Permit D09-131 - MICROSOFT - DOORS
MICROSOFT 3355S120PL EXPI 'ED 01 -31 -10 D09 -131 Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Tenant: Name: MICROSOFT Address: 3355 S 120 PL , TUKWILA WA Contractor: Name: KRAUSE /SCHEELAR, INC. Address: PO BOX 2018 , REDMOND WA 98052 Phone: 425 883 -1243 Contractor License No: KRAUSI *249P9 doc: IBC -10/06 Citylef Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.cr.tukwila.wa.us DEVELOPMENT PERMIT Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA 98168 Phone: Contact Person: Name: BOB WINFREY - CALLISON Address: 2240 5TH AVE SUITE 2400 , SEATTLE WA 98101 Phone: 206 -786 -5590 DESCRIPTION OF WORK: MODIFICATION OF 2 EXISTING DOORS, DOOR HARDWARE AND DOOR OPERATION Value of Construction: $10,000.00 Fees Collected: $442.74 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: II -B Occupancy per IBC: 0008 * *continued on next page ** Permit Number: D09 -131 Issue Date: 08/04/2009 Permit Expires On: 01/31/2010 Expiration Date: 10/03/2010 D09 -131 Printed: 08 -04 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D09 - 131 Issue Date: 08/04/2009 Permit Expires On: 01/31/2010 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N Signature: Print Name: doc: IBC -10/06 Private: Public: Profit: N Non - Profit: N Private: Public: Permit Center Authorized Signature: I hereby certify that I hav read and governing this k will e complied Date: 01I O 1 ed thi permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of pe t do not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or f work. I am authorized to sign and obtain this development ,perrpit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -131 Printed: 08 -04 -2009 Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Tenant: MICROSOFT 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D09 -131 Status: ISSUED Applied Date: 07/14/2009 Issue Date: 08/04/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** D09 -131 Printed: 08 -04 -2009 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http. / /www.ci.tukwila.wa.us Signature: h Print Nam - Date: The granting of this pe 't does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction o e pe orm ce of work. D09 -131 Printed: 08 -04 -2009 Site Address: 3355 S. 120TH PL., TUKWILA 98168 MICROSOFT Tenant Name: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hip: //www. ci. tukwila. wa. us Property Owners Name: SABEY CORPORATION Mailing Address: 12201 TUKWILA INTERNATIONAL BLVD Name: BOB WINFREY Mailing Address: CALLISON, 2240 5TH AVE, SUITE 2400 E -Mail Address: BOB.WINFREY @CALLISON.COM Contact Person: E -Mail Address: Contractor Registration Number: Company Name: CALLISON Mailing Address: 1420 5TH AVE, SUITE 2400 Contact Person: BOB WINFREY E -Mail Address: BOB.WINFREY @CALLISON.COM Contact Person: E -Mail Address: H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application doc Revised: 1.2009 bh SEATTLE City SEATTLE Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. t Project No. » (For ofice . use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 102- 304 - 9082 -09 Suite Number: New Tenant: WA State CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: (206) 786 -5590 SEATTLE WA City State Fax Number: (206) 623 -4625 Floor: ❑ Yes State City State Day Telephone: (206) 786 -5590 Fax Number: (206) 623 -4625 State 3 ..No 98168 Zip 98101 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: N/A Mailing Address: City Day Telephone: Fax Number: Expiration Date: Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record WA 98101 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: N/A Mailing Address: City Zip Day Telephone: Fax Number: Page 1 of 6 BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 10,000 Existing Building Valuation: $ OAK Scope of Work (please provide detailed information): MODIFICATION OF 2 EXISTING DOORS, DOOR HARDWARE AND DOOR OPERATION PER ATTACHED DOCUMENTATION AND SOO. Will there be new rack storage? ❑ Yes Provide All Building'Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ', explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets.. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design ap}roved by King County Health Department. H \Applications \Forms- Applications On Line\2009 Applications \I.2009 - Permit Application doe Revised: 1 -2009 bh El.. No If yes, a separate permit and plan submittal will be required. Page 2 of 6 Existing Interior Remodel Addition to Existing • Structure New Type of Construction per .. IBC Type of . Occupancy per IBC . I' Floor 188,222 0 2B B H3 2 " Floor 183,292 0 2B B 3` Floor 183,292 0 2B B Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport • Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 10,000 Existing Building Valuation: $ OAK Scope of Work (please provide detailed information): MODIFICATION OF 2 EXISTING DOORS, DOOR HARDWARE AND DOOR OPERATION PER ATTACHED DOCUMENTATION AND SOO. Will there be new rack storage? ❑ Yes Provide All Building'Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ', explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets.. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design ap}roved by King County Health Department. H \Applications \Forms- Applications On Line\2009 Applications \I.2009 - Permit Application doe Revised: 1 -2009 bh El.. No If yes, a separate permit and plan submittal will be required. Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Date Application Accepted: Date: 07/09/2009 Signature: Print Name: ,OB WINFREY Day Telephone: (206) 786 -5590 Mailing Address: 1420 5TH AVE, SUITE 2400 SEATTLE WA 98101 H \Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1.2009 bh City State Zip Date Application Expires: U Staff Initials: 1 Page 6 of 6 Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Applicant: MICROSOFT Receipt No.: R09 -01092 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Initials: WER Payment Date: 07/14/2009 01:54 PM User ID: 1655 Balance: $0.00 Payee: SECURITAS SECURITY SERVICES TRANSACTION LIST: Type Method Descriptio Amount doc: Receipt - 06 Payment Check 3428177 442.74 Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE RECEIPT Account Code Current Pmts 000/322.100 000/345.830 640.237.114 Total: $442.74 Permit Number: D09 -131 Status: PENDING Applied Date: 07/14/2009 Issue Date: Payment Amount: $442.74 265.60 172.64 4.50 E RECEIVE Printed: 07 -14 -2009 April 13, 2009 Dear Mr. Benedicto, T 208 623 4646 F 206 623 4625 www.callison.com FILE COP Permit No. City of Tukwila, Department of Community Development Bob Benedicto 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 -2544 Re: Code Modification Request Review Microsoft Data Center (Sabey Data Center) 3355 S. 120 Pl, Tukwila, WA98168 Permit Number D08 -276 "Access - controlled egress doors ", Section 1008.1.3.4, 2006 IBC & IF We respectfully request consideration for the use of a card -in card -out entry /egress control system which amends one of six stipulated conditions indicated as being necessary to meet the intent of Section 1008.1.3.4, "Access- controlled egress doors ", of the International Fire and Building Codes. It is the desire of Microsoft to substitute the use of a "proximity card reader" for the code described "sensor "(condition 1) in the highest value areas of the Data Center recently constructed. The procedures proposed make available the assurance of recorded entry and egress not available with the "sensor" defined within the Code. All other provisions of Section 1008.1.3.4 are to be met or exceeded by the planned installation. The operational scenario of these select areas will be as follows: 1. Entry to the area requires activating the door lock release by presenting a security issued card to a wall mounted proximity card reader. The action is logged automatically, and is a requirement for access to the area. 2. In a non -event egress the process is reversed via an identical proximity card reader mounted adjacent to the door on the egress side. 3. In an emergency or panic egress the door will allow free egress by any one of the following methods or events: a. Free egress can be initiated by an individual lifting a protective cover and activating a push button. This push button is in close proximity to the door and is clearly marked "PUSH TO EXIT". A local alarm will sound with the lifting of the cover and an alarm will be sent to security when and if the push button is pressed. This action unlocks the adjacent door's electrified mortised lockset allowing free passage. b. Loss of power to the system will automatically unlock the lockset. c. Activation of the building's automatic sprinkler system will unlock all doors equipped as "card -in card -out" egress. d. Activation of the buildings VESDA System will unlock the subject doors. e. Activation of the buildings fire alarm system will unlock the subject doors. X09- 131 1420 FIFTH AVENUE #2400 SEATTLE. WASHINGTON 98101 =2343 CALLISON REVIEWED Fp CODE COMPLIANCE APPRfw JUL 2 3 1uud City of Tukwila BUILDING RECEIVED JUL 14 PERMIT CENTER Al 3355 S. 120th Pl, Tukwila, WA98168, Permit Number D08 -276 April 13, 2009 Page 2 f. The card -in card -out exit doors can be unlocked remotely from the Security Center in the building. These areas are also under camera surveillance from the on premises Security Office. The exits in question are also adjacent to telephones, many of which automatically dial the manned security office. g. The provision of the code that requires this type of exit not be secured when the public is present does not apply, as the data center is a limited access facility. In our professional opinion, the proposed code modification meets the intent of the Code and insures a level of safety equivalent to, or better than, that required by the Code. The condition requested for approval meets the intent of Section 1008.1.3.4 and provides Microsoft with the heightened level of security required by the sensitivity of the operation without compromising safety. • The Tukwila facility is a part of a unified global array of similar facilities; matching operating and security systems is a part of Microsoft's overall effort to insure safety. The card -in card -out egress procedure is in place and operating elsewhere in jurisdictions covered by the IFC & IBC. • The safe guard of no "special knowledge" is counterbalanced by the fact that the "knowledge" of the systems has become second nature to the operation based on ingrained familiarity. The population exposed to this exiting procedure is encoded with the common knowledge based on training and repetition. • The redundancies of alarm and security overrides provide a safe and easily initiated free egress from any of the subject areas. The six requirements in Section 1008.1.3.4; sensor, loss of power, fire alarm, sprinkler system, manual unlocking device, and concern for public access are amplified by the presence of security direct telephones, camera surveillance, and the awareness created by the recorded entry process. Thank you for your consideration of this proposal. Sincerely, //dee/s4/i Wm. Stewart Fetterley,'A Project Manager c: Microsoft: Ryan Roberts, Sean James Olympic Assoc.: Bill Clark Callison: J:\Projects\Microsoft_Data\Mstk5 \Correspondence \09 -Code Agencies \CMR Letter.Doc • July 9, 2009 City of Tukwila Department of Community Development 6300 Southcenter Blvd Suite 100 Tukwila, WA 98188 Re: Microsoft Data Center TK5 Security Lock Changes To Whom It May Concern: The following scope is to provide the design intent to comply with local AHJ and IBC 1008.1.3.4 Access - controlled egress doors. PERMITS REQUIRED Building permit Electrical permit (low voltage) Fire systems /Alarm panel work and configuration/programming Estimated cost - $10,000.00 Scope specific to rooms /doors: AIM ROOM — Room 352 1. Lock spec — See attached data sheets for complete information. Mfg is SDC EMLock 1500 Series. Options to include DPS (either factory installed or field installed) and Top Jamb Mounting option. The door height will not be restricted any more than it is currently with the door closer arm installed (door height is 10' -0 "). a. Mag lock — 1511 with DPS and Top frame mount (see attached sheet). b. AIM door lockset — Modify to passage function. Best Lock 45H7RN15STD (see attached sheet) bO'H3 1 420 FIFTH AVENUE 02400 SEATTLE, WASHINGTON 98101 -2343 T 206 623 4646 F 206 623 4625 www.callison.com CALLISON REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 3 2009 City of Tukwila BUILDING DIViRiniv RECEIVED JUL 14 2009 PERMIT CENTER City of Tukwila Microsoft Data Center, TK5 July 9, 2009 Page 2 2. Electrical a. Card reader and mag locks to be configured to building security system and fire panel (as required) b. Telephone (re-land or pull) to meet requirements of AHJ c. Mag locks to be installed and wired as required — Egress side, Active leaf (LEFT) 3. FIRE SYSTEMBUILDING SYSTEM CONNECTIVITY a. Configure lock systems to building fire alarm panels as required b. Configure lock systems to building security systems as required 4. SIGNAGE a. Push to Exit (MS Standard signage) See attached sample COLO DOOR — Room 353 2. Lock spec — See attached data sheets for complete information. Mfg is SDC EMLock 1500 Series. Options to include DPS (either factory installed or field installed) and Top Jamb Mounting option. The door height will not be restricted any more than it is currently with the door closer arm installed (door height is 10' -0 "). a. Mag lock — 1512 (Double door) with DPS and Top frame mount (see attached sheet). b. Colo door lockset — Modify existing panic hardware to perform as passage function. 3. Electrical a. Relocate card reader from left to right side. b. Relocate Push to Exit from left to right side. c. Provide for telephone with ring down to building security. Right side position. d. Mag locks to be configured to existing security devices and functions. e. The above elements are to be within 5 feet of the doors. Mounting heights between 3' -4" and 4' -0" AFF. 4. FIRE SYSTEM/BUILDING SYSTEMS CONNECTIVITY a. Configure all new locks and devices to building systems as required b. Configure all new locks and devices to building fire panels as require. 5. SIGNAGE a. Push to Exit (MS standard signage) See attached sample City of Tukwila Microsoft Data Center, TK5 July 9, 2009 Page 3 TESTING OF ABOVE Using the attached testing scenario verify that all installed systems meet the requirements of the AHJ. Contractor to call for and participate in review and acceptance by AHJ and others as required. GENERATOR SW DOOR Panic bar lever set installed. Remove exterior keyway, lever and escutcheon. Install cover plate. Ensure any alarm/monitoring points /systems currently installed work as designed after modifications. MISC Patch, repair and paint all areas directly affected by the installation and modification of the above listed systems. Return any surplus parts to Microsoft. Additional signage is required at three emergency exit doors. See attached Microsoft approved design for verbiage and details. Sincerely, Bob Winfrey Project Manager Enclosure c:Callison: TK5 file 208089.00 Itr- name- authordated created/Original sent via: Mail Courier Express Service Fax Hand Delivered Other, Copies seat via Mail Fax Courier Express Service Other Various CONNECT EXISTING SECURITY DEVICES TO NEW MAG LOCKS TK 5 DATA CENTER EXPANSION - CALLISON PROJ. # 208089.00 SECURITY HARDWARE MODIFICATIONS 28-APR-09 . 4 • ir 4'76. '10 • “•-' ADJUST (MODIFY) EXISTING LATCH (PANIC BARS) TO PASSAGE LATCHING ONLY TK 5 DATA CENTER EXPANSION - CALLISON PROJ. # 208089.00 SECURITY HARDWARE MODIFICATIONS 28- APR -09 ADD MAG LOCK AND CONNECT TO REQUIRED BUILDING AND SECURITY SYSTEMS (Confirm clearance with DC Operator) RELOCATED EXISTING SECURITY CARD READER Connect to Mag Lock and Building Systems EXISTING CARD READER AND PUSH TO EXIT. (TO BE RELOCATED) ADJUST (MODIFY) EXISTING PANIC BARS TO PASSAGE LATCHING ONLY New Location Security and egress information "PUSH TO EXIT" Button, lift cover and signage. Confirm sign text size and location with AHJ. Connect to Mag Lock and Budding Systems ADDED TELEPHONE: Locate telephone and confirm compliance with AHJ. DOOR 353 COLO RM. EGRESS ADD MAG LOCK AND CONNECT TO REQUIRED BUILDING AND SECURITY SYSTEMS (Confirm clearance with DC Operator) TK 5 DATA CENTER EXPANSION - CALLISON PROJ. # 208089.00 SECURITY HARDWARE MODIFICATIONS 28- APR -09 Final Configuration 09- 05-03 MODIFY EXISTING MORTISE LOCK TO PERFORM AS A PASSAGE LATCH FUNCTION CONNECT EXISTING SECURITY DEVICES TO NEW MAG LOCKS DOOR 352 AIM RM. EGRESS Security and egress information TELEPHONE: Locate existing telephone and confirm compliance with AHJ. "PUSH TO EXIT" Button, lift cover and signage. Confirm sign text size and location with AHJ. Connect to Mag Lock and Building Systems EXISTING SECURITY CARD READER Connect to Mag Lock and Building Systems ADD MAG LOCK AND CONNECT TO REQUIRED BUILDING AND SECURITY SYSTEMS (Confirm clearance with DC Operator) J Existing inactive leaf; no modification to hardware or function. Door cannot be operated with out the active leaf open. Active leaf cannot be closed without inactive in closed position. MODIFY EXISTING MORTISE LOCK TO PERFORM AS A PASSAGE LATCH FUNCTION TK 5 DATA CENTER EXPANSION - CALLISON PROJ. # 208089.00 SECURITY HARDWARE MODIFICATIONS 28- APR -09 TK5 DATA CENTER EXPANSION - CALLISON PROJ. # 208089.00 SECURITY HARDWARE MODIFICATIONS 28- APR -09 REMOVE KEYWAY, LEVER AND ESCUTCHEON. REPLACE WITH COVER PLATE. GENERATOR ROOM EXTERIOR DOOR SW CORNER TK5 DATA CENTER EXPANSION - CALLISON PROJ. # 208089.00 SECURITY HARDWARE MODIFICATIONS 28- APR -09 GENERATOR ROOM INTERIOR SW EGRESS DOOR 40HTK Series 0S2 Function I Code 14 Lever /Knob Style H Trim Style 626 Finishes • RH Door Hand Options 40HTK- IS1- inside lever only Standard Levers: H- 2 3 /4' dia. 605 606 D- double cylinder trim kit IS2- inside lever x thumb turn ,,ii 3- solid tube /return R- 2 3 /4 - dia. 611 612 Thick Door- (specify RHRB 153- inside lever x cylinder � 12- solid tube no return C7. S- 3 '/ z " dia. 613 618 thickness if other than IS4'- inside cylinder only 14- curved return & J- wrought 819 625 1 3 /4 " ) J- wrought IS5- inside thumb turn only 15- contour /angle M- forged 626 629 SH- security head screws R- classroom 15- contour/angle return ` - '' - IS6- inside lever x cylinder x visual indicator return 6. 16- curve /no return c7 N- forged (concealed cylinder) 630 690 TL- tactile lever/knob 051- outside lever only 0S2- outside lever x cylinder 053- outside lever x access plate 0S4'- outside cylinder only 17RH- right handed gull wing 17L gull l wing left handed 6 613 619 TAC- tactile lever/knob 7/8 LTC- 7/8" lip- to-center 0S5- outside lever x visual indicator Knobs: MV'- Vandal trim Bright strike 056- inside lever x cylinder x visual indicator 4- round order levers: See in (forged escutcheon; 605 611 page 10-13 page 3 page 3 page 3 14, 15, 16 lever style � only) 45H Series 7 Core Housing R 14 Function I Lever /Knob Code j i Style H Trim Style 626 Finishes • RH Door Hand Options • t. • -- - pin A- office Standard Levers: 9 H- 2 3 /4' dia. 618 626 RH LL- lead lined standard housin . D- storeroom 3- solid tube /return R - 2 3 /4" dia. 630 690 RHRB SH- security head screws mortise lock accep - . L L- privacy 12- solid tube/no return 47. S- 3 dia. LH Thick Door- (specify 626 629 all Best N- passage I 14- curved return ( J- wrought Satin LHRB thickness if other than cores R- classroom 15- contour/angle return ` - '' - M- forged 606 612 13/4") T- dormitory ' ' ' ''' ' , b etc. 17- gull wing C7- N- forged (concealed cylinder) 613 619 TAC- tactile lever/knob 7/8 LTC- 7/8" lip- to-center Decorative & special MV'- Vandal trim Bright strike order levers: See in (forged escutcheon; 605 611 VIN'- visual indicator special section this catalog Knobs: 14, 15, 16 lever style � only) 625 629 ROE- request -to -exit 4- round page 10-13 page 3 page 3 page 3 page 3 47H Series 47H- lever/ knob high security mortise lock 7 Core Housing 7- 7 pin housing, must use 5C cores and long blade keys R Function I Code A- office D- storeroom R- classroom T- dormitory etc. Page 3 14 I Lever /Knob Style Standard Levers: ,ii 3 -solid tube/return l7- 12- solid return no return 14- curved return& 15- contour /angle return & ,i 16- curve/no return �7. 17 -gull wing Knobs: 4- round page 3 M Trim Style M- forged MV'- vandal trim (forged escutcheon; 14, 15, 16 lever styles only)' page 3 626 Finishes 1 626 630 page 3 RH Door Hand RH RHRB LH LHRB page 3 K- LL- Thick thickness 1 TAC- ROE- Options non UL cylinder lead lined Door- (specify if other than ") tactile lever/knob request -to -exit 45HCA Series R Function ;Code 626 Finishes RH Door Hand Options 45HCA - A- office 605 606 RH SH- security head screws case only mortise lock D- storeroom 611 612 RHRB R- classroom 613 618 LH T- dormitory 619 625 LHRB etc. 626 629 630 690 page 10-13 page 3 page 3 W CI 0 0 0 I 6 HOW TO ORDER: 45H THIS SET These options and styles may not be immediately available. HOW TO ORDER: 47H These options may not be immediate y available. HOW TO ORDER: 45H CASE ONLY HOW TO ORDER: 40H TRIM KITS ' Only works with H, R, S, M and N trim. r3E El EA\/Y ®uTv NA EMLoth® 1500 Series SDC's patented EMLock® design represents the pinnacle of magnetic lock evolution. The modular EMLock® assembly makes them easy to stock, install, upgrade and maintain. • Modular Design • Modular Upgrade Kits • Field Upgradeable without removing from the frame • Uniform Design & Installation • Identical Housing, Template & Accessories • Quick Mount Assembly SDC 1500 series EMLocks® include a lifetime warranty and are available in 650Ibs, 1200Ibs, and 1650Ibs holding force. Compatible with any access control system, all EmLocks° are adaptable to virtually any application utilizing Top Jamb or Glass Door mounting kits. The epoxy -less design provides a superior appearance with a plated or anodized finish on all sides. The interlocking EZ mount assembly leaves hands free for wiring and securing of mounting screws. EMLocks® are UL Listed and ANSI Grade 1 compliant. EMLock® EZ Upgrade Kits Field upgradeable by distributors, installers and maintenance staff. No need to ever remove a lock from the frame to upgrade or exchange internal components. Upgrade Modules Include: • Relock Delay Timer • Magnetic Bond Sensor • Door Status Sensors • Anti- Tamper Switch • Holding Force Upgrade • Energy Saver Upgrade MEA c ®us BMA" siQ tE Listed usne Online System Wizard and Project Manager at IDPS Option W;(ul : . - i ! I t New Modular Kits For complete details contact SDC to request the Modular Upgrade Kit datasheet or download from the SDC website: www .sdcsecuritycom /docLibraryasox EZ -T -10 Timer Input Module EZ -B-10 Magnetic Bond Sensor EZ -A Anti- Tamper Switch EZ-D-10 Door Position Sensor 3580 Willow Lane, Westlake Village CA 91361 (800) 413 -8783 (805) 494 -0622 Fax: (805) 494 -8861 Email: service @SDCsecurity.com 1510 Series Grade 1 16501b / 748 Kg Holding Force SINGLE AND DOUBLE 1511 Single EMLock 1512 Double EMLock 1513 Single, split armature for pair of doors Specifications Voltage: 12/24VDC Voltage Sensing Input Single: 350mA © 24VDC; 670mA @ 12VDC 11 "Lx 2.75 "Hx1.562 "D (279.4 x 69.9 x 39.7 mm) Double: 700mA @ 24VDC; 1.34A @12VDC 22" L x 2.75" H x 1.562" D (558.8 x 69.9 x 39.7 mm) Finishes ✓ 628 Aluminum (standard) X Dark bronze powder coat (313/613 equal) Y 335 Black anodized 1570 Series Grade 1 1200 lb / 544 Kg Holding Force 3 Watts Energy Saver UL Listed U.S. & Canada: GWXT Auxiliary Locks CVXJ Burglary Resistant Electrically Operated Door Lock UL10C: Position Positive Pressure Compliant UBC: Classified in accordance with Uniform Building Code standard 7 -2 "Fire Test for Door Assemblies - --�_• .w+,#, 1571 Ni -' "•_ 1573 1571 Single EMLock 1572 Double EMLock 1573 Single, split armature for pair of doors Specifications Voltage:12/24VDC Voltage Sensing Input Single: 125mA @ 24VDC; 250mA @ 12VDC 11"L x 2.75 "H x 1.562 "D (279.4 x 69.9 x 39.7 mm) Double: 250mA © 24VDC; 500mA @ 12VDC 22" L x 2.75" H x 1.562" D (558.8 x 69.9 x 39.7 mm) Listings 8 Performance Specifications J Plated Finishes (special order) C 605 Bright brass P 625 Bright chrome D 606 Dull brass Q 626 Dull chrome 1580 Series Grade 1 650 lb / 29511 kg Holding Force sy xys 1581 4� 1582 1581 Single EMLock 1582 Double EMLock Specifications Voltage: 12/24VDC Voltage Sensing Input Single: 220mA @ 24VDC; 440mA @ 12VDC 8.75 "L x 2.125 "H x 1.25 "D (222.2 x 54 x 31.8 mm) Double: 440mA @ 24VDC; 880mA @ 12VDC 17.5" Lx 2.125" H x 1.25" D (444.5 x 54 x 31.8 mm) ANSIBHMA A156.23: BHMA Certified CSFM: California State Fire Marshal Listed 3774-0324:100 MEA: City of New York 61 -95-E Grade 1, one million cycles T Adjustable Timer: Built -in field adj. 0 -30 sec. re -lock delay. Specify one for single or double EMLocks (not available with 1580 series) D Door Position Sensor: Indicates door open and door closed. Specify two for double EMLocks® (not available with 1513 and 1573) SPDT Dry, 250 mA @ 30VDC. B Magnetic Bond Sensor: Indicates locked and unlocked, low holding power, tampering and obstruction between armature and magnetic core. Specify (2) for double EMLocks (Not available with 1513 and 1573) • 1510 & 1570 Series: SPDT Dry, 250 mA @ 30VDC. • 1580 Series: SPST N.O., Dry, 250 mA @ 30VDC. L Bicolor Status LED Indicator. Field selectable Red, Green, or Amber (requires additional wiring) Indicates lock energized when wired to lock input. Indicates de- energized/unlocked or "Enter /Go" when wired to optional timer module. Indicates energized and de- energized or "Enter /Go" when wired to access control auxiliary output. Indicates door is closed and locked and door is unlocked when wired to BA. A Anti - tamper Sensor. Indicates access cover removal. SPDT Dry, 1 Amp @ 30VDC. Field Installed Option kits Ordered separately for field upgrade For complete details contact SDC to request the Modular Upgrade Kit datasheet or download from the SDC website: www .sdcsecurity.comfdocLibrary.aspx All available through shipQuidk Inventory EZ -T -10 Adjustable Timer Input Module: Specify (1) for single or double Em Locks (not available with 1580 series) EZ -D -10 1510,1570 Door Position Sensor Module: Specify (2) for double EMLocks® (not available with 1513 and 1573) EZ -D-80 1580 Door Position Sensor Module: Specify (2) for double EMLocks EZ -B -10 1510, 1570 Magnetic Bond Sensor Module: Specify (2) for double EMLocks (Not available with 1513,1573) EZ -B-80 1580 Magnetic Bond Sensor Module: Specify (2) for double EMLocks Top Jamb Mounting Brackets See page 2 for available finish Kits for 1511, 1512, 1571, 1572 Locks TJ1 Single TJ2 Double Kits for 1581, 1582 Locks TJ81 Single TJ82 Double Adjustable brackets Architectural Housings See page 2 for available finish Single Door Housing 30 30" Lock housing 36 36" Lock housing 40 40" Lock housing 48 48" Lock housing CH Custom length. Specify exact length EZ-A EZ -1510W EZ -1570W Double Door Housing 60 60" Lock housing 72 72" Lock housing 84 84" Lock housing 96 96" Lock housing CH Custom length. Specify exact length Anti - Tamper Switch Module: Indicates cover plate removal. Holding Force Module: Exchange a 12001b wire coil (1570 series) with this 1650Ib wire cal. Specify (2) for double EMLocks Energy Saver Module: Save on power supply and long term energy costs by exchanging 8.4 Watt, 1650lb coil with 3 Watt, 1200lb holding force coil. Specify (2) for double EMLocks Universal Glass Door Mounting kit See page 2 for available finish Kit for 1511, 1571, 1581 HDB1 Single Kit for 1512, 1572, 1582 HDB2 Double, 2 single kits Adjustable brackets for glass thickness leo Specify housings with your EMLocks Example: 1511V-30; 1512V -60 Full Width Housings - appear as part of the frame to provide a superior architectural appearance. Compatible with Models: 1511, 1512, 1571, 1572 with or without HDB kits or TJ brackets. Vertical Housings - Side jamb mount, accommodates two 1571 or two 1511 EMLocks® providing 2400 or 3300 lbs of holding force. Vertical Housings V82 82" high opening CV Custom length. Specify exact length p • Field Upgrade without Removing from the Frame Field Install • Monitoring outputs • Timers • Top jamb "Z" kit • Glass door kits Interloddng Quids Mount Assembly Sett tapping & idling mounting sc/ews • Gloss door mounting kit • AB series angle brackets • Metal or aluminum frame • Gloss door w/o top rail • Push side mounting U111 1511 (26) • Full width architectural housing • Specify length 130', 36 40 481 • Aluminum (rane • Aluminum & glass door • Push side mounting Typical Door Applications t$ 11 1571 1381 • Hollow metal frame • Wood /hollow metal door • Push side mounting 1311 -111 1371.111 15814181 • Top jamb mounting kit • Hollow metal frame • Wood or hollow metal door • Pull side mounting 1519 1379 • Split armature • Hollow metal frame • Wood or hollow metal doors • Push side mounting 1514 1572 1582 • Hollow metal frame • Wood or hollow metal doors • Push side mounting Is I2 - HDS2 137241D82 1582 4Wss • HDB Gloss door mounting kit • AB series angle bracket • Metal or aluminum frame • Gloss door without top roil • Push side mounting • l Universal Header Bracket Used in lieu of angle brackets, the Universal Header Bracket provides a faster mounting solution, saving time and labor costs for several EMLock models. Reduce potential for mis -sized and misaligned mounting holes, broken taps, removal of broken taps. Combined with the interlocking E -Z mount assembly, save up to a full days labor with the installation of 20 locks. • Solid 1" bar provides higher security and superior aesthetics. • Machined wire chase provides concealed and secure wiring • Multiple pre - drilled and tapped mounting holes to accommodate the use of several different locks on either 4" or 4.5" aluminum frames See page 2 for available finish UB11 Bracket for 1511, 1513, 1571, 1573. Dimensions: 1" x 1" x 11" UB12 Bracket for 1512 and 1572. Dimensions 1' x 1' x 22" 6 • � m Machined I Moles Pre drilled 8 Countersunk Pre drilled and Tapped Wire Chase For Frame Mounting Lock Mounting Moles Spacer Bracket • Aluminum frames with blade stop - lowers EMLock below blade stop • Machined wire chase provides multiple points for concealed wire entry from concrete filled frames • Pre- drilled and tapped specifically for 1510, 1570, and 1580 EmLock • Aluminum Finish UF11V Bracket for 1511, 1513, 1571, 1573. Dimensions: 1/2" x 1 -1/2" x 11" UF12V Bracket for 1512 and 1572. Dimensions: 1/2" x 1 -1/2" x 22" UF81V Bracket for 1581. Dimensions: 1/2" x 1 -1/4" x 8 -3/4" UF82V Bracket for 1582. Dimensions: 1/2" x 1 -1/4" x 17 -1/2" UF11V 1 Armature Mounting Plate •� a • a • • UF81V Armature Mounting Plate Aluminum frame with 12' blade stop I — The Armature Mounting plate provides a solution for mounting the EMLock armature to the top rail of aluminum, glass, wood and hollow metal doors that do not permit the use of thru bolts. Available in black finish. AR11Y Armature mounting plate for 1511, 1571 Specify two for models 1512, 1572 ARI1YDArmature mounting plate with DPS for 1511, 1571 Hollow metal concrete filled frame 1 www.SDCsecurity.com E -mail: service @SDCsecurity.com Filler Plates For extension of the stop to provide a proper mounting surface on the underside of the header See Figure 1 B. FOR 8-3/4" (222mm) SINGLE EMLOCK MODELS 1581, 101V81S, 101A81S, 101V81T, 101A81T PART # A x B FP01 1/8" x 1 -1/4" (3 x 32mm) FP02 FP03 FPO4 FP05 FOR 11" (279mm) SINGLE EMLOCK MODELS 1511 1571 1511S 101A71S 101V71S 1513 1573 1511T 101A71T 101V71T PART # A x B FP11 1/8" x 1 -1/4" (3 x 32mm) FP12 1/4" x 1 -1/4" (6 x 32mm) FP13 3/8" x 1 -1/4" (10 x 32mm) FP14 1/2" x 1 -1/4" (13 x 32mm) FP15 5/8" x 1 -1/4" (16 x 32mm) FOR 17 -1/2" (445mm) DOUBLE EMLOCK® MODEL 1582 PART # A x B FP30 1/8" x 1 -1/4" (3 x 32mm) FP31 1/4" x 1 -1/4" (6 x 32mm) FP32 3/8" x 1 -1/4° (10 x 32mm) FP33 1/2" x 1 -1/4" (13 x 32mm) FP34 5/8" x 1 -1/4' (16 x 32mm) FOR 22' (559mm) DOUBLE EMLOCK MODELS 1512 / 1572 PART # A x B FP21 1/8" x 1 -1/4" (3 x 32mm) FP22 FP23 FP24 FP25 Figure 1A Regular ! 2" storm 25/16' 50mm 1/4" x 1 -1/4' (6 x 32mm) 3/8" x 1 -1/4" (10 x 32mm) 1/2" x 1 -1/4" (13 x 32mm) 5/8" x 1 -1/4" (16 x 32mm) 1/4" x 1 -1/4" (6 x 32mm) 3/8" x 1 -1/4" (10 x 32mm) 1/2" x 1 -1/4" (13 x 32mm) 5/8" x 1 -1/4" (16 x 32mm) 1580 Serbs 151011570 Soros SECURITY DOOR CONTROLS ® 2007 Security Door Controls Printed in the U.S.A. Figure 1B Filler Plato 2' 11580 Series Si mm Filler Plate 2 5116" 1 151011570 semi Sorbs Angle Brackets Used as extension on shallow door frames to provide adequate mounting surface. See Figure 1C. FOR 8 -3/4" (222mm) SINGLE EMLOCK MODEL 1581, 101V81S, 101A81S, 101V81T, 101A81T PART # A x B ABO1 1" x 1" (25 x 25mm) ABO2 1" x 1 -1/2" (25 x 38mm) ABO3 1 -1/2" x 1 -1/2" (38 x 38mm) ABO4 2" x 1 -1/2" (51 x 38mm) FOR 11" (279mm) SINGLE EMLOCK MODELS 1511 1571 1511S 101A71S 101V71S 1513 1573 1511T 101A71T 101V71T PART # AB11 AB12 AB13 AB14 A x B 1" x 1" (25 x 25mm) 1" x 1 -1/2" (25 x 38mm) 1 -1/2" x 1 -1/2" (38 x 38mm) 2" x 1 -1/2" (51 x 38mm) FOR 17 -1/2' (445mm) DOUBLE EMLOCK MODEL 1582 PART # A x B AB30 1" x 1" (25 x 25mm) AB31 1" x 1 -1/2" (25 x 38mm) AB32 1 -1/2" x 1 -1/2" (38 x 38mm) AB33 2" x 1 -1/2" (51 x 38mm) FOR 22" (559mm) DOUBLE EMLOCK MODELS 1512 / 1572 PART # A x B AB21 1" x 1" (25 x 25mm) AB22 1° x 1 -1/2" (25 x 38mm) AB23 1 -1/2" x 1 -1/2" (38 x 38mm) AB24 2' x 1 -1/2" (51 x 38mm) Figure IC Angle Bracket 2" SImm i Le --A— \ Angle Bracket 1560 Series 2 116" 151011570 59rnm Series P.O. Box 6219, Westlake Village, CA 91359 -6219 3580 Willow Lane, Westlake Village, CA 91361 -4219 (805) 494 -0624 • (800) 413 -8783 • Fax (805) 494 -8861 Email: ser4ce@SDCsecurity.com www.SDCsecurity.com mom LIT - EMLock Brochure 10/07 5000 BA EZ Option Kit Upgrades - Emlo 1511, 1513, 1571, 1573 EMLock EZ Kits Field Upgradeable Option Modules for 1511, 1513, 1571, 1573 SDC's patented EMLock design represents the pinnacle of magnetic lock evolution. The modular EMLock assembly makes them easy to stock, install, upgrade and maintain. Field Upgradeable by Distributors, Installers and Maintenance Staff No need to ever remove a lock from the frame to upgrade or exchange internal components. EZ -D -10: DOOR POSITION SENSOR Modular Kit n FIELD UPGRADE • Relock Delay Timer • Magnetic Bond Sensor • Door Status Sensors • Anti- Tamper Switch • Holding Force Upgrade • Energy Saver Upgrade EZ -B -10 MAGNETIC BOND SENSOR Modular Kit www.SDCsecurity.com Email: service@SDCsecurity.com FM �� "www.SDCsecuritycom E -mail: service@SDCsecuritycom Relock Delay Timer, Adjustable 1 to 30 Seconds. EZ -T -1O TIMER INPUT MODULE Modular Kit Application: The Timer Input Module delays relocking of access controlled doors to provide persons ample time needed for entry or egress. Momentary interruption of power to the lock input activates the timer module. Momentary, N.C. Dry Contact required. Contact actuation unlocks the door for 1 — 30 seconds. Disconnect magnetic cord wires and remove Input module Attach magnetic core wire connector to timer module Adjustable 1 - 30 Seconds 'Typical factory setting approximately 5 seconds Awn clockwise to Increase time SECURITY DOOR CONTROLS ® 2007 Security Door Controls Printed in the U.S.A. LIT - Datasheet date qty vendor ri Attach cover plate P.O. Box 6219, Westlake Village, CA 91359 -6219 3580 Willow Lane, Westlake Village, CA 91361 -4219 (805) 494 -0622 . (800) 413 -8783 • Fax (805) 494 -8861 Emall: service @SDCsecuritycom www.SDCsecurity.com n=mi..■. EZ Option Kit Upgrades - Emlock 1511, 1513, 1571, 1573 ' Not available for 1513, 1573 While a Door Status Sensor indicates the door is open or closed, SDC's Magnetic Bond Sensor provides higher security monitoring by indicating the locked / unlocked mode, tampering and low holding force. The use of both the door status and magnetic bond sensor is recommended for high security applications. Remove 1 screw from the case bottom. Place the Magnetic Bond Sensor at the base of the Magnetic Core. Secure sensor in place with screw as shown. Place Input module vertically between post at each side of case. Ea -B -10 MAGNETIC BOND SENSOR Modular Kit The Magnetic Bond Sensor should be positioned as shown below, after step 4. Application: Lock secure status annunciation, mantrap system logic, CCTV camera activation. Output: SPDT Dry Contact, 250 mA @ 12/24VDC Lift Input module and magnetic coil from the case. Place magnetic coil firmly between core lamination as shown. Connect magneticbond sensor wires to the Input module B Option connector as shown. 9 Attach cover plate. Y LSO 9001 : 2000 www.SDCsecurity.com Email: service@SDCsecurity.com FM 52705 'www.SDCsecurity.corn E -mail: service @SDCsecuritycorn • EI -D -10: DOOR POSITION SENSOR Modular Kit Indicates the door is open and dosed. Not available for 1513, 1573 Application: Door position status annunciation, anti - tailgating, interlock, mantrap and communicating bathroom system logic. Output: SPDT Dry Contact, 250 mA @ 12/24VDC I Remove armature from frame and attach door status module to armature Place anti- tamper switch as shown. Cover depresses switch arm when mounted SECURITY DOOR CONTROLS © 2007 Security Door Controls Printed in the U.S.A. LIT - Datasheet date qty vendor EI -A: ANTI-TAMPER SWITCH - Modular Kit Indicates cover plate removal Output: SPDT Dry Contact, 3 Amp @ 12/24VDC P.O. Box 6219, Westlake Village, CA 91359-6219 3580 Willow Lane, Westlake Village, CA 91361-4219 (805) 494 -0644 . (800) 413 -8783 . Fax (805) 494 -8861 Email: service@SDCsecurlty.com www.SDCsecurity.com EZ Option Kit Upgrades - Emloc 1511, 1513, 1571, 1573 EZ - 1510W Holding Force Upgrade EY - 1570W Energy Saver Upgrade All 1511, 1512, 1513, 1571, 1572 and 1573 magnetic coils are field interchangeable without removing the lock from the frame. There is no reason to remove and ship a lock for exchange. Benefits of this interchangeability include: Applications Distributors with limited stock may exchange coils to fulfill specific special sales needs, i.e. a 1570 with Dark Bronze finish may be upgraded to a 1511 with dark bronze finish and visa versa. Installers may field upgrade to an Energy Saver where power supply capacity is limited or upgrade to higher holding force where 1200 lbs holding force proves inadequate, i.e. psychiatric or rehab center applications. • EZ -1510W Holding Force Upgrade: Exchange 1200 lb coil with 1650 lb holding force coil • EZ -1570W Energy Saver Upgrade: Save on power supply and long term energy costs by exchanging 8.4 Watt,1650 lb coil with 3 Watt, 1200 lb holding force coil • Eliminate labor, shipping costs and time associated with special orders or complete lock removal and replacement. Place Input module vertically between post at each side of case. Lift Input module and magnetic coil from the case. Place magnetic coil firmly between core lamination as shown. Connect magnetiebond sensor wires to the Input module B Option connector as shown. SECURITY DOOR CONTROLS I I ! I www.SDCsecurity.com Email: service@SDCsecurity.com Fwszros I Sign is 2 -1/2" Height X 11" Wide PROJ NO: PROJ MGR: BUILDING: 0. 1-1/2" Microsoft DATA CENTER DATA CENTER INTERIOR SIGNAGE 1 6' OF DOOR EMERGENCY EXIT ONLY DO NOT OPEN ALARM WILL SOUND Copy to be tirst-eurtace vinyl to match 3M-7725-33 Red. fcxd: Segoe Semi-Sold. TYPE 'M - SECONDARY! EMERGENCY EXIT (DATA CENTER! NON SCALE: 3' 0 M - SECTION SCALE: 3 V 0' SIGN TYPE SECONDARY EXIT (NON-OFFICE) 1-08 M-2.D Action Entry Present card to reader Present card to reader don't open door Test door relock time Test door relock time on open Test door forced open Exit Test exit card reader Lift emergency exit cover Test emergency exit button Simulate fire alarm Use phone to call security Testing procedure for card in card out doors Expected Response Door should unlock Expect access granted no entry should relock in 5 seconds if door not opened should relock immediately when open should receive door forced open alarm Door should unlock Alarm should sound Door should unlock Door should unlock Should contact security BOB WINFREY - CALLISON 1420 5TH AVE SUITE 2400 SEATTLE WA 98101 RE: Permit No. D09 -131 3355 S 120 PL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 01/31/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- Department of Community Development Jack Pace, Director 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 01/31/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, : C- Z/VbItt — Bill Rambo Permit Technician File: Permit File No. D09 -131 Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 a Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DEPARTMENTS: pmt/ o Building Division b & N �4 Public Wo s Please Route Documents /routing slip.doc 2 -28-02 • PLAN REVIEW /ROUTING SLIP TUES/THURS ROUTING: APPROVALS OR CORRECTIONS: Structural Structural Review Required ACTIVITY NUMBER: D09 -131 PROJECT NAME: MICROSOFT SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # DATE: 07 -14 -09 Response to Incomplete Letter # Revision # After Permit Issued Pe ° I - - / k 0 Fire Prevention n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) REVIEWER'S INITIALS: �� - N/A -1-1(0-01 Planning Division Permit Coordinator ir DUE DATE: 07 -16-09 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n No further Review Required DATE: Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 08 -13-09 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 CBIC SA5055 10/29/2001 Until Cancelled 01/01/1980 $6,000.00 10/17/2001 6 CBIC SA5055 10/29/1996 10/29/2001 $4,000.00 5 SAFECO INS CO 2570965 10/29/1987 10/29/1996 $4,000.00 4 SAFECO INS CO OF AMERICA 257096583 10/29/198610/29 /1987 3 SAFECO INS CO 2570965 10/29/1985 10/29/1986 2 SAFECO INS CO 257096583 10/29/198310/29 /1985 1 SAFECO INS CO 2570965 04/25/1982 10/29/1983 Name Role Effective Date Expiration Date SCHEELAR, LAWRENCE A 01/01/1980 SCHEELAR, DAVID M 01/01/1980 SCHEELAR, GELARLA (JUDY) 01/01/1980 Untitled Page • General /Specialty Contractor A business registered as a construction contractor with LErI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company KRAUSE /SCHEELAR, INC 4258831243 PO BOX 2018 REDMOND WA 98052 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 578076456 ACTIVE KRAUSI *249P9 CONSTRUCTION CONTRACTOR 10/29/1976 10/30/2010 SHEET METAL UNUSED Business Owner Information Bond Information Page 1 of 2 https: // fortress .wa.gov /lni/bbip /Detail.aspx 08/04/2009