Loading...
HomeMy WebLinkAboutPermit D09-096 - ARCO AM/PM - TENANT IMPROVEMENTARCO AM/PM 5800 SOTJTHCENTER BL D09 -096 Parcel No.: 1157200352 Address: 5800 SOUTHCENTER BL TUKW Suite No: Tenant: Name: ARCO AM /PM NO 83098 Address: 5800 SOUTHCENTER BL , TUKWILA WA Owner: Name: YAMASHITA SUSIE Address: YOSHINO INC , 5800 SOUTHCENTER BLVD 98188 Phone: Contact Person: Name: ALEXIA INIGUES Address: 18215 72 AV S , KENT WA 98032 Phone: 425 251 -6222 Contractor: Name: JOE PARK CONSTRUCTION LLC Address: PO BOX 527 , YAKIMA WA 98907 -0527 Phone: (509)452 -5122 Contractor License No: JOEPACL994DE Citylk Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us DEVELOPMENT PERMIT Permit Number: D09 -096 Issue Date: 07/20/2009 Permit Expires On: 01/16/2010 Expiration Date: 03/05/2011 DESCRIPTION OF WORK: ENCLOSE 26 SQUARE FEET AND PROVIDE TENANT IMPROVEMENT. WORK INCLUDES DEMOLITION AND REPLACEMENT OF NON -LOAD BEARING WALLS, NEW FLOOR FINISHES, LIGHTING IMPROVEMENTS, NEW CABINENTS AND COUNTERTOPS, NEW FOOD SERVICE EQUIPMENT, NEW GONDOLAS, NEW WALL FINISHES AND PAINTING, UPDATE SIGNS, AND UPDATE EXTERIOR PAINT COLORS. Value of Construction: $125,002.74 Fees Collected: $2,655.09 Type of Fire Protection: NONE International Building Code Edition: 2006 Type of Construction: IIB Occupancy per IBC: 19 doc: IBC -10/06 * *continued on next page ** D09 -096 Printed: 07 -20 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Water Meter: doc: IBC -10/06 City oilkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: N Permit Center Authorized Signature: • / l/�/✓' `� Date: /0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting f •ermit does not presume give authority to violate or cancel the provisions of any other state or local laws regulating construction r tl� • - rform. e of k. I a uthorized to sign and obtain this development permit. Signature: Date: OR 2 -UOF'I Print Name: >. raf..---Q-Likt\J')E 1F-- Permit Number: D09 - 096 Issue Date: 07/20/2009 Permit Expires On: 01/16/2010 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -096 Printed: 07 -20 -2009 Parcel No.: 1157200352 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 5800 SOUTHCENTER BL TUKW ARCO AM /PM NO 83098 PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D09 -096 ISSUED 06/08/2009 07/20/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 D09 -096 Printed: 07 -20 -2009 15: ** *FIRE DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 nun) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 27: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 28: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 29: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. doc: Cond -10/06 D09 -096 Printed: 07 -20 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 30: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 31: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 32: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 34: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 35: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 36: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 37: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** D09 -096 Printed: 07 -20 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction o ,the-aerformance of work. Signature: 60.t Print Name: 4,�� am O eQ..LAKLTbC_ --- doc: Cond -10106 D09 -096 Date: D 2(.0 ) ordinances governing or local laws regulating Printed: 07 -20 -2009 CITY OF TUKWILA) Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwei.tukwila.wa.us SITE LOCATION Site Address: 5800 Southcenter Boulevard, Tukwila, WA 98188 Tenant Name: ARCO AM /PM Facility No. 83098 Property Owners Name: BP West Coast Products LLC Mailing Address: 4 Centerpointe Drive E -Mail Address: ainigues @barghausen.com Company Name:_ Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number. Contact Person: Ms. Caryl J. Mattson E -Mail Address: cmattson @barghausen.com Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Company Name: Barghausen Consulting Engineers, Inc. Mailing Address: 18215 - 72nd Avenue South Contact Person: Jay Grubb E =Mail Address: jgrubb@barghausen.com H:\Applications\Forms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Building Perno. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) Dol'Ton 01,l/ F0 King Co Assessor's Tax No.: 115720 =0352 Suite Number: Floor: New Tenant: 0 Yes ®:: No La Palma City CA State CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Alexia Inigues, Barghausen Consulting Engineers, Inc. Mailing Address: 18215 - 72nd Avenue South Kent WA 98032 Day Telephone: (425) 251 -6222 City State Fax Number: (425) 251 -8782 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) D Ci Day Telephone: Fax Number: Expiration Date: State City State Day Telephone: (425) 251 -6222 Fax Number: (425) 251 -8782 City State Day Telephone: (425) 251 -6222 Fax Number: (425) 251 -8782 90623 Zip Zip Z p ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Barghausen Consulting Engineers Inc: Mailing Address: 18215 - 72nd Avenue South Kent WA 98032 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Zip Page 1 of 6 1975 . 030 . ndf . do< BUILDING PERMIT INFORMIION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 125,000 Existing Building Valuation: $ 420,000 ildi Scope of Work (please provide detailed information): tenant improvement to existing store interior consisting but not limited to demolition and replacement of non -load bearing walls, new floor finishes, lighting improvements, new cabinets & countertops, new food service equipment, new gondolas, new wall finishes and painting, update exterior signs, and update exterior paint colors. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling:_ Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 6 Compact: 0 Handicap: 1 Will there be a change in use? ❑ -- - Yes m No If "yes ", explain. FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets: SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic systefn, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorms- Applications On Line \2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 1975 : 030.pdf.doc Existin• Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 1,800 26 II - B (Store) M 2 Floor 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMIION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 125,000 Existing Building Valuation: $ 420,000 ildi Scope of Work (please provide detailed information): tenant improvement to existing store interior consisting but not limited to demolition and replacement of non -load bearing walls, new floor finishes, lighting improvements, new cabinets & countertops, new food service equipment, new gondolas, new wall finishes and painting, update exterior signs, and update exterior paint colors. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling:_ Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 6 Compact: 0 Handicap: 1 Will there be a change in use? ❑ -- - Yes m No If "yes ", explain. FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets: SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic systefn, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorms- Applications On Line \2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 1975 : 030.pdf.doc PUBLIC WORKS PERMIT INTION — 206 - 433 -0179 • Scope of Work (please provide detailed information): interior remodel only. no new plumbing fixtures, replace and relocate within existing structure. Water District m ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District m ...Tukwila ❑ ...Sewer Use Certificate ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water li:\Applicntions\Fo i s- Applications On Line\2009 Applications \1 -2009 - Permit Application :doe Revised: 1 -2009 bh Call before you Dig: 1- 800 -424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. 0... Valle View ❑ .. Renton ❑...Sewer Availability Provided ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ .. Highline ❑ ...Permanent Water Meter Size::. WO # _ ❑ ...Temporary Water Meter Size .. WO # ❑ :::Water Only Meter Size WO # _ ❑ ...Sewer Main Extension Public ❑ Private ❑ ❑ ...Water Main Extension Public ❑ Private ❑ ❑ :. Renton ❑ :: Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ :. Geotechnical Report ❑ ... Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .: Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless = (SAO) ❑ —Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ :.:Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right= of=way Use - Profit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ .. Right -of -way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way ❑ Non Right -of -way 0 ❑ ...Total Cut _ cubic yards ❑ .. Work in Flood Zone ❑ ...Total Fill cubic yards ❑ .. Storm Drainage ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ :::Deduct Water Meter Size " FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewa Treatment Monthly Service Billing to: Name: - Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip Page 3 of 6 1975; 030:pdf.doc PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules: Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZ AGENT: /, p Signature: ��'® Date: &/ 2 /D J Print Name: _ )1 l V 14 e .s Day Telephone: / Z 257 (!2 Mailing Address: /8" i� A - S• Y WA 9R0 dot City State Zip Date Application Accepted: H:WpplicaiionsWorms= Applications On Linc\2009 Applications \I =2009 = Pcnnit Applicaiion.doc Revised: 1 -2009 bh • • Date Application Expires: I1421) ()e) Staff Initials: Page 6 of 6 1975.030.pdf.doc Parcel No.: 1157200352 Permit Number: D09 -096 Address: 5800 SOUTHCENTER BL TUKW Status: APPROVED Suite No: Applied Date: 06/08/2009 Applicant: ARCO AM /PM NO 83098 Issue Date: Receipt No.: R09 -01131 Initials: LAW Payment Date: 07/20/2009 03:14 PM User ID: 1632 Balance: $0.00 Payee: JOE PARK CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 040556 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://wwwci.tukwila.wa.us Account Code Current Pmts 000/322.100 000/345.830 640.237.114 RECEIPT 1,616.09 567.42 1,044.17 4.50 Total: $1,616.09 Payment Amount: $1,616.09 PAYMENT RECEIVED doc: Receiot -06 Printed: 07 -20 -2009 Parcel No.: 1157200352 Permit Number: D09 -096 Address: 5800 SOUTHCENTER BL TUKW Status: PENDING Suite No: Applied Date: 06/08/2009 Applicant: ARCO AM /PM NO 83098 Issue Date: Receipt No.: R09 - 00847 Initials: User ID: JEM 1165 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Payee: BARGHAUSEN CONSULTING ENGINEERS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 69876 1,039.00 Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES RECEIPT Account Code Current Pmts 000/322.100 1,039.00 Total: $1,039.00 • Payment Amount: $1,039.00 Payment Date: 06/08/2009 04:07 PM Balance: $1,616.09 PAYMENT RECEIVED doc: Receiot -06 Printed: 06 -08 -2009 Project: Project: /9 1 /A 4 Z8.1■0.-11> Type of Inspection: r/AML.- Address: 6 00 /141./TFA BL Date Called: Special Instructions: / Date Wante // a? 4/d S p.m. Request r: Phone No: do5 54 9- . 9 2 yy -It. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Ai( w f / . 1J t z ( Insp ctor: Date: $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3 7 ❑ Corrections required prior to approval. COMMENTS: Type of Inspection: i` i..v 9 / :JD 1■1“:,b A--t■ S yi,;1/4. : 0 \ ,_, ' r . I G -A,/ J( p J: o/ (� I3J.E 1 A r • � J t`, s J f 4Pe (t A I Ay Phone No: -7e) 5'6 S - q241e/ J t'. P ,P • To / c L..0 AA p A.,-" ` ( N _____ „ . Project: ,e)i d f)in /P/1- Type of Inspection: i` i..v 9 / Address: - 8o D ..S /1 rt/ i &- Date Called: Special Instructions: Date Wanted: //— /'- OS p.m. Requester: Phone No: -7e) 5'6 S - q241e/ INSPECTION NO. INSPECTION RECORD Retain a copy with permit ./3615•- asp PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- ❑ Approved per applicable codes. Inspector: f Date: Corrections required prior to approval. $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 6ri 0 Receipt No.: Date: Project: Irw iitik IpM Type of Inspection: G //1 Address: Date Called: Special Instructions: / Date Wanted: / /I' 17 - 0° a.m. ' Requester: Phone No: 42_S -2.4g- Ird INSPECTION NO. INSPECTION RECORD Retain a copy with permit p R PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r* 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Ins ctor: Date: r p- f El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project; - ^ A Jn� (. Type i tIIn �Sti,Qn: J , 4 Address: � sCR JD 0. s Date CaalleddA ' c e. < Special Instructions: / Date Wanted: /t a Requester: Phone No: 47 0 INSPECTION RECORD Retain a copy with permit aoq -dqc PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 A pproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: PA Inspects: Dater 0 $60.00 REINSPECTION FEE R'QUIRED. Prior to inspection,.fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: F ,#1.JTh Aq Ay p3✓A --""- Address: Sao6 ...sor›iI'/r�eev" "ESL )C 6A ' 649 j_tc e J-U i L 1, 44.f A -I C.A- t ,JL& eye .e,..1,, ,, ..j - r - e 9.,‘...T (vr / f) S &...K— - A is o , \, Ttil 1(A-? J A Of k k ^ ,.• J i r e,T l , ,.. -IKG-, Also G, 7 --` ,J , 'r /f 3J J i I n k e Ore-r) Phone No: 1,TO _ 4t - yz 4/ y Project: /9Q eo /9 / Type of Inspection: ,5 (IF /u/ Address: Sao6 ...sor›iI'/r�eev" "ESL Date Called: Special Instructions: Date Wanted` / / /!�/ p .m. Requester: Phone No: 1,TO _ 4t - yz 4/ y INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. Corrections required prior to approval. Inspe Date: - 4- 6 7 s $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: Type of Inspection: c- 2 A Ai ) p et (AM1 t Address: ad-- '5 �Ov SNI. I kc��tp� Special Instructions: /) !( CC-- re l' f. ' r l ((..--J A .( t j J C G'' Requester: . : C. 1: 4 j Phone No: t '(7), c-- S /1-n 6 o /--t v LL-- /-,/ ek » . ,, At. ) I ,'As Jt M 23A )C A ( j i; / o f -A 4. JA • ! l is e. P Project: Type of Inspection: c- 2 A Ai ) p et (AM1 t Address: ad-- '5 �Ov SNI. I kc��tp� Date Called: v � A �� J n Special Instructions: Date Wanted: Ira la- i (oar a.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit pO (-- INSPECTION k10. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. Corrections required:prior to approval. Inspe tor: Date: 0- 2( 7 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call tdschedule reinspection. Receipt No.: Date: Project: / A-2.w #� / /Pil Type of Inspection: f J 4M e'- W' t I -r-AS. - A (Zo()F -c-"s 4.) Ali- Ad d re s s : 3 O SC 64vi Date Called: Special Instructions: _ Date Wanted: I D i' 61-3 a �p.m. Requester: Phone No: ti 64` (4 -- 4 2 44 El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 orrections required prior to approval. COMMENTS: yy l.--0 n b 4. U /' r( A e 4 CA'AZ,&ag‘i Inspe( tor: Date: I '(q'b q ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: Type of Inspection: 200E 5Le; :4 � Address: 5800 s-c. 3 too . ar� L , � p R .b S t d &.) pr a ha- o u-CI ` ne r eSWOo 0 Requester: ' J}4 -;r+ -9 /JJAf 44 1 - ‘‘Ai Oef I ,J 0417 . 3 1 Project: Mit AT C.‹) /pi Type of Inspection: 200E 5Le; :4 � Address: 5800 s-c. 3 too . ar� Date Called. �� �^q— Special Instructions: / Date Wanted: i 14' / p.m. Requester: Phone No: cog - qc9 - 4244 4: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. U Corrections required prior to approval. El $60.00 REINSPECTION FEE REO RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedutg reinspection. Inspe Date: ' J-0'/-4"M Receipt No.: 'Date: /J� Prill&O A k jA Type of Insp}ecttipn: f / . • Address: 4 k ov s� gv , Date led: Special Instructions: / Date Wanted: / a.m. Requester: Phone 05 q 244 -� INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION } - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 COMMENTS: ems Inspec or: Date: Approved per applicable codes. Co ecti. s . uire ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. pproval. (Receipt No.: 'Date: n Projct: G O AAA / P � r Type of Inspect_ n: , \ ^' Address: L, / 0 ' Date Called: Special Instructions: Date Wanted: .., "" ( -d 1 p.m. Requester: Pho a: _ C(0 q 4241 #z- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION " t' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: DA.rt4 A - 4 OA ( �, Li C,<)- cJA /h A 3I. Insp I Date: I ( $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: 'Date: COMMENTS: �,.- i 1. I l A- c4.�tc eUe C cv) p •\ DI- e e5T 4 ' v) e —54.r 47 - , IS e Yfrp r ' ,uLi l . gL. cE" , )1 — A 71/ J,ie'A , )/1 5 I. i 6;14 (.....,. /--- Date Wanted: 5 - Requester: Phone No: 11 A Project: /9 h?G�CJ /107/PW Type of Inspection: • /- �IUT /�t/4, ft SGt -h- . i Address: 'goa SGD/4 / . gL. Date Called: Special Instructions: Date Wanted: 5 - Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTIIN NO. CITY OF TUKWILA BUILDING DIVISION vo9•-oq6 PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. corrections required prior to approval. ` Inspegtor: Date: Q El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: h Project: »g 4frvi PM Type of Inspection: Fire Alarm; \._, Address: ; zfackp Suite #: . 2--, c-, ry,,q1 / Contact Person: ,,pia , a . 4),10rr Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm; Hood & Duct: - Monitor: Pre -Fire: ./ Permits: Occupancy Type: 2 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila Wa. 98188 206- 575 -4407 [ proved per applicable codes. n Corrections required prior to approval: COMMENTS: I 7 _ 3 ,1 ) p/oli PERMIT NUMBERS 'Inspector: 5) s Date: .l �Jl 9,�c► Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will. receive an invoice from t e City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D.pForm F.P. 113 • .+ - lonv •rr •.. - T" -. — .a•+vmv.. Food Establishment Inspection Report Form C Prz_ 000t-N Business Name: Operator: Page 111.41RC16 ;t? TiM111 SOu 474 Er r " t�:1 n IV1c� ( f� tt2 - �ty, Tt1v/ S'L1SIr - D�..•� I Phone: Address City ZIP Seats / Checkouts $'S0'_`0.&- o:� al5. General Health Record ID Item Number P/E 1 O11 fv Y,o Q.1 Date Time In OBSERVATIONS and. CORRECTION ACTIONS Violations cited in this area must be corrected with the time frame specified. - Prc o pe /Gher insl,P< ( Re A^odr I Points jt,r_w)1h l &5 (j / t !>se It`e r rw r- (%) / N . e r . ^ o h ''<'"C ( 4 1 4 , A 1 ►-p F, )- fM 1'tn C , wr t - c / t - se vp is 1ollo �lrs r Y' 1, /1 wr Oh 1'(re.S1Hr•A1 ^S 0(11 l 4St �I cuct1W4Jf^ k' < /wtfrl (n..l;n 1" �6 lrtri J 1. = rthc_ ( (last et, ecse (l,S /70v•SI- I0(1,1 -eA ih roc Isl.,1 (^)r F(e. OcesteA ('(„ n / 1,.f r h 11 wltl . lo(N■ , . ov , the ItW /e hcl.r••5 V F(.(04.1 191.0 11- A((( c�P,�^rrl PI(,r,$ G r �trl can J•,I. (1) r1, 41 � 1, � ,,l�,r S p /w.l><- PC,D1 _ oS11 (� � �t,N� li Ike (fh/ o } 1.. It.✓,Iti ey1 ti it D / D C ) All k6,...,,St•,lr_3 al,i14 IUU'1' Snr,, ptiyai to�tS U S p ► 1 (( .�P /)11 Uv.l�> Wn(G o 4 l ur 1 > e `II i , l rk r lc r S p /C P re . ( tnl�' 1 tw1 D P ♦ M -T N � ..t_ . 1 0 - l lA(((.l I y 1.kS A ?P/ r-' ", NJ (3) C-1 C.. ‘,)re p, (t(i- Employees must have a valid food Comma worker's card within 14 days of hire. Please call 206- 296 -4791 for more information. ((^ /.ti 5c. d6 UJN ° /S p (2ob )245 -7S Office Time Activity Time Travel Time m m : m f(r • ATTENTION We only approve your application for a permanent food service establishment from the Department of Public Health Seattle & King County. Other permits and inspections may be required by other agencies. Operating this establishment without these permits and inspections may result in legal action by the appropriate agencies. Based on an inspection this day, the above items are violations, which must be corrected in the time specified by the health officer. A food establishment permit may be suspended without warning, notice or hearing if the requirements of the food code and/or directives of the health officer are not met or if violations are not corrected in the time stated in this report. The permit will be suspended if an imminent hazard exists or there are 90 or more red critical points or if there are 120 or more)otal points. The health officer will provide an opportunity for an appeal on the validity of a suspension or the findings of an inspection report if a written request is filed with the health officer within ten (10) days of the suspension or inspection.The filing of an appeal does not stay the effectiveness of a suspension.The completed inspection form is a public doc}iment that must be made available to any person who requests it under the provision of the Public Disclosure Act (42.17.260 RCW). of Red Critical Points N A Service 128O Scheduled 129 ❑Return 126 ❑ Fld PI Rvw 130 Complaint 1330 Illness / Inj. 134 ❑Permit Inv. 136 ❑ Field Educ. 127 re- Operat. 1060 HACCP Results 01 ❑ Satisfact 02 ❑ Unsatisfact. 03 Complete 04 [] Incomplete Action 04 ❑ Suspend 07 RI Approved 10 ❑ Disapprv'd 26 ❑ FoVup Rq'd Trans Fat 7130 ❑ May 2008 7140 ❑ Feb 2009 7150 ❑ Documnts Nutrition Labeling 7200 ❑ Applies 7220 ❑ Menu 7230 ❑ Menu Bd 7240 ❑ Pt of Order 7250 O Statement 7260 ❑ Review Blue Points Total Points N A Person in Charge (Printed Name) 0.. ^ \. e v (Signature) \ Regulatory Authority (Printed Name) s A c rl o c (Signature) D14_no - A_1 lGnv 11 /f1R1 Vb�'aile � Public Health Seattle & King Coun Bill Rambo, Permit Technician City of Tukwila Community Development 6300 Southcenter Boulevard, STE #100 Tukwila, WA 98188 RE: Response to Comments Permits #PG09 -057 / #M09 -066 / #D09 -096 / PW Comments ARCO AM /PM Interior Retrofit 5800 Southcenter Boulevard, Tukwila, Washington ARCO FAC No. 83098 (6155) / Our Job No. 1975.75 Dear Bill: • • July 8, 2009 CIVIL ENGINEERING, LAND PLANNING, SURVEYING We have revised the plans and technical documents for the above - referenced permits and in accordance with the comment letters listed below. Although no revisions were required for the Electrical plans (El.1- El .4), we are submitting two (2) complete revised sets of those as well due to other department reviews. Accordingly, enclosed are the following documents for your review and approval: 1. Plumbing Review: f(11)1-1)C 1 a) Two (2) REVISED Plumbing Drawings sheet P1.1 b) One (1) City of Tukwila Revisions Submittal Cover Sheet for PG09 -057 c) One (1) copy of Plumbing Permit Correction Letter #1, dated June 18, 2009 2. Mechanical Review: MO° a) Two (2) REVISED Mechanical Drawings sheet M1.1 b) One (1) City of Tukwila Revisions Submittal Cover Sheet for M09 -066 c) One (I) copy of Mechanical Permit Correction Letter #1, dated June 15, 2009 3. Development / Building Review: 0001 -VoK, a) Four (4) complete REVISED Building Plan Sets b) One (1) City of Tukwila Revisions Submittal Cover Sheet for D09 -096 c) One (1) copy of Development Permit/ Building Correction Letter #1, dated June 2009 4. Public Works Review: PV+0 1- a) Four (4) Plan Sheets for Installation of Reduced Pressure Principle Assembly (RPPA) sheet AU 1.1. 18215 72ND AVENUE SOUTH KENT, WA 98032 (425) 251 -6222 (425) 251 -8782 FAX BRANCH OFFICES • OLYMPIA, WA • TACOMA, WA • CONCORD, CA • TEMECULA, CA www.barghausen.com Bill Rambo, Permit Technician July 8, 2009 City of Tukwila Community Development -2- b) One (1) Type C Permit Fee Construction Cost Estimate for Backflow Installation, prepared by a licensed Engineer (sealed) c) One (I) copy of Public Works Request for compliance with cross- connection control program The following outline provides each of your comments in italics exactly as written, along with a narrative response describing how each comment was addressed: Plumbing Comments: June 12, 2009 by Allen Johannesson, Plans Examiner (206) 433 -7163 I. The door opening into the bathroom in front of the sink does not meet accessibility for 60 inch minimum maneuvering clearances at doors. Also doors shall not swing into the clear flood space of any fixture. Please revise the floor plan for the bathroom where the door and fixtures shall be placed to meet accessibility clear floor space and maneuvering requirements. (ANSI 404.2.3 & 1004.11.1.1) Response: Interior door to restroom has been reduced to 34" wide, lavatory has been rotated and new exterior wall was pushed out a few inches to accommodate the required space, see sheet A1.1. Mechanical Comments: June 10, 2009 by Allen Johannesson, Plans Examiner (206) 433 -7163 1. Makeup air shall be required for the new Type II duct. Makeup air shall be supplied during the operation of commercial kitchen exhaust systems that are provided for commercial cooking appliances. The amount of makeup air supplied shall be approximately equal to the amount of exhaust air. The mechanical makeup air and exhaust system shall be electrically interlocked to ensure that makeup air is provided whenever the exhaust system is in operation. The amount of makeup air shall be approximately equal to the amount of exhaust air and not reduce the effectiveness of the exhaust air. The temperature differential between makeup air and the air in the conditioned space shall not exceed 10 degrees. Identify provisions on the plan with relative documentation for a makeup air system that is electronically interlocked with the new Type II hood (IMC 508.1 & 508.1.1) Response: The existing mechanical units are providing outside air. The outside air will be used as make -up air for the "Type II" exhaust hood fan. (Please refer to general notes and air balance schedule on plan sheet M1.1.) The fan operation of "Type II" exhaust hood fan shall be interlocked with the existing HVAC units, as indicated in the general notes section of the revised drawing M1.1. Building Comments: June 12, 2009 by Joanna Spencer, Development Engineer (206) 431 -2440 1. The door opening into the bathroom in front of the sink does not meet accessibility for 60 inch minimum maneuvering clearances at doors. Also doors shall not swing into the clear floor space of any fixture. Please revise the floor plan for the bathroom where the door and • • Bill Rambo, Permit Technician July 8, 2009 City of Tukwila Community Development -3- fixtures shall be placed to meet accessibility clear floor space and maneuvering requirements. (ANSI 404.2.3 & 1004.11.1.1) Response: Interior door to restroom has been reduced to 34" wide, lavatory has been rotated and new exterior wall was pushed out a few inches to accommodate the required space, see sheet A 1 . 1 . 2. Sheet Al. IA details 02 & 03 indicated R -30 ceiling insulation and the detail (03) shows R -19 for a wall infill. Revise plan to show R -38 attic insulation and all new exterior walls R -21. (2006 WSEC Table 13 -1 & footnote #3) Response: R38 ceiling insulation has been noted and R21 is noted for the exterior walls on sheet A 1.1 A. Public Works Comments: June 19, 2009 by Joanna Spencer, Development Engineer (206) 431- 2440 A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA) shall be installed immediately downstream of the existing permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Rock/Box or equal freeze protection enclosure anchored to a minimum 4" concrete pad. Public Works strongly recommends a power supply for the freeze protection enclosure. On your site plan please show the property line(s), street name, North arrow, building location and size of existing permanent water meter and proposed RPPA. Show manufacturer name and backflow model number. Submit RPPA cut sheet and a construction cost estimate for backflow installation. Response: A RPPA has been added to the project reference sheet AU1.1 for more information. We believe that the above responses, together with the enclosed revised plans and technical documents, address all of the comments in The City of Tukwila C \correction letters listed above. Please review and approve the enclosed at your earliest convenience. If you have questions or need additional information, please do not hesitate to contact me at this office at 425- 656 -7430 or ainigues(&,,barghausen.com. Thank you. Sincerely, MAI /LKH /pj [ 1975c.061.doc] enc: As Noted cc: Brian Wall, Global Alliance Bovis Lend Lease Jay S. Grubb, Barghausen Consulting Engineers, Inc. Daniel B. Goalwin, Barghausen Consulting Engineers, Inc. Caryl Mattson, Barghausen Consulting Engineers, Inc. */ ✓M. Alexia lnigues Project Planner June 22, 2009 Alexia Inigues Barghausen Consulting Engineers 18215 72 Ave S Kent, WA 98032 Department of Community Development Jack Pace, Director RE: CORRECTION LETTER #1 Development Permit Application Number D09 -096 ARCO AM/PM — 5800 Southcenter Bl Dear Ms. Inigues, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Public Works Departments. At this time the Fire and Planning Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached memo. Jim Haggerton, Mayor Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. I have also enclosed a Non - Residential Sewer Use Certification that must be completed prior to issuance of the permit. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, fer Marshall it Technician encl File No. D09 -095 W:\Pemut Center \Correction Letters \2009\D09 -096 Correction Letter #1.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 (P:Joanna/Comments 1 D09 -096 PW) • 1 PUBLIC WORKS DEPARTMENT COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards DATE: June 15, 2007 PROJECT: ARCO AM /PM Tenant Improvement 5800 Southcenter Blvd. REVIEW #: 1 PERMIT NO: D09 -096 PLAN REVIEWER: Contact Joanna Spencer at (206) 431 -2440 if you have any questions regarding the following comments. In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross - connection control program to protect the public water system from contamination via cross - connection. Since the project includes alterations to the existing plumbing system, the entire plumbing system must be brought up to the current standards as set forth in the Uniform Plumbing Code including installation of an approved backflow prevention on the fire line and the domestic water supply to the building. The City has determined that the subject building has deficiencies on domestic water service line. A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPPA) shall be installed immediately downstream of the existing permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Rock/Box or equal freeze protection enclosure anchored to a minimum 4" concrete pad. Public Works strongly recommends a power supply for the freeze protection enclosure.On your site plan please show the property line(s), street name, North arrow, building location and size of existing permanent water meter and proposed RPPA. Show manufacturer name and backflow model number. Submit RPPA cut sheet and a construction cost estimate for backflow installation. I have enclosed Development Bulletins C5 and A9, which spells out design and installation requirements for cross connection control. A separate letter was mailed to BP West Coast Products LLC, the property owner. The Public Works Director will withhold issuance of this Tenant Improvement permit until the Permit Center receives plans for RPPA installation (under a revision to this TI permit or under a separate PW permit application) or a bond in the amount equal to 150% of the design, installation, and RPPA testing cost together with a letter stating the installation by a certain date. January 31, 2009 Voice (714) 670 -3928 Fax (714) 670 -5420 Email deraax@bp.com Re: EVR Phase II Installation To Whom It May Concern: • r BP West Coast Products 4 Centerpointe Drive, LPR4 -451 La Palma, California 90623 -1066 Mailing Address: Box 6038 Artesia, CA 90702 -6038 Please accept this letter as BP /Arco's approval for Barghausen Consulting Engineers, Inc. to sign and obtain permits on behalf of BP /Arco for the above mentioned program. If you have any questions, please contact me at (714) 670 =3928. Sincerely, Aline DerAlexanian Environmental Compliance Specialist U.S. Convenience Operations cm�o�n�Sww JUN 092009 PERMIT CENTER V0 016 DEPARTMENTS: g i Bull n � vislon Public Wo rks 0'--19 i i � PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D09 - 096 DATE: 07 - - PROJECT NAME: ARCO AM /PM SITE ADDRESS: 5800 SOUTHCENTER BL. Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ ❑ Permit Coordinator ❑ DUE DATE: 07 -09 -09 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route C4 Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: Planning Division Not Applicable Not Approved (attach comments) ❑ DATE: DUE DATE: 08-06-09 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D09 -096 PROJECT NAME: ARCO AM /PM SITE ADDRESS: 5800 SOUTHCENTER BL DATE: 06 -09 -09 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTME S: trial. uTding pp ivisiol '� i )Ilc Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Approved n Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 10ERMiT COORD COPY el PLAN REVIEW /ROUTING SLIP Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Approved with Conditions W( 1 Bldg A ` (1-a -oy 41 ip v Prevention Planning Division Structural Incomplete Permit Coordinator DUE DATE: 06-11-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: n DATE: DUE DATE: 07-09-09 Not Approved (attach comments) DATE: Fire ❑ Ping ❑ PW Staff Initials: Project Name: ARco AM /PM Contact Person: M. Alexia Inigues Summary of Revision: SheetNumber(s): Sheet No. Al -1A. Entered in Permits Plus on • a City of Tukwila \applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: 1 -2009 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwilu.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I 1 a0O Plan Check /Permit Number: D09 -096 ❑ Response to Incomplete Letter # Q Response to Correction Letter # 1 "T Mut ❑ Revision # after Permit is Issued JUL 0 8 2009 ❑ Revision requested by a City Building Inspector or Plans Examiner L J PERMIT CENTER Project Address: 5800 Southcenter Boulevard Please see response to comments letter attached dated July 8, 2009. BCE #1975.75 425 - 656 - '5C0 ; Phone Number: airrizilecaharghansen . rnm "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 1975.035.pdf Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory LOAliii 2 1 ) Sink, Clinic flushing 8 8 Sink, kitchen / 3 2 f Sink, other (servici6A6 4 aelacg) 3 1.5 3 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 1 Water closet, tank or valve, >1.6 GPF 8 4 kg King County Department of Natural Resources and Parks Wastewater Treatment Division Non- Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type 5sw Sc cen -iced &\/D, Property Street Address kAAJ I a-) W A ¶ City State ZIP Owner's Name V V CS r CI'�Qc r-t i C T, Subdivision Name Lot # Subdiv. # Block # Building Name A m I P i'Yl OAS 577471 bk/ (if applicable) (7-P-1 ) ( - c) - 5'/D Owner's Phone Number (with Area Code) Property Contact Phone Number (with Area Code) Owner's Mailing Address y ee.v)kr Oin cviv, LPZ4_tS1 9A r 1 A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units MOP Oki 'JEW - qy- Fxture Units CO Residential Customer Equivalent (RC Ori4 REV/N.01 20 fixture units equal 1.0 RCE Total No. of Fixture Units 20 J Signature of Owner /Representative Print Name of Owner /Representative 1058 (Rev. 9/07) I 6)/44 sef! I Engi rS -Lc R RCE For King County Use Only Account # No. of RCEs Monthly Rate Property Tax ID # I I5' 7 0 — D Party to be Billed (if different from owner) City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre - existing building on this property. Credit for a demolition may be given under some circumstances. Demolition of pre- existing building? �❑ es E i 1 r Was building on Sanitary Sewer? L`SYes ❑ No Was Sewer connected before 2/1/90? Ca es ❑ No Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? ❑ Yes ❑ No B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) = 187 C. Total Residential Customer Equivale (add A & B) CITY O TUKWILA A JUN 0 9 2009 PERMIT CENTER • 3 RCE RCE POWV Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of co rected dat for determination of a revised capacity charge. EMT Date (e /3 />�0nq I'. .&r6,r- t zserl �_/�� i 69S1‘).--44-1 .r/reic i: White — Kim] County Yellow — Local Sewer Aaencv Pink — Sewer Customai " 'PSI] ca;t) Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 TRAVELERS CAS It SURETY CO 103408839 03/05/2002 Until Cancelled 4/1/2001 ARCHIVED $12,000.00 02/14/2002 1 TRAVELERS CAS It SURETY CO 103408839 03/05/2001 03/05/2002 $6,000.00 03/05/2001 License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status JWPARCL033JA J W PARK CONSTRUCTION LLC CONSTRUCTION CONTRACTOR GENERAL UNUSED 4/1/1997 4/1/2001 ARCHIVED Untitled Page General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company JOE PARK CONSTRUCTION LLC 5094525122 PO BOX 527 YAKIMA WA 989070527 YAKIMA Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602100482 ACTIVE JOEPACL994DE CONSTRUCTION CONTRACTOR 3/5/2001 3/5/2011 GENERAL UNUSED Other Associated Licenses Business Owner Information Name PARK, JOE Role Effective Date 01/01/1980 Expiration Date Bond Information I Insurance Information I I • I I 1 I a I I Page 1 of 2 I https: // fortress .wa.gov /lni/bbip/Detail.aspx 07/20/2009 CUENT: bp AYe 6� k� A,,,, IF ARCO BP WEST COAST PRODUCTS, LLC il p H A (j . A. ° c. iv G ENG‘ 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION A 05.26.09 PERMIT REVIEW — BP /' \ 06.05.09 ISSUED FOR PERMIT — CITY 06.23.09 SIGN PERMIT REVIEW — CITY / 4 \ 06.23.09 RESPONSE TO COMMENTS A A A A A A SEAL: J\ O N a 9 ' °NA L TO E\‘ \\ �� 0 A ' S F 0 W A ' Ifv. * : • ‘:24 39913 O CONFIDENTIALITY STATEMENT: THAT OF AGREES TO AND TO ANY OTHER COPIES OF THE THE WHICH AVAILABLE, TO OF THE GLOBAL THE RECIPIENT OF THESE MATERIALS UNDERSTANDS COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT RETAIN THESE MATERIALS IN STRICT CONFIDENCE AGREES NOT TO DISCLOSE THESE MATERIALS PARTY AND FURTHER AGREES NOT TO MAKE MATERIALS. THE RECIPIENT AGREES TO USE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR GLOBAL ALLIANCE HAS MADE THE MATERIALS AND RECIPIENT AGREES TO RETURN ALL MATERIALS GLOBAL ALLIANCE EITHER UPON COMPLETION INTENDED PURPOSE OR UPON THE REQUEST OF ALUANCE, WHICHEVER COMES FIRST, DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I -5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: ALLIANCE Z &DM: CHECKED BY: BP REPM: DRAWN BY: AWANCE PM: VERSION: PROJECT N0: 1975.75 DRAWING TITLE: SITE N SHEET NO: AS1.1 EXISTING PARKING EXISTING DRIVEWAY NEW EXHAUST EXISTING PARKING EXISTING OFFICE EXISTING SALES ROOM EXISTING PARKING EXISTING SALES ROOM REMODEL INTERIOR OF EXISTING CONVENIENCE STORE REPAINT EXTERIOR REPLACE SIGN 28SF ADDITION TO ACCOMMODATE NEW UNISEX ACCESSIBLE RESTROOM XISTING COOLER ►® ,� ®� ±58' - 0" TO NEW ADDITION NEW A � NIS RESTROOM EXPAND SALES AREA INTO EXISTING COVERED PORCH AREA INSTALL RPPA, SEE SHEET AU1.1 — EXISTING PIC UNIT, COLUMN MTD. EXISTING PIC UNIT, COLUMN MTD. EXISTING PLANTER A= 1'36'16" - EXISTING CANOPY TO REMAIN. PROVIDE NEW GRAPHICS EXISTING ADA RAM P 0 REPLACE EXISTING SIGN W/ NEW 0 R= 565•.65' L= 158.49' RESTRIPE /PAINT EXISTING ACCESSIBLE PARKING STALL (AND PATH) REFER TO AS1.2 EXISTING UNDERGROUND STORAGE TANKS EXISTING DRIVEWAY N 0, M 0 N M N z - S64'26'45 "E 104.85' � i\\\\\ O\\\ O\\\\ O\\\\\\ O\\\\\\\ OO\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Op\\\\\\\\ p\\\\\\\\\\\\\\\ O\\ p�\\\\\ ���\\\\\ lma\\num\\\\\\ xtum\\\\ q\O\\\\\ \O \h\\O\\ \ \ \ \ \ \ \ \ \ \ \ \ \\ GENERAL PROJEC T NOTES EXISTING WATER METER SOUTHCENTER BOULEVARD A. ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE BUILDING CODES AND LOCAL RESTRICTIONS. CONTRACTORS MUST COMPLY WITH CONTRACTOR REGISTRATION REQUIREMENTS OF ALL GOVERNING AUTHORITIES. THE GENERAL BUILDING PERMITS SHALL BE PAID FOR BY THE OWNER. ALL OTHER PERMITS SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR DIRECTLY RESPONSIBLE. ALL REQUIRED CITY, COUNTY AND /OR STATE LICENSES SHALL BE ACQUIRED AND PAID FOR BY THE INDIVIDUAL SUBCONTRACTOR. B. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT SAME INFORMATION. CONTRACTOR SHALL MAINTAIN ONE COMPLETE SET OF PLANS ON THE PREMISES IN GOOD CONDITION AT ALL TIMES. THIS SHALL INCLUDE ALL ADDENDA AND CHANGE ORDERS. C. DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS, DRAWINGS AND SPECIFICATIONS ARE NOT INTENDED. THE CONTRACTOR IS TO CLARIFY ANY SUCH DISCREPANCIES WITH THE ARCHITECT /CONSULTANT PRIOR TO COMMENCING WORK. D. STATED DIMENSIONS TAKE PRECEDENCE OVER GRAPHICS, DO NOT SCALE DRAWINGS TO DETERMINE LOCATIONS. THE ARCHITECT /CONSULTANT SHALL BE NOTIFIED OF ANY SUCH DISCREPANCIES PRIOR TO CONTINUING WITH WORK. E. GENERAL CONTRACTOR TO REFER TO THESE DOCUMENTS AS WELL AS SPECIFICATIONS FOR IDENTIFICATION OF ALL OWNER SUPPLIED ITEMS, ALL ITEMS NOT MARKED AS 'OWNER SUPPLIED' ARE TO BE SUPPLIED BY GENERAL CONTRACTOR. UNLESS NOTED OTHERWISE, ALL ITEMS ARE TO BE INSTALLED BY GENERAL CONTRACTOR. F. FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S APPROVED SHOP DRAWINGS /DATA SHEETS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. PROVIDE (2) 6" GUARD POSTS. MATCH EXISTING 0 10 20 NIL \ \`� REPAINT DIRECTIONAL ARROWS. TYPICAL G. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE JOB IS IN PROGRESS AND UNTIL BUILDING IS OCCUPIED. H. ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN (BROOM) CONDITION AT ALL TIMES. I. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. J. CONTRACTOR SHALL PROVIDE TEMPORARY WATER, POWER AND TOILET FACILITIES AS REQUIRED. K. GENERAL CONTRACTOR IS RESPONSIBLE FOR RECEIVING, UNLOADING, UN- CRATING, INSTALLATION AND HOOKUP OF ALL FOOD SERVICE EQUIPMENT AND OTHER OWNER FURNISHED ITEMS. L. GENERAL CONTRACTOR IS REQUIRED TO LABEL ALL ELECTRICAL PANELS, PLUMBING VALVES, AND ROOF TOP EQUIPMENT. PLASTIC PHENOLIC ENGRAVED PLATE SCREWED ON. M. IT IS THE INTENT OF THE ARCHITECT THAT THIS WORK BE IN CONFORMANCE WITH ALL REQUIREMENTS OF THE BUILDING AUTHORITIES HAVING JURISDICTION OVER THIS TYPE OF CONSTRUCTION AND OCCUPANCY. N. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. 0. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. P. MATERIALS LISTED IN DRAWINGS ARE BASED ON DESIGN INTENT. ALTERNATE SPECIFICATIONS MAY BE ACCEPTED PROVIDED THEY CLOSELY MATCH SPECIFIED MATERIAL. CONTRACTOR IS TO SUBMIT PROPOSED SAMPLES OF SUBSTITUTIONS, ALONG WITH SAMPLE OF THAT SPECIFIED IN DRAWINGS FOR REVIEW BY THE OWNER. Q. GC TO REFER TO BID DOCUMENT PACKET FOR OWNER'S SCOPE OF WORK. SAID DOCUMENT TAKES PRECEDENCE OVER ANY SCOPE THAT MAY BE PRESENTED IN THIS SET OF CONSTRUCTION DOCUMENTS OR SPECIFICATIONS. 40 N65'50'45"W 5.01' VOC /nlT Y MAP SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing a Gas Piping City of Tukwila BUILDING DIVISION f ELE COPY Parlt No., , M Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approve old Copy t nd nditio is a owledged: BY Date:, C��-► City C7111 Ala C UILDIi G D IO REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2009 City of kwiIa BUILDING IVISIQN P.. NING APPROVED • No change° ho merio. to U1300 pant) without opproval from the PE Ina DivIoton COD SITE PLAN R. ALL WORK SHALL BE PERFORMED AS SHOWN ON THESE PLANS AND IN ACCORDANCE WITH "ARCO" STANDARD SPECIFICATIONS. S. WHERE LOCAL CODES, ORDINANCES OR REGULATIONS ARE MORE RESTRICTIVE THAN "ARCO'S" STANDARD SPECIFICATIONS, THEIR LOCAL REQUIREMENTS SHALL GOVERN. T. ANY DISCREPANCY BETWEEN FIELD CONDITIONS AND THESE PLANS ARE TO BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER. NO WORK SHALL BE PERFORMED ON THE ITEMS IN QUESTION UNTIL DIRECTED BY THE OWNER. NOTE: BARGHAUSEN HAS NOT PERFORMED AN ADA SURVEY TO VERIFY THE EXISTING SITE AND STORE ACCESSIBILITY. CONTRACTOR TO CONFIRM LOCAL ACCESSIBILITY WITH INSPECTOR AS REQUIRED. CONTACT GLOBAL ALLIANCE PM OR FRANCHISE CONSULTANT TO GET COPY OF LAST SURVEY AND TO CONFIRM ALL NECESSARY UPGRADES FOR CONSENT DECREE HAVE BEEN PERFORMED. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SCALE: 1 "= 20' siONEMMIIMMEW SITE DATA ADDRESS: 5800 SOUTHCENTER BLVD. TUKWILA, WASHINGTON OWNER: BP WEST COAST PRODUCTS, LLC 4 CENTERPOINTE LA PALMA, CA LOT SIZE: 18,593 SQUARE FEET APN: 1157200352 ZONING: RCM (REGIONAL COMMERCIAL MIXED —USE) BUILDING AREA: 1,811.4 SQUARE FEET (EXISTING) 26 SQUARE FEET ADDITION TO STORE 1,500 SF (CANOPY) CONSTRUCTION TYPE: I1 -B NON - SPRINKLERED (STORE); II -B (CANOPY) OCCUPANCY: M (STORE AND GAS) HEIGHT: EXISTING ±18' SCOPE OF WORK TENANT IMPROVEMENT TO EXISTING STORE INTERIOR CONSISTING, BUT NOT LIMITED TO: DEMOLITION AND REPLACEMENT OF NON LOAD BEARING WALLS NEW FLOOR FINISHES LIGHTING IMPROVEMENTS NEW CABINETS & COUNTERTOPS NEW FOOD SERVICE EQUIPMENT NEW GONDOLAS NEW WALL FINISHES AND PAINTING UPDATE EXTERIOR SIGNS UPDATE EXTERIOR PAINT COLORS APPLICABLE CODES 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL FIRE CODE 2006 UNIFORM PLUMBING CODE 2006 NATIONAL ELECTRICAL CODE 2006 INTERNATIONAL MECHANICAL CODE DRAWING INDEX SITE PLANS AS1.1 SITE PLAN 1.2 SITE P DETAILS ARCHITECTURAL A.0.1 DEMOLITION PLAN A.1.1 CONSTRUCTION FLOOR PLAN A.1.1A M CELLANEO S ' ALL DETAILS A.1.2 FLOOR FINISH PLAN A.1.3 REFLECTED CEILING PLAN A.2.0 EXTERIOR ELEVATIONS C -STORE & CANOPY REIMAGE A.2.3 INTERIOR ELEVATIONS A.2.4 INTERIOR ELEVATIONS A.2.5 INTERIOR ELEVATIONS EQUIPMENT Q1.1 EQUIPMENT PLAN Q2.1 EQUIPMENT SCHEDULE E1.1 ELECTRICAL ROUGH -IN PLAN E1.2 ELECTRICAL FLOOR PLAN E1.3 ELECTRICAL DEMO /LIGHTING PLAN E1.4 ELECTIRCAL SCHEDULES & DIAGRAMS U B P.1.1 PLUMBING DEMOLITION /ROUGH -IN PLANS, NOTES, LEGENDS & DETAILS M.1.1 MECHANICAL PLAN, SCHEDULES, NOTES & DETAILS P RECEIVED CITY OF TUKIMLA JUL 0 2009 PERMIT CENTER CORRECTION LTR# I CONSULTANTS ARCHITECT /ENGINEER: CONTACTS: PLUMBING /MECHANICAL /ELECTRICAL: CONTACT: BARGHAUSEN CONSULTING ENGINEERS INC. 18205 72ND AVENUE S. KENT, WA 98032 DANIEL B. GOALWIN (425) 656 -7441 CARYL J. MATTSON (425) 656 -1063 SACRAMENTO ENGINEERING CONSULTANTS 10555 OLD PLACERVILLE ROAD SACRAMENTO, CA 95827 CHRIS GILLAND, (916) 368 -4468 COIVF /DENT /AL /T Y S TA TEMEIV T,• THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. MAXIMUM SLOPE IN ANY DIRECTION SHALL NOT EXCEED 2% 36 "x36" BLUE STENCILED SIGN (DETAIL 8B) NOT TO SCALE NOT TO SCALE EQUAL 9' -0" SEE SITE PLAN ADA PAR PAVEMENT INTERNATIONAL SYMBOL OF ACCESSIBILITY NOTES: A. SYMBOL TO BE CENTERED ON WIDTH OF PARKING STALL. B. BOTTOM OF SYMBOL TO BE LOCATED FLUSH WITH ACCESS DRIVE,CENTERED ON PARKING SPACE. C. SYMBOL IS REQUIRED TO CONTRAST WITH BACKGROUND. ERNATIONAL SYMBOL OF ACC PARKING AREA EQUAL 8' -0" (VAN) 5' -0" (CAR) WHITE PAINT FIGURE PAINT CONTRASTING BLUE BACKGROUND WHITE BORDER ACCESS AREA -4" WIDE PAINTED STRIPES (TYP.) SSIBILITY REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2009 RESERVED PARKING SCALE: NONE Accessibility Notes (WHITE) (BLUE) SYMBOL & OUTLINE BACKGROUND 12'x 18" SIGN TEXT ACCORDING TO LOCAL JURISDICTIONAL REQUIREMENTS WHEN SPECIFIED 36 "x36" BLUE STENCILED SIGN -- HEIGHTS ACCORDING TO LOCAL REQUIREMENTS IF SIGN IS LOCATED IN PEDESTRRIAN TRAFFIC, LOCATE BOTTOM OF SIGN AT +6' -8" ABOVE WALKING SURFACE ` FLEXIBLE POST ON SHORT POLE INSTALLATIONS ZUMAR INDUSTRIES (800) 426 -7927 OR 2"0 STEEL POLE ON INSTALLATIONS ABOVE 5' -0" Parking Sign Parking Stall Stencil Marking Detail (Handicapped Parking) Store Entrance ENTRANCE DOOR WITH MINIMUM 10" HIGH BOTTOM RAIL OR AS REQUIRED BY LOCAL AUTHORITY. G.C. TO CONFIRM. 2. ADJACENT WALK : 60 "x60" MINIMUM LEVEL AREA OUTSIDE DOOR EXTENDING 24" MINIMUM BEYOND DOOR STRIKE EDGE (SEE SITE PLAN FOR EXACT CONFIGURATION). 3. SEE ARCHITECTURAL BUILDING PLANS FOR ADDITIONAL INFORMATION. Parking Notes (SEE SITE PLAN FOR EXACT LOCATION & CONFIGURATION) 1. SIZE SEE SITE PLAN AND DETAIL 1 ON THIS PAGE 2. LOCATION : LOCATE PARKING SO THAT PHYSICALLY IMPAIRED PERSON IS NOT REQUIRED TO WALK OR WHEEL BEHIND OTHER PARKED CARS TO GET TO STORE ENTRANCE. 3. SIGNAGE A. PHYSICALLY IMPAIRED PARKING SPACE SHALL BE IDENTIFIED BY A PERMANENTLY AFFIXED REFLECTORIZED SIGN CONSTRUCTED OF PORCELAIN ON STEEL, BEADED TEXT, OR EQUAL, DISPLAYING THE INT'L SYMBOL OF ACCESSIBILITY. SEE DETAIL 3A'. WHEN SITE PLAN CALLS FOR VAN SPACE, INCLUDE THE 60 SQ. INCH "VAN ACCESSIBLE" SIGN BELOW THE PARKING SIGN. B. 36 "x36" BLUE STENCIL ON PARKING SURFACE SEE DETAIL 2, 3B AND SITE PLAN. RECEIVED CITY OF TUKWILA JUL 0,8 MOH PERMIT CENTER CUENT: BP WEST COAST PRODUCTS, LLC 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES 05.26.09 06.05.09 06.23.09 REVISION DESCRIPTION PERMIT REVIEW - BP ISSUED FOR PERMIT - CITY SIGN PERMIT REVIEW - CITY SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ 1.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: ALLIANCE Z &DM: BP REPM: ALIJANCE PM: PROJECT NO: 1975/5 DRAWING TITLE: SITE PLAN DETAILS SHEET NO: EXISTING DRIVEWAY REMODEL INTERIOR OF EXISTING CONVENIENCE STORE NO PAR[ ON EXISTING DRIVEWAY BOOTHS 10 LEGEND: EXISTING MONITORING WELL EXISTING STORM CATCH BASIN EXISTING WATER METER PROPOSED RPPA PROPERTY LINE 20 N 0) N z EXISTING TELEPHONE (UNDERGROUND) EXISTING CURB - T(UG) F] El W r O r PROPOSED WILKINS MODEL 375 1" REDUCED PRESSURE PRINCIPLE ASSEMBLY AND ENCLOSURE PER DETAIL THIS SHEET n - ........ EXISTING WATER SERVICE EXISTING CANOPY OVER 4 MPD'S EXISTING PLANTER EH P S64'26'45 "E 104.85' J A=1'36'16" EXISTING 1" METER EXISTING 1" WATER SERVICE L, ) 0 0 0. 0 0 PROPOSED UNDERGROUND 1/2" ELECTRICAL CONDUIT FROM EXISTING I.D. SIGN /PHONE BOOTH TO HOTBOX ENCLOSURE R= 5659/6 EXISTING UNDERGROUND STORAGE TANKS L= 158.49' SOUTHCENTER BOULEVARD 3 0 0 0 EXISTING / I.D. SIGN EXISTING TELEPHONE ‘A1 N65'50'45"W 5.01' w CONNECT TO METER ASSEMBLY WITH THREADED COUPLING NOTES APPROVED COMPACT BACKFLOW PREVENTION DEVICE INCLUDING ABOVE GRADE PIPING NOT TO BE PAINTED. IN ORDER TO ALLOW FOR ACCESS AND MAINTENANCE OF BACKFLOW ASSEMBLIES A MINIMUM OF THREE (3) FEET ADJACENT TO BACKFLOW ASSEMBLY PAD SHALL BE LEVEL AND FREE OF SHRUBBERY AND OBSTRUCTIONS (TYP). LEGEND (1 WILKINS MODEL 375 1" REDUCED PRESSURE PRINCIPLE `' ASSEMBLY(RPPA) Q: BRASS ''90- BEND - IRON PIPE THREAD (IPF x IPF) 03 BRASS PIPE STANDARD TBE 04 BRASS CLOSE NIPPLE (IPF = IRON PIPE FEMALE, 2" MIN. CONCRETE AROUND, ENCLOSURE (TYP) SECTION A -A 3" MIN 3" MIN SECTION B-B MIN' WRAP BRASS PIPE WITH 10 MIL DIELECTRIC TAPE WITH 1/2 OVERLAP TO PREVENT BONDING IPM - = IRON PIPE MALE, TBE = THREADED BOTH ENDS) "MIN 4" MIN 12" MIN * INSIDE ENCLOSURE DIMENSIONS , .a:e7446:+:i- +aawa:u:cw.a:►_•W W4Pi v:w.10W4/11 :c111:.:vcati.6:us w.4 k i kl j ■ II REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 7 2009 City of Tukwila BUILDING DIVISION 0 BRASS UNION - IRON PIPE THREAD (IPF x IPF) (IF NOT PROVIDED WITH ASSEMBLY) 0 CONCRETE PAD - 3000 PSI (PAD SIZE TO MEET ENCLOSURE MANUFACTURERS SPECIFICATIONS) 0 HOTBOX ENCLOSURE WITH HEAT TAPE POWER SUPPLIED FROM TELEPHONE BOOTH /I.D. SIGN SO ANCHOR: PER MANUFACTURERS REQUIREMENTS NOT TO SCALE FILE NAME: UDACS -11A DRAWN BY: SDM CHECKED BY: SPM BACKFLOW PREVENTION ASSEMBLY 1" — 2" DIAMZER UDACS PLATE NO. 11A SHEET 1 OF 1 UN\IPORV DESIGN STANDARDS FOR WATER DISTRIBUTION SYST -MS NOTES: 1. CONTRACTOR SHALL RE -ROUTE ALL POWER AND PHONE LINES TO EXISTING STRUCTURES TO REMAIN (LIGHTS, PHONES, SIGNS, AIR /WATER UNIT, ETC.), AS REQUIRED TO PROVIDE SERVICE AT COMPLETION OF PROJECT. 2. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF EXISTING UTILITY LINES TO REMAIN IN SERVICE. IF EXISTING UTILITY LINE IS NOT OF SUFFICIENT DEPTH TO MAINTAIN MINIMUM SLOPES NEW CONNECTION, CONTRACTOR SHALL NOTIFY ENGINEER FOR DESIGN REVISION. 3. THE EXISTING UTILITY LOCATION /CROSSING /CONNECTION AS SHOWN IS APPROXIMATE, BASED ON FIELD SURVEYS AND "AS- BUILT" RECORDS. THE GENERAL CONTRACTOR SHALL "POTHOLE" THE EXISTING UTILITY TO FIELD VERIFY THE MATERIAL, DIAMETER AND LOCATIONS (INCL. ELEVATIONS) PRIOR TO CONSTRUCTION. ANY DISCREPANCIES IN THE LOCATION OF THE EXISTING UTILITY OR INCOMPATIBILITY OF THE DESIGN SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNERS REPRESENTATIVE, THE CITY, AND BARGHAUSEN CONSULTING ENGINEERS (425- 251 - 6222). RECEIVED CITY OF TUKWILA JUL 0.8.2009 PERMIT CENTER CLIENT: ARCO BP WEST COAST PRODUCTS, LLC # C) dl < izv Q' G E N G ‘°. 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX • CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. A A A A A A A DATE 05.26.09 06.05.09 06.23.09 0623,09 REVISION DESCRIPTION PERMIT REVIEW - BP ISSUED FOR PERMIT - CITY SIGN PERMIT REVIEW - CITY RESPONSE TO COMMENTS SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALUANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ 1 -5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: ALLIANCE Z &DM: BP REPM: ALLIANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: UTILITY PLAN 07.06.2009 SHEET NO: AU1.1 SCALE: k = 1' -O" ROOF RIDGE C�7 - STORE w oa_ O Li U 0 0 cc • EXISTING ROOF PLAN: A1.1A EXISTIN OFFICE G11 f � . MOP SINK noP I O LOW WALL - '44 111011) Al OA REMOVE WALL FROM FLOOR TO 7' ABV. FLOOR — EXISTING 2" ELECT. SERVICE CONDUIT TO BE UNDISTURBED 3 / Dome, PREP FLOORING Ti ACCOMMODATE ELI CTRICAL CONDUIT LOCATIO V.I.F. II a GO I II REMOVE 9' -8 TO ACCOMMODATE NEW NEW HAND SINK PREPARE ROOF FOR EXHAUST FAN / \ AREA OF'\- SHEETIMETAL\/ CEILING TO BE REMOVED D I ITION EXISTING SOFFIT TO REMAIN EXISTING GRAPHIC PANEL TO BE RE— IMAGED OR REPLACED BY OTHERS, TYPICAL EXISTING 3" STEEL COLUMN TO REMAIN, START POINT FOR NEW REST ROOM ADDITION CASHIER ON OF SHEET CEILING TO REMAIN EXISTING SALES AREA__._ 0 EXISTING .._ PREFAB COOLER (NO CHANGES) EXTERIOR CAMERAS TO REMAIN, TYP. EX. HEADER © 8' -4" ABV. FIN. FLR. TO REMAIN MODIFY EXISTING OVERHEAD SHELVING UNIT REVERSE DOOR SWING REMOVE EXISTING DOORS & FRAMES, DISPOSE OR SALVAGE AT OWNER's REQUEST (TYP.) EXTERIOR LIGHTING TO REMAIN, TYP. RETAIN THIS PORTION OF WALL TO ACCOMMODATE NEW EXTERIOR WALL, SEE A1.1 EXISTING WALL TO BE REMOVED FROM FLOOR TO 7' ABV. FIN. FLR. TO MATCH EXISTING ADJACENT SOFFIT HEIGHT SALVAGE "Thirst Oasis" INTERNALLY ILLUMINATED SIGN FOR REUSE REMOVE EAVE LIGHTING FROM THIS AREA EXISTING BRICK & TOP CAP WILL BE REMOVED FROM FRONT WALL I I EXTERIOR LIGHTING TO REMAIN, TYP. AIM I Mil lir ' 10, AIRBOT lIJJ1J III I I FlifliTi IIIIIIII I I E I DEMOLITION FLOOR PLAN SCALE: 1/4" = l' -O" � — NEW ROOF OVER ADDITION TO BE 4 " /FT. SLOPE owl PROPOSED THRU —ROOF EXHAUST, SEE MECHANICAL DRAWINGS FOR MORE INFORMATION EXISTING CUPOLA EXISTING SATELLITE DISH EXISTING CONDENSERS CANOPY OUTLINE & EXISTING LIGHT FIXTURES (TO REMAIN) CEILING DEMO PLAN: SCALE: t = 1' -0" EXISTING STORAGE CONTAINER (NO CHANGES) 02 A1.1A AREA OF CONCRETE /ASPHALT TO BE REMOVED TO ACCOMMODATE ADDITION x PREPARE EXTERI6R WALL TO ACCOMMODATE NEW EXHAUST FAN, SEE MECHANICAL PLAN EXISTING COLUMN EXTERIOR LIGHTING TO REMAIN, TYP. EXISTING VENT RISERS EXISTING ELEC. GUTTER EXTERIOR LIGHTING TO REMAIN, TYP. LOCATION OF EXISTING OVERFILL ALARM, TO REMAIN EXTERIOR CAMERAS TO REMAIN, TYP. HATCH INDICATES EXISTING WALLS TO BE REMOVED, REFER TO KEYED NOTE 1 AND PLAN NOTES FOR SPECIAL HEIGHTS. REFER TO REFLECTED CEILING PLAN, A1,3 FOR THE FOLLOWING: (M) = MOVE (R) = RELOCATED (D) = DEMO FURTHER INFORMATION CAN BE FOUND IN THE ELECTRICAL DRAWINGS. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2009 City of Tukwila BUILDING DIVISION GENERAL NOTES: 1. THERMOSTATS NOT TO BE RELOCATED IF SITE IS USING ENERGY MANAGEMENT SYSTEM. CONTACT GLOBAL ALLIANCE PM OR OWNER FOR DIRECTIONS. 2. ALL ELECTRICAL CABLING AT SALES COUNTER SHALL BE IDENTIFIED, SAVED, AND PULLED TO BACK ELECTRICAL PANELS AS REQUIRED. SATELLITE CABLE SHALL NOT BE CUT IF LENGTH ALLOWS EXTENSION TO EXISTING CASHIER AREA. ITEMS WITH CALL —OUTS ARE EXISTING TO REMAIN OR RELOCATE, REFER TO Q1.1 AND Q2.1. 1 A1A 3. GENERAL CONTRACTOR IS RESPONSIBLE FOR RECYCLING ALL DEBRIS AND MATERIALS CREATED AS A RESULT OF THIS WORK PER CONSTRUCTION AND DEMOLITION, RECYCLING AND REUSE DOCUMENT. RECEIVED CITY OF TUKWILA JUL 0; 8 2009 PERMIT CENTER KEYED NOTES: REMOVE WALL SHOWN AS REQUIRED FOR NEW LAYOUT DEPICTED ON SHEET 0 A.1.1. CONTRACTOR TO VERIFY AND RELOCATE PLUMBING AND ELECTRICAL LOCATIONS PRIOR TO DEMOLITION OF ALL WALLS. RELOCATE THERMOSTATS AS NECESSARY. NOTE THAT SOME WALLS ARE REMOVED TO 7' ABV. FLOOR. LOCATION OF NEW CONDUIT STUB—UP. CONFIRM FINAL CONDIMENT COUNTER STUB —UP LOCATION WITH OWNER'S REPRESENTATIVE. SAW CUT SLAB AND INSTALL ELECTRICAL AS REQUIRED AND PATCH SLAB TO MATCH ADJOINING. ABANDON ALL EXISTING SALES FLOOR PLUG LOCATIONS FOR FLOORING OR AS DIRECTED BY GLOBAL ALLIANCE PM OR OWNER. SAW CUT AND PATCH SLAB FROM REMOVAL /RELOCATION OF EXISTING OR INSTALLATION OF NEW PLUMBING FIXTURES. SEE PLUMBING DRAWINGS FOR DETAILS. EXISTING ELECTRICAL CONDUIT LOCATIONS AT SALES COUNTER HAVE NOT BEEN VERIFIED. (CABINET TO REMAIN AND RECEIVE A NEW COUNTERTOP) REMOVE AND DISPOSE OF INTERNALLY ILLUMINATED "ampm" SIGN PER OWNER'S INSTRUCTIONS. PREPARE SOFFIT AREA FOR NEW "ampm" INTERNALLY ILLUMINATED SIGN. REMOVE SHEET METAL CEILING IN EXISTING REST ROOM TO ACCOMMODATE NEW ACOUSTIC PER A1.3. RETAIN EXISTING CEILING MOUNTS FOR NEW CIGARLIIE RACK, MODIFY WINDOW MOUNTING OF NEW RACK AS REQUIRED. REMOVE EXISTING VCT FLOORING FROM BACK ROOM AS INDICATED. PREPARE EXISTING CONCRETE FOR NEW VCT IN THIS AREA PER SHEET A1.2. REMOVE EXISTING VCT FLOORING FROM SALES AREA AND PREPARE EXISTING CONCRETE FOR NEW CERAMIC TILE PER SHEET A1.2. EQUIPMENT FOR EQUIPMENT TO REMAIN SEE SHEET Q1.1 AND Q2.1. ALL OTHER EQUIPMENT NOT USED IN NEW PLAN IS TO BE REMOVED AS DIRECTED BY THE OWNER AND THE NOTES BELOW. CONTRACTOR TO CONTACT ATM VENDOR FOR REMOVAL AND RELOCATION OF ATM MACHINE. CONTRACTOR TO COORDINATE SAFE REMOVAL WITH OWNER AND SAFE VENDOR. POS EQUIPMENT CONTRACTOR TO PACKAGE AND STORE ALL EXISTING POS EQUIPMENT AT EXISTING SALES COUNTER PRIOR TO DEMOLITION, COORDINATE WITH OWNER ON DISPOSITION. SECURITY SYSTEM CONTRACTOR TO CONTACT SECURITY VENDOR PRIOR TO DEMOLITION TO ARRANGE THE REMOVAL /STORAGE OF EXISTING SECURITY MONITORS AND CAM ERAS. FLOORING EXISTING FLOORING AND BASE IN SALES AREA & BACK ROOM WILL BE REMOVED, INCLUDING AREAS UNDER CABINETS (OFFICE FLOORING TO REMAIN, UNLESS OTHERWISE REQUESTED BY THE OWNER). PREPARE SLAB TO RECEIVE NEW FLOORING OR BASES AS REQUIRED; MATCH EXISTING. CABINETS VERIFY WITH GLOBAL ALLIANCE PM OR OWNER FOR EXISTING CABINETS AND COUNTERS TO BE REMOVED AND DISPOSED OF IN SALES AREA. CEILING REMOVE GRID, LIGHTING, AND CEILING TILES IN SALES AREA AS REQUIRED FOR NEW LAYOUT ON A.1.3. REPLACE STAINED OR DAMAGED ACOUSTIC TILES IN SALES AND BACKROOM AREAS AS REQUIRED BY HEALTH DEPARTMENT. REMOVE ALL SOFFIT CEILING FANS ABOVE FOOD SERVICE COUNTERS (IF APPLICABLE). GRAPHICS CONTRACTOR TO REMOVE EXISTING GRAPHICS AND SIGNS THROUGHOUT. CONTACT OWNER FOR DISPOSAL REQUIREMENTS. REPAIR /REPLACE FASCIA IN PREPARATION FOR NEW GRAPHICS. SHELVING CONTRACTOR TO DISASSEMBLE AND STORE ALL GONDOLA AND SALES SHELVING AS DIRECTED BY OWNER. CONTRACTOR TO DISASSEMBLE AND STORE ALL STORAGE CABINETS AND SHELVING IN BACKROOM AS DIRECTED BY OWNER. CONFIRM REUSE WITH OWNER. DEMOLITION NOTES: A. COORDINATE ALL DEMOLITION OPERATIONS WITH OWNER FOR SHUT DOWN PERIODS AND SEQUENCE OF WORK. PROTECT EXISTING HARDWARE AND DEVICES TO REMAIN. ASSURE CONTINUING FACILITY OPERATIONS. B. SCHEDULES OF ITEMS TO BE SALVAGED ARE TO BE PROVIDED BY THE OWNER, LOCAL AUTHORITIES, OR UTILITIES. ALL ITEMS TO BE TURNED OVER TO THE OWNER, LOCAL AUTHORITIES, OR UTILITIES SHALL BE PROTECTED DURING DEMOLITION AND REMOVAL AND SHALL BE DELIVERED TO THE APPROPRIATE PARTY IN AN UNDAMAGED CONDITION. C. REMOVE ALL DEMOLISHED MATERIALS NOT SCHEDULED FOR SALVAGE AND REUSE, OR THOSE TO BECOME PROPERTY OF THE OWNER, LOCAL AUTHORITIES, OR UTILITIES FROM THE SITE, AND DISPOSE OF IN ACCORDANCE WITH LOCAL REGULATIONS. D. ALL ITEMS SCHEDULED TO BE SALVAGED FOR REUSE SHALL BE REMOVED WITH CARE, STORED AND PROTECTED FROM DAMAGE UNTIL SALVAGED ITEMS ARE INCORPORATED IN THE NEW WORK. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPLACE AND /OR RESTORE ANY ITEMS SCHEDULED FOR SALVAGE AND REUSE THAT ARE DAMAGED DURING THE COURSE OF CONTRACT OPERATIONS. THE OWNER SHALL BE THE SOLE JUDGE OF SUITABILITY OF THESE SALVAGED ITEMS FOR REUSE IN THE WORK. E REUSE OF SALVAGED MATERIALS, NOT SPECIFICALLY SCHEDULED, WILL BE AT THE SOLE DISCRETION OF THE OWNER. IN NO CASE SHALL SALVAGED MATERIALS BE INCORPORATED IN THE WORK THAT DO NOT MEET MINIMUM REQUIREMENTS OF STATE AND LOCAL CODES AND REGULATIONS. F. IT IS NOT THE INTENT TO SHOW EVERY PIECE OR ITEM TO BE REMOVED IN DEMOLITION WORK. MECHANICAL, ELECTRICAL, AND OTHER WORK RELATED TO A WALL, OR- AREA SCHEDULED FOR DEMOLITION AND REMOVAL, SHALL BE PERFORMED WHETHER SO NOTED OR NOT. WHERE EXISTING WALL SUBSTRATES ARE TO BE REMOVED, ALL RELATED MECHANICAL, ELECTRICAL, ALARM, PHONE, P.O.S., SECURITY, CONTROLS, EXIT SIGNS, OUTLETS, ETC. SHALL BE PROTECTED AND WHERE REQUIRED, BE REMOVED AND REINSTALLED TO FIT FLUSH WITH NEW WALL FINISH. WHERE EXISTING MECHANICAL, ELECTRICAL OR PLUMBING ITEMS ARE RUN EXPOSED ON WALL SURFACE, CONTRACTOR SHALL OPEN WALL CAVITY AS REQUIRED TO CONCEAL THE ITEMS. G. DEMOLITION PLANS SHALL BE COORDINATED WITH DRAWINGS FOR NEW CONSTRUCTION (INTERIOR ELEVATIONS, DETAILS, ETC.) SO THAT THE EXACT BOUNDARIES OF SPECIFIC DEMOLITION MAY BE DETERMINED. H. PATCH /REPAIR /REFINISH ALL SURFACES EXPOSED BY DEMOLITION WORK TO MATCH AND ALIGN WITH EXISTING ADJACENT SURFACES SCHEDULED TO REMAIN, AND PREPARE TO RECEIVE NEW FINISHES SPECIFIED. WORK SHALL INCLUDE ALL LABOR AND MATERIALS ON ALL SURFACES REQUIRED TO RENDER SUBSTRATES ACCEPTABLE TO RECEIVE NEW FINISHES SPECIFIED IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS. . TERMINATE, CAP AND REMOVE ALL ABANDONED ELECTRICAL CONDUIT, WIRING BOXES, SWITCHES, ETC., PLUMBING AND PIPING FIXTURES, ETC. HVAC DUCTWORK, CONTROLS, PIPING, ETC. AS REQUIRED. J. THE CONTRACTOR SHALL V.I.F. ALL CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING WITH ANY WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING THAT FURNISHED BY SUBCONTRACTORS. K. WHEN WALLS, COLUMNS OR OTHER SUPPORTING AND /OR BRACING ELEMENTS ARE SCHEDULED FOR DEMOLITION, STRUCTURAL SUPPORTS AND BRACING FOR THE ADJACENT CONSTRUCTION SHALL BE PROVIDED AND MAINTAINED UNTIL THE PERMANENT SUPPORTING STRUCTURES ARE IN PLACE AND ABLE TO SUPPORT IMPOSED LOADS. L. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES AND TO PROTECT THEM FROM DAMAGE. CONTRACTOR SHALL BEAR . THE EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK. CLIENT: ARCO BP WEST COAST PRODUCTS, LLC TL NG ENG%— 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. A A A A tt t2 DATE 05.26.09 06.05.09 06.23.09 REVISION DESCRIPTION PERMIT REVIEW - BP ISSUED FOR PERMIT - CITY SIGN PERMIT REVIEW - CITY SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ 1 -5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: ALLIANCE Z &DM: BP REPM: ALLIANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: DEMOLITION FLOOR PLAN SHEET NO: A0.1 X z 0 Li LLI X II Q) 0 0 oo 0) oo 0 0 .1 0 L. 0) C_ 0 0 0 0 N 0 0 0 0 O 0 0 0 CLIENT: bp ,.,,,,, , - .,,,c ,,,,_ A,. , . ARCO BP WEST COAST PRODUCTS, LLC RP p H4 j ' • ^ . �� ^«n ����0K���� 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251-6222 (425)251-8782 FAX CIVIL BNG|NEER|NQ, LAND PLANN|N0, SURVEYINQ, ENVIRONMENTAL SERVICES wo DATE REVISION DESCRIPTION A 05.26.09 PERMIT REVIEW — op /\ STAINLESS STEEL TYPE 304 SUSP. GYPSUM PANELS /u� 06.05.09 ISSUED FOR PERMIT — CITY /1 PREFAB COOLER �u\ 06.23.09 SIGN PERMIT REVIEW — CITY /+\ 06.23.09 RESPONSE TO COMMENTS �� /»\ 0 /\ ±8' SALES AREA /o\ ±a' SALES AREA //\ A 0 /\ 0 0 /u\ /\ e /o\ 0 0 /\ �o\ ± 1 o' /\ /n�\ • A � SEAL: *o D A. . �k a o`^. '- °/0��[ " �� ' 0 CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALUANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FUR THER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT ���������� ~~��=~"�~~~�~°""" L&M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @|-5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: ALLIANCcZ&DM: oxummBY: BP REPM: DRAWN BY: AWANCE PM: VERSION: PROJECT NO: • 1975.75 DRAWING TIME: ������������UU����U���� ����N���U�������U��U»0 �������� �=��N� FLOOR PLAN SHEET NO: Al m 1 EXISTING 6" TS. COLUMNS SAW CUT PAVEMENT AND PROVIDE 6" THICK SLAB ON GRADE w/ #4 40 12" O.C. EA WAY @ CENTER OF SLAB OVER 8" OF COMPACTED, CLEAN. OPEN-GRADED COARSE ROCK. USE 10 MIL VAPOR BARRIER OVER COMPACTED ROCK. (MATCH EXISTING SALES ROOM ELEVATION) � A1.1A EXISTING OFFICE PT indr (NEW) FRP-1 NEW 8S (NEW) ENCROACH INTO REQUIRED 30" WIDE LAV SPACE. 34" DOOR --` FRP-1 '^^ (NEW) FINISH CUT SIDE OF WALL, SEE SECT. A1.1A �--NEW SOFFIT PORTION, FINISH CUT SIDE TO {}2 MATCH EXISTING ADJACENT SOFFIT / EXIS BACK � SEE SH FOR TYPICAL 8ACI1R{X}M EQUIP EXISTING STORAGE EXISTING WIRE GLAZING TO REMAIN - " J/ J ' / _� HAND SINK EXISTING pT | COFFEE/FOUNTAIN (EXIST) -'' - | -°r—�- CAL BACKROOM E 5'-6" OPENING A1.1A w ALIGN FACE MTL STUD WALL WITH SALES ROOM SIDE OF EXISTING 3" METAL SOFFIT ABV., SEE SECTION A1.1A A.2.4 EXISTING SALES AREA EXISTING | PT \/ CASHIER � )B0�� � (EXIST) EXISTING WIRE GLAZING TO REMAIN (EXIST) EXISTING COOLER -H EXISTING TRASH CONSTRUCTION FLOOR PLAN SCALE: 1/ � 1'—O" .,`" -�. .� -r w . . EXISTING STORAGE CONTAINER INTERIOR ELEVATION MARKER � /u`�/. `_��_vr` //.//� /v/,`/`u` DETAIL NUMBER SHEET NUMBER 01 03 6" ST. x , ' FINISH VARIES, REFER TO INTERIOR ELEVATIONS SUBSTRATE )i" GYB. 8D. WATER RESISTANT @ SINKS TYP. BOTH SIDES .'�• •` ` `• `,• METAL STUD @ 16" O.C. REVIEWED { JUL CODE COMPLIANCE "-FINISH VARIES, REFER TO INTERIOR ELEVATIONS GYP,' BD, BOTH SIDES AT DRY CONDITIONS PLAN DRYWALL: 1. INSTALL GYPSUM BOARD IN ACCORDANCE WITH RECOMMENDATIONS OF GYPSUM ASSOCIATION {Ar216. FLAME SPREAD CLASS: 2. SCREWS: SELF-DRILLING, SELF-TAPPING, TYPE "5". SIZES ARE RECOMMENDED BY GYPSUM BOARD MANUFACTURER FOR WALL AND CEILING APPLICATIONS. City of ���v�V VK8kwila F3NALDUNG DIVISION GENERAL NOTES A. CONTRACTOR SHALL INSTALL NEW PARTITIONS WITH DRY WALL AND FINISHES TO MATCH EXISTING OR AS NOTED. FINISHES MUST BE SMOOTH, LIGHT, AND WASHABLE, I.E., RESTISTANT TO MOISTURE. ALL NEW PARTITIONS SHALL BE BRACED FOR LATERAL FORCES, PER BUILDING CODE REQUIREMENTS. B. ALL DIMENSIONS SHALL BE FIELD VERIFIED BY CONTRACTOR FROM CABINET AND EQUIPMENT CLEARANCES PRIOR TO WALL ERECTION. DISCREPANCIES SHALL BE DIRECTED TO GLOBAL ALLIANCE PM OR OWNER. C. DIMENSIONS OF NEW WALLS ARE FROM FACE OF STUD. DIMENSIONS FROM EXISTING WALLS ARE FROM FINISHED FACE. D. ALL COUNTERTOPS SHAL BE MAX. 34" A.F.F. CONTRACTOR SHALL COORDINATE WORK WITH CABINET INSTALLER FOR CABINET INSTALLATION. CONTRACTOR TO ROUTE UTILITIES THROUGH CABINETS. CONTACT CABINET INSTALLER FOR SITE SPECIFIC CABINET SHOP DRAWINGS. E. GENERAL CONTRACTOR TO CONFIRM EQUIPMENT REQUIREMENTS PER GLOBAL ALLIANCE PM OR OWNER PRIOR TO INSTALLATION OF UTILITIES, WALLS, AND CABINETS. F. CONTRACTOR SHALL REPAIR EXISTING EXTERIOR SOFFIT FROM REMOVAL OF OLD 'ampm' SIGN PANEL SYSTEM TO PROVIDE A CLEAN, SMOOTH SURFACE FOR THE NEW "ampm" GRAPHICS INSTALLATION. G. WALL COVERINGS, WHERE REQUIRED, SHALL BE INSTALLED BY THE GENERAL CONTRACTOR ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. H. ALL EXISTING PASSAGE DOORS TO BE 36" MIN. WIDTH. I. CONTRACTOR SHALL ASSIST THE PM WITH EQUIPMENT DELIVERY TO PREPARE A DELIVERY AND STAGING AREA. COORDINATE WITH GLOBAL ALLIANCE PM OR OWNER FOR THE DELIVERY SCHEDULE AND ANY SHIPPING DAMAGES, IF APPLICABLE. J. THE STORE SHALL BE FINISHED ACCORDING TO THE FINISH SCHEDULE ON INTERIOR ELEVATIONS ON A.2.3 THRU A.2.5. REVIEW FINISH AREAS WITH GLOBAL ALLIANCE PM OR OWNER. K. CONTRACTOR SHALL ASSIST STORE PERSONNEL BY ASSEMBLING MERCHANDISE GONDOLAS AND SHELVING AS SHOWN ON Q1.1. L. HVAC CONDENSATE TO DRAIN TO FLOOR SINKS (VERIFY EXISTING COND)T|0NS ' M. ALL EXISTING SURFACES AND EQUIPMENT REMAINING MUST BE CLEANED PROPERLY, PRIOR TO OPENING. N. ALL NEW EQUIPMENT AND CABINETS SHALL BE FREE OF SHARP EDGES. CONTACT MANUFACTURER OR PREP EDGES FOR SAFETY. N. FIRE EXTINGUISHERS SHALL BE INSTALLED AT SALES COUNTER, KITCHEN, AND BACK OFFICE LOCATIONS IF NOT EXISTING. VERIFY WITH GLOBAL ALLIANCE PM OR OWNER FOR DETAILS. CONFIRM FINAL DETAILS WITH LOCAL FIRE INSPECTOR. O. EXISTING WATER HEATER SHALL BE CAPABLE OF DELIVERING MIN. 120^ WATER TO ALL SINKS. P. THE CONTRACTOR SHALL VERIFY LOCATIONS OF ALL FOOD SERVICE EQUIPMENT AND COORDINATE LOCATION OF FLOOR S|NK3, FLOOR DRA|NS, SLOPES/SLAB DEPRESSIONS AND RAISED CURBS, ELECTRICAL AND PLUMBING STUBOUTS, AND ALL OTHER WORK UNDER THIS SCOPE OF RESPONSIBILITY RELATED TO THIS EQUIPMENT. Q. ALL DOORS MUST HAVE A SWEEP PERIOD OF 3 SECONDS TO CLOSE FROM 70^ OPEN TO 3" FROM THE LATCH. R. ALL EXTERIOR DOORS MUST HAVE NO MORE THAN 5 LBS OPENING FORCE. ALL INTERIOR DOORS MUST HAVE NO MORE THAN 5 LBS OPENING FORCE. S. FLAME SPREAD CLASSIFICATIONS FOR INTERIOR WALLS SHALL COMPLY WITH 2000 IBC 803.5. T. REST ROOM DOOR SHALL HAVE HEAVY DUTY CLOSER AND LATCH. V. CARBONATOR BACKFLOW PREVENTER DRAIN LINE OUTLET SHALL BE TO NEW FLOOR SINK PROVIDED FOR THIS AREA. WALL FINISHES - REFERENCE SHEET A2.3, A2.4 AND A2.5 FOR MORE 1. EXISTING WALLS ARE SHEET METAL WALL PANELS/TS COLUMNS. NEW WALLS TO BE METAL w/ 5 /8" GYP. BOARD AND THE FOLLOWING FINISHES: I | PT | | (EXIST) EXISTING . . I FRP-1 | | pT | I | I | | | Es | STAINLESS STEEL - PARTIAL HEIGHT/FULL HEIGHT AT HOOD VV ' /NF � WALL LEGEND NEW STUD WALL (STD. 2 1/2" 3-5/8" & 6" WIDE X 1-5/8", SEE F EXISTING WALL (3" STANDING SEAM AND SHEET METAL PANELS, V.I.F.) [X0TN� RNNTED WALLS. REPAINT PER COLORS SHOWN ON INTERIOR ELEVATIONS PAINTED WALLS. PAINT PER COLORS SHOWN ON INTERIOR ELEVATIONS FIBERGLASS WALL PANELS, EMBOSSED SURFACE, COLOR WHITE (FULL HEIGHT) FIBERGLASS WALL PANELS, EMBOSSED SURFAC[, COLOR WHITE (FULL HEIGHT) - MATCH EXISTING NEW WALL FRAMING 1.25 GA. METAL STUDS INTERIOR FRAMING, 20 GA. EXTERIOR. 2. Al NEW WALLS TO BE BRACED IN ATTIC © 4'-0" 0.C. OR EACH END, IF LESS THAN 4' IN LENGTH. (SEE 03/A1.1A FOR TYPICAL STUD WALL) 3. ALL MATERIALS TO BE ICBO APPROVED/ICC APPROVED KEYED NOTES 0 ALL DOORS IN THE MEANS OF EGRESS SHALL BE OPERABLE FROM EGRESS SIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT; THE UNLATCHING OF ANY DOOR SHALL NOT REQUIRE MORE THAN ONE OPERATION. /7:;\ FOR GROUP M OCCUPANCY , KEY-OPERATED LOCKING DEVICES, DEVICES, FROM THE \�� �� EGRESS SIDE MAY BE USED ON THE MAIN EXTERIOR DOORS PROVIDED; A. THE LOCKING DEVICE IS READILY DISTINGUISHABLE LOCKED; AND; B. THERE IS A READILY VISIBLE DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR SHALL REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED"; AND; C. THIS SIGN SHALL BE IN LETTERS NOT LESS THAT 1-INCH HIGH ON A CONTRASTING BACKGROUND; AND; ' ` D. THE USE OF THIS EXCEPTION MAY BE REVOKED BY THE BUILDING OFFICIAL AT ANY TIME FOR DUE CAUSE. 0 NOT USED /,�� CONTRACTOR TO PROTECT MACHINE, LOCATION TO REMAIN. ^ KdANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED ON DOORS. EXISTING SALES CABINET. NEW COUNTERTOPS AND RACKING DESIGNS ARE BY �0� IMPRESSIONS MARKETING GROUP, INC. (703) 550-2211' OWNER MAY PURCHASE FROM `' IMPRESSIONS/SHOPCO OR PROVIDE APPROVED EQUAL. ALTERNATIVE APPROVAL TO BE OBTAINED FROM BP PRIOR TO PURCHASE. ��� \/� NOT USED ��� �o� CLEAR PLASTIC CORNER GUARDS /�7` GC TO VERIFY EXISTING ELECTRICAL FOR SIGN IS ADEQUATE FOR NEW. / ' QO> NOT USED ��� = C0NTRACTOR TO ASSIST IN RELOCATION OR INSTALLATION OF NEW SAFE(S). CONTACT \n/ SAFE VENDOR FOR DETAILS. SAFE MUST BE SECURED TO FLOOR WITH CONCRETE ANCHORS. BOLTS MUST BE TACT WELDED INSIDE SAFE FOR SECURITY. NOT USED RECEIVED CITY OF TUKVVILA [ JUL �70OO ,.� ~ �vv^ PERMIT CENTER Existing Room Finish Schedule �� Proposed Room Finish v�~�o ev�v�� m LOCATION LOCATION tn FLOOR BASE WALLS CEILING PREFINISHED PREFAB PANELS HARDENED CONC. 3111 1ANIA 3111 OUN I30 6" VINYL COVE 6" CERAMIC COVE 6" METAL COVE 5/8" GYPSUM BOARD SHEET METAL PANELS PREFINISHED FRP PANELS '0B 'dA0 ,X. 3dA1 "8 /S STAINLESS STEEL TYPE 304 SUSP. GYPSUM PANELS 5/8" GYP. BOARD SHEET METAL PANELS 5/8" TYPE "X" GYPSUM BOARD 1HOI3H PREFAB COOLER o e 0 ±8' SALES AREA ±a' SALES AREA 0 0 0 0 0 e 0 0 0 ± 1 o' NEW UNISEX REST ROOM � • � • *o vm wp 8'-11^ OFFICE � 0 � OFFICE 0 0 y9'--5n FOOD PREP AREA o y9 FOOD PREP AREA o e 0 0 0 • BACK ROOM 0 0 • 0 ±10' BACK ROOM 0 e 0 0 e 0 w* 0 0 ±9' EXISTING 6" TS. COLUMNS SAW CUT PAVEMENT AND PROVIDE 6" THICK SLAB ON GRADE w/ #4 40 12" O.C. EA WAY @ CENTER OF SLAB OVER 8" OF COMPACTED, CLEAN. OPEN-GRADED COARSE ROCK. USE 10 MIL VAPOR BARRIER OVER COMPACTED ROCK. (MATCH EXISTING SALES ROOM ELEVATION) � A1.1A EXISTING OFFICE PT indr (NEW) FRP-1 NEW 8S (NEW) ENCROACH INTO REQUIRED 30" WIDE LAV SPACE. 34" DOOR --` FRP-1 '^^ (NEW) FINISH CUT SIDE OF WALL, SEE SECT. A1.1A �--NEW SOFFIT PORTION, FINISH CUT SIDE TO {}2 MATCH EXISTING ADJACENT SOFFIT / EXIS BACK � SEE SH FOR TYPICAL 8ACI1R{X}M EQUIP EXISTING STORAGE EXISTING WIRE GLAZING TO REMAIN - " J/ J ' / _� HAND SINK EXISTING pT | COFFEE/FOUNTAIN (EXIST) -'' - | -°r—�- CAL BACKROOM E 5'-6" OPENING A1.1A w ALIGN FACE MTL STUD WALL WITH SALES ROOM SIDE OF EXISTING 3" METAL SOFFIT ABV., SEE SECTION A1.1A A.2.4 EXISTING SALES AREA EXISTING | PT \/ CASHIER � )B0�� � (EXIST) EXISTING WIRE GLAZING TO REMAIN (EXIST) EXISTING COOLER -H EXISTING TRASH CONSTRUCTION FLOOR PLAN SCALE: 1/ � 1'—O" .,`" -�. .� -r w . . EXISTING STORAGE CONTAINER INTERIOR ELEVATION MARKER � /u`�/. `_��_vr` //.//� /v/,`/`u` DETAIL NUMBER SHEET NUMBER 01 03 6" ST. x , ' FINISH VARIES, REFER TO INTERIOR ELEVATIONS SUBSTRATE )i" GYB. 8D. WATER RESISTANT @ SINKS TYP. BOTH SIDES .'�• •` ` `• `,• METAL STUD @ 16" O.C. REVIEWED { JUL CODE COMPLIANCE "-FINISH VARIES, REFER TO INTERIOR ELEVATIONS GYP,' BD, BOTH SIDES AT DRY CONDITIONS PLAN DRYWALL: 1. INSTALL GYPSUM BOARD IN ACCORDANCE WITH RECOMMENDATIONS OF GYPSUM ASSOCIATION {Ar216. FLAME SPREAD CLASS: 2. SCREWS: SELF-DRILLING, SELF-TAPPING, TYPE "5". SIZES ARE RECOMMENDED BY GYPSUM BOARD MANUFACTURER FOR WALL AND CEILING APPLICATIONS. City of ���v�V VK8kwila F3NALDUNG DIVISION GENERAL NOTES A. CONTRACTOR SHALL INSTALL NEW PARTITIONS WITH DRY WALL AND FINISHES TO MATCH EXISTING OR AS NOTED. FINISHES MUST BE SMOOTH, LIGHT, AND WASHABLE, I.E., RESTISTANT TO MOISTURE. ALL NEW PARTITIONS SHALL BE BRACED FOR LATERAL FORCES, PER BUILDING CODE REQUIREMENTS. B. ALL DIMENSIONS SHALL BE FIELD VERIFIED BY CONTRACTOR FROM CABINET AND EQUIPMENT CLEARANCES PRIOR TO WALL ERECTION. DISCREPANCIES SHALL BE DIRECTED TO GLOBAL ALLIANCE PM OR OWNER. C. DIMENSIONS OF NEW WALLS ARE FROM FACE OF STUD. DIMENSIONS FROM EXISTING WALLS ARE FROM FINISHED FACE. D. ALL COUNTERTOPS SHAL BE MAX. 34" A.F.F. CONTRACTOR SHALL COORDINATE WORK WITH CABINET INSTALLER FOR CABINET INSTALLATION. CONTRACTOR TO ROUTE UTILITIES THROUGH CABINETS. CONTACT CABINET INSTALLER FOR SITE SPECIFIC CABINET SHOP DRAWINGS. E. GENERAL CONTRACTOR TO CONFIRM EQUIPMENT REQUIREMENTS PER GLOBAL ALLIANCE PM OR OWNER PRIOR TO INSTALLATION OF UTILITIES, WALLS, AND CABINETS. F. CONTRACTOR SHALL REPAIR EXISTING EXTERIOR SOFFIT FROM REMOVAL OF OLD 'ampm' SIGN PANEL SYSTEM TO PROVIDE A CLEAN, SMOOTH SURFACE FOR THE NEW "ampm" GRAPHICS INSTALLATION. G. WALL COVERINGS, WHERE REQUIRED, SHALL BE INSTALLED BY THE GENERAL CONTRACTOR ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. H. ALL EXISTING PASSAGE DOORS TO BE 36" MIN. WIDTH. I. CONTRACTOR SHALL ASSIST THE PM WITH EQUIPMENT DELIVERY TO PREPARE A DELIVERY AND STAGING AREA. COORDINATE WITH GLOBAL ALLIANCE PM OR OWNER FOR THE DELIVERY SCHEDULE AND ANY SHIPPING DAMAGES, IF APPLICABLE. J. THE STORE SHALL BE FINISHED ACCORDING TO THE FINISH SCHEDULE ON INTERIOR ELEVATIONS ON A.2.3 THRU A.2.5. REVIEW FINISH AREAS WITH GLOBAL ALLIANCE PM OR OWNER. K. CONTRACTOR SHALL ASSIST STORE PERSONNEL BY ASSEMBLING MERCHANDISE GONDOLAS AND SHELVING AS SHOWN ON Q1.1. L. HVAC CONDENSATE TO DRAIN TO FLOOR SINKS (VERIFY EXISTING COND)T|0NS ' M. ALL EXISTING SURFACES AND EQUIPMENT REMAINING MUST BE CLEANED PROPERLY, PRIOR TO OPENING. N. ALL NEW EQUIPMENT AND CABINETS SHALL BE FREE OF SHARP EDGES. CONTACT MANUFACTURER OR PREP EDGES FOR SAFETY. N. FIRE EXTINGUISHERS SHALL BE INSTALLED AT SALES COUNTER, KITCHEN, AND BACK OFFICE LOCATIONS IF NOT EXISTING. VERIFY WITH GLOBAL ALLIANCE PM OR OWNER FOR DETAILS. CONFIRM FINAL DETAILS WITH LOCAL FIRE INSPECTOR. O. EXISTING WATER HEATER SHALL BE CAPABLE OF DELIVERING MIN. 120^ WATER TO ALL SINKS. P. THE CONTRACTOR SHALL VERIFY LOCATIONS OF ALL FOOD SERVICE EQUIPMENT AND COORDINATE LOCATION OF FLOOR S|NK3, FLOOR DRA|NS, SLOPES/SLAB DEPRESSIONS AND RAISED CURBS, ELECTRICAL AND PLUMBING STUBOUTS, AND ALL OTHER WORK UNDER THIS SCOPE OF RESPONSIBILITY RELATED TO THIS EQUIPMENT. Q. ALL DOORS MUST HAVE A SWEEP PERIOD OF 3 SECONDS TO CLOSE FROM 70^ OPEN TO 3" FROM THE LATCH. R. ALL EXTERIOR DOORS MUST HAVE NO MORE THAN 5 LBS OPENING FORCE. ALL INTERIOR DOORS MUST HAVE NO MORE THAN 5 LBS OPENING FORCE. S. FLAME SPREAD CLASSIFICATIONS FOR INTERIOR WALLS SHALL COMPLY WITH 2000 IBC 803.5. T. REST ROOM DOOR SHALL HAVE HEAVY DUTY CLOSER AND LATCH. V. CARBONATOR BACKFLOW PREVENTER DRAIN LINE OUTLET SHALL BE TO NEW FLOOR SINK PROVIDED FOR THIS AREA. WALL FINISHES - REFERENCE SHEET A2.3, A2.4 AND A2.5 FOR MORE 1. EXISTING WALLS ARE SHEET METAL WALL PANELS/TS COLUMNS. NEW WALLS TO BE METAL w/ 5 /8" GYP. BOARD AND THE FOLLOWING FINISHES: I | PT | | (EXIST) EXISTING . . I FRP-1 | | pT | I | I | | | Es | STAINLESS STEEL - PARTIAL HEIGHT/FULL HEIGHT AT HOOD VV ' /NF � WALL LEGEND NEW STUD WALL (STD. 2 1/2" 3-5/8" & 6" WIDE X 1-5/8", SEE F EXISTING WALL (3" STANDING SEAM AND SHEET METAL PANELS, V.I.F.) [X0TN� RNNTED WALLS. REPAINT PER COLORS SHOWN ON INTERIOR ELEVATIONS PAINTED WALLS. PAINT PER COLORS SHOWN ON INTERIOR ELEVATIONS FIBERGLASS WALL PANELS, EMBOSSED SURFACE, COLOR WHITE (FULL HEIGHT) FIBERGLASS WALL PANELS, EMBOSSED SURFAC[, COLOR WHITE (FULL HEIGHT) - MATCH EXISTING NEW WALL FRAMING 1.25 GA. METAL STUDS INTERIOR FRAMING, 20 GA. EXTERIOR. 2. Al NEW WALLS TO BE BRACED IN ATTIC © 4'-0" 0.C. OR EACH END, IF LESS THAN 4' IN LENGTH. (SEE 03/A1.1A FOR TYPICAL STUD WALL) 3. ALL MATERIALS TO BE ICBO APPROVED/ICC APPROVED KEYED NOTES 0 ALL DOORS IN THE MEANS OF EGRESS SHALL BE OPERABLE FROM EGRESS SIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT; THE UNLATCHING OF ANY DOOR SHALL NOT REQUIRE MORE THAN ONE OPERATION. /7:;\ FOR GROUP M OCCUPANCY , KEY-OPERATED LOCKING DEVICES, DEVICES, FROM THE \�� �� EGRESS SIDE MAY BE USED ON THE MAIN EXTERIOR DOORS PROVIDED; A. THE LOCKING DEVICE IS READILY DISTINGUISHABLE LOCKED; AND; B. THERE IS A READILY VISIBLE DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR SHALL REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED"; AND; C. THIS SIGN SHALL BE IN LETTERS NOT LESS THAT 1-INCH HIGH ON A CONTRASTING BACKGROUND; AND; ' ` D. THE USE OF THIS EXCEPTION MAY BE REVOKED BY THE BUILDING OFFICIAL AT ANY TIME FOR DUE CAUSE. 0 NOT USED /,�� CONTRACTOR TO PROTECT MACHINE, LOCATION TO REMAIN. ^ KdANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED ON DOORS. EXISTING SALES CABINET. NEW COUNTERTOPS AND RACKING DESIGNS ARE BY �0� IMPRESSIONS MARKETING GROUP, INC. (703) 550-2211' OWNER MAY PURCHASE FROM `' IMPRESSIONS/SHOPCO OR PROVIDE APPROVED EQUAL. ALTERNATIVE APPROVAL TO BE OBTAINED FROM BP PRIOR TO PURCHASE. ��� \/� NOT USED ��� �o� CLEAR PLASTIC CORNER GUARDS /�7` GC TO VERIFY EXISTING ELECTRICAL FOR SIGN IS ADEQUATE FOR NEW. / ' QO> NOT USED ��� = C0NTRACTOR TO ASSIST IN RELOCATION OR INSTALLATION OF NEW SAFE(S). CONTACT \n/ SAFE VENDOR FOR DETAILS. SAFE MUST BE SECURED TO FLOOR WITH CONCRETE ANCHORS. BOLTS MUST BE TACT WELDED INSIDE SAFE FOR SECURITY. NOT USED RECEIVED CITY OF TUKVVILA [ JUL �70OO ,.� ~ �vv^ PERMIT CENTER Existing Room Finish Schedule m LOCATION FLOOR BASE WALLS CEILING PREF1NISHED PREFAB PANELS 'ONOO 03N3021YH 3111 1ANIA 31I1 0114%213O 6" VINYL COVE 6" CERAMIC COVE 6" METAL COVE L 5/8" GYPSUM BOARD SHEET METAL PANELS S13NVd d2il 03HSINL4321d 5/8" TYPE 'X' GYP. BD. STAINLESS STEEL TYPE 304 SUSP. GYPSUM PANELS 5/8" GYP. BOARD SHEET METAL PANELS 5/8" TYPE "X" GYPSUM BOARD 1HOI3H PREFAB COOLER • o e 0 ±8' SALES AREA 0 0 0 0 e ±1o' EMPLOYEE REST ROOM 0 • 0 • o 8'-11^ OFFICE 0 0 0 0 y9'--5n FOOD PREP AREA o o o e e ±9' BACK ROOM • 0 0 e o e ±9' EXISTING 6" TS. COLUMNS SAW CUT PAVEMENT AND PROVIDE 6" THICK SLAB ON GRADE w/ #4 40 12" O.C. EA WAY @ CENTER OF SLAB OVER 8" OF COMPACTED, CLEAN. OPEN-GRADED COARSE ROCK. USE 10 MIL VAPOR BARRIER OVER COMPACTED ROCK. (MATCH EXISTING SALES ROOM ELEVATION) � A1.1A EXISTING OFFICE PT indr (NEW) FRP-1 NEW 8S (NEW) ENCROACH INTO REQUIRED 30" WIDE LAV SPACE. 34" DOOR --` FRP-1 '^^ (NEW) FINISH CUT SIDE OF WALL, SEE SECT. A1.1A �--NEW SOFFIT PORTION, FINISH CUT SIDE TO {}2 MATCH EXISTING ADJACENT SOFFIT / EXIS BACK � SEE SH FOR TYPICAL 8ACI1R{X}M EQUIP EXISTING STORAGE EXISTING WIRE GLAZING TO REMAIN - " J/ J ' / _� HAND SINK EXISTING pT | COFFEE/FOUNTAIN (EXIST) -'' - | -°r—�- CAL BACKROOM E 5'-6" OPENING A1.1A w ALIGN FACE MTL STUD WALL WITH SALES ROOM SIDE OF EXISTING 3" METAL SOFFIT ABV., SEE SECTION A1.1A A.2.4 EXISTING SALES AREA EXISTING | PT \/ CASHIER � )B0�� � (EXIST) EXISTING WIRE GLAZING TO REMAIN (EXIST) EXISTING COOLER -H EXISTING TRASH CONSTRUCTION FLOOR PLAN SCALE: 1/ � 1'—O" .,`" -�. .� -r w . . EXISTING STORAGE CONTAINER INTERIOR ELEVATION MARKER � /u`�/. `_��_vr` //.//� /v/,`/`u` DETAIL NUMBER SHEET NUMBER 01 03 6" ST. x , ' FINISH VARIES, REFER TO INTERIOR ELEVATIONS SUBSTRATE )i" GYB. 8D. WATER RESISTANT @ SINKS TYP. BOTH SIDES .'�• •` ` `• `,• METAL STUD @ 16" O.C. REVIEWED { JUL CODE COMPLIANCE "-FINISH VARIES, REFER TO INTERIOR ELEVATIONS GYP,' BD, BOTH SIDES AT DRY CONDITIONS PLAN DRYWALL: 1. INSTALL GYPSUM BOARD IN ACCORDANCE WITH RECOMMENDATIONS OF GYPSUM ASSOCIATION {Ar216. FLAME SPREAD CLASS: 2. SCREWS: SELF-DRILLING, SELF-TAPPING, TYPE "5". SIZES ARE RECOMMENDED BY GYPSUM BOARD MANUFACTURER FOR WALL AND CEILING APPLICATIONS. City of ���v�V VK8kwila F3NALDUNG DIVISION GENERAL NOTES A. CONTRACTOR SHALL INSTALL NEW PARTITIONS WITH DRY WALL AND FINISHES TO MATCH EXISTING OR AS NOTED. FINISHES MUST BE SMOOTH, LIGHT, AND WASHABLE, I.E., RESTISTANT TO MOISTURE. ALL NEW PARTITIONS SHALL BE BRACED FOR LATERAL FORCES, PER BUILDING CODE REQUIREMENTS. B. ALL DIMENSIONS SHALL BE FIELD VERIFIED BY CONTRACTOR FROM CABINET AND EQUIPMENT CLEARANCES PRIOR TO WALL ERECTION. DISCREPANCIES SHALL BE DIRECTED TO GLOBAL ALLIANCE PM OR OWNER. C. DIMENSIONS OF NEW WALLS ARE FROM FACE OF STUD. DIMENSIONS FROM EXISTING WALLS ARE FROM FINISHED FACE. D. ALL COUNTERTOPS SHAL BE MAX. 34" A.F.F. CONTRACTOR SHALL COORDINATE WORK WITH CABINET INSTALLER FOR CABINET INSTALLATION. CONTRACTOR TO ROUTE UTILITIES THROUGH CABINETS. CONTACT CABINET INSTALLER FOR SITE SPECIFIC CABINET SHOP DRAWINGS. E. GENERAL CONTRACTOR TO CONFIRM EQUIPMENT REQUIREMENTS PER GLOBAL ALLIANCE PM OR OWNER PRIOR TO INSTALLATION OF UTILITIES, WALLS, AND CABINETS. F. CONTRACTOR SHALL REPAIR EXISTING EXTERIOR SOFFIT FROM REMOVAL OF OLD 'ampm' SIGN PANEL SYSTEM TO PROVIDE A CLEAN, SMOOTH SURFACE FOR THE NEW "ampm" GRAPHICS INSTALLATION. G. WALL COVERINGS, WHERE REQUIRED, SHALL BE INSTALLED BY THE GENERAL CONTRACTOR ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. H. ALL EXISTING PASSAGE DOORS TO BE 36" MIN. WIDTH. I. CONTRACTOR SHALL ASSIST THE PM WITH EQUIPMENT DELIVERY TO PREPARE A DELIVERY AND STAGING AREA. COORDINATE WITH GLOBAL ALLIANCE PM OR OWNER FOR THE DELIVERY SCHEDULE AND ANY SHIPPING DAMAGES, IF APPLICABLE. J. THE STORE SHALL BE FINISHED ACCORDING TO THE FINISH SCHEDULE ON INTERIOR ELEVATIONS ON A.2.3 THRU A.2.5. REVIEW FINISH AREAS WITH GLOBAL ALLIANCE PM OR OWNER. K. CONTRACTOR SHALL ASSIST STORE PERSONNEL BY ASSEMBLING MERCHANDISE GONDOLAS AND SHELVING AS SHOWN ON Q1.1. L. HVAC CONDENSATE TO DRAIN TO FLOOR SINKS (VERIFY EXISTING COND)T|0NS ' M. ALL EXISTING SURFACES AND EQUIPMENT REMAINING MUST BE CLEANED PROPERLY, PRIOR TO OPENING. N. ALL NEW EQUIPMENT AND CABINETS SHALL BE FREE OF SHARP EDGES. CONTACT MANUFACTURER OR PREP EDGES FOR SAFETY. N. FIRE EXTINGUISHERS SHALL BE INSTALLED AT SALES COUNTER, KITCHEN, AND BACK OFFICE LOCATIONS IF NOT EXISTING. VERIFY WITH GLOBAL ALLIANCE PM OR OWNER FOR DETAILS. CONFIRM FINAL DETAILS WITH LOCAL FIRE INSPECTOR. O. EXISTING WATER HEATER SHALL BE CAPABLE OF DELIVERING MIN. 120^ WATER TO ALL SINKS. P. THE CONTRACTOR SHALL VERIFY LOCATIONS OF ALL FOOD SERVICE EQUIPMENT AND COORDINATE LOCATION OF FLOOR S|NK3, FLOOR DRA|NS, SLOPES/SLAB DEPRESSIONS AND RAISED CURBS, ELECTRICAL AND PLUMBING STUBOUTS, AND ALL OTHER WORK UNDER THIS SCOPE OF RESPONSIBILITY RELATED TO THIS EQUIPMENT. Q. ALL DOORS MUST HAVE A SWEEP PERIOD OF 3 SECONDS TO CLOSE FROM 70^ OPEN TO 3" FROM THE LATCH. R. ALL EXTERIOR DOORS MUST HAVE NO MORE THAN 5 LBS OPENING FORCE. ALL INTERIOR DOORS MUST HAVE NO MORE THAN 5 LBS OPENING FORCE. S. FLAME SPREAD CLASSIFICATIONS FOR INTERIOR WALLS SHALL COMPLY WITH 2000 IBC 803.5. T. REST ROOM DOOR SHALL HAVE HEAVY DUTY CLOSER AND LATCH. V. CARBONATOR BACKFLOW PREVENTER DRAIN LINE OUTLET SHALL BE TO NEW FLOOR SINK PROVIDED FOR THIS AREA. WALL FINISHES - REFERENCE SHEET A2.3, A2.4 AND A2.5 FOR MORE 1. EXISTING WALLS ARE SHEET METAL WALL PANELS/TS COLUMNS. NEW WALLS TO BE METAL w/ 5 /8" GYP. BOARD AND THE FOLLOWING FINISHES: I | PT | | (EXIST) I FRP-1 | | pT | I | I | | | Es | EXISTING PAINTED WALLS. PAINT PER COLORS SHOWN ON INTERIOR ELEVATIONS FIBERGLASS WALL PANELS, EMBOSSED SURFACE, COLOR WHITE (FULL HEIGHT) FIBERGLASS WALL PANELS, EMBOSSED SURFAC[, COLOR WHITE (FULL HEIGHT) - MATCH EXISTING NEW WALL FRAMING 1.25 GA. METAL STUDS INTERIOR FRAMING, 20 GA. EXTERIOR. 2. Al NEW WALLS TO BE BRACED IN ATTIC © 4'-0" 0.C. OR EACH END, IF LESS THAN 4' IN LENGTH. (SEE 03/A1.1A FOR TYPICAL STUD WALL) 3. ALL MATERIALS TO BE ICBO APPROVED/ICC APPROVED KEYED NOTES 0 ALL DOORS IN THE MEANS OF EGRESS SHALL BE OPERABLE FROM EGRESS SIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT; THE UNLATCHING OF ANY DOOR SHALL NOT REQUIRE MORE THAN ONE OPERATION. /7:;\ FOR GROUP M OCCUPANCY , KEY-OPERATED LOCKING DEVICES, DEVICES, FROM THE \�� �� EGRESS SIDE MAY BE USED ON THE MAIN EXTERIOR DOORS PROVIDED; A. THE LOCKING DEVICE IS READILY DISTINGUISHABLE LOCKED; AND; B. THERE IS A READILY VISIBLE DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR SHALL REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED"; AND; C. THIS SIGN SHALL BE IN LETTERS NOT LESS THAT 1-INCH HIGH ON A CONTRASTING BACKGROUND; AND; ' ` D. THE USE OF THIS EXCEPTION MAY BE REVOKED BY THE BUILDING OFFICIAL AT ANY TIME FOR DUE CAUSE. 0 NOT USED /,�� CONTRACTOR TO PROTECT MACHINE, LOCATION TO REMAIN. ^ KdANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED ON DOORS. EXISTING SALES CABINET. NEW COUNTERTOPS AND RACKING DESIGNS ARE BY �0� IMPRESSIONS MARKETING GROUP, INC. (703) 550-2211' OWNER MAY PURCHASE FROM `' IMPRESSIONS/SHOPCO OR PROVIDE APPROVED EQUAL. ALTERNATIVE APPROVAL TO BE OBTAINED FROM BP PRIOR TO PURCHASE. ��� \/� NOT USED ��� �o� CLEAR PLASTIC CORNER GUARDS /�7` GC TO VERIFY EXISTING ELECTRICAL FOR SIGN IS ADEQUATE FOR NEW. / ' QO> NOT USED ��� = C0NTRACTOR TO ASSIST IN RELOCATION OR INSTALLATION OF NEW SAFE(S). CONTACT \n/ SAFE VENDOR FOR DETAILS. SAFE MUST BE SECURED TO FLOOR WITH CONCRETE ANCHORS. BOLTS MUST BE TACT WELDED INSIDE SAFE FOR SECURITY. NOT USED RECEIVED CITY OF TUKVVILA [ JUL �70OO ,.� ~ �vv^ PERMIT CENTER MARK QTY ITEM MANUF. ID. # DESCRIPTION CHECKED BY: 1 TOILET PAPER DISP. BY OTHERS #B 2111 SINGLE ROLL (SURFACE MOUNT.), SATIN FINISH A SHEET NO: i lA 1 MIRROR BOBRICK #8 0 65 183 0 18X30 STAINLESS STEEL FRAMED MIRROR 1 UTILITY HOOK BOBRICK #B -6707 SATIN FINISH STAINLESS STEEL [ I 1 GRAB BAR BOBRICK #B -6806. 99x42 1 1/2" DIA. CONCEALED MOUNTING, SATIN FINISH D SOAP DISPENSER BOBRICK #B-2111 WALL MOUNTED, SATAN FINISH, STAINLESS STEEL CONTAINER, VANDAL - RESISTANT LID, STAINLESS STEEL LATHER VALVE, CAPACITY: 40 FL. OZ 1 SANIT. NAPKIN DISP. BOBRICK #B -270 (1 �I`"'�I 1 PAPER TOWEL DISP. / WASTE RECEPTACLE BOBRICK #B -3944 RECESSED COMBINATION PAPER TOWEL DISPENSER AND WASTE RECEPTACLE 1 GRAB BAR BOBRICK #B -6806. 99x18 1 1/2" DIA. CONCEALED MOUNTING, SATIN FINISH H 1 GRAB BAR BOBRICK #B -6806. 99x36 1 1/2" DIA. CONCEALED MOUNTING, SATIN FINISH j 1 BABY CHANGING STATION KOALA VERTICAL STYLE VERTICAL WALL MOUNTED BABY CHANGING STATION, 40" ABV. FLR. IN OPEN POSITION K DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: ALLIANCE Z&DM: CHECKED BY: BP REPM: DRAWN BY: ALLIANCE PM: VERSION: _ PROJECT NO: 1975.75 DRAWING TITLE: MISCELLANEOUS WALL DETAILS SHEET NO: i lA 18" MIN FRP -3 REMOVE AREA OF WALL SHOWN HATCHED TO 7' -0" ABV. FIN. FLOOR WB -1 EXISTING 2" POWER CONDUIT FROM PANEL B TO MSB w/ i CONDUIT BELOW, TO REMAIN 15.080 ELEVATION @ BACKROOM WALL REMOVAL SCALE: 1/2" = 1' -0" FINISH VARIES, REFER TO INTERIOR ELEVATIONS %6" GYP. BD. BOTH SIDES AT DRY CONDITIONS METAL RUNNER / /• / / / / / / / �/ I . n.�_... L.. / / / • /I / / , / / / . 1 / , I / / , / 1 /// /.//// / / / / / . / / r / • // 7 / / / / / , r ,7 • ' /f % ' / / / / f , • / / f • / / • 7 f 7 / / / / f f / / / / / / f � // / / / / / 7 r , / / ; / ' ' / • / / / ' / r / , /. /d • . / f / /7 ,/ / / 4 , 7. ' / / / • 7 / / / '/ • / `` / / .'`` / ", / , 7 / / , / / / 75 , ,. / 7 7 / ,. / , / / i / 7 / 7 • / / / / :` A uuuuuuuuumu� uuHuuuuuuuu TYPICAL STUD WALL SCALE: NTS N m z / EXISTING 3' OP'G TO BACKROOM EXISTING STEEL SUPPORT SYSTEM LOCATION OF NEW WALL(S) VARY, 20GA BRACING © 4' -0" O.C., REFER TO FLOOR PLAN FAI El SEE NOTE 2 ON SHEET A1.1. ■ ; El ' FIRE BLOCKING AT CEILING ► IVA F L ■ FINISH VARIES, REFER TO INTERIOR ��� ELEVATIONS . 25GA METAL STUDS (SEE PLAN FOR `. 2 1/2 ", 3 -5/8" OR 6" WIDE FA 2Y" x 1Y64" 0 W/ % "0 HEAD, POWDER DRIVEN FASTENER SHOT illi THRU 14GA X 1316" 0 WASHER CD �i 24" O.C. (RAMSET 3337 OR HILTI DS72 OR EQUAL). A. ' ' . [1 • d EXISTING CONCRETE SLAB SECTION @ PERPENDICULAR SUBSTRATE Y2" GYP. BD. BOTH SIDES, WATER RESISTANT ® SINKS 111 ■11111■11■1■11111111■111■ ■11S■ I ■!'1 ■® ■■III■ ■ ■ ■■■ ■■ ■IIIII■■ I■■ ■■1■■■III■■■■■■U■■ ■II •UNSU ■ ■RU ■N ■ ■ ■U ■ ■ ■U ISM ■III■ ■ ■■ ■ ■■e ■ ■ ■ ■ ■ /.II 111 E11�■■■ ■11�■ �1 ■■__.IN mom 1111 11111.1�11■ ■ ■!!� ! za+� ® III �� it ■1 ■■ i■mI ■1511©■■■ 1111 ` B ■1111 G 111111 � ■■�/ i11 � 11111 ■■■1111111/■ Mil „ 1111- ■ ■■� 1ua1,MIE �u►' � ' i■IR■ � ■ __ E 1I �71e11 � iil� l ■■lil■ 11110=11111111 micomisrai 1■1m Iii■ ■11 miaiii111111111.1 I■ %II■■■H L9 I Al 1I/ ■■11111- - - ICI► r MIMI illi ■ N z 1' -6" FRP -3 WB -1 x 0 I c) 06.113 5.080 EXISTING ACOUSTIC CEILING © ±8' -4" ABV. FIN. FLR. EDGE OF EXISTING CASED OPENING j PROVIDE SHEET METAL COVER OVER CUT, RIVET PROVIDE NEW VINYL TILE FLOOR, SEE A1.2 REMOVE EXISTING CEILING WITHIN SOFFIT AREA PER PLAN ii _J I ii I 3r METAL p1'UDS © 16" O.C., 25GA I ( ULTRASTEEL" OR EQUAL) INSTALL SOUND BATT 'INSULATION 2' -5 1/2" I ADDITION NEW RESTROOM i" GYP. Bd. I(WATER RESISTIVE 0 ;SINKS & WATER CLOSET) i I "i i 1 5 -21 NEW R38 BATT INSULATION BACKROOM ENTRAN EXISTING INSULATED ATTIC SPACE EXISTING SLAB OVERLAY EXISTING SLAB SECTION THRU HALL & RESTROOM ADDITION SCALE: 1 /2" = 1' -0" m O A 7" MIN. * DIMENSION TO BOTTOM OF REFLECTIVE SURFACE EXISTING STORE ROOF I c) EXISTING 3" STEEL SOFFIT WALL TYPICAL INTERIOR REST ROOM ELEVATIONS - SEE PLAN FOR ACTUAL LOCATION OF FIXTURES /ACCESSORIES SCALE: 1 /2 = 1, -0.. 2Y X 1 Y64 " 0 W/ %6 "0 HEAD, POWDER DRIVEN FASTENER SHOT THRU 14GA X 1316" 0 WASHER 24" O.C. (RAMSET 3337 OR HILTI DS72 OR EQUAL). EXISTING HEADER FLASHING, UP WALL 6" MIN. H 06.113 m D Q FRP -3 l'-6" WB -1 WC1 - RIGHT HAND TRIP LEVER PROVIDE NEW 3" STANDING SEAM MTL ROOF; I" PLYWOOD; 30LB PAPER Sc ASPHALT SHINGLES TO MATCH EXISTING PROVIDE (1) 50SF ROOF VENT EXISTING SHED ROOF Sc VENT, BEYOND 2" METAL STUDS 0 24" O.C.; CEILING, w/ i GYP. BD. OVER REMOVE EXTERIOR WALL PER PLAN NEW R21 BATT INSULATION EXTERIOR WALL TREATMENT: i" PLYWOOD; WATER RESISTIVE BUILDING WRAP; 22GA EXT. METAL PANELS 6 "METAL STUDS CSI 16" O.C., 20GA ( "ULTRASTEEL" OR EQUAL) 2h" X 1 )/64" 0 W/ % "0 HEAD, POWDER DRIVEN FASTENER SHOT THRU 14GA X 1 i6" 0 WASHER 24" O.C. ( RAMSET 3337 OR HILTI DS72 OR EQUAL). PROVIDE FLASHING AT WALL BASE, UP WALL 12 ", EXTEND DOWN SLAB EDGE 2" MIN. NEW 6" THICK SLAB, PROVIDE #4 DOWL, 12" LONG, EMBED 6" INTO EXISTING SLAB © 18" O.C. #4 BARS @ 12" O.C. EA. WAY i" CEMENT PLASTER, SEE ELEVATION FOR LIMITS " PLYWOOD OVER WEATHER PROOF MEMBRANE INFILL SPACE BETWEEN EXISTING COLUMNS WITH METAL STUDS, SEE A1.1 " GYP. BD. AT INTERIOR MEM MEM MIME MEM MEM IMMMIII A • FRP -3 WB -1 W 0 0 0 Q I— v) NEW WALL AT/ FCB AREA P -1 SCALE: 1 /2" = 1' -0" R -21 BAIT INSULATION AT EXTERIOR WALL NEW R38 BATT INSULATION OVER EXPANDED SALES ROOM AREA 2Y2 X Y64 0 W/ % "0 HEAD, POWDER DRIVEN FASTENER SHOT THRU 14GA X 146" 0 WASHER CD 24" O.C. (RAMSET 3337 OR HILTI DS72 OR EQUAL). SECTION THRU PORCH /CEILING AREA REVIEWED FOR CODE COMPLIANCE APPP VED JUL 17 2009 City of Tukwila BUILDING DIVISION n EXISTING STANDING SEAM SHEET METAL CEILING TO REMAIN PROVIDE SUPPORT FROM FRONT OF STORE TO SOFFIT (APPROX. 12' IN LENGTH) FOR EXISTING AND NEW CEILINGS. - SOFFIT AND WALLS BEYOND J RECEIVED CITY OF TUKWILA JUL 0 „8 2009 PERMIT CENTER RESTROOM ACCESSORIES • A KEYED NOTES: O 06.113 CONTRACTOR TO PROVIDE BLOCKING AS REQUIRED FOR ALL ACCESSORIES AND SHELVING, DASHED LINES ON ELEVATIONS REPRESENT APPROXIMATE LOCATION OF BLOCKING. 06.196 CONTRACTOR TO SECURE SHELVING BRACKETS DIRECTLY TO STUD OR BLOCKING. 09.260 C- SHAPED CORNER GUARD TO BE 16GA STAINLESS STEEL 10.800 PAPER TOWEL AND SOAP DISPENSER. 15.080 PROVIDE ADA PIPE WRAP ON ALL EXPOSED PIPING. SUBSTRATE: GB-1 GB -2 PLY -1 PLY -2 WALL FINISH: FIBER REINFORCED PANEL COLOR: WHITE BY: KEMLITE (85) OR MARLITE (FRP S100G) COLOR: ALMOND TYPE: LASCO BOARD WP 4'x8' (0.090” THICK) COLOR: ALMOND TYPE: MARLITE C118 -G44, WITH SCORED GRID PATTERN WALL BASE COLOR: #130 "BUCKSKIN" BY: ROPPE SIZE: %8'x6" COVE BASE LOCATION: BACK ROOM FRP -1 FRP -2 FRP -3 V -1 WB -1 INTERIOR PAINTS: P -1 P -2 P -3 P -4 P -5 TYPE: 8' GYPSUM BOARD TYPE: 8" MOISTURE - RESISTANT GYPSUM BOARD TYPE: a" PLYWOOD TYPE: t MDO PLYWOOD COLOR: SAND (P505) BY: DALTILE SIZE: 6"xl 3" VERANDA COVE BASE TILE (P505- S36E9T1 P) LOCATION: SALES ROOM & HOT FOOD GROUT: #42 MOCHA ULTRA PRO GROUT 9999624412 (SUPPLIED BY MAPEI) (NOTE: CORNER BASE TILE "SAND" P505, PRODUCT #P505- SC36E9T1 P) ICI #A0090 - "CANDLE WAX" EGGSHELL FINISH ICI #A1807 - "WATER CHESTNUT' SEMI -GLOSS PANTONE PMS 422C - "DOVE GREY" ICI #A0409 - "RED BADGE" ICI #A0731 "DAKOTA LAND" NEW UNISEX RESTROOM PLAN SCALE: 1 /2" = 1' -0" CLIENT: ARCO BP WEST COAST PRODUCTS, LLC 014 A(1 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. A A A A 11 A DATE 05.26.09 06.05.09 06.23.09 06.23.09 CONFIDENTIALITY STATEMENT: REVISION DESCRIPTION PERMIT REVIEW - BP ISSUED FOR PERMIT - CITY SIGN PERMIT REVIEW - CITY RESPONSE TO COMMENTS SEAL: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALUANCE, AND ALSO, THAT WE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALUANCE, WHICHEVER COMES FIRST. CLIENT: bp r .A„. IF ARCO BP WEST COAST PRODUCTS, LLC O 1' U "k G A' �� k Q ENG0 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION A 05.26.09 PERMIT REVIEW - BP A 06.05.09 ISSUED FOR PERMIT - CITY / \ 06.23.09 SIGN PERMIT REVIEW - CITY 4 \ 06.23.09 RESPONSE TO COMMENTS A A A A A A SEAL: s'‘ \D 1.--. 10 NA o N% \ ��� 1 � A•S A I ♦; - 39913 CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, HAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO. GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @1 -5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: ALLIANCE Z&DM: CHECKED BY: BP REPM: DRAWN BY: ALLIANCE PM: VERSION: - PROJECT NO: 1975.75 DRAWING TITLE: FLOOR TILE PLAN SHEET NO: A VCT -1 NEW 111e1W., 111111 11MUMB ■e■■ a Imo' ; %rte__ L��;i �■�1 e ■■®■e ■e ■■NIM EMOUNII // // .14. %q ■ � ■ ■ I 1111111■■■■1■ee11elle 111■■1111EM M■rm ee i 111111111111111111111111111111111114111111111111.111111111111111111111uVEN 1111 ■I�� ■�S ■ e�■ NEW T -1 URUIUIUhUIUUIUIURRlIU I I 111111 LIIII IIIIIIIIIIIIIIIIIIIIMEIUIZill1111111111111111111M111111N11 ■ %r■� ®II %■■ % �� ■■ �■ ,e■11e ■�■■■��- -11® ■■■■■ ■■ ■®�11■ . 0 �� %� ■%% ■rAZII ■% �■ E�111 M � % ■■ % % %1111 %/■■ % %1111 % %MI■ % %1111 %% ■■ 4r Air A la% %■■% %� ■ % %tl ■■ A V Air A ■ % %1■■%%■ ■%%�1 _ n T -1 T -2 1111'AZ 1 na ���m��1 1■■e ■e �■■■e ®• ■� ■vAv�■v ■�i���. ll�. ■e■■■® I ■90,••� ■ ®■ 11111111111111111111111111 1■11 ®11fe1111■■1 ■® e■� 'saw ►\ ■ � 7 ®IJ■ ®iP�0/�11� ■■Ie1 ■■■eke i i ■■■■■—■■■■%j■■%j® ®i■■eeel. 1111 X 111 ME 1 1111■■ ■ 11S■ ■ % %��% % ®%% e■■ ■e .111� ■�■ ■e ■ ■l1M$R ■ ■ ■ ■sRUt - e■ —N■ �ee�®■.a��■e�n ®ee ■� i■ O���i i ■■ ■11._11■ ■■ ",� IHIHHIIIIIH _ ' ,/0 1111 0,9 T -1 T -2 ii i ® r rANIMEr. r _ ■e— ■111111 ■ ■� 11111111111Lai■I FAZ ;41111\1" 111111"/A111111/7/41 11 111111 MINI' %I %I/1% I . Al Few r r %%/ i / rA � i Amor 1 . III.IIIIIIII. ■■■■■RI ■�� ■■■■■111 1 MIN' 1 I _• 01 FLOOR TILE PLAN SCALE: 1/4" = 1' -0" 03 01 PEMCO 253A ALUMINUM A.D.A. TRANSITION STRIP THIN -SET CERAMIC TILE . dia•IAIoTRIA ∎7T•IA7•a•IA ➢MIA7:EIA CIAT 4V.. 0 '` a CONCRETE FLOOR SLAB .4 4 .. TILE TERMINATION DETAIL SCALE: 3" = 1' -0" 4'.•: o ° d , ..a x 2 5 6 7 x CON -1 DOOR PER SCHEDULE WEATHER STRIPPING BY G.C. II 11 11 1i eArAr mm∎ ALUMINUM THRESHOLD PEMKO OR EQ. BY G.C. EXTERIOR SIDEWALK X 02 4. o G q d a ENTRY DOOR DETAIL SCALE: 3" = 1' -0" REVIEWED FOR CODE COMPLIANCE APP ` OVI! JUL 17 2009 City of Tukwila BUILDING DIVISION FLOOR FINISH SEE SCHED. 0 -0" F.F. GENERAL NOTES: A. TRANSITIONS FROM ONE ROOM TO ANOTHER SHALL BE DONE UNDER CENTER OF DOORS WHERE POSSIBLE B. WALL BASE, REFER TO INTERIOR ELEVATIONS C. REPLACE FLOOR FINISH IN SALES AREA AND BACK ROOM. D. ALL FLOORS RECEIVING NEW TILE MUST BE SCRAPED AND LEVELED BEFORE FLOORING APPLICATION. ANY IRREGULARITIES VISIBLE IN FLOORING WILL HAVE TO BE REPLACED. E. PREFERRED FULL TILE FLOORING AT BOTTOM CENTER OF ENTRANCE DOOR. CONTACT GLOBAL ALLIANCE PROJECT MANAGER PRIOR TO TILE PLACEMENT. F. ALL FLOORS SHALL BE CLEANED AND SEALED PER MANUFACTURERS RECOMMENDATIONS. ALL FLOORS UNDER SALES SHELVING SHALL BE CLEANED PRIOR TO SHELF PLACEMENT. THE CONTRACTOR SHALL ARRANGE A SECOND CLEANING JUS PRIOR TO STORE OPENING. G. CONTINUOUS TILE BASE TYPICAL THROUGHOUT SALES AREA AT ALL WALLS AND CABINETS. H. INSTALLATION OF NEW FLOOR FINISH IN THE OFFICE IS AT OWNER'S DISCRETION. CONFIRM WITH OWNER PRIOR TO BID. K. EXISTING FLOORING TO REMAIN SHALL BE CLEANED FOLLOWING CONSTRUCTION. KEYED NOTES: O START FULL TILE FLOORING AT BOTTOM CENTER OF ENTRANCE DOORS THRESHOLD CENTER TILE PATTERN IN REST ROOMS FLOOR SINKS, NEW & EXISTING FLOOR DRAINS, SLOPE FLOOR AS SHOWN BY TILE INSTALLER EQUIPMENT FLOOR AREA, REFER TO Q.1.1 FOR EQUIPMENT INFORMATION 0 0 0 0 0 FLOOR FINISH CERAMIC TILE I T -1 I T -2I VCT -1 NEW PRODUCT: 12x12 MOUNTAIN PEAK (MP0112121P) COLOR: SAND (MP01) MANUF: DALTILE CONTACT: NATIONAL ACCOUNT ORDER DESK: (877) 556 -5728 GROUT: #42 MOCHA ULTRA PRO GROUT 9999624412 (SUPPLIED BY MAPEI) MORTAR: GRAY RAPID SETTING MORTAR 555550TM1350G (SUPPLIED BY MAPEI) PRODUCT: 12x12 MOUNTAIN PEAK (MPO412121P) COLOR: MOUNTAIN PEAK CLAY (MPO4) MANUF: DALTILE CONTACT: NATIONAL ACCOUNT ORDER DESK: (877) 556 -5728 GROUT: #42 MOCHA ULTRA PRO GROUT 9999624412 (SUPPLIED BY MAPEI) MORTAR: GRAY RAPID SETTING MORTAR 555550TM1350G (SUPPLIED BY MAPEI) "ARMSTRONG" VCT, 12 "X12 ", 1/8 -INCH THICK"; ARTEFFECTS; COLOR: PARCHMENT BEIGE #57200 REFERENCE SPEC: ASTM F 1066 CLASS 3 — SURFACE — PATTERN; FIRE TEST DATA: ASTM 3 648 CRITICAL RADIANT FLUX CLASS I — 0.45 0l MORE watts /cm2 and ASTM E 662 SMOKE DEVELOPED 450 or LESS STATIC LOAD LIMIT: ASTM F 970 125psi CONCRETE (TYPICAL ALL EXISTING) CON-11 WALL WHERE OCCURS %" WATER RESISTIVE OR STANDARD GYP. BOARD WHERE APPLICABLE %" CEMENT BACKER BOARD BEHIND BASE, TYP. TILE COVE BASE 3/8" RADIUS FLOOR TILE PATCHING (AS REQUIRED) OF EXISTING CONCRETE SHALL BE REPAIRED WITH FEATHER PATCH, BY EDOCO BURKE SMOOTH MACHINE TROWEL FINISH. COATING: BURKE SPARTAN COTE WB11 30% BURKE BY EDOCO 22029 SOUTH WESTWARD AVE. LONG BEACH, CA 90810 //// %////2 //40 /I • 0 TILE BASE DETAIL SCALE: 3" = 1' -0" RECEIVED CITY OF TUKWLA JUL Q8 2009 PERMIT CENTER %% rA 1 EXIS" OFFI MII NUM MEM MIN NNE ii i MONITOR NEW COFFEE GRAPHIC ON EXISTING SOFFIT "chilled" HIC --- 1 T t+1fl IIUI(U1l1iit'rIC ,IIJIICii'?J 11111a ISTING ECUR AMEBAS ("_ "T _ " T° 1 1 J NMI MEM MUM ENE € . ,r,7 1 . 1 1 '1 L 1 1 -1 1 MOM MEE HIM 211 MINN MINN i EXIST ® ®u1 L!! '14 no1i I`�1....1 iii t `1 1 .. o :I G k L L I E I j I . .I 1 I' 3 I 1 T 1 l C f . T . T1 .; rT I. T_`1 T J : 1 L J oero 1 L J ® _' I t 411111111111 ®® I�1111111111111111111 \ I I CT-1 II, \1 I I EXISTING ACOUSTIC, NO CHANGES EXISTING THRU —WALL VENT GRILL EXISTING WALL MOUNT METAL HALIDE LIGHT TO REMAIN 10 " -18" PREFERRED DISTANCE FROM GRAPHIC PANEL FOR OPTIMAL LIGHT DISPERSION. CONTACT P.M. FOR SITE SPECIFIC CHANGES AND APPLICATION. EXISTING THRU —WALL VENT GRILL EDGE OF EXISTING METAL CEILING TO NEW GYP. BD. CEILING NEW SURFACE MTD. 2X4 PARABOLIC CUBE LIGHT FIXTURE, MATCH EXIST. RELOCATED "Thirst Oasis" INTERNALLY ILLUMINATED SIGN PROVIDE EXHAUST FAN IN THIS AREA NON— ILLUMINATED GRAPHIC w /FRAME BY LSI SURFACE MOUNT NEW WALL WASH LIGHTS IN THIS AREA ONLY INSTALL (1) NEW SECURITY CAMERA 10 " -18" PREFERRED DISTANCE FROM GRAPHIC PANEL FOR OPTIMAL LIGHT DISPERSION. CONTACT P.M. FOR SITE SPECIFIC CHANGES AND APPLICATION. EXISTING 2" OVERHEAD ELEd,T. POWER CONDUIT, ATTACHED TO WALL® 8' ABV. FIN. FIR. TO REMAIN EXISTING WALL MOUNT METAL HALIDE LIGHT TO REMAIN SCALE: 1 /4" = 1' -0" XISTING COVERED S55`NCLOSURE, EXISTING STORAGE REMOVE EXHAUST FAN IN THIS AREA — PROVIDE FLUSH COVER PLATE IN EXIST. METAL CEILING EXISTING 400w METAL HALIDE CANOPY LIGHT FIXTURES, 10 TYPICAL EXISTING WALL MOUNT METAL HALIDE FLOODLIGHTS TO REMAIN EXISTING SECURITY CAMERA EXISTING STORAGE CONTAINER I QUANTITY TYPE WATTS TOTAL WATTS 3 2x4 — 3 LAMP T -12 W/ ELECT. 108 324 BALLAST FLUORESCENT STRIP LIGHTS— 1 LAMP 6 T -12 W/ ELECT. BALLAST 32 192 5 INCANDESCENT TRACK LIGHTING 60 300 2 2x4 — 2 LAMP T -12 W/ 72 144 ELEC. BALLAST 0 - 0 0 — 0 0 TOTAL WATTS 960 QUANTITY TYPE WATTS TOTAL WATTS 2x4 3 LAMP T -12 W/ MAG. 1 BALLAST (SURFACE MID.) 108 108 1x4 — 1 LAMP T -12 W/ MAG. 1 BALLAST (SURFACE MID.) 42 42 1x4 1 LAMP T -8 W/ 12 ELEC. BALLAST (2 SURFACE MID.) 29 348 1x2 — 1 BIAX LAMP W/ 2 ELEC. BALLAST (1 SURACE MID.) 22 44 COMPACT FLUORESCENT TRACK 5 LIGHTING - (2) CFL RS LAMPS 36 /PAIR 180 0 0 0 TOTAL WATTS 722 ICISO SOFFIT P -2 REPLACE SHELF TYPE MONITOR w/ NEW 15" CCTV PER SECURELY NOTES BELOW INSTALL NEW 13" HIGH INTERNALLY ILLUMINATED 'ampm' SIGN (UNDER SEPARATE PERMIT) EXISTING CANOPY, SEE SITE PLAN REMOVE 'ampm' SIGN EXISTING SECURITY CAMERA EXISTING FLUORESCENT EAVE LIGHTING TO REMAIN EXISTING MECHANICAL UNITS TO REMAIN w /IN SCREENED ENCLOSURE EXISTING PREFAB COOLER SECURITY CHECKLIST: (SOME ITEMS MAY BE NOTED ON Q1.1/Q2.1) Safety and Security /Video Surveillance System Optional Video Equipment • Additional video cameras (interior and exterior). • 13" color monitor should be ceiling mounted near cash register area. Monitor must sequence the exterior camera images and must be readily viewed by cashier. • Interactive Audio /Video Monitoring service provided by approved vendor for 24 -hour interactive off - facility security monitoring service. — EXISTING OVERFILL ALARM & SECURITY CAMERA Required Equipment • 20" color public view monitor should be ceiling mounted at the entrance of store. As the customer enters the facility, the image should be readily seen. • A minimum of 15 "color monitor should be placed in the back office for viewing and monitoring. • Where back office space is limited, a smaller color monitor may be appropriate. • Robot /Sensormatic color (16 port) multiplexer. • Approved time lapse video recorder (best results are obtained in 24 -hour recording mode). O 24 -hour real time audio recording (recorded on 24 -hour video tape). 0 • Approved secure cabinet for recording equipment. • A minimum of five -color video cameras with proper lenses mounted in- store. (4 EXISTING, INSTALL 1 NEW). • A minimum of two exterior mounted cameras with environmental housings to cover operations at the fueling islands. (2 EXTERIOR (1 IS EXISTING)) • Facilities with cash accepting PIC units must have camera coverage for each operable side of the unit. If a single camera cannot view both sides of a dual unit, then additional cameras must be installed to complete coverage. (2 NEW CAMERAS FOR PIC COVERAGE WILL BE REQUIRED) Optional Digital Recorder Requirements • Digital CCTV recording system: Sufficient hard drive space to support 12 color cameras at 5V2 frames per second, per camera, for 31 days. • Audio Recording is required at the Sales Counter Area. . An Audio Processing Kit (Louroe preferred) is required to synchronize the Audio with the Video image. PERFORMANCE REQUIREMENTS: THE MAIN RUNNERS AND CROSS RUNNERS OF THE CEILING SYSTEM AND THEIR SPLICES, INTERSECTION CONNECTORS AND EXPANSION DEVICES SHALL BE DESIGNED AND CON— STRUCTED TO CARRY A MEAN ULTIMATE TEST LOAD OF NOT LESS THAN 180 POUNDS (801 N) OR TWICE THE ACTUAL LOAD, WHICHEVER IS GREATER, IN TENSION WITH 5— DEGREE MISALIGNMENT OF THE MEMBERS IN ANY DIRECTION, AND IN COMPRESSION. IN LIEU OF 5— DEGREE MISALIGNMENT, THE LOAD MAY BE APPLIED WITH A 1 —INCH (25.4MM) ECCENTRICITY ON A SAMPLE NOT MORE THA 24 INCHES (610 MM) LONG ON EACH SIDE OF THE SPLICE. THE CONNECTIONS AT SPLICES AND INTERSECTIONS SHALL ALL BE OF THE MECHANICAL INTERLOCKING TYPE. A.1.3 SUSPENDED CEILING DETAIL AT WALL 45'MAX. 45' MAX LAY -IN CEILING SUSPENSION SYSTEM SUSPENDED CEILING NOTES: 1. NEW OR ALTERED SUSPENDED CEILING SYSTEM MUST BE HEAVY DUTY SYSTEM CONFORMING TO ASTM C 635 AND C 636. IBC 803.9.1.1 (SDC 'D' OR 'E') 2. SUSPENDED MEMBER GRID MUST BE ATTACHED TO TWO ADJACENT WALLS ON MINIMUM 2" WIDE WALL MOLDINGS OR CLOSURE ANGLES AT THESE WALLS. 3. ENDS OF SUSPENDED MEMBER MAIN RUNNERS AND CROSS RUNNERS MUST BE TIED TOGETHER TO PREVENT DISLOCATION. 4. LIGHT FIXTURES 10Ibs. TO 55Ibs. IN WEIGHT MUST BE SUPPORTED TO STRUCTURE BY AT LEAST TWO #12 GAGE HANGER WIRES, EACH AT TWO OPPOSING SIDES, AND SHALL BE ATTACHED TO SUSPENDED MEMBER GRID AT TWO OPPOSING SIDES. WIRES MAY BE SLACK. 5. HVAC TERMINALS OR REGISTERS 20Ibs. TO 561bs. IN WEIGHT SHALL BE POSITIVELY ATTACHED TO SUSPENDED MEMBER MAIN RUNNERS, OR TO CROSS RUNNERS WITH EQUAL CARRYING CAPACITY , AND MUST ALSO BE SUPPORTED TO STRUCTURE BY AT LEAST TWO #12 GAGE HANGER WIRES AT TWO OPPOSING SIDES. WIRES MAY BE SLACK. ® rillallit1 PROVIDE (2) — -:�'- \ II KICKERS (BOTH \ PARALLEL TO AN PERPENDICULAR T SECURE ANGLES TO \ TRUSS SPAN) \ ROOF STRUCTURE WITH A i — SELF TAPPING SCREWS 1 1 A.1.3 NOT TO EXCEED 6' -0" - -SPLAY BRACE WIRE 8" (MAX.) OR 1/4 LENGTH - OF DIST. TO FIRST MAIN, #12 GAGE MIN. MAIN RUNNER CROSS TEE SCALE: 3/4" = 1 ' -0 SECURE SUPPORT WIRES TO EXISTING STRUCTURE 1/2" EMT - RUN TIGHT TO STRUCTURE ABOVE (4' -0" MAX. FOR 1/2" DIA.) 12 GA. VERTICAL HANGER WIRE COMPRESSION STRUT REQUIRED AT EACH SEISMIC RESTRAINT 12' -0" 0.C. EACH WAY AND WITHIN 6' -0" OF EACH WALL VERTICAL — 12 GA. HANGER WIRE AT 4' —O" 0.C 3/4" EMT — NOTCH OVER MAIN RUNNER DRILL 5/32" HOLE FOR 1/8" BOLT AND LOCK— NUT AFTER CEILING SYSTEM IS LEVELED (4) -12 GA. SPLAY WIRES SPLAYED 90' FROM EACH AND 45° FROM CEILING P WALL TRIM 45* MAX. -- -- -(3) TURNS MIN. IN 1 1 /2 "(TYPICAL ,/ 45' MAX. I . CONT. HORIZ. STRUT TO PREVENT SPREADING OF RUNNERS; 12' 0.C. MAX. 1 `MOUNTING STRUT AND \ I CEILING GROMMET BY \ SECURITY CONTRACTOR \ - i (2) L 5x3" 7 GA. MIN. MOUNTING ANGLES WITH 1/2" BOLTS AND WASHERS ON EACH SIDE TYP. OF (4) SPACING WASHERS BETWEEN ANGLES 3/8" BOLTS FURNISHED WITH ADAPTERS L 1 "x1 "x12 GAGE SPLIT PIPE CLAMP ERICO OR APPROVED - MOUNTING STRUT AND CEILING GROMMET BY SECURITY CONTRACTOR REVIEWED POF CODE COMPLIANT APP,- OVED OTHER JUL 1 7 2009 ( ANE City of Tukwila IVISIpi GENERAL NOTES: A. ALL DIMENSIONS SHOWN ON REFLECTED CEILING PLAN ARE FROM FACE OF WALL FINISH UNLESS NOTED OTHERWISE B. POINT LIGHTS FOR INTERIOR SIGNAGE ARE TO HAVE THE WIRING RAN, BUT LIGHTS SHALL NOT BE INSTALLED UNTIL SIGNAGE HAS BEEN HUNG. C. ALL BACKROOM CEILING TILES ARE TO BE REPLACED PER HEALTH DEPARTMENT REQUIREMENTS. D. FLAME SPREAD CLASSIFICATIONS FOR INTERIOR CEILING FINISHES SHALL COMPLY WITH 2006 IBC TABLE 803.5. KEYED NOTES: O INSTALL NEW EXIT SIGN WITH BATTERY BACK UP LIGHTS O NEW OVEN HOOD. REFER TO MECHANICAL SHEETS. O SURFACE MOUNT LIGHT FIXTURES IN THIS AREA. ® EXISTING COOLER /FREEZER LIGHTS TO REMAIN (NOT SHOWN) CEILING FINISH: TYPE: ROCKFON "KORAL" 4'x2'x5/8" (WHITE) SUSPENDED ACOUSTICAL CEILING TILE. FLAME SPREAD CLASS 0 IN I CT -1 I ACCORDANCE WITH BLDG REGULATIONS. CLASS 1 SURFACE SPREAD OF FLAME IN ACCORDANCE WITH BS 476 PART 7. TYPE: USG #3270 "CLIMAPLUS VINYL" 24 "x48 "xY" (WHITE) WASHABLE SUSPENDED CEILING TILE (OR APPROVED EQUAL). CT -2 I FLAME SPREAD 25, CLASS A; SMOKE DEVELOPED: 50; ASTM E84. GRID: CHICAGO METALLIC GRID — EXPOSED GRID SYSTEM (FLAT WHITE) TYPE: i" GYPSUM WALLBOARD, SMOOTH FINISH (MTL FRAMING 2.5" STUDS © 16" O.C.) TYPE: EXISTING STANDING SEAM SHEET METAL CEILING SYMBOL UST I LAY —IN FLUORESCENT (SEE ELECTRICAL FOR SPEC.) (R) (M) — MOVE LIGHTING /FIXTURE \ (R) — RELOCATED LIGHTING /FIXTURE (N) f—(N) — NEW LIGHTING () — (D) — LIGHTING TO BE DEMO'D NO LETTER — EXISTING TO REMAIN NEW CEILING TILES (TYPE AS SPECIFIED) NEW GRID AS REQUIRED v q EGRESS FIXTURES �� II i �G I I ' 33 SUPPLY AIR DIFFUSER TO BE MOVED 0 1111-5 IIII SUPPLY AIR DIFFUSER I O -- - ? (M) RETURN AIR GRILLE TO BE MOVED ( (R) RETURN AIR GRILLE TO BE RELOCATED r : EXHAUST OR RELIEF AIR VENT 108' — CEILING ELEVATION GB CEILING MATERIAL P -2 CEILING FINISH EM EMERGENCY FIXTURES, REFER TO ELECTRICAL LIGHTING PLAN FOR MORE INFORMATION 1= SECURITY CAMERA (APPROXIMATE LOCATION) "PRESCOLITE" AKTHLCE218 FLUORESCENT 4$'' ' '"� ► TRACK LIGHTING USE TWO (2) 18W HIGH LUMEN CFL RS LAMPS 1 I CCTV MONITORS INTERIOR PAINTS: ICI #A0090 — "CANDLE WAX" EGGSHELL FINISH ICI #A1807 — "WATER CHESTNUT" SEMI —GLOSS ICI #A0717 — "INDIAN CORN" ICI #A0409 — "RED BADGE" COLOR: BP HIGH HIDING WHITE ICI BP HIGH HIDING WHITE (CUSTOM) I WHITE EXTERIOR PAINTS: REFER TO EXTERIOR ELEVATIONS FOR FINISH SPECIFICATIONS I WHITE RECEIVED CITY OF TUKWILA JUL U 8 •/IIIIy PERMIT CENTER CLIENT: AkIk O ARCO BP WEST COAST PRODUCTS, LLC 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES 05.26.09 06.05.09 06.23.09 REVISION DESCRIPTION PERMIT REVIEW — BP ISSUED FOR PERMIT — CITY SIGN PERMIT REVIEW — CITY SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: AWANCE Z &DM: BP REPM: AWANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: REFLECTED CEILING PLAN SHEET NO: • :2)0:::: LIGHTING ADDED 1 EXIS" OFFI MII NUM MEM MIN NNE ii i MONITOR NEW COFFEE GRAPHIC ON EXISTING SOFFIT "chilled" HIC --- 1 T t+1fl IIUI(U1l1iit'rIC ,IIJIICii'?J 11111a ISTING ECUR AMEBAS ("_ "T _ " T° 1 1 J NMI MEM MUM ENE € . ,r,7 1 . 1 1 '1 L 1 1 -1 1 MOM MEE HIM 211 MINN MINN i EXIST ® ®u1 L!! '14 no1i I`�1....1 iii t `1 1 .. o :I G k L L I E I j I . .I 1 I' 3 I 1 T 1 l C f . T . T1 .; rT I. T_`1 T J : 1 L J oero 1 L J ® _' I t 411111111111 ®® I�1111111111111111111 \ I I CT-1 II, \1 I I EXISTING ACOUSTIC, NO CHANGES EXISTING THRU —WALL VENT GRILL EXISTING WALL MOUNT METAL HALIDE LIGHT TO REMAIN 10 " -18" PREFERRED DISTANCE FROM GRAPHIC PANEL FOR OPTIMAL LIGHT DISPERSION. CONTACT P.M. FOR SITE SPECIFIC CHANGES AND APPLICATION. EXISTING THRU —WALL VENT GRILL EDGE OF EXISTING METAL CEILING TO NEW GYP. BD. CEILING NEW SURFACE MTD. 2X4 PARABOLIC CUBE LIGHT FIXTURE, MATCH EXIST. RELOCATED "Thirst Oasis" INTERNALLY ILLUMINATED SIGN PROVIDE EXHAUST FAN IN THIS AREA NON— ILLUMINATED GRAPHIC w /FRAME BY LSI SURFACE MOUNT NEW WALL WASH LIGHTS IN THIS AREA ONLY INSTALL (1) NEW SECURITY CAMERA 10 " -18" PREFERRED DISTANCE FROM GRAPHIC PANEL FOR OPTIMAL LIGHT DISPERSION. CONTACT P.M. FOR SITE SPECIFIC CHANGES AND APPLICATION. EXISTING 2" OVERHEAD ELEd,T. POWER CONDUIT, ATTACHED TO WALL® 8' ABV. FIN. FIR. TO REMAIN EXISTING WALL MOUNT METAL HALIDE LIGHT TO REMAIN SCALE: 1 /4" = 1' -0" XISTING COVERED S55`NCLOSURE, EXISTING STORAGE REMOVE EXHAUST FAN IN THIS AREA — PROVIDE FLUSH COVER PLATE IN EXIST. METAL CEILING EXISTING 400w METAL HALIDE CANOPY LIGHT FIXTURES, 10 TYPICAL EXISTING WALL MOUNT METAL HALIDE FLOODLIGHTS TO REMAIN EXISTING SECURITY CAMERA EXISTING STORAGE CONTAINER I QUANTITY TYPE WATTS TOTAL WATTS 3 2x4 — 3 LAMP T -12 W/ ELECT. 108 324 BALLAST FLUORESCENT STRIP LIGHTS— 1 LAMP 6 T -12 W/ ELECT. BALLAST 32 192 5 INCANDESCENT TRACK LIGHTING 60 300 2 2x4 — 2 LAMP T -12 W/ 72 144 ELEC. BALLAST 0 - 0 0 — 0 0 TOTAL WATTS 960 QUANTITY TYPE WATTS TOTAL WATTS 2x4 3 LAMP T -12 W/ MAG. 1 BALLAST (SURFACE MID.) 108 108 1x4 — 1 LAMP T -12 W/ MAG. 1 BALLAST (SURFACE MID.) 42 42 1x4 1 LAMP T -8 W/ 12 ELEC. BALLAST (2 SURFACE MID.) 29 348 1x2 — 1 BIAX LAMP W/ 2 ELEC. BALLAST (1 SURACE MID.) 22 44 COMPACT FLUORESCENT TRACK 5 LIGHTING - (2) CFL RS LAMPS 36 /PAIR 180 0 0 0 TOTAL WATTS 722 ICISO SOFFIT P -2 REPLACE SHELF TYPE MONITOR w/ NEW 15" CCTV PER SECURELY NOTES BELOW INSTALL NEW 13" HIGH INTERNALLY ILLUMINATED 'ampm' SIGN (UNDER SEPARATE PERMIT) EXISTING CANOPY, SEE SITE PLAN REMOVE 'ampm' SIGN EXISTING SECURITY CAMERA EXISTING FLUORESCENT EAVE LIGHTING TO REMAIN EXISTING MECHANICAL UNITS TO REMAIN w /IN SCREENED ENCLOSURE EXISTING PREFAB COOLER SECURITY CHECKLIST: (SOME ITEMS MAY BE NOTED ON Q1.1/Q2.1) Safety and Security /Video Surveillance System Optional Video Equipment • Additional video cameras (interior and exterior). • 13" color monitor should be ceiling mounted near cash register area. Monitor must sequence the exterior camera images and must be readily viewed by cashier. • Interactive Audio /Video Monitoring service provided by approved vendor for 24 -hour interactive off - facility security monitoring service. — EXISTING OVERFILL ALARM & SECURITY CAMERA Required Equipment • 20" color public view monitor should be ceiling mounted at the entrance of store. As the customer enters the facility, the image should be readily seen. • A minimum of 15 "color monitor should be placed in the back office for viewing and monitoring. • Where back office space is limited, a smaller color monitor may be appropriate. • Robot /Sensormatic color (16 port) multiplexer. • Approved time lapse video recorder (best results are obtained in 24 -hour recording mode). O 24 -hour real time audio recording (recorded on 24 -hour video tape). 0 • Approved secure cabinet for recording equipment. • A minimum of five -color video cameras with proper lenses mounted in- store. (4 EXISTING, INSTALL 1 NEW). • A minimum of two exterior mounted cameras with environmental housings to cover operations at the fueling islands. (2 EXTERIOR (1 IS EXISTING)) • Facilities with cash accepting PIC units must have camera coverage for each operable side of the unit. If a single camera cannot view both sides of a dual unit, then additional cameras must be installed to complete coverage. (2 NEW CAMERAS FOR PIC COVERAGE WILL BE REQUIRED) Optional Digital Recorder Requirements • Digital CCTV recording system: Sufficient hard drive space to support 12 color cameras at 5V2 frames per second, per camera, for 31 days. • Audio Recording is required at the Sales Counter Area. . An Audio Processing Kit (Louroe preferred) is required to synchronize the Audio with the Video image. PERFORMANCE REQUIREMENTS: THE MAIN RUNNERS AND CROSS RUNNERS OF THE CEILING SYSTEM AND THEIR SPLICES, INTERSECTION CONNECTORS AND EXPANSION DEVICES SHALL BE DESIGNED AND CON— STRUCTED TO CARRY A MEAN ULTIMATE TEST LOAD OF NOT LESS THAN 180 POUNDS (801 N) OR TWICE THE ACTUAL LOAD, WHICHEVER IS GREATER, IN TENSION WITH 5— DEGREE MISALIGNMENT OF THE MEMBERS IN ANY DIRECTION, AND IN COMPRESSION. IN LIEU OF 5— DEGREE MISALIGNMENT, THE LOAD MAY BE APPLIED WITH A 1 —INCH (25.4MM) ECCENTRICITY ON A SAMPLE NOT MORE THA 24 INCHES (610 MM) LONG ON EACH SIDE OF THE SPLICE. THE CONNECTIONS AT SPLICES AND INTERSECTIONS SHALL ALL BE OF THE MECHANICAL INTERLOCKING TYPE. A.1.3 SUSPENDED CEILING DETAIL AT WALL 45'MAX. 45' MAX LAY -IN CEILING SUSPENSION SYSTEM SUSPENDED CEILING NOTES: 1. NEW OR ALTERED SUSPENDED CEILING SYSTEM MUST BE HEAVY DUTY SYSTEM CONFORMING TO ASTM C 635 AND C 636. IBC 803.9.1.1 (SDC 'D' OR 'E') 2. SUSPENDED MEMBER GRID MUST BE ATTACHED TO TWO ADJACENT WALLS ON MINIMUM 2" WIDE WALL MOLDINGS OR CLOSURE ANGLES AT THESE WALLS. 3. ENDS OF SUSPENDED MEMBER MAIN RUNNERS AND CROSS RUNNERS MUST BE TIED TOGETHER TO PREVENT DISLOCATION. 4. LIGHT FIXTURES 10Ibs. TO 55Ibs. IN WEIGHT MUST BE SUPPORTED TO STRUCTURE BY AT LEAST TWO #12 GAGE HANGER WIRES, EACH AT TWO OPPOSING SIDES, AND SHALL BE ATTACHED TO SUSPENDED MEMBER GRID AT TWO OPPOSING SIDES. WIRES MAY BE SLACK. 5. HVAC TERMINALS OR REGISTERS 20Ibs. TO 561bs. IN WEIGHT SHALL BE POSITIVELY ATTACHED TO SUSPENDED MEMBER MAIN RUNNERS, OR TO CROSS RUNNERS WITH EQUAL CARRYING CAPACITY , AND MUST ALSO BE SUPPORTED TO STRUCTURE BY AT LEAST TWO #12 GAGE HANGER WIRES AT TWO OPPOSING SIDES. WIRES MAY BE SLACK. ® rillallit1 PROVIDE (2) — -:�'- \ II KICKERS (BOTH \ PARALLEL TO AN PERPENDICULAR T SECURE ANGLES TO \ TRUSS SPAN) \ ROOF STRUCTURE WITH A i — SELF TAPPING SCREWS 1 1 A.1.3 NOT TO EXCEED 6' -0" - -SPLAY BRACE WIRE 8" (MAX.) OR 1/4 LENGTH - OF DIST. TO FIRST MAIN, #12 GAGE MIN. MAIN RUNNER CROSS TEE SCALE: 3/4" = 1 ' -0 SECURE SUPPORT WIRES TO EXISTING STRUCTURE 1/2" EMT - RUN TIGHT TO STRUCTURE ABOVE (4' -0" MAX. FOR 1/2" DIA.) 12 GA. VERTICAL HANGER WIRE COMPRESSION STRUT REQUIRED AT EACH SEISMIC RESTRAINT 12' -0" 0.C. EACH WAY AND WITHIN 6' -0" OF EACH WALL VERTICAL — 12 GA. HANGER WIRE AT 4' —O" 0.C 3/4" EMT — NOTCH OVER MAIN RUNNER DRILL 5/32" HOLE FOR 1/8" BOLT AND LOCK— NUT AFTER CEILING SYSTEM IS LEVELED (4) -12 GA. SPLAY WIRES SPLAYED 90' FROM EACH AND 45° FROM CEILING P WALL TRIM 45* MAX. -- -- -(3) TURNS MIN. IN 1 1 /2 "(TYPICAL ,/ 45' MAX. I . CONT. HORIZ. STRUT TO PREVENT SPREADING OF RUNNERS; 12' 0.C. MAX. 1 `MOUNTING STRUT AND \ I CEILING GROMMET BY \ SECURITY CONTRACTOR \ - i (2) L 5x3" 7 GA. MIN. MOUNTING ANGLES WITH 1/2" BOLTS AND WASHERS ON EACH SIDE TYP. OF (4) SPACING WASHERS BETWEEN ANGLES 3/8" BOLTS FURNISHED WITH ADAPTERS L 1 "x1 "x12 GAGE SPLIT PIPE CLAMP ERICO OR APPROVED - MOUNTING STRUT AND CEILING GROMMET BY SECURITY CONTRACTOR REVIEWED POF CODE COMPLIANT APP,- OVED OTHER JUL 1 7 2009 ( ANE City of Tukwila IVISIpi GENERAL NOTES: A. ALL DIMENSIONS SHOWN ON REFLECTED CEILING PLAN ARE FROM FACE OF WALL FINISH UNLESS NOTED OTHERWISE B. POINT LIGHTS FOR INTERIOR SIGNAGE ARE TO HAVE THE WIRING RAN, BUT LIGHTS SHALL NOT BE INSTALLED UNTIL SIGNAGE HAS BEEN HUNG. C. ALL BACKROOM CEILING TILES ARE TO BE REPLACED PER HEALTH DEPARTMENT REQUIREMENTS. D. FLAME SPREAD CLASSIFICATIONS FOR INTERIOR CEILING FINISHES SHALL COMPLY WITH 2006 IBC TABLE 803.5. KEYED NOTES: O INSTALL NEW EXIT SIGN WITH BATTERY BACK UP LIGHTS O NEW OVEN HOOD. REFER TO MECHANICAL SHEETS. O SURFACE MOUNT LIGHT FIXTURES IN THIS AREA. ® EXISTING COOLER /FREEZER LIGHTS TO REMAIN (NOT SHOWN) CEILING FINISH: TYPE: ROCKFON "KORAL" 4'x2'x5/8" (WHITE) SUSPENDED ACOUSTICAL CEILING TILE. FLAME SPREAD CLASS 0 IN I CT -1 I ACCORDANCE WITH BLDG REGULATIONS. CLASS 1 SURFACE SPREAD OF FLAME IN ACCORDANCE WITH BS 476 PART 7. TYPE: USG #3270 "CLIMAPLUS VINYL" 24 "x48 "xY" (WHITE) WASHABLE SUSPENDED CEILING TILE (OR APPROVED EQUAL). CT -2 I FLAME SPREAD 25, CLASS A; SMOKE DEVELOPED: 50; ASTM E84. GRID: CHICAGO METALLIC GRID — EXPOSED GRID SYSTEM (FLAT WHITE) TYPE: i" GYPSUM WALLBOARD, SMOOTH FINISH (MTL FRAMING 2.5" STUDS © 16" O.C.) TYPE: EXISTING STANDING SEAM SHEET METAL CEILING SYMBOL UST I LAY —IN FLUORESCENT (SEE ELECTRICAL FOR SPEC.) (R) (M) — MOVE LIGHTING /FIXTURE \ (R) — RELOCATED LIGHTING /FIXTURE (N) f—(N) — NEW LIGHTING () — (D) — LIGHTING TO BE DEMO'D NO LETTER — EXISTING TO REMAIN NEW CEILING TILES (TYPE AS SPECIFIED) NEW GRID AS REQUIRED v q EGRESS FIXTURES �� II i �G I I ' 33 SUPPLY AIR DIFFUSER TO BE MOVED 0 1111-5 IIII SUPPLY AIR DIFFUSER I O -- - ? (M) RETURN AIR GRILLE TO BE MOVED ( (R) RETURN AIR GRILLE TO BE RELOCATED r : EXHAUST OR RELIEF AIR VENT 108' — CEILING ELEVATION GB CEILING MATERIAL P -2 CEILING FINISH EM EMERGENCY FIXTURES, REFER TO ELECTRICAL LIGHTING PLAN FOR MORE INFORMATION 1= SECURITY CAMERA (APPROXIMATE LOCATION) "PRESCOLITE" AKTHLCE218 FLUORESCENT 4$'' ' '"� ► TRACK LIGHTING USE TWO (2) 18W HIGH LUMEN CFL RS LAMPS 1 I CCTV MONITORS INTERIOR PAINTS: ICI #A0090 — "CANDLE WAX" EGGSHELL FINISH ICI #A1807 — "WATER CHESTNUT" SEMI —GLOSS ICI #A0717 — "INDIAN CORN" ICI #A0409 — "RED BADGE" COLOR: BP HIGH HIDING WHITE ICI BP HIGH HIDING WHITE (CUSTOM) I WHITE EXTERIOR PAINTS: REFER TO EXTERIOR ELEVATIONS FOR FINISH SPECIFICATIONS I WHITE RECEIVED CITY OF TUKWILA JUL U 8 •/IIIIy PERMIT CENTER CLIENT: AkIk O ARCO BP WEST COAST PRODUCTS, LLC 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES 05.26.09 06.05.09 06.23.09 REVISION DESCRIPTION PERMIT REVIEW — BP ISSUED FOR PERMIT — CITY SIGN PERMIT REVIEW — CITY SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: AWANCE Z &DM: BP REPM: AWANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: REFLECTED CEILING PLAN SHEET NO: • :2)0:::: 1 EXIS" OFFI MII NUM MEM MIN NNE ii i MONITOR NEW COFFEE GRAPHIC ON EXISTING SOFFIT "chilled" HIC --- 1 T t+1fl IIUI(U1l1iit'rIC ,IIJIICii'?J 11111a ISTING ECUR AMEBAS ("_ "T _ " T° 1 1 J NMI MEM MUM ENE € . ,r,7 1 . 1 1 '1 L 1 1 -1 1 MOM MEE HIM 211 MINN MINN i EXIST ® ®u1 L!! '14 no1i I`�1....1 iii t `1 1 .. o :I G k L L I E I j I . .I 1 I' 3 I 1 T 1 l C f . T . T1 .; rT I. T_`1 T J : 1 L J oero 1 L J ® _' I t 411111111111 ®® I�1111111111111111111 \ I I CT-1 II, \1 I I EXISTING ACOUSTIC, NO CHANGES EXISTING THRU —WALL VENT GRILL EXISTING WALL MOUNT METAL HALIDE LIGHT TO REMAIN 10 " -18" PREFERRED DISTANCE FROM GRAPHIC PANEL FOR OPTIMAL LIGHT DISPERSION. CONTACT P.M. FOR SITE SPECIFIC CHANGES AND APPLICATION. EXISTING THRU —WALL VENT GRILL EDGE OF EXISTING METAL CEILING TO NEW GYP. BD. CEILING NEW SURFACE MTD. 2X4 PARABOLIC CUBE LIGHT FIXTURE, MATCH EXIST. RELOCATED "Thirst Oasis" INTERNALLY ILLUMINATED SIGN PROVIDE EXHAUST FAN IN THIS AREA NON— ILLUMINATED GRAPHIC w /FRAME BY LSI SURFACE MOUNT NEW WALL WASH LIGHTS IN THIS AREA ONLY INSTALL (1) NEW SECURITY CAMERA 10 " -18" PREFERRED DISTANCE FROM GRAPHIC PANEL FOR OPTIMAL LIGHT DISPERSION. CONTACT P.M. FOR SITE SPECIFIC CHANGES AND APPLICATION. EXISTING 2" OVERHEAD ELEd,T. POWER CONDUIT, ATTACHED TO WALL® 8' ABV. FIN. FIR. TO REMAIN EXISTING WALL MOUNT METAL HALIDE LIGHT TO REMAIN SCALE: 1 /4" = 1' -0" XISTING COVERED S55`NCLOSURE, EXISTING STORAGE REMOVE EXHAUST FAN IN THIS AREA — PROVIDE FLUSH COVER PLATE IN EXIST. METAL CEILING EXISTING 400w METAL HALIDE CANOPY LIGHT FIXTURES, 10 TYPICAL EXISTING WALL MOUNT METAL HALIDE FLOODLIGHTS TO REMAIN EXISTING SECURITY CAMERA EXISTING STORAGE CONTAINER I QUANTITY TYPE WATTS TOTAL WATTS 3 2x4 — 3 LAMP T -12 W/ ELECT. 108 324 BALLAST FLUORESCENT STRIP LIGHTS— 1 LAMP 6 T -12 W/ ELECT. BALLAST 32 192 5 INCANDESCENT TRACK LIGHTING 60 300 2 2x4 — 2 LAMP T -12 W/ 72 144 ELEC. BALLAST 0 - 0 0 — 0 0 TOTAL WATTS 960 QUANTITY TYPE WATTS TOTAL WATTS 2x4 3 LAMP T -12 W/ MAG. 1 BALLAST (SURFACE MID.) 108 108 1x4 — 1 LAMP T -12 W/ MAG. 1 BALLAST (SURFACE MID.) 42 42 1x4 1 LAMP T -8 W/ 12 ELEC. BALLAST (2 SURFACE MID.) 29 348 1x2 — 1 BIAX LAMP W/ 2 ELEC. BALLAST (1 SURACE MID.) 22 44 COMPACT FLUORESCENT TRACK 5 LIGHTING - (2) CFL RS LAMPS 36 /PAIR 180 0 0 0 TOTAL WATTS 722 ICISO SOFFIT P -2 REPLACE SHELF TYPE MONITOR w/ NEW 15" CCTV PER SECURELY NOTES BELOW INSTALL NEW 13" HIGH INTERNALLY ILLUMINATED 'ampm' SIGN (UNDER SEPARATE PERMIT) EXISTING CANOPY, SEE SITE PLAN REMOVE 'ampm' SIGN EXISTING SECURITY CAMERA EXISTING FLUORESCENT EAVE LIGHTING TO REMAIN EXISTING MECHANICAL UNITS TO REMAIN w /IN SCREENED ENCLOSURE EXISTING PREFAB COOLER SECURITY CHECKLIST: (SOME ITEMS MAY BE NOTED ON Q1.1/Q2.1) Safety and Security /Video Surveillance System Optional Video Equipment • Additional video cameras (interior and exterior). • 13" color monitor should be ceiling mounted near cash register area. Monitor must sequence the exterior camera images and must be readily viewed by cashier. • Interactive Audio /Video Monitoring service provided by approved vendor for 24 -hour interactive off - facility security monitoring service. — EXISTING OVERFILL ALARM & SECURITY CAMERA Required Equipment • 20" color public view monitor should be ceiling mounted at the entrance of store. As the customer enters the facility, the image should be readily seen. • A minimum of 15 "color monitor should be placed in the back office for viewing and monitoring. • Where back office space is limited, a smaller color monitor may be appropriate. • Robot /Sensormatic color (16 port) multiplexer. • Approved time lapse video recorder (best results are obtained in 24 -hour recording mode). O 24 -hour real time audio recording (recorded on 24 -hour video tape). 0 • Approved secure cabinet for recording equipment. • A minimum of five -color video cameras with proper lenses mounted in- store. (4 EXISTING, INSTALL 1 NEW). • A minimum of two exterior mounted cameras with environmental housings to cover operations at the fueling islands. (2 EXTERIOR (1 IS EXISTING)) • Facilities with cash accepting PIC units must have camera coverage for each operable side of the unit. If a single camera cannot view both sides of a dual unit, then additional cameras must be installed to complete coverage. (2 NEW CAMERAS FOR PIC COVERAGE WILL BE REQUIRED) Optional Digital Recorder Requirements • Digital CCTV recording system: Sufficient hard drive space to support 12 color cameras at 5V2 frames per second, per camera, for 31 days. • Audio Recording is required at the Sales Counter Area. . An Audio Processing Kit (Louroe preferred) is required to synchronize the Audio with the Video image. PERFORMANCE REQUIREMENTS: THE MAIN RUNNERS AND CROSS RUNNERS OF THE CEILING SYSTEM AND THEIR SPLICES, INTERSECTION CONNECTORS AND EXPANSION DEVICES SHALL BE DESIGNED AND CON— STRUCTED TO CARRY A MEAN ULTIMATE TEST LOAD OF NOT LESS THAN 180 POUNDS (801 N) OR TWICE THE ACTUAL LOAD, WHICHEVER IS GREATER, IN TENSION WITH 5— DEGREE MISALIGNMENT OF THE MEMBERS IN ANY DIRECTION, AND IN COMPRESSION. IN LIEU OF 5— DEGREE MISALIGNMENT, THE LOAD MAY BE APPLIED WITH A 1 —INCH (25.4MM) ECCENTRICITY ON A SAMPLE NOT MORE THA 24 INCHES (610 MM) LONG ON EACH SIDE OF THE SPLICE. THE CONNECTIONS AT SPLICES AND INTERSECTIONS SHALL ALL BE OF THE MECHANICAL INTERLOCKING TYPE. A.1.3 SUSPENDED CEILING DETAIL AT WALL 45'MAX. 45' MAX LAY -IN CEILING SUSPENSION SYSTEM SUSPENDED CEILING NOTES: 1. NEW OR ALTERED SUSPENDED CEILING SYSTEM MUST BE HEAVY DUTY SYSTEM CONFORMING TO ASTM C 635 AND C 636. IBC 803.9.1.1 (SDC 'D' OR 'E') 2. SUSPENDED MEMBER GRID MUST BE ATTACHED TO TWO ADJACENT WALLS ON MINIMUM 2" WIDE WALL MOLDINGS OR CLOSURE ANGLES AT THESE WALLS. 3. ENDS OF SUSPENDED MEMBER MAIN RUNNERS AND CROSS RUNNERS MUST BE TIED TOGETHER TO PREVENT DISLOCATION. 4. LIGHT FIXTURES 10Ibs. TO 55Ibs. IN WEIGHT MUST BE SUPPORTED TO STRUCTURE BY AT LEAST TWO #12 GAGE HANGER WIRES, EACH AT TWO OPPOSING SIDES, AND SHALL BE ATTACHED TO SUSPENDED MEMBER GRID AT TWO OPPOSING SIDES. WIRES MAY BE SLACK. 5. HVAC TERMINALS OR REGISTERS 20Ibs. TO 561bs. IN WEIGHT SHALL BE POSITIVELY ATTACHED TO SUSPENDED MEMBER MAIN RUNNERS, OR TO CROSS RUNNERS WITH EQUAL CARRYING CAPACITY , AND MUST ALSO BE SUPPORTED TO STRUCTURE BY AT LEAST TWO #12 GAGE HANGER WIRES AT TWO OPPOSING SIDES. WIRES MAY BE SLACK. ® rillallit1 PROVIDE (2) — -:�'- \ II KICKERS (BOTH \ PARALLEL TO AN PERPENDICULAR T SECURE ANGLES TO \ TRUSS SPAN) \ ROOF STRUCTURE WITH A i — SELF TAPPING SCREWS 1 1 A.1.3 NOT TO EXCEED 6' -0" - -SPLAY BRACE WIRE 8" (MAX.) OR 1/4 LENGTH - OF DIST. TO FIRST MAIN, #12 GAGE MIN. MAIN RUNNER CROSS TEE SCALE: 3/4" = 1 ' -0 SECURE SUPPORT WIRES TO EXISTING STRUCTURE 1/2" EMT - RUN TIGHT TO STRUCTURE ABOVE (4' -0" MAX. FOR 1/2" DIA.) 12 GA. VERTICAL HANGER WIRE COMPRESSION STRUT REQUIRED AT EACH SEISMIC RESTRAINT 12' -0" 0.C. EACH WAY AND WITHIN 6' -0" OF EACH WALL VERTICAL — 12 GA. HANGER WIRE AT 4' —O" 0.C 3/4" EMT — NOTCH OVER MAIN RUNNER DRILL 5/32" HOLE FOR 1/8" BOLT AND LOCK— NUT AFTER CEILING SYSTEM IS LEVELED (4) -12 GA. SPLAY WIRES SPLAYED 90' FROM EACH AND 45° FROM CEILING P WALL TRIM 45* MAX. -- -- -(3) TURNS MIN. IN 1 1 /2 "(TYPICAL ,/ 45' MAX. I . CONT. HORIZ. STRUT TO PREVENT SPREADING OF RUNNERS; 12' 0.C. MAX. 1 `MOUNTING STRUT AND \ I CEILING GROMMET BY \ SECURITY CONTRACTOR \ - i (2) L 5x3" 7 GA. MIN. MOUNTING ANGLES WITH 1/2" BOLTS AND WASHERS ON EACH SIDE TYP. OF (4) SPACING WASHERS BETWEEN ANGLES 3/8" BOLTS FURNISHED WITH ADAPTERS L 1 "x1 "x12 GAGE SPLIT PIPE CLAMP ERICO OR APPROVED - MOUNTING STRUT AND CEILING GROMMET BY SECURITY CONTRACTOR REVIEWED POF CODE COMPLIANT APP,- OVED OTHER JUL 1 7 2009 ( ANE City of Tukwila IVISIpi GENERAL NOTES: A. ALL DIMENSIONS SHOWN ON REFLECTED CEILING PLAN ARE FROM FACE OF WALL FINISH UNLESS NOTED OTHERWISE B. POINT LIGHTS FOR INTERIOR SIGNAGE ARE TO HAVE THE WIRING RAN, BUT LIGHTS SHALL NOT BE INSTALLED UNTIL SIGNAGE HAS BEEN HUNG. C. ALL BACKROOM CEILING TILES ARE TO BE REPLACED PER HEALTH DEPARTMENT REQUIREMENTS. D. FLAME SPREAD CLASSIFICATIONS FOR INTERIOR CEILING FINISHES SHALL COMPLY WITH 2006 IBC TABLE 803.5. KEYED NOTES: O INSTALL NEW EXIT SIGN WITH BATTERY BACK UP LIGHTS O NEW OVEN HOOD. REFER TO MECHANICAL SHEETS. O SURFACE MOUNT LIGHT FIXTURES IN THIS AREA. ® EXISTING COOLER /FREEZER LIGHTS TO REMAIN (NOT SHOWN) CEILING FINISH: TYPE: ROCKFON "KORAL" 4'x2'x5/8" (WHITE) SUSPENDED ACOUSTICAL CEILING TILE. FLAME SPREAD CLASS 0 IN I CT -1 I ACCORDANCE WITH BLDG REGULATIONS. CLASS 1 SURFACE SPREAD OF FLAME IN ACCORDANCE WITH BS 476 PART 7. TYPE: USG #3270 "CLIMAPLUS VINYL" 24 "x48 "xY" (WHITE) WASHABLE SUSPENDED CEILING TILE (OR APPROVED EQUAL). CT -2 I FLAME SPREAD 25, CLASS A; SMOKE DEVELOPED: 50; ASTM E84. GRID: CHICAGO METALLIC GRID — EXPOSED GRID SYSTEM (FLAT WHITE) TYPE: i" GYPSUM WALLBOARD, SMOOTH FINISH (MTL FRAMING 2.5" STUDS © 16" O.C.) TYPE: EXISTING STANDING SEAM SHEET METAL CEILING SYMBOL UST I LAY —IN FLUORESCENT (SEE ELECTRICAL FOR SPEC.) (R) (M) — MOVE LIGHTING /FIXTURE \ (R) — RELOCATED LIGHTING /FIXTURE (N) f—(N) — NEW LIGHTING () — (D) — LIGHTING TO BE DEMO'D NO LETTER — EXISTING TO REMAIN NEW CEILING TILES (TYPE AS SPECIFIED) NEW GRID AS REQUIRED v q EGRESS FIXTURES �� II i �G I I ' 33 SUPPLY AIR DIFFUSER TO BE MOVED 0 1111-5 IIII SUPPLY AIR DIFFUSER I O -- - ? (M) RETURN AIR GRILLE TO BE MOVED ( (R) RETURN AIR GRILLE TO BE RELOCATED r : EXHAUST OR RELIEF AIR VENT 108' — CEILING ELEVATION GB CEILING MATERIAL P -2 CEILING FINISH EM EMERGENCY FIXTURES, REFER TO ELECTRICAL LIGHTING PLAN FOR MORE INFORMATION 1= SECURITY CAMERA (APPROXIMATE LOCATION) "PRESCOLITE" AKTHLCE218 FLUORESCENT 4$'' ' '"� ► TRACK LIGHTING USE TWO (2) 18W HIGH LUMEN CFL RS LAMPS 1 I CCTV MONITORS INTERIOR PAINTS: ICI #A0090 — "CANDLE WAX" EGGSHELL FINISH ICI #A1807 — "WATER CHESTNUT" SEMI —GLOSS ICI #A0717 — "INDIAN CORN" ICI #A0409 — "RED BADGE" COLOR: BP HIGH HIDING WHITE ICI BP HIGH HIDING WHITE (CUSTOM) I WHITE EXTERIOR PAINTS: REFER TO EXTERIOR ELEVATIONS FOR FINISH SPECIFICATIONS I WHITE RECEIVED CITY OF TUKWILA JUL U 8 •/IIIIy PERMIT CENTER CLIENT: AkIk O ARCO BP WEST COAST PRODUCTS, LLC 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES 05.26.09 06.05.09 06.23.09 REVISION DESCRIPTION PERMIT REVIEW — BP ISSUED FOR PERMIT — CITY SIGN PERMIT REVIEW — CITY SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: AWANCE Z &DM: BP REPM: AWANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: REFLECTED CEILING PLAN SHEET NO: 1 C -09 1 .iIlI .._ _�.un■lion■an,�� Ir■ ■■ ■It•■ ■■ ■1�� 0 ■1�■ ■■r������ �■■ �■ � � I / ■ It•■■■■ 1�■■■■ 1�► i■■■ 1�■■■■ Is■■■■ It �� • �■■►: r�■■■ 1�■■ ■ ■1�� ■ ■ ■1�■ ■ ■ ■1�� ■ ■ ■It•■ ■ ■ ■It i •■ ` �l''�l'm�%Ir11.e1n11ImmrlD J w t 11 LAM M. C -09 a FRONT (SOUTH) ELEVATION SCALE: 3/16 " =1' -0" LEFT (WEST) ELEVATION SCALE: 3/16 " =1'-0" RIGHT (EAST) ELEVATION SCALE: 3/16 " =1' -0" REAFt APPROXIMATE LOCATION OF OLD OVERHEAD DOOR & HEADER EXISTING MECH. EQUIPMENT SLAB APPROXIMATE LOCATION OF SCALE: 3/16 " =1' -0" REMOVE EXISTING DECAL(S) FROM CANOPY, PAINT C -09 AND INSTALL 15" HIGH 3D DECAL w /LASER LINE ATION NEW 18" DIA. (1.8sf) NON— ILLUMINATED CANOPY LOGO ON EXISTING FASCIA — EAST FACE 56' LENGTH OF /3D DECK. (VLF.) NEW IURBINE EXHAUSI FAN FOR TYPE II HOOD, EXHAUST TO BE 30" MIN. ABV. ADJACENT ROOF C -09 C -09 INSTALL 13" INTERNALLY NATED CHANNEL LETTER 1 C -09 1 REMOVE EXISTING DECAL(S) FROM CANOPY, PAINT C -09 AND INSTALL 15" HIGH 3D DECAL w /LASER LINE — ALIGN LEFT SIDE OF WALL ' b FINISH WITH BATTEN IN THIS AREA C —o9 irrr L rllrlir .i. •JrnuluIuIMI ®IHuI ■IuIpI III®I■Iu FIFTH lII/IL_ !III IIIiIIIulIII1(IlIIIuIlREI E II 11 Il! f■; II1 ■1GI� t El It� rv ' T I 1 'WHIG u X 11 I L� �1I1J_Il.! a I i I 1 1 L t,e_ u. L 1i II f EfEY,1 REMOVE & REINSTALL CAMERA AND OVERFILL ALARM /SWITCH AFTER COMPLETION OF CEMENT PLASTER INSTALLATION EXISTING VENT RISERS, BEYOND 1 C-09 1 56' - 0" 3D DECAL LENGTH (V.LF) NEW 18" DIA. (1.8sf) NON— ILLUMINATED CANOPY LOGO ON EXISTING FASCIA — WEST FACE CLEARANCE SIGN FINISHED EDGE OF CEMENT DI ACTCD CLIAI I CMl AT AVIDTU NEW 18" DIA. (1.8sf) NON— ILLUMINATED CANOPY LOGO ON EXISTING FASCIA — WEST FACE C -09 EXISTING COLUMN MTD. PIC UNIT — FUEL POSmON FLAG SIGNS, TYP. OF 4 EXISTING DISPENSER ISLAND FORMS TO BE PAINTED BP WARM GREY — ICI #A1860 "GREY MOUNTAIN ", TYPICAL FRONT (SOUTH) CANOPY ELEVATION SCALE: 3/1 " =1' -0" 1 c —o91 i III Irr ` r C -09 l C -09 ■1m■.m ■I...mm mummmmummmnmmmm■■■■1 ■■■■1 ■■■■. .. .. . . ■1 ■mi ■■e . . . . 1.■.■ ■m■..■1m■■ Himms.gmxmi. C -09 C -09 �::i = :• 1 r-r t1:. I :1 111 1. !'L:i.1 • '1 . 1`1�`l�.I•I�i I :1'.. '1'. • 1 f: `1: 11 1:•.1 1 1.1,.1.1 1 •I: l :�: 11;1 I 1 i•ij 1 :;l 1-c o9 • • I1111H • '.1 1 1.1 1 1 1.1;i f 1{ 'l l I I 1:1.1.1 1 1 1 1 I I•: 1 1 f. J • 1: I I . I I :1' 1 :I: i 1' 1 • • 1 7 .1 I T• I I I:t'•1 1.I E • 1. • •I•i ..E..�f f t 't. C -09 tt (�I�1wf�I�I C -09 ■ ■■ ■ ■Ir ■ ■■ ■■fir ■ ■■■ ■Irk ■■ ■r ■Iii ■■��■ ■■m ■■ r.„■ C 09 7 .r.T•T .r' T •J . .1.1,1 1'•1:1.1 . ..Y. 1 1 '1.1 1.1 1.. :1 . { ±15' -0" END OF CEMENT PLASTER WHEN NEW ABMS DUSTING C -10 DURACOLOR #1758257 — 15" 3D DECAL FOR FLAT FASCIA CANOPY STRIPE: USE #1758259 0 BUILDING SIDE END (LH ROUNDED ENDCAP) 0 EXISTING BOLLARD TO BE PAINTED BP YELLOW TOP 1/3 & BP PEARL BOTTOM (TYPICAL) PER SECTION 19.32.160(3). TWO UNUGHTED DOUBLE —FACED SIGNS NOT EXCEEDING 20sf PER FACE ARE PERMITTED. SUCH SIGNS SHALL BE NON— PORTABLE AND MAY BE USED FOR ADVERTISING COPY CUSTOMARILY DISPLAYED IN SERVICE STATIONS. FUEL POSITION FLAG SIGN, TYP. OF 4 EXISTING DISPENSER ISLAND FORMS TO BE PAINTED BP WARM GREY — ICI #A1860 "GREY MOUNTAIN ", TYPICAL INSTALL CANOPY HEAD CLEARANCE SIGN — PLACE OVER STREET SIDE ISLANDS, TYP, WEST & EAST SIDES PER SECTION 19.32.160(3). IWO UNLIGHTED DOUBLE —FACED SIGNS NOT EXCEEDING 20sf PER FACE ARE PERMITTED. SUCH SIGNS SHALL BE NON — PORTABLE AND MAY BE USED FOR ADVERTISING COPY CUSTOMARILY DISPLAYED IN SERVICE STATIONS. EXISTING DISPENSER ISLAND FORMS TO BE PAINTED BP WARM GREY — ICI #A1860 "GREY MOUNTAIN ", TYPICAL DURACOLOR #1758257 — 15" 3D DECAL FOR FLAT FASCIA CANOPY STRIPE: USE #1758258 0 BUILDING SIDE END (RH ROUNDED ENDCAP) — INSTALL PUMP NUMBER BLADE SIGN 61 10' -6" ABOVE GRADE, TYPICAL OVER EA. DISPENSER ■■■■■ 1■■■■■■ 111111■ 1111111MIM■■1 ■1.11■11111■111M■II■1I■1.11■1NII■■■ ■ice■ ■■■lIMILVA I■■■■ 1NIII■■■■ 1111111■ ■■ ■1111111■ ■■ ■1•1111■ ■■■1M■■■■1NII■ ■ ■ ■111111■ ■■■III■■ ■r■MUNI nlr ■ ■ ■■ ■11111/111■ MINN 1111111 L I 1111 U INSTALL CANOPY HEAD CLEARANCE SIGN O EXISTING BOLLARD TO BE PAINTED BP YELLOW TOP 1/3 & BP PEARL BOTTOM (TYPICAL) t1 V - 0* C -09 1 VENTS O CHAIN UNK FENCE NOT SHOWN FOR CLARITY DURACOLOR #1758257 — 15" 3D DECAL FOR FLAT FASCIA CANOPY STRIPE: USE #1758260 & #1758261 0 EITHER SIDE OF LOGO & #1758259 0 BUILDING SIDE NEW 18" DIA. (1.8sf) NON— ILLUMINATED CANOPY LOGO ON EXISTING FASCIA — EAST FACE CLEARANCE SIGN REPLACE DISPENSER VALANCES w/ NEW, TYPICAL OF 4 07 EXISTING BOLLARD TO BE PAINTED BP YELLOW TOP 1/3 & BP PEARL BOTTOM (TYPICAL) INSTALL NEW GRAPHICS ON EXISITNG DISPENSERS, TYPICAL GENERAL NOTES: A. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. ALL EXTERIOR ELECTRICAL CONDUITS & UTILITIES TO BE REMOVED UNLESS OTHERWISE NOTED. ANY UT1u1Y BOXES OR CONDUIT TO REMAIN SHALL BE REPAINTED TO MATCH BUILDING. C. GC SHALL INSPECT THE BUILDING PRIOR TO BIDDING AND SHALL REPAIR DAMAGED EXTERIOR FINISHES AND PREPARE THEM FOR REPAINTING OR REFINISHING AS PART OF THEIR SCOPE. KEYED NOTES: 0 0 0 0 0 0 0 1 C -09 1 1 c -1^ NEW PAIR 3'- 6 "x6' -8" DARK BRONZE ANODIZED ALUMINUM STOREFRONT DOORS w/ GEAR HINGES REMOVE (2) EXISTING WINDOWS, IN —FILL WALL NEW BULL NOSE DECAL ON ACM BACKING WITH RED LED BULB PAINT DOOR AND FRAME. NEW BLACK VINYL COATED CHAIN UNK FENCE w/ TAN SLATS, PAINT POLES TO MATCH SLATS. NEW BUMP —OUT ADDION TO EXISTING BUILDING FOR NEW UNISEX ACCESSIBLE REST ROOM. EXTERIOR FINISHES TO MATCH EXISTING METAL SIDING ON 3 SIDES. STANDING SEAM ROOF TO MATCH EXISTING w/ (1) 50SF ROOF VENT. BOLLARDS. PAINTED! C -09 lw/ 1YP. BP SAFETY YELLOW (TOP OF BOLLARD) PREPARE EXISTING EXTERIOR FINISH TO RECEIVE NEW PAINT AS SCHEDULED. PREPARE CONTAINER STORAGE AND PAINT 1 C -09 1(NOT SHOWN, SEE SITE PLAN) REMOVE INTERNALLY ILLUMINATED "ampm" SIGN & MULTI— COLORED FASCIA BAND. 11 INSTALL WINDOW TINT PER PROFILE OF CIGARETTE MERCHANDISER. MATERIAL SUPPLIED AND INSTALLED BY WINDOW TINT INSTALLER/VENDOR ( DURACOLOR OR EQUAL). 7 PROVIDE r CEMENT PLASTER FINISH ON EXISTING AND NEW WALLS IN THESE AREAS; COMPLETE WITH HORIZONTAL RIGLETS WHERE INDICATED. EXISTING BOARD & BAT METAL SIDING ON SOUTH SIDE TO REMAIN. NOT USED NOT USED ILLUMINATED "ampm" SIGNAGE WITH INDMDUAL CHANNEL LETTERS TO BE INSTALLED BY SIGN CONTRACTOR. ARCHITECTURAL BUILDING FEATURES MAY OBSTRUCT 'ampm' CHANNEL LETTERS LOCATE AS INDICATED. CONTACT GA DESIGN MANAGER FOR ALTERNATIVE SOLUTION IF THIS IS THE CASE. 16 EXISTING ELECTRICAL SWITCHGEAR AND PANELS, SEE ELECTRICAL DRAWINGS. EXTERIOR PAINTS COLOR: BP PEARL RAL 1013, ICI #A0083, "INDIAN LEGEND" COLOR: BP DARK PEARL —i ICI #A0767, "DESERT VALLEY" EXISTING EXTERIOR TO BE PAINTED SEMI —GLOSS FINISH: 1ST COAT: S —W LOXON EXTERIOR ACRYLIC MASONRY PRIMER, A24W300 (8 MILS WET, 3.2 MILS DRY) 2ND COAT:. S —W DTM ACRYLIC SEMI —GLOSS COATING, B66 -200 SERIES. 3RD COAT: S -W DTM ACRYLIC SEMI —GLOSS COATING, B66 -200 SERIES. (2 -4 MILS DRY PER COAT) REVIEIrlIEp FOR CODE COMPLIANC E APPROV JUL 1 ' 7 2009 City of Tukwila UILDING DIVISION 1 c —o9 1 RECEIVED CITY OF TUKWILA JUL 0.8 2009 PERMIT CENTER CUENT: ARCO IF BP WEST COAST PRODUCTS, LLC _A T -NG E N G ON 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE 05.26.09 06.05.09 06.23.09 REVISION DESCRIPTION PERMIT REVIEW — BP ISSUED FOR PERMIT — CITY SIGN PERMIT REVIEW — CITY SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALUANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALUANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: ALLIANCE Z &DM: BP REPM: ALLIANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: EXISTING STORE & CANOPY ELEVATIONS SHEET NO: A2.0 Q.a X 1. 1 C -09 1 .iIlI .._ _�.un■lion■an,�� Ir■ ■■ ■It•■ ■■ ■1�� 0 ■1�■ ■■r������ �■■ �■ � � I / ■ It•■■■■ 1�■■■■ 1�► i■■■ 1�■■■■ Is■■■■ It �� • �■■►: r�■■■ 1�■■ ■ ■1�� ■ ■ ■1�■ ■ ■ ■1�� ■ ■ ■It•■ ■ ■ ■It i •■ ` �l''�l'm�%Ir11.e1n11ImmrlD J w t 11 LAM M. C -09 a FRONT (SOUTH) ELEVATION SCALE: 3/16 " =1' -0" LEFT (WEST) ELEVATION SCALE: 3/16 " =1'-0" RIGHT (EAST) ELEVATION SCALE: 3/16 " =1' -0" REAFt APPROXIMATE LOCATION OF OLD OVERHEAD DOOR & HEADER EXISTING MECH. EQUIPMENT SLAB APPROXIMATE LOCATION OF SCALE: 3/16 " =1' -0" REMOVE EXISTING DECAL(S) FROM CANOPY, PAINT C -09 AND INSTALL 15" HIGH 3D DECAL w /LASER LINE ATION NEW 18" DIA. (1.8sf) NON— ILLUMINATED CANOPY LOGO ON EXISTING FASCIA — EAST FACE 56' LENGTH OF /3D DECK. (VLF.) NEW IURBINE EXHAUSI FAN FOR TYPE II HOOD, EXHAUST TO BE 30" MIN. ABV. ADJACENT ROOF C -09 C -09 INSTALL 13" INTERNALLY NATED CHANNEL LETTER 1 C -09 1 REMOVE EXISTING DECAL(S) FROM CANOPY, PAINT C -09 AND INSTALL 15" HIGH 3D DECAL w /LASER LINE — ALIGN LEFT SIDE OF WALL ' b FINISH WITH BATTEN IN THIS AREA C —o9 irrr L rllrlir .i. •JrnuluIuIMI ®IHuI ■IuIpI III®I■Iu FIFTH lII/IL_ !III IIIiIIIulIII1(IlIIIuIlREI E II 11 Il! f■; II1 ■1GI� t El It� rv ' T I 1 'WHIG u X 11 I L� �1I1J_Il.! a I i I 1 1 L t,e_ u. L 1i II f EfEY,1 REMOVE & REINSTALL CAMERA AND OVERFILL ALARM /SWITCH AFTER COMPLETION OF CEMENT PLASTER INSTALLATION EXISTING VENT RISERS, BEYOND 1 C-09 1 56' - 0" 3D DECAL LENGTH (V.LF) NEW 18" DIA. (1.8sf) NON— ILLUMINATED CANOPY LOGO ON EXISTING FASCIA — WEST FACE CLEARANCE SIGN FINISHED EDGE OF CEMENT DI ACTCD CLIAI I CMl AT AVIDTU NEW 18" DIA. (1.8sf) NON— ILLUMINATED CANOPY LOGO ON EXISTING FASCIA — WEST FACE C -09 EXISTING COLUMN MTD. PIC UNIT — FUEL POSmON FLAG SIGNS, TYP. OF 4 EXISTING DISPENSER ISLAND FORMS TO BE PAINTED BP WARM GREY — ICI #A1860 "GREY MOUNTAIN ", TYPICAL FRONT (SOUTH) CANOPY ELEVATION SCALE: 3/1 " =1' -0" 1 c —o91 i III Irr ` r C -09 l C -09 ■1m■.m ■I...mm mummmmummmnmmmm■■■■1 ■■■■1 ■■■■. .. .. . . ■1 ■mi ■■e . . . . 1.■.■ ■m■..■1m■■ Himms.gmxmi. C -09 C -09 �::i = :• 1 r-r t1:. I :1 111 1. !'L:i.1 • '1 . 1`1�`l�.I•I�i I :1'.. '1'. • 1 f: `1: 11 1:•.1 1 1.1,.1.1 1 •I: l :�: 11;1 I 1 i•ij 1 :;l 1-c o9 • • I1111H • '.1 1 1.1 1 1 1.1;i f 1{ 'l l I I 1:1.1.1 1 1 1 1 I I•: 1 1 f. J • 1: I I . I I :1' 1 :I: i 1' 1 • • 1 7 .1 I T• I I I:t'•1 1.I E • 1. • •I•i ..E..�f f t 't. C -09 tt (�I�1wf�I�I C -09 ■ ■■ ■ ■Ir ■ ■■ ■■fir ■ ■■■ ■Irk ■■ ■r ■Iii ■■��■ ■■m ■■ r.„■ C 09 7 .r.T•T .r' T •J . .1.1,1 1'•1:1.1 . ..Y. 1 1 '1.1 1.1 1.. :1 . { ±15' -0" END OF CEMENT PLASTER WHEN NEW ABMS DUSTING C -10 DURACOLOR #1758257 — 15" 3D DECAL FOR FLAT FASCIA CANOPY STRIPE: USE #1758259 0 BUILDING SIDE END (LH ROUNDED ENDCAP) 0 EXISTING BOLLARD TO BE PAINTED BP YELLOW TOP 1/3 & BP PEARL BOTTOM (TYPICAL) PER SECTION 19.32.160(3). TWO UNUGHTED DOUBLE —FACED SIGNS NOT EXCEEDING 20sf PER FACE ARE PERMITTED. SUCH SIGNS SHALL BE NON— PORTABLE AND MAY BE USED FOR ADVERTISING COPY CUSTOMARILY DISPLAYED IN SERVICE STATIONS. FUEL POSITION FLAG SIGN, TYP. OF 4 EXISTING DISPENSER ISLAND FORMS TO BE PAINTED BP WARM GREY — ICI #A1860 "GREY MOUNTAIN ", TYPICAL INSTALL CANOPY HEAD CLEARANCE SIGN — PLACE OVER STREET SIDE ISLANDS, TYP, WEST & EAST SIDES PER SECTION 19.32.160(3). IWO UNLIGHTED DOUBLE —FACED SIGNS NOT EXCEEDING 20sf PER FACE ARE PERMITTED. SUCH SIGNS SHALL BE NON — PORTABLE AND MAY BE USED FOR ADVERTISING COPY CUSTOMARILY DISPLAYED IN SERVICE STATIONS. EXISTING DISPENSER ISLAND FORMS TO BE PAINTED BP WARM GREY — ICI #A1860 "GREY MOUNTAIN ", TYPICAL DURACOLOR #1758257 — 15" 3D DECAL FOR FLAT FASCIA CANOPY STRIPE: USE #1758258 0 BUILDING SIDE END (RH ROUNDED ENDCAP) — INSTALL PUMP NUMBER BLADE SIGN 61 10' -6" ABOVE GRADE, TYPICAL OVER EA. DISPENSER ■■■■■ 1■■■■■■ 111111■ 1111111MIM■■1 ■1.11■11111■111M■II■1I■1.11■1NII■■■ ■ice■ ■■■lIMILVA I■■■■ 1NIII■■■■ 1111111■ ■■ ■1111111■ ■■ ■1•1111■ ■■■1M■■■■1NII■ ■ ■ ■111111■ ■■■III■■ ■r■MUNI nlr ■ ■ ■■ ■11111/111■ MINN 1111111 L I 1111 U INSTALL CANOPY HEAD CLEARANCE SIGN O EXISTING BOLLARD TO BE PAINTED BP YELLOW TOP 1/3 & BP PEARL BOTTOM (TYPICAL) t1 V - 0* C -09 1 VENTS O CHAIN UNK FENCE NOT SHOWN FOR CLARITY DURACOLOR #1758257 — 15" 3D DECAL FOR FLAT FASCIA CANOPY STRIPE: USE #1758260 & #1758261 0 EITHER SIDE OF LOGO & #1758259 0 BUILDING SIDE NEW 18" DIA. (1.8sf) NON— ILLUMINATED CANOPY LOGO ON EXISTING FASCIA — EAST FACE CLEARANCE SIGN REPLACE DISPENSER VALANCES w/ NEW, TYPICAL OF 4 07 EXISTING BOLLARD TO BE PAINTED BP YELLOW TOP 1/3 & BP PEARL BOTTOM (TYPICAL) INSTALL NEW GRAPHICS ON EXISITNG DISPENSERS, TYPICAL GENERAL NOTES: A. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. ALL EXTERIOR ELECTRICAL CONDUITS & UTILITIES TO BE REMOVED UNLESS OTHERWISE NOTED. ANY UT1u1Y BOXES OR CONDUIT TO REMAIN SHALL BE REPAINTED TO MATCH BUILDING. C. GC SHALL INSPECT THE BUILDING PRIOR TO BIDDING AND SHALL REPAIR DAMAGED EXTERIOR FINISHES AND PREPARE THEM FOR REPAINTING OR REFINISHING AS PART OF THEIR SCOPE. KEYED NOTES: 0 0 0 0 0 0 0 1 C -09 1 1 c -1^ NEW PAIR 3'- 6 "x6' -8" DARK BRONZE ANODIZED ALUMINUM STOREFRONT DOORS w/ GEAR HINGES REMOVE (2) EXISTING WINDOWS, IN —FILL WALL NEW BULL NOSE DECAL ON ACM BACKING WITH RED LED BULB PAINT DOOR AND FRAME. NEW BLACK VINYL COATED CHAIN UNK FENCE w/ TAN SLATS, PAINT POLES TO MATCH SLATS. NEW BUMP —OUT ADDION TO EXISTING BUILDING FOR NEW UNISEX ACCESSIBLE REST ROOM. EXTERIOR FINISHES TO MATCH EXISTING METAL SIDING ON 3 SIDES. STANDING SEAM ROOF TO MATCH EXISTING w/ (1) 50SF ROOF VENT. BOLLARDS. PAINTED! C -09 lw/ 1YP. BP SAFETY YELLOW (TOP OF BOLLARD) PREPARE EXISTING EXTERIOR FINISH TO RECEIVE NEW PAINT AS SCHEDULED. PREPARE CONTAINER STORAGE AND PAINT 1 C -09 1(NOT SHOWN, SEE SITE PLAN) REMOVE INTERNALLY ILLUMINATED "ampm" SIGN & MULTI— COLORED FASCIA BAND. 11 INSTALL WINDOW TINT PER PROFILE OF CIGARETTE MERCHANDISER. MATERIAL SUPPLIED AND INSTALLED BY WINDOW TINT INSTALLER/VENDOR ( DURACOLOR OR EQUAL). 7 PROVIDE r CEMENT PLASTER FINISH ON EXISTING AND NEW WALLS IN THESE AREAS; COMPLETE WITH HORIZONTAL RIGLETS WHERE INDICATED. EXISTING BOARD & BAT METAL SIDING ON SOUTH SIDE TO REMAIN. NOT USED NOT USED ILLUMINATED "ampm" SIGNAGE WITH INDMDUAL CHANNEL LETTERS TO BE INSTALLED BY SIGN CONTRACTOR. ARCHITECTURAL BUILDING FEATURES MAY OBSTRUCT 'ampm' CHANNEL LETTERS LOCATE AS INDICATED. CONTACT GA DESIGN MANAGER FOR ALTERNATIVE SOLUTION IF THIS IS THE CASE. 16 EXISTING ELECTRICAL SWITCHGEAR AND PANELS, SEE ELECTRICAL DRAWINGS. EXTERIOR PAINTS COLOR: BP PEARL RAL 1013, ICI #A0083, "INDIAN LEGEND" COLOR: BP DARK PEARL —i ICI #A0767, "DESERT VALLEY" EXISTING EXTERIOR TO BE PAINTED SEMI —GLOSS FINISH: 1ST COAT: S —W LOXON EXTERIOR ACRYLIC MASONRY PRIMER, A24W300 (8 MILS WET, 3.2 MILS DRY) 2ND COAT:. S —W DTM ACRYLIC SEMI —GLOSS COATING, B66 -200 SERIES. 3RD COAT: S -W DTM ACRYLIC SEMI —GLOSS COATING, B66 -200 SERIES. (2 -4 MILS DRY PER COAT) REVIEIrlIEp FOR CODE COMPLIANC E APPROV JUL 1 ' 7 2009 City of Tukwila UILDING DIVISION 1 c —o9 1 RECEIVED CITY OF TUKWILA JUL 0.8 2009 PERMIT CENTER CUENT: ARCO IF BP WEST COAST PRODUCTS, LLC _A T -NG E N G ON 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE 05.26.09 06.05.09 06.23.09 REVISION DESCRIPTION PERMIT REVIEW — BP ISSUED FOR PERMIT — CITY SIGN PERMIT REVIEW — CITY SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALUANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALUANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: ALLIANCE Z &DM: BP REPM: ALLIANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: EXISTING STORE & CANOPY ELEVATIONS SHEET NO: A2.0 Q.a X 100' -0" T.O. SLAB A.2.3 A.2.3 A.2.3 B 14A 1'lul'Iul'►iil'1 FCB & FOUNTAIN & ToGo SCALE: 3/8 " =1' -0" DOORS R S SCALE: 3/8 " =1' -0" REINSTALL INTERNALLY ILLUMINATED SIGN V14 4' -6" A2.3 1 0.44D SECTION @ ToGo SCALE: 3/8 " =1' -0" 3' -7" , 5" WOOD SHELF BRACKET r FOR TOP SUPPORT METAL CAB. ADJ. SHELF " w 11.456 CASHIER & FRONT ENTRY EXISTING STOREFRONT 10.447 2' -9" 3' -0" 11.451 06.412 1 1.450a 0.447 11.450 10.447 MAIN ENTRY A.2.3 A.2.3 10.447 Rra 12' -0" COFFEE o Di DD c C DD iD C Old Milli F MR go gra w - 1 I!lI1111I111111I111111I111111I11111111111111i=:I1111 ampm COFFEE SCALE: 3/8 "= l'- 0" 10.447 7' -0" SCALE: 3/8 " =1'— 0" C11 ) [T1 lI11H1 SECTION @ CASHIER 46 "x12.75" To Go - HOT FOOD SCALE: 3/8 " =1' -0" EXISTING CIGARETTE DISPLAY TG1OB 10.447 MICRO 06.412 A. FOR EQUIPMENT PLAN REFER TO SHEET Q1.1. B. FOR EQUIPMENT SCHEDULE REFER TO SHEET Q2.1 C. ALL EQUIPMENT SHALL MEET LOCAL HANDICAPPED REQUIREMENTS D. PRIME GYPSUM BOARD PRIOR TO INSTALLATION OF GRAPHICS E. PROVIDE PLASTIC CORNER GUARDS AT EDGES BELOW 6' -0" 06.412 PROVIDE FINISH ON CABINETS ENDS AS REQUIRED 09.260 CLEAR PLASTIC CORNER GUARDS 10.447 SIGNAGE, REFER TO GRAPHIC SCHEDULE ON SHEET Q2.2 10.451 HANDICAPPED RESTROOM SIGNAGE. 10.448 DIGITALLY PRINTED WALL PAPER REFER TO GRAPHIC SCHEDULE ON SHEET Q2.2 1 1.405 EXISTING COOLER /FREEZER DOORS 11.406 PLEXIGLAS SPLASH GUARD 1 1.450 PAINTED METAL CABINETS 171.450a OPTION 6 - WOOD CABINETS W/ - PLASTIC LAMINATE FINISH 11.451 SOLID SURFACE COUNTERTOP 11.451a PLASTIC LAMINATE COUNTERTOP 1 1.452 STAINLESS STEEL COUNTERTOP W/ 4" CURB AROUND EDGES 1 1.456 PROVIDE FILLER COUNTER AND MILLWORK FOR GAP WITH FINISHES TO MATCH SUBSTRATE: j TYPE: $' GYPSUM BOARD TYPE: e' MOISTURE - RESISTANT GYPSUM BOARD WALL FINISH: FIBER REINFORCED PANEL COLOR: WHITE BY: KEMLITE (85) OR MARLITE (FRP S100G) WALL BASE V -1 COLOR: 130 "BUCKSKIN" BY: ROPPE SIZE: %8'x6" COVE BASE LOCATION: BACK ROOM V -2 I COLOR: 193 "BLACK BROWN" BY: ROPPE SIZE: a'x6" COVE BASE LOCATION: SALES AREA COUNTER TOP SS -1 WILSONART 1530 -TM "BEIGE TEMPEST" SOLID SURFACE MATERIAL SS -2 STAINLESS STEEL L -4 WILSONART 4143 -60 "NEUTRAL GLACE PLASTIC LAMINATE L -5 WILSONART #6277 (419) ALUMASTEEL PLASTIC LAMINATE INTERIOR PAINTS: ICI #A0090 - "CANDLE WAX" EGGSHELL FINISH ICI #A1807 - "WATER CHESTNUT' SEMI -GLOSS PANTONE PMS 422C - "DOVE GREY" ICI #A0409 - "RED BADGE" ICI #A0731 "DAKOTA LAND LAMINATES: COLORS TO BE SELECTED FROM THE FOLLOWING: WOOD LAMINATES - WILSONART #7909 -60 FUSION MAPLE PLASTIC LAMINATE - WILSONART #D92 -60 DOVE GREY O TACTILE SIGN READING "EXIT", GRADE 2 BRAILLE 60" TO CENTER FROM FLOOR 4 "x6 ", 1/4" NON -GLARE (MATTE) ACRYUC, GREEN BACK- GROUND w/ WHITE LETTERING TACTILE SIGNS, RAISED LAMINATE TEXT & SYMBOL, 2 CONTRAS11NG COLOR & POSSESSING MIN. OF 5/8" H. RAISED LETTERS (MAX. 2" HIGH) AS SHOWN; GRADE 2 BRAILLE 0 BOTTOM OF SIGN. THE BORDER RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER CLIENT: Akilk ARCO BP WEST COAST PRODUCTS, LLC 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES 05.26.09 06.05.09 06.23.09 REVISION DESCRIPTION PERMIT REVIEW — BP ISSUED FOR PERMIT - CITY SIGN PERMIT REVIEW — CITY SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: AWANCE Z &DM: BP REPM: AWANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: INTERIOR ELEVATIONS SHEET NO: tor 44 oom ..]otin IAMI 0 0 i' 1 i, or mind iiii I II iin EIJI IE Ili : . 100' -0" T.O. SLAB A.2.3 A.2.3 A.2.3 B 14A 1'lul'Iul'►iil'1 FCB & FOUNTAIN & ToGo SCALE: 3/8 " =1' -0" DOORS R S SCALE: 3/8 " =1' -0" REINSTALL INTERNALLY ILLUMINATED SIGN V14 4' -6" A2.3 1 0.44D SECTION @ ToGo SCALE: 3/8 " =1' -0" 3' -7" , 5" WOOD SHELF BRACKET r FOR TOP SUPPORT METAL CAB. ADJ. SHELF " w 11.456 CASHIER & FRONT ENTRY EXISTING STOREFRONT 10.447 2' -9" 3' -0" 11.451 06.412 1 1.450a 0.447 11.450 10.447 MAIN ENTRY A.2.3 A.2.3 10.447 Rra 12' -0" COFFEE o Di DD c C DD iD C Old Milli F MR go gra w - 1 I!lI1111I111111I111111I111111I11111111111111i=:I1111 ampm COFFEE SCALE: 3/8 "= l'- 0" 10.447 7' -0" SCALE: 3/8 " =1'— 0" C11 ) [T1 lI11H1 SECTION @ CASHIER 46 "x12.75" To Go - HOT FOOD SCALE: 3/8 " =1' -0" EXISTING CIGARETTE DISPLAY TG1OB 10.447 MICRO 06.412 A. FOR EQUIPMENT PLAN REFER TO SHEET Q1.1. B. FOR EQUIPMENT SCHEDULE REFER TO SHEET Q2.1 C. ALL EQUIPMENT SHALL MEET LOCAL HANDICAPPED REQUIREMENTS D. PRIME GYPSUM BOARD PRIOR TO INSTALLATION OF GRAPHICS E. PROVIDE PLASTIC CORNER GUARDS AT EDGES BELOW 6' -0" 06.412 PROVIDE FINISH ON CABINETS ENDS AS REQUIRED 09.260 CLEAR PLASTIC CORNER GUARDS 10.447 SIGNAGE, REFER TO GRAPHIC SCHEDULE ON SHEET Q2.2 10.451 HANDICAPPED RESTROOM SIGNAGE. 10.448 DIGITALLY PRINTED WALL PAPER REFER TO GRAPHIC SCHEDULE ON SHEET Q2.2 1 1.405 EXISTING COOLER /FREEZER DOORS 11.406 PLEXIGLAS SPLASH GUARD 1 1.450 PAINTED METAL CABINETS 171.450a OPTION 6 - WOOD CABINETS W/ - PLASTIC LAMINATE FINISH 11.451 SOLID SURFACE COUNTERTOP 11.451a PLASTIC LAMINATE COUNTERTOP 1 1.452 STAINLESS STEEL COUNTERTOP W/ 4" CURB AROUND EDGES 1 1.456 PROVIDE FILLER COUNTER AND MILLWORK FOR GAP WITH FINISHES TO MATCH SUBSTRATE: j TYPE: $' GYPSUM BOARD TYPE: e' MOISTURE - RESISTANT GYPSUM BOARD WALL FINISH: FIBER REINFORCED PANEL COLOR: WHITE BY: KEMLITE (85) OR MARLITE (FRP S100G) WALL BASE V -1 COLOR: 130 "BUCKSKIN" BY: ROPPE SIZE: %8'x6" COVE BASE LOCATION: BACK ROOM V -2 I COLOR: 193 "BLACK BROWN" BY: ROPPE SIZE: a'x6" COVE BASE LOCATION: SALES AREA COUNTER TOP SS -1 WILSONART 1530 -TM "BEIGE TEMPEST" SOLID SURFACE MATERIAL SS -2 STAINLESS STEEL L -4 WILSONART 4143 -60 "NEUTRAL GLACE PLASTIC LAMINATE L -5 WILSONART #6277 (419) ALUMASTEEL PLASTIC LAMINATE INTERIOR PAINTS: ICI #A0090 - "CANDLE WAX" EGGSHELL FINISH ICI #A1807 - "WATER CHESTNUT' SEMI -GLOSS PANTONE PMS 422C - "DOVE GREY" ICI #A0409 - "RED BADGE" ICI #A0731 "DAKOTA LAND LAMINATES: COLORS TO BE SELECTED FROM THE FOLLOWING: WOOD LAMINATES - WILSONART #7909 -60 FUSION MAPLE PLASTIC LAMINATE - WILSONART #D92 -60 DOVE GREY O TACTILE SIGN READING "EXIT", GRADE 2 BRAILLE 60" TO CENTER FROM FLOOR 4 "x6 ", 1/4" NON -GLARE (MATTE) ACRYUC, GREEN BACK- GROUND w/ WHITE LETTERING TACTILE SIGNS, RAISED LAMINATE TEXT & SYMBOL, 2 CONTRAS11NG COLOR & POSSESSING MIN. OF 5/8" H. RAISED LETTERS (MAX. 2" HIGH) AS SHOWN; GRADE 2 BRAILLE 0 BOTTOM OF SIGN. THE BORDER RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER CLIENT: Akilk ARCO BP WEST COAST PRODUCTS, LLC 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES 05.26.09 06.05.09 06.23.09 REVISION DESCRIPTION PERMIT REVIEW — BP ISSUED FOR PERMIT - CITY SIGN PERMIT REVIEW — CITY SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: AWANCE Z &DM: BP REPM: AWANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: INTERIOR ELEVATIONS SHEET NO: tor 44 oom ..]otin IAMI 0 0 or mind 100' -0" T.O. SLAB A.2.3 A.2.3 A.2.3 B 14A 1'lul'Iul'►iil'1 FCB & FOUNTAIN & ToGo SCALE: 3/8 " =1' -0" DOORS R S SCALE: 3/8 " =1' -0" REINSTALL INTERNALLY ILLUMINATED SIGN V14 4' -6" A2.3 1 0.44D SECTION @ ToGo SCALE: 3/8 " =1' -0" 3' -7" , 5" WOOD SHELF BRACKET r FOR TOP SUPPORT METAL CAB. ADJ. SHELF " w 11.456 CASHIER & FRONT ENTRY EXISTING STOREFRONT 10.447 2' -9" 3' -0" 11.451 06.412 1 1.450a 0.447 11.450 10.447 MAIN ENTRY A.2.3 A.2.3 10.447 Rra 12' -0" COFFEE o Di DD c C DD iD C Old Milli F MR go gra w - 1 I!lI1111I111111I111111I111111I11111111111111i=:I1111 ampm COFFEE SCALE: 3/8 "= l'- 0" 10.447 7' -0" SCALE: 3/8 " =1'— 0" C11 ) [T1 lI11H1 SECTION @ CASHIER 46 "x12.75" To Go - HOT FOOD SCALE: 3/8 " =1' -0" EXISTING CIGARETTE DISPLAY TG1OB 10.447 MICRO 06.412 A. FOR EQUIPMENT PLAN REFER TO SHEET Q1.1. B. FOR EQUIPMENT SCHEDULE REFER TO SHEET Q2.1 C. ALL EQUIPMENT SHALL MEET LOCAL HANDICAPPED REQUIREMENTS D. PRIME GYPSUM BOARD PRIOR TO INSTALLATION OF GRAPHICS E. PROVIDE PLASTIC CORNER GUARDS AT EDGES BELOW 6' -0" 06.412 PROVIDE FINISH ON CABINETS ENDS AS REQUIRED 09.260 CLEAR PLASTIC CORNER GUARDS 10.447 SIGNAGE, REFER TO GRAPHIC SCHEDULE ON SHEET Q2.2 10.451 HANDICAPPED RESTROOM SIGNAGE. 10.448 DIGITALLY PRINTED WALL PAPER REFER TO GRAPHIC SCHEDULE ON SHEET Q2.2 1 1.405 EXISTING COOLER /FREEZER DOORS 11.406 PLEXIGLAS SPLASH GUARD 1 1.450 PAINTED METAL CABINETS 171.450a OPTION 6 - WOOD CABINETS W/ - PLASTIC LAMINATE FINISH 11.451 SOLID SURFACE COUNTERTOP 11.451a PLASTIC LAMINATE COUNTERTOP 1 1.452 STAINLESS STEEL COUNTERTOP W/ 4" CURB AROUND EDGES 1 1.456 PROVIDE FILLER COUNTER AND MILLWORK FOR GAP WITH FINISHES TO MATCH SUBSTRATE: j TYPE: $' GYPSUM BOARD TYPE: e' MOISTURE - RESISTANT GYPSUM BOARD WALL FINISH: FIBER REINFORCED PANEL COLOR: WHITE BY: KEMLITE (85) OR MARLITE (FRP S100G) WALL BASE V -1 COLOR: 130 "BUCKSKIN" BY: ROPPE SIZE: %8'x6" COVE BASE LOCATION: BACK ROOM V -2 I COLOR: 193 "BLACK BROWN" BY: ROPPE SIZE: a'x6" COVE BASE LOCATION: SALES AREA COUNTER TOP SS -1 WILSONART 1530 -TM "BEIGE TEMPEST" SOLID SURFACE MATERIAL SS -2 STAINLESS STEEL L -4 WILSONART 4143 -60 "NEUTRAL GLACE PLASTIC LAMINATE L -5 WILSONART #6277 (419) ALUMASTEEL PLASTIC LAMINATE INTERIOR PAINTS: ICI #A0090 - "CANDLE WAX" EGGSHELL FINISH ICI #A1807 - "WATER CHESTNUT' SEMI -GLOSS PANTONE PMS 422C - "DOVE GREY" ICI #A0409 - "RED BADGE" ICI #A0731 "DAKOTA LAND LAMINATES: COLORS TO BE SELECTED FROM THE FOLLOWING: WOOD LAMINATES - WILSONART #7909 -60 FUSION MAPLE PLASTIC LAMINATE - WILSONART #D92 -60 DOVE GREY O TACTILE SIGN READING "EXIT", GRADE 2 BRAILLE 60" TO CENTER FROM FLOOR 4 "x6 ", 1/4" NON -GLARE (MATTE) ACRYUC, GREEN BACK- GROUND w/ WHITE LETTERING TACTILE SIGNS, RAISED LAMINATE TEXT & SYMBOL, 2 CONTRAS11NG COLOR & POSSESSING MIN. OF 5/8" H. RAISED LETTERS (MAX. 2" HIGH) AS SHOWN; GRADE 2 BRAILLE 0 BOTTOM OF SIGN. THE BORDER RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER CLIENT: Akilk ARCO BP WEST COAST PRODUCTS, LLC 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES 05.26.09 06.05.09 06.23.09 REVISION DESCRIPTION PERMIT REVIEW — BP ISSUED FOR PERMIT - CITY SIGN PERMIT REVIEW — CITY SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ I.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: AWANCE Z &DM: BP REPM: AWANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: INTERIOR ELEVATIONS SHEET NO: 0' -0" T.O. SLAB ±10' -0" (EXISTL B.O. CEILING 7' -0" (EXIST) B.O. SOFFIT @ 7' -6" 0' -O" T.O. SLAB ±10' -0" (EXISTL B.O. CEILING EXISTING SOFFIT EXISTING CEILING I P -1 T P -2 I \ HOT FOOD AREA WB-1 HOT FOOD & BACKROOM DOORS SCALE: 3/8 " =1' -0 I P -1 C EQUAL EXISTING 8 -DOOR COOLER SCALE: 3/8 " =1' -0" GB -1 P -1 / I P -2 BACKROOM ENTRAN1 E V15 COOLER WB -1 24' -3" (V.I.F.) 198" V26 CORRESPONDING BRAILLE SCALE: 3/8 " =1' -0" EX. METAL SOFFIT 0006 ESTROOM I WB- UNDERCUT DOOR REST ROOM DOOR & SIGN 10.448 D1A ) ti P -2 I P -1 I GB -1 P -1 EQUAL FIELD CUT TO FIT i REVIEWE FO CODE COMPLIANCE APPROVED JUL 17 2009 City of Tukwila BUILDING DIVISION GENERAL NOTES: A. FOR EQUIPMENT PLAN REFER TO SHEET Q1.1. B. FOR EQUIPMENT SCHEDULE REFER TO SHEET Q2.1 C. ALL EQUIPMENT SHALL MEET LOCAL HANDICAPPED REQUIREMENTS. D. PRIME GYPSUM BOARD PRIOR TO INSTALLATION OF GRAPHICS. E. PROVIDE CLEAR PLASTIC CORNER GUARDS AT EDGES BELOW 6' -0 ". KEYED NOTES: O 06.113 CONTRACTOR TO PROVIDE BLOCKING FOR SHELVING AS REQUIRED, DASHED LINES ON ELEVATIONS REPRESENTS APPROXIMATE LOCATION OF BLOCKING 06.120 2x LEDGER 06.196 CONTRACTOR TO SECURE SHELVING BRACKETS DIRECTLY TO STUD OR BLOCKING. 10.800 PAPER TOWEL AND SOAP DISPENSER. 11.406 PLEXIGLAS SPLASH GUARD 11.453 4" PARTITION WITH PLASTIC LAMINATE FINISH L -3. RADIUS CENTER SUPPORT LEG WITH REAR TOP NOTCH AT CENTER SUPPORTS. 16.100 REFER TO ELECTRICAL SHEETS FOR ELECTRICAL EQUIPMENT SUBSTRATE: GB -1 GB-2 WALL FINISH: FIBER REINFORCED PANEL COLOR: WHITE BY: KEMLITE (85) OR MARLITE (FRP S100G) COLOR: ALMOND TYPE: MARLITE C118 -G44, WITH SCORED GRID PATTERN WALL BASE COLOR: #130 "BUCKSKIN" BY: ROPPE SIZE: y8 "x6" COVE BASE. LOCATION: BACK ROOM FRP -1 FRP -3 V - 1 V -2 STAINLESS STEEL PANEL OPTION 1 1 - STAINLESS STEEL WALL PANEL - I INTERIOR PAINTS: P -1 P -2 P -3 P -4 P -5 TYPE: 8' GYPSUM BOARD TYPE: 8' MOISTURE - RESISTANT GYPSUM BOARD COLOR: #193 "BLACK BROWN" BY: ROPPE SIZE: y "x6" COVE BASE LOCATION: SALES ROOM ICI #A0090 - "CANDLE WAX" EGGSHELL FINISH ICI #A1807 - "WATER CHESTNUT' SEMI -GLOSS PANTONE PMS 422C - "DOVE GREY" ICI #A0409 - "RED BADGE" ICI #A0731 "DAKOTA LAND" ADA SIGNAGE O TACTILE SIGN READING "EXIT", GRADE 2 BRAILLE 60" TO CENTER FROM FLOOR 4 "x6 ", 1/4" NON -GLARE (MATTE) ACRYLIC, GREEN BACK- GROUND w/ WHITE LETTERING TACTILE SIGNS, RAISED LAMINATE TEXT & SYMBOL, 2 CONTRASTING COLOR & POSSESSING MIN. OF 5/8" H. RAISED LETTERS (MAX. 2" HIGH) AS SHOWN; GRADE 2 BRAILLE 0 BOTTOM OF SIGN. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE AT LEAST 6" H. RECEIVED CITY OF TUKWILA JUL 0 2009 PERMIT CENTER CLIENT: Aklik ARCO BP WEST COAST PRODUCTS, LLC 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. /1` REVISION DESCRIPTION PERMIT REVIEW - BP A Ae \ A A A DATE 05.26.09 06.05.09 06.23.09 06.23.09 ISSUED FOR PERMIT - CITY SIGN PERMIT REVIEW - CITY RESPONSE TO COMMENTS SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT NE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ 1-5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: ALLIANCE Z &DM: BP REPM: ALLIANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: INTERIOR ELEVATIONS SHEET NO: A2.4 V -1 V - V • G10 MENU FRP -1 P -1 GB -1 P -1 OPEN FIN. FLR. 01 TYPICAL TO GO DELI SCALE: 3/8 " =1 '_0" GB -1 FRP -1 G10 FIN. FLR TYPICAL BAG n BOX SCALE: 3/8 " =1' -0" 08 TYPICAL REFRIGERATOR SCALE: 3/8 " =1' -0" i0 TYPICAL EMPLOYEE LOCKER SCALE: 3/8 " =1' -0" GB -1 P -1 SS -1 V - WB -1 FIN. FLR. TYPICAL 3 -COMP SINK SCALE: 3/8 " =1' -0" GB -1 P -1 GB -2 FRP -1 FIN. FLR. V -1 SCALE: 3/8 " =1' -0 G6B ON ROOF G6A GB -2 FRP -1 1 GB -1 FRP 0 1 TYPICAL WATER PURIFIER TYPICAL ICE MACHINE SCALE: 3/8 " =1' -0" 0 Co NOTE: FOR LOCATIONS REFER TO Q.1.1 GB -1 P -1 5' -O" C55 G55 TG55 FIN. FLR. I V -1 03 TYPICAL FIRE EXTINGUISHER SCALE: 3/8 " =1' -0" TYPICAL STORAGE SHELVES SCALE: 3/8 " =1' -0 - END WALL OR FACE OF WALL CO 1= 0 Li 0 0 0 0 F- x w CD w C.) U) z Lx F- w U FILLER PANEL AS REQUIRED GB -1 P -1 4' -O" 0 r WB -1 GB -1 SS -1 ( TG5 FIN. FLR. TG6 TYPICAL CONVECTION OVEN SCALE: 3/8" =1'- 0" TYPICAL BEHIND SHELVING FIN. FLR. 3' -6" ro NOT USED SCALE: 3/8 " =1' -0" GB -2 FRP -1 FIN. FLR. C6.1 1p WB -1 ( G16 3' -0" GB -1 SS -1 GB -1 FRP -1 FIN. FLR. 00 N CLEAR SPACE X 2' -6" I TYPICAL HAND SINK SCALE: 3/8 " =1' -0" REVIEWED FOR CODE COMPLIANCE '? PPROVED JUL 17 2009 City of Tukwila BUILDING DIVISION 4' -0" (3' -0 ") FIN. FLR. I KEYED NOTES: O 06.113 CONTRACTOR TO PROVIDE BLOCKING AS REQUIRED FOR ALL ACCESSORIES AND SHELVING, DASHED LINES ON ELEVATIONS REPRESENT APPROXIMATE LOCATION OF BLOCKING. 06.196 CONTRACTOR TO SECURE SHELVING BRACKETS DIRECTLY TO STUD OR BLOCKING. 09.260 C- SHAPED CORNER GUARD TO BE 16GA STAINLESS STEEL 10.800 PAPER TOWEL AND SOAP DISPENSER. 15.080 PROVIDE ADA PIPE WRAP ON ALL EXPOSED PIPING. SUBSTRATE: GB -1 GB -2 PLY -1 PLY -2 WALL FINISH: FIBER REINFORCED PANEL FRP -1 COLOR: WHITE BY: KEMLITE (85) OR MARLITE (FRP S100G) COLOR: ALMOND TYPE: LASCO BOARD WP 4'x8' (0.090" THICK) COLOR: ALMOND TYPE: MARLITE C118 -G44, WITH SCORED GRID PATTERN WALL BASE COLOR: #130 "BUCKSKIN" BY: ROPPE SIZE: .Y "x6' COVE BASE LOCATION: BACK ROOM FRP -2 FRP -3 V -1 WB -1 INTERIOR PAINTS: P -1 P -2 P -3 P -4 P -5 TYPE: 8" GYPSUM BOARD TYPE: 8' MOISTURE - RESISTANT GYPSUM BOARD TYPE: a" PLYWOOD TYPE: 8" MDO PLYWOOD COLOR: SAND (P505) BY: DALTILE SIZE: 6 "x13" VERANDA COVE BASE TILE (P505- S36E9T1 P) LOCATION: SALES ROOM & HOT FOOD GROUT: #42 MOCHA ULTRA PRO GROUT 9999624412 (SUPPLIED BY MAPEI) (NOTE: CORNER BASE TILE "SAND" P505, PRODUCT #P505- SC36E9T1 P) ICI #A0090 - "CANDLE WAX" EGGSHELL FINISH ICI #A1807 - "WATER CHESTNUT' SEMI -GLOSS PANTONE PMS 422C - "DOVE GREY" ICI #A0409 - "RED BADGE" ICI #A0731 "DAKOTA LAND" CITY OF TUKWILA JUL 08 2009 PERMIT CENTER CUENT: A \ ARCO BP WEST COAST PRODUCTS, LLC n to G < � "VG EN G 1N � `G I 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. /A\ A n A A DATE 05.26.09 06.05.09 06.23.09 REVISION DESCRIPTION PERMIT REVIEW - BP ISSUED FOR PERMIT- CITY SIGN PERMIT REVIEW - CITY SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALUANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @1 -5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: (NECKED BY: DRAWN BY: VERSION: OM AWANCE Z &DM: BP REPM: AWANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: TYPICAL INTERIOR ELEVATIONS SHEET NO: A2.5 BELOW EXISTING OFFICE � B 13A BELOW EXISTING COVERED TRASH ENCLOSURE B3B • NEW UNISEX REST ROO OVEN `toaster TG10B FRITO BCHE EQUIPMENT FLOOR PLAN SCALE: 1 /4" = 1' -0" HOSTPS,S II SWEET CAKES EXISTING STORAGE =J TANK "A" MONITOR CHILLED I � • U I 11G3A ,,y II��. Ili .�i`IIIJIIi k �'� I�i..0r ,..riuni,�l>, -- Ism •� � - TG11 , T 14 4 G2®- ♦_ basket •elow below A9 ) ��- C 1 A I cabinet mop rack above / handsink EX. ICE CREAM EX. V.I.F. EXISTING STORAGE CONTAINER hood above above 3 CANDY 2dr 3dr FREEZER REFRIGERATOR _.) L. PRIMARY SODA PROMO 1 below CASHIER above 8' CIGARETTES OTP (below) below XISTING W8ES above 3' JERKY PROMO 2 /MVE window rack above 6' -2" EX. V.I.F. AUTO EXISTING PREFAB COOLER REVIEW FO CODE COMPLIANCE APPROVED JUL 17 2009 NOTE: THIS PLAN, AS SHOWN, HAS BEEN APPROVED BY BP MARKETING MANAGEMENT ON APRIL 21, 2009. ANY DEVIATION TO THIS PLAN NEEDS TO BE APPROVED THROUGH NANCY KNOTT, FORMAT DEVELOPMENT MANAGER, BP RETAIL MARKETING AND INCORPORATED INTO THE PERMIT DOCUMENTS. CONTACT FRANCHISEE FOR MORE DETAILS. RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER CUENT: ARCO BP WEST COAST PRODUCTS, LLC 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES 05.26.09 06.05.09 06.23.09 06.23.09 REVISION DESCRIPTION PERMIT REVIEW - BP ISSUED FOR PERMIT - CITY SIGN PERMIT REVIEW - CITY RESPONSE TO COMMENTS SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALUANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALUANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT L &M SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I -5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CHECKED BY: DRAWN BY: VERSION: AWANCE Z &DM: BP REPM: AWANCE PM: PROJECT NO: 1975.75 DRAWING TITLE: SHEET NO: X z 0 C.� t W cr X 11 0 (1) U cL 0" 0) O M QO 0 0 0 0) 0 rn O O 0 U 0) ,-. U 4- 0 10 N rn 0 0 O O O EL CLIENT: f r p EQU IPMENT EQUIPMENT ELECTRICAL PLUMBING REMARKS EQUIPMENT ELECTRICAL PLUMBING REMARKS i'- NO QTY ITEM / DESCRIPTION MANUFACTURER MODEL NUMBER V PH AMP KVA HP SUPPLY WASTE NO QTY ITEM / DESCRIPTION MANUFACTURER � MODEL NUMBER V PH AMP KVA HP SUPPLY WASTE`; POC SIZE POC SIZE COLD HOT COLD HOT A kik. 1 r ARCO BP WEST COAST PRODUCTS LLC A1A 1 CAPPUCCINO MACHINE (5 heads) BUNN (EXISTING) iMIX 5S+ #38100.0003 120V 1 15 1.800 1/4" EXISTING TO BE RELOCATED Fl 1 LOT MANAGER'S DESK EXISTING EXISTING TO REMAIN A2 1 TEA RACK EXISTING EXISTING "ampm" RACK TO E RELOCATEE F2 1 LOT SHELVING ABOVE DESK EXISTING EXISTING TO REMAIN A5 16 COFFEE CUP HOLDERS (Under Counter) IMPRESSIONS / SHOPCO #HDW- CUPDISP- C2410C18 MODIFY EXISTING CABINETS TO ACCEPT F3A 1 LOCKING STORAGE CABINET EXISTING N/A A6 1 ICED LATTE (4 HEAD) BUNN JDF -4 120V 1 9.5 3/8" EXISTING TO BE RELOCATED F4 1 COMPUTER SYSTEM BOS COMPUTER XP BKO 120V 1 1.7 .0.300 UNIT WITH CORD & NEMA 5 -15 PLUG A8 1 ICED CUPHOLDER PLASTICS & PRODUCTS CLS -BP -718 F5 1 CCTV- RECORDER /DVR /MONITOR EXISTING 120V 1 7.0 0.300 EXISTING CAMERAS TO BE RELOCATED PER NEW FLOOR PLAN LAYOUT A9 1 LOT COFFEE CABINETS IMPRESSIONS / SHOPCO MULTIPLE #'S - SEE CUT SHEETS EXISTING MODIFY NEW TOPS/LAMINATE A10 2 DUAL SOFT HEAT BREWER BUNN (EXISTING) #27900.0038 120/208V 1 28.9 5.9 1/4" EXISTING TO BE RELOCATED F6 1 SATEWTE INTERFACE HUGHES NEW A10A 4 DUAL DRIP TRAY KIT BUNN #27150.0000 F7 1 FILE CABINET EXISTING EXISTING TO REMAIN A10B 8 FAUCET COVERS BUNN COVER W/ DECALS #07187.0001 F8 1 MANAGER CHAIR EXISTING EXISTING TO REMAIN Al 1 1 SKINNY SHORT COFFEE CONDIMENT ISLAND - 80 "x30" IMPRESSIONS /SHOPCO #BP- COO- CCI -SK66, # BP -2 CCDPISS F9 1 EMPLOYEE LOCKERS WASSERSTROM VOGEL PETERSON #VOGTR6HMB Al2 4 SINGLE SOFT HEAT STAND BUNN (2 EXISTING / 2 NEW) # SH STAND 27825.0003 120V 1 0.09 EMA 5- RELOCAI � IT WITH XISTI C ENG ORD TO BE & N S F13 1 COAT RACK WASSERSTROM VOGEL PETERSON #CH18 C'J► • {.•� ' 4 u _ - > .,,,- �,,► `' I '' 0 i' � V y ? & q- <T7 NG E N G4 N `G 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES A13 4 SINGLE SOFT HEAT SERVER BUNN (2 EXISTING 2 NEW) ( / #SH SERVER 27850.0004 2 E TO BE RELOCAI �I�IT XISTI WITH C ORD & NMA 5- A13 A 4 ONE POSITION DRIP TRAY KIT BUNN # 26830.0000 BACKROOM G1 1 BULK CO2 FOR POST MIX EXISTING EXISTING TO REMAIN A15 1 LATTE STEAMER BUNN #FMD -1 SET 00.0196 120V 1 15 1.800 3/8" UNIT WITH CORD & NEMA 5-15 PLUG G4 1 LOT DRYING RACK METRO SMARTWALL + BACK GRID A22 2 COFFEE CONDIMENT ORGANIZER PLASTICS & PRODUCTS #CCBP- SKINNY FOR DOGBONE BAKERY COMBO G6A 600L8 CUBER AIR COOLED EXISTING 240V 1 5.9 - - 3/8" EXISTING TO BE RELOCATED " A22B 2 SYRUP RACK PLASTICS & PRODUCTS #SWST -9BP FOR CONDIMENT SENIOR & REGULAR OPTION 500L8 ICE STORAGE BIN EXISTING 3/4" EXISTING TO BE RELOCATED A22C 1 JAVA JACKET HOLDER PLASTICS & PRODUCTS #JJBP -12 FOR CONDIMENT SENIOR & F ICE BAG HOLDER SCOTSMAN #BGS10 A49 4 TRASH RECEPTACLE (BELOW COUNTER) IMPRESSIONS /SHOPCO 19 GALLON(14x14x24) PROVIDED BY IMPRESSIONS CASE OF 1000 BAGS SCOTSMAN #KBAG A50 2 NAPKIN HOLDER WASSERSTROM #H2000XC 180' OF TAPE SCOTSMAN #KTAPE A51 1 COFFEE TIMER PRINCE CASTLE #740 -T12PM 120V UNIT WITH CORD & NEMA 5-15 PLUG 1 LOT TAPE SEALER SCOTSMAN #KSEALER CASHIER FOUNTAIN B1B B2A 1 1 FROZEN BEVERAGE DISPENSER FOUNTAIN ICE MAKER (CUBED) ICEE MANITOWOC FBD #564D (4) FLAVOR #SY -1074C 208V 120V 1 19.0 2.5 3/8" 1/2" 1/2" E.C. TO PROVIDE NEMA #L6-30R RECEPT. EXISTING TO REMAIN PRE- CHARGED REGRIGERANT TUBE KIT (25') SCOTSMAN #RTE25 G6C 1 ICE MAKER REMOTE CONDENSING UNIT SCOTSMAN #ERC201 -32A - 240V 1 2.6 - - 1 W/ AUTOMATIC CLEANING SYSTEM MANITOWOC #AUCS 120V 1 G7 1 MOP SINK WASSERSTROM FIAT #MSB 2424 1/2" 1/2" 3" W/ #830 M FAUCET B2B 1 FOUNTAIN ICE MAKER (CRUSHED) SCOTSMAN #NME954RLS -1A 120V 1 15 1/2" 3/4" EXISTING TO REMAIN G8 1 WATER HEATER EXISTING EXISTING TO BE RELOCATED B2C 1 ICE MAKER REMOTE CONDENSING UNIT MANITOWOC #CVD -1085 240V 1 12.5 EXISTING TO REMAIN G9B 1 3 POSMON SINK W/ 18" BOWLS & (2) DRAINBOARD (90 "x30 -1/2 ") WASSERSTROM OR APPROVED EQUAL CUSTOM 2" NEW W/ LEVER DRAIN B2D 1 ' 20' LINE KIT MANITOWOC #RT- 20- R -404A EXISTING TO REMAIN B2E 1 ICE MAKER REMOTE CONDENSING UNIT SCOTSMAN #NME954RHS -A /C 240V 1 6.0 1/15 EXISTING TO REMAIN G9E 1 PRE -RINSE FAUCET WASSERSTROM FISHER #2210 1/2" 1/2 " W/ #2910 -12 ADD -ON- FAUCET Na DATE REVISION DESCRIPTION B2F 1 20' LINE KIT MANITOWOC #RT- 20- R -404A EXISTING TO REMAIN G10 2 BAG -IN -BOX MANITOWOC #5026343 (20 HEAD) / T \ 05.26.09 PERMIT REVIEW - BP B3A 1 FOUNTAIN CUP AND LID DISPENSER (LEFT) IMPRESSIONS #BP- PR -FOO -VCD -L EXISTING TO REMAIN G10A 1 WATER BOOSTER MANITOWOC #5025343 120V 1 5.6 0.672 - UNIT WITH CORD & NEMA 5 -15 PLUG /1\ 06,05.09 ISSUED FOR PERMIT - CITY B3B 1 FOUNTAIN CUP AND LID DISPENSER (RIGHT) IMPRESSIONS #BP- PR -FOO -VCD -R EXISTING TO REMAIN G11 1 WATER PURIFICATION SYSTEM EVERPURE #EV9437 -10 3/4" EXISTING TO REMAIN A 06 23 09 SIGN PERMIT REVIEW - CITY B6 1 FOUNTAIN CABINETRY IMPRESSIONS /SHOPCO MULTIPLE #'S - SEE CUT SHEETS EXISTING TO REMAIN G12 NOT USED A B7B 1 GRAPHIC DISPLAY BOARD - NON- ILLUMINATED DURA COLOR 96 "x45 -1/2" NEW G16A 2 HAND SINK WASSERSTROM OR APPROVED EQUAL EAGLE #CDI- 10 -14 -9 1/2 -1 #302004 1/2" 1/2" 2" NEW 5 B8 2 FCB LID /STRAW DISPENSER ICEE #788828 EXISTING TO REMAIN G21B 1 REACH -IN REFRIGERATOR TRADEMARK/TRAULSEN PRODUCTS #G30010 115V UNIT WITH CORD & NEMA 5 -15P : PLUG 6 ^� B9 2 CABINET TRASH RECEPTACLE IMPRESSIONS /SHOPCO INCLUDED IN FTN EXISTING TO REMAIN G21C 1 REACH -IN 3 -DOOR FREEZER TRADEMARK/TRAULSEN PRODUCTS #G31310 208V UNIT WITH CORD & NEMA 14 -20 PLUG B12 1 20 -VALVE ICE /BEVERAGE DISPENSER SERVEND /MANITOWOC #MDH- 402 -20 IC 20PB QT/ KITS Q1 /SL3 /CL5 120V 1/2" 3/4" EXISTING TO REMAIN G22 1 OVEN HOOD CAPTIVE AIRE #BP -2292 120V 1 15 - 0.33 CONTROL PANEL FURNISHED BY CAPTIVE AIRE A B13C 1 42" FCB CART IMPRESSIONS /SHOPCO #BP- FOO -FCB42 ON CASTERS G34 G54 1 2 MOP RACK CARBONATOR WASSERSTROM MANITOWOC RUBBERMAID #1992 120V 1 7.5 0.90 - 3/8" UNIT WITH CORD & NEMA 5 -15 PLUG . / B14C C1 1 1 FCB GRAPHIC FOR 42" CART - NON - ILLUMINATED CASHIER CABINET W/ IMPULSE SHELVING - 3' -0" DURA COLOR IMPRESSIONS / SHOPCO 41 "x45 -1/2" NEW G55A 2 4- BARREL FCB BAG N BOX /INSTALL KIT ICEE FBD #12- 2474 -0005 A C1A 2 CASHIER CABINET W/ IMPULSE SHELVING - 2' -0" IMPRESSIONS / SHOPCO G55C 2 4- BARREL BUCK N BOOST TRANSFORMER ICEE FBD #14- 2089 -0001 » C2 2 CASH REGISTERS /POS RADIANT STANDARD 120V 1 15 UNIT WITH CORD & NEMA 5- G56 1 ECO LAB SYSTEM 12 C3 2 INTERCOM TO FUEL POSITIONS 3M #D- l20VPART # 78- 6911- 4796 -7 SERIAL # 2470011634, 78- 8117- 3900 -8. w/4 station card 120V EXISTING TO REMAIN TG1 1 MICROWAVE OVEN SHARP OR APPROVED EQUAL R -21 FV 120V 1 15 1.68 NEW SEAL: J \O A• s TG2 1 NACHO RACK GEHL ARCO "NACHO" RACK C4 3 UNDER- COUNTER CIGARETTE DRAWER IMPRESSIONS /SHOPCO #BP- S00- CIGCPU34A/TBD EXISTING TO REMAIN TG2A 2 UNDERCOUNTER NACHO RACK SHOPCO t C5 1 SAFE - CASH VALIDATOR NKL #V2C CONTROLLER AUTOBANK 120V 1 15 UNIT WITH CORD & NEMA 5-15 PLUG TG3A 1 FOOD WARMER HATCO #LFST -41 120/2404 1 14.6 UNIT WITH CORD & NEMA 14-20 PLUG ` ' C5A 1 SAFE - COIN DROP NKL #D8C AUTOBANK 120V 1 15 UNIT WITH CORD & NEMA 5-15 PLUG TG4 1 FREESTANDING DELI CASE MASTER -BILT VERTICAL OPEN DISPLAY #QMVM 36 (COLOR: BLACK) 120/2081 1 10 2.08 PIPE TO DRAIN UNDER FOUNTAIN .. t r e: o - Z C5B 1 KEYPAD NKL #EPR TG5 1 6' PREP TABLE WASSERSTROM - METAL MASTERS #T3696SBC NEW C5D 1 PRINTER NKL #OM -100 120V 1 15 UNIT WITH CORD & NEMA 5-15 PLUG TG6 1 BUN TOASTER PRINCE CASTLE #197 120V 1 15 UNIT WITH CORD & NEMA 5 -15 PLUG -0 39913 � 'FS,S F G / S T ER �" G\ � C,\ C6A 1 LOTTO TERMINAL STATE LOTTERY COMMISSION 120V 1 UNIT WITH CORD & NEMA 5- TG7 1 CONVECTION OVEN DELUXE EQUIPMENT #HSM -6 -6 120/2404 1 39.5 8.22 UNIT WITH CORD & NEMA 14 -20 PLUG > C7 C7 1 TANK MONITOR EQUIPMENT VEEDEROOT VR -TLS 350 120V 1 EXISTING TO REMAIN TG7A 1 OVEN TABLE WASSERSTROM #0690 -25028 ON CASTERS L .\\ C9 1 LOT 8' FREE STANDING CIGARETTE WINDOW RACK IMPRESSIONS /SHOPCO MULTIPLE #'S - SEE CUT SHEETS TG8 1 CHIU AND CHEESE DISPENSER GEHL'S DUAL HOT TOP 120V 1 13 0.20 UNIT WITH CORD & NEMA 5-15 PLUG C10 1 LOT SMOKELESS TOBACCO BACK BAR RACKING AMERICAN DISPLAY /PHILIP MORRIS VENDOR TG10B 1 REFRIGERATED CONDIMENT COUNTERTOP WASSERSTROM (24X34) CUSTOM 120V 1 15.1 1.82 1/4 90 "x42" SELF- CONTAINED CONFIDENTIALITY STATEMENT: Cl 1 1 LOT CASHIER COUNTER IMPRESSIONS / SHOPCO MULTIPLE #'S - SEE CUT SHEETS EXISTING TO BE MODIFIED TG11 1 CONDIMENT DISPENSER WASSERSTROM #07721 THE RECIPIENT of THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. ONLY RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL ALLIANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT GLOBAL ALLIANCE EITHER UPON COMPLETION OFALSSETO INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL ALLIANCE, WHICHEVER COMES FIRST. C12 1 LOT CIGARETTE BACK BAR RACKING AMERICAN DISPLAY VENDOR TG15 1 TO GO BOX HOLDER CALIFORNIA QUALITY PLASTICS 1 LOT 2' TOP SIGN LARGE AMERICAN DISPLAY VENDOR TG14 1 3' DELI CASE HANGING FRUIT BASKET WASSERSTROM #BSK1W836 ATTACHED TO #TG4 1 LOT 2' WATERFALL SHELVES PHILIP MORRIS VENDOR TG16 1 UTENSIL HOLDER CALIFORNIA QUALITY PLASTICS 1 LOT 2' 4 SHELF PACK MODULESPACK SHELVES PHILIP MORRIS VENDOR TG17 1 LOT TO GO CABINETRY IMPRESSIONS /SHOPCO 1 LOT 2' TOBACCO SHELF PHILIP MORRIS VENDOR TG19 2 OVEN RACK DELUXE EQUIPMENT #APRE2018 -3 /KDA 1 LOT ACCESSORIES KIT AMERICAN DISPLAY /PHILIP MORRIS VENDOR TG33 1 TRASH RECEPTICLE AND TRAY HOLDER IDL DEVELOPMENT INFORMATION: 2009 RETROFIT C13 1 LOTTO FORM HOLDER LSI #385174 TG35D 1 FREE STANDING BAKERY CASE HUSSMAN DCA244262 C14 1 "WE'VE GOT YOUR BRAND" DECAL LSI #248507 BACKCOURT L &M - - C15 1 UNDERCOUNTER SCRATCH TICKET DISPENSER IMPRESSIONS / SHOPCO G17 4 SHELVING EXISTING C18B 1 ICE CREAM NOVELTY CASE (BEN & JERRY's) EXISTING 120V 1 15 EXISTING TO BE RELOCATED G17A 1 SHELVING EXISTING C20 1 LOT CIGARETTE BACK BAR STORAGE CABINETS AMERICAN DISPLAY VENDOR BULK GONDOLA SHOPCO C21 1 CIGARETTE BACK BAR MILLWORK VALANCE IMPRESSIONS /SHOPCO MULTIPLE #'S - SEE CUT SHEETS C23 1 LOTTO SHROUD LSI #701190 - REVIEWED FO14 SITE ADDRESS: 58 00 SOUTHCENTER BLVD. @I-5 TUKWILA, WASHINGTON C24 1 MEAT SNACK RACK SHOPCO D1 14 WALK -IN COOLER GLASS DOORS ASSEMBLY DISPLAY EXISTING TO REMAIN CODE COMPLIANCE APPRovED JUL D2A 14 WALK -IN COOLER 30 "X36" DEEP SLIDE -TRAC SHELVING EXISTING TO REMAIN D2C 1 COOLER SHELF TAG MOULDING STRIPS EXISTING TO REMAIN D6 2 COOLER SHELVING SYSTEM EXISTING TO REMAIN 1 7 2669 FAC 83098 D7 3 PLASTIC STORAGE PLATFORMS EXISTING TO REMAIN D10 4 WALK -IN COOLER EVAPORATOR EXISTING TO REMAIN Of TU * . DESIGNED BY ALLIANCE Z &DM: D10A 2 WALK -IN COOLER CONDENSING UNIT EXISTING TO REMAIN r' a I CHECKED BY BP REPM: DRAWN BY: ALLIANCE PM: VERSION: - PROJECT NO 1975.75 DRAWING 11TLE: EQUIPMENT SCHEDULE \ , l I I } I [ ! I I r t . NOTE: . IV R=C7 TUKVVILA 8 gut IH THIS PLAN, AS SHOWN, HAS BEEN APPROVED BY BP MARKETING MANAGEMENT ON APRIL 21, 2009. ANY DEVIATION TO THIS PLAN NEEDS TO BE APPROVED THROUGH NANCY KNOTT, FORMAT DEVELOPMENT MANAGER, BP RETAIL MARKETING AND INCORPORATED INTO THE PERMIT DOCUMENTS. CONTACT FRANCHISEE FOR MORE DETAILS. y l s. ,h a CITY OF JUL (3 SHEET NO PERMITCENTER Q�N1! bp I f s z r Ai iiiih, 1 Or ARCO BP WEST COAST PRODUCTS, LLC iin G, S 444 0 - "T y ,, , <T �NG ENG�N� 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION A ELECTRICAL ROUGH —IN LOCATION +12" A E.C. ELECTRICAL CONTRACTOR A A A A \ A A il 12 SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL AWANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN AU. MATERIALS TO GLOBAL AWANCE ETHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I-5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CG AWANCE Z&DM: CHECKED BY: RH BP REPM: DRAWN BY: AWANCE PM: VERSION: PROJECT NO: 1975.75 DRAWING TITLE: ELECTRICAL ROUGH -IN PLAN SHEET NO: E.111 EXISTING OFFICE AL±5.9! _ WA BOOSTER ( f STUB —UP 1" CONDUIT +6" FUTURE ITEMS ON COFFEE BAR BCFIE HOSTESS TG10B EIAL±54" COFFEE TIME SWEET CAKES EXISTING FORAGE RECEPT AT 241_ CONDIMENT REF R 2' PUBLIC. E T. AT +12" C6A IN CABINET BASE �—�� LOTTO TERMINAL rti �� L RECEPT AT 24" FOOD ITA RECEPT. AT +12" IN CABINET BASE C5D INTERCOM,SAFE P 'INTER __.... SYSTEM EX. ECEPT. AT ±12" IN CABINET BASE LOTTO TERMINAL NEW UNISEX REST ROOM FFar0 /AL±24" HEESE DISP 3' C.AI'IDY PROMO 1 2dr FREEZER PRIMARY SODA H CIGAR ETTES ow (I:>elow) 3dr REFRIGERATOR EXISTING SALES AREA STUB UP (5) -1" & (1) -3/4" CONDUITS +6" I FOR RECEPT'S IN TRANSACTION COUNTER _ —..... Illy "!! :'. S. AT +12" ---- - - - - -- N B ET BASE c ASH EGISTERS/POS RECEPT. AT +12" i IN CABINET BASE CAS FIkr SYSTEM r 3' JERKY 2' NBA BULK 2 I: 1V E BEER DISPLAY AUTO XISTING REFAB OOLER ECE'LT_ALf41i" __ —__ -- COMPUTER SYSTEM ECEE1_6L3-.47_ __ - -- CARBONATOR EC EEL 6L-..2.4" __ ____ __ ICED LATTE RECEPZAI±24" _ DUAL SOFT HEAT BREWER cEeti_AL+- - - - -- cap DOUBLE SOFT HEAT STAND CEO •ECEELALt24."___ — _- LATTE STEAMER RECEPT'S AT +18" __ _ CAPPUCCINO MAKER 0 RECEPT. AT +28" FROZEN _ BEVERAGE DISPEN REACH —IN F R REACH —IN /FREEZER EXISTING COVERED TRASH ENCLOSURE EXISTING STORAGE CONTAINER I — __— __ — - _ BECFPr— 1 " C18A ICE CREAM NOVELTY CASE ELECTRICAL ROUGH -IN PLAN 0 x x C GENERAL NOTES A. ALL DIMENSIONS FOR UTILITIES LOCATED IN SLAB ARE RUNNING DIMENSIONS, TO BE FROM INSIDE FACE OF EXTERIOR WALL TO CENTER OF ROUGH —IN. ALL OTHER DIMENSIONS ARE FROM FACE OF STUD TO CENTER OF ROUGH —INS. B. ALL SERVICES SHOWN WITH SYMBOLS CENTERED ON FACE OF STUD WALL SHOULD BE BROUGHT TO THAT POINT CONCEALED IN WALL AND STUBBED OUT OF WALL CENTERED AT HEIGHT SHOWN. DO NOT STUB OUT OF FLOOR AND RUN EXPOSED UP FACE OF WALL UNLESS OTHERWISE NOTED. EXPIRES 10 -24 -2010 Date Signed: Jun 30, 2009 RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER 10555 Old PIc yW Sacramento, C/( - 9 ®� Phone: 6� V (91 Fax: 916 www.sacREt ■I RED Job No. 09217 EQUIPMENT ELECTRICAL LEGEND O CONDUIT STUB —UP (SEE PLAN FOR SIZE) ■ ELECTRICAL ROUGH —IN LOCATION +12" HEIGHT OF ROUGH —IN ABOBE FINISHED FLOOR E.C. ELECTRICAL CONTRACTOR EXISTING OFFICE AL±5.9! _ WA BOOSTER ( f STUB —UP 1" CONDUIT +6" FUTURE ITEMS ON COFFEE BAR BCFIE HOSTESS TG10B EIAL±54" COFFEE TIME SWEET CAKES EXISTING FORAGE RECEPT AT 241_ CONDIMENT REF R 2' PUBLIC. E T. AT +12" C6A IN CABINET BASE �—�� LOTTO TERMINAL rti �� L RECEPT AT 24" FOOD ITA RECEPT. AT +12" IN CABINET BASE C5D INTERCOM,SAFE P 'INTER __.... SYSTEM EX. ECEPT. AT ±12" IN CABINET BASE LOTTO TERMINAL NEW UNISEX REST ROOM FFar0 /AL±24" HEESE DISP 3' C.AI'IDY PROMO 1 2dr FREEZER PRIMARY SODA H CIGAR ETTES ow (I:>elow) 3dr REFRIGERATOR EXISTING SALES AREA STUB UP (5) -1" & (1) -3/4" CONDUITS +6" I FOR RECEPT'S IN TRANSACTION COUNTER _ —..... Illy "!! :'. S. AT +12" ---- - - - - -- N B ET BASE c ASH EGISTERS/POS RECEPT. AT +12" i IN CABINET BASE CAS FIkr SYSTEM r 3' JERKY 2' NBA BULK 2 I: 1V E BEER DISPLAY AUTO XISTING REFAB OOLER ECE'LT_ALf41i" __ —__ -- COMPUTER SYSTEM ECEE1_6L3-.47_ __ - -- CARBONATOR EC EEL 6L-..2.4" __ ____ __ ICED LATTE RECEPZAI±24" _ DUAL SOFT HEAT BREWER cEeti_AL+- - - - -- cap DOUBLE SOFT HEAT STAND CEO •ECEELALt24."___ — _- LATTE STEAMER RECEPT'S AT +18" __ _ CAPPUCCINO MAKER 0 RECEPT. AT +28" FROZEN _ BEVERAGE DISPEN REACH —IN F R REACH —IN /FREEZER EXISTING COVERED TRASH ENCLOSURE EXISTING STORAGE CONTAINER I — __— __ — - _ BECFPr— 1 " C18A ICE CREAM NOVELTY CASE ELECTRICAL ROUGH -IN PLAN 0 x x C GENERAL NOTES A. ALL DIMENSIONS FOR UTILITIES LOCATED IN SLAB ARE RUNNING DIMENSIONS, TO BE FROM INSIDE FACE OF EXTERIOR WALL TO CENTER OF ROUGH —IN. ALL OTHER DIMENSIONS ARE FROM FACE OF STUD TO CENTER OF ROUGH —INS. B. ALL SERVICES SHOWN WITH SYMBOLS CENTERED ON FACE OF STUD WALL SHOULD BE BROUGHT TO THAT POINT CONCEALED IN WALL AND STUBBED OUT OF WALL CENTERED AT HEIGHT SHOWN. DO NOT STUB OUT OF FLOOR AND RUN EXPOSED UP FACE OF WALL UNLESS OTHERWISE NOTED. EXPIRES 10 -24 -2010 Date Signed: Jun 30, 2009 RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER 10555 Old PIc yW Sacramento, C/( - 9 ®� Phone: 6� V (91 Fax: 916 www.sacREt ■I RED Job No. 09217 1:1 AA• 1 Or ARCO BP WEST COAST PRODUCTS, LLC i tt"G4 VV DRAWING LEGEND 0 2 SYMBOL DESCRIPTION KENT, WA 98032 IG ISOLATED GROUND CIVIL ENGINEERING, LAND PLANNING, FJ a JUNCTION BOX DATE REVISION DESCRIPTION 0 SIMPLEX RECEPTACLE A DUPLEX RECEPTACLE QUAD RECEPTACLE A 208V I? OR 208V 3? RECEPTACLE A NON -FUSED DISCONNECT SWITCH A DOUBLE GANG J -BOX WITH SINGLE GANG PLASTER RING TO BE PROVIDED BY AND INSTALLED BY ELECTRICAL CONTRACTOR PROVIDE SIEMON CT4 -FP -20 FACE PLATE W/ 2 SIEMON CT -AK -20 INSERTS. SEE RJ -45 RECEPTACLE WIRING DIAGRAM DETAIL FOR PROPER WIRING ORDER ELECTRICIAN TO NUMBER EACI -I CONNECTION AS SHOWN TO COORDINATE WITH PATCH PANEL NUMBERS. WRITE -ON LABEL UNDER CLEAR PLASTIC COVER INDICATING PATCH PANEL IDENTIFIER PROVIDE PRINTED INSERTS FOR ALL LABELS (HANDWRITTEN NOT ACCEPTABLE). A DOUBLE GANG TELEPHONE OUTLET WIN SINGLE GANG PLASTER RING TO BE PROVIDED BY AND INSTALLED BY ELECTRICAL CONTRACTOR PROVIDE SIEMON CT4 -FP -20 FACE PLATE W/ 2 SIEMON CT -AK -20 INSERTS. SEE RJ -45 RECEPTACLE WIRING DIAGRAM DETAIL FOR PROPER WIRING ORDER. ELECTRICIAN TO NUMBER EACH CONNECTION AS SHOWN TO COORDINATE WITH PATCH PANEL NUMBERS. WRITE -ON LABEL UNDER CLEAR PLASTIC COVER INDICATING PATCH PANEL IDENTIFIER PROVIDE PRINTED INSERTS FOR ALL LABELS (HANDWRITTEN NOT ACCEPTABLE). A s SINGLE POLE TOGGLE SWITCH, 20 AMPERE RATED, MOUNTED 48" AF.F. UNLESS NOTED OTHERWISE. SUBSCRIPT: "a" - LOWER CASE LETTER INDICATES SWITCH CONTROL. "P" - DENOTES LIGHTED HANDLE TOGGLE SWITCH, LAMP IN SWITCH SHALL LIGHT WHEN EQUIPMENT IS OPERATING: A 1:1 AA• 1 Or ARCO BP WEST COAST PRODUCTS, LLC i tt"G4 VV _41 .... C, 0- ..) 1,,.., 0 2 : 4z , G E 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION 0 A A A A A A A A A SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL AWANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR NHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL AWANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @I-5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CG AWANCE Z &DM: CHECKED BY: RH BP REPM: DRAWN BY: AWANCE PM: VERSION: - PROJECT NO: _ 1975.75 DRAWING TITLE: ELECTRICAL FLOOR PLAN SHEET NO: Y 1 E1112 MDP PANEL 'X' °- SERVICE = GROUND SEE SINGLE LINE RISER DIAGRAM I N I METALLIC J. BOX ISOLATED GROUND TREATMENT DIAGRAM SCALE: NO SCALE EXISTING OFFICE EXISTING COVERED TRASH ENCLOSURE BO-1E (E) PANEL 'A' C -1 A- 20,22 4-3I EXISTING STORAGE PUBLIC. ATM l E 15T R NL B 2,4 5-5 % NOTE: ALL Cbf\IDb'f5 PASSING HRa1 GH NE WA► 4.5, OR FLOORS OF THE COOLER/FREEZER UNIT 1-} - SEALED PER ARTICLE 300 -1 NEW UNISEX REST ROOM ICE CR'EA 4 I USE (E) CKT'S 2d FREEZER 3' CANDY PE1MAT SODA BULK 8° CIGARETTES Q OTP (below) Edr REFRIGERATOR EXISTING SALES PRa O T I AREA E :KY CASH BEER DISPLAY XISTING REFAB OGLER O A - 1,3 U U- G -2 POWER CONDITIONER LOOP ISOLATED #10 GROUND THRU PNL PANEL 'G' UNBROKEN TO PNL 'MDP' PANEL 'X' ELECTRICAL PLAN SCALE: 1/4 "=1'- CONDITIONED POWER WIRING NOTES: AO PROVIDE 30/1P C/B IN POWER PANEL FOR POWER CONDITIONER PANEL. CONNECT TO SAME PHASE AS DISPENSER POWER, O THE GROUNDING CONDUCTOR TO THE POWER CONDITIONER SHALL BE CONNECTED TO A GROUND BUS IN THE MDP. © CIRCUITING FROM THE POWER CONDITIONER TO THE ISOLATED GROUND PANEL, SHALL BE IN METALLIC CONDUIT WITH SEPARATE NEUTRAL, PHASE WIRE, AND BONDING WIRE. GROUND BUS ELECTRICALLY ISOLATED FROM PANEL ENCLOSURE E.C. TO PROVIDE AND INSTALL POWER CONDITIONER TO SERVICE ISOLATED GROUND PANEL, UNIT SHALL BE RATED AT 3000VA, (POWERVAR #ABC3030 -11) EO CIRCUITING FROM THE ISOLATED GROUND PANEL TO THE ISOLATED GROUND RECEPTACLES SHALL BE IN METALLIC RACEWAY (COMPLETELY SEPARATED FROM OTHER UNCONDITIONED POWER WIRING INCLUDING THE FEED TO THE POWER CONDITIONER - LE. SEPARATE RACEWAYS, WIRE WAYS AND TROUGHS) WITH A SEPARATE NEUTRAL, PHASE WIRE, BOUNDING WIRE AND AN ISOLATED GROUND WIRE, THE BONDING WIRE SHALL BE SHARED WITH MULTIPLE ISOLATED GROUND CIRCUITS, O THE ISOLATED GROUND RECEPTACLES SHALL BEI DUPLEX - HUBBELL IG 5362 SIMPLEX - HUBBELL IG 5261 O ALL ISOLATED GROUND WIRING TO RECEPTACLES SHALL BE AWG #10 WITH A PIGTAIL SPLICE TO AWG #12 WITHIN JUNCTION BOX TO CONNECT #12 TO RECEPTACLE, OH ALL WIRING SHALL BE MINIMUM AWG #12 COPPER EXCEPT FOR ISOLATED GROUND WIRING WHICH SHALL BE AWG #10 COPPER MINIMUM. 0 FOLLOW POWER CONDITIONER MANUFACTURER'S INSTRUCTION MANUAL FOR PROPER INSTALLATION, INSTALL ALL JUMPERS NECESSARY FOR 120 VOLT INPUT, OJ ALL RECEPTACLES SHALL BE LABELED ON THE FINISH PLATE WITH DYNAMO MARKER TAPE. LABEL SHALL INDICATE PANEL AND CIRCUIT NUMBER, EXISTING STORAGE CONTAINER E KEYED NOTES: CONTRACTOR TO INSTALL NEW EMERGENCY SHUTDOWN SWITCH (E.S.O.) AT SALES COUNTER (INCLUDING RESET) AND ALSO REPLACE EXISTING ONE AT BUILDING EXTERIOR. CONTRACTOR TO VERIFY THAT EMERGENCY SHUTDOWN SWITCHES ARE WIRED TO SHUT DOWN BOTH TURBINES AND DISPENSERS. REWIRE TO DISPENSER MANAGER IF NOT EXISTING. ESO SWITCH SHALL BE D 1ST INCLY LABELED AS "EMERGENCY FUEL SHUTDOWN DEVICE.:' SIGNS SHALL BE PROVIDED. IN APPROVED LOCATIONS 45 DETERMINED BY THE FIRE INSPECTOR. ELECTRICAL NOTES Fr> "EXISTING AREA TO REMAIN AS IS. E.C. TO ROUTE (2) "12 AND (I) "12 GROUND IN 1/2" CONDUIT TO AVAILABLE 120V, 20A BREAKER IN ELECTRICAL PANEL. E.C. TO ROUTE (3) "12 AND (1) *12 GROUND IN 1/2 CONDUIT TO AVAILABLE 120V, 20.4 BREAKER IN ELECTRICAL PANEL. F5 E.C. TO ROUTE (4) 0 10 AND (1) *12 GROUND IN 3/4" CONDUIT TO AVAILABLE 208V, 3P 30A BREAKER IN ELECTRICAL PANEL. E.C. TO ROUTE (3) *S AND (1) *10 GROUND IN 3/4" CONDUIT TO AVAILABLE 208V, IP 40.4 BREAKER IN ELECTRICAL PANEL. E.C. TO ROUTE (3) *8 AND (1) *10 GROUND IN 3/4" CONDUIT TO AVAILABLE 208V, 1P 50A BREAKER IN ELECTRICAL PANEL. EXISTING PANEL SCI- IEDULE LABELING HAS NOT BEEN VERIFIED. PLANS ARE BASED ON THE ACCURACY OF THE EXISTING PANEL LABELING. CONTRACTOR 51-1OULD VERIFY ALL CIRCUITS. 2 . VERIFY PEAK HISTORICAL LOADING WIN UTILITY COMPANY. 3. VERIFY NEUJ LOADS FALL. WITHIN PANEL CAPACITY. 4. BALANCE ALL PANEL LOADS AT COMPLETION OF WORK 5. CONTRACTOR SHALL PROVIDE TYPEWRITTEN LABELS FOR COMPLETE ELECTRICAL PANELS FOLLOWING COMPLETION OF WORK. PROVIDE BP WIN A COPY OF PANEL SCHEDULE FOR FUTURE MODIFICATION. 6. PROVIDE CEILING RECEPTACLES FOR BOTH SECURITY MONITORS. -I. UNDERGROUND CONDUIT MUST BE RIGID FOR FINAL 24 STUB - UPS AT COUNTERS TO PROTECT FROM DAMAGE. a EXTEND EXISTING CONDUITS FROM SALES COUNTER CONTACT BP ENGINEER IF ADDITIONAL CONDUITS WILL NEED TO BE ADDED. 9. PROVIDE ISOLATED DEDICATED ELECTRICAL CIRCUIT AND PHONE LINE AT ATM REVISED LOCATION - FOLLOWING ELECTRICAL MOVE COORDINATE WIN ATM VENDO FOR NE RELOCATION OF THE ATM. 11. NOT USED. 14. NOT USED. 12 OPENING IN SLAB FOR ROUTING OF CONDUIT FOR CASHIER COUNTER REFER TO SHEET E,12 FOR CONDUIT SIZES. G.C. TO GROUT FINISHED FLOOR AFTER CIRCUIT INSTALLATION. E.C. TO ROUTE (3) *4 AND (1) *8 GROUND IN I CONDUIT TO AVAILABLE 208V, 1P 10A BREAKER IN ELECTRICAL PANEL. NOT PRESENT E.C. TO PROVIDE AND INSTALL PER DETAIL 01 -E2.0. 10> E.G. TO PROVIDE AND INSTALL CLASS 11 A" 5mA GROUND FAULT BREAKER IN PAN l CONTROL PANEL FOR HOOD EXHAUST FAN. CONTROL PANEL FURNISHED AND INSTALLED BY CAPTIVE AIRE. LOCATION OF PROPOSED POWER CONDITIONER E.C. TO COORDINATE LOCATION PRIOR TO INSTALLATION. Date Signed: Jun 30, 2009 10. MINIMIZE BENDS IN CONDUITS FOR NETWORK CABLING 12. COORDINATE NE RELOCATION OF NE SATELLITE MODEM AT NE SALES COUNTER AND RECONNECTION WITH HUGHES SATELLITE. CABLE FOR SATELLITE CONNECTION MAY NOT BE CUT AND SPLICED. i1 13. CONTRACTOR TO ASSIST IN RECONNECTION O INTERCOM AND ALL SALES COUNTER EQUIPMENT. 15. CONTRACTOR TO RELOCATE OVERHEAD ELECTRIC4 1 AND POLE FOR BREEZE COOLER (CI1A). 16. CONTRACTOR TO INSTALL ELECTRICAL FOR NEW ICE k CREAM NOVELTY CASE AS NOTED ON NE PLAN 11. CONTRACTOR SHALL INSTALL NEW ELECTRIC: L OU TLET AT SALES COUNTER FOR FOOD FORWARD PRO I M , 18. CONTRACTOR TO INSTALL RECESSED SOFFI `LIGHTING OVER ALL MERCHANDISED AREAS. FOOD R VICE" '"` �S AREAS MUST HAVE ADEQUATE SHATTER PROTECTION. 19. SALES REGISTERS/P05 SHALL BE UPGRADED TO �� "RETAILIX" SYSTEM WHEN AVAILIABLE. CONTACT 1 MORE INFORMATION. P` POR F9 E.C. TO ROUTE (2) *12 AND (I) 12 GROUND WIN (1) *12 ISOLATED GROUND IN 111 CONDUIT BACK TO 20A BREAKER IN POWER CONDITIONED PANEL. IF POWER COND E.C. TO ROUTE (2) *12 AND (1) *12 GROUND IN LIQUID TIGHT TO FIELD BOX AT BOTTOM OF MILLWORK FROM FIELD BOX E.C. TO ROUTE TO AVAILABLE 120V, 20.4 BREAKER IN ELECTRICAL PANEL. IF NO SPARE BREAKER PRESENT E.G. TO PROVIDE AND INSTALL BREAKER E.C. TO ROUTE (3) *12 AND (I) "12 GROUND IN LIQUID TIGHT TO FIELD BOX AT BOTTOM OF MILLWORK FROM FIELD BOX E.C. TO ROUTE TO AVAILABLE 120V, 20A BREAKER IN ELECTRICAL PANEL. IF NO SPARE BREAKER PRESENT E.C. TO PROVIDE AND INSTALL BREAKER RECEIVED CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER 10555 Old Sacramento, f" .' � �',,: �'�` . — l.h , Phone: (91 ' ±• AND Fax: (91 a • WWW.S.:: VA_ Job Job No. 09 g =AI bp Ak 11. IF ARCO BP WEST COAST PRODUCTS, LLC lir i %,1 ,.,iiii t -... I Ai , Illa ...,...,e1._ 0 'W ,./Fr ° 27Mc ";4 til e, v (,. 0 , %‘,‘• i'vt. ENG- 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251-6222 (425)251-8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES LIGHT FIXTURE SCHEDULE DATE REVISION DESCRIPTION SYMBOL MARK TYPE MOUNTING art MANUFACTURE AND CATALOG NUMBER LAMPING QTY VOLTS WATTS TYPE A\ A FLUORESCENT SURFACE , i 2x4 SURFACE PARABOLIC CUBE LIGHT FIXTURE MATCH EXISTING LSI FIXTURE 2 120 32 LAMPS- SYLVANIA #F032/835/XPS/EC BALLAST - SEE NOTE B C2 FLUORESCENT SURFACE ' i LOW LSI #WNA10 PROFILE WRAPAROUND 2 SS12 F UE 2 120 32 LAMPS- SYLVANIA #F032/835/XPS/EC BALLAST - SEE NOTE B Its 0 I C2 FLUORESCENT LAY-IN „ 't 1x2 LAY-IN, WALL WASH WITH SIDE MOUNTED LAMPS LSI #NWW217-SSO1ORPSX-LMP841-UE-OSR-SYL 2 120 17 F17 T8 milill BP REPM: DRAWN BY: • C4 FLUORESCENT LAY-IN 4 , '' 1x4 LAY-IN, WALL WASH WITH SIDE MOUNTED LAMPS LSI #NWW232-SSO1ORPSX-LM841-UE-OSR-SYL 2 120 32 LAMPS- SYLVANIA #FO32/835/XPS/EC BALLAST - SEE NOTE B milimilinc a W WALL WASH RECESSED _, ' 6' VERTICAL REFLECTOR DOWNLIGHT WITH A SEMI CLEAR SPECULAR FINISH LSI #206V-CFL-1-26T-UE-206VCL-LM2627 1 120 2 ' , GE COMPACT FLUORESCENT GE GENURA EL23/R25/SW a wi DOWNLIGHT RECESSED 4 SELF FLANGED, SINGLE REFLECTOR WITH A SPECULAR CLEAR FINISH LSI #206HCFL-1-26Q-UNIV-C27-206HL-LMP2627 1 120 26 <> 0 VAPOR/DOWNLIGHT SURFACE - VAPOR PROOF LIGHT FOR FREEZER/ COOLER LSI #VP12-1-42T-CFL-UE-LM4227 1 120 42 1 ' EM1 BATTERY BACK UP CEILING/ WALL - COMBO LED EXIT SIGN AND EMERGENCY LIGHT LSI #EMEX-1-R-W-120/277 2 6V 5,4 NOTES: THAT FLUORESCENT FIXTURE IS TO BE PROVIDED WITH A SELF DENOTES B. BALLAST SHALL BE QTP2X32T8/UNV PSX TC W/ UNIVERSAL VOLTAGE AND PROGRAM START, EM CONTAINED EMERGENCY BACKUP BATTERY TO POWER ONE LAMP FOR 90 MINUTES C. BALLAST SHALL BE QTP3X32T8/UNV PSX TC W UNIVERSAL VOLTAGE AND PROGRAM START. UPON LOSS OF AC POWER, LSI #EM132 D, ALL 32V T8 LAMPS TO HAVE CRI OF 3500K, =AI bp Ak 11. IF ARCO BP WEST COAST PRODUCTS, LLC lir i %,1 ,.,iiii t -... I Ai , Illa ...,...,e1._ 0 'W ,./Fr ° 27Mc ";4 til e, v (,. 0 , %‘,‘• i'vt. ENG- 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251-6222 (425)251-8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION /1\ A A\ A\ A A A A A SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL ALLIANCE. AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE. ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS m ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE UMITED PURPOSE FOR 1t1-IICH GLOBAL AWANCE HAS MADE Tim MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALUANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @ 1-5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CG AWANCE Z&DM: C HECKED BY: RH BP REPM: DRAWN BY: • AWANCE PM: VERSION: . - PROJECT NO: 1975.75 DRAINING TITLE: ELECTRICAL DEMO/LIGHTING FLOOR PLAN SHEET NO: i f il I li 3 EXISTING OFFICE SCALE: 11/4":1° EXISTING COVERED TRASH ENCLOSURE 40.4.Weitortlit, 4.**441*Vir.*V411 4 .0044.4. NV4- W*.s.44 4 *VIVA • TANK POI EL "A" MONITOR it I 1 BAC K R 00 EXISTING STORAGE ELECTRICAL DEMOLITION PLAN GENERAL NOTE: DISCONNECT AND REMOVE EXISTING OUTLETS FEEDING EQUIPMENIT BEING REMOVEIDRERIFY RE-USE OF OUTLETLITH-N00 EQUIFMEff TYPICAL --- fr — 1 11 1 1 I I 1 11 1 1 11 1 11 1 1 11 I II I 1 11 // / // /// / // 7 / NOTE: REFER TO SHEET Q.1.1 FOR EQUIPMENT SCHEDULE AND DESCRIPTION. EXISTING STORAGE CONTAINER px1STING JSALES AREA CASHIER IT111111111111 W111E11E11E1 I ,14,1 KR) kw-II X !STING REFAB 00 LER PRESCOL ITE AKTHLCE21E3 SCALE: 1/8"4-0 EXISTING COVERED TRASH ENCLOSURE EXISTING STORAGE DEMOLITION LIGHTING PLAN SCALE: 1/8'4-0" EXISTING COVERED TRASH ENCLOSURE (E) FIXTURE TO REMAIN, TYPICAL 3ACKIRO NEW LIGHTING PLAN — r 0 --" 41 11 ;10 1 ...xl X) (X) [ X) _ ) 14 iiiiiiiiii A 1 ,,,: ilit APE A... 44 7 IIVAEZIII AIWA r. „,imErarmo , , ,, iii . t ... arill iffimadialk , , , ( ga. la ffillell 11111 EN IN ,.., . ; STORAGE TAINER (XSTING STORAGE CONTAINER NUMBERED NOTES C2, TYPICAL CONNECT NEUJ LIGHTS TO EXISTING LIGHTING CIRCUIT. EXTEND EXISTING LIGHTING CIRCUIT TO NEW LIGHTS. INSTALL NEW SWITCHES TO CONTROL NEW LIGI-ITS. XIS TING 12 X)OLER XISTING 'REFAB OOLER C4, TYPICAL 1 EXPIRES 10-24-2010 Date Signed: Jun 30, 2009 RECEIVED CITY OF TUKWILA JUL d 2009 PERMIT CENTER E ES CONSULTANTS (E) PANEL B 120/240V. 1 Ph. 3W. 400 AMP BUS SURFACE OUNTED ISC DESCRIPTION KVA BKR CKT Ph. A Ph. B :.KT BKR KVA DESCRIPTION CONVECTION OVEN KVA 40/2 r CO 5.8 _ 5,8 N 20/2 1.7 t7 FOOD WARMER OVEN HOOD BUN TOASTER O O ▪ r- 20/1 20/1 �f) N- 2.4 6 20/1 0.6 (E) FREEZE 2.0 8 20/1 0.2 (E) OFFICE OMP (E) MENU BD 0 4 20/1 9 0.8 SEAL: 10 20/1 0.4 (E) FANS (E) BCK BLG LTG (E) FUEL SUB MAIN CO CO CO O V' Vt 20/1 60/2 11 13 4.9 1.2 12 20/15 0.6 (E) FRZR LT / (E) FAN (E) CNPY LT/ (E) OFF 14 20/1 0.6 (E) WINE C OLER 15 1,8 4.9 16 20/1 0.6 (E) MILK COOLER (E) COUNTER REC (E) COUNTER REC d d O Co 20/1 20/1 17 19 0.4 3.8 18 1 20/1 SPARE 1.0 20 15/2 0.6 0.6 (E) ICE MA ER SPARE SPACE (E) ILLUMINATED FASCIA (E) ILLUMINATED FASCIA (E) CLR COMPRESS (E) SUB MAIN 20/1 21 23 0.6 3.8 22 1.0 24 20/2 1.0 1.0 DELI COOL R (E) SITE CONTROL MICROWAVE (E) AIR WATER / (E) ATM O r O 20/1 20/1 20/20 25 27 29 1.2 1.4 2.6 26 2.7 28 20/2 1.0 1.0 (E) FREEZER 2: 30 (E) HOT WTR TANK Co O or- 30/2 31 33 2.0 2.0 32 20/2 1.0 1.0 (E) FREEZER 20/1 31 33 34 (E) HEAT PUMP (E) HEAT PUMP CD O O O CO CO CO CO 50/2 50/2 35 (E) COUNTER REC 7.0 36 60/2 4.0 4.0 (E) FURNACE ICED LATE LATTE STEAMER 37 39 7.0 35 37 38 7,0 40 60/2 4.0 4.0 (E) FURNAC 41 7.0 0.6 0.6 42 SUBTOTAL: 33.5 34.6 39 CONNECTED LOAD 68.1 KVA 4• MAIN LUGS ONLY SUBTOTAL: 25% LIGHTING LOAD KVA 25% LARGEST MOTOR KVA CONNECTED LOAD 4 .3 KVA 1st 10,0 KVA RECEPTACLE LOA © 100% PLUS REMAINDER @ 50% KVA MAIN LUGS ONLY 25% LIGHTING LOAD KVA 25% LARGEST MOTOR KVA TOTAL LOAD 6 .1 KVA / 0,240 FACTO 284 AMPS (E) PANEL A 2)0 120/240V. 1 Ph. 3W. AMP BUS ISC SURFACE MOUNTED DESCRIPTION DESCRIPTION KVA CKT BKR CKT Ph. A Ph. B CKT DESCRIPTION BKR KVA DESCRIPTION 20/1 FCB DISPENSER N N 2 ' 40/2 1 2.6 OFFICE COMPUTER REACH -IN FREEZER CHILI /CHEESE DISP 20/2 0.4 0.4 (E) ICE CUBER 3 4 2.6 0.8 (E) PUMP LIGHTS • • O 20/2 N- 1.4 20/1 1.4 20 /20 0.6 (E) CANOPY LIGHTS SEAL: 1.4 THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL AWANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE, ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE NE MATERIALS ONLY FOR THE UNITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN AU. MATERIALS TO GLOBAL AWANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE, WHICHEVER COMES FIRST, 20/1 0.6 (E) CANOPY CVTLR SPACE / SPACE ADDRESS: SOUTHCENTER BLVD. @1-5 TUKWILA, WASHINGTON 20/20 9 0.6 CHECKED BY: RH 1 20/20 0.6 (E) CNPY LT/ (E) OFF SPACE / (E) STORE LT (E) STORE LT/ SPACE n . O 20/20 20/20 11 13 1.4 1,8 1 20/2 0.8 0.8 (E) ID SIGN 1 COFFEE BREWER I a 40/2 15 17 3.8 3.4 1 20/1 0.4 (E) POP SIGN 1 20/20 0.8 (E) POP / (E) VIDEO COFFEE BREWER (E) ILLUMINATED FASCIA (E) ILLUMINATED FASCIA (E) CLR COMPRESS (E) SUB MAIN ; ; 1 I • . 20/1 20/1 30/2 100/2 19 21 23 3.8 3.8 2 40/2 3.0 3.0 2 ' 2.6 2a 20/20 0.6 (E) ICE CRM FREEZER 25 27 2.6 2. 20/20 0.6 (E) ICE CRM FREEZER 3.5 2: SPACE 29 3.5 3' SPACE SPACE COFFEE COUNTER 0, 20/1 31 33 0.8 0.4 3 20/20 0.4 (E) COUNTER REC 20/1 0.4 (E) COUNTER REC ICED LATE LATTE STEAMER 20/1 20/1 35 37 2.4 1.5 3. 20/1 0.4 (E) COUNTER REC 3: 20/2 0.6 0.6 (E) HOZHIZAKI ICE (E) CLR LTS / (E) HTR 0.: 20/20 39 1.4 4• SUBTOTAL: 22.9 1 22.4 CONNECTED LOAD 4 .3 KVA MAIN LUGS ONLY 25% LIGHTING LOAD KVA 25% LARGEST MOTOR KVA 1st10,0 KVA RECEPTACLE LOA' @ 100% PLUS REMAINDER @ 50% KVA TOTAL LOAD 4'.3 KVA / 0.240 FACTC 189 AMPS 120/40V. NEW PANEL C 100 AMP BUS 1 Ph. 3W. SURFACE ISC MOUNTED DESCRIPTION KVA BKR CKT Ph. A Ph. B CKT BKR KVA DESCRIPTION WATER BOOSTER 0.6 20/1 1 1.4 A 2 20/1 0.8 OFFICE COMPUTER REACH -IN FREEZER CHILI /CHEESE DISP 0.8 0.8 1.2 20/2 20/1 3 1.6 4 20/1 0.8 REACH -IN IREF'R LO 2.2 6 20/1 1.4 CONDIMENT REF'R 1.2 8 SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL AWANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE, ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE NE MATERIALS ONLY FOR THE UNITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN AU. MATERIALS TO GLOBAL AWANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE, WHICHEVER COMES FIRST, DEVELOPMENT INFORMA11ON: 2009 RETROFIT BACKCOURT RANCH STYLE 9 ADDRESS: SOUTHCENTER BLVD. @1-5 TUKWILA, WASHINGTON FAC 83098 10 AWANCE Z &DM: CHECKED BY: RH BP REPM: DRAWN BY: AWANCE PM: VERSION: _ 11 13 DRAWING TITLE: ELECTRICAL SCHEDULES & DIAGRAMS SHEET 12 .4 14 15 17 16 18 19 20 SUBTOTAL: 3.6 2.8 CONNECTED LOAD 6.4 KVA MAIN LUGS ONLY 25% LIGHTING LOAD KVA 25% LARGEST MOTOR KVA 1st10.0 KVA RECEPTACLE LOAD @ 100% PLUS REMAINDER @ 50% KVA TOTAL LOAD 6.4 KVA / 0.240 FACTC 27 AMPS Site PC Veritene V900 (EPS) Retalix BOS Allied box APG Cash Drawer SureP0S 500 APG Cash Drawe Epson Printer Distributed display Effective DMZ SATELLITE DISH ON ROOF POS DIAGRAM SCALE! N,T,S, PIC unit Alternate Telecom s Solution Network switch (FS116). Forecourt devices ® -000 000 o OLIO ATM ATM AREA SurePOS 500 Verrone OMNt7O0 pinpad Distributed display POS 2 PIC UNIT TLS GENERAL NOTES PIC UNIT ALLIED BOX TANK LEVEL SENSOR CAT 5 LAN CABLE TO DM 1 PER DISPENSER 3 1 1 1 2 1 1 1 1 1. ALL WIRING MUST CONFORM TO NEC AND LOCAL ELECTRIC CODES. 2. ALL CONDUIT AND ELECTRICAL FITTINGS MUST BE RATED FOR GROUND USE. 3. POWER CONDITIONER SHALL BE INSTALLED ACCORDING TO MANUFACTURER INSTRUCTIONS. 4. 10 GROUND BUSS SHALL BE INSULATED FROM THE PANEL VIA A NON- CONDUCTIVE MOUNTING: SQUARE D PKGTAR OR EQUIVALENT. 5. THE POWER CONDITIONER OUTPUT AND ALL ISOLATE, CONDITIONED CIRCUITS ARE TO BE RUN IN SEPARATE CONDUITS FROM ALL NON- CONDITIONED CIRCUITS. MULTIPLE CONDITIONED CIRCUITS MAY SHARE THE SAME CONDUIT. 6. ALL GROUND CONDUCTORS IN SUB PANELS MUST TERMINATE TO PROPER GROUNDING CONNECTIONS. DO NOT TERMINATE CROUNDING CONDUCTORS TO THE NEUTRAL BUSS IN A SUB - PANEL. NOTES! 1, FC NEEDS FIXED IP ADDRESS 192.168.10.10 2, DSU LOCATION? THIS ASSUMES IT IS UNDER THE FRONT COUNTER AS TODAY 3, FC ASSIGNS DM IP ADDRESSES WIRE LEGEND! CAT5 UTP CAT5 UTP PATCH CORD LEGACY SERIAL CONNECTIONS PEW BACK OFFICE PC CAR WASH CONTROLLER CASHER COUNTER PP I EPS ■ ■ PIN PAD ELECTRONIC PAYMENT SYSTEM 2 CAT 5 1 CAT 5 BP- S00 -SHF16 SCALE: NONE BP-S00-SHF1 6 0 0 O 1 1 1 1 1 2 1 1 I I 1 I_ I .I I_ :1 n= n 0 00 1 1 3 1 3 2 3 SALES COUNTER ELEVATION ISOLATED GROUND FOR SAFE (E) MAIN SWITCHBOARD U.G. PULL (E) METER /MAIN 1(E) DISTRIBUTION SECTION SECTION SECTION (E) 1 600 AMP, 120/240 VOLT, 1 PHASE, 3 WIRE BUS. VERIFY AIC ) 600/2 SCALE: NONE SI LE LINE DIAGRAM POS "B" CONVENJ RECEPTACLE 0 NEUT CONVEN, RECEPTACLE (E) PANEL 'A' I 0 - ISOLATED GROUN (1) DATA JACK (2) SIMPLEX OUTLETS (E) , (E) 0) 200/2 )400/2 0 3 1 "MSB" (E) PANEL POS "A" PANEL NOTES: 1. EXISTING BREAKER AND LOAD. 2. EXISTING BREAKER. CONNECT NEUJ LOAD. 3: INSTALL NEW BREAKER WITH ALL NECESSARY MOUNTING HARDWARE AND CONNECT NEW LOAD. LOTTERY MACHINE - ) DATA JACK FOR LOTTERY MACHINE (E) PANEL ID I KEYED NOTES: 0 0 7 - NEW 0 )100/2 NEW PANEL IC' 1- 1 /4"C. 3#3 CU. I EXPIRES 10 -24 -2010 Date Signed: Jun 30, 2009 OPEN SAFE �--CONVEN, RECEPTACLEISOLATED GROUND FOR SAFE TELEPHONE AND FAX MAXHINE 1 -1/4' CONDUIT FROM MANAGERS CPU FOR DATA CABLE 1 -1/4' CONDUIT FROM DISPENSER INTERFACE. 1-1/4' CONDUIT FROM ELECTRIC PANELS, (CLEAN POWER) 3/4' CONDUIT UNDER SLAB TO MANAGERS OFFICE FORSECURITY 1 -1/4' CONDUIT UNDER SLAB FOR GENERAL POWER, � 1 -1/4' CONDUIT UNDER SLAB TO INTERCOM TROUGH, REC CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER SACRAMENTO ENGINEERING = CONSULTANTS 10555 Old Plac D GATE N Sacramento, CA 1 1 Phone: (916) . y IT A Fax: (916)36 ft www,sacen APPRO ' +/AL Job No. 09217 REQUIRED din bp ; ,, {r 41.. ARCO BP WEST COAST PRODUCTS, LLC R. V' C1 � �'r T p� � 4'° � Z e, r 4 2. (T /NG E N G ` N��, 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION /1\ A 'T \ A A A A 1, 12 SEAL: CONFIDENTIALITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL AWANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE, ACCORDINGLY, THE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE NE MATERIALS ONLY FOR THE UNITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN AU. MATERIALS TO GLOBAL AWANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE, WHICHEVER COMES FIRST, DEVELOPMENT INFORMA11ON: 2009 RETROFIT BACKCOURT RANCH STYLE SITE 5800 ADDRESS: SOUTHCENTER BLVD. @1-5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CG AWANCE Z &DM: CHECKED BY: RH BP REPM: DRAWN BY: AWANCE PM: VERSION: _ PROJECT NO: 1975.75 DRAWING TITLE: ELECTRICAL SCHEDULES & DIAGRAMS SHEET NO: 1 ■ .4 Site PC Veritene V900 (EPS) Retalix BOS Allied box APG Cash Drawer SureP0S 500 APG Cash Drawe Epson Printer Distributed display Effective DMZ SATELLITE DISH ON ROOF POS DIAGRAM SCALE! N,T,S, PIC unit Alternate Telecom s Solution Network switch (FS116). Forecourt devices ® -000 000 o OLIO ATM ATM AREA SurePOS 500 Verrone OMNt7O0 pinpad Distributed display POS 2 PIC UNIT TLS GENERAL NOTES PIC UNIT ALLIED BOX TANK LEVEL SENSOR CAT 5 LAN CABLE TO DM 1 PER DISPENSER 3 1 1 1 2 1 1 1 1 1. ALL WIRING MUST CONFORM TO NEC AND LOCAL ELECTRIC CODES. 2. ALL CONDUIT AND ELECTRICAL FITTINGS MUST BE RATED FOR GROUND USE. 3. POWER CONDITIONER SHALL BE INSTALLED ACCORDING TO MANUFACTURER INSTRUCTIONS. 4. 10 GROUND BUSS SHALL BE INSULATED FROM THE PANEL VIA A NON- CONDUCTIVE MOUNTING: SQUARE D PKGTAR OR EQUIVALENT. 5. THE POWER CONDITIONER OUTPUT AND ALL ISOLATE, CONDITIONED CIRCUITS ARE TO BE RUN IN SEPARATE CONDUITS FROM ALL NON- CONDITIONED CIRCUITS. MULTIPLE CONDITIONED CIRCUITS MAY SHARE THE SAME CONDUIT. 6. ALL GROUND CONDUCTORS IN SUB PANELS MUST TERMINATE TO PROPER GROUNDING CONNECTIONS. DO NOT TERMINATE CROUNDING CONDUCTORS TO THE NEUTRAL BUSS IN A SUB - PANEL. NOTES! 1, FC NEEDS FIXED IP ADDRESS 192.168.10.10 2, DSU LOCATION? THIS ASSUMES IT IS UNDER THE FRONT COUNTER AS TODAY 3, FC ASSIGNS DM IP ADDRESSES WIRE LEGEND! CAT5 UTP CAT5 UTP PATCH CORD LEGACY SERIAL CONNECTIONS PEW BACK OFFICE PC CAR WASH CONTROLLER CASHER COUNTER PP I EPS ■ ■ PIN PAD ELECTRONIC PAYMENT SYSTEM 2 CAT 5 1 CAT 5 BP- S00 -SHF16 SCALE: NONE BP-S00-SHF1 6 0 0 O 1 1 1 1 1 2 1 1 I I 1 I_ I .I I_ :1 n= n 0 00 1 1 3 1 3 2 3 SALES COUNTER ELEVATION ISOLATED GROUND FOR SAFE (E) MAIN SWITCHBOARD U.G. PULL (E) METER /MAIN 1(E) DISTRIBUTION SECTION SECTION SECTION (E) 1 600 AMP, 120/240 VOLT, 1 PHASE, 3 WIRE BUS. VERIFY AIC ) 600/2 SCALE: NONE SI LE LINE DIAGRAM POS "B" CONVENJ RECEPTACLE 0 NEUT CONVEN, RECEPTACLE (E) PANEL 'A' I 0 - ISOLATED GROUN (1) DATA JACK (2) SIMPLEX OUTLETS (E) , (E) 0) 200/2 )400/2 0 3 1 "MSB" (E) PANEL POS "A" PANEL NOTES: 1. EXISTING BREAKER AND LOAD. 2. EXISTING BREAKER. CONNECT NEUJ LOAD. 3: INSTALL NEW BREAKER WITH ALL NECESSARY MOUNTING HARDWARE AND CONNECT NEW LOAD. LOTTERY MACHINE - ) DATA JACK FOR LOTTERY MACHINE (E) PANEL ID I KEYED NOTES: 0 0 7 - NEW 0 )100/2 NEW PANEL IC' 1- 1 /4"C. 3#3 CU. I EXPIRES 10 -24 -2010 Date Signed: Jun 30, 2009 OPEN SAFE �--CONVEN, RECEPTACLEISOLATED GROUND FOR SAFE TELEPHONE AND FAX MAXHINE 1 -1/4' CONDUIT FROM MANAGERS CPU FOR DATA CABLE 1 -1/4' CONDUIT FROM DISPENSER INTERFACE. 1-1/4' CONDUIT FROM ELECTRIC PANELS, (CLEAN POWER) 3/4' CONDUIT UNDER SLAB TO MANAGERS OFFICE FORSECURITY 1 -1/4' CONDUIT UNDER SLAB FOR GENERAL POWER, � 1 -1/4' CONDUIT UNDER SLAB TO INTERCOM TROUGH, REC CITY OF TUKWILA JUL 0 8 2009 PERMIT CENTER SACRAMENTO ENGINEERING = CONSULTANTS 10555 Old Plac D GATE N Sacramento, CA 1 1 Phone: (916) . y IT A Fax: (916)36 ft www,sacen APPRO ' +/AL Job No. 09217 REQUIRED d.ENi! bp 416„... IF ARCO BP WEST COAST PRODUCTS, LLC OP & 4 L' .0. C 40 � 111111P- ',. iii e"; 4 '4, • t 5' HQ ENG' 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251-6222 (425)251 -8782 FAX CML ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION li\ 6/22/09 CRY PLANCHECK A 1600 400 A - 400 A 2000 1600 400 400 - A EF -1 - A - - A \ -650 CEF -1 A - - A 65 -65 AX - - A - 65 SEAL: CONRDENTIAUTY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL AWANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL ALLIANCE. ACCORDINGLY, NE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE UNITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES ID RETURN ALL MATERIALS TO GLOBAL AWANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON THE REQUEST OF GLOBAL AWANCE, XNICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @1-5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: EH ALLIANCE Z &DM: CHECKED BY RH BP REPM: DRAWN BY: CBC ALLIANCE PM: VERSION: - _ PROJECT N0: 1975.75 DRAWING TITLE: MECHANICAL PLAN, SCHEDULES, NOTES, & DETAILS SHEET NO: et, { r., r AIR BALANCE SCHEDULE UNIT TAG SUPPLY AIR RETURN AIR OUTSIDE AIR MAKE -UP AIR EXHAUST AIR BLDG. PRESS. FC -1 2000 1600 400 400 - 400 FC -2 2000 1600 400 400 - 400 EF -1 - - - - 650 -650 CEF -1 - - - - 65 -65 CEF -2 - - - - 65 -65 TOTALS 4000 3200 S00 SO0 - ISO 20 NO FAN ITEM W SIZE B 1 # 1 Curb 19.500 "W x 19.500 "L x 22.000 "H Vented FAN MODEL HT Fan W Mfg. B C RPM F Phase R RO WEIGHT LB DU33HFA 24 3/4 25 1/2 1 1/2 21 18 1/2 12 1/8 17 1/2 - Hood Tag Fan Model Mfg. CFM S.P. RPM H.P. Phase Volts 1 EF - EXHAUST DU33HFA CAS 650 0.50" 1258 0.33 1 115 HOOD NO. MODEL , LENGTH COOKING P AIR REQUIREMENTS HOOD CONST. EXHAUST RISER QTY. SIZE CFM/ RISER SP TOTAL EXH. CFM W L 1 VH1 5424 3'0" -- DE . 1 8 8 650 0.25" 650 100% TYPE 430 S/s DIA THE TRANSITION BETWEEN 21" SQ. — THE DUCTWORK AND FAN DUCTWORK BETWEEN EXHAUST RISER BASE SHOULD BE EQUAL ON HOOD AND FAN (BY OTHERS) TO OR GREATER THAN R UPBLAST EXHAUST FAN (DIA) DIMENSION MODEL #DU33HFA (95 LBS EACH) EXHAUST FAN DETAIL NTS r . : rl ,� i . _ I I I I! I I EXISTING COVERED TRASH ENCLOSURE BACKROOM ampm COFFEE EXISTING STORAGE NEW UNISEX REST ROOM EXISTING STORAGE CONTAINER UNDERCUT DOOR EXISTING SALES AREA CASHIER 1) MECHANICAL PLAN SCALE: 1/4"= ' -0" CURB ASSEMBLIES -�- 25 1 /2" DIA J 1 1/2" 20" VENTED CURB ETL LISTED PER UL 705 20 GAUGE ALUMINIZED STEEL CONSTRUCTION 3" CONTINUOUS FLASHING ROOF OPENING DIMENSIONS 18" X 18" 18" 18" FEATURES: — ROOF MOUNTED FANS - RESTAURANT MODEL — UL762 — VARIABLE SPEED CONTROL — INTERNAL WIRING — - THERMAL WEATHERPROOF OVERLOAD PROTECTION SINGLE PHASE) - HIGH HEAT OPERATION 300'F (149'C) OPTIONS: HINGED FAN PITCHED CURB INSULATED CURB DUL /HFA DIRECT DRIVE CENTRIFUGAL UP —BLAST EXHAUST FANS DIMENSIONAL DATA x :1 EXHAUST FAN • 0 4 " eL 6" MINIMUM ALL SIDES EQUIPMENT BY OTHERS 54" SEE FAN DRAWING FOR DETAILS OFFSET AS REQUIRED EXHAUST RISER FULL LENGTH ANGLE (TYPICAL) i 24" COOKING SURFACE V SECTION VIEW — MODEL 5424 —VH1 SECTION THRU HOOD NTS 0 0 0 0 0 0 0 0 U- 0 0 0 LL CEILING MOUNT 6' -9" ABOVE FLOOR FAN INFORMATION SCHEDULE HOOD INFORMATON TABLE HOOD & FAN INFORMATION NTS GENERAL NOTE: 1 CONTRACTOR TO INSPECT EXISTING MECHANICAL UNITS. REPAIR, REPLACE DEFECTIVE PARTS, LEAVE IN LIKE NEW CONDITION. CHECK REFRIGERATION LEVELS AFTER PRESSURE CHECK, RECHARGE IF REQUIRED, CHEMICALLY CLEAN EVAPORATOR AND CONDENSER COILS. INSTALL NEW CONDENSATE DRAIN IF REQUIRED. REBALANCE AIR QUANTITIES TO PROVIDE ADEQUATE OUTSIDE AIR REQUIRED BY CODE AND TO BALANCE THE SPACE TO A MINIMUM OF +200 CFM. 2. INTERLOCK FAN OPERATION OF "TYPE II EXHAUST HOOD" WITH FC -1 AND FC -2 FAN OPERATION. THE OUTSIDE AIR FROM THE EXISTING HVAC UNITS SHALL BE USED AS MAKE -UP AIR FOR THE EXHAUST FANS. KEYED NOTES: O NOT USED O CONTRACTOR TO INSTALL CAPTIVAIRE VH1 54 "X 36" EXHAUST HOOD ABOVE CONVECTION OVEN (TG7). HOOD TO BE PROVIDED BY GC. INSTALLED BY CONTRACTOR. PROVIDE ALL 3/8 ALL THREARD ROD AND HANG ACROSS THREE EXISTING JOISTS WITH UNISTRUT. O 10" SQUARE DUCT FROM TYPE II HOOD TO EXHAUST FAN SHALL BE SEALED LIQIUD TIGHT. O INSTALL NEW CAPTIVAIRE DU33HFA EXHAUST FAN MOUNTED ON ROOF. FAN TO BE PROVIDED BY GC. INSTALLED BY CONTRACTOR. FAN IS TO BE A MINIMUM OF 10 FEET FROM ANY OUTSIDE AIR INTAKES, AND A MINIMUM OF 40" FROM PARAPET WALLS. O EXISTING DIFFUSER /GRILLES TO REMAIN. ADJUST DIFFUSERS AS REQUIRED TO FIT WITHIN CEILING GRID. ALL DIFFUSERS AND GRILLES SHALL BE CLEANED AND REPAINTED. O CONTRACTOR SHALL RELOCATE 12 "x12" RETURN GRILLE ABOVE THE FROZEN BEVERAGE DISPENSER. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT DUCTWORK AS REQUIRED. O CONTRACTOR SHALL RELOCATE 12 "x12" BATHROOM EXHAUST FAN TO NEW RESTROOM LOCATION. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT DUCTWORK AS REQUIRED. PLAN VIEW — 3' 0.00" LONG 5424VH1 HOOD PLAN VIEW NTS I EXPIRES 10 -24 -201 Date Signed: Jun 30, 2009 FACTORY LOCATED & INSTALLED HANGER ANGLES (TYPICAL) .00 "Nom. /3' 0.50 "OD M.ry RECEIVED CITY OF TUKWILA JUL U 8 1009 PERMIT CENTER SACRAMENTO ENO /NEER /NO = CO TE 10555 Old Pl.t • 1- „� " Sacramento, C "'":41" , JJ n ND Phone: (916 �1(��� /`Y Fox: (916 V L www.sa e V/'� .r ;' L 'N) ) •,. Job No. 0921/ QUIRE 0 O 27" L i 4 " % __.] " [.__ 0 0 Hood #1 - � --■-- 18" 18" 3 C DIA THE TRANSITION BETWEEN 21" SQ. — THE DUCTWORK AND FAN DUCTWORK BETWEEN EXHAUST RISER BASE SHOULD BE EQUAL ON HOOD AND FAN (BY OTHERS) TO OR GREATER THAN R UPBLAST EXHAUST FAN (DIA) DIMENSION MODEL #DU33HFA (95 LBS EACH) EXHAUST FAN DETAIL NTS r . : rl ,� i . _ I I I I! I I EXISTING COVERED TRASH ENCLOSURE BACKROOM ampm COFFEE EXISTING STORAGE NEW UNISEX REST ROOM EXISTING STORAGE CONTAINER UNDERCUT DOOR EXISTING SALES AREA CASHIER 1) MECHANICAL PLAN SCALE: 1/4"= ' -0" CURB ASSEMBLIES -�- 25 1 /2" DIA J 1 1/2" 20" VENTED CURB ETL LISTED PER UL 705 20 GAUGE ALUMINIZED STEEL CONSTRUCTION 3" CONTINUOUS FLASHING ROOF OPENING DIMENSIONS 18" X 18" 18" 18" FEATURES: — ROOF MOUNTED FANS - RESTAURANT MODEL — UL762 — VARIABLE SPEED CONTROL — INTERNAL WIRING — - THERMAL WEATHERPROOF OVERLOAD PROTECTION SINGLE PHASE) - HIGH HEAT OPERATION 300'F (149'C) OPTIONS: HINGED FAN PITCHED CURB INSULATED CURB DUL /HFA DIRECT DRIVE CENTRIFUGAL UP —BLAST EXHAUST FANS DIMENSIONAL DATA x :1 EXHAUST FAN • 0 4 " eL 6" MINIMUM ALL SIDES EQUIPMENT BY OTHERS 54" SEE FAN DRAWING FOR DETAILS OFFSET AS REQUIRED EXHAUST RISER FULL LENGTH ANGLE (TYPICAL) i 24" COOKING SURFACE V SECTION VIEW — MODEL 5424 —VH1 SECTION THRU HOOD NTS 0 0 0 0 0 0 0 0 U- 0 0 0 LL CEILING MOUNT 6' -9" ABOVE FLOOR FAN INFORMATION SCHEDULE HOOD INFORMATON TABLE HOOD & FAN INFORMATION NTS GENERAL NOTE: 1 CONTRACTOR TO INSPECT EXISTING MECHANICAL UNITS. REPAIR, REPLACE DEFECTIVE PARTS, LEAVE IN LIKE NEW CONDITION. CHECK REFRIGERATION LEVELS AFTER PRESSURE CHECK, RECHARGE IF REQUIRED, CHEMICALLY CLEAN EVAPORATOR AND CONDENSER COILS. INSTALL NEW CONDENSATE DRAIN IF REQUIRED. REBALANCE AIR QUANTITIES TO PROVIDE ADEQUATE OUTSIDE AIR REQUIRED BY CODE AND TO BALANCE THE SPACE TO A MINIMUM OF +200 CFM. 2. INTERLOCK FAN OPERATION OF "TYPE II EXHAUST HOOD" WITH FC -1 AND FC -2 FAN OPERATION. THE OUTSIDE AIR FROM THE EXISTING HVAC UNITS SHALL BE USED AS MAKE -UP AIR FOR THE EXHAUST FANS. KEYED NOTES: O NOT USED O CONTRACTOR TO INSTALL CAPTIVAIRE VH1 54 "X 36" EXHAUST HOOD ABOVE CONVECTION OVEN (TG7). HOOD TO BE PROVIDED BY GC. INSTALLED BY CONTRACTOR. PROVIDE ALL 3/8 ALL THREARD ROD AND HANG ACROSS THREE EXISTING JOISTS WITH UNISTRUT. O 10" SQUARE DUCT FROM TYPE II HOOD TO EXHAUST FAN SHALL BE SEALED LIQIUD TIGHT. O INSTALL NEW CAPTIVAIRE DU33HFA EXHAUST FAN MOUNTED ON ROOF. FAN TO BE PROVIDED BY GC. INSTALLED BY CONTRACTOR. FAN IS TO BE A MINIMUM OF 10 FEET FROM ANY OUTSIDE AIR INTAKES, AND A MINIMUM OF 40" FROM PARAPET WALLS. O EXISTING DIFFUSER /GRILLES TO REMAIN. ADJUST DIFFUSERS AS REQUIRED TO FIT WITHIN CEILING GRID. ALL DIFFUSERS AND GRILLES SHALL BE CLEANED AND REPAINTED. O CONTRACTOR SHALL RELOCATE 12 "x12" RETURN GRILLE ABOVE THE FROZEN BEVERAGE DISPENSER. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT DUCTWORK AS REQUIRED. O CONTRACTOR SHALL RELOCATE 12 "x12" BATHROOM EXHAUST FAN TO NEW RESTROOM LOCATION. REFER TO ARCHITECTURAL DEMOLITION PLAN FOR FURTHER INFORMATION. EXTEND AND RECONNECT DUCTWORK AS REQUIRED. PLAN VIEW — 3' 0.00" LONG 5424VH1 HOOD PLAN VIEW NTS I EXPIRES 10 -24 -201 Date Signed: Jun 30, 2009 FACTORY LOCATED & INSTALLED HANGER ANGLES (TYPICAL) .00 "Nom. /3' 0.50 "OD M.ry RECEIVED CITY OF TUKWILA JUL U 8 1009 PERMIT CENTER SACRAMENTO ENO /NEER /NO = CO TE 10555 Old Pl.t • 1- „� " Sacramento, C "'":41" , JJ n ND Phone: (916 �1(��� /`Y Fox: (916 V L www.sa e V/'� .r ;' L 'N) ) •,. Job No. 0921/ QUIRE CLEt!'It b 401. 1r ARCO BP WEST COAST PRODUCTS, LLC V' 2 �� / X 44, et f of Q` <T / H G EN G`N� 18215 72ND AVENUE SOUTH KENT, WA 98032 (425)251 -6222 (425)251 -8782 FAX CML ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES NO. DATE REVISION DESCRIPTION /1\ 6/22/09 CITY PLANCHECK WATER CLOSET "CADET 3" ELONGATED,WHITE CHINA, FLOOR MOUNTED WITH VANDAL PROOF LID, AND OLSONITE #95 OPEN FRONT SEAT. BOWL MODEL 3016.016, TANK 4021.900 WITH LEFT HAND TRIP LEVER 1/2" CW 4" A FW LAV1 A 18 1/2 "x17" "DECLYN "WALL HUNG, WHITE CHINA, SLOAN BATTERY OPERATED SENSOR FAUCET MODEL # EBF -650 1 /2 "HW & CW 1 1/4" AMERICAN STANDARD 0321.026 Q© NOTES. 0 INSULATE WATER SUPPLY AND WASTE PIPING UNDER HANDICAPPED LAVATORIES WITH "HANDI LAV" GUARD JACKET BY TRUEBRO. 45 HOLE DRILLING, GRID STRAINER AND STOPS. © WATER CLOSETS TO HAVE LEFT TRIP LEVER. EXISTING SANITARY A EXISTING VENT (E)CW A \ A (E)FW (E)HW - - -- A ---- R - - --1- RELOCATED FIXTURE 11 SEAL: CONFIDENTIAL ITY STATEMENT: THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT COPYRIGHT IN THE MATERIALS IS OWNED BY GLOBAL AWANCE, AND ALSO, THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL BUSINESS INFORMATION OF GLOBAL AWANCE. ACCORDINGLY, NE RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT CONFIDENCE AND AGREES NOT TO DISCLOSE THESE MATERIALS TO ANY OTHER PARTY AND FURTHER AGREES NOT TO MAKE COPIES OF THE MATERIALS. THE RECIPIENT AGREES TO USE THE MATERIALS ONLY FOR THE LIMITED PURPOSE FOR WHICH GLOBAL AWANCE HAS MADE THE MATERIALS AVAILABLE, AND RECIPIENT AGREES TO RETURN ALL MATERIALS TO GLOBAL ALLIANCE EITHER UPON COMPLETION OF THE INTENDED PURPOSE OR UPON NE REQUEST OF GLOBAL AWANCE, WHICHEVER COMES FIRST. DEVELOPMENT INFORMATION: 2009 RETROFIT BACKCOURT RANCH STYLE SITE ADDRESS: 5800 SOUTHCENTER BLVD. @1.5 TUKWILA, WASHINGTON FAC 83098 DESIGNED BY: CBC AWANCE Z &DM: CHECKED BY: EH BP REPM: DRAWN BY: CBC ALLIANCE PM: VERSION: .. - . PROJECT NO: 1975.75 DRAWING TITLE: PLUMBING DEMOLITION / ROUGH -IN PLANS, NOTES, LEGENDS, AND DETAILS SHEET NO: P.1.1 4.44 14 SCALE: 3/16 ":1' -0" Ca CCII 1 2 FILTERED CW FROM RELOCATED OVERHEAD CARBONATORS 3 4" FILTERED CW +24" TEE -OFF 1/4" EACH FOR RELOCATED CAPPUCCINO MAKER AND DUAL SOFT HEAT BREWER. TEE -OFF 3/8" EACH FOR ICED LATTE AND LATTE STEAMER. 3 4" FILTERED CW +36" EXTEND 1/2" EACH FOR RELOCATED FOUNTAIN ICE MAKERS AND RELOCATED B12 20 -VALVE ICE /BEVERAGE DISPENSER C B1B )3/8" FILTERED CW +30" RELOCATED FROZEN BEVERAGE DISPENSER SCALE: 3/16' =1' -0" EXISTING OFFICE EXISTING OFFICE 11 I I' 1 II.1 I I . I I 1 11 Z 1- z 0 m U EXISTING COVERED TRASH ENCLOSURE 0 11 11 I I I I 11 PLUMBING DEMOLITION PLAN PLUMBING ROUGH -IN PLAN x r EXISTING REST ROCS te a, I I I II > O EXISTING COVERED TRASH ENCLOSURE (G8 `3—R" r RELO w 0 (E)4= BACKROOM I am pm COFFEE 1 IN - x EXISTING STORAGE 0 1 � BACKROOM TANK PAta "A" 1# NITOR 11 07 G7 It / \ 1 3 "GW w 3 "FCO 0 . t I / / / / / 1/2" HW & CW +36" MOP SINK " DIRECT CONNECTION OP SINK EXISTING STORAGE FROM_ WATER SER_ CE I: TED WATER HEATS' / / / / / / ICI II I.ri 1 • S L 12 "HW &CW +8" 3— COMPARTMENT SINK, PRERINSE SPRAY/FAUCET _31 HAND SINK, G9E EXISTING STORAGE CONTAINER rrrnnmrTl A' (111111111111 1 2" CW +10" 3" DRAIN THRU FLOOR SLAB WATER CLOSET 2" WASTE 11-IRU FLOOR 16A HAND SINK' 1/2" HW & C\ '' +12" NEW UNISEX REST ROOM I I I I 11 II EXISTING STORAGE CONTAINER CD G16 1 2" & CW +23" 18.1./_2" LAVORA_T.ORY_. - EXISTING SALES r- AREA CASHIER 1 CASHIER rrrrrnhlr1T1'ITTir 1111111111111111111 . LLIJSIlLIULLUU� EXISTING SALES AREA L I XISTING REFAB OOLER 4 1 41 XISTING REFAB OOLER 2 NEW 1/2" CW NEW 1 -1/2" VENT SCALE: NO SCALE SCALE: NO SCALE PRE - FILTER SCALE: NO SCALE 1/2" CW 1 -1/2" VENT 2" WASTE FILTERED WATER TO ABOVE CEILING FOR CARBONATOR 1/2" DRAIN TO FLOOR SINK. NEW 1/2" HW L Y ' NEW 2" WASTE MOUNT FLUSH WITH FLOOR TYPICAL SINK INSTALLATION FINISHED FLOOR 1/2" HW— l'N t• i FLOOR GRATE TO BE FASTENED DOWN WITH SCREWS - NOTES A. FLOOR DRAIN COVER FLUSH WITH TILE OR FLUSH WITH CONCRETE FLOOR IN AREA WITH NO TILE SCALE: NO SCALE EXISTING HOT AND COLD WATER PIPING ABOVE CEILING, FIELD VERIFY LOCATION AND MATERIAL EXISTING VENT PIPING ABOVE CEILING, FIELD VERIFY LOCATION AND MATERIAL � � NEW TEE 400■ NEW SINK 4400 II/ N./ '�' EXISTING HOT AND COLD WATER PIPING ,,�� ABOVE CEILING, FIELD VERIFY LOCATION AND MATERIAL EXISTING VENT PIPING ABOVE CEILING, FIELD VERIFY LOCATION AND MATERIAL - TEE SAW CUT AND REMOVE FLOOR SLAB FOR PIPING INSTALLATION AS REQUIRED EXISTING WASTE PIPING, FIELD VERIFY LOCATION AND MATERIAL INSTALL REPAIR COUPLING (rw 2 ) INSTALL NEW TEE EXISTING WASTE PIPING, FIELD VERIFY LOCATION AND MATERIAL INSTALL REPAIR COUPUNG (rn' 2 ) INSTALL NEW TEE TYPICAL MOP SINK INSTALLATION FILTERED WATER TO ABOVE CEIUNG FOR ICE MAKERS, COFFEE BREWER, STEAMER MACHINE, CAPPUCCINO MAKER, AND AIR POT BREWER. EVERPURE WATER FILTER REFER TO SHEET Q6.1 FOR MORE INFORMATION WATER FILTER DETAIL (EXISTING). 1 .1.1 / i FLOOR SINK "FS -1" DETAIL 1" MINIMUM _^-HUB OUTLET CEILING DISCHARGE PIPE 3 P.1.1 6 P.1.1 GENERAL NOTES: 1. INDIRECT WASTE DRAIN LINES TO TO DISCHARGE ABOVE FLOOR SINK WITH AN AIR GAP OF AT LEAST MINIMUM OF TWICE PIPING I.D. AND NOT LESS THAN 1 INCH AIR GAP BETWEEN INDIRECT WASTE PIPING OUTLET AND FLOOD RIM OF FLOOR SINK, PER WPC 603.3.5, 608.5, 801.1. 2. HORIZONTAL DRAINAGE PIPING GRADE SHALL BE NOT LESS THAN 1/4 ":12 SLOPE, PER WPC 708.0. INDIRECT DRAIN UNE GRADE TO BE NOT LESS THAN 1/4 ":12 SLOPE, PER WPC 814.0. 4. FIELD VERIFY EXISTING REDUCED PRESSURE PRINCIPLE ASSEMBLY, A STAINLESS STEEL REDUCED PRESSURE BACKFLOW PREVENTER SHALL BE USED IN THE POTABLE WATER SUPPLY TO CARBONATORS. INSTALL OR REPLACE (IF NOT STAINLESS STEEL) WITH WATTS 009QT -Y2. ALL BACKFLOW PREVENTION DEVICES SHALL BE TESTED AND LABELED APPROVED BY A CERTIFIED BACKFLOW ASSEMBLY TESTING AGENCY AFTER INSTALLATION AND PRIOR TO FINAL PLUMBING INSPECTION, PER UPC /CPC 603.2.2 INDIRECT WASTE DRAIN LINE FROM CARBONATOR SPILLAGE -TYPE BACKFLOW PREVENTER SHALL DISCHARGE WITH AIR GAP TO FLOOR SINK, PER DETAIL 6/P.1.1 THIS SHEET. 6. THE DRAIN LINE OUTLET FROM THE CARBONATOR (G54) BACKFLOW PREVENTER SHALL BE TERMINATED TO FLOOR SINK, PER DETAIL 6/P.1.1 THIS SHEET. 7 THE DRAIN LINE OUTLET FROM THE 20 -VALVE ICE/BEVERAGE DISPENSER (B12) SHALL TERMINATED TO FLOOR SINK, PER DETAIL 6/P1.1 THIS SHEET. 1/2" 1 / 2 ✓ �/I� \�AMTROL ST -12 s K A10 • ~ WATER RISER SCALE: NO SCALE RPBP, WATTS 009QT -Y2. '\ '\ NUMBERED KEY NOTES: O EXISTING LAVATORY TO BE REMOVED. CONTRACTOR SHALL CAP EXISTING PLUMBING LINES AND PATCH SLAB FLUSH WITH EXISTING CONCRETE SLAB AS REQUIRED. O EXISTING WATER CLOSET TO BE REMOVED. CONTRACTOR SHALL CAP EXISTING PLUMBING LINES AND PATCH SLAB FLUSH WITH EXISTING CONCRETE SLAB AS REQUIRED. NG 600LB ICE MAKER (G6A) TO REMAIN. ® EXISTING UTILITY SINK TO BE REMOVED. CONTRACTOR SHALL CAP EXISTING PLUMBING LINES AND PATCH SLAB FLUSH WITH EXISTING CONCRETE SLAB AS REQUIRED. EXI i PLUMBING CONTRACTOR SHALL ROUTE THE 3" GREASY WASTE UNE TO EXISTING GREASE INTERCEPTOR. A10 Ic)c, - A15 EXISTING WATER HEATER (G8) TO BE RELOCATED WITH HI /LOW STRAPS, UPPER AND LOWER 1/3 OF UNIT. REFER TO ARCHITECTURAL DWGS FOR FURTHER INFORMATION. EXTEND AND RECONNECT EXISTING PLUMBING SERVICES TO NEW LOCATION. EXISTING WATER PURIFICATION SYSTEM (G11) TO REMAIN. EXISTING CARBONATORS (G54) AND ASSOCIATED PLUMBING TO BE RELOCATED. REFER TO ARCHITECTURAL DWGS FOR FURTHER INFORMATION. EXTEND AND RECONNECT EXISTING PLUMBING SERVICES TO NEW LOCATION EXISTING FOUNTAIN, FCB AND COFFEE STATIONS TO BE RELOCATED. REFER TO ARCHITECTURAL DWGS FOR FURTHER INFORMATION. EXTEND AND RECONNECT ASSOCIATED PLUMBING SERVICES TO NEW LOCATION. NEW FLOOR SINK (FS -1) TO BE INSTALLED, PER DETAIL 6/P1.1 THIS SHEET. 2" VENT RISER, CONNECT TO EXISTING HORIZONTAL 2" VENT ABOVE CEIUNG, FIELD VERIFY. EXISTING FLOOR SINK TO REMAIN. EXISTING SINK TO BE REMOVED. CONTRACTOR SHALL CAP EXISTING PLUMBING LINES AND PATCH SLAB FLUSH WITH EXISTING CONCRETE SLAB AS REQUIRED. WATER FILTRATION B2A B12 3/4" B1A B1A \• ,� A6 ,/ /' G9B G6C (G16A) , (REFERENCE ONLY) EXPIRES 10 -24 -2010 I Date . Signed: Jun 30, 2009 RECEIVED CITY OF TUKWILA JUL 048 2009 PERMIT CENTER SA Job No. 09217 7 P.1.1 10555 Old Sacramen ) dn D r d3l/► Phone (9 to �/A Fax .c rw �'' www saceng.c• G 1 /2" PLUMBING FIXTURE SCHEDULE MARK EOUQ'MBVT DESCRIPTION/ ACCESSORIES SUPPLY PIPING WASTE PIPING MANUFACTURER/ MODEL NOTES WC —1 WATER CLOSET "CADET 3" ELONGATED,WHITE CHINA, FLOOR MOUNTED WITH VANDAL PROOF LID, AND OLSONITE #95 OPEN FRONT SEAT. BOWL MODEL 3016.016, TANK 4021.900 WITH LEFT HAND TRIP LEVER 1/2" CW 4" AMERICAN STANDARD 2386.012 FW LAV1 HANDICAP LAVATORY 18 1/2 "x17" "DECLYN "WALL HUNG, WHITE CHINA, SLOAN BATTERY OPERATED SENSOR FAUCET MODEL # EBF -650 1 /2 "HW & CW 1 1/4" AMERICAN STANDARD 0321.026 Q© NOTES. 0 INSULATE WATER SUPPLY AND WASTE PIPING UNDER HANDICAPPED LAVATORIES WITH "HANDI LAV" GUARD JACKET BY TRUEBRO. 45 HOLE DRILLING, GRID STRAINER AND STOPS. © WATER CLOSETS TO HAVE LEFT TRIP LEVER. SCALE: 3/16 ":1' -0" Ca CCII 1 2 FILTERED CW FROM RELOCATED OVERHEAD CARBONATORS 3 4" FILTERED CW +24" TEE -OFF 1/4" EACH FOR RELOCATED CAPPUCCINO MAKER AND DUAL SOFT HEAT BREWER. TEE -OFF 3/8" EACH FOR ICED LATTE AND LATTE STEAMER. 3 4" FILTERED CW +36" EXTEND 1/2" EACH FOR RELOCATED FOUNTAIN ICE MAKERS AND RELOCATED B12 20 -VALVE ICE /BEVERAGE DISPENSER C B1B )3/8" FILTERED CW +30" RELOCATED FROZEN BEVERAGE DISPENSER SCALE: 3/16' =1' -0" EXISTING OFFICE EXISTING OFFICE 11 I I' 1 II.1 I I . I I 1 11 Z 1- z 0 m U EXISTING COVERED TRASH ENCLOSURE 0 11 11 I I I I 11 PLUMBING DEMOLITION PLAN PLUMBING ROUGH -IN PLAN x r EXISTING REST ROCS te a, I I I II > O EXISTING COVERED TRASH ENCLOSURE (G8 `3—R" r RELO w 0 (E)4= BACKROOM I am pm COFFEE 1 IN - x EXISTING STORAGE 0 1 � BACKROOM TANK PAta "A" 1# NITOR 11 07 G7 It / \ 1 3 "GW w 3 "FCO 0 . t I / / / / / 1/2" HW & CW +36" MOP SINK " DIRECT CONNECTION OP SINK EXISTING STORAGE FROM_ WATER SER_ CE I: TED WATER HEATS' / / / / / / ICI II I.ri 1 • S L 12 "HW &CW +8" 3— COMPARTMENT SINK, PRERINSE SPRAY/FAUCET _31 HAND SINK, G9E EXISTING STORAGE CONTAINER rrrnnmrTl A' (111111111111 1 2" CW +10" 3" DRAIN THRU FLOOR SLAB WATER CLOSET 2" WASTE 11-IRU FLOOR 16A HAND SINK' 1/2" HW & C\ '' +12" NEW UNISEX REST ROOM I I I I 11 II EXISTING STORAGE CONTAINER CD G16 1 2" & CW +23" 18.1./_2" LAVORA_T.ORY_. - EXISTING SALES r- AREA CASHIER 1 CASHIER rrrrrnhlr1T1'ITTir 1111111111111111111 . LLIJSIlLIULLUU� EXISTING SALES AREA L I XISTING REFAB OOLER 4 1 41 XISTING REFAB OOLER 2 NEW 1/2" CW NEW 1 -1/2" VENT SCALE: NO SCALE SCALE: NO SCALE PRE - FILTER SCALE: NO SCALE 1/2" CW 1 -1/2" VENT 2" WASTE FILTERED WATER TO ABOVE CEILING FOR CARBONATOR 1/2" DRAIN TO FLOOR SINK. NEW 1/2" HW L Y ' NEW 2" WASTE MOUNT FLUSH WITH FLOOR TYPICAL SINK INSTALLATION FINISHED FLOOR 1/2" HW— l'N t• i FLOOR GRATE TO BE FASTENED DOWN WITH SCREWS - NOTES A. FLOOR DRAIN COVER FLUSH WITH TILE OR FLUSH WITH CONCRETE FLOOR IN AREA WITH NO TILE SCALE: NO SCALE EXISTING HOT AND COLD WATER PIPING ABOVE CEILING, FIELD VERIFY LOCATION AND MATERIAL EXISTING VENT PIPING ABOVE CEILING, FIELD VERIFY LOCATION AND MATERIAL � � NEW TEE 400■ NEW SINK 4400 II/ N./ '�' EXISTING HOT AND COLD WATER PIPING ,,�� ABOVE CEILING, FIELD VERIFY LOCATION AND MATERIAL EXISTING VENT PIPING ABOVE CEILING, FIELD VERIFY LOCATION AND MATERIAL - TEE SAW CUT AND REMOVE FLOOR SLAB FOR PIPING INSTALLATION AS REQUIRED EXISTING WASTE PIPING, FIELD VERIFY LOCATION AND MATERIAL INSTALL REPAIR COUPLING (rw 2 ) INSTALL NEW TEE EXISTING WASTE PIPING, FIELD VERIFY LOCATION AND MATERIAL INSTALL REPAIR COUPUNG (rn' 2 ) INSTALL NEW TEE TYPICAL MOP SINK INSTALLATION FILTERED WATER TO ABOVE CEIUNG FOR ICE MAKERS, COFFEE BREWER, STEAMER MACHINE, CAPPUCCINO MAKER, AND AIR POT BREWER. EVERPURE WATER FILTER REFER TO SHEET Q6.1 FOR MORE INFORMATION WATER FILTER DETAIL (EXISTING). 1 .1.1 / i FLOOR SINK "FS -1" DETAIL 1" MINIMUM _^-HUB OUTLET CEILING DISCHARGE PIPE 3 P.1.1 6 P.1.1 GENERAL NOTES: 1. INDIRECT WASTE DRAIN LINES TO TO DISCHARGE ABOVE FLOOR SINK WITH AN AIR GAP OF AT LEAST MINIMUM OF TWICE PIPING I.D. AND NOT LESS THAN 1 INCH AIR GAP BETWEEN INDIRECT WASTE PIPING OUTLET AND FLOOD RIM OF FLOOR SINK, PER WPC 603.3.5, 608.5, 801.1. 2. HORIZONTAL DRAINAGE PIPING GRADE SHALL BE NOT LESS THAN 1/4 ":12 SLOPE, PER WPC 708.0. INDIRECT DRAIN UNE GRADE TO BE NOT LESS THAN 1/4 ":12 SLOPE, PER WPC 814.0. 4. FIELD VERIFY EXISTING REDUCED PRESSURE PRINCIPLE ASSEMBLY, A STAINLESS STEEL REDUCED PRESSURE BACKFLOW PREVENTER SHALL BE USED IN THE POTABLE WATER SUPPLY TO CARBONATORS. INSTALL OR REPLACE (IF NOT STAINLESS STEEL) WITH WATTS 009QT -Y2. ALL BACKFLOW PREVENTION DEVICES SHALL BE TESTED AND LABELED APPROVED BY A CERTIFIED BACKFLOW ASSEMBLY TESTING AGENCY AFTER INSTALLATION AND PRIOR TO FINAL PLUMBING INSPECTION, PER UPC /CPC 603.2.2 INDIRECT WASTE DRAIN LINE FROM CARBONATOR SPILLAGE -TYPE BACKFLOW PREVENTER SHALL DISCHARGE WITH AIR GAP TO FLOOR SINK, PER DETAIL 6/P.1.1 THIS SHEET. 6. THE DRAIN LINE OUTLET FROM THE CARBONATOR (G54) BACKFLOW PREVENTER SHALL BE TERMINATED TO FLOOR SINK, PER DETAIL 6/P.1.1 THIS SHEET. 7 THE DRAIN LINE OUTLET FROM THE 20 -VALVE ICE/BEVERAGE DISPENSER (B12) SHALL TERMINATED TO FLOOR SINK, PER DETAIL 6/P1.1 THIS SHEET. 1/2" 1 / 2 ✓ �/I� \�AMTROL ST -12 s K A10 • ~ WATER RISER SCALE: NO SCALE RPBP, WATTS 009QT -Y2. '\ '\ NUMBERED KEY NOTES: O EXISTING LAVATORY TO BE REMOVED. CONTRACTOR SHALL CAP EXISTING PLUMBING LINES AND PATCH SLAB FLUSH WITH EXISTING CONCRETE SLAB AS REQUIRED. O EXISTING WATER CLOSET TO BE REMOVED. CONTRACTOR SHALL CAP EXISTING PLUMBING LINES AND PATCH SLAB FLUSH WITH EXISTING CONCRETE SLAB AS REQUIRED. NG 600LB ICE MAKER (G6A) TO REMAIN. ® EXISTING UTILITY SINK TO BE REMOVED. CONTRACTOR SHALL CAP EXISTING PLUMBING LINES AND PATCH SLAB FLUSH WITH EXISTING CONCRETE SLAB AS REQUIRED. EXI i PLUMBING CONTRACTOR SHALL ROUTE THE 3" GREASY WASTE UNE TO EXISTING GREASE INTERCEPTOR. A10 Ic)c, - A15 EXISTING WATER HEATER (G8) TO BE RELOCATED WITH HI /LOW STRAPS, UPPER AND LOWER 1/3 OF UNIT. REFER TO ARCHITECTURAL DWGS FOR FURTHER INFORMATION. EXTEND AND RECONNECT EXISTING PLUMBING SERVICES TO NEW LOCATION. EXISTING WATER PURIFICATION SYSTEM (G11) TO REMAIN. EXISTING CARBONATORS (G54) AND ASSOCIATED PLUMBING TO BE RELOCATED. REFER TO ARCHITECTURAL DWGS FOR FURTHER INFORMATION. EXTEND AND RECONNECT EXISTING PLUMBING SERVICES TO NEW LOCATION EXISTING FOUNTAIN, FCB AND COFFEE STATIONS TO BE RELOCATED. REFER TO ARCHITECTURAL DWGS FOR FURTHER INFORMATION. EXTEND AND RECONNECT ASSOCIATED PLUMBING SERVICES TO NEW LOCATION. NEW FLOOR SINK (FS -1) TO BE INSTALLED, PER DETAIL 6/P1.1 THIS SHEET. 2" VENT RISER, CONNECT TO EXISTING HORIZONTAL 2" VENT ABOVE CEIUNG, FIELD VERIFY. EXISTING FLOOR SINK TO REMAIN. EXISTING SINK TO BE REMOVED. CONTRACTOR SHALL CAP EXISTING PLUMBING LINES AND PATCH SLAB FLUSH WITH EXISTING CONCRETE SLAB AS REQUIRED. WATER FILTRATION B2A B12 3/4" B1A B1A \• ,� A6 ,/ /' G9B G6C (G16A) , (REFERENCE ONLY) EXPIRES 10 -24 -2010 I Date . Signed: Jun 30, 2009 RECEIVED CITY OF TUKWILA JUL 048 2009 PERMIT CENTER SA Job No. 09217 7 P.1.1 10555 Old Sacramen ) dn D r d3l/► Phone (9 to �/A Fax .c rw �'' www saceng.c• G 1 /2" DRAWING LEGEND DETAIL DESCRIPTION SANITARY WASTE PIPING SAN GREASE WASTE PIPING —CRS —CW COLD WATER PIPING ---- HW - - -- HOT WATER PIPING FW FILTERED COLD WATER PIPING CD- CONDENSATE DRAIN PIPING - V- - VENT PIPING POINT OF CONNECTION TO EXISTING ----- (E)SAN - - - -- EXISTING SANITARY ------ (E)V - - - - -- EXISTING VENT (E)CW EXISTING COLD WATER PIPING EXISTING FILTERED WATER PIPING (E)FW (E)HW - - -- EXISTING HOT WATER PIPING ---- R - - --1- RELOCATED FIXTURE SCALE: 3/16 ":1' -0" Ca CCII 1 2 FILTERED CW FROM RELOCATED OVERHEAD CARBONATORS 3 4" FILTERED CW +24" TEE -OFF 1/4" EACH FOR RELOCATED CAPPUCCINO MAKER AND DUAL SOFT HEAT BREWER. TEE -OFF 3/8" EACH FOR ICED LATTE AND LATTE STEAMER. 3 4" FILTERED CW +36" EXTEND 1/2" EACH FOR RELOCATED FOUNTAIN ICE MAKERS AND RELOCATED B12 20 -VALVE ICE /BEVERAGE DISPENSER C B1B )3/8" FILTERED CW +30" RELOCATED FROZEN BEVERAGE DISPENSER SCALE: 3/16' =1' -0" EXISTING OFFICE EXISTING OFFICE 11 I I' 1 II.1 I I . I I 1 11 Z 1- z 0 m U EXISTING COVERED TRASH ENCLOSURE 0 11 11 I I I I 11 PLUMBING DEMOLITION PLAN PLUMBING ROUGH -IN PLAN x r EXISTING REST ROCS te a, I I I II > O EXISTING COVERED TRASH ENCLOSURE (G8 `3—R" r RELO w 0 (E)4= BACKROOM I am pm COFFEE 1 IN - x EXISTING STORAGE 0 1 � BACKROOM TANK PAta "A" 1# NITOR 11 07 G7 It / \ 1 3 "GW w 3 "FCO 0 . t I / / / / / 1/2" HW & CW +36" MOP SINK " DIRECT CONNECTION OP SINK EXISTING STORAGE FROM_ WATER SER_ CE I: TED WATER HEATS' / / / / / / ICI II I.ri 1 • S L 12 "HW &CW +8" 3— COMPARTMENT SINK, PRERINSE SPRAY/FAUCET _31 HAND SINK, G9E EXISTING STORAGE CONTAINER rrrnnmrTl A' (111111111111 1 2" CW +10" 3" DRAIN THRU FLOOR SLAB WATER CLOSET 2" WASTE 11-IRU FLOOR 16A HAND SINK' 1/2" HW & C\ '' +12" NEW UNISEX REST ROOM I I I I 11 II EXISTING STORAGE CONTAINER CD G16 1 2" & CW +23" 18.1./_2" LAVORA_T.ORY_. - EXISTING SALES r- AREA CASHIER 1 CASHIER rrrrrnhlr1T1'ITTir 1111111111111111111 . LLIJSIlLIULLUU� EXISTING SALES AREA L I XISTING REFAB OOLER 4 1 41 XISTING REFAB OOLER 2 NEW 1/2" CW NEW 1 -1/2" VENT SCALE: NO SCALE SCALE: NO SCALE PRE - FILTER SCALE: NO SCALE 1/2" CW 1 -1/2" VENT 2" WASTE FILTERED WATER TO ABOVE CEILING FOR CARBONATOR 1/2" DRAIN TO FLOOR SINK. NEW 1/2" HW L Y ' NEW 2" WASTE MOUNT FLUSH WITH FLOOR TYPICAL SINK INSTALLATION FINISHED FLOOR 1/2" HW— l'N t• i FLOOR GRATE TO BE FASTENED DOWN WITH SCREWS - NOTES A. FLOOR DRAIN COVER FLUSH WITH TILE OR FLUSH WITH CONCRETE FLOOR IN AREA WITH NO TILE SCALE: NO SCALE EXISTING HOT AND COLD WATER PIPING ABOVE CEILING, FIELD VERIFY LOCATION AND MATERIAL EXISTING VENT PIPING ABOVE CEILING, FIELD VERIFY LOCATION AND MATERIAL � � NEW TEE 400■ NEW SINK 4400 II/ N./ '�' EXISTING HOT AND COLD WATER PIPING ,,�� ABOVE CEILING, FIELD VERIFY LOCATION AND MATERIAL EXISTING VENT PIPING ABOVE CEILING, FIELD VERIFY LOCATION AND MATERIAL - TEE SAW CUT AND REMOVE FLOOR SLAB FOR PIPING INSTALLATION AS REQUIRED EXISTING WASTE PIPING, FIELD VERIFY LOCATION AND MATERIAL INSTALL REPAIR COUPLING (rw 2 ) INSTALL NEW TEE EXISTING WASTE PIPING, FIELD VERIFY LOCATION AND MATERIAL INSTALL REPAIR COUPUNG (rn' 2 ) INSTALL NEW TEE TYPICAL MOP SINK INSTALLATION FILTERED WATER TO ABOVE CEIUNG FOR ICE MAKERS, COFFEE BREWER, STEAMER MACHINE, CAPPUCCINO MAKER, AND AIR POT BREWER. EVERPURE WATER FILTER REFER TO SHEET Q6.1 FOR MORE INFORMATION WATER FILTER DETAIL (EXISTING). 1 .1.1 / i FLOOR SINK "FS -1" DETAIL 1" MINIMUM _^-HUB OUTLET CEILING DISCHARGE PIPE 3 P.1.1 6 P.1.1 GENERAL NOTES: 1. INDIRECT WASTE DRAIN LINES TO TO DISCHARGE ABOVE FLOOR SINK WITH AN AIR GAP OF AT LEAST MINIMUM OF TWICE PIPING I.D. AND NOT LESS THAN 1 INCH AIR GAP BETWEEN INDIRECT WASTE PIPING OUTLET AND FLOOD RIM OF FLOOR SINK, PER WPC 603.3.5, 608.5, 801.1. 2. HORIZONTAL DRAINAGE PIPING GRADE SHALL BE NOT LESS THAN 1/4 ":12 SLOPE, PER WPC 708.0. INDIRECT DRAIN UNE GRADE TO BE NOT LESS THAN 1/4 ":12 SLOPE, PER WPC 814.0. 4. FIELD VERIFY EXISTING REDUCED PRESSURE PRINCIPLE ASSEMBLY, A STAINLESS STEEL REDUCED PRESSURE BACKFLOW PREVENTER SHALL BE USED IN THE POTABLE WATER SUPPLY TO CARBONATORS. INSTALL OR REPLACE (IF NOT STAINLESS STEEL) WITH WATTS 009QT -Y2. ALL BACKFLOW PREVENTION DEVICES SHALL BE TESTED AND LABELED APPROVED BY A CERTIFIED BACKFLOW ASSEMBLY TESTING AGENCY AFTER INSTALLATION AND PRIOR TO FINAL PLUMBING INSPECTION, PER UPC /CPC 603.2.2 INDIRECT WASTE DRAIN LINE FROM CARBONATOR SPILLAGE -TYPE BACKFLOW PREVENTER SHALL DISCHARGE WITH AIR GAP TO FLOOR SINK, PER DETAIL 6/P.1.1 THIS SHEET. 6. THE DRAIN LINE OUTLET FROM THE CARBONATOR (G54) BACKFLOW PREVENTER SHALL BE TERMINATED TO FLOOR SINK, PER DETAIL 6/P.1.1 THIS SHEET. 7 THE DRAIN LINE OUTLET FROM THE 20 -VALVE ICE/BEVERAGE DISPENSER (B12) SHALL TERMINATED TO FLOOR SINK, PER DETAIL 6/P1.1 THIS SHEET. 1/2" 1 / 2 ✓ �/I� \�AMTROL ST -12 s K A10 • ~ WATER RISER SCALE: NO SCALE RPBP, WATTS 009QT -Y2. '\ '\ NUMBERED KEY NOTES: O EXISTING LAVATORY TO BE REMOVED. CONTRACTOR SHALL CAP EXISTING PLUMBING LINES AND PATCH SLAB FLUSH WITH EXISTING CONCRETE SLAB AS REQUIRED. O EXISTING WATER CLOSET TO BE REMOVED. CONTRACTOR SHALL CAP EXISTING PLUMBING LINES AND PATCH SLAB FLUSH WITH EXISTING CONCRETE SLAB AS REQUIRED. NG 600LB ICE MAKER (G6A) TO REMAIN. ® EXISTING UTILITY SINK TO BE REMOVED. CONTRACTOR SHALL CAP EXISTING PLUMBING LINES AND PATCH SLAB FLUSH WITH EXISTING CONCRETE SLAB AS REQUIRED. EXI i PLUMBING CONTRACTOR SHALL ROUTE THE 3" GREASY WASTE UNE TO EXISTING GREASE INTERCEPTOR. A10 Ic)c, - A15 EXISTING WATER HEATER (G8) TO BE RELOCATED WITH HI /LOW STRAPS, UPPER AND LOWER 1/3 OF UNIT. REFER TO ARCHITECTURAL DWGS FOR FURTHER INFORMATION. EXTEND AND RECONNECT EXISTING PLUMBING SERVICES TO NEW LOCATION. EXISTING WATER PURIFICATION SYSTEM (G11) TO REMAIN. EXISTING CARBONATORS (G54) AND ASSOCIATED PLUMBING TO BE RELOCATED. REFER TO ARCHITECTURAL DWGS FOR FURTHER INFORMATION. EXTEND AND RECONNECT EXISTING PLUMBING SERVICES TO NEW LOCATION EXISTING FOUNTAIN, FCB AND COFFEE STATIONS TO BE RELOCATED. REFER TO ARCHITECTURAL DWGS FOR FURTHER INFORMATION. EXTEND AND RECONNECT ASSOCIATED PLUMBING SERVICES TO NEW LOCATION. NEW FLOOR SINK (FS -1) TO BE INSTALLED, PER DETAIL 6/P1.1 THIS SHEET. 2" VENT RISER, CONNECT TO EXISTING HORIZONTAL 2" VENT ABOVE CEIUNG, FIELD VERIFY. EXISTING FLOOR SINK TO REMAIN. EXISTING SINK TO BE REMOVED. CONTRACTOR SHALL CAP EXISTING PLUMBING LINES AND PATCH SLAB FLUSH WITH EXISTING CONCRETE SLAB AS REQUIRED. WATER FILTRATION B2A B12 3/4" B1A B1A \• ,� A6 ,/ /' G9B G6C (G16A) , (REFERENCE ONLY) EXPIRES 10 -24 -2010 I Date . Signed: Jun 30, 2009 RECEIVED CITY OF TUKWILA JUL 048 2009 PERMIT CENTER SA Job No. 09217 7 P.1.1 10555 Old Sacramen ) dn D r d3l/► Phone (9 to �/A Fax .c rw �'' www saceng.c• G 1 /2"