Loading...
HomeMy WebLinkAboutPermit D09-226 - PANATTONI CONSTRUCTION - TENANT IMPROVEMENTPANATTONI CONSTRUCTION 6840 FORT DENT WY, STE 301 D09 -226 Parcel No.: 2954900425 Address: 6840 FORT DENT WY TUKW Suite No: Tenant: Name: PANATTONI CONSTRUCTION Address: 6840 FORT DENT WY SUITE 301 , TUKWILA WA Owner: Name: PEPPERWOOD HOLDINGS LLC Address: 2835 82ND AVE SE #300 , MERCER ISLAND WA 98040 Phone: Contact Person: Name: LISA BOLSTER Address: 2221 5 AV , SEATTLE WA 98121 Phone: 206 441 -1449 Contractor: Name: PANATTONI CONSTRUCTION INC Address: 8775 FOLSOM BL SUITE 100 , SACRAMENTO CA 95826 Phone: 916- 340 -2400 Contractor License No: PANATCI984NR doc: IBC -10/06 CitIlbf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.citukwila.wa.us DEVELOPMENT PERMIT * * continued on next page ** Permit Number: D09 -226 Issue Date: 11/06/2009 Permit Expires On: 05/05/2010 Expiration Date: 08/19/2010 DESCRIPTION OF WORK: TENANT IMPROVEMENT TO PART OF THE THIRD FLOOR FOR OFFICE USE TO INCLUDE CONSTRUCTION OF NEW PARTITIONS, DOOR, RELITE, AND CASEWORK. Value of Construction: $7,500.00 Fees Collected: $382.68 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0008 D09 -226 Printed: 11 -06 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie The granting of this permit does not pre construction or the p f ance of work. Signature: Print Name: doc: IBC -10/06 City St Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Volumes: Cut 0 c.y. Start Time: End Time: Private: Profit: N Private: Permit Number: Issue Date: Permit Expires On: Size (Inches): 0 End Time: Fill 0 c.y. Public: Non - Profit: N Public: Date: Mit L c D09 -226 11/06/2009 05/0S/2010 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit. Date: 11 110 10 e l This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -226 Printed: 11 -06 -2009 Parcel No.: 2954900425 Address: Suite No: Tenant: 6840 FORT DENT WY TUICW PANATTONI CONSTRUCTION 1: ** *BUILDING DEPARTMENT CONDTITONS * ** 13: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D09 -226 ISSUED 10/21/2009 11/06/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) D09 -226 Printed: 11 -06 -2009 doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1)(It appears on the plans that existing exit signage may not be adequate so additional exit signs may need to be installed.) 24: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 25: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) D09 -226 Printed: 11 -06 -2009 doc: Cond -10/06 • S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 26: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished.(It appears on the plans that the existing emergency lighting may not be adequate so additional emergency lighting may need to be installed.) 27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 29: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 30: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 31: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 32: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 33: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 34: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code.,(NFPA 70) 35: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 37: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 38: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 39: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** D09 -226 Printed: 11 -06 -2009 • City of Tukwila I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doc: Cond -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Print Name: -VI T -F ! E ' Date: 1 0 1/ 1 D09 -226 Printed: 11 -06 -2009 Tenant Name: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http../rwwu tulnvila. wa us Name: . i-5f�-" ,3 0 4 - $'T /Q Mailing Address: 2 -Z. 2 / -5 /5 E -Mail Address: • 'O /.578/�.0is. F '.' J C.v P*9r7■4 - •// / i'2 0 7 5 iC 7r- / Contractor Registration Number: PAt t L r4T'e.= 184 t--1. 1Z. H:\ Applications \Forts- Applications On Line \2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh �O. C77 G "./ .� c-01 PJC., .C.0 Cit Fax Number: (Fo Company Name: M A- 12-V i LI S ']- 1 t.-J 4 Mailing Address: 2 22- t S•^1 A E- S7c t t_ C King Co Assessor's Tax No.: Site Address: •We' Fo /e '')' 9 ' Suite Number: p H ^/ 7 - 'e" c 7 a "el New Tenant: office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** State Po Floor: Zip Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. SITE 3 ❑ Yes )4No Property Owners Name: "f /,43G,77 - Mailing Address: 25 31 .92 -4 V .S 3 vo r e „g. City �S G � yJ � / State CONTACT PERSON - who do e contact when your permit is ready to be issued Day Telephone: Za 6 • 5 2 / yy `7 4,./.2 / State / Zip 24'6. Vv. 51 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) 51 4, • s- TueI ), 4- w ' .P/ &- P City State Zip Day Telephone: 2•E: • 8 313 • J - - Fax Number: 24'6. • 8 3 S • 3s 4-1 Expiration Date: ARCHITECT OF RECORD - All plans must be stamped by Architec Record 8l 2.1 City State Contact Person: L-- i '`� '78 1• Day Telephone: x--040 • •--P4 E -Mail Address: L. • b -e 1%1 .C' Number: fo ' Lf L-1 Zip 1 • 1VLI - y 3 (1 ENGINEER OF RECORD -All plans must be wet s amped by Engineer of Record City Day Telephone: Fax Number: Zip Page I of BUILDING PERMIT INFORMATION 206 -431 -3670 Valuation of Project (contractor's bid price): $ 1 ) S O o Existing Building Valuation: $ Scope of Work (please provide detailed information): TE-,J .s. r VI—, F r o v e. fv ,e , - , - } - - Fz 17.w or _ - rl-r— - T - -{ - 1 2.x+ F t�oa t- fo rte— i c.tE_. I..J E - t - c::. t ►.t c.L_ A 3 t.. Co a 5. _ _ o -@ c.J ,et- rt---r t _ �' ao - '"e. l 4-- c.A 5 ��.a a,r tom._. Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Belo PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes H:\Applications\Fomts- Applications On Line \2009 Applications \ I -2009 - Permit Application.doc Revised: I -2009 bh If yes, a separate permit and plan submittal will be required. Compact: Handicap: No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Saf ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System -- For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. ❑ None ❑ Other (specify) Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor 14 /". /..i/� \/— E. Y 2 Floor A . NIA_ Ni .-- L> P ; 3rd 3 d Floor ± /2,41 ,400 3 O (07 fa/..4, al/ . — $ i� Floors thru Basement Accessory Structure* Attached Garage t4 Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION 206 -431 -3670 Valuation of Project (contractor's bid price): $ 1 ) S O o Existing Building Valuation: $ Scope of Work (please provide detailed information): TE-,J .s. r VI—, F r o v e. fv ,e , - , - } - - Fz 17.w or _ - rl-r— - T - -{ - 1 2.x+ F t�oa t- fo rte— i c.tE_. I..J E - t - c::. t ►.t c.L_ A 3 t.. Co a 5. _ _ o -@ c.J ,et- rt---r t _ �' ao - '"e. l 4-- c.A 5 ��.a a,r tom._. Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Belo PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes H:\Applications\Fomts- Applications On Line \2009 Applications \ I -2009 - Permit Application.doc Revised: I -2009 bh If yes, a separate permit and plan submittal will be required. Compact: Handicap: No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Saf ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System -- For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. ❑ None ❑ Other (specify) Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction -- In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O OR AU ' O : E 1 A PJ` NT: Signature: Print Name: _ �tr�� t=, Day Telephone: Z " 441 Hi Mailing Address: 122_ l i Fri* ,Wt 1 — L. City Date Application Accepted: toll)loc\ H:\ Applications \Fortes- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: I -2(109 bh Date Application Expires: 0 to Date: ' v ^Q 7 vc/.4. 962.1 State Zip Staff Initials: Page 6 of 6 Receipt No.: R09 -01760 Initials: User ID: Payee: JEM 1165 ACCOUNT ITEM LIST: Description BART A BRYNESTAD BUILDING - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Payment Check 364 233.70 Authorization No. TRANSACTION LIST: Type Method Descriptio Amount RECEIPT • Parcel No.: 2954900425 Permit Number: D09 -226 Address: 6840 FORT DENT WY TUKW Status: APPROVED Suite No: Applied Date: 10/21/2009 Applicant: PANATTONI CONSTRUCTION Issue Date: Payment Amount: $233.70 Account Code Current Pmts 000.322.100 229.20 640.237.114 4.50 Total: $233.70 Payment Date: 11/06/2009 02:16 PM Balance: $0.00 PAYMENT RECEIVED doc: Receipt -06 Printed: 11 -06 -2009 Parcel No.: 2954900425 Permit Number: D09 -226 Address: 6840 FORT DENT WY TUKW Status: PENDING Suite No: Applied Date: 10/21/2009 Applicant: PANATTONI CONSTRUCTION Issue Date: Receipt No.: R09 - 01644 Initials: JEM Payment Date: 10/21/2009 11:42 AM User ID: 1165 Balance: $233.70 Payee: PDC, INC. - PANATTONI DEVELOPMENT COMPANY, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 013832 148.98 Authorization No. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http.• / /www. ci. tukwila. wa. us RECEIPT a Payment Amount: $148.98 Account Code Current Pmts 000/345.830 148.98 Total: $148.98 PAYMENT RECEIVED doc: Receiot -06 Printed: 10 -21 -2009 Pro' ct: YA A - T,,,, ,. C-° �',, ype of Inspectio 1 , e tiof: c �` Address :. �7S6' o r f D ate Called: S pec i a Instructions: ci r C•' 'D OAJ Date Wanted: a.m. .. Q m Requester: Phone No: 1-4) Co - 3 q i70 q INSPECTION RECORD Retain a copy with permit -22 INS E ION NO. PERalT NO. CITY OF TUKWILA BUILDING DIVISION 12 -- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Inspe or: Date: /( fd El $60.00 REINSPECTION FEE REQUIRED. Prioito inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: ,,_ l/9/14 ,'9,✓ a,V.1 (rD Type of Inspection: / 6 L 42 .71/6 Address: 6 8y0 (ogr e wy Date Called: Special Instructions: Date Wanted: Gam- /O,�O ,'m. tP. Requester: Phone No: x2. - cG- ()q 6o< -22 INSPECTION RECORD Retain a copy with permit INSPECT NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 trIM ENTS: 2, a/6 -,q 5 l oP644 l� S ' pw Id N, ,5 - 4 A/A- 1 0.00 REINSPECTION FEE R (WIRED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: Approved per applicable codes. 0Corrections required prior to approval. Project: , A.tV47 T &I / ( r Type of Inspection: a 4' r 4 "PI. n/ G, Address: Date Called: G SyQ .o,7 -04vr Special Instructions: _y+ r 4 t/ 3SC) Date Want %d: 2 Alh / 5 Requester: Phone No: v1 - .3 56 - 7 .' INSPECTION RECORD etain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMI NO. F- (2 06)431 -3670 Date: /Z 0 REINSPECTIO FEE REQUI' r ' riar to inspectio , fee mast be at4300 Southcen er Blvd., S ite 10 Mt to schedule reinspe tion. Re { - pt No.: pproved per applic4ble codes. Corrections required prior to approval. Project: P n04; r 9y -c tys i 4 Type of Inspection: .Cis -c..- T le) 1 Address: 6 $' -1L7 i- ©4- .- t- 1 9 E4 LM Suite #: c Contact Person; /. c el Special Instructions: Phone No.: p G 396. 7'9S- Needs Shift Inspection: ' Sprinklers: ,Fire Alarm: Hood & Duct: Monitor: ; Pre -Fire: Permits: Occupancy Type INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 0o7- 22-4. PERMIT NUMBERS ndover Park East, Tukwila, Wa. 98188 206- 575- 4407 EJg Approved per applicable codes. Fi Corrections required prior to approval. COMMENTS: f; rc, Inspector: Date: 1,/(1,0 Firs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to Schedule a reinspection. ACTIVITY NUMBER: D09-226 DATE: 10 -21 -09 PROJECT NAME: PANATTONI CONSTRUCTION SITE ADDRESS: 6840 FORT DENT WY Original Plan Submittal Response •to in 1 Corr of t ision # After Permit Issued Response I DEPART ENTS: q u (diing Division T PI Pub li c Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUTING: Please Route ❑ REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 aoo aa003 liwad ' PLAN REVIEW /ROUTING SLIP F ir e Preventio t���h Plannin Division 22, Structural Incomplete ❑ Permit Coordinator DUE DATE: 10 -22 -09 Not Applicable INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required ❑ No further Review Required ❑ DATE: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 11 -19-09 DATE: CORRECTION LETTER MAILED: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 TRAVELERS CAS Et STY CO OF AMER 104094785 08/08/2003 Until Ca Cancelled 08/19/2002 1 ST PAUL FIRE Et MARINE INS CO FF400SR961708/08/2002 Until a Cancelled Ca 08/08/2003 $12,000.0008/19 /2002 Name Role Effective Date Expiration Date BOOM, DENNY LEE PRESIDENT 08/19/2002 CHRISTENSON, ROBERT JOHN JR SECRETARY 08/19/2002 LOORZ, RICHARD ERIK VICE PRESIDENT 08/19/2002 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. S Business Owner Information • Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company PANATTONI CONSTRUCTION INC 9163402400 8775 FOLSOM BLVD, SUITE 100 SACRAMENTO CA 958263709 OUT OF STATE Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601928454 ACTIVE PANATCI984NR CONSTRUCTION CONTRACTOR 8/19/2002 8/19/2010 GENERAL UNUSED Bond Information Insurance Information 1 https://fortress.wa.gov/lni/bbip/Detail.aspx Page 1 of 2 11/06/2009 ACT ACOUSTICAL CEILING TILE JT JOINT ADJ ADJACENT / ADJUSTABLE LL @TE BY LANDLORD AT TENANTS EXPENSE AFF ABOVE FINISH FLOOR LF LINEAL FOOT ALT ALTERNATE MAX MAXIMUM ALUM ALUMINUM MECH MECHANICAL APPROX APPROXIMATELY MFR MANUFACTURER AT MIN MINIMUM BLDG BUILDING MISC MISCELLANEOUS BLKG BLOCKING MTD MOUNTED B/S BUILDING STANDARD MTL METAL CAB CABINET MW MICROWAVE OVEN CLR CLEAR/CLEARANCE N NORTH / NEW CLG CEILING N/A NOT APPLICABLE CL CENTERLINE IvIC NOT IN CONTRACT COL COLUMN NO NUMBER COMM COMMUNICATION NOM NOMINAL COMP COMPOSITION NTS NOT TO SCALE CONST CONSTRUCTION OC ON CENTER CONT CONTINUOUS OPNG OPENING PT CARE :OER PP OPPOSITE CT CERAMIC /CONCRETE TILE RIG ORIGINAL DIA DIAMETER M PERMANENT DIM DIMENSION PL PLATE DR DOOR :LID TC MINATE PLYWOOD DWG DRAWING PR PAIR E EXISTING /EAST I PARTITION EA RADIUS /REMOVE /RELOCATE ELEC ELECTRIC EC LR■ EV TI IEW IST IED T EXTERIN /REVSE FINISH ROO ROUGH OPENING FLR FLOOR FLUOR FLUORESCENT S SOUTH FR FIRE RATED SCHED SCHEDULE FT FEET_ SC SOLID CORE STOR STORAGE N � FURN FURNISH / FURNISHINGS SECT SECTION GA GAUGE SIM SIMILAR _ r . GALV GALVANIZED SPEC SPECIFICATION GD GARBAGE DISPOSAL SQ SQUARE GL GLASS /GLAZING STD STANDARD GWB GYPSUM WALL BOARD STL STEEL HDW HARDWARE SUSP SUSPENDED HM HOLLOW METAL TEL TELEPHONE HT HEIGHT TYP TYPICAL HVAC HEATING, VENTILATING, VCT VINYL COMPOSITION TILE AIR CONDITIONING VERT VERTICAL IN INCH W WEST INCL INCLUDE W/ WITH INSUL INSULATION W/O WITHOUT INT INTERIOR WC WALLCOVERING WC WOOD Q Q I I ® K Q Q T 1 1 I I — - L 7/ 7/777/x/ m SITE �' z ® FORT DENT WAY W �1 L � ] 1 c__, 0 � N.LC• } � —IN • , � � -_._. s . Al . . _. T - - � NORir'r 1 ..,_ . ,.._ :_ N.I.. c tit, VICINITY MAP NTS ■ ■ I AREAOFWORKI MIEN= 111111111■11 GREEN RIVER - -- ''- LONGEST COMMON PATH OF TRAVEL , IN SUITE: 70 . AREA OF WORK. 3,067 U.S.F. / % \. I , r ,. FORT DENT 1, ' = r -- , ' 4 - . , .6 . ? / \ w ��r _._ t iipgi - +•$ ° =1 = =1' • 4 2 _ ` f i — � Fo T DENT 3 a X :- Y � Z� °c " ` i ,•'' -'�� t„ . ti -. • '"' Y �; • NO CHANGE TO BUILDING AREA OCCUPANT LOAD CALCULATION • _ NO EXTERIOR WORK 3,067 USF @ 1:100 - • NO CORE / SHELL WORK 31 OCCUPANTS (1) EXIT REQUIRED; (2) EXITS PROVIDED • NO STRUCTURAL WORK • NO CEILING GRID OR SUPPORT WORK s - �� m � : � . � � i_., .- NORIFI _ r _ HORN 1 ABBREVIATIONS NA 2 KEY PLAN EXITING AND OCCUPANCY LOAD CALCULATION 1 /32 " =11 -0 " 4 SITE PLAN NTS PROVIDE 4'41" WIDE ACOUSTIC BAIT INSULATION PER METAL STUDS STAGGERED 8' @ -0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12' -0 ". ATTACH TO STRUCTURE ABOVE W/ HILTI ' POWER DRIVEN FASTENER 3/4" MIN. \ (2) #10 SCREWS CONTINUOUS CEILING GRID - DO NOT SEISMIC BRACING (BEYOND) 1O/TI -1. CUT. tr.— CENTERED OVER PARTITION ABOVE HUNG CEILING AT SOUND AND PARTITIONS. ' � . ' ,," 1/4" NON - COMBUSTABLE. WOOD FILLER UNDER MAIN RUNNERS 1/8" BLACK FOAM HOLD BACK 1/4 tttttlltttllt l\�li[tt•�dltltttlltllllt °= REVEAL (PAINT BLACK) OR MATCH EXISTING. ∎ _ l m i "' SUSPENDED CEILING. 11 TAPE 4 II /' 'lr FR EDGE OF TR , (BOTH S ` 1 0. 21/2" 24" _ 1/8 " BLACK FOAM TAPE HOLD BACK 1/4" FROM EDGE OF ) LINE OF CEILING TILES CONTINUOUS 2 -1/2" x 1 -1/4" 25 G A. METAL BEYOND r- i , TRACK WITH 2 #10 SCREWS AT 24 O.C. O REVEAL BLACK) ) X 25 GA. STL. STUDS @ O.C. :° W/ 5/8" GWB, 'TYPE 'X', EACH SIDE. LINE OF CEILING GRID, CONTINUOUS CEILING GRID u ,, a -' _` s.: =; ( ) (PAINT OR MATCH EXISTING CONDITION. (BOTH SIDES OF PARTITION) 5/8" FIRE RETARDANT PLYWOOD BLOCKING AT WALL HUNG ITEMS ;; C — TRACK. .. C ) SYSTEM - DO NOT CUT.) CONTINUOUS 'L' METAL TRIM W/ PAPER WING (BOTH ) 'F( ( ) . c '"'" ) >, ) ( ) SIDES OF PARTITION) ACOUSTIC GATT INSULATION AT TENANT DEMISING PARTITION : (WHERE APPLICABLE REFER TO DRAWING PLANS) ALTERNATE FOR BLOCKING: C ) C ) 5 NA N 6 NA NA ( C -- 20" WIDE SHEET METAL AT +40" FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING) LATERAL BRACING TENANT WALLS (NO CASEWORK) HEAD SECTION MAX MAX MAX MAX MAX 8' MAX 2' MAX CONTINUOUS 25 GA. METAL RUNNER CHANNEL, ) �, 8' �, 8' �, 8' �, 8' �, 8' ANCHOR TO FLOOR AS ) REQUIRED WITH HILTI ( 1. c POWER DRIVEN FASTENER C j 3/4" MIN. EMBEDMENT AT 24" ( ) O.C. OR SIMILAR. (— LATERAL BRACING PER DETAIL ABOVE (TYP.) NOTES: " 5/8" GWB, TYPE 'X' EACH SIDE ( ) ) . FLOORING AS SCHEDULED ) BASE, AS SCHEDULED. SIDES OF PARTITION) (BOTH C ) (BOTH SIDES OF PARTITION.) ) EXISTING STRUCTURE BASE SECTION 1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FT. LONG. (PER TYP. PART. PLAN) 2. TEMPORARY ATTACHMENT OF PARTITION TOP TRACK TO THE GRID IS PERMITTED TO ALIGN AND SET THE WALL UNTIL PERMANENT BRACING IS PROVIDED. REMOVAL OF THE TEMPORARY HOLDING SCREWS IS UP TO THE DISCRETION OF THE SPECIFIC LOCAL BUILDING OFFICIAL. CONTRACTOR TO VERIFY. 3. PROVIDE BRACING AT ANY PERMANENTLY PARTITION THAT IS NOT ATTACHED TO CEILING GRID. 7 NA_ N 8 NA N A 9 STANDARD TE NANT PARTITION 1-1/2"=1W 10 PARTITION HEAD BRACING DETAIL 11 NA NA 12 NA NA 13 NA NA 14 NA NA r4 U Cr) 3 0 U N _ 0 U rn 0 a c E ` 0 0 0 0 I N CO cn co • CO - ro N (i) Dm E CL •Q N Lo it ) w o ai � a� a3 Qj _ • � a_0P 0Ecnox SCOPE OF WORK TENANT IMPROVEMENT TO PART OF THE THIRD FLOOR FOR OFFICE USE TO INCLUDE CONSTRUCTION OF NEW PARTITIONS, DOORS, RELITES, AND OTHER FEATURES. AREA OF SUITE: 3,067 USF PROJECT ADDRESS: 6840 FORT DENT WAY, TUKWILA, WA 98188 OCCUPANCY TYPE: B, OFFICE CONSTRUCTION TYPE V -B SPRINKLED BUILDING CODE: 2006 INTERNATIONAL BUILDING U DING CODE (IBC) 2006 INTERNATIONAL FIRE CODE (IFC) 2006 INTERNATIONAL PLUMBING CODE (IPC) 2006 INTERNATIONAL MECHANICAL CODE (IMC) 2005 NATIONAL ELECTRICAL CODE ICC /ANSI 117.1 - ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES WASHINGTON STATE ENERGY CODE (WSEC), WAC 51 -11 WASHINGTON INDOOR AIR QUALITY CODE ASSESSOR'S PARCEL #: 295 490 0425 LEGAL DESCRIPTION LOT 1 OF SHORT PLAT NO 79 -7 -55 ACCORDING TO SHORT PLAT SURVEY RECORDED UNDER KING COUNTY RECORDING NO 7908210370. TOGETHER WITH THE FOLLOWING DESCRIBED PORTION OF LOT 2 OF SAID SHORT'LAT, BEGINNING AT THE MOST WESTERLY CORNER OF LOT I OF SHORT PLAT NO 79 -7 -5 ACCORDING CCORDING TO SHORT PLAT SURVEY RECORDED UNDER KING COUNTY RECORDING NO 7908210370, THENCE NORTH 63?3'49" EAST 237.32' TO THE MOST NORTHERNLY CORNER OF SAID LOT 1, THENCE SOUTH 26 ?24'11" EAST 227.32' TO CORNER BETWEEN LOTS 1 AND 2, THENCE NORTH 63 ?35'49" EAST ALONG THE SOUTHEASTERLY LINE OF SAID LOT 2, 252.25', THENCE NORTH 36 ?24'11" WEST 77.65', THENCE NORTH 56 ?15'11" WEST 234.09 ", THENCE NORTH 31 ?12'43" WEST 82.39' TO AN INTERSECTION WITH THE NORTHWESTERLY LINE OF SAID LOT 2, THENCE SOUTH 58 ?47'17" WEST ALONG SAID NORTHWESTERLY LINE 102.77', THENCE SOUTH 55 ?39'53" WEST ALONG SAID LINE 63.16', THENCE SOUTH 48 ?39'58" WEST ALONG SAID LINE 55.63', THENCE SOUTH 39 ?21'15" WEST ALONG SAID LINE 88.24', THENCE SOUTH 30 ?04'58" WEST 85.21' TO THE MOST WESTERLY CORNER OF SAID LOT 2, THENCE SOUTH 37 ?36'40" EAST 20.92' TO THE POINT OF BEGINNING. PROJECT DIRECTORY TENANT PANATTONI DEVELOPMENT BUILDING REPRESENTATIVE J.C. RADOVICH 2835 82ND AVE. SE, STE 300 MERCER ISLAND, WA 98040 CONTACT: REBECCA DAVIDSON TELEPHONE: (206) 267 -6060 FAX:(206) 267 -6061 EMAIL: davidson @hotmail.com DESIGNER MARVIN STEIN AND ASSOCIATES, LLC 2221 FIFTH AVENUE SEATTLE, WASHINGTON 98121 CONTACT: LISA BOLSTER PHONE: (206) 441 -1449 FAX: (206) 441 -4361 EMAIL: Lbolster@marvinstein.com HVAC AND FIRE LIFE SAFETY NOTES HVAC 1. RECONFIGURE AS REQUIRED FOR ALTERATIONS. 2. RE- BALANCE HVAC SYSTEM. 3. CLEAN ALL EXISTING GRILLES. 4. VERIFY AND RELOCATE THERMOSTAT(S) AS NECESSARY. FIRE LIFE SAFETY 1. ALL FIRE EXTINGUISHERS, HORN STROBES, EXIT SIGNS AND SPRINKLER HEADS, ETC. TO BE PER CODE. 2. CONTRACTOR TO UPGRADE AUDIBLE AND VISUAL ALARMS TO CURRENT CODES AS NECESSARY. GENERAL NOTES CONTRACTOR TBD SEPARATE PERMIT REQUIRED FOR: CityofT BUILDING DIVISION 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. 2. CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN CONTRACT DRAWINGS & SPECIFICATIONS FOR BUILDING. 3. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 4. B/S INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD DRAWN AND /OR SPECIFIED IN BUILDING CONTRACT DOCUMENTS. 5. DIMENSIONS TO AND OF ELECTRICAL & TELEPHONE OUTLETS INDICATES MAXIMUM OF 6" FROM CENTERLINE OF ELECTRICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. 6. CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS, UNLESS NOTED OTHERWISE. 7. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED, FOR SEISMIC CONDITIONS, IN BUILDING JURISDICTIONS WHERE APPLICABLE. 8. PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS. 9. CONTRACTOR SHALL ALIGN OR FURR ALL INTERIOR PARTITIONS SO THAT FINISHES REMAIN FLUSH IN ROOMS AND CORRIDORS REGARDLESS OF DIFFERENCES IN PARTITION WIDTHS. 10. PROVIDE LEVELLING THROUGHOUT THE SPACE FOR PROPER INSTALLATION OF EQUIPMENT, PARTITIONS, DOORS, GLUE -DOWN CARPET, ETC, TOLERANCE OF 1/4" IN 10' -0" DIFFERENCE IS ACCEPTABLE. REVIEWED FOR CODE 0 COMPLIANCE SHEET S INDEX V 0 3 2009 TI -2 CONSTRUCTION /ELECTRICAL PLAN / REFLECTED CEILING PLAN City of Tukwila I(Wlia BUILDING VI NG DI RInnl TI -1 COVER SHEET & DETAILS RECEIVED CITY OF TUKWILA OCT 212009 PERMIT CE of ;1111• I . : {1! FILE COPY ft, till.•! . • Marvin Ste '.sociates, LLC planning v design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 NO. FORT DENT II 6840 FORT DENT WAY TUKWILA, WASHINGTON 98188 Plan Approval of co cdon the violation of any adopted code or Re SHEET TITLE: JOB NO.: TENANT: I 69 DRAWN BY: CL, MW CHECKED BY: LB, GG y or Rita BUILDING D REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal f and may include additional plan review fees. a 09048.000 and does not authorize Receipt i ON REVISIONS INDICATED THUS A INITIAL SUBMITTAL FOR APPROVAL GENERAL REVISION GENERAL REVISION von - 2.21e REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2009. DATE 10/14/09 10/15/09 10/19/09 PANATTONI NID 0 DEVELOPMENT THIRD FLOOR COVER SHEET & DETAILS BY LB LB LB TI -1 OF 2 DECK DECK DECK DECK rD tit (GFI) NEW WALL TO :E INSTALLED AT :ND OF EXISTING (T) CASEWORK. COORDINATE WITH ' TENAN . � -1 " 36 6 EQ. 25" CLR. SPACE FOR REF /DW 3/8 " =1' -0" 3 EQ. ELEVATION B/S A.D.A.-APPROVED P -LAM SINK CABINET (NO BOTTOM @ BASE) WITH B/S & A.D.A.-COMPLIANT BAR SINK & FAUCET. v � \ INSULATE WRAP @ EXPOSED SUPPLY & DRAIN LINES WOMEN: 1/8"=1'-0" 5 10' 20' FACE OF GWB B/S 12" DEEP P -LAM UPPER CABS. WITH DOORS AND (2) ADJ. SHELVES, TYP. 25 DEEP P -LAM COUNTERTOP AND BACKSPLASH. B/S 24" DEEP P -LAM LOWER CABS. WITH DOORS, DRAWER, (1)ADJ. SHELF AND 4" TOE KICK, TYP. NOTE: PROVIDE FINISHED ENDS AT ALL EXPOSED ENDS. PROVIDE FILLER FOR UPPER & LOWER CABINET AS NECESSARY 30' MEN:. ELEC. X AREA OF WORK -- - - CONSTRUCTION /ELECTRICAL PLAN ELEV. LOBBY NORTH 6" UNLESS OTHERWISE NOTED HARDWARE a. B/S LOCKSETAND CLOSER. DOOR NUMBER TYPE OF DOOR A. B/S 3-0" WIDE S.C. STAIN GRADE WOOD DOOR IN B/S WOOD FRAME TO MATCH EXISTING CORRIDOR DOORS. HEIGHT TO MATCH EXISTING CORRIDOR DOORS. NO LIGHTING CHANGE NOTES: 1. PROVIDE W.S.B.F. COMPLIANT HARDWARE. ALL HARDWARE TO MATCH B /S. 2. RE -USE EXISTING DOORS SCHEDULED FOR REMOVAL WHEREVER POSSIBLE. DOORS TO BE RE -USED ARE TO BE TOUCHED UP TO BRING INTO "LIKE NEW" CONDITION. 3. THRESHOLDS AT DOORWAYS SHALL BE 1/2" MAX. IN HEIGHT. 4. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 3/4" MINIMUMAND 48" MAXIMUM ABOVE FINISH FLOOR. 5. FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN DOORS, OTHER THAN FIRE DOORS, SHALL BE AS FOLLOWS: 1) INTERIOR HINGED DOOR: 5.0 POUNDS (22.2 N); 2) SLIDING OR FOLDING DOOR: 5.0 POUNDS (22.2 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. L' CONSTRUCTIONLEGEND ELEC / COMMUNICATIONS LEGEND CEILING LEGEND EXISTING BUILDING CORE/COMMON AREAS EXISTING B/S MULTI - TENANT CORRIDOR PARTITION B/S TENANT DEMISING PARTITION. EXISTING B/S TENANT PARTITION TO REMAIN NEW B/S TEMPERED SAFETY GLASS RELITE IN B/S FRAME TO MATCH CORRIDOR. SEE CONSTRUCTION PLAN FOR WIDTH. NEW B/S TENANT INTERIOR DEMISING PARTITION. SEE TI -1. NEW B/S TENANT INTERIOR PARTITION. SEE TI -1. EXISTING CONSTRUCTION TO BE REMOVED ALIGN EXISTING CEILING GRID AND TILES TO REMAIN. EXISTING 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO REMAIN. EXISTING 2'X2' AND 2'X4' RECESSED EMERGENCY FLUORESCENT LIGHT FIXTURES TO REMAIN. EXISTING ILLUMINATED EXIT SIGN TO REMAIN UNO. EXISTING LIGHT SWITCH TO REMAIN. Igc NEW ABOVE COUNTER B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET. (GFI= GROUND FAULT INTERRUPTER) (T) NEW ABOVE COUNTER B/S WALL MOUNTED DEDICATED 120V 20A DUPLEX ELECTRICAL OUTLET. (T = TIMER) x AREA OF WORK - 1/8 " =1' -0 5' 10' CONSTRUCTION NOTES 4. FOR GENERAL NOTES, SEE TI -1. REFLECTED CEILING PLAN 20' 30' Imems 1. DISRUPTION OF BUILDING WATER, ELECTRICAL POWER, FIRE ALARM & SECURITY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES AND BUILDING OWNER/MANAGEMENT. 2. ALL WALL INFILLS TO ALIGN WITH ADJACENT SURFACES ON EACH SIDE. 3. CONTRACTOR TO PROVIDE AND INSTALL BLOCKING FOR ALL DOORS, ACCESSORIES AND CABINETRY, IF REQUIRED. CONSTRUCTION KEYNOTES O REMOVE EXIT SIGN. ELEV. LOBBY 1 NORTH City of Tukwila BUILDING DIVIsinT CRY � TU KVN LA OCT 212009 PERMIT CE R REVIEWED FOR CODE COMPLIANCE APPROVED Era v 0 3 2009 FORT DENT II 6840 FORT DENT WAY TUKWILA, WASHINGTON 98188 Marvin Ste planning sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: LB CHECKED BY: LB, GG NO. INITIAL SUBMITTAL FOR APPROVAL GENERAL REVISION JOB NO.: 09048.000 REVISIONS INDICATED THUS A GENERAL REVISION TENANT: SHEET TITLE: REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2009. DATE 10/14/09 10/15/09 10/20/09 BY LB LB LB PANATTONI DEVELOPMENT THIRD FLOOR CONSTRUCTION /ELECTRICAL PLAN AND REFLECTED CEILING PLAN TI -2 OF 2