Loading...
HomeMy WebLinkAboutPermit D09-217 - WESTFIELD SOUTHCENTER MALL - VANILLA SHELLVANILLA SHELL 1149 SOUTHCENTER MALL D09 -217 Parcel No.: 6364200010 Address: 1149 SOUTHCENTER MALL TUKW Suite No: Tenant: Name: VANILLA SHELL Address: 1149 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC BSIP Address: TOTAL 13 PARCEL NUMBERS , 2010 NEW PLAT MAJOR 920247 00000 Phone: Contact Person: Name: STEVE FOUST Address: 2350 25 DR SE , BOTHELL WA 98021 Phone: 206 - 856 -1247 Contractor: Name: SG FOUST CONSTRUCTION INC Address: 23502 25TH DR SE , BOTHELL WA 98021 Phone: 425 - 483 -9414 Contractor License No: SGFOUGF911KJ Cityef Tukwila r Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us DEVELOPMENT PERMIT Permit Number: D09 -217 Issue Date: 10/28/2009 Permit Expires On: 04/26/2010 Expiration Date: 05/11/2011 DESCRIPTION OF WORK: ADD NEW STOREFRONT, BUILD ONE STOREROOM WALL 20 GUAGE 2 X 6 5/8 17 FEET TO PAN DECKING ABOVE. ADD ONE VAV BOX WITH TEO DIFFUSERS, ADD 200 SQUARE FEET OF HARD LID AT ENTRY Value of Construction: $42,980.00 Fees Collected: $1,344.96 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: 0019 doc: IBC -10/06 * *continued on next page ** D09 -217 Printed: 10 -28 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: City oilTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila. wa. us N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Permit Number: DO9 - 217 Issue Date: 10/28/2009 Permit Expires On: 04/26/2010 End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Print Name: doc: IBC - 10/06 ZV N Date: 10 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the rf• arm K work. I am authorized to sign and obtain this development permit. Signatur . Date. / 2 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -217 Printed: 10 -28 -2009 Parcel No.: 6364200010 Address: 1149 SOUTHCENTER MALL TUKW Suite No: Tenant: VANILLA SHELL 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D09 -217 Status: ISSUED Applied Date: 10/12/2009 Issue Date: 10/28/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 D09 -217 Printed: 10 -28 -2009 14: ** *FIRE DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Gates serving the means of egress system shall comply with the requirements of the International Fire Code. Gates used as a component in a means of egress shall conform to the applicable requirements for doors. (IFC 1008.2) 25: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 26: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 27: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) doc: Cond -10/06 D09 -217 Printed: 10 -28 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us 28: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051.(All fire alarm components to be tied to the main mall fire alarm panel.) 29: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 33: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1)(Post address on storefront per approved Westfield standards.) 34: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 35: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 36: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * * continued on next page ** D09 -217 Printed: 10 -28 -2009 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature Print Name: �� ? ✓✓� �� -�� doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Dat/ D09 -217 Printed: 10 -28 -2009 SITE LOCATION Site Addre Southcenter,PerrMar Tenant Name: Westfield Vanilla Shell Property Owners Name: Westfield LLC> Mailing Address: Same CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Steve Foust CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.its Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 1149 Mt II E -Mail Address: stevefoust @sgfoust.com SG Foust Construction Inc. Contact Person: Steve Foust E -Mail Address: stevefoust @sgfoust.com Contractor Registration Number: SGFOUGF911 KJ Building Permit No. Do`7-- Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No Project No (For office use only) King Co Assessor's Tax No.: (P,�10 'Qd Suite Number: 1,410 Floor: 1 New Tenant: m Yes ❑..No City State Day Telephone: (206) 856 -1247 Zip Mailing Address: 23502 25th DR SE Bothell WA 98021 City State Fax Number: (425) 877 -1784 City State Day Telephone: (425) 877 -1784 Fax Number: (425) 877 -1786 Expiration Date: 05/11/2011 State Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: 23502 25th DR SE Bothell WA 98021 Zip ARCHITECT OF RECORD All plans must be wet stamped by Architect of Record Company Name: Mailing Address: cit Day Telephone: Fax Number: Zip Contact Person: E -Mail Address: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Rec ord Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applications \Fortes- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page I of6 BUILDING PERMIT INFOR1V ATION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 42,98 Existing Building Valuation: $ Scope of Work (please provide detailed information): Add new storefront, build one storeroom wall 20 gauge 2X6 5/8 17 feet to pan decking above. Add one VAV box with two diffusers, add 200 square feet of hard lid at entry. Add one 1041 Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: m Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? If 'Yes', attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh m.. No If yes, a separate permit and plan submittal will be required. ❑ Yes ❑ No Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l Floor 612 2 °" Floor 3' Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFOR1V ATION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 42,98 Existing Building Valuation: $ Scope of Work (please provide detailed information): Add new storefront, build one storeroom wall 20 gauge 2X6 5/8 17 feet to pan decking above. Add one VAV box with two diffusers, add 200 square feet of hard lid at entry. Add one 1041 Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: m Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? If 'Yes', attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh m.. No If yes, a separate permit and plan submittal will be required. ❑ Yes ❑ No Page 2 of 6 Mailing Address: PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signatur Print Name: Date Application Accepted: IZED AGENT: Date Application Expires: ti 1 0 - ' -0 9 H:\Applications\Porms- Apphcanons On Line \2009 Applications \1 -2009 - Permit Apphcatton.doc Revised: 1.2009 bh City Date: /O ./ 1-- A � Day Telephone: 2 —rt _j (-/2 y7 State Staff Initials: Zip Page 6 of 6 Parcel No.: 6364200010 Permit Number: D09 -217 Address: 1149 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 10/12/2009 Applicant: VANILLA SHELL Issue Date: Receipt No.: R09 -01694 Initials: User ID: WER 1655 Payee: SG FOUST CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10048 816.90 Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Payment Amount: $816.90 Account Code Current Pmts 000.322.100 812.40 640.237.114 4.50 Total: $816.90 Payment Date: 10/28/2009 01:38 PM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 10 -28 -2009 Receipt No.: R09 -01581 Payee: SG FOUST CONSTRUCTION ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10033 528.06 Authorization No. RECEIPT Parcel No.: 6364200010 Permit Number: D09 -217 Address: 1149 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 10/12/2009 Applicant: VANILLA SHELL Issue Date: Payment Amount: $528.06 Initials: WER Payment Date: 10/12/2009 02:27 PM User ID: 1655 Balance: $816.90 Account Code Current Pmts 000/345.830 528.06 Total: $528.06 PAYMENT RECEIVED doc: Receipt-06 Printed: 10 -12 -2009 Project: j //'/J V/ ZIA SdP(l Type of Ins ection: t 4 f Address: ✓/ 4/q S( ft744!/ Date Called: Special Instructions: Date Wantgd: of 5 a.m. p.m. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: ) t.A-Z/ 4Jt — 4 tVeivc '-<" — 'V/4 C spec r: INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. 60. ' ' REINSPEC ON FEE SQUIRED. Prior to inspection, fee must be pa at 6300 South -nter Blv Suite 100. Call to schedule reinspection. pt No.: (Date: PERMIT NO. (206)431 -3670 Project; _ i i Type of Inspection: Address: // Vc . //4 'A - lg., Date Called: f( Special Instructions: eWd Date Wanted: /2 / 2 A Of - Vim• Requester: Phone No: _ �y (S —.`� 7O ` l 3 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 U Approved per applicable codes. COMMENTS: 6 ;p /.n i< S./err r _ ,4/ t/V Inspect f 0.00 REINSP CTIQN FEE R UIRED. Prior to in fee must be pr o at 6300 So thcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: , Date: i PERMIT NO. (206)431 -3670 R Corrections required prior to approval. COMMENTS: Type of nspecti D , 4 t 1 4M_/ / 7:7;1216 1/ 1 Vx+ 6cc'l ! !'fi t ' deich 4 D. d: Alla f*—/ 0 c) , ),{ -- 4!6 Special Instructions: Date Wanted: /I - V I - — ( P.m. Requester: Phone No: f / i -- s5 4, -_ 12-4 Project: - i C.-/k S � I Type of nspecti l Address Sc J �, Date Called: Special Instructions: Date Wanted: /I - V I - — ( P.m. Requester: Phone No: f / i -- s5 4, -_ 12-4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 ❑ Approved per applicable codes. Inspec Date: / / V-/ .00 REINSPECTI0 FEE R UIRED.1 to inspection, fee Est be id at 6300 Southcenter Blvd.,lSuite 100 Call to schedule reinspection. Rec ipt No.: 'Date: Corrections required prior to approval. g. Project 0 14 t 1 Type of Inspection: A { Address �P ate Called: Special Instructions: Date Wanted: 0 +�. - p.m. Request et: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit LPN/7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: a144 /S7 2� 4/0/.1.41 / 4 { ( D $60.0 INSPECTI0 FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: pe per' • T of Ind 1E . o FA F.% -1 1 Address: / i ,../ / S c M ci / / Suite #: Contact Person: R ay Special Instructions: Phone No.: a-co l; - G a-.1- s c ),-... Needs Shift Insbection: `f Sprinklers: Fire Alarm: y' Hood & Duct: Monitor: 6 --s-e, Wu{ i u 1-, Pre -Fire: Permits: Occupancy Type: M INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit DO O9 -110 CITY OF TUKWILA `FIRE DEPARTMENT 444 Andover Park East . Tukwila, Wa. 98188 206 -57 1 Approved per applicable codes. Word/Inspection Record Form.-Doc 1/13/06 n Corrections regubed prior to approval. T ENTS: F F; tIcA 1 01< tfpct, F; lict I 0 Fie -e F01,, ! o1 Inspector: ) I : I Hrs.. $80.00 REINSPEC ION FEE REQUIRED. You will receive an invoice from the City of Tukwila finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: rA Type of Inspection: A"; ;--t... ;--t... .. 4l4.4 .4./ jz�g f Address: / /'-/ 9 S c r a4, / Suite #: Contact Person: A & Duct: S pecial Instructions: Phone No.: 204 . ZZ. ..5 - — - ,: Needs Shift Inspection: Sprinklers: Fire Alarm: F ood & Duct: Monitor: Pre -Fire: Permits: _ Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY t ' K I A FIRE DEPARTMENT 444 Andover Park East Tu Wa. 98188 206 5 • n Approved per applicable codes. 1/13/06 Word /Inspection Record Form.Doc 0v9._ 2'1 PERMIT NUMBERS - - Q7 113 . C °- o ° r . rections required prior to approval. COMMENTS: ig�� c t r '1 s Inspector: Hrs.: 7 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 ACTIVITY NUMBER : DO9 217 PROJECT SHEL SITE ADDRESS: 1149 SCOT GEN, . X Original Plan Submittal Response to Incomplete Letter #� Response to Correction Letter # Revision # After Permit Issued DATE: 10- 12 - DEP RTMENTS:, B �-- ii thing ision Pu'6'lic` WoWs �I DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -13 -09 Complete PLAN REVIEW /ROUTING SLIP Structural Incomplete Comments: INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route NI Structural Review Required 0 ewL re Prevention C n thik 1 Planning Division Permit Coordinator Not Applicable No further Review Required C REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 DUE DATE: 11-10-09 Not Approved (attach comments) LI License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FOUSTA1064J2 FOUST a ASSOCIATES INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 4/22/1994 3/28/1998 ARCHIVED Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC 512860 05/06/2009 Until Cancelled 05/11/2009 $12,000.00 05/11/2009 Name Role Effective Date Expiration Date FOUST, STEPHEN GREGORY AGENT 05/11/2009 FOUST, STEPHEN GREGORY PRESIDENT 05/11/2009 FOUST, KERRI JUNE SECRETARY 05/11/2009 Untitled Page Other Associated Licenses • • General /Specialty Contractor A business registered as a construction contractor with LFtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company SG FOUST CONSTRUCTION INC 4254839414 23502 25th DR SE BOTHELL WA 98021 SNOHOMISH Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602922219 ACTIVE SGFOUGF911 KJ CONSTRUCTION CONTRACTOR 5/11/2009 5/11/2011 GENERAL UNUSED Page 1 of 2 Business Owner Information Bond Information https://fortress.wa.gov/lni/bbip/Detail.aspx 10/28/2009 WESTFIELD MALL AT SOUTHCENTER Code Summary CODE SUMMARY: 18C 2006 - INCLUDING WASHINGTON STATE AMENDMENTS FULLY SPRINKLED BUILDING - TO BE SUBMITTED UNDER SEPARATE PERMIT. MECHANICAL DESIGN - TO SE SUBMITTED UNDER SEPARATE PERMIT ELECTRICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT PLUMBING DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT. PERMIT TYPE - TENANT IMPROVEMENT AT EXISTING COVERED MALL BUILDING SITE INFORMATION: TENANT SPACE *1410 ADDRESS: 1149 SOUTHCENTER TUKWILA, WA 98188 TAX PARCEL NUMBER 262304 -9023 ZONING USE: TUC - TUKUJILA URBAN CENTER TENANT IMPROVEMENT SUMMARY: TOTAL SQUARE FEET: 815 SF OCCUPANCY GROUP: WESTFIELD MALL - M - COVERED MALL OCCUPANCY LOAD: OCCUPANT LOAD FACTOR- 100 5.F. PER OCCUPANT TOTAL S.F. OF SPACE- 815 SR OCCUPANT LOAD- 9 - OCCUPANT LOAD 1=GRE55 REQUIREMENTS: EGRESS WIDTH - 1 (.15) = 1.05 - THEREFORE DOORS NOT LESS THAN 32" CLEAR WIDTH - 3' -0" x 1' -0" ACCEPTABLE. PER TABLE 1015.1 THE MAXIMUM OCCUPANT LOAD FOR ONE EXiT WiTHIN OCCUPANCY TYPE 'M' IS 49. (TABLE 1015.1) MINIMUM CORRIDOR WIDTH OF 44" - PROVIDED THEREFORE ACCEPTABLE FIRE RESISTANCE REQUIREMENTS: CORRIDORS NOT REQUIRED TO BE 1 -HOUR RATED PER TABLE 1011.1 FOR FULLY SPRINKLERS BUILDING IN OCCUPANCY TYPE B. DOORWAYS TO EXITS PASSAGEWAYS SHALL BE PROTECTED BY 1 -HOUR FIRE DOOR ASSEMBLY THAT INCLUDES SELF CLOSING DEVICE. - SECTiON 402 45.I EACH TENANT SHALL BE SEPARATED BY A FIRE PARTITION IN ACCORDANCE TO SECTION 108. CONTRACTOR SHALL COORDINATE WITH BUILDING INSPECTOR FOR STAGGERING OF GYPSUM WALL BOARD ON TENANT DEMISING WALLS THAT HAVE PREVIOUSLY RECIEVED GYPSUM WALL BOARD ON ADJACENT TENANTS DEMISING WALL PLUMBING REQUIREMENTS (TABLE 2902.1) SECTION 29022 EXCEPTION i'2: SEPARATE FACILITIES SHALL NOT BE REQIURED FOR TENANT SPACES WITH A TOTAL OCCUPANT LOAD, INCLUDING BOTH EMPLOYEES AND CUSTOMERS, OF 5 OR LESS. OCCUPANT LOAD IS 1 THEREFORE OK Separate Permits THE FOLLOWING ITEMS SHALL BE UNDER SEPARATE PERMIT: FiRE ALARM, FiRE SPRINKLER SIGNAGE, MECHANICAL, ELECTRICAL, AND PLUMBING SHALL BE UNDER SEPARATE PERMIT TO BE SUBMITTED BY CONTRACTOR CE General Notes 1. ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK 2. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK ANY DISCREPANCIES, ERRORS OR OMISSIONS TO SE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. 3. THE ARCHITECT WILL HAVE A REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SITE VISITS TO OBSERVE THE CONSTRUCTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN RESOLVING VARIATIONS IN THE EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL KNOWN CONDITIONS, BUT IT IS ANTICIPATED THAT HIDDEN CONDITIONS WILL BE ENCOUNTERED DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGES. 4. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES TRUE, LEVEL, PLUMB AND SQUARE. 5. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. POSTED DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. 6. ALL ATTACHMENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO ASSIST THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL. 1. DETAILS SHOWN IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR SHOWN. DETAILS OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE OF THE SAME NATURE AS THOSE DRAWN FOR SIMILAR CONDITIONS. S CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO REPLACE IN KiND ANY SUCH ITEMS DAMAGED, iN ITS ENTIRETY TO LEVEL OF SATISFACTION OF ARCHITECT. 9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER, INCLUDING: SITE ACCESS, MATERIALS STORAGE AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO VERIFY SEQUENCE OF WORK WiTH OWNER 10. ALL INTERIOR GWB iS i" TYPE X ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. SEE NOTE FOR WATER RESISTANT GWB. 11. PROVIDE WATER RESISTANT (PAPERLESS) TYPE X GWB IN ALL TOILET ROOMS, WAREWASH AND WET AREAS. 12. PROVIDE FINISH WALL BEHIND ALL EQUIPMENT AND CASEWORK 13. PROVIDE ALL ACCESSIBLE SiGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION. 14. PROVIDE ONE TYPE 5E -2A -10130 FIRE EXTINGUISHER PER 3000 SF AND NOT MORE THAN 15 FT OF TRAVEL DISTANCE, 15. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT AT NONRATED PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATES PARTITIONS. 16. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL SE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND /OR ACOUSTICAL ISOLATION OF SPACES WiTH APPROPRIATE FIRE STOP MATERIAL. 11. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. 15 FURNISH AND INSTALL THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTORS SHALL OBTAIN ALL NECESSARY PERMITS. 19. INSTALL FiRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 20.FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS. 2L PROVIDE FINISH FLOOR UNDER ALL EQUIPMENT AND CASEWORK Scope of Work SCOPE OF WORK SHALL INCLUDED THE S15 SF. TENANT IMPROVEMENT TO VACANT SPACE 1410 WITHIN THE WESTFIELD MALL AT SOUTHCENTER THE WORK WILL COMPRISE OF THE CONSTRUCTION OF NEW COMMON MALL STOREFRONT, CEILING, AND TENANT STOCK AREA 'IN SACK OF SPACE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIRING DESIGN BUILD PROFESSIONALS FOR ALL ASSOCIATED MECHANICAL, ELECTRICAL, FIRE SPRINKLER, AND FIRE ALARM FOR THiS TENANT IMPROVEMENT. Drawing Index ARCHITECTURAL T1.0 TITLE - COVER SHEET A1.0 FLOOR PLAN, RCP, AND SECTIONS A2.0 STOREFRONT ELEVATIONS AND DETAILS Vicinity Map Project Directory WEA SOUTHCENTER, LLC 633 Southcenter Seattle, WA 98188 SENIOR GENERAL MANAGER ANDREW CIARROCHI T - 206246.0423 F - 2062440601 WESTFIELD SPECIAL PROJECTS GROUP ARCHITECTURAL PROJECT MANAGER GERRI GAFNEY 11601 WILSHIRE BLVD. 9TH FLOOR LOS ANGELES, CA 90025 T - 310.6895694 F - 310.689.1289 GGAFFNEY.WESTFIELD.COM MALL OPERATIONS: PAT BURNS T - 2062460423 F - 206244.8601 C - 206.1869011 PBURNSGWESTFIELD.COM ARCHITECT S.M. STEMPER ARCHITECTS, P.L.L.C. 4000 Delridge Way SW Suite 200 Seattle, Washington 98106 CONTACT: WAYNE JOHNSON, PROJECT MANAGER (206) 624 -2111 (206) 624 -2913 FAX waynelDsmstem er.com E CM Permit Nos t i f : , REVISIONS No changes shall be ae mm de to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: gf ebbanteal atrtoal I tumbing City of 'Mae BUILDING DIVISION Site Plan MEI IPIIPP NORDSTROM J 3 LEVELS TENANT SPACE 1410 SOUTHCENTER MALL CODE COMPLIANCE APPROVED OCT 27 2009 ks- City of Tukwila 14 BUILDING DIVISION mer'vyivs 2 LEVELS i(�ExIS11 G 3 -_' LEVaS "J 3 LEVELS . bO 217 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAY NC IS AN INSTRUMENT OF SERNCE. IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERMISSION MD UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S NAME. AU. DESIGN AND OTRER NFORMARON SHOTIN ON THE WANING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WiTHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 624 -2777 • FAX (206) 624 -2973 ISSUE ISSUE DATE: F- z c w w 0 0 2 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ PERMIT SET OCT. 8, 2009 TITLE - COVER SHEET RECEIVED OCT 12 2009 PERMIT CENTER T1.0 SMSA #0923.01 DOOR NO ROOM LOCATION DOOR TYPE DOOR STYLE SIZE W x H THK. DOOR MATL. HM FR. TYPE FRAME MATL. RATING DETAILS HDWR GROUP NOTES FIRST FLOOR HEAD JAMB THRESH �m dm ` •(E) • • • . • • • METAL STUD- • FRAMING AND GWB :: • STOCK . •. ROOM . RETAIL AREA - STOCK ROOM COMMON MALL - RETAIL AREA BIFOLD 3' -0" x 1' -0" 13/4" WD HM. NR 10/A2.0 9/42.0 SIM 6/4W 2 1 GLASS PR 3' -0" x 10' -0" 1/2" GLASS AL N.R. 1/42.0 4/A20 6/A2.0 1 2,3 \ \ \\ _ II 9 i •. ... 100 1 • N . .I 101 1 .. REMARKS 1: HOLLOW METAL FRAME TO BE PRIMED FOR PAINT UNLESS NOTED OTHERWISE 2: FURNISH AND INSTALL THRESHHOLD AT TRANSITION OF FLOOR MATERIAL 3. GLASS DOORS SHALL BE CLEAR FULLY TEMPERED SAFETY GLASS MEETING ALL REQUIREMENTS FOR GLASS DOORS INCLUDED ADJACENT BORROWED LITES. PANEL (E) METAL STUD -�1 AND GUS TENANT DEMISING WALL (E) ELECT. ADJACENT TENANT AL FL FR HM NR STOR WD SPACE I_, BACK OF HOUSE CORRIDOR STOCK I I - 0 " ALUMINUM FLUSH DOOR FRAME HOLLOW METAL NON -RATED STOREFRONT DOOR WOOD FLOOR PLAN 1/4" = 1' -0" SECTION 1/4" = 1' -0" RETAIL R ABBREVIATIONS NOTES TO DOOR TYPES NOTES TO FRAME TYPES =11111■MIIINNIMEMIII• 111•11111 1111••■ 4111•0 31' -1 3/4" 1. SEE SCHEDULE AND SPECIFICATIONS FOR HARDWARE, GASKETING, AND SEALS PER HARDWARE GROUP. 2. SEE SCHEDULE FOR FIRE RATING. 3. THRESHOLDS TO BE 1/2" HIGH MAX. (TYP.) 4. PROVIDE LEVER TYPE HANDLES, MOUNTED AT 38" AFF. AT SPACES SCHEDULED TO BE ACCESSIBLE PER ADA CODE, TYP. 1. ALL DIMENSIONS TO BE VERIFIED IN FIELD BY CONTRACTOR. 41' -9" 4' -0" EXISTING GQNCRETE SLAB OUTLINE OF — SOFFIT ABOVE 0111111, ONO .100 OIM al1111•111 (E) CONCRETE ON METAL DECK (E) CONCRETE SLAB HARDWARE GROUPS GROUP 1 - GLASS DOOR 100 2 QTY. OVERHEAD CONCEALED CLOSER 2 FRS. 1" DIA. 18" BACK TO BACK PULLS 2 QTY. DEAD BOLT FLOOR RAIL LOCK 2 QTY. CYLINDER GROUP 2 - STOCK ROOM DOOR 101 3 QTY. HINGES I QTY. LATCI4SET QTY. WALL STOP 3 QTY. SILENCERS (E) METAL STUD AND GUS TENANT DEMISING WALL 8 - 0 " 4' -10 1/4" MALL COMMON AREA 0 (E) MALL BULKHEAD AND CEILING ALL BULKHEAD AFF METAL STUD FRAMING AND GUS BULKHEAD TENANT STOREFRONT MALL COMMON AREA IRST LEVEL FF 0' -0" INTERIOR GLAZING TYPES FG -I TG -1 CLEAR FLOAT GLASS CLEAR TEMPERED GLASS TO STRRUCTURE — 1A00 7.� ----- ----- 7.e1• RETAIL AREA •. GWB I2'_P . 4' -0" STRIP LIGHT FIXTURES RE: ELECTRICAL (E) METAL STUD AND GUS TENANT DEMISING WALL ADJACENT TENANT SPACE FRAMING - AND .0.4. • 'STOCK _ROOM 101 Anob METAL STUD . FRAMING AND GWB (E) BACK OF HOUSE CORRIDOR REFLECTED CEILING PLAN 1/4" = 1' -0" • SECTION 1/4" = 1' -0" • • .RETAIL 11001 (E) METAL STUD AND GWB TENANT DEMISING WALL (E) CONCRETE ON METAL DECK METAL STUD FRAMING AT BULKHEAD SUSPENDED ) GU/13 CEILING (E) CONCRETE SLAB 1 CEILING MALL COMMON AREA (E) MALL BULKHEAD TENANT STOREFRONT MALL COMMON AREA FIRST LEVEL FF 4 0' 0" MALLBULKHEAD 13' -6" AFF NOTES ■ CONTRACTOR SHALL VERIFY STATUS OF (E) GWB WITHIN TENANT SPACE AND INSTALL GUS AT LOCATIONS REQUIRED TO MAINTAIN I -HOUR RATED ASSEMBLY PER WALL TYPE MD TENANT DEMISING WALL CRITERIA AT ALL ELECTRICAL FIXTURES INCLUDING BUT NOT LIMITED TO, ELECTRICAL PANELS, LIGHTING, SWITCHES ARE SHOWN FOR REFERENCE ONLY AND SHALL BE COORDINATED WITH ELECTRICAL PERMIT AND REQUIREMENTS. GLASS TENANT STOREFRONT SHALL MEET OR EXCEED ALL ADA EGRESS REQUIREMENTS SET FORTH BY FEDERAL, STATE, AND LOCAL JURISDICTIONS HAVING AUTHORITY CONTRACTOR SHALL DEMOLISH EXISTING GWB AND METAL STUD FRAMING IN ITS ENTIRETY FOR NEW TENANT STOREFRONT NOTES: 1. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. WALL TYPES SHALL EXTEND UP TO BOTTOM OF SUSPENDED CEILING TILES UNLESS NOTED OTHERWISE IN WALL TYPES. • 3. EXISTING WALLS ADJACENT TO TENANT SPACE SHALL REMAIN- LEAVING MN. 6" GAP AT TOP OF WALL FOR PROPER PLENUM AIR FROM FINISH WALL PER FINISH.SCHEDULE. 4. DATA /ELECTRICAL ARE SI40UN FOR REFERENCE ONLY. ELECTRICAL DESIGN SHALL BE SUBMITTED BY CONTRACTOR AND PERMITTED UNDER SEPARATE PERMIT. 5. ALL MATERIALS SHALL BE NON - COMBUSTIBLE AND /OR SHALL COMPLY WITH THE REQUIRED FLAME SPREAD OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION. ALSO ANY WOOD COMPONENTS USED SHALL BE FIRE RETARDENT TREATED WOOD. (IBC 402.15.4, 602, 603, 4 2604) 6. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AS WELL AS LEASE LINE6 J PRIOR TO COINSTRJCTIOTI A%lY tESCREPENCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFIELD FOR CLARIFICATION. 1. CONTRACTOR SHALL PROTECT MALL.' COMMON AREA AT ALL TIMES AND NO CONSTRUCTION MATERIAL, DEBRIS, WORK, OR DUST SHALL ENTER OR BE WITHIN MALL COMMON AREA. D REVIEWED FOR CODE COMPLIANCE PPROVED OCT 2 7 2009 City of Tukwila BUILDING DIVISION WALL TYPES WALL TYPE 1 (NON- RATED) - 5/8" TYPE X GWB - 3 D" STL. FRAMING AT 16" 0.C. - 5 /S" TYPE X GUS 2 WALL TYPE 2 (1 -HR RATED) UL DESIGN + U -465 - EXISTING 5/8" TYPE X GUS - EXISTING 6" STL. FRAMING AT 16" O.C. - EXISTING 5/8" TYPE X GWB - WALL SHALL CONTINUE UP TO STRUCTURE WI GWB STOPPING 6" FROM STRUCTURE NOTE WALL TYPE +2 - CONTRACTOR SHALL VERIFY THE STATUS OF GWB WITHIN TENANT SPACE TO MEET MEET I -HR RATED ASSEMBLY REQUIREMENT. 3 WALL TYPE 1 (NON- RATED) 0 - 3 " STL. FRAMING AT 16" D.C. - 5/8" TYPE X GWB 4 WALL TYPE 2 (1 -HR RATED) UL DESIGN • U -465 - EXISTING 5/8" TYPE X GUS - EXISTING 6" STL. FRAMING AT 16" OTC. - EXISTING 5/8" TYPE X GWB - WALL SHALL CONTINUE UP TO STRUCTURE WI GUS STOPPING 6" FROM STRUCTURE NOTE WALL TYPE +2 - CONTRACTOR SHALL VERIFY THE STATUS OF GUS WITHIN TENANT SPACE TO MEET MEET 1 -HR RATED ASSEMBLY REQUIREMENT. RECEIVEr OCT 12 2009 PERMIT CENTt ISSUE ISSUE DATE: 633 Sacthcenter P nicway Yhkwt4 WA.. 98188 -2668 206 -246-0423 I- - z 0 w w F- z z z w F- WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAVANG IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRWUCRON CARRIES THE ARCHITECTS NAME. ALL DESIGN AND OTHER INFORMATION THOeN ON THE CRANING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional limited Liability Company 4000 DELRIDGE WAY SW MILLS 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 (: co w w U < 0J PERMIT SET OCT. 8, 2009 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ FLOOR PLAN RCP AND SECTIONS A1.0 SMSA #0923 WESTFIELD MALL AT SOUTHCENTER ` •(E) • • • . • • • METAL STUD- • FRAMING AND GWB :: • STOCK . •. ROOM . QUSPENDED)" METAL STL AT GJJB D FRAMNG BULKHEAD CEILING e a Ili a e a e a • - METAL STUD : FRAMING AND . '- . GUS :.- • RETAIL- -. : - • AREA • • 0 . . . ' •:.:: ,. - • e 1. \ 119-,fi1 L • \ \ \\ _ II 9 i •. ... 100 1 • N . .I 101 1 .. PANEL (E) METAL STUD -�1 AND GUS TENANT DEMISING WALL (E) ELECT. ADJACENT TENANT AL FL FR HM NR STOR WD SPACE I_, BACK OF HOUSE CORRIDOR STOCK I I - 0 " ALUMINUM FLUSH DOOR FRAME HOLLOW METAL NON -RATED STOREFRONT DOOR WOOD FLOOR PLAN 1/4" = 1' -0" SECTION 1/4" = 1' -0" RETAIL R ABBREVIATIONS NOTES TO DOOR TYPES NOTES TO FRAME TYPES =11111■MIIINNIMEMIII• 111•11111 1111••■ 4111•0 31' -1 3/4" 1. SEE SCHEDULE AND SPECIFICATIONS FOR HARDWARE, GASKETING, AND SEALS PER HARDWARE GROUP. 2. SEE SCHEDULE FOR FIRE RATING. 3. THRESHOLDS TO BE 1/2" HIGH MAX. (TYP.) 4. PROVIDE LEVER TYPE HANDLES, MOUNTED AT 38" AFF. AT SPACES SCHEDULED TO BE ACCESSIBLE PER ADA CODE, TYP. 1. ALL DIMENSIONS TO BE VERIFIED IN FIELD BY CONTRACTOR. 41' -9" 4' -0" EXISTING GQNCRETE SLAB OUTLINE OF — SOFFIT ABOVE 0111111, ONO .100 OIM al1111•111 (E) CONCRETE ON METAL DECK (E) CONCRETE SLAB HARDWARE GROUPS GROUP 1 - GLASS DOOR 100 2 QTY. OVERHEAD CONCEALED CLOSER 2 FRS. 1" DIA. 18" BACK TO BACK PULLS 2 QTY. DEAD BOLT FLOOR RAIL LOCK 2 QTY. CYLINDER GROUP 2 - STOCK ROOM DOOR 101 3 QTY. HINGES I QTY. LATCI4SET QTY. WALL STOP 3 QTY. SILENCERS (E) METAL STUD AND GUS TENANT DEMISING WALL 8 - 0 " 4' -10 1/4" MALL COMMON AREA 0 (E) MALL BULKHEAD AND CEILING ALL BULKHEAD AFF METAL STUD FRAMING AND GUS BULKHEAD TENANT STOREFRONT MALL COMMON AREA IRST LEVEL FF 0' -0" INTERIOR GLAZING TYPES FG -I TG -1 CLEAR FLOAT GLASS CLEAR TEMPERED GLASS TO STRRUCTURE — 1A00 7.� ----- ----- 7.e1• RETAIL AREA •. GWB I2'_P . 4' -0" STRIP LIGHT FIXTURES RE: ELECTRICAL (E) METAL STUD AND GUS TENANT DEMISING WALL ADJACENT TENANT SPACE FRAMING - AND .0.4. • 'STOCK _ROOM 101 Anob METAL STUD . FRAMING AND GWB (E) BACK OF HOUSE CORRIDOR REFLECTED CEILING PLAN 1/4" = 1' -0" • SECTION 1/4" = 1' -0" • • .RETAIL 11001 (E) METAL STUD AND GWB TENANT DEMISING WALL (E) CONCRETE ON METAL DECK METAL STUD FRAMING AT BULKHEAD SUSPENDED ) GU/13 CEILING (E) CONCRETE SLAB 1 CEILING MALL COMMON AREA (E) MALL BULKHEAD TENANT STOREFRONT MALL COMMON AREA FIRST LEVEL FF 4 0' 0" MALLBULKHEAD 13' -6" AFF NOTES ■ CONTRACTOR SHALL VERIFY STATUS OF (E) GWB WITHIN TENANT SPACE AND INSTALL GUS AT LOCATIONS REQUIRED TO MAINTAIN I -HOUR RATED ASSEMBLY PER WALL TYPE MD TENANT DEMISING WALL CRITERIA AT ALL ELECTRICAL FIXTURES INCLUDING BUT NOT LIMITED TO, ELECTRICAL PANELS, LIGHTING, SWITCHES ARE SHOWN FOR REFERENCE ONLY AND SHALL BE COORDINATED WITH ELECTRICAL PERMIT AND REQUIREMENTS. GLASS TENANT STOREFRONT SHALL MEET OR EXCEED ALL ADA EGRESS REQUIREMENTS SET FORTH BY FEDERAL, STATE, AND LOCAL JURISDICTIONS HAVING AUTHORITY CONTRACTOR SHALL DEMOLISH EXISTING GWB AND METAL STUD FRAMING IN ITS ENTIRETY FOR NEW TENANT STOREFRONT NOTES: 1. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. WALL TYPES SHALL EXTEND UP TO BOTTOM OF SUSPENDED CEILING TILES UNLESS NOTED OTHERWISE IN WALL TYPES. • 3. EXISTING WALLS ADJACENT TO TENANT SPACE SHALL REMAIN- LEAVING MN. 6" GAP AT TOP OF WALL FOR PROPER PLENUM AIR FROM FINISH WALL PER FINISH.SCHEDULE. 4. DATA /ELECTRICAL ARE SI40UN FOR REFERENCE ONLY. ELECTRICAL DESIGN SHALL BE SUBMITTED BY CONTRACTOR AND PERMITTED UNDER SEPARATE PERMIT. 5. ALL MATERIALS SHALL BE NON - COMBUSTIBLE AND /OR SHALL COMPLY WITH THE REQUIRED FLAME SPREAD OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION. ALSO ANY WOOD COMPONENTS USED SHALL BE FIRE RETARDENT TREATED WOOD. (IBC 402.15.4, 602, 603, 4 2604) 6. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AS WELL AS LEASE LINE6 J PRIOR TO COINSTRJCTIOTI A%lY tESCREPENCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFIELD FOR CLARIFICATION. 1. CONTRACTOR SHALL PROTECT MALL.' COMMON AREA AT ALL TIMES AND NO CONSTRUCTION MATERIAL, DEBRIS, WORK, OR DUST SHALL ENTER OR BE WITHIN MALL COMMON AREA. D REVIEWED FOR CODE COMPLIANCE PPROVED OCT 2 7 2009 City of Tukwila BUILDING DIVISION WALL TYPES WALL TYPE 1 (NON- RATED) - 5/8" TYPE X GWB - 3 D" STL. FRAMING AT 16" 0.C. - 5 /S" TYPE X GUS 2 WALL TYPE 2 (1 -HR RATED) UL DESIGN + U -465 - EXISTING 5/8" TYPE X GUS - EXISTING 6" STL. FRAMING AT 16" O.C. - EXISTING 5/8" TYPE X GWB - WALL SHALL CONTINUE UP TO STRUCTURE WI GWB STOPPING 6" FROM STRUCTURE NOTE WALL TYPE +2 - CONTRACTOR SHALL VERIFY THE STATUS OF GWB WITHIN TENANT SPACE TO MEET MEET I -HR RATED ASSEMBLY REQUIREMENT. 3 WALL TYPE 1 (NON- RATED) 0 - 3 " STL. FRAMING AT 16" D.C. - 5/8" TYPE X GWB 4 WALL TYPE 2 (1 -HR RATED) UL DESIGN • U -465 - EXISTING 5/8" TYPE X GUS - EXISTING 6" STL. FRAMING AT 16" OTC. - EXISTING 5/8" TYPE X GWB - WALL SHALL CONTINUE UP TO STRUCTURE WI GUS STOPPING 6" FROM STRUCTURE NOTE WALL TYPE +2 - CONTRACTOR SHALL VERIFY THE STATUS OF GUS WITHIN TENANT SPACE TO MEET MEET 1 -HR RATED ASSEMBLY REQUIREMENT. RECEIVEr OCT 12 2009 PERMIT CENTt ISSUE ISSUE DATE: 633 Sacthcenter P nicway Yhkwt4 WA.. 98188 -2668 206 -246-0423 I- - z 0 w w F- z z z w F- WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAVANG IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRWUCRON CARRIES THE ARCHITECTS NAME. ALL DESIGN AND OTHER INFORMATION THOeN ON THE CRANING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional limited Liability Company 4000 DELRIDGE WAY SW MILLS 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 (: co w w U < 0J PERMIT SET OCT. 8, 2009 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ FLOOR PLAN RCP AND SECTIONS A1.0 SMSA #0923 WESTFIELD MALL AT SOUTHCENTER 3 " = 1' - 0" METAL STUD mr, GtU13 !BULKHEAD ALUMINUM STOREFRONT ( DOOR JAMB DETAIL 4 ) MALL BULKH 13' -6" AFF (E) WALL AT MALL PAINTED FIRST LEVEL 'BACKER ROD AND K EACH SIDE ALUMINUM GLASS FRAME 1/2" METAL PANEL INFILL DOOR HEAD DETAIL ALUMINUM THRESHOLD EXISTING TILE - COMPLETE GROUT TO THRESHOLD EAST ELEVATION GWB BULKHEAD FOR TENANT SIGN HEAD DETAIL 3 " = 1' -0" � SILL DETAIL 3" 1 0 z --- COMMON MALL BULKHEAD (E) CEILING BEYOND ALUMINUM FRAME GLASS STOREFRONT METAL STUD AND GUS BULKHEAD ALUMINUM GLASS FRAME 1/2" GLASS EXISTING TILE - COMPLETE GROUT TO SILL AN APPROVED GLAZING CLIP OR GLAZING SUPPORT DEVICE SHALL BE INSTALLED WHERE ONE OR MORE SIDES OF ANY PANE OF GLASS ARE NOT FIRMLY SUPPORTED. CLIPS SHALL RESIST A FORCE OF 50 POUNDS PER LINIER FOOT APPLIED HORIZONTALLY TO ONE PANEL AT ANY POINT UP TO 42 INCHES ABOVE THE WALKING SURFACE. (IBC SECTION 2403) MALL BUL 13' -6" AFF MALL BULKHEAD ALUM. STOREFRONT FRAME GLASS STOREFRONT 3 42.0 NORTH ELEVATION 1/4" = 1' -0" 1/2" GLAZING ALUMINUM STOREFRONT FRAME AT VERTICAL TRANSOM 1/2" GLAZING VERTICAL MULLION DETAIL 3" = 1' -0" METAL STUD AND GW3 BULKHEAD 1/2' GLASS (E) BACK OF HOUSE CORRIDOR (E) DOOR TO REMAIN BUTT GLAZING DETAIL 3" = 1' -0" SEE WALL TYPE »I GAP - MAXIMUM 1/2" GLASS ( //::i:i:i// - 5/8" GUS METAL STUD JAMS HOLLOW METAL FRAME AND ANCHORAGE DOOR JAMB DETIAL H.M. GLAZING HORIZONTAL MULLION DETAIL 3" = 1' -0" 5/8" MB METAL STUD HEADER HOLLOW METAL FRAME AND ANCHORAGE DOOR HEAD DETAIL 1 1/2" = 1' -0" A (FLUSH) WOOD FRAME TYPES DOOR TYPES FRAME AND DOOR TYPES 1/4" = 1' -0" )4" METAL PANEL INFILL ALUMINUM STOREFRONT FRAME B GLASS PANEL DOORS 1)01%. 7 • REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 7 1UU9 City of Tukwila BUILDING DIvncinM REOP '''" (OCT 12 ?Ili h p RM WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED YATHOUT THE ARCHITECT'S PERMISSION AND UNLESS TTIE REPRODUCTION CARRIES THE ARCHITECT'S NAME ALL DESIGN MID OTHER NFORMANON SHOWN ON THE DRAWING ARE OTHERYASE 'M HOUT WRITTEN PROJECT " FROM SE RCHITEC S.M. STEMPER ARCHITECTS A Professional limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 - 2777 • FAX (206) 624 -2973 ISSUE ISSUE DATE: REGISTERED ITECT F-- z w 2 w 0 0 2 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ OC oo w o0 I— Z0) w U <C I— D Q 0 -J r � PERMIT SET OCT. 8, 2009 STOREFRONT ELEVATION AND DETAILS A2.0 SMSA #0923,01 WESTFIELD MALL AT SOUTHCENTER TENANANT SEE SC1-1E10. INFILL . A W :..: .: METAL PANEL I METAL INFILL PANEL I \ / \ iNTRY z (ID ;Wa 8 A2.0 FF 1 \V 3 " = 1' - 0" METAL STUD mr, GtU13 !BULKHEAD ALUMINUM STOREFRONT ( DOOR JAMB DETAIL 4 ) MALL BULKH 13' -6" AFF (E) WALL AT MALL PAINTED FIRST LEVEL 'BACKER ROD AND K EACH SIDE ALUMINUM GLASS FRAME 1/2" METAL PANEL INFILL DOOR HEAD DETAIL ALUMINUM THRESHOLD EXISTING TILE - COMPLETE GROUT TO THRESHOLD EAST ELEVATION GWB BULKHEAD FOR TENANT SIGN HEAD DETAIL 3 " = 1' -0" � SILL DETAIL 3" 1 0 z --- COMMON MALL BULKHEAD (E) CEILING BEYOND ALUMINUM FRAME GLASS STOREFRONT METAL STUD AND GUS BULKHEAD ALUMINUM GLASS FRAME 1/2" GLASS EXISTING TILE - COMPLETE GROUT TO SILL AN APPROVED GLAZING CLIP OR GLAZING SUPPORT DEVICE SHALL BE INSTALLED WHERE ONE OR MORE SIDES OF ANY PANE OF GLASS ARE NOT FIRMLY SUPPORTED. CLIPS SHALL RESIST A FORCE OF 50 POUNDS PER LINIER FOOT APPLIED HORIZONTALLY TO ONE PANEL AT ANY POINT UP TO 42 INCHES ABOVE THE WALKING SURFACE. (IBC SECTION 2403) MALL BUL 13' -6" AFF MALL BULKHEAD ALUM. STOREFRONT FRAME GLASS STOREFRONT 3 42.0 NORTH ELEVATION 1/4" = 1' -0" 1/2" GLAZING ALUMINUM STOREFRONT FRAME AT VERTICAL TRANSOM 1/2" GLAZING VERTICAL MULLION DETAIL 3" = 1' -0" METAL STUD AND GW3 BULKHEAD 1/2' GLASS (E) BACK OF HOUSE CORRIDOR (E) DOOR TO REMAIN BUTT GLAZING DETAIL 3" = 1' -0" SEE WALL TYPE »I GAP - MAXIMUM 1/2" GLASS ( //::i:i:i// - 5/8" GUS METAL STUD JAMS HOLLOW METAL FRAME AND ANCHORAGE DOOR JAMB DETIAL H.M. GLAZING HORIZONTAL MULLION DETAIL 3" = 1' -0" 5/8" MB METAL STUD HEADER HOLLOW METAL FRAME AND ANCHORAGE DOOR HEAD DETAIL 1 1/2" = 1' -0" A (FLUSH) WOOD FRAME TYPES DOOR TYPES FRAME AND DOOR TYPES 1/4" = 1' -0" )4" METAL PANEL INFILL ALUMINUM STOREFRONT FRAME B GLASS PANEL DOORS 1)01%. 7 • REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 7 1UU9 City of Tukwila BUILDING DIvncinM REOP '''" (OCT 12 ?Ili h p RM WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED YATHOUT THE ARCHITECT'S PERMISSION AND UNLESS TTIE REPRODUCTION CARRIES THE ARCHITECT'S NAME ALL DESIGN MID OTHER NFORMANON SHOWN ON THE DRAWING ARE OTHERYASE 'M HOUT WRITTEN PROJECT " FROM SE RCHITEC S.M. STEMPER ARCHITECTS A Professional limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 - 2777 • FAX (206) 624 -2973 ISSUE ISSUE DATE: REGISTERED ITECT F-- z w 2 w 0 0 2 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ OC oo w o0 I— Z0) w U <C I— D Q 0 -J r � PERMIT SET OCT. 8, 2009 STOREFRONT ELEVATION AND DETAILS A2.0 SMSA #0923,01 WESTFIELD MALL AT SOUTHCENTER TENANANT SEE SC1-1E10.