Loading...
HomeMy WebLinkAboutPermit D09-192 - WESTFIELD SOUTHCENTER MALL - BRITE SMILES - TENANT IMPROVEMENTBRITS SMILES 426 SOUTHCENTER MALL D09 -192 Parcel No.: 6364200010 Address: 426 SOUTHCENTER MALL TUKW Suite No: Tenant: Name: BRITE SMILES Address: 426 SOUTHCENTER MALL , TUKWILA WA Contractor: Name: EXPRESS CONSTRUCTION SERVICES Address: 851 SE SOMERS DR , SHELTON WA 98584 Phone: 360 - 427 -1581 Contractor License No: EXPRECS918N5 doc: IBC -10/06 Cityef Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us DEVELOPMENT PERMIT Owner: Name: WEA SOUTHCENTER LLC BSIP Address: TOTAL 13 PARCEL NUMBERS , 2010 NEW PLAT MAJOR 920247 00000 Phone: Contact Person: Name: KEITH SMITH Address: 1725 WESTLAKE AVE N SUITE 210 , SEATTLE WA 98109 Phone: 206 - 713 -4076 Permit Number: D09 -192 Issue Date: 10/13/2009 Permit Expires On: 04/11/2010 Expiration Date: 08/25/2011 DESCRIPTION OF WORK: TENANT IMPROVEMENT, NEW FINISHES, ADD (4) VANITY SINKS, NEW CHECKOUT COUNTER, ADD (2) LIGHT TRACKS AND (1) PENDANT FIXTURE Value of Construction: $15,000.00 Fees Collected: $592.89 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: II-B Occupancy per IBC: 0019 * * continued on next page ** D09 -192 Printed: 10 -13 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: City oftI'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206-431-3665 Web site: littp://www.ci.tuicwila.wa.us N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and e ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or•erformance gfwork. I am auylprized to sign and obtain this development pe t. .J` C c, Date: Signature: Print Name: doc: IBC -10/06 Permit Number: D09 -192 Issue Date: 10/13/2009 Permit Expires On: 04/11/2010 Date: loti This permit shall become n uli and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -192 Printed: 10 -13 -2009 Parcel No.: 6364200010 Address: 426 SOUTHCENTER MALL TUKW Suite No: Tenant: BRITE SMILES 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D09 -192 Status: ISSUED Applied Date: 09/10/2009 Issue Date: 10/13/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDI'T'IONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, doc: Cond -10/06 D09 -192 Printed: 10 -13 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Gates serving the means of egress system shall comply with the requirements of the International Fire Code. Gates used as a component in a means of egress shall conform to the applicable requirements for doors. (IFC 1008.2) 24: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 25: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 26: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 doc: Cond -10/06 D09 -192 Printed: 10 -13 -2009 r • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 27: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 28: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 29: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (EEC 901.4) 30: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 31: All new sprinlder systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 32: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051.(All fire alarm components to be tied to the main mall fire alarm control panel.) 33: Local U.L. central station supervision is required. (City Ordinance #2051) 34: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 36: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 37: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 38: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1)(Post address on storefront per approved Westfield specs.) 39: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 40: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 41: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed doc: Cond -10/06 D09 -192 Printed: 10 -13 -2009 description of intended use. • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 42: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes such condition or violation. 43: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila (206)575 -4407. * *continued on next page ** doc: Cond -10/06 D09 -192 does not imply approval of Fire Prevention Bureau at Printed: 10 -13 -2009 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 D09 -192 Date: ordinances governing or local laws regulating Printed: 10 -13 -2009 Tenant Name: CITY OF TUKWILL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup://www.ci.tulovila.vva.us 426 Southcenter Mall, Tukwila, WA Brite Smiles Name: Keith Smith ksmith @smithco.org E -Mail Address: Express Construction Services Craig Lawson Keith Smith na City City I Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. IG0'- I 0 4 Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: (L 3 l0 L I )-o- 0010 Site Address: Suite Number: 1000 Floor: 1st New Tenant: Property Owners Name: Westfield Mall - Southcenter Mailing Address: 633 Southcenter Mall Parkway, Tukwila, WA Zip State CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: 206-713-4076 Mailing Address: 1725 Westlake Ave. N. , Suite 210 Seattle, WA 98109 Zip State Fax Number: 206 - 464 -0700 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: 851 SE Somers Dr. , Shelton, WA 98584 Zip City Contact Person: Day Telephone: 360-427-1581 E -Mail Address: craig@expressconstructionservices.com Fax Number: 360 - 427 -1118 State Yes ❑ ..No Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: smith co. LLC Mailing Address: 1725 Westlake Ave. N. , Suite 210, Seattle, WA 98109 City State Zip Contact Person: Day Telephone: 206-713-4076 E -Mail Address: ksmith @smithco.org Fax Number: 206- 464 -0700 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:'Applications\Forms- Applications On Line' -2006 - Permit Application.doc Revised: 9 -2006 bh State Zip Page 1 of 6 BUILDING PERMIT INFO ION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 15 , 000 Existing Building Valuation: $ Scope of Work (please provide detailed information): new finishes, add (4) vanity sinks, new checkout counter, add (2) light tracks and (1) pendant fixture Will there be new rack storage? El Yes .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): na Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: na Compact: Handicap: Will there be a change in use? ❑ Yes ® No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ® Sprinklers El Automatic Fire Alarm ❑ None El Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:'Applications\Forms- Applications On Line U-2006 - Permit Applicntion.doc Revised: 9 -2006 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor 1,790 1,790 na na II -B M 2 " Floor 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFO ION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 15 , 000 Existing Building Valuation: $ Scope of Work (please provide detailed information): new finishes, add (4) vanity sinks, new checkout counter, add (2) light tracks and (1) pendant fixture Will there be new rack storage? El Yes .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): na Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: na Compact: Handicap: Will there be a change in use? ❑ Yes ® No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ® Sprinklers El Automatic Fire Alarm ❑ None El Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:'Applications\Forms- Applications On Line U-2006 - Permit Applicntion.doc Revised: 9 -2006 bh Page 2 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks y Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping I Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION T.B.D. Company Name: Mailing Address: State Zip City Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 2 , 500 Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): add (4) new vanity sinks Building Use (per Int'I Building Code): Occupancy (per Int'l Building Code): M Utility Purveyor: Water: Tukwi Sewer: Tukwi Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q: \Applications\Fonns- Applications On Line' -2006 - Permit Application.doc Revised: 9 -2006 bh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). Date Application Accepted: 9 - -10-09 Q:V+pplications\Forns- Applications On Line' -2006 - Permit Application.doc Revised: 9 -2006 bh City 09.10.09 Date: 206 - 713 -4076 Day Telephone: Print Name: Keith L . Smith Mailing Address: 1725 Westlake Ave. N., Suite 210, Seattle, WA 98109 State Zip Date Application Expires: 3- (p - I0 Staff Initials: Page 6 of 6 RECEIPT NO: R09 -01594 Payment Date: 10/13/2009 User ID: 1655 Total Payment: 648.10 Initials: WER Payee: EXPRESS CONSTRUCTION SERVICES SET ID: 1013 SET NAME: BRITE SMILES SET TRANSACTIONS: Set Member D09 -192 EL09 -0575 PG09 -106 TOTAL: ACCOUNT ITEM LIST: Description of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: /hvww. ci. tukw ila. wa. us Amount 361.10 130.00 157.00 361.10 SET RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 1029 648.10 TOTAL: 648.10 BUILDING - NONRES ELECTRICAL PERMIT - NONR PLUMBING - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000.322.101.00.0 000.322.103.00.0 640.237.114 356.60 130.00 157.00 4.50 TOTAL: 648.10 PAYMENT RECEIVED Parcel No.: 6364200010 Permit Number: D09 -192 Address: 426 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 09/10/2009 Applicant: BRITE SMILES Issue Date: Receipt No.: R09 -01421 Initials: User ID: WER 1655 Payee: KEITH SMITH • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 9850 231.79 Authorization No. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES RECEIPT Account Code Current Pmts 000/345.830 231.79 Total: $231.79 Payment Amount: $231.79 Payment Date: 09/10/2009 11:34 AM Balance: $361.10 AY E , T ECEIVE doc: Receiot -06 Printed: 09 -10 -2009 COMMENTS: - ?EA. i ( 4. f Vie /F 1 l Address: L.-1 2—C° ScAt{- kec.a) y YY i-16Tg.. i 111 PC 6.:te 1 I -- Pei..... ;-k O.(4'2 'C tAr Ldnt,.r& i -1 / Nf f , rJr-k ►1,a i 1 is. omit M• 'q Jk l l uW S. ( V a.m. v NI t'1%.1 , A SP ai vrlc psi ....?-1 l/ i-fiw � %thMlk be 14ktP4 -t-o. IW,s i o t t rk Phone No: 36,o — 7 C t 1 — 912 3 I / \ j Prot -tit: Type of Inspection: l Address: L.-1 2—C° ScAt{- kec.a) y YY Date Called: 1 Special Instructions: Date Wanted: 10- 30 -09 a.m. v Requester: Phone No: 36,o — 7 C t 1 — 912 3 INSPECTION RECORD Retain a copy with permit \ - c l z -. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 N IX Approved per applicable codes. 0 Corrections required prior to approval. nspe to j: .00 REINSPECTION IIEE REQUIF ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., S to 100. Call to schedule reinspection. $6 Re t No.: 1A., 'Date: ate: iu Project: Type of Inspection: Address: l i t Us cry 6,4�. /40'7/ pate Called: Special nstructions: Date Wanted: m. ,ia Requester: Phone No: Z INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 D Approved per applicable codes. Corrections required prior to approval. COMMENTS: n 7 -76 .7 b.- f/' i) Z r ro• /".; r /47%47 - ❑ E $60.00 REINSP i FEE REQUIRED. Prior to inspection, fee must be paid at 6300 S. u hcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: / / rr /- �N0`- �(/ ,,e(l „ 4 ,) € /r i ioi / 1 — NO C{1 /XJ/1 &)i'lktS ✓' �Oi r i , a�r #4ry errv�adA1 nay/ hp /SSd /A -e .J /b / --/a /72, - An/.f4 / / )4 4 / d TPi rioit ,-p /idn/ - /- 3 rIi#- r'P 11' Special Instructions: Date Wanted: /v -2_3 —0 S a.m. COP Requester: "----, Project, /'� f�� / /YS Type of I�ns .ection: /�irv/3 / Address: ,�,, - C7 2 ,s- /M(c ,0i)y//+"/ /'7 Z.,/ Date Called: Special Instructions: Date Wanted: /v -2_3 —0 S a.m. COP Requester: Phone No: .360-7`5/- 9/7 �—, INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. 51CA:erections required prior to approval. 0 REINSPECTION FEE REQU)RED. Prior to inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: / 0— � Date: Project : ei ic 5.1-7; /$ � /.tt Type of Inspection: t ,Qe A.A/A / Fire Alarm: Address: 4/20 Suite #: '9 . C . Add/ Contact Person: C82 A.6y 44w5e.,1 /04/F5, 5 Special Instructions: Pre -Fire: Phone No.: -3400- 7 c , /_ 9773 Permits: Needs Shift Inspection: 1 , e5 Sprinklers: � /.tt Fire Alarm: Hood & Duct: Monitor: )49/ `Jcg Pre -Fire: Permits: Occupancy Type: 4 • INSPECTION NUMBER Approved Per applicable codes. . . w INSPECTION RECORD Retain a with permit CITY OF TUKWILA FIRE DEPARTMENT ..b9 —(9L PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 ri Corrections required prior to approval. COMMENTS: . Pre 4 0k__ G.. /1 eerok '&44 oved ea 6101 /ace, 6 ■ fe, (cz4dv -4S flh Inspector: ' jI- IAA S"`/ Date: /o/z4, rs.. n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department Call to schedule a reinspection. Word /Inspection Record Form orm.Doc 1/13/06 T.F.D. Form F.P. 113 Project: � .14z S � I� Type of Inspection: Address: Liz G2 Suite #: S .0 . wiz, If Contact Person: C EA i6 L,q t,1 50 Special Instructions: • Phone No.: Permits: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: • Pre -Fire: - Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 I I Appro9ed per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS Corrections required prior to approval. COMMENTS: n11? i Leo..6e 4 G C(Q 4'7v 4 V' i( ■/P4 C s c 16 1 4 � € f J; C .' 5 qle S' 5e5i 5 . t./A . 94 5551 Inspector: -- m u 5 - y Date: /07 -47 • Mrs .. • I $80.00 REINSPECTION FEE REQUIRE D. You will receive an invoice from t e City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project Info Project Address 426 Southcenter Mall Date 9/10/2009 Tukwila, WA 98188 For Building Department Use FILE COPY 101 Applicant Name: smith smith Applicant Address: 1725 Westlake Ave. N, Suite 210 Applicant Phone: Seattle, WA 98109 Project Description ❑ New Building ❑ Addition Ri Alteration Indicate controls (Sections 1513) including commissioning stock room r Plans Included requirements on plans. Compliance Option 0 Prescriptive Q Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft 2.,, Area in ft Allowed x Area 101 retail 1.50 1641.0 2461.5 103 stock room 0.50 100.0 50.0 104 toilet 0.80 49. 39.2 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 2550.7 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 101 A - CANOPY MTD. LINEAR FLUORESCENT 6 39.0 234.0 101 8 - CANOPY MTD. LINEAR FLUORESCENT 4 64.0 256.0 101 C - TRACK 14 50.0 700.0 101 D - RECESSED COMPACT FLUOR. 10 32.0 320.0 101 Dl - RECESSED SPOT 2 75.0 150.0 101 D2 - RECESSED COMPACT 5 60.0 300.0 D3 - MONOPOINT 8 50.0 400.0 F - 2 FT FLUOR. STRIP 1 13.0 13.0 Fl - 4 FT FLUOR STRIP 4 32.0 128.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2501.0 4 Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and o t_ her criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual REVI � trti . - track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, r�r tzs ~ * nt limiting devices or of the transformer. CODE exempt lighting, note section and exception number, and leave Watts /Fixture blank. APPROVED OCT o 9 2009 4 City of Tukwila BUILDING DIVISION tO9 i'i RECEIVED SEP 10 2009 PERMIT CENTER Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 426 Southcenter Mall 'Date 9/10/2009 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations E - 1 no 1513.2 Area controls Maximum limit per switch no 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans no 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timer w /backup Indicate location E-1 no (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations E-1 no 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 IMax. watts Ilndicate watts for each exit sign I 1 31 LIGHTING POWER ALLOWANCE (Section 1530 - 1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture no 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yes I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) yes I 1540 (Transformers 'Indicate size and efficiency IE - 2 I 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: September 28, 2009 Keith Smith 1725 Westlake Ave N Suite 210 Seattle, WA 98109 RE: CORRECTION LETTER #1 Development Permit Application Number D09 -192 Brite Smiles — 426 Southcenter Mall Dear Mr. Smith, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -1763 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician end File No. D09 -192 • City of Tukwila Department of Community Development Jim Haggerton, Mayor W:\Pennit Center \Correction Letters\2009\D09 -192 Correction Letter #1 DOC Jack Pace, Director Ann Cnnthr.ontor Rnrrlov,rd Cnito inn o TrrPIA/ih 1A/2chinatnn OR1RR o Phnno• MA- 421 - 2A7/1 e Pole- MA- 421 -2AA Building Division Review Memo • • Date: September 18, 2009 Project Name: Brite Smiles Permit #: D09 -192 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Occupant load numbers and calculations on the cover sheet and egress plan are inconsistent. Please revise sheets to show consistency. 2. On the means of egress plan (A -l.1) a "Demo Room" on the occupancy schedule is indicated, however not shown on the plan. Please name all areas and rooms to be consistent with the rooms indicated on the Mean of Egress notes. 3. Note Key # (3) on sheets A -4 and A -4.1 indicates Elevation A /A -1.1. That detail cannot be located. Please clarify. 4. The door #7 on the door schedule indicates a panic bar with alarm. The door #2 to the corridor is also a panic bar with alarm. Since the door #7 is the access to the office and storage, is it the intent for the alarm to be on that door as well, or is the intent to be a plain panic bar without an alarm? This is for clarification only; a change is not required however it seamed problematic for the tenants operation. The notes shall need to include a lever handle on this door to gain access back into the tenant space from the office /storage area, which also may prove problematic with the alarm setup. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: D09 - 192 DATE: 09 -30 -09 PROJECT NAME: BRITE SMILES SITE ADDRESS: 426 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works Complete Comments: REVIEWER'S INITIALS: • u APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 110 PERMIT COORD COPY/ PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Planning Division Permit Coordinator DUE DATE: 10-01 -09 TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required n DATE: Not Applicable Approved ❑ Approved with Conditions I I Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: n Permit Center Use Only . INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: DUE DATE: 10-29-09 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERK SPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D09 -192 DATE: 09 -10 -09 PROJECT NAME: BRITE SMILES SITE ADDRESS: 426 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued EPART ENTS• uing Divi ion /� Pubc Wo s v' i9-01 -01 Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) .2r Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required u No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Fire Prevention Planing Division Permit Coordinator DUE DATE: 09 -15 -09 DUE DATE: 10 -13 -09 Approved ❑ Approved with Conditions U Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only 431721. CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 v • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 09.29.09 Plan Check/Permit Number: D01 -192 O Response to Incomplete Letter # O Response to Correction Letter # 1 O Revision # after Permit is Issued O Revision requested by a City Building Inspector or Plans Examiner Project Name: Brite Smiles • REVISION SUBMITTAL SEP 3 0 1 009 P ERMH . 0 � R Project Address: 426 Southcenter Mall, Space 1000, Tukwila, WA Contact Person: Keith Smith Phone Number: (206) 713 -4076 Summary of Revision: Revised cover sheet, occupancy calculations to match egress plan revised Sheet A-4 and A -4.1 note deleted Revised room names to match floor plan, and means of egress calculations, Sheet A -1.1 revised hardware conflicts with rear doors, sheet A -1 Sheet Number(s): T -1, A -1, A -1.1, A -4, A -4.1 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: &/' Entered in Permits Plus on H:\Applications\Fonns- Applications On Line\2009 -08 Revision Submittal.doc Created: 8 -13 -2004 Revised: 8-2009 September 29, 2009 Allen Johannessen City of Tukwila Building Department Tukwila, WA Re: CORRECTION LETTER #1 Permit Application Number D0,11- I 92 Brite Smiles Dear Allen, • th co . I Below is the responses to your correction letter dated September 18, 2009. Architecture I Design I Planning I Retail I. "Occupant load numbers and calculations on the cover sheet and egress plan are inconsistent II a. Sheet T -1 i. Occupancy calculations revised indicating occupant load calculations for each area matching egress plan spaces, Occupant load matches egress plan, sheet A - I.I ii. 2. "On the means of egress plan (A- I . I) a "demo room" on the occupancy schedule is indicated, however not shown.... ". a. Sheet A- I . I i. All rooms revised to match egress plan room names ii. Updated Sheet A -I as well iii. 3. "Note key #3 on Sheets A -4 and A -4.I indicates Elevation A/A -I.1, that detail cannot be located...." a. Sheet A -4 i. Note referring to Elevation A/A- I . I deleted b. Sheet A -4. I i. Note referring to Elevation A/A- I . I deleted 1 7 2 5 w e s t l a k e avenue north suite 2 1 0 seattle, Washington 98109 206.838.5485 p 206.464.0700 f Page 2 September 29, 2009 to Keith L. Smith, AIA principal • 4. "The door #7 on the door schedule indicates a panic bar with alarm. The door #2 to the corridor is also a panic bar with alarm...." a. Sheet A-I i. All hardware is existing, only new lock at front entry doors and new lever handle and privacy lock on office door. Door #7 is an existing lever hadle passage, no alarm or panic bar, note revised. Door #2 hardware is a panic bar and alarm, existing, note revised. If you require any further information, please don't hesitate to phone me at (206) - 713 -4076. Regards, 1725 w e s t l a k e avenue north s u i t e 2 1 0 seattle, Washington 98109 206.838.5485 p 206.464.0700 f Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 / U2 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 Water closet, tank or valve, >1.6 GPF 8 4 IA King County Department of Natural Resources and Parks Wastewater Treatment Division Subdivision Name Subdiv. # Building Name (ii a :cable umber (with Area Code P per C ntact Phone Mbar (With Are CQde) ` Owner's Mailing Address 20 Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units CYc 7 i111-19A 44 toc0 Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type Lot # �/ Bo , k# V A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total Fixture Units Y RCE For King County Lnly Account # No. of RCEs Monthly Rate Property Tax ID # Party to be Billed (if different from owner) City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre - existing building on this property. Credit for a demolition may be given under some circumstances. Demolition of pre- existing building? ❑ Yes' No Was building on Sanitary Sewer? Ayes ❑ No Was Sewer connected before 2/1/90? es ❑ No Sewer disconnect date: 0 Type of building demolished? Request to apply demolition credit to multiple buildings? ❑ Yes ❑ No B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facili /Process: 4 ( A B Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) _ 187 C. Total Residential Customer Equivalents: (add A & B) RCE RCE ECEll `ldr ED SEP 10 2009 PERMIT CENTEF Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of correbte• •atai'far�determination of a revised capacity charge. Date 1 (OA Signature of Owner /Representative Print Name of Owner /Representative 1058 (Rev. 9/07) White - Kina County Yellow - Local Sewer Aaencv Pink - Sewer Customer . ®.=w 4 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 INS CO LSM0095895 08/25/2009 Until n Cancelled $1,000,000.0008 08/25/2009 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 OHIO CASBHO(10) INS CO 53052413 06/08/200906/08 /2010 $1,000,000.0008 /25/2009 Name Role Effective Date Expiration Date Lawson, Marcia Anne OWNER 08/25/2009 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L&tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company Express Construction Services 3604271581 851 S.E. Somers Dr. SHELTON WA 98584 MASON Individual UBI No. 601074382 Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 ACTIVE EXPRECS918N5 CONSTRUCTION CONTRACTOR 8/25/2009 8/25/2011 GENERAL UNUSED Business Owner Information Bond Information Insurance Information I • Page 1 of 1 https://fortress.wa.gov/lni/bbip/Detail.aspx 10/13/2009 & ' L . -� :. ti l H 0 ti sr P r a�f e s i I ri ELI TI Fe t I•u iol t i it a rli i No changes EVISI 9 es f e made to the s cope SEPARATE PERMIT of work without prior a T ukwila guildin approval of REQUIRED FOR: NOTE; Revisions will r 9 Division. 4...chanical Ilil and may include add o n e a new plan submittal Fran review fees, ctrical i s P SPAC bing �' Gas Piping 1000 City of Tukwila BUILDING DIVISION 7 7 PROJECT GENERAL NOTES PROJECT DATA PROJECT DIRECTORY LANDLORD NOTES DRAWING INDEX I. SEE APPROPRIATE DRAWINGS FOR GENERAL NOTES OF OTHER DISCIPLINES: STRUCTURAL, ELECTRICAL, MECHANICAL AND PLUMBING. 2. DO NOT SCALE DRAWINGS- USE DIMENSIONS ONLY. 3. DIMENSIONS WHERE SHOWN ARE NORMALLY GIVEN: A. TO COLUMN CENTER LINE B. TO FINISH FACE OF CMU GWB. 4. DIMENSIONS SHOWN ON LARGER SCALE DRAWINGS GOVERN. 5. FIELD VERIFY ALL EXISTING CONDITIONS. REVIEW EXISTING CONDITIONS PRIOR TO COMMENCING THE WORK, NOTIFY ARCHITECT OF UNEXPECTED CONDITIONS. 6. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB, UNLESS NOTED OTHERWISE. 7. "ALIGN" AS INDICATED ON THE DRAWING SHALL BE UNDERSTOOD TO MEAN TO ALIGN THE FINISH MATERIAL OF THE WALLS OR COLUMNS INDICATED. 8. ALL INTERIOR GYPSUM WALL BOARD IS 5/8 " TYPE X GWB ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. SEE NOTE FOR LOCATION OF WATER RESISTANT GWB. 9. PROVIDE WATER RESISTANT TYPE X GWB IN ALL TOILET ROOMS, WAREWASH AND WET AREAS. 10. ALL FINISH CEILING HEIGHTS SHALL BE CONFIRMED UNLESS NOTED OTHERWISE ON THE ROOM FINISH SCHEDULE. 11. PROVIDE FINISH WALL BEHIND ALL EQUIPMENT AND CASEWORK. 12. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION. 13. PROVIDE ONE TYPE 5E- 2A -106C FIRE EXTINGUISHER PER 3,000 SF AND NOT MORE THAN 75 FT OF TRAVEL DISTANCE. 14. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT NONRATED, PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATED PARTITIONS. 15. WHERE HVAC OR OTHER MECHANICAL ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. 16. ALL CHANGES IN PROJECT SCOPE DUE TO CONTRACTOR GENERATED ALTERNATES OR EXISTING FIELD CONDITIONS SHALL BE TRANSMITTED TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 17. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING AND INSTALLING OF OWNER FURNISHED ITEMS LISTED, UNO. 18. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. 19. MODIFY THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS. 20. SPRINKLER HEADS MOUNTED IN HARD (GWB) CEILINGS TO BE FULLY RECESSED WITH WHITE CAPS. 21. INSTALL ALL COMPONENTS OF FIRE RATED ASSEMBLIES PER RATING CRITERIA 22. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 23. FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS. 24. PROVIDE FINISH FLOOR UNDER ALL EQUIPMENT AND CASEWORK. ADDRESS: 426 SOUTHCENTER MALL TUKWILA, WA 98188 -2888 CONSTRUCTION TYPE EXISTING/ NEW CONSTRUCTION TYPE: TYPE II -B UNPROTECTED NONCOMBUSTIBLE OCCUPANCY GROUP PRIMARY OCCUPANCY: M-MERCHANTILE INCIDENTAL OCCUPANCY: GROUP S1 APPLICABLE CODES: 2006 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS 2006 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENTS 2006 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS 2006 NATIONAL ELECTRIC CODE WITH WASHINGTON STATE AMENDMENTS CHAPER 11 IBC AND OTHER INTERNATIONAL BUILDING CODE REQUIREMENTS FOR BARRIER- FREE DESIGN INCLUDING ICC /ANSI A117.1 - 2003 2006 WASHINGTON NON RESIDENTIAL ENERGY CODE 2006 NATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS ALL LOCAL ORDINANCES HAVING JURISDICTION NUMBER OF EMPLOYEES NA ARCHITECT: smith co. LLC 1725 westlake avenue n. suite 210 Seattle, WA 98109 t: 206.838.54850 f: 206.464.0700 PROJECT MANAGER: Keith Smith TENANT WESTFIELD CORPORATION COORDINATION TENANT COORDINATION - SOUTHCENTER 14TH FLOOR, 1161 WILSHIRE BLVD. LOS ANGELES, CA 90025 (310) 478 -4456 T (310) 575 -5991 F Josh Kimmel (310.893.4761 ( MALL WESTFIELD SOUTHCENTER MANAGEMENT 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2888 (206) 246 -0423 T 1. ILLUMINATED SIGNAGE SHOULD BE CONTROLLED BY TIME CLOCK, LIGHT LEAKS FROM CASEWORK NOT PERMITTED. LANDLORD MUST APPROVE, IN WRITING, ALL PROPOSED SIGNAGE PRIOR TO INSTALLATION. 2. ALL CABLING AND WIRES TO BE CONCEALED. AUDIO WILL NOT BE PERMITTED. 3. SNEEZE GUARDS TO BE BUTT JOINTED, FRAMELESS, NO VERTICAL SUPPORTS WITH SQUARE EDGE DETAIL /UV BONDING 4. ALL LIGHTING REQUIREMENT TO BE INSTALLED WITHIN FLOATING RETAIL. LIGHTING TO BE SURFACE MOUNTED TO COUNTER DURING FABRICATION. 5 . TENANT MUST INSTALL LANDLORD APPROVED LATEX - RUBBER WATERPROOFING MATERIAL UNDER THE FLOOR FINISH. THE MEMBRANE MUST LAP UP PERIMETER WALLS UNDERNEATH THE COVED BASE TO MIN. HT. OF 12 "AFF. AND UNDER THE COVED BASE OF THE DISPLAY CABINETRY INSIDE OF THE RETAIL SPACE. 6. ALL MECHANICAL & PLUMBING SYSTEMS AND EQUIPMENT SHALL BE INSTALLED, BRACED AND INSULATED IN ACCORDANCE WITH ALL LOCAL CODE REQUIREMENTS. TENANT SHALL MAKE ALL CONNECTIONS TO THE UTILITY SERVICES PROVIDED. 7. FOR FOOD COURT TENANTS, THE DOMESTIC WATER SERVICE SHALL BE 2 ". TENANTS WITH HIGH WATER USAGE SHALL PROVIDE AND INSTALL A DOMESTIC WATER SUB - METER. TENANTS SHALL PROVIDE AND INSTALL A REDUCED PRESSURE BACKFLOW PREVENTER ON THEIR WATER SERVICE. WATER PIPING SHALL BE TYPE 'L' HARD COPPER TUBE ABOVE GRADE AND TYPE 'K' SOFT COPPER TUBE BELOW GRADE. WATER HEATERS SHALL BE ELECTRIC. , g FOR FOOD RELATED TENANTS, GAS SERVICE IS AVAILABLE. TENANTS ARE REQUIRED TO INSTALL AN EARTHQUAKE VALVE. 9 . TENANT SHALL DESIGN AND INSTALL AN ELECTRICAL /TELEPHONE BASED ON THE FOLLOWING: A 277 / 488 VOLT , THREE- PHASE, FOUR WIRE, 60 CYCLE SYSTEM. CONDUIT PROVISIONS FOR FLOATING FOOD KIOSKS: 200A (208Y / 120V) -(2) 3" CONDUIT. ELECTRICAL SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH LANDLORDS CRITERIA AS OUTLINED IN THE DESIGN MANUAL. 10. TENANTS CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER. ARCHITECTURAL T -1 GENERAL INFORMATION D -1 DEMOLITION PLAN A -1 CONSTRUCTION PLAN A -1.1 FIXTURE /EGRESS PLAN A -2 FLOOR FINISH PLAN A -3 REFLECTED CEILING PLAN A -4 ENLARGED STOREFRONT ELEVATION /PLAN A -4.1 ENGLARGED EXISTING SECTIONS /DETAILS A -5 ENLARGED EXISTING TOILET PLAN /DETAILS ELECTRICAL E -1 ELECTRICAL POWER/LIGHTING PLANS E -2 ELECTRICAL PANEL SCHEDULES E -3 ELECTRICAL SPECIFICATIONS MECHANICAL NO CHANGES TO MECHANICAL PLUMBING P -1 PLUMBING PLAN NOTES AND SCHEDULES SHEET A -1.1 foot-candle at the walking surface leading to the exit discharge doorways JJJ SITE PLAN VICINITY MAP MEANS OF EGRESS V e ANCY GROSS FLOOR FLOOR AREA OCCUPANT I i i / ii FUTURE RETAIL l l - -__ z,,,, �! IV _h AREA OCCUPANT LOAD S ALES AREA 709 S.F. 30 S.F. 23 OFFICE 37 S.F. 100 S.F. 1 DEMO ROOM 141 S.F. 30 S.F. 5 SUITE 1 93 S.F. 30 S.F. 3 SUITE 2 92 S.F. 30 S.F. 3 SUITE 3 93 S.F. 30 S.F. 3 CONSULTATION ROOM 70 S.F. 30 S.F. 3 BREAKROOM 100 S.F. 300 S.F 1 SEPARATE SUBMITTALS N ORDSTROM f i r ms ��� macy§ I� 0 ° ❑ f btu ❑ o O ❑ o o FIRE ALARM AND SIGNAGE UNDER SEPARATE SUBMITTAL. 0 0 0 • a �� •��� ��^ ' \° ❑ ___. , LOCATION J 7-- i Space 1000 I SCOPE O F WORK ❑ -' 11_ I (, Pt � , T T N ' . J ' -.: SOUTHCENTER PKY BUILDING: THE WORK INCLUDES, BUT NOT LIMITED TO INTERIOR TENANT IMPROV. AND FINISHES, ITEMS FURNISHED BY THE OWNER AND INSTALLED BY CONTRACTOR AND ITEMS FURNISHED AND INSTALLED BY THE OWNER CONNECTIONS BY THE CONTRACTOR. THE WORK ALSO INCLUDES, BUT NOT LIMITED TO, INTERIOR AND STOR SIGNAGE, HVAC SYSTEMS, ENERGY MANAGEMENT SYSTEMS, PLUMBING ELECTRICAULIGHTING SYSTEMS. ON SITE: NO WORK ENTS HE WITH FRONT ND FINAL stun TOT OCCUPANCY LOAD: 1,333 S.F. 42 _ 111 �' lip \\ I 0 D�• _ REQUIRED PROVIDED WIDTH: (42 OCCUPANTS x 0.2 IN.) = 8.4 IN. 108" OF EXITS: 2 2 M AXIMUM TRAVEL TO EXITS: 250 FT. (SPRINKLED) f40' -0" I•'"" © _'�� =1 = j _ J - -_ _ r �•• - _ _ - _ - , ilk II. SCALE: N.T.S. FOR ADDITIONAL ABBREVIATIONS ARCHITECTURAL ABBREVIATIONS SEE OTHER DESIGN DISCIPLINES ARCHITECTURAL SYMBOLS ACOUS. ACOUSTICAL ELEV. ELEVATION L. LONG, LENGTH PR. PAIR T.O.S. • - e TEEL SYMBOLS NORTH ARROW (- - - - - - 1 PROJECT NORTH I I ITEM S.I.O MATERIALS REVISION CLOUD OR N.I.C. i` DETAIL DETAIL IDENTIFICATION CUT LINE - DEFINES THE DETAILED ELEMENT A8.01 SHEET WHERE DRAWN WALL SECTION DETAIL IDENTIFICATION CUT LINE - DEFINES THE DETAILED ELEMENT A7.01 �� SHEET WHERE DRAWN BUILDING SECTION DETAIL IDENTIFICATION 6 A 3.01 SHEET WHERE DRAWN EXTERIOR ELEVATION DETAIL IDENTIFICATION 8 ADJ ADJUSTABLE, ADJACENT ELEC. ELECTRICAL LAM. LAMINATE, LAMINATED PROJ. PROJECT T.O.W. TOP OF WALL A.F.F. ABOVE FINISHED FLOOR (SLAB) ENCL. ENCLOSURE L.F. LINEAR FOOT, LINEAL FOOT PRV PRESSURE REDUCING VALVE T &B TOP AND BOTTOM ALUM ALUMINUM EQ. EQUAL LIQ. LIQUID P.T. PRESSURE TREATED TEL. TELEPHONE ANOD. ANODIZED EXH. EXHAUST L.P. LOW POINT Q.T. QUARRY TILE TEMP. TEMPERED GLASS APPROX. APPROXIMATE EXIST. EXISTING LT.WT. LIGHT WEIGHT QTR. QUARTER TYP. TYPICAL BD. BOARD EXP. EXPANSION MAS. MASONRY R RADIUS UTIL. UTILITY B.F.F. BELOW FINISHED FLOOR (SLAB) EXT. EXTERIOR MAX. MAXIMUM R.C. REFRIGERATION CONTRACTOR U.B.C. UNIFORM BUILDING CODE BLDG. BUILDING F.D. FLOOR DRAIN M.B.S. METAL BUILDING SUPPLIER R.C.P. REFLECTED CEILING PLAN U.N.O. UNLESS NOTED OTHERWISE BLK. BLOCK FDN. FOUNDATION MECH. MECHANICAL R.D. ROOF DRAIN V.C.T. VINYL COMPOSITION TILE BLK'G. BLOCKING FF FACTORY FINISH MFG. MANUFACTURING R.L. ROOF LEADER VERT. VERTICAL BM. BEAM FHS FLAT HEAD SCREW MFR. MANUFACTURER REC'D. RECEIVED V.I.F. VERIFY IN FIELD BOT. BOTTOM FL. FLOOR M.H. MANHOLE REFRIG. REFRIGERATION W/ WITH MINN. BETWEEN F.I.O. FURNISHED AND INSTALLED MIN. MINIMUM REINF. REINFORCING W/O WITHOUT CB CATCH BASIN BY OWNER M.I.P. METAL INSULATTED PANEL REQ'D. REQUIRED WD. WOOD C.G. CORNER GUARD FIN. FINISH MISC. MISCELLANEOUS R.O. ROUGH OPENING WDW. WINDOW C.I. CAST IRON F.R.P.P. FIBER REINFORCED PLASTIC M.O. MASONRY OPENING SCHED. SCHEDULE WHS. WELDED HEAD STUD C.I.P. CAST IN PLACE PANEL(S) M.R. MOISTURE RESISTANT S.C. SOLID CORE W.P. WATERPROOF C.L. CENTER LINE FRT. FIRE RETARDANT TREATED MULL. MULLION SHT. SHEET W.R. WATER RESISTANT CLR. CLEAR FTG. FOOTING MTD. MOUNTED SIM. SIMILAR WT. WEIGHT CLG. CEILING GA. GAUGE MTG. MOUNTING S.I.O. SUPPLIED AND INSTALLED W.W.F. WELDED WIRE FABRIC CMU CONCRETE MASONRY UNIT GALV. GALVANIZED MTL. METAL BY OWNER Y.D. YARD DRAIN COL. COLUMN G.C. GENERAL CONTRACTOR N.I.C. NOT IN CONTRACT S.I.V. SUPPLIED AND INSTALLED CONC. CONCRETE GWB GYPSUM WALLBOARD, GYPSUM NOM. NOMINAL BY VENDOR CONT. CONTINUOUS BOARD N.T.S. NOT TO SCALE S.O.I.C. SUPPLIED BY OWNER INSTALLED CONSTR. CONSTRUCTION H.B. HOSE BIBB O.A. OVERALL BY CONTRACTOR CONTR. CONTRACTOR H.C. HANDICAPPED O.C. ON CENTER SQ. SQUARE C.T. CERAMIC TILE H.M. HOLLOW METAL O.D. OVERFLOW DRAIN S.S. SERVICE SINK, SANITARY SEWER DBL DOUBLE HORIZ. HORIZONTAL O.H. OVERHEAD SST STAINLESS STEEL DIM. DIMENSION H.P. HIGH POINT OP'G OPENING STD. STANDARD DTL. DETAIL HT. HEIGHT OPP. OPPOSITE STL. STEEL D.F. DRINKING FOUNTAIN HTR. HEATER PTN. PARTITION STRUCT. STRUCTURE, STRUCTURAL D.S. DOWNSPOUT HVAC HEATING, VENTILATION, AND PERP. PERPENDICULAR SUSP. SUSPENDED DWG. DRAWING AIR CONDITIONING PL. PLATE, PROPERTY LINE SYS. SYSTEM - EA. EACH IBC INTERNATIONAL BUILDING CODE PLAS.LAM. PLASTIC LAMINATE T TREAD, TOP E.F.S. EXTERIOR FINISH SYSTEM INSUL. INSULATION PLYWD. PLYWOOD T.O.J. TOP OF JOIST E.I.F.S. EXTERIOR INSULATION AND INT. INTERIOR PLBG. PLUMBING T.O.M. TOP OF MASONRY FINISH SYSTEM JT. /JTS. JOINT, JOINTS PNL. PANEL, PANELING T.O.P. TOP OF PARAPET , ARROW � � - - - - J ►` AND DELTA AIIII GYPSUM BOARD TRUE NORTH ` INDICATOR DOOR MARK 50' - 0" A.F.F. WORK, CONTROL ITEM S.O.I.0 OR S.I.C. . ..`: CONCRETE EARTH GRAVEL CMU OR BRICK PLYWOOD RIGID INSULATION BATT INSULATION WOOD MEMBER ' - 1 11 ��, ...�, OR DATUM POINT DOOR CODE - TO 2580A SCHEDULE SLOPE DIRECTION SLOPE DOWN WITH DATUM MARK NEW CONSTRUCTION - SHOWN SOLID r A WINDOW, RECITE OR 1/8" PER FOOT LOUVER MARK � - - ' ?;; WINDOW SPRINKLER MAIN NUMBER - REFER / NW TO SCHEDULE / E QUIPMENT MARK EXISTING CONSTRUCTION TO REMAIN PROPERTY LINE - SHOWN LIGHT BACKGROUND _/ WOOD BLOCKING EQUIPMENT .. 0 N UMBER - REFER TO SCHEDULE FENCE x .0 J(� FINISHED WOOD III III ih ACOUSTICAL TILE �� / STEEL x x x x x x x ROOM MARK ROOM -- ROOM NAME EXISTING CONSTRUCTION TO BE M ALUMINUM BREAKLINE A3.02 S HEET WHERE DRAWN 1 00 ROOM NUMBER REMOVED - SHOWN DASHED g E.I.F.S. - - INTERIOR ELEVATION 0 COLUMN GRIDS WALL TYPE MARK DETAIL IDENTIFICATION SOUND INSULATION 5.03 6 WALL TYPE O FE FIRE EXTINGUISHER SHEET WHERE DRAWN B X 7 NOTE l BRI E - 7- SMILE ,x1 , One Hour P r a'fes. iib real Teeth Whitening 426 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant FILE C y Permit No. tOF I Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize t violation of any adopted code or ordinance. Receipt of approved F" Copy d conditions is acknowledged: By Date: Consultant Registration EVIEWED FOR CO DE COMPLIANCE APPROVED OCT 0 9 2009 4 WIC City of Tukwila BUILDING DIVIRIflM Issues and Revisions No. Date 1 09.09.09 2 09.29.09 City Of lbkwila BUILDING DIVISION 6294 RECEIVED CITY OF TUKWILA CORRECTION Project Name BRITE SMILE Project Number 02006088.00 Description GENERAL INFORMATION Computer File CW05- 2009- T1.DWG Scale AS NOTED Template 4.3 (120101) T - Architect Registration REGISTERED ARCHITECT ' KEITH L. SMITH STATE OF WASHINGTON Issues By Check PERMIT KLS PERMIT CORRECTIONS KLS SEP 3 0 2009 PERMIT CENTER All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. llc. MALL COMMON 00 —ICU o 1 0 (Y) Cu ICU 0 00 L . L TEL /DATA r -J a 5 ,_ 7 1„ 12' -10 REMOVE EXISTING FLOOR FINISHES I� i RESTROOM 1 104 STOCKROOM 104" I103I DEMOLITION PLAN SCALE: 1/4" =1' -0" i /— 9' -104" — - J 10' -9 REMOVE EXISTING FLOOR FINISHES REMOVE EXISTING FLOOR FINISHES REMOVE EXISTING COUNTERS „ III REMOVE EXISTING FLOOR FINISHES REMOVE EXISTING DRINKING FOUNTAIN REMOVE EXISTING FLOO FINISHES 10' -92" 62' -62" REMOVE EXISTING FLOOR FINISHES 35' -7" ADJACENT TENANT 1 696 ADJACENT TENANT 10051 13' -9 r „ -,,- - —1{1 II II II II REMOVE EXISTING CASEWORK FOR NEW CASEWORK REMOVE EXISTING FLOOR FINISHES SALES AREA 101 14' -4” ,_ OD MALL COMMON 100 I �. B RIT.E.M ..I . Onto Haaur Prof gssir real Tt ties tii1 nia1 &] 426 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2009 City of Tukwila BUILDING DIVIRION Issues and Revisions No. Date 1 09.09.09 2 09.29.09 Project Name BRITE SMILE Project Number 02008018.00 Scale AS NOTED Template 4.3 (120101) D -1 6294 Description DEM❑LITI ❑N PLAN Computer File CW05 2009— D1,DWG Architect Registration REGISTERED ARCHITECT ' KEITH L. SMITH STATE OF WASHINGTON Issues By Check PERMIT KLS PERMIT CORRECTIONS KLS CITY OF TUKW1 A SR) S 0 2009 All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. __ 1 . N I S H LEGEND ® SEE RESPONSABILITY SCHEDULE ON Ti. NO \ F -- \ \ 1 N up Y, FRAME MATERIAL __ J OOR SCHEDULE SEE RESPONSABILITY SCHEDULE ON T1. . N I S H LEGEND ® SEE RESPONSABILITY SCHEDULE ON Ti. NO ROOM NAME DOOR SIZE DOOR MATERIAL DOOR FINISH FRAME MATERIAL FRAME FINISH HARDWARE GROUP NOTES NO. MATERIAL MANUFACTURER SPECIFICATIONS P -1 I PAINT BENJAMIN MOORE T.B.D. O EXISTING FRONT ENTRY 6' -0" X 8' -0" ALUM /GLASS GLASS ALUM. ANOD. ALUM. OA P -2 PAINT BENJAMIN MOORE T.B.D. P— . PAINT BENJAMIN MOORE T.B.D. O EXISTING REAR EXIT EXISTING HARDWARE 3' -0" X 7' -0" METAL CP -2) METAL CP -2) © P -4 PAINT BENJAMIN MOORE T.B.D. F -1 LAMINATE FLOORING T.B.D. NEW LAMINATE FLOORING O3 EXISTING EXISTING HARDWARE TOILET 3, X 7,-0„ WOOD P -2 METAL P -2 F -2 SEALED CONCRETE BY GC F -3 CERAMIC TILE DAL TILE EXISTING O EXISTING EXISTING HARDWARE DOORS 3' -0" X 7' -0" WOOD CP -2) METAL F -4 VINYL COMPOSITE TILE ARMSTRONG EXISTING ( ) F -5 ALL TILE MALL TILE EXISTING O5 EXISTING TEL /DATA EXISTING HARDWARE „ 3'-0” X 7'-0" WOOD P 72 METAL P -2 F -6 :XISTING TO REMAIN B -1 COVE BASE JOHNSONITE T.B.D. O NEW OFFICE DOOR 3' -0" X 7' -0" WOOD P -2 METAL P-2 © 1, 2, 5, 6, B -2 6" VINYL COVE BASE ARMSTRONG T.B.D. B -3 1 6" TILE BASE DAL TILE T.B.D. CD EXISTING EXIT CORRIDOR EXISTING HARDWARE 3' —O" X 7' -0" WOOD ( METAL �P -2) Op CL— GYP. BD. CEILING EXISTING PAINTED GYP. BD. L -2 SUSPENDED ACT EXISTING DOOR HARDWARE C -1 FRP PANELS STRUCTOGLAS EXISTING NTERIOR FINISH MATERIALS SHALL BE CLASS A OR CLASS B PER NFPA 101, 24 -3.3 OA ENTRY PUSH /PULL HARDWARE W/ NEW LOCKSET, CLOSER DOOR NOTES ® PRIVACY LEVER HARDWARE (BRUSHED CHROME) — EXISTING HARDWARE TO REMAIN IF DOOR IS EXISTING 1. NEW DOOR SUPPLIED, INSTALLED AND FINISHED BY G.C. . 2. ALL NEW DOOR OPENINGS ARE NONBEARING OR NON —SHEAR WALLS. 3. EXISTING SERVICE DOOR BUZZER WITH BUZZER STATIONS ABOVE CEILING AT CASHWRAP AND OFFICE. 4. EXIT DOORS SHALL NOT BE SUBJECT TO THE USE OF A KEY OR REQUIRE SPECIAL KNOWLEDGE TO OPERATE PER 2006 IBC 5. INSTALL WALL DOOR STOPS AT HEIGHT OF DOOR KNOB AT ALL DOORS THAT SWING INTO OR OUT TOWARD A WALL. 6. INSTALL DOOR SILENCERS. 7. NOT USED 8. SALES TO CORRIDOR DOOR TO HAVE A DORMA DOOR CLOSER WITH MODEL #DC —DSTHO "HOLD OPEN ARM" 9. EXISTING WIDE ANGEL PEEP HOLE. ANY DOOR NOT CONFORMING TO THIS PLAN OR CODE SHALL BE UPGRADED AS REQUIRED PER ALL CODES. SWING AND FORCE TO OPEN DOORS SHALL MEET THE REQUIREMENTS OF THE IBC 2006 SELF CLOSING DEVICES SHALL MEET THE REQUIREMENTS OF THE IBC 2006 PANIC HARDWARE SHALL BE PROVIDED FOR ALL EXIT DOORS PER THE REQUIREMENTS OF IBC 2006 © PANIC BAR HARDWARE WITH ALARM AND CLOSER (EXISTING HARDWARE TO REMAIN) OD PASSAGE HARDWARE, ADA LEVER HANDLE, BRUSHED CHROME, EXISTING HARDWARE TO REMAIN GENERAL NOTES 1. T.G.C. TO a t• • WINDOWS WITH • IN PAPER UN I HE END OF CONSTRUC N. W OWS MUST THEN BE CLEANED AFTER R ,, eVAL AND A :• I1 SIVE ' 1 I '.PER c :E REMOVED A WINDOWS TO BE CLEANED PRIOR TO TURNOVER 2. T.G.C. TO VERIFY DOORS IN THE MEANS OF EGRESS SYSTEM TO BE OPERABLE FROM INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 3. INTERIOR WALL AND CEILING FINISH MATERIALS IN MERCANTILE OCCUPANCIES SHALL BE CLASS A OR CLASS B PER NFPA 101, 24 -3.3 4. T.G.C. SHALL PROVIDE SUFFICIENT NUMBER OF 2A1OBC FIRE EXTINGUISHERS SO THAT A FIRE EXTINGUISHER CAN BE REACHED WITHIN 75 FEET OF NORMAL TRAVEL FROM ANY POINT IN THE BUILDING. PLEASE TAKE INTO CONSIDERATION THAT FIRE EXTINGUISHERS SHOULD BE LOCATED NEAR EXITS. MOUNTING HEIGHT SHALL BE 4 FEET A.F.F. MAXIMUM. 1/2" TEMPERED GLASS TOP 1 1/2"x1 1/2"x1/8" CONT. ALUMINUM ANGLE TO SUPPORT BACK EDGE OF REMOVABLE PANEL (FASTEN TO SOLID WOOD CLEAT W/ FLATHEAD SCREWS © 4" O.C.) HANDICAP ACCESSIBLE LIFT UP WRITING SURFACE. SWING AWAY SHELF SUPPORT HANDICAP LIFT —UP WRITING SURFACE THIS END ONLY. I ETTAIMPTJAIVAINMMAI I Id '-IN CD 0 cV 4 1 » 2 3- 3- 4 1/2" DIA. R BOTTOM COR OF HOLE —PU NO BLOCKIN HOLE. SECTION AT ADA LIFTUP SCALE: 1/2' SIDE ELEVATION SCALE: 1/2' -1' -0' DIUS ERS L TYP. BEHIND HANDICAP LIFT —UP WRITING SURFACE THIS END ONLY. CO 0 N MALL COMMON I 00 I Co CO 1/2" TEMPERED GLASS TOP WRITING SURFACE ' / 1' -0" / 1-6" FLIP UP ADA COUNTER @ 34" AFF 2' -6" a NEW COUNTER"? 0 0 CHECKOUT COUNTER SCALE: 1/2' - 1' -0' FRONT ELEVATION SCALE: 1/2' EXISTI DOOR L - , r -J I I I EXISTING SUITE 3 TEL /DATA EXISTING OFF FLIP UP ADA COUNTER @ 34' AFF NEW COUNTER NEW COUNTER SALES AREA EXISTING SUITE 2 1031 EXISTING SUITE 1 EXISTG CONSULTATION R EXISTG DEMO RM GREAR EXIT EXISTING DEMI WALL EXISTING BREAKROOM 35' -7" 14' -4" 0 0 7' -6" 0 1 5' -0" 0 EXISTING ELECTRICAL PANEL AND PHNE BOARD 1/2" TEMPERED GLASS TOP WRITING SURFACE WHITE PLAM. FLOOR PLAN SCALE: 1/4" = 1' -0" ' -10 4 ADJACENT TENANT 696 1 62' -62" ADJACENT TENANT 11005 P ONT TO NEW SIGN UNDER SEPARATE PERMIT MALL COMMON 1001 112. One Hour Pr afn rola;I Teeth 'Whitening 426 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2009 City of Tukwila BUILDING DIVISION Issues and Revisions No. Date liE 1 09.09.09 2 09.29.09 Project Name BRITE SMILE Project Number 02008018.00 Description FLOOR PLAN Template 4.3 (120101) A -1 Scale AS NOTED SMILE' 6294 Computer File CW05- 2009— A1,DWG Architect Registration REGISTERED ARCHITECT ( KEITH L. SMITH STATE OF WASHINGTON Issues By Check PERMIT KLS PERMIT CORRECTIONS KLS CITY OF TUKWILA SPP 3 0 ?Q09 PERMIT CENTER All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. MEANS OF EGRESS: OCCUPANCY SALES AREA OFFICE DEMO ROOM SUITE 1 SUITE 2 SUITE 3 CONSULTATION BREAKROOM GROSS FLOOR FLOOR AREA AREA OCCUPANT 709 S.F. 30 S.F. 37 S.F. 100 S.F. 141 S.F. 30 S.F. 93 S.F. 30 S.F. 92 S.F. 30 S.F. 93 S.F. 30 S.F. ROOM 70 S.F. 30 S.F. 100 S.F. 300 S.F. TOTAL OCCUPANCY LOAD: 1,333 S.F. EXIT WIDTH: # OF EXITS: MAXIMUM TRAVEL DISTANCE TO EXITS: REQUIRED (42 OCCUPANTS x 0.2 IN.) = 8.4 IN. 2 250 FT. (SPRINKLED) ±4C-0" OCCUPANT LOAD 23 1 5 3 3 3 3 1 42 PROVIDED 108" 2 62' -62" TEL /DATA G�� 4 . 0 0 SUITE 101 Aso4, —�\ RESTROOM 104 4 10' ■ BREAKROOM 1 103 9' -10 OFFICE 103 SUITE 2 101 SUITE 1 CONSULT. RM. 103 01 \ I; r • DEMO ROOM 101 35' -7" FLI ADA P UP COUNTER @ 34' AFT a * SAL s• rl r' 1 L - -Ji j r - -1 I LJ LJ GO a 5 ,_ 7 1„ 12' - 10 1' -104" EGRESS PLAN SCALE: 1/4 =1' -On 10' -9 // 10' -92" ADJACENT TENANT 1 ADJACENT TENANT 1 696 13' -9 14' -4" L COMMON 00 I B li iTE One Healy P r ifa siir real Teeth Whtiih:e rding 426 Southcenter Mall Tukwila, WA 98188 smith e*. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http://www.smithco.org/ Consultant Consultant Registration REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2009 City of Tukwila BUILDING DIVISII7N Issues and Revisions No. Date 1 09.09.09 2 09.29.09 Scale Template Project Name BRITE SMILE Project Number 02008018.00 Description FIXTURE PLAN AS NOTED 4.3 (120101) A -1 6294 Architect Registration REGISTERED ARCHITECT KEITH L. SMITH (STATE OF WASHINGTON Issues By Check PERv1IT KLS PERMIT CORRECTIONS KLS Computer File CW05- 2009 — A1-1,DWG CITY OF TUKWILA SEP 0 ?U09 PERMIT CENTER All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. TEL /DATA L -, r -J r -J L - i 4„ 12' -10 „ ' -1 0 3„ 4 i V F -4 SCALE: 1/4! = 1' -0� FINISH PLAN 10' -9 10' -92" Ak 62' -62" 35' -7" 13' -94" PP/r Li I �r� LJ CONTRACTOR'S NOTE WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. DO NOT SCALE DRAWINGS. CONTRACTOR'S MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF WORK, TO TENANT REPRESENTATIVE. REPORT DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED FOR JOB OR CODE COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION. 14' -4" / — co ITE -SINALILE 0®i. Ploy Professional Teutla 1 426 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2009 City of Tukwila BUILDING DIVISION Issues and Revisions No. Date 09.09.09 Project Name BRITE SMILE Project Number 02008018,00 Description FLOOR P L A N Computer File CW05 2009— A2,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. lic. A -2 6294 Architect Registration REGISTERED ARCHITECT -- c L SMITH ( STATE OF WASHINGTON Issues By Check PERMIT KLS R OF TuUR CITY LA SEP S 0 2009 PERMIT CENTER PLAN KEY CL4 CL4 ti1 g Li / (3)FBO31/ 835 120V 14' -4" \ / C2 2'x2'x3/4" Beveled Tegular C4 White C2 M■A DPS2G18L P340 D3 C4 C B C 2' 6 I „o -,9 Q C OC 50W PAR 30 NSP /H -C 120V Sales Area C . DD3 Cl.< 8'- 0 "/4'- 0 "/2' -0" Surface Mounted Track N BY IKACK LILHI OWNER 3Y OW Sales Area , CL4 CL4 2'x4'x5/8" 4'- 0 "/2' -0" Recessed Cove Lighting PLAN KEY CSI SECTION 2'x2' Recessed Fluorescent, w Parabolic Troffer g Li / (3)FBO31/ 835 120V Sales Area \ / C2 2'x2'x3/4" Beveled Tegular Armstrong C4 White 2'x4' Recessed Fluorescent, w/ Parabolic Troffer M■A DPS2G18L P340 D3 Office, Exam Rooms C B C 2' 6 Track Head Light Lightolier 9021 -WH, 50W PAR 30 NSP /H -C 120V Sales Area 8'- 0 "/4'- 0 "/2' -0" Surface Mounted Track N BY IKACK LILHI OWNER PLAN KEY CSI SECTION 2'x2' Recessed Fluorescent, w Parabolic Troffer g Li DPA2G9LP 32U12003 (3)FBO31/ 835 120V Sales Area \ / A 2'x2'x3/4" Beveled Tegular Armstrong 589 Cirrus White 2'x4' Recessed Fluorescent, w/ Parabolic Troffer Lightolier DPS2G18L P340 3 -T8 120V Office, Exam Rooms B C 09510 Track Head Light Lightolier 9021 -WH, 50W PAR 30 NSP /H -C 120V Sales Area 8'- 0 "/4'- 0 "/2' -0" Surface Mounted Track Lightolier 6002/6001/ 6000 WHITE Sales Area I C2 /C4 /C8 09510 2'x4'x5/8" 4'- 0 "/2' -0" Recessed Cove Lighting Lightolier CL12 CL14 T8 120V Demo Room With Lutron Eco -10 Series Dimmable Ballasts I I CL4 I CL2 D O Minaboard Recessed Compact Fluorescent Down Light Lightolier 8021CCDW - 6132BU- 1951 PLT /32/4P/ /D830 Sales Area D1 O Recessed Downlight - Specular Clear Lightolier 11041C- 1144 75W PAR 30S /CAP NFL 120V Restaurant Room D2 Recessed Adjustable Dn. Light Lightolier 1102P1- 1129CL 60W PAR38 Cap /FL 120V Sales Area, Cashwrap, Restaurant Room D3 >0 Prelude Track Head Light w/ Monopoint Lightolier 9023 -WH, 6190 -WH 50W PAR 30 NSP /H -C 120V Sales Area Exposed Tee \ C / 09250 Ceiling Soffit ED EM Recessed Emergency Light with 90 Minute Battery Backup DUAL -LITE EZ -2R 120 Volts 8W Sales Area F Surface Mounted 2' Fluorescent Strip Lightolier SW220TS HPF 2 -20TS 120V Tel /Data Closet 1 F11 Surface Mounted 4' Fluorescent Strip Lightolier SW24ORS HPF 2 -4ORS 120V Breakroom 1 G E Pair of Cabinet Light Fixture Kichler 10566 WH Series I 22" Long (3) 12V Xenon Sales Area Interactive Displc Centered Vertically and Hori in Rear Wall of Alcove Install w /Lens Side Up H1 Wall Sconce Kichler 6966BK 100W 120V Restaurant Room Center on wall at 7' -0" A.F to bottom OK Pendant Mounted Fixture Kichler 2768N1 4 -60W 120V Demo Room Centered on Ceiling Grid 7' -6" A.F.F. to bottom of f K2 O Pendant Mounted Fixture Kichler 3030N1 100W 120V Cashwrap 7' -6" A.F.F. to bottom of f Mono -Point Incandescent Wall Washer Lightolier 6422 -WH Q150CL DC -ETC 120V Soffit at Sales Area N I Combination Fan/ Light NUTONE 8663P 120 Volts 1 -100W Toilet Room T (2) Head Emergency Light Astralite EU -1 INC Breakroom, Demo Room U V LED Exit Sign Astralite TP -U -R- W -EM INC Ceiling mounted Sales Area, Breakroom Designates Night -light 8'- 0 "/4'- 0 "/2' -0" Surface Mounted Track Lightolier 6002/6001/ 6000 WHITE I I C2 /C4 /C8 O Pendant Light by Owner Ceiling Mounted Sales Area PLAN KEY CSI SECTION MATERIAL/ DESCRIPTION MFR. STYLE/ CAT. NO. COLOR LOCATION \ / 09510 2'x2'x3/4" Beveled Tegular Armstrong 589 Cirrus White Sales Area, Exam Rooms Lay -in Tile \u/ 09510 2'x2' Ceiling Grid Armstrong 9/16" Suprafine White Sales Area, Exam Rooms Exposed Tee 09510 2'x4'x5/8" Armstrong 755 White Break Room Fissured Lay -in Minaboard Ceiling Tile 09510 2'x4' Ceiling Grid Armstrong 15/16" White Break Room Prelude Exposed Tee \ C / 09250 Ceiling Soffit Sales Area 5/8" F.C. GWB C B Light Fixture Schedule / 16000 - LIGHTING SYMBOL QUANTITY DESCRIPTION DESCRIPTION MFR. STYLE/ VOLTS/ CAT. NO. LAMPS COMMENTS (existing notes and ceiling finishes) NOTE 1: TENANT LIGHT FIXTURE VENDOR IS RESPONSIBLE FOR VERIFYING THE QUANTITIES ON THE LIGHT FIXTURE SCHEDULE WITH THE REFLECTED CEILING PLAN. LIGHT FIXTURES ARE TO BE FURNISHED BY TENANT AND INSTALLED BY T.G.C. l y, zantally ixture ixture TEL /DATA CLOSET OPEN TO DECK OFFICE FINISHED CEILING HEIGHT • 9' -0" .F.F. • TOI LEL -R_OQ Vi GYP. BD. CEILING • 7' -6" A.F.F. • WITH PLATFORM ABOVE NOTE: BREAK ROOM CEILING CONTINUES ABOVE TOILET ROOM. S EGRESS CORRIDOR FINISHED CEILING HEIGHT 8' -6" A.F.F. -J V V ID r =J L-, r L- D a • •iim Fl *0 0* 00 GEM FINISHED CEILING HEIGHT 11' -6" A.F.F. FINISHED CEILING HEIGHT 8' -6" A.F.F. FINISHED CEILING HEIGHT 10' -0" A.F.F. I I T N Fl SCALE: 1/4" =1' -Y C2 \ S S 2' 6" D3 >0 Fl FINISHED CEILING HEIG T Fl C4 C (DEM 3 REFLECTED CEILING PLAN B O2 VOID D3 10' -0" A.F.F. 9' -10" A.F.F. 2'- 6" FINISHED CEILING HEIGHT SOFFIT 1 FINISHED CEILING HEIGHT 11' -10 3/4" A.F.F. FINISHED CEILING HEIGHT D2 O 3' -0., C> 16. S S D3 C D3 -S O C4 C2 N /c) Key to Reflected Ceiling 09000 - FINISHES CEILING A \D SOFFIT FINISHES GEM 02 0 NOTE 1: CEILING TO HAVE CLASS A FLAME SPREAD RATING. N K2 02Q 0 0* 47 D 2' -0 K O VOID D2 SOFFI FINISHED FEILING HEIGHT 9' -10" A 10' -0" A.F.F. LJ NOTE 2: RABBET EDGES 1/8" LOWER THAN GRID TO PERMIT PERIMETER TILES TO _IE FLUSH WITH FIELD. INSTALL HOLD DOWN CLIPS ON ALL TILES WITHIN 20' -0" OF ENTRANCE. FINISHED CEILING HEIGHT r' 1 - -Ji �,� ._' L � r - L lJ VOID P• D1O A /I ° x711 _D1 L _ UI 1 • D3 LJ 6' -0" D2 (existing notes and ceiling finishes) 4' -0" D3 VOID EM S D SOFFIT FINISHED CEILING HEIGHT 8' -0" A.F.F. II LIl VD3 n NEW PENDANT LIGHT BY OWNER 11 NEW SIGN UNDER SEPARATE PERMIT SOFFIT FINISHED CEILING HEIGHT 9' -10" A.F.F. SOFFIT FINISHED CEILING HEIGHT 10' -0" A.F.F. 11' -4" A.F.F. 4 j1 SALES AREA FINISHED CEILING HEIGHT 6 lei FLIE T - M ! One Hour P r of e si nai Whitt .`rmisij 426 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2009 City of Tukwila BUILDING DIVISION °"`°tssues'and ' No. Date 1 09.09.09 PERMIT KLS Project Name BRITE SMILE Project Number 02008018.00 Computer File CW05 2009— A3,DWG Scale AS NOTED Template 4.3 (120101) A -3 6294 Architect Registration REGISTERED ARCHITECT KEITH L. SMITH (STATE OF WASHINGTON Issues By Check RECEIVED CITY OF TUKI ILA PERMIT CENTER Description REFLECTED CEILING PLAN All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. . ) Note Key (Notes for existing conditions) — 0 5/8" Fire Code Sheetrock g 1/2" Fire Retardant M.D.F. Board 0 .040 Break M ® 3 5/8" Metal Stud 5 Suspended Gypsum Board Ceiling System With Hang Wire ® 4'-0" O.C. Each Way Suspend From Structure Above © Existing Framing 0 Existing Gypsum Board ® 1/2" Tempered Glazing – 1/8" Air Space At Vertical Joints – No Silicone Typ. 0 6" High x 2" Wide Glazing Channel with Anchor. 10 1 3/4" High x 2" Wide Glazing Channel. 11 12 Reserved 13 Reserved 14 Wood Blocking (Fire Retardant) 15 Neoprene Gasket 16 Reserved 17 3 5/8" Metal Track 18 Glazing Vinyl, Inside and Outside 24 © 3 4" x 3 4" x 1 8 Black Metal U– Channel • Down Light beyond © Existing Landlord Neutral Pier & finish to remain. 0 Storefront Sign Furnished and Installed by Tenant's Sign Contractor (3 6" High x 3/4" wide Metal Trim. Ga. Minimum at MALL BULK HEAD 3/4 "x3/4" BLACK METAL U- CHANNEL REVEAL TOP AND SIDES OF STOREFRONT 1 3/4" HIGH GLAZING CHANNEL TYP. LEASE UNE 1/2" TEMPERED GLAZING GLAZING CUPS AT 6' -0" A.F.F. TYP. MALL NEUTRAL PIER 6" HIGH GLAZING CHANNEL TYP. STYLMARK 6" HIGH BASE ON LEASE UNE LANDLORD NEUTRAL PIER LEASE LINE r AA Storefront Elevation - EXISTING J 5 12 4 FEET ° v g f-53/4 10 5/8" 9 -0" Alft 14' -2 1/8" 0 .5 1 2 4 FEET Cl3) Storefront Floor Plan - EXISTING I—I I-1 I BRUTE .M I one Hour Profession Tauth Whitening 1' -3" D N/ 31' -4 3/4" EXISTING LEASE DIMENSION 6' -1" I CLEAR 31' -4 3/4" EXISTING LEASE DIMENSION 0 0 m OF DOOR FACE OF SOFFIT ABOVE LIMIT OF TENANT FLOORING LIMIT OF MALL FLOORING 1' -3" a 1 , "1- -i 14' -8 7/8" 1/2" TEMPERED GLAZING, IN CHANNEL TOP AND BOTTOM, TYP. NEW SIGN PANEL UNDER SEPARATE PERMIT 8' -8" 9 3/8" 1' - 0" LEASE LINE v LEASE LINE LANDLORD NEUTRAL PIER LEASE LINE SIGN CONTRACTOR TO RETURN BREAK METAL TO 6" BEHIND LEASE UNE ON EXPOSED SIDES OF SIGN MALL NEUTRAL PIER STYLMARK 6" HIGH BASE O R i , One Hour Pr'ofEws.a ®orml Tou'tFrr Wtii;k:err9i wj 426 Southcenter Mall Tukwila, WA 98188 with co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2009 City of Tukwila BUILDING DIVIRIflN Issues and Revisions No. Date Issues 1 09.09.09 2 09.29.09 Project Name BRITE SMILE Project Number 02008018.00 Description ELEVATIONS /SECTIONS Computer File CW05- 2008— A4.DWG Scale AS NOTED Template 4.3 (120101) A -4 6294 Architect Registration REGISTERED ARCHITECT 4 KEITH L. SMITH STATE OF WASHINGTON By Check PERMIT KLS PERMIT CORRECTIONS KLS RECEIVED CITY OF TUKWILA SFP ^ 0 2009 if ■IT /'►1"'AITr1 All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. • Note Key (Notes for existing conditions) 0 5/8" Fire Code Sheetrock 0 1/2" Fire Retardant M.D.F. Board ® .040 Break M ® 3 11 12 13 14 15 16 17 18 19 20 21 5/8" Metal Stud • Ga. Minimum at ® Suspended Gypsum Board Ceiling System With Hang Wire ® 4'—O" O.C. Each Way Suspend From Structure Above ® Existing Framing 07 Existing Gypsum Board ® 1/2" Tempered Glazing — 1/8" Air Space At Vertical Joints — No Silicone Typ. O 6" High x 2" Wide Glazing Channel with Anchor. 10 1 3/4" High x 2" Wide Glazing Channel. Reserved Reserved Wood Blocking (Fire Retardant) Neoprene Gasket Reserved 3 5/8" Metal Track 23 Glazing Vinyl, Inside and Outside 24 © 3 4" x 3 4 " x 1 8" Black Metal U— Channel © Down Light beyond © Existing Landlord Neutral Pier & finish to remain. 30 0 Storefront Sign Furnished and Installed by Tenant's Sign Contractor 3c 6" High x 3/4" wide Metal Trim. TOP OF GLAZING CHANNEL 11' -4" A.F.F. STOREFRONT ASSEMBLY 3 Typical Detail — EXISTING /t1 1 2 4 8 INCHES SOFFIT FINISHED CEIUNG HEIGHT 11' -4" A.F.F. SOFFIT FINISHED CEILING HEIGHT 10' -0" A.F.F. 0 O 6 0 011 BEYOND BEYOND BEYOND O BEYOND STOREFRONT ASSEMBLY • • \ • • • • 0 FINISHED FLOOR i 0 \ • • \. • • SIGN SOFFIT NOTE: SIGN CONTRACTOR TO SUBMIT SHOP DRAWINGS TO LANDLORD FOR APPROVAL PRIOR TO FABRICATION. 1 Section — EXISTING 0 2 4 8 1 INCHES Typical Detail — EXISTING 0 1 2 4 8 INCHES %% 00 0V7 I Ag • • • 2' -10 3/4" 0 O Oil • • O 6 1/2" MAX. LEASE UNE 3" 1 /2" NOTE: STOREFRONT SIGN LETTERS AND SIGN BACKER PANEL TO BE FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR. 00 r 0 MALL NEUTRAL PIER EXISTING MALL SOFFIT S UNDERSIDE OF MALL SOFFIT 13' -7" A.F.F. EXISTING NEW SIGN UNDER SEPARATE PERMIT SIGN BACKER PANEL SEE S TOP OF GLAZING CHANNEL 1O' -0" A.F.F. LEASE LINE FINISHED FLOOR ) METAL BAND SEE FOR ADDITIONAL ZION. a ±7 3/4" 10 5/8" STOREFRONT ASSEMBLY O(9 0 0 0 2 4 8 16 INCHES SOFFIT FINISHED CEILING HEIGHT 3 SIDES 3 SIDES 3 SIDES N 5 Typical Detail — EXISTING 0 0 Oa 0 SOFFIT BEYOND 1 1 BEYOND BEYOND BEYOND O BEYOND • • \ • • • • • 0 • • • • • • STOREFRONT GLAZING 2 C Section — EXISTING H I I I 0 2 4 8 16 INCHES STOREFRONT ASSEMBLY 0 2 4 8 16 INCHES 0 0 O 0 i 0 U 1 EXISTING MALL SOFFIT 0 6 Typical Detail — EXISTING 1--1 ° v AL UNDERSIDE OF MALL SOFFIT A.F.F. EXISTING SOFFIT I S TOP OF GLAZING CHANNEL 11' -4" A.F.F. LEASE UNE VtilEr FINISHED FLOOR MALL NEUTRAL PIER© BRiTEi. Ogle HOW' Profalsiortral TEt i [h Ta "d!E7i k.��r�i9i a 426 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2009 City of Tukwila BUILDING DIVISION Issues and Revisions No. Date 1 09.09.09 2 09.29.09 Project Name BRITE SMILE Project Number 02008018.00 :• ILiE V 1 6 1 7._ 6294 Description DETAILS /SECTIONS Computer File CW05— 2008 — A4. D WG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. A -4.1 Architect Registration REGISTERED ARCHITECT 4 - • KEITH L. SMITH 'STATE OF WASHINGTONI Issues By Check PERMIT KLS PERMIT CORRECTIONS KLS RECEIVED SEP : u 2009 PERMIT CENTER 0 2 SIDES el© 2 SIDES 0 2 SIDES 0 I II • Note Key (Notes for existing conditions) 0 5/8" Fire Code Sheetrock 0 1/2" Fire Retardant M.D.F. Board ® .040 Break M ® 3 11 12 13 14 15 16 17 18 19 20 21 5/8" Metal Stud • Ga. Minimum at ® Suspended Gypsum Board Ceiling System With Hang Wire ® 4'—O" O.C. Each Way Suspend From Structure Above ® Existing Framing 07 Existing Gypsum Board ® 1/2" Tempered Glazing — 1/8" Air Space At Vertical Joints — No Silicone Typ. O 6" High x 2" Wide Glazing Channel with Anchor. 10 1 3/4" High x 2" Wide Glazing Channel. Reserved Reserved Wood Blocking (Fire Retardant) Neoprene Gasket Reserved 3 5/8" Metal Track 23 Glazing Vinyl, Inside and Outside 24 © 3 4" x 3 4 " x 1 8" Black Metal U— Channel © Down Light beyond © Existing Landlord Neutral Pier & finish to remain. 30 0 Storefront Sign Furnished and Installed by Tenant's Sign Contractor 3c 6" High x 3/4" wide Metal Trim. TOP OF GLAZING CHANNEL 11' -4" A.F.F. STOREFRONT ASSEMBLY 3 Typical Detail — EXISTING /t1 1 2 4 8 INCHES SOFFIT FINISHED CEIUNG HEIGHT 11' -4" A.F.F. SOFFIT FINISHED CEILING HEIGHT 10' -0" A.F.F. 0 O 6 0 011 BEYOND BEYOND BEYOND O BEYOND STOREFRONT ASSEMBLY • • \ • • • • 0 FINISHED FLOOR i 0 \ • • \. • • SIGN SOFFIT NOTE: SIGN CONTRACTOR TO SUBMIT SHOP DRAWINGS TO LANDLORD FOR APPROVAL PRIOR TO FABRICATION. 1 Section — EXISTING 0 2 4 8 1 INCHES Typical Detail — EXISTING 0 1 2 4 8 INCHES %% 00 0V7 I Ag • • • 2' -10 3/4" 0 O Oil • • O 6 1/2" MAX. LEASE UNE 3" 1 /2" NOTE: STOREFRONT SIGN LETTERS AND SIGN BACKER PANEL TO BE FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR. 00 r 0 MALL NEUTRAL PIER EXISTING MALL SOFFIT S UNDERSIDE OF MALL SOFFIT 13' -7" A.F.F. EXISTING NEW SIGN UNDER SEPARATE PERMIT SIGN BACKER PANEL SEE S TOP OF GLAZING CHANNEL 1O' -0" A.F.F. LEASE LINE FINISHED FLOOR ) METAL BAND SEE FOR ADDITIONAL ZION. a ±7 3/4" 10 5/8" STOREFRONT ASSEMBLY O(9 0 0 0 2 4 8 16 INCHES SOFFIT FINISHED CEILING HEIGHT 3 SIDES 3 SIDES 3 SIDES N 5 Typical Detail — EXISTING 0 0 Oa 0 SOFFIT BEYOND 1 1 BEYOND BEYOND BEYOND O BEYOND • • \ • • • • • 0 • • • • • • STOREFRONT GLAZING 2 C Section — EXISTING H I I I 0 2 4 8 16 INCHES STOREFRONT ASSEMBLY 0 2 4 8 16 INCHES 0 0 O 0 i 0 U 1 EXISTING MALL SOFFIT 0 6 Typical Detail — EXISTING 1--1 ° v AL UNDERSIDE OF MALL SOFFIT A.F.F. EXISTING SOFFIT I S TOP OF GLAZING CHANNEL 11' -4" A.F.F. LEASE UNE VtilEr FINISHED FLOOR MALL NEUTRAL PIER© BRiTEi. Ogle HOW' Profalsiortral TEt i [h Ta "d!E7i k.��r�i9i a 426 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2009 City of Tukwila BUILDING DIVISION Issues and Revisions No. Date 1 09.09.09 2 09.29.09 Project Name BRITE SMILE Project Number 02008018.00 :• ILiE V 1 6 1 7._ 6294 Description DETAILS /SECTIONS Computer File CW05— 2008 — A4. D WG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. A -4.1 Architect Registration REGISTERED ARCHITECT 4 - • KEITH L. SMITH 'STATE OF WASHINGTONI Issues By Check PERMIT KLS PERMIT CORRECTIONS KLS RECEIVED SEP : u 2009 PERMIT CENTER RESTROOM PLANS AND DETAILS anir It O e EXISTING H. RESTROOM PLAN SCALE 1/2" = 1' -0" RESTROOM NOTES 3 -0" 36 " -42" A.F.F. LEVER HANDLES AT HANDICAPPED ACCESSIBLE HEIGHT ,r 5. TOILET ROOM FAN TO BE INTEGRALLY SWITCHED WITH TOILET LIGHT, AND VENTED TO THE OUTSIDE. 6. GYPSUM BOARD APPLIED TO PLUMBING WALLS SHALL BE WATER- RESISTANT. 7. COMPLY WITH ADA REQUIREMENTS AND LOCAL HANDICAPPED CODE. 8. PROVIDE A 4' -0" HIGH PLASTIC LAMINATE WAINSCOT WITH STAINLESS STEEL TRIM, ON ALL WALLS. 9. HOT WATER TANK CALL -OUT SEE 2.02. - Po 1. GRAB BARS 1 -1 /4 " -1 -1 /2" DIAMETER MOUNTED 1-1/2" FROM WALL. BARS SHALL BE CAPABLE OF SUPPORTING 300 LBS. LIVE LOAD WITHOUT PERMANENT DEFLECTION. PROVIDE BLOCKING IN EXISTING WALLS AS REQUIRED. 2. FLOORS SHALL BE SMOOTH, HARD, NONABSORBENT SURFACE. 3. PROVIDE 5" COVED SANITARY BASE. 4. DIMENSIONS, NOTES AND EQUIPMENT TYPICAL FOR ALL TOILET ROOMS UNLESS OTHERWISE NOTED. SEAT COVER ♦ DISP. ♦ CO M N) M a) I GWB (PAINTED ) ON 1/2" PLY -WD SHEATHING ON THIS WALL ONLY 3 -0" co GRAB BAR WAINSCOAT 1 H.C. RESTROOM ELEV. \„, SCALE 1/2" = 1' -0" TEMPERATURE SHIELDING ON SUPPLY AND DRAIN LINES H.C. RESTROOM ELEV. SCALE 1/2" = V-0" SOAP // DISP./ WAINSCOAT COVED SANITARY BASE 30" X 36" MIRROR LEVER CONTROLS TEMPERATURE SHIELDING ON SUPPLY AND DRAIN LINES O NOTE HANDICAPPED SIGNAGE WHERE REQUIRED. SUPPLIED AND INSTALLED BY CONTRACTOR "ASI" PLAQUE TYPE ACRYLIC WITH SUBSURFACE GRAPHICS TEXT: SC901 "WHITE ". FIELD SC905 "BLUE" 1/4" THICK, SURFACE APPLIED TO , CENTER SYMBOL ON DOOR, 60 ABOVE FINISHED FLOOR. (UNISEX REST ROOM) TOILET SIGNAGE Q0& UNISEX r =1' -D' 1 1/4" — 1 GRAB BAR, INSTALL PER MANUFACTURER SPECIFICATIONS SEE ACCESSIBILITY NOTES' SHEET A0.2 FOR ADDITIONAL REQUIREMENTS SECURE TO BACKING PER MANUFACTURER REQUIREMENTS, TYPICAL. SCHEDULED WALL, TYPICAL. 1 -1/2" GRAB BAR DETAIL ACTUAL SIZE COVED SANITARY BASE RESTROOM ACCESSORIES SCHEDULE MARK REMARKS HANDICAPPED ACCESSIBLE DESCRIPTION LAVATORY AND FAUCET WATER CLOSET GRAB BARS PAPER TOWEL DISPENSER TOILET PAPER DISPENSER MIRROR TOILET SEAT COVER DISPENSER SOAP DISPENSER DOOR SIGNS EXHAUST FAN FURN /INST. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. HANDICAPPED ACCESSIBLE 36" REAR / 42" SIDE 1 -1/2" DIA. SURFACE MOUNT, HANDICAPPED MOUNTING HEIGHT SURFACE MOUNT, HANDICAPPED MOUNTING HEIGHT 30" X 36" HANDICAPPED MOUNTING HEIGHT SURFACE MOUNT, HANDICAPPED MOUNTING HEIGHT MOUNT ON MIRROR FACE HANDICAPPED ACCESSIBLE SIGNAGE DIRECT WIRE TO LIGHT SWITCH FINISH WHITE /CHROME WHITE STAINLESS STEEL TEXTURED GRIP PLASTIC ACRYLIC PLASTIC ACRYLIC STAINLESS STEEL FRAME PLASTIC CLEAR ACRYLIC BLACK WITH WHITE LETTERING WHITE H.C. RESTROOM ELEV. SCALE 1/2" = V-0" HAN DICAPPED o ACCESSIBLE I LEVER HANDLES 4- T 36 " -42" A.F.F. vrow H.C. RESTROOM ELEV. SCALE 1/2" = 1' -0" GWB (PAINTED) WAINSCOAT 0 Co I R ITE Ono Hour P`rrafat4:sdon :l Tleuth �a�d hi;t:ef�l01 � 426 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2009 City of Tukwila BUILDING DIVIRIf1N - Ts`sLies and Revisions No. Date 1 09.09.09 Project Name BRITE SMILE Project Number 02006088.00 Description ENLARGED TOILET PLAN Computer File CW05- 2009— A5.DWG Scale AS NOTED Template 4.3 (120101) A -5 SW LE 6294 Architect Registration REGISTERED ARCHITECT ( KEITH L. SMITH STATE OF WASHINGTON Issues By Check PERMIT KLS RECEIVED CITY OF TUKWILA SF? F 0 2009 PERMIT CENTER All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. „0 - ,8 GWB (PAINTED) 3 -4" LEVER CONTROLS I r e 1 - 0 " WAINSCOAT i n 0 r r r RESTROOM PLANS AND DETAILS anir It O e EXISTING H. RESTROOM PLAN SCALE 1/2" = 1' -0" RESTROOM NOTES 3 -0" 36 " -42" A.F.F. LEVER HANDLES AT HANDICAPPED ACCESSIBLE HEIGHT ,r 5. TOILET ROOM FAN TO BE INTEGRALLY SWITCHED WITH TOILET LIGHT, AND VENTED TO THE OUTSIDE. 6. GYPSUM BOARD APPLIED TO PLUMBING WALLS SHALL BE WATER- RESISTANT. 7. COMPLY WITH ADA REQUIREMENTS AND LOCAL HANDICAPPED CODE. 8. PROVIDE A 4' -0" HIGH PLASTIC LAMINATE WAINSCOT WITH STAINLESS STEEL TRIM, ON ALL WALLS. 9. HOT WATER TANK CALL -OUT SEE 2.02. - Po 1. GRAB BARS 1 -1 /4 " -1 -1 /2" DIAMETER MOUNTED 1-1/2" FROM WALL. BARS SHALL BE CAPABLE OF SUPPORTING 300 LBS. LIVE LOAD WITHOUT PERMANENT DEFLECTION. PROVIDE BLOCKING IN EXISTING WALLS AS REQUIRED. 2. FLOORS SHALL BE SMOOTH, HARD, NONABSORBENT SURFACE. 3. PROVIDE 5" COVED SANITARY BASE. 4. DIMENSIONS, NOTES AND EQUIPMENT TYPICAL FOR ALL TOILET ROOMS UNLESS OTHERWISE NOTED. SEAT COVER ♦ DISP. ♦ CO M N) M a) I GWB (PAINTED ) ON 1/2" PLY -WD SHEATHING ON THIS WALL ONLY 3 -0" co GRAB BAR WAINSCOAT 1 H.C. RESTROOM ELEV. \„, SCALE 1/2" = 1' -0" TEMPERATURE SHIELDING ON SUPPLY AND DRAIN LINES H.C. RESTROOM ELEV. SCALE 1/2" = V-0" SOAP // DISP./ WAINSCOAT COVED SANITARY BASE 30" X 36" MIRROR LEVER CONTROLS TEMPERATURE SHIELDING ON SUPPLY AND DRAIN LINES O NOTE HANDICAPPED SIGNAGE WHERE REQUIRED. SUPPLIED AND INSTALLED BY CONTRACTOR "ASI" PLAQUE TYPE ACRYLIC WITH SUBSURFACE GRAPHICS TEXT: SC901 "WHITE ". FIELD SC905 "BLUE" 1/4" THICK, SURFACE APPLIED TO , CENTER SYMBOL ON DOOR, 60 ABOVE FINISHED FLOOR. (UNISEX REST ROOM) TOILET SIGNAGE Q0& UNISEX r =1' -D' 1 1/4" — 1 GRAB BAR, INSTALL PER MANUFACTURER SPECIFICATIONS SEE ACCESSIBILITY NOTES' SHEET A0.2 FOR ADDITIONAL REQUIREMENTS SECURE TO BACKING PER MANUFACTURER REQUIREMENTS, TYPICAL. SCHEDULED WALL, TYPICAL. 1 -1/2" GRAB BAR DETAIL ACTUAL SIZE COVED SANITARY BASE RESTROOM ACCESSORIES SCHEDULE MARK REMARKS HANDICAPPED ACCESSIBLE DESCRIPTION LAVATORY AND FAUCET WATER CLOSET GRAB BARS PAPER TOWEL DISPENSER TOILET PAPER DISPENSER MIRROR TOILET SEAT COVER DISPENSER SOAP DISPENSER DOOR SIGNS EXHAUST FAN FURN /INST. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. HANDICAPPED ACCESSIBLE 36" REAR / 42" SIDE 1 -1/2" DIA. SURFACE MOUNT, HANDICAPPED MOUNTING HEIGHT SURFACE MOUNT, HANDICAPPED MOUNTING HEIGHT 30" X 36" HANDICAPPED MOUNTING HEIGHT SURFACE MOUNT, HANDICAPPED MOUNTING HEIGHT MOUNT ON MIRROR FACE HANDICAPPED ACCESSIBLE SIGNAGE DIRECT WIRE TO LIGHT SWITCH FINISH WHITE /CHROME WHITE STAINLESS STEEL TEXTURED GRIP PLASTIC ACRYLIC PLASTIC ACRYLIC STAINLESS STEEL FRAME PLASTIC CLEAR ACRYLIC BLACK WITH WHITE LETTERING WHITE H.C. RESTROOM ELEV. SCALE 1/2" = V-0" HAN DICAPPED o ACCESSIBLE I LEVER HANDLES 4- T 36 " -42" A.F.F. vrow H.C. RESTROOM ELEV. SCALE 1/2" = 1' -0" GWB (PAINTED) WAINSCOAT 0 Co I R ITE Ono Hour P`rrafat4:sdon :l Tleuth �a�d hi;t:ef�l01 � 426 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2009 City of Tukwila BUILDING DIVIRIf1N - Ts`sLies and Revisions No. Date 1 09.09.09 Project Name BRITE SMILE Project Number 02006088.00 Description ENLARGED TOILET PLAN Computer File CW05- 2009— A5.DWG Scale AS NOTED Template 4.3 (120101) A -5 SW LE 6294 Architect Registration REGISTERED ARCHITECT ( KEITH L. SMITH STATE OF WASHINGTON Issues By Check PERMIT KLS RECEIVED CITY OF TUKWILA SF? F 0 2009 PERMIT CENTER All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. GWB (PAINTED) 3 -4" 3 ' - 6 " 1 - 0 " WAINSCOAT i n I o ° d- > > 1 -1/2" DIA. GRAB BARS �(, ♦ C TOILET PAPER m DISP. \- d- �� ♦ r T T RESTROOM PLANS AND DETAILS anir It O e EXISTING H. RESTROOM PLAN SCALE 1/2" = 1' -0" RESTROOM NOTES 3 -0" 36 " -42" A.F.F. LEVER HANDLES AT HANDICAPPED ACCESSIBLE HEIGHT ,r 5. TOILET ROOM FAN TO BE INTEGRALLY SWITCHED WITH TOILET LIGHT, AND VENTED TO THE OUTSIDE. 6. GYPSUM BOARD APPLIED TO PLUMBING WALLS SHALL BE WATER- RESISTANT. 7. COMPLY WITH ADA REQUIREMENTS AND LOCAL HANDICAPPED CODE. 8. PROVIDE A 4' -0" HIGH PLASTIC LAMINATE WAINSCOT WITH STAINLESS STEEL TRIM, ON ALL WALLS. 9. HOT WATER TANK CALL -OUT SEE 2.02. - Po 1. GRAB BARS 1 -1 /4 " -1 -1 /2" DIAMETER MOUNTED 1-1/2" FROM WALL. BARS SHALL BE CAPABLE OF SUPPORTING 300 LBS. LIVE LOAD WITHOUT PERMANENT DEFLECTION. PROVIDE BLOCKING IN EXISTING WALLS AS REQUIRED. 2. FLOORS SHALL BE SMOOTH, HARD, NONABSORBENT SURFACE. 3. PROVIDE 5" COVED SANITARY BASE. 4. DIMENSIONS, NOTES AND EQUIPMENT TYPICAL FOR ALL TOILET ROOMS UNLESS OTHERWISE NOTED. SEAT COVER ♦ DISP. ♦ CO M N) M a) I GWB (PAINTED ) ON 1/2" PLY -WD SHEATHING ON THIS WALL ONLY 3 -0" co GRAB BAR WAINSCOAT 1 H.C. RESTROOM ELEV. \„, SCALE 1/2" = 1' -0" TEMPERATURE SHIELDING ON SUPPLY AND DRAIN LINES H.C. RESTROOM ELEV. SCALE 1/2" = V-0" SOAP // DISP./ WAINSCOAT COVED SANITARY BASE 30" X 36" MIRROR LEVER CONTROLS TEMPERATURE SHIELDING ON SUPPLY AND DRAIN LINES O NOTE HANDICAPPED SIGNAGE WHERE REQUIRED. SUPPLIED AND INSTALLED BY CONTRACTOR "ASI" PLAQUE TYPE ACRYLIC WITH SUBSURFACE GRAPHICS TEXT: SC901 "WHITE ". FIELD SC905 "BLUE" 1/4" THICK, SURFACE APPLIED TO , CENTER SYMBOL ON DOOR, 60 ABOVE FINISHED FLOOR. (UNISEX REST ROOM) TOILET SIGNAGE Q0& UNISEX r =1' -D' 1 1/4" — 1 GRAB BAR, INSTALL PER MANUFACTURER SPECIFICATIONS SEE ACCESSIBILITY NOTES' SHEET A0.2 FOR ADDITIONAL REQUIREMENTS SECURE TO BACKING PER MANUFACTURER REQUIREMENTS, TYPICAL. SCHEDULED WALL, TYPICAL. 1 -1/2" GRAB BAR DETAIL ACTUAL SIZE COVED SANITARY BASE RESTROOM ACCESSORIES SCHEDULE MARK REMARKS HANDICAPPED ACCESSIBLE DESCRIPTION LAVATORY AND FAUCET WATER CLOSET GRAB BARS PAPER TOWEL DISPENSER TOILET PAPER DISPENSER MIRROR TOILET SEAT COVER DISPENSER SOAP DISPENSER DOOR SIGNS EXHAUST FAN FURN /INST. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. G.C. / G.C. HANDICAPPED ACCESSIBLE 36" REAR / 42" SIDE 1 -1/2" DIA. SURFACE MOUNT, HANDICAPPED MOUNTING HEIGHT SURFACE MOUNT, HANDICAPPED MOUNTING HEIGHT 30" X 36" HANDICAPPED MOUNTING HEIGHT SURFACE MOUNT, HANDICAPPED MOUNTING HEIGHT MOUNT ON MIRROR FACE HANDICAPPED ACCESSIBLE SIGNAGE DIRECT WIRE TO LIGHT SWITCH FINISH WHITE /CHROME WHITE STAINLESS STEEL TEXTURED GRIP PLASTIC ACRYLIC PLASTIC ACRYLIC STAINLESS STEEL FRAME PLASTIC CLEAR ACRYLIC BLACK WITH WHITE LETTERING WHITE H.C. RESTROOM ELEV. SCALE 1/2" = V-0" HAN DICAPPED o ACCESSIBLE I LEVER HANDLES 4- T 36 " -42" A.F.F. vrow H.C. RESTROOM ELEV. SCALE 1/2" = 1' -0" GWB (PAINTED) WAINSCOAT 0 Co I R ITE Ono Hour P`rrafat4:sdon :l Tleuth �a�d hi;t:ef�l01 � 426 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2009 City of Tukwila BUILDING DIVIRIf1N - Ts`sLies and Revisions No. Date 1 09.09.09 Project Name BRITE SMILE Project Number 02006088.00 Description ENLARGED TOILET PLAN Computer File CW05- 2009— A5.DWG Scale AS NOTED Template 4.3 (120101) A -5 SW LE 6294 Architect Registration REGISTERED ARCHITECT ( KEITH L. SMITH STATE OF WASHINGTON Issues By Check PERMIT KLS RECEIVED CITY OF TUKWILA SF? F 0 2009 PERMIT CENTER All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc.