Loading...
HomeMy WebLinkAboutPermit D09-103 - RREEF PROPERTIES - REROOF AND DECKRREEF PROPERTIES 12610 INTERURBAN AV S EXPIRED 07-21-10 D09 -103 Parcel No.: 0004800003 Address: 12610 INTERURBAN AV S TUKW Suite No: Tenant: Name: RREEF PROPERTIES Address: 12610 INTERURBAN AV S , TUKWILA WA Owner: Name: C/O EPROPERTYTAX INC Address: DEPT #207 , PO BOX 4900 85261 Phone: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Contact Person: Name: KEN HENDERSON Address: 9720 39 AV CT SW , LAKEWOOD WA 98499 Phone: 253 255 -9737 Contractor: Name: MCDONALD & WETLE ROOFING INC Address: 9420 39TH AVE CT SW , LAKEWOOD WA 98499 Phone: (503)6670175 Contractor License No: MCDONWR944DW DESCRIPTION OF WORK: REMOVE EXISTING ROOF SYSTEMS AND INSPECT WOOD DECK TO MAKE REPAIRS IF NECESSARY, INSTALL NEW ROOF INSULATION AND COVER BOARD, 3 -PLY FELTS AND 1 -PLY WHITE CAP SHEET, NEW SKYLIGHTS, AND SHEET METAL. Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 Citylif Tukwila $420,000.00 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D09 -103 Issue Date: 07/01/2009 Permit Expires On: 12/28/2009 Expiration Date: 03/17/2010 Fees Collected: $6,472.83 International Building Code Edition: 2006 Occupancy per IBC: D09 -103 Printed: 07 -01 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: City o,Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: Permit Number: D09 - 103 Issue Date: 07/01/2009 Permit Expires On: 12/28/2009 End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of thi permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the e performai►ce of work. I am authorized to sign nd obtain this development Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 N JU Date: 1 1 Date: D09 -103 Printed: 07 -01 -2009 Parcel No.: 0004800003 Address: Suite No: Tenant: 12610 INTERURBAN AV S TUKW RREEF PROPERTIES 1: ** *BUILDING DEPARTMENT CONDITIONS * ** S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D09 -103 ISSUED 06/18/2009 07/01/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Application of roof coverings with the use of an open -flame devices requires a separate permit from the Tukwila Fire Department located at 444 Andover Park East, Tukwila, Washington, 98188; telephone - (206)575 -4407. There shall be not less than one multi- purpose portable fire extinguisher with a minimum 2 -A 20 -B:C rating on the roof being covered or repaired. (IFC 105.6.24, 1417.3) 12: An operational permit is required for the storage and use of LP -gas and operation of cargo tankers that transport LP -gas. (IFC 105.6.28, Chapter 38) 13: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 14: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 D09 -103 Printed: 07 -01 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: .PI 6q Date: d / Print Name: 1 (J& L , ad/e/. doc: Cond -10/06 D09 -103 ordinances governing or local laws regulating Printed: 07 -01 -2009 Company Name: Mailing Address: • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hl uktivila.ma.us E -Mail Address: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** / �� King Co Assessor's Tax No.: Site Address: /DI (O l D /'e Suite Number: Tenant Name: RR L-E f PAr P e- S Property Owners Name: 5 Mailing Address: S,4nti� Name: ku1) gefi)d '/Q _/ JJ Mailing Address: ? T4 c O 3 9 /� I ) e , C 7 .� Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: E -Mail Address: Building Permit No. )O City City Contact Person: E -Mail Address: Fax Number: H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh State State State State o Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) SITE LOCATION 000tt b -bba3 Floor: New Tenant: ❑ Yes ❑ .. No Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: v< $� �J �"' ? 7 �.a�l Gds, Y? ? City 9� / State Zip Fax NumberOS3 9-9Da..- GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record City Day Telephone: Fax Number: Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Zip Day Telephone: Page 1 of 6 • Valuation of Project (contractor's bid price): $ 49 9 OOO..I HAApplications\Norms- Apphcat ons On Line \2009 ApplIcattons \I -2009 - Permit Application.doc Revised 1 -2009 bh BUILDING PERMIT INFORMATION - 206 - 431 -3670 Existing Building Valuation: $ Scope of Work (please provide detailed information): /4u sp L f moo il,e.c_k 4- A.).1 i vi Ake /QeiditIAs , i= fiecess Ai Ry, /45 // W4174 ( 0 S4 lee r A il eu) _ <ky I f 4 /"S i iv e SI e /ll i--.h L Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑. Yes jgt . No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor 2 Floor 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck • Valuation of Project (contractor's bid price): $ 49 9 OOO..I HAApplications\Norms- Apphcat ons On Line \2009 ApplIcattons \I -2009 - Permit Application.doc Revised 1 -2009 bh BUILDING PERMIT INFORMATION - 206 - 431 -3670 Existing Building Valuation: $ Scope of Work (please provide detailed information): /4u sp L f moo il,e.c_k 4- A.).1 i vi Ake /QeiditIAs , i= fiecess Ai Ry, /45 // W4174 ( 0 S4 lee r A il eu) _ <ky I f 4 /"S i iv e SI e /ll i--.h L Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑. Yes jgt . No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW OR AUTHOR ED A GENT: Signature: Date Application Accepted: Print Name: teeitAi e*( O 4.1 Mailing Address: / fdD 37M A / le. e-1" ,S /U ael lb lv) H:\ApplicationsWorms- Applications On Linc\2009 Applications \I -2009 - Pcrmit Application.doc Revised: 1 -2009 bh Day Telephone: 1-4/(e City Date: (� ' F a.5s ?'37 ids yy�� S ta t e Zip Date Application Expires: LAO) Staff Initials: Page 6 of 6 Parcel No.: 0004800003 Permit Number: D09 -103 Address: 12610 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 06/18/2009 Applicant: RREEF PROPERTIES Issue Date: Receipt No.: R09 -00921 Initials: User ID: Payee: JEM 1165 ACCOUNT ITEM LIST: Description MCDONALD & WETLE ROOFING, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1550 6,472.83 Authorization No. BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: // vw.ci.tukwila. RECEIPT Account Code Current Pmts 000/322.100 000/345.830 640.237.114 Total: $6,472.83 Payment Amount: $6,472.83 Payment Date: 06/18/2009 01:29 PM Balance: $0.00 3,920.20 2,548.13 4.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 06 -18 -2009 COMMENTS: c! ',/{ D ?e 6 00_e6 04 A04. Ad-6 0( tAiik-tv-vA7 G A r 01, ke4 9 _/a do r Z lose ® -{-� Clevv Pte-6 nn 0 Ilk' •-f tJ � O tiJ e kcfv'eca -R s leefSsits iello-.-s. 1J al r -a r y , 5 I AA. IC ket%fI / rot. 'K- Special Instructions: Date Wanted: Z y l Projec Ko .04 Type of Inspection: Address: 12_6 %a l 1 "'`''h Date Called: 'K- Special Instructions: Date Wanted: Z y l a.m Requester: Phone No: INSPECTION NO. Approved per applicable codes. Inspecto : Receidt /No.: INSPECTION RECORD Retain a copy with permit Dat 'Date: r-- b09... a 3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION izr- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Eli Corrections required prior to approval. �C 6� REINSPECTION FEE RE U ED. Pri r to ins /7- pection, fee must be pa d• t 6300 Southcenter Blvd., uii a 100. Gall to schedule reinspection. Projec Type of Inspection: \ Addre 1 24640 -kpi iJ b Date Called: 1, _.., Special Instructions: Date Wanted: ... .o � �a.rit �n Reque Phone No: _1 tL igoc— INSPECTION RECORD Retain a copy with permit INS' ECTION NO. PERMIT NO. CITY OF TIJ!WILA BUILDING DIVISION I 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6tNCLA `N5 -- C' a■AX- tge i — Insp #tor: 0.00 REINSPECTION F aid at 6300 Southcenter E REQUIRE 3 lvd., Suite 7A- Prior to inspection, fee must be 00. Call to schedule reinspection. Re ipt No.: !Date: Proje R CcC 4P Ty ( • o l Address: a 2(o{b t' Lli►..A - 1 1P Date Called: Special Instructions: Date Wanted: ' .m Requester: Phone sge Z (o 1 - ..2, 673 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Pe" r/ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3 7 0 Approved per applicable codes. O Corrections required prior to approval. COMMENTS: A rt eA I Z pect Date: g )(16il— a ❑ $6 0) REINSPECTION FE ` ' EQUIRED.Prior to inspection, fee must be pad Et 6300 Southcenter Blv , Suite 100. Call to schedule reinspection. 'Date: ReceiQt �o.. Pro ect: 11 i` p aPf IFS Type of Inspection: � 'xf . ?oaf S. Address: /ACS /v.�✓let7e /b9 /�i/J Date ailed: 01/2 -/0 �j- Special Instructions: Date Wanted: Requester: Phone No: x5 2 t /— s� 67 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION'. Vs 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: ac-/o 3 (206)431 -37 Date: A / EINSPECTION FEE R) QUIRElXPrior to inspection, fee must be 6300 Southcenter Blv ., Suite 100. Call to schedule reinspection. Date: Project: /4 ' 4". e . 1.-- te a P. Type of Inspection: . ,2 of �- vS \ Address: ' /li/MA/ /02 G / 0 2 ,Date Called: Special Instructions: Date Wanted: S — d P a.m Requester: Phone No: :,-Z _ G/ ° INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: p Inspe 5 44 i / / • /jog / •fae $ • .00 REINSPECTION FEE " EQUIR ' . Prior to inspecti . n, fee must be aid at 6300 Southcenter Bl •., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: S P ect: R RAE r PQoPCRc ►dc- Type of Inspection: S x4P (IC3V 4Oc) r- ('- Address: 12-C,10 j-6 VitI/COA Date Called: U S Special Instructions: �- ' Date Wanted: .., — 7 -30 - 5 Caitt p.m. Requester: Phone No: 253 LG (_ (967 3 INSPECTION NO. ❑ Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 be 9 - i o PERMIT NO. (206)431 -3 0 Corrections required prior to approval. COMMENTS: p /1, S, _ 4 rP...4t 10 (141 + 1 bf s 6.4 Dade- 3 HAAA') EINSPECTION FEE RlUIRED. Pf for to inspection, fee must be a 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt o.: IDate: Pro' ci. Type of Inspection: F l Dr 4 /el � Address: y�- /2-D -i11.C�J /.1 Date Called: Special Instructions: - -2�-Ji • R g E. Date Wanted: `� p.m. Requester: Q �' 1 Phone No: 2 53- 241 -g' Inspector: a u fr AAA ,,_. Date: , Z - el' . DOy'- <03 INSPECTION RECORD Q ( Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3q7 D Approved per applicable codes. O Corrections required prior to approval. COMMENTS: \o f L P AS D if s 1t ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: el. . t �r.a_...�.. Pro Pro . e KK r.,-rd V Type of Inspection: Address: ! 1 2: (O(0 1_ -.A.Tt1 u ) Date Called: Special Instructions: om i t., A. O • - % -J k1d ` °'l Date Wanted: 7 /....4 6 - a �, • 7• � P.m. Requester: Phone No: 2 e3- 2.4/ — e673 INSPECTION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit J0g-103 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ie 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: I (Date: Inspecr: /\ , El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 7 Project: Type of Inspection: (vad` iaa° F Address: _ 12 W v - —Aref v l.24 &/ Date Called: Special Instructions: Date Wanted: ` 2. _ D ,,�,. p.m. Requester: Phone -- 241 --fs ( 3 Oo - 103 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. t CITY OF TUKWILA BUILDING DIVISION (-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 p Approved per applicable codes. El Corrections required prior to approval. COMME 5: $60.00 REINFECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pro )c Et ,a�D / Type of p n ? dJ tsis?..X. Address: /-• dal 0 //4W?/l. 11, Date Called: Special Instructions: Date Wanted: 7- 2 -. Q p.m. Requester: Phone No: 3 -2 /- cG7 1665- /o 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2d6 431 -3 J Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: A' a& = Rove) P Type of Inspection: ^-.. .4 T iii.% Date Called: Address: _— /2 & /v 1a/ Ml / . Special Instructions: Date Wanted: 7 - .2 l cis a.m.. p.m. Requester: Phone No: 2 .-? --Q6 - 7 ' INSPECTION RECORD Retain a copy with permit 2 - /d 3 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 E Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: i„ <ya,l6V " 4 012 r/ P ni s, /-K t Spector: / h 1 13 7 -: e/5 inspection, 6 .00 REINSPECTION FEE R. QUIRED. Prior to fee must be id at 6300 Southcenter Blvd , Suite 100. Call to schedule reinspection. ? eipt No.: (Date: Proect;, Type of Ins ecti n: Addiess: / a 6 t o . A/-/enf, GA, Date Called: tr Special Instructions: Date Wanted: 7- 2 3 - d p.m. Requester: Phone No: -23 3- -0 7 5 INSPECTION NO. _ j • INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Stew A 5 - 4p 1, Inspector: 'Date: $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Prod t: Rc.Fr . Pao Type of Inspection: G\ootc StheM - tkiM Address: 1 2-(o 10 -- Cr SAP ∎zo v to Date Called: 5 ) Special Instructions: Date Wanted: I 1 !] p.m. Requester: Phone No: -- S _ �e1 86 INSPECTION RECORD Retain a copy with permit I09- 1 0 3 IN PECTION NO. PERMIT NO. U CITY OF TUKWILA BUILDING DIVISION e- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1..(206)431 -3 7 Approved per applicable codes. Corrections required prior to approval. S COMMENTS: p 4 1 S P R to'4 A pAA J 1.4,A) -- Date /�' El $60.00 R NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: a Project P' v elm € f Type f ectiQn: f_. i s ' Address: t2 ( �Af e1riIb01 Date Called: Special Instructions: 8 Date Wanted: -7 -14 Alt U p.m. Requester: Phone'_ 3 s " G9 ` VO '73 5 O -103 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION %' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 r x $ 60.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcente Blvd., Suite 100. Call to schedule reinspection. ceipt No.: Date: Approved per codes. ❑ Corrections required prior to approval. COMMENTS: P A /� Pro : Type of Inspection: Address: /aG /0 1N /',?r' 6,0A/ Date Called: Special Instructions: ( Date Wanted: 7- i3- 05 p.m. Requester: Phone No: d,S. ?--2 / 5'G7 3 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISI ON 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit gas % 5 PERMIT NO. '- i (206)431 -3q7 Corrections required prior to approval. COMMENTS: Inspector: Date: LI $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: Type o i�9Je�io ) �C I -4-(1-kiy Address: 2---.t 0/b-M Date Called: Special Instructions: p Date Wanted: 7 -to -05 Requester: Phone No: 753 - 2. (o x(073 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION L Do g- fv2 PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: f,r /I 2. Date: El $60.00 REINSPE ION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Ca(l to schedule reinspection. Receipt No.: IDate: Project � // / �Q 14 j l i /, > / In ec Ion: Typgg sp 7'i�/ XJ / / er ft l ,-- Address: 6/0 .� / /2 � /I. 4 A., 4 _ Date Called: Special Instructions: Date Wanted: <r p.m. Requester: Phorsep ;` 2C /- 7C73 n p`,- /o3 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. I CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -347 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 01/ TJ /t /E Date: g� � : 9 - El $60.00 REINSPP CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Pro.'e� r r) UZ� S Type of �yspect n:� 1 Address: 12 (41/0 f G i Ak Date Called: Special Instructions: Date Wanted: q .`�,. l .. (� i p.m. Requester: Phoge' :3 .... 2 (0 ' -5 Dig./03 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: D i/ 'C: � G A/r Date: ❑ $60.00 R SPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: Type of Inspection: 00/4 rye Q A414 Address: 1 a u t t o 1 r fP rivicha ri Date Called: Special Instructions: (thail 641;/1 g / 5 7 .....31:9zet. e' 1 Date Wanted: 'r" 3- a.m. p.m. d�. Requester phone No: INSPECTION RECORD hz Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 9 -- 1 PERMIT NO. (206)431 -3 pp roved per applicable codes. D Corrections required prior to approval. COMMENTS: Date: 7-7- r $ .00 REIN ° ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 outhcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: Date: , Project � rb l , e /��lG- /' �►�! . .s Type of Inspection Pre --- / tee 4 °0 Address: Z. � 0 /<) s�l��l�✓ 6.4y Date ailed: A�� • Special Instructions: Date Wanted: 7_, �� Q � .‘41.13:1- p.m. Requester: Phon;:w 2,55 1 , 737 INSPECTION RECORD Retain a copy with permit INSPECTION O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 009- PERMIT NO. (206)431 -3670 El Approved per applicable codes. Zoo orrections required prior to approval. COMMENTS: .2 vtP 1 As e `idi 4 S'iJu -. C d 77/4. e . (l -P. —g-A e Date: n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ~ I t / Permit No., 1)'i Plan review approval is subject to a jand oiijntrs. Approval of construction dime . nqt aphorize � any adopted p r the violati of an ado ed code o or r • inane; 'J cei t S - , ni of approviel Copy and conditions is acknowledged: , ‘k By r/3 O 6.; .z.M4) v t ws g; -4 Tatev 1 / /i/ q . ,-;, City Of lUkwila o BUILDING DIVISION Q a .' o El ❑ rn! • iMan= vv■ • 0 Y6' rid( tN 4l t Asa X54 I zl U cS (he v. eA611 O a l N94.14.Ii red .NrAn.tvt or 400 t h'1 F r 3303 BIM BLVD. SAM -Bp WEEToDAET COSTA MCA _ FL Q °) SEPARATE PERMIT REQUIRED FOR: 0 Mechanic a Fa Electrical Fil Plumbing +: s- 12, Gas Piping ity of Tukwila 8 WI DING DIVISION RREEF MANAGEMENT TUKWILA, WA ) f g 3 IQ o iiii/e ;7 qo w /I 5 ,30 EJ 12610 INTERURBAN A 2009 ROOF REPLACEMENT - BUIL -New TUKWILA COMMERCE PARK TUKWILA, WA CODE IOEP FOR ED APPROV JUN 2 5 2009 s 5# r_ R CITY OF TIJKI�MLA JN _ ?; 8 2009 RMIT CENTER F 1103 1- RS12610 ARA- LEA; O SKYLIGHT ® HVAC UNIT ❑+ VENT ® SWAMP COOLEF ® EXHAUST FAN Of* ANTENNA # SATELUTE DISH ® ROOF HATCH IN ROOF DRAIN = SCUPPER kwila ING msloN 02/09/09 r Ub /Vb /LVV7 V6.Ji rm O''.i4 JL' +04:J McDONALD & WETLE 24 GA PREFINISHED GRAVEL STOP ''-'11111 COpy SET IN MASTIC LAP & SEAL 3" MIN r•- N AIL 6" STAGGERED LAP & SEAL 3" MIN U 3 „ TU KWI LLA 3° FACE GRAVEL STOP FLASHING wJ VVVL /VV IL e'9! immirf/.fp1ir i► iii ■i ii{iiiiiiiiii,viwiiii i.vi r1 ii i•i +{ .iarr h r Ll LI 1 rrt-rn I I J J 1, I II RECEIV D CITY OF TU LA JUN,"" Y 8 2009 PERMIT CENTER CONTINUOUS CLEAT FASTENED 24" O.C. C ODE REVIEWED FOR COMPLIANCE APPROVED JUN 2 5 2009 City of Tukwila BUILDING DIVISION I DATE.-owosjo4 06/0$/2009 09:33: I A X . L34924b45 McDONALD & WETLE NEOPRENE GASKETED ,-SLOPE SCREW 24" Q.C. 24 GA PREFINISHED COPING. CONTINUOUS CLEAT W /STANDING SEAM 10' 0.C. FASTENED 24" O.C. TYP COPING TUKWILLA I4JUU / DATE 06/05/09 VO /VO /LVVJ VO.JI rmA ::40404404J wjvvui,vv 1'L Mc]DONAlD & WETLE 6 „ 24 GA PREFINISIIED GRAVEL STOP SET IN MASTIC LAP & SEAL 3" MIN NAIL 6" STAGGERED LAP & SEAL 3" MIN 4' • r • MOW * ' E MM 4111116 ■ TM 11 1 - 1 1 I I 1 1 111 CONTINUOUS CLEAT FASTENED 24" O.C. 6" FACE GRAVEL STOP FLASHING TU KWI LLA 1 DATE:06 /05/09 VO /VO /CVVJ VO. 31 rt5A - J004044O4J McDONALD & WETLE 26 GA PREFINISHED — COUNTER FLASHING FASTEN 24 O.C. TYP COUNTER FLASHING TU KWI LLA IQ.J VVV4 /VU I DATE O6 /05/09 06/08/2005 08:38 FAX 7U34yZ464� IQJVUV7 /uUIZ McDONALD & WETLE NEOPRENE GASKETED FASTENER 24° O.C. 5 TYP SLEEPER CAP TUKWILLA PEEL & STICK UNDERLAYMENT 24 GA PREF1NISHED CAP I DATE06/05 /09 Vti /Vtf /LVVi Vtl: Aft �V,144G43 McDONALD 4 LB LEAD COLLAR 1/4" MIN CLEARANCE WETLE LE STAINLESS DRAW BAND TYP VENT BASE TUKWILLA 10 MIN. SEALANT TYP 24 GA. GALV. RAIN COLLAR 1/4" MIN CLEARANCE NAIL 3" 00 STAGGERED I,110006 /0012 DATE-06 /05/09 06/08/2009 08:39 FAX 5034924645 McDONALD & WETLL 24 GA PREFINISHED DRIP \ SET IN MASTIC LAP & SEAL 3" MIN \ FASTEN 6 STAGGERED 4' - TYP GUTTER TUKWILLA 24 GA PREFINISHED GUTTER W /STRAPS 24" Q.C. LAP, SEAL & RIVET 10' 0.C. FASTEN 24" O.C. -5' 7' tJOVU ( /VO1'L DATE O6 /05/09 -4P Thickness (nominal) 1/2" • 25/32" - 1" 1-1/2" 2" Board sizes 2'x 4'; 4' x 4'; 4' x 8' 4'x 4'; 4' x 8' ' 2' x 4'; 4' x 4'; 4' x 8' 2' x 4'; 4' x 4 2' x 4'; 4' x 4' Boards/Unit .. 2' x 4' = 168; 4' x 4'; 4' x 8' = 60 4' x 4'; 4' x 8' 7 ; 95 • 2' x 4' = 84; 4' x 4'; 4' x 8' •=t 46 , 2' x 4' = 56; 4' x 4' 7.7z 30 2' x 4'; 4' x 4' = 42 SQuareS/Unit 1- 2' x 'V = 13.40; - 4' x 4' = 9.60; _1 2' x 4' = 6.72; 2' x 'V = 4,48; 2' x 'V = 3.36; 4' x 4' = 15.20; 4' x 8' = 19.20 4' x 4' = 7.36; 4' x 4' = 4.80 4' x 4' = 6.72 4' x 8' = 30.40 ; 4' x 8' = 14.72 Deflection at specified min. load,. max Irv; he$ s0.75" (5.19mm) No ASTM Data • 50.42" (s Ilmm) • No ASTM Data s8.21" (s5mrn) Flute Span 1 5/8" (40mm) 2 5/8" (67mm) 2 5/8" {67mm) : 4 3/8" (i 1 Irnm) 4 3/8" (111mm) R-V'alue 1.3 1.9 2.5 3.8 5 l CC2 0 C) > Wm 0 CC >uj 12. Luo fr 0 Structodek® High-Density Product Offerings GAF MATERIALS CORPORATION GAt =ULAN ' Ply 4 roofing felt is on , d •. a strong glass :a' tat coated with the s1 e ly n: halt, and 's Jusluned with optimum porosity In assure sound, watertight m .mn.rar:rE. GAFGL.AS PI\' 4 is used as a ply felt in the construction of built -up roofs. a is designed for use in all cllrnat : zc.se:. and Is apprcpriate for use a Lase sheet, as a ply felt, and In the construction of flashing rrlembranes. • High tensile strength and a high degree of dimensional stabiLlty. resulting in a roof cyst rr With greater resistance t:. selitting and cracking • (m:tinui of the felt escape of air :roper asphalt tra, :.on ,he time of • P:.snhai'. _ oaring provides high eq ce i`f rmoistitre resistance • rssstan —for use in UL Class A rated assemblies Vied up,ift resistance — selectee roofing assemblies with 'GAFGLAS Ply 4 felts FN Class 1-180 when insta oveI concrete decks -1i Corn ^.ra• 7'09 34 o Meets ASTM D -2178, Type IV specifications ® Meets requirements for applica- tion in all climate zones o Rolls out flat for easy installation o Typical system guarantees available for up to 15 years, select system constructions available with up to 20 year guarantee coverage. Rot Size 5 squares (531 gross sq.ft.) (49.3m Rot Length 161.8' (49.3m) Rol: Width 39.375" (1.0m) Approx. Roll Weight 34.9 lbs (20.0kg) CO REVIEWED COMPLIANCE APPROVED � JUN 2 5 1009 City of Tukwjla BUILDING Meets ASTM D2178, Type IV FM Approved ICC ESR 4 1274 Miami -Dade County Product Control Approval UL/ULc Listed www.g °H 1b 3 raV C J CITY I OFTUKIIMLA JUN'. t 8 2009 PERMIT CENTER GAl'G. AS Mineral Surfaced Cap She : .s an asphalt- coated glass W th ei al Surfaced Cap Sheet is rise..a as the surfacing ply in the .•;13()r applied built -up roofs a as a tr_p el� in base flashing (�f . -: • ....IiE Coi y ''roduct Control Approval P :;cu :t Approval ,Lls n 'r;,.; 32 ® Durability —glass base resists the effects of moisture on the roof system. © Granule surface provides an ultra- violet protective surface. *Code approvals --UL Class A, B, or C membrane constructions are available. ® Aesthetically attractive; requires no additional surface coatings. • System guarantees are available for up to 20 years. Roll Size 1 square (107 gross sq.ft.) (9.9m') Roll Length 32.6' (9.9m) Roll Width 39.375" (1.Om) Approx. Roll Weight 68 lbs (30.8kg) www.gaf.com • GA tOV EFIA:.3 A IO.\1 GLAS #7S .;asf ShFe is a premium roofing base sheet constructed with a strong glass mat that is coated on both sides to assure a closed - sheet design to prevent asphalt bleed- through. The sealed sheet also serves as ar effective flame retarder for the )ppli atic •) <<f torch- applied m : ified bite . e , membranes. GAFGLAS#75 Base Sheet is engi- ilCe ed for use: ir• t he construction of GA built -up and RUBE.ROID( modified bitumen roofs It is suitable for nailable specifications, such as plywood, whom bleed- th - ough is a concern. C4C.. 1 - ✓pc is C J \chided :I? x +274 CD.:r ,y r• Con1lol Anpr3val to als ;orrorat,on 7/08 38 PZLE Permit Igo, COPY • Extra strength for excellent nail - holding ability. Superb tensile strength and resilience and no bleed through, thereby reducing risks of splitting and cracking of membrane. a Will not rot, curl, or shrink; dimensionally stable for improved membrane performance. a Designed to meet UL Class A ratings. a Rolls out flat for easy installation. ® System guarantees are available for up to 20 years. Roll Size 3 squares (320.1 gross sq.ft.) (29.7m Roll Length 97.5' (29.7m) Roll Width 39.375" (1.0m) Approx. Roll Weight 68 lbs (30.8kg) crnow JUN: f 8 2009 PERMIT CENTER Dal- .0 °03 Description RUBEROID MOP FR membrane is a premium, heavy duty, fire - retarding modified bitumen membrane manu- factured to stringent GAF Materials Corporation specifications. Its core ,s ;trcJ i, resilier ncen -woven p1 ie ;,r , that ct , sited 'rrth Lit nlif' ; Iy f: e ret'°, •• SBS )oiymcr ! odified (.:sphialt and 'nee • 2itt• ntint'ra' lrz rules .� _OF .0 L.) IM DP i .? , designed or new rlxifirig and reroofing ipplicafiis where long-term roof , :ern p,rformanc is specified. .dvantaeies :a ?I:tee s are ov.-ilable for LIC to ?ci years.. - No coa :ii icy requii i'.r for Class A raiincr: 'rom UL and f MRC. cos elf. 'r :tive —the ir.st:3lled cost o RU;3E :UID MOi • f. is less than most single -ply systems on Vie ma 'r et today. • ' . ighiw. i1 :t- - -install; ci s_ premium roof designs Neigh less, thtjn 3 pounds Per square foot. Resilent RUBEROID MOP FR's Heavy weight polyester mat, core sftow s it to resist spliis and tears line its pliability ant: elongation cr ca rat :tr 7y;iical Physical Pri'p- es Pi &pert�e ^— Test Method Tensile E. ;. '.gth @ OF :•ail ), lbfjjn ASTM D5147 -': ngati. : • :QM: ( nom 'y, ASTM D5147 , :w Tempt +ature Flee tali,, (max.), F ASTM D5147 'ear Strencith (nom.), Ibf ASTM D5147 'irrnensi:r.al Stability. '7, ASTM D5147 r' ac n :t Hera shet'rs I Advantages (Continued) • Durable — specially formulated modified asphalt gives RUBEROID MOP FR lasting performance. • RUBEROID MOP FR is backed by GAF Materials Corporation, a company with over 100 years in the roofing business. • Available with black or white granules. Applicable Standards • UL ULC Approved for use in construction of Class A B. or C roof systems.' • FM Approved - BOCA Listed: Report No.359 • SBCCI P`. T & ESI Listed • Dade County Product Approval • New York City MEA 160 -91M • Meets ASTM 0 -6164. Type II • Meets CGSB- 37- GP -56M 'See GAFMC Application and Specification Manual or UL Directory for specific approval. Product Data (Approximate) Roll Size 1 square (111 gross sq. 11 )(10.3m Product Thickness 0.160' (4mm) Reinforcement 250 gram polyester mat Roll Weight '102 lbs. (46kg) Values 123 50 -22 123 <1 CAPUCHINS CORPORATION Chem L wate. versa • mina' on grz, iuidt PIB i ' ChemCurb'" System Penetration Seal has been keeping roof penetrations ./' =:r 15 years. The ChemCurb System replaces old -style metal pitch pans with • ;ter components and pourable sealants that can usually be installed in under 10 ever require flashing or mechanical attachment. ChemCurbs are designed for use modified bitumen, asphalt and coal tar B.U.R. They are also specified for PVC, EPDM, =inq!e ply roofing (must use Chem Link TPO Primer with TPO.) When installed . forms a durable, waterproof rubber seal around penetrations of any size. The ChemCurb System is sold as a kit or as separate components for larger jobs and unique shapes. Our inside sales staff will work with you on any specific project ensuring that the customer receives the best penetration seal in the industry. • ernllnkinc.com After 15 years of success with our traditional ChemCurb System we are expanding our line to include the new E- Curbs'". Both economical and efficient, the 3 ", 6" and 9" E - Curbs "interlocking slip fit technology" allows for quick assembly and easy installation. CHEM LINK Advanced Architectural Products Contractor Driven, Product Data Sheet EnergyGuard' Polylso Insulation Description EnergyGuard" Roof Insulation Board is made of organic/glass facers bonded to a core of isocyanurate foam. Advantages • High insulation value - Excellent "LTTR" value compared to any other FM Class I rated products of equivalent thickness. • FM Approved - Subject to the conditions of approval as a roof insulation when installed as shown in the current edition of the Factory Mutual Research Approvals Guide. • Environmentally safe - Uses EPA accepted blowing agents. • Lightweight - Lighter than most other insulating products offering comparable thermal resistance; as much as five times lighter in weight than many other materials with the same R- value. • Excellent dimensional stability. • Low water permeability - lower overall perm rating than many conventional insulation boards. • High moisture resistance and no capillarity; is stable and maintains its physical and insulating characteristics. • Easier handling and faster to install - Because it is light weight, this material is easier to handle on the job site and installs faster. Easier cutting in the field provides the installer with simplified fabri- cating on the roof deck. Minimizes on-the-job damage. Uses • EnergyGuard" Roof Insulation is designed for use over structural roof decks where "R" values of 6.0 or higher are required, along with comprehensive U.L.- and FMRC approvals. • When properly installed, it is suitable for use under built -up, modi- fied bitumen and most single -ply roofing systems. • Refer to the application specifications in the current Membrane Manufacturer's Application and Specifications Manual for proper installation procedures. Limitations and Potential Fire Hazard • EnergyGuard" Roof Insulation is a non - structural, non -load bearing material. It is not designed for direct traffic usage unless adequately protected. • EnergyGuard "' Roof Insulation should be stored dry and protected from the elements. No more insulation should be installed than can be completely covered with roofing on the same day. • As unprotected polyisocyanurate will burn, fire safety precautions should be observed wherever insulation products are used. • Direct torching of modified bitumen roofing to EnergyGuard" Roof insulation will present a fire hazard. A properly installed fiber glass base sheet MUST be used over the insulation. Code Compliance • Listed by Underwriters Laboratories for use as part of a Class A, B or C Roof Covering. See U.L. Inc. Roofing Materials and Systems Directory for details. • Subject to the conditions of approval as a roof insulation when installed as shown in the current edition of the Factory Mutual Research Approvals Guide. • Mechanical attachment of roof insulation is the most dependable method of attachment to steel decks since it minimizes lateral move- ment and wind blow -off. • For details, consult Factory Mutual Loss Prevention Sheet 1 -28, 1- 29, / -28R, 1 -29R and current Approval Guide. • Federal Specification I-1N -1- 1972 /ASTM Cl2.89. 31 City of Tukwila - ' IOIJ Thermal and Ph y r , IV. xit nom Flute Thickness* LTTR Spanability lacteal rtlmm Value** Inches mm 1.0 25.4 6.0 2 '/, 66.7 1.1 27.9 6.6 2' /. 66.7 1.2 30.5 7.2 2 '/. 66.7 1.3 33.0 7.8 3'/. 93.3 1.4 35.6 8.4 4 '6 III . 1.5 38.1 9.0 4 Y. Ill. 1.6 40.6 9.6 4 '6 111. 1.7 25.4 10.3 4 '/, III I. 1.8 45.7 10.9 4'6 III. 1.9 48.2 11.5 4 5, 11 I. 2.0 50.8 12.1 4 '/, III. 2.1 53.3 12.8 4 '/, III. 2.2 55.9 13.4 4 '/, III. 2.3 58.4 14.0 4 II I. 2.4 60.9 14.7 4 Y. III. 2.5 63.5 15.3 4 '/. III. 2.6 66.0 15.9 4 'I. 1 1 1 . 2.7 68.6 16.6 4 '/, 1 11. 2.8 71.1 17.2 4'/. III. 2.9 73.6 17.9 4 '/. III. 3.0 76.2 18.5 4 '6 III. 3.1 78.7 19.1 4 ' /. III. 3.2 81.2 19.8 4 III. 3.3 83.8 20.4 4 7. II I. 3.4 86.4 21.1 4 '/. 111. 3.5 88.9 21.7 4'/. III. 3.6 91.4 22.4 4 '/. III I. 3.7 93.9 23.0 4 '/. I I I. 3.8 96.5 23.7 4'I. III. 3.9 99.1 24.3 4 ' I . 1 1 1 . 4.0 101.6 25.0 4 'I: 114.3 'Other thicknesses available upon request. * *Long Term Thermal Resistance Valves provide a 15 year time weighted average in accordance with CAN/DLC 5770- (1) Note: Physical and thermal properties shown are based on data obtained under controlled laboratory conditions and arc subject to normal manufacturing tolerances. Typical Physical Properties Test Properly Value Method Water Absorption. % by Volume -- 2 hrs. 1.5 max. Dimensional Stability Change 7 days ® 158°F (70'0. 90.100% RH Lengthwise <2% Crosswise <2% Compression Resistance" 10% Consolidation -psi (kPa) 20 (1381 nom. Laminar Tensile Strength -psi (kPa) 4 (28) Moisture Vapor Transmission*° <I perm (57.5 ng/(Pa•s•m -1 Flame Spread .•. <75 Service Temperature * Also available in 25 psi (172 kPa) ** Foam core only. ***These numerical ratings are not intended to reflect hazards presented by these or any other material under actual fire conditions. WARNING: DO NOT EXPOSE TO OPEN FLAME OR EXCESSIVE HEAT. MAY BURN IF IGNITED. IF IGNITED, EXTINGUISH COMPLETELY. NOTE: REPAIR ROOF LEAKS PROMPTLY TO AVOID ADVERSE COND:7IONS. INCLUDING MOLD. REVIEWED FOR CODE COMPLIANCE APPROVED � JUN 2 5 2009 - 100 to 200 °' ( -73 to 93 °C) ww ASTM C 209 ASTM D 2126 ASTM D 1621 ASTM C 209 ASTM E 96 ASTM E 84 RE EIVED CITY OF TU L► Li of 1 8 2009 PERMIT CENTER Pro c 1105i 4'x4' Label 03" to 1.0" AA 1.0" to I S' A 1.5" to 2.0" B 2.0" to 23" C 23" to 3.0" D 3.0 "to3S" E 3.5" to 4.0" F 4'x4' Label 03" to 1.5" x IS" to 2.5" y 2.5" to 35" Z Description EnergyGuard" Tapered Polylso Foam Roof Insulation has a thermal- ly efficient polyisocyanurate core bonded between organic/glass facers. It is readily available in the two most popular and efficient tapers, 1/8 inch per foot (I%) and 1/4 inch per foot (2 %). Advantages • Properly designed and installed EnergyGuard" Tapered Polylso Foam Insulation Systems virtually eliminates ponding water. • High thermal efficiency. • Easily installed with mechanical fasteners, hot asphalt or loose laid in a ballasted system. • Low point and letter codes are designated on each board. • Engineering design hoard lay -outs are available from your plans and field verified dimensions. Uses • EnergyGuard'" Tapered Polylso Foam Roof Insulation is designed for use over structural roof decks to provide slope to drain and to provide thermally efficient insulation. • When properly installed, it is suitable for use under built -up, modified bitumen and most single -ply roofing systems. • Refer to the application specifications in the current Membrane Manufacturer's Application and Specifications Manual for proper installation procedures. Limitations and Potential Fire Hazard • EnergyGuard" Tapered Polylso Foam Roof Insulation is a non- structural, non -load bearing board. It is not designed for direct traffic usage unless adequately protected. • EnergyGuard Tapered Polylso Insulation should be stored dry and be protected from the elements. Once properly loaded at the job site, remove factory wraps and cover with a breathable tarp. • As an unprotected polyisocyanurate will bum, fire safety precau- tions must be observed wherever any insulation products are used. • Direct torching of modified bitumen roofing to EnergyGuard "' Tapered Polylso Foam Roof Insulation will present a fire hazard. A properly installed fiber glass base sheet MUST be used over the insulation. • These tapered systems are designed to provide a top surface of slope. Each board is manufactured to exact thickness specifications. GAF cannot be held responsible for field conditions such as actual building dimensions and deck deflection. Installation Suggestions for Tapered Systems Although each tapered system is different, here are some suggested methods for installing a Tapered Polylso Foam Roof Insulation system efficiently. 1. Verify building dimensions and drain locations with the Tapered Foam Roof Insulation Shop Drawing. Discrepancies should be reported to GAF prior to shipment. 2. Verify that the proper number of truckloads and piece quantities have been received on the job site. 3. Determine the area to be completed that day. 4. Measure the distance from the drain to the perimeter where the shop drawing indicates full 4 feet x 4 feet insulation boards. Verify that the system will meet the drain piece. 5. Start installing the tapered system utilizing full 4 feet x 4 feet boards. Work from the drain and finish the area where the shop drawing indicates field cutting. Product Data Sheet 19 Product Data Sheet EnergyGuare Tapered Polylso Insulation 6. When more than one layer of insulation is utilized, all vertical board joints should be staggered, preferably by 1/2 board. 7. Cover the insulation with the complete membrane system the same day. Code Compliance • Listed by Underwriters Laboratories for use under Class A, B, or C Roof Covering. See UL, ULC Inc. Building Materials and Systems Directory for details. • Approved component of Factory Mutual System Class I, Insulated Steel Deck Construction when secured to the steel deck with mechanical fasteners (such as DRILL•TEC'" roof insulation fastener system). • Mechanical attachment of roof insulation is the most dependable method of attachment to steel decks since it minimizes lateral movement and wind blow -off. • For details, consult Factory Mutual Loss Prevention Sheet 1 -28, 1 -29, 1 -28R, l -29R and Approval Guide. • Federal Specifications HH -I -1972. WARNING: DO NOT EXPOSE TO OPEN FLAME OR EXCESSIVE HEAT. MAY BURN IF IGNITED. IF IGNITED, EXTINGUISH COMPLETELY. 32 Tapered Board Label Designations I/8" (I%) Slope (Tapered 1/8" to the foot 1/4" (2%) Slope (Tapered 1/4" to the foot) NOTE: REPAIR ROOF LEAKS PROMPTLY TO AVOID ADVERSE CONDITIONS. INCLUDING MOLD. Typical Tapered Layouts Product Data Sheet EnergyGuard' Tapered PolyIso Insulation a i t _ t Two Way Tapered System (Crickets Optional) Four Way Tapered System with Perimeter Drain AA A 8 C D E F AA Typical Cross Section 1/8" slope (tapered 1/8" to the toot) 33 52 " B C 1 t Modified Two Way Tapered System with Constant Edge Thickness (Crickets Optional) \t/ ,/\+ /4 \ / Four Way Tapered System with Variable Edge Thickness D E ...umM111111111111111110 1 1 /2" 1" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 4 1/2" 5" 5 1/2" 6" 6 1/2" 7" Note: Consult FM Loss Prevention Data Sheets 1 -29, 1-49 for specific perimeter and corner fastening details. F 7" Due to ongoing testing programs and changes in FM Global requirements, the number of fasteners and their placement are subject to change without notice. Consult current FM Approvals Guide and Loss Prevention Data Sheets 1 -28, 1 -29 and 1 -29R for approved fastener density for EnergyGuard Roof Insulations. 1 GAF Certified Contractor Online Support System FILE COPY 0 rr t ° v Permit No. k Form GNOA Pl » Welcome McDonald & Wetle Roofing Inc! "Helping the best and most supportive contractors build their business and avoid hassles" I Print No Cost Print GAF Notice of Award Registration Your Warranty Reference Number is: 403676, Please retain it for your records. Owner Information (Mailing Address) Owner Name: gateway olympia inc. Address: C/O RREEF management co. a delaware co. 12720 gateway dr. suite #200 City: tukwilla, WA. Actual Building Location(On /y if different from Mailing Address) Building Name: tukwilla commerce park Address: 12610 interurban ave. south bldg. D Installation Information City: tukwilla, WA. State: WA Steep Slope Squares: 0 Low Slope Squares: 583 Product Information Owners /Representative's Contact Information Contact :: greg coleman Fax Number :: 206 -241 -7512 Email Address :: gregory.coleman @rreef.com PI -- General Contractor's Name and Address : Company Name : : N/A Specifier's /Consultant's Name and Address • Company Name : : west coast roof consulting Address :: 3303 harbor bvld. suiteDl3 City : : costa mesa State :: CA Zip Code : : 92626 ( Enter Another Warranty Phone: 2067 State: WA Phone: Zip Code: 98168 Country: USA Total Squares: 583 FILE COPY Permit No. Page 1 of 4 aAFMMALS CORPORATION YC•ifY• Back a Close CO APPROVED JUN 2 5 2009 City of Tukwila WING DIVISION Email: > 1tt •c.i v i:. v CITY OF TUKIML■ JUN:, 8 2009 PERMIT CENTER httns:// webl0. roofexcellence.com/cgi bin/wspd cgi.sh/WService= wsbrokerl/lead/warform 6/16/2009 r liAI Lemma contractor online support system rage z Contact : : mark curry Phone :: 714- 545 -7663 Email Address : : mcurry @westcoastrc.net Building Description Usage, Etc. : : commercial Building Height :: 30 Length :: 550 Width :: 139 Number of Buildings* : : 1 Roof Access : : roof hatch Type of Guarantee Requested : 10 year NDL PROJECT DETAILS : No Start Date • Please provide anticipated start date : 7 -01 -09 Completion Date : : 7 -21 -09 Specification Number : : I -B -4 -M Has an Architectual Information Services Cut Sheet Spec been provided :: No Roof Slope : : 1/4" Complete Tearoff Deck Type : : Wood - -- Wood Deck: Indicate Type : : plywood - -- Wood Deck: Indicate Thickness :: 1/2" Multiple Decks? : No Vapor Barrier : Optional : No Top Side Venting : . No All Insulations supplied by GAF? : Yes Product Type : httns: / /web10. roofexcellence .com /cgi- bin/wsnd cgi. sh/ WService= wsbrokerl/lead/warform 6/16/2009 I GAF Certified Contractor Online Support System Page 3 of 4 : EnergyGuardT'" ISO Thickness : . 1.7" Attachment : : Mechanically Fastened Product Type • : EnergyGuard'' ISO Thickness : . 1.7" Attachment • : Mechanically Fastened Product Type • : WFB Thickness : : 1/2" Attachment : : Mopped BASE FLASHING : Yes Lineal Feet of Flashing : 1650 Specification : rubberoid 20 and cap Wall Construction : : Non - Combustable 1st Ply: : Ruberoid® 20 2nd Ply : : GAFGLAS Mineral Surfaced Cap Sheet Interply Number of Plies : : 3 Product :: Ply 4 Interply Attachment : : Mopped Membrane Cap Sheet • : GAFGLAS® Mineral Surface Cap Sheet Surfacing • httns://web10.roofexcellence.com/cgi-bin/wsnd cgi_sh/WService= wshrnkerl /lean /warfnrm All Ailnno UAt Certitred Contractor Online Support System Page 4 of 4 : Granules Asphalt Type : : Type III Asphalt Manufacturers Manufacturer's Name : : apoc Describe in detail the preparation and the installation of the roofing system : Please tell us what you are planning to do : : remove existing roof systems and inspect plywood and replace any damaged areas,install 2 layers 1.7" iso mech. attached and mop on 1/2" cover board, mop on 3 plys type 4 ply and mop on cap sheet, replace all skylights with new and install new kynar sheet metal Your Name : ken henderson E -mail Address * : ken @mcdonaldwetle.net I Print No Cost I Print WARRANTY NO: 403676 I Enter Another Warranty Close https: / /web 10.roofexcellence.com/cgi- bin/wspd cgi.sh/ WService = wsbrokerl /lead/warform 6/16/2009 Lea^ ®Br" C® MATRIX 307 P Repair &MalntenancePrvducts � "" , � remium Asphalt Primer es Excellent - Bond For Asphalt Roof Systems Description ,t t®' MATRIX"' 307 Pre Asp ialbPrimer is a general purpose, asbestos -free foundation coating for all types of asphalt -based rocnf rsmaterials, e.g., hot - mopped or cold - applied asphalt coatings, roof cements, and asphalt- baseVroof and flooring adhesives. MATRIXTM 307 has an excellent penetration rate that promotes a tough bond for coating and adhesives; strength and flexibility to accommodate temperature - related expansion and contraction of the roof system. • Excellent penetration rate — promotes a tough, weather - resistant bond for coating and adhesives. • Strength and flexibility — accommodates temperature - related expansion and contraction of the roof system. • Easy Application ...sprayer, brush or roller — maintains excellent low temperature flexibility. • Recommended for use in systems by major membrane manufacturers, including GAF Materials Corporation and U.S. Intec. Uses MATRIXTM 307 Premium Asphalt Primer has an excellent penetration rate that promotes a tough, weather - resistant foundation coating for: • Concrete and masonry roofs, walls or floors prior to the use of asphalt cutback adhesives • Metal edging and flashing, asphalt or weathered composition roofing prior to the application of hot - mopped or cold applied built -up roofing materials • Undercoating for LeakBusterTM Aluminum Roof Coatings or Asphalt Roof Coatings and EmulsiontREQEIVED • Gypsum surfaces CITY OF TUKIliu Approvals & Certification MATRIXTM 307 Premium Asphalt Primer is listed and approved by the following agencies or code bodies: Underwriters Laboratories (UL), Factory Mutual (FM). Meets or exceeds the requirements of ASTM D-41 Asphalt Primer Used in Roofing, Damp Roofing and Waterproofing. Surface Preparation APPROV H' 18 2009 All surfaces to be primed must be clean, dry and free from any foreign matter, such as oil, grease, dirt or debris that could inhibit the bonding capabilities of the primer. Sweep or wire brush (metal surfaces) and remove oil, grease, dirt or other foreign material that could inhibit bonding. On existing roofs, inspect roof deck condition; moisture in old roof may indicate need for roof repair. Contact GAF or U.S. Intec Contractor Services for details on cutting out and repairing blisters, buckles and raised edges for a smooth surface. Che ,r,� .. s V..Ileys and vents and repair as needed. Use MATRIXTM 203 Plastic Roof Cement fo r- • _ -_ ;_.. �_:. ,;: le � s. c- Application Application Rate: Typical application rate is 1 /2 gallon per square, varies Irith textaiNf atifadeRtilbe primed. Drying time is 4 - 8 hours between coats. Material Preparation: Stir well before application. City of Tukwila Application Method: Apply primer with a roller, brush or sprayer coverin� t 11itf & O tJ ` ','n's per 100 square feet. Spray: A Graco 45.1 pump or equivalent is recommend t- equipment manufacturer for optimum psi, spray tip size, length of hose and number of spray guns to achieve uniform coat. Brush: Apply smooth, even coat, using parallel strokes for uniform coat. If first coat is completely absorbed, apply a second coat. Roller: Apply smooth, heavy coat, using parallel strokes for uniform coat. Precautions Compatibility & Limitations: Do not use on wet or damp surfaces or on surfaces previously covered with coal tar products. On concrete decks, previous use of wax/resin curing compound may inhibit bonding. 1201 - (�) Temperature Range: Apply only when temperatures are 45 °F (7.2° C) and rising. Cold weather will cause product to stiffen, making application difficult. Store 24 hours at room temperature prior to application. Do not heat container or attempt to thin this product. Not recommended for application on substrates that exceed 140 °F (60° C). Storage /Handling & FIRE WARNING: MATRIXT"" 307 Premium Asphalt Primer is COMBUSTIBLE and should always be kept away from heat, open flame and any source of ignition. Observe normal safeguards for storing and handling of this product prior to and during application. Do not allow primer to freeze. Important Repair leaks promptly to avoid adverse effects, including, but not limited to, mold growth. Clean Up Keep containers covered when not in use. Clean equipment and over spray with kerosene, mineral spirits or petroleum naphtha. Clean hands with waterless hand cleaner. Caution MATRIXTm 307 Premium Asphalt Primer contains petroleum distillate. Do not thin. Ventilation — use with adequate ventilation and close containers when not in use. If TLV (Total Level of Vapor) is exceeded, respirators are required (NIOSHA/MSHA). Inhalation of high vapor concentration may result in headaches and/or dizziness. Remove individual to fresh air and administer oxygen if breathing is difficult. If breathing has stopped administer artificial respiration, keep victim warm and order emergency medical attention immediately. Eye Contact Rinse immediately with water for 15 minutes and seek medic al advice. Personal Protection — Irritation may result from prolonged or repeated contact with skin. Wear chemical resistant gloves, protective goggles and protective clothing, if needed. Fire Protection — MATRIXTM 307 Premium Asphalt Primer is COMBUSTIBLE and should always be kept away from heat, open flame and any source of ignition. Waste Disposal — Empty containers must be disposed of in an approved landfill in accordance with local, state and federal regulations. DATA REPORTED ARE BASED ON AVAILABLE INDEPENDENT AND IN -HOUSE RESOURCES. BUILDING MATERIALS CORPORATION OF AMERICA RESERVES THE RIGHT TO CHANGE OR MODIFY, AT ITS DISCRETION AND WITHOUT PRIOR NOTICE, ANY OF THE INFORMATION, REQUIREMENTS, SPECIFICATIONS OR POLICIES CONTAINED IN THIS DOCUMENT. Limited Warranty Building Materials Corporation of America (BMCA) warrants that, at the time of delivery, the product contained herein shall conform to BMCA's specifications therefore THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. It is Purchaser's sole responsibility to determine the suitability of this product for any particular application. Recommendations made by BMCA are believed to be reliable, but BMCA makes NO WARRANTY OF RESULTS to be obtained. Purchaser's sole and exclusive remedy, regardless of the theory on which a claim may be based (including, without limitation, negligence, contract, breach of warranty, strict product liability or misrepresentation) is the replacement of this product, or, in the alternative, the original purchase price of this product. In NO event shall BMCA be liable for INCIDENTAL, CONSEQUENTIAL, SPECIAL, INDIRECT OR PUNITIVE DAMAGES. Purchaser must notify BMCA, in writing, of any claim at 1361 Alps Road, Bldg. 11, Wayne, NJ 07470; Attention: Contractor Services Dept. within 30 days of discovery of any alleged manufacturing defect. Purchaser must allow BMCA to inspect this product as installed as part of the claims procedure, or, at BMCA 's option, must provide BMCA with sample cuts taken from the roof. No agent or employee of BMCA or anyone else is authorized to modify the terms of this limited warranty. Physical Properties PRODUCT DATA: MATRIX"' 307 Premium Asphalt Primer Weight 7.4 lbs (3.36 kg) per gallon VOC (max): 350 grams/liter Solids content: 85% by weight minimum Sizes: 3 gaV11.4L or 5 gaU18.9 L or 55 gallon/208.2 L For Application Questions GAFMC Contractor Services at 1-800- 766 -3411 or visit www.gaf.com U.S. Intec Contractor Services at 1- 800 - 624 -6832 or visit www.usintec.com Recommended By Major I Manufacturers, Including: OAF CORPORATION /N1ECI Manufactured By: Building Materials Corporation Of America 1361 Alps Road, Wayne, NJ 07470 ©2004 Building Materials Corporation Of America 06/04 USICC113 Knight- Ue:otex :: Structodek Low -Slope Hoofing Products Knight rchitcx Fih,tvho:trd RiDcrf "s : 5:stems Single -Ply Systems EPDM TPO & PVC / PVC Based Re -Roof Bituminous Systems BUR (Built -Up) Modified Bitumen (MB) Hybrid Spray loam Systems Spray Foam f ;SPUR) Coating Systems Liquid Membranes Structodek® Stn_iczodek y Cant Sc rib / Tapered Edge Cant Strip / Tapered Edge for TD • iL O�tttt QQ LOW-SLOPE RO PP :nR StruptHeik ;;p';.. Cant Strip / Tapered Edge. v.inE <E - i J 8:1':' i DOCi,MENTATION I GREEN BUILDING I REQUEST SAMPLE I PRESS I HOME Knight-Celotex Structodek® As an insulation board, coverboard or re- roof /recover board, Structodek® High - Density Roofing Board is the answer for low -slope applications and systems. Structodek® is not only an integral roofing system component; It also makes roofing easier with physical properties that generate structural rigidity and dimensional stability. The fiberboard composition of Structodek® possesses natural bonding qualities, resulting In superior adhesion capabilities. Adhesive tightly grasps the fibers of Structodek® without causing excess absorption providing a solid and secure roof system which bonds very well with many asphalt, coal tar, and cold process adhesive products. The lightweight nature of Structodek® is better than heavier alternatives and will keep the roof load below the specified maximum weight. Structodek High- Density Product Offerings ya Click chart for larger image Struc:todek® Approvals List Structodek® general product properties: FILE CO ii f, r. 4. . ' Cr" 1�� ��I S' :btn•�1 2S9' !6 , 7n; 11:9 l;l:., _.. ". 2' . •f 2. 1c. • All board thicknesses have a 5 7% water absorption value (7% max per ASTM C208 -95 ('01) a All board thicknesses have been approved as components in UL Class A Systems (consult UL Guide for approvals) n All board thicknesses have been approved as components of 1 -60 and 1 -90 systems per FMCR Standard 4450/4470 (see FM Guide for approvals) • Structodek® is available in coated one -side to reduce asphalt bitumen absorption as well as coated six- sides, providing maximum protection on all e:lposed surfaces. Meets the needs of today's professional Available in a variety of thicknesses, coating coverage options and panel sizes, Structodek® meets the needs of today's roofing professional. Benefits of Structodek® include: o Approved in UL Class A rated roof systems reillabs Contact Us Need More Info? Information Form Page 1 of 2 Customer Service / Technical Support 1 -866- 926 -0622 Ask the Expert Fill out Technical Form More Products More Knight - Celotex Fiberboard Products Visit: www.knightcelotex.com REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 5 2009 City of Tukwila ILDING DIVISION c tT O nLA JUN 18 2009 PERMIT CENTER tIQ httn• /vnxnz✓ len 0ht r•nm /nrnrinntc /ctntntnrdPk acne Kit ? /7M0 Knight- (e)otex :: Structodek Low -Slope Rooting Products Page 2 of 2 o Structurally rigid and dimensionally stable board easily handles heavy foot traffic and wheeled loads a Superior adhesion without excess absorption o Contributes to thermal insulation with R- values ranging from 1.3 to 5.0 a Lightweight and easy to install, without the irritating fiberglass dust of glass mat Faced gypsum board o Easily handles hot asphalt, non - blistering a Cuts wit a standard utility knife Systems in which Structodetc® is approved: a Single -ply (thermoplastic /elastomeric) o Modified bitumen (cold /hot mopped) o Built -up roofing systems (asphalt/coal tar) o Hybrid systems o Self adhered o Spray foam (SPUR) a Liquid membranes Company Info j Links I Terms & Conditions I Privacy Policy I Terms of Use I Site Map Copyright © 2009 Knight Industries, LLC. All rights reserved. httn : / /www. Icniaht'eintexrnnfino / nm /nr lime /etriir`t, 1, �a,.v The data below is constant for each Drill.Tec ASAP' 3S Fastener. Thread Diameter: .220 Head Diameter: .435 Head Style: #3 Phillips Truss Head' Coating: CR -10 Plate Material: Galvalume° steel ' #3 phillips bit included in each carton. Recommended By Major Manufacturers, Including: GAF MATERIALS CORPORATION 458D 458E 458F 458G 458H 4581 458J 458K PRODUCT DESCRIPTION Wks n I•Tec ASAP` 3S (Assembled Screw And Plate) is designed g.� ®q to secure insulation to steel and wood substrates. The Dril ASAP' 3P is Drill•Tec Standard #12 Roofing Fastener assem with Drill•Tec 3" Galvalume Plate. The Drill•Tec ASAP" is available in lengths from 2 1/4" to 8" stock. Longer lengths are assembled to order. The Drill•Tec ASAP' 3P is Factory Mutual and Dade Count approved. APPLICATION The Drill•Tec ASAP' 3S must penetrate steel decks a mini 3/4 ". Drive the fastener until the screw head is seated se with very rigid insulation boards. watch for the plate to dimp e. For the fastest, most effective method of installation, use the TallBoy or ShortBoy" tool. Note: Be careful not to overdrive the fastener and fracture the skin of the ! nsulation. Fastener must be tight enough so that the plate doesn't turn. For steel decks, Factory Mutual requires that the fastener penetrate the deck at the top flute. 3 1/4" 3 3/4" 5 °' 6" 7" 3" 250 3" 250 458L 8" 4" 250 15 lb 16 lb 17 lb 18 lb 19 lb 21 lb 23 lb 25 lb 26 lb TEC'FtECE1VED CITY OFTU OMIA JUN 1 8 ?ON Do PERMIT CENTER DRILL -TEC ASAP® 3S ASSEMBLED SCREW AND 3" STEEL PLATE Fast Facts The Drill•Tec ASAP° is designed to secure insulation to steel and wood decks. FEATURES & BENEFITS •The Drill•Tec ASAP° 3P greatly reduces installation time and labor costs. •A Drill•Tec Standard #12 Roofing Fastener assembled with a Drill•Tec 3" Galvalume• Plate. •No special installation tool required. •Steel plate sits flat on Dens -Deck° and other high density insulations. COATING Drill•Tec CR -10 corrosion resistant coating exhibits less than 15% red rust after 30 Kesternich cycles. CR -10 coating exceeds F.M. Approval Standard 4470. PLATES & ACCESSORIES For best installation results, use a variable speed 0 -2500 rpm screw gun. For the fastest, most effective method of installation, use the TalIBoy` Installation Tool. •w I OS D 1LL'TEr ASAP® 3S ASSEMBLED SCREW AND PLATE SPECIFICATION The fastener will be a Drill•Tec ASAP® 3S with a thread diameter of .220. The fastener must have 12.5 threads per inch and a 30' spade point. Also, the fastener must be heat treated per specification OMG -1. The Drill•Tec ASAP® Fastener will be assembled with a Factory Mutual approved, Drill-Tec 3" Galvalume' Plate. The fastener must be Factory Mutual approved and made in the U.S. COATING REQUIREMENT The fastener will be coated with the Drill•Tec CR -10 corrosion resistant coating. When subjected to 30 Kesternich cycles (DIN 50018), the fastener must show less than 15% red rust and surpass Factory Mutual Approval Standard 4470. APPLICATION The Driil-Te,_. ASAP` must penetrate steel decks a minimum of 3/4 ", Using a screwshooter, drive the fastener the screw head is seated securely; with very rigid insulation boards, watch for the plate to dimple. Note: Be careful not to overdrive the fastener and fracture the skin of the insulation. Fastener must be tight enough so that the plate doesn't turn. Factory Mutual requires that the fastener penetrate the steel deck at the top flute. PHYSICAL DATA Head Diameter: .435 Head Style: #3 Phillips Truss Thread Diameter: .220 Packaging: 250 /carton EXAMPLE DRILL•TEC ASAP 3S LENGTH SELECTION PROCEDURE FOR STEEL DECK 1. If applicable, determine thickness of existing roofing material. 2. Add thickness of new insulation. 3. Add 3/4" minimum fastener penetration. 4. If odd size requirement, always size up in length, not down. See example. Example Existing Roofing: 3/4" New Insulation: 1/2" Min. Embedment: 3/4" Total Fastening 3 " Range The proper ASAP® 3S for this example is 3 1/4". Existing Roofing: New Insulation: Min. Embedment: 3/4" Total Fastening Range Use this format to calculate your correct fastener size. GAF Contractor Services 1 -800- 766 -3411 www.gaf.com USI Contractor Services 1-800-624-6832 www.usintec.com ©2004 Building Materials Corporation Of America, 1361 Alps Road, Wayne, NJ 07470 4/04 COMDT201 Manufacturer Address Wayne, NJ 07470 Florida Phone Number. 800 - 7664411 California Phone Number 800..424-9300 no information is available, the space must be marked to indicate tha SECTION 1 - MATERIAL IDENTIFICATION AND INFORMATION COMPONENTS - Chemical Name & Common Names (Hazardous Components 1% or Greater. Carcinogens 0.1% or greater) Non - Hazardous Ingredients Total SECTION 2 - PHYSICAL/CHEMICAL CHARACTERISTICS Boiling Point Vapor Pressure (mm Hg and Temperature) Vapor Density (Air = 1) Solubility in Water Appearance and odor. Dark color, viscous liquid, petroleum odor when thoroughly stirred SECTION 3 - FIRE AND EXPLOSION HAZARD DATA Flash Point and >100°F Auto-Ignition Method Used NFPA ethrlausher Media: Dry chemical. roam water fog ,. Special Fire Fighting Pry None Unusual Fire and lion Ham. Petroleum based compounds can float In water Optional MATERIAL SAFETY DATA SHEET BMCA Leak Buster"' Matrix TM 307 Asphalt t4 Primer Label co VI t4 Materials Corpo►ationn ofAmerica' 1361 Alps Road pi' ^ r 313° F ND ND Insoluble '400' F 100 Flammability Limits in Air % . Volume OSHA 174 Matrix 307 Standard Asphalt Primer Identity (Trade Name As Used On Label) TAPCO #410 MSDS Number' 1086 CAS Number* N/A Mixture '� _ 1 _ 1- �TT7T_`fli OR Date Prepared: 5/22/02 re CE = _ �. -1- - Prepared By' P. Hennings NOTE: Blank spaces are not permitted. If any item is not applicable, r JUN 2 5 2009 Specific Gravity (H20 =1) Melting Point OSHA PEL >1.0 ND E vaporation Rate (Butyl Acetate = ND Water Reactive Non LEI. 0.9% • ' r1• Ia fill r ; ION CITY 0 TU 009 PERMIT CENTER UEL 6.0% Page 1/2 MSDSGAF MATERIAL SAFETY DATA SHEET BMCA Leak Buster "" MatrixTm 307 Asphalt Primer Label Manufacturer Building Materials Corporation of America Address 1361 Alps Road Wayne, NJ 07470 Florida Phone Number. 800 - 766 -3411 California Phone Number 800 - 424 -9300 NOTE: Blank spaces are not permitted. no information is available, the space m SECTION 1 - MATERIAL IDENTIFICATION AND 100ppm COMPONENTS - Chemical Name & Common Names (Hazardous Components 1% or Greater Carcinogens 0.1% or greater) ACGIH TLV OTHER LIMITS RECOMMENDED Ceiling of 10m. /M3 Max hr., 1, 800 mg/M3 SECTION 2 - PHYSICAL/CHEMICAL CHARACTERISTICS Matrix 307 Standard Asphalt Primer Identity (Trade Name As Used On Label) TAPCO #410 MSDS Number 1086 CAS Number N/A Mixture Date Prepared: 5/22J02 rev 02/04 Prepared By' P. Hennings If any item is not applicable, or ust be marked to indicate that. INFORMATION Boiling Point Vapor Pressure (mm Hg and Temperature) Vapor Density (Air = 1) Solubility in Water 313° F ND ND Insoluble Appearance and Odor: Dark Color, viscous liquid, petroleum odor when thoroughly stirred SPec+fic Gravity (H20 =1) Evaporation Rate (Butyl Acetate = Water Reactive Melting Point >1.0 ND ND Non SECTION 3 - FIRE AND EXPLOSION HAZARD DATA Flash Point 1ana> oo° F method t� Me NFPA :. Media: Dry chemical team, water fog Special Fire Fighting Procedures. None Optional Auto - Ignition T >400' F Unusual Fire end Explosion Nazards" Petroleum based compounds can Goat In wager Flammability Lints in Airs . Volume OSHA 174 La 0.9% UEL 6.0% Page 1/2 MSDSGAF SECTION 4 - REACTIVITY HAZARD DATA STABILITY Stable Unstable HAZARDOUS POLYMERIZATION May Occur _X Local Exhaust Special SECTION 5 - HEALTH HAZARD DATA lace in dosed container for . ro..r dis al. Conditions: Keep from heat, sparks, open flame To Avoid Incompatibility (Materials to Avoid): Acids, caustics, chlorinated hydrocarbons oxidizers. Hazardous Decomposition Products: Nitrogen oxides, carbon oxides __X Not Occur Conditions To Avoid NA PRIMARY ROUTES OF ENTRY: X Inhalation _X Skin Absorption CARCINOGEN LISTED IN: _ NTP IARC Monograph Haz --x Ingestion raph OSHA X Not Listed HEALTH Acute. Itching, unconsciousness, dizzy, dry skin, nausea, headache HAZARDS Chronic: Difficult breathing (cancer studies inconclusive); Signs and Symptoms of Exposure: Repeated/continuous exposure can cause: Chemical pneumonia, liver/kidney damage. Medical Conditions Generally Aggravated by Exposure: Repeated /continuous Large exposure can aggravate emphysema. EMERGENCY FIRST Alp PROCEDURES - rge amounts may need Immediate emergency treabnent Eye Contact Flush eyes for 15 minutes with clean water, GET MEDICAL ATTENTION. Skin Contact wash wrilh soap and water. Get medical care if irMation persists. Inhalation: Get to fresh air, administer oxygen or artificial respiration. Ingestion: DO NOT INDUCE VOMITING, GET MEDICAL. ATTENTION QUICKLY. SECTION 6 - CONTROL AND PROTECTIVE MEASURES Respiratory Protection (Specify Type): Organic vapor cartridge if in an enclosed area. Protective Gloves: Impervious to solvents, to avoid sticky and soiled hands. VENTILATION TO BE USED Other Pro tective Cl p g X Other (Specify) Avoid vapor concentrations. othing and Equipment Lon sleeve shirt and long pants preferred, but not required. Eye Protection: Safety goggles _X Mechanical (General): If inside Hygienic eleased: Use non - sparking tools with absorbent material (limestone), shovel up and Waste Disposal Methods: RCRA incineration, regulated material. Consult local, state & federal regulations for permitted land fill disposal or Precautions to be Taken in Handling and Storage: Use in well - ventilated area, store in DRY, cool area. Other Precautions and/or Special Hazards: DO NOT HEAT FOR APPLICATION. Wash contaminated clothing. MSDS NO. 1086 PAGE 2/2 HAZARDOUS POLYMERIZATION May Occur _ X _ Will Not Occur Conditions To Avoid NA STABILITY Stable X Unstable Conditions: Keep from heat, sparks, open flame To Avoid Incompatibility (Materials to Avoid): Acids, caustics, chlorinated hydrocarbons oxidizers. Hazardous Decomposition Products: Nitrogen oxides, carbon oxides I SECTION 5 - HEALTH HAZARD DATA PRIMARY ROUTES OF ENTRY: _X Inhalation CARCINOGEN USTED IN: lion X_ Skin Absorption ___X_ Ingestion Not Haz _ _ NTP _ IARC Monograph OSHA X Not Listed HEALTH Acute: Itching, unconsciousness, dizzy, dry skin, nausea, headache HAZARDS Signs and Symptoms of Exposure: Repeated /continuous exposure can cause: Chemical pneumonia, liver/kidney damage. Medical Conditions Generally Aggravated by Exposure: Repeated /continuous Large amounts may need immediate exposure can aggravate treatment tmphysema. EMERGENCY FIRST AID PROCEDURES - Lar emergency treatimhent Eye Contact: Flush eyes for 15 minutes with clean water, GET MEDICAL ATTENTION. Chronic: Difficult breathing (cancer studies inconclusive). Skin Contact wash with soap and water. Get medical care if irritation persists. Inhalation: Get to fresh air, administer oxygen or artificial respiration. Ingestion: DO NOT INDUCE VOMITING, GET MEDICAL ATTENTION QUICKLY. SEC T ION 6 - CONTROL AND PROTECTIVE MEASURES Respiratory Protection (Specify Type): Organic vapor cartridge if in an enclosed area. Protective Gloves: Impervious to solvents, to avoid sticky and soiled hands. VENTILATION _X Local Exhaust TO BE USED S pecial X Mechanical (General): If inside Other Protective Clothing and Equipment Long X Other (Specify) Avoid vapor concentrations. ng sleeve shirt and long pants preferred, but not required. Hygienic Work Practices: Wear gloves and eye goggles to prevent irritations, wash hands with soap & water or waterless cleaner SECTION 7 - PRECAUTIONS FOR SAFE HANDLING AND USE/LEAK PROCEDURES Steps to be Take if Material is Spilled or Released: Use non - sparking tools with absorbent material (limestone), shovel up and •l ace in closed container for . ro er cis . osal. Waste Disposal Methods: RCRA incineration. regulated material. Consult local, state & federal regulations for permitted land fill disposal or Precautions to be Taken in Handling and Storage: Use in well - ventilated area, store in DRY, cool area. Other Precautions and/or Special Hazards: DO NOT HEAT FOR APPLICATION. Wash contaminated clothing. MSDS NO, 1086 Eye Protection: Safety goggles PAGE 2/2 GAF MATERIALS CORPORATION SECTION 1: PRODUCT AND COMPANY INFORMATION Asphalt 2 Reactive 0 Special Hazards OSHA HAZARDOUS: Yes X CHEMICAL NAME Stoddard Solvent Leak BusterTm Matrix 307TM Asphalt Primer N/A N/A PRODUCT NAME: TRADE NAME: CHEMICAL NAME / SYNONYM: CHEMICAL FAMILY: N/A MANUFACTURER: GAF Materials Corporation ADDRESS: 24 -HOUR EMERGENCY PHONE (CHEMTREC): 800 — 424 — 9300 INFORMATION ONLY: 800 — 766 — 3411 PREPARED BY: Corporate EHS APPROVED BY: Corporate EHS 1361 Alps Road, Wayne, NJ 07470 NFPA Hazard Rating 2 SECTION 2: COMPOSITION /INFORMATION. ON . INGREDIENTS CAS # % (BY WT) OSHA 8052 -42-4 50 — 70 NE 8052 -41 -3 30 — 50 500 ppm RECEIVED CITY OF TUKWILA Page 1 of 7 JUN' 1 8 2UUy PERMIT CENTER GAF Materials Corporation Material Safety Data Sheet MSDS # 1086 MSDS Date: December 2008 Reactive Personal Protection ACGIH 0.5 mg /m3 (inhalable fraction, as benzene - soluble aerosol) 100 ppm FILE COPY Permit No. Pi ?r review apOrovvl is subject to errors ;Ind omis . .REVIEWED FOR , CODE COMPLIANCE APPROVED JUN 2 5 2009 City of Tukwila BUILDING DIVISION HMIS Hazard Rating 2 2 0 X No ❑ OCCUPATIONAL EXPOSURE LIMITS OTHER 5 mg /m3 — Ceiling (15 min. fumes) 350 mg /m3 b01- 103 GAF Materials Corporation MSDS # 1086 NE = Not Established SECTION 3: HAZARDS IDENTIFICATION PRIMARY ROUTE OF EXPOSURE: Inhalation, Skin Absorption, Ingestion SIGNS & SYMPTOMS OF EXPOSURE EYES: Irritation and watering of the eyes. Prolonged or repeated contact can cause blurred vision and corneal injury. SKIN: Irritation of skin, redness and possible swelling. Prolonged or repeated contact can cause dermatitis, defatting. Can be absorbed through skin. INGESTION: Choking difficulty in breathing, gastrointestinal irritation, nausea and vomiting. Nervous system depression, which can include drowsiness, dizziness, loss of coordination and fatigue. INHALATION: Breathing difficulty, lightheadedness, headache, dizziness and nausea. Irritation to the nose, throat and lungs. Prolonged inhalation may lead to mucous membrane irritation, central nervous system depression, and unconsciousness. ACUTE HEALTH HAZARDS: CHRONIC HEALTH HAZARDS: CARCINOGENICITY: SECTION 4: FIRST AID MEASURES Breathing difficulty, headache, dizziness, nausea and irritation to the respiratory tract. Causes eye and skin irritation. Irritation of the digestive tract and nervous system depression. Ingredients in this product are reported to aggravate preexisting eye, skin, respiratory, kidney and liver disorders. Prolonged and repeated overexposure may cause permanent brain and or nervous system damage. Can cause dermatitis. Sanding dust inhalation may cause lung damage. Intentional misuse through inhalation may be harmful or fatal. The International Agency for Research on Cancer (IARC) has determined that there is limited or inadequate evidence in humans for the carcinogenicity of exposure to asphalt. Classified as a Group 2B (Possibly Carcinogenic to Humans). There is a trace amount of crystalline silica in this product. The International Agency for Research on Cancer (IARC) and the National Toxicology Program (NTP) have determined that there is sufficient evidence in humans for the carcinogenicity of inhaled crystalline silica in the form of quartz or cristobalite. In addition, IARC has determined that there is sufficient evidence for the carcinogenicity of quartz and cristobalite in experimental animals. Among individuals with silicosis, lung cancer occurs more frequently in those who smoke. Page 2 of 7 GAF Materials Corporation MSDS # 1086 FIRST AID PROCEDURES EYES: SKIN: INHALATION: INGESTION: NOTES TO PHYSICIANS OR FIRST AID PROVIDERS: SECTION 6: FIRE FIGHTING PROCEDURES HAZARDOUS COMBUSTION PRODUCTS: RECOMMENDED FIRE FIGHTING PROCEDURES: UNUSUAL FIRE & EXPLOSION HAZARDS: SECTION 6: ACCIDENTAL RELEASE; MEASURES ACCIDENTAL RELEASE MEASURES: Flush with large quantities of water for at least 15 minutes. Seek immediate medical attention. Wash thoroughly with soap and water. If irritation persists, get medical attention. Remove to fresh air. Administer oxygen if necessary. Seek immediate medical attention. Do not induce vomiting. Drink 1 or 2 glasses of water to dilute. Obtain medical attention immediately. Repeated/continuous exposure can cause chemical pneumonia, liver /kidney damage. Large amounts may need immediate emergency treatment. Repeated /continuous exposure can aggrevate emphysema. SUITABLE EXTINGUISHING MEDIA: Dry chemical, foam, water fog or CO2. Nitrogen oxides and carbon oxides. Wear a self - contained breathing apparatus with a full face piece operated in the positive pressure demand mode with appropriate turn -out gear and chemical resistant PPE. Water may be ineffective in extinguishing fire. Use self - contained breathing apparatus. Do not use water stream on burning liquid. If water is used to cool containers near fire, fog nozzles are preferred. Closed containers may explode when exposed to extreme heat or fire. Material may splatter if exposed to extreme heat. Decomposition of burning material may cause toxic gases to form, which may include carbon dioxide and carbon monoxide. Avoid contact and breathing of vapors. Ventilate area. Remove ignition sources. Dike and absorb with absorbent material. Use nonsparking tools to return material to container. Prevent material from entering sewers or open bodies of water. Page 3 of 7 APPEARANCE & ODOR: Dark colored liquid with solvent odor. FLASH POINT: 106 °F LOWER EXPLOSIVE LIMIT: 0.7% METHOD USED: TCC UPPER EXPLOSIVE LIMIT: 6.0% EVAPORATION RATE: Slower than ether BOILING POINT: 315 °F GAF Materials Corporation MSDS # 1086 SECTION 7: HANDLING AND STORAGE HANDLING AND STORAGE: OTHER PRECAUTIONS: SECTION 8: EXPOSURE .CONTROLS/PERSONAL, ENGINEERING CONTROLS / VENTILATION: RESPIRATORY PROTECTION: EYE PROTECTION: SKIN PROTECTION: OTHER PROTECTIVE EQUIPMENT: WORK HYGIENIC PRACTICES: EXPOSURE GUIDELINES: N/A N/A None. SECTION 9: PHYSICAL AND CHEMICAL PROP.ERtiES Keep out of reach of children. Do not take internally. Avoid contact with eyes and prolonged contact with skin. When storing, close tightly, keep upright, away from fire and high temperatures. Transfer to approved containers with complete and appropriate labeling. Avoid freefall and ground containers when transferring. Do not cut or weld empty drum. Remove contaminated clothing and launder before reuse. Remove contaminated shoes and thoroughly dry before reuse. Wash skin thoroughly with soap and water after contact. Local exhaust preferable. If venting, discharge exhaust away from ignition sources. If in confined areas, use mechanical ventilation to keep vapor concentration under permissible TLV and LEL. Use only with adequate ventilation. Provide adequate fresh air entry. If not wear the proper respiratory protection. If ventilation is inadequate use an organic vapor /particulate respirator approved by NIOSH /MSHA for spray /mist vapors. When sanding a dried coating film use a dust/mist respirator approved by NIOSH /MSHA for dust which may be generated. Splash resistant and spray mist protection required. Use splash goggles or safety glasses with side shields. Solvent impermeable rubber gloves required during repeated contact. Wear gloves and safety goggles to prevent irritations. Wash hands with soap and water or waterless cleaner. Page 4 of 7 GAF Materials Corporation SECTION 10: STABILITY AND REACTIVITY THERMAL STABILITY: CONDITIONS TO AVOID (STABILITY): Elevated temperatures and build up of vapors. Heat, sparks and open flame. Avoid free fall. INCOMPATIBILITY (MATERIAL TO Oxidizers, acids and bases. AVOID): HAZARDOUS DECOMPOSITION OR BY- Burning or decomposing film may give off carbon dioxide and PRODUCTS: or carbon monoxide. HAZARDOUS POLYMERIZATION: Will not occur. SECTION 11: TOXICOLOGICAL INFORMATION TOXICOLOGICAL No information available. INFORMATION: SECTION 12: ECOLOGICAL INFORMATION ECOLOGICAL INFORMATION: No information available. SECTION 13: DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHOD: MSDS # 1086 This product, as supplied, is regulated as a hazardous waste by the U.S. Environmental Protection Agency (EPA) under Resource Conservation and Recovery Act (RCRA) regulations. If discarded in its purchased form, this product is a RCRA hazardous waste. It is the responsibility of the product user to determine at the time of disposal, whether a material Page 5 of 7 STABLE X UNSTABLE ❑ pH (undiluted product): No data MELTING POINT: No data SOLUBILITY IN WATER: Insoluble SPECIFIC GRAVITY: 0.9 VAPOR DENSITY: Heavier than air PERCENT VOLATILE: < 40% VAPOR PRESSURE: No data MOLECULAR WEIGHT: No data VOC WITH WATER (LBS /GAL): 2.68 WITHOUT WATER (LBS /GAL): 2.68 GAF Materials Corporation SECTION 10: STABILITY AND REACTIVITY THERMAL STABILITY: CONDITIONS TO AVOID (STABILITY): Elevated temperatures and build up of vapors. Heat, sparks and open flame. Avoid free fall. INCOMPATIBILITY (MATERIAL TO Oxidizers, acids and bases. AVOID): HAZARDOUS DECOMPOSITION OR BY- Burning or decomposing film may give off carbon dioxide and PRODUCTS: or carbon monoxide. HAZARDOUS POLYMERIZATION: Will not occur. SECTION 11: TOXICOLOGICAL INFORMATION TOXICOLOGICAL No information available. INFORMATION: SECTION 12: ECOLOGICAL INFORMATION ECOLOGICAL INFORMATION: No information available. SECTION 13: DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHOD: MSDS # 1086 This product, as supplied, is regulated as a hazardous waste by the U.S. Environmental Protection Agency (EPA) under Resource Conservation and Recovery Act (RCRA) regulations. If discarded in its purchased form, this product is a RCRA hazardous waste. It is the responsibility of the product user to determine at the time of disposal, whether a material Page 5 of 7 STABLE X UNSTABLE ❑ Chemical Name CAS # CA MA MN NJ PA RI Asphalt 8052 -42 -4 Yes Yes Yes Yes Yes Yes GAF Materials Corporation MSDS # 1086 RCRA HAZARD CLASS: D001, Ignitable Hazardous Waste SECTION 14: TRANSPORTATION INFORMATION U.S. DOT TRANSPORTATION SECTION. 15: REGULATORY INFORMATION U.S. FEDERAL REGULATIONS containing the product or residue of the product remains classified a hazardous waste as per 40 CFR 261, Subpart C. State or local regulations may also apply if they differ from the federal regulation. PROPER SHIPPING NAME: Flammable Liquid N.O.S. HAZARD CLASS: 3 ID NUMBER: UN 1993 PACKING GROUP: III LABEL STATEMENT: Class 3 Flammable Liquid Label OTHER: N/A TSCA: This product and its components are listed on the TSCA 8(b) inventory. CERCLA: None SARA 311/312 HAZARD CATEGORIES: Acute Health Hazard, Chronic Health Hazard, Fire Hazard 313 REPORTABLE INGREDIENTS: None CALIFORNIA PROPOSITION 65: This product contains a chemical known to the state of California to cause cancer and birth defects, or other reproductive harm. Cancer: crystalline silica (trace). Other state regulations may apply. Check individual state requirements. The following components appear on one or more of the following state hazardous substances lists: Page 6 of 7 GAF Materials Corporation Stoddard Solvent 8052 -41 -3 Yes Yes Yes Yes Yes Yes SECTION 16: OTHER INFORMATION ADDITIONAL COMMENTS: None DATE OF PREVIOUS MSDS: February 2004 CHANGES SINCE PREVIOUS MSDS: Changed to the ANSI 16 section MSDS format. Page 7 of 7 MSDS # 1086 This information relates to the specific material designated and may not be valid for such material used on combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. MB 7 /BUR 7 ALTERNATE HIGH PARAPET WALL DETAIL NOTES: ENERGYGUARDTM CANT STRIP - SET IN BITUMEN Rashing Details 335 FASTENERS MAXIMUM 8" O.C. FOR HEIGHTS UP TO 12" AND 4" D.C. FOR HEIGHTS ABOVE 12" RUBEROID®/ GAFGLAS® BASE FLASHING 8° MIN. BASE/PLY SHEETS RUBEROID®/GAFGLAS® MEMBRANE ENERGYGUARDTM INSULATION DECK 1. MASONRY WALLS TO BE PRIMED PRIOR TO FLASHING. WOOD WALLS REQUIRE BASE SHEET NAILED TO WALL 9" O.C. ALONG TOP P ND LAPS, ONE FASTENER EVERY SQUARE FOOT IN THE FIELD. 2. WALL COVERINGS TURNED OVER EDGE A MINIMUM OF 1 1/2" (38mm) OR THICKNESS OF NAILER WHICHEVER IS GREATER. 3. REFER TO DETAIL MB / BUR 7 FOR ALTERNATE WALL FLASHING METHOD 4. FASTEN BASE FLASHING APPROXIMATELY 8° O.C. FOR HEIGHTS UP TO 12" AND 4° O.C. FOR HEIGHTS UP TO 24" 5. FOR WALL FLASHINGS IN EXCESS OF 4' CONTACT GAF TECHNICAL SERVICES AT 1- 800 -ROOF -411 WALL COVERING OPTIONS: RUBEROID® OR GAFGLAS® MEMBRANE EVERGUARD® TPO OR PVC LEXSUCO® FLASHINGS TOPCOAT ® WALLCOTE FASTENERS APPROX.12" O.C. m id CORPORATION MB 15/BUR 15 - VENT STACK FLASHING DETAIL PREFERRED ALTERNATE NOTE: Flashing Details 343 ROLL LEAD FLASHING 1' DOWN INTO PIPE PLUMBING VENT STACK RUBEROID / GAFGLAS BASE FLASHING RUBEROID®/ GAFGLAS® MEMBRANE BASE / PLIES ENERGYGUARDTM' INSULATION PRIMED LEAD FLASHING, MINIMUM 21/2 TO 4 LBS. SET PRIMED FLANGE IN ROOF CEMENT ON MOP, COLD MB AND BUR. SET PRIMED FLANGE IN HEAT SOFTENED MEMBRANE ON TORCH APP AND HW SBS DECK 1. SHEET LEAD MINIMUM OF 2 -1.'2 POUNDS PER SQUARE FOOT. 2.MINIMUM 18' CLEARANCE FROM PIPES, WALLS AND CURBS. 3. FOR TORCH APPLIED RUBEROID, TORCH THE AREA OF RUBEROID MB MEMBRANE OVER WHICH THE METAL IS TO BE Pi ACED AND SET THE METAL INTO THE MB WHILE THE MB IS STILL MOLTEN. ppr GAF RUCIERIALS CORPORATION Description MATRIX TM 203 Plastic Roof Cement is a general purpose, asbestos free formulation for use as a cold-applied sealant and repair material in all types of roof systems. This product is scientifically compounded with premium materials to enhance resistance to flow and increase durability. Heavy, "trowel - grade° consistency makes this product ideal for flashing details and a variety of roofing and waterproofing , such as moving joints and roof penetrations. A bonding strength and high flexibility to accommodate temperature-related j on include superior peraturrLr+elated expar>slonand contraction of the roof system. o Heavy, "trowel - grade° consistency makes this product ideal for flashing details, and a variety of roofing waterproofing repairs, such as moving joints and roof penetrations. o Superior bonding strength and high flexibility to accommodate temperature-related expansion and contraction of the roof system. • Easy Application ...smooth, trowel -grade cement — maintains excellent low temperature flexibility. ▪ Recommended for use by major membrane manufacturers — including GAF Materials Corporation and U.S. Intec. ° Uses MATRIX TM 203 Plastic Roof Cement heavy, "trOYVet- grad@' consistency is ideal for Sealing leaks and openings around fleshings, chimneys, vents, skylights, joints in metal edging, gutters objects • • Sealing shingles, repairing asphalt built-up, metal, and masonry roofs • Constructing built-up fleshings Filling flashing pans around roof penetrations • Damp proofing the exterior side of concrete and masonry walls and asphalt roof cement Approvals & Certification MATRIX 203 Plastic Roof Cement is listed and approved by the following agencies or code bodies: Underwriters Laboratories (UL). Meets or exceeds the requirements of ASTM D-4586 Asphalt Roof Cement Asbestos -free, Type I. Surface Preparation Application • FILE COPY MATRIXTm 203 Plastic Roof Cement Long - Lasting Sealant/Trowel Grade Consistency � FTU CENE�D � O JUN :18 2009 PERMIT CENTER All surfaces must be dean, dry and free from any foreign matter, such as oil, grease, dirt or debris that could inhibit the bonding capabilities of the cement. On existing roofs, inspect removal of existing roof. Check local building codes; local building codes condition; moisture in old roof may require complete g out and y require complete buckles les and of raised edges s of. Contact GAF or U.S. lntec Contractor Services for details on cutting a smooth surface. Check all fleshings, � repahing blisters, buckles and raised edges for 9s, edges, drains, valleys and vents and repair as needed. REVIEWED FOR • MPLIANCI 'PROVED JUN 2 5 2009 City of Tukwila DIVISION Application Rate: Typical e a�ication is 8 gallons per square for a %" coat Application Method: Use p� ot substrate and Method: notched trowel or aged putty knife to apply cement evenly and in equal amounts to rrpembrane flashing. Coat should be W thick on each surface, without gaps, dry areas or bubbles. smoothing Attachment: Membrane Rashing: No cure time before attaching flashing amply p into place with even pressure, wry out bubbles. Adhere membrane to cemented substrate and press into place working out any visible at r non-adhered op edges. areas, n making sure a sufficient amount of cement is applied to the laps so that a bead of cement is Appl cement to and in I fasten membrane flashing on parapet wails to avoid membrane slippage. Cou sing: finished y glass polyester fabric into cement, repeat method for desired courses. When ' coat with another layer of cement Metal: All metal should be primed. Set metal flanges in full bead of W thick cement. Apply cement between joints and Sealin apply pressure so that a bead of cement is visible at joint edge. g/Repafr Apply cement at a %" to W thickness, working the cement into the opening or crack and spread beyond repair area approximately 2" - 4°. If repair area is over'/." wide or more than 2" long, embed glass or polyester fabric into the cement for added reinforcement, then cover with additional cement extended 2° - 4" beyond the fabric repair. If desired, repeat procedure for coursing application and feather each layer of fabric beyond underlying layer. o°I 103 Leak® Buster Repair& Maintenance Products MATRIXTm 203 Plastic Roof Cement Long-Lasting Sealant/Trowel Grade Consistency Description MATRIX Tm 203 Plastic Roof Cement is a general purpose, asbestos free formulation for use as a cold-applied sealant and repair material in all types of roof systems. This product is scientifically compounded with premium materials to enhance resistance to flow and increase durability. Heavy, » trowel-grade" consistency makes this product ideal for flashing details and a variety of roofing and waterproofing repabs, such as moving joints and roof penetrations. Advantages include superior bonding strength and high flexibility to accommodate temperature-related expansion and contraction of the roof system. • Heavy, "trowel-grade" consistency makes this product ideal for flashing details, and a variety of roofing waterproofing repairs, such as moving joints and roof penetrations. • Superior bonding strength and high flexibility to accommodate temperature-related expansion and contraction of the roof system. • • Fasy Application ...smooth, trowel-grade cement — maintains excellent low temperature flexibility. Recommended for use by major membrane manufacturers — including GAF Materials Corporation and U.S. intec. Uses MATRIX TM 203 Plastic Roof Cement heavy, "trowel-grade" consistency is ideal for o Sealing leaks and openings around fleshings, chimneys, vents, skylights, joints in metal edging, gutters and similar objects • Sealing shingles, repairing asphalt built-up, metal, and masonry roofs Constructing built-up fleshings • Filling flashing pans around roof penetrations • Damp proofing the exterior side of concrete and masonry walls and asphalt roof cement Approvals & Certification filATRIX 203 Plastic Roof Cement is listed and approved by the following agencies or code bodies: Underwriters Laboratories (UL). Meets or exceeds the requirements of ASTM D-4586 Asphalt Roof Cement Asbestos-free, Type I. Surface Preparation US MIAMI-DADE All surfaces must be dean, dry and free from any foreign matter, such as oil, grease, dirt or debris that could inhibit the bonding capabilities of the cement. On existing roofs, inspect roof deck condition; moisture in old roof may require complete removal of existing roof. Check local building codes; local building codes may require complete removal of existing roof. Contact GAF or U.S. Intec Contractor Services for details on cutting out and repairing blisters, buckles and raised edges for a smooth surface. Check all fleshings, edges, drains, valleys and vents and repair as needed. Application Application Rate: Typical application rate is 8 gallons per square for a %" coat. Application Method: Use notched trowel or wide-edged putty knife to apply cement evenly and in equal amounts to substrate and SBS membrane flashing. Coat should be W thick on each surface, without gaps, dry areas or bubbles. Attachm ent Membrane Flashing: No cure time before attaching flashing; simply press into place with even pressure, smoothing out wrinkles and bubbles. Adhere membrane to cemented substrate and press into place working out any wrinkles or non-adhered areas, making sure a sufficient amount of cement is applied to the laps so that a bead of cement is visible at all lap edges. Mechanically fasten membrane flashing on parapet walls to avoid membrane slippage. Coming: Apply cement to surface and install glass or polyester fabric into cement, repeat method for desired courses. When finished, coat with another layer of cement Metal: All metal should be primed. Set metal flanges in full bead of W thick cement Apply cement between joints and apply pressure so that a bead of cement is visible at joint edge. Seating/Repairs: Apply cement at a W to W thickness, working the cement into the opening or crack and spread beyond repair area approdmately - 4". If repair area is over 1/4» wide or more than 2" long, embed glass or polyester fabric into the cement for added reinforcement, then cover with additional cement extended 2° - 4" beyond the fabric repair. If desired, repeat Procedure for coursing application and feather each layer of fabric beyond underlying layer. Precautions Compatibility & Limitations: Do not use with any APP modified products. Do not use on wet or damp surfaces, directly over wood or on surfaces previously covered with coal tar products. Do not use with SBS modified bitumen membranes. Temperature Range: Apply only when temperatures are 45 °F (7.2° C) and rising. Cold weather will cause product to stiffen, making application difficult Store 24 hours at room temperature prior to application. Do not heat container or attempt to thin this product. Not recommended for application on substrates that exceed 140 °F (60° C). Storage/Handling & FIRE WARNING: MATRIXmi 203 Plastic Roof Cement is COMBUSTIBLE and should always be kept away from heat, open flame and any source of ignition. Observe normal safeguards for storing and handling of this product prior to and during application. Do not allow the roof cement to freeze. Important Repair leaks promptly to avoid adverse effects, including, but not limited to, mold growth. Clean Up Keep containers covered when not in use. Clean equipment and over spray with kerosene, mineral spirits or petroleum naphtha. Clean hands with waterless hand cleaner. Caution MATRIX TM 203 Plastic Roof Cement contains petroleum distillate. Ventilation - use with adequate ventilation and dose containers when not in use. If TLV (Total Level of Vapor) is exceeded, respirators are required (NIOSH/MSHA). Inhalation of high vapor concentration may result in headaches and/or dizziness. Remove individual to fresh air and administer oxygen if breathing is difficult. If breathing has stopped, administer artificial respiration, keep victim warm and order emergency medical attention immediately. Eye Contact - Rinse immediatety with water for 15 es and seek medical advice. Personal Protection - Irritation may result from prolonged or repeated contact with skin. minut Wear chemical resistant gloves, protective goggles and protective clothing, if needed. Fire Protection - MATRIXTM' Plastic Roof Cement 203 is COMBUSTIBLE and should always be kept away from heat, open flame and any source of ignition. Waste Disposal - Empty containers must be disposed of in an approved landfill in accordance with local, state and federal regulations. DATA REPORTED ARE BASED ON AVAILABLE INDEPENDENT AND IN -HOUSE RESOURCES. BUILDING MATERIALS CORPORATION OF AMERICA RESERVES THE RIGHT TO CHANGE OR MODIFY, AT ITS DISCRETION AND WITHOUT PRIOR NOTICE, ANY OF THE INFORMATION, REQUIREMENTS, SPECIFICATIONS OR POLICIES CONTAINED IN THIS DOCUMENT. Limited Warranty BMCA Building Materials Corporation of America (BMCA) warrants that at the lime of delivery, the product contained herein shall conform to ati therefore THIS WARRANTY IS EXCLUSIVE AND IS IN UEU OF AU- OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPUED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE It is Purchaser's sole responsibility to determine the suitability of this product for any particular application. Recommendations made by BMCA are believed to be reliable, but BMCA makes NO WARRANTY OF RESULTS to be obtained. Purchaser's sole and exclusive remedy, regardless of the theory on which a claim may be based (inducting, without limitation, negligence, contrac breach of warranty, strict product liability or misrepresentation) is the replacement of this product, or, In the alternative, the original purchase price of this product. In NO event shall BMCA be liable for INCIDENTAL, CONSEQUENTIAL, SPECIAL, INDIRECT OR PUNITIVE DAMA(FS. Purchaser must of discovery writing, of any daim at 1361 Alps Road, Bldg. 11, Wayne, NJ 07470; Attention: Contractor Services Dept. within 30 days ofocsure, o at BM manufacturing in option, defect Purchaser must allow BMCA to inspect this product as installed as part of the daims else is authorized to modify, the terms of this limited warranty a taken from the roof. agent or employee of BMCA or anyone Physical Properties Weight: VOC (max): Non- volatile content: SETA Flash Point Sizes: 5 gal/18.9 liters For Application Questions GAFMC Contractor Services at 1.800- 766 -3411 or visit www.gafoorg U.S. Intec Contractor Services at 1 - 800 - 624-6832 or visit www.usintec.com Recommended By Major Manufacturers, Including: 9.0 lb. (4.1 kg) per gallon 210 grams/liter 70 % minimum 110° F • Manufactured By: Building Materials Corporation Of America 1361 Alps Road, Wayne, NJ 07470 02004 Building Materials Corporation Of America 06/04 USICC107 Precautions Compatibility & Limitations: Do not use with any APP modified products. Do not use on wet or damp surfaces, directly over wood or on surfaces previously covered with coal tar products. Do not use with SBS modified bitumen membranes. Temperature Range: Apply only when temperatures are 45 °F (7.2° C) and rising. Cold weather will cause product to stiffen, making application difficult. Store 24 hours at room temperature prior to application. Do not heat container or attempt to thin this product. Not recommended for application on substrates that exceed 140 °F (60° C). Storage/Handling 8 FIRE WARNING: MATRIXTM 203 Plastic Roof Cement is COMBUSTIBLE and should always be kept away from heat, open flame and any source of ignition. Observe normal safeguards for storing and handling of this product prior to and during application. Do not allow the roof cement to freeze. Important: Repair leaks promptly to avoid adverse effects, inducting, but not limited to, mold growth. Clean Up Keep containers covered when not in use. Clean equipment and over spray with kerosene, mineral spirits or petroleum naphtha. Clean hands with waterless hand cleaner. Caution MATRIX TM 203 Plastic Roof Cement contains petroleum distillate. Ventilation - use with adequate ventilation and dose containers when not in use. If TLV (Total Level of Vapor) is exceeded, respirators are required (NIOSH/MSHA). Inhalation of high vapor concentration may result in headaches and/or dizziness. Remove individual to fresh air and administer oxygen if breathing is difficult. If breathing has stopped, administer artificial respiration, emergency medical attention m immediately. � keep victim warm and order advice. Persona l Protection ona ediately Eye Contact - Rinse with water for 15 minutes and seek medical advice. Personal ion may result from prolonged or repeated contact with skin. Wear chemical resistant COMBUSTIBLE goggles and protective dothing, if needed. fire pin - MATRIXT" Plastic Roof Cement 203 is CO containers must should disposed always be kept away from heat, open flame and any source of ignition. Waste Disposal - of in an approved landfill in accordance with local, state and federal regulations. DATA REPORTED ARE BASED ON AVAILABLE INDEPENDENT AND IN -HOUSE RESOURCES. BUILDING MATERIALS CORPORATION OF AMERICA RESERVES THE RIGHT TO CHANGE OR MODIFY, AT ITS DISCRETION AND WITHOUT PRIOR NOTICE, ANY OF THE INFORMATION, REQUIREMENTS, SPECIFICATIONS OR POLICIES CONTAINED IN THIS DOCUMENT. Limited Warranty Building Materials Corporation of America (BMCA) warrants that at the time of delivery, the product contained herein shall conform to BMCA's specifications therefore THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE It is Purchaser's sole responsibility to determine the suitability of this product for any particular application. Recommendations made by BMCA are believed to be reliable, but BMCA makes NO WARRANTY OF RESULTS to be obtained. Purchasers sole and exclusive remedy. regardless liability o oe theory on which a claim may be based (including, without limitation, negligence, contract, breach of warranty, strict Product misrepresentation) is the replacement of this rod u NO event shall BMCA be liable for INCIDENTAL, CONSEQUENTIAL, SPECIAL. INDIRECT OR original NITIVE DAMAGES. Purchaser must notify BMCA, in writing, of any claim at 1361 Alps Road, Bldg. 11, Wayne, NJ 07470; Attention: Contractor Services Dept within 30 days of discovery of any alleged manufacturing defect Purchaser must allow BMCA to of Procedure, or at BMCA 's option, must provide BMCA with ads taken from roof. r000 this Product as installed No agent or employee o o part f BMCA A the or any ny i n e else is authorized to modify the terms of this limited warranty. one Physical Properties Weight: 9.0 lb. (4.1 kg) per gallon VOC (max): Non volatile content 7 0 0 grams/liter mum 70 % minimum SETA Flash Point 110° F Sizes: 5 ga1/18.9 liters For Application Questions GAFMC Contractor Services at 1 800 - 766 -3411 or visit www. U.S. Intec Contractor Services at 1- 800-624 -6832 or visit www.usintec.eom Recommended By Major Manufacturers, Including: Manufactured By: Building Materials Corporation Of America 1361 Alps Road, Wayne, NJ 07470 02004 Building Materials Corporation Of America 06/04 USICC107 Li t Qtr t ' i ) 40 rr Perlite Tapered Edge Strip Description • Factory fabricated from EnergyGuard" rigid perlite insulation board. • Cut on angles that slope from zoro on one edge to 1/2" to 2" on the opposite edge. • Designed for smooth transition from lower to higher elevatiorm • Easy to fabricate fo. in;;ta:iation with most types of roof systems. • Available in bundles 48" (1220 mm) in length. • Available in different heights and widths for all types of job requirements as follows: Edge Strip Sizes` ' /7" (13 mm) x h" (152 mm) x 48" (1220 mm's /t" (13 mm) x 12" (305 mm) x4 (1220 mm) 1" _ (25 mm) _ >; 6" (152 mrn) 48" (1220 mm) mj m x 12' "5305 mm) x48" (1220 mm) _ (25 mm) x 18 "(4 ,7r x 48" (1220 mm) 1 " 7 ? <' ,f.1 mr. . 48 „1220 mm) 17 /2” (38 mm! x o" (I'.;' rtn i x n8' (1220 mm) 1'/,_( mm) x 12" (3G5 rnm; x -)8" (1'220 mm)' _1'/7" (38 rnmj x 1F," (1 i7 mm) x 48 " t1220 mm) 1' /z_( (38 mm) x 24" (610 mm) x 48" (1220 mm) mm) x 72" ( 3( ? m x 48" (1220 mmj 2 "�51 mmj x id" 2" (51 mm) (457 mm x 48" 1220 mm m) �_ . - ) x 24" (61 mm) x 48" (1220 mn1) 'Ali sizes shown are nominal and subject to normal manufacturing tolerances Uses • To provide smooth transition from lower to higher elevations around roof edges, drains or wherever slope to 0" is required. • Properly installed. EnergyGuard'" Perlite roof insulation is suitable for use under built -up, modified bitumen and some single ply roofing systems. • Refer to the application specifications in the current Membrane Manufacturer's Application and Specifications manual for proper installation procedures for EnergyGuard" Perlite roof insulation. Specification Benefit ° UL, ULC Flame Spread Rating 25 • Strong and dimensionally , labl•; • Available in standard heights and widths. • Can be shipped in mix/xi ;oath., hLh root insulation and tapered systems. • Multiple shipping locations. • Easily identifiable bundles. • Edge strips have at least 25% post - consumer recycled content and comply with the Environmental Protection rM EnergyG uard Insulation Products EnergyGuard'" Perlite Tapered Edge Strip WOOD NAILER REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 5 2009 BUILDING itY of Tukwila DIVIS1ON Agency Regulation 40 CFR Part 248, "Guideline for Federal Procurement of Building Insulation Products Containing Recovered Materials," as a recycled product approved for use on any project using federal funds. Limitations • EnergyGuard" Perlite roof insulation is a non - structural, non -load bearing material. • EnergyGuard'" Perlite roof insulation should be stored dry and be protected from the elements. Once properly loaded at the job site, remove factory wraps and cover with a breathable tarp. • No more insulation should be applied than can be completely covered with finished roofing on the same day. • I' is NOT designed for use under fully adhered single ply systems nor for direct torch application of modified bitumen. • If torch grade modified bitumen roofing is to be installed over EnergyGuard'" Perlite, a fiberglass base sheet MUST first be installed. E EIVE CITY R OFTU LA JUNI' 8 2009 PERMIT CENTER DO1 I OS r+01 °' trrr Per lite C (nt Stag Formerly BMCA Permajte® Cant Strip Description • Factory fabricated from rigid EnergyGuard "Perlite insulation board. • Cut at angles that provide a !rue 45° angle between t onzonlaO and vertical surfaces. UI_, ULC Flamc ; t tct Rat)nc, 2 ; • Easy t,) f; bricara )• :3.11'11011 with most types of re .1 sterns • Strips are available n: 3" 4", 5' and 5 3/4" (76, 1C2. 127 an.± 146rr. nominal sizes. Cant Sizes' 1" (25 mm) a 4" (162 mm) x 48" mm) (1220 mm) 1" _ (25 mm) x 3" (76 rnm) x 48" 1 220 mm) 1"2" (38 mm) x 4' (1_2 :TIM) x 48" r 1220 min) (38 mm) x 5" (127 mm x 4 .8 • (1220 mm) 1'/:" (38 mm) ) 5 (r46 mm` x 48" (1220 rnm) 'All sizes shown are nom,-.)r and subject t.) nominal manufacturing tc...)ran :es Uses ° To provide a smooth irdrisittr)n from horizontal to vertical surfaces. • Properly installed. EnergyGuard" Perlite Cant Strip is suitable for use under built -up. modified bitumen and some single ply rooting w: :' '1rr..s. ° Refer to the application specifications in the current membrane' manufacturer's application and specifications manual for proper installati;,.1 pros ensures for EnergyGuard' Perlite Cant Strip. Benefits • Strong and dimensionally stable. • Available in 5 standard sizes. • Can he shipped in mixed toads with roof Insulation and tapered systems. • Multiple shipping locations. • Easily identifiable bundles "'bite TM s )311P OF ItMERMA i i s TM EnergyGuard'" Perlite Cant Strip Cant Strip EnergyGuardTM Insulation Products ' INSULATION COURSE ' Limitations • EnergyGuard'" Perlite Cant Strips are a non - structural, non -load bearing material. ° EnergyGuard"' Perlite Cant Strips should be stored dry and be protected from the elements. Once properly loaded at the job site, remove factory wraps and cover with a breathable tarp. • No more Cant Strip should be applied than can be completely covered with finished roofing on the same day. Do NOT use under fully adhered single ply systems or with direct torch application of modified bitumen. • If torch grade modified bitumen roofing is to be installed over EnergyGuard'" Perlite Cant Strips, a fiberglass base sheet MUST first be installed. Code Compliance o EnergyGuard"" Perlite Cant Strip complies with the requirements of ASTM Standard C728 (which supercedes Federal Specifications HH -I -529). ° UL Flame Spread Rating 25. ° Cant Strips have at least 25% post- consumer recycled content and comply with the Environmental Protection Agency Regulation 40 CFR Part 248, "Guideline for Federal Procurement of Building Insulation Products Containing Recovered Materials," as a recycled product approved for use on any project using federal funds. < Fields Hrn T1, T2 Type 1 USES: Fic-' protectiv applied tc. SEBS, APP, DESCRIP : '. against th tempera? (uftravich. • easily bre . defense a•. :. installatio.� Laborator ira SPECIFICA"1 " ': ` I 1 Testing al c. PACKAG4 P': • . MeltBulk :. . POUNDS Base Sheet oated BUR i B Uncoated 3! SEBS, APF, 1 Sheet At Coated Uncoated E SEBS, APP, & S• . •-• Protective Coated BUR "• Uncoated o SEBS, APP Miscellanea; Ca Sheet ' Ri.id Insulaa , •. .25" Pea Grd BUR ". t '. a • -. ill o , ::Ialut,l 111L C/1 A11aLHJ11 E A PILE COPY R a• r. MeftP. c:, &Meg, & MeltBui It p e " 1 " Hot Applied Asphalt d Asphalts protect surfaces exposed to the weather: They are excellent - ,r roofs, foundations, concrete, and metal. In addition, Fields Hot Asphalts are I and waterproofing sheets. Fields Hot Applied Asphalts are compatible with •:•'bber modified asphalts and will adhere to most surfaces. DIRECTica'• r:' �. ,applying Fields Hot Asphalt as a protective coating, clean away all loose gravel, di - > . and debris from the application area. The application surface shall be firm, clean, dr « , . , .nd smooth. Seal any leaking penetrations and repair membrane damage with M30 Uniformly apply a coating of Fields Hot Asphalt at the rate of 30 pounds per 100 squur :: any of the following Fields roofing and waterproofing sheets with Fields Hot Applied • ibrPoly, M64 R!, brPoly2, F50 PolyShield, F55 PolyShield2, M62 RubrGlas, M66 RubrG , , .;iasBase2, F56 GlasPly6, or F54 GlasPly4. Uniformly apply 30 pounds per 100 square feet . IL Asphalt for base and ply sheet adhesives. For maximum protection and reduced e -,.: • . apply M800 RubrStar over Fields Hot Applied Asphalts. Allow Fields Hot Applied A' ;, ` ; • ,«num of 90 days to set up before applying the RubrStar. .• Hot Applied Asphalt is an asphalt that provides superior elastic performance the daily expansion and contraction of a roof membrane caused by oof membranes are also penetrated by the sun's destructive UV s destroy a roofS elasticity. Roofs made brittle and weak from W rays assault o' thermal shock cycles. Fields Hot Applied Asphalt is your best stacks. VY lth: Fields Hot Applied Asphalt, your roofing and waterproofing i much longer. Fields Hot Applied Asphalts have a UL (Underwriters • ire Rating _ids Hot Applied Asphalts exceed the standards of the American Society for - ''.) • vieltPacs are available in 50 pound bricks, Ti, T2, T3, & T4 MeltKeg and . 100 pound kegs and bulk. :10T ASPHALT TO APPLY PER 100 SQUARE FEET: ra- REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 5 1009 City of Tukwila BUILDING DIVISION rage i of L RECEIVED CITY ofd ruKlM A JUN t . 8 2009 PERMIT CENTER PO'H03 h.ttp : / /ty - ww. i iClc „ rp.c, ir.'.: :otrunercial /products /prodlnfo/hotpi.html 4/30/2009 .V..iu. , ■ l,c r . _ . ik i r10t spnaiis Yroauct information Page 2 of 2 MELTAB 1 LIED ASPHALT MeltPacs: T3 & T + • ,i ; ied Asph mlts are packaged in meltable plastic brick packages. Each MeltPac weighs • • • :ing it pc, ;sible to place the entire MeltPac into an asphalt kettle and complet�_i' ck incl::i"ing the plastic wrapper and the asphalt. In addition, Fields Hot Applied -, . . •:;tes all disposal costs, reducing the volume of waste sent to land fills. Fields Hot Appliec .. 'ips your ; ob site clean of asphalt and carton debris. With Fields Hot Applied Asphalt, th. s . ::ar open cardboard cartons and to chop apart the conventional 100 pound asphalt p;uE ;r ; ;ted Since employees are no longer required to use axes, axe injuries are eliminated..;:_ ac : njuries Fre reduced because the 50 pound MeltPac brick is half the weight of the 100 pound a:•ph•ar: kegs for employees to lift. About Fle•c.: • F_� , ct Guide , ,iwertisiny BUR Systems Copyright C : > any, LLC.. rights reserved. Type 1,2,3,4 Hot MSDS > http: / /wwv- .; i, •.. ;; rat/ com merciaUnroductsr'nrodlnih/hntni html diznnnno June 17, 2010 Dear Mr. Henderson, City of Tu F'`c. ` 11 Jim Haggerton, Mayor Department of Community Development Ken Henderson McDonald & Wetle Roofing, Inc 9420 39 Ave Ct SW Lakewood, WA 98499 RE: Request for Extension #2 Development Permit No D09 -103 RREEF Properties —12610 Interurban Ave S This letter is in response to your written request for an extension to Permit Number D09 -103. The Acting Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending your permit an additional 30 days from the date of expiration, through July 21, 2010. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, File: Permit No. D09 -103 W:\Permit Center\Extension Letters\Pennits\2009\D09 -103 Permit Extension #2.doc Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 6 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 KEN HENDERSON, GENERAL MANAGER MCDONALD & WETLE ROOFING, INC. 9420 39 AVE. CT. SW LAKEWOOD, WA., 98499 June 11, 2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard #100 Tukwila, Washington 98188 206 -431 -3670 206 - 431 -3665 fax Attention: Bill Rambo RE: Permit No. D09 -103 12610 Interurban Ave. S. Tukwila McDonald & Wetle Roofing, Inc. is requesting another extension to allow for better weather conditions to accomplish the Seismic work to be performed on this project. Help in this matter will be greatly appreciated. Thank you, X e4 - •--/ Ken Henderson General Manager rE,S to-c)-1- t 41- 01121 b Il) bliiezei 5ocl RECEIVED JUN 112010 )1x64- PERMIT CENTER d i e904/2a/e 1111M .TAN rTl -4ki 1'11d PH. 253- 589 -8999 Fax 253 - 589.9025 L r counald ode MCDONWR9440W C7MGLOCCC7 71A!77 c TG 7 /QT /QLI KEN HENDERSON 9420 39 AV CT SW LAKEWOOD WA 98499 City of Tukwila Department of Community Development RE: Permit No. D09 -103 12610 INTERURBAN AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 06/21/2010. Based on the above, you are hereby advised to: Sincerely, 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- Jim Haggerton, Mayor Jack Pace, Director 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 06/21/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Bill Rambo Permit Technician File: Permit File No. D09 -103 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 KEN HENDERSON 972039 AV CT SW LAKEWOOD WA 98499 Dear Permit Holder: Sincerely, Bill Rambo Permit Technician File: Permit File No. D09 -103 City of Tukwila Jim Haggerton, Mayor Department of Community Development RE: Permit No. D09 -103 12610 INTERURBAN AV S TUKW Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/23/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 03/23/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 March 9, 2010 Ken Henderson McDonald & Wetle Roofing, Inc 9420 39 Ave Ct SW Lakewood, WA 98499 RE: Request for Extension Development Permit No D09 -103 RREEF Properties —12610 Interurban Ave S Dear Mr. Henderson, This letter is in response to your written request for an extension to Permit Number D09 -103. The Acting Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending your permit an additional 90 days from the date of expiration, through June 21, 2010. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, + ifer Marshall it Technician File: Permit No. D09 -103 epartment of Community eVelopment Jack Pace, Director W:\Pemnt Center\Extension Letters\Permits\2009\DO9 -103 Permit Extension.doc Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 KEN HENDERSON, GENERAL MANAGER MCDONALD & WETLE ROOFING, INC. 9420 39 AVE. CT. SW LAKEWOOD, WA., 98499 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, #100 Tukwila, Washington 98188 206 -431 -3670 206 -431 -3665 fax Attention: Bill Rambo Permit Technician RE: Permit No. D09 -103 12610 Interurban Ave. S. Tukwila McDonald & Wetle Roofing, Inc. is requesting a 90 day extension to allow for better weather conditions to accomplish the Seismic work to be performed on this project. Help in this matter will be greatly appreciated. Ken Henderson Gen. Mgr. N. Pres. FCEIVIED MAR 04 2O1 COMM w )EVELoomemar PH. 253 - 589 -8999 Fax 253 - 589 -9025 cDonald etle MCDONWR944DW Ea- e 3 -13 -10 66-6417 0(0 I (Ot. o ACTIVITY NUMBER: D09 -103 DATE: 06 -18 -09 PROJECT NAME: RREEF PROPERTIES SITE ADDRESS: 12610 INTERURBAN AV S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: n . Bui ing'Division h�� Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS RO TING: Please Route Structural Review Required No further Review Required ❑ REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documentshouting slip.doc 2 -28 -02 � PERMIT COORD COP1PSI PLAN REVIEW /ROUTING SLIP Structural Approved with Conditions , Fire Prevention Incomplete ❑ DATE: DATE: Planning Division Permit Coordinator DUE DATE: 06-23-09 Not Applicable DUE DATE: 07-21-09 Not Approved (attach comments) n U Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status VANCOSM920LW VANCO SHEET METAL INC CONSTRUCTION CONTRACTOR SHEET METAL UNUSED 6/16/20086/16/2010 03/16/2006 ACTIVE ARROWRS034KK ARROW ROOFING Et SHEET MTL INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 5/12/19974/25/2011 ACTIVE PIONESM088DE PIONEER SHEET METAL INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 3/5/1992 2/24/2010 ACTIVE MCDONWI161JS MCDONALD & WETLE INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 4/10/198412/31/2009ACTIVE ABCRO**3440K ABC ROOFING CO INC CONSTRUCTION CONTRACTOR ROOFING UNUSED 9/12/1966 11/29/2009 ACTIVE Name Role Effective Date Expiration Date NATIONALREGISTERED AGENTS INC AGENT 03/16/2006 BOLT, ROBERT E PRESIDENT 03/16/2006 HENDERSON, KENNETH VICE PRESIDENT 03/16/2006 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MCDONALD & WETLE ROOFING INC Phone 5036670175 Status ACTIVE Address 9420 39TH AVE CT SW License No. MCDONWR944DW Suite /Apt. License Type CONSTRUCTION CONTRACTOR City LAKEWOOD Effective Date 3/16/2006 Expiration Date Zip 98499 Suspend Date State WA County PIERCE Business Type Corporation Parent Company UBI No. 602576757 3/17/2010 Specialty 1 GENERAL Specialty 2 UNUSED Other Associated Licenses Business Owner Information • • Page 1 of 2 https: // fortress .wa.gov /lni/bbip/Detail.aspx 07/01/2009