Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D09-122 - WESTFIELD SOUTHCENTER MALL - PREMIER SKIN CARE - KIOSK
PREMIER SKIN CARE 2800 SOUTHCENTER MALL K -9010 D09 -122 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Section 110.2 of the 2006 edition of the International Building Code. At the time of issuance, this structure or portion thereof has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. Building Permit No.: D09 -122 Occupant /Tenant: PREMIER SKIN CARE Building Address: 2800 SOUTHCENTER MALL, K -0242, SUITE NO. Parcel No.: 6364200010 Property Owner: WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA 90025 Use: RETAIL SALES Occupancy Group /Division: B Type of Construction: VB Automatic Sprinkler System: Provided: Y Required: Y Design Occupant Load: N/A BUILDING 0 FICIAL 4 5/, 297 T E THIS CERTIFICATE TO BE CONSPICUOUSLY POSTED ON THE PREMISES Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Phone: Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 Cityf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 6364200010 2800 SOUTHCENTER MALL TUKW PREMIER SKIN CARE 2800 SOUTHCENTER MALL, K - 0242 , TUKWILA WA Contact Person: Name: DAVE NELSON Address: 19419 SE 240 ST , COVINGTON WA 98042 Phone: 206 713 -1507 Contractor: Name: PREMIER RENOVATIONS Address: 19419 SE 240 ST , COVINGTON WA 98042 Phone: 425 413 -9195 Contractor License No: PREMIR *963JH $1,520.00 SPRINKLERS DEVELOPMENT PERMIT WEA SOUTHCENTER LLC BSIP TOTAL 13 PARCEL NUMBERS , 2010 NEW PLAT MAJOR 920247 00000 * *continued on next page ** D09 -122 Permit Number: Issue Date: Permit Expires On: Expiration Date: 04/08/2010 D09 -122 07/23/2009 01/19/2010 DESCRIPTION OF WORK: INSTALL A 150 SF PRE - FINISHED STICK DOWN HARDWOOD FLOORING. INSTALL PRE - BUILT /ASSEMBLED FURNATURE (KIOSK) Fees Collected: International Building Code Edition: Occupancy per IBC: $176.10 2006 0019 Printed: 07 -23 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Water Main Extension: Water Meter: N Permit Center Authorized Signature: The granting of this construction or th doc: IBC -10/06 City dtTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non- Profit: N Private: Public: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will , e complied with, whether specified herein or not. t does orm- . Permit Number: D09 -122 Issue Date: 07/23/2009 Permit Expires On: 01/19/2010 Date: ` V resume to give authority to violate or cancel the provisions of any other state or local laws regulating rk. I a . . - rized to sign and obtain this development permit. Signature: Print Name: / Alv'4 /7. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -122 Printed: 07 -23 -2009 Parcel No.: 6364200010 Address: Suite No: Tenant: PREMIER SKIN CARE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 11: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2800 SOUTHCENTER MALL TUKW 13: Post address on kiosk per approved Westfield standards. PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D09 -122 ISSUED 07/06/2009 07/23/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 15: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at D09 -122 Printed: 07 -23 -2009 (206)575 -4407. doc: Cond -10/06 0 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** D09 -122 Printed: 07 -23 -2009 • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the perf. , ance of work. Signature: Print Name: doc: Cond -10/06 1/1/e/ / /fey i) X 4/0 0-k/ D09 -122 Date: 7 -05-05 ordinances governing or local laws regulating Printed: 07 -23 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup://www.ci.tukwila.wa.us SITE LOCATION Tenant Name: King Co Assessor's Tax No.: CJ ` / v Site Address: (7) jl ti/?7`/ -e TL Suite Number: O /D Floor: ?AE/vl /GQ SLin/ New Tenant: ❑ Yes Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** .. No Property Owners Name: lif / /cj ,G� FLZ /Nia (54/77/Chl./700 Mailing Address: 66-6 City CONTACT PERSON - who do we contact when your permit is ready to be issued Name: t /17�Ls'D. Mailing Address: / \\ 9 ¥/ 9' s Z¢D � S/ ("an/t��r E -Mail Address: I , , Pi,-6 fi.4 t Ftt- nnc'' T /✓S- r Company Name: f V Mailing Address: /Q , f/9 4G- Z-4 ' Sr. (jj/rj6 /U'J H\Applications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1 -2009 bh City Contact Person: ))A-tlb Af& - O,V/ Day Telephone: E -Mail Address: . / 9 w E -? /LEwr 1 f✓ i'l-) CO3 r4/i — Fax Number: Contractor Registration Number: ?/ /L 94 v/ I Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Building Permit No. Mechanical Permit No. Permit No, Public Works Permit No, Project No. (Fo'r'office use only) State Day Telephone: 7.)b -7 /3 — /SP 7 98/ �x Zip State Zip Fax Number: .1Z5 ¢/ / 79 7 C ity GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) f.r '1 State Zip Zo 6 - 7' ' 15"07 797 Expiration Date: O ¢ a g - c 2 ARCHITECT OF RECORD -All plans must be wet stamped by Archit y et of Record Company Name: , AtiwCL Mailing Address: b ' 5 5ctil'ervij _ 7 UFO) �tf,¢GC) ,C7 �i't- 98/'75 Contact Person: M/yvC (3g/g/6 Day Telephone: Cam — '07 — (0O 7p E -Mail Address: 4d/f/ rev s '7" / e5,9, Of Fax City State Zip ENGINEER OF , RECORD - All plaii;'mustbe wet stamped by Engineer n ecor State Zip Page 1 of 6 Will there be new rack storage? ❑ Yes BUILDING PERMIT INFORM.A,TION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ /5o, 3 Existing Building Valuation: $ Scope of Work (please provide detailed information): �1V ow /50 5 . r, 4F / 6 i�S /�,0 5 f JWQOD /N P?X/ , Bvr -r `fi-s'.SE -n 4%19) No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 1 Floor rd Floor 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Interior Remodel Addition to Existing Structure Type of Construction per 113, C Type of Occupancy per IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm [one ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H.\Applications\Forms- Applications On Line \2009 Applications \I -2009 - Permit Application.doc Revised: 1.2009 bh Page 2 of 6 PERMIT APPLICATION NOTES Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature: O� E R AUT ��D,AG Print Name: v Affrr 4 4 • /"EL -SoA Mailing Address: /g '/ 9 S� Z¢0 �T �QuitiG Date Application Accepted: VA H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh City Date: 7 -" `"O7 Day Telephone: 246_ 7/5 /tD7 State Staff Initials: .6?o¢Z Zip Date Application Expires: OE 10(1110 Page 6 of 6 Fixture Type: Qty Fixture Type: Qty Fixtur ype: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes w. ser, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fount. or water cooler -r head) Food -waste grl''iyer, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Wat heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 allon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) ' epair or alteration of water piping and /or water treatment equipment Repair or alteration of drainage or vent piping dical gas piping sys "` -,± serving 1 -5 inlets'':, tlets for a specific Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn `i, inkier system on any'''ne meter including backfl. protection devices Atmospheric -type va m breakers not includ- in lawn sprinkler ba• ' ow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets PLUMBING AND GAS PIPING PERMIT INFORMATION - 206- 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration mber: Expiration Date: Valuation of Project (contractor's . 'd price): $ Scope of Work (please provide detail- information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and /or gas piping out s being inst ed and the quantity below: H:\ApplicationsWorms- Applications On- Line\2009 Applications \1 -2009 Permit Application.doc Revised'. 1 -2009 bh s at Zip Page 5 of 6 Receipt No.: R09 -01026 Initials: User ID: Payee: JEM 1165 ACCOUNT ITEM LIST: Description DAVID A NELSON Payment Credit Crd VISA - Authorization No. 04521D BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount RECEIPT 176.10 Account Code Current Pmts 000/322.100 000/345.830 640.237.114 104.00 67.60 4.50 Total: $176.10 • Parcel No.: 6364200010 Permit Number: D09 -122 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/06/2009 Applicant: PREMIER SKIN CARE Issue Date: Payment Amount: $176.10 Payment Date: 07/06/2009 03:43 PM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 07 -06 -2009 Pr ' ct: i f e4: er S I i\ i° T o I I ' o I , Nei. t B dv o La d dress: v S6 4 Date Date Wanted: (A-Z- 1 Y Special Instructions: =r " " i -/2 - 0 p.m. Requester: ... row :* "' ,_,: ... Phone No: _ )7 / 3 45-617 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Daq - 122, PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: -D 242_ — NoJrNo -, r -)L ()P1 AT 1.O k& p i Inspector: Dater -2 0 vs 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pr jest: , . reek t_Q.r Type of Inspection: -Tt rte. r �4, C.� Address: ( 9 60 6 S. C. Al (4 - L Suite #: - 694 (9._ Contact Person: . ,Ve LSfo LA-) . Special Instructions: Phone No.: 96 ---)/ - Kb Needs Shift Inspection: Sprinklers: Fire Alarm: • _ Hood & Duct: Monitor: Pre -Fire: Permits: _ Occupancy Type: INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT proved per applicable codes. INSPECTION RECORD Retain a copy with permit Word /Inspection Record Form.Doc 1/13/06 Poi, I PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa: 98188 _ 206 =575 -4407 ri Corrections required prior to approval. COMMENTS: ,', -c, wA Inspector: I Date: 7/ 7 . rs.. . f $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 S July 8, 2009 Dave Nelson 19419 SE 240 St Covington WA 98042 Department of Community Development Jack Pace, Director RE: Letter of Incomplete Application # 1 Development Permit Application D09 -122 Premier Skin Care — 2800 Southcenter Mall K -9010 Dear Mr. Nelson, Jim Haggerton, Mayor This letter is to inform you that your permit application received at the City of Tukwila Permit Center on July 7, 2009 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department need to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, 41/14'k■Prl Bill Rambo Permit Technician Enclosures File: D09 -122 W:\Permit Center \Incomplete Letters\2009\D09- 122 Incomplete Ltr # I.DOC wer Determination of Completeness Memo Date: July 7, 2009 Project Name: Premier Skin Care Permit #: D09 -122 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The floor plan provided show the new kiosk does not meet code for clearances between other kiosks and maintain the required mall width clearances. Provide a clear floor plan of the mall corridor where the kiosk shall be placed that clearly shows minimum 20 feet horizontal separation between kiosks and other structures within the mall. Also there shall be a minimum 10 feet clear exit width between tenant spaces bordering the mall and the kiosk (both sides). (IBC 402.5.1 & 402.10 # 3.) 2. Plans shall identify type of materials used for the kiosk i.e. fire retardant treated wood complying with IBC Section 2303.2, foam plastics having maximum heat release rate not greater than 100kW (105 Btu/hr) when tested in accordance with the exhibit booth protocol in UL 1975 and Aluminum Composite Materials (ACM) having flame spread index not more than 25 and smoke - developed index not more than 450 per ASTM E84. Please specify type of materials used for this kiosk in compliance code requirements indicated above. (IBC 402.10) Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. DEPARTMENTS: 4?ding 1 1 Division Public Works Complete ❑ Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY% 1 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D09 -122 PROJECT NAME: PREMIER SKIN CARE SITE ADDRESS: 2800 SOUTHCENTER MALL, K Original Plan Submittal Response to Correction Letter # DATE: 07 -16 -09 X Response to Incomplete Letter # 1 Revision # After Permit Issued n Structural ❑ Permit Coordinator ❑ Fire Prevention DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ TUES/THURS ROUTING: Please Route ❑ Structural Review Required n REVIEWER'S INITIALS: 0 DATE: DATE: Planning Division DUE DATE: 07-21-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg El Fire El Ping ❑ PW El Staff Initials: No further Review Required DUE DATE: 08-18-09 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D09 -122 DATE: 07 -06 -09 PROJECT NAME: PREMIER SKIN CARE SITE ADDRESS: 2800 SOUTHCENTER MALL, K -9010 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPART ENTS: • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP kii9 AvA A Fire Prevention ng r'vision Public Works Structural 1) �- w4Al 1 -1-01 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Comments: REVIEWER'S INITIALS: Incomplete DUE DATE: 07-07-09 Permit Center Use Only INCOMPLETE LETTER MAILED: ` S'© 1 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg kr Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route n Structural Review Required ❑ No further Review Required n DATE: jf, Planning Division Permit Coordinator Not Applicable n DUE DATE: 08-04-09 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 DATE: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7-7(--2 Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: l/Lf 1 12 S €/✓ 69Z6 Project Address: p0 5 - 0 vr7/ v am e/ Contact Person: 14-va // [ ovA/ Phone Number: Z6 7/ 7 /b"? Summary of Revision: Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: k ' Entered in Permits Plus on \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: • V1 Plan ChecWPermit Number: U fyr- C � RECEIVED TtiKwilA JUL 1 6 1009 PERMIT CENTER License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DAVIDAN044JH DAVID A GENERNER AL GENERAL CONTR CONSTRUCTION CONTRACTOR GENERAL UNUSED 4/8/1996 10/11 / 1998 ARCHIVED Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 AMERICAN STATES INS CO 6275781 04/05/2004 Until Cancelled $12,000.00 04/08/2004 Name Role Effective Date Expiration Date NELSON, DAVE OWNER 04/08/2004 Amount Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date Untitled Page • S General /Specialty Contractor A business registered as a construction contractor with Lal to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company PREMIER RENOVATIONS 4254139195 19419 SE 240TH ST COVINGTON WA 98042 KING Individual NELDAT INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602691155 ACTIVE PREMIR *963JH CONSTRUCTION CONTRACTOR 4/8/2004 4/8/2010 GENERAL UNUSED Other Associated Licenses Business Owner Information Bond Information Insurance Information Page 1 of 2 https: / /fortress.wa.gov /lni/bbip /Detail. aspx 07/23/2009 11. INFORMATION RELATED TO THE EXISTING CONDITIONS GIVEN HEREIN WAS OBTAINED FROM OWNER PROVIDED DOCUMENTATION AVAILABLE TO THE ARCHITECT AT THE TIME OF DESIGN. THE ACCURACY OF SUCH INFORMATION HAS NOT BEEN VERIFIED. DRAWINGS AND SPECIFICATIONS ARE INTENDED FOR ASSISTANCE AND GUIDANCE, BUT EXACT DIMENSIONS AND ELEVATIONS SHALL BE GOVERNED BY ACTUAL CONDITIONS AT THE SITE AND SHALL BE CHECKED BY THE CONTRACTOR. 12. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL, TELEPHONE, ELECTRICAL (INCLUDING LIGHTING), SECURITY, PLUMBING, AND SPRINKLER WORK TO ENSURE THAT REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE OF ALL EQUIPMENT ARE PROVIDED. WHERE CONFLICTS OCCUR, VERIFY WITH ARCHITECT BEFORE PROCEEDING. 13. WHEN PORTIONS OF THE PROJECT ARE PERFORMED BY THE CONTRACTOR ON A "DESIGN BUILD" BASIS, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE DESIGN OF SUCH SYSTEMS AND FOR THE COORDINATION OF THE DESIGN BUILD SUBCONTRACTORS, WHO SHALL BE THE ENGINEERS OF RECORD FOR SUCH SYSTEM. 14. THE CONTRACTOR SHALL PREPARE, REVIEW, APPROVE, AND SUBMIT TO THE ARCHITECT ALL SHOP DRAWINGS. THE CONTRACTOR SHALL CHECK AND COORDINATE ALL PRODUCT DATA AND SAMPLES AND SHALL VERIFY THAT ALL MATERIALS, FIELD MEASUREMENTS, AND RELATED FIELD CONSTRUCTION CRITERIA CONTAINED WITHIN SUCH SUBMITTALS CONFORMS WITH THE REQUIREMENTS OF THE WORK, THE PROJECT, AND THE CONTRACT DOCUMENTS. THE ARCHITECT WILL NOT REVIEW, APPROVE, OR TAKE OTHER APPROPRIATE ACTION ON SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES UNLESS THE CONTRACTOR HAS SUBMITTED A RECOMMENDATION FOR ACTION. SUBMIT SHOP DRAWINGS, MOCK -UPS SAMPLES, AND OTHER REQUIRED SUBMITTALS IN A TIMELY MANNER SO AS NOT TO DELAY THE PROJECT. ALLOW THE ARCHITECT SUFFICIENT TIME TO REVIEW AND PROCESS ALL SUBMITTALS. 15. THERE SHALL BE NO SUBSTITUTIONS OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED. WHERE THE TERM "OR APPROVED EQUAL" IS USED, THE ARCHITECT ALONE SHALL DETERMINE EQUALITY BASED UPON COMPLETE INFORMATION SUBMITTED BY THE CONTRACTOR. SUBSTITUTIONS SHALL NOT BE MADE UNLESS DRAWINGS AND /OR CUT SHEETS ARE SUBMITTED TO THE ARCHITECT FOR APPROVAL. 16. CONTRACTOR SHALL COORDINATE THE WORK WITH THE TENANT AND BUILDING OWNER SO AS TO MINIMIZE OR ELIMINATE INTERFERENCE WITH ONGOING TENANT OPERATIONS. 17. CONTRACTOR SHALL SCHEDULE AND PERFORM THE WORK DURING NORMAL WORKING HOURS UNLESS OTHERWISE APPROVED BY THE OWNER. 18. THE CONTRACTOR SHALL NOT PROCEED WITH ANY WORK REQUIRING ADDITIONAL COMPENSATION BEYOND THE CONTRACT AMOUNT WITHOUT WRITTEN AUTHORIZATION. FAILURE TO OBTAIN AUTHORIZATION FROM OWNER'S REPRESENTATIVE WILL INVALIDATE ANY CLAIM FOR EXTRA COMPENSATION. 19. SHOULD ANY PORTION OF THE CONTRACT DOCUMENTS PROVE TO BE, FOR WHATEVER REASONS, UNENFORCEABLE, SUCH UNENFORCEABILITY SHALL NOT EXTEND TO THE REMAINDER OF THE CONTRACT NOR SHALL IT VOID ANY OTHER PROVISIONS OF THE CONTRACT. 20. THE CONTRACTOR SHALL PREPARE AND SUBMIT A CONSTRUCTION SCHEDULE FOR THE WORK GIVING APPROXIMATE ON -SITE DELIVERY DATES FOR CONSTRUCTION MATERIALS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY POSSIBLE CONSTRUCTION DELAYS AFFECTING OCCUPANCY THAT MAY ARISE DUE TO THE AVAILABILITY OF SPECIFIED PRODUCTS. 21. SHOP AND FIELD WORK SHALL BE PERFORMED BY MECHANICS, CRAFTSMEN, AND WORKERS SKILLED AND EXPERIENCED IN THE FABRICATION AND INSTALLATION OF THE WORK INVOLVED. WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BEST, ESTABLISHED PRACTICE OF THE INDUSTRY STANDARD FOR THE TRADES INVOLVED. 22. ALL FURNISHED MATERIALS SHALL BE NEW, UNUSED AND OF THE HIGHEST QUALITY IN EVERY RESPECT (U.O.N.). 23. NO WORK DEFECTIVE IN CONSTRUCTION OR QUALITY OR DEFICIENT IN ANY REQUIREMENTS OF THE CONTRACT DOCUMENTS SHALL BE ACCEPTABLE DESPITE THE ARCHITECT'S FAILURE TO DISCOVER OR POINT OUT DEFECTS OR DEFICIENCIES DURING CONSTRUCTION. NO PAYMENT, EITHER PARTIAL OR FINAL, SHALL BE CONSTRUED AS AN ACCEPTANCE OF DEFECTIVE WORK OR IMPROPER MATERIALS. 24. WHEN THE CONTRACTOR BELIEVES THE WORK TO BE SUBSTANTIALLY COMPLETE, THE CONTRACTOR SHALL PREPARE AND SUBMIT TO THE OWNER'S DESIGNATED REPRESENTATIVE A "PUNCH LIST" COMPREHENSIVELY LISTING ALL ITEMS TO BE COMPLETED OR CORRECTED PRIOR TO FINAL PAYMENT. OWNER'S DESIGNATED REPRESENTATIVE MAY SCHEDULE AN INSPECTION TO VERIFY CONDITIONS AT THE SITE AND ACCEPT, REJECT, OR SUPPLEMENT THE PUNCHLIST. 25. CONTRACTOR SHALL INSTALL PRODUCTS AND APPLY FINISHES IN ACCORDANCE WITH MANUFACTURERS' WRITTEN INSTRUCTIONS AND SPECIFICATIONS, UNLESS DIRECTED OTHERWISE BY ARCHITECT. 26. ALL INSTALLED PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT SHALL OPERATE QUIETLY, SMOOTHLY AND FREE OF VIBRATION. SEE MANUFACTURER'S RECOMMENDATIONS FOR ACOUSTICALLY SOUND CONSTRUCTION METHODS. 27. ALL NEW CONSTRUCTION SHALL MATCH THE ESTABLISHED EXISTING BUILDING STANDARD UNLESS OTHERWISE NOTED. 28. DO A COMPLETE JOB. PROVIDE ALL ACCESSORIES AND INCIDENTALS NECESSARY FOR A COMPLETE JOB COMPLYING WITH CODES AND REGULATIONS. 29. IF MECHANICAL, ELECTRICAL, PLUMBING, OR FIRE PROTECTION, OR OTHER WORK IS BY THE DESIGN -BUILD METHOD, CONTRACTOR SHALL EMPLOY AS PART OF ITS BASIC WORK, ENGINEERS PROPERLY QUALIFIED AND LICENSED TO DESIGN THE WORK IN QUESTION. ANY ARCHITECTURAL DRAWINGS THAT INDICATE LOCATIONS OF MECHANICAL, ELECTRICAL, PLUMBING, OR FIRE PROTECTION WORK ARE FOR GENERAL LOCATION AND COORDINATION WITH ARCHITECTURAL WORK ONLY. THE ENGINEERING DETAILS OF THESE SYSTEMS SHALL BE DESIGNED BY THE DESIGN -BUILD CONTRACTOR AND FULLY SHOWN ON ENGINEERING DESIGN -BUILD DRAWINGS WHICH SHALL GOVERN SUCH WORK. - DEFINITIONS - 1. "TYPICAL" OR "TYP" MEANS IDENTICAL FOR ALL SIMILAR CONDITIONS, UNLESS OTHERWISE NOTED. 2. "SIMILAR" MEANS COMPARABLE TO CHARACTERISTICS FOR THE CONDITION NOTED. VERIFY DIMENSIONS AND ORIENTATION ON PLAN. 3. "AS REQUIRED" MEANS AS REQUIRED BY REGULATORY REQUIREMENTS, BY REFERENCED STANDARDS, BY EXISTING CONDITIONS, BY GENERALLY ACCEPTED CONSTRUCTION PRACTICE, OR BY THE CONTRACT DOCUMENTS. 4. "ALIGN" MEANS ACCURATELY LOCATE FINISH FACES OF MATERIALS IN SAME PLANE. 5. "PROVIDE " MEANS FURNISH AND INSTALL. 6. "FURNISH" OR "FURNISH ONLY " MEANS CONTRACTOR SHALL FURNISH THE ITEM FOR INSTALLATION BY OWNER. 7. "INSTALL" OR "INSTALL ONLY " MEANS CONTRACTOR SHALL INSTALL ALL THE ITEMS FURNISHED BY OWNER. 8. "ADD" MEANS FURNISH AND INSTALL - DIMENSIONS - 1. HORIZONTAL DIMENSIONS ARE SHOWN FROM FACE OF SCHEDULED PARTITION TO FACE OF SCHEDULED PARTITION INCLUDING FINISH MATERIALS. 2. ALL HEIGHTS ARE DIMENSIONED FROM TOP OF EXISTING SLAB UNLESS NOTED "A.F.F." (ABOVE FINISHED FLOOR). 3. DIMENSIONS ARE NOT ADJUSTABLE, UNLESS NOTED ( + / -), WITHOUT THE ARCHITECT'S WRITTEN APPROVAL. 4. DO NOT SCALE DRAWINGS; DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS AND ELEVATIONS. LARGE SCALE PLANS SHALL GOVERN OVER SMALL SCALE PLANS. LARGE SCALE DETAILS SHALL GOVERN OVER SMALL SCALE DETAILS. IF UNABLE TO LOCATE DIMENSIONS FOR ANY ITEM OF WORK, CONSULT THE ARCHITECT PRIOR TO CONSTRUCTION. 1. THE CONTRACT FOR CONSTRUCTION SHALL INCLUDE THE FOLLOWING PORTIONS OF AIA DOCUMENT A 201, GENERAL CONDITIONS OF THE CONSTRUCTION, 1997 EDITION: ARTICLE 1, ARTICLE 2, ARTICLE 3 SECTION 4.1, SECTION 4.3, SECTION 4.5, SECTION 4.6 ARTICALES 5 THROUGH ARTICLE 8 ARTICLES 10 THROUGH ARTICLE 14 2. THE CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK AT ANY TIME WITHOUT ALL NECESSARY PERMITS ISSUED BY ALL REGULATORY AUTHORITIES HAVING JURISDICTION. 3. THE CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK AT AT ANY TIME WITHOUT CONTRACT DOCUMENTS OR, WHERE REQUIRED, APPROVED SHOP DRAWINGS, DESIGN -BUILT PRODUCT DATA, OR SAMPLE FOR SUCH PORTION OF THE WORK. 4. THE CONTRACTOR SHALL PERFORM THE WORK IN ACCORDANCE WITH ALL LAWS, CODES, ORDINANCES, RULES, AND REGULATIONS OF ALL GOVERNING AGENCIES. 5. THE CONTRACTOR AND SUBCONTRACTORS SHALL PURCHASE AND MAINTAIN INSURANCE WITH RESPECT TO WORKERS COMPENSATION, PUBLIC LIABILITIES, AND PROPERTY DAMAGE FOR THE LIMITS REQUIRED BY LAW. INSURANCE SHALL NAME OWNER, ARCHITECTURAL FIRM AND THIER EMPLOYEES AS ADDITIONALLY INSURED. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK. 7. THROUGHOUT THE DURATION OF THE PROJECT, THE CONTRACTOR SHALL REFRAIN FROM ACTIONS THAT COULD LEAD TO THE FILING OF A CLAIM OR LIEN AGAINST THE PROJECT BY SUB - CONTRACTORS OR SUPPLIERS OF MATERIALS, LABOR, SERVICE OR EQUIPMENT OR ANY OTHER INDIVIDUAL OR COMPANY SO ENTITLED UNDER GOVERNING LAWS AND REGULATIONS UNLESS HE CAN SHOW REASONABLE AND JUSTIFIABLE CAUSE. APPROVAL FOR FINAL PAYMENT SHALL BE CONTINGENT UPON THE CONTRACTOR'S OBTAINING AND FURNISHING TO THE OWNER SIGNED RELEASES FROM SUCH INDIVIDUALS OR COMPANIES. 8. THE CONTRACTOR SHALL CONFINE OPERATIONS AT THE SITE TO AREAS PERMITTED BY LAW, ORDINANCES, PERMITS AND THE CONTRACT DOCUMENTS. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING CONTRACT DOCUMENTS, FIELD CONDITIONS, AND DIMENSIONS FOR ACCURACY AND FOR CONFIRMING THAT THE PROJECT IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH THE CONSTRUCTION. IF THERE ARE ANY QUESTIONS REGARDING THESE OR OTHER COORDINATION QUESTIONS, THE CONTRACTOR SHALL SUBMIT THEM, IN WRITING TO THE ARCHITECT AND CONTRACTOR IS RESPONSIBLE FOR OBTAINING A WRITTEN CLARIFICATION FORM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK IN QUESTION OR RELATED WORK. 10. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED TO COMPLETE THE PROJECT UNLESS SPECIFIED OTHERWISE. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. MOTE: Revisions will require a new plan submittal and may Inrl fide addit:ona! plan review i t DRAWING TITLE O TITLE LINE TYPES - -- ---- PROPERTY LINE FLOOR ELEVATION SYMBOLS HEIGHT ABOVE NOMINAL FLOOR ELEVATION ELEVATION REFERENCE SYMBOL A SECTION REFERENCE SYMBOL CENTERLINE DETAIL REFERENCE SYMBOL I. PROJECT ADDRESS: 633 SOUTHCENTER, SEATTLE, WA 98188 SPACE # 9010 2. EXISTING BUILDING DESCRIPTION A. EXISTING BUILDING OCCUPANCY GROUP: M B. EXISTING CONSTRUCITON TYPE: 1 / FULLY SPRINKLERED C. EXISTING AUTOMATIC SPRINKLERS: YES D. EXSITING HEIGHT: 1 STORIES 3. THIS PROJECT (TENANT IMPROVEMENT ) A. ADD 150 SF OF MILLWORK AND CASEWORK IN THE EXISTING MALL TO CREATE A NEW KIOSK FOR SELLING SKIN CARE PRODUCTS. B. OCCUPANCY GROUP: M BLDG. AREA = COLUMN and /or GRID LINES DRAWING DETAIL AND REFERENCE SYMBOL L ANGLE (a� AT CENTERLINE C CHANNEL 0 DIAMETER OR ROUND L PERPENDICULAR OR STRUCTURAL TEE [I] SQUARE FOOT (FEET) (A -504 -B OFFICE A -211 DETAIL IDENTIFICATION SHEET SEQUENCE NUMBER FLOOR LEVEL NUMBER SHEET TYPE DESIGNATOR DISCLIPLINE DESIGNATOR SPACE NAME SPACE NUMBER 1 1 INDICATES FINISHED SURFACES 1 T TO ALIGN 4. ALLOWABLE AREA CALCULATIONS (NOT APPLICABLE -NO CHANGE TO EXISTING BUILDING AREA) 5. CITY CODES: SEATTLE, WA INCLUDING AND AND ALL APPLICABLE LOCAL, STATE, FEDERAL LAWS AND REGULATIONS FILE COPY Permit No. '" ` Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of arjyjadopted code or ordinance. Receipt of approved Fi, + �y r. ,� is • t . ., •ed: By Date: . 7- - City Of lbkwila BUILDING DIVISION • : � �n► I .... 771 i SEPARATE PERMIT REQUIRED FOR: LIM • hanical � rE / tPCtrical C iii bing Comas Piping City of Tukwila WADING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 1 2009 Cit of Tukwlia BUILDING DIVISION ARCHITECTURAL ISSUE NUMBER A -001 A -002 A -101 A -201 A -202 A -203 A -204 DESCRIPTION COVER SHEET & GENERAL PROJECT INFORMATION SITE PLAN & VICINITY PLAN FLOATING ELEVATIONS UNIT 1 CONSTRUCTION DWG UNIT 2 CONSTRUCTION DWG UNIT 3 CONSTRUCTION DWG PYLON CONSTRUCTION DWG TENANT: PROJECT MANAGEMENT: ARCHITECTS ENGINEERS GENERAL CONTRACTOR PREMIER SKIN CARE THE PLASTIC MAN 3919 RENATE DRIVE LAS VEGAS, NEVADA 89103 JESUS LAYVA CELL: 702.818.6632 RECEIVED CITY OF TUKWILA JUL 1`, 2009 PERMIT CENTER INCOMPLETE LT # , I P0 RETAIL KIOSK SOUTHCENTER MALL 633 SOUTHCENTER SEATTLE, WA 98188 (Contractor Identification & Seals) INTERNAL DRAFT AND NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY LICENSED PROFESSIONAL ARCHITECT OR ENGINEER. ARCHITECTURAL STAMP AND SIGNATURE APPLIES ONLY TO ARCHITECTURAL PORTION OF DRAWINGS; NOT MECHANICAL, ELECTRICAL, STRUCTURAL, CIVIL, FIRE PROTECTION, OR ENGINEERING DISCIPLINE. ARCHITECT IS RESPONSIBLE FOR ARCHITECTURAL WORKS ONLY. ENGINEERING DISCIPLINES ARE RESPONSIBLE FOR ALL ENGINEERING WORK. ISSUED NO. REVISIONS NO. A A A A A A A DESCRIPTION DESCRIPTION PROJECT NO: SHEET TITLE: SCALE: Cover Sheet & General Project I nformation DATE DATE 7 SHEET NO: Aso 0 0 I FMOxl5 Seade\Phadmman - 1 0x15 Cover Sheecdwg FINISH SCHEDULE (Contractor Identification & Seals) INTERNAL DRAFT AND NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY LICENSED PROFESSIONAL ARCHITECT OR ENGINEER. ARCHITECTURAL STAMP AND SIGNATURE APPLIES ONLY TO ARCHITECTURAL PORTION OF DRAWINGS; NOT MECHANICAL, ELECTRICAL, STRUCTURAL, CIVIL, FIRE PROTECTION, OR ENGINEERING DISCIPLINE. ARCHITECT IS RESPONSIBLE FOR ARCHITECTURAL WORKS ONLY. ENGINEERING DISCIPLINES ARE RESPONSIBLE FOR ALL ENGINEERING WORK. FORMICA 9012 -N1 "EBONY NATURELE FINISH" 0 CHEMETAL, #909 "SATIN SILVER ALUMINUM" 0 FORMICA 932 -58 "ANTIQUE WHITE" ® NONE ® BEL AIR B "x STAINED BLACK BAMBOO VERTICAL 0 FORMICA 932 -58 "ANTIQUE WHITE" ® 8" SAFETY GLASS 0 MIRROR F. \10x15 Searle PIastiaaan - 10x15 Cover Sheetdwg SO LEVEL Is FRAGRANCE COSMETICS MEN9 SHOES WOMEN'S SHOES MEWS FUPNISHINGS LIENS SPORTSWEAR JEWELRY LEVEL WOMEN'S APPAREL JUNIORS APPAREL LEVEL 9: NORDSTROM CAFE nos SHOES PETITE APPAREL ONS➢REN/TCOOLERSANFANr CLOTHING CUSTOMER SERVICE NORDSTROM V THREE LEVELS 0S r< LOCAT O The document is diagrammatic and is intended only to show the demised premises of the project (hatched area.) it does not purport to show exact dimensions nor the final locution of any mechunicel, electrical, structural or architectural element. Further, the iendlord reserves the right to odd, eliminate or modify any such element, no -TR C V SCALE: NTS C ti FRANKLIN COVEY YFRIZou 1WRQ.ESS =W \ ITY VAP f. SCALE: NOT TO SCALE E I g I6 v SANK A TiC IATM2I EMI SCALE: NOT TO SCALE mE PF.l1FiF.r { • kBEomCIi6:E Kara f.H + W LEVEL Is INTIMATE APPAREL JIIORS APPAREL LUD8 WOMEN 1424 YOUNG MENS LEVEL 2: COSMETICS S FRAGRANCE ACCESSORIES JEWELRY HOSIERY LENS CLOTHSIG LENS SHOES YNLENS SHOES LEVEL 3: DRESSES PETRIS VAD ENS APPAREL LEVEL 4: RED N BATH BRIDAL a CHI - AL ARES MATTRESSES LIFT WRAP macys FOUR LEVELS MOM. cusTOMEIl n kl may be required from time to time. Tenant space_ dimensions, unless otherwise noted are to the centerlines of tenant partitions and calarrrn yids, face of exterior wails and to the outside face of service area partitions adjacent to the tenant space (siz. corridors, closets, and stairs.) V 200 N 1211 rI566i m'4(LVi 00324 I YATNDI - ®® ® 1 576 I ® k 5 a i 6 6 e L� GOIRMA 12041 556 1 0 0 500 INTERNALLY ILLUMINATED DISPLAYS OS LOCAT O\ PLA\ SCALE: 1 /4 " =1 –0" 120V ©60W FOR LTG N 12" INTERNALLY ILLUMINATED DISPLAY 48" 120V ©60W O FOR LTG A 24" FLOOR PLA\ SCALE: 1 /2 " =1 ' -0" 36" ADA RAMP 58" —.4-* _- 36" 15-0" X64 ■ 43" 29" UNIT 2 UNIT 3 12" H 60 1/2" TMm (1) 120V ©80W INTERNALLY \\ ILLUMINATED PYLON 120V ©60W FOR LTG INTERNALLY -- ILLUMINATED DISPLAYS / / ELECTRICAL NOTES: 1. ALL RECEPTACLE OUTLETS TO BE GROUNDED & GFI PROTECTED 2. LIGHTING INSIDE DISPLAY CASES & PYLON TO BE LUXEMBRIGHT LED SYSTEM. C A A X 0 9 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 1 2009 City of Tukwila BUILDING DIVISION GENERAL NOTES: 1. MIRRORS ARE SILICONED INTO OPENINGS. 2. UNITS 1, 2 & 3 HAVE LOCKING SLIDING DOORS. 3. ALL UNITS OVER 48" TALL WILL BE ANCHORED DOWN TO EXISTING SLAB WITH 2" ANCHOR BOLTS IN ALL CORNERS OF BASE. 4. PLATFORM IS 2" RAISED FLOORING, WITH " ANCHOR BOLTS IN ALL FOUR CORNERS. 5. ALL WOOD MATERIAL IS i" FORMALDEHYDE FREE, FIRE RETARDANT MEDIUM DENSITY FIBERBOARD (MDF) PANELS (CLASS 1 A, COMBUSTIBLE MATERIAL) FLAME SPREAD 20, SMOKE DEVELOPED 100 RECEIVED CITY OF TUKWILA JUL 16 2009 PERMIT CENTER RETAIL KIOSK SOUTHCENTER MALL 633 SOUTHCENTER SEATTLE, WA 98188 (Contractor Identification & Seals) INTERNAL DRAFT AND NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY LICENSED PROFESSIONAL ARCHITECT OR ENGINEER. ARCHITECTURAL STAMP AND SIGNATURE APPLIES ONLY TO ARCHITECTURAL PORTION OF DRAWINGS; NOT MECHANICAL, ELECTRICAL, STRUCTURAL, CIVIL, FIRE PROTECTION, OR ENGINEERING DISCIPLINE. ARCHITECT IS RESPONSIBLE FOR ARCHITECTURAL WORKS ONLY. ENGINEERING DISCIPLINES ARE RESPONSIBLE FOR ALL ENGINEERING WORK. ISSUED NO. DESCRIPTION DATE REVISIONS NO. DESCRIPTION DATE A A A A A A A A A A A PROJECT NO: SCALE: SHEET TITLE: LOCATION SHEET NO: Anse 0 02 F. \10x15 Searle PIastiaaan - 10x15 Cover Sheetdwg SO LEVEL Is FRAGRANCE COSMETICS MEN9 SHOES WOMEN'S SHOES MEWS FUPNISHINGS LIENS SPORTSWEAR JEWELRY LEVEL WOMEN'S APPAREL JUNIORS APPAREL LEVEL 9: NORDSTROM CAFE nos SHOES PETITE APPAREL ONS➢REN/TCOOLERSANFANr CLOTHING CUSTOMER SERVICE NORDSTROM V THREE LEVELS 0S r< LOCAT O The document is diagrammatic and is intended only to show the demised premises of the project (hatched area.) it does not purport to show exact dimensions nor the final locution of any mechunicel, electrical, structural or architectural element. Further, the iendlord reserves the right to odd, eliminate or modify any such element, no -TR C V SCALE: NTS C ti FRANKLIN COVEY YFRIZou 1WRQ.ESS =W \ ITY VAP f. SCALE: NOT TO SCALE E I g I6 v SANK A TiC IATM2I EMI SCALE: NOT TO SCALE mE PF.l1FiF.r { • kBEomCIi6:E Kara f.H + W LEVEL Is INTIMATE APPAREL JIIORS APPAREL LUD8 WOMEN 1424 YOUNG MENS LEVEL 2: COSMETICS S FRAGRANCE ACCESSORIES JEWELRY HOSIERY LENS CLOTHSIG LENS SHOES YNLENS SHOES LEVEL 3: DRESSES PETRIS VAD ENS APPAREL LEVEL 4: RED N BATH BRIDAL a CHI - AL ARES MATTRESSES LIFT WRAP macys FOUR LEVELS MOM. cusTOMEIl n kl may be required from time to time. Tenant space_ dimensions, unless otherwise noted are to the centerlines of tenant partitions and calarrrn yids, face of exterior wails and to the outside face of service area partitions adjacent to the tenant space (siz. corridors, closets, and stairs.) V 200 N 1211 rI566i m'4(LVi 00324 I YATNDI - ®® ® 1 576 I ® k 5 a i 6 6 e L� GOIRMA 12041 556 1 0 0 500 INTERNALLY ILLUMINATED DISPLAYS OS LOCAT O\ PLA\ SCALE: 1 /4 " =1 –0" 120V ©60W FOR LTG N 12" INTERNALLY ILLUMINATED DISPLAY 48" 120V ©60W O FOR LTG A 24" FLOOR PLA\ SCALE: 1 /2 " =1 ' -0" 36" ADA RAMP 58" —.4-* _- 36" 15-0" X64 ■ 43" 29" UNIT 2 UNIT 3 12" H 60 1/2" TMm (1) 120V ©80W INTERNALLY \\ ILLUMINATED PYLON 120V ©60W FOR LTG INTERNALLY -- ILLUMINATED DISPLAYS / / ELECTRICAL NOTES: 1. ALL RECEPTACLE OUTLETS TO BE GROUNDED & GFI PROTECTED 2. LIGHTING INSIDE DISPLAY CASES & PYLON TO BE LUXEMBRIGHT LED SYSTEM. C A A X 0 9 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 1 2009 City of Tukwila BUILDING DIVISION GENERAL NOTES: 1. MIRRORS ARE SILICONED INTO OPENINGS. 2. UNITS 1, 2 & 3 HAVE LOCKING SLIDING DOORS. 3. ALL UNITS OVER 48" TALL WILL BE ANCHORED DOWN TO EXISTING SLAB WITH 2" ANCHOR BOLTS IN ALL CORNERS OF BASE. 4. PLATFORM IS 2" RAISED FLOORING, WITH " ANCHOR BOLTS IN ALL FOUR CORNERS. 5. ALL WOOD MATERIAL IS i" FORMALDEHYDE FREE, FIRE RETARDANT MEDIUM DENSITY FIBERBOARD (MDF) PANELS (CLASS 1 A, COMBUSTIBLE MATERIAL) FLAME SPREAD 20, SMOKE DEVELOPED 100 RECEIVED CITY OF TUKWILA JUL 16 2009 PERMIT CENTER RETAIL KIOSK SOUTHCENTER MALL 633 SOUTHCENTER SEATTLE, WA 98188 FINISH SCHEDULE 0 FORMICA 9012 -N1 "EBONY NATURELE FINISH" ® CHEMETAL #909 "SATIN SILVER ALUMINUM" DATE FORMICA "ANTIQUE 932 -58 WHITE" ® NONE 0 BEL AIR STAINED 8" x 3 i" BLACK BAMBOO VERTICAL 0 FORMICA "ANTIQUE 932 -58 WHITE" ® 8" SAFETY GLASS 0 MIRROR F. \IOxI5 Seada Tindal= - 10x15 Layoutdwg GLASS DISPLAY BEYOND MINI PYLON BEYOND MINI PYLON DISPLAY CABINET BASE BACKLIT PYLON PYLON BASE GENERAL NOTES: 1. MIRRORS ARE SILICONED INTO OPENINGS. 2. UNITS 1, 2 & 3 HAVE LOCKING SLIDING DOORS. 3. ALL UNITS OVER 48" TALL WILL BE ANCHORED DOWN TO EXISTING SLAB WITH 4 ANCHOR BOLTS IN ALL CORNERS OF BASE. 4. PLATFORM IS 2" RAISED FLOORING, WITH i" ANCHOR BOLTS IN ALL FOUR CORNERS. 5. ALL WOOD MATERIAL IS i" FORMALDEHYDE FREE, FIRE RETARDANT MEDIUM DENSITY FIBERBOARD (MDF) PANELS (CLASS 1 A, COMBUSTIBLE MATERIAL) FLAME SPREAD 20, SMOKE DEVELOPED 100 ELECTRICAL NOTES: 1. ALL RECEPTACLE OUTLETS TO BE GROUNDED & GFI PROTECTED 2. LIGHTING INSIDE DISPLAY CASES & PYLON TO BE LUXEMBRIGHT LED SYSTEM. f LEFT ELEVATION L 27" MINI PYLON BEYOND SCALE: 1"=1'-0" / SCALE: 1"=1'-0" RIGHT ELEVATION / / / / DISPLAY CASE BEYOND GLASS CASE BEYOND CD In 18" 7- 27" 21" 0 MINI PYLON N N PYLON BEYOND GLASS DISPLAY CASE BASE GLASS DISPLAY CASE MINI PYLON W/ 3D LOGO DISPLAY BASE CABINET BASE GLASS DISPLAY BEYOND MINI PYLON BEYOND DISPLAY CABINET BASE PYLON BEYOND DISPLAY BASE CABINET BASE 03 In 1 00 5" / / 1 6" 12" / / / / aw- f FRONT ELEVATION 29" 12" SCALE: 1 " =1' —O" BACK ELEVATION DISPLAY CASE BEYOND DISPLAY CASE BEYOND SCALE: 1 " =1' —O" — LOCKING DOORS In N DISPLAY CABINET 60 7/16" DO 27" rem er 0 18" REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 1 2009 City of Tukwila BUILDING DIVISION 5" MINI PYLON W/ 3D LOGO N PYLON 3D LOGO BASE 00 GLASS DISPLAY CASE DISPLAY BASE CABINET BASE RECEIVED CITY OF TUKWIIA JUL 1'6 1009 PERMIT CENTER RETAIL KIOSK SOUTHCENTER MALL 633 SOUTHCENTER SEATTLE, WA 98188 ( Contractor Identification & Seals) INTERNAL DRAFT AND NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY LICENSED PROFESSIONAL ARCHITECT OR ENGINEER. ARCHITECTURAL STAMP AND SIGNATURE APPLIES ONLY TO ARCHITECTURAL PORTION OF DRAWINGS; NOT MECHANICAL, ELECTRICAL, STRUCTURAL, CIVIL, FIRE PROTECTION, OR ENGINEERING DISCIPLINE. ARCHITECT IS RESPONSIBLE FOR ARCHITECTURAL WORKS ONLY. ENGINEERING DISCIPLINES ARE RESPONSIBLE FOR ALL ENGINEERING WORK. ISSUED NO. DESCRIPTION DATE REVISIONS NO. DESCRIPTION DATE A A A A A A A A A A A PROJECT NO: SCALE: SHEET TITLE: FLOATING ELEVATIONS SHEET NO: Amami 0 1 F. \IOxI5 Seada Tindal= - 10x15 Layoutdwg GLASS DISPLAY BEYOND MINI PYLON BEYOND MINI PYLON DISPLAY CABINET BASE BACKLIT PYLON PYLON BASE GENERAL NOTES: 1. MIRRORS ARE SILICONED INTO OPENINGS. 2. UNITS 1, 2 & 3 HAVE LOCKING SLIDING DOORS. 3. ALL UNITS OVER 48" TALL WILL BE ANCHORED DOWN TO EXISTING SLAB WITH 4 ANCHOR BOLTS IN ALL CORNERS OF BASE. 4. PLATFORM IS 2" RAISED FLOORING, WITH i" ANCHOR BOLTS IN ALL FOUR CORNERS. 5. ALL WOOD MATERIAL IS i" FORMALDEHYDE FREE, FIRE RETARDANT MEDIUM DENSITY FIBERBOARD (MDF) PANELS (CLASS 1 A, COMBUSTIBLE MATERIAL) FLAME SPREAD 20, SMOKE DEVELOPED 100 ELECTRICAL NOTES: 1. ALL RECEPTACLE OUTLETS TO BE GROUNDED & GFI PROTECTED 2. LIGHTING INSIDE DISPLAY CASES & PYLON TO BE LUXEMBRIGHT LED SYSTEM. f LEFT ELEVATION L 27" MINI PYLON BEYOND SCALE: 1"=1'-0" / SCALE: 1"=1'-0" RIGHT ELEVATION / / / / DISPLAY CASE BEYOND GLASS CASE BEYOND CD In 18" 7- 27" 21" 0 MINI PYLON N N PYLON BEYOND GLASS DISPLAY CASE BASE GLASS DISPLAY CASE MINI PYLON W/ 3D LOGO DISPLAY BASE CABINET BASE GLASS DISPLAY BEYOND MINI PYLON BEYOND DISPLAY CABINET BASE PYLON BEYOND DISPLAY BASE CABINET BASE 03 In 1 00 5" / / 1 6" 12" / / / / aw- f FRONT ELEVATION 29" 12" SCALE: 1 " =1' —O" BACK ELEVATION DISPLAY CASE BEYOND DISPLAY CASE BEYOND SCALE: 1 " =1' —O" — LOCKING DOORS In N DISPLAY CABINET 60 7/16" DO 27" rem er 0 18" REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 1 2009 City of Tukwila BUILDING DIVISION 5" MINI PYLON W/ 3D LOGO N PYLON 3D LOGO BASE 00 GLASS DISPLAY CASE DISPLAY BASE CABINET BASE RECEIVED CITY OF TUKWIIA JUL 1'6 1009 PERMIT CENTER RETAIL KIOSK SOUTHCENTER MALL 633 SOUTHCENTER SEATTLE, WA 98188 FINISH SCHEDULE 0 FORMICA 9012 —N1 "EBONY NATURELE FINISH" �s CHEMETAL #909 "SATIN SILVER ALUMINUM" @ FORMICA "ANTIQUE 932 -58 WHITE" 0 NONE ® BEL AIR $" x 3 $" STAINED BLACK BAMBOO VERTICAL 0 FORMICA "ANTIQUE 932 -58 WHITE" 0 8" SAFETY GLASS MIRROR F \10x15 Seale \P o an - 10x15 Layoutdwg 48" UNIT 2 —1 6" .... KIOSK KEY PLAN SCALE: 1 /2 " =1' -0" DISPLAY CABINET BASE Lc) 10 29 UNIT 2 I UNIT 3 60 1 /2" / / / 1 6" 1 co N LEFT ELEVATION SCALE: 1 " =1' -0" In UNIT 1 PLAN VIEW GENERAL NOTES: 1. MIRRORS ARE SILICONED INTO OPENINGS. 2. UNITS 1, 2 & 3 HAVE LOCKING SLIDING DOORS. 3. ALL UNITS OVER 48" TALL WILL BE ANCHORED DOWN TO EXISTING SLAB WITH 2 " ANCHOR BOLTS IN ALL CORNERS OF BASE. 4. PLATFORM IS 2" RAISED FLOORING, WITH 2" ANCHOR BOLTS IN ALL FOUR CORNERS. 5. ALL WOOD MATERIAL IS i" FORMALDEHYDE FREE, FIRE RETARDANT MEDIUM DENSITY FIBERBOARD (MDF) PANELS (CLASS 1 A, COMBUSTIBLE MATERIAL) FLAME SPREAD 20, SMOKE DEVELOPED 100 ELECTRICAL NOTES: 1. ALL RECEPTACLE OUTLETS TO BE GROUNDED & GFI PROTECTED 2. LIGHTING INSIDE DISPLAY CASES & PYLON TO BE LUXEMBRIGHT LED SYSTEM. SCALE: 1 " =1' -0" FRONT ELEVATION SCALE: 1 " =1' -0" MINI PYLON W/ VINYL GRAPHIC GLASS DISPLAY CASE BASE DISPLAY CABINET BASE rn tO GRAPHIC VINYL W/ LOGO 1 6" 12" / / / 16" i PM- SCALE: 1 " =1' -0" FRONT ISOMETRIC SCALE: NTS / 12" / 24" / / / SCALE: 1"=1'-0" 12" RIGHT ELEVATION _ BACK ELEVATION / / i i MINI PYLON BACK ISOMETRIC GLASS DISPLAY CASE Ln BASE SCALE: NTS 0 Iz REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 1 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF 1 UKW1LA JUL 16 2009 PERMIT CENTER RETAIL KIOSK SOUTHCENTER MALL 633 SOUTHCENTER SEATTLE, WA 98188 (Contractor Identification & Seals) INTERNAL DRAFT AND NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY LICENSED PROFESSIONAL ARCHITECT OR ENGINEER. ARCHITECTURAL STAMP AND SIGNATURE APPLIES ONLY TO ARCHITECTURAL PORTION OF DRAWINGS; NOT MECHANICAL, ELECTRICAL, STRUCTURAL, CIVIL, FIRE PROTECTION, OR ENGINEERING DISCIPLINE. ARCHITECT IS RESPONSIBLE FOR ARCHITECTURAL WORKS ONLY. ENGINEERING DISCIPLINES ARE RESPONSIBLE FOR ALL ENGINEERING WORK. ISSUED NO. REVISIONS NO. A A A A A A A A A A A PROJECT NO: SHEET TITLE: SHEET NO: A,..,2 0 DESCRIPTION DESCRIPTION SCALE: DATE DATE UNIT 'I CONSTRUCTION DWG FINISH SCHEDULE (Contractor Identification & Seals) INTERNAL DRAFT AND NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY LICENSED PROFESSIONAL ARCHITECT OR ENGINEER. ARCHITECTURAL STAMP AND SIGNATURE APPLIES ONLY TO ARCHITECTURAL PORTION OF DRAWINGS; NOT MECHANICAL, ELECTRICAL, STRUCTURAL, CIVIL, FIRE PROTECTION, OR ENGINEERING DISCIPLINE. ARCHITECT IS RESPONSIBLE FOR ARCHITECTURAL WORKS ONLY. ENGINEERING DISCIPLINES ARE RESPONSIBLE FOR ALL ENGINEERING WORK. FORMICA 9012 -N1 "EBONY NATURELE FINISH" 0 CHEMETAL #909 "SATIN SILVER ALUMINUM" @ FORMICA "ANTIQUE 932 -58 WHITE" NONE 0 BEL AIR STAINED g" x 3 8" BLACK BAMBOO VERTICAL 0 FORMICA "ANTIQUE 932 -58 WHITE" ® ,' SAFETY GLASS 0 MIRROR FAIOxl5 SeatlelPlastianan - I Ox I 5 layoucdwg co 2 48" UNIT 2 -.16" KIOSK KEY PLAN SCALE: 1 /2 " =1 ' -0" 29" / 12" 7 „ LEFT ELEVATION SCALE: 1"=1'-0" — 29" UNIT 2 I UNIT 3 60 1/2" oo M MINI PYLON DISPLAY CABINET BASE to T 05" TRASH RECEPTACLE �. (0 N c0 It) GLASS DISPLAY CASE IS "FRAMELESS SILICONED APPLICATION." (TYP) M N F' () M A 18" UNIT 2 N PLAN VIEW H18" 27" / / / / i / / / / , / 48" N 9" GENERAL NOTES: 1. MIRRORS ARE SILICONED INTO OPENINGS. 2. UNITS 1, 2 & 3 HAVE LOCKING SLIDING DOORS, 3. ALL UNITS OVER 48" TALL WILL BE ANCHORED DOWN TO EXISTING SLAB WITH i" ANCHOR BOLTS IN ALL CORNERS OF BASE. 4. PLATFORM IS 2" RAISED FLOORING, WITH 2" ANCHOR BOLTS IN ALL FOUR CORNERS. 5. ALL WOOD MATERIAL IS i" FORMALDEHYDE FREE, FIRE RETARDANT MEDIUM DENSITY FIBERBOARD (MDF) PANELS (CLASS 1 A, COMBUSTIBLE MATERIAL) FLAME SPREAD 20, SMOKE DEVELOPED 100 ELECTRICAL NOTES: 1. ALL RECEPTACLE OUTLETS TO BE GROUNDED & GFI PROTECTED 2. LIGHTING INSIDE DISPLAY CASES & PYLON TO BE LUXEMBRIGHT LED SYSTEM. 30 ,21" SCALE: 1"=1'-0" .. 30" , , 21" OJI ==1 2 FRONT ELEVATION SCALE: 1"=1'-0" t N LUXEMBRIGHT LED SYSTEM MOUNTED INSIDE CABINET. „ MINI PYLON W/ 3D LOGO DISPLAY BASE CABINET - = f BASE MINI PYLON DISPLAY CABINET BASE 12” to I) 2 29" QUANTITY: 2 RIGHT ELEVATION SCALE: 1"=1 '-0" M FRONT ISOMETRIC SCALE: NTS LUXEMBRIGHT LED SYSTEM MOUNTED INSIDE CABINET. 21" MINI PYLON W/ 3D LOGO BASE cc M O —\ — SLIDING GLA OPEN 27" BACK ELEVATION SCALE: 1"=1'-0" BACK ISOMETRIC S DOORS.. ,\ 18" �I SCALE: NTS GLASS DISPLAY CASE IS "FRAMELESS SILICONED APPLICATION." (TYP) c0 M C.R. LAWRENCE CHROME SLIDING DOOR TRACKS. (TYP TOP & BOTTOM) C.R. LAWRENCE PUSH LOCKS. (TYP) OVERLAY DOORS, WITH PUSH LATCH & EURO HINGES. D09- (21 REVIEWED FOR CODE COMPLIANCE APPROVED J.L. 2 1 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 16 2009 PERMIT CENTER RETAIL KIOSK SOUTHCENTER MALL 633 SOUTHCENTER SEATTLE, WA 98188 (Contractor Identification & Seals) INTERNAL DRAFT AND NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY LICENSED PROFESSIONAL ARCHITECT OR ENGINEER. ARCHITECTURAL STAMP AND SIGNATURE APPLIES ONLY TO ARCHITECTURAL PORTION OF DRAWINGS; NOT MECHANICAL, ELECTRICAL, STRUCTURAL, CIVIL, FIRE PROTECTION, OR ENGINEERING DISCIPLINE. ARCHITECT IS RESPONSIBLE FOR ARCHITECTURAL WORKS ONLY. ENGINEERING DISCIPLINES ARE RESPONSIBLE FOR ALL ENGINEERING WORK. ISSUED NO. DESCRIPTION DATE REVISIONS NO. DESCRIPTION DATE A A A A A A A A A A A PROJECT NO: SCALE: SHEET TITLE: UNIT 2 CONSTRUCTION DWG SHEET NO: A.202 FAIOxl5 SeatlelPlastianan - I Ox I 5 layoucdwg co 2 48" UNIT 2 -.16" KIOSK KEY PLAN SCALE: 1 /2 " =1 ' -0" 29" / 12" 7 „ LEFT ELEVATION SCALE: 1"=1'-0" — 29" UNIT 2 I UNIT 3 60 1/2" oo M MINI PYLON DISPLAY CABINET BASE to T 05" TRASH RECEPTACLE �. (0 N c0 It) GLASS DISPLAY CASE IS "FRAMELESS SILICONED APPLICATION." (TYP) M N F' () M A 18" UNIT 2 N PLAN VIEW H18" 27" / / / / i / / / / , / 48" N 9" GENERAL NOTES: 1. MIRRORS ARE SILICONED INTO OPENINGS. 2. UNITS 1, 2 & 3 HAVE LOCKING SLIDING DOORS, 3. ALL UNITS OVER 48" TALL WILL BE ANCHORED DOWN TO EXISTING SLAB WITH i" ANCHOR BOLTS IN ALL CORNERS OF BASE. 4. PLATFORM IS 2" RAISED FLOORING, WITH 2" ANCHOR BOLTS IN ALL FOUR CORNERS. 5. ALL WOOD MATERIAL IS i" FORMALDEHYDE FREE, FIRE RETARDANT MEDIUM DENSITY FIBERBOARD (MDF) PANELS (CLASS 1 A, COMBUSTIBLE MATERIAL) FLAME SPREAD 20, SMOKE DEVELOPED 100 ELECTRICAL NOTES: 1. ALL RECEPTACLE OUTLETS TO BE GROUNDED & GFI PROTECTED 2. LIGHTING INSIDE DISPLAY CASES & PYLON TO BE LUXEMBRIGHT LED SYSTEM. 30 ,21" SCALE: 1"=1'-0" .. 30" , , 21" OJI ==1 2 FRONT ELEVATION SCALE: 1"=1'-0" t N LUXEMBRIGHT LED SYSTEM MOUNTED INSIDE CABINET. „ MINI PYLON W/ 3D LOGO DISPLAY BASE CABINET - = f BASE MINI PYLON DISPLAY CABINET BASE 12” to I) 2 29" QUANTITY: 2 RIGHT ELEVATION SCALE: 1"=1 '-0" M FRONT ISOMETRIC SCALE: NTS LUXEMBRIGHT LED SYSTEM MOUNTED INSIDE CABINET. 21" MINI PYLON W/ 3D LOGO BASE cc M O —\ — SLIDING GLA OPEN 27" BACK ELEVATION SCALE: 1"=1'-0" BACK ISOMETRIC S DOORS.. ,\ 18" �I SCALE: NTS GLASS DISPLAY CASE IS "FRAMELESS SILICONED APPLICATION." (TYP) c0 M C.R. LAWRENCE CHROME SLIDING DOOR TRACKS. (TYP TOP & BOTTOM) C.R. LAWRENCE PUSH LOCKS. (TYP) OVERLAY DOORS, WITH PUSH LATCH & EURO HINGES. D09- (21 REVIEWED FOR CODE COMPLIANCE APPROVED J.L. 2 1 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 16 2009 PERMIT CENTER RETAIL KIOSK SOUTHCENTER MALL 633 SOUTHCENTER SEATTLE, WA 98188 FINISH SCHEDULE 0 FORMICA 9012—N1 "EBONY NATURELE FINISH" 0 CHEMETAL #909 "SATIN SILVER ALUMINUM" @ FORMICA 932 -58 "ANTIQUE WHITE" 0 NONE ®BEL AIR i" x 3g" STAINED BLACK BAMBOO VERTICAL 0 FORMICA 932 -58 "ANTIQUE WHITE" ® g" SAFETY GLASS 0 MIRROR F. \10x15 Seede\Phsdaesn - 10x15 layoucdwg 00 z 48" UNIT 2 —16 ". K KIOSK KEY PLAN SCALE: 1 /2 " =1 ' -0" r ------27" LEFT ELEVATION SCALE: 1"=1'-0" L r) M PYLON BASE 29 " UNIT 2 UNIT 3 60 1/2" CO N 05" TRASH RECEPTACLE CO N t 10 32" 31" SCALE: 1"=1'-0" DISPLAY CABINET 60 7/16" SCALE: 1"=1 '-0 60" UNIT 3 PLAN VIEW PYLON & CASH WRAP TO BE BUILT AS ONE UNIT. FRONT ELEVATION GENERAL NOTES: 1. MIRRORS ARE SILICONED INTO OPENINGS. 2. UNITS 1, 2 & 3 HAVE LOCKING SLIDING DOORS. 3. ALL UNITS OVER 48" TALL WILL BE ANCHORED DOWN TO EXISTING SLAB WITH i" ANCHOR BOLTS IN ALL CORNERS OF BASE. 4. PLATFORM IS 2" RAISED FLOORING, WITH 2" ANCHOR BOLTS IN ALL FOUR CORNERS. 5. ALL WOOD MATERIAL IS 4" FORMALDEHYDE FREE, FIRE RETARDANT MEDIUM DENSITY FIBERBOARD (MDF) PANELS (CLASS 1 A, COMBUSTIBLE MATERIAL) FLAME SPREAD 20, SMOKE DEVELOPED 100 ELECTRICAL NOTES: 1. ALL RECEPTACLE OUTLETS TO BE GROUNDED & GFI PROTECTED 2. LIGHTING INSIDE DISPLAY CASES & PYLON TO BE LUXEMBRIGHT LED SYSTEM. 24" t ranter 3" rem- �r 5" (0 M ea- 5" 3D LOGO BASE PYLON BASE 1n 2" 27" I o a J, 28" 3" SCALE: 1"= 1 — 0" —2 RIGHT ELEVATION FRONT ISOMETRIC SCALE: NTS PYLON & CASH WRAP TO BE BUILT AS ONE UNIT. 3D LOGO BASE co 5" ,, 60 1/2" BACK ELEVATION SCALE: 1"=1'-0" i BACK ISOMETRIC SCALE: NTS OVERLAY DOORS, WITH PUSH LATC & EURO HINGES. REVIEWED FOR CODE COMPLIANCE APPnnvED L009 City of Tukwila BUILDING DIVISION , RECEIVED CITY OF TUJKWILA JUL 16 2009 PERMIT CENTER RETAIL KIOSK SOUTHCENTER MALL 633 SOUTHCENTER SEATTLE, WA 98188 INTERNAL DRAFT AND NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY LICENSED PROFESSIONAL ARCHITECT OR ENGINEER. N Contractor Identification & Seals) ARCHITECTURAL STAMP AND SIGNATURE APPLIES ONLY TO ARCHITECTURAL PORTION OF DRAWINGS; NOT MECHANICAL, ELECTRICAL, STRUCTURAL, CIVIL, FIRE PROTECTION, OR ENGINEERING DISCIPLINE. ARCHITECT IS RESPONSIBLE FOR ARCHITECTURAL WORKS ONLY. ENGINEERING DISCIPLINES ARE RESPONSIBLE FOR ALL ENGINEERING WORK. ISSUED NO. REVISIONS A A A A A A A A A A A PROJECT NO: SHEET TITLE: SHEET NO: A ma 203 DESCRIPTION DESCRIPTION SCALE: DATE DATE UNIT 3 CONSTRUCTION DWG FINISH SCHEDULE 0 FORMICA 9012 -N1 "EBONY NATURELE FINISH" 0 CHEMETAL #909 "SATIN SILVER ALUMINUM" 0 FORMICA "ANTIQUE 932 -58 WHITE" 0 NONE OE BEL AIR STAINED R" x 3$" BLACK BAMBOO VERTICAL 0 FORMICA "ANTIQUE 932 -58 WHITE" ® g" SAFETY GLASS 0" MIRROR F. \10x15 S aUe\Ph,tlamn - IO cIO Pylondwg H- op z 48" UNIT 2 r16 "- KIOSK KEY PLAN SCALE: 1 /2 " =1' -0' SCALE: 1 /2 " =1 ' -0" in aD 0 1 27 „ 3 27 " LEFT ELEVATION SCALE: 1"=1 '-0" 29" UNIT 2 UNIT 3 60 1/2" 0 F) LIGHTING INSIDE PYLON TO BE LUXEMBRIGHT LED SYSTEM. (CONTINUOUS BOTH SIDES & BOTTOM) BACKLIT PYLON PYLON BASE i" MDF MATERIAL -\ 4" MDF MATERIAL DIMENSIONAL LOGO, OVER VINYL GRAPHIC, OVER 4" SUBSTRATE r II//Ilm/i/l,'s o PYLON PLAN VIEW SCALE: 3 " =1' -0” 5" N r - 4 MDF MATERIAL � 4" MDF MATERIAL c9 FRONT ELEVATION SCALE: 1"=1'-0" GENERAL NOTES: 1. MIRRORS ARE SILICONED INTO OPENINGS. 2. UNITS 1, 2 & 3 HAVE LOCKING SLIDING DOORS. 3. ALL UNITS OVER 48" TALL WILL BE ANCHORED DOWN TO EXISTING SLAB WITH 1" ANCHOR BOLTS IN ALL CORNERS OF BASE. 4. PLATFORM IS 2" RAISED FLOORING, WITH " ANCHOR BOLTS IN ALL FOUR CORNERS. 5. ALL WOOD MATERIAL IS 4" FORMALDEHYDE FREE, FIRE RETARDANT MEDIUM DENSITY FIBERBOARD (MDF) PANELS (CLASS 1 A, COMBUSTIBLE MATERIAL) FLAME SPREAD 20, SMOKE DEVELOPED 100 ELECTRICAL NOTES: 1. ALL RECEPTACLE OUTLETS TO BE GROUNDED & GFI PROTECTED 2. LIGHTING INSIDE DISPLAY CASES & PYLON TO BE LUXEMBRIGHT LED SYSTEM. - 8" TEMPERED GLASS, OVER VINYL GRAPHIC, OVER $" SIGN WHITE LEXAN. (VINYL GRAPHIC IS SANDWICHED BETWEEN) BACKLIT SIDE DASHED LINE REPRESENTS REMOVEABLE TOP PANEL. TO BE ATTACHED WITH SCREW FASTENERS. (ALLOWS REMOVAL OF GRAPHIC & SUBSTRATE, TO SLIDE OUT FROM TOP) LIGHTING INSIDE PYLON TO BE LUXEMBRIGHT LED SYSTEM. (CONTINUOUS BOTH SIDES & BOTTOM) BACKLIT PYLON $" TEMPERED GLASS, OVER 'A" SIGN WHITE LEXAN, W/ VINYL GRAPHIC. PYLON BASE RIGHT ELEVATION SCALE: 1"=1 '-0" 2 FRONT ISOMETRIC C� SCALE: NTS 5 "- BACK ELEVATION LIGHTING INSIDE PYLON TO BE LUXEMBRIGHT LED SYSTEM. (CONTINUOUS BOTH SIDES & BOTTOM) SCALE: 1 " =1' -0" BACK ISOMETRIC SCALE: NTS REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 1 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 16 2009 PERMIT CENTER RETAIL KIOSK SOUTHCENTER MALL 633 SOUTHCENTER SEATTLE, WA 98188 (Contractor Identification & Seals) INTERNAL DRAFT AND NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED BY LICENSED PROFESSIONAL ARCHITECT OR ENGINEER. ARCHITECTURAL STAMP AND SIGNATURE APPLIES ONLY TO ARCHITECTURAL PORTION OF DRAWINGS; NOT MECHANICAL, ELECTRICAL, STRUCTURAL, CIVIL, FIRE PROTECTION, OR ENGINEERING DISCIPLINE. ARCHITECT IS RESPONSIBLE FOR ARCHITECTURAL WORKS ONLY. ENGINEERING DISCIPLINES ARE RESPONSIBLE FOR ALL ENGINEERING WORK. ISSUED NO. REVISIONS N A A A A A A A A A A A PROJECT NO: SHEET TITLE: MAIN PYLON CONSTRUCTION DRAWING SHEET NO: A-204 DESCRIPTION DESCRIPTION SCALE: DATE DATE