Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D09-084 - RANDY'S RESTAURANT - REROOF
RANDY'S RESTAURANT 10016 EAST MARGINAL WAY S EXPIRED 12 -02 -09 D09 -084 City.f Tukwila Parcel No.: 0003400029 Address: 10016 EAST MARGINAL WY S TUKW Suite No: Owner: Name: MICHIGAN PROPERTIES Address: 5301 2ND AVE , SEATTLE WA 98108 Phone: Contact Person: Name: JOHN A STOCKS Address: 30124 126 CT SE , AUBURN WA 98092 Phone: 253 804 -3132 Contractor: Name: NORTHWEST ROOF MANAGEMENT Address: 30124 126 CT SE , AUBURN WA 98092 Phone: 253 - 804 -3132 Contractor License No: NORTHRM927B8 Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: RANDY'S RESTAURANT Address: 10016 EAST MARGINAL WY S , TUKWILA WA $6,138.00 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D09 -084 Issue Date: 06/04/2009 Permit Expires On: 12/01/2009 Expiration Date: 01/28/2010 DESCRIPTION OF WORK: REROOF PROJECT: REMOVE OLD METAL ROOFING AND FASTENER DOWN TO UNDERLAYMENT, REMOVE UNDERLAYMENT BROOM CLEAN AREA, MECHANICALLY FASTEN ONE LAYER OF BASE SHEET ONE INSULATION, AND HEAT WELD (1) LAYER OF MODIFIED MEMBRANE OVER BASE. Fees Collected: $352.65 International Building Code Edition: 2006 Occupancy per IBC: 0004 D09 -084 Printed: 06 -04 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: governing this work will be complie The granting of this pe construction or the p Signature: Print Name: doc: IBC -10/06 City ATukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N Private: Profit: N Private: e not pre ce of wo whether specified herein or not. Permit Number: DO9 -084 Issue Date: 06/04/2009 Permit Expires On: 12/01/2009 Public: Non - Profit: N Public: Date: Al AO I hereby certify that I have read and ned t s permit and know the same to be true and correct. All provisions of law and ordinances me to give authority to violate or cancel the provisions of any other state or local laws regulating ized to sign and obtain this development permit. Date: �O /�`9' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -084 Printed: 06 -04 -2009 • City of Tukwila Parcel No.: 0003400029 Address: 10016 EAST MARGINAL WY S TUKW Suite No: Tenant: RANDY'S RESTAURANT 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 4: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS Permit Number: D09 -084 Status: ISSUED Applied Date: 05/26/2009 Issue Date: 06/04/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Application of roof coverings with the use of an open -flame devices requires a separate permit from the Tukwila Fire Department located at 444 Andover Park East, Tukwila, Washington, 98188; telephone - (206)575 -4407. There shall be not less than one multi- purpose portable fire extinguisher with a minimum 2 -A 20 -B:C rating on the roof being covered or repaired. (IFC 105.6.24, 1417.3) 12: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 13: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 14: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 D09 -084 Printed: 06 -04 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any construction or the perfo :. ce of work. Signature: .i�1 � . ii ✓ Date: Print Name: / �� doc: Cond -10/06 D09 -084 of law and ordinances governing other work or local laws regulating Printed: 06 -04 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hUp..//www.cltukwilawa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 1 //��.. W King Co Assessor's Tax No.: 1 Site Address: I E. M t r3 i is / UAL") !_") Suite Number: Floor: Tenant Name: ?-. w r New Tenant: ❑ Yes N R ; .No Property Owners Name: Mailing Address: CY", / (,, E.. a m4't a irtit ;Ni Li Name: dC4h tZ A SAC .h S Mailing Address: 3 lei_ 1 -) IZ.1.. 11 (1 - S- H:Wpplications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Appbcatior..doc Revised: 1 -2009 bh Building Permit No. 1 Vi Mechanical Permit No. Plumbing /Czar Permit No. Public Works Permit No. (For office use only) r GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping .(pg 5) Contact Person: E -Mail Address: `7'U / t.v t I c City N z� iu � 5r . l� ()a) ern en City Contact Person: Day Telephone: E -Mail Address: Fax Number: State CONTACT PERSON - who do contact when your permit is ready to be issued Day Telephone: 3- & C 3 i 'Z AubuRAJ WA s'Uci 1 ^ City State Zip E -Mail Address: J S i�` Ch�j(Ct� Al al oormar7Q('Cl�) �J j Fax Number: a" a'2J t / ' crn Company Name: Mailing Address: 301/L4 I?-(p -P a - S.F., • MUbo 2 n (_..(1A - ` rr / �� )1 1? 7:Z J 5 i r City State Zip Contact Person: O h r1 3 Day Telephone: 2 3 - 2h i/ -3) 3 - Z E -Mail Address: „1St") 1� � .S Z ti to na y F) Pan/ Fax Number: 253 ° % - 2- `j 3 Lon) Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of. Record . Company Name: Mailing Address: State City Day Telephone: Fax Number: ENGINEER OF RECORD 7 All plans niust be, wet! stamped by:En Company Name: Mailing Address: Zip State 98 i Zi p Zip Page 1 of 6 BUILDING PERMIT INFORMATION * 206 -431 -3670 Valuation of Project (contractor's bid price): $ 6-, .� g, 7 Existing Building Valuation: $ Scope of Work (please provide detailed information): r n, -t ` r r rl - , t ."t ? +� a�.r,a •� �� t^'f �,..r ,., �. t � .,, / e (7/c Y !i ,r PA f ! / Will there be new rack storage? ❑ Yes Number of Parking Stalls Provided: Standard: H:\Applications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application. doc Revised: 1 -2009 bh 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 1st Floor 2n Floor 3 Floor Floors = thru Basement Accessory Structure* Attached. Garage Detached Garage Attached Carport Detached Carport Covered Deck Deck Interior Remodel Addition to Existing Structure Type of Construction per IBC Type of Occupancy pe IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 - 1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On - site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY C : TIFY THAT I . _ D AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY PE • THE LAWS OF _ s ..`111I:�r�%, WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Mailing Address: City Date Application Accepted: a to H:\Applications\Forms- Applications On Line12009 Applications \I -2009 - Permit Application. doc Revised: 1.2009 bh Date Application Expires: ti + Date: Day Telephone: State Zip Staff Initials: Page 6 of 6 'Fixture "Type: Qty Facture Type: . Q .: Filttite .Type:~ : , • :' " Fi . e..Type: := ';Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory ash fountain Receptor, indirect waste Sinks Urinals Wat . Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater : d/or vent Industria aste treatment interceptor, ' eluding trap and vent, exc- ..t for kitchen type grease inte eptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Rep •' or alteration of wa r piping and/or water ' atment equipment Repair or alteratio . of drainage or vent pip ••, : Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacu breakers not included i lawn sprinkler back protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (c tractor's bid price): $ Scope of Work (please pr ide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping H: .pplications\Fonns- Applications On- Line12009 Applications11.2009 Permit Application.doc Revised: 1-2009 bh tlets being Sewer: stalled and the quantity below: Page 5 of 6 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Receipt No.: R09 - 00776 • City of Tukwila Parcel No.: 0003400029 Permit Number: D09 -084 Address: 10016 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 05/26/2009 Applicant: RANDY'S RESTAURANT Issue Date: Initials: JEM Payment Date: 05/26/2009 01:10 PM User ID: 1165 Balance: $0.00 Payee: NORTHWEST ROOF MANAGEMENT TRANSACTION LIST: Type Method Descriptio Amount doc: Receiot - 06 Payment Check 1131 352.65 Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 640.237.114 RECEIPT Total: $352.65 Payment Amount: $352.65 211.00 137.15 4.50 P ' E T ECEIV Printed: 05 -26 -2009 COMMENTS: Type Inspectio ! , e — g.0 rd0 F I,- 6 Je7 I" ei t./ - re dA 1 0J . �- -e J A l� . [�`•r ( lJ 1- n .Q 0 . 1 < -C /L Ge - i--;. i M , 4T :. U ,IE n (`1 __A''I 16 /JJA ( A Jr :( �' �A : r FF r _____ / ..,- - -�-./-J r ► c it\ \ ) - Lre C. t J T IA)) / 0 A '1' I/ S'' 10 At( f , (C.\? Al) (../-4, Lj /0 ail 1 ... 9 Project: . . Q - A - .5 e e . J ( A O Type Inspectio ! , e — g.0 rd0 F Address: , Date Called: Special Instructions: • 7 Date Wanted: '1 G r�.me �' V I P.m. Requester: Phone S3 - i4)4-- ?t 3Z INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit 6300 Blvd., #100, Tukwila, WA 98188 PERMIT NO. P— (206)43 1 -3670 Approved per applicable codes. Corrections required prior to approval. Inspector: 'Date: El $60.00 REINSPECTION FEE REQUIRED -Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 1 Date: March 26, 2009 Submit To: City of Tukwila /Permits Northwest Roof Management Toll Free -1 -866- 610 - 6976 -Fax 253- 939 -2598 As per your request, Northwest Roof Management provided a written narrative of existing roo comprehensive break down for roof removal, new roof material and installation procedures fo Randy's Restaurant 10016 East Marginal Way South Tukwila, WA. 98168 Existing roof deck: Corrugated steel Existing roof insulation 2 "inch Fesco board loose lay. Existing roof underlayment: Two inter plies roofing felt and coated with hot bit Existing metal roof consists of a mechanically attached and interlocked tin shingle (3 CLASS "C" FIRE RATING 'v11 ". 1. Northwest Roof Management shall remove existing built -in gutter system on East side of building only, check for any roof deck deterioration and inform owner of results. 2. Northwest Roof Management shall make any and all repairs to deck defects before installing new gutter system at an additional charge. 3. Northwest Roof Management shall broom and air clean area and dispose of all debris before any new install. 4. Northwest Roof Management shall install new built -in gutter similar in shape and mil thickness. 5. Northwest Roof Management shall remove existing coping and cap metal, store in a safe place and reinstall after roof completion. 6. Northwest Roof Management shall remove existing metal shingles, attached fasteners and built -up two -ply underlayment. 7. Northwest Roof Management shall broom and air clean area and dispose of all debris before any new install. 8. Northwest Roof Management shall remove any wet insulation and make any repairs to deck defects before installing new roof system at an additional charge. 9. Northwest Roof Management shall mechanically attach one layer of #28 base sheets over existing 2" inch fesco board insulation. 10. Northwest Roof Management shall heat weld new Modified Membrane over base sheet. 11. Northwest Roof Management shall heat weld modified membrane flashing into place at all perimeter edges and at curb details. 12. Northwest Roof Management shall clean, bag and properly dispose of all debris. 13. Northwest Roof Management shall supply one bundle of like for like insulation for known (existing) water damaged insulation. Q ED FpF JUN 0 2 2009 Of LDI , Tukwila �N cITY MAY 2 6 2009 PERMRCEId1@R VO1 Johns Manville Description Johns Manville (JM) Fesco Board is a homogenous insulation board, composed of expanded perlite, blended with selected binders and fibers. The expanded perlite contains air cells which provide superior insulating efficiency. The top surface of the board is sealed with a special TopLoc® coating to prevent excessive absorption of asphalt during the installation process. Fesco Board meets the physical requirements of ASTM C 728. Use Fesco Board Roof Insulation is intended for use as a low ther- mal roof insulation board and general purpose cover board for use over closed cell foam insulation boards in BUR, modified bitumen and some single ply roofing systems. Fesco Board can be installed using hot asphalt or mechanical fasteners. It has been rated in numerous FM Global ® 1A -60, 1A -90 and 1A -180 fire and wind - resistant systems and is also approved for use in specific Underwriters Laboratories Inc. Class A constructions and Roof /Ceiling hourly fire -rated (P design) assemblies. Fesco Board has been successfully used in a wide variety of roofing applications for over forty years. MaterplEi INEWEtypoR only when requested on the order, CODE COMPLIANC Typical Physical Properties APPROVED JUN 0 2 2009 City 0 Tukwila Water Absorption, % by Volume - 2 hours 1.5 max ASTM C 209 Compression Resistance 5% Consolidation -psi 30 (207 kPa) ASTM C 165 10% Consolidation -psi 40 (276 kPa) Laminar Strength-psi 7 (48 kPa) ASTM C 209 Flexural Strength -psi 65 (448 kPa) ASTM C 203 Product Density -pcf 9 (144 kg/m ASTM C 209 Linear Expansion 0.5% max. ASTM C 209 For Use over Metal Decks The minimum thicknesses of Fesco Board Roof Insulation over metal decks are as follows: Width of Up to 1° (Max) Up to 1W' (Max) Up to 2 (Max) Rib Opening 12.54 cm) (4.45 cm) (6.35 cm) Thickness (1.91 cm) 1" (2.54 cm) 11/2' (3.81 cm) of Insulation (Minimum) Avoid concentrating loads on insulation. Minimum bearing on flat surface: 2' (5.08 cm). Fesco is not recommended where temperatures are maintained in excess of 200 °F (93 °C). Fesco® Board Energy and the Environment LEED' Recycled Content Postindustrial: Postconsumer: Total: Producing Location: 6)0 2% 28% 30% Rockdale, IL Advantages • Resists damage from construction and maintenance • Excellent substrate for most roofing membranes • Dimensionally stable • Excellent fire resistance • TopLoc coating ensures proper membrane adhesion BUILDING DIVIS ermal Performance Wilma Test Method Thickness C -Value (Conductance) in. cm B1U ir4.1) WAn'•°C 3i 1.91 0.48 1 2.54 0.36 12 3.81 0.24 2 5.08 0.18 2.73 2.08 2.04 2.78 1.36 4.17 1.02 5.56 R - value (Resistance) (In41 nt'•°PJW Sizes Fesco Board is available in 2' x 4' (0.61 m x 1.22 m) and 4' x 4' (1.22 m x 1.22 m) sizes. Other thicknesses available upon request. cxrY MAY 2 6 2009 PERMrTCEPM 0.37 0.49 0.73 0.98 Refer to the Material Safety Data Sheet and product label prior to using this product. RS -5010 5 -08 (Replaces 4-08) 4. POLYGLASS WATERPROOFING MATERIALS AND INSDLATINO SYSTEMS kids vaeme ELASTOBASE° (MODIBASE° or 02 TYPE) MECHANICALLY FASTENED TO ROOF DECK ACCORDING TO FACTORY MUTUAL REQUIREMENTS APPROVED INSULATION APPROVED ROOF DECK/ SUBSTRATE (OR ACCEPTABLE EXISTING ROOF) PART 1 - DESCRIPTION Provide all labor, materials, equipment, supervision and incidentals as needed to install a complete POLYGLASS® reinforced modified bituminous roofing system over a new or accepted, prepared existing roof substrate. All details of installation shall conform to POLYGLASS® Specifications, Details and General Recommendations. QUAUTY ASSURANCE Products used in the work of this Section shall be manufactured by POLYGLASS® or accepted for use in conjunction with the products manufactured by POLYGLASS ®. The Roofing Contractor and his personnel shall be currently accepted by POLYGLASS® as qualified to install the materials of this section. Do not apply roofing during inclement weather. Do not apply roofing membrane to damp frozen, dirty or dusty surfaces. PART 2 - MATERIALS BASE SHEET - ELASTOBASE® base sheet POLYGLASS® SBS (Styrene- butadiene-styrene) modified bituminous base sheet, reinforced with glass fiber mat, 2 mm thick sanded surface (sand backed), and weighing approximately 80 lbs per 200 square foot roll. TRADENAME: ELASTOBASE® ROOFING MEMBRANE - POLYGLASS® APP (Atactic Polypropylene) modified bituminous roof membrane with polyolefin burn-off backing and reinforced with high quality polyester mat. Top finish of the membrane has factory - applied granules (available in a variety of colors) except at selvage edges. This material is packaged in a roll providing approximately 100 square feet of finished roof coverage and weighs approximately 110 lbs. TRADENAME: POLYFLEX® G FR, POLYFLEX® G ASPHALT PRIMER - POLYGLASS® 100A or that meeting ASTM D 41 specification, applied in strict conformance to manufacturers recommendations. 200 SERIES SPECIF CAT DI15 POLYFLEX® G FR, E _ STO ASU ® INSULATED DEC POLYFLEX G FR or POLYLEX G (TORCH APPLIED) COMPLIANC APPROVED UN 0 2 2009 'ty of Tukwila ING DIVISI(` FACTORY MUTUAL APPROVED FASTENERS CflI RSAINALA & FASTENING PATTERN MAY - 2 6 2009 P CSR GRANULE FREE END LAP - Rolls are to be supplie wit free end lap measuring 6" in width. TRADENAME: FASTLAP® INSULATION - POLYTHERM® ISO BOARD or POLYTHERM® COMPOSITE ISO BOARD installed in an approved manner for the application. TRADENAME: POLYTHERM® FASTENERS - Unless otherwise accepted by POLYGLASS ®, fasteners shall be Factory Mutual Approved fasteners and plates. TRADENAME: POLYGLASS® POLYGRIPTM PRODUCT HANDLING All materials, except those that are shop fabricated shall be delivered tot he job site with their original labels intact. Bulk materials shall be identified by the manufacturer as to specification issued. All materials shall be stored in accordance with the instructions of the manufacturer prior to their application or installation. No wet or damaged materials will be used in the application. Materials stored on the job site shall be a minimum 4" off the ground of the roof. Application of all roofing shall be accomplished in such a way that each area will be complete at the end of each day's work. All roof edges and incomplete flashing shall be protected against water entry, particularly between work periods. When ambient temperature is below 40 deg F, care must be exercised in handling and storing POLYGLASS® membrane. Only rolls for immediate application shall be exposed to the elements. All masonry, concrete and sheet metal surfaces incorporated into the roof system shall be primed with asphalt primer meeting ASTM D-41 specification and allowed to dry prior to installing bituminous roofing materials. Wood curbs or nailers, where required, shall be pressure treated with accepted pressure treatment meeting AWAP Standard P-5. POLYGLASS® GUIDE SPEC # 204GF -E POLYFLEV G FR (APP) + ELASTOBASE n0 - 0 $N PART 3 - APPUCATION PREPARATION The roof surface, which is to receive the POLYGLASS® roofing system, shall be smooth, clean, free from loose gravel, dirt and debris, dry and structurally sound. FOR REROOFING APPUCATIONS Remove existing roof flashings from curbs and parapet walls down to the surface of the roof. Remove existing flashings at roof drains and roof penetrations. Remove all wet, deteriorated, blistered or delaminated roofing membrane or insulation and fill in any low spots occurring as a result of removal work, to create a smooth even surface for application of new roof membranes. Existing roof surfaces shall be primed as necessary with asphalt primer meeting ASTM D -41 specification and allowed to dry prior to installing the POLYGLASS® roofing system. INSTALLATION Where a vapor retarder is required by the specifier. Follow the instructions with regard to the particular materials specified and install in accordance with the recommendations of the manufacturer and the requirements of the architect. POLYTHERM ®or other type suitable shall be adhered in accordance with the manufacturer's recommendations. See "General Requirements" section on Thermal Insulation. The insulation shall be mechanically attached directly over the vapor barrier. MEMBRANE Directly over the POLYTHERM® INSULATION install ELASTOBASE ®, with minimum 3" side laps and 6" end laps, without wrinkles or fishmouths. The base sheet shall be mechanically attached, over ISO, to the steel decking. Fasteners shall be per manufacturer specification or accepted subsitute. (see MATERIALS section above) using approximately 25 lbs. per 100 square feet. Directly over the base /ply sheet, torch apply POLYFLEX® G FR. Sheets shall be set with minimum 3" side laps and minimum 6" end laps. Areas of laps where no selvage edge is provided (cut edges, roll ends) shall first have granules heated and embedded into the compound, providing a clean surface for adhesion. The rolled membrane sheets shall be set and unrolled approximately six feet to align sheets. A propane torch flame shall then be applied to the exposed, outer surface of the roll (the membrane underside) until the surface reaches the proper application temperature, generally 350 DEG. F to 400 Degrees F. The roll is then gradually unrolled to create a continuous heat weld between the membrane and substrate. The remainder of the roll is re- rolled and installed in the same manner. There should be approximately ye to 3/8" bleed out of the melted membrane backing adhesive at the overlaps. The laps shall be top rolled using a minimum six -inch wide roller applying pressure over the laps immediately after heat weld is completed. All overlaps shall be checked and sealed. All laps of the underlying sheet shall be checked prior to installing the cap sheet. At all locations where the lap is not sealed, a trowel shall be used to open the lap, heat is to applied with the torch into the lap to melt the adhesive (on the back of the top roll) and seal the lap. Any area where a satisfactory re -weld cannot be achieved shall have a piece welded over it, extending minimum 6" in all directions beyond the unwelded seam. The rolls of membrane shall be installed perpendicular to the slope of the roof, starting at the lowest point of application, wherever possible. Laps of sheets should be installed so as to shed water with the slope of the roof wherever practical. FLASHINGS The flashing shall be installed using POLYGLASS® flashing sheets and minimum 6" wide POLYGLASS® stripping sheets. The stripping sheet shall be installed with a minimum of three inches in both the horizontal and vertical surfaces. The flashing sheets shall be installed with a minimum of six inches on the horizontal surface and extend a minimum of eight inches above the finished roof surface. The flashing sheets shall be installed by the same application method used for the roof membranes. In hot mop applications the flashing sheets may be installed by heat weld application provided the proper flashing materials are utilized. The top edge of the flashing sheet shall be secured using a termination bar (only when the wall surface above is waterproofed), or nailed 4° on center and covered with an acceptable counter Hashing. Items related to reroofing operations such as sheet metal gravel stops, roof vents, and similar items shall be incorporated into the new roof system in accordance with the recommendations described in the current issue of the POLYGLASS® "SPECIFICATIONS AND DETAILS" manual. IMPORTANT NOTE: Never use torch or apply torched materials to areas of combustible materials. Any combustible materials must first be overlaid with a protective barrier or alternatively Remove such materials from the location. Use common sense in the application of torches. ALWAYS keep a suitable, prepared, fire extinguisher available at each area where torching occurs. REVIEWED FOR CODE COMPLIANC E AP PROVED JUN 0 2 2009 City of Tukwila BUILDING DIviefru1 POLYGLASS® GUIDE SPEC # 204GF -E POLYFLEX'P. G FR (APP) + ELASTOBASE'"' LEED® Recycled Content Postindustrial: Postconsumer. Total: 2% 28% 30% Producing Location: Rockdale, IL 11 al7 Johns Manville onsct1pr,e . Johns Manville (JM) Fesco Board is a homogenous insulation board, composed of expanded perlite, blended with selected binders and fibers. The expanded perlite contains air cells which provide superior insulating efficiency. The top surface of the board is sealed with a special Toploc® coating to prevent excessive absorption of asphalt during the installation process. Fesco Board meets the physical requirements of ASTM C 728. Fesco Board Roof Insulation is intended for use as a low ther- mal roof insulation board and general purpose cover board for use over closed cell foam insulation boards in BUR, modified bitumen and some single ply roofing systems. Fesco Board can be installed using hot asphalt or mechanical fasteners. It has been rated in numerous FM Global® 1A-60, 1A-90 and 1A -180 fire and wind - resistant systems and is also approved for use in specific Underwriters Laboratories Inc. Class A constructions and Roof /Ceiling hourly fire -rated (P design) assemblies. Fesco Board has been successfully used in a wide variety of roofing applications for over forty years. Material will have UL® labels only when requested on the order. Typical Physi: :i•) t' :�1�•.;::.:. Values Test Method Water Absorption, % by Volume - 2 hours 1.5 max ASTM C 209 Compression Resistance 5% Consolidation -psi 30 (207 kPa) ASTM C 165 10% Consolidation -psi 40 (276 kPa) Laminar Strength -psi 7 (48 kPa) ASTM C 209 Flexural Strength -psi 65 (448 kPa) ASTM C 203 Product Density -pcf 9 (144 kg/m') ASTM C 209 Linear Expansion 0.5% max. ASTM C 209 For Use over Metal Decks The minimum thicknesses of Fesco Board Roof Insulation over metal decks are as follows: Width of Up to 1' (Max) Rib Opening (2.54 cm) Up to lie' (Max) Up to 2e (Max) (4.45 cm) (6.35 cm) Thickness W (1.91 cm) 1' (2.54 cm) 1W (3.81 cm) of Insulation (Minimum) Avoid concentrating Toads on insulation. Minimum bearing on flat surface: 7(5.08 cm). Fesco is not recommended where temperatures are maintained in excess of 200°F (93°C). Fesco® Board • Resists damage from construction and maintenance • Excellent substrate for most roofing membranes • Dimensionally stable • Excellent fire resistance • TopLoc coating ensures proper membrane adhesion 1herrli ;, i'erluroruu,r Thitduress cm 1.91 1 2.54 1Y 3.81 2 5.08 C -Value (Conductance) BRi(hr4f F) WW. 0.48 2.73 0.36 2.04 0.24 1.36 0.18 1.02 Refer to the Material Safety Data Sheet and this product R -Value (Resistance) pv•F.°RIBW nf.°IWW 2.08 2.78 4.17 5.56 037 0.49 0.73 0.98 Fesco Board is available in 2' x 4' (0.61 m x 1.22 m) and 4' x 4' (1.22 m x 1.22 m) sizes. Other thicknesses available upon request. REVIEWED FOR CO DE C OMPLIANCE FOR JUN 0 2 2009 rodu �I prior to using p ity of Tukwila BUILDING DIVI.cinn► RS- 5010 5-08 (Replaces 4-08) JOHN A STOCKS 30124 126 CT SE AUBURN WA 98092 Dear Permit Holder: -or- Bill Rambo Permit Technician File: Permit File No. D09 -084 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Permit No. D09 -084 10016 EAST MARGINAL WY S TUKW In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/02/2009. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/02/2009, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, R CIAJ 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 ® Fax: 206 - 431 -3665 ACTIVITY NUMBER: D09 - 084 DATE: 05 -26 -09 PROJECT NAME: RANDY'S RESTAURANT SITE ADDRESS: 10016 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Division LAAJ Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 le PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP Fire Prevention • IX Planning Division Structural Incomplete Li Permit Coordinator DUE DATE: 05-28-09 Not Applicable No further Review Required n DATE: DUE DATE: 06-25-09 Not Approved (attach comments) DATE: n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status NORTHRM994CN NORTHWEST ROOF MANAGEMENT CONSTRUCTION CONTRACTOR GENERAL UNUSED 2/15/2001 2/13/2002 ARCHIVED QUALIPCO27NL QUALITY PROFESSIONAL CONST CONSTRUCTION CONTRACTOR GENERAL UNUSED 8/13/19988/12/1999 ARCHIVED Name Role Effective Date Expiration Date STOCKS, JOHN A OWNER 01/28/2008 Bond Amount Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 COLONIAL AM CAS &t SURETY OF MARYLAND LPM4077770 02/05/2009 Until Cancelled $12,000.0002/19 /2009 AMERICAN Untitled Page • General /Specialty Contractor A business registered as a construction contractor with L&tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company NORTHWEST ROOF MANAGEMENT 2538043132 30124 126TH CT SE AUBURN WA 98092 KING Individual UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602098816 ACTIVE NORTHRM927B8 CONSTRUCTION CONTRACTOR 1/28/2008 1/28/2010 GENERAL UNUSED Other Associated Licenses Business Owner Information Bond Information https://fortress.wa.gov/lni/bbip/Detail.aspx Page 1 of 2 06/04/2009 i Rahel \ � Res- Or d iocw, K (Aid et viH c9 / IP > &A I ‘e... SEPARATE PERMIT REQUIRED FOR: O Me'chanica! Bectdad Plumbing Gas PAhtg City of Tukwila BUILDING DIVISION Etv ∎ ?m evri l oad City BUILD! kwila Approval of Ooton the violation of any of approved FL A-} R edit nio C ix, cS n ■ : r 't FILE COPY 7idawls DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions w an. may Inc ude additional plan revie f es. t omissions. aloe Receipt R MILA MAY 1 6 2009 RMIT ki I Pi3 ncL S. C `' rh e-tal (Alp Evi? m ateri 0 T�h S1,1;151es l� f ea_. 7 .See.- - it ' on +2." n e /gi co.. 'r ah SAlh3 ©'F r oaf' Knowyt Waier " Sed. 0 No war 1 4 b e. gr rvnecl j �9h Sort ac23 Man:KAIwwcty Fia R e'er(' S1 K ao -P Sloe U i +L" Me4a( c.a,? Tth ,��► 0lies kAor 14 vkie-tcl (41? Rand S Lure( v► /4016 ti4I(J -1 7,KG.J;142. 1 WA 98/68 REVIEW FOR CO DE COMPLIANC APPROVED JUN 0 2 2009 DIIY of Tukwila BUILDING Dltr►pt "A , rc�s e crtY MAY 6 2009 PERMIT CENTER