Loading...
HomeMy WebLinkAboutPermit D09-111 - AVIATION PARTNERS BOEING - TENANT IMPROVEMENTThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. D09 -111 Aviation Partners Boeing 2811 South 102nd Street RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # tode Exemption = Brief Explanatory DeSctiptiop �t�tutel ule The Privacy Act of 1974 evinces Congress' intent that Personal Information — social security numbers are a private concern. As such, individuals' social security numbers are Social Security Numbers redacted to protect those individuals' privacy pursuant 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. to 5 U.S.C. sec. 552(a), and are also exempt from 552(a); RCW 552(a); RCW disclosure under section 42.56.070(1) of the 42.56.070(1) 42.56.070(1) Washington State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card Personal Information — numbers, electronic check numbers, credit expiration 38 DR2 Financial Information — dates, or bank or other financial account numbers, RCW RCW 42.56.230(4 5) which are exempt from disclosure pursuant to RCW 42.56.230(5) 42.56.230(5), except when disclosure is expressly required by or governed by other law. AVIATION PARTNERS BOEING 2811 S 102 ST D09 -111 Parcel No.: 0423049190 Address: 2811 S 102 ST TUKW Suite No: Tenant: Name: AVIATION PARTNERS BOEING Address: 2811 S 102 ST, STE 200 , TUKWILA WA Cityef Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us DEVELOPMENT PERMIT Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTERN'L BLVD , FOURTH FLOOR 98168 Phone: Contact Person: Name: MARCUS MCFARLAND Address: 12201 TUKWILA INTERNATIONAL BL , TUKWILA WA 98168 Phone: 206 730 -6578 doc: IBC -10/06 * * continued on next page ** Permit Number: D09 -111 Issue Date: 07/20/2009 Permit Expires On: 01/16/2010 Contractor: Name: SABEY CONSTRUCTION INC. Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA 98168 Phone: 206 - 281 -4700 Contractor License No: SABEYCI033KM Expiration Date: 01/06/2011 DESCRIPTION OF WORK: TENANT IMPROVEMENT OF 28,990 SF. CONSTRUCTION OF NEW WALLS, RELOCATION OF LIGHTS, AND INSTALLATION OF NEW DOORS AND CARPET. Value of Construction: $928,062.00 Fees Collected: $12,155.17 Type of Fire Protection: International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0008 D09 -111 Printed: 07 -20 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City oltTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D09 -111 Issue Date: 07/20/2009 Permit Expires On: 01/16/2010 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or a erformanc of or am thorized to sign and obtain this development permit. Signature: Date: '-7ee /�,2. °Oq Pi Print Name: //"f c`:14 y1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 <f �� Date: P)'--()/ D09 -111 Printed: 07 -20 -2009 Parcel No.: 0423049190 Address: Suite No: Tenant: 2811 S 102 ST TUKW • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us AVIATION PARTNERS BOEING 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D09 -111 ISSUED 06/29/2009 07/20/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 D09 -111 Printed: 07 -20 -2009 ® • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 25: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 26: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) doc: Cond -10/06 D09 -111 Printed: 07 -20 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 27: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 28: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 29: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 30: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 31: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 32: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 33: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 34: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 35: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 36: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 37: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 39: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 40: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 41: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 42: To schedule all construction fire - related inspections send an e -mail to fireinsprequest @ci.tukwila.wa.us. Include your doc: Cond -10/06 D09 -111 Printed: 07 -20 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us name, telephone number, permit number, project name and address and type of inspection requested. 43: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes such condition or violation. 44: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila (206)575 -4407. * * continued on next page ** doc: Cond - 10/06 D09 - 111 does not imply approval of Fire Prevention Bureau at Printed: 07 -20 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: # 1 G r doc: Cond -10/06 D09 -111 Date: 7 /X ordinances governing or local laws regulating Printed: 07 -20 -2009 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hap://www.ci.lulcwila.wa.us Site Address: 2811 South 102nd Street Tenant Name: Aviation Partners Boeing Property Owners Name: Riverfront Technical Park LLC Mailing Address: 12201 Tukwila International Blvd, 4th Floor Name: Marcus McFarland Mailing Address: 12201 Tukwila International Blvd, 4th FL000r E -Mail Address: marcusm @sabey.com Company Name: Sabey Construction Mailing Address: 12201 Tukwila International Blvd. 4th Floor Contact Person: Glenn Parry E -Mail Address: glennp @sabey.com Contractor Registration Number: SABEYC1033KM Company Name: Burgess Design Mailing Address: 1326 5th Ave. Suite 500 Contact Person: Kip Kolodziejski E -Mail Address: KipK @burgessdesign.net Tukwila City Tukwila Seattle I Building Permit No. D01 'M Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 0423049190 Suite Number: Floor: New Tenant: 0 Yes WA State CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: (206) 730 -6578 Tukwila WA 98168 City State Fax Number: (206) 282 -9951 2 ❑ ..No 98168 Zip Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) WA 98168 City State Zip Day Telephone: (206) 7304983 Fax Number: (206) 282 -9951 Expiration Date: 01/12/2011 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record City State Day Telephone: (206) 587 -7120 Fax Number: (206) 587 -7122 WA 98101 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H: Wpplications\Fonns- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised - . 1 -2009 bh State Zip Page 1 of 6 r I BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 928,062 Existing Building Valuation: $ 15,980,000 Scope of Work (please provide detailed information): Tenant improvement of 28,990 square. Construction of new walls, relocation of lights, installation of new doors and carpet. Will there be new rack storage? ❑ Yes SEPTIC SYSTEM ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If `yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: m Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If' yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 "paper including quantities and Material Safety Data Sheets. ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\ Forms- Appliw"ons On Line \2009 Applications \t -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor 87,500 5N B 2 "a Floor 87,500 28,990 5N B 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck r I BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 928,062 Existing Building Valuation: $ 15,980,000 Scope of Work (please provide detailed information): Tenant improvement of 28,990 square. Construction of new walls, relocation of lights, installation of new doors and carpet. Will there be new rack storage? ❑ Yes SEPTIC SYSTEM ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If `yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: m Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If' yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 "paper including quantities and Material Safety Data Sheets. ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\ Forms- Appliw"ons On Line \2009 Applications \t -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING W ILDING O ER OR AV D AG NT: Si g nature: `/4 A "' � Print Name: Marcus McFarland Mailing Address: 12201 Tukwila International Blvd. 4th Floor Date Application Expires: Date Application Accepted: adim 0‘ H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Day Telephone: (206) 730 -6578 Tukwila WA 98168 City • Date: 06/29/2009 State Staff Initials: Zip Page 6 of 6 Parcel No.: Address: Suite No: Applicant: Receipt No.: R09 -01418 Initials: User ID: Payee: doc: Receiot -06 0423049190 2811 S 102 ST TUKW AVIATION PARTNERS BOEING WER 1655 Payment Credit Crd MC Authorization No. 001916 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us SABEY CORPORATION TRANSACTION LIST: Type Method Descriptio ACCOUNT ITEM LIST: Description Account Code PLAN CHECK - NONRES 000/345.830 RECEIPT Amount 60.00 Total: $60.00 Permit Number: Status: Applied Date: Issue Date: Payment Amount: $60.00 D09 -111 ISSUED 06/29/2009 07/20/2009 Payment Date: 09/10/2009 10:09 AM Balance: $0.00 Current Pmts 60.00 y:tENT ECEIVE Printed: 09 -10 -2009 Receipt No.: R09 -01216 Initials: JEM User ID: 1165 Payee: MARCUS MCFARLAND Payment Cash Authorization No. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0423049190 Permit Number: D09 -111 Address: 2811 S 102 ST TUKW Status: ISSUED Suite No: Applied Date: 06/29/2009 Applicant: AVIATION PARTNERS BOEING Issue Date: 07/20/2009 TRANSACTION LIST: Type Method Descriptio Amount 60.00 Account Code Current Pmts 000/345.830 60.00 Total: $60.00 Payment Amount: $60.00 Payment Date: 08/04/2009 08:55 AM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 08 -04 -2009 Parcel No.: 0423049190 Permit Number: D09 -111 Address: 2811 S 102 ST TUKW Status: APPROVED Suite No: Applied Date: 06/29/2009 Applicant: AVIATION PARTNERS BOEING Issue Date: Payment Amount: $7,368.54 Initials: BLR Payment Date: 07/20/2009 04:36 PM User ID: ADMIN Balance: $0.00 Receipt No.: R09 -01132 Payee: SABEY CORPORATION • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 114991 7,368.54 Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 640.237.114 RECEIPT Account Code Current Pmts 7,364.04 4.50 Total: $7,368.54 Y ENT RECEIVED doc: Receiot -06 Printed: 07 -20 -2009 Receipt No.: R09 -00995 Initials: User ID: Payee: ACCOUNT ITEM LIST: Description doc: Receipt -06 JEM 1165 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 0423049190 Permit Number: D09 -111 Address: 2811 S 102 ST TUKW Status: PENDING Suite No: Applied Date: 06/29/2009 Applicant: AVIATION PARTNERS BOEING Issue Date: SABEY PROPERTIES LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 114773 4,786.63 Authorization No. PLAN CHECK - NONRES 000/345.830 RECEIPT Account Code Current Pmts 4,786.63 Total: $4,786.63 Payment Amount: $4,786.63 Payment Date: 06/29/2009 12:22 PM Balance: $7,368.54 PAYMENT RECEIVED Printed: 06 -29 -2009 Project: - /A6/ /d A/ ig*if / .) Type of Inspection: 14 �/n./4L ( /C / /O/)MMENTSS: z q A Date Called: Special Instructions: • r %p /7'1 c 3G/70 r _ o Date C W fante� S /� S p.m. Requester: Phone No: c?Oc,- - //,6c, 3) / 2 ,4Ai. t (d1.$/, /07' /A: ;$ d e ye z,, - 4oi4.4e, \ Project: - /A6/ /d A/ ig*if / .) Type of Inspection: 14 �/n./4L Address: S3// ,s _ /02. s Date Called: Special Instructions: • r %p /7'1 c 3G/70 r _ o Date C W fante� S /� S p.m. Requester: Phone No: c?Oc,- - //,6c, E Approved per applicable codes. INSPECTION RECORD Retain a copy with permit IN PECTION NO. CITY OF TUKWILA BUILDING DIVISI 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. 6 1 ON (206)431 -36 '0 Corrections required prior to approval. Da d s— ( ho REINSPECT! N FEE RE(iUIRED. Prior to inspection, fee must be id at 6300 Southc nter Blvd., Suite 100. Call to schedule reinspection. eceipt No.: 'Date: Project: A WA - lob ?A( KSfes Type of Inspection: (, LA za N c:. Address: Fill S (O2 r Date Called: Special Instructions: o 366'1 ' 0 ( Date Wanted: 9- Z ; .-09 a . p .m Requester: Phone No: 7 n C) -2 -- ii 8( ) gag -)1 INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY F TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2'06)431 -3670 El Approved per applicable codes. Ekorrections required prior to approval. c COMMENTS: "Th _ D vy\ - .\/..3-1..C.... v,..1-c ev—\ .' ; 1 tor: Gam., $61 .00 REINSPECTION FEE pain at 6300 Southcenter Bl Re -ip No.: Date: EQUIRE o. Prior to inspection, fee must be d., Suite 00. Call to schedule reinspection. Date: Pro' i �' / � >L/ N�Q Type of Inspection: ..." 4 f' 4 Ad Date Called: / Special Instructions: /Pi Date nted 9 4r it Requester: Phone No: INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPE.'10. NO. CITY • F TUKWILA BUILDING DIVISION 19— 6300 Southcenter Blvd., #100, Tukwila, WA 98188 • (206)431 -3 7 04 1/4 I I A per applicable codes. Corrections required prior to approval. COMMENTS: p i Date: 9 -2-v 60 0 REINSPECTI I FEE R UIRED. Prior to inspection, fee, must be at 6300 Southcenter Blv , Suite 'l0% Call to schedule reinspestion. Recei No.: Date: Proj ct: PIr aN ra /S Type of Inspection: - .s7 (?i / ,h. Address: z C / Aa 2 Date Ca Spec Instructions: Date Wanted ' tt�� a.m. V Requester. Phone No: Y25 --315 _ 8 30 z 3 COMMENTS: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. Corrections required prior to approval. Pb-rpf /14;d 1i& S SltialeLD/ ,4Y' 1/ Date: b/ PERMIT NQ� (206)431-3670 i ri 60 '0 REINSPECT! N FEE RE UIRED. for to inspection, fee must be pa' • at 6300 Southcenter Blvd. Suite 1 O. Call to schedule reinspection. Re pt No.: (Date: Project: // 4 r R /7Al�r� /,.� jh Type of Inspection: sp /: �( Address: Date Called: Special Instructions: Date Wanted: �-f --- ,2- a, p.m. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION F- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 0- i3 a/A Insp or: 60.00 REINSPECTION paid at 6300 Southcenter BE eceipt No.: INSPECTION RECORD Retain a copy with permit E R O UIRED. Prior to.inspection, fee must be ., Suite 100. Call to schedule reinspection. Date: b ag= PERMIT NO. COMMENTS: / RTA1 BOe 0 3 ,,9. jq raVe1 ...„47 i,,l � ... ,,, (7.✓� , f „/.0,7 a -e Jeri &1+ 7Lr) / A l s p a - - / — i o a / ) / ? ' . S - t f7 /</ %) Kid ✓Ce C4# 9 // s - Date Wanted: - �_ v S' a m� p.m. Requester: Phone No: DG - 2.5 - 5 -. - //9U Project: 4v /4 A 7N / RTA1 BOe Type of Inspection: /A/6 — 1 .6 Address: 01 all 5 AO sI Date Called: Special Instructions: Date Wanted: - �_ v S' a m� p.m. Requester: Phone No: DG - 2.5 - 5 -. - //9U INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. El Corrections required prior to approval. Dat - 0 REINSPECTION4FEE R QUIRED. Prior to inspection, fee must be at 6300 Southcent. r Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: ,,,,b ,A„ P, ,_�, 674 Type of Inspection: r► ioct, - Address: 2 r r 5. I o.. Si Suite #: zu a _ _ _ _ Contact Person: A Nx-,- ,,4 ,rirs�, Special Instructions: Phone No.: f 1 Needs Shift Inspection: 4404/4/6 no Mil - Sprinklers: y Fire Aiarm: . ,rirs�, Hood & Duct: AJ - Monitor e ,L4,,sN t, iter Pre -Fire: Permits: Occupancy Type: R INSPECTION NUMBER pproved per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT If _ PERMIT NUMBERS dover Park East, Tukwila, Wa: 98188 206 -575 -4407 a Corrections required prior to approval. COMMENTS: d/L Ufa d C c_ v y PEN 0/p6 Rt DG it efi o ns ector: f iti $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. I Date: Q /i¢ / Hrs.: • 1/13/06 T.F.D. Form F.P. 113 COMMENTS: , A r , of s Type of Inspection: r °; f,, .. It; /.5>r ' /i1c - c.. , Address: z , t r Suite #: r ; 7_ ‘.7.7 Contact Person: Special Instructions: Phone No.: .l l P L! / r'i K Oil 01) OW 13/1( C r/ - ?A ,s : , • G IL _ I ._ - ��.. 1 fr. i�u�e v Y= Ski''�,1E 4, ': �;� i� 1;'i Project: .,, . , A r , of s Type of Inspection: r °; f,, .. It; /.5>r ' /i1c - c.. , Address: z , t r Suite #: r ; 7_ ‘.7.7 Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type:_. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Approved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS Corrections required prior to approval. Inspector: Date: Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 July 10, 2009 Department of Community Development Jack Pace, Director Marcus McFarland 12201 Tukwila International BI 4 Floor Tukwila WA 98168 RE: CORRECTION LETTER #1 Development Permit Application Number D09 -111 Aviation Partners Boeing — 2811 S 102 St Jim Haggerton, Mayor Dear Mr. McFarland, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time the Building, Fire, and Planning Departments have no comments. Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. I have also enclosed a Non - Residential Sewer Use Certification that must be completed prior to issuance of the permit. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File No. D09 -111 W:\Permit Center\Correction Letters V009009-111 Correction Letter #1.DOC wer l, 2nn Gnthnnn R m1lvvn rd Quito it inn o Trr 4uiila Wa chinotnn OR1RR e PhnnP• 2nh- 4 _ 3h717 a Fax. 2(Ih -4 ?1 ?hhS 0 • PUBLIC WORKS DEPARTMENT COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards DATE: June 30, 2009 PROJECT: Aviation Partners Boeing 2811 S 102 St PERMIT NO: D09 -111 REVIEW NO: 1 PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. 1) Your permit application calls for 28,990 sq ft tenant improvement. Please provide the following information in writing: a) who was the previous occupant(s) /tenant(s) of the above space b) how long was the subject space or part of it vacant. 2) If the subject space or part of it was vacant for more than one (1) year, the applicant shall fill out the attached Traffic Concurrency Certificate Application and pay to Public Works the appropriate fee per table on the second page of this application. P: Joanna/Comments 1 D09 -111 SABEY • Correction Letter # 1 Project: Aviation Partners Boeing Permit #: D09411 Plan Reviewer: Joanna Spencer 1) CONSTRUCTION a. Previous tenant was Sato Travel b. The space has been vacant for 4 years 2) See attached Traffic Concurrency Certificate Application. 7(2.( oirfu CORREQ SIR* PERMANENT FILE COPYWq 0 vim I Fitz AA- op, A R C H I T E C T U R E Sabey Construction Inc. 206/281 -4200 main line C O N S T R U C T I O N 12201 Tukwila International Blvd., 4th Floor 206/281 =0920 fax 'line D E V E L O P M E N T Seattle,Washington 98168 -5121 www.sabey.com RECEIVEr JUL . 14 2009 PERMIT CENTE_ Anthony Vincent jay' -ii/ From: Amador, Anthony [aamador @simplexgrinnell.com] Sent: Thursday, September 24, 2009 10:44 PM To: Anthony Vincent Subject: Riverfront tech park fire system I have completed the fire alarm changes for the shutdown for hvac units. They are all shutting down under General Alarm From bldg alarm. Thanks ,Tony A. Simplex Grinnell TR ECEIVE 2 2009 DEP DEPARTMENT. l 'o Bui Ing Division Public Works Complete Comments: APPROVALS O CORRECTIONS: Documents/routing slip.doc 2 -28 -02 � PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D09 -111 DATE: 09 -01 -09 PROJECT NAME: AVIATION PARTNERS BOEING SITE ADDRESS: 2811 S 102 ST Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 2 After Permit Issued Fire Prevention ❑ Structural ❑ Permit Coordinator DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Incomplete n TUES/THURS ROUTING: Please Route n Structural Review Required n REVIEWER'S INITIALS: Planning Division DUE DATE: 09-03-09 DATE: DATE: Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DUE DATE: 10-01-09 Approved Approved with Conditions Ti Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: �"q Building Div' v p A1S N lir Public Works TUES/THURS ROUTING: Please Route ❑ Structural Review Required APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D09 -111 DATE: 07 -23 -09 PROJECT NAME: AVIATION PARTNERS BOEING SITE ADDRESS: 2811 S 102 ST Original Plan Submittal Response to Incomplete Letter # _ Response to Correction Letter # X Revision # 1 After Permit Issued AM Ai /4 7c* Fire Prevention Structural Complete ❑ Incomplete ❑ N /4 -v7 Planning Division Permit Coordinator IN DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07-28-09 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required n REVIEWER'S INITIALS: DATE: DUE DATE: 08 -25-09 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: 04 Bui Wurks lding Division i ili Wbrks b � "E • PLAN REVIEW /ROUTING SLIP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 Fire Prevention Structural Incomplete n ACTIVITY NUMBER: D09 -111 DATE: 07 -14 -09 PROJECT NAME: AVIATION PARTNERS BOEING SITE ADDRESS: 2811 S 102 ST Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued Planning Division ❑ Permit Coordinator DUE DATE: 07 -16-09 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route IN Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 08-13-09 n i4, Approved ❑ Approved with Conditions I Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D09 -111 DATE: 06 -29 -09 PROJECT NAME: AVIATION PARTNERS BOEING SITE ADDRESS: 2811 S 102 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: NTS: Biai ding Di Public W5 - rks DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 () PERMIT COORD COPY 111 PLAN REVIEW /ROUTING SLIP ;u m ac' & 4 d1 Fire Prevention Structural Incomplete Gth 0(1 Planning Division Permit Coordinator ❑ DUE DATE: 06-30-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS R TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 07-28-09 Approved ( Approved with Conditions Not Approved (attach comments) U Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only (� CORRECTION LETTER MAILED: �" t D O I Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS STAFF INIT LS ISSUED DATE STAFF INITIALS 1 1 3-01 Summary of Revision: iipl ilroWq, ic,G (T 6- &- Q(, Oil ON oC (r, Summary of Revision: -e LOcc LI lt.4.4 not Received by: , (/Ul ai'c.<._ s M9 / REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 2- 01 • of - aI— Summary of Revision: iipl ilroWq, ic,G (T 6- &- Q(, Received by: iN .4. REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS S ummary of Revision: Received by: 1 c PROJECT NAME: flu La-4 w Va v\eits PERMIT NO: J09' 1 i SITE ADDRESS: �.g \ S 1 S t ORIGINAL ISSUE DATE 1 REVISION LOG (please print) / (please print) (please print) (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http.: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: September 1, 2009 Plan Check/Permit Number: D09 -111 O Response to Incomplete Letter # O Response to Correction Letter # • Revision # 2 after Permit is Issued O Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: Aviation Parnters Boeing 2811 South 102 Street Tukwila, WA 98168 Marcus McFarland Entered in Permits Plus on H: Applications\Forms- Applications On Line\2009 -08 Revision Submittal.doc Created: 8-13-2004 Revised: 8 -2009 • REVISION SUBMITTAL e Ee rt (EP 01 zoos PERMIT CENTER Phone Number: (206) 730 -6578 Summary of Revision: Revision to egress plan. Additional exit was added. Sheet Number(s): G.0.3 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Date: July 23, 2009 Project Name: Project Address: Contact Person: Glenn Parry \applications \forms - applications on Iine \revision submittal Created: S -13 -2004 Revised: 1 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us i REVISION SUBMITTAL i Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Aviation Partners Boeing 2811 South 102nd Street Plan Check/Permit Number: D09 -111 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # • Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Sheet Number(s): G.03, A.2A.1, A.2B.1, A.2C.1, A.2D.1 & A.9.1 "Cloud" or highlight all areas of revision includin ! i of revisi Received at the City of Tukwila Permit Center bby: 7-)- Entered in Permits Plus on , Phone Number: (206) 730 -4983 Summary of Revision: Changes to wall layout and locations for offices. RECEIVED CITY OF TUKWILA JUL 2 3 2009 "SIR Date: 7/14/2009 Entered in Permits Plus on 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: D09-111 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: AVIATION PARTNERS BOEING Project Address: 2811 S 102 St Contact Person: Marcus McFarland Phone Number: 20 - 730 -6578 Summary of Revision: Responses attached to the Public Works Dept correction letter #1. Sheet Number(s): N/A "Cloud" or highlight all areas of revision including date of revisiRn Received at the City of Tukwila Permit Center by: \applications\forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director RECEIVED CITY OFTUKVVILA JUL 14 zuO9 PERMIT CENTER License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SABEYC*953RE SABEY CORPORATION CONSTRUCTION CONTRACTOR GENERAL UNUSED 12/5/2005 12/5/2009 ACTIVE DASCOC *066KD D A S CONSTRUCTION CORP CONSTRUCTION CONTRACTOR GENERAL UNUSED 5/4/1994 5/4/1997 ARCHIVED BERKLCI088CE BERKLEY CONSTRUCTION INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 2/5/1992 2/5/1993 ARCHIVED ARCHIDG132QZ ARCHITECTUAL DEV GROUP INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 11/9/1987 11/9/1992 ARCHIVED SABEYC*141PH SABEY CORPORATION CONSTRUCTION CONTRACTOR UNUSED GENERAL 10/8/1986 12/31/2001 ARCHIVED OWPROI "221 RR 0 Et W PROPERTIES INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 12/19/1978 10/1 /1986 ARCHIVED BERKLS *267LP BERKLEY STRUCTURES INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 6/17/1974 12/31/1991 ARCHIVED Untitled Page General /Specialty Contractor A business registered as a construction contractor with Ll'tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company SABEY CONSTRUCTION INC 2062814200 12201 TUKWILA INTL BLVD 4TH FLOOR SEATTLE WA 981685121 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601532164 ACTIVE SABEYCI033KM CONSTRUCTION CONTRACTOR 5/14/1997 1/12/2011 GENERAL UNUSED Other Associated Licenses Business Owner Information 0 https: // fortress .wa.gov /lni/bbip/Detail.aspx • Page 1 of 3 07/20/2009 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 HARTFORD FIRE INSURANCE CO 52BSBCQ3983 12/31/2004 Until Cancelled $6,000.00 $12,000.00 12/20/2004 4 TRAVELERS CAS a SURETY CO 815103354851 BCM 12/31/2001 12/31/2004 $12,000.00 12/24/2001 3 TRAVELERS CAS a SURETY CO OF A 815103354851 BCM 12/31/2000 12/31 /2001 $6,000.00 12/14/2000 2 UNITED PACIFIC INS CO U2800451 05/04/1998 Until Cancelled 02/15/2001 $6,000.00 01/16/2001 1 UNITED PACIFIC INS CO U2800451 05/04/199605/04 /1998 $6,000.00 Savin s g Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 04/21/1994 03/19/1998 Bond 05/01/2010 $6,000.00 Name Role Effective Date Expiration Date SABEY, DAVID A Cancel Date 01/01/1980 Amount POOLE, LAURENT D 16 01/01/1980 2094156387 HARMON, JAMES N 05/01/2010 01/01/1980 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 16 NATIONAL FIRE INS CO OF HART 2094156387 11/01/2008 05/01/2010 $1,000,000.0011 /03/2008 15 NATIONAL FIRE INSURANCE COMPAN 2094061165 11/01/200811/01 /2009 $1,000,000.0010 /24/2008 14 NATIONAL FIRE INS CO OF HARTFO 2094061165 11/01/200711/01 /2008 $1,000,000.0012 /07/2007 13 NATIONAL FIRE INS 2079747865 12/31/2004 12/31 /2007 $1,000,000.00 01/12/2006 Untitled Page Bond Information Assignment of Savings Information Insurance Information li • Page 2 of 3 https : // fortress. wa. gov /lni/bbip/Detai 1. aspx 07/20/2009 A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKINILLA, WA 98168 burgess design J interiors o architecture 1326 Fifth Aveeue Suite 500 . Se . WA 08101 TEL: 206.587.7120 AX:206. 587.7122 M reproduction & intellectual property rights reserved c 2009 Professional seal Flan review approval is subject to errors and °mks Approval of ction • ents does not the violation of any adopted code or ordinance. Receipt of approve4 eld Copy an irs ons is acknowledged By I Data: °Willc):Gf TpurvisPiow No Issue Description REVIEW SET PERMIT SET A REVISION 1 44. REVISION 2 Drawn by: MK/TS Reviewed by: Project No: 09-S804-00 RECEIVED JUL 2 3 21:109 PERMIT CENTER EvISIONS No ch .---", Sh2 .' r to the scope • 1 Of Ttilc Sucrg LIVIS.. NOTE: Revisions will require a new plan submittal / and may include additional plan review fees. SEPARATE PERMIT RE:IRED FOR: 44: FE"Ornbing :VGas Piping City of Tukwila BUILDING DIVISION REGISTERED I ARCHITECT KI LODZIEJSKI STATE OF WASHINGTON Date 6/22/09 6/25/09 07/15/09 07/22/09 KK COVER SHEET / PROJECT INFORMATION Original drawing is 30" x 42". Scale entities accordingly if reduced GOO GENERAL NOTES ARCH / INTERIOR ABBREVIATIONS BUILDING SUMMARY PROJECT TEAM 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT "GENERAL CONDITIONS," AND BUILDING STANDARDS AS PROVIDED BY THE BUILDING OWNER. 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT TRADES. 3. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. 4. CONTRACTOR INITIATED CHANGES SHALL BE SUBMMTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWING ONLY WILL NOT SATISFY THIS REQUIREMENT. 5. ALL MODIFICATIONS, REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS AUTHORIZED IN WRITING BY OWNER AND/OR ARCHITECT. 6. WITHIN FIVE (5) BUSINESS DAYS OF START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY IN WRITING BOTH THE ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD TIMES, PAYMENT OF RUSH FABRICATION OR DEUVERY CHARGES OUT OF SEQUENCE INSTALLATION, OR DELAY OF INSTALLATION OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. 8. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS. 9. THE USE OF WORD "PROVIDE" SHALL ALWAYS MEAN, "FURNISH AND INSTALL, CONNECT, OR SECURE" AS REQUIRED. 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL INCLUDE DELIVERY LEAD TIMES OF CONSTRUCTION ITEMS, AND START AND COMPLETION DATES OF EACH PHASE. THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS. 13. ACCESS TO AND FROM THE PROJECT SITE, SPECIAL CONDITIONS, NOISY WORK, TIMING OF WORK, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, RELOCATION OF EXISTING EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC., MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. 14. ADEQUATE CLEANUP, PROTECTION AND PLACEMENT OF ANY CEILING TILES AND/OR OTHER DISRUPTION TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT THE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS. 15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: COMMON HALLWAYS, FREIGHT ELEVATOR VESTIBULES, ETC. 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 17. UPON COMPLETION OF ALL CONSTRUCTION, THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH ONE SET OF "RECORD" AS-BUILT DRAWINGS. 18. ALL MATERIALS TO BE NEW UON. 19. PATCH ALL DISTURBED AND/OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS REQUIRED FOR FINISHED APPEARANCE. 20. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY BACKING, BLOCKING, AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL FIXTURES, CASEWORK AND ALL OTHER ITEMS REQUIRING IT. 21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. 22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND REQUIRE ARCHITECT'S REVIEW PRIOR TO INSTALLATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW. 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION. SUBMIT TO ARCHITECT AT LEAST THREE (3) COPIES FOR REVIEW. 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE LIST. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. ADJ - ADJUSTABLE MECH - MECHANICAL AFF - ABOVE FINISH FLOOR MEZZ - MEZZANINE ALT - ALTERNATE MFR - MANUFACTURER ALUM - ALUMINUM MIN - MINIMUM APC - ACOUSTICAL PANEL CEILING MISC - MISCELLANEOUS APPROX - APPROXIMATE ARCH - ARCHITECTURAL MTD - MOUNTED ACT - ACOUSTICAL CEILING TILE MTL - METAL AV - AUDIO VISUAL N/A - NOT APPLICABLE BLDG - BUILDING NIC - NOT IN CONTRACT BOT - BOTTOM NTS - NOT TO SCALE CAB - CABINET OC - ON CENTER CL - CENTER LINE OFF - OFFICE CLG - CEILING OPNG - OPENING CLR - CLEAR OVHD - OVERHEAD COL - COLUMN P - PAINT CONC - CONCRETE PART - PARTITION F IRE R E S ISTIVE CONF - CONFERENCE PERF - PERFORATED DEMO - DEMOLITION PERIM - PERIMETER DEPT - DEPARTMENT PERP - PERPENDICULAR DF - DRINKING FOUNTAIN PLAM - PLASTIC LAMINATE DIA - DIAMETER PLYWD - PLYWOOD DIFF - DIFFUSER QTY - QUANTITY DIM - DIMENSION (R) - RELOCATED DTL - DETAIL DW - DISHWASHER RA - RETURN AIR RCP - REFLECTED CEILING PLAN DWG - DRAWING EA - EACH REC - RECESSED REF - REFERENCE - EL ELEVATOR ELEC - ELECTRICAL REFR - REFRIGERATOR ELEV - ELEVATION REL - RELOCATE EQ - EQUAL REV - REVISION OR REVISED EQUIP - EQUIPMENT RM - ROOM Da - EXTERIOR RO - ROUGH OPENING RTD - RATED FA - FIRE ALARM FD - FLOOR DRAIN SCHED - SCHEDULE FE - FIRE EXTINGUISHER SF - SQUARE FEET/FOOT FEC - FIRE EXTINGUISHER CABINET SHT - SHEET FFE - FINISH FLOOR ELEVATION SIM - SIMILAR FI/-TIN ■O FIN - FINISH SPEC - SP ECIC FLUOR - FLUORESCENT SPKLR - SPRINKLER FLR - FLOOR SPKR - SPEAKER FO - FACE OF SQ - SQUARE FOIC - FURNISHED BY OWNER, INSTALLED STD - STANDARD BY CONTRACTOR STL - STEEL FTIC - FURNISHED BY TENANT, INSTALLED STOR - STORAGE BY CONTRACTOR FURR - FURRING STRL - STRUCTURAL GA - GAUGE STRUC - STRUCTURAL SYMM - SYMMETRICAL GC - GENERAL CONTRACTOR GL - GLASS TBD - TO BE DETERMINED GWB - GYPSUM WALLBOARD TEL - TELEPHONE OR TELECOM TEMP - TEMPERED HC - HANDICAPPED THK - THICKNESS HDW - HARDWARE TO - TOP OF HM - HOLLOW METAL (STEEL FRAME) TOS - TOP OF SLAB HR - HOUR -ryp - TYPICAL INCL - INCLUDED OR INCLUDING UON - UNLESS OTHERWISE NOTED • INFO - INFORMATION UPS - UNINTERRUPTED POWER SUPPLY INSUL - INSULATION VCT - VINYL COMPOSITION TILE LAV - LAVATORY LF - LINEAR FOOT V i W VE IT R H IFY IN FIELD MATL - MATERIAL MAX - MAXIMUM WC - WATER CLOSET DF wp - WOOD M - MEDIUM DENSITY FIBERBOARD W/0 - WITHOUT 1. PROJECT ADDRESS: AVIATION PARTNERS BOEING RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILA, WA 98168 2. APPLICABLE CODES & ORDINANCES: A BUILDING CODES INTERNATIONAL BUILDING CODE - 2006 B REGULATIONS & ORDINANCES NFPA C ACCESSIBILITY INTERNATIONAL BUILDING CODE - 2006 ICC/ANSI 117.1 ACCESSIBLE & USABLE BUILDINGS AND FACILITIES - 2003 3. GENERAL BUILDING DESCRIPTION: TYPE OF CONSTRUCTION: VB (EXISTING UNLIMITED AREA 507.4) SYSTEM: SPRINKLERED PER NFPA13 QUICK RESPONSE HEADS OCCUPANCY TYPE: 'B' OFFICE 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: EXIT STAIR ENCLOSURES: 1 HOUR CORRIDORS: NON RATED, QUICK RESPONSE SPRINKLER HEADS (1017.1) 5. EXITS: APPROXIMATE AREA OF CONSTRUCTION: 12,500 SQUARE FEET TOTAL APPROXIMATE SUITE AREA: 28,990 SQUARE FEET TOTAL APPROXIMATE FLOOR AREA: 87,500 SQUARE FEET OCCUPANT LOAD FACTOR: 100/SQUARE FE ET NUMBER OF TOTAL PROPOSED OCCUPANTS: 288 IN SUITE NUMBER OF EXITS REQUIRED: 2, 2 PROVIDED MINIMUM EGRESS WIDTH REQUIRED: 3'-8" COMMON PATH OF EGRESS TRAVEL: 100' (1013.3 X 1) 6. PROJECT DESCRIPTION: NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT. NEW PARTITIONS, DOORS, FINISHES. TENANT: GENERAL CONTRACTOR: AVIATION PARTNERS BOEING TBD 7299 PERIMETER ROAD S SEATTLE, WA 98108 PLUMBING ENGINEER: TEL: 206.830.7699 TBD - BIDDER DESIGN BUILD BY G.C. ATTN: DEAN POOR MECHANICAL ENGINEER: ARCHITECT/DESIGNER: TBD - BIDDER DESIGN BUILD BY C.C. BURGESS DESIGN, INC. 1326 - 5TH AVENUE, SUITE 500 ELECTRICAL ENGINEER: SEATTLE, WASHINGTON 98101 TBD - BIDDER DESIGN BUILD BY G.C. TEL: 206.587.7120 FAX: 206.587.7122 FIRE/LIFE SAFETY ENGINEER: ATTN: KIP KOLODZIEJSKI TBD - BIDDER DESIGN BUILD BY G.C. BUILDING MANAGER: SABEY 1 2201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 981 68 PLUMBING, MECHANICAL, ELECTRICAL, TEL: 206.281.8700 LIFE SAFETY PERMITS UNDER SEPARATE FAX: 206.282.9951 SUBMITTALS. ATTN: KARA ANDERSON LEGAL DESCRIPTION / PARCEL NO. PARCEL NUMBER: 0423049190 LEGAL DESCRIPTION: PORTION OF SE 1/4 - BEGIN SW CORNER OF GOV LOT 11 IN SE 1/4 OF SECTION 04-23-04 TH S 89-22-06 E 988.27 FT TH N 14-45-08 W 477.09 FT TO INTERSECTION WITH N LINE OF S 460 FT OF GOV LOT 11 & N ELY MARGIN OF PRIMARY STATE HIGHWAY NO 1 TH N 14-45-08 W 689.81 FT TO SWLY MARGIN OF 200 FOOT SEATTLE TRANSMISSION LINE TH N 14-45-08 W 22.70 FT TAP OF SPIRAL CURVATURE TH CONTINUING ALONG NELY MARGIN ALONG SPIRAL CURVE TO LEFT THE CHORD BEARING N 15-07-51 W 152.94 FT TAP OF SIMPLE CURVATURE TH ALONG NE MARGIN NWLY 340.67 FT ALONG ARC OF NON TANGENT CURVE TO LEFT RADIUS OF 3970 FT RADIUS POINT BEARING S 74-07-22 W THRU C/A OF 04-55-00 TH CONTINUING ALONG SAID NELY MARGIN N 11-24-57 E 327.11 FT TO POINT OF BEGINNING TH N 11-24-57 E 61.40 FT TAP OF SIMPLE CURVE TH CONTINUING ALONG SAID NELY MARGIN NWLY 191.94 FT ALONG ARC OF NON TANGENT CURVE TO LEFT RADIUS OF 4190 FT RADIUS POINT BEARING S 64-42-23 W THRU C/A OF 02-37-29 TH N 27-01-05 E 89.78 FT TH N 48-11-59 E 442.51 FT TH S 41-52-02 E 881.11 FT TH S 48-05-28 W 406.87 FT TH N 41-52-51 W 627.47 FT TH S 48-11-44 W 218.98 FT M/L TO POB - (PORTIONS OF LOTS 1 & 2 OF K C SHORT PLAT NO 588023 RECORDING NO 9006050697 - - LOT 1 OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L96-0002 RECORDING NO 9707090733 STREET MAP DRAWING INDEX \ DRAWING ISSUED , y, if. m.,,As w 1- < cm a) o N N CO a) oo tO N to a) tO v•-• h a) o N N Is. GENERAL pevrnst„,, . - 5 Petri St * X X X G.0.0 COVER SHEET / PROJECT INFORMATION X X X G.0.1 PROJECT NOTES X X G.0.2 SITE PLAN X X X G.0.3 EGRESS PLAN 146rfoli: St - - k tic . 102ruf S s logs_ ' ,,, '040, ARCHITECTURAL / INTERIORS X X A.1.1 DEMOLITION PLAN X X A.2k 1 CONSTRUCTION PLAN x X X X A.2B.1 REFLECTED CEILING PLAN 04t53 ., IN ..105 SV-_Ing ACA ....... X X X A.2C.1 POWER & DATA PLAN X X A.2D.1 FINISH FLOOR PLAN X x X A.9.1 DOOR SCHEDULE / SIDELIGHT SCHEDULE / DETAILS Dm s292th i:-A5- - ssLeisa „ . ......„-, uamish w , = - ,- ..;,Goini, '11,"' III Illa SYMBOLS DEFINITIONS AND DIMENSIONS KEY PLAN FLOOR PLATE , 32 ,, / ,,, A. DEFINITIONS: AVIATION PARTNERS BOEING RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILA, WA 98168 SECOND FLOOR AREA OF WORK 1. iymcm..." OR "TYP" INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. 2. "SIMILAR" OR "SIM." INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 3. "AS REQUIRED" INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS. 4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE, AND PLUMB RELATION ADJACENT MATERIALS. 5 "CLEAR" INDICATES CRITICAL DIMENSION AND SHALL S . ET LAYOUT OF PRECEDENT FOR PARTITIONS. B. DIMENSIONS: ELEVATION REFERENCE SYMBOL 1 i INDICATES FINISHED I SURFACES TO ALIGN DETAIL ID DRAWING TITLE BAR SHEET NO D . SECTION REFERENCE SYMBOL DETAIL IDENTIFICATION DRAWING TITLE GRAPHICAL SCALE A TITLE .3 I SHT FLOOR ELEVATION SYMBOLS ' " 92-0 -Fr-0" NOMINAL FLOOR • iiiiiii m mul Him 11 gill DETAIL REFERENCE SYMBOL DTh BUILDING / ELEVATION HEIGHT (ABOVE/BELOW) SPACE / ROOM ID - - - .--_---. ,-...- , 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING CONSTRUCTION, CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED . 2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING PRIORITY ORDER. A. STRUCTURAL DRAWINGS B. LARGE SCALE DETAILS C. SMALL SCALE DETAILS D. ENLARGED PLANS AND SECTIONS E. FLOOR PLANS 3. MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE REQUIREMENTS SHALL BE MAINTAINED. 4. FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE STRUCTURAL SLAB UNLESS OTHERWISE NOTED. 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR - "AFF". 6. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC CEILING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES, UNLESS OTHERWISE NOTED. 7. DOCUMENTS ARE DRAWN DIAGRAMATICALLY, AND SCALED DIMENSIONS ARE APPROXIMATE. DIMENSIONS SHALL INDICATE REQUIRED SIZE, CLEARANCES, AND RELATIONSHIPS ARE INDICATED BY DIMENSIONS AS NOTED. , el OFFICE -ail-- SPACE NAME , . ill COLUMN AND/OR GRID LINE SYMBOL 1 1127 --- I SPACE NUMBER _ _ III DIMENSION LINE: DOOR SYMBOL flN la • ,:. - .: _ . , . --- -18 , DOCUMENT SHEET SYMBOL L ANGLE © AT g_ CENTERLINE <> ---0--- KEYED SHEET NOTES 0 GLAZING SYMBOL A • . ,.. _ ,..: .., -- ., .:, 1 _ _ _ REVISION NUMBER . 1 fog i ii tr., I . . 1 0 :/ , d1111 _::---, = . -' -, -7 - - ::.:-.. , - , I EXIT EXIT . ,--,- ...........r. MIN INIMIN,JINNIE illIMIII ARM MI Mal- Mg .. - ,,, i.• • EXIT ,_,...., , _ _, _ - ' _ . _. „. - _ -... , - ; 'lip _4 II REVIEWED FOR CODE COIVIPLIANC APPROVED 2009 ,.. , -_ JUL 2 8 A . fjukDwal t_.. BUCIL6tYIN° l ,_......„ 11111111111111 11:11 111111:11 11111111111111 _ 1111111111111i i Ill:1Z% 11111111111111 b 0 9 illIMP I 1 1 A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKINILLA, WA 98168 burgess design J interiors o architecture 1326 Fifth Aveeue Suite 500 . Se . WA 08101 TEL: 206.587.7120 AX:206. 587.7122 M reproduction & intellectual property rights reserved c 2009 Professional seal Flan review approval is subject to errors and °mks Approval of ction • ents does not the violation of any adopted code or ordinance. Receipt of approve4 eld Copy an irs ons is acknowledged By I Data: °Willc):Gf TpurvisPiow No Issue Description REVIEW SET PERMIT SET A REVISION 1 44. REVISION 2 Drawn by: MK/TS Reviewed by: Project No: 09-S804-00 RECEIVED JUL 2 3 21:109 PERMIT CENTER EvISIONS No ch .---", Sh2 .' r to the scope • 1 Of Ttilc Sucrg LIVIS.. NOTE: Revisions will require a new plan submittal / and may include additional plan review fees. SEPARATE PERMIT RE:IRED FOR: 44: FE"Ornbing :VGas Piping City of Tukwila BUILDING DIVISION REGISTERED I ARCHITECT KI LODZIEJSKI STATE OF WASHINGTON Date 6/22/09 6/25/09 07/15/09 07/22/09 KK COVER SHEET / PROJECT INFORMATION Original drawing is 30" x 42". Scale entities accordingly if reduced GOO 08810 - GLASS 1. INCLUDE NECESSARY MATERIALS, LABOR AND ACCESSORIES FOR THE INSTALLATION OF ALL PARTITIONS AS SHOWN . IN THE PLANS. 2. "WALL SURFACES" MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC. 3. ALL PARTITION HEADS SHALL MATCH REQUIRED TO RECEIVE DISABILITIES ACT: VERIFY A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 A PROJECT NOTES 1. THESE PROJECT NOTES ARE GENERIC IN NATURE. CONTRACTORS INSTRUCTIONS FOR CONSTRUCTION ADMINISTRATION MAY VARY BASED ON THE CONTRACT BETWEEN BUILDING MANAGEMENT AND TENANT. VERIFY WITH BUILDING MANAGEMENT ALL CONSTRUCTION REQUIREMENTS AND CONSTRUCTION ADMINISTRATION RESPONSIBILITIES. THE DESIGNER MAY NOT HAVE CONSTRUCTION ADMINISTRATION OBLIGATIONS. 2. PLUMBING, ELECTRICAL, MECHANICAL & LIFE SAFETY SHALL BE PERFORMED UNDER THE DESIGN /BUILD CONTRACT. ALL WORK SHALL BE TO CODE. ANY INFORMATION ON THESE DRAWINGS ARE FOR REFERENCE AND SCHEMATIC DESIGN ONLY. ' CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF THE DESIGN. VERIFY REQUIREMENTS OF BUILDING MANAGEMENT AND TENANT. REVIEW OF SHOP DRAWINGS, IF APPROPRIATE, IS FOR AESTHETIC REASONS ONLY. 3. VERIFY ALL RULES, GENERAL CONDITIONS AND SPECIALIZED BUILDING REQUIREMENTS WITH THE BUILDING MANAGEMENT, 4. ALL WORK BY TENANT SHALL MEET SABEY TENANT CRITERIA MANUAL REQUIREMENTS. DIVISION I - GENERAL CONDTITONS SUMMARY OF WORK 1. GENERAL DESCRIPTION OF THE PROJECT: NON - STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE, LION. 2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CAI I FD OUT AS ''BUILDING STANDARD" ON THE PLANS, THE CONTRACTOR SHALL SO ADVISE BURGESS DESIGN WITHIN TEN (10) DAYS OF THE CONTRACTOR'S RECEIPT OF THE PLANS SO THAT BURGESS DESIGN MAY MAKE ALTERNATE SELECTIONS. UNDER PERMIT BY CONTRACTOR. 6. WORK NOT INCLUDED: CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE SPECIFICATIONS AND SHOWN ON THE PLANS EXCEPT FOR THE ITEMS INDICATED "N.I.C." (NOT IN CONTRACT), SUCH AS TELEPHONE AND DATA CABLES, OFFICE FURNITURE, EQUIPMENT AND MOBILE KITCHEN APPLIANCES. 7. CONTRACTOR TO PROVIDE ALL FIRE /EMERGENCY SYSTEMS AS REQUIRED BY ALL APPUCABLE CODES. FIRE /EMERGENCY SYSTEMS INCLUDE BUT NOT UMITED TO SPRINKLER MODIFICATIONS, FIRE EXTINGUISHERS, AUDIBLE ALARMS, STROBES, SPRINKLERS, SMOKE AND HEAT DETECTORS, AND EXIT SIGNS. 3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES, AND IS RESPONSIBLE FOR ALL ROUGH -IN CONNECTIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. 4. FIRE /EMERGENCY SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, SPRINKLER MODIFICATIONS, FIRE EXTINGUISHER PLACEMENT, AUDIBLE ALARMS, SMOKE AND HEAT DETECTORS, STROBES, AND EXIT SIGN PLACEMENT. 5. ALL DESIGN BUILD INFRASTRUCTURE SHALL BE A SEPARATE 8. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED . AND INDICATED. 9. ANY MATERIAL USED IN CONSTRUCTION SHALL MEET CURRENT FLAME . CODE REGULATIONS. 10. ALL ELECTRICAL, PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHALL COMPLY WITH THE BUILDING SHELL STANDARD SPECIFICATIONS. 11. THE GENERAL CONTRACTOR SHALL LAY OUT THE WORK IN CONFORMITY WITH THE REQUIREMENTS OF CONTRACT DOCUMENTS, AND WILL BE HELD RESPONSIBLE FOR PROPER ESTABUSHMENT AND MAINTENANCE OF ALL ONES AND DIMENSIONS. BEFORE DOING AND WORK, THE GENERAL CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AND CONDITIONS AT THE SITE AND NOTIFY THE ARCHITECTS OF ANY DISCREPANCIES. 12. THE CONTRACTORS SHALL USE DIMENSIONS ONLY. DO NOT SCALE PLANS. ALL DIMENSIONS ARE TO FINISHED FACE UNLESS OTHERWISE NOTED. 13. MATERIALS: ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY MANUFACTURERS. ALL LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURER AND QUALITY UNLESS OTHERWISE SPECIFIED. ALL MATERIAL EQUIPMENT AND FIXTURES SHALL BE CODE WORTHY WITH ALL PROPER JURISDICTIONAL APPROVALS. DIVISION II SrrE WORK 02050 - DEMOLITION 1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ALL ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF ALL DEMOLITION WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN. 2. DEMOLITION OF TELEPHONES, ELECTRICAL, VOICE /DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED CABLING TO BE REMOVED FROM TENANT SPACES BELOW. 3. DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. 4. ALL EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION NEGOTIATED BY THE PRICING PLAN / SPACE PLAN WITH WORK LETTER SHALL BE REMOVED, RELOCATED, OR KEPT FLUSH IN CEILING, WALL, OR FLOOR AS REQUIRED. 5. ALL DAMAGED, ALTERED OR REWORKED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH ". 6. CONTRACTOR SHALL PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUST AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. DMSION VI - ARCHITECTURAL CARPENTRY AND CASEWORK 06100 ROUGH CARPENTRY 1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS, BUCKS, NAILERS, BACKING, FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. AS DETAILED. 06200 - FINISH CARPENTRY 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED. 06400 - ARCHITECTURAL WOODWORK AND CASEWORK 1. CABINET CONSTRUCTION: COMPLY WITH THE A.W.I. ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR CUSTOM GRADE WORK. CABINETS SHALL BE FLUSH CONSTRUCTION. 2. PROVIDE PARTICLE BOARD, MED. DENSITY, WEIGHING <40 LB. /CU. FT., AT LEAST 3/4" THICK. 3. CABINET HARDWARE: FULL EXTENSION DRAWER GLIDES, STAINLESS STEEL CABINET PULLS, US32D FINISH, AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, UON IN ELEVATIONS / DETAILS, OR PER BUILDING STANDARD. 4. PLASTIC LAMINATE: HIGF PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, AND FORMICA, UON. LAMINATE TO BE GENERAL- PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL 5. INTERIOR CABINET SURFACES AND SHELVES TO BE OF PREFINISHED BOARD WITH POLYESTER OVERLAY, UON. 6. SHELF EDGING TO BE VINYL, UON, 7. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. DMSION VIII - DOORS AND WINDOWS 08210 WOOD DOORS 1. PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS. 2. DOOR SCHEDULE SPECIFIES FINISH (BOTH SIDES OF DOOR) AND FRAME, UON. 3. DOORS SHALL BE PRE - MACHINED FOR HARDWARE PER HARDWARE SCHEDULE. 4. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 5. CONTRACTOR SHALL REVIEW SUITE FOR DOOR STYLE CHANGES AND VERIFY WITH ARCHITECT AND BUILDING MANAGEMENT THE DOOR STYLE TO MATCH . IF A VARIATION IS PRESENT. 08710 - FINISH HARDWARE 1. FINISH AND SPECIALTY HARDWARE INCLUDES ALL ACCESSORIES, TOOLS, AND FASTENERS REQUIRED FOR HARDWARE INSTALLATION AND MAINTENANCE. ITEMS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO COMPLETE THE WORK, SHALL BE FURNISHED MATCHING IN QUALITY AND FINISH OF SPECIFIED IN SIMILAR LOCATIONS. 2. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDULE. 3. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE TWO (2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. ALL KEYS TO BE TAGGED WITH ROOM NUMBERS. CONFIRM ' QUANTITY WITH BUILDING MANAGEMENT. 4. SUBMIT HARDWARE SCHEDULE WITH CATALOGUE CUT SHEETS FOR ARCHITECT REVIEW. 5. ALL DOORS SHALL HAVE A MINIMUM OF 1 -1/2 PAIR OF BUTT HINGES, ONE LATCHSET OR LOCK SET, AND ONE DOOR STOP TO MEET ACCESSIBILITY REQUIREMENTS. 6. ALL HARDWARE SHALL BE COMMERCIAL GRADE AND RATED AT REQUIRED ASSEMBLIES. 7. PROVIDE CLOSERS PER HARDWARE SCHEDULE AND AT ALL RATED ASSEMBLIES. 8. ALL HARDWARE SHALL MATCH BUILDING STANDARD IN STYLE AND FINISH. 9. SET UNITS LEVEL, PLUMB AND TRUE TO UNE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND OPERATION. 10. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERY UNIT. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE APPUCATION MADE. 11. PROVIDE PROPER SMOKE GASKETS AT RATED ASSEMBLIES. 12. MATCH BUILDING STANDARD SPECIFICATIONS AND FINISHES. 1. ALL GLASS AT SIDELIGHTS AND DOORS SHALL BE 1/4" TEMPERED SAFETY GLAZING, UON. 2. CONTRACTOR SHALL VERIFY GLASS THICKNESS IS APPROPRIATE FOR DIMENSIONS AND SPANS. 3. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS. GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS. IF GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARD, THEY SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 4. RATED GLASS (CERAMIC) RECITE SHALL BE PREMIUM POLISHED. FINISH. DIVISION IX - FINISHES 09250 GYPSUM DRYWALL AND METAL STUDS BUILDING STANDARD, UON. 4. WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE BUILDING STRUCTURE, UON. 5. SEISMIC BRACING: PROVIDE SEISMIC BRACING AS REQUIRED PER THE LATEST BUILDING CODES TO THE PARTITION HEADS AND, CEILING GRID. 6. FRAMING STUDS: GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE WITH SHEET METAL BACKING WITHIN ALL WALLS RECEMNG CASEWORK (CABINETS, BOOKSHELVES, ETC.). VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCK IF APPLICABLE. 7. CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING, AND ELECTRICAL WORK. FIRE RATE AS REQUIRED. 8. ALL DRYWALL TO BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED. PROVIDE "M /R" TYPE DRYWALL WHERE REQUIRED BY CODE AND AT ALL TOILET ROOMS, AND BEHIND CERAMIC TILES, UON. 9. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS. INSTALL METAL EDGE TRIM WHENEVER EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI - EXPOSED. 10. PRIOR TO RECEIVING FINISH, ALL SURFACES SHALL BE PROPERLY PREPARED AS FINAL FINISHING AS SPECIFIED. 11. EXTEND ALL SOFFIT FRAMING TO STRUCTURE ABOVE. PROVIDE STRUCTURAL DIAGONAL BRACING AS NECESSARY. 12. PROVIDE FRAMING FOR SUSPENDED CEILING WITH SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AND AS SHOWN ON DRAWINGS. 13. USE ACOUSTICAL SEALANT AROUND ALL PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES ETC. ON BOTH SIDES OF CROSSING /PENETRATING WALLS WITH ACOUSTICAL INSULATION. PENETRATIONS OF FIRE -RATED WALLS SHALL BE PROTECTED BY APPLICABLE FIRE -RATED ASSEMBLIES AND MATERIALS. 09500 CEILING SUSPENSION SYSTEMS. 1. PROVIDE NEW CEILING TILE, CEILING GRID AND ALL ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEILINGS AS INDICATED ON DRAWINGS. 2. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. VERIFY WITH BUILDING MANAGEMENT IF EXISTING CONDITIONS ARE SEISMICALLY BRACED OR PROVIDE PER CODE. 3. COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEILING AND THE TELEPHONE AND DATA CABLE COMPANIES WHEREVER THEIR RESPECTIVE WORK IS CONTIGUOUS. 4. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES, REGISTERS, DIFFUSERS, SPRINKLERS, AND OTHER INSERTED ITEMS. 5. ALL CUTOUTS SHALL BE CENTERED WITHIN ACOUSTIC CEILING TILE, UON. 6. ALL MATERIALS SHALL HAVE CLASS 1 FLAME SPREAD RATING AND BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND CODES. 7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL AND PERFECTLY ALIGNED WITH EACH OTHER. 8. INSTALLED SUSPENDED CEILINGS TO BE LEVEL WITHIN A TOLERANCE OF 1/8" IN 12' -0 ". ANCHOR AS REQUIRED. 9. IN AREAS OF ALTERATIONS CONTRACTOR SHALL MATCH CONDITIONS AND MAKE EVERY EFFORT TO ALIGN, LEVEL AND MATCH NEW CEILING TO OLD. CONTRACTOR SHALL REVIEW ALL CEILINGS UPON COMMENCEMENT OF THE PROJECT AND INFORM THE BUILDING MANAGEMENT OF ANY DISCON1TNUfnES IN THE CEILING WITHIN 10 DAYS. 10. ADJUST PARTITION HEAD DETAIL TO MATCH EXISTING CEILING CONDITIONS IF NECESSARY. 09530 ACOUSTICAL TREATMENT 1. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF PARTITION HEAD ABOVE CEILINGS FOR ALL WALLS NOTED PER PLANS. 2. NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND TWO FEET OF INSULATION ON EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID, UON. 09650 - R SILIENT FLOORING 1. PROVIDE VCT, SHEET LINOLEUM, SHEET VINYL AND RUBBER BASE AS INDICATED IN DRAWINGS. COLOR AND MANUFACTURER PER FINISH SCHEDULE. 2. PROVIDE RUBBER - REDUCING STRIPS IN COLOR TO MATCH SPECIFIED BASE. REDUCING STRIPS TO OCCUR AT ALL AREAS OF FLOOR MATERIAL TRANSITION. 3. BASE TO BE INSTALLED IN LONGEST AVAILABLE LENGTH WITH NO PIECE LESS THAN 12 ". NO JOINTS AT OUTSIDE CORNERS OR WITHIN 6" OF CORNERS. 4. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITIOUS UNDERLAY PER MANUFACTURER'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 5. GENERAL CONTRACTOR SHALL APPLY FLOOR WAX TO NEW FLOORING AREAS PER MANUFACTURERS SPECIFICATION, UON. 09680 - CARPET 1. PROVIDE COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS. 2. CARPET TO BE INSTALLED AS INDICATED IN DRAWINGS. 3. PREPARE SUB FLOOR WITH LIGHT WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE. MAX. ALLOWABLE TOLERANCE = 1/4 OVER 10'. 4. PROVIDE SEAMING DIAGRAMS FOR ARCHITECT'S REVIEW. 09900 - PAINTING AND STAIN 1. UNLESS OTHERWISE NOTED, PRIME ALL GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2) FINISH COATS OF BENJAMIN MOORE EGGSHELL FINISH LATEX PAINT OR APPROVED EQUAL, UON. PROVIDE FOR NUMBER OF PAINT COLORS AS INDICATED IN DRAWINGS. 2. FINISH DOORS, DOOR FRAMES, AND SIDELIGHT FRAMES AS INDICATED IN DRAWINGS. A) PAINTED WOODWORK TO BE FINISHED WITH ONE (1) COAT PRIMER AND TWO (2) FINISH . COATS. B) SEALED WOODWORK TO BE STAINED PER FINISH SCHEDULE AND SEALED WITH A COMMERCIAL GRADE CLEAR SATIN VARNISH. 3. PAINT FOR THE LIGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (2 COAT) GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. 4. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (2 COAT) GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES. 5. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM ALL OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME. 6. TOUCH -UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF WORK BY OTHER TRADES. 7. WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY SHALL RECEIVE THE SAME FINISH AS THE ROOM, UON. 8. ALL PAINTED SURFACES SHALL BE PREPARED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (ESPECIALLY IN REGARD TO THE PRIMING OF EXISTING SURFACES). 9. PUTTY ALL NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE APPLYING FINISH. 10. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. 11. SAND ENAMELED FINISHES APPLIED TO WOODS OR METAL BETWEEN COATS WITH FINE SANDPAPER TO PRODUCE SMOOTH FINISH. 12. MAKE FINISH WORK UNIFORM AND SMOOTH, FREE OF RUNS, SAGS, DEFECTIVE BRUSHING AND CLOGGING. MAKE EDGES OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING. DIVISION XII - FURNISHINGS 12500 - WINDOW TREATMENT 1. ALL EXISTING INTERIOR AND PERIMETER MINI BLINDS TO BE BAGGED AND CONDITION. 2. ALL PERIMETER GLAZING TO RECEIVE BLINDS AS INDICATED IN DRAWINGS. MANAGEMENT. MATCH EXISTING CONDITIONS UON. 3. ALL INTERIOR SIDELIGHTS TO RECEIVE 1" MINI -BLINDS WHERE INDICATED IN DRAWINGS. 4. PROVIDE SAMPLE AND CUT SHEET TO ARCHITECT FOR REVIEW. DIVISION XV - MECHANCCAj, CLEANED TO LIKE -NEW COORDINATE WITH BUILDING 15400 - PLUMBING 1. PROVIDE SUPPLY, WASTE AND VENT LINES, VALVES, FITTINGS, ETC. REQUIRED FOR KITCHEN SINKS, DISHWASHER, REFRIGERATOR, AIR CONDITIONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER HEATERS, ETC. 2. ALL FIXTURE INSTALLATIONS SHALL CONFORM TO THE AMERICANS WITH 3. PROVIDE NEW PLUMBING FIXTURES AS SPECIFIED PER DRAWINGS, OR PER BUILDING STANDARD, UON. 4. PROVIDE HOT AND COLD WATER TO SINKS /DISHWASHERS IF APPUCABLE. 5. ALL NEW WATER HEATERS ARE TO BE INSTALLED WITH DRIP PAN CONNECTED TO WASTE UNE. LOCATIONS WITH BUILDING MANAGEMENT AND INSPECTORS. 6. ALL PLUMBING FIXTURES ARE TO BE INSTALLED TO MEET CURRENT GOVERNING LOCAL AND FEDERAL CODES. 7. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 15500 FIRE PROTECTION 1. ALTER OR INSTALL FIRE PROTECTION SYSTEM PER BUILDING STANDARD, LOCAL REGULATIONS AND ORDINANCES. 2. PROVIDE ALL EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS REQUIRED BY CODE. DESIGN AND INSTALL THE SAME IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE SPRINKLERS, FIRE RATED DOORS AND FRAMES, FIRE EXTINGUISHERS, ETC. AS REQUIRED BY APPLICABLE LOCAL CODES AND LAWS. 4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITER'S LABORATORY 2A -1OBC 5 -LB, MULTIPURPOSE EXTINGUISHER WITH SQUEEZE -TYPE HANDLE AND FLEXIBLE DISCHARGE HOSE WITH VISIBLE PRESSURE GAUGE, UON. WALL HYDRANTS CONTRACTOR SHALL VERIFY EXTENT OF 5. FIRE EXTINGUISHERS SHALL BE INSTALLED PER BUILDING STANDARD REQUIREMENTS, UON. VERIFY LOCATION WITH FIRE MARSHALL. 6. DESIGN BUILD FIRE PROTECTION DRAWINGS INDICATE: A. LAYOUT, LOCATION, AND SIZE OF SPRINKLER LINES AND HEADS. B. PRESSURE REQUIREMENTS. C. SPRINKLER HEAD SPECIFICATIONS. D. LOCATION OF FIRE PROTECTION RISERS AND 7. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE HORNS AND STROBES. 8. ALL SPRINKLER HEADS SHALL BE CENTERED IN ACOUSTICAL CEILING TILE, UON 9. USE OF NFPA 13 QUICK RESPONSE HEADS MAY BE REQUIRED. QUICK RESPONSE HEADS BY CITY FOR THIS PROJECT. 15600 HEATING VENTILATING AND AIR CONDITIONING 1. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH ALL MATERIALS, LABOR AND ACCESSORIES FOR COMPLETE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE HVAC SYSTEM AS REQUIRED. 2. DESIGN BUILD MECHANICAL ENGINEERING DRAWINGS INDICATE: A. DUCTS, AIR MOVEMENT REQUIREMENTS, & SIZES OF GRILLES & REGISTERS. 3. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 4. HVAC CONTRACTOR TO CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS, FILTERS AND THERMOSTATS. 5. RE -ZONE, ALTER OR SEPARATE HVAC AS NECESSARY AS DIRECTED BY BUILDING MANAGEMENT FOR ALTERED SUITES. 16000 - ELECTRICAL AND TELECOMMUNICATIONS 1. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. REPLACE OUTLET COVER PLATES TO MATCH NEW FINISH IF APPLICABLE. 2. PROVIDE ALL WORK, EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL SYSTEM. PROVIDE ELECTRICAL OUTLETS PER POWER AND DATA PLAN. 3. PROVIDE MUD RING FOR DATA AND COMMUNICATION AS SHOWN ON THE POWER AND DATA PLAN. EACH MUD RING TO HAVE A MINIMUM NUMBER OF WIRE PULLS AS INDICATED ON DRAWINGS. COORDINATE DATA CABLE CONFIGURATION WITH THE TENANT. 4. ALL OUTLETS AND MUD RINGS TO BE LOCATED AT 18" AFF TO THE CENTER LINE, UON. 5. WHERE MULTIPLE DEVISES OCCUR IN A SINGLE LOCATION, ALL DEVICES SHALL BE GANGED UON. 6. ALL ELECTRICAL OUTLETS WITHIN THE CODE REQUIRED DISTANCE FROM A SINK SHALL BE ON A GROUND FAULT INTERRUPTED CIRCUIT. 7. ALL WIRING DEVICES: SHALL BE BUILDING STANDARD EXCEPT: "ISOLATED GROUND" OUTLETS SHALL BE ORANGE, "HOSPITAL GRADE ISOLATED GROUND" OUTLETS SHALL BE ORANGE WITH A GREEN DOT, "EMERGENCY" OUTLETS SHALL BE RED, AND "DEDICATED" OUTLETS FOR "CLEAN CIRCUIT" FIXTURES SHALL BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). ALL COVER PLATES SHALL BE BUILDING STANDARD FINISH, UON. VERIFY WITH BUILDING MANAGEMENT. 8. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING THE COMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION DOCUMENTS. TELEPHONE SWITCH, COPIERS, 9. COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE INSTALLATION OF TENANT'S NEW FURNITURE. 10. ALL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING, AND CONDUIT SHALL BE CONCEALED IN FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA TO BE PROVIDED BY TENANT'S VENDORS AND SHALL BE COORDINATED BY THE BUILDING MANAGER. 11 THE CONTRACTOR IS TO COORDINATE WITH THE OWNER SUPPLIED FURNITURE SYSTEMS TO INCLUDE BUT NOT LIMITED TO: ELECTRICAL AND DATA WIRING LOCATIONS, J -BOX LOCATIONS, CONNECTIONS AND WALL MOUNTED REQUIREMENTS. 12. THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH MATERIAL TO MEET FLAME SPREAD REGULATIONS. LOCATIONS TO BE PREPARED TO RECEIVE NEW FLOOR FINISH AS REQUIRED. FLOOR SHALL BE LEFT FLUSH. 13. ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY OF DEVICES SHOWN. SWITCHING AND CIRCUITING SHALL BE INDICATED ON SEPARATE ELECTRICAL ENGINEERING AS- BUILT DRAWINGS AND SHALL MEET OWNER'S GUIDELINES. 14. ALL TELEPHONE, ELECTRICAL, COMMUNICATION AND SECURITY WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE CODES. 15. DRAWINGS INDICATE ALL DIMENSIONS TO CENTERLINE OF TELEPHONE, ELECTRICAL, AND COMMUNICATION COVER PLATE. OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION BETWEEN EACH DEVICE. 16. BACK -TO -BACK OUTLETS ARE NOT PERMITTED. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED FOR ACOUSTICAL CONTROL 17. LOCATION OF ALL WALL MOUNTED POWER AND DATA DEVICES SHALL BE FIELD REVIEWED BY THE TENANT BEFORE INSTALLATION. 18. ELECTRICAL ENGINEER TO PROVIDE DESIGN /BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. 19. THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER & DATA DEVICES. REFER TO DESIGN /BUILD DOCUMENTS FOR SCOPE, TECHNICAL LAYOUT AND SPECIFICATIONS FOR EACH DISCIPLINE. 20. ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES. COORDINATE EXACT LOCATION WITH FURNITURE VENDOR. 21. COORDINATE POWER /DATA, FIRE SAFETY DEVICES & UGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR ELEVATIONS, SYSTEM FURNITURE, FINISHES & CASEWORK. 22. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER /DATA DEVICES AND LIGHT FIXTURES.' COORDINATE WITH INTERIOR FINISHES AND CASEWORK. 23. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE GRILLS AND THERMOSTATS. 24. RECIRCUIT, ALTER OR SEPARATE ELECTRICAL AND VOICE SYSTEM AS NECESSARY AND AS DIRECTED BY BUILDING MANAGEMENT FOR ALTERED SUITES. 16500 - LIGHTING 1. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED CEILING PLAN. ALL SWITCHES SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 48" A.F.F. TO MEET THE LATEST ACCESSIBILITY CODES AND REGULATIONS. 2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION, ALL SWITCHES SHALL BE GANGED UON. 3. DOWN LIGHTS SHOWN IN THE CENTER OF CEILING TILE WITHOUT DIMENSIONS ARE TO BE LOCATED IN THE CENTER OF CEILING TILE, UON. 4. REUSE ALL EXISTING BUILDING STANDARD FLUORESCENT FIXTURES AS NEEDED PER DESIGN LAYOUT AND TO MEET LOCAL ENERGY CODE COMPLIANCE. VERIFY OR PROVIDE ` NEW LAMPS AND REPLACE FAULTY BALLASTS. 5. PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD PRIOR TO COMMENCEMENT OF WORK. 6. ALL OFFICE AREAS LESS THAN 300 SQ. FT. ENCLOSED BY WALLS OR CEILING- HEIGHT PARTITIONS, AND ALL MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS, PER CODE. 7. DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS INDICATE: A. CIRCUITING AND WIRING OF LIGHT FIXTURES, AND SWITCHES. B. LIFE SAFETY EQUIPMENT. C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES. D. LIGHT FIXTURE SPECIFICATIONS 8. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS. TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 9. CONTRACTOR SHALL RE- CIRCUIT AND RE- SWITCH ALL ASPECTS OF TENANT SUITE AND ADJOINING SUITES AS NECESSARY TO FULLY SEPARATE TENANT SUITE FROM OTHERS, AND PROVIDE NEW CORRIDOR, HALLWAY AND OPEN OFFICE SWITCHES AS NEEDED. 10. VERIFY SWITCHING WITH TENANT AND BUILDING MANAGEMENT. VERIFY APPROVED ENERGY CODE REQUIREMENTS OR ENERGY MANAGEMENT SYSTEM AS PART OF THE DESIGN BUILD CONTRACT. 11. PROVIDE, ALTER OR VERIFY ALL EMERGENCY EXIT LIGHTING AND ACCESS PATHWAY LIGHTING AS DIRECTED BY EXISTING CONDITIONS AND CODE REQUIREMENT& burgess design I interiors 0 architecture 1376 Fifth Avenue Suite 500. Se title . WA 98101 TEU 206.587.7170 FAX:206. 587.7122 All reproduction & intellectual property rights reserved c 2009 Professional seal No. issue Description REVIEW SET PERMIT SET REVISION 1 REVISION 2 Drawn by: MK /TS 7196 Project No: 09- S804 -00 gVED 3 2009 tllNiIf GEWER Reviewed by: PROJECT NOTES REGISTERED ARCHITECT KIP G. KOLODZiEJSKI STATE OF WASHINGTON REVIEWED FOR CODE COMPLIANCE PPROVED JUL 2 8 2009 City of Tukwila BUILDING DIVISION Original drawing is 30" x 42 ". Scale entities occordingly if reduced G.0.1 Date 6/22/09 6/25/09 07/15/09 07/22/09 KK SITE PLAN NOT A LEGAL SURVEY FUTURE NORTHWIND WEIR PARK. BOEI \ G ACC A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 burgess design J interiors Q architecture 1025 Fifth Avenue Suite 500.5e2ttle: WA 08101 TEL: 208.587.7120 FAX:206.587.7122 All reproduction & intellectual property rights reserved c 2009 Professional seal No. issue Description REVIEW SET PERMIT , SET REVISION 1 REVISION 2 Project No: 09— SB04 -00 SITE PLAN 7196 KIP G. KOLODZ!FJSK STATE OF WASHINGTON Date 6/22/09 6/25/09 07/15/09 07/22/09 Reviewed by: KK REVIEWED FOR CODE COMPLIANCE APPROVED JUL 282009 City of Tukwila BUILDING DIVISION Original drawing is 30" x 42". Scale entities accordingly if reduced, LONGEST COMMON PATH OF EGRESS TRAVEL: 54'-11" A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET, TUKWILLA, WA 98168 burgess design I interiors Q architecture 1326 Fifth Avenue Suite S0O. Settle . WA 88101 fEt: 206.587.7170 FAX:206. 587,7122 All reproduction & intellectual property rights reserved c 2009 K!? G. KOLODZIEJSi:I STATE OF WASHINGTON SYMBOL LEGEND — — — EGRESS PATHWAY FOR EMERGENCY LIGHTS. DESIGN BUILD CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTS, PER 1006. VERIFY PATHWAY WITH FINAL FURNITURE LAYOUT. 1. THIS TENANT IMPROVEMENT TO BE PERMITTED AS MIXED OCCUPANTS WITH UNSEPARATED USES PER IBC SECTION 302.1 THE ORIGINAL BUILDING WAS PERMITTED WAS A V —N FIRE SPRINKLERED BUILDING IN 1987 WITH UNLIMITED AREA WITH 60' YARDS ON ALL SIDES. WE PROPOSE TO CHANGE THE BUILDING CLASSIFICATION, BASED ON 2003 UBC, TO CONSTRUCTION TYPE VB FIRE SPRINKLER WITH UNUMITED AREA PER SECTION 507.3 "TWO STORY." THE AREAS OF A TWO STORY GROUP B, F, M OR S BUILDING SHALL NOT BE LIMITED WHEN THE BUILDING IS PROVIDED WITH AN AUTOMATIC SPRINKLERS SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 THROUGHOUT AND IS SURROUNDED AND ADJOINED BY PUBLIC WAYS OR YARDS NOT LESS THEN 60 FEET IN WIDTH. EXITS ARE GREATER THAN 1/3 DISTANCE OF DIAGONAL (1015.2.1 X 2) 0`1411 III Drawn by: MK /TS Reviewed by: Project No: 09— SB04 -00 EGRESS PLAN RECEN JUL 2 3 2009 PERMIT CENTER KK REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 8 2009 City of Tukwila BUILDING DIVISION Original drawing is 30" x 42 ". Scale entities accordingly if reduced G.0.3 A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 burgess design J interiors Q architecture 1126 Fifth Avenue Suite 500. Seattle. WA 08101 TEL: 206.587.7420 FAX:206. 587.7722 All reproduction & intellectual property rights reserved c 2009 KIP G. KCLCDZI_JSK! STATE OF WASHINGTON DEMOLITION PLAN AI DEMOLITION SYMBOLS EXISTING CONSTRUCTION TO BE REMOVED EXISTING CONSTRUCTION TO REMAIN GENERAL DEMOLITION NOTES 1. REFER TO CONSTRUCTION PLAN, CEILING PLAN, ELECTRICAL PLAN AND FINISH PLAN FOR EXTENT OF DEMOLITION. 2. SAVE AND STORE ALL LIGHT FIXTURES, EXIT SIGNS, DOORS & HARDWARE FOR RE -USE, UON. 3 . SAVE ALL EXISTING PLUMBING FIXTURES FOR RE —USE, UNLESS OTHERWISE NOTED. 4 . REMOVE ALL TELEPHONE, ELECTRICAL, AND DATA OUTLETS, FIXTURES, PANELS, ETC FROM ALL DEMOLISHED PARTITIONS. REMOVE ALL CORRESPONDING CABLES, CONDUIT, WIRING, ETC. All THE WAY BACK TO THE ORIGINATING SOURCE, UON. KEYED SHEET NOTES DEMO DOOR, FRAME, AND HARDWARE — TO BE STORED OR RELOCATED AND REINSTALLED WHERE APPLICABLE. VERIFY WITH BUILDING ` MANAGEMENT. DEMO RELTTE AND FRAME— TO BE STORED OR RELOCATED AND REINSTALLED WHERE APPLICABLE: VERIFY WITH BUILDING MANAGEMENT. DEMO EXISTING WALL PANELS TO BE REMOVED. PATCH AND REPAIR WALL AS REQUIRED FOR INSTALLATION OF NEW WALL PANELS. O 4 REMOVE EXISTING FULL HEIGHT WHITE BOARDS. PATCH AND REPAIR WALL AS REQUIRED FOR NEW FINISHES. DEMO EXISTING COUNTERTOP. COORDINATE STORAGE AND REINSTALLATION, IF APPLICABLE, WITH BUILDING MANAGEMENT. PATCH AND REPAIR WALL AS REQUIRED FOR NEW FINISHES. 6 O DEMO EXISTING BASE AND UPPER CASEWORK WHERE APPLICABLE. TO BE STORED AND REINSTALLED WHERE APPLICABLE, VERIFY WITH BUILDING MANAGEMENT. PATCH AND REPAIR WALL AS REQUIRED FOR NEW FINISH. 7O DEMO EXISTING PASSTHRU DOORS AND FRAME. PATCH AND REPAIR WALL AS REQUIRED FOR NEW FINISH. 4 :: REMOVE AND RELOCATE EXISTING FIRE EXTINGUISHER. O DEMO EXISTING COMPUTER /SERVER RACKING. VERIFY EXTENT OF REMOVAL OF ASSOCIATED WIRING AND HARDWARE WITH TENANT AND BUILDING MANAGEMENT. PATCH AND REPAIR FLOORING AS REQUIRED AFTER REMOVAL SEE KEYNOTES ON A.2C.1 FOR MORE INFORMATION. 0 ABANDON EXISTING CORE DRILLS. <> CONTRACTOR SHALL CAREFULLY MEASURE EXISTING DECORATIIVE WOOD PANELS BEFORE DEMOLITION. CONSTRUCTION OF NEW PANEL WILL MATCH THESE EXISTING PANELS. I t REVISION 1 6/25/09 07/15/09 07/22/09 REVISION 2 9 Drawn by: MK /T Reviewed by: Project No: 09- SBO4 -0O DEMOLITION PLAN RECEIVED JUL 23 2009 PERMIT CENTER KK REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 8 2009 Original drawing is 30" x 42 ". Scale entities accordingly if reduced City of Tukwila BUILDING DIVISION A.1.1 NEW OFFICE NEW CONFERENCE NEW OFFICE 11111111111111 11111111111111 11111111111111 OPEN OFFICE 1 231A NEW CONFERENCE NEW CONFERENCE NEW OPEN OFFICE CLOSET A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD, SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 burgess design I interiors >rvj architecture i326 Mil Avenue Suite 500 . Seattie . WA 98101 TEE: 208.587.7120 FAX:206. 587.7122 All reproduction & intellectual property rights reserved c 2009 KIP G. KOLODZIEJSKI STATE OF WASHINGTON CONSTRUCTION PLAN 16' 24' SYMBOL LEGEND Offissississial iiii���iZeM F.E. EXISTING CONSTRUCTION TO REMAIN NEW INSULATED INTERIOR PARTITON CONSTRUCTION, PER DETAIL S /A.9.1 FULL HEIGHT SIDELITE PARTIAL HEIGHT SIDELITE u I- FRAMELESS SIDEUTE NEW CASEWORK / MILLWORK LINE OF UPPER CABINETS NEW OR RELOCATED FIRE EXTINGUISHER CABINET AND DEVICE 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. GENERAL CONTRACTOR TO FIELD VERIFY Al EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. ALL INTERIOR PARTION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PAR1111ON RATINGS. 4. WHERE PARTITION LAYOUT INTERSECTS EXISTING SHELL/CORE GYPSUM BOARD, REMOVE EXISTING CORNER BEADS AND OTHER ACCESSORIES, ALIGN FACE OF PARTMONS, TAPE & SAND SMOOTH FOR NEW FINISH. 5. PROVIDE PARTITION ANCHOR BRACKETS FOR ALL CASEWORK, FIXTURES, EQUIPMENT, & DEVICES MOUNTED ON OR ATTACHED TO PARTTTIONS. i. PARTITIONS ARE TO BE BUILDING STANDARD FLOOR TO CEILING PARTITIONS, VON. SEE TYPICAL WALL DETAIL SHEET FOR MORE INFORMATION. DOORS AND CASED OPENINGS WITHOUT DIMENSIONS OR DETAILS ARE TO BE LOCATED 4" FROM ADJACENT WALL OR MATCH EXISTING SUITE STANDARD. ALL TENANT SIGNAGE BY TENANT. • GENERAL CONTRACTOR SHALL PROVIDE BLOCING FOR A/V SCREENS AS REQUIRED ON ALL NEW WALLS. SEE TENANT'S A/V VENDER FOR LOCATIONS. ON EXISTING WALLS, VERIFY BLOCKING NEEDED WITH A/V VENDER. GENERAL CONTRACTOR TO PROVIDE BRACKETS. KEYED SHEET NOTES O MODIFY CASEWORK AS REQUIRED FOR (2) NEW DISHWASHERS AND PROVIDE FINISHED END PANELS TO MATCH EXISTING P -LAM. DRAINAGE ONES CAN BE SURFACE MOUNTED TO PARTITON AND PAINTED. 2O REPLACE EXISTING RELITE AND TRANSOM GLASS WITH NEW INSULATED GLASS WITH 3M FILM. O3 PROVIDE NEW CHERRY WOOD VENEER PANELS IN PLACE OF EXISTING DECORATIVE PANELS ON THIS WALL 4:::: ACOUSTICAL BATT INSULATION FULL HEIGHT. PROVIDE ACOUSTICAL SEALANT B0TH SIDES OF WALL AT BASE. PROVIDE ACOUSTICAL TAPE AT WALL HEAD. 4:: PROVIDE A 28" DEEP PL — WORK SURFACE AT 29" A.F.F. WITH SUPPORTS A MINIMUM OF EVERY 24 ". SEE DETAIL F /A.9.1 FOR MORE INFORMATION. • PROVIDE A 18" DEEP FL COUNTER AT 42" A.F.F. WITH SUPPORTS A MINIMUM OF EVERY 24 ". SEE DETAIL F /A.9.1 FOR MORE INFORMATION. PROVIDE (2) 8' WIDE WHITE BOARDS. VERIFY LOCATION WITH TENANT. VERIFY LENGTH OF NICHE WITH BOOKCASE IS CURVED AND 6' -0' LONG PROVIDE 3M FILM ON DOORS AND VISION PANELS. FINAL FILE CABINET FURNITURE PURCHASE. NEW WD -1 BOOKCASE TO RUN ALONG BACK OF RECEPTION AREA. AND (2) SHELVES HIGH. TOP ALIGNS WITH EXISTING. 11 CONTRACTOR SHALL CUT CEILING AND PROVIDE EXTENSION OF PARTITON UP TO STRUCTURE ABOVE. NEW CAVI1Y AND VERIFY OR PROVIDE INSULATION AT EXISTING PARTITION. INSULATE • DEAD SPACE. VERIFY NOTHING NEEDING ACCESS IS IN THIS SPACE, MOVE OR ABANDON AS NECESSARY. 14 i5 • PROVIDE INSULATION IN PARTITIONS AND ABOVE PARTITIONS IN THIS OFFICE INSULATE THIS PARTITION. PROVIDE NEW 24" DEEP PL WORK SURFACE WITH SUPPORTS AT A MINIMUM OF EVERY 24 ". SEE DETAIL F /A.9.1. PROVIDE NEW CASEWORK, TOPS AND VERTICAL SURFACES IN WD -1 FINISH. MATCH STYLE OF CABINETS NEAR BY. INSIDE TO BE FINISHED WITH GREY PLASTIC LAMINATE. VERIFY SIZE OF UNDER COUNTER REFRIGERATOR WITH FINAL APPLIANCE PURCHASE. 17 RELOCATED DOOR AND SIDEUGI-ITE ASSEMBLY. M/S Pr awn No by O9— K TS804 -00 Reviewed by: REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 8 2009 ?ECEIVED JUL 2 3 2009 PERMIT CENTER City of Tukwila BUILDING DIVISION Original drawing is 30" x 42 ". Scale entities accordingly if reduce A.2A. 1 WALL MOUNTED DEVICES M NOTATION KEYED SHEET NOTES EQUIPMENT LIST - VERIFY ALL REQUIREMENTS WRH TENANT SYMBOL DESCRIPTION GFI DENOTES A GROUND FAULT INTERRUPT CIRCUIT O SERVER ROOM: COORDINATE POWER, COMMUNICATION, AND BTU OUTPUT WITH TENANT. TENANT IS RESPONSIBLE TO MAINTAIN ALL LANDLORD SUPPLIED APPLIANCES. REFRIGERATOR (BY TENANT, G.C. TO PROVIDE COPPER WATER LINE AND HOOK UP ICE MAKER AS REVD) 4 TOTAL COFFEE MAKER (BY TENANT, G.C. TO PROVIDE COPPER WATER UNE) 2 TOTAL DISHWASHER (BY G.C. - BUILDING STANDARD 4 -CYCLE RESIDENTIAL GRADE, VERIFY ADA COMPLIANCE, COLOR PER TENANT) 2 TOTAL UNDER COUNTER REFRIGERATOR (BY TENANT) 1 TOTAL HOT WATER HEATER BY G.C. - COORDINATE LOCATION WITH ( BUILDING MANAGEMENT AND CODE COMPLIANCE) NEW GARBAGE DISPOSAL (BY G.C.) 1 TOTAL f Y `:7 7_° EXISTING TO REMAIN (VOICE /DATA OUTLETS NOT CONFIRMED FOR CAPACITY) T DENOTES TIMER 2O EXISTING ELECTRICAL IN THIS ROOM TO REMAIN. 4:: . CONTRACTOR TO ALTER EXISTING ANGLE STOPS TO PROVIDE WATER LINES FOR REFRIGERATORS. 4 WATER HOOK-UPS AND TIMERS FOR COFFEE MAKERS ARE TO BE NEW CONTRACTOR TO VERIFY IF THERE ARE EXISTING HOOK -UPS PROVIDED. IF EXISTING, THEY MAY BE USED IF THEY ARE WITHIN 18" a. i 5 NOT USED. O 0 AREA OF COAXIAL CABLE DISTRIBUTION. 1 C (� DUPLEX OUTLET ( # DENOTES MOUNTING HT IN INCHES) GENE 1 \ A L S 1 1 E E T N OT E S 3 -�;3 QUADRAPLIX OUTLET 1.. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2 . ELECTRICAL SUB- CONTRAC TOR IS RESPONSIBLE FOR VERIFYING THE WORKING CONDmON OF ALL EXISTING OUTLETS NOTED TO REMAIN. , 3. ALL OUTLETS SHOWN ARE APPROXIMATE. DUE TO HIDDEN CONDITIONS ADDmONAL P /P /D MAY EXIST BUT NOT BE REFLECTED ON :THE PLANS. 4. FURNITURE SHOWN FOR INTENT ONLY, FINAL LOCATION OF FURNITURE AND OUTLETS TO BE COORDINATED WITH TENANTS FURNITURE VENDOR. VERIFY ELECTRICAL AND VOICE /DATA REQUIREMENTS WITH TENANT. 5 ALL DATA, TELEPHONE, WIRING AND SECURITY BY TENANT. 6. ALL CONFERENCE ROOM MEDIA EQUIPMENT FURNISHED AND INSTALLED BY TENANT, INCLUDING ALL POWER, DATA AND VIDEO. 7. MODIFY CEILING ELECTRICAL J -BOXES FOR NEW POWER POLES. $. SCHEMATIC ELECTRICAL AND VOICE /DATA DESIGN CAN REUSE EXISTING IF SHOWN WITHIN 18 * EXISTING LOCATION. 9. TENANT'S FURNITURE CONNECTED BY TENANT'S ELECTRICIAN. 10. DESIGN BUILD ELECTRICIAN SHALL VERIFY EMERGENCY PATHWAY WITH FINAL FURNITURE LAYOUT. 11. ALL FURNITURE AND WIRING TO SYSTEMS FURNITURE SUPPUED BY TENANT. 12. Al AV EQUIPMENT AND WIRING SUPPLIED BY TENANT. 4 � DEDICATED DUPLEX OUTLET 5 6 .� 7 PROVIDE WATER LEAK SENSOR AT WET AREAS. O 8 EXISTING RACK TO REMAIN FOR VOICE EQUIPMENT IN LIEU OF PHONE BOARD. O g VERIFY MOUNTING LOCATIONS WITH TENANT'S A/V DRAWINGS. O O 10 DRAWINGS SHOW A/V REQUIREMENTS AT SYSTEMS FURNITURE. TENANT PREFER OUTLETS GO TO THIS LOCATION. GENERAL CONTRACTOR WILL VERIFY POWER REQUIREMENTS AND OUTLET LOCATIONS WITH Q TENANT. O 11 VERIFY LOCATION WITH TENANT'S FURNITURE. DEDICATED ® EDICATED OUTLETS FOR SECURITY PANELS. VERIFY LOCATION WITH TENANT VENDOR. 13 O NOT USED. INSTALL TENANT PROVIDED SMART INTERACTIVE WHITE BOARD SYSTEM. VERIFY LOCATION OF POWER AND 14 VOICE DATA WITH TENANT'S A/V VENDOR. Nz I JUNCTION BOX 7 PLOTTER BY TENANT (BY TENANT) 1 TOTAL 2 X CAT6 DATA WITH RJ45 "CONNECTIONS GENERAL SHEET NOTES 1 X 6 DATA CAI' A A WITH RJ45 CONNECTIONS CONTRACTOR SHALL PROVIDE (2) COAXIAL CABLES FROM ROOF TOP DISH TO LOCATION IN SERVER ROOM. DISH INSTALLATION IS NON- PENETRATING. 1 X CAT6 VOICE WITH RJ11 CONNECTIONS POWER POLE - VERIFY SYSTEMS FURNITURE REQUIREMENTS FOR POWER Q AND VOICE /DATA W/ TENANT. P OWER WHIP - VERIFY SYSTEMS FURNITURE REQUIREMENTS FOR POWER AND VOICE /DATA W/ TENANT. NEW CARD READER (G.C. TO PROVIDE REQUIRED POWER) CR I © COAX CABLE TV OUTLET NEW CONFERENCE Oil — % % / Y r / / / / / / / / % J - J J J J J J J 4. w E 2' A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 burgess design I interiors Q architecture 1926 fifth Avenue Suite SOO. Se tUe . WA 08101 TEL: 206 587.7120 5AX:206. 587.7122 All reproduction & intellectual property rights reserved c 2009 KIP G. KOLODZIEJSKI STATE OF WASHINGTON POWER AND DATA PLAN 0 8' 16' 24' 1/8" = 1'- 0" REVISION 1 REVISION 2 Drawn by: MK /TS Rev iewed by: Project No 09— S804 -00 POWER AND DA PLAN RECEIVED JUL 23 2009 PERMIT CENTEF 07/15/09 07/22/09. KK REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 8 2009 Original drawing is 30" x 42 ". Scale entities accordingly if reduced A.2C.1 City of Tukwila BUILDING DIVISION OFFICE 25 ;.•:..ter : - _.. 1111111111111 ' i A , j /���j��j 7, A A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILA, WA 98168 . burgess design interiors 0 architecture 1776 Fifth Avenue Suite 500. Solite . WA 98101 TEE: 206.587.7120 FAX:706. 587.7122 All reproduction & intellectual property rights reserved c 2009 KIP G. KOLODZIEJSKI STATE OF WASHINGTON qi 1 /8" = 1'- • FINISH SPECIFICATIONS SYMBOL I B-1 MANUFACTURER ROPPE DESCRIPTION BASE 4 "h COVED RUBBER BASE. COLOR: TBD CARPET I CPI' -1 I FIELD CARPET COLOR: TBD INSTALLED: DIRECT GLUE PL -2 I TBD PLASTIC LAMINATE VERTICAL SURFACES LAMINATE COLOR: — INTERIOR MELAMINE COLOR DARK CHERRY STYLE MATCH DESIGNERS SAMPLE PAINT I P -1 I I P -2 P -3 I BENJAMIN MOORE BENJAMIN MOORE BENJAMIN MOORE GWB EGGSHELL FINISH COLOR: - GWB EGGSHELL FINISH COLOR: — WOOD DOOR /FRAME SATIN LATEX FINISH COLOR: — I P-4 VCT TBD ELECTROSTATIC PAINT COLOR: — /OW In. ..ION. I ...a11111•. ..•11111. /Ilan . r r ■ _- ■■ r i : � .Ire � ..AIM. r\ I CPT2 I TBD PLASTIC LAMINATE TBD EXECUTIVE AREA CARPET COLOR: TBD INSTALLED: OVER PAD PLASTIC LAMINATE HORIZONTAL SURFACES /BACKSPASH. LAMINATE COLOR: — INTERIOR MELAMINE COLOR GENERAL FINISH NOTES 1. PROVIDE B -1 THROUGHOUT, UON. 2. PROVIDE P -1 THROUGHOUT, UON. 3. PROVIDE CPT-1 THROUGHOUT, UON. 4. REFER TO ELEVATIONS AND DETAIL SHEETS. 5. CENTER TRANSMON BETWEEN MATERIALS UNDER DOOR PER DETAILS. 6• ALL EXISTING DOORS TO BE PAINTED TO MATCH NEW DOORS. 7. FOR BUILDING PURPOSES USE 30oz CARPET. 8: CLEAN ALL WINDOW BLINDS ON JOB SITE. 9. ALL NEW CASEWORK ID FOUND ON A.2A.1. REFINISHED CASEWORK IS FOUND ON A.2D.1. KEYED SHEET NOTES > FLOORING IN THIS ROOM IS EXISTING TO REMAIN. 24 REFINISH EXISTING WOOD RECEPTION DESK TO WD -1 FINISH. 3O PROVIDE NEW WD -1 TOPS ON EXISTING CASEWORK. PROVIDE A COST OPTION TO REPLACE CASEWORK WTTH NEW WD -1 EXTERIORS AND GREY PLASTIC LAMINATE INTERIORS. O ELECTROSTATICALLY PAINT WOMEN'S RESTROOM PARTITIONS WTTH P O PROVIDE NEW WALL PANELS TO MATCH EXISTING AND DEMO'D WALL PANELS. PANELS FINISHED IN WD -1. O REMOVE EXISTING CARPET AND PROVIDE NEW VCT -1. MATCH EXISTING TO MATCH EXISTING VCT. PROVIDE STATIC CONTROL WAX COATING. REVISION 1 07/15/09 07/22/09 REVISION 2 Reviewed by: KK FINISH FLOOR PLAN REVIEWED FOR CODE COMPLIANCE APPF OV D • re•uce• RECEIVED JUL 23 2009 PERMIT CENTER Original drawing is 30" x 42 ". Scale entities a A.2DA JUL 2 8 2009 City of Tukwila BUILDING DIVISION HARDWARE GROUP GROUP 1 DUSTING HARDWARE GROUP 2 PAIRED, GLASS DOOR HARDWARE NON-RATED GROUP 3 SINGLE, ENTRY LOCKSET NON-RATED GROUP 4 SINGLE PASSAGE IATCHSET NON-RATED GROUP 5 SINGLE OFFICE LOCKSET NON-RATED GROUP 6 SINGLE, STOREROOM LOCKSET NON-RATED HARDWARE 2 DEAD BOLT LOCKSET AT BOTTOM RAIL 2 PAIR PIVOT HINGES 2 B/S a D* PULLS EACH SIDE 2 AUTOMATIC FLUSH BOLT 2 DUST PROOF STRIKE 2 DOOR CLOSERS - INTEGRATE INTO HINGES 2 WALL-MOUNTED DOOR STOPS 1 CARD READER 1 MAG LOCK, MUST COMPLY WI IBC 1008.1.3.4 1 PASSAGE LATCHSET 1.5 PAIR HINGES 1 WALL-MOUNTED DOOR STOP 1 OFFICE FUNCTION LOCKSET 1.5 PAIR HINGES 1 WALL-MOUNTED DOOR STOP 1 STOREROOM FUNCTION LOCKSET 1.5 PAIR HINGES 1 WALL-MOUNTED DOOR STOP CONNECTED TO TENANTS CARD READER SYSTEM 1 ENTRY FUNCTION LOCKSET 1.5 PAIR HINGES 1 DOOR CLOSER 1 FLOOR-MOUNTED DOOR STOPS 1 ELECTRIC STRIKE, MUST COMPLY W/ IBC 1008.1.3.4 CONNECTED TO TENANTS CARD READER SYSTEM 202 3 203 3 204 3 205 3 206 3 207 3 208 3 209 E AWN. ■MM■ , NR! 'am 'mum" "IN/ . 'um" 'MI"' 'MM 'OP ' 'MM 'Mi.' 'UM' ..11111./ 'UMW NMI./ 249B 250A 250B 251 E E E E E E 3 7 B 252 3 7 B /Mo. ■11111■ /1111■■■■ AM■AM■IIII■■■■■■•■■■■•■ AWN, /111■ /NW. AMR. RACING WIRE A RACING VARIES (SEE PLAN) TO BE HEAVY DUTY, PER ASCE 7-02 ITEM 9.6.2.6.2.2a. BACKSPLASH (WHERE OCCURS) SCRIBE TO WALL COUNTER TOP FOR FINISHES SEE A.2A.1 AND A.2D.1. SUPPORT BRACKET @ 24" O.C. MAX. P-LAM LEDGER FINISH FLOOR LINE SEISMIC COMPRESSION STRUT 2 GA. VERTICAL HANGER WIRE AT 4 EACH WAY WITH MINIMUM 3 TIGHT TURNS IN 1 1/2* BOTH ENDS OF WIRE ARE TO BE THREE TIGHT TURNS AROUND ITSELF WITHIN THREE INCHES. TWELVE GAGE HANGER WIRE PER ASTM C 636 ITEM 2.3.4. LING PLANES WILL REQUIRE POSITIVE BRACING. PER ASCE 7-05 SECTION 9.6.2.6.2.2. ITEM f. BRACING IS THE USE OF VERTICAL STRUTS (COMPRESSION POSTS) AND SPLAY WIRES. BRAC1NGS IS REQUIRED FOR CEIUNGS OVER 1,000 S.F. AND NOT REQUIRED FOR CEILINGS UNDER THEY, ARE SURROUNDED BY FOUR WALLS AND BRACED TO STRUCTURE PER ASCE 7-05 SECTION BRACING SHALL BE 12' O.C. MAX. AND BEGIN WITHIN 6 FROM WALLS. PER C1SCA SEISMIC ZONES E TO BE WITHIN 2* OF THE CONNECTION OF THE VERTICAL STRUT TO SUSPENDED CEILING. PER MAY BE USED IN LIEU OF SPLAY WIRES. PER ASCE SECTION 9.6.2.6.2.2. 3 STUDS MIN. BOTTOM OF FINISHED CEILING ANCHOR BRACKET: 6*X16ga UNPUNCHED STUD TRACK, ATTACH TO 3 STUDS MIN FINISHED FLOOR VERTICAL STRUTS MUST BE POSITIVELY ATTACHED TO SUSPENSION SYSTEMS AND THE STRUCTURE ABOVE. PER CISCA 3-4. WALL MOLDINGS WALL MOLDINGS (PERIMETER CLOSURE ANGLES) ARE REQUIRED TO HAVE A HORIZONTAL FLANGE 2 WIDE. ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE WALL MOLDING, THE OTHER END SHALL HAVE A 3/4* CLEARANCE FORM THE WALL AND BE FREE TO SLIDE. PER ASCE 7-05 SECTION 9.6.2.4.2.2 ITEM b. MOULDING DIMENSIONS MUST BE CONSISTENT AND ALTERNATIVE CONNECTIONS ARE PERMISSIBLE WITH BUILDING MANANGEMENT AND CITY APPROVAL THE GRID SHALL BE ATTACHED AT TWO ADJACENT WALLS (POP RIVETS OR APPROVED METHOD). PER CISCA SEISMIC ZONES 3-4. THERE SHALL BE A MIN. 3/e CLEARANCE FROM THE END OF THE GRID SYSTEM AT UN-ATTACHED WAU.S. PER ASCE 7-05 SECTION 9.6.2.6.2.2 ITEM b. SPREADER (SPACER) BARS OR OTHER MEANS APPROVED BY LOCAL BUILDING DEPARTMENT SHALL BE USED TO PREVENT THE ENDS OF THE MAIN BEAMS AT PERIMETER WALLS FROM SPREADING OPEN DURING A SEISMIC EVENT. PERIMETER WIRES SHALL NOT BE IN LIEU OF SPREADER BARS. PER CISCA SEISMIC ZONES 3-4. WIRE TYING IS AN ACCEPTABLE ALTERNATIVE TO SPREADER BARS. SPREADER BARS ARE NOT REQUIRED IF A 90' INTERSECTING CROSS MAIN IS WITHIN 8* OF PERIMETER WALL HANGER (SUSPENSION) WIRES HANGER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 UNLESS COUNTER SLOPING WIRES ARE PROVIDED. COUNTER SLOPING WIRES TO BE A PAIR OF WIRES SLOPING AWAY FROM GRID MEMBER IN OPPOSITE DIRECTIONS AT A MIN. 45' ANGLE FROM PLANE OF CEILING. PER ASI1,4 C 636 SECTION 2.1.4 HANGER WIRES SHALL BE 12 GAGE AND SPACED e O.C. OR 10 GAGE SPACE 5' O.C. PER ASTM C 636. ANY CONNECTION DEVICE AT THE SUPPORTING CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS THAN 100 POUNDS. PER CISCA ZONES 3-4. BRACING WIRES SHALL BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL DESIGN LOAD, WITH A SAFETY FACTOR OF 2, WHICHEVER IS GREATER. PER CISCA ZONES 3-4 POWDER DRIVEN FASTENERS MUST BE APPROVED FOR THE APPROPRIATE LOADING. PER ASCE 7-05 SECTION 9.6.1.6.5. TERMINAL ENDS OF EACH MAIN BEAM AND CROSS TEE MUST BE SUPPORTED WITHIN 8" OF EACH WALL WITH A PERIMETER WIRE. PER CISCA ZONES 3-4. ELFZELMJELEffa LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS SHALL HAVE ONE 12 GAGE HANGER WIRE CONNECTED FORM THE FIXTURE TO THE STRUCTURE ABOVE. THIS WIRE MAY BE SLACK. PER CISCA SEISMIC ZONES 3-4. LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS AND LESS THAN 56 POUNDS SHALL HAVE TWO 12 GAGE WIRES ATTACHED AT OPPOSING CORNERS OF THE LIGHT FIXTURE TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. PER CISCA SEISMIC ZONES 3-4. UGHT FIXTURES WEIGHING MORE THAN 56 POUNDS SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE. THESE WIRES MUST BE TAUT. PER CISCA SEISMIC ZONES 3-4. PENDANT MOUNTED FIXTURES SHALL BE DIRECTLY SUPPORTED FROM THE STRUCTURE ABOVE USING 9 GAGE WIRE OR AN APPROVED ALTERNATE SUPPORT WITHOUT USING THE CEILING SUSPENSION SYSTEM FOR DIRECT SUPPORT. PER CISCA SEISMIC ZONES 3-4. TANDEM FIXTURES MAY UTILIZE COMMON WIRES. TERMINALS OR SERVICES WEIGHING 20 POUNDS BUT NOT MORE THAN 56 POUNDS MUST HAVE MO 12 GAGE WIRES CONNECTING THEM TO THE CEILING SYSTEM HANGERS OR THE STRUCTURE ABOVE. 'THESE WIRES MAY BE SLACK. PER C1SCA SEISMIC ZONES 3-4. TERMINALS OR SERVICES WEIGHING MORE THAN 56 POUNDS MUST BE INDEPENDENTLY SUPPORTED DIRECTLY FORM 'THE STRUCTURE ABOVE THESE WIRES MUST BE TAUT. PER CISCA SEISMIC ZONES 3-4. SEISMIC SEPARATION JOINTS FOR CEILING AREAS EXCEEDING 2500 S.F., A SEISMIC SEPARATION JOINT OR FULL HEIGHT WALL PARTMON THAT BREAKS THE COUNG SHALL BE PROVIDED UNLESS ANALYSES ARE PERFORM OF THE CEILING BRACING SYSTEM, CLOSURE ANGLES AND PENETRATIONS TO PROVIDE SUFFICIENT CLEARANCE. PER ASCE 7-05 ITEM 9.6.2.6.2.2D. SPECIAL INSPECTIONS SPECIAL INSPECTIONS SHALL BE SUBJECT TO SPECIAL INSPECTION REQUIREMENTS SPRINKLERS FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD PENE1RA1IONS SHALL HAVE A 2* OVERSIZE RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE MOVEMENT OF AT LEAST 1* IN ALL HORIZONTAL DIRECTIONS. FLEXIBLE HEAD DESIGN THAT CAN ACCOMMODATE 1 INCH FREE MOVEMENT SHALL BE PERMITTED AS AN ALTERNATE. PER ASCE 7-05 9.6.2.6.23.2 ITEM E. TYPICAL MIL. NOTES: 1. TYPICAL ANCHOR BRACKET ASSEMBLY FOR HANDRAILS, GRAB BARS & TOILET ACCESSORY ANCHORAGES. COORDINATE ANCHOR BRACKET LOCATION WITH ACCESSORY MANUFACURER MOUNTING INSTRUCTIONS. HARDWARE SUBSTITUTION ALLOWED W/ WRI I IEN PERMISSION SCRIBE TO WALL NOTE: PROVIDE FOUR (4) COAT HOOKS MOUNTED AT MAX. 4'-O" A.F.F. FOR ADA ACCESSIBILTY REQUIREMENTS AND SHELF DETAIL etor° 'IIIIIIIIIIIIlIIIIIIIIIIIIIIIlII BOTTOM OF STRUCTURE WHERE PART. 'TYPE IS INSULATED PROVIDE ENCAPSULATED ACOUSTICAL BATT WENDING 24" EACH SIDE OF PARTITION. PROVIDE MIN 25 GA STUDS & ANCHOR BRACKET ANCHORAGES. DOUBLE STUDS END OF PARTMONS. 6"x16 GA UNPUNCHED STUD TRACK WITH FLANGES COPED AT VERTICAL STUDS. ATTACH TO TWO STUDS MIN. & EXTEND CMIN BEYOND MOUM1NG POINT EACH DIRECTION. 1 X 2 PAINT GRADE HDWD. NOSING, PAINTED K&V 660 S.S. (1-1/16" O.D. POLE & K&V _#784 ESCUTHEON @ EACH END MS © 16"0.C.- BACK & END SUPPORTS FACE OF WALL PARTITION ANCHOR BRACKET (4 BACK & END PARTITIONS 2'XeX12" MIN. LEG AT STRUCTURE - ATTACH W/2 POWDER DRIVEN FASTENERS PER BRACE OR OTHER APPROVED METHOD PLENUM HEIGHT OF 5'-0" OR LESS 2 1/2'x25 GA METAL STUD BRACING 0 8r-0 OC TO STRUCTURE DIRECTION ALTERNATE. PARTMONS PERPENDICULAR TO PARTITION ACT AS BRACE PLENUM OF 5'-0" TO 10'-0" SHALL USE NESTED OR BACK TO BACK 3 25 GA. STEEL STUDS. ABOVE 1V-0" OR PLENUM. CONTACT ARCHITECT FOR ADDMONAL INFORMATION. MAX PARTITION WEIGHT 15Ibs./P.S.F. SUSPENDED CEILING AS SCHEDULED TAPEABLE MET. TOP TRACK ATTACHED TO BRACING W/2 SELF-TAPFING SM. SCREWS 0 48 cc, AND ve PIPE SLEEVES INSULATION UON ON PLANS 3 1/2" X 25 GA METAL STUDS 0 24' CC, TO 10'-r MAX. HEIGHT. POWDER DRIVEN FASTENER 0 2e oo MET. RUNNER TRACK SEALANT CONCRETE SLAB GROUP 7 PAIRED, PASSAGE IATCHSET NON-RATED DOOR TYPES EQ. j4 , EQ. WIDTH WIDTH GLAZING AS SCHEDULED PAINT GRADE --- WOOD FRAME GLAZING AS SCHEDULED E = EXISTING, MATCH ALL DOSING CONDMONS PAINT GRADE WOOD FRAME 1/4" TEMPERED GLASS FLUSH S.C. PAINT GRADE WOOD DOOR -PAINT GRADE WOOD FRAME GLAZING AS SCHEDULE) RNNT GRADE WOOD FRAME WIDTH FRAMELESS GLASS SUPPORT 1/2" TEMPERED GLASS SEE OTHER EXAMPLES IN LOBBY PAINT GRADE WOOD FRAME FLUSH S.C. PAINT GRADE WOOD DOOR B/S FINISH NEW HERCUUTE TEMPERED GLASS DOORS. B/S FINISH SEE OTHER EXAMPLES IN BUILDING 258B 200A DEVICES SHOWN STACKED IN PLAN ARE TO AUGN VERT. AS SHOWN BELOW ORK SURFACE SECTION AT LOCATION AS DIMENSIONED ON PLAN; OR NEXT TO DOOR / OPENING AS DIMENSIONED BELOW FIRE ALARM STROBE FRAME WHERE OCCURS ROOM SIGNAGE, ETC. 'THERMOSTAT CARD READER WHERE OCCURS HARDWARE LATCH FINISHED FLOOR TELEPHONE OUTLET ELECTRICAL OUTLET ENERAL DEVICE ALIGNMENT .UGHT & PROJECTION SCREEN SWITCHES, WALL MOUNTED OCCUPANCY SENSOR NOTE; COORDINATE ANCHOR BRACKET LOCATIONS W/ CASEWORK & EQUIPMENT WHERE SCHEDULED, AND MANUF. MOUNTING INSTRUCTIONS TYPICAL ANCHOR BRACKET FRAMING 1008.1.14 ACCESS-CONTROLLED EGRESS DOORS. THE ENTRANCE DOORS IN A MEANS OF EGRESS IN BUILDINGS WITH AN OCCUPANCY IN GROUP A, B, E, M, R-1 OR R-2 AND ENTRANCE DOORS TO TENANT SPACE IN OCCUPANCIES IN GROUPS A; B, E, M, R AND R ARE PERMITTED TO BE EQUIPPED WITH AN APPROVED ENTRANCE AND EGRESS ACCESS CONTROL SYSTEM WHICH SHALL BE INSTALLED IN ACCORDANCE WITH ALL OF THE FOLLOWING CRITERIA: 1. A SENSOR SHALL BE PROVIDED ON THE EGRESS SIDE ARRANGED TO DETECT AN OCCUPANT APPROACHING THE DOORS. THE DOORS SHALL BE ARRANGED TO UNLOCK BY A SIGNAL FROM OR LOSS OF POWER TO THE SENSOR. . LOSS OF POWER TO THAT PART OF THE ACCESS CONTROL SYSTEM WHICH LOCKS THE DOORS SHALL AUTOMATICALLY UNLOCK THE DOORS. . THE DOORS SHALL BE ARRANGED TO UNLOCK FROM A MANUAL UNLOCKING DEVICE LOCATED 40 INCHES TO 48 INCHES (1016mm TO 1219mm) VERTICALLY ABOVE THE FLOOR virniIN 5 FEET (1524mm) OF THE SECURED DOORS. READY ACCESS SHALL BE PROVIDED TO THE MANUAL UNLOCKING DEVICE AND THE DEVICE SHALL BE CLEARLY IDElfaRED BY A SIGN THAT READS *PUSH TO EXIT.* WHEN OPERATED, THE MANUAL UNLOCKING DEVICE SHALL RESULT IN DIRECT INTERRUPTION OF POWER TO THE LOCK-INDEPENDENT OF THE ACCESS CONTROL SYSTEM ELECTRONICS-AND THE DOORS SHALL REMAIN UNLOCKED FOR A MINIMUM OF 30 SECOND. 4. ACTIVATION OF THE BUILDINGS FIRE ALARM SYSTEM, IF PROVIDED, SHALL AUTOMATICALLY UNLOCK THE DOORS, AND THE DOORS SHALL REMAIN UNLOCKED UNTIL THE FIRE ALARM SYSTEM HAS BEEN RESET.. 5. ACTIVATION OF THE BUILDINGS AUTOMATIC SPRINKLER OR FIRE DETECTION SYSTEM, IF PROVIDED, SHALL AUTOMATICALLY UNLOCK THE DOORS. THE DOORS SHALL REMAIN UNLOCKED UNTIL THE FIRE ALARM SYSTEM HAS BEEN RESET. - 6. ENTRANCE DOORS IN THE BUILDINGS WITH AN OCCUPANCY IN GROUP A, B, E AND M SHALL NOT BE SECURED FROM THE EGRESS SIDE DURING PERIODS THAT THE BUILDING IS OPEN TO THE GENERAL PUBUC. IBC 1008.1.3.4 1/4 4- N-RATED FLOOR TO CEILING PARTITION 4" 12" 3" = 1 -0 1 PRIVACY LOCKSET W/ OCCUPANCY SENSOR 1.5 PAIR HINGES 1 WALL-MOUNTED DOOR STOP 1 PUSH-PULL 1.5 PAIR HINGES 1 WALL-MOUNTED DOOR STOP 2 KICK PLATES EACH SIDE GROUP 9 SINGLE, PUSH-PULL NON-RATED SIDELIGHT/GLAZING SCHEDULE SIDELJ 7-45 7-4 7 0' T-0 FULL HT FULL HT FULL HT FULL HT FULL HT GHT 2 T-6* 3 4 6 VARIES 1 DUMMY PASSAGE LATCHSET'S W/ ROLLER CATCHES 3 PAIR HINGES 2 OVERHEAD DOOR STOP 1 DOUBLE DOOR SEAL 1 TFIRESHOU) 1 DOOR BOTTOM 1 ASTRAGAL 1/4* TEMPERED 1/4* TEMPERED 1/4* TEMPERED 1/4* TEMPERED 1/4* TEMPERED 1/2* TEMPERED E = DUSTING, MATCH ALL EXISTING CONDMONS WD WD WD WD ALUM SIDELIGHT/GLAZING TYPES VERIFY USE OF ROLLER CATCH WITH Acousnc SEAL CLEAR STORY ABOVE DOOR TO BE FULL HT. VERIFY SILL HEGHT VERIFY SILL HECHT VERIFY SILL HEGHT VERIFY SILL HECHT MATCH EXISTING CONDMONS .12 212 213 214 215A 216 217 219 220 221 223 226 227 228 229 230 232 233 234 235 236 238 239A 2398 241 258A 261 262 263 264 266 267 268 269 270 271 272 273 274 275 276 277 DOOR & HARDWARE GENERAL NOTES PROVIDE YALE HARDWARE WITH LEVER TO MATCH DUSTING, US 626 BRUSHED CHROME FINISH. SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTAUATION. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME HEAD. REFER TO SPECIFICATIONS FOR CLEARANCES. DOUBLE DOOR NOMINAL WIDTH INDICATES 2 DOOR LEAVES OF EQUAL WIDTH, U.O.N. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH - BOLTS. DOOR / HARDWARE SHALL COMPLY WITH ALL APPLICABLE IBC & ACCESSIBILITY REQUIREMENTS 6. ALL DOMING * A * TYPE DOORS TO HAVE CUT OUT IN EXISTING DOOR FOR NEW VISION PANEL 7, SPECIFICATIONS FOR ACOUSTIC HARDWARE: PEMKO S88 DOUBLE DOOR SEAL • PEMKO 2001 THRESHOLD • PEMKO 430 AUTOMATIC DOOR BOTTOM PEMKO 355S ASTRAGAL DOOR SCHEDULE DOOR 6'-0" 3 S-0" S-0" S-0" -o 3 S-0" S-0" S-0" S-0" 3 S-0" 3 0 S-0" 3 3 S-0" S-0" 3'-0" S-0 S-0" S-0" 3'-O" 3 S-0" S-0" S-0" S-0" S-0" 3 S-0" 3 FULL HT T-0" 7-0" 7-0" r-O" 7'-0" 7 '4 1 7-0" 7 7 7 7-0" 7'-0" 7 7-0" 7 T-0" 7 7-0" 7'-0" T-0" T-0" 7'-0" 7'-0" 7-0" 7'41" 7'-0" PR' D N • D •1 • ,wm, „mom. /1111... /111M. 41111M. I.. AWN. INN. ■Mb■ Ia. AM. AMR. AMOK INN. AM... AIM. A A A A A A A A A A A A 2 WD 5 5 5 WD 5 WD WD 5 WD WD 6 5 5 4 5 WD - WD WD WD WD WD WD WO WD WD WD WD WD WD WD VERIFY OR PROVIDE PROVIDE SOUND INSULATED DOOR, ACOUSTICAL SEAL AND SHOES. PROVIDE FILM ON GLASS PANEL PROVIDE FILM ON GLASS PANEL VERIFY OR PROVIDE E WD WD VERIFY OR PROVIDE VERIFY OR PROVIDE VERIFY OR PROVIDE VERIFY OR PROVIDE MODIFY FOR CARD READER ACCESS ASSEMBLY MODIFY FOR CARD READER ACCESS ASSEMBLY MODIFY FOR CARD READER ACCESS ASSEMBLY VERIFY OR PROVIDE VERIFY OR PROVIDE VERIFY OR PROVIDE 6 WD - VERIFY LOCK, PROVIDE ACOUSTCAL SEAL SHOES AND THRESHOLD. 5 5 5 WD E WD VERIFY OR PROVIDE 9 WD WD - 9 WD 3 WD PROVIDE NEW CARD READER ACCESS ASSEMBLY E WD WD 5 WD 5 WD WD WD 5 WD WD 5 WD 5 WD 1 ALL WIRE TIES SPACED 4' 0.C., CHANGES IN CD LATERAL FORCE LATERAL FORCE 1,000 S.F. IF 9.6.2.6.2.2 ITEM LATERAL FORCE 3-4. SPLAY WIRES AR CISCA 3-4. RIGID BRACING 1. LOCATED SWITCHPLATES, ELECTRICAL AND TELEPHONE WALL OUTLETS AT NEAREST STUD FROM SCALED LOCATION ON PLAN, UNLESS SPECIRCALLY DIMENSIONED ON PLAN, ELEVATION, OR LOCATION AS PER DIAGRAM ABOVE. 2. CENTER FIRE ALARM STROBES DIRECTLY ABOVE ARE DMNGUISHER CABINETS WHERE BOTH OCCUR. 12 GA. B CROSS RUNNER N RUNNER 'STANCE FROM B WIRES TO CROSS ROVIDE ACT SUSPENSION GRID TO COMPLY IBC SEC-1621 MINIMUM STANDARD: ECTION 9.6 ASCE 7. SEE NOTES ON M/A.9.2. REFERENCED SOURCES PER HIERARCHY: 2006 IBC (INTERNATIONAL BUILDING CODE), AMERICAN SOCIETY OF TESTING MATERIALS (ASTM C 635, 'TM C 636), AMERICAN SOCIETY OF CML ENGINEERS (ASCE 7-05) AND CEILINGS AND INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION (C1SCA). PARTMONS NAT ARE TIED TO THE CEILING AND ALL PARTITIONS GREATER THAN 6 FEET HEIGHT SHALL BE LATERALLY BRACED TO STRUCTURE. BRACING SHALL BE INDEPENDENT OF CEILING SPLAY BRACING SYSTEM. PER IBC 1621.1.2 ALL MAIN BEAM ALL CROSS TEES SHALL BE CAPABLE OF CARRYING THE DESIGN LOAD WM-LOUT 'WEEDING DEFLECTION EQUAL TO 1/360 OF ITS SPAN. PER MCA ZONES 3-4 THESE REQUIREMENTS ARE INTENDED FOR SUSPENDED CEILINGS INCLUDING GRID, PANEL OR TIE LIGHT FIXTURES AND AIR TERMINALS WEIGHING NO MORE THAN 4 POUNDS PER S.F., PER ASCE 7-05 ITEM 9.6.2.6.1. LATERAL FORCE SPLAY WIRES SHALL BE 12 GAGE ATTACHED TO THE MAIN BEAM. WIRES ARE ARRAYED 90' FROM EACH OTHER AND AT AN ANGLE NOT TO EXCEED 45' FROM THE PLANE OF THE CEILING. PER CISCA SEISMIC ZONES 3-4. A Tenant Improvement for: SAI3EY 12201 TUKVVILA INTERNATIONAL BLVD. SUITE 400 SEA'TTLE, VVA 98168 Tenant: APB R1VERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKVV1LLA, WA 98168 burgess design lin teri ors o architecture 1626 Fifth Avenue Suite 500 Seattle . WA 68101 TEL 206.587.7120 FAX:206. 587.7122 M reproduction & intellectual property rights reserved c 2009 Professional seal No. issue Description REVIEW SET PERMIT SET REVISION 1 REVISION 2 7196 /2\ Drawn by: MK/TS Reviewed by: Project No: 09-S804-00 RECEIVED JUL 23 2009 PERMIT CENTEF KIP G. KOLODZIEJSKI STATE OF WASHINGTON I REGISTERED ARCHITECT DOOR SCHEDULE/ SIDELITE SCHED DETAILS Date 6/22/09 6/25/09 07/15/09 07/22/09 KK City of Tukwila BUILDING DIVISION Original drawing is 30" x 42". Scale entities accordingly if reduced A91 VIEWED FOR E COMPLIANCE APPROVED JUL 28 alua 11111111111111 11111111111111 LONGEST COMMON PATH OF EGRESS TRAVEL: 54'-11'' REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE Revisions will require a new plan submittal and may include additional plan review fees. A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 KIP G. KCLODZ!EJSKI STATE OF WASHINGTON. SYMBOL LEGEND — - EGRESS PATHWAY FOR EMERGENCY LIGHTS. DESIGN BUILD CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTS, PER 1006. VERIFY PATHWAY WITH FINAL FURNITURE LAYOUT. GENERAL NOTES 1. _ THIS TENANT IMPROVEMENT TO BE PERMITTED AS MIXED OCCUPANTS WITH UNSEPARATED USES. PER IBC SECTION 302.1 THE ORIGINAL BUILDING WAS PERMITTED WAS A V —N FIRE SPRINKLERED BUILDING IN 1987 WITH UNLIMITED AREA WITH 60' YARDS. ON ALL SIDES. WE PROPOSE TO CHANGE THE BUILDING CLASSIFICATION, BASED ON 2003 UBC, TO CONSTRUCTION TYPE VB FIRE SPRINKLER WITH UNLIMITED AREA PER SECTION 507.3 "PNO STORY." THE AREAS OF A TWO STORY GROUP B, F, M OR S BUILDING SHALL NOT BE LIMITED WHEN THE BUILDING IS PROVIDED WITH AN AUTOMATIC SPRINKLERS SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 THROUGHOUT AND IS SURROUNDED AND ADJOINED BY PUBLIC WAYS OR YARDS NOT LESS THEN 60 FEET IN WIDTH. EXITS ARE GREATER THAN 1/3 DISTANCE OF DIAGONAL (1015.2.1 X 2 SEPARATE PERMIT REQUIRED FOR: 1" Mechanical Electrical Plumbing Gas Piping City of Tukwila I DING DIVISION RECEIVED CITY OF TUKWILA SEP 0.1 2009 PERMIT CENTER PELF CO If Permit No. . I L 1 Plan review approval is subject to errors and omissions. Approval of construction d w I does not authorize the violation of any adopted • • e or o ce. Receipt of approved Field Copy and con lilt ► i` is acknowledged: By/ Date: g - -2-007 City Of Tiiicwila BUILDING DIVISION REVISIO poyuI burgess design I interiors Q architecture 1326 Fifth Avenue Suite 500. Se the . WA 98101 TEL: 206.587.7120 FAX:206. 587.7122 M reproduction & intellectual property rights reserved c 2009 Drawn by: MK /TS Reviewed by: Project No: 09- SB04 -00 EGRESS PLAN 7/15/09 7/22/09 8/04/09 KK Original drawing is 30" x 42 ". Scale entities accordingly if reduced A Tenant Improvement for: SABEY 12201 TyKWILA INTERNATIONAL BLVD. SUITE 4�O SEATTLE, WA 98168 Tenant APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 burgess design I interiors � architecture 1326 Fifth Avow Suite 500 . Seittle . WA 88101 TEL: 206.587.7120 FAX:206. 587.7122 All reproduction & intellectual property rights reserved c 2009 FELE COPY Permit No. 12 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approve?F Copy :,.11 ,, -111?.111 - owledged: Professional seal By Date. 7A City Of lbktvila BUILDING D ION No. Issue Description REVIEW SET PERMIT SET 7196 REGISTERED ARCHITECT KIP G. KOLODZIEJSKI STATE OF WASHINGTON P D r r o a _w by: : M 0 K 9 /T s S B04_0 R o eviewed by: Date 6/22/09 - 6/25/09 KK COVER SHEET / PROJECT INFORMATION Original drawing is 30" x 42". Scale entities accordingly if reduced G.0 .0 GENERAL NOTES ARCH / INTERIOR ABBREVIATIONS BUILDING SUMMARY PROJECT TEAM 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT "GENERAL CONDITIONS," AND BUILDING STANDARDS AS PROVIDED BY THE BUILDING OWNER. 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT " TRADES. 3. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. 4. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWING ONLY WILL NOT SATISFY THIS REQUIREMENT. 5. ALL MODIFICATIONS, REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS AUTHORIZED IN WRITING BY OWNER AND/OR ARCHITECT. 6. WITHIN FIVE (5) BUSINESS DAYS OF START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY IN WRITING BOTH THE ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD TIMES; PAYMENT OF RUSH FABRICATION OR DELIVERY CHARGES OUT OF SEQUENCE . INSTALLATION, OR DELAY OF INSTALLATION - OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. 8. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS. 9. THE USE OF WORD "PROVIDE SHALL ALWAYS MEAN, "FURNISH AND INSTALL, CONNECT OR SECURE" AS REQUIRED. 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL INCLUDE DELIVERY LEAD TIMES OF CONSTRUCTION ITEMS, AND START AND COMPLETION DATES OF EACH PHASE. THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS. 13. ACCESS TO AND FROM THE PROJECT SITE, SPECIAL CONDITIONS, NOISY WORK, TIMING OF WORK, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, RELOCATION OF EXISTING EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC., MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. - 14. ADEQUATE CLEANUP, PROTECTION AND PLACEMENT OF ANY CEIUNG TILES AND/OR OTHER DISRUPTION TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT THE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS. 15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: COMMON HALLWAYS, FREIGHT ELEVATOR VESTIBULES, ETC. 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 17. UPON COMPLETION OF ALL CONSTRUCTION, THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH ONE SET OF "RECORD" AS-BUILT DRAWINGS. 18. ALL MATERIALS TO BE NEW UON. 19. PATCH ALL DISTURBED AND/OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS REQUIRED FOR FINISHED APPEARANCE. 20. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY BACKING, BLOCKING, AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL FIXTURES, CASEWORK AND ALL OTHER ITEMS REQUIRING IT. 21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. 22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND REQUIRE ARCHITECT'S REVIEW PRIOR TO INSTALLATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW. , 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS . FOR REVIEW ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION. SUBMIT TO . ARCHITECT AT LEAST THREE (3) COPIES FOR REVIEW. : . 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE LIST. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. ADJ - ADJUSTABLE MECH - MECHANICAL AFF - ABOVE FINISH FLOOR MEZZ - MEZZANINE ALT - ALTERNATE MFR - MANUFACTURER ALUM - ALUMINUM MIN - MINIMUM APC - ACOUSTICAL PANEL CEILING MISC - MISCELLANEOUS APPROX - APPROXIMATE ARCH - ARCHITECTURAL MTD - MOUNTED ACT - ACOUSTICAL CEILING TILE MTh - METAL AV - AUDIO VISUAL N/A - NOT APPLICABLE BLDG - BUILDING NIC - NOT IN CONTRACT - BOT - BOTTOM NTS - NOT TO SCALE CAB - CABINET OC - ON CENTER CL - - CENTER LINE OFF - OFFICE CLG - CEILING OPNG - OPENING CLR - CLEAR OVHD 7 OVERHEAD COL - COLUMN P - PAINT CONC - CONCRETE PART - PARTITION • CONF - CONFERENCE PERF --- PERFORATED DEMO - DEMOLITION PERIM - PERIMETER DEPT -- DEPARTMENT PERP - PERPENDICULAR DF - DRINKING FOUNTAIN P1-AM - PLASTIC LAMINATE DIA - DIAMETER PLYWD - PLYWOOD DIFF - DIFFUSER QTY - QUANTITY DIM - DIMENSION DTL - DETAIL (R) - RELOCATED DW - DISHWASHER RA - RETURN AIR DWG - DRAWING RCP - REFLECTED CEILING PLAN REC - RECESSED EA EACH EL - ELEVATOR REF - REFERENCE ELEC - ELECTRICAL REFR - REFRIGERATOR ELEV - ELEVATION REL - RELOCATE EQ - EQUAL REV - REVISION OR REVISED - EQUIPMENT RM - ROOM OCT - EXTERIOR RO - ROUGH OPENING FA - FIRE ALARM RTD - RATED FD - FLOOR DRAIN SCHED - SCHEDULE FE - FIRE EXTINGUISHER SF - SQUARE FEET/FOOT FEC - ARE EXTINGUISHER CABINET SHT - SHEET FFE - FINISH FLOOR ELEVATION SIM - SIMILAR FIN - FINISH SPEC - SPECIFICATION FLUOR - FLUORESCENT SPKLR - SPRINKLER FLR - FLOOR SPKR - SPEAKER FO -,,, FACE OF SQ - SQUARE FOIC - FURNISHED BY OWNER, INSTALLED STD - STANDARD BY. CONTRACTOR • STL - STEEL FTIC - FURNISHED BY TENANT, INSTALLED STOR - STORAGE BY CONTRACTOR STRL - STRUCTURAL FURR - FURRING STRUC - STRUCTURAL GA - GAUGE GC - GENERAL CONTRACTOR TBD - TO BE DETERMINED GL - GLASS TEL - TELEPHONE OR TELECOM GWB - GYPSUM WALLBOARD TEMP - TEMPERED HC - HANDICAPPED THK - THICKNESS UPS SYMM - SYMMETRICAL HDW - HARDWARE TO - TOP OF HM - HOLLOW METAL (STEEL FRAME) TOS - TOP OF SLAB HR - HOUR Typ - TYPICAL INCL - INCLUDED OR INCLUDING - UON UNLESS OTHERWISE NOTED INFO - INFORMATION - UNINTERRUPTED POWER SUPPLY INSUL - INSULATION VCT - VINYL COMPOSITION TILE LAV - LAVATORY - VERIFY IN FIELD . LF - LINEAR FOOT VIF MATL - MATERIAL WI' - WITH - MAXIMUM wc - WATER CLOSET MDF - MEDIUM DENSITY FIBERBOARD wp - WOOD W/0 - WITHOUT 1. PROJECT ADDRESS: AVIATION PARTNERS BOEING RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILA, WA 981 68 2. APPLICABLE CODES 8c ORDINANCES: • A BUILDING CODES INTERNATIONAL BUILDING CODE - 2006 B REGULATIONS 8c ORDINANCES C ACCESSIBILITY INTERNATIONAL BUILDING CODE - 2006 ICC/ANSI 117.1 ACCESSIBLE 8c USABLE BUILDINGS AND FACILITIES - 2003 3. GENERAL BUILDING DESCRIPTION: TYPE OF CONSTRUCTION: VI3 (EXISTING UNLIMITED AREA 507.4) FIRE RESISTIVE SYSTEM: SPRINKLERED PER NFPA13 QUICK RESPONSE HEADS OCCUPANCY TYPE: 'B' OFFICE 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: EXIT STAIR ENCLOSURES: 1 HOUR ' CORRIDORS: NON RATED, QUICK RESPONSE SPRINKLER HEADS (1017.1) • EXITS: APPROXIMATE AREA OF CONSTRUCTION: 12,500 SQUARE FEET TOTAL APPROXIMATE SUITE AREA: 28,990 SQUARE FEET TOTAL APPROXIMATE FLOOR AREA: 87,500 SQUARE FEET OCCUPANT LOAD FACTOR: 100/SQUARE FEET NUMBER OF TOTAL PROPOSED OCCUPANTS: 288 IN SUITE NUMBER OF EXITS REQUIRED: 2, 2 PROVIDED MINIMUM EGRESS WIDTH REQUIRED: 3'-8" COMMON PATH OF EGRESS TRAVEL: 100' (1013.3 X 1) 6 PROJECT DESCRIPTION: NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT NEW PARTITIONS, DOORS, FINISHES. TENANT: GENERAL CONTRACTOR: AVIATION PARTNERS BOEING TBD 7299 PERIMETER ROAD S SEATTLE, WA 98108 PLUMBING ENGINEER: TEL 206.830.7699 ATTN: DEAN POOR TBD - BIDDER DESIGN BUILD BY G.C. MECHANICAL ENGINEER: . ARCHITECT/DESIGNER: TBD - BIDDER DESIGN BUILD BY G.C. BURGESS DESIGN, INC. 1326 - 5TH AVENUE, SUITE 500 ELECTRICAL ENGINEER: SEATTLE, WASHINGTON 98101 TBD - BIDDER DESIGN BUILD BY G.C. TEL: 206.587.7120 FAX: 206.587.7122 FIRE/UFE SAFETY ENGINEER: ATTN: KIP KOLODZIEJSKI TBD - BIDDER DESIGN BUILD BY G.C. BUILDING MANAGER: SABEY BUILDING NAME 1 2201 TUKWILA - INTERNATIONAL BLVD. SUITE 400 PLUMBING; MECHANICAL, ELECTRICAL, SEATTLE, WA 981 68 . LIFE SAFETY PERMITS UNDER SEPARATE TEL 206.281.8700 SUBMITTALS. FAX: 206.282.9951 ATTN: KARA ANDERSON LEGAL DESCRIPTION / PAR NO. PARCEL NUMBER: 0423049190 LEGAL DESCRIPTION: PORTION OF SE 1/4 - BEGIN SW CORNER OF GOV LOT 11 IN SE 1/4 OF SECTION 04-23-04 TH S 89-22-06 E 988.27 FT TH N 14-45-08 W 477.09 FT TO INTERSECTION WITH N LINE OF S 460 FT OF GOV LOT 11 & NELY MARGIN OF PRIMARY STATE HIGHWAY NO 1 TH N 14-45-08 W 689.81 FT TO SWLY MARGIN OF 200 FOOT SEATTLE TRANSMISSION LINE TH N 14-45-08 W 22.70 FT TAP OF SPIRAL CURVATURE TH CONTINUING ALONG NELY MARGIN ALONG SPIRAL CURVE TO LEFT THE CHORD BEARING N 15-07-51 W 152.94 FT TAP OF SIMPLE CURVATURE TH ALONG NE MARGIN N1NLY 340.67 FT ALONG ARC OF NON TANGENT CURVE TO LEFT RADIUS OF 3970 FT RADIUS POINT BEARING S 74-07-22 W THRU C/A OF 04-55-00 TH CONTINUING ALONG SAID NELY MARGIN N 11-24-57 E 327.11 FT TO POINT OF BEGINNING TH N 11-24-57 E 61.40 FT TAP OF SIMPLE CURVE TH CONTINUING ALONG SAID NELY MARGIN NWLY 191.94 FT ALONG ARC OF NON TANGENT CURVE TO LEFT RADIUS OF 4190 FT RADIUS POINT BEARING S 64-42-23 W THRU C/A OF 02-37-29 TH N 27-01-05 E 89.78 FT TH N 48-11-59 E 442.51 FT TH S 41-52-02 E 881.11 FT TH S 48-05-28 W 406.87 FT TH N 41-52-51 W 627.47 FT TH S 48-11-44 W 218.98 FT MA TO POB - (PORTIONS OF LOTS 1 et 2 OF K C SHORT PLAT NO REVIEWED FOR CODE COMPLIANCE ! APPROVED JUL 1 7 2009 F6 City of ila BUILDING DIVISION 588023 RECORDING NO 9006050697 - - LOT 1 OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L96-0002 RECORDING NO 9707090733 STREET MAP DRAWING INDEX \ DRAWING ISSUED w < „,. 0 -; btetS it5 al ,.„ . ... a) '.... 01 CN1 *... c.0 a) '..., if) CV '--, (0 : _ ssoo$ GENERAL .. • _ X G.0.0 COVER SHEET / PROJECT INFORMATION X G.0.1 PROJECT NOTES .•._s S P.erri, X X G.0.2 SITE PLAN X X G.0.3 EGRESS PLAN ,r.- s Nortsk St ,' S % ARCHITECTURAL / INTERIORS X X A.1.1 DEMOLITION PLAN /02nd ST% S 1.03rd St. X X A.2A.1 CONSTRUCTION PLAN A.28.1 REFLECTED CEILING PLAN 10 th° X X A.2C.1 POWER et DATA PLAN Mit. A.2D.1 FINISH FLOOR PLAN 106ttv , 8.),„, A.9_1 DOOR SCHEDULE / SIDELIGHT SCHEDULE / DETAILS . , ,,,.': - . fc .. .. „._. --.....::::':,: ' ,, 7. -- "*AC ::: ‘ , .- $1.07th'SC .. , 07th - 71 - wam Ii : :,-.---, , ... „ - , ,: . :: . , ,, - ,. , , . . . , . r, .,,, , .. . . K. . i .. :• , ... .0 ::::, , ,.. - . : .,,,,i,:, ..:.„: .... : . :.: , Y 0 -, SYMBOLS DEFINITIONS AND DIMENSIONS KEY PLAN / FLOOR PLATE /32"- 39' 0 A. DEFINITIONS: AVIATION PARTNERS BOEING RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET ... TUKWILA, WA 98168 SECOND FLOOR AHEA...Q.E_INDES 1. "TYPICAL" OR "PIT INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. 2. "SIMILAR" OR "SIM." INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 3. "AS REQUIRED" INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS. 4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN ' STRAIGHT, TRUE, AND PLUMB RELATION ADJACENT MATERIALS. 5. "CLEAR" INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF PARTITIONS. B. DIMENSIONS: ELEVATION REFERENCE SYMBOL i i INDICATES FINISHED i ' SURFACES TO ALIGN U DETAIL ID DRAWING TITLE BAR A.06.XX DETAIL IDENTIFICATION DRAWING SHEET NO TITLE D GRAPHICAL SCALE SECTION REFERENCE SYMBOL TITLE . DM I , '.''7.1 ''' .= :Ps:W:il .: 11111111 lig , SHT FLOOR ELEVATION SYMBOLS . I/ I If -0 +1 -0 NOMINAL FLOOR DETAIL REFERENCE SYMBOL (I) 92 7 .----- ELEVATION HEIGHT (ABOVE/BELOW) DM BUILDING SPACE / ROOM ID t vitmatavt.s.gwq :i: ,VaTiii-fROPITAI :LIHOili thar :,., ,:,,,,,g41.7.E.mooz,:z1,-,t Rolic 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING CONSTRUCTION, CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED. 2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING PRIORITY ORDER. A. STRUCTURAL DRAWINGS B. LARGE SCALE DETAILS C. SMALL SCALE DETAILS D. ENLARGED PLANS AND SECTIONS E. FLOOR PLANS 3. MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE REQUIREMENTS SHALL BE MAINTAINED. 4. FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE . STRUCTURAL SLAB, UNLESS OTHERWISE NOTED. 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR - "AFF". 6. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC CEIUNG GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES, UNLESS OTHERWISE NOTED 7. DOCUMENTS ARE DRAWN DIAGRAMATICALLY, AND SCALED DIMENSIONS ARE APPROXIMATE. DIMENSIONS SHALL INDICATE REQUIRED SIZE, CLEARANCES, AND RELATIONSHIPS ARE INDICATED BY DIMENSIONS AS NOTED. . a . I SHT ''ZF:Akte.,.4', II OFFICE . SPACE NAME il - COLUMN AND/OR GRID LINE SYMBOL I 1127 I -0 SPACE NUMBER -.' .. -- .. ' ' ' ' - . . . '3'''' , -4-,,,r-cre-,,,,..r.:,-..1:..,-.....---, ..».. ....-. . :ii:%:ig ' : ' :-W , iing;g 2 ,L;;;,:t - ,;=: ' ,M- ' : DIMENSION UNE: 20' - DOOR 0 SYMBOL 0 .- 0 dill - Iii ilFP„, It Illi Fi 444 V g ,i,-' '.'' i:;. .:-&-:=&, a • . !':-IalaiTmw-elagfirput: IR, :,,,,, :.,. , ,,,....;g:V.L...0V - ,;;, : - .,.....--- ig k til*It5466ftMOIft'%gif g :;;---:., _ ie w_,=.-_,4 :..ari...., IP sr i -- a , 8 - •i=444: - at . NEL dri it L. ANGLE DOCUMENT SHEET SYMBOL 0 --**- KEYED SHEET NOTES :< MSTE,45::: i:iiit: • - - ,.,..„,,:.,,,„..„,„,,,,,,,,,:.;,...:,„,.:,,,,,„ eip rar . . ,,,, z.--,:, [ .... '' ' ' --"-- --- • :::?-: „.,, ...a0s.':_ af,'-- ,t:i.Fze i _ ! ..- . 1W 1111 . . _;._..;;;._.. --- © AT GLAZING SYMBOL Q CENTERLINE REVISION NUMBER A _ '0 ,, 7 7 . k : . ,, -4 . '."'' V4.. - iml-.:7&0"(;,.47g.1:7 Ati - MT-wifflk I. „ 1 ,,r,, :?., ;;!..s.afalgiNK W ''''' - i3 . '&75""` - n . _ z. = c i ili ' I. ..1 ' 1 i . pi MI , I' I I: ir 1 4. --_, '. ' _di EXIT , .:1:11:::_ki. - -.giug . .-*::3A-: - _ , - IF 1 4 - . - It II EXIT ■\ - ■-.4a Ill NE , IN' 4' : ,.,,,, ;1 ,-; . 1 i i . ir/ 111P ;1 . :.--,- ...0.0. -,, Iii . _ , cjy.„. 4.- 41 , kJ .L.;::%:.tifr ExIT EXIT P IT II nffeEllfrb , titm 3 a MOD TUKVVILA PUBLIC WORKS 'e-. . , :.----- -•:'',, so 's . : 4=q - Z : FE'Maa_ 'et' '' 7 :17 7 ' 7 7..7 1 .:“.- " ?:::a1:-7 agi'gi-wD::; ',=- li" ' .i1. , '- - , i • - -- - -;. , ,-'zi.:.-- - .-...---,:... , ..: . -',:tt„ -7. IF .: _ , - ..:■■.,''..:6 i A 4 ---,-47 . .;.it.--eig:s; - .:3 , 1 ._,-„;'4 ' a A _ , ff * k, --77 6. '. :?"'- ti *Z 1 .':7.-:-.'.;.ii-IW'''''r' tlEit argOVW-eili-ca _ yi , m - -,E- _ .,,,,,,• 'Pg.105-4; ..- , W- ,.b, tel4 ,',24- iS ,,7-v . - .„,,,,,:, ,. , g , i,far-4-fifff.E,I :NO ' #"-- . ' ,- ,UK -- V4,-?..:- 8. :,, ,VA-7 •-• _ ....,,, 1 7. 3 r1-t7)gWigogg, , * , ,,---4 - 9f -- • - .... .,-,..L, -14- . 111111111:3 111111111U . -'--:-,: 2 EIIIIIIIIIIIIIML B11111111111111 11111111111111 SEPARATE PERMIT REQUIRED FOR : M ti ,..-.... 0 Elect/kat Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. . NOTE: Revisions will require a new plan submittal' RECEIVED CITY OF TUKWILA JUN 2 9 2009 PERMIT CENTER and may include additional plan review fees. A Tenant Improvement for: SABEY 12201 TyKWILA INTERNATIONAL BLVD. SUITE 4�O SEATTLE, WA 98168 Tenant APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 burgess design I interiors � architecture 1326 Fifth Avow Suite 500 . Seittle . WA 88101 TEL: 206.587.7120 FAX:206. 587.7122 All reproduction & intellectual property rights reserved c 2009 FELE COPY Permit No. 12 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approve?F Copy :,.11 ,, -111?.111 - owledged: Professional seal By Date. 7A City Of lbktvila BUILDING D ION No. Issue Description REVIEW SET PERMIT SET 7196 REGISTERED ARCHITECT KIP G. KOLODZIEJSKI STATE OF WASHINGTON P D r r o a _w by: : M 0 K 9 /T s S B04_0 R o eviewed by: Date 6/22/09 - 6/25/09 KK COVER SHEET / PROJECT INFORMATION Original drawing is 30" x 42". Scale entities accordingly if reduced G.0 .0 PROJECT NOTES 1. THESE PROJECT NOTES ARE GENERIC IN NATURE. CONTRACTORS INSTRUCTIONS FOR CONSTRUCTION ADMINISTRATION MAY VARY BASED ON THE CONTRACT BETWEEN BUILDING MANAGEMENT AND TENANT. VERIFY WITH BUILDING MANAGEMENT ALL CONSTRUCTION REQUIREMENTS AND CONSTRUCTION ADMINISTRATION RESPONSIBILITIES. THE DESIGNER MAY NOT HAVE CONSTRUCTION ADMINISTRATION OBLIGATIONS. 2. PLUMBING, ELECTRICAL, MECHANICAL & LIFE SAFETY SHALL BE PERFORMED UNDER THE DESIGN /BUILD CONTRACT. ALL WORK SHALL BE TO CODE. ANY INFORMATION ON THESE DRAWINGS ARE FOR REFERENCE AND SCHEMATIC DESIGN ONLY. CONTRACTOR 1S RESPONSIBLE FOR ALL ASPECTS OF THE DESIGN. VERIFY REQUIREMENTS OF BUILDING MANAGEMENT AND TENANT. REVIEW OF SHOP DRAWINGS, IF APPROPRIATE, IS FOR AESTHETIC REASONS ONLY 3. VERIFY ALL RULES, GENERAL CONDMONS AND SPECIALIZED BUILDING REQUIREMENTS WITH THE BUILDING MANAGEMENT. 4. ALL WORK BY TENANT SHALL MEET SABEY TENANT CRITERIA MANUAL REQUIREMENTS: OMSION I - GENERAL CONDRIONS 01010 SUMMARY OF WORK 1. GENERAL DESCRIPTION OF THE PROJECT: NON- STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE, UON. 2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS "BUILDING STANDARD" ON THE PLANS, THE CONTRACTOR SHALL SO ADVISE BURGESS DESIGN WITHIN TEN (10) DAYS OF THE CONTRACTOR'S RECEIPT OF THE PLANS SO THAT BURGESS DESIGN MAY MAKE ALTERNATE SELECTIONS. 3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF. EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES, AND IS RESPONSIBLE FOR ALL ROUGH -IN CONNECTIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE 4. FIRE /EMERGENCY SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, SPRINKLER MODIFICATIONS, FIRE EXTINGUISHER PLACEMENT, AUDIBLE ALARMS, SMOKE AND HEAT DETECTORS, STROBES, AND EXIT SIGN PLACEMENT. 5. ALL DESIGN BUILD INFRASTRUCTURE SHALL BE UNDER A SEPARATE PERMIT BY CONTRACTOR. 6. WORK NOT INCLUDED: CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE SPECIFICATIONS AND SHOWN ON THE PLANS EXCEPT FOR THE ITEMS INDICATED "N.I.C." (NOT IN CONTRACT), SUCH AS TELEPHONE AND DATA CABLES, OFFICE FURNITURE, EQUIPMENT AND MOBILE KITCHEN APPLIANCES. 7. CONTRACTOR TO PROVIDE ALL FIRE /EMERGENCY SYSTEMS AS REQUIRED BY ALL APPUCABLE CODES. FIRE /EMERGENCY SYSTEMS INCLUDE BUT NOT LIMITED TO SPRINKLER MODIFICATIONS, FIRE EXTINGUISHERS, AUDIBLE ALARMS, STROBES, SPRINKLERS, SMOKE AND HEAT DETECTORS, AND EXIT SIGNS. 8. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED. 9. ANY MATERIAL USED IN CONSTRUCTION . SHALL MEET CURRENT FLAME CODE REGULATIONS. 10. ALL ELECTRICAL PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHALL COMPLY WITH THE BUILDING SHELL STANDARD SPECIFICATIONS. 11. THE GENERAL CONTRACTOR SHALL LAY OUT THE WORK IN CONFORMITY WITH THE REQUIREMENTS OF CONTRACT DOCUMENTS, AND WILL BE HELD RESPONSIBLE FOR PROPER ESTABLISHMENT AND MAINTENANCE OF ALL LINES AND DIMENSIONS. BEFORE DOING AND WORK, THE GENERAL CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AND CONDMONS AT THE SITE AND NOTIFY THE ARCHITECTS OF ANY DISCREPANCIES. 12. THE CONTRACTORS SHALL USE DIMENSIONS ONLY. DO NOT SCALE. PLANS. ALL DIMENSIONS ARE TO FINISHED FACE UNLESS OTHERWISE NOTED. 13. MATERIALS: ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY MANUFACTURERS. ALL LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURER AND QUALITY UNLESS OTHERWISE SPECIFIED. ALL MATERIAL EQUIPMENT AND FIXTURES SHALL BE CODE WORTHY WITH ALL PROPER JURISDICTIONAL APPROVALS. DMSION II SITE WORK 02050 - DEMOLITION 1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOUT1ON AND REMOVAL OF ALL ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF ALL DEMOLITION WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN. 2. DEMOLITION OF TELEPHONES, ELECTRICAL VOICE /DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED CABLING TO BE REMOVED FROM TENANT SPACES BELOW. 1 DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. 4. ALL DOSING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION NEGOTIATED BY THE PRICING PLAN / SPACE PLAN WITH WORK LETTER SHALL BE REMOVED, RELOCATED, OR KEPT FLUSH IN CEIUNG, WALL,; OR FLOOR AS REQUIRED. 5. ALL DAMAGED, ALTERED OR REWORKED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH ". 6. ` CONTRACTOR SHALL PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUST AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. DMSION VI - ARCHITECTURAL CARPENTRY AND CASEWORK 06100 - ROUGH CARPENTRY 1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS, BUCKS, NAILERS, BACKING, FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. AS DETAILED. 06200 - FINISH CARPENTRY 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED. 06400 - ARCHITECTURAL WOODWORK AND CASEWORK 1. CABINET CONSTRUCTION: COMPLY WITH THE A.W.I. ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR CUSTOM GRADE WORK. CABINETS SHALL BE FLUSH CONSTRUCTION. 2. PROVIDE PARTICLE BOARD, MED. DENSITY, WEIGHING <40 LB. /CU. FT, AT LEAST 3/4" THICK. 3. CABINET HARDWARE: FULL EXTENSION DRAWER GLIDES, STAINLESS STEEL CABINET PULLS, US32D FINISH, AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, UON IN ELEVATIONS / DETAILS, OR PER BUILDING STANDARD. 4. PLASTIC LAMINATE HIGH- PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, AND FORMICA, UON. LAMINATE TO BE GENERAL - PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL 5. INTERIOR CABINET SURFACES AND SHELVES TO BE OF PREFINISHED BOARD WITH POLYESTER OVERLAY, UON. 6. SHELF EDGING TO BE VINYL UON. 7. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. DMSION VIII DOORS AND WINDOWS 08210 - WOOD DOORS 1. PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS. 2. DOOR SCHEDULE SPECIFIES FINISH (BOTH SIDES OF DOOR) AND FRAME, UON. 3. DOORS SHALL BE PRE - MACHINED FOR HARDWARE PER HARDWARE SCHEDULE. 4. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 5. CONTRACTOR SHALL REVIEW SUITE FOR DOOR STYLE CHANGES AND VERIFY WITH ARCHITECT AND BUILDING MANAGEMENT THE DOOR STYLE TO MATCH IF A VARIATION IS PRESENT. 08710 FINISH HARDWARE 1. FINISH AND SPECIALTY HARDWARE INCLUDES ALL ACCESSORIES, TOOLS, AND FASTENERS REQUIRED FOR HARDWARE INSTALLATION AND MAINTENANCE. ITEMS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO COMPLETE THE WORK, SHALL BE FURNISHED MATCHING IN QUALITY AND FINISH OF SPECIFIED IN SIMILAR LOCATIONS. 2. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDULE. 3. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE TWO (2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. ALL KEYS TO BE TAGGED WITH ROOM NUMBERS. CONFIRM QUANTITY WITH BUILDING MANAGEMENT. 4. SUBMIT HARDWARE SCHEDULE WITH CATALOGUE CUT SHEETS FOR ARCHITECT REVIEW. 5. ALL DOORS SHALL HAVE A MINIMUM OF 1 -1/2 PAIR OF BUTT HINGES, ONE LATCHSET OR LOCK SET, AND ONE DOOR STOP TO MEET ACCESSIBILITY REQUIREMENTS. 6. ALL HARDWARE SHALL BE COMMERCIAL GRADE AND RATED AT REQUIRED ASSEMBLIES. 7. PROVIDE CLOSERS PER HARDWARE SCHEDULE AND AT ALL RATED ASSEMBLIES. 8. ALL HARDWARE SHALL MATCH BUILDING STANDARD IN STYLE AND FINISH. 9. SET UNITS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND OPERATION. 10. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERY UNIT. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE APPLICATION MADE. 11. PROVIDE PROPER SMOKE GASKETS AT RATED ASSEMBLIES. 12. MATCH BUILDING STANDARD SPECIFICATIONS AND FINISHES. 08810 GLASS 1. ALL GLASS AT SIDELIGHTS AND DOORS SHALL BE 1/4" TEMPERED SAFETY GLAZING, UON. 2. CONTRACTOR SHALL VERIFY GLASS THICKNESS IS APPROPRIATE FOR DIMENSIONS AND SPANS. 3. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS. GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS. ' IF GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARD, THEY SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 4. RATED GLASS (CERAMIC) RELITE SHALL BE PREMIUM POLISHED FINISH. DMSION IX FINISHES 09250 GYPSUM DRYWALL AND METAL STUDS 1. INCLUDE NECESSARY MATERIALS, LABOR AND. ACCESSORIES FOR THE INSTALLATION OF ALL PARTMONS AS SHOWN IN THE PLANS. 2. "WALL SURFACES" MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC. 3. ALL PARTITION HEADS SHALL MATCH BUILDING STANDARD, UON. 4. WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE BUILDING STRUCTURE, UON. 5. SEISMIC. BRACING: PROVIDE : SEISMIC BRACING AS REQUIRED PER THE LATEST BUILDING CODES TO THE PARTITION HEADS AND CEILING GRID. 6. FRAMING STUDS: GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE WITH SHEET METAL BACKING WITHIN ALL WALLS RECEMNG CASEWORK (CABINETS, BOOKSHELVES, ETC.). VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCK IF APPLICABLE. 7. CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING, AND ELECTRICAL WORK. FIRE RATE AS REQUIRED. 8. ALL DRYWALL TO BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED. PROVIDE "M /R" TYPE DRYWALL WHERE REQUIRED BY CODE AND AT ALL TOILET ROOMS, AND BEHIND CERAMIC TILES, UON. 9. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS. INSTALL METAL EDGE TRIM WHENEVER EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI- EXPOSED. 10. PRIOR TO RECEIVING FINISH, ALL SURFACES SHALL BE PROPERLY PREPARED AS REQUIRED TO RECEIVE FINAL FINISHING AS SPECIFIED. 11. EXTEND ALL SOFFIT FRAMING TO STRUCTURE ABOVE PROVIDE STRUCTURAL DIAGONAL BRACING AS NECESSARY. 12. PROVIDE FRAMING FOR SUSPENDED CEILING WITH SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AND AS SHOWN ON DRAWINGS. 13. USE ACOUSTICAL: SEALANT AROUND ALL PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES ETC. ON BOTH SIDES OF CROSSING /PENETRATING WALLS WITH ACOUSTICAL INSULATION. PENETRATIONS OF FIRE -RATED WALLS SHALL BE PROTECTED BY APPLICABLE FIRE -RATED ASSEMBLIES AND MATERIALS. 09500 - CEILING SUSPENSION SYSTEMS. 1. PROVIDE NEW CEILING TILE, CEILING GRID AND ALL ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEILINGS AS INDICATED ON DRAWINGS. 2. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. VERIFY WITH BUILDING MANAGEMENT IF EXISTING CONDITIONS ARE SEISMICALLY BRACED OR PROVIDE PER CODE. 3. COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEIUNG AND THE TELEPHONE AND DATA CABLE COMPANIES WHEREVER THEIR RESPECTIVE WORK IS CONTIGUOUS. 4. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES, REGISTERS, DIFFUSERS, SPRINKLERS, AND OTHER INSERTED ITEMS. 5. ALL CUTOUTS SHALL BE CENTERED WITHIN ACOUSTIC CEILING TILE, UON. 6. ALL MATERIALS SHALL HAVE CLASS 1 FLAME SPREAD RATING AND BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND CODES. 7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL AND PERFECTLY ALIGNED WITH EACH OTHER. 8. INSTALLED SUSPENDED CEILINGS TO BE LEVEL WITHIN A TOLERANCE OF 1/8" IN 12' -0 ". ANCHOR AS REQUIRED. 9. IN AREAS OF ALTERATIONS CONTRACTOR SHALL MATCH CONDITIONS AND MAKE EVERY EFFORT TO ALIGN, LEVEL AND MATCH NEW CEILING TO OLD. CONTRACTOR SHALL REVIEW ALL CEILINGS UPON COMMENCEMENT OF THE PROJECT AND INFORM. THE BUILDING. MANAGEMENT OF ANY DISCONTINUmES IN THE CEIUNG WITHIN 10 DAYS. 10. ADJUST PARTITION HEAD, DETAIL TO MATCH EXISTING CEIUNG CONDITIONS IF NECESSARY. 09530 - ACOUSTICAL TREATMENT 1. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF PARTITION HEAD ABOVE CEILINGS FOR ALL WALLS. NOTED PER PLANS. 2. NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND TWO FEET OF INSULATION ON EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID, UON. 09650 RESIUENT FLOORING 1. PROVIDE VCT, SHEET LINOLEUM, SHEET VINYL AND RUBBER BASE AS INDICATED IN DRAWINGS. COLOR AND MANUFACTURER PER FINISH SCHEDULE. 2. PROVIDE RUBBER - REDUCING STRIPS IN COLOR TO MATCH SPECIFIED BASE. REDUCING STRIPS TO OCCUR AT ALL AREAS OF FLOOR MATERIAL TRANSITION. 3. BASE TO BE INSTALLED IN LONGEST AVAILABLE LENGTH WITH NO PIECE LESS THAN 12 ". NO JOINTS AT OUTSIDE CORNERS OR WITHIN 6" OF CORNERS. 4. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITIOUS UNDERLAY PER MANUFACTURER'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10' 5. GENERAL CONTRACTOR SHALL APPLY FLOOR WAX TO NEW FLOORING AREAS PER MANUFACTURERS SPECIFICATION, UON. 09680 - CARPET 1. PROVIDE COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS. 2. CARPET TO BE INSTALLED AS INDICATED IN DRAWINGS. 3. PREPARE SUB FLOOR WITH LIGHT WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE. ` MAX. ALLOWABLE TOLERANCE 1/4" OVER 10'. 4. PROVIDE SEAMING DIAGRAMS FOR ARCHITECT'S REVIEW. 09900 - PAINTING AND STAIN 1. UNLESS OTHERWISE NOTED, PRIME ALL GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2) FINISH COATS OF BENJAMIN MOORE EGGSHELL FINISH LATEX PAINT OR APPROVED EQUAL UON. PROVIDE FOR NUMBER OF PAINT COLORS AS INDICATED IN DRAWINGS. 2. FINISH DOORS, DOOR FRAMES, AND SIDELIGHT FRAMES AS INDICATED IN DRAWINGS. A) PAINTED WOODWORK TO BE FINISHED WITH ONE (1) COAT PRIMER AND TWO (2) FINISH COATS. B) SEALED WOODWORK TO BE STAINED PER FINISH SCHEDULE AND SEALED WITH A COMMERCIAL GRADE CLEAR SATIN VARNISH. 3. PAINT FOR THE LIGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (2 COAT) GRADE UGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. 4. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (2 COAT) GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES. 5. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM ALL OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME 6. TOUCH -UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF WORK BY OTHER TRADES. 7. WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY SHALL RECEIVE THE SAME FINISH AS THE ROOM, UON. 8. ALL PAINTED SURFACES SHALL BE PREPARED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (ESPECIALLY IN REGARD TO THE PRIMING OF EXISTING SURFACES). 9. PUTTY ALL NAIL HOLES, COUNTERSUNK ` SCREWS, BOLTS, CRACKS, ETC. BEFORE APPLYING FINISH. 10. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. 11. SAND ENAMELED FINISHES APPLIED TO WOODS OR METAL BETWEEN COATS WITH FINE SANDPAPER TO PRODUCE SMOOTH FINISH. 12. MAKE FINISH WORK UNIFORM AND SMOOTH, FREE OF RUNS, SAGS, DEFECTIVE BRUSHING AND CLOGGING. MAKE EDGES - OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING. 12500 -' WINDOW TREATMENT 1. ALL EXISTING INTERIOR AND PERIMETER MINI BONDS TO BE BAGGED AND CLEANED TO LIKE -NEW CONDmON. 2. ALL PERIMETER GLAZING TO RECEIVE BLINDS AS INDICATED IN DRAWINGS. COORDINATE WITH BUILDING MANAGEMENT. MATCH EXISTING CONDITIONS UON. 4. PROVIDE SAMPLE AND CUT SHEET TO ARCHITECT FOR REVIEW. 3. ALL INTERIOR SIDELIGHTS TO RECEIVE 1" MINI -BONDS WHERE INDICATED IN DRAWINGS. DMSION XV MECHANICA 15400 ` PLUMBING 1. PROVIDE SUPPLY, WASTE AND VENT UNES, VALVES, FITTINGS, ETC. REQUIRED FOR KITCHEN SINKS, DISHWASHER, REFRIGERATOR, AIR CONDMONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER HEATERS, ETC. 2. ALL FIXTURE INSTALLATIONS SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE NEW PLUMBING FIXTURES AS SPECIFIED PER DRAWINGS, OR PER BUILDING STANDARD, UON. 4. PROVIDE HOT AND COLD WATER TO SINKS /DISHWASHERS IF APPLICABLE. 5. ALL NEW WATER HEATERS ARE TO BE INSTALLED WITH DRIP PAN CONNECTED TO WASTE LINE. VERIFY LOCATIONS WITH BUILDING MANAGEMENT AND INSPECTORS. 6. ALL PLUMBING FIXTURES ARE TO BE INSTALLED TO MEET CURRENT GOVERNING LOCAL AND FEDERAL CODES. 7. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 15500 FIRE PROTECTION 1. ALTER OR INSTALL FIRE PROTECTION SYSTEM PER BUILDING STANDARD, LOCAL REGULATIONS AND ORDINANCES. 2. PROVIDE ALL EMERGENCY UGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BR I S AS REQUIRED BY CODE. DESIGN AND INSTALL THE SAME IN COMPUANCE WITH THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE SPRINKLERS, FIRE RATED DOORS AND FRAMES, FIRE EXTINGUISHERS, ETC. AS REQUIRED BY APPLICABLE LOCAL CODES AND LAWS. 4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITER'S LABORATORY 2A -10BC 5 -LB, MULTIPURPOSE EXTINGUISHER WITH SQUEEZE -TYPE HANDLE AND FLEXIBLE DISCHARGE HOSE WITH ' VISIBLE PRESSURE GAUGE, UON. 5. FIRE EXTINGUISHERS SHALL BE INSTALLED PER BUILDING STANDARD REQUIREMENTS, UON. VERIFY LOCATION WITH FIRE MARSHALL 6. DESIGN BUILD FIRE PROTECTION DRAWINGS INDICATE: A. LAYOUT, LOCATION, AND SIZE OF SPRINKLER UNES AND HEADS. 8. PRESSURE REQUIREMENTS. C. SPRINKLER HEAD SPECIFICATIONS. D. LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS 7. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE HORNS AND STROBES. 8. ALL SPRINKLER HEADS SHALL BE CENTERED IN ACOUSTICAL CEILING TILE, UON. 9. USE OF NFPA 13 QUICK RESPONSE HEADS MAY BE REQUIRED. CONTRACTOR SHALL VERIFY EXTENT OF QUICK RESPONSE HEADS BY CITY FOR THIS PROJECT. 15800 HEATING VENTILATING AND AIR CONDITIONING 1. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH ALL MATERIALS, LABOR AND ACCESSORIES FOR COMPLETE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE HVAC SYSTEM AS REQUIRED. 2. DESIGN BUILD MECHANICAL ENGINEERING DRAWINGS INDICATE: A. DUCTS, AIR MOVEMENT REQUIREMENTS, & SIZES OF GRILLES & REGISTERS. 3. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER. FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 4. HVAC CONTRACTOR TO CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS, FILTERS AND THERMOSTATS. 5. RE -ZONE, ALTER OR SEPARATE HVAC AS NECESSARY AS DIRECTED BY BUILDING MANAGEMENT FOR ALTERED SUITES. 16000 - ELECTRICAL AND TELECOMMUNICATIONS 1. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. REPLACE OUTLET COVER PLATES TO MATCH NEW FINISH IF APPLICABLE. 2. PROVIDE ALL WORK, EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL SYSTEM. PROVIDE ELECTRICAL OUTLETS PER POWER AND DATA PLAN. 3. PROVIDE MUD RING FOR DATA AND COMMUNICATION AS SHOWN ON THE POWER AND DATA PLAN. EACH MUD RING TO HAVE A MINIMUM NUMBER OF WIRE PULLS AS INDICATED ON DRAWINGS. COORDINATE DATA CABLE CONFIGURATION WITH THE TENANT. 4. ALL OUTLETS AND MUD RINGS TO BE LOCATED AT 18" AFF TO THE CENTER LINE, UON. 5. WHERE MULTIPLE DEVISES OCCUR IN A SINGLE LOCATION, ALL DEVICES SHALL BE GANGED UON. 6. ALL ELECTRICAL OUTLETS WITHIN THE CODE REQUIRED DISTANCE FROM A SINK SHALL BE ON A GROUND FAULT INTERRUPTED CIRCUIT. 7.' ALL WIRING DEVICES: SHALL BE BUILDING STANDARD EXCEPT: "ISOLATED GROUND" OUTLETS SHALL BE ORANGE, "HOSPITAL GRADE ISOLATED GROUND" OUTLETS SHALL BE ORANGE. WITH A GREEN DOT, "EMERGENCY" OUTLETS SHALL ` BE RED, AND "DEDICATED" OUTLETS FOR "CLEAN CIRCUIT" FIXTURES SHALL BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). ALL COVER PLATES SHALL BE BUILDING STANDARD FINISH, UON. VERIFY, WITH BUILDING MANAGEMENT. 8. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING THE TELEPHONE SWITCH, COPIERS, COMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION DOCUMENTS. 9. COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE INSTALLATION OF TENANT'S NEW FURNITURE. 10. ALL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABUNG, AND CONDUIT SHALL BE CONCEALED IN FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA TO BE PROVIDED BY TENANT'S VENDORS AND SHALL BE COORDINATED BY THE BUILDING MANAGER. 11. THE CONTRACTOR IS TO COORDINATE WITH THE OWNER SUPPUED FURNITURE SYSTEMS TO INCLUDE BUT NOT LIMITED TO: ELECTRICAL AND DATA WIRING LOCATIONS, J -BOX LOCATIONS, CONNECTIONS AND WALL MOUNTED REQUIREMENTS. 12. THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH' MATERIAL TO MEET CURRENT FLAME SPREAD REGULATIONS. LOCATIONS TO BE PREPARED TO RECEIVE NEW FLOOR FINISH AS REQUIRED. FLOOR SHALL BE LEFT FLUSH. 13. ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY OF DEVICES SHOWN. SWITCHING AND CIRCUTING SHALL BE INDICATED ON SEPARATE ELECTRICAL ENGINEERING AS -BUILT DRAWINGS AND SHALL MEET OWNER'S GUIDELINES. 14. ALL TELEPHONE, ELECTRICAL, COMMUNICATION AND SECURITY WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL. APPLICABLE CODES. 15. DRAWINGS INDICATE ALL DIMENSIONS TO CENTERLINE OF TELEPHONE, ELECTRICAL AND COMMUNICATION COVER PLATE. - OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION BETWEEN EACH DEVICE. 16. BACK -TO -BACK OUTLETS ARE NOT PERMITTED. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED FOR ACOUSTICAL CONTROL 17. LOCATION OF ALL WALL MOUNTED POWER AND DATA DEVICES SHALL BE FIELD REVIEWED BY THE TENANT BEFORE INSTALLATION. 18. ELECTRICAL ENGINEER TO PROVIDE DESIGN /BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. 19. THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER & DATA DEVICES. REFER TO DESIGN /BUILD DOCUMENTS FOR SCOPE, TECHNICAL LAYOUT AND SPECIFICATIONS FOR EACH DISCIPLINE. 20. ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES. COORDINATE EXACT LOCATION WITH FURNITURE VENDOR. 21. COORDINATE POWER /DATA, FIRE SAFETY DEVICES & LIGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR ELEVATIONS, SYSTEM FURNITURE, FINISHES & CASEWORK. 22. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER /DATA DEVICES AND LIGHT FIXTURES. COORDINATE WITH INTERIOR FINISHES AND CASEWORK. 23. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE GRILLS AND THERMOSTATS. 24. RECIRCUIT, ALTER OR SEPARATE ELECTRICAL AND VOICE SYSTEM AS NECESSARY AND AS DIRECTED BY BUILDING MANAGEMENT FOR ALTERED SUITES. 16500 LIGHTING 1. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED CEIUNG PLAN. ALL SWITCHES SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 48" A.F.F. TO MEET THE LATEST ACCESSIBIUTY CODES AND REGULATIONS. 2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION, ALL SWITCHES SHALL BE GANGED UON. 3. DOWN LIGHTS SHOWN IN THE CENTER OF CEIUNG TILE WITHOUT DIMENSIONS ARE TO BE LOCATED IN THE CENTER OF CEIUNG TILE, UON. 4. REUSE ALL EXISTING BUILDING STANDARD FLUORESCENT FIXTURES AS NEEDED PER DESIGN LAYOUT AND TO MEET LOCAL ENERGY CODE COMPUANCE. VERIFY OR PROVIDE NEW LAMPS AND REPLACE FAULTY BALLASTS. 5. PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD PRIOR TO COMMENCEMENT OF WORK. 6. ALL OFFICE AREAS LESS THAN 300 SQ. FT. ENCLOSED BY WALLS OR CEIUNG- HEIGHT PARTITIONS, AND ALL MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS, PER CODE. 7 DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS INDICATE: A. CIRCUITING AND WIRING OF LIGHT FIXTURES, AND SWITCHES. B. UFE SAFETY EQUIPMENT. C. LOCATION OF REQUIRED EMERGENCY UGHT FIXTURES. D. ' UGHT FIXTURE SPECIFICATIONS 8. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 9. CONTRACTOR SHALL RE- CIRCUIT AND RE- SWITCH ALL ASPECTS OF TENANT SUITE AND ADJOINING SUITES AS NECESSARY TO FULLY SEPARATE TENANT SUITE FROM OTHERS, AND PROVIDE NEW CORRIDOR, HALLWAY AND OPEN OFFICE SWITCHES AS NEEDED. 10. VERIFY SWITCHING WITH TENANT AND BUILDING MANAGEMENT. VERIFY APPROVED ENERGY CODE REQUIREMENTS OR ENERGY MANAGEMENT SYSTEM AS PART OF THE DESIGN BUILD CONTRACT PROVIDE, ALTER OR VERIFY ALL EMERGENCY EXIT LIGHTING AND ACCESS PATHWAY UGHTING AS DIRECTED BY EXISTING CONDMONS AND CODE REQUIREMENTS. A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD.. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 burgess design) interiors O architecture 1326 Fifth Avrnuc Suitc 500. Sr ttic . WA 98101 TEL: 206.587.7120 FAX:206. 587.7122 All reproduction Sc intellectual property rights reserved c 2009 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2009 City of Tukwila BUILDING DIVISION Professional seal No. Issue Description REVIEW SET PERMIT SET Drawn by: MK /TS 7196 Project No: 09- SB04 -00 Reviewed by: PROJECT NOTES REGISTERED ARCHITECT KIP G. KOLCDZfEJSKI STATE OF WASHINGTON RECEIVED CITY OF TUKWILA JUN 2 9 LUUy PERMIT CENTER G.0.1 Date 6/22/09 6/25/09 KK Original drawing is 30" x 42 ". Scale entities accordingly if reduced FUTURE NORTHWIND WEIR PARK REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2009 A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 1326 Fifth Avenue Suite 500. Se tree . WA 99101 TEL: 208.587.7120 FAX:206. 587.7122 All reproduction & intellectual property rights reserved c 2009 Professional seal 7196 No. Issue Description REVIEW SET PERMIT SET REGISTERED ARCHITECT K? 0. ItOLODZIEJSKI STATE OF WASHINGTON Reviewed by: RECEIVED CITY OF TUKWILA JUN 292009 PERMIT CENTER 6/22/09 6/25/09 Original drawing is 30" x 42 ". Scale entities accordingly if reduced FaraliMai 0 . ,... .. ,,,, ....................... REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 7 2009 SYMBOL - EGRESS PATHWAY FOR EMERGENCY LIGHTS. DESIGN BUILD CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTS, PER 1006. VERIFY PATHWAY WITH FINAL FURNITURE LAYOUT. GENERAL 1. THIS TENANT IMPROVEMENT TO BE PERMITTED AS MIXED OCCUPANTS WITH UNSEPARATED USES PER IBC SECTION 302.1 THE ORIGINAL BUILDING WAS PERMITTED WAS A V-N FIRE SPRINKLERED BUILDING IN 1987 WITH UNLIMITED AREA WITH 60' YARDS ON ALL SIDES. WE PROPOSE TO CHANGE THE BUILDING CLASSIFICATION, BASED ON 2003 UBC, TO CONSTRUCTION TYPE VB FIRE SPRINKLER WITH UNLIMITED AREA PER SECTION 507.3 "TWO STORY." THE AREAS OF A TWO STORY GROUP B, F, M OR S BUILDING SHALL NOT BE LIMITED WHEN THE BUILDING IS PROVIDED WITH AN AUTOMATIC SPRINKLERS SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 THROUGHOUT AND IS SURROUNDED AND ADJOINED BY PUBLIC WAYS OR YARDS NOT LESS 'THEN 60 FEET IN WIDTH. . EXITS ARE GREATER THAN 1/3 DISTANCE OF DIAGONAL (1015.2.1 X 2 A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 1326 Fifth Avenue Suite SOO . ScIttle . WA 98101 TEL 206.587.7120 FAX:206. 587.7122 All reproduction & intellectual property rights reserved c 2009 Professional seal REVIEW SET PERMIT SET Drawn by: MK/TS MP G. KOLGDMEJSM STATE Of WASHINGTON Original drawing is 30" x 42". Scale entities accordingly if reduced .■:: .....'... — "'..e..1.t-13.: , . >2..".:,-.. .....7„.,, ,:. - ' '" ' ' .." ' ' '. '4.}- ' ' ' ,',-,-• ;15.*MIL j 1 1 1 1 1 1 ,,,,, 1 ,. ...fri.i ,.., • 't I 7:4MT.' vr ...',. ..4 ;• 11.• ",..41-9 ' ,..> .; '" r.. .'-...'" FaraliMai 0 . ,... .. ,,,, ....................... REVIEWED FOR CODE COMPLIANCE APPROVED JUL 1 7 2009 SYMBOL - EGRESS PATHWAY FOR EMERGENCY LIGHTS. DESIGN BUILD CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTS, PER 1006. VERIFY PATHWAY WITH FINAL FURNITURE LAYOUT. GENERAL 1. THIS TENANT IMPROVEMENT TO BE PERMITTED AS MIXED OCCUPANTS WITH UNSEPARATED USES PER IBC SECTION 302.1 THE ORIGINAL BUILDING WAS PERMITTED WAS A V-N FIRE SPRINKLERED BUILDING IN 1987 WITH UNLIMITED AREA WITH 60' YARDS ON ALL SIDES. WE PROPOSE TO CHANGE THE BUILDING CLASSIFICATION, BASED ON 2003 UBC, TO CONSTRUCTION TYPE VB FIRE SPRINKLER WITH UNLIMITED AREA PER SECTION 507.3 "TWO STORY." THE AREAS OF A TWO STORY GROUP B, F, M OR S BUILDING SHALL NOT BE LIMITED WHEN THE BUILDING IS PROVIDED WITH AN AUTOMATIC SPRINKLERS SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 THROUGHOUT AND IS SURROUNDED AND ADJOINED BY PUBLIC WAYS OR YARDS NOT LESS 'THEN 60 FEET IN WIDTH. . EXITS ARE GREATER THAN 1/3 DISTANCE OF DIAGONAL (1015.2.1 X 2 A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 1326 Fifth Avenue Suite SOO . ScIttle . WA 98101 TEL 206.587.7120 FAX:206. 587.7122 All reproduction & intellectual property rights reserved c 2009 Professional seal REVIEW SET PERMIT SET Drawn by: MK/TS MP G. KOLGDMEJSM STATE Of WASHINGTON Original drawing is 30" x 42". Scale entities accordingly if reduced REVIEWED FOR CODE COMPLIANCE APPROVE JUL 17 2009 City of Tukwila BUILDING DIVISION EXISTING CONSTRUCTION TO BE REMOVED EXISTING CONSTRUCTION TO REMAIN REFER TO CONSTRUCTION PLAN, CEILING PLAN, ELECTRICAL PLAN AND FINISH PLAN FOR EXTENT OF DEMOLITION. . SAVE AND STORE ALL LIGHT FIXTURES, EXIT SIGNS, DOORS & HARDWARE FOR RE -USE, UON. SAVE ALL EXISTING PLUMBING FIXTURES FOR RE -USE, UNLESS OTHERWISE NOTED. . REMOVE ALL TELEPHONE, ELECTRICAL, AND DATA OUTL.ErS, FIXTURES, PANELS, ETC FROM ALL DEMOLISHED PARTITIONS. REMOVE ALL CORRESPONDING CABLES, CONDUIT, WIRING, ETC. ALL THE WAY BACK TO THE ORIGINATING SOURCE, UON. DEMO DOOR, FRAME, AND HARDWARE. - TO BE STORED OR RELOCATED AND REINSTALLED WHERE APPLICABLE. VERIFY WITH BUILDING MANAGEMENT. DEMO REUTE AND FRAME- TO BE STORED OR RELOCATED AND REINSTALLED WHERE APPLICABLE VERIFY WITH BUILDING MANAGEMENT. REMOVE EXISTING FULL HEIGHT WHITE BOARDS. PATCH AND REPAIR WALL AS REQUIRED FOR NEW FINISHES. DEMO EXISTING WALL PANELS TO BE REMOVED. PATCH AND REPAIR WALL AS REQUIRED FOR INSTALLATION NEW WALL PANELS. U DEMO EXISTING COUNTERTOP. COORDINATE STORAGE AND REINSTALLATION, IF APPLICABLE, WM-I BUILDING MANAGEMENT. PATCH AND REPAIR WALL AS REQUIRED FOR NEW FINISHES. O DEMO EXISTING BASE AND UPPER CASEWORK WHERE APPLICABLE. TO BE STORED AND REINSTALLED WHERE APPLICABLE, VERIFY WITH BUILDING MANAGEMENT. PATCH AND REPAIR WALL AS REQUIRED FOR NEW FINISH. O7 DEMO EXISTING PASSTHRU DOORS AND FRAME PATCH AND REPAIR WALL AS REQUIRED FOR NEW FINISH. SO REMOVE AND RELOCATE EXISTING FIRE EXTINGUISHER. DEMO EXISTING COMPUTER /SERVER RACKING. VERIFY EXTENT OF REMOVAL OF ASSOCIATED WIRING AND HARDWARE WITH TENANT AND BUILDING MANAGEMENT. PATCH AND R EPAIR FLOORING AS REQUIRED AFTER REMOVAL SEE KEYNOTES ON A.2C.1 FOR MORE INFORMATION. 10 ABANDON EXISTING CORE DRILLS. 11 CONTRACTOR SHALL CAREFULLY MEASURE EXISTING DECORATIVE WOOD PANELS BEFORE DEMOLI11ON. CONSTRUCTION OF NEW PANEL WILL MATCH THESE EXISTING PANELS. A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 Issue Description KIP G. KOLODZIE.ISK9 STATE OF WASHINGTON REGISTERED ARCHITECT Original drawing is 30" x 42 ". Scale entities accordingly if reduced burgess design I interiors 0 architecture 1326 Fifth Avenue Suite 500. Scittic . WA 98101 TEL: 206.587.7120 FAX:206. 587.7122 All reproduction & intellectual property rights reserved c 2009 CATERING REVIEWED FOR CODE COMPLIANCE APPROVED JUL 17 2009 NEW CASEWORK / MILLWORK LINE OF UPPER CABINETS NEW OR RELOCATED FIRE EXTINGUISHER CABINET AND DEVICE EXISTING CONSTRUCTION TO REMAIN NEW INSULATED INTERIOR PARTITION CONSTRUCTION, PER DETAIL S /A.9.1 REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. GENERAL CONTRACTOR TO FIELD VERIFY All EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. ALL INTERIOR PARTITION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PARTITION RATINGS. WHERE PARTITION LAYOUT INTERSECTS EXISTING SHELL /CORE GYPSUM BOARD, REMOVE EXISi1NG CORNER BEADS AND OTHER ACCESSORIES, ALIGN ` FACE OF PARTITIONS, TAPE & SAND SMOOTH FOR NEW FINISH. PROVIDE PART1ON ANCHOR BRACKETS FOR ALL CASEWORK, FIXTURES, EQUIPMENT, & DEVICES MOUNTED ON OR ATTACHED TO PARTITIONS. PARTITIONS ARE TO BE BUILDING STANDARD FLOOR TO CEILING PARTITIONS, UON. SEE TYPICAL WALL DETAIL SHEET FOR MORE INFORMATION. DOORS AND CASED OPENINGS WITHOUT DIMENSIONS OR. DETAILS ARE TO BE LOCATED 4" FROM ADJACENT WALL OR MATCH EXISTING SUITE STANDARD. ALL TENANT SIGNAGE BY TENANT. GENERAL CONTRACTOR SHALL PROVIDE BLOCING FOR A/V SCREENS AS REQUIRED ON ALL NEW WALLS. SEE TENANT'S A/V VENDER FOR LOCATIONS. ON EXISTING WALLS, VERIFY BLOCKING NEEDED WITH A/V VENDER. GENERAL CONTRACTOR TO PROVIDE BRACKETS. KEYED SHEET NOTES MODIFY CASEWORK AS REQUIRED FOR (2) NEW DISHWASHERS AND PROVIDE FINISHED END PANELS TO MATCH EXISTING P —LAM. DRAINAGE LINES CAN BE SURFACE MOUNTED TO PARTITION AND PAINTED. REPLACE EXISTING RECITE AND TRANSOM GLASS WITH NEW INSULATED GLASS WITH 3M FILM. PROVIDE NEW CHERRY WOOD VENEER PANELS IN PLACE OF EXISTING DECORATIVE PANELS ON THIS WALL ACOUSTICAL BATT INSULATION FULL HEIGHT. PROVIDE ACOUSTICAL SEALANT BOTH SIDES OF WALL AT BASE. PROVIDE ACOUSTICAL TAPE AT WALL HEAD. AND (2) SHELVES HIGH. TOP ALIGNS WITH EXISTING. PROVIDE A 28" DEEP, PL—X WORK SURFACE AT 29" A.F.F. WITH SUPPORTS A MINIMUM OF EVERY 24 ". SEE DETAIL F /A.9.1 FOR MORE INFORMATION. PROVIDE A 18' DEEP PL—X COUNTER AT 42 A.F.F. WITH SUPPORTS A MINIMUM OF EVERY 24 ". SEE DETAIL F /A.9.1 FOR MORE INFORMATION. PROVIDE (2) 8' WIDE WHITE BOARDS. VERIFY LOCATION WITH TENANT. VERIFY LENGTH OF NICHE WITH FINAL FILE CABINET FURNITURE PURCHASE. NEW WD -1 BOOKCASE TO RUN ALONG BACK OF RECEPTION AREA. BOOKCASE IS CURVED AND 6' -O' LONG CONTRACTOR SHALL CUT CEILING AND PROVIDE EXTENSION OF PARTITION UP TO STRUCTURE ABOVE. NEW CAVITY AND VERIFY OR PROVIDE INSULATION AT EXISTING PARITITON. 12> PROVIDE INSULATION IN PARTITIONS AND ABOVE PARTI1IONS 1N THIS OFFICE. 13 PROVIDE A 24" DEEP WD -1 WORK SURFACE AT 29' A.F.F. WITH SUPPORTS A MINIMUM OF EVERY 24' AND WD -1 SIDE PANEL SEE DETAIL F /A.9.1 FOR MORE INFORMATION. 14 INSULATE THIS PARTITION. 15 PROVIDE NEW 24 DEEP PL—X WORK SURFACE WITH SUPPORTS AT A MINIMUM OF EVERY 24 ". SEE DETAIL F /A.9.1. • PROVIDE NEW CASEWORK, TOPS AND VERTICAL SURFACES IN WD -1 FINISH. MATCH STYLE OF CABINETS NEAR BY. INSIDE TO BE FINISHED WITH GREY PLASTIC LAMINATE VERIFY SIZE OF UNDER COUNTER REFRIGERATOR WITH FINAL APPLIANCE PURCHASE. A Tenant Improvement for SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 burgess design! interiors Q architecture 1129 Fifth Avenue Suite 500. St ttic . WA 99101 TEL: 209.597.7120 FAX:205. Sti 7.7122 M reproduction & intellectual property rights reserved c 2009 KIP G. KOL CDZIEJSKI STATE OF WASHINGTON Original drawing is 30" x 42 ". Scale entities accordingly if reduced CEILING LEGEND - LIGHTING GENERAL GENERAL RCP SHEET NOTES KEYED S' SHEET NOTES LIGHTING SUMMARY SYMBOL DESCRIPTION SPEC DESCRIPTION/ SPEC ® EXISTING RECESSED CAN LIGHT REMAIN. 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. Q 2. ARCHITECTURAL REFLECTED C EF1E TED FILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN - BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEILING PLAN DESIGN. LIGHT SWITCHES ARE SHOWN FOR LOCATION AND ONLY. REFER TO ELECTRICAL DESIGN BUILD DESIGN INTENT ONLY FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. 4. UNLESS NOTED OTHERWISE, MULTIPLE SWITCH'S IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX � AND COVERED WITH A SINGLE COVERPLATE. 5. ALL IXiS11NG SUSPENDED CEILING. GRID AND .TILES EXISTING TO REMAIN.: CLEAN, REPAIR OR REPLACE AS REQUIRED. Q 6. MC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY RETURN GRILLS PRIOR TO COMPLETION / R PLET! N OF PROJECT. 7. ELECTRICAL SUB-CONTRACTOR NTRACTOR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES TO BE _ RELOCATED. 8 . ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR PROVIDING CUT SHEETS TO DESIGNER FOR ALL FIXTURES DESIGNATED AS NEW. 9. EMERGENCY LIGHTING WILL BE ON BATTERY BACK-UP. 10. GENERAL CONTRACTOR SHALL REPLACE DAMAGED TILES AS NEEDED. 11. SEE ELECTRICAL PLAN (A.2C.1) FOR ADDITIONAL ELECTRICAL AND VOICE /DATA IN CEILING. - G 1 EXISTING PENDANT LIGHT TO BE MODIFIED TO HIGHEST CEILING MOUNTED. HEIGHT POSSIBLE. " D 2 NEW RECESSED PROJECTION SCREEN. INSTALL. Q O CONTRACTOR TO PROVIDE BLOCKING AS REQUIRED, SUPPLY AND INSTAL VERIFY FINAL LOCATION WiTH TENANT. 3 NEW CEILING MOUNTED POWER DATA OUTLET FOR NETWORK PROJECTOR. VERIFY / ETW RK ROJE VER ELECTRICAL /DATA REQUIREMENTS WITH TENANT. FINAL LOCA TO BE VERIFIED WITH TENANT. 4 EXECUTIVE AREA TO FLUSH SPRINKLER HEADS. O UPGRADE SPRINKLERS IN EXECUTIVE 5 O NO CHANGES TO LIGHTING IN THIS ROOM. A NEW SCREENS BY TENANT. SEE A fi PLANS BY TENANT VENDOR. GC TO PROVIDE POWER, DATA AND. A/V � SWITCHING AT THESE LOCATIONS. 7 CEILING MOUNTED .. . LOCATION WfIH O PROJECTION SCREEN. GENERAL CONTRACTOR TO PROVIDE BRACKETS VERIFY TENANT. SEE A.2C.1 FOR .OTHER REQUIREMENTS. Q ° n 2006 Energy Code Compliance 9Y !lance Form P LIGHTING SUMMARY LTG -SUM i 771 I G _ _I EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE REMOVED. L EXISTING RECESSED CAN LIGHT TO BE REMOVED. 2008 �. N NEW 2' X 4' THREE LAMP. _ LAY IN PARABOLIC FLUORESCENT FIXTURE W/ T -8 LAMP. / ® - EXISTING RECESSED WALL WASHER TO REMAIN. Proj ect Info Project Address: RNERPOINT TEC HNICAL CENTER Date 6/22/09 2811 S. 102ND STREET For eaarling Department use = N NEW TUKWILLA, WA 98168 B �N = N NEW 4' NEW 2' X 4 DIRECT /INDIRECT, FLUORESCENT FIXTURE, UTHONIA AV T 8. D � N WALL.. EXISTING RECESSED WASHER TO BE REMOVED . Applicant Nam App BURGESS DESIGN INC. Applicant Addre 13 6 U � 2 5TH AVE, SUITE 500 SEATTLE WA 98101 EXISTING EXIT SIGN TO REMAIN. COORDINATE WITH CODE OFFICIAL EXISTING EXIT SIGN TO BE REMOVED Applicant Phone: 206.587.7120 App Project Descript Rew taw' � Add;tiaa ® A1talatk.r � s+s Compliance Option p p D ® lighting Power Allowance 0 Systems Analysis (see a1da7� (xladl&at (over). Indicate des �"° � SPA �°`°' `� on °) / R s� = _ N NEW = R RELOCATED NEW OR RELOCATED EXIT SIGN. COORDINATE FINAL LOCATION WITH CODE OFFICIAL Attention - (check al>propriats) No made to the fighting i� changes are w Q Leas than BOX of the fixtures ore new and irasta0ed tighting wattage is not being increased - CEILING LEGEND 0 C NTROLS MAXIMUM ALLOWED LIGHTING WATTAGE INTERIOR SYMBOL DESCRIPTION PTION Location (floor/room ) no. Occupancy Description po ry Pt Mowed Watts per s.F Area in S.F. Mowed X Area SECOND FLOOR B OFFICE 1.0 28,990 28,990 NEW SWITCH LOCATION EXISTING ( NOT SHOWN) « From Table 15-1 over - doasnent al exceptions taker from footnotes Tots Allowed watts 28,990 D _ NEW DIMMER SWITCH LOCATION PROPOSED LIGHTING WATTAGE INTERIOR (May not exceed told Mowed wolfs for Interior Location floor no.) ( /� ) Fixture Description Number of Fixtures watts fixture Watts Proposed 3 NEW -W C THREE AY SWITCH LOCATION COST OPTION SECOND FLOOR 2X4 FLUORESCENTi LIGHT FlXiURE 278 8 96 9 6 6 2 , 88 SECOND FLOOR RECESSED DOWNUGHT 60 26 1,560 • DESIGNATES SWITCHING CIRCUIT. . PROVIDE A COST - 1 OPTION FOR G TO BE T 5 BALLASTS THOUGHOUT UHT FIXTURES T E THE SPACE. SECOND FLOOR PENDANT FIXTURE 2 100 0 2 0 Total Proposed watts may not exceed Total Allowed watts for interior Total Proposed watts 28,448 I_• ®■t ■■imi•i1••mi ■ ■ ■■ ■•i i■■■■■■ ■= ■.i.•iU•i1 mum= ■■ u1■■1'1■®ul ■■ ■■ u ■ ®11■■■®■ ■■ ®1111 ■■■ ■■1111 iiiiii , iiiiininiiii i nililiirairiiiii . m\®■ u■ 1111■ 1121111111121111 112111111 1121111 ■11a■1i111:1■�i11 ■ii ■1111. ■411 ■ ®�f 11_ ■ ■11 ■ ■11 ■�I I _ _ �■■■ PA• ■■ ■0■ /!� 1111111111110111 I!1■ ■0111111 �' NI ■ ■ ® ■LA ■ ■ ■ ®C� ■ ■■ ■ ■ ■ ■�M■P �1 ■ ■i■■■i®� ■ ® ® ®® 1x11111111■ ■■ 11 ■ ■■ ■ ■ ■ ■ ■11�iiwaTAvn ®�i■I� ii■■ ■ ■ ■■iiiTAI ■ ■ ■I 111 11111111111111011111 11111111111M11111111111.11111111111 1111. , ��■■■■'■ 18 11a ®1■■■I_/.%a1111 ■ ■ ■!11 ■ ■®■■a■Cj ■a ■ ■ ■ ■ ■a ■L■■ ■ ■a ■ ■ ■ ■a ■ ■ ■ ■ ■a■ -•' ■Vo ii11iii ilEi :iii® "i ®liaiii®s®sii®i ® = - ■■ \ 11■ ■11 \ ■11■ 1 ■! ®=� ® ■ ■■ ■ ■ ■ ■■ ■■ ■1111■ ■ ■ ■ ■■ ■1111■ ■■ ® ® ®■ �■ ■1111■ i ®1111■ ■11■ ■ ■ ■ ■11■ ■ ■ ■■ ■ ■ ■ ■■ ® ■■ ' �. ■�■ ■ "`` 1 1■ \ i■ \ 1111 1111 11111 ■■ ® ■1111■ , ■�I■ii■ \ 1111■ \ ■■ ®11111■ 111111■ \ ■ ■11 \ 1111■ \ 1111■ \ 1111■ 1111■ \ 1111■ \ 1111■ 111111■ 1111■ \ 1111■ 1111■ \ 11■■ \ ■■■ \ ■■!!!�4smo . ui' It 1111■ f ■■ ■■®■■ ■ ■ ® ■ ■ ® ®■ I■■■ , 1111■ 1 ■■■ f l ■ ■® 1111■ 1111 ■■ 1111®® 1111■ 1111■ r :1 ■®■ , ■ ■■ 1 ■ ■■ Mill 11111■ ® ■■ ■X41 ■ ■■ 1111111 1111 ®■ f ■■ ■/� ®® ®®■- ■ ®11 ■ii 1iu 1111111111111111111111 ■ ■i ® ■! ®S 111 1 ® ® ®41 ® ■ ■ ® ® ■ ■i1� ■ ■■`21 ■ ■ ■ ®■ ■ ■ ® ■ ■■ 11! ■ ■ ■ ® ®11■! ® ■ ■ ■11■ ■ ® ®� ® ®1111■11■ ■ ■ ■® ■1121■ ■ ■21■■ ®■ ■1111■ ■ \ ONI IR ®id■■■ 111■■11 ® ■ ®Is■ii 11■ ■■ ■ ■1il ■ ■ ■■� ■�l ■ ■ ■ ■■11� ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■1l ■ ■ ■ ■■ ■1l11� ® ® ®11� ■ ■ ■ ■ ■ ■ ■■i1 1 ■11 ■■ ® ® ■11'■ ■ ■ ® ■11 ■■ ■ �1lo ■■\■ ■ ;TioIII ®11e i ■■ ■�11■a■■Ii■■ ■■ ®■■I ■ ■■ ■■■■■■■11 ■■ mmumummurim ■®i■■ ®■ ■11■■■■ ■ ■ ■■ ■11 onom ■■■!gismo ■■ ■■ ■■ ■ ■■ ■ ■■■ mum U. ® till! ■ ■I�1 1 ® ■■ imp IUIII■ \ ■ ■ ®\ mom= 1111 ■®■ ■e:1®® ® ®1l am ■ ■ ® ■■■ ■■■■ ■ ■■ ■ ■® ■11 ■■ ■ ®C 1 B ■■■■®■■■■■■■■■■■ 111151111711■ ■ ■111■ \ `1111 \ ■■ Mil ®■■■IIa ® ■a® r ■ICM r ■■ 1111\a ■■\ ■ ®a\ ■ ■■I 1111111111111111 1■au i iu\ 111■■\ ■■a \111111\1111■\■ ■a \ ■ ■■\ ®■\ ■■111 \1111 ■\a ■ ■ \■ o -•� . �1 ■1■©■ ®■ill! ®■i11 RINE ■111111■ f ■■■ ® ■mil 1 ■■ ■I 11 11i \ ■11■ \ �' f11■ ®uu f ■1111 , i11■ f 1111■■ 1111■■ ®11 ■■ ®�1 ■■ , ■■1v l 1111■ , �1 a f ■i fi ■ ■i■■ Ii10 ■i oiam■ii■ ■► 11 ■a ■ ■11 ■ ■ ■ ■ ® ■ ■i ® ® ®L!111■® ■ ®t5■ ■■ ■1111■ ®[�•C■ 1111■ fC1111 ■ ® ® ■ ® ■ ■■5I■ ■ ■ ® ■ ■■® ■ ■ ■ ©11 ■ ■ ® ■ ■ ■® 1111 ■ ® ■®� ■11 ■®■ ■ \ ■ ■ \■ I■ll\i iI ■ ■DO ■■ 1111111 ■®■11�11■®®■■I®o�: ■® 1111 ■ ■ ®■ ■■■ ■®111 ■1 ■® ®1111 ®11�.I1 ® ® ®11 ■■ 1111 ■ ■11 ■11 ■11 ■11111 ■1111 ® ■®■ ■■®■ ■® ■11. ■■ ■1111 ®■ ■! fCI ®■ -11111 fl!! ® ®® ■ 111111111111111111111111111111111, Ili 11 ■'G�11 ■ ■ ■ ■ ■ ■ ® ■■ ® ■11�®I� ® ®1 1-..1 ®11! 111111 1 111!■■ ®■1111■■■■1111■■■■i■■■■■ ■ ■ ■ ■■�11 1111111111111111111111111111111111111111111111111110111111 Ii ii T1' \■ ■III11\ ■Its ® \ ■I �' 11\ ■111 ■11■■ ■111 ■ ■ ■ ■ ■!1l ■Iii lm � i ■� if ■ ■ - ■■■ ■■■ 1l■■■■■ 1l ■ ® ® ■�■� ■ ■ ■ ■ ■■1 ■ ■ ■ ■11■� ■ ■ ■ ■ ■11 ■1 ' '® I■ENi!1 % ■ ■ ■■II iI ®a ■ ■II■ f®■® ® ■IC■ ® ■■■ \ ■ ■ ■ \ ■ ■ ■\ ■ ■■ 1 ►'` ■ ® ■f1■. ■111= 1■'® O\■■■\■■ i\® 11■\■® i\■■■\■■■\■ u ■ \ ■ ■ ■ \ ■11 ■ \ ■ ■I ® /, ■ 1C ■1!1 ■ ■ ®® 11115■Il1 ■ ■II■ ®■ ■ ® ® ■I ■ ■ ®■I ■■ ,11.11 1111 ■■ 1111■ ■1 [ ■■ \ ■r l■ \ C ■1� 1® f ®■ 1111 ■■ ®O ■■ 1111 ■■ 1111 ■■ 1111 ■■ ® ■ ■� ,1111■ 1111 ■■ 1111■■ ®1111■ \ ■11 \III ■S ■111 \ ■11 \ ■■ ®I■ B ; 1■ ■iii ■ ■i ®a■I ®Oi ®� ■ ■® ■ ■ ® ■ ■Ii® ■ ■ ■1 iii■ ® ■t 1■ r ■■ 1■ ■11�■® ■ini■■■■ ■11 ■ ■®■i 11■■® I+■■ © ■■ ■ ■ ■■�i11■�■■ 111 ®C■ ® 1111 \ill■ 11 f NI 11i■P 1!11111 ■ ■11 '■■.I=- I!■o ■ ■ ■Iil■ ■ ■■ ■111■'!■ ■■1® 1►i■ ® ■Ir ■EIIIMMl ■■ ® ®■ ■#1� ■!■ ■■. 1111■■ ■ ■ ■ ■11 ■ ■ ■■ 111® 1111 ■■I ® ®i!!■ ■ ■ ■ ■ ®■I ■■{'i■ ® ■ ®I.i ®IIIIII<Ii ■© ■■ 11111111111111111111111111111 ® OM REM ®■■■■■■■�1■ ■ ■ ■■ ■11,•1 ® ■ ■11® ■11.1!1 ® ■® 1111■� ■■ ■1111■ ■ ■ ■� ■ ®� a� ®® ■ ■ /■®®® ®■®®®1111 11 s■ ■iii I• 1111111111111111111111 rI \ ■■ iu \ ■■1111■■ I®■■ ® ■ ■ ■ ■ ■ ■■ 11N■®■®1Y ®gs®u iii ®®r l■ ■ ® ■ ® ® ■ ■ ■ ® ® ■ ® ® ■ ■ ■ ■ ■I� •e ■!.� E11 ■®1` 1 ■ ■ ■ ® ® ■11!ii/ ® ®11■ Rio ■ ■ ® ®i ®Ii ■■■�e■ iiii ® ■a f ■a•IN ■I ■►,ill \ ■11 ■ \ 1111®\ C ■ \ ®11111: ■ ■■1NII I ■■11 1 I■ \ 11N 1111■ \ ■11111■ \ NUN ■ ■ ■I ■■ 1111MI ■ \ 1 Il ■ ■ ■11111E 11■I I \ ■ �di1!1i ■ ®R ■■ . 1 ■■ _ � � . � _,, , � � , . - , � ®.1111■ , ■f111 inum1®■Iil f 1 1 \ '' I, ® f f f O f �� ■I■ 111 ■Iil �Il® 1111■ 1111■ 11111111 ■���.1�!1111 \�11 � ■ ® 1111■ ■■�■ ■11■ 111111►. \I�o \11� 1IC.o�11\ ®Ili \L...� \111 11 11.r \111 \ ® ■ ■ \ I1�\ �0 ■ \ .I.®®.e! ®� ® ®elos n onam momm ® ■■■ ® ■■■i c■ ® at like CAS 1■5� ®1111■ ■ ■®�I�■5■ ■�� ®O I■ ® ■U ®■ ■�■I II■s , ■■ ®4■ ■I I11■ f 11■ ®O T ' ® lU ®� Il ® ■ iii® ■s ni a ■iii■r® ®�_ iN IUI• ■ ■Us d� =i■I■ ■■ ■ :011111 ,.� 1■1 •. �2 8� 1115Li_.ISL ii�`�� lf5` 11�a11i�Or1a11■ ■ ®S ■ ■111►1'I� ►■�1111i1� ■ ®� ■11'l� ®11 ■III _1 ■11 ■1.1 ■i� 11111111■ ■ ■ ® ■i11CD■111111 ■111111: ,_� ■11�i €�� . 1 1�N! ■,I IUU�1 \ mime ■ ■ ■I ■111 \11■ ■U1�1 ■ ■ ■ ■■I ■ ■ ■ ■IiW® i s :® 1 ■ ■■■ ■ ■ ®�I■ 111■■■■:■■ ■ ■ ® ■■1®� ® ®�■i ■ ■ ■■11■IMIIIE7Il ■!0 !i11i� ■ ■ ■�1 ■■ 1 ■ ■�1 \UUI ■■ 1111■■■ ®O®® 1111■ ■I■■ ®V - ■i■UNIUU ■\UUUII 111 ■®Ut1■■ ■U11■\® ■ ■■\■ �am111■®■■ ' -•� ■■®®l1■■■1111WI ■■I<1�®l�■■ 111E ■EW1111■11®� 111111-��1p1■■■ 1111■■ ■■ ®®tIC ®11■® N ■■ ■I■■';I11 ®®■■ 1111■■ f■■ ■I 11111\ ■I111\111111■ 1 ®■ 1111■■ f■■■ fl!®M�! �,�o. ii■nstim ■i!g!u®®M®11■ ®�I®aINNEwam E 11211116 Ma'i1111 ®1111■I x! ® ■ ■ai ■ ■ ■® ■ ■IY CJ f all ■ 1 Cm 11m{'11 maim ■a■■■a .VIII /11■■ ■■VIII■ ■I C11 %, ■11 ■ ■ ■II ®� ■III ■ /� ■ ■ ■ ■ ®IIIUII _ -r-- _ .. _ . _ ,� � .. ,1111 ►■► C II Is ■u1 \ die l■ I ■l ®- pill ■ ®► ®I■R11 ■ ■ ■ ■I1 ■ ■ ■. I1 ■l . ■ ■ ®■!F 1 ®® ®�i�l'■ 1111 ■■1■ ■ ■ ■ ■ ■■! III{ / ■11 ■ ■ ■IiV/ ■ ■■ El ® ® _ r1■ \ ■■ \ ■ I■ ®■II�Ii1 ®\ ®\ ■111■ ■ 111111N11111111111§1.11111111111111101111111 ®■■■■■■■■■■ ■a ■ ®II ®�1U ® ■HIIINI !!Ii■■ ®®■■■■■■ii■ ■ ®1IIU 1111 \ ■II■ ■ \U® © I■a f®i ®■II®a`°ii■■ ®C■ ®■III® 111 ■■ ® ■■■■®■Ieh1 \11 tmel ®■■®®■■■■®■■ ■ ■■Ii i i:= ®i 1■■ ®U■ ■■■ ■ ® ■■ ■II■■ C�� 1 ■Ii■■ ,1111 - - - -- ® I■El IOF CE �' i11ii ■ri�l ■ ■� 11■1111MU 111211111111111111111111111 R� ®■■!■ \ ■ ® ■ \11■■ \ ®■!11 \11U 11111 ■UUI IU 1 UUI I■ \ ■ \ ■ ■i \ N ■O \ II■U ■■ MIll TO • � GE III ' ■MMO I■® Cii�■�II,..!•��� - °11 1 ®�■ I \■MINIP■i IMEMEN ■11 1U■U f■■■ f■■Il 1 ■■■ 1E1 \ ■1 : 1 ■ RU11■ INTO f■■I f■■■ liCamar iN ■ ®C�■ ■11 ®�■ r ■11 ■ ■ ■11■ - , I�■7 ■ ■ ■�I■■ ■Li® ■4. is ®■►111■■ f ■I�■ ��flP R ■ I■ ■ ■ © ■■1■ ■ ■ ■ ®� ■■1■ ■ ■ ■I ■111 ® ■1 1■ f ■111 TEN 111{11■ ■ ■111■ r ® ■■ Cad a � i 11 ■115�LI���illll ■11\11■ . .�\1111 \®1111 ®1a\ ■1111\ t■\■■ ■+ ra 1111111111■ 246,®Ii■■ ■ ■ ■ ■ ■ ■ ■ ■���■ ■1 ■AIIIII■I■C � 1 ■ ■ ® ■U ■ ■ ■ ■ ® ®U ■ODUCM ■■III■■ ■■ 111111111 l ■11 ®■11 ® ■II■ �l ■1l■ f1l ■■ 11UI ■®0■■■11� ® ■IUa \aUIUa_ ■■ ■■'11 ■■O■■11■ Miss® 1!11 ■ ®11mm11 ■Smini■■ ■es®�i1 rani \ ■ \■II■■ ® ■■ ® ■U U■ o I ■■ . '■ �I ■ ■11i1� •: 1�ii°i■ - __ -- . I■■C�r■ ■I ® ■■■Ci11C..i■■1111111C0110161111111111 ■ ® ■ ®� ®111 ■■J1111i1 ,#1�' ■■■ 11!!!11 1411 ® ■�11■X11 ■ ■11 ■11�h11i®g� wa ®®®®1111 ® ■Ih� ■ ■ ■ ®e ®11,111I1�■ 1111 ®■il�i ®■ • , 11.4•x® ■ o v © • J 1111' \�iO \'i ■ ■ \11■ ■®1111■ ■i■■ ®®i■■® ■■ mil ■■ i m■ ■■00■®■ ■®■ ®■■® ■®®■�■■■ ■® ■■ ■■■■■■■■■■ I■■■■ ■i.1■■■■■■ ■t■■■■■■■■■■ ■I■ ■a■ ■a■ ■■ \ ■®■■ \ ■■® glimul O FFICE ■ \ ■1 1N®■■■■■■■■■■■■■■■■ ■I■ \ Il'� •®\ 1111 ®a ■ ■.a ®■111 f ■■Il 238 11 11 11 ®111 ■ ■ \ ■1■■ ■ ■ ■ \ ■ ■ ® \ ■ ■ ■ ■I■ ® ®C� f■ 1111 ® ■ ■■`i 111111 ' ■ ■l ■"II II ®11111®■ f®®■ :111111111N1111111110.111111111111111111111111111111111111111 ■■■■®■■ ■®■1111 ■ ■I■■ ®■W ®I 11®■®®■■® ■ ■■ ®®■■®■®■ ■I■■■■■■■ 1111 1► sommou 111111101 Itammummo 11 !11®11 ® I ■® ®t�® 111311E 11E111111111111111 Lea ®III ■i ®111' �,'111111 t111 ■ ■ \® 11 OF FICE II ®■ � l�liii11l [�i ilifi11 ■ ■11 ■11't�►,tI.i 111 1111 2 6 II ■■ \ CJI Wall ■I 111/ 11 ■■ ®i�,g11'l�ll ®i ® ■1 1111\11'111 ®Il ®Il'll ®II ®Il ■1 �Il f ■Ill 1111 ® ■ ®II ® ® ■ 1■ \1111\■ 1111®® ®® ■■ ®■1 ■ ®11 ■. 1111■, , ■ 1111 \1111 ■ \® 111111 \1111® \111,1 ■11�1110�1■ 1111 11111!■ ®� f11 ■11 f11.�1■Il ■■1111® 11111111/11111111111111111111 ■■U■■■■C ■ im W!1!1■■■U■■ ■■ ®® ■® ® ■■■I__. ■ ®UI:lommel ■ ■a®® !!11+!;.117 ■ ® �� 1111 ■■11 ■11 ■� mumom ■i i a ■■ mos a■ ■■a!■ mum a■■Il ®�i� tl�■C�minu I ■ ■■ ■� ■ ■\ ®111111 \■, ■ \ ® ®'I11a11 ■ ®; '�■ ® ■11111 ®111® ® ■ ■� I ■ 111111 ■ ®EMIN I ■■ MINSIM ■:1111111 1111■ I- ■i a \ ■aI ■II ■VC��V ■■ Il 11.11 1■I�� f1111 1111■ ■ ®■ ■�UI ■m®■■a■■■ ■■UN®■ i■li■a ®■ 11®■■■■ - -- --- I■a ■■a■ IUII�a ■\ ■■ 111■ 1111 ■11 isa ■ ■a■■aiJal ■■a■ 1111 \ ■ TJ■ \ _ 1111®■ 1111■® f ■■ f 1111 � 119l1 � 1 � 9 � !! �i9�91�l191�! AGE • ■ lamilmin- moat m ■ ■ ■ ■ ■1 =1■ -ffm ii 1■■ ®111 1 1111 ®l � 1 ■■ ■ ® ®ei ■M■■ F�. 1I1 ■ \ ■I I . N NO iI ■■\■ L 1 m - ---.:I■ ® ■1 Ean ' IU 1111 1 illi iIa ■11■1.4� aOi■im ■s\2o7 gi 1■■ =�'1s ■ ■r -111■■■ It r ■ P111■ \ ■■11I11111a■ ®a■ ,) ® -- s�sss�s -rsr w _i h l .-zio r) ..1 t 7-411 ■iI �iiil ■ ® ■11�' 11111119 i■��I ■ ■fi`r<i■`III ■■■1ilio_ l,I I=:!®11■ iii, l■ \■Ilia ■■1'1 I■■a ■1E 1■ ®IIII■ ®■IIIWP' III ■r' i ®® ® ■I 1® ®■Ir IUNUII■■ ■11 ■■■11111111- i•■■i� 11 ■■� ■��1 II CEILING PLAN iI . ■L1■Il■ N ■■I■U■\■■■\■■■\■■■\®■ •=•� \■■■\ ■®■\■■■\ __■ \1111■\ ■NI fllill ■5•611111!1 liallI 1 ■®��co� .■o■m®ll®iilow '11.0 Ali ■11 1111■■ ®1111■ 1111■■ ®■ ■11 1111■■ ® ■e■ , 1111■ 1111■ 1111 ■■ 1 ■�� ®I i ■■L:11o1L' JI I �� 11 1111 ®111 ■■ 1 ■■ ®■ r®i11 ■NU P! 1111111■ \ \ ■■111 ■ 11811■■ �i ■ ■ ■11�■■ ■a11? ■ ■ ®�■i'® ■ ■ ■ ®11■■ ®® ■1121 ■ ■ ■� 11!11 ®® °'. \ ■11111 ®11 PHONE RM I ., �•, ■ ■115 ■11®5�■ ■■11111■ ® ■ ■ ■ ■ ■1 - ■11®II■ ©■ f ham■ ® ■ ■ ■ ■ ■■ ■1111■ ■ ■11 ■ ■ ■ ■■■ ■1111® ■Ill ■■ ■■ ■h■ ■■ ■ ■ ■ ■ ® ■®®1� ■1111■ ® ■11.1.1®■ �.> ® © I ■111111111111 ■ ■11 ■ ■ ■■ ®m® .....me muri- :■ ®_a®®m ®®®Im i ®®�®®sms� ®®��� ®- S®®- ®® ®® - ® e - ® ®® � -� ' 1111® ■5i■r 111 ■1111111111 - - - - -- 1■ : .. -.fir.: ` , x'11111 ■11 ®111111® ® ® ®� ■ ®i� ®III : �, mss- ; �: s a � I{i; r ® ® ® ® ®stro ■ ®111111 ■!111111 ■1111■■ I■■■ o .� -- § ■I00III ■I■I ■■ 1110111111111 _ i \ 111 ' ■ I ■1a l iI� \ ■■ !■ ■r■ T . ,r _ : , a� -� : ■ m11II ■I■1...: _. ■■ ■■ ■111■ ■I ■flll■ ■11111 l - ®� J � r ■ ■.1: x> ■111■ C� UIII ■ ■11 a 3 . � �x , :1 ■ ■ ®II■ ■'' :'!9■ ■\ ■Ili ■I 1111 \ ■ ®� ■__ - ' � � r> '� i �,'�� �. ''L^LL 1 1.: ��• � ice, •-• � ■ ®1111 ®11111►1 ® ■ ■ ®UIII■ \ 11 } x � !■ \ ■iI ■11 �I11 ■ r E I ®a1 .. �:. ::: 3a <x<aK.'or'e•:a t�. V.q :•k?a :raC S 'e��31 a■®I11 E L Yx s� nSa � Wi � r � ® .1 ■111117, ®11 ®iC� ®■;I Ii®■Ii 1111,,I ■1111®®■■ ■I '�® ■its � ��= • t � k xs .ti xr `�. '?'.'�c'yl:�w"�i t'a:Y � >!'^ •^x" `a^LY 2� J �� s v� <�. 1 111 ■11 111111 / Ili■® ��� r'2 .3....0 :o,- 'f'•':r. 1 `�, tcf^��.' •Y::L <.. l� �'l. ,_� \�_.11._,�. 1 ' ■�I .:1 1111 _ - -. -_- a ors u ...#` } � ' -^ ■�iiiiiiiiii.l� ®l��_ .� /1111®®® 1111® � 11■r m ■I :a \�i , � � ■.rJl O 11 11 '■� ■i■ �� IS■■_i■■■ omm- ■■ \ ■ ■� ■ ■ ■1111 ■�■i ® 111111111111111111111111111111111111 1111 ■ _ _ ■11 ■I REVIEWED FOR CODE COMPL APPROVED JUL 1 7 1009 City of Tukwila BUILDING DIVISION MEANS OF EGRESS ILLUMINATION IBC 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. IBC 1006.2 Illumination level. The means of egress illumination level shall not be less than 1 foot - candle at the walking level. IBC 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normal! .remises' electrical supply. be provided by the Y P Y P PP Y In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways.. 3. Exterior egress components... 4. Interior exit discharge elements. 5. Exterior landings...for exit discharge doorways... A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUiTE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 burgess design i interiors Q architecture 1326 Fifth Avenue Suite 506 . Sc file . WA 9A101 TEL: 206.587.7120 FAX:206. 587.7122 All reproduction Sc intellectual property rights reserved c 2009 Professional seal No. Issue Description REVIEW SET PERMIT SET 7196 REGISTERED ARCHITECT KIP G. t'teinal!EJS U STATE OF WAS HINGTON REFLECTED C CEILING IN G PLAN 6/22/09 6/25/09 24' b "al‘-- 11 1 Drown by: MK /TS Reviewed by: RECEIVED CITY F TUKWILA UKWI LA JUN ;2 9 2009 PERMIT RMIT CENTER AIR I KK Original drawing is 30" x .42 Scale entities accordingly if reduced W� L L MOUNTED DEVICES MISC. NOTATION KEYED SHEET NOTES EQUIPMENT LIST .. - VERIFY ALL REQUIREMENTS WITH TENANT SYMBOL DESCRIPTION GM DENOTES A GROUND FAULT INTERRUPT CIRCUIT SERVER ROOM:. 1 O COORDINATE POWER, COMMUNICATION, AND BTU OUTPUT WITH TENANT. 2 EXISTING ELECTRICAL IN THIS ROOM TO REMAIN. O 3 CONTRACTOR TO ALTER EXISTING ANGLE STOPS TO PROVIDE WATER LINES FOR REFRIGERATORS. , _ O4 WATER HOOK—UPS AND TIMERS FOR COFFEE MAKERS ARE TO BE NEW. CONTRACTOR TO VERIFY IF THERE ARE EXISTING HOOK —UPS PROVIDED. IF EXISTING, THEY MAY BE USED IF THEY ARE WITHIN 18' OF NEW LOCATION . 5 SEE RCP FOR ADDITIONAL REQUIREMENTS. VERIFY LOCATIONS WITH A/V VENDER. S AREA OF COAXIAL CABLE DISTRIBUTION. O 7 PROVIDE WATER LEAK SENSOR AT WET AREAS. 8 I TO EQUIPMENT UIPMENT IN LIEU OF PHONE BOARD EX STING RACK 0 REMAIN FOR VOICE Q 9 VERIFY MOUNTING LOCATIONS WITH TENANT'S A DRAWINGS. O N TENANT IS RESPONSIBLE TO MAINTAIN ALL LANDLORD SUPPLIED APPLIANCES. " N ( - s EXISTING TO REMAIN (VOICE /DATA OUTLETS NOT CONFIRMED FOR CAPACITY) T DENOTES TIMER E 1 REFRIGERATOR (BY TENANT, G.C. TO PROVIDE COPPER WATER LINE AND HOOK UP ICE MAKER AS REQ'D) 4 TOTAL 2 COFFEE MAKER (BY TENANT G.C. TO PROVIDE COPPER WATER LINE 2 TOTAL DUPLEX OUTLET ( MOUNTING ITf IN INCHES) (� ) C E \' R I V E 1 \ � L S 1 T S 1 E E � N O I E J DISHWASHER (BY G.C. — BUILDING STANDARD 4 —CYCLE RESIDENTIAL GRADE, VERIFY ADA COMPLIANCE, COLOR PER TENANT) 2 TOTAL �,e; QUADRAPLIXOUTLEf REFER TO PROJECT NOTES FOR CONSTRUCTION 1. REQUIREMENTS. Z. ELECTRICAL SUB — CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE WORKING CONDmON OF ALL EXISTING OUTLETS NOTED TO REMAIN. 3. ALL OUTLETS SHOWN ARE APPROXIMATE. DUE TO HIDDEN CONDITIONS ADDMONAL P /P /D MAY EXIST BUT NOT BE REFLECTED ON THE PLANS. 4. FURNITURE SHOWN FOR INTENT ONLY, FINAL LOCATION OF FURNITURE AND OUTLETS TO BE COORDINATED WITH TENANTS FURNITURE VENDOR. VERIFY ELECTRICAL AND VOICE /DATA REQUIREMENTS WITH TENANT. 5. ALL DAT A, TELEPHONE, WIRING AND SECURITY BY TENANT: 6. ALL CONFERENCE ROOM MEDIA EQUIPMENT FURNISHED AND INSTALLED BY TENANT, INCLUDING ALL POWER, DATA AND. VIDEO. _ 7. MODIFY CEILING ELECTRICAL J—BOXES FOR NEW POWER POLES. w 8. SCHEMATIC ELECTRICAL AND .VOICE DATA DESIGN EXISTING IF SHOWN WITHIN 18 OF EXISTING / N CAN REUSE EX Sll TI LOCATION. ' 9. TENANT'S FURNITURE CONNECTED BY TENANT'S ELECTRICIAN. 10. DESIGN BUILD ELECTRICIAN SHALL VERIFY EMERGENCY PATHWAY WITH FINAL FURNITURE LAYOUT. ALL FURNITURE AND WIRING TO SYSTEMS FURNITURE SUPPLIED BY TENANT. 11. P 12. ALL AV EQUIPMENT AND WIRING SUPPLIED BY TENANT. 4 UNDER COUNTER REFRIGERATOR BY TENANT) 1 TOTAL ( ) I� DEDICATED DUPLEX OUTLET 5 HOT WATER HEATER (BY G.C. — COORDINATE LOCATION WITH BUILDING MANAGEMENT AND CODE COMPLIANCE) 6 NEW GARBAGE DISPOSAL ) ( BY G.C. 1 TOTAL J I-O JUNCTION BOX _ CAT6 2 X AT DATA WITH RJ45. CONN ECTIONS GENERAL c T \' S J E I I V O T E J HE � 1 X CAT6 DATA WITH RJ45 CONNECTIONS 10 A REQUIREMENTS AT SYSTEMS FURNITURE. TENANT PREFER OUTLETS GO TO O DRAWINGS SHOW /V Q EFER TH IS O GENERAL CONTRACTOR WILL VERIFY POWER REQUIREMENTS AND OUTLET LOCATIONS WITH LOCATION. G Q TENANT... 11 VERIFY LOCATION WITH TENANT'S FURNITURE. Q 1 OUTLETS FOR SECURITY PANELS.' VERIFY LOCATION WITH TENANT VENDOR. DEDICATED • O 13 � � A PROJECTOR DEVICE IN CEILING. VERIFY REQUIREMENTS AND LOCATION WITH FINAL A DRAWINGS. O. A SCREEN POWER. O /V CONTRACTOR SHALL PROVIDE (2) ' ( ) COAXIAL CABLES FROM ROOF TOP DISH TO LOCATION IN SERVER ROOM. DISH INSTALLATION IS NON— PENETRATING. b 1 X CAT6 VOICE WITH RJ11 CONNECTIONS ® — VOICE/ DATA POWER POLE VERIFY SYSTEMS FURNITURE REQUIREMENTS FOR POWER AND VOICE DATA W/ TENANT. — POWER WHIP VERIFY SYSTEMS FURNITURE REQUIREMENTS FOR POWER AND VOICE DATA W/ TENANT. I 1 PW NEW CARD READER (G.C. TO PROVIDE REQUIRED POWER) CR COAX CABLE TV OUTLET NEW CONFERENCE J ry /`` VIEWED FOR BODE COMPLIANCE APPROVED JUL 17 2009 RM. ® Qi, O N C N C N I N C N I N C N I N C N I N N N MN MNMNMNMN r M ti) NMc*/ J J J J J J J J J J J J :1A3 % //�� � %! r jr �% %.�i SA %G%i' %G�i. L %.'. %i %'' % /. %n / /7.G� %4%' %#/ A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB . RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 burgess design I interiors ® architecture 1326 Fifth Avenue Suite 500 . Se tt1C . WA 96101 TEL: 206.5117.7120 FAX:206. 587.7122 All reproduction & intellectual property rights Issue Description KIP G. I(OLCDZIEJS:C STATE OF WASHINGTON 9- I11 Drawn by: MK /TS Project No: 09- SB04 - Reviewed by: KK POWER AND DATA PLAN RECEIVED CITY OF TUKWILA JUN 2 9 2009 PERMIT CENTER Original drawing is 30" x 42". Scale entities accordingly if reduced , NEW CONFERENCE AV NEW OPEN OFFICE FIELD CARPET COLOR: TBD INSTALLED: DIRECT GLUE EXECUTIVE AREA CARPET COLOR: TBD INSTALLED: OVER PAD PLASTIC LAMINATE HORIZONTAL SURFACES /BACKSPASH. LAMINATE COLOR: INTERIOR MELAMINE COLOR 4'h COVED RUBBER BASE. COLOR: TBD PLASTIC LAMINATE VERTICAL SURFACES LAMINATE COLOR: - INTERIOR MELAMINE COLOR MATCH DESIGNERS SAMPLE GWB EGGSHELL FINISH COLOR: - GWB EGGSHELL FINISH COLOR: — WOOD DOOR /FRAME SATIN LATEX FINISH COLOR: — ELECTROSTATIC PAINT COLOR: GENERAL FINISH NOTES 1. PROVIDE 8 -1 THROUGHOUT, UON. 2. PROVIDE P -1 THROUGHOUT, UON. 3. PROVIDE CPT -1 THROUGHOUT, UON. 5. CENTER TRANSITION BEIWEEN MATERIALS UNDER DOOR PER DETAILS. 6. ALL EXISTING DOORS TO BE PAINTED TO MATCH NEW DOORS. 7. FOR BUILDING PURPOSES. USE 30oz CARPET. 8. CLEAN ALL WINDOW BLINDS ON JOB SITE 9. ALL NEW CASEWORK ID FOUND ON A.2A.1. REFINISHED CASEWORK IS FOUND ON A.2D.1. KEYED SHEET NOTES FLOORING IN THIS ROOM IS EXISTING TO REMAIN. REFINISH EXISTING WOOD RECEPTION DESK TO WD -1 FINISH. PROVIDE NEW WD -1 TOPS ON EXISTING CASEWORK. PROVIDE A COST OPTION TO REPLACE CASEWORK WITH NEW WD -1 EXTERIORS AND GREY PLASTIC, LAMINATE INTERIORS. ELECTROSTATICALLY PAINT WOMEN'S RESTROOM PARTII1ONS WITH P-X. PROVIDE NEW WALL PANELS TO MATCH EXISTING AND DEMO'D WALL PANELS. PANELS FINISHED IN WD -1. A Tenant Improvement for: SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE, WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 burgess design J interiors architecture 1326 Fifth Avenue Suite 500. Se the . WA 98101 TEL: 206.507.7120 FAX :206. 587.7122 M reproduction & intellectual property rights reserved c 2009 REVIEW SET PERMIT SET Drawn by MK /TS Reviewed by: Project No: 09- SBO4 -00 FINISH FLOOR PLAN RECEIVED CITY OF TUKWILA JUN 292009 PERMIT CENTER Original drawing is 30" x 42 ". Scale entities accordingly if reduced a DEVICES SHOWN STACKED IN PLAN ARE TO ALIGN VERT. PS SHOWN BELOW a a CARD READER WHERE OCCURS I61 a AT LOCATION AS DIMENSIONED ON PLAN;. OR NEXT TO DOOR / OPENING AS DIMENSIONED BELOW FIRE ALARM STROBE FRAME WHERE OCCURS ROOM SIGNAGE, ETC. THERMOSTAT LIGHT & PROJECTION SCREEN SWITCHES, WALL MOUNTED OCCUPANCY SENSOR HARDWARE LATCH FINISHED FLOOR TELEPHONE OUTLET ELECTRICAL OUTLET 1. LOCATED SWITCHPLATES, ELECTRICAL AND TELEPHONE WALL OUTLETS AT NEAREST STUD FROM SCALED LOCATION ON PLAN, UNLESS SPECIFICALLY DIMENSIONED ON PLAN, ELEVATION, OR LOCATION AS PER DIAGRAM ABOVE. 2. CENTER FIRE ALARM STROBES DIRECTLY ABOVE FIRE EXTINGUISHER CABINETS WHERE BOTH OCCUR. GENERAL DEVICE ALIGNMENT BACKSPLASH (WHERE OCCURS) SCRIBE TO WALL COUNTER TOP FOR FINISHES SEE A.2A.1- AND A.2D.1. 3 STUDS MIN. NOTE: COORDINATE ANCHOR BRACKET LOCATIONS W CASEWORK & EQUIPM WHERE SCHEDULED, AND MANUF. MOUNTING INSTRUCTIONS BOTTOM OF FINISHED CEILING ANCHOR BRACKET: 6"X16ga UNPUNCHED STUD TRACK, ATTACH TO 3 STUDS MIN FINISHED FLOOR TYPICAL ANCHOR BRACKET FRAMING 1008.1.3.4 ACCESS – CONTROLLED EGRESS DOORS. THE ENTRANCE DOORS IN A MEANS OF EGRESS IN BUILDINGS WITH AN OCCUPANCY IN GROUP A, B, E, M, R -1 OR R -2 AND ENTRANCE DOORS TO TENANT SPACE IN OCCUPANCIES IN GROUPS A, 8, E, M, R -1 AND R-2 ARE PERMIT Itll TO BE EQUIPPED WITH AN APPROVED ENTRANCE AND EGRESS ACCESS CONTROL SYSTEM WHICH SHALL BE INSTALLED IN ACCORDANCE WITH ALL OF THE FOLLOWING CRITERIA: A SENSOR SHALL BE PROVIDED ON THE EGRESS SIDE ARRANGED TO DETECT AN OCCUPANT APPROACHING THE DOORS. THE DOORS SHALL BE ARRANGED TO UNLOCK BY A SIGNAL FROM OR LOSS OF POWER TO THE SENSOR. LOSS OF POWER TO THAT PART OF THE ACCESS CONTROL SYSTEM WHICH LOCKS THE DOORS SHALL AUTOMATICALLY UNLOCK THE DOORS. THE DOORS SHALL BE ARRANGED TO UNLOCK FROM A MANUAL UNLOCKING DEVICE LOCATED 40 INCHES TO 48 INCHES (1016mm TO 1219mm) VERTICALLY ABOVE THE FLOOR WITHIN 5 FEET (1524mm) OF THE SECURED DOORS. READY ACCESS SHALL BE PROVIDED TO THE MANUAL UNLOCKING DEVICE AND THE DEVICE SHALL BE CLEARLY IDENTIFIED BY A SIGN THAT READS "PUSH TO EXIT.' WHEN OPERATED, THE MANUAL UNLOCKING DEVICE SHALL RESULT IN DIRECT INTERRUPTION OF POWER TO THE LOCK – INDEPENDENT OF THE ACCESS CONTROL SYSTEM ELECTRONICS -AND THE DOORS SHALL REMAIN UNLOCKED FOR A MINIMUM OF 30 SECOND. 4. ACTIVATION OF THE BUILDINGS FIRE ALARM SYSTEM, IF PROVIDED, SHALL AUTOMATICALLY UNLOCK THE DOORS, AND THE DOORS SHALL REMAIN UNLOCKED UNTIL THE FIRE ALARM SYSTEM HAS BEEN RESET. . ACTIVATION OF THE BUILDINGS AUTOMATIC SPRINKLER OR FIRE DETECTION SYSTEM, IF PROVIDED, SHALL AUTOMATICALLY UNLOCK THE DOORS. THE DOORS SHALL REMAIN UNLOCKED UNTIL THE FIRE ALARM SYSTEM HAS_ BEEN RESET. ENTRANCE DOORS IN THE BUILDINGS WITH AN OCCUPANCY IN GROUP A, B, E AND M SHALL NOT BE SECURED FROM THE EGRESS SIDE DURING PERIODS THAT THE BUILDING IS OPEN TO THE GENERAL PUBLIC. NOTES: TYPICAL ANCHOR BRACKET ASSEMBLY FOR HANDRAILS, GRAB BARS & TOILET ACCESSORY ANCHORAGES. COORDINATE ANCHOR BRACKET LOCATION WITH ACCESSORY MANUFACURER MOUNTING INSTRUCTIONS. PROVIDE MIN 25 GA STUDS & ANCHOR BRACKET ANCHORAGES. DOUBLE STUDS END OF MUTTONS. 3-118 PAN HEAD SHT. SCREWS 6 x16 GA UNPUNCHED STUD TRACK WITH FLANGES COPED AT VERTICAL STUDS. ATTACH TO TWO STUDS MIN. & EXTEND 6'MIN BEYOND MOUNTING POINT EACH DIRECTION. SUPPORT BRACKET © 24" O.C. MAX.: = 1' —o" HARDWARE GROUP HARDWARE GROUP GROUP 1 EXISTING HARDWARE GROUP 2 PAIRED, GLASS DOOR HARDWARE NON– RATED GROUP 3 SINGLE, ENTRY LOCKSET NON –RATED GROUP 4 SINGLE, PASSAGE LATCHSEF NON -RATED GROUP 5 SINGLE, OFFICE LOCKSET NON –RATED GROUP 6 SINGLE, STOREROOM LOCKSET NON –RATED GROUP 7 PAIRED, PASSAGE LATCHSET NON –RATED GROUP 8 SINGLE, PRIVACY LOCKSET NON –RATED GROUP 9 SINGLE, PUSH -PULL NON –RATED SIDELIGHT /GLAZING SCHEDULE SIDELIGHT 7 -4' 7 -4' 7, -4' 7 -4" 0" 7 -0s FULL HT FULL HT FULL HT FULL HT FULL HT 2' -0" 7' -6" 3' -6" 4' -6' 6' -2" VARIES C HARDWARE 2 DEAD BOLT LOCKSEF AT BOTTOM RAIL 2 PAIR PIVOT HINGES 2 B/S 'D' PULLS EACH SIDE 2 AUTOMATIC FLUSH BOLT 2 DUST PROOF STRIKE 2 DOOR CLOSERS – INTEGRATE INTO HINGES 2 WALL– MOUNTED DOOR STOPS 1 CARD READER 1 MAG LOCK, MUST COMPLY W/ IBC 1008.1.3.4 1 ENTRY FUNCTION LOCKSEF 1.5 PAIR HINGES 1 DOOR CLOSER 1 FLOOR - MOUNTED DOOR STOPS 1 ELECTRIC STRIKE, MUST COMPLY W/ IBC 1008.1.3.4 1 PASSAGE LATCHSEr 1.5 PAIR HINGES 1 WALL- MOUNTED DOOR STOP 1 OFFICE FUNCTION LOCKSET 1.5 PAIR HINGES 1 WALL– MOUNTED DOOR STOP 1 STOREROOM FUNCTION LOCKSET 1.5 PAIR HINGES 1 WALL – MOUNTED DOOR STOP 1 DUMMY PASSAGE LATCHSETS W/ ROLLER CATCHES 3 PAIR HINGES 2 OVERHEAD DOOR STOP 1 DOUBLE DOOR SEAL 1 THRESHOLD 1 DOOR BOTTOM 1 ASTRAGAL 1 PRIVACY LOCKSET W/ OCCUPANCY SENSOR 1.5 PAIR HINGES 1 WALL - MOUNTED DOOR STOP 1 PUSH –PULL 1.5 PAIR HINGES 1 WALL – MOUNTED DOOR STOP 2 KICK PLATES EACH SIDE 1/4" TEMPERED 1/4" TEMPERED 1/4" TEMPERED 1/4" TEMPERED 1/4" TEMPERED 1/2" TEMPERED CD z WD WD WD WD WD ALUM REMARKS CONNECTED TO TENANTS CARD READER SYSTEM CONNECTED TO TENANTS CARD READER SYSTEM VERIFY USE OF ROLLER CATCH WITH ACOUSTICAL SEAL CLEAR STORY ABOVE DOOR TO BE FULL HT. VERIFY SILL HEGHT VERIFY SILL HEGHT VERIFY SILL HEGHT VERIFY SILL HEGHT MATCH EXISTING CONDmONS SIDELIGHT ' GLAZING TYPES CD LU N GLAZING AS SCHEDULED PAINT GRADE WOOD FRAME GLAZING AS SCHEDULED = EXISTING, MATCH AIL EXISTING CONDITIONS WIDTH GLAZING AS SCHEDULED PAINT GRADE WOOD FRAME FRAMELESS GLASS SUPPORT 1/2" TEMPERED GLASS SEE OTHER EXAMPLES IN LOBBY DOOR TYPES CD W )E0, 2' -O CD w WIDTH WIDTH PAINT GRADE WOOD FRAME 1/4" TEMPERED GLASS FLUSH S.C. PAINT GRADE WOOD DOOR PAINT GRADE WOOD FRAME FLUSH S.C. PAINT GRADE WOOD DOOR 2 = EXISTING, MATCH ALL EXISTING COND[ONS WIDTH FLUSH S.C. PAINT GRADE WOOD DOOR WIDTH D PAINT GRADE WOOD FRAME B/S FINISH NEW HERCUUTE TEMPERED GLASS DOORS. B/S FINISH SEE OTHER EXAMPLES IN BUILDING 3 –O" E E 6' -0' 3 -0" 3' -0" 3' -0' E 7' -0" A E E 7'-0" 7' -0 7' -0" 7' -0" E E E C B A A E City of DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME 0 HEAD. REFER TO SPECIFICATIONS FOR CLEARANCES. DOUBLE DOOR NOMINAL WIDTH INDICATES 2 DOOR LEAVES OF EQUAL WIDTH, U.O.N. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH – BOLTS. 5. DOOR / HARDWARE SHALL COMPLY 6. ALL EXISTING "A' TYPE DOORS TO 7. SPECIFICATIONS FOR ACOUSTIC HARDWARE: • PEMKO S88 DOUBLE DOOR SEAL • PEMKO 2001 THRESHOLD • PEMKO 430 AUTOMATIC DOOR BOTTOM • PEMKO 355S ASTRAGAL D 0� PROVIDE NEW CARD READER VERIFY OR PROVIDE VERIFY OR PROVIDE VERIFY OR PROVIDE VERIFY OR PROVIDE VERIFY OR PROVIDE 11 1 CODE C APPR PROVIDE SOUND INSULATED DOOR, ACOUSTICAL SEAL AND SHOES. PROVIDE FILM ON GLASS PANEL PROVIDE FILM ON GLASS PANEL kwi1a BUILDING DIVISION VERIFY OR PROVIDE VERIFY OR PROVIDE VERIFY OR PROVIDE VERIFY OR PROVIDE MODIFY FOR CARD READER ACCESS ASSEMBLY MODIFY FOR CARD READER ACCESS ASSEMBLY MODIFY FOR CARD READER ACCESS ASSEMBLY D CE 9 VERIFY OR PROVIDE VERIFY OR PROVIDE VERIFY LOCK, PROVIDE ACOUSTICAL SEAL, SHOES AND THRESHOLD. PROVIDE NEW CARD READER ACCESS ASSEMBLY DOOR & HARDWARE GENERAL NOTES . PROVIDE YALE HARDWARE WITH LEVER TO MATCH EXISTING, US 626 BRUSHED CHROME FINISH. SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION. DOOR SCHEDULE 200A 6' -0' FULL HT 200B 202 E 203 3' -0" 7' -0" 204 3' -0" 7-0" 205 3' -0" 7' -0' 206 3' -0" 7' -0' 207 208 209 210 211 212 213 214 215A 216 3' -0" 7' -0' 217 218 3' -0" 7' -0" 219 3' -0" 7' -0' 220 3' -0" T -0" 221 3' -0" 7' -0" 223 3' -0" 7 -0" 226 3' -0" 7' -0" 227 3' -0" 7' -0" 228 3' -0' 7' -0" 229 3' -0' 7-0' 230 3' -0" 7' -0" 232 3' -0' 7' -0" 233 3' -0" 7' -0' 234 ` 3' -0' 7' -O' 235 3' -O' 7'. -0' 236 238 3' -0" 7' -0' 239A 239B 241 3' -0" 7' -0" 242 243 3' -0" 7' -0" 244 245 246 E 247 248 E 249A E 249B 250A E 250B 251 3' -0" 7' -0" 252 3' -0" 7-0' 253 254 3' -0" 7' -0" 255 256 258A 3' -0" 7' -0' 258B E 259 3' -0" 7' -0" 260 3'4" 7' –O' 261 3' -O" 262 3' -0" 7' -0" 263 3' -0" 7' -0" 264 3' -0" 7-0" 266 267 268 3' -0' 7' -0' 269 3' -0" 7' -0' 270 3' -0" 7' -0' 271 3' -0" 7–O' 272 3' -0' 7' -0" 273 3' -0" 7' -0' 274 3' -0" 7' -0" 275 3' -0' 7-0" 276 3' -0" 7' -0" 277 3' -0" 7' -0" D WD WD WD A WD WD WD WD WD WD 5 WD WD WD WD 5 WD B WD A WD WD WD WD WD WD WD WD WD WD. WD WD WD WD A WD 4 WD WD A E WD E WD WD 3 WD WD E WD WD 6 WD WD WD WD WD WD WD WD WD A WD 5 WD WD WD WD WD WD WD WD. WD WD WD WD WD WD WD WD WITH ALL APPLICABLE IBC & ACCESSIBIUTY REQUIREMENTS. HAVE CUT OUT IN EXISTING DOOR FOR NEW VISION PANEL CD z w /O 111111111111111111M1111 1 1 111111111111111111111 41 ,PIP4o141, jl '♦ El j�1,1 los ow l 4 ti,424, 1/4' 4 80TTOM OF STRUCTURE WHERE PART. TYPE IS INSULATED PROVIDE ENCAPSULATED ACOUSTICAL BAIT EXTENDING 24' EACH SIDE OF PARTITION. NON -RATED FLOOR TO 12" — 2"X2'X12' MIN. LEG AT STRUCTURE – ATTACH W/2 POWDER DRNEN FASTENERS PER BRACE OR OTHER APPROVED METHOD PLENUM HEIGHT OF 5' –O' OR LESS 2 1/2'x25 GA METAL STUD BRACING 0 8' - 0' OC TO STRUCTURE DIRECTION ALTERNATE. PARTITIONS PERPENDICULAR TO PARTITION ACT AS BRACE PLENUM OF 5' -0' TO 1O' -0' SHALL USE NESTED OR BACK TO BACK 3 -1/2' 25 GA. STEEL STUDS. ABOVE 10' –O' OR PLENUM. CONTACT ARCHITECT FOR ADDITIONAL INFORMATION. MAX PARTITION WEIGHT 15Ibs. /P.S.F. SUSPENDED CEILING AS SCHEDULED 3/8' CONT. FOAM SOUND ISOLATION TAPE TAPEABLE MET. TOP TRACK ATTACHED TO BRACING W/2 SELF – TAPPING SM. SCREWS 0 48 oc, AND 3/4° PIPE SLEEVES INSULATION UON ON PLANS 3 1/2' X 25 GA METAL STUDSO24'OC,TO 10' -9' MAX. HEIGHT. 1 LAYER 5/8' TYPE 'X' GYP. BD. EA. SIDE OF METAL STUDS POWDER DRIVEN FASTENER 0 24' OC MET: RUNNER TRACK SEALANT CONCRETE SLAB CEILING PARTITION A Tenant Improvement for. SABEY 12201 TUKWILA INTERNATIONAL BLVD. SUITE 400 SEATTLE,: WA 98168 Tenant: APB RIVERFRONT TECHNICAL PARK 2811 SOUTH 102ND STREET TUKWILLA, WA 98168 burgess design J interiors 4) architecture 1326 Fifth Avcnue Suite 500 _ Seattle . WA 98101 TEL: 206.587.7120 FAX:206. 587.7122 M reproduction & intellectual property- rights reserved c 2009 Professional seal 7196 REGISTERED ARCHITECT KIP t=. KOLWDZIEJSKI STATE t3FW S1GT J No Issue Description Date REVIEW SET PERMIT SET by: /T Re wed by: Pro ect No: MK 09— SBO4 -00 S evi ` 6/22/09 6/25/09 DOOR SCHEDULE/ SIDELITE SCHEDULE / DETAILS RECEIVED CITY OF TUKWILA JUN 2 9 2009 PERMIT CENTER KK Original drawing is 30" x 42 ". Scale entities accordingly if reduced A.9.1