Permit D09-197 - COURTYARD BY MARRIOTT - LOBBY AND PUBLIC SPACES
COURTYARD BY MARRIOTT 400 ANDOVER PK W D09 -197 Parcel No.: 2623049006 Address: 400 ANDOVER PK W TUKW Suite No: City.if Tukwila Tenant: Name: COURTYARD BY MARRIOTT Address: 400 ANDOVER PK W , TUKVVILA WA Owner: Name: HOSPITALITY INVESTMENTS Address: C/O ING CLARION PARTNERS , 2650 CEDAR SPRINGS RD #850 75201 Phone: Contact Person: Name: IVANA OSTIK Address: 15200 52 AV S , TUKWILA WA 98188 Phone: 206 - 766 -8300 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Contractor: Name: LAND -RON INC Address: 6753 KINSPOINTE PKWY #109 , ORLANDO FL 32819 Phone: 407 - 816 -7035 Contractor License No: LANDRI *911 QB DEVELOPMENT PERMIT Permit Number: D09 -197 Issue Date: 11/04/2009 Permit Expires On: 05/03/2010 Expiration Date: 11/02/2011 DESCRIPTION OF WORK: RENOVATION OF HOTEL LOBBY & PUBLIC SPACES. PUBLIC WORKS ACTIVITIES INCLUDE UPGRADE OF THE FIRE DEPARTMENT CONNECTION WITH STORZ KNOX LOCK. Value of Construction: $500,000.00 Fees Collected: $7,511.67 Type of Fire Protection: International Building Code Edition: 2006 Type of Construction: V- Occupancy per IBC: 0004 doc: IBC -10/06 * *continued on next page ** D09 -197 Printed: 11 -04 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Signature: doc: IBC -10/06 City o*I'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us to:R[2,A Permit Number: D09 -197 Issue Date: 11/04/2009 Permit Expires On: 05/03/2010 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t , performance of wojk. I am authorized to sign and obtain this development permit. Date: ,, Print Name: * 77 »() rU 7'' a This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -197 Printed: 11 -04 -2009 Parcel No.: 2623049006 Address: Suite No: Tenant: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 400 ANDOVER PK W TUKW COURTYARD BY MARRIOTT 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 11: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D09 -197 ISSUED 09/22/2009 11/04/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) D09 -197 Printed: 11 -04 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 ram) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 24: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 ram). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 25: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 26: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the doc: Cond -10/06 D09 -197 Printed: 11 -04 -2009 • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 29: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 30: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 31: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 32: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 33: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 34: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 35: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 36: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 - 575 -4407 for ordering information. 37: Every room or space that is an assembly occupancy shall have the occupancy load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (IFC 1004.3) 38: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 39: In occupancies of Groups A, E, I and R -1 and dormitories in Group R -2, curtains, draperies, hangings and other decorative materials suspended from walls or ceilings shall be flame resistant in accordance with NFPA 701 or be noncombustible. Where required to be flame resistant, decorative materials shall be tested by an approved agency and pass Test 1, as described in NFPA 701, or such materials shall be noncombustible. Reports of test results shall be prepared in accordance with NFPA 701 and furnished to the fire code official upon request. (IFC 805.1, 805.2) 40: The height of fire department connections (FDC's) shall be 36 to 48 inches above grade. 41: Fire department connections ( FDC's) shall be oriented in the direction of fire apparatus access, have a 4 foot clear doc: Cond -10/06 D09 -197 Printed: 11 -04 -2009 • o City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us space in front and to the sides of the connection, be appropriately signed, have the building address served by the FDC stenciled vertically in 3 -inch high white numbers on a "safety red" background directly beneath the hose connection facing the direction of vehicular access, and protected from potential vehicular damage. 42: The fire department connection (FDC) shall have a downward angle bend between 22.5 and 45 degrees, with a 5 -inch Storz fitting(s) and Knox FDC locking Storz cap. (NFPA 13- 6.8.3) (City Ordinance #2050) 43: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 44: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 45: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 46: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 47: The existing Fire Department Connection (FDC) shall have the siamese connection removed and replaced with Knox lock cap. Contact Tukwila Fire department for part ordering information. doc: Cond -10/06 * *continued on next page ** D09 -197 Printed: 11 -04 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: ,e4„ , 7Y )9U co 2 &/1 doc: Cond -10/06 D09 -197 Date: / ® � 7 ^v ordinances governing or local laws regulating Printed: 11 -04 -2009 Company Name: Mailing Address: E -Mail Address: Contact Person: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci. tukwila.wa. us Building Permit No lylCj 1 q 7 Meclhaliical Permit No! tit O q - 1 1 Plumbing/Gas Permit No. Public Works Permit No. Project No. . (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION I 1' King Co Assessor's Tax No.: Zlp 2- 3O 4' -lOO 1f Site Address: D O AW 6 11 17 -K. W V31 Suite Number:,[ Floor: N/ Tenant Name: GOV 1 ► �� �✓Y M OT �� New Tenant: ❑ Yes [eNo Property Owners Name: GOUi�Il� $Y / a4TT GLG o I N(� GGA oN P - ie7-N i S Mailing Address: IVO 1 l9 1 W �jr 14 W ILA-- WWA- q 1 t i et City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: IVAWA OT1 . Mailing Address: I5200 7e iso11T11 E - Mail Address: %V 3,11. A O Qo 3613 . cb111 GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record � /�!7 A-L time / dui'T .�T 92 e' /Z 1J - V V+J U r . C�, hVI ,`ij /. -�jv^ (/Vn State 0 Zip 1F 1 Contact Person: 1 1/W (N / Day Telephone: 1,46'766 0 0 Fax Number: 204 — 7 4 6 .Om ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: /Z0 7 /L7 'tsJ N i � f t� / (tsJ . Mailing Address: Zo '7OO /'t N T . N j �7/ O t g'jioN E -Mail Address: 14Y1 /''0b SOl? H: Appltcaaons \Forms- Applicanons On Line \2009 Appltcanons \1 -2009 - Pemut Application.doc Revised: 1 -2009 hh Day Telephone: Z06-766 -.6300 City State Zip Fax Number: ZO 6 7 -808a City Day Telephone: F ax Number: State Zip 1J _36y —�3f3 2pt -9 -e53 Page 1 of 6 • .1. Bxisting InteriorRemodel Addition to Existing • Structure , • . . • Nciv Type of Cpnstruction per . , ":-1 • ` Type of Occupancy per IBC I" Floor VP yr 30 cL litre 2 2 Floor . . •. 3roFl`oor „. -' . Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ Will there be new rack storage? ❑ Yes 1—L'Applications \Forms - Applications On L nc\2009 Applicaticns11 -2009 - Permit Applicatioadoc Revised: 1 -2009 bh Number of Parking Stalls Provided: Standard: Existing Building Valuation: $ Scope of Work (please provide detailed information): DIY0vf'flaN ar 1X1514J6 4o1 L Wel PPIBSIC SrAceS ❑.. No If yes, a separate permit and plan submittal will be required. Provide. All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the'principal owner lives in one of the dwellings as his'or her primary residence. Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If ''yes attach list of materials and storage locations on a separate 8-1/1" x 11 " paper including quantities. and Material Safety Data Sheets. SEPTIC SYSTEM On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I.HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: ' t4' Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). Mailing Address: (57740 52nd 501l77-/ Date Application Expires: I Date Application Accepted: fla}fIQ C. UNA-S H:Wpplications \Forms - Applications On Line\2009 Applications \I-2009 - Permit Applicatioadoc Revised: 1.2009 bh .e?9 TJZ- City Date: 9- 22 -0 �j Day Telephone: ,ZD1 - 76 6 -83D State Staff Initials: ( , ( Zip Page 6 of 6 Future Type: Qty Fixture Type: P Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per he Food -waste grinder, commercial Floor Drain ' Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks / Urinals `•.•ter Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water hea • r and/or vent Indu u: al waste treatment interc - i .er, including trap and vent, -, cept for kitchen type grease • terceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) R -,: air or alteration of ter piping and/or water eatment equipment ` I Repair or alte• tion of drainage or ven ` iping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective • . 'ce other than atmospheric -'` <.e vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacu breakers not included -• lawn sprinkler back' . w protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets I Valuation of Project (c'' Scope of Work (please p _. New puM13W C HA Applications On- Line\2009 Applications \1 -2009 Permit Application.doc Revised: 1 -2009 bh • PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: detailed information): N1V ik.c UN TO D LIDO 14e0100510 Pxl5Tlnr1 pu'n rya 1 y rr ,, 'ii w NEJ Building Use (per Int'l Building Cod - Occupancy (per Int' k Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas pip outlets be' s -: installed and the quantity below: Page 5 of 6 Parcel No.: 2623049006 Address: 400 ANDOVER PK W TUKW Suite No: Applicant: COURTYARD BY MARRIOTT Receipt No.: R09 - 01735 Payee: MARRIOTT • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 06182776 4,554.30 Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 RECEIPT Total: $4,554.30 Permit Number: D09 -197 Status: APPROVED Applied Date: 09/22/2009 Issue Date: Payment Amount: $4,554.30 Initials: WER Payment Date: 11/04/2009 11:23 AM User ID: 1655 Balance: $0.00 Account Code Current Pmts 4,549.80 4.50 Y ENT RECEIVED doc: Receipt -06 Printed: 11 -04 -2009 Parcel No.: 2623049006 Address: 400 ANDOVER PK W TUKW Suite No: Applicant: COURTYARD BY MARRIOTT Receipt No.: R09 -01476 Payee: JOHNSON BRAUND DESIGN GROUP TRANSACTION LIST: Type Method Descriptio Amount Payment Check 23682 2,957.37 Authorization No. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Initials: WER Payment Date: 09/22/2009 09:22 AM User ID: 1655 Balance: $4,554.30 Account Code Current Pmts 000/345.830 2,957.37 Total: $2,957.37 Permit Number: D09 -197 Status: PENDING Applied Date: 09/22/2009 Issue Date: Payment Amount: $2,957.37 PAYMENT RECEIVED doc: Receipt-06 Printed: 09 -22 -2009 Pr t: t. /,- .-� /,a, /,4 Type of Ins ion: 4 Address: / �l�Q 4�/i7 /l�Pd 4! Date Called: Special Instructions: Date Want d: /i.m iii // i p• Requester: Phone No Coq - 65. - 9/°y M - /C INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: — 4)/1"02'"e / ;1 0-/ /A/G "0" /"." >devi (s/A4i /4 14 ‘‘7 1vel/ f Inspect f• $ ' REINSPECTION E REQUIR Rr ior to inspectidn, fee must be .aid at 6300 Southcente Blvd., Sui a 100. Call to schedule reinspection. Receipt No.: 1 Da: Date: tiL COMMENTS: Type of Insp ti° r v i a / C O U di 6 h s, tiov — F , tv l9 l AI 0 alb Ci Add ye � v Y1c) Date Called: .0 F,,.t r- ;All / — ,l 1f Special Instructions: Date Wanted,: a.m. / / 1 e4l _. :7;0 ate (Ai /t - N,114 Phone No: 0.1/3' --'cif" f2‘,2_, . \ . , Prod ct: f / �� / L �eYer - + i o✓ /` ki /d !T Type of Insp ti° r v i a / Add ye � v Y1c) Date Called: Special Instructions: Date Wanted,: a.m. Requester: Phone No: 0.1/3' --'cif" f2‘,2_, INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. LJ Corrections required prior to approval. nspect L ' - - a J $60.11 REINSPECTION 'PEER pal. . t 6300 Southcenter Blvd., Receipt No.: Date: )_ 1-.10 UIRED. rior to inspection, fee must be to 100. Call to schedule reinspection. Date: Pr�oject: ! (.--- 06I 1.- 4,,7fr ,Grl�i o / Type of Inspection: //.� / /_/ f( - 0.c 9 OH t ! c I� ." Address: IC. A / 1) L Date Called: Special Instructions: • Date Wanted: /.- 6C /D am. p.m. Requester: Ph - 7/$— r2 6 2 L INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)4313670 Corrections required prior to approval. COMMENTS: (!) M T /2 pecto p 0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. eipt No.: Date: /- `° - i0 Date: ❑ Approved per applicable codes. I . dh., r. -=sue. rs_ COMMENTS: 0 ?�lGd/6% A (' -� /44l -- 4 Address: `i 00 iAN Dow kt. P tC ti■.) Date Called: Special Instructions: i -A /Pc /5" ile d PF6/ AJ i v .- T' f rit/ 'e a.m. Re ster: GG 1 ----79'16.1° d t Pro t: tViNrAtfb O tM INZ.fl Type of Inspection: IOT F R Avt4 1 I Address: `i 00 iAN Dow kt. P tC ti■.) Date Called: Special Instructions: i _g510Z Date Wanted a.m. Re ster: Phone No: -4L17- LI ac i INSPECTION RECORD Retain a copy with permit INSP: ION NO. PEWIT NO. CITY OF TUKWILA BUILDING DIVISION f-e. . 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 3670 Approved per applicable codes. nspec 'r Reo' No.: El Corrections required prior to approval. Date: ////‘ .00 REINSPECTION FE • EOUIRED. Ijf to inspection, fee must be Id at 6300 Southcenter Bl ., Suite 10 Call to schedule reinspection. Date: Project: /r 4 / Type of Inspection: A Aele j , \ Address: Date Called: Special Instructions: Date Wanted: ' /1 - 2� - t j'`, P.m. Requester: / Phone No: a'3 - 7(g)- ‘ 926 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION !- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Approved per applicable codes. /7 Corrections required prior to approval. f l COMMENTS: Inspecto Da 71 ( 9 .00 REINSPECTIO FEE REQU RED. Prior to inspection, fee must be d at 6300 Southcenter Blvd., S ite 100. Call to schedule reinspection. Rec'pt No.: (Date: Pro'ect: ),pr€ ley /17i9/r oTI Type of Inspection: /= 6 \ \l Address: 4' /14✓1)od/FR r o,4 c,.J Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No ..2/3 -'32 a_ INSPECTION RECORD --te Retain a copy with permit INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS:4 P —J f' /ZiL2'44 / Z/ /> $60 0 REINSPECTION FEE EQUIR . i. Prior to inspection, fee must be • peat 6300 Southcenter Blvo. Su' e 100. Call to schedule reinspection. ceipt No.: 'Date: Proaect: • C, ofi A t( . / /7l Type of Inspection: � » - ( W Address: y' a,'' // R / ma x w Date Called: Special Instructions: . Date : Wante / //./ / o 5 p.m. Requester: Phone No: /2/ -37/- 45 ( INSPECTION RECORD R etain a copy with permit INSPECTION NO. X4 9 - -X5' 7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 CQMMENTS: 1 In S► it / 3 31 0.00 REINSPEC ION FEE RE�UIRED. Prior to inspection, fee must be did at 6300 Southcenter Blvd Suite 100. Call to schedule reinspection. Rec-ipt No.: / (Date: Approved per applicable codes. D Corrections required prior to approval. Proj t: / {� . � ,i p r bq env( Type of Insp ec ion: r �cu fii Address: 900 A ?K1J Date Called: o i/0 - 7/oq Special Instructions: Date Wanted: v I lob �O 1 Elf; 5 Requester: 0 I d Phone No: a13 7 /k &9' INSPECTION RECORD Retain a copy with permit w PERMIT NO. 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 i& c Inspector: 5 Date: 1 € ( i _ O t O ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: lot, a y �,, , j y, V rtA6 i v i Q + + Type of Inspection: s=/} F c_ Address: U a0 A P w Suite #: Contact Person: 6(4. AI A- gS(.0 A.10, v Special Instructions: Phone No.: W 7 (7 - 7 3- //66 Needs Shift Inspection: Sprinklers: Fire Alarm: •( Hood & Duct: 1 Monitor: _ AI.5. _ Pre -Fire: Permits: Occupancy Type: (4) • INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF. TUKWILA FIRE DEPARTMENT $80.00 REINSPECTION FEE IREQ the'City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc ,/13/06 b ,ail_ 11) F - PERMIT NUMBERS 444 Andover Park East Tukwila, Wa: 98188 206 - 575 -4407 ri Corrections required prior to approval: COMMENTS: A1( Co-g /t 144.4 ,c"v'e ..4 /QV 0 .1 4 , 4 ' 'N • Inspector: Date: 2 ti .P Mrs.. 1.0 UIRED. You will receive an invoice from T.F.D. Form F.P. 113 Project: �► �{ +M,„,r;cst-/- Type of Inspection: Address: //d Suite #: o4PUV Contact Person 11 5 4 Sc 0 Special Instrucctions: Occupancy Type: Phone No.: Need s Shift Inspection Sprinklers: . Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: INSPECTION NUMBER Apprgved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT • Word/Inspection Record Form.Doc 1/13/06 61- 1 PRMIT' NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206=575 -4407 Corrections required prior to approval. COMMENTS: 4 Date: •- `/ :Hrs.: O $80.00 REIN PECTION FEE !REQUIRED. You will receive an invoice from e +City of Tukwila Finance Department. CaII to schedule a reinspection. T.F:D: Form F.P. 113 COMMENTS: Type of Inspectio : 4 / �,,.• C., N Address: YOp A p Suite #: • Special Instructions: r /e /4 t o -aim • l=�..A ' 404- O k, . Permits: Occupancy Type: D1 B lc_ '44 - rS GVyA yy 0 cc i .. r .• I.. .te P. o gr e e .ec1. st 5 c.ei...-E- / 4vt.,el..e., .s.,— , ct. G I ,..L0c, Project: ( ou J V ) 4 yVe c i a � Type of Inspectio : 4 / �,,.• C., N Address: YOp A p Suite #: Contact Person: 43- s 10 Pa N NAoJ Special Instructions: Phone No.: 1475:-..-4-7 1, , 14v b Needs Shift Inspection: • Sprinklers: Fire Alarm: .f Hood & Duct: Monitor: i Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 ri Approved per applicable codes. • , r.' INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT •Inspector: Date: J :Hrs.: 1 •'5- Oe A $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. CaII to schedule a reinspecfion. Word/Inspection Record Form.Doc 1/13/06 Doi - vo- Corrections required prior to approval. PERMIT NUMBERS T.F.D. Form F.P. 113 M1 Project: (o - e .., %.,„ 1Mu .Ir.o4-} Type of Inspection rtt2E P Are Alarm : Address: go Suite #: A. P Contact Person: VAN; it e Sc. \AO k0 h A5 ..--'-''--- Permits: Special Instructions: Phone No.: 20 (0° Sic— 2-c . E> c -. G b( Needs Shift Inspection: Sprinklers: %/ Are Alarm : Hood & Duct: Monitor: A. C- L. Pre -Fire: Permits: Occupancy Type: . INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 'Do9- q- - PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Corrections required prior to approval. COMMENTS: g r► r4A( � O IL 1 0 4. r c 4 I r ,•40 ► S 5 ved n. • • • • . — .., is • _. _ •. •..e....• Inspector:�� o . !Hrs.: $80.00 REINS • ECTION FEE ;REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection: Word/Inspection Record Form.Doc 1/13/06 Date: • T.F.D. Form F.P. 113 a Project: ( eve I-Ao S bi IN ra-H- Type of Inspection: c y t,z A Address: g Suite #: opt, Contact Person: r &,.I Pd Special Instrucctions: Phone No.: 7 06,....--7-7z _ - 7 5 0 1 Needs Shift Inspection: P Sprinklers: p . Fire Alarm: •4 Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: • • • INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Word/Inspection Record Form.Do 1/13/06 • -5- /9Z PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 n Corrections required prior to approval. COMMENTS: r 4 P r ► r• h a " , ica „�+ C, Hrs.. v p+ '$80.00 REINSPECTION FEE :REQUIRED. You will receive;an invoice from e ' of Tukwila Department. Call to schedule a reinspection: T.F.D. Form F.P. 113 COMMENTS: Type of Inspection: 4.pywI /e,..- 1 ( Q Address: goo Suite #: A 6'w Contact Person: o' Id A I c& ily,; 4 "lc [- di t I . Permits: Phone No.: ? / 5 / lg — v 4 2 w / •� v /� e _ 'alb .� .I ! S V` 1 �A Ar, . LA I / e — Ain. /9 sok .,..- .10-14.... r : 4,..; kliy 6-4-.... s . _ v e 0t 16-v f.v -avkos ' ! _ 4-~ v4. - - "Pig. a , w he iv -.t r.+ l O V &4A a 0- ,041.. -+■_R /4aJ<4 h`, ," ...... T'r try v 44.. - C014 - `-rta 4,,,,. ; /a A ' a .o k- 11-✓'7 oc le - / 9 6 4 , t' to...- 41 $ .1.40 . Project: Coo y,„ tOocrt Type of Inspection: 4.pywI /e,..- 1 ( Q Address: goo Suite #: A 6'w Contact Person: o' Id A I c& Special Instructions: Permits: Phone No.: ? / 5 / lg — v 4 2 Needs Shift I nspectio n: Sprinklers: Fire Alarm: _ Hood & Duct: Monitor: Pre -Fire: • Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 n Approved per applicable codes. INSPECTION RECORD Retain a copy with permit . CITY OFTUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc • 1/13/06 q- (5 - t PERMIT NUMBERS C orrections required prior to approval. Inspecto A 4W Hrs.: Date: 8 �1plt • $80.00 REINSPE ' ON FEE REQUIRED. You wild receive an invoice from ity of Tukwila Finance Department. Call to schedule a reinspection. :T:F.D. Form F.P. 113 COMMENTS: • .. _ k- d - - Address: Woo i�PL Suite #: - ?re).‘ Aza. emre■PC ra;+ ,, . A 4. 11 V` losol p• Ps) r PA- ■• . Phone No.: 2 1 1, — IS-SZ+ - .. .. • .,... 400e'e 4� L,,,;.;,. • -- a s - 1;;,.....i' _II- i • -1.. d Crif A: - ) • as e Jk --- - - - - -- -- ri"re ' /0 ✓ . ■4..4 a 4- o • ' e a- v Q ooc 5 to w.: 1Q 4 - f "it efli k o P Q ! el 4 , ee_ A is.,,., t 1�4W -elv f Nri'4 - , -- Pira . V J V A °&^e'vf 1. w , h v? - te 72-4 v i4PPItAime e o r 16 F rr‹. - Project: // © b r 4- arc, 14 `f s 0 Nj ) Type of Inspection: ` P isoitJ " riye 44 f- /�► hCav iww++o Address: Woo i�PL Suite #: Contact Person: v - - b\c, Ai, y 'ck Special Instructions:• .,.;, - Phone No.: 2 1 1, — IS-SZ+ - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: ' Pre -Fire: Permits: Occupancy Type: ; INSPECTION NUMBER Approved per applicable codes. Word /Inspection Record Form.Doc INISPECTION RECORD Retain a copy with permit 1/13/06 oft- s- di PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, Wa. 98188 206= 575 -4407 [xi, Corrections required prior to approval. I Inspector: V1AA 'A Date: 10 ;Hrs.: 01 $80.00 REINSP ON FEE iREQUIRED. You will receive an invoice City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: ( I ; 4 l y r c� 4— i- Type of Inspection: - k i.4 c,wJ Fire Alarm: Address: y aa Suite #: p f'v./ Contact Person: , , g de-to !a A le ' v; ". t Special Instructions: • Permits: Phone No.: 2- I-2 I ci - 4 • Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwil a, Wa: 98188 206 -575 -4407 Approved per applicable codes. COMMENTS: t►tead p�A�� �u.�,k�P 5 ,f,.hk/• I...A `�•w oiw cLra $ two '0.,4 I AAA Date: Hrs..•/ Inspector: 17.7( t 1 $80.00 REINSPECTION FEE REQUIRED. You will receive ;an invoice from e City of Tukwila Finance Department. CaII to schedule a reinspection. Word /Inspection Record Form.Doc . 1/13/06 PERMIT NUMBERS al Corrections required prior to approval. T.F:D. Form F.P. 113 .mss ...., [ - 4-_19 velr . Project: riA44,'‘AT covii- Type of Inspection: 4.0.19e0.4 Caoe.4 . Address: Vat> /1"." Suite #: Contact Person: Special Instructions: Phone No.: .26 , Needs Shift Inspection: Sprinklers: Fire Alarm: . Hood & Diict: Monitor: Pre-Fire:: Permits: Occupancy Type: INSPECTION NUMBER P P Approved per applicable codes. ; . INSPECTION RECORD Retain a copy with permit Oc) ?- 5 7 PERMIT NUMBERS ' CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 n Corrections required prior to approval. COMMENTS: ofe Chne;a1.. Inspector SO Date: z../414:71 Hrs.: $80.00 REINSPECTION FEEIREQUIRED. You will receivejan invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc • 1/13/06 T.F.D. Form F.P. 113 EQUIPMENT SCHEDULE N 019 EQUIPMENT CATEGORY ERINAIZEIIT 109 1 0014(0 0100? BREWER (8011-1101 SHOWN) BY STAREMES - NOM 110 M GUIS BY OWNER - MCC 10? MINER WON. TO 90<00 0??) Br OWNER - WEE 1 20100. VALIDATCR A DRAWER BY OWNER - tom LIB -8 FMB CORNIER BY GO - ANCIATCTINIAL LOLL 1 t -BAR NMI BY QC - 40091004.0141 MILLWORK 1 414014140 NUMERATOR LOT BY G.0 - ANCHNECTURN. LILLSONE IMEN MIER BY VAMP. - 0000 Kg Cipt1371.teirt,aint a me 209 ‘ RAU _ WITT 1000 WELL _ = SNELE 216 FRONT *014104 Br 0.0 - 400010010044. 091W00E 17 SI1EL MT 41 0<01.00 BY 0.0, - ARONIECTLPAL 222 _ 23 22 4< 0<4<00049< WASTE CIEETE SUITOR 225 4. ifxDoER MARE OMMOAND MIMI 229 T ■-... „t 1 0400< NAL BY onecs - c 911 632 LOT DRY NILLIFORE CASE t FREEZER - CUSS DOoN By GO - AROVIECTIMI. IMLWORK EMU. 613 t REFRIGERATOR - GLASS OCCR loosiNG 639 1 OVEN 640 3 SA MMUS • '1 NIKEC - NOT IN KITCHEN EQUIPMENT CONTRACT : . NO CHANGES SHALL BE LMAt •WITHOUT HEALTH DEPARTMENTAPPROVAL 11E1.1 No EouNMENT CATEGORY Do coFEr rum Isil. <01-101 Emu MINER vALANT0R 209 1107 RALF 228 GusSIVAINER <61001 400 BIC MAO TO 050E00 ELECTRICAL COMM 1MN ImERA. ccoLiell t ,p3 000403 13.0 SCHEDULE E At& AS FREEIBR - puss BooN 10.0 s- Is. • REFRoGERMR - GLAss Dom 10.6 1 s- INA 639 1400051004 0150 133 Is 120 9-16P ELECTRICAL CONNECTION SYMBOLS - - a 2101044 94 g OMIx 01010.24 ILRITRECUTAGE MEV CU! 0<09 0411 *AMOR • • EasiNs mac* 11/NALI 1.2 Immo moRMATE 6I0011040 CC '0 '4S101.. - EM '09 0 AI - 3720, CCIIRJO5A LOCA WT 03 13,1, NROPF9T AS NOTES: ELECTRICAL 1 &tor _ff.Aecgzgoimffir,o., oco„atILE, OPERATIONAL INSPECTION BY Ecupal - a10 ctmt.THE KING COUNTY HEALTH Arr OriS an to BOTTCli CI OURDEPARTMENT IS REQUIRED PRIOR ar° d ' °° ' FINIC *ALL TO OPERATION. APPLICANT PLAN SET IS REQUIRED TO BE AVAILABLE ON SITE DURING THAT INSPECTION. Equipment Layout Scae 1/4" = 1'- 0" Electrical Rough-In's Scale 1/4" = 1'-- SEATT Dept By — • INSHEL/ CEANC F . 0, 30. NOT Coned Contractor to 110191 md INSTALL 121 NALL BACKING NOM All IN IVI.LOAEXING most met) LOCk CECES and REGURNENTS NOT ALL CIAMONS cre glop to INSHI:11 NALL APPROVED SUBJECT TO ORDINANCE SEP 182O -KING CO Pilo Health IANE AGASID 17121 - sit. 1 I, b 016.91- PLUMBING NOTES: NOTII All DINNSIONS ore top to rINSIED BALL PLUMBING SCHEDULE cLT !Wk : • 0021114<44140 3±10<1004 f , 11: 5U 1k(II on 'Corm MEV EMU M O -NCR SNOONOr3/6 • 000r1 P NCA 204 ZEBREsso uNrr WAUR FILTER 3/6 24 3/5 BRAIN TO FS ▪ B 73EvEZAGE COOLER 222 MIDS. 3/3 12 224 'BLENDER STATION CLEssrasNER _ . GHQ ILO DIAN 12'. 12'10002 gt MU GUI iota Mali GOQI SES OUT 6 AALI BRANDI 10 CaNtiC511 MOVE DOD uo a CUD 1141ER KAER 3/09 12 3/0 12 PLUMBING CONNECTION SYMBOLS I. 115111(11(11 ACCEMCGES 40 MVO PROVIDED LOOSE WM (1220SERVO C0*101 - BY RAW 0210ACO 11119111C 021 Et All KAIER41S1E LNES PRO 10 Bra cowcat; to Ft:coma Ectsttoo - et, Floittic cattoActat 0140111:11 TO ILL WWI - BY RIMING CODUCCR ( Au NECESSARY TRIPS. PRES:411 IEDUONG WOES. 4111•15 04)400 <10... 10 NUE FBA( °MECUM ro MAIM 'CI BE PROKBED MULLED BY Inull3NC 0:10BAcIOR 1 ORM TO ITO I 16 1 -I /10RAIN To Fs --I /211A, INN: DRAIN TO IS • I SEE MANUFACTURER CUT SHEET FOR ALL • DROP-15 SPECIFICATIONS Special Conditions '4 1/4" = - 0" besclft- 1 Plumbing Rough-In's Scale 1/4" = - 0" i FOODSER94CE EQUIPMENT PROCUREMENT ,Sc DESIGN - HOTEL DEPARTMENT i -- - - - ..,... , ...... ...- : Jackie Dan a Notional Accounts ['.14-117 Douglas—R-6- .. -- Jc`i Alkinson Project Manager Projec Manager 3 :... : 1.4331 • 12521 Amherst Drive Austin. TX 78127-4111 5'2 303 311 Once 5 R E VI 'S CN Dale 00<5< /..:9 VI BISTRO & MET ECUPMENT LAYCLF, SPECIAL CONDIT1CNS, ELEC11ICAL PAIRING RCUGH-0S SB - 1 DRAINBOARDS, UTENSIL RACKS, OR TABLES LARGE ENOUGH TO •ACCOMMODATE ALL SOILED AND CLEANED ITEMS'SHALL BE PROVIDED FOR .NECESSARY UTENSIL HOLDING ...BEFORE CLEANING AND AFTER 'SANITIZING. • ". PLUMBING SYSTEMS SHALL BE DESIGNED, • CONSTRUCTEDND `INSTALLED ACCORDING to LAW(APPLICABLE LOCAL . FEDERAL STATUES, 'REGULATIONS AND ORDINANCES) „.-- • • FOOD SERVICE OPERATION AREA FLOORS, FLOOR COVERINGS, WALLS, WALL - COVERINGS, AND CEILINGS SHALL BE - DESIGNED, CONSTRUCTED AND INSTALLED' • SO THEY ARE SMOOTH, DURABLE AND EASILY 'CLEANABLE. LtickEPS 04“61 SUITABLE FACILITIES SHALL BE PROVIDED FOR 1 S TOkA GE OF tit4PL:b POSSESSIONS • . , RES TNO OM & KITCHEN HAND WASH SINKS SHALL BE EQUIPPED TO PROVIDE WATER AT kTEMPERATURE OFAT LEAST 100 DEGREES'FAHRENHEIT.THROUGH A MIXING'VALVE OR COMBINATION FAUCET. SELF ' CLOSING OR METERING FAUCETS SHALL PROVIDE A FLOW OF WATER FOR AT LEAST 15 SECONDS. - FOOD, FOOD PREPARATION AND:FOOD - S ERVICE EQUIPMENT STORAGE AREAS': E PROHIBIT UNDER SEWER LINES ,THAT.AiRE NOT SHIELDED 'INTE 147 POTENTIAL BE ADVISED THAT THE NEW WASHINGTON - . - — _ • STATE FOOD CODE REQUIRES-, • _ COMMERCIAL REFRIGERATION. HOLD _ FOOD -At-4 ,DEGREES FAHRENHEIT OR BELdWin "(DOWN FROM 45 DEGREES) ; . . Food eqUipment`that is certified c tifiedfor itatiob by : an American National Standards Institute (ANSI)I iddedited.ceitifiCation prdgram will comply with the food ecide,Oqui utensil material: construction and ilasi6Krecjiiite'inerits. r" EXERCISE EXI ROOM MEETING l ROOMS 20 10 bitea LING riozivr p EXIT EXITING PLAN FOR INFORMATION ONLY ILIA ISSUEIREV1SlONS ISSUE TOHPC 06.08{ MI PROGRESS GET 08 PERMIT SET 08.1205 MS REVISION 0804-01 LL W z 161 O O Wm W I m o o ul .3 J U co PROJECT•FILE 0921.02G001•EV0' DRAWN BY HLO TRLE MEANS OF EGRESS EEG0C Hi Joanna, Thanks Bryan »> Joanna Spencer 09/22/2009 3:25 PM »> Hello - Are they current on their backflows ? Do they have a single or double for fire ? Thanks, Joanna • • Joanna Spencer - Re: Courtyard by Mariott Hotel @ 400 APW D09 -197 From: Bryan Still To: Joanna Spencer Date: 09/23/2009 10:39 AM Subject: Re: Courtyard by Mariott Hotel @ 400 APW D09 -197 CC: Han Kirkland 2" DCVA irrigation 4" RPBA domestic 8" fire (failed last test) Need Knox lock storz connection on FDC currently a dual siamese. AMR deduct o.k. None of the devices are current they were due this month (September). Page 1 of 1 :\Documents and Settings \joanna.TUKWILA\Local Settings \Temp\XPgrpwise \4A... 09/24/2009 P ER�i i► SPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D09 -197 DATE: 09 -22 -09 PROJECT NAME: COURTYARD BY MARRIOTT SITE ADDRESS: 400 ANDOVER PK 1411J X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: uil I g ivisi n q� -6q *Ala rks Complete 1 quvl ,u /,4 ( 1-)40 �p Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 09 -24 -09 Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 14 Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: Documents /routing slip.doc 2 -28 -02 n S/( Planning Diivision Permit Coordinator 11 Not Applicable DUE DATE: 10-22 -09 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 3 3 Sink, Clinic flushing 8 8 Sink, kitchen 3 2 % I Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 Water closet, tank or valve, >1.6 GPF 8 4 La King County Department of Natural Resources and Parks Wastewater Treatment Division Total No. of Fixture Units 20 10SR /Rev Q /n71 Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type boo ANtzvlte. WEST Property Street Address Tf�1 City u it State L 1>k g NW/WW C k ING CiAtioN Subdivision Name Lot # Subdiv. # A��ii /tn ,t" Block # Building Name WUR /�'o By Iv I i1 (if applicable 1 Owner's Phone Number (with Area Code) Property Contact Phone Number (with Area Code) Owner's Mailing Address yAY 1L as zthavc- A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE r,2 RCE gF,l W Property Tax ID # Party to be Billed (if different from owner) City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre- existing building on this property. Credit for a demolition may be given under some circumstances. Demolition of pre- existing building? ❑ Yes ❑ No Was building on Sanitary Sewer? ❑ Yes ❑ No Was Sewer connected before 2/1/90? ❑ Yes ❑ No Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? ❑ Yes ❑ No B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day)•_ 187 C. Total Residential Customer Equivalents: (add A & B) A B 2 RCE RCE Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Signature of Owner /Representative r / ' » i 1y -- Print Name of Owner /Representative 14 ' 7746X t. 80110,5 Date 9 -22 -D9 Whits — Kinn r :ne.nty Vnlln.0 — 1 n,ni co..,nr Ann., 0 ■..4 _ Q ,.i.,, r`,,.,.....e• .acs, - . ,.. rte`. Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO W150039391 11/02/2009 C Can $12,000.0011 /02/2009 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 AMERISURE MUTUAL INSURANCE COM 28618 10/31/200910/31 /2010 $1,000,000.0011 /02/2009 Name Role Effective Date Expiration Date KARPUIK, RONALD H PRESIDENT 11/02/2009 KARPUIK, ROY H TREASURER 11/02/2009 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LRI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company LAND -RON INC UBI No. 4078167035 Status 6753 KINSPOINTE PKWY #109 ORLANDO FL 32819 OUT OF STATE Corporation LAND -RON INC License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602957459 ACTIVE LANDRI *911QB CONSTRUCTION CONTRACTOR 11/2/2009 11/2/2011 GENERAL UNUSED Business Owner Information Bond Information Insurance Information • https://fortress.wa.gov/lni/bbip/Detail.aspx • Page 1 of 1 11/04/2009 OWNER Courtyard by Marriott,LLC c/o ING Clarion Partners 2650 Cedar Springs Rd., Ste.850 Dallas, TX 75201 PROJECT DIRECTOR Kurt Miller Architecture & Construction Marriott International 10400 Fernwood Rd., Dept 70/103.49 Bethesda, MD 20817 PH: 301- 380 -6206 F: 301 - 644 -7095 Kurt.Miller @Marriott.com ARCHITECT Greg Allwine, Architect 15200 52nd Avenue South - Suite 200 Seattle, WA 98188 PH: 206-766-8300 F:206- 766 -8080 grega @jbdg.com M.E.P ENGINEER Robison Engineering 20300 19th Avenue NE Shoreline, WA 98155 PH: (206) 364 -3343 mrobison @robisonengineering.com FOOD SERVICE CONSULTANT Concept Services Jackie Damra 12521 Amherst Austin, TX 78727 PH: (512) 343 -3100 GENERAL CONTRACTOR TBD FILE COPY Permit No. toq �a Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fie ' Copy and cond ions is acknowledged: By Date: /1 9-- City Of Tukwila BUILDING DIVISION Lobby Reinvention of SEATTLE SOUTHCENTER, WA PROJECT DIRECTORY GENERAL NOTES 1) ALL WORK TO BE DONE IN AN APPROVED WORKMANLIKE MANNER AND SHALL BE IN ACCORDANCE WITH GOVERNING CODES & REGULATORY AGENCIES. 2) OWNER TO OBTAIN ALL PERMITS & COMPLY WITH ALL REQUIREMENTS OF LICENSING AGENCIES. CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 3) AREA AND DIMENSIONS: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL AREA TAKEOFFS AND DIMENSIONS BY MAKING HIS OWN FIELD MEASUREMENTS BEFORE STARTING WORK OR ORDERING MATERIALS. THE REMOVAL AND INSTALLATION OF MECHANICAL, ELECTRICAL, PLUMBING AND ARCHITECTURAL ITEMS MAY REQUIRE THE PENETRATION OR REMOVAL OF FLOORS, CEILINGS AND WALLS OF ADJACENT ROOMS AND FLOORS. PATCH AND FINISH ALL EXISTING SURFACES THAT ARE DISTURBED DURING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4) CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES. TAKE PRECAUTIONS AS NECESSARY TO PROTECT THEM. REPAIR ALL UTILITIES DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 5) ALL FINISHES O AS SELECTED BY OWNER, AND SIMILAR TO THE MARRIOTT COURTYARD RENOVATION PROTOTYPE FINISH SCHEDULE. 6) EXTEND CIRCUITS TO EXISTING FIXTURES TO REMAIN WHERE EXISTING WHERE EXISTING CIRCUITS ARE INTERRUPTED BY REMODEL WORK. 7) PRIOR TO DEMOLITION GC TO FIELD VERIFY WALLS, COLUMNS AND ALL ELEMENTS TO BE DEMOLISHED ARE NON - STRUCTURAL. IF WALLS, COLUMNS OR OTHER STRUCTURAL ELEMENTS ARE FOUND WITHIN THE PROPOSED DEMOLITION AREA, OR EXISTING CONDITIONS VARY FROM PLANS, NOTIFY THE PROJECT DIRECTOR BEFORE PROCEEDING. 8) INFORMATION SHOWN ON DETAILS & ENLARGED PLANS SUPERCEDES SMALLER SCALE PLANS. ABBREVIATIONS CENTER LINE ACT ACOUSTICAL CEILING TILE AFF ABOVE FINISHED FLOOR ALUM ALUMINUM CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED CLR CLEAR, CLEARANCE COL COLUMN CPT CARPET ELEC ELECTRIC(AL) EXT EXTERIOR EQ EQUAL EXG EXISTING FD FLOOR DRAIN FEC FIRE EXTINGUISHER CABINET GC GENERAL CONTRACTOR GWB GYPSUM WALLBOARD GYP GYPSUM HVAC HEATINGNENTILATION /AIR CONDITIONING MAX MAXIMUM MEP MECHANICAL /ELECTRICAL /PLUMBING MI MARRIOTT INTERNATIONAL MIN MINIMUM MTL METAL NIC NOT IN CONTRACT NTS oC OPP OFCI PD PLAM PLWD PNT PT RCP REF REQ'D RM SC SPEC SS TYP UON V.I.F. VWC. W/ WD WPT NOT TO SCALE ON CENTER(S) OPPOSITE HAND OWNER FURNISHED, CONTRACTOR INSTALLED PROJECT DIRECTOR PLASTIC LAMINATE PLYWOOD PAINT PORCELAIN TILE REFLECTED CEILING PLAN REFER(ENCE) REQUIRED ROOM SOLID CORE SPECIFICATION STAINLESS STEEL TYPICAL UNLESS OTHERWISE NOTED VERIFY IN FIELD VINYL WALLCOVERING WITH WOOD SIMULATED WOOD PORCELAIN TILE SUMMARY OF WORK FOR BUILDING DEPARTMENT REVIEW SITEWORK This building is existing. No exterior work on the building is included in this project. Extent of site work to include extension of gas line from exterior wall of fireplace for future optional firepit installation. LOBBY The lobby work consists of removal of existing NON - structural* walls, millwork and wall and floor finishes. New construction to include new floor and wall finishes, new millwork, furnishings and equipment installed throughout the space. Existing ceiling including mechanical, alarm and fire safety devices to remain and ceiling to be painted. Minor ceiling patching and device relocation as needed in areas of demolition. Lighting to remain with exception of several light fixtures replacement with new fixtures of lower wattage. New Lobby areas to include: • Reception with registration millwork to replace existing Front Desk • Market - relocated existing display refrigerator /freezer and replace millwork. • GoBoard /Business Center with new millwork and FF &E to replace existing Business Library • Cafe Dining with new millwork, s- service counter,and FF &E seating • Media Pods with new FF &E seating/TV • Home Theater area with new FF &E seating and TV • Lounge FF &E ELECTRICAL Minor electrical re- location is required as part of the wall relocations. New circuits are added for new service counter equipment. Electrical load of the building remains substantially unchanged. PLUMBING Minor plumbing lines adjustment and extensions as needed per new equipment in service counter area. MEETING ROOMS & BOARD ROOM Meeting rooms to receive new carpet and vinyl wallcovering. Lighting to be replaced with lower wattage fixtures. Alarm /fire safety devices to remain unchanged. EXERCISE ROOM Exercise room to receive new resilient floor covering, new vinyl wallcovering, new TV and new ceiling lights replacement with fixtures of lower wattage. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: N M echanical iectrical bing rPt a s Piping City of Tukwila BU!LD1NG DIVISION SYMBOLS LEGEND FINISH TAG REVISION TAG DOOR TAG ACCESSIBLE UNIT HEARING IMPAIRED UNIT WALL PARTITION TYPE REFER TO SHEET L401 DUPLEX OUTLET SWITCH DATA /PHONE JACK 001 C� KEYNOTE FF &E REFERENCE # x -xxx -- XX' —X" FLOOR SLAB SHEET NO. ELEVATION MARK ELEVATION TAG ENLARGED DETAIL MARK SECTION MARK DETAIL NO. DETAIL NO. DETAIL AREA SHEET NO. DETAIL NO. CODE INFORMATION JURISDICTION: HEALTH DEPARTMENT: BUILDING INFORMATION: BUILDING CODE: Plumbing code: Mechanical code: Electrical code: Accessibility Code: ORIGINAL BUILDING CODE: ORIGINAL BUILDING CONST. TYPE: CURRENT BLDG. CONST. TYPE: USE GROUP: LOBBY RENOVATED AREA (A3): Total Square Footage of Building BLDG. AREAS: OCCUPANCY SEPARATION: MEANS OF EGRESS: FINISHES: No. of Guestrooms Accessible Guestrooms (RIS) VICINITY MAP CITY OF TUKWILA COMMUNITY DEVELOPMENT 6300 SOUTHCENTER BLVD., #100 TUKWILA, WA 98188 PH: 206 -431 -3670 PUBLIC HEALTH SEATTLE & KING COUNTY IBC 2006 UPC 2006 IMC 2006 NEC 2005 / WA STATE ENERGY CODE IBC 2006 Chapter 11; ICC / ANSI 1 -2003 1997 Uniform Building Code w/ WA Amendments TYPE V, 1 hour TYPE VA A -3/R -1 /B -2 5309 SF 91,534 SF PUBLIC GUEST FIRST FLOOR GUEST SECOND FL. GUEST THIRD FL. TOTAL ALL AREAS 1 HOUR REFER TO FINISH INDEX 137 TOTAL 8 TOTAL (2 R.I.S) LOCATION OF PROJECT 13,290 SF 25,492 SF 26,376 SF 26,376 SF 91,534 SF UNMODIFIED BY THE CONSTRUCTION. OCCUPANT LOADS, DIRECTION OF TRAVEL, NUMBER OF EXITS, SEPERATION OF EXITS IS UNCHANGED. INDEX OF DRAWINGS G000 COVER SHEET AND GENERAL NOTES G001 EXISTING SITE PLAN G002 S- SERVICE COUNTER MENUS, INTERIOR GRAPHICS G003 EXISTING KITCHEN G004 MEANS OF EGRESS LOBBY L101 L102 L103 L104 L105 L106 Li07 L108 L109 L110 L201 L401 L402 L403 500a 500b 501 502 X03 504 .595 -- 506 507 508 509a 509b LOBBY DEMOLITION FLOOR PLAN LOBBY REFLECTED CEILING DEMO PLAN LOBBY NEW FLOOR PLAN LOBBY NEW REFLECTED CEILING PLAN LOBBY FLOOR FINISH PLAN LOBBY FURNITURE PLAN NOT USED EXERCISE ROOM MEETING ROOM & CORRIDOR RECEPTION AREA & MARKET ENLARGED PLANS, ELEVS & DETLS LOBBY INTERIOR ELEVATIONS LOBBY PARTITION TYPES, DETAILS & DOOR SCHEDULE LOBBY CEILING DETAILS LOBBY SUNKEN LOUNGE DETAILS WELCOME PEDESTALS DTLS WELCOME PEDESTALS DTLS FOCAL WALL DTLS GOBOARD & COFFEE DTLS NOT USED BUSINESS CENTER & QUICK PRINT DTLS NOT USED THE MARKET SECTIONS MEDIA PODS DTLS COMMUNAL TABLE DTLS S- SERVICE COUNTER DTLS S- SERVICE COUNTER SECTIONS M.E.P. E000 SHEET INDEX, LEGEND, NOTES E001 LUMINAIRE SCHEDULE, CASEWORK LIGHTING E100 LOBBY PLAN LIGHTING E200 LOBBY PLAN POWER - DEMO E201 LOBBY PLAN POWER - NEW E210 S- SERVICE COUNTER PLAN POWER E300 MEETING ROOM PLANS - LIGHTING / POWER E400 EXERCISE ROOM PLANS - LIGHTING / POWER E500 SPECIFICATIONS P101 S- SERVICE COUNTER PLUMBING P102 LOBBY EXISTING FLOOR PLAN M101 MECHANICAL DEMOLITION FLOOR PLAN M102 MECHANICAL CEILING PLAN M103 PARTIAL EXISTING HVAC PLAN KEY PLAN EXERCISE RM MEETING ROOMS BOARD RM LOBBY REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 ��. tok City of Tukwila BUILDING DIVISION RECEIVED SEP 2 2 2009 PEHIVIIT CENTER SHEET 3380 = I— i u Q o - Z I.J. O < z > - . }- w co Z � wQ I ca m D O 0 J U b409. 197 111 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT If/ R• L. ALLWINE ATE OF WASHINGTON ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 rn - o O O PROJECT -FILE 0921.02 0921.02 -G000 DRAWN BY HLB TITLE COVERSHEET AND GENERAL NOTES 0 0) 0 0 w Ff. GO00 OWNER Courtyard by Marriott, LLC c/o ING Clarion Partners 2650 Cedar Springs Rd., Ste.850 Dallas, TX 75201 PROJECT DIRECTOR Kurt Miller Architecture & Construction Marriott International 10400 Fernwood Rd., Dept 70/103.49 Bethesda, MD 20817 PH: 301- 380 -6206 F: 301 - 644 -7095 Kurt.Miller @Marriott.com ARCHITECT Greg Allwine, Architect 15200 52nd Avenue South - Suite 200 Seattle, WA 98188 PH: 206-766-8300 F:206- 766 -8080 grega @jbdg.com M.E.P ENGINEER Robison Engineering 20300 19th Avenue NE Shoreline, WA 98155 PH: (206) 364 -3343 mrobison @robisonengineering.com FOOD SERVICE CONSULTANT Concept Services Jackie Damra 12521 Amherst Austin, TX 78727 PH: (512) 343 -3100 GENERAL CONTRACTOR TBD PROJECT DIRECTORY GENERAL NOTES 1) ALL WORK TO BE DONE IN AN APPROVED WORKMANLIKE MANNER AND SHALL BE IN ACCORDANCE WITH GOVERNING CODES & REGULATORY AGENCIES. 2) OWNER TO OBTAIN ALL PERMITS & COMPLY WITH ALL REQUIREMENTS OF LICENSING AGENCIES. CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 3) AREA AND DIMENSIONS: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL AREA TAKEOFFS AND DIMENSIONS BY MAKING HIS OWN FIELD MEASUREMENTS BEFORE STARTING WORK OR ORDERING MATERIALS. THE REMOVAL AND INSTALLATION OF MECHANICAL, ELECTRICAL, PLUMBING AND ARCHITECTURAL ITEMS MAY REQUIRE THE PENETRATION OR REMOVAL OF FLOORS, CEILINGS AND WALLS OF ADJACENT ROOMS AND FLOORS. PATCH AND FINISH ALL EXISTING SURFACES THAT ARE DISTURBED DURING CONSTRUCTION, UNLESS NOTED OTHERWISE. 4) CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES. TAKE PRECAUTIONS AS NECESSARY TO PROTECT THEM. REPAIR ALL UTILITIES DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 5) ALL FINISHES C AS SELECTED BY OWNER, AND SIMILAR TO THE MARRIOTT COURTYARD RENOVATION PROTOTYPE FINISH SCHEDULE. EXTEND CIRCUITS TO EXISTING FIXTURES TO REMAIN WHERE EXISTING WHERE EXISTING CIRCUITS ARE INTERRUPTED BY REMODEL WORK. 7) PRIOR TO DEMOLITION GC TO FIELD VERIFY WALLS, COLUMNS AND ALL ELEMENTS TO BE DEMOLISHED ARE NON - STRUCTURAL. IF WALLS, COLUMNS OR OTHER STRUCTURAL ELEMENTS ARE FOUND WITHIN THE PROPOSED DEMOLITION AREA, OR EXISTING CONDITIONS VARY FROM PLANS, NOTIFY THE PROJECT DIRECTOR BEFORE PROCEEDING. INFORMATION SHOWN ON DETAILS & ENLARGED PLANS SUPERCEDES SMALLER SCALE PLANS. ABBREVIATIONS CENTER LINE ACT ACOUSTICAL CEILING TILE AFF ABOVE FINISHED FLOOR ALUM ALUMINUM CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED CLR CLEAR, CLEARANCE COL COLUMN CPT CARPET ELEC ELECTRIC(AL) EXT EXTERIOR EQ EQUAL EXG EXISTING FD FLOOR DRAIN FEC FIRE EXTINGUISHER CABINET GC GENERAL CONTRACTOR GWB GYPSUM WALLBOARD GYP GYPSUM HVAC HEATINGNENTILATION /AIR CONDITIONING MAX MAXIMUM MEP MECHANICAL /ELECTRICAUPLUMBING MI MARRIOTT INTERNATIONAL MIN MINIMUM MTL METAL NIC NOT IN CONTRACT Lobby Reinvention of SEATTLE SOUTHCENTER, WA NTS OC OPP OFCI PD PLAM PLWD PNT PT RCP REF REQ'D RM SC SPEC SS TYP UON V.I.F. VWC W/ WD WPT NOT TO SCALE ON CENTER(S) OPPOSITE HAND OWNER FURNISHED, CONTRACTOR INSTALLED PROJECT DIRECTOR PLASTIC LAMINATE PLYWOOD PAINT PORCELAIN TILE REFLECTED CEILING PLAN REFER(ENCE) REQUIRED ROOM SOLID CORE SPECIFICATION STAINLESS STEEL TYPICAL UNLESS OTHERWISE NOTED VERIFY IN FIELD VINYL WALLCOVERING WITH WOOD SIMULATED WOOD PORCELAIN TILE co ' UI2TYEtRD 0 *arriott SUMMARY OF WORK FOR BUILDING DEPARTMENT REVIEW SITEWORK This building is existing. No exterior work on the building is included in this project. Extent of site work to include extension of gas line from exterior wall of fireplace for future optional firepit installation. LOBBY The lobby work consists of removal of existing NON - structural* walls, millwork and wall and floor finishes. New construction to include new floor and wall finishes, new millwork, furnishings and equipment installed throughout the space. Existing ceiling including mechanical, alarm and fire safety devices to remain and ceiling to be painted. Minor ceiling patching and device relocation as needed in areas of demolition. Lighting to remain with exception of several light fixtures replacement with new fixtures of lower wattage. New Lobby areas to include: • Reception with registration millwork to replace existing Front Desk • Market - relocated existing display refrigerator /freezer and replace millwork. • GoBoard /Business Center with new millwork and FF &E to replace existing Business Library • Cafe Dining with new millwork, s- service counter,and FF &E seating • Media Pods with new FF &E seating/TV • Home Theater area with new FF &E seating and TV • Lounge FF &E ELECTRICAL Minor electrical re- location is required as part of the wall relocations. New circuits are added for new service counter equipment. Electrical load of the building remains substantially unchanged. PLUMBING Minor plumbing lines adjustment and extensions as needed per new equipment in service counter area. MEETING ROOMS & BOARD ROOM Meeting rooms to receive new carpet and vinyl wallcovering. Lighting to be replaced with lower wattage fixtures. Alarm /fire safety devices to remain unchanged. EXERCISE ROOM Exercise room to receive new resilient floor covering, new vinyl wallcovering, new TV and new ceiling lights replacement with fixtures of lower wattage. NOTE TO CONTRACTOR PUBLIC HEALTH - SEATTLE & KING COUNTY INSPECTION REQUIRED UPON COMPLETION OF WORK PRIOR TO OPENING. NO CHANGES WILL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL. SYMBOLS LEGEND FINISH TAG REVISION TAG DOOR TAG ACCESSIBLE UNIT HEARING. IMPAIRED UNIT WALL PARTITION TYPE REFER TO SHEET L401 DUPLEX OUTLET SWITCH DATA /PHONE JACK 001 KEYNOTE (ion) n FF &E REFERENCE # x -xxx -- ELEVATION MARK ELEVATION TAG ENLARGED DETAIL MARK SECTION MARK XX' -X" FLOOR SLAB DETAIL NO. DETAIL NO. DETAIL) AREA SHEET NO. DETAIL NO. CODE INFORMATION JURISDICTION: HEALTH DEPARTMENT: BUILDING INFORMATION: BUILDING CODE: Plumbing code: Mechanical code: Electrical code: Accessibility Code: ORIGINAL BUILDING CODE: ORIGINAL BUILDING CONST. TYPE: CURRENT BLDG. CONST. TYPE: USE GROUP: LOBBY RENOVATED AREA (A3): Total Square Footage of Building BLDG. AREAS: OCCUPANCY SEPARATION: MEANS OF EGRESS: FINISHES: No. of Guestrooms Accessible Guestrooms (RIS) VICINITY MAP CITY OF TUKWILA COMMUNITY DEVELOPMENT 6300 SOUTHCENTER BLVD., #100 TUKWILA, WA 98188 PH: 206 -431 -3670 PUBLIC HEALTH SEATTLE & KING COUNTY IBC 2006 UPC 2006 IMC 2006 NEC 2005 / WA STATE ENERGY CODE IBC 2006 Chapter 11; ICC / ANSI 1 -2003 1997 Uniform Building Code w/ WA Amendments TYPE V, 1 hour TYPE VA A -3 / R -1 / B -2 5309 SF 91,534 SF PUBLIC GUEST FIRST FLOOR GUEST SECOND FL. GUEST THIRD FL. TOTAL ALL AREAS 1 HOUR UNMODIFIED BY THE CONSTRUCTION. OCCUPANT LOADS, DIRECTION OF TRAVEL, NUMBER OF EXITS, SEPERATION OF EXITS IS UNCHANGED. REFER TO FINISH INDEX 137 TOTAL 8 TOTAL (2 R.I.S) 13,290 SF 25,492 SF 26,376 SF 26,376 SF 91,534 SF cr to t p dr1 CII I,Nr. r-grr ri LOCATION OF PROJECT A PREOPERATIONAL INSPECTION BY THE KING COUNTY HEALTH DEPARTMENT IS REQUIRED PRIOR TO OPERATION. APPLICANT PLAN SET IS REQUIRED TO BE AVAILABLE O N SITE DURING THAT INSPECTION: INDEX OF DRAWINGS G000 COVER SHEET AND GENERAL NOTES G001 EXISTING SITE PLAN G002 S- SERVICE COUNTER MENUS, INTERIOR GRAPHICS G003 EXISTING KITCHEN G004 MEANS OF EGRESS LOBBY L101 LOBBY DEMOLITION FLOOR PLAN L102 LOBBY REFLECTED CEILING DEMO PLAN L103 LOBBY NEW FLOOR PLAN L104 LOBBY NEW REFLECTED CEILING PLAN L105 LOBBY FLOOR FINISH PLAN L106 LOBBY FURNITURE PLAN L107 NOT USED L108. EXERCISE ROOM L109 MEETING ROOM & CORRIDOR L110 RECEPTION AREA & MARKET ENLARGED PLANS, ELEVS & DETLS L201 LOBBY INTERIOR ELEVATIONS L401 LOBBY PARTITION TYPES, DETAILS & DOOR SCHEDULE L402 LOBBY CEILING DETAILS L403 LOBBY SUNKEN LOUNGE DETAILS 500a WELCOME PEDESTALS DTLS 500b WELCOME PEDESTALS DTLS 501 FOCAL WALL DTLS 502 GOBOARD & COFFEE DTLS G03 NOT USED 504 BUSINESS CENTER & QUICK PRINT DTLS -695— NOT USED 506 THE MARKET SECTIONS 507 MEDIA PODS DTLS 508 COMMUNAL TABLE DTLS. 509a S- SERVICE COUNTER DTLS 509b S- SERVICE COUNTER SECTIONS M.E.P. E000 E001 E100 E200 E201 E210 E300 E400 E500 SHEET INDEX, LEGEND, NOTES LUMINAIRE SCHEDULE, CASEWORK LIGHTING LOBBY PLAN LIGHTING LOBBY PLAN POWER - DEMO LOBBY PLAN POWER - NEW S- SERVICE COUNTER PLAN POWER MEETING ROOM PLANS - LIGHTING / POWER EXERCISE ROOM PLANS - LIGHTING / POWER SPECIFICATIONS P101 S- SERVICE COUNTER PLUMBING P102 LOBBY EXISTING FLOOR PLAN M101 MECHANICAL DEMOLITION FLOOR PLAN M102 MECHANICAL CEILING PLAN M103 PARTIAL EXISTING HVAC PLAN KEY PLAN EXERCISE RM � MEETING ROOMS BOARD RM LOBBY SUBJECT O � AP PROVED SEP 18 2CLT t3y SEATTLE_ ub l SEATTLE-KING Health DIANE AG ASID -6- 2.3 s otel -15� pa. 00(4 14 Re, I 5 I &- 1.1 o3 . REVIEWED FOR CODE COMPLIAN APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVIwIw E N T Li. O r Z L.I. 0< z >- W m Z N W < m CO D 0 U SHEET. 111 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle,, WA 98188 Phone 206.766.8300 Fax 206.766.8080 3380 N REGISTERED A ARCHITECT` 1 REG L. ALLWINE TATE OF WASHINGTON ISSUE /REVISIONS a(Quiuu/ ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 ct w z w 11— U I 0 (1) w J W Cf) N CD co co L co a- Q c � ' J � o D I— PROJECT -FILE 0921.02 0921.02 -G000 DRAWN BY HLB TITLE COVERSHEET AND GENERAL NOTES G000 PROVIDE 111 2:12i SCH 40 CO • I UIT FOR SATELLITE o1B11 NAL W. AU: 'CONDUITS SHOULD E INSt' LLED WITH A PUI L UNE TO FA ATE CABLE INSTALLATION. INSTALL I - a* X 6' TEE hMJ X FL I - 6' GATE VALVE FLX14J EH L.F. 6' D.L 51114•14.V.0. HYDRANT & ACES 2-3I4* . BLOCKING Public Space F.F. ELEV. 26.0 ROM •1 :VI 1 111; 1{.1 an • •1 15' WIDE UTILITY SE7.IENT N OI'05'05' E FOISTING 21' SANITARY SEWER 609.15' ACCESSIBLE PARKING, TYP. 4 emu. CONNECT a•SIDF SERVICE '1'0 E7XISTINL.f• STUB AT.I;LEVATION NO 1i1SiiER THAN 11.43. CONTRAC- TOR STRUCTION 1F LUNIMUM SLOPE OF 2 ' CANNOT BE MAINTAINED. r� • •w. 1• bum IZ' WATER UNE INSTALL' A VALVE (1.1 EXISTING SITE PLAN FOR. INFORMATION ONLY SEE BAR SCALE BELOW R= 410.28' Ly 1210 . L - B7/.115' c o. S 17'52'36'.. 11 BE.99' CONTRACTOR WILL INSTALL HIES LINE BY HORING AND JACIQNG UNDER 8 ACROSS ANDOVER PARK WEST AS a►anww NORTH 1 • 6' GATE VALVE R. X 14J 6 L.F. 6' D.L EXTENSION 5 1t4' 1t.Va7. HYDRANT a AGCES. NJ . 2- 314:.TTE RODS CONC. E3LDCJONG N 1 -8'TEE XF 1 - 6' GATE VALVE FL X MJ 8 L.F. 6' D1 EXTENSION 5 114' M.V.D. HYDRANT & ACGES. 14.1 2 - $14' TIE RODS CONC. BLOCJONG CONC. BLOCIONG 1110111 EXISTING PARKING 165 PARKING SPACES 5 ACCESSIBLE SPACES 170 TOTAL PARKING STALLS NOTE: NO SITE WORK INCLUDED IN SCOPE OF WORK. NOTE CONTRACTOR WILL 12 WATER MAIN AT I$OI RE ALL ST T USE PERMITS ARE INCLUDED WITH IN WATER UNE EXTENSION EAMr CONTRACTOR WILL NOT EXCAVATE OR DISTURB LAND OUTSIDE OF !DOVER PARK WEST RIGHT OF WAY. W CLOSURE OF A LANE IS REQUIRED SANE S HDULD BE "DETCIURED' wHeNtISTAi.L ATIO1i IS COMPLETE CONTRACTOR WILL a� TE AS iERGGU OF T1 J L A . J rf #f, C13MSION y of Tukwila Ti REVIEWED PL NCE COD PROVED OCT 05 2009 RECEIVED SEP 22 2009 PERMIT GENTER OMNI SHEET 111 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 w z w W �� II-o F. 0 zct o < Q u) wm > ° Lll w < � W 0 � DRAWN BY HLB TITLE EXISTING SITE PLAN PROJECT -FILE 0921.02 -G001 -Site Plan G001 ' , „ . • • - • , •• . • , ' Served with coleslaw and choice of kettle chips Half sandwich and soup Choice of tuna or turkey sandwich 9 Natural roast turkey On toasted sourdough, tomato and bacon 9 Tuna salad (Dolphin Safe) On whole grain bread 9 Add a cup of soup To any salad or sandwich 2.5 ri EAT DlliNK CONNECT vegetable sticks or fresh orchard fruit Italian sausage Provolone and peppers on toasted ciabatta 9 Cheddar French dip Shaved roast beef, au jus 9 Toasted three cheese Bacon and tomato 8 Grilled chicken quesadilla Salsa and sour cream 8 Spinach and artichoke quiche With a small tossed salad or fresh fruit 8 "Consuming raw or undercooked meats, poultry, seafood, shellfish or any eggs may increase your risk of foodborne illness." DOOR SIGNS FRONT VIEW 3/16" = 1" WALL SIGNS FRONT VIEW 3/16" — 1" 1100R SIGI1 -- (E111ERED 1111 DOOR 1? ri OPTION A - 2 SIGNS ARE REQUIRED r --- FOR EACII RES WALL SIGN, 1 DOOR SIGN) MEN •.7,1.11! ) 2 typ. / 6 IROM jI 11.01)R 10 SIGNS \ 1111RIIMI1At 1 • - RESTROOM 0002) G002. 12' lj OPTION B WOMEN WALL SIS11 APPLIED 10 Ott 11IF 1,11111 SWF SCALE: NTS PIE 11.419T 7• I_Atct;■ 'I'CANNIAI t 41; n L_1111 , f Arr. ROMARK COPY & BEAD BRAILLE: 311-803A Durk BIOW11 ADAtope Copy is: 7/8" Gotham Rounded, Med Silver Bead (Nine DIGIT: COURFS0171117AJ10.al 12" INTERIOR SIGNAGE OPTION C DOOR SIGHS: M611F .025 Satin Aluminum 011 3/8" Clear Acrylic Size & shape rer drawing & digit JIIU Giain: Horizontal Paint Returns Paint Color: PMS-877-MA Brushed Aluminum Screen Print Symbol Symbol Color:WA-34-1-C Sienna WALL SIGNS: TACF: M611F .025 Solin Aluminum on 3/8" Clem Acrylic 9" x 6" Rectangle Groin: Horizontal Paint Returns Point Color: PMS-877-MA Brushed Aluminum RESTROOM • GRAPH! 311 IPA • winui 11/114SAS 5/211 115 70 1171 • 115•261-6.331irno NW cim JOB NUMBER CLIENT NAME Courtyard 7008 REITRENCE NUMBER RWCAl212 COU DA1E CREATED 08 07-08 kv REVISIONS QUATIEllY DRAWING • =El 111r; l'Aft,Nrj:j • . ; t . THE MARKET PROJECT/LOCA11011 COU 08 /California Standard COMPUTER FILENAME/DIG11 COURES017012A.110.ui DESCRIPTION Califor Ma Standard Men I.D. Sign Set Women I.D. Sign Sel Restroont/Unisex I.D. Sign Sel r,h ,int 1 pmp,ly ■•.1 1'1,411, 01 lot rrl ■Nr;p1 i, to p9'? :4M t,it 701'11,16 ig t1,17Y r,. TYP. SIGN DESIGN STANDARDS j Appletini 7 Mojito 7 Margarita 7 Cosmopolitan 7 Lemon Drop 7 Bloody Mary 7 Vv .\ - ri Beringer White Zinfandel 6 Meridian Pinot Grigio 7 Chateau St. Jean Fume Blanc 9 Clos du Bois Chardonnay 8 Estancia Pinot Noir 9 Columbia Crest Grand Estates Merlot 8 Estancia Cabernet Sauvignon 9 r , j e-`•-■ n . fl„,) Served with a cheese biscuit Broccoli with three cheeses. 5.25 Texas chili Cheddar and sour cream 5.25 \qPf Caesar salad 7 Romaine, parmesan croutons Greek salad 7 Feta, olives, cucumbers and herb vinaigrette Salad add-ons Grilled chicken 3 Cup of soup 2.5 17.7 'N ti )4: - 31\/ Budweiser 4.5 Bud Light 4.5 Miller Lite 4.5 O'Doul's 4.5 "Consuming raw or undercooked meats, poultry, seafood, shellfish or any eggs may increase your risk of foodborne illness." • • • . . • . • . • Blue Moon Belgian White 5 Samuel Adams Boston Lager 5 Sierra Nevada Pale Ale 5 Eggs your way Bacon or sausage, crispy potatoes and toast 9.5 Bacon, cheddar and egg scramble 9 E3utterrnilk blueberry pancakes Maple syrup 8 Spinach and artichoke quiche With fresh fruit 8 E.1 Muffin, bagel, coffee cake, croissant, scone Hot cinnamon bun 3 "Consuming raw or undercooked meats, poultry, ) 1 11 1 Corona Extra 5 Stella Artois Lager 5 Heineken 5 Heineken Premium Light 5 Amstel Light 5 Available Hot or Iced Tazo Chai Latte 3 Tazoa Tea 1.5 ESPRESSO & COFFEE DRINKS Available Hot or Iced Caffe Latte 2.5 Cappuccino 2.5 Caffe Mocha 3 Caramel Macchiato 3 Caffe American° 2 Espresso 1.5 Coffee of the Day 1.5 White Chocolate Mocha 3.5 CreamiceTM Frosted Drinks 3.5 Flavors: Mango, Raspberry, Mocha, Latte t At ; DRuk ,'C131.1N k C • • Buffalo wings, classic or Thai spiced Half dozen with dipping sauce, carrots and celery 8 Chili cheese nachos Salsa and sour cream 6 Chips and salsa 4 Hummus, pita chips and celery 6 , 1'2- :- Sausage, peppers and provolone Feta and olives 8 Tomato and mozzarella 7 served with crispy potatoes or fresh cut fruit Bacon egg and cheddar croissant 7 _ F:: 177,71; ,4\ :7; [1 A N 11 \ Oatmeal, brown sugar and raisins 4 Cereal, banana and milk 4 Granola yogurt parfait 2.5 Fresh cut fruit cup 3 Side bacon 3 One egg 2 seafood, shellfish or any eggs may increase your risk of foodborne illness." • tre Proudly 13reiti sT num:KS COI Breakfast Bur Fried •eggs and crisp bacon with lettuce, tomato and melted cheddar cheese 7 Egg white, roasted turkey Spinacil and havarti on english muffin 7 Egg, green chile and jack cheese Burrito, salsa and sour cream 7 NOTE: MENU BOARDS FOR INFORMATION ONLY- PRICES & REGIONAL SPECIALTIES WILL VARY. R 0 C E I? 0 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION RECEIVED SEP 22 zgog PERMIT GENTEF, Greg L. Allwine ARCHITECT ISSUE/REVISIONS ISSUE TO HPC 08-06-09 MI PROGRESS SET 08-06-09 PERMIT SET 08-12-09 w LL- 0 O r t z a O < z >- w m z Et a w < co ct co D O 0 _I 0 111 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 PROJECT-FILE 0921.02-G002-Menu DRAWN BY HLB TITLE S-SERVICE COUNTER MENUS, GRAPHICS oo co co •tC SHEET G002 DOci 197 EXISTING STORAGE EXISTING HAND SINK . : N . 62 91 5i 97 56 91 • 1 .1CK*VP ' .38 . — 48 r 7 7S 4.7. 2?7 : . /1 • , 143 • • .44 • et •2S ' L <> an 41. 3/ 35 36 IN COCK 1140 31 . PO • I. • • W EXISTING 3-COMPARTMENT SINK W/ 2 DRAIN BOARDS; LOCATION OF EXISTING MOP SINK NEW S-SERVICE COUNTER REF SHEET L301 EXISTING KITCHEN PLAN. G003 NOT TO SCALE NO WORK IN KITCHEN OR BACK OF HOUSE IS INCLUDED IN THIS PROJECT EXISTING KITCHEN PLAN FOR REFERENCE ONLY NOT FOR CONSTRUCTION REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 w LL 0 0 w TITLE City City of Tukwila BUILDING DIVISION RECEIVED SEP 22 2009 sH PERMIT CENTER 6003 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 ISSUE/REVISIONS ISSUE TO HPC 08-06-09 MI PROGRESS SET 08-06-09 PERMIT SET 08-12-09 Phone 206.766.8300 Fax 206.766.8080 z w 0 w PROJECT-FILE 0921.02-G003-Existing Kitchen DRAWN BY EXISTING KITCHEN �EXIT®.� N - EXERCISE ROOM N um m I me N— E— N E w— 0 EXIT r - — 1)09%, i q7 EXIT„ EXIT EXIT EXITING PLAN FOR INFORMATION ONLY REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION RECEIVED SEP 22 2009 PERMIT CENTER N.T.S 111 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT' 3380 E L. ALLWINE TE OF WASHINGTON ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 Ct w F. Z W W U U- o F— o z D 0 u) z >- L1J m w 17; z _J w < 1- ca0 Q . n -e - ca W Q Y o 0 C) CD MEANS OF EGRESS PROJECT -FILE 0921.02 -G004- Exiting Plan DRAWN BY HLB TITLE SHEET G004 EXISTING TO REMAIN FLOOR DEMOLITION KEYNOTES (--) GENERAL DEMOLITION NOTES MARKET EQUIPMENT - TURN OVER TO HOTEL OPERATIONS DOORS AND DOOR HARDWARE U.O.N. FIRE EXTINGUISHER CABINET ALL FIXTURES AND FINISHES TO REMAIN IN EXISTING ACCESSIBLE PUBLIC RESTROOMS. FLOOR REMOVE EXISTING CARPET AND BASE. REMOVE EXISTING TILE FLOOR AND BASE NOT USED TRENCH SLAB FOR POWER, PHONE, DATA & CABLE LINES AS SHOWN ON THE PLAN. COORDINATE W/MILLWORK & FF&E. V.I.F POWER SOURCE LOCATION BEFORE TRENCHING. RE ELECTRICAL. TRENCH SLAB BETWEEN PEDESTAL CHECK-INS TO PROVIDE CONDUIT FOR CONNECTIONS BETWEEN COMPUTERS. V.I.F POWER SOURCE . : . LOCATION BEFORE TRENCHING RE ELECTRICAL 1. 2. 3. 4. 5. 6. DASHED LINES INDICATE CONSTRUCTION TO BE DEMOLISHED. FLOOR AND CEILING PLANS ARE BASED ON EXISTING BUILDING PLANS AND SITE SURVEY. THEY ARE INTENDED TO REASONABLY REPRESENT EXISTING CONDITIONS. GC TO VISIT SITE PRIOR TO CONSTRUCTION FOR VERIFICATION. GC TO FIELD VERIFY WALLS, COLUMNS AND ALL ELEMENTS TO BE DEMOLISHED ARE NON-STRUCTURAL PRIOR TO DEMOLITION. IF WALLS, COLUMNS OR OTHER STRUCTURAL ELEMENTS ARE FOUND WITHIN THE PROPOSED DEMOLITION AREA, OR EXISTING CONDITIONS VARY FROM PLANS, NOTIFY THE PROJECT DIRECTOR BEFORE PROCEEDING. PROTECT EXISTING FINISHES TO REMAIN. DIMENSIONS SHOWN ARE TO FACE OF FINISH U.O.N. WHEN REMOVING EXISTING VWC DO NOT ALLOW PAPER SURFACE OF DRYWALL TO BE TORN. FD1 FD2 FD3 FD4 FD5 WALLS NOT USED. STRUCTURAL COLUMN & GWB TO REMAIN. REMOVE EXISTING FINISHES TO MINIMIZE SIZE OF COLUMN. REMOVE EXISTING WALL SCONCES INCLUDING J-BOX AND WIRING BACK TO SOURCE. REMOVE EXISTING MILLWORK EQUIPMENT WITHIN MILLWORK TO BE TURNED OVER TO HOTEL OPERATIONS U.O.N. REMOVE EXISTING DOOR, FRAME AND THRESHOLD. EXISTING FIREPLACE TO REMAIN. REMOVE SURROUND & PATCH & REPAIR TO RECEIVE NEW FINISHES. REMOVE EXISTING VINYL WALLCOVERING AND WALL WOOD TRIM. REMOVE EXISTING WALL SCONCE EXISTING ELECTRICAL TO REMAIN FOR REUSE. RE ELEC. REMOVE EXISTING WINDOW TREATMENT AND HARDWARE. REMOVE ALL GRAPHICS THROUGHOUT LOBBY, MEETING ROOMS AND EXERCISE ROOM. REMOVE EXISTING NON-STRUCTURAL PARTITION OR PLANTER. PATCH & REPAIR SURROUNDING WALLS. EXISTING STAIR AND RAMP TO REMAIN. REMOVE HANDRAILS AND PREPARE FOR NEW NOT USED. 7. 8. 9. 10. 11. 12. 13. 14. 15. PATCH EXISTING FLOOR, WALL AND CEILING SURFACES IN AREA OF DEMOLITION AS NEEDED TO RECEIVE NEW FINISHES. AFTER REMOVAL OF PLUMBING LINES ETC. FILL ALL OPENINGS IN CONCRETE FLOOR WITH CONCRETE PATCHES. MAINTAIN REQUIRED FIRE EXISTING FIRE ALARM DEVICES AND SPRINKLERS CONFLICTING WITH NEW CONSTRUCTION TO BE RELOCATED BY GC ACCORDING TO GOVE LOCAL CODES. FIRE PROTECTION SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION. ALL LOBBY SERVICES TO REMAIN OPERATIONAL DURING CONSTRUCTION. GC TO COORDINATE WITH PROJECT DIRECTOR AND HOTEL OPERATIONS TEMPORARY LOBBY AREAS OF SERVICE PRIOR TC CONSTRUCTION START, EXISTING CAT, DATA VOICE AND OTHER HOTEL OPERATION SYSTEM CABLES TO REMAIN INTACT DURING CONSTRUCTION. GC TO COORDINATE RELOCATION OF BOXES AND DATA PORTS WITH OWNER'S REPRESENTATIVE PRIOR TO DEMOLITION START. DEMOLITION OF PARTITIONS WITH ELECTRICAL DEVICES TO BE COORDINATED WITH ELECTRICAL CONTRACTOR. ELECTRICAL TERMINATIONS PERFORMED BY ELECTRICAL CONTRACTOR. WHERE EXISTING ELECTRICAL IS PERMANENTLY REMOVED, ALL ASSOCIATED BOXES, DEVICES AND WIRING TO BE REMOVED BACK TO SOURCE REVIEt CODE CC ATING Appr NING OCT City o BUILDIN WD1 WD2 WD3 WD4 WD5 WD6 WD7 WD8 WD9 WD10 WD11 WD12 WD13 TO BE EXISTING CONDUIT THAT IS NOT ACCESSIBLE TO BE ABANDONED AFTER IT IS STRIPPED OF ALL WIRING. REMOVE FF&E U.O.N. REMOVE & RELOCATE EXISTING THERMOSTAT AS NEEDED 1111) %or EXISTING LOUNGE BAR EXISTING FRONT DESK EXISTING BUFFET REMOVE SOFFIT. REMOVE TRIM. REMOVE MILLWORK. R EM OVE NON—STRUCTURAL P AR TI TI ON S. REMOVE STAIRS. REMOVE 2x4 FLUOR. FIXTURE. REMOVE BULKHEAD REMOVE DOOR IN ITS ENTIRETY. PREPARE FOR NEW MARKET CUT OUTS. REMOVE PORTION OF EXISTING WALL FOR NEW MARKET LAYOUT REMOVE EXISTING FRONT DESK, TURN OVER EQUIP TO HOTEL OPERATIONS. REMOVE ARTWORK REMOVE SOFFIT OVER BUFFET. REMOVE ALL BUFFET MILLWORK. NDICATES AREA TO BE REMOVED REMOVE EXG EXHAUST FAN, SWITCH & ACCESS PANEL. REMOVE TIMER SWITCH AT SERVICE BAR KW D NOT IN CONTRACT MEETING RM RELOCATE EXG SPECIALTY POWER RECEPTACLE TV 18" AFF. NOT IN CONTRACT (FD1) FD1 WD7 1 RELOCATE 4 <> EXG WALL 0-1 OUTLETS TO 18" AFF BOARD RM K> <>1 REMOVE BAR INCLUDING MILLWORK, PLUMBING, FIXTURES, GLASS RACKS ETC. WOMEN _11 FD2 WD7 0 0 L WD5 REMOVE DRS, SAVE HARDWARE FOR REUSE. (71 MEN NOT IN CONTRACT LI WD2 WD8 WD4 rr BUFFET FD2/ I WD9 TYP. FD2)-\ FD1 WD7 WD2 = FUTURE FIREPIT LOCATION—COORDINATE WITH PROJECT DIRECTOR. EXTEND & CAP GAS LINE FROM FIREPLACE OUT TO EXTERIOR WALL FOR FUTURE USE OR EXTEND LINE TO OPTIONAL OUTDOOR FIREPIT LOCATION. COORD. W/ PROJECT DIRECTOR, LANDSCAPE DESIGNER & LOCAL CODES. LI WD2 WD8 FD1 FD4 RESTAURANT LI FD4 NOTE: VERIFY IN FIELD EXACT POD PLACEMENT PRIOR TO SLAB TRENCHING. LOUNGE (WD12) n 's> ir-31 WD2 WD 11 WD2 ' l " 11,1 If' FD2 WD1 0 (FD flti / VESTIBULE REMOVE EXG CORNER GUARDS REF: L110 FOR ENLARGED PLANS AND DETAILS // y—(FD4)SFD11 — 13USTNESS 1 LIBRARY I r = = WD11 FD4 FD5 EXG STRUCTURAL]. COLUMN IN WALL] TO IREMAIN.---A -KWD3> r r- —L- E F WD4 1 WD4 FRONT DESK WD5 (WD1 2) WD5 J WD11 ADMIN NOT IN CONTRACT FD2 WD7 f 1 NOT IN CONTRACT LOBBY DEMOLITION FLOOR PLAN SCALE: 1 /8"=.1'-0" 5 2009 ED FOR MPLIANQE OVED Tukwila DIVISION RECEIVED SEP 22 2.003 PEFIMIT GENTEF SHEET Ii 1- F. Li. 0 o w z O < z >- w m z a w < • >- co co D O 0 _1 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 ISSUE/REVISIONS ISSUE TO HPC 08-06-09 MI PROGRESS SET 08-06-09 PERMIT SET 08-12-09 PROJECT-FILE 00992211:0022_1_1w DRAWN BY TITLE LOBBY HLB DEMOLITION FLOOR PLAN L101 EXISTING TO REMAIN CEILING DEMOLITION KEYNOTES O GENERAL DEMOLITION NOTES ACOUSTICAL CEILING U.O.N. SPRINKLERS AND SPRINKLER HEADS U.O.N. RECESSED DOWNLIGHTS U.O.N. EXIT SIGNS RECESSED 2x4 FLUORESCENT LAY -IN FIRE SAFETY AND ALARM DEVICES LIGHT FIXTURES U.O.N. EMERGENCY LIGHTING GWB CEILING AND SOFFITS U.O.N. SPEAKERS GRILLES, REGISTERS AND ACCESS PANELS U.O.N. CEILING 1. - - - DASHED LINES INDICATE CONSTRUCTION TO BE DEMOLISHED. 2. FLOOR AND CEILING PLANS ARE BASED ON EXISTING BUILDING PLANS AND SITE SURVEY. THEY ARE INTENDED TO REASONABLY REPRESENT EXISTING CONDITIONS. GC TO VISIT SITE PRIOR TO CONSTRUCTION FOR VERIFICATION. 3. GC TO FIELD VERIFY WALLS, COLUMNS AND ALL ELEMENTS TO BE DEMOLISHED ARE NON- STRUCTURAL PRIOR TO DEMOLITION. IF WALLS, COLUMNS OR OTHER STRUCTURAL ELEMENTS ARE FOUND WITHIN THE PROPOSED DEMOLITION AREA OR EXISTING CONDITIONS VARY FROM PLANS, NOTIFY THE PROJECT DIRECTOR BEFORE PROCEEDING. 4. PROTECT EXISTING FINISHES TO REMAIN. CD1 SAVE AND PROTECT EXISTING ACT. REPLACE TILES AS NEEDED. CD2 REMOVE EXISTING ACT. CD3 REMOVE EXISTING ACT AS NEEDED TO PREPARE FOR NEW GWB DROPPED CEILING. CD4 REMOVE EXISTING SOFFIT. CD5 REMOVE EXISTING SOFFIT OVER BUFFET INCLUDING RECESSED DOWNLIGHT FIXTURES IN THEIR ENTIRETY. ELECTRICAL CIRCUITS TO BE REALLOCATED FOR NEW BAR LIGHTING AND EQUIPMENT. RE: ELECTRICAL PLANS. CD6 REMOVE EXISTING HVAC DIFFUSER, PREPARE CEILING FOR NEW DIFFUSER SHOWN IN NEW RCP. CD7 RELOCATE EXISTING HVAC DIFFUSER PER RCP ON L104. PAINT TO MATCH ADJACENT FINISH. CD8 REMOVE EXISTING RECESSED DOWNLIGHT FIXTURE. SAVE & RELOCATE ELECTRICAL FOR NEW FIXTURE(S) AS SHOWN IN NEW RCP AND CONNECT TO EXISTING CIRCUIT. RE ELEC. CD9 REMOVE EXISTING DOWNLIGHT. SAVE AND RELOCATE ELECTRICAL TO NEW LOCATION FOR INSTALLATION OF NEW MEDIA POD PENDANT LIGHT FIXTURE. RE ELEC. CD10 REMOVE EXISTING RECESSED DOWNLIGHT IN ITS ENTIRETY INCLUDING J -BOX & WIRING BACK TO SOURCE. RE: ELEC. CD11 REMOVE EXISTING LAY -IN FLUORESCENT LIGHT FIXTURE. SAVE DESIGNATED FIXTURES TO BE RELOCATED. SAVE ELECTRICAL FOR RELOCATION & REUSE. RE: ELEC. CD12 REMOVE EXISTING PENDANT LIGHT. RELOCATE ELECTRICAL AS NEEDED FOR INSTALLATION OF NEW DECORATIVE LIGHT FIXTURE. RE ELEC. CD13 NOTCH SOFFIT AS NEEDED TO ACCOMMODATE NEW S -BAR LATTICE. CD14 REMOVE EXISTING BULKHEAD. 5. DIMENSIONS SHOWN ARE TO FACE OF FINISH U.O.N. 6. WHEN REMOVING EXISTING VWC DO NOT ALLOW PAPER SURFACE OF DRYWALL TO BE TORN. 7. PATCH EXISTING FLOOR, WALL AND CEILING SURFACES IN AREA OF DEMOLITION AS NEEDED TO RECEIVE NEW FINISHES. 8. AFTER REMOVAL OF PLUMBING LINES ETC. FILL ALL OPENINGS IN CONCRETE FLOOR WITH CONCRETE PATCHES. MAINTAIN REQUIRED FIRE RATIN( 9. EXISTING ALARM DEVICES AND SPRINKLERS CONFLICTING WITH NEW CONSTRUCTION TO BE RELOCATED BY GC ACCORDING TO GOVERNING LOCAL CODES. RE CODE Al 0 . C1 BUILT REFLECTED P LAN SYMBOLS 10, FIRE PROTECTION SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION. ALL LOBBY SERVICES TO REMAIN OPERATIONAL DURING CONSTRUCTION. GC TO COORDINATE WITH PROJECT DIRECTOR AND HOTEL OPERATIONS TEMPORARY LOBBY AREAS OF SERVICE PRIOR TO CONSTRUCTION START, 11. EXISTING CAT, DATA VOICE AND OTHER HOTEL OPERATION SYSTEM CABLES TO REMAIN INTACT DURING CONSTRUCTION. GC TO COORDINATE RELOCATION OF BOXES AND DATA PORTS WITH OWNER'S REPRESENTATIVE PRIOR TO DEMOLITION START. 12. DEMOLITION OF PARTITIONS WITH ELECTRICAL DEVICES TO BE COORDINATED WITH ELECTRICAL CONTRACTOR. ELECTRICAL TERMINATIONS TO BE PERFORMED BY ELECTRICAL CONTRACTOR. 13. WHERE EXISTING ELECTRICAL IS PERMANENTLY REMOVED, ALL ASSOCIATED BOXES, DEVICES AND WIRING TO BE REMOVED BACK TO SOURCE. EXISTING CONDUIT THAT IS NOT ACCESSIBLE TO BE ABANDONED AFTER IT IS STRIPPED OF ALL WIRING. 14. REMOVE FF &E U.O.N. 15. REMOVE & RELOCATE EXISTING THERMOSTAT AS NEEDED LAY -IN ACOUSTICAL CEILING TILE &GRID O EXISTING RECESSED o DOWNLIGHT TRACK LIGHTING T -TRACK �/ /� \ HVAC GRILLS & DIFFUSERS (SEE NEW RECESSED DOWNLIGHT TRACK PENDANT MECH. DWGS) 0 -MATCH EXISTING TRIM 4� RELOCATE DIFFUSER Q EXISTING WALL SCONCE TRACK LIGHT HEAD 1 LINEAR DIFFUSER I 1 DECORATIVE PENDANT 2X4 FLUOR. FIXTURE ® DECORATIVE PENDANT R RELOCATE 2X4 FLUOR. FIXTURE LJ CD1 0 O O X X X CD10 ivartak •,/ CD10 CD10 1, Arak,N\ CD9 CD9 CD10 CD8 X 0 1 CD 4 0 CD5) CD8) (12) 0 n 0 (CD10) 0 n n (CD9 CD8 0 0 0 --- �CD10) 0 0 (6) 0 r REMOVE WINDOW TREATMENT ■ j ■ j• & HARDWARE. REPAIR, PATCH & PAINT AS NECESSARY; DO NOT RE- INSTALL. - TYP. CD10 0 ( CD6 (CD10) 0 CD1� REMOVE WINDOW TREATMENTS & HARDWARE. PROTECT DURING CONSTRUCTION. RE- INSTALL ON SOUTH SIDE ONLY: TYP. cps) ( CD1 4 CD1 CD11 (CD8) ( / / \ 11 11 CD7 REFLECTED CEILING DEMO PLAN SCALE: 1 /8"=1'-- 0" DO9' R7 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 SHEET 3380 111 REGISTERED ARCHITECT ISSUE /REVISIONS E� L "INE E OF WASHINGTON ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 w U1 4 W V Z N tL O O z o� O Q 0 f= (f) z w co Q z __I (I) >- W {.L Q O MM D O O i O CO IEWED FOR COMPLIANCE PROJECT -FILE 0921.02 ' PROVED 0921.02 -L 101 T 0 5 2009 DRAWN BY HLB f TITLE of Tukwila LOBBY ING DIVISION REFLECTED CEILING RECEIVED DEMO PLAN SEP 22 26019 PERMIT CENTER L102 EXISTING TO REMAIN NEW WORK KEYNOTES O GENERAL NOTES MARKET EQUIPMENT - TURN OVER TO HOTEL OPERATIONS DOORS AND DOOR HARDWARE U.N.O. EXISTING ACCESSIBLE PUBLIC RESTROOMS TO REMAIN: (EXTENT OF NEW WORK LIMITED TO DOOR REPLACEMENT) FLOOR W9 NEW DECORATIVE WINDOW TREATMENT TO BE FURNISHED BY OWNER AND INSTALLED BY DRAPERY INSTALLER. W10 INSTALL NEW GRAPHICS FURNISHED BY OWNER PER GRAPHICS MANUFACTURER'S DIRECTIONS. REINSTALL EXISTING OCCUPANCY SIGNS AFTER NEW WALL FINISH. W11 FURNISH AND INSTALL NEW FULL - HEIGHT METAL STUD /GWB PARTITION PER PLAN. RE PARTITION TYPES L401. W12 FURNISH AND INSTALL NEW HANDRAILS AT STAIR AND RAMP PER PLANS & ELEVS. REFER TO SHEET L403. W13 FILL IN EXISTING OPENING WITH NEW FRAMING & GWB TO BE FLUSH WITH EXISTING. W14 FURNISH AND INSTALL NEW WOOD BASE AT CARPETED AREA W15 FURNISH AND INSTALL NEW BASE WITH SS FINISH AT MILLWORK & AT WALLS WITH WOOD ACCENT VWC # 324. W16 IN RECEPTION AREA, FURNISH & INSTALL NEW FEATURE WALL WITH MILLWORK CABINETS AND REGISTRATION PEDESTALS . FOR ADDITIONAL INFORMATION RE: L110. W17 FURNISH & INSTALL GOBOARD /COFFEE STATION MILLWORK RE: 502. W18 FURNISH & INSTALL NEW BUSINESS CENTER MILLWORK RE: 504. W19 FURNISH & INSTALL NEW MILLWORK LIBRARY SHELVING IN NEW BUSINESS CENTER AREA RE: 504. W20 INSTALL NEW MDF PANEL WITH DECORATIVE CLOVER IMAGE FURNISHED BY OWNER. W21 FURNISH & INSTALL NEW MILLWORK S -BAR AND EQUIPMENT. RE: 509a,AND MEP SET FOR INFORMATION . W22 FURNISH & INSTALL NEW MILLWORK COMMUNAL TABLE .PROVIDE ELECTRICAL AND DATA CONNECTIONS AS SHOWN ON DETAILS & ELECTRICAL SHEETS. RE: 508 W23 FURNISH & INSTALL NEW FURRED WALL IN HOME THEATER AREA. PROVIDE ELECTRICAL AND CABLE CONNECTIONS- REUSE AND RELOCATE EXISTING AS NEEDED. REFER TO ELEV. B1/L201. W24 FURNISH & INSTALL NEW RECESSED AMENITIES CABINET & MILLWORK RE: L110. W25 NOT USED. W26 IN ADMIN. OFFICES PATCH AND REPAIR FLOORIWALUCEILING SURFACES AS NEEDED IN AREA OF DEMOLITION. INSTALL NEW FINISHES FURNISHED BY OWNER. 1: HATCHED AREAS INDICATE NEW CONSTRUCTION LOW WALL FULL HEIGHT WALL REPRESENT DISSIMILAR FIRE RATING. TO GOVERNING DURING PRIOR TO TO MATCH COLOR F1 INSTALL NEW CARPET AND PAD FURNISHED BY OWNER. RE: L105 F2 FURNISH AND INSTALL NEW PORCELAIN TILE FLOOR AND BASE. RE: L105 F3 NOT USED. F4 RE -FLOAT CONCRETE SLAB AS NEEDED TO ALLOW FOR INSTALLATION OF NEW FLOOR FINISHES OF VARIOUS THICKNESSES. ALL NEW FLOOR FINISH TRANSITIONS TO BE AT UNIFORM LEVEL. F5 FURNISH AND INSTALL NEW SIMULATED WOOD TILE FLOORING . F6 EXTEND PLUMBING LINES TO ACCOMMODATE EQUIPMENT IN NEW S- SERVICE COUNTER. REFER MEP SET FOR INFORMATION. F7 FURNISH & INSTALL TRANSITION STRIP AT DISSIMILAR FLOOR FINISHES. REFER TO L105 FOR DETAILS F8 FURNISH AND INSTALL NEW THRESHOLD WHERE NEW FINISHES ABUT EXISTING FLOORING TO REMAIN. WALLS % / / ////////////4 AND L 2. FLOOR N D CEI ING PLANS ARE BASED ON EXISTING BUILDING PLANS AND SITE SURVEY. THEY ARE INTENDED TO REASONABLY EXISTING CONDITIONS. GC TO VISIT SITE PRIOR TO CONSTRUCTION FOR VERIFICATION. 3. PROTECT EXISTING FINISHES TO REMAIN. 4. DIMENSIONS SHOWN ARE TO FACE OF FINISH U.O.N. 5. WALL SURFACES TO BE PREPARED TO RECEIVE NEW PAINT OR VWC FINISH. FURNISH AND INSTALL SEALANT WHERE NEW VWC ABUTS MATERIALS. DO NOT ALLOW ANY VWC SEAMS WITHIN 6" OF ANY CORNER. 6. PATCH EXISTING FLOOR, WALL AND CEILING SURFACES IN AREA OF DEMOLITION AS NEEDED TO RECEIVE NEW FINISHES. 7. AFTER REMOVAL OF PLUMBING LINES ETC. FILL ALL OPENINGS IN CONCRETE FLOOR WITH CONCRETE PATCHES. MAINTAIN REQUIRED 8. EXISTING FIRE ALARM DEVICES AND SPRINKLERS CONFLICTING WITH NEW CONSTRUCTION TO BE RELOCATED BY GC ACCORDING LOCAL CODES. 9. FIRE PROTECTION SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION. ALL LOBBY SERVICES TO REMAIN OPERATIONAL CONSTRUCTION. GC TO COORDINATE WITH PROJECT DIRECTOR AND HOTEL OPERATIONS TEMPORARY LOBBY AREAS OF SERVICE CONSTRUCTION START, 10. EXISTING CAT, DATA AND VOICE CABLES TO REMAIN INTACT DURING CONSTRUCTION: GC TO COORDINATE RELOCATION OF BOXES AND DATA PORTS WITH OWNER'S REPRESENTATIVE PRIOR TO DEMOLITION START. 11. ALL MULTIPLE SWITCH OR RECEPTACLE LOCATIONS TO BE GANGED AND PROVIDED WITH SINGLE COVER PLATE. COVER PLATES OF DEVICE. EXISTING RECEPTACLES AND SWITCHES TO RECEIVE NEW COVER PLATES. 12. NEW FLOOR AND WALL FINISHES TO EXTEND UNDER OR BEHIND ANY BUILT -IN MILLWORK, EQUIPMENT OR MIRROR. 13. EXISTING AND NEW METAL DOOR FRAMES AND ACCESS PANELS TO BE PAINTED. RE: INTERIOR FINISH INDEX FOR PAINT INFORMATION. 14. INSTALL NEW FF & E PER FURNITURE LAYOUT. RE: L106 W1 FURNISH AND INSTALL NEW METAL STUD /GWB LOW WALL WITH PAINTED WOOD CAP AS SHOWN ON PLAN. RE: L401 FOR PARTITION TYPES. AT EXISTING LOW WALLS REMOVE WOOD CAP, ADJUST HEIGHT & FURNISH & INSTALL NEW WOOD CAP. W2 FURNISH AND INSTALL NEW FINISH TO EXISTING STRUCTURAL COLUMNS. REFER TO ELEVATIONS & INTERIOR FINISH INDEX. W3 STRIP, SAND, PRIME AND PAINT EXISTING STAINED WINDOW SILLS. W4 COORDINATE EXACT LOCATION AND INSTALLATION OF ALL MILLWORK ITEMS WITH PROJECT DIRECTOR. REFER TO MILLWORK DETAILS AND ELECTRICAL PLANS FOR LIGHTING WITHIN MILLWORK. FOR MILLWORK DETAILS RE: 500 -509. W5 NOT USED. W6 FURNISH & INSTALL NEW FIREPLACE SURROUND RE: DETAIL 1/L401. W7 PREPARE SURFACE AND INSTALL NEW VINYL WALLCOVERING PER PLAN AND ELEVATIONS. PROVIDE SEALANT WHERE NEW VINYL ABUTS DISSIMILAR MATERIAL. W8 INSTALL (3) NEW MEDIA PODS COMPLETE WITH OFCI MILLWORK DIVIDER WALL AND OFCI BANQUETTE SEATING IN (3) WINDOW ALCOVES. PROVIDE WITH ELECTRICAL, DATA AND CABLE CONNECTIONS. RELOCATE AND REUSE ELECTRICAL SAVED AFTER WALL SCONCES REMOVAL. RE: 507 15. ALL GWB USED IN THIS PROJECT TO BE 5/8" TYPE X GWB.. BRING EXISTING GWB PARTITIONS IN LOBBY AREA TO A LEVEL 5 FINISF 16. � REFER TO SHEET L401 FOR PARTITION . REVIEWED CODE COMPI AP���I� OCT 052 �� �I TAI BUILDING DI I ^ 1 TYPES. 1) 0 %re 19 .1.1 1 if MEETING RM REF: L109 FOR ENLARGED PLANS & DTLS NOT IN CONTRACT NOT IN CONTRACT F4 F8 /RELOCATE (4) EXG WALL OUTLETS TO 18" AFF BOARD RM 0 WOMEN 0 INSTALL NEW DOORS, REUSE HARDWARE. x 0 MEN NOT IN CONTRACT HOME THEATER YP. YP. Scc ANttit Sbe W2 W21 1 c MILLWORK TABLE (W2 MEDIA PODS (3) D CPT x P (W I MI a F7 I REC P -ION F4 F5 W4 W7 W10 r REPLACE VESTIBULE CORNER GUARDS —TYP. W24 REF: L110 FOR ENLARGED PLANS AND DETAILS QUICK PRINT AREA OF NEW RAISED FLOOR TO BE LEVEL WITH EXISTING LOBBY FLOOR. REF: 1 /L403. F1 W26 ADMIN PAINT ALL DOOR FRAMES IN ADMIN AREA -TYP. SCALE: 1/8" = 1' -0" 0j WA PANE ART AT BOTTOM OF RAMP: 0 NOT IN CONTRACT LOBBY NEW FLOOR PLAN ANCE E0 109 r ila ISIf M Greg L. Allwine ARCHITECT w L � i u- O o- ct z � 0< H z >- \ w co z Li. w / Q M I- W CO D 0 SHEET 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 3380 REGISTERED ARCHITECT` a(Qcvuu/ REG L. ALLWINE TATE OF WASHINGTON ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 w z W I EN- I V (' O D 0 w J (/) W PROJECT -FILE 0921.02 -L101 DRAWN BY HLB TITLE LOBBY NEW FLOOR PLAN O LO L103 EXISTING TO REMAIN NEW WORK KEYNOTES GENERAL NOTES EE EQUIPMENT - TURN OVER TO HOTEL OPERATIONS DOORS AND DOOR HARDWARE U.N.O. EXISTING ACCESSIBLE PUBLIC RESTROOMS TO REMAIN: (EXTENT OF NEW WORK LIMITED TO DOOR REPLACEMENT) FLOOR W9 NEW DECORATIVE WINDOW TREATMENT TO BE FURNISHED BY OWNER AND INSTALLED BY DRAPERY INSTALLER R. W10 INSTALL NEW GRAPHICS FURNISHED BY OWNER PER GRAPHICS MANUFACTURERS DIRECTIONS. REINSTALL EXISTING OCCUPANCY SIGNS AFTER NEW WALL FINISH. W11 FURNISH AND INSTALL NEW FULL - HEIGHT METAL STUD /GWB PARTITION PER PLAN. RE: PARTITION TYPES L401. W12 FURNISH AND INSTALL NEW HANDRAILS AT STAIR AND RAMP PER PLANS & ELEVS. REFER TO SHEET L403. W13 FILL IN EXISTING OPENING WITH NEW FRAMING & GWB TO BE FLUSH WITH EXISTING. W14 FURNISH AND INSTALL NEW WOOD BASE AT CARPETED AREA W15 FURNISH AND INSTALL NEW BASE WITH SS FINISH AT MILLWORK & AT WALLS WITH WOOD ACCENT VWC # 324. W16 IN RECEPTION AREA FURNISH & INSTALL NEW FEATURE WALL WITH MILLWORK CABINETS AND REGISTRATION PEDESTALS . FOR ADDITIONAL INFORMATION RE: L110. W17 FURNISH & INSTALL GOBOARD /COFFEE STATION MILLWORK RE: 502. W18 FURNISH & INSTALL NEW BUSINESS CENTER MILLWORK RE: 504. W19 FURNISH & INSTALL NEW MILLWORK LIBRARY SHELVING IN NEW BUSINESS CENTER AREA RE: 504. W20 INSTALL NEW MDF PANEL WITH DECORATIVE CLOVER IMAGE FURNISHED BY OWNER. W21 FURNISH & INSTALL NEW MILLWORK S-BAR AND EQUIPMENT. RE: 509a,AND MEP SET FOR INFORMATION . W22 FURNISH & INSTALL NEW MILLWORK COMMUNAL TABLE . PROVIDE ELECTRICAL AND DATA CONNECTIONS AS SHOWN ON DETAILS & ELECTRICAL SHEETS. RE: 508 W23 FURNISH & INSTALL NEW FURRED WALL IN HOME THEATER AREA. PROVIDE ELECTRICAL AND CABLE CONNECTIONS- REUSE AND RELOCATE EXISTING AS NEEDED. REFER TO ELEV. B1/L201. W24 FURNISH & INSTALL NEW RECESSED AMENITIES CABINET & MILLWORK RE L110. W25 NOT USED W26 IN ADMIN. OFFICES PATCH AND REPAIR FLOOR/WALUCEILING SURFACES AS NEEDED IN AREA OF DEMOLITION. INSTALL NEW FINISHES FURNISHED BY OWNER. 1. HATCHED AREAS INDICATE NEW CONSTRUCTION 2. FLOOR AND CEILING PLANS ARE BASED ON EXISTING BUILDING PLANS EXISTING CONDITIONS. GC TO VISIT SITE PRIOR TO CONSTRUCTION 3. PROTECT EXISTING FINISHES TO REMAIN. 4. DIMENSIONS SHOWN ARE TO FACE OF FINISH U.O.N. 5. WALL SURFACES TO BE PREPARED TO RECEIVE NEW PAINT OR VWC MATERIALS. DO NOT ALLOW ANY VWC SEAMS WITHIN 6" OF ANY CORNER. 6. PATCH EXISTING FLOOR, WALL AND CEILING SURFACES IN AREA OF 7. AFTER REMOVAL OF PLUMBING LINES ETC. FILL ALL OPENINGS IN CONCRETE 8. EXISTING FIRE ALARM DEVICES AND SPRINKLERS CONFLICTING WITH LOCAL CODES. 9. FIRE PROTECTION SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION. CONSTRUCTION. GC TO COORDINATE WITH PROJECT DIRECTOR AND CONSTRUCTION START, 10. EXISTING CAT, DATA AND VOICE CABLES TO REMAIN INTACT DURING GC TO COORDINATE RELOCATION OF BOXES AND DATA PORTS WITH 11. ALL MULTIPLE SWITCH OR RECEPTACLE LOCATIONS TO BE GANGED OF DEVICE. EXISTING RECEPTACLES AND SWITCHES TO RECEIVE NEW 12. NEW FLOOR AND WALL FINISHES TO EXTEND UNDER OR BEHIND ANY 13. EXISTING AND NEW METAL DOOR FRAMES AND ACCESS PANELS TO 14. INSTALL NEW FF & E PER FURNITURE LAYOUT. RE L106 15. ALL GWB USED IN THIS PROJECT TO BE 5/8" TYPE X GWB.. BRING EXISTING LOW WALL FULL HEIGHT WALL RATING. TO COLOR Fl INSTALL NEW CARPET AND PAD FURNISHED BY OWNER. RE: L105 F2 FURNISH AND INSTALL NEW PORCELAIN TILE FLOOR AND BASE. RE: L105 F3 NOT USED. F4 RE -FLOAT CONCRETE SLAB AS NEEDED TO ALLOW FOR INSTALLATION OF NEW FLOOR FINISHES OF VARIOUS THICKNESSES. ALL NEW FLOOR FINISH TRANSITIONS TO BE AT UNIFORM LEVEL. F5 FURNISH AND INSTALL NEW SIMULATED WOOD TILE FLOORING . F6 EXTEND PLUMBING LINES TO ACCOMMODATE EQUIPMENT IN NEW & SERVICE COUNTER. REFER MEP SET FOR INFORMATION. F7 FURNISH & INSTALL TRANSITION STRIP AT DISSIMILAR FLOOR FINISHES. REFER TO L105 FOR DETAILS F8 FURNISH AND INSTALL NEW THRESHOLD WHERE NEW FINISHES ABUT EXISTING FLOORING TO REMAIN. WALLS AND SITE SURVEY. THEY ARE INTENDED TO REASONABLY REPRESENT FOR VERIFICATION. FINISH. FURNISH AND INSTALL SEALANT WHERE NEW VWC ABUTS DISSIMILAR DEMOLITION AS NEEDED TO RECEIVE NEW FINISHES. FLOOR WITH CONCRETE PATCHES. MAINTAIN REQUIRED FIRE NEW CONSTRUCTION TO BE RELOCATED BY GC ACCORDING TO GOVERNING ALL LOBBY SERVICES TO REMAIN OPERATIONAL DURING HOTEL OPERATIONS TEMPORARY LOBBY AREAS OF SERVICE PRIOR CONSTRUCTION. OWNER'S REPRESENTATIVE PRIOR TO DEMOLITION START. AND PROVIDED WITH SINGLE COVER PLATE. COVER PLATES TO MATCH COVER PLATES. BUILT -IN MILLWORK, EQUIPMENT OR MIRROR. BE PAINTED. RE INTERIOR FINISH INDEX FOR PAINT INFORMATION. GWB PARTITIONS IN LOBBY AREA TO A LEVEL 5 FINISH. RECEI SEP 2 PERMIT GENT& W1 FURNISH AND INSTALL NEW METAL STUD /GWB LOW WALL WITH PAINTED WOOD CAP AS SHOWN ON PLAN. RE L401 FOR PARTITION TYPES. AT EXISTING LOW WALLS REMOVE WOOD CAP, ADJUST HEIGHT & FURNISH & INSTALL NEW WOOD CAP. W2 FURNISH AND INSTALL NEW FINISH TO EXISTING STRUCTURAL COLUMNS. REFER TO ELEVATIONS & INTERIOR FINISH INDEX. W3 STRIP, SAND, PRIME AND PAINT EXISTING STAINED WINDOW SILLS. W4 COORDINATE EXACT LOCATION AND INSTALLATION OF ALL MILLWORK ITEMS WITH PROJECT DIRECTOR. REFER TO MILLWORK DETAILS AND ELECTRICAL PLANS FOR LIGHTING WITHIN MILLWORK. FOR MILLWORK DETAILS RE: 500 -509. W5 NOT USE W6 FURNISH & INSTALL NEW FIREPLACE SURROUND RE: DETAIL 11L401. W7 PREPARE SURFACE AND INSTALL NEW VINYL WALLCOVERING PER PLAN AND ELEVATIONS. PROVIDE SEALANT WHERE NEW VINYL ABUTS DISSIMILAR MATERIAL W8 INSTALL (3) NEW MEDIA PODS COMPLETE WITH OFCI MILLWORK DIVIDER WALL AND OFCI BANQUETTE SEATING IN (3) WINDOW ALCOVES. PROVIDE WITH ELECTRICAL, DATA AND CABLE CONNECTIONS. RELOCATE AND REUSE ELECTRICAL SAVED AFTER WALL SCONCES REMOVAL. RE: 507 REVI CODE C APP OCT C , �, DI� .. 16. REFER TO SHEET L401 FOR PARTITION X TYPES. ` MEETING RM REF: L109 FOR ENLARGED PLANS & DTLS NOT, IN CONTRACT NOT IN CONTRACT BOARD RM a WOMEN 2 INSTALL' NEW DOORS, REUSE F4 HARDWARE. NOT IN CONTRACT LOUNGE W2 W21 MEDIA PODS (3) COFFEE GOBOARD 6'-4" ,. 12' -81 /8 :U NESS CENTER AREA OF NEW RAISED FLOOR TO BE LEVEL WITH EXISTING LOBBY FLOOR. REF: 1/L403. QUICK PRINT sib ADMIN NOT IN CONTRACT i t YP. YP. REPLACE VESTIBULE CORNER GUARDS —TYP REF: L110 FOR ENLARGED PLANS AND DETAILS PAINT ALL DOOR FRAMES IN ADMIN AREA— TYP. LOBBY NEW FLOOR PLAN SCALE: 1/8" = 1' -0" 3380 w E- u 0 o �/ LL. z f O < z >- wm > o z LL. w Q • >" W W D O 0 � U Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT` 'r );,, 41 .. / , , /F�NE OF WASHINGTON ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 w H z w U 2 H 0 cn w J W DRAWN BY HLB TITLE LOBBY NEW OOR PLAN WED FOR R MPLIANCE DVED rn 0 0 w O 0 PROJECT -FILE 0921.02 -L101 5 2009 Tukwila SHEET i DIVISION L 1 03 EXISTING TO REMAIN CEILING KEYNOTES E3 GENERAL NOTES ACOUSTICAL CEILING U.O.N. SPRINKLERS AND SPRINKLER HEADS U.O.N. RECESSED DOWNLIGHTS U.O.N. EXIT SIGNS RECESSED 2 X4 FLUORESCENT LAY -IN LIGHT FIXTURES U.O.N. EMERGENCY EYEBALL FLOOD LIGHTS GWB CEILING AND SOFFITS U.O.N. FIRE SAFETY AND ALARM DEVICES GRILLES, REGISTERS AND ACCESS PANELS U.O.N. SPEAKERS REPAIR ADMIN CEILING AS NEEDED, NO OTHER WORK IN THAT AREA CEILING 1. PATTERNED AREAS INDICATE NEW GWB CEILING CONSTRUCTION. 1., _' ' • . '' J Cl PAINT EXISTING ACT AND GRID AS SPECIFIED IN FINISH INDEX. PAINT ALL PREVIOUSLY PAINTED DEVICES INCLUDING GRILLES, VENTS AND SPEAKER TRIMS TO MATCH NEW COLOR OF CEILING. C2 FURNISH AND INSTALL NEW 2X2 ACT AND GRID PER PLAN AND FINISH INDEX. PAINT NEW ACT, GRID AND ALL PREVIOUSLY PAINTED DEVICES WHERE INDICATED ON PLANS. DO NOT PAINT SPRINKLER HEADS. C3 FURNISH AND INSTALL NEW GWB DROPPED CEILING BELOW EXISTING ACT. REINSTALL AND RECONNECT EXISTING LIGHTING, MEP, ALARM AND SAFETY DEVICES IN SAME LOCATIONS OR NEW LOCATIONS AS REQUIRED PER NEW CEILING CONFIGURATION. C4 FURNISH AND INSTALL NEW GWB CEILING IN AREAS SHOWN. REINSTALL AND RECONNECT EXISTING LIGHTING, MEP, ALARM AND SAFETY DEVICES IN SAME LOCATIONS OR NEW LOCATIONS AS REQUIRED PER NEW CEILING CONFIGURATION. C5 AT S -BAR, MARKET & BUSINESS CENTER, PATCH AND REPAIR CEILING AS NEEDED AFTER SOFFIT REMOVAL. FURNISH AND INSTALL NEW TRACK LIGHTING PER CEILING PLAN, CONNECT TO EXISTING ELECTRICAL CIRCUITS SAVED AFTER CURRENT LIGHTING REMOVAL RE: ELECTRICAL C6 INSTALL NEW LINEAR HVAC DIFFUSER PER PLAN. REFER TO MECHANICAL. C7 RELOCATE EXIST. HVAC DIFFUSER. PAINT TO MATCH ADJACENT FINISH. C8 FURNISH & INSTALL NEW LIGHT FIXTURE AS SHOWN IN RCP PLAN. REFER TO ELECTRICAL FOR FIXTURE INFORMATION. C9 INSTALL NEW DECORATIVE PENDANT LIGHTS FURNISHED BY OWNER OVER THE COMMUNAL TABLE & MEDIA PODS. Cl C10 PATCH & CEILING SURFACES AS NEEDED AFTER DEMOLITION AND PREPARE FOR NEW PAINT FINISH. C11 RELOCATE EXISTING LAY -IN FLUORESCENT LIGHT FIXTURE PER PLAN. C12 PREPARE SURFACE AND PAINT EXISTING AND NEW GWB CEILING SOFFITS BULKHEADS AND SLOPED CEILING. CLEAN & PAINT ALL PREVIOUSLY PAINTED DEVICES INCLUDING GRILLES, VENTS AND SPEAKER TRIMS TO MATCH NEW CEILING COLOR. C13 AT S-BAR AND MARKET FURNISH AND INSTALL NEW WOOD LATTICE FEATURE AS SHOWN ON PLAN RE:11L402. C14 REFER TO MILLWORK DETAILS AND ELECTRICAL PLANS FOR LIGHTING WITHIN NEW MILLWORK. 2. FLOOR AND CEILING PLANS ARE BASED ON EXISTING BUILDING PLANS AND SITE SURVEY. THEY ARE INTENDED TO REASONABLY REPRESENT EXISTING CONDITIONS. GC TO VISIT SITE PRIOR TO CONSTRUCTION FOR VERIFICATION. 3. PROTECT EXISTING FINISHES TO REMAIN. 4. DIMENSIONS SHOWN ARE TO FACE OF FINISH U.O.N. 5. WHEN REMOVING EXISTING VWC DO NOT ALLOW PAPER SURFACE OF DRYWALL TO BE TORN. 6. PATCH EXISTING FLOOR, WALL AND CEILING SURFACES IN AREA OF DEMOLITION AS NEEDED TO RECEIVE NEW FINISHES. 7. AFTER REMOVAL OF PLUMBING LINES ETC. FILL ALL OPENINGS IN CONCRETE FLOOR WITH CONCRETE PATCHES. MAINTAIN REQUIRED FIRE RATING 8. EXISTING FIRE ALARM DEVICES AND SPRINKLERS CONFLICTING WITH NEW CONSTRUCTION TO BE RELOCATED BY GC ACCORDING TO GOVERNING LOCAL CODES. 9. FIRE PROTECTION SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION. ALL LOBBY SERVICES TO REMAIN OPERATIONAL DURING CONSTRUCTION. GC TO COORDINATE WITH PROJECT DIRECTOR AND HOTEL OPERATIONS TEMPORARY LOBBY AREAS OF SERVICE PRIOR TO CONSTRUCTION START, DO NOT PAINT FIRE PROTECTION DEVICES (SPRINKLER HEADS). 10. EXISTING CAT, DATA AND VOICE CABLES TO REMAIN INTACT DURING CONSTRUCTION. GC TO COORDINATE RELOCATION OF BOXES AND DATA PORTS WITH OWNER'S REPRESENTATIVE PRIOR TO DEMOLITION START. 11. DEMOLITION OF PARTITIONS WITH ELECTRICAL DEVICES TO BE COORDINATED WITH ELECTRICAL CONTRACTOR. ELECTRICAL TERMINATIONS TO BE PERFORMED PERFORMED BY ELECTRICAL CONTRACTOR. 12. WHERE EXISTING ONG CCONDUO D IT THAT IS NL E IS NOT ACCESSIBLE T E TO BE ABO REM AFTER AND, ALL ASSOCIATED AFTER IT IS IS STTRIRIPP, DEVICES AND WIRING TO BE REMOVED BACK TO SOURCE. TS STRIPPED OF ALL WIRING. 13. ALL NEW LIGHTING TO BE DIMMABLE (SLIDE RECEPTACLE IS ACCEPTABLE). ALL LIGHTING IN THE FOLLOWING AREAS TO ALSO BE DIMMABLE; S- SERVICE COUNTER, COMMUNAL TABLE, MEDIA PODS, RECEPTION (INCLUDING ENTRY WALKWAY TO GOBOARD). y REFLECTED CEILING PLAN SYMBOLS LAY-IN ACOUSTICAL CEILING TILE & GRID O EXISTING RECESSED DOWNLIGHT e— TRACK LIGHTING T -TRACK HVAC GRILLS & DIFFUSERS SEE O NEW RECESSED DOWNLIGHT TRACK PENDANT X\ MECH. DWGS) -MATCH EXISTING TRIM 4 TRACK LIGHT HEAD RELOCATE DIFFUSER Q EXISTING WALL SCONCE `� LINEAR DIFFUSER I ' I DECORATIVE PENDANT V 009 C1, RG f C ODE Ci APP 2X4 FLUOR. FIXTURE ® DECORATIVE PENDANT R RELOCATE 2X4 FLUOR. FIXTURE LINE OF TABLE L REF: L109 FOR ENLARGED PLANS NOTES AND DETAILS OF TABLE OF WINDOW 409 REF: L110 FOR ENLARGED PLANS AND DETAILS REFERENCE TYPICAL EXISTING CEILING HEIGHTS NOTE: THESE HEIGHTS ARE BASED ON ORIGINAL DRAWINGS & PROVIDED FOR REFERENCE ONLY. VERIFY ACTUAL CONDITIONS. CAFE DINING ACT:1O' -6" t RECEPTION ACT: 8' -O" ± GWB: 9' -O" ± CORRIDOR: 8' -6" ± L104 REFLECTED CEILING PLAN SCALE: 1/8"=1'— 0 OCT 0 5 20U9 City of Tukwila BUILDING DIVISION 3380 w H F- F— u- O O LL. Z O z >- w a w Q M D O O _.a U Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT' /r ALLWINE E OF WASHINGTON ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 Q w z w U H 0 (f) w J W N CO co - co Q - N O o Q Y w o F— a PROJECT -FILE 0921.02 0921.02 -L101 DRAWN BY HLB TITLE LOBBY NEW REFLECTED CEILING PLAN RECEIVED SEP 22 2009 PERMIT CENTEI SHEET L 104 Q ED FOR Q �LIANCE ED NEW KEYNOTES --- FLOOR F1 INSTALL NEW CARPET AND PAD FURNISHED BY OWNER. GENERAL NOTES 1 . DIMENSIONS ARE TO FACE OF FINISH U.N.O. VERIFY HARD SURFACE INSTALLATION DIMENSIONS WITH CARPET SEAMING DIAGRAMS. 2 . ALL TRANSITIONS BETWEEN DISSIMILAR FLOOR TYPES TO RECEIVE SCHLUTER TRANSITION STRIP. RE: TRANSITION DETAILS ON THIS SHEET. 3 . CARPET SEAMING DIAGRAMS TO BE FURNISHED BY CARPET VENDORS. 4. TRANSITIONS BETWEEN NEW AND EXISTING FLOOR FINISHES TO RECEIVE NEW THRESHOLDS OR TRANSITION STRIPS TO MATCH EXISTING. 5 . HATCH PATTERNS IN THIS DRAWING REPRESENT FLOOR FINISHES - NOT INSTALLATION. FULL TILE IS PREFERRED AT ALL TRANSITIONS. NO CUT TILE PIECE SMALLER THAN 6" TO BE USED AT TRANSITIONS. 6. FREE STANDING COLUMNS TO RECEIVE ONE TYPE OF BASE FINISH ON ALL FOUR SIDES. WHERE PORTION OF THE COLUMN ABUTS TILE FLOOR, ALL FOUR SIDES OF THE COLUMN TO RECEIVE TILE BASE. 7 . ADJUST HEIGHT, POSITION & OVERLAP TO CREATE SMOOTH TRANSITIONS BETWEEN DIFFERENT BASE TYPES. MAINTAIN UNIFORM CONSISTENT BASE HEIGHT AND DEPTH AT ALL CORNERS AND TRANSITIONS. ADJACENT FLOOR BASES TO ALIGN WITHOUT NCai .O PLANING.R OTHER ALTERATION. CI ygl(s CODE( API 7 L105 N.T.S. TILE TRANSITION STRIP CPT DIAGRAM 11 CLOVER GRAPHIC ON MDF BACKING. PAINTED WOOD BASE CONTINUE TILE BASE MEETING ROOM 143 MEETING ROOM 143 NOT IN CONTRACT MATCH BASE HEIGHTS, TYP. 1II EX. CPT NOT IN CONTRACT sisisl� ff,!MM■I■Ml■ slsls■ I i • • IMMO 1 MEETING RM J EMPLOYEE DINING I I 1 I I I I I I 1 I I I I I I I I I I I I I I I I I I NEW TILE L105 J SCALE: 3 " =1' -0" 3 3 0 NOT IN CONTRACT CARPET CUSH ION TRANSITION HOME THEATER A I3 I S— COUNTER] • 'E100' - 3/8" STAINLESS STEEL SCHLUTER - SCHIENE TRANSITION STRIP WPT NEW TILE CPT I U L105 J SCALE: 3 " =1' -0" LOUNGE 1 I I I I I I I I I I I I I I I CAFE DINING III IIIIIIIIIII111 MEDIA PODS INSTALL NEW OWNER- FURNISHED CARPET TILE. CENTER CARPET IN VESTIBULE -DO NOT CUT CARPET TILES. TRANSITION NEW WOOD PORCELAIN TILE A I I CPT 1 1 1 1 . 1 1 1 1 I SCALE: 1/8"=1'-0" 4'- 101/2" 'E110' 7/16" STAINLESS STEEL SCHLUTER- SCHIENE TRANSITION STRIP I I 115)I I II I' I I II 1 I I I I I I 115 NOTE: ALL FLOOR FINISHES TO BE INSTALLED AT SAME LEVEL. ALL TRANSITIONS BETWEEN DISSIMILAR FINISHES TO BE FLUSH WITH NO CHANGE IN LEVEL. SCALE: 3 " =1' -0" BUSINESS CENTER s _•i MI MUM I MEWL sss■ lir 111.111M ! • NEW WOOD PORCELAIN TILE TRANSITION 1 I I I 1 11 I I 1 1 I 1 1 1 I I 1 I I I I I I I I I I 1 1 1 I I I I I I I I 1 1 1 I 1 1 I I N T I I ..J SI .I 1 1 1 1 I I LOBBY FLOOR FINISH PLAN NOT IN CONTRACT T 'El 10' - 7/16" STAINLESS STEEL SCHLUTER - SCHIENE TRANSITION STRIP /./ CARPET FLEX CUSHION NOT IN CONTRACT b09% EX. CPT *IN ADMIN OFFICES PATCH & REPAIR FLOOR SURFACES AS NEEDED IN AREA OF DEMOLITION AND INSTALL NEW CARPET & PAD FURNISHED BY OWNER. r OCT 0 5 2009 City of Tukwila BUILDING DIVISION Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT r / •,fir Inr4-4 1F ,; + ��rr L. ALLWINE E OF WASHINGTON 3380 ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 w _ F F- 0 o- E z a 0< z >- wcc) Z � wQ >- W L.6. CO 0 U (1) Et"' w H z w 0 Z 0 w J H H W PROJECT —FILE 0921.02— L105 —FFP DRAWN BY HLB TITLE LOBBY FLOOR FINISH PLAN RECEIVED SEP 22 2009 PERMIT CENTER' SHEET CO WED FOR L105 OMPLIAMV ROVED BDR -500 BOARD RM PR -500 PR -501 LM -208 LM -213L — LM -600 LM -600M HOME THEATER EXIST LM -403 LM- 217 -39R V - 303 WD ACCENT VWC, TYP. LM -500 LM -860 LM- 602(2) \� LM- 602M(2) LM-205L-ALTERNATE-3-SEAT LM -803 GC MLWK LM- 404(2) LM -806 LM -402 LM -212 0 LM -218 LM -805 LM -206 -210 (2) LM LM -805 (2) WPT,CPT LM -219 LM -220 LM -221 LM -001 CPT LM -003 PAD LM -403 LM -216AR LM -804 (2) LOUNGE LM -002 CPT LM -003 PAD LM- 202(4) CAFE DINING LM- 200(12) LM- 201(8) L MEDI� PODS LM -230 LM -205L LM -205L LM- 204(3) LM -100 LM- 401(3) TYP. WINDOW TREATMENT LM -215 -T LM -223 (3) LM -227 LM -805 LM LM RECEPTION LOUNGE LM- 215 -39 LM- 205ML(3 LM- 219(3) LM- 207 - 43(4) LM- 207 -86 CPT,, PT LM- 207 -660TT LM -206 LM -210 - LM -89.5 LM -219 LM -220 LM -221 COFFEE STATION w C.) VESTIBULE GO -BOARD LIBRARY SHELVING LM -813 LM -814 GC MLWK WPT RECEPTION GC MLWK LM -811 LM -812 LM -815 LM -819 LM -208 LM -822 LM -211 V -303 WD ACCENT VWC, AMENITIES CABINET MARKET GRAPHICS TERRACE FURNITURE: (1) TE -205 DINING TABLE (4) TE -208 DINING CHAIR (1) TE -203 SOFA (4) TE -207 END TABLE (2) TE -204 COFFEE TABLE (7) TE -201 CHAIR (1) TE -215 UMBRELLA LAPTOP PORT LM -800 LM -807 REFER TO SHT 504 FOR LM -808 ARTIFACT PLACEMENT LM -809 BUSINESS CENTER LM -002 CPT LM -003 PAD V -303 WD ACCENT VWC,TYP. QUICK PRINT LM -801 - LM- 214(3) - LM- 215 -39 - LM -215 -T V -301 —� LM -803 TYP. WINDOW TREATMENT LM -100 LM -100 GAS LINE TO FUTURE OUTDOOR FIRE PIT LM -100 EXIST LOBBY FURNITURE PLAN LDING DI S IIa IBN SCALE: 1/4"=V-0" NOTE: APPROVED LAYOUT ISSUED TO HATCH PURCHASING 8 -06 -2009 REVISED APPROVED LAYOUT RE- ISSUED TO HATCH PURCHASING 8 -11 -2009 W _ H u O o r Z 0< F z >- UJ co z Q co> L.L. m � 0 0 U DRAWN BY TITLE RECEIVED SEP 22 2039 PERMIT CENTEF SHEET Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 3380 REGISTERED ARCHITECT G . ALLWINE E OF WASHINGTON ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 ct w z w U F : 0 (i) w J F- F- w (/) Mrs PROJECT -FILE 0921.02 0921.02 -L106 HLB LOBBY FURNITURE PLAN L106 BRUSHED NICKEL LAMINATE BASE t, PULLS: EPCO, DP41 —A-3" 1 1/ 4 "x8" FINISHED CUTOUT, W/ STAINLESS STEEL LINER WASTE RECEPTACLE, NIC BRUSHED NICKE LAMINATE BAS 0 , EQ EQ EQ\ (3) 1/4" GLASS MIRROR PANELS, BY G.C. BLOCKING AS REQ'D O SCALE: 1/4 " =1' -0" O O W43 0 1' -O" SECTION SCALE: 1 1/2"=1'-0" SCALE: 1 1/2 " =1' -0" E O 1 /2" PANEL WITH „„/ BRUSHED NICKEL O LAMINATE ° O O SECTION 0 5' -0" 1 1/2" D40 RECESS FOR HEADPHONES — 3/4" ADJUSTABLE SHELF ON PINS Sc BUSHINGS PLYWOOD \--(WD4C 216) 2X SOLID WOOD TRIM, STAIN 1/4" SAFETY MIRROR EXERCISE RM #81314" PAN SCREWS L108 L108 6' -9" EXG PTAC W49 387 ART 2' -0" SECTION SCALE: 1-1/2"=1'-0" NOT USED NOT USED RE- 500ALT 1 -HR FIRE RATED STAIR ENCLOSURE WALL STAIRS RETAIN RATING OF 1 -HR FIRE PROTECTED WALL IF ADDING BLOCKING FOR MIRROR ATTACHMENT, TYP. EXISTING TO REMAIN ACT GRID AND CEILING TILES GRILLES, REGISTERS AND ACCESS PANELS U.O.N. SPRINKLERS AND SPRINKLER HEADS U.O.N. FIRE SAFETY AND ALARM DEVICES HOUSE PHONE RCP SYMBOLS QR 2x FLUOR. FIXTURE WALL MOUNTED DECORATIVE FIXTURE RELOCATED EXISTING LIGHT FIXTURE 0 RECESSED FIXTURE Qi PIN SPOT SURFACE MOUNTED LIGHT FIXTURE '-Q WALL SCONCE O SPEAKER ® SMOKE DETECTOR V Z EXIT LIGHT X IMINE ■-. CEILING MOUNTED SPRINKLER HEAD VERIFY IN FIELD HVAC GRILLS & DIFFUSERS (SEE MECH. DWGS) RELOCATE EXISTING HVAC LAY -IN ACOUSTICAL CEILING TILE & GRID CD1 EXERCISE ROOM RCP L108 SCALE: 1/4 " =1' -0" \—(vvo ELEVATION SCALE: 1/4"=1'-0" RE— INSTALL NEW FIXTURES IN EXG LOCATIONS. LINEN/ TRASH W/ CUBBIES LINEN/ TRASH W/ CUBBIES RE -600 RE— 600AL W49 EXG PTAC TO REMAIN; : ADJUST EQUIPMENT AS NEEDED REINSTALL EXISTING REINSTALL EXISTING MIRROR SUPPORTS SCALE: 1/4"=1'-0" GENERAL NOTES 1. DASHED LINES INDICATE CONSTRUCTION TO BE DEMOLISHED 2. FLOOR AND CEILING PLANS ARE BASED ON EXISTING BUILDING PLANS AND SITE SURVEY. THEY ARE INTENDED TO REASONABLY REPRESENT EXISTING CONDITIONS. GC TO VISIT SITE PRIOR TO CONSTRUCTION FOR VERIFICATION. 3. PROTECT EXISTING FINISHES TO REMAIN. 4. DIMENSIONS SHOWN ARE TO FACE OF FINISH U.O.N. 5. WHEN REMOVING EXISTING VWC DO NOT ALLOW PAPER SURFACE OF DRYWALL TO BE TORN. WALL SURFACE TO BE PREPARED TO RECEIVE NEW PAINT OR VWC FINISH. FURNISH AND INSTALL SEALANT WHERE VWC ABUTS DISSIMILAR MATERIAL. DO NOT ALLOW ANY VWC SEAMS WITHIN 6" OF ANY CORNER. 6. PATCH EXISTING FLOOR, WALL AND CEILING SURFACES IN AREA OF DEMOLITION AS NEEDED TO RECEIVE NEW FINISHES. 7. AFTER REMOVAL OF PLUMBING LINES ETC. FILL ALL OPENINGS IN CONCRETE FLOOR WITH CONCRETE PATCHES. MAINTAIN REQUIRED FIRE RATING. 8. EXISTING FIRE ALARM DEVICES AND SPRINKLERS CONFLICTING WITH NEW CONSTRUCTION TO BE RELOCATED BY GC ACCORDING TO GOVERNING LOCAL CODES. 9. FIRE PROTECTION SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION. ALL LOBBY SERVICES TO REMAIN OPERATIONAL DURING CONSTRUCTION. GC TO COORDINATE WITH PROJECT DIRECTOR AND HOTEL OPERATIONS TEMPORARY LOBBY AREAS OF SERVICE PRIOR TO CONSTRUCTION START, 10, EXISTING CAT, DATA AND VOICE CABLES TO REMAIN INTACT DURING CONSTRUCTION. GC TO COORDINATE RELOCATION OF BOXES AND DATA PORTS WITH OWNER'S REPRESENTATIVE PRIOR TO DEMOLITION START. 11. DEMOLITION OF PARTITIONS WITH ELECTRICAL DEVICES TO BE COORDINATED WITH ELECTRICAL CONTRACTOR. ELECTRICAL TERMINATIONS TO BE PERFORMED BY ELECTRICAL CONTRACTOR. 12. WHERE EXISTING ELECTRICAL IS PERMANENTLY REMOVED, ALL ASSOCIATED BOXES, DEVICES AND WIRING TO BE REMOVED BACK TO SOURCE. EXISTING CONDUIT THAT IS NOT ACCESSIBLE TO BE ABANDONED AFTER IT IS STRIPPED OF ALL WIRING. 13. REMOVE FF &E UNLESS OTHERWISE NOTED. WATER COOLER ELEVATION L10) SCALE: 1/4" =1' -0" 4ND41) (W41) RE -700 DIGITAL CLOCK DIGITAL CLOCK MFR: BRG PRECISION PRODUCT, INC. Contact: Rich Meyer 800 - 295 - 0220x230 RMeyer(a,BRGproducts.com MODEL: #AC20- 01 -10 -01 R -TS 2" RED 'LED' DIGITS (TOGGLE BETWEEN TIME AND TEMPERATURE) PROVIDE LANDSCAPE ELECTRICAL OUTLET AT INSTALLATION HEIGHT NOT RECESSED. RECESSED CLOCK BACK WILL COVER. THE OUTLET. REMOTE TEMPERATURE SENSOR INCLUDED. PROVIDE FULLY CONCEALED ELECTRICAL WIRING AND MOUNT SENSOR TO THE CEILING SURFACE. A . REINSTALL EXISTING RE- 500ALT ART PANEL INSTALL CONCEALED WATER SUPPLY LINE BEHIND WALL, INSTALL OWNER- FURNISHED WATER COOLER. W44)LINEN /TRASH W/ INTEGRATED TOWEL CUBBIES; RE: 7 & 8/L108 EXERCISE ROOM FLOOR PLAN EXERCISE RM �� MEETING ROOMS BOARD RM O " " LOBBY KEY PLAN SCALE: 1/64 " =1' -0" DEMO (D. FLOOR FD1 REMOVE EXISTING CARPET AND BASE. WALLS WD7 REMOVE EXISTING VINYL WALLCOVERING & WALL WOOD TRIM. WD10 REMOVE ALL GRAPHICS THROUGHOUT LOBBY, MEETING ROOMS AND EXERCISE ROOM. WD13 REMOVE EXISTING WALL MIRROR, PATCH & REPAIR SURFACE TO RECEIVE NEW FINISHES. WD41 REMOVE EXISTING WALL MOUNTED CLOCK AND ELECTRICAL. CEILING CD1 SAVE AND PROTECT EXISTING ACT. REPLACE TILES AS NEEDED. CD40 REMOVE EXISTING LIGHT FIXTURES. NEW KEYNOTES ED FLOOR F8 F40 WALLS W7 CEILING FURNISH AND INSTALL NEW THRESHOLD WHERE NEW FINISHES ABUT EXISTING FLOORING TO REMAIN. PREPARE SURFACE AND INSTALL NEW RUBBER FLOOR IN PATTERN SHOWN ON PLAN. PREPARE SURFACE AND INSTALL NEW VINYL WALLCOVERING PER PLAN AND ELEVATIONS. PROVIDE SEALANT WHERE NEW VINYL ABUTS DISSIMILAR MATERIAL. W10 INSTALL NEW GRAPHICS FURNISHED BY OWNER PER GRAPHICS MANUFACTURER'S DIRECTIONS. W40 FURNISH AND INSTALL NEW RUBBER BASE. W41 PROVIDE ELECTRICAL IN NEW CLOCK LOCATION AND INSTALL NEW DIGITAL CLOCK AS SHOWN ON ELEVATION. W42 INSTALL OWNER FURNISHED DECORATIVE PANEL USING 3/4" STAND -OFFS AND CAPS BETWEEN WALL AND PANEL. W43 FURNISH & INSTALL NEW MIRROR PANELS. INSTALL WITH OWNER- FURNISHED HORIZONTAL WOOD FRAMING RE: 31L108. W44 INSTALL WALL MOUNTED MILLWORK CUBBY AND TOWEL TRASH CABINET FURNISHED BY OWNER AS SHOWN ON PLANS. W45 MODIFY EXISTING ELECTRICAL TO PROVIDE NECESSARY WIRING, J -BOXES /ELECTRICAL, CABLE/TV FOR EQUIPMENT LAYOUT. COORDINATE REQUIREMENTS WITH EQUIPMENT SPECIFICATIONS. W46 INSTALL OWNER FURNISHED EXERCISE EQUIPMENT AS SHOWN ON PLAN. W49 PROVIDE NECESSARY WIRING FOR ELECTRICAL OUTLET AND CABLE TV JUNCTION BOX FOR NEW OWNER FURNISHED TV. C40 FURNISH & INSTALL NEW FLUORESCENT LIGHT FIXTURES . MODIFY ELECTRICAL AS REQ'D FOR NEW LIGHTING PLAN. CONNECT TO NEW SWITCH WITH MOTION SENSOR. RE: ELECTRICAL REVIEWED FOR CODE COMPLIANC APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISIO RECEIVED SEP 22 2009 PERMIT CENTEE oq Lq1 Greg L. Allwine ARCHITECT SHEET 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT" T ee EG L. ALLWINE E OF WASHINGTON 3380 ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 • C2 w z w U 2 F- O (/) w 1-- H W (f) DRAWN BY HLB TITLE EXERCISE ROOM PROJECT -FILE 0921.02- L108 -C- Exercise RM L108 EXISTING TO REMAIN GENERAL NOTES AND BASE. WALLCOVERING AND WALL WOOD TREATMENT AND HARDWARE. THROUGHOUT LOBBY, MEETING ROOMS OCCUPANCY SIGNS TO BE REPLACED OF 49. COUNTERTOP & BACKSPLASH. IN STORAGE CLOSET TO REMAIN. & REPAIR WALL & CEILING TO TV. PATCH & REPAIR WALL & CEILING LIGHT FIXTURES. SAVE ELECTRICAL IN SOFFITS TO REMAIN. HOUSE PHONE THERMOSTAT ELECTRICAL AND CONTROLS PLATE WITH & PHONE RECEPTACLES, SWITCHES, REPLACE EACH DEVICE COVER FIRE PROTECTION SYSTEM INCLUDING SPRINKLERS, EXIT & EMERGENCY LIGHTING, ALARMS ETC. CEILING U.O.N WINDOW CORNICES AND PROJECTOR SCREEN CORNICE 1. - - - DASHED LINES INDICATE CONSTRUCTION TO BE DEMOLISHED. 2. FLOOR AND CEILING PLANS ARE BASED ON EXISTING BUILDING PLANS AND SITE SURVEY. THEY ARE INTENDED TO REASONABLY REPRESENT EXISTING CONDITIONS. GC TO VISIT SITE PRIOR TO CONSTRUCTION FOR VERIFICATION. 3. PROTECT EXISTING FINISHES TO REMAIN. 4. DIMENSIONS SHOWN ARE TO FACE OF FINISH U.O.N. 5. WHEN REMOVING EXISTING VWC DO NOT ALLOW PAPER SURFACE OF DRYWALL TO BE TORN. AFTER NEW VWC INSTALLATION IS COMPLETE, FURNISH AND INSTALL SEALANT WHERE VWC ABUTS DISSIMILAR MATERIAL. 6. PATCH EXISTING FLOOR, WALL AND CEILING SURFACES IN AREA OF DEMOLITION AS NEEDED TO RECEIVE NEW FINISHES. 9. FIRE PROTECTION SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION. 10, EXISTING CAT, DATA AND VOICE CABLES TO REMAIN INTACT DURING CONSTRUCTION. GC TO COORDINATE RELOCATION OF BOXES AND DATA PORTS WITH OWNER'S REPRESENTATIVE PRIOR TO DEMOLITION START. 12. WHERE EXISTING ELECTRICAL IS PERMANENTLY REMOVED, ALL ASSOCIATED BOXES, DEVICES AND WIRING TO BE REMOVED BACK TO SOURCE. EXISTING CONDUIT THAT IS NOT ACCESSIBLE TO BE ABANDONED AFTER IT IS STRIPPED OF ALL WIRING. 13. REMOVE FF &E U.O.N. NEW - COVER PLATE COLOR TO MATCH COLOR OF DEVICE - RELOCATE SPECIALTY POWER SWITCH RECEPTACLE TO 18" AFF (SEE PHOTO A.1); REMOVE TIMER SWITCH AT BAR (SEE PHOTO A.2), PATCH & REPAIR WALLS TO MATCH ADJ FINISHES. REFLECTED PLAN SYMBOLS C12 PREPARE SURFACE AND CEILING, SOFFITS, BULKHEADS PAINT ALL PREVIOUSLY VENTS AND SPEAKER TRIMS C50 FURNISH AND INSTALL NEW FIXTURES PER RCP. CONNECT CIRCUIT AND SWITCH. qb 0 .... 9 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION 2x4 FLUOR. FIXTURE 1- 0 WALL MOUNTED DECORATIVE FIXTURE OS RELOCTED EXISTING LIGHT FIXTURE ® RECESSED FIXTURE PIN SPOT SURFACE MOUNTED LIGHT FIXTURE WALL SCONCE SPEAKER SMOKE DETECTOR CEILING MOUNTED SPRINKLER HEAD MOUNTED SPRINKLER HEAD EXIT LIGHT HVAC GRILLS & DIFFUSERS (SEE MECH. DWGS) RELOCATE EXISTING HVAC LAY -IN ACOUSTICAL CEILING TILE & GRID `� � / I I 0 0 Q " Mill 's' min DEMO KEYNOTES C FLOOR AND BASE. WALLCOVERING AND WALL WOOD TREATMENT AND HARDWARE. THROUGHOUT LOBBY, MEETING ROOMS OCCUPANCY SIGNS TO BE REPLACED OF 49. COUNTERTOP & BACKSPLASH. IN STORAGE CLOSET TO REMAIN. & REPAIR WALL & CEILING TO TV. PATCH & REPAIR WALL & CEILING LIGHT FIXTURES. SAVE ELECTRICAL IN SOFFITS TO REMAIN. FD1 REMOVE EXISTING CARPET WALLS WD7 REMOVE EXISTING VINYL TRIM. WD9 REMOVE EXISTING WINDOW WD10 REMOVE ALL GRAPHICS AND EXERCISE ROOM. WITH OCCUPANCY LOAD WD54 REMOVE EXISTING CABINET. WD55 REMOVE EXISTING PLAM WD57 EXISTING WALL CARPET WD58 REMOVE EXISTING ARTWORK. WD59 . REMOVE VALANCES. PATCH RECEIVE NEW FINISHES. WD60 REMOVE WALL - MOUNTED TO RECEIVE NEW FINISHES. CEILING CD50 REMOVE EXISTING 2X4 FOR NEW FIXTURES. CD51 EXISTING RECESSED DOWNLIGHTS PROTECT DURING CONSTRUCTION. NEW KEYNOTES C FLOOR AND PAD FURNISHED BY OWNER. RE: L105 TILE FLOORING 2' -0" WIDE ALONG CABINET. INSTALL NEW VINYL WALLCOVERING PROVIDE SEALANT WHERE NEW MATERIAL. TREATMENT TO BE FURNISHED BY BY DRAPERY INSTALLER. FURNISHED BY OWNER PER GRAPHICS REINSTALL EXISTING NEW WALL FINISH. CABINET PER PLAN & ELEVATION. STONE COUNTERTOP & BACKSPLASH FURNISHED BY OWNER. INSIDE STORAGE CLOSETS. FURNISHED BY OWNER. COORDINATE REPRESENTATIVE. PAINT EXISTING AND NEW GWB AND SLOPED CEILING. CLEAN & PAINTED DEVICES INCLUDING GRILLES, TO MATCH NEW CEILING COLOR. 2X4 SURFACE MOUNTED LIGHT TO EXISTING ELECTRICAL F1 INSTALL NEW CARPET F2 FURNISH & INSTALL NEW ENTIRE LENGTH OF BASE WALLS W7 PREPARE SURFACE AND PER PLAN AND ELEVATIONS. VINYL ABUTS DISSIMILAR W9 NEW DECORATIVE WINDOW OWNER AND INSTALLED W10 INSTALL NEW GRAPHICS MANUFACTURER'S DIRECTIONS. OCCUPANCY SIGNS AFTER W54 FURNISH AND INSTALL NEW W55 FURNISH & INSTALL NEW PER FINISH INDEX. W56 INSTALL NEW CARPET BASE W57 PAINT WALLS AND CEILING W58 INSTALL NEW ARTWORK INSTALLATION WITH MI CEILING C12 PREPARE SURFACE AND CEILING, SOFFITS, BULKHEADS PAINT ALL PREVIOUSLY VENTS AND SPEAKER TRIMS C50 FURNISH AND INSTALL NEW FIXTURES PER RCP. CONNECT CIRCUIT AND SWITCH. qb 0 .... 9 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION RECEIVED SEP 22 2009 PERMIT CENTER 1 9 7 TYP.@ DR.FRAMES 334 PNT (307) P.LAM DR.FRAMES 334) PNT (309 PNT EXG PTAC H P �309) N B 409 PNT w \_ ART EXG PROJECTION SCREEN TO REMAIN (334 PNT ART \ART MR -504 MR -505 "- MR -506 MEETING ROOM SCALE: 1/4"=1'-0" SCALE: 1/4 " =1' -0" SCALE: 1/4 " =1' -0" 329 VWC 205 CPT(w56, EXISTING WALL SCONCE TO REMAIN, TYP. (WD7 MEETING ROOM MEETING ROOM — EXISTING WALL SCONCE TO REMAIN, TYP. VWC (WD7, PNT 309 (wD7) REMOVE EXG EXHAUST FAN, SWITCH & ACCESS PANEL. PATCH & REPAIR TO MATCH SURROUNDING FINISHES. SEE PHOTOS A.2, A.3 304 VWC EXG ' TAG 409 PNT EXG PTAC 309 PNT (3 GRANITE CPT .LAM PNT ART MR -500 MR -501 L MR -502 409 (329) PNT VWC MR -507 ART S.S. EXG PROJECTION SCREEN TO REMAIN ART (W56 ART 329 VWC 20� CPT <322) P.LAM (329) VWC PNT ,r F L109 D MEETING ROOM 1 / — EXISTING WALL SCONCE TO REMAIN, TYP. 304 L109 SCALE: 1/4 " =1' -0 334. WD7 CORRIDOR SCALE: 1/4"=1'-0" 30 P.LAM VWC SEE PHOTO A.1 MEETING ROOM SCALE: 1/4"=V-0" G PTAC TYP. DR. FRA ES PNT P.L 307 WD7) 309 PNT PNT L -109 D54. W54 D55 W55 MR -100 MR -101 MR -507 MR -200 (30) -., 0- L-109 MR -100 MR -101 L -109 MR -507, MR -200 (30) - a A.3 MR -100 MR -101 REFLECTED CEILING PLAN L109 W57 FURNISH & INSTALL NEW ENTRY D b5• , CLOSET DOORS & HARD � ARE PER SPECS; REPAI T DOOR FRAMES, FLOOR PLAN �9 SCALE: NTS SCALE: 1/8 " =1' -0" A.2 A.1 EXG PHOTOS rWD9 W9 EXERCISE RM SCALE: 1/64 " =1' -0" KEY PLAN MR -100 MR -101 M YAM 11111 Oct pAncy 60 MEETING ROOMS BOARD RM Greg L. A Twine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 ISSUE /REVISIONS w H LL O_ O z L.I. 0< z >- wm z w L Q H m m D 0 O w z w U 2 H 0 cn w J F- -F-- w ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 PROJECT -FILE 0921.02-L1 09-C-Meeting RM DRAWN BY HLB TITLE MEETING ROOMS PLAN, RCP ELEVATIONS SHEET L109 '' ci 1. v , „, Ate ,, � � � ,∎A ,� , > „)- DEMO KEYNOTES C FLOOR FD1 REMOVE EXISTING CARPET AND BASE. FD2 REMOVE EXISTING TILE FLOOR AND BASE. FD3 IN DESIGNATED AREAS STRIP SURFACE OF CONCRETE SLAB AS NEEDED FOR INSTALLATION OF WOOD FLOORING. RE:L105 FD4 TRENCH SLAB FOR POWER, PHONE, DATA & CABLE LINES AS SHOWN ON THE PLAN. COORDINATE W /MILLWORK & FF &E. V.I.F POWER SOURCE LOCATION BEFORE TRENCHING. RE ELEC. FD5 TRENCH SLAB BETWEEN PEDESTAL CHECK -INS TO PROVIDE CONDUIT FOR CONNECTIONS BETWEEN COMPUTERS. V.I.F POWER SOURCE LOCATION BEFORE TRENCHING. RE: ELEC. WALLS WD3 REMOVE EXISTING WALL SCONCES INCLUDING J -BOX AND WIRING BACK TO SOURCE. WD4 REMOVE EXISTING MILLWORK. EQUIPMENT WITHIN MILLWORK TO BE TURNED OVER TO HOTEL OPERATIONS U.O.N. WD5 REMOVE EXISTING DOOR, FRAME AND THRESHOLD. WD7 REMOVE EXIST. VINYL WALLCOVERING AND WALL WOOD TRIM. WD8 REMOVE EXISTING WALL SCONCE. EXISTING ELECTRICAL TO REMAIN FOR REUSE. RE: ELEC. WD10 REMOVE ALL GRAPHICS THROUGHOUT LOBBY, MEETING ROOMS AND EXERCISE ROOM. OCCUPANCY SIGNS TO REMAIN, SAVE FOR REINSTALLATION. WD11 REMOVE EXISTING NON- STRUCTURAL PARTITION OR PLANTER. PATCH & REPAIR SURROUNDING WALLS. CEILING CD1 SAVE AND PROTECT EXISTING ACT. REPLACE TILES AS NEEDED. CD2 REMOVE EXISTING ACT. SEE L104 FOR NEW CEILING. CD6 REMOVE EXISTING HVAC DIFFUSER, PREPARE CEILING FOR NEW DIFFUSER SHOWN IN NEW RCP. CD7 RELOCATE EXISTING HVAC DIFFUSER PER RCP ON L104. PAINT TO MATCH ADJACENT FINISH. CD8 REMOVE EXISTING RECESSED DOWNLIGHT FIXTURE. SAVE & RELOCATE ELECTRICAL FOR NEW FIXTURE(S) AS SHOWN IN NEW RCP AND CONNECT TO EXISTING CIRCUIT. RE: ELEC. CD11 REMOVE EXISTING LAY -IN FLUORESCENT LIGHT FIXTURE. SAVE DESIGNATED FIXTURES TO BE RELOCATED. SAVE ELECTRICAL FOR RELOCATION & REUSE. RE: ELEC. CD14 REMOVE EXISTING BULKHEAD. NEW KEYNOTES n FLOOR F2 FURNISH AND INSTALL NEW PORCELAIN TILE FLOOR AND BASE. RE: L105 F3 FURNISH AND INSTALL NEW WOOD FLOORING. FOLLOW FLOORING MANUFACTURER'S DIRECTIONS FOR INSTALLATION OVER CONCRETE SUBFLOOR. F4 RE -FLOAT CONCRETE SLAB AS NEEDED TO ALLOW FOR INSTALLATION OF NEW FLOOR FINISHES OF VARIOUS THICKNESSES. ALL NEW FLOOR FINISH TRANSITIONS TO BE AT UNIFORM LEVEL. F7 FURNISH & INSTALL TRANSITION STRIP AT DISSIMILAR FLOOR FINISHES. REFER TO L105 FOR DETAILS WALLS Ilk otilailt I (":\>:,` � ;? , ; ? ''y \ > „ I I W4 COORDINATE EXACT LOCATION AND INSTALLATION OF ALL 1 9 MILLWORK ITEMS WITH PROJECT DIRECTOR. REFER TO MILLWORK DETAILS AND ELECTRICAL PLANS FOR LIGHTING WITHIN MILLWORK. FOR MILLWORK DETAILS RE: 500 -509 W7 PREPARE SURFACE AND INSTALL NEW VINYL WALLCOVERING PER PLAN AND ELEVATIONS. PROVIDE SEALANT WHERE NEW VINYL ABUTS DISSIMILAR MATERIAL. W10 INSTALL NEW GRAPHICS FURNISHED BY. OWNER PER GRAPHICS MANUFACTURER'S DIRECTIONS. REINSTALL EXISTING OCCUPANCY SIGNS AFTER NEW WALL FINISH. WI1 FURNISH AND INSTALL NEW FULL - HEIGHT METAL STUD/GWB PARTITION PER PLAN. RE: PARTITION TYPES L401. W13 FILL IN EXISTING OPENING WITH NEW FRAMING & GWB TO BE FLUSH WITH EXISTING. W15 FURNISH AND INSTALL NEW BASE WITH SS FINISH AT MILLWORK & AT WALLS WITH WOOD ACCENT VWC # 324. W16 IN RECEPTION AREA, FURNISH & INSTALL NEW FEATURE WALL WITH MILLWORK CABINETS AND REGISTRATION PEDESTALS . FOR ADDITIONAL INFORMATION RE: L110. W24 FURNISH & INSTALL NEW RECESSED AMENITIES CABINET & MILLWORK RE: L110. W25 GC TO FURNISH & INSTALL NEW SOLID SURFACE COUNTERTOPS FOR OWNER- FURNISHED MILLWORK ITEMS INCLUDING WELCOME PEDESTALS AND COMMUNAL TABLE RE: 500a, 508. W26 IN ADMIN. OFFICES PATCH AND REPAIR FLOORIWALLICEILING SURFACES AS NEEDED IN AREA OF DEMOLITION. INSTALL NEW FINISHES FURNISHED BY OWNER. CEILING C1 PAINT EXISTING ACT AND GRID AS SPECIFIED IN FINISH INDEX. PAINT ALL PREVIOUSLY PAINTED DEVICES INCLUDING GRILLES, VENTS AND SPEAKER TRIMS TO MATCH NEW COLOR OF CEILING. C2 FURNISH AND INSTALL NEW 2X2 ACT AND GRID PER PLAN AND FINISH INDEX. PAINT NEW ACT, GRID AND ALL PREVIOUSLY PAINTED DEVICES WHERE INDICATED ON PLANS. C4 FURNISH AND INSTALL NEW GWB CEILING IN AREAS SHOWN. REINSTALL AND RECONNECT EXISTING LIGHTING, MEP, ALARM AND SAFETY DEVICES IN SAME LOCATIONS OR NEW LOCATIONS AS REQUIRED PER NEW CEILING CONFIGURATION. C5 AT S -BAR, MARKET & BUSINESS CENTER, PATCH AND REPAIR CEILING AS NEEDED AFTER SOFFIT REMOVAL. FURNISH AND INSTALL NEW TRACK LIGHTING PER CEILING PLAN, CONNECT TO EXISTING ELECTRICAL CIRCUITS SAVED AFTER CURRENT LIGHTING REMOVAL RE: ELECTRICAL C6 INSTALL NEW LINEAR HVAC DIFFUSER PER PLAN. REFER TO MECHANICAL. C7 RELOCATE EXISTING HVAC DIFFUSER. PAINT TO MATCH ADJACENT FINISH. C8 FURNISH & INSTALL NEW LIGHT FIXTURE AS SHOWN IN CLNG PLAN. REFER TO ELECTRICAL FOR FIXTURE INFORMATION. C10 PATCH & REPAIR CEILING SURFACES AS NEEDED AFTER DEMOLITION AND PREPARE FOR NEW PAINT FINISH. C11 RELOCATE EXISTING LAY -IN FLUORESCENT LIGHT FIXTURE PER PLAN. C12 PREPARE SURFACE AND PAINT EXISTING AND NEW GWB CEILING, SOFFITS, BULKHEADS AND SLOPED CEILING. C14 REFER TO MILLWORK DETAILS AND ELECTRICAL PLANS FOR LIGHTING WITHIN NEW MILLWORK. '' ci 1. v , „, Ate ,, � � � ,∎A ,� , > „)- 316 I L 0 0 i Ilk otilailt I (":\>:,` � ;? , ; ? ''y \ > „ I I OPEN RKET TO / \ 1 9 316 I L hT4 1( .!1 U IJ I ` EXISTING FRONT DESK CEILING EXISTING FRONT DESK ELEVATION ELEVATION SCALE: 1/4"=1'-0" OPEN TO CORRIDOR BEYOND EXISTING ANNUNCIATOR FIRE SYSTEM PANEL TO REMAIN INDICATES AREA TO BE REMOVED 409 GWB DROP- CLNG I ELEVATION D ELEV SCALE: 1/4"=V-0" LOW WALL / / / / / // / / / / / / //. 0 C4 AT 8' -0" A.F.F.' f 210 RECEPTION �K ELEVATION L110 SCALE: 1/4 " =1' -0 SCALE: 1/4"=1'-0" FULL HEIGHT WALL 40 WELCOME PEDESTALS 5 SCALE: 1/4"=1'-0" 1. HATCHED AREAS INDICATE NEW CONSTRUCTION 2. FLOOR AND CEILING PLANS ARE BASED ON EXISTING BUILDING PLANS AND SITE SURVEY. THEY ARE INTENDED TO REASONABLY REPRESENT EXISTING CONDITIONS. GC TO VISIT SITE PRIOR TO CONSTRUCTION FOR VERIFICATION. 3. GC TO FIELD VERIFY WALLS, COLUMNS AND ALL ELEMENTS TO BE DEMOLISHED ARE NON- STRUCTURAL PRIOR TO DEMOLITION. IF WALLS, COLUMNS OR OTHER STRUCTURAL ELEMENTS ARE FOUND WITHIN THE PROPOSED DEMOLITION AREA, OR EXISTING CONDITIONS VARY FROM PLANS, NOTIFY THE PROJECT DIRECTOR BEFORE PROCEEDING. 4. DIMENSIONS SHOWN ARE TO FACE OF FINISH U.O.N. 5. WALL SURFACES TO BE PREPARED TO RECEIVE NEW PAINT OF VWC FINISH. FURNISH AND INSTALL SEALANT WHERE NEW VWC ABUTS DISSIMILAR MATERIALS. DO NOT ALLOW ANY VWC SEAMS WITHIN 6" OF ANY CORNER. 6. WHEN REMOVING EXISTING VWC DO NOT ALLOW PAPER SURFACE OF DRYWALL TO BE TORN. 7. PATCH EXISTING FLOOR, WALL AND CEILING SURFACES IN AREA OF DEMOLITION AS NEEDED TO RECEIVE NEW FINISHES. 1 5' -1" L 1 •1 r --210 K ci 4 (40p INSTALL NEW WOOD TRELLIS, NOTCH TO ALLOW FOR CEILING MOUNTED TRACK LIGHTING, RE: 5/402 FOR MOUNTING DETAIL NEW REFLECTED. CEILING PLAN ELE AT ON 324 17" FLAT PANEL SECURITY MONITOR, PROVIDED BY OWNER. EXISTING ANNUNCIATOR FIRE SYSTEM PANEL TO REMAIN. T -STAT RELOCATED TO INSIDE OF COVE. NEW ANNUNCIATOR MAP, PROVIDED BY OWNER B L110 ELEVATION SCALE: 1/4"=1-0" APPROX. 19x19 REMOVABLE PANEL AT CABINET BASE FOR IEE ACCESS TO ELECTRICAL / DATA /PHONE / AND HOTEL t- OPERATION SYSTEMS 12" x 12" GRID FOR MILLWORK POSITIONING -- -- -- -- -- -- -- - -w�.. 2 "CLR 2' -7 $" QUICK PRINT MARKET r- V.I.F. L110 I 2' -0 j V.I.F. ELEVATION SCALE: 1/4"=1-0" 4' -1" VIF 2' -10" 0 NEW FLOOR PLAN SCALE 1/4"=1'-0" L 11 L1 ADD DECORATIVE FILM TO EXISTING EQUIP. 10. EXISTING CAT, DATA AND VOICE CABLES TO REMAIN INTACT DURING CONSTRUCTION. GC TO COORDINATE RELOCATION OF BOXES AND DATA PORTS WITH OWNER'S REPRESENTATIVE PRIOR TO DEMOLITION START. 12. ALL MULTIPLE SWITCH OR RECEPTACLE LOCATIONS TO BE GANGED AND PROVIDED WITH SINGLE COVER PLATE. COVER PLATES TO MATCH COLOR OF DEVICE. EXISTING RECEPTACLES AND SWITCHES TO RECEIVE NEW COVER PLATES. 13. NEW FLOOR AND WALL FINISHES TO EXTEND UNDER OR BEHIND ANY BUILT -IN MILLWORK, EQUIPMENT OR MIRROR. 14. EXISTING AND NEW METAL DOOR FRAMES AND ACCESS PANELS TO BE PAINTED. RE INTERIOR FINISH INDEX FOR PAINT INFORMATION. 15. FOR RCP LEGEND, SEE SHEET L104 L110 ELEVATION A ELEV SCALE: 1/4"=V-0" 8. EXISTING FIRE ALARM DEVICES AND SPRINKLERS CONFLICTING WITH NEW CONSTRUCTION TO BE RELOCATED BY GC ACCORDING TO LOCAL CODES. CONFIRM WITH FIRE DEPARTMENT 9. FIRE PROTECTION SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION. ALL LOBBY SERVICES TO REMAIN OPERATIONAL DURING CONSTRUCTION. GC TO COORDINATE WITH PROJECT DIRECTOR AND HOTEL OPERATIONS TEMPORARY LOBBY AREAS OF SERVICE PRIOR TO CONSTRUCTION START. GENERAL NOTES REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION KEY PLAN SCALE: 1 /64 " =1' -0" RECEIVED SEP 22 2009 PEWIT CENTER RECEPTION & MARKET 1)403'• 1 c? 3380 ISSUE /REVISIONS Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT` 4 ' : . ALLWINE TE OF WASHINGTON y ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 SHEET W 1. I l-- u- O O Z LL. 0< Z }- LLU cc) > W Q co ct co 0 (/) w z w U 2 H 0 c� w J F- F- w DRAWN BY HLB /ET TITLE RECEPTION & MARKET AREA PLAN, RCP ELEVATIONS CO CO CO F— PROJECT-FILE 0921.02- L110 -C- Reception- Market L110 400 Andover Park West PROJECT # 0921.02 L 0 0 i Ilk otilailt I� III ii �� EXISTING FRONT DESK CEILING EXISTING FRONT DESK ELEVATION ELEVATION SCALE: 1/4"=1'-0" OPEN TO CORRIDOR BEYOND EXISTING ANNUNCIATOR FIRE SYSTEM PANEL TO REMAIN INDICATES AREA TO BE REMOVED 409 GWB DROP- CLNG I ELEVATION D ELEV SCALE: 1/4"=V-0" LOW WALL / / / / / // / / / / / / //. 0 C4 AT 8' -0" A.F.F.' f 210 RECEPTION �K ELEVATION L110 SCALE: 1/4 " =1' -0 SCALE: 1/4"=1'-0" FULL HEIGHT WALL 40 WELCOME PEDESTALS 5 SCALE: 1/4"=1'-0" 1. HATCHED AREAS INDICATE NEW CONSTRUCTION 2. FLOOR AND CEILING PLANS ARE BASED ON EXISTING BUILDING PLANS AND SITE SURVEY. THEY ARE INTENDED TO REASONABLY REPRESENT EXISTING CONDITIONS. GC TO VISIT SITE PRIOR TO CONSTRUCTION FOR VERIFICATION. 3. GC TO FIELD VERIFY WALLS, COLUMNS AND ALL ELEMENTS TO BE DEMOLISHED ARE NON- STRUCTURAL PRIOR TO DEMOLITION. IF WALLS, COLUMNS OR OTHER STRUCTURAL ELEMENTS ARE FOUND WITHIN THE PROPOSED DEMOLITION AREA, OR EXISTING CONDITIONS VARY FROM PLANS, NOTIFY THE PROJECT DIRECTOR BEFORE PROCEEDING. 4. DIMENSIONS SHOWN ARE TO FACE OF FINISH U.O.N. 5. WALL SURFACES TO BE PREPARED TO RECEIVE NEW PAINT OF VWC FINISH. FURNISH AND INSTALL SEALANT WHERE NEW VWC ABUTS DISSIMILAR MATERIALS. DO NOT ALLOW ANY VWC SEAMS WITHIN 6" OF ANY CORNER. 6. WHEN REMOVING EXISTING VWC DO NOT ALLOW PAPER SURFACE OF DRYWALL TO BE TORN. 7. PATCH EXISTING FLOOR, WALL AND CEILING SURFACES IN AREA OF DEMOLITION AS NEEDED TO RECEIVE NEW FINISHES. 1 5' -1" L 1 •1 r --210 K ci 4 (40p INSTALL NEW WOOD TRELLIS, NOTCH TO ALLOW FOR CEILING MOUNTED TRACK LIGHTING, RE: 5/402 FOR MOUNTING DETAIL NEW REFLECTED. CEILING PLAN ELE AT ON 324 17" FLAT PANEL SECURITY MONITOR, PROVIDED BY OWNER. EXISTING ANNUNCIATOR FIRE SYSTEM PANEL TO REMAIN. T -STAT RELOCATED TO INSIDE OF COVE. NEW ANNUNCIATOR MAP, PROVIDED BY OWNER B L110 ELEVATION SCALE: 1/4"=1-0" APPROX. 19x19 REMOVABLE PANEL AT CABINET BASE FOR IEE ACCESS TO ELECTRICAL / DATA /PHONE / AND HOTEL t- OPERATION SYSTEMS 12" x 12" GRID FOR MILLWORK POSITIONING -- -- -- -- -- -- -- - -w�.. 2 "CLR 2' -7 $" QUICK PRINT MARKET r- V.I.F. L110 I 2' -0 j V.I.F. ELEVATION SCALE: 1/4"=1-0" 4' -1" VIF 2' -10" 0 NEW FLOOR PLAN SCALE 1/4"=1'-0" L 11 L1 ADD DECORATIVE FILM TO EXISTING EQUIP. 10. EXISTING CAT, DATA AND VOICE CABLES TO REMAIN INTACT DURING CONSTRUCTION. GC TO COORDINATE RELOCATION OF BOXES AND DATA PORTS WITH OWNER'S REPRESENTATIVE PRIOR TO DEMOLITION START. 12. ALL MULTIPLE SWITCH OR RECEPTACLE LOCATIONS TO BE GANGED AND PROVIDED WITH SINGLE COVER PLATE. COVER PLATES TO MATCH COLOR OF DEVICE. EXISTING RECEPTACLES AND SWITCHES TO RECEIVE NEW COVER PLATES. 13. NEW FLOOR AND WALL FINISHES TO EXTEND UNDER OR BEHIND ANY BUILT -IN MILLWORK, EQUIPMENT OR MIRROR. 14. EXISTING AND NEW METAL DOOR FRAMES AND ACCESS PANELS TO BE PAINTED. RE INTERIOR FINISH INDEX FOR PAINT INFORMATION. 15. FOR RCP LEGEND, SEE SHEET L104 L110 ELEVATION A ELEV SCALE: 1/4"=V-0" 8. EXISTING FIRE ALARM DEVICES AND SPRINKLERS CONFLICTING WITH NEW CONSTRUCTION TO BE RELOCATED BY GC ACCORDING TO LOCAL CODES. CONFIRM WITH FIRE DEPARTMENT 9. FIRE PROTECTION SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION. ALL LOBBY SERVICES TO REMAIN OPERATIONAL DURING CONSTRUCTION. GC TO COORDINATE WITH PROJECT DIRECTOR AND HOTEL OPERATIONS TEMPORARY LOBBY AREAS OF SERVICE PRIOR TO CONSTRUCTION START. GENERAL NOTES REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION KEY PLAN SCALE: 1 /64 " =1' -0" RECEIVED SEP 22 2009 PEWIT CENTER RECEPTION & MARKET 1)403'• 1 c? 3380 ISSUE /REVISIONS Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT` 4 ' : . ALLWINE TE OF WASHINGTON y ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 SHEET W 1. I l-- u- O O Z LL. 0< Z }- LLU cc) > W Q co ct co 0 (/) w z w U 2 H 0 c� w J F- F- w DRAWN BY HLB /ET TITLE RECEPTION & MARKET AREA PLAN, RCP ELEVATIONS CO CO CO F— PROJECT-FILE 0921.02- L110 -C- Reception- Market L110 400 Andover Park West PROJECT # 0921.02 L 0 0 i I� III ii �� EXISTING FRONT DESK CEILING EXISTING FRONT DESK ELEVATION ELEVATION SCALE: 1/4"=1'-0" OPEN TO CORRIDOR BEYOND EXISTING ANNUNCIATOR FIRE SYSTEM PANEL TO REMAIN INDICATES AREA TO BE REMOVED 409 GWB DROP- CLNG I ELEVATION D ELEV SCALE: 1/4"=V-0" LOW WALL / / / / / // / / / / / / //. 0 C4 AT 8' -0" A.F.F.' f 210 RECEPTION �K ELEVATION L110 SCALE: 1/4 " =1' -0 SCALE: 1/4"=1'-0" FULL HEIGHT WALL 40 WELCOME PEDESTALS 5 SCALE: 1/4"=1'-0" 1. HATCHED AREAS INDICATE NEW CONSTRUCTION 2. FLOOR AND CEILING PLANS ARE BASED ON EXISTING BUILDING PLANS AND SITE SURVEY. THEY ARE INTENDED TO REASONABLY REPRESENT EXISTING CONDITIONS. GC TO VISIT SITE PRIOR TO CONSTRUCTION FOR VERIFICATION. 3. GC TO FIELD VERIFY WALLS, COLUMNS AND ALL ELEMENTS TO BE DEMOLISHED ARE NON- STRUCTURAL PRIOR TO DEMOLITION. IF WALLS, COLUMNS OR OTHER STRUCTURAL ELEMENTS ARE FOUND WITHIN THE PROPOSED DEMOLITION AREA, OR EXISTING CONDITIONS VARY FROM PLANS, NOTIFY THE PROJECT DIRECTOR BEFORE PROCEEDING. 4. DIMENSIONS SHOWN ARE TO FACE OF FINISH U.O.N. 5. WALL SURFACES TO BE PREPARED TO RECEIVE NEW PAINT OF VWC FINISH. FURNISH AND INSTALL SEALANT WHERE NEW VWC ABUTS DISSIMILAR MATERIALS. DO NOT ALLOW ANY VWC SEAMS WITHIN 6" OF ANY CORNER. 6. WHEN REMOVING EXISTING VWC DO NOT ALLOW PAPER SURFACE OF DRYWALL TO BE TORN. 7. PATCH EXISTING FLOOR, WALL AND CEILING SURFACES IN AREA OF DEMOLITION AS NEEDED TO RECEIVE NEW FINISHES. 1 5' -1" L 1 •1 r --210 K ci 4 (40p INSTALL NEW WOOD TRELLIS, NOTCH TO ALLOW FOR CEILING MOUNTED TRACK LIGHTING, RE: 5/402 FOR MOUNTING DETAIL NEW REFLECTED. CEILING PLAN ELE AT ON 324 17" FLAT PANEL SECURITY MONITOR, PROVIDED BY OWNER. EXISTING ANNUNCIATOR FIRE SYSTEM PANEL TO REMAIN. T -STAT RELOCATED TO INSIDE OF COVE. NEW ANNUNCIATOR MAP, PROVIDED BY OWNER B L110 ELEVATION SCALE: 1/4"=1-0" APPROX. 19x19 REMOVABLE PANEL AT CABINET BASE FOR IEE ACCESS TO ELECTRICAL / DATA /PHONE / AND HOTEL t- OPERATION SYSTEMS 12" x 12" GRID FOR MILLWORK POSITIONING -- -- -- -- -- -- -- - -w�.. 2 "CLR 2' -7 $" QUICK PRINT MARKET r- V.I.F. L110 I 2' -0 j V.I.F. ELEVATION SCALE: 1/4"=1-0" 4' -1" VIF 2' -10" 0 NEW FLOOR PLAN SCALE 1/4"=1'-0" L 11 L1 ADD DECORATIVE FILM TO EXISTING EQUIP. 10. EXISTING CAT, DATA AND VOICE CABLES TO REMAIN INTACT DURING CONSTRUCTION. GC TO COORDINATE RELOCATION OF BOXES AND DATA PORTS WITH OWNER'S REPRESENTATIVE PRIOR TO DEMOLITION START. 12. ALL MULTIPLE SWITCH OR RECEPTACLE LOCATIONS TO BE GANGED AND PROVIDED WITH SINGLE COVER PLATE. COVER PLATES TO MATCH COLOR OF DEVICE. EXISTING RECEPTACLES AND SWITCHES TO RECEIVE NEW COVER PLATES. 13. NEW FLOOR AND WALL FINISHES TO EXTEND UNDER OR BEHIND ANY BUILT -IN MILLWORK, EQUIPMENT OR MIRROR. 14. EXISTING AND NEW METAL DOOR FRAMES AND ACCESS PANELS TO BE PAINTED. RE INTERIOR FINISH INDEX FOR PAINT INFORMATION. 15. FOR RCP LEGEND, SEE SHEET L104 L110 ELEVATION A ELEV SCALE: 1/4"=V-0" 8. EXISTING FIRE ALARM DEVICES AND SPRINKLERS CONFLICTING WITH NEW CONSTRUCTION TO BE RELOCATED BY GC ACCORDING TO LOCAL CODES. CONFIRM WITH FIRE DEPARTMENT 9. FIRE PROTECTION SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION. ALL LOBBY SERVICES TO REMAIN OPERATIONAL DURING CONSTRUCTION. GC TO COORDINATE WITH PROJECT DIRECTOR AND HOTEL OPERATIONS TEMPORARY LOBBY AREAS OF SERVICE PRIOR TO CONSTRUCTION START. GENERAL NOTES REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION KEY PLAN SCALE: 1 /64 " =1' -0" RECEIVED SEP 22 2009 PEWIT CENTER RECEPTION & MARKET 1)403'• 1 c? 3380 ISSUE /REVISIONS Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT` 4 ' : . ALLWINE TE OF WASHINGTON y ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 SHEET W 1. I l-- u- O O Z LL. 0< Z }- LLU cc) > W Q co ct co 0 (/) w z w U 2 H 0 c� w J F- F- w DRAWN BY HLB /ET TITLE RECEPTION & MARKET AREA PLAN, RCP ELEVATIONS CO CO CO F— PROJECT-FILE 0921.02- L110 -C- Reception- Market L110 400 Andover Park West PROJECT # 0921.02 EXG DOOR TO REMAIN H ART RELOCATED OUTLETS AT BOARD ROOM 18" AFF; KEEP IN LINE WITH EXG LOCATIONS— VERIFY IN FIELD ELEVATION SCALE: 1/4"=1'-0" BOARD RM OPEN TO RESTROOM ALCOVE EXTEND HANDRAIL 1 FT HORIZONTALLY PAST BOTTOM OF RAMP EXG WALL SCONCES [-- TO REMAIN --TYP. I PUBLIC RESTROOM ELEVATION L201 SCALE: 1/4 "=1 , ° \ � > , OPEN IL GWB BUILD -OUT — FURNISH & INSTALL EXTRA LAYER OF GWB AT CORRIDOR FACE OF ACCENT VINYL P L_ VIF 4' -0" MARKET REFER TO SHEET L110 FOR MARKET ELEVS \\ HOME THEATER E 4 "CLOVER" PHOTO MURAL -I_ I EXTEND HANDRAIL 1 FT HORIZONTALLY PAST TOP OF RAMP. AT CORNER CONDITION, WRAP HANDRAIL AROUND CORNER FOR 1 FT TOTAL EXTENSION. V GWB CLOUD 409 SEE SHEET L402 (30) r 324 ;Y7 309 LL L Lt) STAIRS FURNISH & INSTALL NEW HANDRAILS, REFER TO DETAIL 1/L403 LOUNGE I 509a 1 I 1 r I I LT S.S. COLUMN COVER 410 ACT REFER TO MEP FOR ADDITIONAL S- SERVICE COUNTER INFO 3/4" MDF WITH CLOVER IMAGE VENEER BUSINESS CENTER 300 ACT pumniuglipm I t 204) GOBOARD �.� - - I 1 I I I I i L201 ` - -MOO LOW WALL WITH NEW (HORIZONTAL STRIPE) VWC & 3/4" HARDWOOD CAP W/1/4" REVEAL RE: S /L401 S- SERVICE COUNTER LT 409 GWB CLOUD S.S. SEE SHEET L104 COLUMN COVER MEDIA PODS ELEVATION SCALE: 1/4"=1'-0" i. rr:silrL I B ELEVATION `201 SCALE: 1/4 " =1' -0" GWB 40‘' DROP r CLNG v\, 1 OPEN TO CORRIDO EYON 209 RECEPTION TRACK LIGHTING SYSTEM- SEE RCP PLAN L104 FURNISH & INSTALL NEW HANDRAILS, REFER TO DETAIL 1/L403 409 I i 324 I 300 HOME THEATER X204 EXISTING RAMP DOWN WOOD SILL TO REMAIN, PAINT (316) WALL BEYOND B1 L201 SHEET NOTES NOTE: #300 VINYL WALLCOVERING TO BE INSTALLED HORIZONTALLY. REFER TO INTERIOR FINISH INDEX FOR VINYL WALLCOVERING INSTALLATION & SPECIFICATIONS. SEE ARCHITECTURAL PLANS AND ELEVATIONS FOR MILLWORK LOCATION CO REVIEWED AN E APPROVED C OCT 0 5 2009 City of Tukwila BUILDING DIVISION RECEIVED SEP 22 2009 PERMIT CENTEF D09 I 111 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT i • a► r /I/ .e l. fir► TE L. ALLWINE OF WASHINGTON 3380 ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 W F- w L.L. W � � S O z 0 < 0 wm u) W z J w < �� Q m w co o PROJECT -FILE 0921.02 -L201- Elevations DRAWN BY TITLE LOBBY INTERIOR ELEVATIONS SHEET L201 Door # Size Type Material Glazing Threshold Hardware Fire rating Note 001 (2) 36" x V.I.F. (2) SIDELIGHTS A ALUM D 5/L601 SEE BELOW NR door to match surrounding store front windows and doors Door Pull to be Rockwood No RM5240 -18; Finish 313 002 36" x 80" B SC WD _ Match or reuse exist, 20 MIN WORK AREA / OFFICES 003 36" x 80" B SC WD - Match or reuse exist, 20 MIN PUBLIC RESTROOMS 004 36" x 80" D SC WD A Match or reuse exist *, 20 MIN EXERCISE ROOMS *INSTALL NEW OWNER- FURNISHED ELECTRONIC LOCK . 005 40" x 80" V.I.F. F SC WD. VINYL CLAD A SEE BELOW KITCHEN - APPROVED MANUFACTURER: 'ACROVYN DOOR SYSTEMS "; VINYL ACRYLIC CLAD CONSTRUCTION SPECIALTIES. INC. (800- 416 -6586) 006 36" x 80" V.I.F. E SC WD SEE BELOW 20 MIN MEETING ROOM ENTRANCE 007A 007B (2) 28 "x 80.. 36 "x 80" V.I.F. E B SC WD SEE BELOW NR MEETING ROOM CLOSETS, SINGLES & PAIRS NOTES: FOR PLASTIC LAMINATE FACES AT DOOR FRAMES. ADJUST HINGES AS REQUIRED. PAINT COLOR TO MATCH ADJACENT EXTERIOR MATERIALS LOCKSET VARIES DEPENDING ON DOOR LOCATION; REF: HARDWARE SPEC /SECTION 08700 FOR SPECIFIC LOCKSET TYPE MAGNET TO BE TIED TO FIRE ALARM SYSTEM 1. ALLOW 2. EXTERIOR 3. HARDWARE 4. WALL Top of frame to align with top of existing store front system • I Ntk 10" �VIF 3' -0" 3' -0 I}VIFt 6' -0" O FRAME TYPE: 2" HOLLOW METAL FRAME STOREFRONT SYSTEM TO MATCH EXIST. Door Pull Clear Glass STORE FRONT 2" ALUMINUM FRAME W/ DARK BRONZE PATIO DOOR ANODIZED FINISH (U.N.O.) DOOR 001 HARDWARE: (BY ALUMINUM DOOR MANUFACTURER) A. ENTRANCE DOOR HARDWARE SHALL BE SUPPLIED WITH DOORS AS FOLLOWS, UNLESS INDICATED OTHERWISE: 1.CONTINUOUS HINGES, 780 -112 HD, HAGER, KYNAR FINISH, COLOR TO MATCH DOOR. 2. CONCEALED ELECTRICAL POWER TRANSFER, EPT 10, VON DUPRIN 3. PULL: ROCKWOOD #: RM5240 -18, 313 4. WEATHER STRIPPING (3 SIDES) 5. BOTTOM SWEEP 6. HANDICAPPED THRESHOLD, CLEAR ALUMINUM MILL FINISH. B. CONTINUOUS HINGES, ELECTRIC POWER TRANSFERS, PULLS, THRESHOLD & DOOR SEALS FURNISHED BY DOOR SUPPLIER. MAGNETIC LOCKING SYSTEM COMPONENTS AND CONTROLS SHALL BE BY ONE MANUFACTURER, AND SHALL BE LISTED AND LABELED AS A COMPLETE SYSTEM. REFER TO DESIGN GUIDE PROJECT MANUAL FOR ADDITIONAL INFORMATION AND SPECIFICATIONS 1.02 HW SET (BY HARDWARE SUPPLIER) PAIR DOORS EACH PAIR TO HAVE: 2 EA OH CONCEALED CLOSERS 1 EA MAG LOCK 2 EA TOUCHBARS 2 EA FLOOR STOPS 2 EA DOOR LOOPS 1 EA REX BUTTON RELEASE DELAYED ACTION PUSH BUTTON 1 EA KEYSWITCH 1 EA CYLINDER 41 (® KEYSWITCH) 1 EA POWER SUPPLY 1 EA REMOTE CONTROL UNIT 1 EA AIPHONE INTERCOM SYSTEM 1 EA ELECTRONIC CARD READER SCALE: 3" = 1' -0" EXISTING WALL OVERSIZE PLYWOOD BY 1/8" L401 SCALE: 3" = 1' - 0" EXISTING WALL 3/4" MDF BASE DETAIL BASE AS SCHEDULED TRIM DETAIL FLOOR AS SCHEDULED EXISTING FLOOR GWB BUILD -OUT ON CORRIDOR SIDE VINYL WALL FINISH 322 PLAM FINISH 3/4" PLYWOOD BOXOUT SEALANT OVER VWC, TYP. ALL AROUND B.O. TV SOLID CORE WOOD L401 SOLID CORE WOOD W/ LOUVER SCALE: 1/4" = 1' -0" 1 ., 1 SCALE: 1" = 1' -0" SOLID CORE WOOD DOOR 006 HW SET - T20 MEETING ROOM ENTRANCE EACH PAIR TO HAVE: 6 EA HINGES TA2714 4.5 X 4.5 2 EA EXIT DEVICES 9927L 2 EA CYLINDERS 34 2 EA CLOSERS P8501BF —H 2 EA FLOOR STOPS 1231 2 SETDOOR SEALS S7731) DOOR SCHEDULE US26D MCK US26D VDI US26D SAR US26D NOR US26D TRM S88D PEM DOOR 005 HW SET — T31A KITCHEN PROVIDE DOUBLE ACTING FRAME SIZE DOOR TO ACCOMMODATE DOUBLE ACTING SWING EACH DOOR TO HAVE: 3 EA SPRING HINGES 1001 4" 1 EA DEADBOLT 485 2 EA PUSH 1001 -3 2 EA WALL STOP 1270WVCP 2 EA KICKPLATE K0050 18" x 2" LDW US26D MCK US26D SAR US26D TRM US26D TRM US26D TRM EXISTING WALL 7 LCD TV, AND MOUNTING BRACKET, PROVIDED BY OWNER. WD BLOCKING, GC TO COORDINATE WITH MONITOR MOUNTING BRACKET °p in POWER/DATA RECEPTACLE, AV JUNCTION BOX BEYOND, GC TO COORDINATE INSTALLATION VWC ON 5/8" GYP. BD. ON (2) LAYER 3/4" PLYWOOD FRAMING @ 16" OC, SECURED TO PARTITION - SECURE FURRING TO PARTITION BEYOND, PROVIDE BLOCKING, AS REQUIRED HOME THEATER WALL ENTRANCE TO ALLOW VIEW OF INSIDE OF ROOM FROM CORRIDOR SOLID CORE WOOD 1. 2. 3. 4. 5. 6. 7. MCK NOR PEM RIX SAR TRM VD! 1 L401 VISION PANEL SOLID CORE WOOD DOOR 007B - T32 MTG ROOM CLOSETS — SINGLE DOORS EACH DOOR TO HAVE: 3 EA HINGES T2714 4.5 X 4.5 1 EA LOCKSET 28 -10G05 LL 1 EA OVERHEAD STOP 55 -333 3 EA SILENCERS 1229A 1x4 WOOD TRIM (398) METAL TILE TRIM GLASS TYPE: O 1/4" TEMPERED O 1/2" INSULATED © 1" INSULATED OD 1" INSULATED / TEMPERED DOOR 007A HW SET - T32A MTG ROOM CLOSET PAIR DOORS EACH PAIR DOOR TO HAVE: 6 EA HINGES T2714 4.5 X 4.5 US26D MCK 2 EA FLUSH BOLTS 3917 US26D TRM 1 EA DUST PROOF STRIKE 3910 US26D TRM 1 EA LOCKSET 28 -10G05 LL (ACTIVE LEAF)US26D SAR 2 EA OVERHEAD STOP 55 -333 US26D RIX 6 EA SILENCERS 1229A US26D MCK US26D SAR US26D RIX Approved Manufacturers and Abbreviations: McKinney Products Company, An ASSA ABLOY Group Company (800- 346 -7707) Norton Door Controls, An ASSA ABLOY Group Company (800 -438 -1951) Pemko Manufacturing Company (800 283 - 9988) Rixson Specialty Door Controls An ASSA ABLOY Group Company (800 -457 -5670) Sargent Manufacturing Co., An ASSA ABLOY Group Company (800- 727 -5477) Trimco /BBW (Quality) (323- 262 -4191) Von Duprin, an IR Ingersoll -Rand Business (317- 613 -8944) SEE MI DESIGN GUIDELINE SPECIFICATIONS 081400, 087100 FOR ADDITIONAL INFORMATION. 410 PAINT WALL BEHIND TRIM 1x2 WOOD TRIM EXISTING FIREPLACE PORCELAIN TILE ( PAINT GWB PORCELAIN TILE SCALE: 1" = 1' -0" VIF u- N FIREPLACE SECTION ALIGN j t , 4/ ". VIEW PLAN FINISH FLOOR AS SCHEDULED PARTITION TYPE: NON RATED, NON BEARING, LOW WALL SCALE: I -1/2" = I' -0" *AT COLUMNS MATCH COLUMN WIDTH SCALE: I -1/2" = I' -0" ti 5/8" GWB - BASE AS SCHEDULED PARTITION TYPE: NON RATED, NON BEARING, LOW WALL PAINTED WOOD CAP 328 112 "x112" REVEAL WRAP VWC UP & OVER EDGE 3" x 3" x 5/16" x 8" TOP ANGLE WELDED TO EA ANGLE POST 3" x 3" x 5/16" STL L POSTS AT 4' -0" OC WELDED TO TOP ANGLE AND BOT PLATE 3 5/8" MET STUDS AT 16" OC W/ 5/8" GYP BD EACH SIDE 1" 0 HOLE FOR CONDUITS BASE AS SCHEDULED 8" x 3 1/2" x 3/8" STL PLATE. BOLT TO CONC SLAB W /(3) 3/8" 0 ANCHOR BOLTS mi SCALE: 1 1/2" = 1' -0" PAINTED WOOD CAP i /Ir p )__ . LOBBY *REF: 4 / L403 FOR ISOMETRIC VIEW OF FRAMING UL DESIGN NO.: U438 • NOTE: FOR BUILDING BUILT IN NON- COMBUSTIBLE CONSTRUCTION TYPE USE METAL STUDS 112 "x112" REVEAL WRAP VWC UP & OVER EDGE — BRACING AT END OF FREESTANDING WALL PER DET. A I L401 2x4 WOOD STUDS AT 16" OC W/5/8" GYP BD EACH SIDE 1" 0 HOLE FOR CONDUITS 318 "0 ANCHORS THROUGH PLATE , SPACING AS REQUIRED BASE AS SCHEDULED FINISH FLOOR AS SCHEDULED UL DESIGN NO.: U438 DOUBLE STUD AT END OF LOW WALL 3/8" LAG SCREWS TO STUDS L2x2x /8x30" 3/8 V L2x2x 3 4x12 "MIN. 518 "0 ANCHORS THROUGH PLATE WITH 3" EMBEDMENT MIN. WOOD PLATE 2x4 WOOD STUDS AT 16" O.C. NOT SHOWN IN VIEW FOR CLARI END OF LOW WALL BRACING uuuuuuuuuuui 7)i" 4 PARTITION TYPE: NON RATED, NON BEARING, INTERIOR PARTITION SCALE: I - 1/2" I' -0" • uuuuuuuuum PARTITION TYPE: SCALE: I - I /2" = I ' -0" UNDERSIDE OF STRUCTURAL DECK OR FIREPROOFED CEILING EXTENDED TRACK RUNNER SECURED TO DECK TO ALLOW FOR FLOOR DEFLECTION CEILING AS SCHEDULED 35/8" MET STUDS AT 1'-4" OC W/5/8" GYP BD EA SIDE 3" SOUND ATTENUATION BLANKETS- FULL HEIGHT, WHERE INDICATED BASE AS SCHEDULED NON- RATED, NON - BEARING, INTERIOR PARTITION UNDERSIDE OF STRUCTURAL DECK OR FIREPROOFED CEILING EXTENDED TRACK RUNNER SECURED TO DECK TO ALLOW FOR FLOOR DEFLECTION CEILING AS SCHEDULED 6" MET STUDS AT 1'-4" OC W/5/8" GYP BD EA SIDE 3" SOUND ATTENUATION BLANKETS- FULL HEIGHT, WHERE INDICATED BASE AS SCHEDULED FIN. FLOOR AS SCHEDULED FIN FLOOR AS SCHEDULED SHEET NOTES ti REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION RECEIVED SEP 22 2009 PERMIT CENTER X09 - iq 7 3380 SHEET 111 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT` �r L. ALLWINE E OF WASHINGTON ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 w z w U 2 H 0 (/) w J F- F- uJ PROJECT -FILE 0921.02 -L401 -Wall Types & Details DRAWN BY TITLE LOBBY PARTITION TYPES DETAILS & DOOR SCHEDULE L401 (206) 575-2500 PROJECT # 0921.02 PER ELEVATION NOTE: ALL SLAT CEILING CONNECTIONS TO BE SEALED. CONNECT NEW 2 2" MTL FRAMING TO STRUCTURE ABOVE. 1 3Y / 2 / SCALE: 1 1/2".--V-0" NEW 2 I" METAL FRAMING L402) SCALE: 3 " =1' -0" I I I I • EQ. NEW MILLWORK AT S -BAR REFER TO 509b WOOD LATTICE SCALE: 1 1 /2 " =l' -0" EQ. EXISTING ROOF TRUSS ATTACH TO EXISTING STRUCTURE ABOVE. PRESERVE INTERGTITY OF F.R. CEILING / ROOF ASSEMBLY. 'UNISTRUT" SYSTEM ATTACHEMENT IN MIN. (6) LOCATIONS TO BE VERIFIED AND DETERMINED IN FIELD EXISTING GWB CEILING SUPPORT GRID PATCH EXIST. GWB CEILING AS NEEDED LATTICE MOUNTING DETAIL N 1. LINE OF 2X4 CLEAR COATED FINISHED HARDWOOD MAPLE BEYOND NEW $" TYPE "X" GWB 409 NEW 6 " METAL STUD DROPPED GWB AT ACT 1X6 CLEAR COATED FINISHED HARDWOOD MAPLE SLATS ... ..:a14'3^:. •a. •.. earl a :i 4aTw".`.. —F0.. Y.. .�l:••.r.. . w . .we a •.. 1.h �.: :.r. . � v .�. • �i �...i'e.. e.Y.�. i. 6' -0 EQ. PAINT EXIST ACT & GRID +10' -8" AFF V.I.F. 6 L402 " ' +10-8 AFF V.I.F _ • EQ. . CENFTER-EATf1EE ON S -BAR ! -t CENTER PENDANTS OVER COUNTER AT STOOLS, TYP. ' —L! EQ. ' EXISTING ACT EXTEND FRAMING OF EXISTING GWB CEILING. ATTACH TO CUT OUT BULKHEAD FRAMING LINE OF REMOVED BULKHEAD COLUMN BEYOND L402 +9' -0" AFF V.I. REV EQ. ( APROX 5') I EXISTING STRUCTURE ABOVE EXISTING: 1" HAT CHANNEL 16" O.C., 1- 1/2 "'C' CHANNEL SECURED TO STRUCTURE ABOVE W/ #12 WIRE EXISTING NON -RATED GWB CEILING 411 +9' -0" AFF V.I.F. NEW 3 5/8" METAL STUDS 's NEW 5/8" TYPE GWB 409 • L402 16' -0" ; TABLE, CUT -OUT:• SCALE: 1 /4 " =1' -0" CT TOR MAIN, P INT 8' -0" AFF 3 NEW GWB FRAMING AT RECEPTION SCALE: 1 1 /2 " =1' -0" I — — -T •• • • ..... • • • CONNECT NEW 24" MTL FRAMING TO S RUCTURE ABOVE. NEW: ARMSTRONG GWB GRID SYSTEM - 1 -1/4" x 1 -1/4" ANGLE MOLDING, CROSS TEES @4' O.C, MAIN BEAMS @4' O.C. SECURED TO STRUCTURE ABOVE W/ #12 WIRE SECTION AT SUSPENDED CEILING L40 SCALE: 1— 1 /2 " =1' -0" EQ. (APROX 5') PLACE EDGE OF DROPPED CEILING CLC SEST TO FLOOR TRANSITION BELOW I LINE OF COMMUNAL TAE LE BELOW - -COMMUNAL TABLE & CUT -OUT IN GWB DROPPED CLNG 0 4" X 6' CUT OUT FOR PENDANT LIG T FIXTURES 0 DECORATIVE PENDANTS MOUNTED TO CLN G ABOVE. MOUNTING RODS TO BE CENTERED IN 4 "x6' CUT -OUT BOTTOM OF JGHT FIXTURE SHADE TO BE AT 6' -0" A.F.F. - CENTERED OVER TABLE. ■ ENLARGED REFLECTED CEILING PLAN • . • NEW ACT • I 407) 2'x2' • _41C9 SHEET NOTES 1. REFER TO INTERIOR FINISH INDEX FOR FINISH INFORMATION. 2. REFER TO REFLECTED CEILING PLAN ON L104 FOR COMPLETE CEILING INFORMATION. C REVIEWED FOR ODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIIISIrm RECEIVED SEP 22 2009 PERMIT CENTER. b oc [ cr7 Greg L. Allwine ARCHITECT ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 w I— Li- o o- w z o: 0< z >--' w o0 w < co cc) PROJECT -FILE 0921.02 -L402- Enlarged RCP DRAWN BY TITLE LOBBY HARD LID & S -BAR CEILING DETAILS SHEET 3380 111 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT L. ALLWINE E OF WASHINGTON L4O2 " 1" NOSING L403 / SCALE: 3" = 1' -0" SCALE: 3" = 1' -0" 11" MIN V.I.F. NEW TILE AS SCHEDULED 115 SLIP RESISTANT CONTRASTING COLOR STRIP AT LEADING EDGE OF EACH RISER SOLID GROUT THE UNDERSIDES OF NOSINGS SHALL NOT BE ABRUPT. THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE NO GREATER THAN 1/2 IN. NOTE: GC TO PROVIDE ADA COMPLIANT CONTRASTING TILE NOSING STRIP WITH DIMENSIONS SHOWN. COORD COLOR WITH MARRIOTT REPRESENTATIVE. ; LOBBY TREAD DETAIL 1 1y" / 1 1/2" DIA BRUSHED NICKEL HANDRAIL JULIUS BLUM HANDRAIL BRACKET, MODEL # 389, BRUSHED NICKEL FINISH "CLOVER" PHOTO MURAL BEYOND FINISHED WALL B. RAMP HANDRAIL ADJACENT TO "CLOVER" PHOTO MURAL WALL A. TYPICAL HANDRAIL 1 1/2" DIA BRUSHED NICKEL HANDRAIL JULIUS BLUM HANDRAIL BRACKET, MODEL # 376, BRUSHED NICKEL FINISH FINISHED WALL U- U- CV LOBBY HANDRAIL DETAILS WALL CAP WITH 1/2" REVEAL 5/8" GWB ON BOTH SIDES 3 5/8" METAL STUD 16" ON CENTER STEEL PLATE, POST, AND TOP ANGLE ASSEMBLY EVERY 4' ON CENTER L403 SUNKEN LOUNGE PARTITION - ISOMETRIC SCALE: NTS EXTEND HANDRAIL HORIZONTALLY PAST BOTTOM NOSING: WRAP CORNER FOR MIN 1' -11" TOTAL EXTENSION. L403) SCALE: 1/4" = l' -0" EXTEND HANDRAIL HORIZONTALLY PAST TOP NOSING: WRAP CORNER FOR MIN 1 FT TOTAL EXTENSION. N EXTEND HANDRA L PAST BOTTOM NOSING: SLOPING AT A DISTANCE EQUAL TO ONE TREAD PLUS 1FT HORIZONTALLY LOBBY HANDRAIL DETAILS NEW WALL LOWERED LOUNGE CD >< 4" SLAB NEW WALL BEYOND - 2' -6" TOTAL HANDRAIL EXTENSION - BOTTOM 1 le \ I 1' TOTAL HANDRAIL EXTENSION -TOP LOCAL LIBRARY REF: SHEET 12/504 LOWERED LOUNGE PROVIDE WATERPROOFING MEMBRANE TO PROTECT NEW WALL EXPANDED POLYSTYRENE 12" #4 DOWELS @ 1' O.C. MIN. 4" EMBED WITH EPDXY GROUT. 3 L403 4" LIGHTWEIGHT CONCRETE SLAB WITH FIBERGLASS FIBERS NEW WALL- MATCH HEIGHT OF EXISTING WALL RAISED PLATFORM SECTION SCALE: 3/4" = 1' -0" PATCH AND REPAIR EXISTING WALL AND FURNISH NEW CAP 12'_4 1/2" AREA OF NEW PLATFORM NEW CONCRETE SLAB LINE OF EXISTING PLATFORM EXISTING WALL NEW WALL- FLUSH W/ EXISTING L403 PROVIDE WATERPROOFING MEMBRANE TO PROTECT EXISTING WALL RAISED PLATFORM SECTION SCALE: 3/4" = 1' -0" SCALE: 1/4" = 1' -0 EXISTING PLATFORM CUT BACK 1 FT FOR NEW CONC. EDGE. 12" #4 DOWELS @ 1' O.C. MIN 4" EMBED. SUNKEN LOBBY EN 6 bO icrl LOBBY RAMP REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila EXISTING SLAB. r .c- • 1 re �►P �a fir ' '% ► %i r� o 63 L403 RECEIVED SEP 2 2 2009 PERMIT CENTEF, . Greg L. A swine ARCHITECT ISSUE /REVISIONS ISSUE TO HPC 08 - 06 - 09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 W _ i Li.o o E t z o < H z >- W co > z n/ W Q IC D J v CO PROJECT -FILE 0921.02 -L403- Sunken Lounge Details DRAWN BY TITLE LOBBY SUNKEN LOUNGE DETAILS SHEET 111 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 Ct w F- z w U I H 0 w F- F- w AMIIIPPIPAPPIN T a) co �ao L co R3 CL a a) Q Y L403 LINE OF STONE TRANSACTION TOP ABOVE 2" DIA GROMMET ALL VISIBLE INTERIOR SURFACES OF BACK OF PEDESTAL TO BE 12 "x12" REMOVABLE ACCESS PANEL IN BASE, (EA) SIDE 2" DIA. CUTOUTS FOR CABLE MANAGEMENT POWER /DATA RECEPTACLES, GC TO COORDINATE INSTALLATION N t N- N PROVIDE FRAMING AND WOOD BLOCKING AS REQ'D 1 3/8" CASH INSERT, IN DRAWER, 16 "W x 11.5D x 2.5 "H LOCATION OF IBM INFOPRINT 1532 EXPRESS LASER PRINTER 17 "W X 20 "D X 14 "H, PROVIDED BY OWNER, ON SLIDING PRINTER TRAY 1 3/4" 3/4" THICK PLYWOOD, PROVIDE WOOD BLOCKING AND FRAMING AS REQ'D WELCOME PEDESTAL MILLWORK PLAN SECTION SCALE: I 1/2" = I ' -0" 1 3/8" WELCOME PEDESTAL MILLWORK PLAN SECTION SCALE: I 1/2" = I ' -0" WELCOME PEDESTAL MILLWORK PLAN SECTION SCALE: I I /2" = I ' -0" L 3" SCALE: I 1/2" = I ' -0" 1' - 1/4" 8 1/2" 4' -10 1/8" WELCOME PEDESTAL MILLWORK PLAN SECTION. LINE OF WO'KSURFACE TOP- ABOVE LINE OF ORKSURFACE TOP N G.C. TO COORDINATE LOCA OF FLOOR BOX IN Fl PROVIDE CONDUIT B/N PEDES UNI 7 5 5/8" PENCIL CUP GROMMET, ITEM #M01 8865, CONTACT WW.MODERNOFFICEINTERIORS.COM LINE OF STONE TRANSACTION LEDGE LINE OF STONE TRANSACTION LEDGE LOCATION OF WYSE THIN CLIENT EQUIPMENT, 3 "x12 "x11.5 ", PROVIDED BY OWNER LINE OF STONE TRANSACTION LEDGE ABOVE LINE OF BASE BELOW PROVIDE FRAMING AND WOOD BLOCKING AS REQ'D LINE OF PANELS ABOVE, SEE 1/500a FOR MORE INFO t AYERS 3/8" PLYWOOD W/ PLAIN SLICED WALNUT VENEER, CLR NATURAL FINISH, LINE OF BASE CABINET ABOVE; SEE 2a /500a LINE OF CABINET WORK ABOVE; SEE PLAN SECTION 1/500a BA E ON PLYWOOD SUBSTRATE CO N- N rn 2 1/8" e I- 1/4 WELCOME PEDESTAL SOLID SURFACE COUNTER PLAN SCALE: I I/2 ".= 1' -0" / / / / /5 SCALE: I I /2" = I' -0" SCALE: I I /2" = I' -0" SCALE: 1 1/2" = 1 ' -0" 2' -1 3/4" 1' -5 7/8" LINE OF CABINET EDGE BELOW cPs 2' -2 1/8" LINE OF PEDESTAL EDGE ABOVE LINE OF PEDESTAL EDGE WELCOME PEDESTAL PLAN 5' -0 5/8" 4' -7 3/8" 0 3' -1 1/2" 2' -6 1/8" 2' -1 7/8" 0 WELCOME PEDESTAL SOLID SURFACE COUNTER PLAN WELCOME PEDESTAL SOLID SURFACE COUNTER PLAN 8 m CNI R2" CO r. 6 1/2" NOTE: GC TO COORD FINAL COUNTERTOP SIZES W/ OVERHANG DIMENSIONS INDICATED ON PLAN SECTIONS NOTE: GC TO COORD FINAL COUNTERTOP SIZES W/ OVERHANG DIMENSIONS INDICATED ON PLAN SECTIONS NOTE: GC TO COORD FINAL COUNTERTOP SIZES W/ OVERHANG DIMENSIONS INDICATED ON PLAN SECTIONS REFERENCE NOTES 1. ALL LOCKS REGISTRATION AREA MILLWORK —. FOCAL WALL AND WELCOME PEDESTALS TO BE ON SAME KEY. 2. FINISH COVER PLATES & RECEPTACLES IN ALL MILLWORK PIECES TO MATCH ADJACENT FINISH COLORS. 3. MILLWORK PART OF PEDESTAL IS FF &E ITEM # LM -250R (LM -250L) FURNISHED BY OWNER. DETAILS SHOWN FOR INFORMATION AND COUNTER SOLID SURFACE FABRICATION ONLY. 4. GC TO FURNISH AND INSTALL SOLID SURFACE TOP AS SHOWN IN SECTION DETAIL. 5. SOLID SURFACE EDGE TO BE 11" THICK AND OVERHANG THE MILLWORK BY 1 ". 1. ALL LOCKS IN FOCAL WALL AND WELCOME PEDESTALS TO BE ON SAME KEY. 2. GC TO COORDINATE FINAL EQUIPMENT SIZES WITH PROJECT MANAGER PRIOR TO MILLWORK FABRICATION AND ADJUST ACCORDINGLY. 3. FINISH COVER PLATES Sc RECEPTACLES IN ALL MILLWORK PIECES TO MATCH ADJACENT FINISH COLORS. 4. GC TO FURNISH AND INSTALL SOLID SURFACE TOP AS SHOWN IN PLAN AND SECTION DETAILS. 5. SOLID SURFACE EDGE TO BE 1i" THICK AND OVERHANG THE MILLWORK BY 1 ". 6. INTERIOR SURFACES OF PEDESTAL MILLWORK TO BE BLACK MELAMINE. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION RECEIVED SEP 22 2009 PERMIT CENTEE bo3. I co Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT' 'r . 4j ,, � l f $ LLWINE ra TE OF WASHINGTON • SHEET 3380 ISSUE /REVISIONS w H F- 1— O O Z 0< Z >- wm Z w Q CO 0 _ v (I) ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 Ct w z w U 2 H 0 Cf) w J F- F- w P 0921.02- 500a -CL- Welcome Pedestals DRAWN BY TITLE WELCOME PEDESTALS 500a PULLS: EPCO, DP41 -A-3" EPCO PULLS, EPC- DP41 -A -3, TYP TIMBERLINE LOCKS WELCOME PEDESTAL SECTION SCALE: 1 I /2" = I ' -0" SCALE: 1 1/2" = 1 ' -0" PLAIN SLICED WALNUT VENEER, CLEAR NATURAL FINISH, 383 VARIES BASE 1' -2 3/8" WELCOME PEDESTAL SECTION VARIES 3 1/2" PLAIN SLICED WALNUT VENEER, CLEAR NATURAL FINISH, MIRROR TO COVER BACK PANEL OF SETBACK PLAIN SLICED WALNUT VENEER, CLEAR NATURAL FINISH, BLOCKING AS REQ'D i" REVEAL - PAINTED BLACK REMOVABLE ACCESS PANEL BLOCKING AS REQ'D REMOVABLE ACCESS PANEL PLAIN SLICED WALNUT VENEER, CLEAR NATURAL FINISH, LOCATION OF WYSE THIN CLIENT EQUIPMENT, PROVIDED BY OWNER PLAIN SLICED WALNUT VENEER, CLEAR NATURAL FINISH, PLAIN SLICED WALNUT VENEER, CLEAR NATURAL FINISH, N WELCOME PEDESTAL ELEVATION SCALE: I I /2" = I ' -0" WELCOME PEDESTAL ELEVATION SCALE: I I /2" = I ' -0" ■mmmwrEfdpi=" TIMBERLINE LOCK LOCATION OF WYSE THIN CLIENT EQUIPMENT, PROVIDED BY OWNER GRAIN Ad i iiiwiii- EPCO PULLS, TIMBERLINE LOCKS EPC- DP41 -A -3, TYP �� S� � � 3a loom 1111711111Mentgoi /tall i" REVEAL PNT. BLACK SLIDING SHELF N ss :ii i�isi rsiilIi PLAIN SLICED WALNUT VENEER, CLEAR NATURAL FINISH, 383 , PULL OUT TRAY , DRAWER ON GLIDES WITH CONTINUOS FRONT LOCATION OF IBM LASER PRINTER 14" X 17" X 20 "; PROVIDED BY OWNER PLAIN SLICED WALNUT VENEER, CLEAR NATURAL FINISH, (383) POWER /DATA RECEPTACLE, GC TO COORDINATE INSTALLATION , PULL OUT PRINTER TRAY i" REVEAL PAINTED BLACK LOCATION OF IBM LASER PRINTER 14" X 17" X 20 "; PROVIDED BY OWNER POWER /DATA RECEPTACLE, GC TO COORDINATE INSTALLATION REFERENCE NOTES 1. ALL LOCKS . REGISTRATION AREA MILLWORK - FOCAL WALL AND WELCOME PEDESTALS TO BE ON SAME KEY. 2. FINISH COVER PLATES & RECEPTACLES IN ALL MILLWORK PIECES TO MATCH ADJACENT FINISH COLORS. 3. MILLWORK PART OF PEDESTAL IS FF &E ITEM # LM -250R (LM -250L) FURNISHED BY OWNER. DETAILS SHOWN FOR INFORMATION AND COUNTER SOLID SURFACE FABRICATION ONLY. 4. GC TO FURNISH AND INSTALL SOLID SURFACE TOP AS SHOWN IN SECTION DETAIL. 5. SOLID SURFACE EDGE TO BE 1i" THICK AND OVERHANG THE MILLWORK BY 1". 1. ALL LOCKS IN FOCAL WALL AND WELCOME PEDESTALS TO BE ON SAME KEY. 2. GC TO COORDINATE FINAL EQUIPMENT SIZES WITH PROJECT MANAGER PRIOR TO MILLWORK FABRICATION AND ADJUST ACCORDINGLY. 3. FINISH COVER PLATES & RECEPTACLES IN ALL MILLWORK PIECES TO MATCH ADJACENT FINISH COLORS. 4. GC TO FURNISH AND INSTALL SOLID SURFACE TOP AS SHOWN IN PLAN AND SECTION DETAILS. 5. SOLID SURFACE EDGE TO BE 1i" THICK AND OVERHANG THE MILLWORK BY 1 ". 6. INTERIOR SURFACES OF PEDESTAL MILLWORK TO BE BLACK MELAMINE. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION RECEIVED SEP 22 2039 PERMIT CENTER t�9197 3380 :t�i+F tie .a , Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED - ARCHITECT J 'AO . ALLWINE • . E OF WASHINGTON ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 w H Z W W 11 H LL 0 Ct Z < Q w m z J w < Ct >- m= W M 0U CIS SHEET L 0 0 C H AWE PROJECT -FILE 0921.02- 500b -CL- Welcome Pedestals DRAWN BY TITLE WELCOME PEDESTALS 500b 0 0 0 0 0 0 0 0 0 1' -1 1/16" 0 0 0 0 0 0 1' -2" SECTION 1' -5" 0 0 0 0 0 0 0 0 SCALE: 1 1/2" = 1' -0" 0 0 ACCESS PANEL 2" N a LL. 1" PENETRATE ACT AS NEEDED AND INSTALL METAL STUDS SUPPORT TO SECURE MILLWORK TO STRUCTURE ABOVE FOR STABILITY EXISTING ACT CEILING ABOVE LIGHTOLIER —A GENLYTE GROUP, USC -1- 2617 —EBKB, UNDER CABINET LIGHT POWER / DATA RECEPTACLE BLACK MELAMINE INTERIOR 3/4" BLACK MELAMINE ADJUST. SHELVING EDGE BANDED PAINT WHITE LIGHTOLIER— A GENLYTE GROUP, SN 3S 125 HPF- 120 —SO, FLUORESCENT STRIP LIGHT, (2) STAGGERED. REMOVABLE PLEXIGLASS PANEL, COLOR :WHITE MILK PROVIDE SS CLIPS AT THREE SIDES OF PLEXIGLASS OPENING 0 1' -4" H \—SAFET) DEPOSIT BOX, VIF DIMEN1IONS W/ MILLWORK 2' -2 CLR r i MINIMUM 2' -5" SECTION SCALE: 1 1/2" = - ... eN (7,Z re m � b y h - Gd'y► A '� acc vt•hT 1 k 6" xl (2) LAYERS 3/4" PLYWOOD FRAMING ALIGN SECTION @ FRONT SIDE CABINET SCALE: 1 1 /2" = 1 '- QUARTER SAWN ASH, (386) QUARTER SAWN ASH, QUARTER SAWN ASH CABINET FRONT, 686) EXISTING ACT CEILING ABOVE PENETRATE ACT AS NEEDED AND INSTALL METAL STUDS SUPPORT TO SECURE MILLWORK TO STRUCTURE ABOVE FOR STABILITY FINGER PULL BLACK MELAMINE INTERIOR LINE OF CABINET BEYOND 6. _ / issuer =i =s =: II 11 I, 1' -6 3/4" 0 I N (__ SECTION SCALE: 1 1/2" = 1' -0" FINGER PULL BLACK MELAMINE INTERIOR. 3/4" BLACK MELAMINE ADJUST. SHELVING EDGE BANDED QUARTER SAWN ASH CABINET FRONT, EXISTING ACT CEILING AE QUARTER SAWN ASH, 386 ON 3/4" PLYWOOD ON (2) LAYERS 3/4" FRAMING 116" OC 386 501 ' '1111' ' 2' -8" MIN r 111/2" 501 EQ. a FRONT LOCKS .215 SIDE CABINET 2 ,1 EQ. b 10 -3" EQ. b EQ. 11 1 2 "' PUN Ileti e 1 ' I 386 2' CO in 3' -0" MIN CLR. SEAMS, TYP QUARTER SAWN ASH, STAINED ELEVATION SCALE: 1 /2" = 1' -0 ". ELEVATION SCALE: 1/2" = 1' -0" SCALE: 1/2" = 1'0" SCALE: 1 /2" = 1' -0" POWER /DATA AND TELEPHONE RECEPTACLES LINE OF CARCASS BELOW PLAN - UPPER WALL W /ALCOV I \:XISTING 1 AFETY DEPOSIT BOX ERIFY SIZE IN FIELD ADJUST ENCLOSURE S NEEDED ^ I\ / U / 501 L. 3' -0" MIN . CLR 1/2" 1' -5" 6' -11" PLAN SECTION @ SAFETY DEPO IT BOXES REFERENCE NOTES 1. GC TO VERIFY SAFETY DEPOSIT BOX DIMENSIONS IN FIELD AND TO ADJUST MILLWORK ACCORDINGLY PRIOR TO FABRICATION. 2. GC TO VERIFY EXACT LOCATION OF THE FIRE ENUNCIATOR PANEL IN FIELD AND TO ADJUST ANGLE OF FOCAL WALL AS NEEDED TO COMPLY WITH REQUIRED VISIBILITY OF DEVICE FROM MAIN ENTRANCE. 3. FINISH COVER PLATES & RECEPTACLES IN ALL MILLWORK PIECES TO MATCH ADJACENT FINISH COLORS. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISinN RECEIVED SEP 22 2069 PERMIT CENTEF 111 mss Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 Ct w Z ° Li) W i ti V� N LL. z O Q p I— 2 (i) Z w m W Q Z —1 wQ L >- L cn s ei5 � CO < > - w 0 O o .--I 0 �I — w I F. LO 0 PROJECT -FILE 0921.02- 501 -Focal Wall DRAWN BY TITLE FOCAL WALL SHEET 501 • SECTION SCALE: 1 1/2" = I ' -0" 5 1/2" METAL STUDS & 5/8" TYPE X GWB ATTACHEMENT TO CEILING ABOVE OR STRUCTURE ABOVE AS NEEDED FOR STABILITY SIGNAGE TO BE SUPPORTED BY CONCEALED GROOVES IN SHELVING. POWER /DATA RECEPTACLE EPCO, DP41 3" ALUMINUM PULL, ALSO PROVIDE . LOCKSET GOBOARD SERVER & EQUIPMENT 3/4" ADJUSTABLE SHELF ON PINS & BUSHINGS BLACK MELAMINE INTERIOR 170' SELF CLOSING HINGES 1" VENTILATION REVEAL (4) 1"0 HOLES, EQUALLY SPACED, ABOVE MONITOR RECESS (4) 1 "0 HOLES, PAINTED BLACK, EQUALLY SPACED, ABOVE MONITOR RECESS ALIGN WD VENEER ON 1" PLYWOOD, PROVIDE BLOCKING, AS REQUIRED, FOR MONITOR MOUNT 57" SAMSUNG MONITOR, MODEL #MF57A, W/ PEERLESS SMARTMOUNT, MODEL # SF660 W/ DEEP ADAPTER BRACKET. PROVIDED BY OWNER, GC TO COORDINATE INSTALLATION W/ MILLWORK POWER /DATA RECEPTACLE, AV JUNCTION BOX BEYOND, GC TO COORDINATE INSTALLATION AND FINAL LOCATION WD VENEER ON 3/4" PLYWOOD 1/4" NOTCH © ALL CORNERS, FULL LENGTH, TYPICAL WD VENEER ON 3/4" PLYWOOD ON 3/4" PLYWOOD FRAMING (2) LAYERS ® 16" OC SECURE TO FLOOR W/ PAF'S 24" OC, MIN 1/2 x 1/2" REVEAL, PTD. BLACK SECTION SCALE: 1/2" = I' -0" w I ' 1/2" S.S. RODS OPEN TYPICAL LU SCALE: 1/2" = I' -0" ELEVATION 1' -6" II I I I II ,II I li I A" CONTACT GRAPHIC SYSTEMS FOR SIGNAGE, SEE REFERENCE NOTE #1. SIGNAGE TO BE SUPPORTED BY CONCEALED GROOVES IN SHELVING. (2) LAYERS 1" PLYWOOD SHELVING SUPPORTED BY 1 /16 "X3/4 "X3/4" ALUMINUM TUBE (6061 —T6), ROUTED INTO AND SECURED TO 3/4" PLYWOOD STUDS (2 LAYERS ® 16" OC) W/ #8 SCREWS (2024 -74) 6" 0 FINISHED TRASH CUTOUT, W/ STAINLESS STEEL LINER EPCO, DP41 3" ALUMINUM PULL, ALSO PROVIDE LOCKSET 3" 0 VENTILATION CUTOUT WASTE RECEPTACLE, NIC BLACK MELAMINE INTERIOR SEAMS, TYP QUARTER SAWN ASH, CO CD itak Alit 215 ELEVATION - GoBoard SIDE SCALE: 1 /2" = I ' -0" EQ 11" EQUAL Ills SCALE:.I /2" = I' -0" L - - -J 000 EQ 6' -0" ANH VERIFY W/ EQUIPMENT EQ EQUAL / 2" CLR EQ N LM -813 LM -814 N REMO ACCESS PANEL \ \ FILLER PANEL 1" VENTILATION REVEAL AGAZINE RACK FILLER PANEL ELEVATION - COFFEE SIDE SCALE: 1/2" = 1' -0" 57 SAMSUNG MONITOR, MODEL #MF57A, W/ PEERLESS SMARTMOUNT, MODEL # SF660 W/ DEEP ADAPTER • BRACKET: PROVIDED BY OWNER, GC TO COORDINATE INSTALLATION W/ MILLWORK PLAN 2 " CLR 8' -0" PROTOTYPICAL NO GREATER THAN 9' -0 ", NO LESS THAN 7' -0" REFERENCE NOTES 1. CONTACT GRAPHIC SYSTEMS FOR COFFEE SIGNAGE. CONTACT: JACKIE DIFFENBAUCH @ (316) 267 -4171. 2. FINISH COVER PLATES & RECEPTACLES IN ALL MILLWORK PIECES TO MATCH ADJACENT FINISH COLORS. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION RECEIVED SEP 2 2 2009 PEHMUF CENTER b0c1%.197 SHEET 3380 111 ISSUE /REVISIONS w w w V �� o ° F._ z � o < 0 w m W z° � }� Q CO 0 LLI � U C/) Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT 'r O � � � E ' L. ALLWINE TE OF WASHINGTON ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 PROJECT -FILE 0921.02- 502 - GoBoard Coffee DRAWN BY TITLE GOBOARD & COFFEE 502 EQUAL VARIES 5' -0" EQUAL 322) ��I�1� f ,jl� ��� jil S I��i ----- -- :a - - - - -� -- - -- - „_� ■ .0 -,Z • I �ia1t!n i1lifilLft , ems - ®� • �nm N9 Mral tr )L -,Z IRI1IJL ..i ■ 1' - 3" EQ 1' -6" 1' -6" EQ 1 '-3" N (2) LAYERS 1" PLYWOOD SHELVING SUPPORTED BY 1 /1 6"X3/4"X3/4" ALUMINUM TUBE (6061 -T6), ROUTED INTO AND SECURED TO 3/4" PLYWOOD STUDS (2 LAYERS ® 16" OC) W/ #8 SCREWS (2024 -74) LM -807 LM -811 19' -0" V.I.F. SCALE: 1 /2" = 1' -0" 6' -0" 00000 ELEVATION - LIBRARY SHELVING SECTION - BUSINESS CENTER SCALE: 1 1/2" = 1' -0" Oro N i r) 22 1' -0 " SECTION QUICK PRINT SCALE: 1 1/2" = ' -0" ELEVATION SCALE: 1 /2" = 1' -0" 1 1/2" REVEAL I �t m ffi I n I ' L (2) EQ DOORS 4" (2) EQ DOORS PLAN DETAIL SCALE: 1 /2" = 1 ' -0" VARIES =94 EPCO, DP41 -A -3 PULLS WITH TIMBERLINE LOCKSET 3/4" ADJUSTABLE SHELF ON PINS & BUSHINGS BLACK MELAMINE INTERIOR 1' -0" OPEN SLOT PROVIDE CONVENIENCE OUTLET & DATA LAPTOP STATION. ELEVATION BUSINESS CENTER GRAIN 3/4" PLYWOOD STUDS, PAIRED AT 16" ON CENTER (2) LAYERS 1" PLYWOOD, WITH LAMINATE 308 PRINTER POWER /DATA RECEPTACLE TUBE STEEL 1i "x 1 3 "x ", US 10B FINISH W/ STL TUBE VERTICAL SUPPORTS EACH END. HAFELE CABLE CLIP ITEM # 631.39.301 (6) EA. SIDE 3" X 3" X 12" STEEL BRACKET, US 10B FINISH POWER /DATA RECEPTACLE 1/2" REVEAL PAINTED BLACK SECTION BUSINESS CENTER SCALE: 1 1/2" = 1 ' -0" 3" ELEVATION BUSINESS CENTER SCALE: 1/2" 1 ' -0" NOT USED NOT USED NOT USED 8' -0" PROTOTYPICAL VIF VIF PROVIDE CONVENIENCE OUTLET CO EA SEAT (4). 1'' -9Y" v LAPTOP CONNECTIVITY STATION (0 EQUAL SCALE: 1 /2" = 1' -0" SCALE: 1/2" = 1' -0" PLAN - BUSINESS CENTER REFERENCE NOTES 1. FINISH COVER PLATES & RECEPTACLES IN ALL MILLWORK PIECES TO MATCH ADJACENT FINISH COLORS. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION RECEIVED SEP 22 2039 PERMIT CENTEF 111 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 3380 REGISTERED ARCHITECT' I� : i4/ tr4 L. ALLWINE E OF WASHINGTON ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 w Z l� I-- u-- 0 0 �/ LL Z LL O < 2 Z w > o Z � wQ CO X CO D O 0 J DRAWN BY TITLE SHEET Z ° O UJ � ::::::) ti 0 UJ O UJ Q U) d H PROJECT -FILE 0921.02- 504 - Business -Quick Print BUSINESS CENTER & QUICK PRINT boc?- 147 504 CO o err rn o YW F- a 0 0 0 0 0 0 V.I.F. 1' -7 1/2" SECTION SCALE: 1 1/2" = 1' -0" 0 0 0 BARRISTER DRAWER SLIDE, ROCKLER #1874 BLACK MELAMINE INTERIOR EPCO, DP41 3" ALUMINUM PULL, ALSO PROVIDE LOCKSET ADJ ROUTED SHELVING ON RECESSED PINS 0 AND BUSHINGS 32MM OC OPEN BACK FOR VENTILATION REINSTALL EXISTING FREEZER IN NEW MILLWORK. REINSTALL EXISTING FREEZER IN NEW MILLWORK. EPCO, DP41 3" ALUMINUM PULL, ALSO PROVIDE LOCKSET U, 0 i CV CO // J SECTION SCALE: 1 1/2 " 1' — 3/4" PLYWOOD BOXOUT, FLUSH W/ WALL FINISH " SECTION MEGAWALL POWDER COAT HEARTY ORANG 1" OC, 36"X24" ONE SIDED SLAT SYSTEM, WWW.MEGAWALL.COM 1' -5" PREFERRED ° 1' -0" MIN CLEAR ° BARRISTER DRAWER SLIDE, ROCKLER #1874 TRANSFORMER O 0 TO POWER OUTLET O 0 1' -6 3/4" ° 1' -5" PREFERRED O 1' -0" MIN CLEAR ■s :mss ■rte III EPCO, DP41 3" ALUMINUM PULL, ALSO PROVIDE LOCKSET WASTE RECEPTACLE ACCESS 00 . N 8 "X13 "X15" WASTE RECEPTACLE, BY OTHERS 322 1/4" REVEAL —7 1/2" SECTION SCALE: 1 1/2 " = 1' -0" SCALE: 1 1/2" = 1'— BLACK MELAMINE INTERIOR ADJ ROUTED SHELVING ON RECESSED PINS AND BUSHINGS >: 32MM OC PULL OUT COUNTER, 3os W /ALUM PULL, ROUND 7,0. ALUM FINGER PULL EPCO, DP41 3" ALUMINUM PULL, ALSO PROVIDE LOCKSET J t 2' -0 " +/— TYP. EPCO, DP41 3" ALUMINUM PULL, ALSO PROVIDE LOCKSET 1' -7 1/2" SECTION 2 " SCALE: 1 1 /2" = 1'— If BARRISTER DRAWER SLIDE, ROCKLER #1874 BLACK MELAMINE INTERIOR EPCO, DP41 3" ALUMINUM PULL, ALSO PROVIDE LOCKSET WD. FRAME & 1/4" TEMP GLASS DOOR BARRISTER DOOR SLIDE, ROCKLER #18235 1x2 WD. FASCIA TO SCREEN LIGHT FIXTURE 12" LONG LED LIGHT FIXTURE. LINEAR LED MODULE BY LED LIGHT, MNTD. ACROSS FASCIA CUSTOM WOOD WINE SHELF; BLOCKING AS REQUIRED EPCO, DP41 3" ALUMINUM PULL, ALSO PROVIDE LOCKSET ADJ ROUTED SHELVING ON RECESSED PINS AND BUSHINGS 32MM OC 322 MICROWAVE REF FOOD & BEV EQUIP. SCHEDULE. SSM COUNTER ON 3/4" PLYWOOD FRAMING, C3 - 6 - 6) STAINLESS STEEL SILVERWARE CYLINDERS 215 2 " MIN 2' -8" VIF DEDICATED POWER RECEPTACLE SECTION SCALE: 1 1/2" 1'- REFERENCE NOTES 1. CONTACT GRAPHIC SYSTEMS FOR SIGNAGE. CONTACT: JACKIE DIFFENBAUCH @ (316) 267 -4171. 2. FOR THE MARKET SHELVING SYSTEM INFORMATION CONTACT: TOMMIE HIGHFILL RDC CYTEX 11502 CHARLES ROAD HOUSTON, TX 77041. (832) 590 -6204. TOMMIE HIGHFILL 3. FINISH COVER PLATES & RECEPTACLES IN ALL MILLWORK PIECES TO MATCH ADJACENT FINISH COLORS. 4. FOR MARKET LAYOUT AND ELEVATIONS RE: L110 5. CABINET MAKER SHALL PROCURE THE CABINET LIGHT, INSTALL IN THE WINE CABINET AND DELIVER THE FINISHED CABINET W/ LIGHT READY TO PLUG INTO THE POWER OUTLET IN THE FIELD. THE LIGHT SHALL BE MODE #AO -12 -INCH, WARM WHITE W/ POWER SUPPLY MODEL # AO 30W. THE LIGHT AND POWER SUPPLY SHALL BE BY LEDLIGHT.COM (ON -LINE) OR THE LED LIGHT INC. 1617 FAIRVIEW DR., SUITE 27 -28, CARSON CITY, NV 89702 (775) 84 -4490 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION „ U, co 0 U, t97 111 Greg L. Allwine ARCHITECT I. F i- LL O O L.L. Z Lt 0< LW co Z LLJ < 0 SHEET 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT` fit; • E ►/L. ALLWINE OF WASHINGTON 3380 ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 w z w U S H 0 CO w J F- F- w Ci) PROJECT -FILE 0794.03- 506 -CL -The Market DRAWN BY TITLE THE MARKET RECEIVED SEP 22 2009 PERMIT CENTEF 506 co 5 22" LCD FLAT SCREEN TV W/ RECESSED MOUNT POWER /DATA RECEPTICLE FURNITURE GRADE OUTLET SECTION SCALE: I I /2" = I ' -0" 6 6" it CD 3/8" LAG SCREWS TO STUDS L 2 x 2 x x 30" EXIST. COLUMN " EQ SCALE: I " = I ' -0" FLAT SCREEN TV ABOVE PLAN SECTION BOTTOM SCALE: I " = I ' -0" 13" 12" 13" PLAN SECTION SCALE: I " = I ' -0" 1 1/2" .4 VERIFY W/ EQUIPMENT 3' -2" PLAN SECTION SCALE: I " = I ' -0" 26" OUTLINE OF TRENCH IN CONCRETE FOR INCOMIMG POWER DRILL THRU WOOD PLATES FOR WIRING EXACT LOCATION TO BE VERIFIED IN FIELD " REMOTE RECESS EQ TV RECESS PLAN SECTION TOP (2) 5/8 "0 ANCHORS THROUGH PLATE WITH 3" EMBEDMENT MIN. REMOVABLE BACK PANEL ATTACH WITH FINISH SCREWS AND WASHERS 2 x 2 x/6 x 30" 2 x 2 x x 9 REMOTE CONTROL RECESS FLAT SCREEN TV ABOVE 1/4" BEVEL AT FOUR SIDES TO INCLUDE TV RECESS ABOVE MEDIA POD MONOLITH FLAT SCREEN TV W/ BRACKET FLAT SCREEN TV BELOW N MEDIA POD MONOLITH 22" LG LCD INTEGRATED HDTV, MODEL #: 2OLS7D AND RECESSED MOUNTING BRACKET, PROVIDED BY OWNER. NOTE: MEDIA POD IS FF&E FURNISHED BY OWNER. DETAILS SHOWN ARE FOR ASSEMBLY, INSTALLATION, ANCHORING & ELECTRICAL ONLY. CO FLAT PANEL TV SCALE: I /4" = I ' -0" SCALE: 1/2" = I ' -0" SCALE: 1/2" = I ' -0" SCALE: I/2" = I ' -0" 03 CUTOUT WITH INTERIOR FINISHED ELEVATION 4 ". 2'_2" 8" ELEVATION BACK SIDE 8 2' -2" 4" CUTOUT WITH INTERIOR FINISHED REMOTE RECESS POWER OUTLET 215 '9 'I ELEVATION. BANQUETTE SIDE MONOLITH 3' -2" 3 ' -2" 102 7/8" k REMOVABLE BACK PANEL ATTACH TO FRAMING WITH FINISH SCREWS AND WASHERS HALF CIRCLE BANQUETTE REFERENCE NOTES 1. FINISH COVER PLATES & RECEPTACLES IN ALL MILLWORK PIECES TO MATCH ADJACENT FINISH COLORS. MEDIA POD NOTES 1. BANQUETTE SEATING AND CONNECTING POD TABLE ARE FF &E ITEMS # 205R/205MR (205L/205ML) FURNISHED BY OWNER. DETAILS SHOWN ARE FOR ASSEMBLY, ANCHORING & ELECTRICAL ONLY. 2. MONOLITH: DUPLEX OUTLET INSTALLED W /WIRES TIED UP MOUNTING ANCHORS TO BE PROVIDED BY GC 3. MONOLITH CONFIGURED TO RECEIVE PEERLESS FLAT SCREEN MOUNT BY OTHERS. 3. ALL DIMENSIONS ARE TO BE VERIFIED IN FIELD PROIR TO PURCHASING. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISION RECEIVED SEP 22 2009 PERMIT CENTEI bOci. 1 SHEET 3380 111 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT' . ► I , , E L. ALLWINE E OF WASHINGTON ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 w 1– F- LL O O N 1� Z I.J.. O < 2 Z >- W ao Q W Q CO L�L CO 28(1) w z w U 2 F D 0 (i) w — J LJJ PROJECT -FILE 0921.02- 507 -Media Pods DRAWN BY TITLE MEDIA PODS 507 PLAN SECTION @ ARTIFACT BOX SCALE: I I /2" = I '-0" DUPLEX ELECTRICAL RECEPTACLE, TIP. 8 / VIEW OF TABLE TOP SECTION REMOVABLE BACK PANEL ATTACH TO WOOD BLOCKING WITH CONCEALED FINISH PLAN SECTION @ TABLE BASE SCREWS AND CAPS SCALE: I I /2" = I '-0" SCALE: 1 1/2" = 1 '-0" 1 X 4 AS REQUIRED FOR PLYWOOD ATTACHMENT. NOTCH AT TOP FOR STL TUBE J—BOX & ELECTRICAL WIRING TO (8) RECEPTACLES IN FLEXIBLE CONDUIT OUTLINE OF TRENCH IN CONCRETE FOR INCOMING POWER EXACT LOCATION AND POWER SOURCE TO BE VERIFIED IN FIELD SlifiKVIIIIINiaialtlatecaNIVIKOMIMMOSIOSISIKVIIMIMMRITkaailinaGNIPIPILT*" FURNITURE GRADE OUTLET ARTIFACT LM-806 (60"x 7" x 4") BY OTHERS 308 sc ALL B0 V TT IS 0 1B m LE O S F U B R O FA X CES FURNITURE GRADE OUTLET, BEYOND TUBE STL CROSSBAR SUPPORT WI STL PLATE AT PERIMETER SSM ON 3/4" PLYWOOD ON 1 1/2" STL TUBE FRAMING 13" TUBE STEEL COUNTERTOP SUPPORT FRAME 1/2 x 1/2" REVEAL, PTD. BLACK SECURE TO FLOOR WITH EPDXY FASTENERS r) N) ELEVATION SCALE: I /2" = 1 '-0" 1 1'-5" ELEVATION SCALE: 1/2" = 1 '-0" PLAN SCALE: I /2" = I '-0" 1=111=31 liyamweghw 1 EQ / - V -J 8 10" 4'-6" 6'-2" T r 2'-0" 1'-3" IME 4'-6" 1 V.I.F. C I I L T EQ _J REMOVABLE END PANEL FOR ACCESS W/ CONCEALED FASTENERS, ONE END. 306 OUTLINE OF STEEL SUPPORT STRUCTURE FURNITURE GRADE OUTLET LINE OF OUTLETS AND ARTIFACT HOUSING 308 LINE OF SUPPORT MILLWORK BASE BELOW 1 1/2" TUBE STL SUPPORTS, BELOW, POWDER COAT BLACK EDGE OF 3/4" PLYWOOD REFERENCE NOTES 1. FINISH COVER PLATES & RECEPTACLES IN ALL MILLWORK PIECES TO MATCH ADJACENT FINISH COLORS. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City ot Tukwila BUILDING DIVISION RECEIVEr SEP 22 2009 PERMIT GEN I L b009 %- 1 uJ F— U- 0 z 0 z z >- co co 0 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 REGISTERED ARCHITECT EG L. ALLWINE E OF WASHINGTON 3380 ISSUE/REVISIONS ISSUE TO HPC 08-06-09 MI PROGRESS SET 08-06-09 PERMIT SET 08-12-09 Phone 206.766.8300 Fax 206.766.8080 w z w E- D 0 w SHEET PROJECT-FILE 0921.02-508-Communal Table DRAWN BY TITLE COMMUNAL TABLE 508 V urszxas_l \ \\ \ \ \\ E \\\ Q EQ EQ \ \\ \. • \ \ \ \ \ \ \ \ \ \ \\ \\ \ \ \ \ \ \ \ \ cr) 0 ` \ \: \ • \ \ r �i \ -]_L�� 1� L\ 1�_L \\ \\ \\ , 0 \\ VERIFY W VIF hill 1c VERIFY W/ EQUIPMENT SSM BAR TOP, ON 3/4" PLYWOOD EQUIPMEN IffilirliffIMORFAMENEVATIAWIE CO cV 1/4" X 4" WIDE STEEL (STL) SUPPORT LEG CHANNEL, US10B FINISH, ANCHOR TO FLOOR AND UNDERSIDE OF BAR TOP 11/2" DIA STAINLESS STEEL RAIL W/ 1/4" STL PLATE CONNECTOR BOLTED TO STL SUPPORT, PROVIDE CONNECTIONS ON BOTH OUTSIDE FACES OF EA SUPPORT PLAM ON 3/4" PLYWOOD SUBSTRATE 1 1/2" DIA STAINLESS STEEL RAIL W/ 1/4" STL PLATE CONNECTOR BOLTED TO STL SUPPORT, PROVIDE CONNECTIONS ON BOTH OUTSIDE FACES OF EA SUPPORT 1/16" STAINLESS STEEL\ BASE 6" INTEGRAL COVE TILE BASE ELEVATION SCALE: I /2" = I ' -0" SECTION SCALE: I 1/2" = I ' -0" 1 /4 "X 2" WIDE STL SUPPORT AND LEG CHANNEL, US10B FINISH ismarratismansursiammairstaisti 9" 1/4" X 4" WIDE STL SUPPORT LEG CHANNEL, US10B FINISH, ANCHOR TO FLOOR AND UNDERSIDE OF BAR TOP BLOCKING AS REQ. 5 0 2' -0" 0 N 1 SECTION 4%" Y' SCALE: I I /2" = I' -0 11 1' -9" FRP, ON 4" CEMENT BOARD 6" TILE BASE W/ INTEGRAL COVE 1/4" CORIAN 1/2" CORIAN COUNTERTOP BEYOND 306 N, in 00 N i IIIIIIV/1111111Watswiar INTIROMINTE 308 215 N- c-I MIR. 214 L_— 0 N • 1 EXISTING STRUCTURAL COLUMNS J Li \ \\ ` \ \\ \ \\ \ \ \� \ \ \ \ \ \ \ \ \ \ \\ \ \ 00000 O u l \ 0 1 \ \\\ OF KITCHEN DEMISING WALL. EXISTING STRUCTURAL COLUMNS III 6" INTEGRAL COVE t- ( 214 TILE BASE ELEVATION SCALE: 1/2" = 1 ' -0" SEE REFERENCE NOTE #2, FOR MENU BOARD DIRECTION \ \ \ \ \\ \ \ \\� \ \\ .. \ \ \ \\ \ '\ \\\� l \ \ \ \ \\ 1 EXISTING STRUCTURAL COLUMN VERIFY W EQUIPMEN VERIFY IN FIELD COORDINATE WITH LENGTH OF KITCHEN DEMISING WALL VIF 5' -0 VERIFY W/ EQUIPMENT EXISTING STRUCTURAL COLUMN SCALE: 1/2" = 1 l'-6 8' -78" SHELF ABOVE ELEVATION PLAN SCALE: 1/2" = 1 ' -0" Il ' 1 \ 11 \ 0 I REFERENCE NOTES 1. COORDINATE FINAL EQUIPMENT SELECTIONS WITH FOOD SERVICE CONSULTANT CUTSHEETS. 2. TO ORDER MENU BOARDS, PLEASE CONTACT JACKIE DIFFENBAUGH FROM GRAPHIC SYSTEMS AT 316 - 267 -4171 3. FINISH COVER PLATES & RECEPTACLES IN ALL MILLWORK PIECES TO MATCH ADJACENT FINISH COLORS. 4. MINIMUM 3' -0" CLEAR SPACE TO BE PROVIDED BETWEEN THE FRONT BAR OPEN EDGE AND THE EDGE OF THE MEDIA POD, WALL OR NEAREST PERMANENTLY INSTALLED MILLWORK PIECE. GC TO COORDINATE AND ADJUST INSTALLATION OF THE FRONT BAR AND EQUIPMENT TO ALLOW FOR REQUIRED CLEARANCE. RE: SHEET L103 FOR INFORMATION. CRITERIA NOTES REVIEWED FOR C ODE COMPLIANCE APP OVED O CT 05 2009 C ity of Tukwila BUILDING D1n1nh1 RECEIVED SEP222009 PERMIT GENT E1 W I u_ O O NN LJ .. z 0< z >- \ W W 7 > Z N W ›- W W D 0 SHEET D03--1 111 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 REGISTERED ARCHITECT V . e - 4 E E AL WINE OF WASHINGTON 3380 ISSUE /REVISIONS MILLWORK WALLS L FOR DROP IN REFRIGERATOR MUST BE STRONG ENOUGH TO SUPPORT THE ISSUE TO HPC 08 -06 -09 TOTAL WEIGHT OF THE REFRIGERATOR AND MAXIMUM PRODUCT LOAD. MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 w z w U 2 0 C') w J F- F- w PROJECT -FILE 0921.02- 509a -S Counter DRAWN BY TITLE W co co co c tl Q a) 0 Y 0 O I — S- SERVICE COUNTER DETAILS 509a COUNTER TOP, BEYOND SSM COUNTER TOP ON 3/4" PLYWOOD, 06 SECTION SCALE: I I /2" = I ' -0" �t'iI is J ma i! r. N SECTION 14 SCALE: 1 1 /2" = 1 ' -0" cc r , , r. J =J�JfJSI�JlJ =JSJ-� 1 /2" 2' -7" r — r —� , 1 , , 1 , 1 -10 3/8" VARIES 0I VIF z 0 \\ 0 0 0 0 0 KOJ L -J ARIMMEWASM=MWAMMW S :Ommmay .___ rsJ =i —W J Jsi Ws — —PLAM ON 3/4" PLYWOOD FLAT PANEL TV, LG 26LC7D, PROVIDED BY TENANT, W/ . PEERLESS SF632 FLAT MOUNT AND WALL BRACKET. GC TO COORDINATE INSTALLATION, INCLUDING POWER, DATA AND CABLE LOCK 1 /4" ACRYLIC HINGED POCKET DOORS W/ CUSTOM PHOTOGRAPH LM -500 (2) 3' FLUORESCENT TUBE LIGHTS, VERTICAL 1/4" CLEAR ACRYLIC PANEL, WITH CUSTOM PHOTO GRAPHIC ADJUSTABLE 1/2" THK. TEMP GLASS SHELF WITH POLISHED EDGES, RESTING ON S.S. 3/16 "0 X 1" DOWEL PINS 18 GA STAINLESS STEEL COUNTER 1 J GRAB -N -GO KITCHEN EQUIPMENT W/ GLASS SHELVING (SEE. SPEC FOR CUTOUT DIMENSIONS) MILLWORK WALLS (ON EACH SIDE OF UNIT) FRP ON 1" CEMENT BOARD PLAM ON 3/4 ". PLYWOOD SUBSTRATE, PLAM BASE ON 1/4" PLYWOOD, BLOCKING AS REQ. I-1/2" SECTION 1' -3" SCALE: I I /2" = I' -O" frOliitairliffiMIEVIFIBECNEMEIEWBANOWESIEVIEEKINN 1 5" SECT ON SCALE: I I /2" = I' -0" -10 5/8"± FRP, !'L'O ON 1 /2" CEMENT BOARD O ;0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 O 0 0 .0: 0 0 0 0 0 O 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 214 • VARIES SEE PLANS 6" TILE BASE W/ INTEGRAL COVE. C) 0 i M N N CO 13095 PLAM ON 3/4" PLYWOOD PLAM ON 3/4" PLYWOOD SSM BAR TOP, ON i" PLYWOOD, 306 PLAM ON 3/4" PLYWOOD 389 PLAM ON 3/4" PLYWOOD (39 SSM BACKSPLASH FOOD SERVICE EQUIP. G.C. TO COORDINATE INSTALL. 1 J 18 GA STAINLESS STEEL COUNTER VARIES SEE PLANS SECTION •'l,i/ /Sl =1 ■1 1 =1 —/Sl /2M lips ILIIII� l i b - : ❑ I I I I PLAM ON 3/4" PLYWOOD PLAM ON 3/4" PLYWOOD SSM BACKSPLASH STAINLESS STEEL SHELF, ITEM 207 18 GA STAINLESS STEEL 2' -8" COUNTER EPCO, DP41 3" ALUMINUM PULL BLACK MELAMINE INTERIOR PLAM CABINET FRONT 3/4" BLACK MELAMINE ADJUST. SHELVING EDGE BANDED PLAM BASE ON 1/4" PLYWOOD, CO cc L SCALE: I I /2" = I' -0" SECTION SCALE: 1 I /2" = 1 ' -0" n REFERENCE NOTES COORDINATE FINAL EQUIPMENT SELECTIONS WITH FOOD SERVICE CONSULTANT CUTSHEETS. TO ORDER MENU BOARDS, PLEASE CONTACT JACKIE DIFFENBAUGH FROM GRAPHIC SYSTEMS AT 316 - 267 -4171. CRITERIA NOTES MILLWORK WALLS FOR DROP IN REFRIGERATOR MUST BE STRONG ENOUGH TO SUPPORT THE TOTAL WEIGHT OF THE REFRIGERATOR AND MAXIMUM PRODUCT LOAD. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 5 2009 City of Tukwila BUILDING DIVISIfm RECEIVED SCP 22 2009 PERMIT CENTEF X69 - 197 111 Greg L. Allwine ARCHITECT 15200 52nd Avenue South Suite 200 Seattle, WA 98188 Phone 206.766.8300 Fax 206.766.8080 TE OF WASHINGTON 3380 REGISTEREI3 ARCHITECT` ISSUE /REVISIONS ISSUE TO HPC 08 -06 -09 MI PROGRESS SET 08 -06 -09 PERMIT SET 08 -12 -09 SHEET PROJECT -FILE 0921.02 509b - S Counter Sections DRAWN BY TITLE S- SERVICE COUNTER SECTIONS 509b