Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D09-137 - MACYS - STORAGE RACKS
MACY'S 551 STRANDER BL D09 -137 Parcel No.: 0223300010 Address: 551 STRANDER BL TUKW Suite No: Tenant: Name: MACYS Address: 551 STRANDER BL , TUKWILA WA Owner: Name: REALTY ASSOCIATES FUND VII Address: 1301 DOVE ST #860 , NEWPORT BEACH CA 92660 Phone: Contact Person: Name: MIKE SORENSON Address: 1100 SW 7TH ST , RENTON WA 98057 Phone: 206 - 818 -4488 Contractor: Name: OWNER AFFIDAVIT - GERALD MARIE Address: 551 STRANDER BL , TUKWILA WA 98188 Phone: Contractor License No: DESCRIPTION OF WORK: ANCHOR RELOCATED PALLET RACKS doc: IBC -10/06 City.' Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Value of Construction: $0.00 Fees Collected: $163.50 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: 0025 * *continued on next page ** Permit Number: D09 -137 Issue Date: 07/29/2009 Permit Expires On: 01/25/2010 Expiration Date: D09 -137 Printed: 07 -29 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City d*Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructio or `e perfo I ce of work. I am authorized to sign and obtain this development pe t. f Signature: �� Date: / —9 ( G q doc: 18C -10/06 Print Name: CD 0-4 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Permit Number: D09 -137 Issue Date: 07/29/2009 Permit Expires On: 01/25/2010 Date: D09 -137 Printed: 07 -29 -2009 Parcel No.: 0223300010 Address: 551 STRANDER BL TUKW Suite No: Tenant: MACYS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 9: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D09 -137 Status: ISSUED Applied Date: 07/21/2009 Issue Date: 07/29/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 12: Maintain fire extinguisher coverage throughout. 13: Clearance between ignition sources, such as light fixtures, heaters and flame- producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) D09 -137 Printed: 07 -29 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us • 14: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 15: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinidered areas of buildings. (IFC 315.2.1) 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10 /06 * * continued on next page ** D09 -137 Printed: 07 -29 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: C doc: Cond -10/06 D09 -137 Date: ordinances governing or local laws regulating Printed: 07 -29 -2009 Company Name: Mailing Address: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htip://wwwci.tukwila.wa.us Building Permit No, q- ( 7 Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 551 S r4 e P Mwd Tenant Name: /'IQ G yx Property Owners Name: �Qr'14[_ yfSSOcI CtdQS Mailing Address: l 36 ( jev'll- 57`: 44. 030 CONTACT PERSON -- who do we contact when your permit is ady to be issued Name: /00<-0— 5o t'tt -n S �•+ Mailing Address: l l 00 S W 7 S T E -Mail Address: WI Core S oil wk S . C *h GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) .—ra e-idesr is.); ezi Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: ail Address: H: \Applications\Forms- Applications On Line \2009 Applications \1 -2009 - Permit Application.doc Revised. 1 -2009 bh King Co Assessor's Tax No.: )I QL p r i V 1 d 330 0010 Suite Number: Floor: New Tenant: ❑ Yes [No CA- 9,--2.o State Zip Day Telephone: ao 6 - 8' n , i1 w'4 ',pas 7 City State Zip Fax Number: Lj - gag A State Zip City Day Telephone: Fax Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record State Zip City Day Telephone: Fax Number: ENGINEER OF RECORD All plans must be wet stamped by Engineer of Record Company Name: Fa Lk 3eSf4n + m 1'1 , 9 • //� Mailing Address: / v - �. ro d SG / c:20 V GIP.hd 65/- City Rig Zip Contact Person: �'�`l O�4vl Day Telephone: & rg c X2(0 E -Mail Address: e Fax Number: RI & BYO , 3 3 Page 1 of 6 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ O © Existing Building Valuation: $ Scope of Work (please provide detailed information): • V' L Ciro-La J s , e + �+,.� - a tea) + $ 7p l2 rw►a..i 7 r 1 o (4J? s' , k t (s , irzc � c4 Ti r - tj Will there be new rack storage? ❑ Yes Number of Parking Stalls Provided: Standard: Compact: H.\ApplicationsWorms- Applications On Line\2009 Applications1l -2009 - Permit Application. doc Revised, 1 -2009 bh No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 1$t Floor 2nd Floor 3`° Floor Floors Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck erior Remodel v Addition to Existing Structure Type of Construction per ;LBC Type of Occupancy per IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Handicap: Will there be a change in use? ❑ Yes [ No If "yes ", explain: FIRE PRO CTION /HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes iii?" If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO p AGENT: Signature: Date: 772 / /U Print Name: t" kit 6 r tt.Sa Mailing Address: ((X' - W.. , 7 S% Date Application Expires: Date Application Accepted: H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application. doe Revised. 1 -2009 bh Day Telephone: 06 &l. " eifizie0 e n i c . n C4 9 O5 7 Zip City State Staff Initials: Page 6 of 6 Parcel No.: 0223300010 Permit Number: D09 -137 Address: 551 STRANDER BL TUKW Status: PENDING Suite No: Applied Date: 07/21/2009 Applicant: MACYS Issue Date: Receipt No.: R09 -01133 Initials: WER Payment Date: 07/21/2009 11:32 AM User ID: 1655 Balance: $0.00 Payee: MICE SORENSON TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 00336A ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Account Code Current Pmts 000/322.100 000/345.830 640.237.114 RECEIPT 163.50 120.00 39.00 4.50 Total: $163.50 Payment Amount: $163.50 P I,YMENT RECEIVED doc: Receiot -06 Printed: 07 -21 -2009 Project: Inn ACL -1 s Type of Inspection: 1=l NI A I Address: 5 1 si2AN) e IL Date Called: Special Instructions: 4e4 ,64,9 Date Wanted: Requester: Phone No: . LO — 730 - 1 3 2 1 C ) INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION f" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 3 .Do -►3 A Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: jji 01, C9KpV-rE f- itz.- e971)1,ert Inspector: it � Date: 611 0 $60.00 ins $60.00 REINSI�ECTION FEE REQUIRED. Prior p ecti n, m , Jst be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinsp ction. (Receipt No.: Date: Project: filAC Y Type of Inspection: Fi h"/9 L. Address: 5 S j,2 <1NV � e Date Called: Special Instructions: Date Wanted: 83 _' / q- Qc- p.m. Requester: Phone No: �7 2 /3 U C 2 r/ 3 O" �3J 1 9 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12 ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 J Approved per applicable codes. Corrections required prior to approval. COMMENTS: &QQ__k A (2— 5 ? �� ` � � s pe.� ., tD , . Date:. r 4 J 1 6 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinseection Receipt No.: ,Date: P?oject: TylA of Inspection: , Address: 55i s! 2AJAC? Date Called: Special Instructions: r e� " �3p— 3 16 O+ 9 O! s 4 V Date Wanted: 3 p — a:m. m. Requester: (Y ; Ke i kw1'3 uNA.a Phone No: ) _A - g8P) INSPE ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -36 ❑ Corrections required prior to approval. COMMENTS: �a P u.1 1. Qom. ie-.< /I REINSPECTION FEE t 6300 Southcenter Blv Date: " 3 QUIRED. Prior to inspection, fee must be , Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Fireproofing Aggregates Shotcrete Concrete Masonry A s p h a l t R o o f i n g P i I i n g S t e e l S o i l s W o o d August 25, 2009 File: 09 -206 Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Address: Permit No:: Macy's 551 Strander Blvd. +E) j -1S7 RECENE° 'AUG 26 2009` CO`t+na« D EVELOPl1 This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and copies of our reports are attached. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and /or verbal or written instructions from the Engineer of Record. Sincerely. A.A.R. TESTING LABORATORY, INC. Kimberle Anderson President CC: Northwest Handling Systems, Inc. -Thom Drew A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND MATERIAL TESTING NATIONALLY ACCEPTED LABORATORY Tel: (425) 881 -5812 Fax (425) 881 =5441 • 7126 180th Ave. NE • P.O: Box 2523 • Redmond, WA 98073 A.A:R: Testing Laboratory, inc. 7126 180th Ave.N.E:,.Park 180, Suite C101, Redmond, WA 98052 `; Phone 425.881.5812 Fax 425.881.5441 Client: NorthWest Handling Systems, Inc. 1100 SW 7th St. Renton, WA 98055 -2939 Contact: Thom Drew Inspection Performed: Proprietary Anchors Date: 8/7/2009 Observed installation of new pallet racking for this permit. Hilti KB -TZ 1/2" x 4 1/2" anchor bolts are being installed in accordance with manufacturer's recommendations. Calibrated torque wrench was used to verify that bolts achieved 40 ft/lbs per ESR 1917. Work has been completed up to the tunnel from the eastside. AAR to return for further construction and inspection. Distribution: RECEIVED AUG 2 6 2009 p De tact Field Report Report 50086 pQ�NT [V Distribute Client ❑ Distribute Contractor Distribute Engineer H] Distribute Owner Distribute Municipality ❑ Distribute Other f Distribute Architect ❑ Distribute Other Project Number: 09 -206 Permit #: D09 -137 Project Name: Macy's Address: 551 Strander Blvd. Time: 12:45:00 PM Temperature: 65 Inspector: Bosma, Rory Reviewed by: Mike Blackwell All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden Field Report Report #: 50777 A.A.R. Testing Laboratory, lnc. 7126 180th Ave.N.E., Park 180, Suite 0101, Redmond, WA 98052 Phone 425.881.5812 Fax 425.881.5441 Client: NorthWest Handling Systems, Inc. 1100 SW 7th St. Renton, WA 98055 -2939 Contact: Thom Drew Inspection Performed: Proprietary Anchors Date: 8/24/2009 Observed installation of remaining pallet racking for this permit on sheet D -1. Hilti KB -TZ W by 4W expansion anchors were used according to manufacturer's recommendations. Calibrated torque wrench was used to verify 40 ft/lbs torque at each bolt. Work was found to conform to ESR 1917. Distribution: Time: 12:15:00 PM ,■ Distribute Client J Distribute Contractor H Distribute Engineer J Distribute Owner Id,' Distribute Municipality 11 Distribute Other Distribute Architect Distribute Other Project Number: 09 -206 Permit #: D09 -137 Project Name: Macy's Address: 551 Strander Blvd. Temperature: 70 Inspector: Bosma, Rory Reviewed by: Mike Blackwell All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden e Material Han ling Experts FILE COPY ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT RACK INFORMATION SUPPLEMENT SITE ADDRESS: 551 Strander Blvd TENANT NAME: Macy's DATE: July 21, 2009 APPLICANT: Mike Sorenson / (206) 818 -4488 1. Load application and rack configuration drawings attached. 2. Attached plans and engineering detail the rack locations, dimensions, and specifications. 3. Stamped engineering calculations attached. 4. Inspections will be scheduled as instructed. 5. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 6. Commodities stored in racks: Store fixtures. Constructed of metal, wood, and glass. Stored on wood pallets. Some band only shrink wrapping. 7. Sprinkler System Information: Wet system. Static psi: 145. Residual psi: 135. 8. Building exits indicated on attached drawings. ;q% l37 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 3 2009 City of Tukwila 1100 SW 7th UILDING DIVISION Renton, WA 98055 (425) 255 -0500 ph (425) 228-6946 fax RECEIVED JUL 2y200 - ERNIIT CENTER BY..i G. OHANIAN DATE . 7 -17 -09 SUBJECT STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: MACY'S 551 STRANDER TUKWILA, WA. 98188 PER IBC 2006 EDITION STORAGE RACKS CAPACITY: 2000 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -14298 RAdK & EN(4INEERINd do. 412 wEptr BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 ea.....•�9� i1Mn .. EXPIRES 12 - - p09- 137 FILE COPY SHEET NO. 1 JOB NO.. RD - 14298 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 3 2009 City of Tukwila BUILDING DIVISION RECEIVED JUL 212009 PERMIT CENTER • BY 1 G. OHANIAN DATE. 7 - 17 - 09 SUBJECT a \ \ O O \ \ BEAM M= 108 "x1.7 K = 23-K 8 S R = 3 "K = .76 <.95 A— 5xWxL — 3 „ < 108 = .6„ 384x1, xE 180 V— )I { 1 SEISMIC DESIGN Sdsxl x W Rx1.4 WORKING STRESS W= D.L. +2 /3 L.L. LOAD PER COLUMN P= 2X2 K =2 K 2 COL W =.1 0. 2x2/3 1.4 K V — .93x1.4— 16 LONG. 6x1..4. V = .93x1.4 =. SV TRAN. `f X 1 •4 108" FRONT VIEW RACK DEN1(N & EN(INEERIN( CO. 412 WEBT BROADWAY, BUITE #204 ( LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 N N In 2000 #/ LEVEL +25% IMPACT 1700 #1 BEAM IBC 2006 RMI SPECS 1 =1 NO PUBLIC ACCES R =4 BRACED R =6 MOM. CONN. Sds =.94 0\ N N ASCE7 -05 SEC. 15.5.3 1 42" T T f SIDE VIEW I, =2.3 S,=.95 F Y= 50 KSI. LONGIT. SEISMIC N al 0 \ \ 108" N r ^4 1 TUNNEL BAY Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.45 Longitude = — 122.24 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 = Fv x S1 Site Class D — Fa = 1.0 ,Fv = 1.52 Period Sa (sec) (g) 0.2 1.405 (SMs, Site Class 0) 1.0 0.730 (SM1, Site Class 0) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.45 Longitude = — 122.24 Design Spectral Response Accelerations SDs and S01 SDs = 2/3 x SMs and SD1 = 2/3 x SM1 Site Class D — Fa = 1.0 ,Fv = 1.52 Period Sa (sec) (g) 0.2 0.936 (SDs, Site Class 0) 1.0 0.486 (SD1, Site Class D) SHEET NO. 2 JOB NO RD - 14298 BY .s G. OHANIAN DATE. 7 -17 -09 SUBJECT COLUMN ANALYSIS M x- f 3 t =.09 M 1 COMBINED STRESS RATIO P + M = 2 + 2 = . 9<1 Pa ax BASE PLATE 5x3 1/4 "X3/16" ANCH. TENSION = 0 ANCHOR SHEAR = .2 K Fy =50 KSI A =.8 S =.8 r =1.2 r =1.1 (1) -1/2 "0 HILTI KWIK BOLT TZ ANCHOR ESR -1917 OR APPROVED EQUAL. (SPECIAL INSPECTION IS REQ'D) MOMENT AT BEAM CONNECTION 7/16 "o RIVET A =.1 Fy = 79 KSI Va = .1x79x.4 3 Ma =3Kx4 "x1.33 = 16" K CONN. RAdK DEOI(N & ENdINEERIN(4 d0. 412 WET BROADWAY, BUITE #204 LENDALE. dA. 91204 TEL:(818)240 -3810 FAX:(818)240-3813 2 PIN CONN. KI 96x1.7 = 136 rx — 1.2 KI 52 _47 r _ y — 1 — Max =Sx•Fb = 24 "1( Fe =( K � j 2 = 16 F = 16 KSI P =F xA= 13 K P _ Pn _ 7K P a — 1.92 — SHEET NO 3 JOB NO. RD -14298 BY G. OHANIAN DATE . 7 -17 -09 SUBJECT OVERTURNING TOP LEVEL 100 % LOADING M OT = .23 = 51 "K MOT' 36Kx192 " =69 " K MR = 1.4 " = 59 "K MR= 2.2Kx21' =46 "K NO UPLIFT UPLIFT =(69- 46)/42 =.6 K LOAD TO DIAGONAL P = .23Kx2x42 = .6 K F Y =50 KSI A =.31 r =.48 0 =.74 L= 56" CHECK WELDS CHECK SLAB 2200 2 . 2 a' 1000 — F 11.2 KSI P = 3.5 K 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.707x70x.3 = 5.7 K 2.2x144=317 °" =18" M= ( 1 2 ) 2 x 1000x 2 x12= 1500 "# S= 12x62 = 72 6 1500 = 30 <1.6 J2500 =80 72 RAdK DEOI(N & EN(INEERIN( do. 412 WE BROADWAY, f UITE #204 LENDALE, CA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 BOTH SIDES TYP. 2200 # SHEET NO 4 JOB NO. RD -14298 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL Documents /routing slip.doc 2 -28 -02 • I Win COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D09 -137 PROJECT NAME: MACYS SITE ADDRESS: 551 STRANDER BL X Original Plan Submittal Response to Correction Letter # DATE: 07 -21 -09 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: D din iD vision Fire Prevention [ Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 07-21-09 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions DATE: Not Applicable DUE DATE: 08-1 8 -09 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: July 29, 2009 Mr. Gerald Marie Macy's 551 Strander Boulevard Tukwila, WA 98188 RE: New Racking systems, non structural wall installation Dear Gerald: On behalf of the Landlord, the Realty Associates Fund VII, LP, we are providing our written approval for Macy's to complete the interior racking, and to hire a licensed bonded contractor to complete the installation of the new wall(s) within the Premises. We understand that the Contractor, and or Macy's will be obtaining a permit from the City of Tukwila with respect to this construction work and new racking system. If you have any questions or comments, please call me directly at (206) 398 -2271. ncerel ted, CPM VP, Property Services JCL: Dg Cc: Lease File • • GVA Kidder Mathews Worldwide Real Estate Solutions Property Management Services 601 Union Street, Suite 4720 Seattle, Washington 98101 Tel: 206.296.9600 Fax: 206.296.9629 www.gvakm.com • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 FAX (206) 431 -3665 E - mail: tukplanaki.tukwila.wa.us AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING Cie - [please print name] , states as follows: Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 -0179 Planning Division 206 431 -367o PERMIT NO: i i O 1 13i 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform r work. 1 Notary Public State of Washington Al KIM MENDOZA My Appointment Expires Jun 15, 2019 Owner Owner's Signed and sworn to before me this 2 NOT ,20 PUBLIC ii and for the State of Washington Residing at i K q , County Name as commissioned: ,4 Vtn RPAAdOZck My commission expires: ` ui4 1T 2f)./.3 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12. Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. 42X108 42X108 42X108 42X108 42X108 42X108 SHEET DESCRIPTION PALLET RACK PERMIT SCALE AS SHOWN DATE 7/16/09 DRAWN BY KEITH WERNER REVISIONS NORTHWEST 1100 SW 7TH STREET RENTON WA 98055 (425) 255 -0500 ANCHORAGE PORTLAND SPOKANE EUGENE YAKIMA PROJECT TITLE MACY'S TUKWILA, WA NOT PUBLISHED. ALL RIGHTS RESERVED. THESE DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS, AND ARRANGEMENTS THEREBY ARE AND SHALL REMAIN THE PROPERTY OF NWHS. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISCLOSED OR DISTRIBUTED TO OTHERS, SOLD PUBLISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF NORTHWEST HANDLING SYSTEMS. EXPIRE 12 -2s - i s'�� 1 3/4" t \ \: \ n •I' / — n J n I � 0 RcNI 1 us /5 L BOTH SIDES TYP> 1/8 V1.5" 'FE; � I I I Al Qn CV — I I I A ��J i ii ff 2 3/4 1 /8 P" ,, 3 V t =.07" A O 14 C CC Q •�� M - _ . _ - _ I SEC. A—A CAp AC - j (D d ° 1 8 Fri .5- ___— f I 1 I ` . d a L • 1 I a ° �d 44 ° ° d C n !1! I r ---- � � 16,. I I „9 - - -- — l I I ji 3 1 /4" t =3/16" r _______ --� SEC. S —B + «1. (1) - /2"o ANCHOR PER BASE PLATE 3 1/4" EMB. (SEE NOTE 4) 7/16 "0 RIVET ASTM A354 -79 t= 3/16" BRACE TO COLUMN CONN. 1 BEAM CONNECTOR 2 BASE PLATE DETAIL (3; GENERAL CONFIGURATION (4 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. — 1 FILE COPY Permit No. Plan review approval is subject to errors Approval of construction documents does the violation of any adopted code or of approved Field Cop : • cor :"' f ons By ^ :, and omissions. not authorize rdinance. Receipt is acknowledged: Date: • cl City Of 1Ukwila BUILDING DIVISION 108" 42" 108" / II NOTES: 1- DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE IBC 2006 EDITION 2 -STEEL FOR ALL SHAPES FY =50 KSI. ASTM A570 -85 GR,50 (EXCEPT AS NOTED) 3 -ALL WELDED CONSTRUCTION IN A SHOP OF AN APPROVED FABRICATOR (E70XX ELECTRODES) 4- ANCHORS WEDGE TYPE, HILTI KWIK BOLT TZ ESR -1917 OR APPROVED EQUAL (SPECIAL INSPECTION IS REQUIRED) 5- CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 6- STORAGE RACK CAPACITY 2000 # / LEVEL 7 -ALL RACK INSTALLATIONS AND RACKS MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA SHOWING THE PERMISSIBLE UNIT LOAD OF 2000 # /LEVEL 8- STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1/2" IN 10' -0" OF HEIGHT 1 / ...4. cn �\ o !l I[ 0 x N \ REVIEWED FOR 3ODE COMPLIANCE IV ED JUL 1 2009 �„ PERMIT CENTER APPROVED I JUL 2 3 Z009 A L A .4. o i J \ 0 r— R N to R N "' O 00 O City Of ru ti1 BUILDING ii IVI 1Ol� Q Z D REV. ON REVISI 4- W "s'f � r DATE 1 � �Hq RACK 9 � � SCALE: NONE DRAWN BY: A.KH. DATE: 7 -17 -09 f A I R 9 { V tV � •� F c 99442 rsr A S S (>\, =. i PROJECT: U V II ,4".. I I ' 551 STRANDER, TUKWILA, WA. STORAGE RACK DETAIL JOB N0. RD -14298 SHEET N0. FRONT VIEW SIDE VIEW TUNNEL BAY EXPIRE 12 -2s -