BUILDING 1 TU K WI L A, WASHINGTON G512 EQISTE�. / / RCHIT- T \/\- __ ___ ������ /, 1, ' ° FACE OF GWB 'NUN .1 79 • : • • _ / � I � • • • : i ` FOR TENANT PROVIDED MEDICINE .� ( r .� \. / CORNER OF GWB WALLS P LAM UPPER CAB. WITH DOORS B ANGLED TI 7 CABINET TO BE INSIDE. , � � AND (2) ADJ. SHELVES. PL -1 M Nip / II II , AA D 2) ADJRSHEB VESITHD OORS � 24 "CLEAR 2 EQ. CASES 1'-8" 1' -0" \ �1= \ � w , ANGLED UNDER - CABINET LIGHTS &APRON &FAUCET. -1 -- UNDER - CABINET LIGHTS &APRON �' / I 1 g^ } WC PLAM UPPER CABS. WITH DOORS AND (2) ADJ. SHELVES. - • -/ / {PAPER 1 , ` SINK INSULATE WRAP @ EXPOSED SUPPLY &DRAIN LINES P LAM COUNTERTOP AND FULL HEIGHTBACKSPLASH. P LAM LOWER CAB. WITH A I TOWEL , I ` DISPENSER \ \ TO 25 "DEEPPLAM COUNTERTOP AN. ULL HEIGHT BACKSPLASH. / E. `' \/ �� - - — UNDER - CABINET LIGHTS &APRON " 25 DEEP PLAM COUNTERTOP AN ULL HEIGHT BACKSPLASH. } 18" 24" AM DOOR TRIM NOTE: W �' r 24° DEEP PLAM �� k � � � � ■ ■■ ■ ■ ■11��. '6 -. \ \ \ I I ' � \ n n LOWER CABS. WITH DRAWERS AND 4 "TOE KICK. NOTE: 5" -3 & FOR ® - - N� �`o - W Lo - \ • • • • • • J ® ■■ ■ 2� CD 25 "DEEP PLAM - t D DOOR, FALSE DRAWER PAN ® ® SEE 2ITI 31TI -3 SIGNAGE LOWER CABS. WITH DOORS, DRAWER, (1) ADJ. SHELF AND 4 "TOE KICK. / 1 ADJUSTABLE SHELF AND 4 " TOE KICK. - PROVIDE FINISHED ENDS AT ALL EXPOSED ENDS. PROVIDE FILLER FOR UPPER &LOWER CABINET \ TOILE PAPER DISPENSER „ _ OPE�N 0 �` 7 ' ' \ \, �/ ,� �` IN / /' - ' f ( AS NECESSARY 2' -0" 1 -0 � , 1 -10 , / \ `\ /, BASE B - 1 / NORTH NORTH ANGLED ANGLED V -6" ANGLED / I � BASE B -1 \� 24" CLEAR,. 5 EQ. DOOKS 1' 2' -0" �, BASE B -1 \i /\________I LED ANGLED \i /\_________I 1 RM 200 ENLARGED FLOOR PLAN 112" =1' -0° 2 RM 200 ENLARGED FINISH PLAN 112 " =1' -0" 3 RM. 202 NORTH CASEWORK ELEV 3/8 " =1' -0° 4 RM. 202 NE CASEWORK ELEV. 3/8 " =1' -0° 5 RM. 202 NORTH CASEWORK ELEV. 3/s " =1' -0" NOTE: PROVIDE FINISHED ENDS AT ALL EXPOSED ENDS. 11 OF GWB UPPER CABS. DOORS (2) ADJ. - CABINET & APRON DEEP PLAM FULL HEIGHT A.N.S.I: APPROVED SINK CABINET WITH : COMPLIANT SINK & . PL -1 DEEP PLAM CABS. WITH (5) AND 4 TOE " PIA FA(F OF PLC 'PER WIl )ORS (2) - TYf UNI CABINET LIG- . - _ &APRO 5" DEEP COUNTERTOP AND FULL BACKSPLASH. NOTE: TI -7 . GWB FACE OF GWB PROVIDE FILLER FOR UPPER & LO LOWER CABINET AS NECESSARY FACE OF GWB g FACE PROVIDE FINISHED ENDS AT ALL EXPOSED ENDS. PROVIDE FILLER FOR UPPER & LOWER CABINET AS NECESSARY 2 EQ. PLAM CABS. I \ , /\ WITH AND— \ �-- -\ . \ __ / / _ LVES, PLAM \ -,- r /z'i AND M SHELVES. UNDER "DEEP �' \./ /� / 1p FACE OF GWB 25" DEEP PLAM PL -1 22" DEEP PLAM COUNTERTOP LIGHTS 25" COUNTERTOP / \ ki / � 22 PLAM COUNTERTOP AND 20 HIGH " ® P TI - 7 P COUNTERTOP AND FULL HEIGHT 9 BACKSPLASH. N AND 20" HIGH BACKSPLASH. N I BACKSPLASH. 10 AND N BACKSPLASH. HEIGHT o N TI -7 P n ^ TI -7 P n r / 25 DEEP PLAM LOWER CABS. WITH DRAWERS n \ BIS PLAM A.N.S.I FAUCET 25" LOWER \ PL P -LAM WALL " MAX. DIM. I --- ` OPEN, / .OPEN . 0 y /R E ' .\ 3' -0" MAX. DIM P LAM WALL MOUNTED ® - EDGE OF WORK TO AL RN PL - -1 - MOUNTED WORK- SURFACE SUPPORTS 3 -0 I f WORK- SURFACE SUPPORT REV IEWE D F R - I � � ' 0 \ _ cJ _ I BIS A.D.A: APPROVED PLAM SINK CABINET @BASE) WITH A.D.A: COMP® SINK & , _ � / - \ I \ .� � .� EQ. EQ. EQ. EQ. I 36" CLEAR I 124" DRAWERS I KICK. EQ. EQ. EQ. EQ. C OD E C OMPLIA f CE � FAUCOTTOM � , 36" / 4 EQ. OPEN 4 EQ. OPEN �® J L 0 XXX 6 3/8" = RM. 205 CASEWORK ELEV 1� -0" 7 D i RM. 204 EAST CASEWORK ELEV. BU IL D G DIVi 1 ° = 1 � -0�� .._ -._. DIN DIV� 10 8 RM. 204 NORTH CASEWORK ELEV 3/8" =1� -0° BIS S.S. FAUCET & SINK PER 25" GA. METAL BACKING PLATE DOORS AND PANELS SHEET METAL SCREWS O.C. INTO STUDS PER DOOR TYP. ADJUSTABLE SHELVES AND APRON PULL FIXTURE PAINTED TYP. SANITARY RECEPTACLE ADA WALL TOILET TOILET PAPER DISPENSER WALL MOUNTED VANITY 6" X 18 ANSI 117.1 CODE COMPLIANCE PLAM BACKSPLASH, HEIGHT VARIES ,? , i I s , ; r � 1 's 25" DEEP PLAM COUNTERTOP OVER 314" MDF / \ PLAM. "' ';151 1 51 ;; GWB CAULK LIGHT FIXTURE. FRAMELESS MIRROR EQ. EQ. 1 NAPKI EQ-4 GRAB BARS EQ -2 39 ^�1 ^ 22" PLAM 1 REAL WOOD EDGING W/ PLAM 1 I r WORK SURFACE -1/2" OVER IT X I \ ;►�; ; ; ; ; ; ; 5 #12 FLATHEAD 1 1 @ 16" 1 , �� ►111 E 6 Q A.D.A.-APPROVED SINK & FAUCET. INSULATE WRAP @ EXPOSED 24" \ 1 1 ^ �:: . FALSE DRAWER FRONT INSULATE ALL EXPOSED PIPES AND HOT SURFACES i E 0 / / Q. \ ,ii tiLvr t • • ► i�• ? ; r I 1 ? 2 HINGES I ,, GROMMET. VERIFY LOCATION /S WITH TENANT. DASHED LINES INDICATE REQUIRED ACCESSIBLE CLEARANCES - 29" MIN. CLR. LL TILE ® n SUPPLY & DRAIN LINES EQ ADA GRAB BARS ZA PLAM. BLOCKING AS NEEDED Marvin Ste �. '. sociates LLC planning design , Seattle, 2221 Fifth Avenue Seattle Washington 98121 (206) 441 - 1449 g 1 `' ) , . ,s: ,,: (2 EA.) ' %' , s i 3/4" PLYWOOD CABINET LINER BACKING rL \ r -2 ''—_ B/S PLAM SUPPORT. CABINET LINER BACKING \ 6" MIN. CL EQ 5 E 3 Q ._._.. ___..______._.__.�._._....._.._ TOILET t-- \ �_ _ N - CF — - - - s z° , CO \ .9b v / CONTINUE FINISH FLOOR BELOW SINK �L! — —'NIP - , EQ -5 TOILET - � _ ` 1 - i z — EQ-3 = PAPER �' DISPENSER M �] J Z _ SHELF N ,_ I\ J / �66 f 1 " 3' �/ DOOR BASE v B -3 ; %, LIGHT \ 7 " \ � \ � °. ,s " 1 % SEAT/ 17" CABINE D OORS ON � B ASE ___ _ -_ /\__ _- FIXTURE 24" A CONCEALED HINGES & TO HAVE FINISH ALL SIDES 9 TYP. WORK COUNTER SEC" 1 =1' -o" 101 A.N.S.I. SINK CASEWORK SECTION 1 " =1' -o" 11 TYP. CABINET SECTION• 1- 1/2 " =1' -0" 12 RM. 200 WEST WALL ELEV. 318 =1' -0" 131 RM 200 WEST WALL ELEV" 3/8 " =11 -0" DRAWN BY: JJ JOB NO.: 99135.170 I 318" MARBLE TILES, 12" X 12' OVER THINSET MASTIC SETTING BED FIXTURE AND ACCESSORY SCHEDULE NOTE: SEE TI -7 FOR EQUIPMENT LOCATIONS CHECKED BY: LB DATE: 05/07/09 SCALE: AS NOTED REVISIONS /ISSUANCE: STAINLESS STEEL SCHLUTER STRIP NO. REVISIONS INDICATED THUS A DATE RECESSED PAPER TOWEL EQ -1 DI MOUNTED @ 48" AFF D DISPENSER OPENING \� `\ .\ / /\ N b /� �N , /� / 7 EASE EDGE & BUTT CARPET TIGHT TO MARBLE EDGE v 1 - CENTER LINE OF DOOR OR DIM. PT. . SYMBOL/NO. MANUFACTURER STYLE DESCRIPTION ARCHITECTURAL TACK STRIP CARPET EDGE COLOR EQ -1 BOBRICK B -43944 CONTURA SERIES, RECESSED PAPER TOWEL DISPENSER & WASTE RECEPTACLE. SATIN STAINLESS STEEL CARPET INSTALLED OVER PAD CARPET STRIP, TO MATCH WALL BASE. r RESILIENT FLOORING OR CONCRETE N.ir Mel WI MI drN'h ?; I III III III III III III III v EQ -2 BOBRICK 6806 SERIES SATIN STAINLESS GRAB BAR WITH SNAP FLANGE. III �� .iii (SUB FEATHERING COMPOUND SLOPED 1 /8" PER FT. TO PROVIDE MIN. 1/8" HT. OVER MARBLE SURFACE FLOOR TO BE LEVELED BEFORE APPLICATION OF FINISH MATERIAL) EQ -3 BOBRICK B-4288 CONTURA SERIES SURFACE - MOUNTED MULTI -ROLL TOILET TISSUE DISENSER. SATIN STAINLESS STEEL. EQ-4 BOBRICK B -270 CONTURA SERIES SURFACE - MOUNTED SANITARY NAPKIN DISPOSAL. SATIN STAINLESS STEEL. BASE EQ -5 KOHLER KOHLER SLOAN K-4302 K- 4670 -C REGAL MODEL 110 ES -S OPTIMA STRATTON WHITE, WATER -GUARD BOWL, ELONGATED, VITREOUS CHINA, FLOOR- MOUNT, 1 -1/2" TOP SPUD. LUSTRA WHITE COMMERCIAL TOILET SEAT SENSOR OPERATED FLUSHOMETER FOR TOILET 14 RM 200 EAST WALL ELEV. 3/8 ° =1' -0" 1 5 FLOORING TRANSITION SEC. DET. 3" =1' -0° 16 FLOORING TRANSITION SEC. DET. NTS TENANT: HAI R CLUB FORME N EQ-6 KOHLER KOHLER K- 2035 -1 K- 7404 -5A WHITE, PINOIR WALL - MOUNTED LAVATORY TRITON CENTERSET LAVATORY FAUCET, POLISHED CHROME FINISH RECEIVED SHEET TITLE: SECOND FLOOR ENLARGED PLAN/ SECTIONS AND ELEVATIONS MAY 22 2009 PERMIT CENTER REPRODUCTION, ALTERATION OR PUBLICATION OF NS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS&A, IS A VIOLATION OF BY MS&A 2009. FEDERAL COPYRIGHT LAW. COPYRIGHT . T1.7 171 ACCESSORY SCHEDULE NA OF 7 i c